CNS Notification 10295020
ML061980096
Person / Time
Site: Cooper 
Issue date: 02/18/2004
From: Stask M
Nebraska Public Power District (NPPD)
To:
Office of Nuclear Reactor Regulation
References
FOIA/PA-2006-0007, R4-5A29
Download: ML061980096 (5)


Text

U41I IOI 1UU I imlrrlJ I.ULIIIolaUaio UVeIVIeW i

Notification:

10295020 Notfichtion 10295020 Description SW PUMP D LOW BRG WATER Reported by MJSTASK 03:05:1 Start date 02/11/2004 Start time

03. :05:18

,Priority CM FunctLocation SORT Equipment Order Assembly MaintPlanGroup CAP CAP/N' Mayf. Start Date Mayf. Start time 00:00:00

. V ~ S t' 7 ALARM 8

Notification ty7 NotifictnDate End date End timne pe CR K

Condition Report 02/11/2004 02/17/2004

.16 :30:0.0 e

00:00:00 AUT Tel.

Malf. End date Maif. End.time

UZIntIZUUO,.

IIPU:. Notitication overview 1 SL;*S;HVWI.

Uopy 4

Page Z Notification:

10295020 02/11/2004 03:05:18 btcuser (BTCUSER)

DESCRIPTION OF CONDITION:

SW PUMP D LOW BRG WATER ALARM WAS RECIEVED AFTER SECURING D SW PUMP.

GLAND WATER FLOWS AND PRESSURES WERE NORMAL WHEN CHECKED SEVERAL MINUTES AFTER THE ALARM HAD COME IN AND CLEARED.

ALARM SHOULD NOT HAVE COME IN REQUIREMENT NOT MET:

ALARM ON LOW BEARING FLOW WHEN SECURING PUMP METHOD OF DISCOVERY:

CONTROL ROOM ALARM IMMEDIATE ACTIONS TAKEN:

CHECKED GLAND WATER FLOW AND PRESSURE-NO OTHER ACTION REQUIRED-ALARM CLEARED ON IT'S OWN AFTER SEVERAL SECONDS RECOMMENDATIONS:

INVESTIGATE AND OR TREND PROBLEM LOCATION OF EVIDENCE:

SW PUMP ROOM FUNCTIONAL LOCATION (IF KNOWN):

CNS-SW-P"-D EQUIPMENT (IF KNOWN):

REPORTED BY:

MJSTASK WORK CENTER:

OPSCREW SUBMITTED BY:

mjstask SUPERVISOR:

BCROW DEFICIENCY TAG:

NONE

UZI1tIZUU4 NlPPLI: Notitication overview I

.SCSClHWI Copy 4

Page 3 Notification: 10295020 IS THIS AN EQUIPMENT ISSUE?

[X]

YES, CONTACT THE SENIOR REACTOR OPERATOR (SRO)

IN'THE WORK CONTROL CENTER (WCC)

OR THE CONTROL ROOM.

U ]NO IF THE CONDITION IS EXPECTED TO BE INCLUDED IN THE CORRECTIVE ACTION PROGRAM, INDICATE IF YOU WOULD LIKE TO EVALUATE THE ACTIONS TO BE TAKEN FOR THE CONDITION?

[ )

YES

[X)

NO ADDITIONAL COMMENTS:

02/11/2004 10:15:20 Jerry. J.

Long (JJLONG)

SW PUMP. 'D' IS OPERABLE.

Task ACTIVITY TAGD NONE Partner System Status TSCO Task REVIEW OPRV Partner System Status TSCO 02/11/2004 08;:37:23 Peter J.

Donahue (PJDONAH)

OPERATIONS REVIEW OF NOTIFICATION Is the condition an immediate nuclear or personnel safety concern?

[

]

YES -

Immediately notify Shift Manager X

X NO Is the condition reportable or-potentially reportable per 10CFR20, I0CFR26.73, 10CFR50.72, 10CFR50.73, or I1OCFR73.71 (reference Procedure 2.0.5 and NUREG 1022).?

[

I YES - Immediately notify Shift Manager

[X)

NO Does the condition affect or potentially affect any of "the SSC(s) described in Attachment 4? Also consider generic concerns and common mode

'failures, when applicable.

For :significant programmatic issues, determine if a basis for Reasonable Assurance of: Safety per Procedure 0.5.BCO is required.

X I YES -

Immediately.notify.shift Manager

[I NO.-

NOT IN SCOPE OPERABILITY*VERIFICATION

L-VU/V]t;;J' I

IuLEEILVaLupu+ UVIV W

IrdU Notification: 10295020 Does the condition call the,SSC(s) performance into question?

[ X ]

NO-Basis: Alarm cleared. Flow before and after the alarm was check and determined to be adequate. Alarm could have been the result of a pressure spike from securing a pump.

[

]

YES - Declare SSC(s) inoperable and document a basis for Reasonable Assurance of Safety if TRM oriODAM LCO 3.0.3 is entered

]

YES - Document a reasonable *expectation of OPERABILITY on the Notification AND Perform INFORMATION GATHERING Does the condition call the SSC(s) qualification into question?

[ X J NO - Basis: See performance answer.

[

I YES - Declare SSC(s) inoperable and document a basis for Reasonable Assurance of Safety if TRM or ODAM LCO 3.0.3 is entered

[

]

YES - Document a reasonable expectation of OPERABILITY on the Notification AND Perform INFORMATION GATHERING Does the condition describe.an existing but previously unanalyzed condition or accident?

[X)

NO

[

]

YEs -

Declare SSC(s)inoperable and document a basis for Reasonable Assurance of Safety if TRM or.ODAM LCO 3.0.3 is entered YES Document a reasonable expectation of OPERABILITY on the Notification AND Perform INFORMATION GATHERING Task REVIEW WCCR CONCUR WITH OPS REVIEW

'Partner Systein Status, TSCO Task REVIEW CAP WI -

EQUIP TREND Partner System Status TSCO 02/11/2004 09:04:13 Ronnie Deatz (RCDEATZ)

WI -

EQUIP TREND Task REVIEW SCRN TREND Partner System ýStatus TSCO Task REVIEW LIC NOT REPORTABLE Partner Syste*n Status TsCO 02/17/2004 13.:43:11 Coy L. Blair (CLBLAIR)

OPERABLE

.r

  • U *E1 6t~fl4*

ISIflA~

=

rifl~.

n in,.

U -... US a

ran...

'J0.I4=I M

".*L1I=

IJI l

I IMUIMII Notification: 10295020

  • V*Vll
  • W
  • l, 7

-U-Partner System Status Task Partner System Status Item detail Text Object parz Damage Cause of damage Cause text

.REVIEW MRUL EXPORTCIC=SW-FIS-361D TSCO TSSC ACTIVITY.TAGR NONE TSCO 0001 MO00 DISC METH N/A SW, PUMP Assembly Error class End of report