ML061800375

From kanterella
Jump to navigation Jump to search
Draft - SRO Written Exam (Folder 2)
ML061800375
Person / Time
Site: FitzPatrick 
Issue date: 06/01/2006
From: Conte R
Operations Branch I
To: Ted Sullivan
Entergy Nuclear Northeast
Sykes, Marvin D.
References
50-333/06-301 50-333/06-301
Download: ML061800375 (60)


Text

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 1 Examination Outline Cross-reference:

Level SRO Partial or Complete Loss of AC / 6 Ability to determine and/or interpret the Group #

I Tier #

I WA # 295003 AA2.04 following as they apply to PARTIAL OR COMPLETE LOSS OF A.C. POWER:

(CFR: 41.101 43.5 /45.13) 0 System lineups Importance Rating 3.7 Proposed Question:

The plant is at 100% power with the following conditions:

- FW pumps are in 3-element control on the Master Feedwater Controller.

- 125 VDC Station Battery B is on equalize charge per OP-43Al 125

- UPS M-G set is on the DC Drive to "run-in" the DC motor brushes

- EDG B and D are running unloaded per ST-9R, EDG System Quick-VDC Power System.

under load per OP-46B, 120 VAC Power System.

Start Operability Test and Offsite Circuit Verification.

Subsequently, the following valid annunciator alarm:

09-8-4-18, L26 600 V SUPP FDR BKR 12602 TRIP All plant equipment responds per design.

Which ONE of the following is the prompt action the CRS should direct as a result of these plant conditions?

Take manual control of one FW pump on the MSC per AOP-21, Loss of UPS.

Lock the RWR Scoop Tubes to prevent a run back per AOP-21, Loss of Reduce Station Battery B loads per AOP-IgB, Loss of Switchgear L26.

Shutdown EDG B and D per AOP-IgB, Loss of Switchgear L26.

d) Shutdown EDG B and D per AOP-ISB, Loss of Switchgear L26.

Power is lost to L26 resulting in a loss of ESW pump B which supplies cooling water to the EDGs that were running. The UPS is still powered by the A DC battery system and the actions provided in the distracters A & B are not a prompt action to be taken for the plant conditions provided in the stem. Reducing DC loads is a subsequent action per a) b, UPS.

c) d)

Proposed Answer:

Explanation (Optional):

Justification:

AOP-1 9 B.

QUESTION # 1 Continued 1 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet Distracters:

a) Take manual control of one FW pump on the MSC per AOP-21, LOSS Of UPS is incorrect:: Take manual control of one FW pump on the MSC Comments:

Technical Proposed Plant Event 41987, JAF-CR-2005-3818, Momentary loss of UPS results in a RX Scram was used in part to supply the distracters for this question.

per AOP-21, Loss of UPS. This action is part of the response to a momentary loss of the UPS, per the plant conditions provided in the stem, the UPS is still powered from the DC drive. When a subsequent step is taken to transfer the UPS to the altemateAC source, this would be Dart of the actions to take.

I c)

Ref ere nce( s) :

Lock the RWR Scoop Tubes to prevent a run back per AOP-21, Loss of UPS is incorrect:: Lock the RWR Scoop Tubes to prevent a run back per AOP-21, Loss of UPS. Per the stem, the UPS is still powered from the DC Drive and has not lost power.

Reduce Station Battery B loads per AOP-ISB, Loss of Switchgear L26 is incorrect: This is a subsequent action to the conditions provided in the stem.

r

- 1 AOP-~SB, AOP-21.

(Attach if not previously provided) references to be provided to applicants during examination: NONE Learning Objective:

SDLP-71 E EO-1.09.C (As available)

Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during 2 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 2 Examination Outline Cross-reference:

Partial or Total Loss of DC Pwr / 6 Ability to determine and/or interpret the following as they apply to PARTIAL OR COMPLETE LOSS OF D.C. POWER:

(CFR: 41.10/ 43.5 /45.13) 0 Extent of partial or complete loss of D.C. power Proposed Question:

a) b)

c) d)

Proposed Answer:

Level Tier #

Group #

KIA # 295004 Importance Rating SRO 1

1 AA2.02 3.9 The plant is at 100% power.

Feedwater Pump A & B are in 3 element control selected to RX WTR LVLCOLUMN A.

There are Time 0:

- Annunciator 09-8-1-21, 125VDC BATT CHGR A DC GRD

- 125VDC Bus A GND DET meter on Panel 09-8 indicates +25 volts and Time 0 I+

1 minute):

- Annunciator 09-8-1-22, 125VDC BATT CHGR Time 0 (+ 4 minutes):

- Annunciator 09-8-1-23, 125VDC BATT

- 125VDC Bus 119VDC Which QNJ of the following identifies the resultant equipment status AND procedure to respond to the above indications and alarms?

AC POWER breaker at 71 BC-1A 125V DC BATTERY CHARGER A tripped, AOP-45, Loss of DC Power System A 71 BC-I B 125V DC BATTERY CHARGER 262-OAI, AOP-46, Loss of DC Power System RX WTR LVL 06LI-94B indicates downscale, AOP-41, Feedwater Malfunction (Rising Feedwater Flow-High RPV Level)

RHR initiation logic is inoperable, AOP-22, DC Power System A Ground isolation evolutions in progress when the following are noted:

steady AC SUPP TROUBLE VOLT LO Output Voltage meter on Panel 09-8 indicates breaker tripped at 71 MCC-b) 71 BC-IB 125V DC BATTERY CHARGER B breaker tripped at 71 MCC-262-OAI, AOP-46, Loss of DC Power System B Explanation (Optional):

Justification: See ARP-09-8-1-22 causes & step 2, 2nd bullet, AOP-

46. Loss of DC Power System B see symptom A-first bullets first dash- 09-8-1-22 is listedas 1 or more of the following annunciators in alarm.

3 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 2 Continued Distracters:

a) AC POWER breaker at 71BC-1A 125V DC BATTERY CHARGER A tripped is incorrect there is only a small ground on DC Bus A see ARP-09-8-1-21 this also means AOP-45, Loss of DC Power System A is an incorrect procedure to enter.

c) RX WTR LVL 06Ll-94B indicates downscale is incorrect battery is supplying the bus at 119 VDC while this is a symptom of AOP-46, Loss of DC Power B, the voltage is still acceptable for the indicator to be normal. Conditions would NOT require entry into AOP-41, Feedwater Malfunction (Rising Feedwater Flow-High RPV Level) as the stem stipulates WTR Column "A" is selected.

d) RHR B initiation logic is unaffected by the loss of B DC. RHR A logic is powered by B DC.

Technical Reference(s):

AOP-46, AOP-41 AOP-45, (Attach if not previously provided)

AOP-22, OP-46B 09-8-1-19, 09-8-1-21, ARPs:

09-8-1 -22, 09-8-1-23, Proposed references to be provided to applicants during examination:

Learning Objective:

SDLP-71 B EO-1.IO.A.I (As available)

NONE Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

4 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 3 Examination Outline Cross-reference:

Main Turbine Generator Trip / 3 Knowledge of EOP terms and definitions.

(CFR: 41.10/ 43.5 145.13)

Level Tier #

Group ##

KIA # 295005 Importance Rating SRO 1

1 G 2.4.17 3.8 Proposed Question:

The plant is at 100% power.

I&C is working on 06LT-52C, Reactor Water Level Feedwater Control Level Transmitter when the following indications are noted on Panel 09-5:

- RX WTR LVL HI CHNL A Amber Light is ON,

- RX VVTR LVL HI CHNL B Amber Light is ON,

- RX VVTR LVL HI CHNL C Amber Light is ON.

An automatic action occurs due to these indications. The CRS directs insertion of a manual scram and the SNO reports all rods in with the exception that:

3 rods are at position 02 1 rod is at position 48.

The CRS initially directs entry into AOP-1 (Reactor Scram) and EOP-2 (RPV Control).

The automatic action that occurred is the should direct actions in conditions without boron.

a> Main Turbine, EOP-2 (RPV Control) because the reactor WILL b) HPCl Pump, EOP-2 (RPV Control) because the reactor WILL Main Turbine, EOP-3 (Failure to Scram) because the reactor will NOT d)

HPCl Pump, EOP-3 (Failure to Scram) because the reactor will NOT a) Main Turbine, EOP-2 (RPV Control) because the reactor WILL Justification: Indications are directly part of Main Turbine & FW Pump trip circuitry. Per EP-1, EOP Entry and Use, section 4.7.2, the reactor will remain shutdown under all conditions without boron with one rod at 48 if all other rods are at 02 (or inserted).

trips and the CRS remain shutdown under all Proposed Answer:

Explanation (Optional):

5 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 3 CONTINUED Distracters:

b) HPCl Pump trip, EOP-2 (RPV Control) because the reactor WILL Justification: Indications are NOT part of HPCl trip circuitry. The second part of the distractor is correct..

c) Main Turbine Generator trip, EOP-3 (Failure to Scram) because the Justification: The first part is correct but the reactor will remain shutdown.

d) HPCl Pump trip, EOP-3 (Failure to Scram) because the reactor will NOT Justification: The first part is incorrect, the second part is correct.

reactor will NOT Technical Reference(s):

EOP-2, EOP-3, EP-1 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

EOP 2 and 3 Learning Objective:

MIT-301.11A EO-1.04.i (As available)

Question Source:

Bank ##

Modified Bank #

New X

(Note changes or attach parent)

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

6 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION ## 4 Examination Outline Cross-reference:

Refueling Acc / 8 Ability to apply technical

.,=,...... specifications

,..,......,?.....

for a system. (1 OCFR 55.43.Uj@.n)

Level Tier #

Group #

WA # 295023 Importance Rating SRO 1

1 G 2.1.12 4.0 Proposed Question:

The plant has been shutdown for 2 days and is being refueled.

An irradiated fuel bundle is being moved from the core to the spent fuel storage pool. The bundle is over the core and being moved towards the fuel pool when level drops to 22 feet above the RPV flange and then continues to slowly decrease.

The Technical Specification bases for maintaining a minimum water level over the flange is to insure With this lowering level a radiological emergency is declared per RAP-7.1.04B, Refueling Procedure. The Refuel Bridge SRO may then direct the bundle be placed in a ~ l y empty location in the

- RHR Shutdown Cooling can maintain Time to Boil limitations

- core or the Fuel Pool storage rack

- RHR Shutdown Cooling can maintain Time to Boil limitations

- Fuel Pool storage rack only

- iodine release from the design refueling accident is retained by the water and off site doses are maintained within limits,

- core or the Fuel Pool storage rack

- iodine release from the design refueling accident is retained by the water and off site doses are maintained within limits,

- Fuel Pool storage rack only a) b, c) d)

Proposed Answer:

d) the water and off site doses are maintained within limits,

- Fuel Pool storage rack only Justification: In RAP 7.1.048, section 7.3, the procedure allows, if a radiological emergency exists, for the bundle to be placed in an empty spent fuel rack location. Without this emergency, the bundle, if it can not be placed in its target location shall be returned to its prior I ocation.

- iodine release from the design refueling accident is retained by Explanation (Optional):

7 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 4 Continued Distracters:

a) RHR Shutdown Cooling can maintain Time to Boil limitations core or the Fuel Pool storage rack b) RHR Shutdown Cooling can maintain Time to Boil limitations Fuel Pool storage rack only c ) iodine release from the design refueling accident is retained by the water and off site doses are maintained within limits, core or the Fuel Pool storage rack Justification for incorrect answers:

The incorrect portion of the distracters are RHR Shutdown Cooling can maintain Time to Boil limitations and the allowance to be able to store the fuel in any core location.

The level over the flange affects the ability of the water to adsorb heat and the time to boil (plausible distractor). However, the actual reason for the level is for iodine releases.

The fuel is allowed to be stored back into the core per RAP 7.1.048 but it must be returned to its prior location, not ANY location in the core.

Technical Reference(s):

AOP-53, RAP-7.1.04.Bl (Attach if not previously provided)

TS Bases 3.9.6

~~

~

Proposed references to be provided to applicants during examination:

Learning Objective:

SDLP-08B EO-1.17.a (As available)

NONE Question Source:

Bank #

Modified Bank #

New X

(Note changes or attach parent)

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 55.41 10 CFR Part 55 Content:

8 of 60 Rev2

ES-401 Sample Written Examination Form ES-40 1-5 Question Worksheet QUESTION # 4 Continued 55.43 2

2 -Facility operating limitations in the technical specifications and their bases.

normal and abnormal situations, including maintenance activities and various contamination conditions.

6 -Procedures and limitations involved in initial core loading, alterations in core configuration, control rod programming and determination of various internal and external effects on core reactivity.

7-Fuel handling facilities and procedures.

4 -Radiation hazards that may arise during 4

6 7

Comments:

9 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 5 Examination Outline Cross-reference:

High Drywell Pressure / 5 Ability to determine and/or interpret the following as they apply to HIGH DRYWELL PRESSURE: (IOCFR 55.43.5)

Suppression pool temperature Proposed Question:

The plant is at 100%

Level Tier #

Group #

WA # 295024 Importance Rating power.

a) b)

c) d)

Proposed Answer:

The initial Dlant indications are:

- Torus Water Temperature 83 O F

- Torus pressure - 0 psig

- Drywell pressure 1.91 psig

- Safety Relief Valve A inadvertently opens.

10 Minutes later plant indications are:

- Torus Water Temperature 83 O F

- Torus pressure - 11.40 psig

- Drywell pressure 10.90 psig SRO 1

1 EA 2.06 4.1 The above primary containment readings indicate that the suppression function is (1)

(1) working correctly, (2) AOP-36, Stuck Open Relief Valve(s).

(1) bypassed, (2) AOP-1, Reactor Scram.

(1) working correctly, (2) AOP-36, Stuck Open Relief Valve(s).

(I) bypassed, (2) AOP-9, Loss of Primary Containment Integrity.

and the one of the procedures that the CRS should be using is (2) b) (1) bypassed,

12) AOP-1, Reactor Scram.

Explanation (Optional):

Justification: With the opening Of the SRV torus temperature remains constant but both torus pressure and pressure rise. Torus pressure is 0.5 psig higher than drywell pressure which indicates that the torus is pressurizing and lifting the torus to drywell vacuum breakers. The high DW pressure caused a scram and AOP-1 entry.

10 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 5 Continued Distracters: a)

(1) working correctly, (2) AOP-36, Stuck Open Relief Valve(s).

Justification: The lack of a torus temperature rise with both a torus and DW press rise indicates bypass of torus pressure suppression function.

c)

(1) working correctly, Justification: The lack of a torus temperature rise with both a torus and DW press rise indicates bypass of torus pressure suppression function.

d)

(I) bypassed, (2) AOP-9, Loss of Primary Containment Integrity.

Justification: Although Primary Containment is not functioning properly, its integrity remains intact and the entry conditions are NOT met for AOP-

9.

(2) AOP-36, Stuck Open Relief Valve(s).

Technical Reference(s):

AOP-1 AOP-9, AOP-36, (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Question Source:

Bank #

NONE Learning Objective:

SDLP-16A EO-1.09.e & f (AS available)

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Coanitive Level:

Memorv or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 11 of 60 Rev2

ES-40 1

Sample Written Examination Form ES-401-5 Question Worksheet Comments:

QUESTION # 5 Continued 55.43 5 - Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

5 12 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 6 Examination Outline Cross-reference:

High Reactor Pressure / 3 Ability to determine and/or interpret the following as they apply to HIGH REACTOR PRESSURE: (IOCFR 55.43.5) 0 Suppression pool level Proposed Question:

Proposed Answer:

Level Tier #

Group #

WA # 295025 importance Rating The plant was at 100% power:

SRO 1

1 EA 2.04 3.9 The initial plant indications were:

- RPV Pressure 1040 psig

- RPV Water Level 201.5 inches

- Torus Water Level 13.96 feet

- Torus Water Temperature 83 O F

- Drywell pressure 1.87 psig

- Steam Tunnel Temperature 120 O F With NO operator actions 10 Minutes later plant indications are:

- Reactor Mode Switch RUN

- RPS A & B Scram groups lights ON

- ARI Valves are OPEN

- RPV Pressure

- RPV Water Level

- Torus Water Level

- Torus Water Temperature

- Drywell pressure

- Steam Tunnel Temperature A low of 800 psig - slowly rising A low of 1 5 0 - slowly rising 14.12 feet - steady 95 O F - steady 1.87 psig - steady 140 O F - steady Which one of the following caused the increase in Suppression Pool level and which procedure is being used to address it?

A small break LOCA inside the drywell, AOP-39, Loss of Coolant.

A low vessel level, AOP-42, Feedwater Malfunction (Lowering Feedwater Flow).

A high RPV pressure, AOP-1, Reactor Scram.

A small main steam line break inside the steam tunnel, AOP 40, Main Steam Line Break.

c) A high RPV pressure, AOP-1, Reactor Scram.

13 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 6 Continued Explanation (Optional):

Justification: high RPV pressure (determined by ARI valves indications open) resulted in SRV operation and subsequent ARI rod insertion. RPV level was low enough to cause a scram signal at 177 but an ATWS occurred as evidenced by the scram lights being on.

This requires entry into AOP-1.

Distracters:

a) b)

Feedwater Flow).

d)

Main Steam Line Break.

Justification:

A small break LOCA inside the drywell, AOP-39, LOSS of Coolant.

A low vessel level, AOP-42, Feedwater Malfunction (Lowering A small main steam line break inside the steam tunnel, AOP 40, a) There is no evidence of a DW leak. DW pressure remains normal 10 minutes into the event.

b) A low vessel level and entry into AOP-42 is appropriate but would not cause a signal to be generated to lift the SRVs which in turn would cause the high torus level.

d) A break in the steam tunnel could cause the MSlVs to go close and, with an ATWS, would cause SRV operation. However, there is no steam tunnel temperature isolation as evidenced by normal temperatures.

Technical Reference(s):

AOP-1 AOP-36, AOP-39, (Attach if not previously provided)

AOP-40, Proposed references to be provided to applicants during examination: NONE Learning Objective:

SDLP-29 EO-1.09.b (As available)

Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Com p reh en si o n or Ana I y si s X

14 of 60 Rev2

ES-40 I Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 6 Continued 10 CFR Part 55 Content:

55.41 55.43 5 - Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

5 Comments:

15 of 60 Rev2

ES-40 1 Sample Written Examination Question Worksheet Form ES-401-5 QUESTION # 7 Examination Outline Cross-reference:

Level SRO Reactor Low Water Level / 2 Tier ##

1 Knowledge of the process for performing a Group #

1 containment purge. (1 OCFR 55.43.4)

WA # 295031 G 2.3.9 Importance Rating 3.4 Proposed Question:

The Plant is in Mode 4. There are planned maintenance activities inside the Drywell which includes interior grinding of Reactor Water Cleanup piping. To support this, a vent and purge of the drywell is being established per OP-37, Containment Atmosphere Dilution System.

To ensure a purge can be established the trip signal must be reset and, to minimize off-site releases, the CRS should direct the Low RPV Level (177 inches), Standby Gas Treatment system, High RPV Pressure (1080 psig), Standby Gas Treatment system, High RPV Level (222.5 inches), Drywell Ventilation and Cooling System, High Drywell pressure (2.7 psig), Drywell Ventilation and Cooling

System, be used for the purge.

a) b)

c) d)

Proposed Answer:

Explanation (Optional):

a) Low RPV Level ('I77 inches), Standby Gas Treatment system, Justification: LOW RPV level isolates the purge valves and SGT has HEPA and charcoal filters to remove particulates and gaseous radioactive material.

16 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 7 Continued Distracters:

b) High RPV Pressure (1 080 psig), Standby Gas Treatment system, c) High RPV Level (222.5 inches), Drywell Ventilation and Cooling

System, d) High Drywell pressure (2.7 psig), Drywell Ventilation and Cooling
System, JUSTIFICATION:

Hi DW pressure is the only signal in these 3 distracters that isolates Containment purge. Drywell Ventilation and Cooling does not limit or reduce the airborne activity created by the grinding of the cleanup system.

Technical Reference(s):

AOP-45, op-37 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

SDLP-16C EO-1.09.~

(As available)

Question Source:

Bank #

NONE Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Coanitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 55.41 10 CFR Part 55 Content:

55.43 4

Radiation hazards that may arise during normal and abnormal situations, including maintenance activities and various contamination conditions.

Comments:

17 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 8 Examination Ou tl ine C ross-refe ren ce:

High Reactor Pressure / 3 Ability to locate and operate components /

including local controls. { 1 OCFR 55.43.5)

Level Tier #

Group ##

WA # 295007 Importance Rating SRO 1

2 G 2.1.30 3.4 Proposed Question:

Given the following plant conditions:

Time T-0:

Reactor pressure

- 1039 psig APRM power

- 100%

Recirc Pump A speed

- 86%

- 87%

- OFF

- 40% open Recirc Pump B speed Load Limit Limiting Light

  1. 4 Turbine Control Valve Turbine Bypass Valves

- closed Time T-0 + 3 minutes:

Reactor pressure

- 1047 psig APRM power

- 105%

Recirc Pump A speed Recirc Pump B speed Load Limit Limiting Light

- 94%

- 87%

- ON

  1. 4 Turbine Control Valve
  1. I Turbine Bypass Valve

- FULL open

- 65% open Which one of the following actions should the CRS direct to exit ALL active LCOs and return Reactor pressure and power to normal?

Run Load Limit up until the Turbine Bypass valves close.

Run Load Set up until the Turbine Bypass valves close.

Reduce Recirc Pump A speed locally at the scoop tube.

Reduce Recirc Pump B speed at panel 09-4.

a) b)

c) d)

Proposed Answer:

c) Reduce Recirc Pump A speed locally at the scoop tube.

18 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 8 Continued Explanation (Optional):

Justification:

Recirc pump A runaway has resulted in Recirculation flow mismatch and entry into LCO 3.4.1. Correct answer c will restore Recirc pump A speed locally and bring the recirculation mismatch within limits.

Distracter d will result in making the mismatch greater. Distracter a & b will results in a raise in reactor pressure.

Distracters : Just if ic a t ion :

Technical Reference(s):

LCo 3.4.1 op-27, AOP-32, (Attach if not previously provided)

RAP-7.3.16, OP-9 Proposed references to be provided to applicants during examination:

Learning Objective:

SDLP-021 EO-I

.13. Given the (As available) procedure, discuss the procedure steps, administrative limitations, precautions, or cautions for the following:

NONE Question Source:

c.- operate the scoop tube positioner using the hand crank (OP-27).

Bank #

Modified Bank #

New X

(Note changes or attach parent)

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

19 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION ## 9 Examination Outline Cross-reference:

Level High Reactor Water Level / 2 Tier #

Ability to determine and/or interpret the Group #

following as they apply to HIGH REACTOR wA # 295008 WATER LEVEL: (10CFR 55.43.5)

Heatup rate: Plant-Specific Importance Rating Proposed Question:

Reactor Scram from 100% power has just Plant conditions are as follows:

Proposed Answer:

occurred 5 mil SRO 1

2 AA 2.04 3.3 lutes ago.

- RPV Water level dropped to 160 inches and was recovered rapidly to 220 inches

- Feedwater/HPCI/RCIC injection is secured to RPV

- RPV Pressure is 800 psig with a trend up at 10 psig per minute

- EHC pressure set is at 970

. psig

- Main Turbine Bypass Jack set is at 0% demand With no operator action, over the next 5 minutes, RPV Water level will entry and actions of

. To address the above conditions, the CRS should direct a) b, System c) d)

Lower due to cooldown, AOP-I Reactor Scram Rise due to swell from an open Safety Relief Valve, OP-I Main Steam Lower due to shrink from an open Main Turbine Bypass Valve, AOP-6 Malfunction of EHC Pressure Rise due to heatup, EOP-2 RPV Control d) Rise due to heatup, EOP-2 RPV Control Explanation (Optional):

Justification: The overfeeding upon the initial scram caused a cooldown and pressure reduction. With feed terminated, decay heat is causing the water to heat and the reactor to pressurize. Since level had dropped to less than 177, entry and actions of EOP-2 apply.

Distracters:

a) Lower due to cooldown, AOP-1 Reactor Scram b) Rise due to swell from an open Safety Relief Valve, OP-I Main Steam System c) Lower due to shrink from an open Main Turbine Bypass Valve, AOP-6 Malfunction of EHC Pressure Just if i cation :

a) With no feed or steam being drawn, decay heat will cause a heatup.

b) The rate of pressure rise over the next 5 minutes would 50 psig with total RPV pressure being 850 psig, less than the lift setpoint of an SRV.

c) Reactor pressure will be 850 psig in 5 minutes which is less than the 970 psig setpoint of EHC. Since 970 psig is the normal setpoint, there is no reason to believe that the controller has malfunctioned.

20 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 9 Continued Technical Reference(s):

AOP-1, op-1 I AOP-6, EOP-2 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

NONE Learning Objective:

SDLP- 06 EO-1.09.~

(As available)

Question Source:

Bank #

Modified Bank ##

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis 55.41 10 CFR Part 55 Content:

X 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

21 of 60 Rev2

Form ES-401-5 ES-40 1 Sample Written Examination Question Worksheet QUESTION # 10 Examination Outline Cross-reference:

Level SRO Inadvertent Reactivity Addition / 1 Tier #

1 Ability to determine and/or interpret the Group #

2 Reactor period Importance Rating 3.9 AA 2.02 following as they apply to INADVERTENT wA # 295014 REACTIVITY ADDITION: (1 OCFR 55.43.6)

Proposed Question:

To complete the core refuel, the into the top guide of the core at location 15-36.

The fuel bundle experiences binding which results in a Slack Cable indication.

Subsequently the bundle frees itself from the obstruction and quickly slides partway into the core till the Hoist Loaded indication is met.

The bundle stops approximately 2/3rds of the way into the core with its full weight on the hoist.

new bundle of fuel is being lowered INITIAL SRM INDICATIONS:

SRM A 30 CPS & 90 sec period SRM B SRM C SRM D 20 CPS & Infinite period 20 CPS & infinite period 15 CPS & Infinite period SRM INDICATIONS DURING BUNDLE DROP:

Proposed Answer:

SRM A SRM B SRM C SRM D Which reactor period indication is the MOST accurate indication of the fuel bundle movement incident?

Which SRM indications during the bundle movement incident require the evolution to be immediately stopped and the Refuel Bridge SRO to be notified per RAP-7,1.04.B, Neutron Instrumentation Monitoring During In-Core Fuel Handling?

SRM A period. SRM A&B.

SRM B period. SRM B&C.

SRM C period. SRM C&D.

SRM D period. SRM D & A.

65 CPS & 20 sec period 45 CPS & 90 sec period 25 CPS & 25 sec period 25 CPS & 120 sec period a) c)

b) d)

a) SRM A period. SRM A&B.

Expianation (Optional):

Justification: SRM A period is the most accurate as SRM A is located closest to the bundle. Per RAP-7.1.04.C Step 8.6 If loading fuel or withdrawing a control rod not immediately adjacent to a SRM/FLC AND count rate DOUBLES, THEN perform the following:

a) Immediately stop the evolution.

b) Notify Refuel Bridge SRO and SM.

This limitation was met with SRM A & B counts.

22 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 10 Continued Distracters: b) SRM 6 period. SRM B&C.

c) SRM C period. SRM C&D.

d) SRM D period. SRM D & A.

JUSTIFICATION: SRM A period is the most accurate as SRM A is located closest to the bundle. Per RAP-7.1.04.C Step 8.6 If loading fuel or withdrawing a control rod not immediately adjacent to a SRM/FLC AND count rate DOUBLES, THEN perform the following:

a) Immediately stop the evolution.

b) Notify Refuel Bridge SRO and SM.

This limitation was met with SRM A & B counts.

Technical Reference(s):

RAP-7-1-04.C (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

SDLP- 076 EO-1.12.d (As available)

SDLP-07B Figure I# 2 Question Source:

Bank #

Modified Bank #

New X

(Note changes or attach parent)

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

I O CFR Part 55 Content:

55.41 55.43 6

Procedures & limitations involved in initial core loading, alterations in core configuration, control rod programming & determination of various internal & external effects on core reactivity.

Comments:

23 of 60 Rev2

-w P

54 d

.,m.........u b

?

>..>>.... m__

1 OP-S3

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 11 Examination Outline Cross-reference:

Level H PCI Tier #

Knowledge of EOP layout / symbols / and icons. (1 OCFR 55.43.5)

Group ##

WA # 206000 Importance Rating Proposed Question:

Regarding the following EOP-2 Step:

SRO 2

1 G 2.4.19 3.7 I

The instructions to manipulate the controls for 23MOV-15 are contained in a(n) should and, when following the flowchart, the CRS Major Decision Point, continue and complete the step whenever the IF condition is met Override, continue and complete the step whenever the IF condition is met Action Statement, stop at this step and wait for the IF condition to be met before continuing Hold Point, stop at this step and wait for the IF condition to be met before continuing b) Override, continue and complete the step whenever the IF condition is met 25 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 11 Continued Explanation (Optional):

Justification: Per AP-02.02, EOP & SAOG, Step 5.7 this is an Override that provides guidance on the HPCI system among others.

An override must be continuously evaluated during the execution of a series of procedure steps.

Distracters:

a) Major Decision Point, continue and complete the step whenever the IF condition is met c) Action Statement, stop at this step and wait for the IF condition to be met before continuing d) Hold Point, stop at this step and wait for the IF condition to be met before continuing Justification:

a). Major Decision Points are enclosed in diamonds.

c) Action statements are simple direct instructions enclosed in rectangles d) Hold points are enclosed in octagons.

Technical Reference(s):

(Attach if not previously provided)

AP-02.021 EOP-2, EOP-39 EOP-4 & EOP-7

~~

~

Proposed references to be provided to applicants during examination:

EOP-2 Learning Objective:

MIT-301.I lA, EO-1.03.h (As available)

Question Source:

Bank #

Modified Bank #

New X

(Note changes or attach parent)

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

26 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 12 Examination Outline Cross-reference:

Level SRO SLC Tier #

2 Ability to analyze the effect of maintenance Group #

1 Importance Rating 3.8 G 2.2.24 activities on LCO status. (1 OCFR 55.43.2)

  1. 21, ooo The Plant is in Mode-I at 30% power during a startup.

Proposed Question:

Due to indications of bus overheating, L16 Bus was de-energized in preparation for corrective maintenance.

Compensatory actions have been taken per AOP-IgA, Loss of Switchgear L16.

The following items supplied by this bus are being evaluated for Technical Specification LCO actions:

- 11 P-2B B SLC Pump 125FN-1 B Standby Gas Treatment Filter Train B Fan Motor

- 13MOV-15 RClC Steam Supply lnbd lsol Valve Which of the following is the Technical Specification required action to be taken regarding the evaluation of these three items?

Restore SLC B subsystem in 7 days Restore SLC B subsystem in 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Enter LCO 3.03 Immediately Be in Mode 3 in 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> with steam dome pressure < 150 psig in 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> a) Restore SLC B subsystem in 7 days Explanation (Optional):

Justification: Refer to TS 3.1.7 Action A Distracterst b) Restore SLC B subsystem in 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> (Refer to TS 3.1.7 Action B for 2 SLC Inop-only 1 is inop for evaluation) c) Enter LCO 3.03 Immediately (Refer to TS 3.6.4.3 Action D for 2 SGTs inop-only one SGT is inop for evaluation) d) Be in Mode 3 in 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> with steam dome pressure < 150 psig in 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> (Refer to TS 3.5.3 action B incorrect RClC LCO allows 14 days the Containment Is01 Valve is inop as it is failed open, TS 3.6.1.3 Action A.l requires RClC Steam Line to be isolated in 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> which would then make RClC inoperable NOTE: this action was NOT provided as part of the distractor)

Technical Reference(s):

A O P - ~ ~ A I TS-3.1-7 Action A B, TS-3.6.4.3 Action D, TS-(Attach if not previously provided) 3.5.3 action A & B, TS-3.6.1.3 Action A.l Proposed references to be provided to applicants during examination: Tech Specs-No bases Learning Objective:

SDLP-11, EO-1.16 (As available)

Question Source:

Bank #

Modified Bank ##

(Note changes or attach parent) 27 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 12 Continued New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 2

Facility operating limitations in the tech specifications & their bases.

Comments:

28 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 13 Examination Outline Cross-reference:

Level SRO RClC Tier #

2 Ability to (a) predict the impacts of the 1

following on the REACTOR CORE A 2.11 ISOLATION COOLING SYSTEM (RCIC);

and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: (10CFR 55.43.5) 0 Inadequate system flow Importance Rating 3.2 Group #

WA # 21 7000 The Plant was at 100% when a Scram occurred.

RClC has automatically started from the standby line-up and is needed for injection.

RClC has been running for 5 minutes with the following indications:

- RCIC Flow CNTRL 13FIC-91

- 375 gpm

- TURB STM Supp VLV 13MOV-131 - Open

- INJ VLV 13MOV-21

- Open

- MIN FLOW VLV 13MOV-27

- Open

- VAC PMP 13P-3

- Running

- OIL CLR WTR SUPP 13MOV-132 -Open

- TEST VLV TO CST 13MOV-30

- Closed

- STM LINE DRN TO RADW 13AOV Closed

- STM LINE DRN TO RADW 13AOV Closed Proposed Question:

With these indications it has been determined that RClC is NOT operating normally.

a) b)

c) d)

Proposed Answer:

Which one of the following should the CRS direct the SNO to do to fully correct this situation?

Use the RClC Manual Startup for RPV Injection posted attachment to take manual control and adjust flow to normal.

Use the RClC Manual Startup for RPV Pressure Control posted attachment to Open 13MOV-30.

Use the RClC Auto-Initiation posted attachment to verify the position of 13MOV-27 and, when directed, close the valve.

Use the RClC Isolation Verification posted attachment to verify the position of 13MOV-30 and, when directed, open the valve.

c) Inform the CRS the Min Flow Valve 13MOV-27 is Open and use the RClC Auto-Initiation Dosted attachment to close 13MOV-27.

Expianation (Optional):

Justification: RClC fiOW is < 410 gpm, the only valve Out Of position is the Min Flow Valve 13MOV-27 which is Open and should be shut.

The posted attachment has a step to VERIFY (JAF PLANT SPECIFIC) the valve position, not ENSURE its position. Per AP-02.01 Verb List in Attachment # 1, VERIFY is defined as to observe that associated activities have been performed or exist, ENSURE provides direction to manipulate. The CRS needs to be informed prior to positioning since this is a VERIFY. The correct posted attachment to use is the RCIC Auto-Initiation posted attachment.

29 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 13 Continued Distracters:

a) to take manual control and adjust flow to normal.

b) attachment to Open 13MOV-30.

d) position of 13MOV-30 and, when directed, open the valve.

Justification: RClC flow is < 410 gpm, the only valve out of position is the Min Flow Valve 13MOV-27 which is OPEN and should be SHUT. The posted attachment has a step to VERIFY (JAF PLANT SPECIFIC) the valve position, not ENSURE its position. Per AP-02.01 Verb List in Attachment # 1, VERIFY is defined as to observe that associated activities have been performed or exist, ENSURE provides direction to manipulate.

The CRS needs to be informed prior to positioning since this is a VERIFY.

The correct posted attachment to use is the RClC Auto-Initiation posted attachment.

Use the RClC Manual Startup for RPV Injection posted attachment Use the RClC Manual Startup for RPV Pressure Control posted Use the RClC Isolation Verification posted attachment to verify the Technical Reference(s):

W-02.01, op-19. Drawing FM-22A (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

SDLP-13, EO-1.12.b (As available)

Question Source:

Bank #

NONE Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

30 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION ## 14 Examination Outline Cross-reference:

Level SRO SRVs Tier #

2 Ability to (a) predict the impacts of the 1

following on the RELIEF / SAFETY VALVES; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

(1 OCFR 55.43.5)

Group #

WA # 239002 A 2.01 0

Stuck open vacuum breakers Importance Rating 3.3 Proposed Question:

While performing ST-22B, Manual Safety Relief Valve Operations and Valve Monitoring System Functional Test (IST), the following Plant conditions were noted:

- RHR is in full Torus Cooling

- Suppression Pool Temperature is 90°F trending down

- Annunciator 09-4-2-6 SRV Sonic Mon Alarm Hi is alarmed

- SRV Sonic Mon Channel A meter is just in the RED region

- SRV 02RV-71A White Light is ON on Panel 09-4

- SRV 02RV-71A Control Switch is in Auto on Panel 09-4

- Torus Water Level is 13.9 feet and steady

- Torus Pressure is -0.03 psig and steady

- Drywell Pressure is 3.0 psig trending up

- Drywell Temperature is 97OF trending up

- Main Turbine Bypass Valves cycled closed 10% initially as expected when SRV 02RV-71A Control Switch was placed in Open during testing

- Main Turbine Bypass Valves cycled open 7% when SRV 02RV-71A Control Switch was returned to Auto from Open during testing

- AOP-36 Stuck Open Relief Valve(s) actions for removing the SRV fuses have been taken.

Besides the stuck open SRV, what other failure has occurred and what is the correct procedure to use?

SRV 02RV-71A vacuum breaker failed, EOP-4 Primary Containment Control SRV 02RV-71A vacuum breaker failed, AOP-9 Loss of Primary Turbine Bypass Valves failed, AOP-6 Malfunction of EHC Pressure Regulator Turbine Bypass Valves failed, EOP-2 RPV Control a) b, Containment Integrity d)

Proposed Answer:

a) SRV 02RV-71A vacuum breaker failed, EOP-4 Primary Containment Control 31 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 14 Continued Explanation (Optional):

Justification The SRV is stuck partially open, it is discharging directly into the DW through the SRV vacuum breakers as noted by DW press & temp increases & it is NOT going into the TORUS as noted by Torus temp & pressure. The Main Turbine Bypass valves (BPV's) have responded to the change in SRV position, initially closing about 10% when the SRV was open &would be expected to re-open 10% if the SRV went full shut, in this case they went open only 7% due to the SRV being partly open so they are responding correctly. EOP-4 is entered to mitigate containment challenges from direct pressurization due to the SRV Vacuum breaker being open with the SRV partially open. EOP-2 is a correct procedure to enter but when tied with the BPVs failure it is the wrong choice. AOP-6 is wrong as the EHC Pressure regulator has NOT malfunctioned. AOP-9 Loss of Primary Containment Integrity Entry conditions are NOT met. From SDLP-O2J, A failure of the vacuum Breakers to close would admit steam to the DW air space, resulting in rising DW press

& temp, upon subsequent SRV opening.

Distracters:

b) SRV 02RV-71A vacuum breaker failed, AOP-9 LOSS of Primary c) Turbine Bypass Valves failed, AOP-6 Malfunction of EHC Pressure d) Turbine Bypass Valves failed, EOP-2 RPV Control Justification: SRV is stuck partially open, it is discharging directly into the DW through the SRV vacuum breakers as noted by DW press & temp increases & it is NOT going into the TORUS as noted by Torus temp &

pressure. The Main Turbine Bypass valves (BPV's) have responded to the change in SRV position, initially closing about 10% when the SRV was open & would be expected to re-open 10% if the SRV went full shut, in this case they went open only 7% due to the SRV being partly open so they are responding correctly. EOP-4 is entered to mitigate containment challenges from direct pressurization due to the SRV Vacuum breaker being open with the SRV partially open. EOP-2 is a correct procedure to enter but when tied with the BPV's failure it is the wrong choice. AOP-6 is wrong as the EHC Pressure regulator has NOT malfunctioned. AOP-9 Loss of Primary Containment Integrity Entry conditions are NOT met.

From SDLP-O2J, A failure of the vacuum Breakers to close would admit steam to the DW air space, resulting in rising DW press & temp, upon subsequent SRV opening.

Containment Integrity Regulator Technical Reference(s):

ST-228, AOP-6, AOP-9, AOP-(Attach if not previously provided) 36, EOP-2, EOP-4 Proposed references to be provided to applicants during examination: None Learning Objective:

SDLP-O2J, EO-1.09.f

~~

(As available)

Question Source:

Bank #

Modified Bank #

New X

(Note changes or attach parent) 32 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 14 Continued Question History:

Last NRC Exam (Optional - Questions validated at the facility since IO/% will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

33 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 15 Examination Outline Cross-reference:

Level SRO Reactor Water Level Control Tier #

2 Knowledge of the process for controlling Group #

1 temporary changes. (IOCFR 55.43.3)

WA # 259002 G 2.2.11 Importance Rating 3.4 There is a tagout expected to be in place for greater than 90 days that tags out the A level column. In preparation for this tagout the B level column is to be selected for Feedwater Level Control. The tagout is to support a proposed change to Technical Specifications to move TS 3.3.2.2 Feedwater and Main Turbine High Water Trip Instrumentation to the Technical Requirements Manual (TRM).

Proposed Question:

The selection of the B Level Column and the associated tagout requires a High Water Trip Instrumentation to the TRM is controlled with

. The addition of the Feedwater and Main Turbine Proposed Answer:

Temporary Change to OP-2A Feedwater System, AP-02.04 Control of Procedures Temporary Change to OP-2A Feedwater System, AP-01.02 License and Technical Specification Administration 50.59 Screen per ST-IX Protected Tags and Temporary Alterations Audit, AP-02.01 Procedure Writers Manual 50.59 Screen per ST-1X Protected Tags and Temporary Alterations Audit, AP-20.06 Final Safety Analysis Report (FSAR) Amendment Preparation and Control d) 50.59 Screen per ST-1X Protected Tags and Temporary Alterations Audit, AP-20.06 Final Safety Analysis Report (FSAR) Amendment Preparation and Control Explanation (Optional):

50.59 Screen is required for tagouts expected to be in place >30 days per ST-1X Protected Tags and Temporary Alterations Audit, AP-20.06 Final Safety Analysis Report (FSAR) Amendment Preparation and Control controls changes to the TRM. Temporary Change to OP-2A is NOT required as it has a section G.29 for swapping from Water Column A to B.

a) Temporary Change to OP-2A Feedwater System, AP-02.04 Control of Procedures b) Temporary Change to OP-2A Feedwater System, AP-01.02 License and Technical Specification Administration c) 50.59 Screen per ST-1X Protected Tags and Temporary Alterations Audit, AP-20.06 Final Safety Analysis Report (FSAR) Amendment Preparation and Control Justification: 50.59 Screen is required for tagouts expected to be in place >30 days per ST-1X Protected Tags and Temporary Alterations Audit, AP-20.06 Final Safety Analysis Report (FSAR) Amendment Preparation and Control controls changes to the TRM. Temporary Change to OP-2A is NOT required as it has a section G.29 for swapping from Water Column A to B.

Distracters:

34 of 60 Rev2

Sample Written Examination Form ES-401-5 ES-401 Question Worksheet Technical peferencefs):

AP-20.6, ST-IX, AP-02.01 I (Attach if not previously provided)

\\ - J -

AP-01.02, AP-02.04, TRM, TS-3.3.2.2 QUESTION # 15 Continued

~

~~

Proposed references to be provided to applicants during examination:

Learning Objective:

LP AP, EO-1.01 (As available)

NONE Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Commehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 3

Facility licensee procedures required to obtain authority for design and operating changes in the facility.

Comments:

35 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 16 Examination Outline Cross-reference:

Level SRO Control Rod and Drive Mechanism Tier #

2 Ability to (a) predict the impacts of the Group #

2 A 2.01 following on the CONTROL ROD AND DRIVE MECHANISM; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: (1 OCFR 55.43.5) 0 Stuckrod importance Rating 3.6 Proposed Question:

WA # 201 003 During a Plant startup and heatup with the RPV pressure at 600 PSig, the following conditions were noted when the ROD MOVEMENT CNTRL switch was taken to Out Notch to move the selected rod to position 12:

09-5-2-1 RWM ROD BLOCK RPLS INOP - clear 09-5-2-2 ROD WITHDRAWAL BLOCK

- clear 09-5-2-3 ROD DRIFT

- clear 09-5-2-4 ROD OVER TRAVEL.

- clear Rod 22-39 indicating light on Full Core Display - ON Rod Out Perm light

- ON Rod 22-39 position

- 10 Rod In Green light Rod Out Red light Rod Settle Amber light IRMs - all mid scale Range 8 and steady with no change

- cycled ON and OFF

- cycled ON and OFF

- cycled ON and OFF Panel 09-5 Indications:

03PDI-302 CHG WTR Press

- 1500 psig Proposed Answer:

03PDI-303 DRV WTR Diff Press 03PDI-304 CLG WTR Diff Press 03PDI-305 DRV WTR Flow 03PDI-306 CLG WTR Flow Local Indications:

03Fl-216 Stab Valves A & B Outlet Flow Ind - 6 gpm NO actions have been taken in response to these conditions.

Use procedure The impact to the plant and equipment as noted in this procedure is AOP-24 Stuck Control Rod, damage to the drive mechanism seals.

AOP-24 Stuck Control Rod, over-heating the drive mechanism seals.

AOP-25 Uncoupled Control Rod, discharging reactor coolant to the Reactor Building Equipment Sump.

AOP-25 Uncoupled Control Rod, excessive reactivity addition rate.

- 650 psid

- 21 psid

- 0 gPm

- 60 gpm to respond to these conditions.

a>

b) c)

d) a) AOP-24 Stuck Control Rod, damage to the drive mechanism seals.

36 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 16 Continued Explanation (Optional):

Indications are rod did NOT move, both AOPs have symptoms Of lack of NI response to rod movement while AOP-24 includes RPlS failure to indicate rod motion. The candidate must also determine Drive DIP is excessive, > 600 psid with RPV pressure < 650 psig & per procedure caution, this condition could damage the drive mechanism seals. Overheating the seals would only apply if the cooling water was isolated but this was NOT done per the stem. The distracters for AOP-25 are part of a caution in regards to individual Scram to re-couple.

Distracters: b) AOP-24 Stuck Control Rod, over-heating the drive mechanism seals.

c) AOP-25 Uncoupled Control Rod, discharging reactor coolant to the d) AOP-25 Uncoupled Control Rod, excessive reactivity addition rate.

Justification: Indications are rod did NOT move, both AOPs have symptoms of lack of NI response to rod movement while AOP-24 includes RPlS failure to indicate rod motion. The candidate must also determine Drive D/P is excessive, > 600 psid with RPV pressure 650 psig & per procedure caution, this condition could damage the drive mechanism seals. Overheating the seals would only apply if the cooling water was isolated but this was NOT done per the stem. The distracters for AOP-25 are part of a caution in regards to individual Scram to re-couple.

Reactor Building Equipment Sump.

Techni cat Ref e rence( s) :

AOP-24, AOP-25 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

NONE Learning Objective:

LP AOP, EO-1.04 (As available)

Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

I O CFR Part 55 Content:

55.41 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

37 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 17 Examination Outline Cross-reference:

Level SRO Nuclear Boiler Inst.

Tier #

2 Ability to (a) predict the impacts of the 2

following on the NUCLEAR BOILER INSTRUMENTATION; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: (1 OCFR 55.43.5) 0 Instrument line leakage Importance Rating 3.1 Proposed Question:

Group #

WA # 216000 A 2.03 The plant is at 100%. Feedwater Level Control is in 3-element control and is selected to RPV Water Level Column B.

A report is received from a Radiation Protection Technician that the Reactor Building 344 ft ARM is in AWRM and steam and water is leaking into Reactor Building 300.

Coincident with the above the Control Room has the following indications: 5-1-28 RX WTR LVL ALARM HI OR LO 5-2-29 FDWTR CNTRL A OR B OR C HI RX LVL TRIP

- EPIC Pt #92-RFP HI WTR LVL A TRIP

- EPIC Pt #93-RFP HI WTR LVL B TRIP

- EPIC Pt #94-RFP HI WTR LVL C TRIP

- ON

- ON

- NORMAL

- TRIPPED

- NORMAL WITHOUT any operator actions the plant will respond by crew response, PRIOR to receiving any other alarms or indication changes shall be per Scramming, AOP-41 FEEDWATER MALFUNCTION (RISING FEEDWATER FLOW - HIGH RPV WATER LEVEL)and AOP-39 LOSS OF COOLANT Scramming, AOP-42 FEEDWATER MALFUNCTION (LOWERING b) FEEDWATER FLOW) and EOP-5 SECONDARY CONTAINMENT CONTROL c)

Continuing operation at a higher RPV level, AOP-41 FEEDWATER LEVEL) and EOP-5 SECONDARY CONTAINMENT CONTROL Continuing operation at a lower RPV level, AOP-42 FEEDWATER MALFUNCTION (LOWERING FEEDWATER FLOW) and AOP-39 LOSS OF COOLANT b) Scramming, AOP-42 FEEDWATER MALFUNCTION (LOWERING FEEDWATER FLOW) and EOP-5 SECONDARY CONTAINMENT CONTROL

, The a)

MALFUNCTION (RISING FEEDWATER FLOW - HIGH RPV WATER d)

Proposed Answer:

38 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 17 Continued Explanation (Optional):

Stem symptoms indicate 06LT-52B RPV WTR LEVEL X-mitter has a reference side instrument line break, D/P went to 0 resulting in a indicated high level as confirmed by annunciators & EPIC point with a confirmation provided by the RP Tech that line break is outside the CNMT in the RB. Report stipulates ARM alarm which would be an EOP-5 entry & exit from AOP-9. Without operator action, RPV level would lower to the low SCRAM setpoint as FW backs down due to B level x-mitter in control & it would be the dominant control signal over Steam & Feed flow. Crew response prior to receiving further alarms is to enter AOP-42 based on indications & EOP-5 based on RP Tech report.

39.

FEEDWATER FLOW - HIGH RPV WATER LEVEL)and AOP-39 LOSS OF COOLANT entry symptoms are present for AOP-41, AOP-I or AOP-Distracters:

a) Scramming, AOP-41 FEEDWATER MALFUNCTION (RISING c) Continuing operation at a higher RPV level, AOP-41 FEEDWATER LEVEL) and EOP-5 SECONDARY CONTAINMENT CONTROL d) Continuing operation at a lower RPV level, AOP-42 FEEDWATER MALFUNCTION (LOWERING FEEDWATER FLOW) and AOP-39 LOSS OF COOLANT Justification: Stem symptoms indicate 06LT-52B RPV VVTR LEVEL X-mitter has a reference side instrument line break, D/P went to 0 resulting in a indicated high level as confirmed by annunciators & EPIC point with a confirmation provided by the RP Tech that line break is outside the CNMT in the RB. Report stipulates ARM alarm which would be an EOP-5 entry &

exit from AOP-9. Without operator action, RPV level would lower to the low SCRAM setpoint as FW backs down due to B level x-mitter in control

& it would be the dominant control signal over Steam & Feed flow. Crew response prior to receiving further alarms is to enter AOP-42 based on indications & EOP-5 based on RP Tech report. NO entry symptoms are present for AOP-41, AOP-1 or AOP-39.

MALFUNCTION (RISING FEEDWATER FLOW - HIGH RPV WATER Technical Reference(s):

AOP-41 I AOP-42, AOP-9, (Attach if not previously provided)

AOP-1, EOP-5 Proposed references to be provided to applicants during examination:

Learning Objective:

SDLP-06, EO-l.lO.d (As available)

Question Source:

Bank #

EOP 5 Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge 39 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet 10 CFR Part 55 Content:

Comments:

QUESTION # 17 Continued Comprehension or Analysis 55.41 55.43 5

X Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

40 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 18 Examination Outline Cross-reference:

Level RHR/LPCI: Torus/Pool Cooling Mode Tier #

Ability to (a) predict the impacts of the Group #

WA # 219000 following on the RHR/LPCI: TORUS /

SUPPRESSION POOL COOLING MODE; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: (1 OCFR 55.43.5) 0 Valve logic failure: Plant-Specific Importance Rating Proposed Question:

The plant is operating at 100% power. The SNO is operating surveillance and reports that IOMOV-66A RHR HEAT EXCH BYPASS VLV will not close.

SRO 2

2 A 2.12 3.1 RHR for A

The CRS should declare the implement procedure a) Torus cooling, AP-10.01 Work Order Processing b) Torus cooling, AP-20.13 10CFR21 Reporting c)

LPCl flow, AP-05.13 Maintenance During LCOs d)

LPCl flow, AP-12.08 LCO Tracking and Safety Function Determination Program mode of RHR inoperable and Proposed Answer:

Explanation (Optional):

a) Torus cooling, AP-10.01 Work Order Processing With RHR HEAT EXCH A BYPASS VLV failing to remain shut due to the valve logic, it will NOT meet required heat removal capacity in A RHR loop. Procedures that apply are AP-10.01 (initiate a Work request), AP-12.08 & AP-05.13 are applicable procedures to be used but are NOT correct choices due to RHR will provide the required LPCl flow. AP-20.13 is NOT correct as a simple valve failure does not meet the reporting requirements.

QUESTION # 18 Continued Distracters:

b) Torus cooling, AP-20.13 I OCFR21 Reporting c) LPCl flow, AP-05.13 Maintenance During LCOs d) LPCl flow, AP-12.08 LCO Tracking and Safety Function Determination Program Justification:

AP-12.08 & AP-05.13 are applicable procedures to be used but are NOT correct choices due to RHR will provide the required LPCl flow. AP-20.13 is NOT correct as a simple valve failure does not meet the reporting requirements Technical Reference(s):

Op-13, op-1 3Bl TS-B3.5.1 I

(Attach if not previously provided)

B3.6.2.3, AP-10.01, AP-01.02, AP-05.13, AP-12.08 Proposed references to be provided to applicants during examination: NONE 41 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet Learning Objective:

SDLP-I 0, EO-1.09.d.2 (As available)

Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge 10 CFR Part 55 Content:

Comprehension or Analysis X

55.41 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

42 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 19 Examination Outline Cross-reference:

Level SRO Tier #

3 Knowledge of less than one hour technical Group #

1 specification action statements for systems.

wA # 2.1 G 2.1.11 (1 OCFR 55.43.2)

Importance Rating 3.8 Proposed Question:

The Plant is at 100% Power On 4/16/06.

- AOP-72, 1 15KV Grid Loss, Instability or Degradation has been entered at 19:OO on 4/16/06 due to a loss of Lighthouse Hill-Fitzpatrick Line #

3.

17:OO on 4/16/06 due to scheduled frequency.

- ST-9W Electrical Lineup and Power Verification was last performed at Applicable portions of ST-9R EDG System Quick-Start Operability Test and Offsite Circuit Verification must be performed next by a) 17:OO on 4/23/06 b) 11:OO on 4/25/06 c) 01:OO on 4/17/06 Proposed Answer:

Explanation (Optional):

Distracters:

a) b)

d) 20:OO on 4/16/06 Stem provided indications that one offsite power source was lost and thus requires entry into LCO 3.8.1 Action A requiring completion of SR 3.8.1.I within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> & once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> there-after to ensure that offsite power is available. LCO entry time is 19:OO making SR due by 20:OO. The 17:OO on 4/23/06 is the normal 7 day frequency based upon last completing the SR at 17:OO on 4/16/06. The choice of 11:OO on 4/25/06 allows for 1.25 extension of the normal 7 day frequency based upon SR 3.02. The choice of 01:OO on 4/17/06 is an 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> time based upon last completing the SR at 17:OO on 4/16/06. SR 3.02 is NOT allowed for the, perform within 1 hour-see example 1.4-2 in TS.

17:OO on 4/23/06 11 :00 on 4/25/06 c) 01:OO on 4/17/06 Justification: Stem provided indications that one offsite power source was lost and thus requires entry into LCO 3.8.1 Action A requiring completion of SR 3.8.1.1 within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> & once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> there-after to ensure that offsite power is available. LCO entry time is 19:OO making SR due by 20:OO. The 17:OO on 4/23/06 is the normal 7 day frequency based upon last completing the SR at 17:OO on 4/16/06. The choice of 11:OO on 4/25/06 allows for 1.25 extension of the normal 7 day frequency based upon SR 3.02. The choice of 01:OO on 4/17/06 is an 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> time based upon last completing the SR at 17:OO on 4/16/06. SR 3.02 is NOT allowed for the, perform within 1 hour-see example 1.4-2 in TS.

43 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 19 Continued Technical Reference(s):

AOP-72, sT-9w1 ST-~RI TS-SR (Attach if not previously provided) 3.02, TS-3.8.1, SR-3.8.1.1, TS-B3.8.1 Proposed references to be provided to applicants during examination: Technical Specs-No Bases Learning Objective:

SDLP-71 D, EO-1.I6 (As available)

Question Source :

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 2

Facility operating limitations in the technical specifications and their bases.

Comments:

44 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 20 Examination Outline Cross-reference:

Level SRO Tier #

3 Ability to supervise and assume a Group #

1 management role during plant transients wA # 2.1 G 2.1.6 and upset conditions. (10CFR 55.43.5)

Importance Rating 4.3 Proposed Question:

The Plant is at 70% power to allow removing A Feedwater Pump from service for maintenance.

- All 3 Circ Water Pumps are in service.

- Tempering is in progress to maintain Cond Demin inlet temperature

- Lake level went from 245.5 ft to 242.5 ft in the last 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> as noted

- The Outside NPO reports that there is NO ice formation on the

- Traveling Screens are Continuous Run with indications of debris in In accordance with AOP-64 Loss of Intake Water Level, which of the following actions will be the next required action to perform?

Raise tempering flow per OP-4 Circulating Water System Reduce Reactor Power to less than 65% per RAP-7.3.16 Plant Power Stop Circ Wtr Pump C 36P-IC per OP-4 Circulating Water System 95-1 OOOF..

on EPIC Log 1.

traveling screens or intake structure.

the Fish Basket.

a) b, Changes c) d)

Manually Scram the Plant per AOP-1 Reactor Scram Proposed Answer:

Explanation (Optional):

b) Reduce Reactor Power to less than 65% per RAP-7.3.16 Plant Indications are provided that the loss of intake level is due to other than ice formation. AOP-64 requires power reduced to < 65% prior to stopping CW Pump C if lake level has lowered > 2 ft in the last 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> as stipulated in the stem. The plant is manually scrammed if lake level is < 240 ft which was NOT given in the stem. Raise tempering flow per OP-4 section G if Ice formation is the cause of the lowering level, this was NOT given in the stem, in fact indications reported locally of ice formation in the intake structure was provided in the stem.

Power Changes 45 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 20 Continued Distracters:

a) Raise tempering flow per OP-4 CiWlating Water System c) Stop Circ Wtr Pump C 36P-IC per OP-4 Circulating Water System d) Manually Scram the Plant per AOP-I Reactor Scram Justification: Indications are provided that the loss of intake level is due to other than ice formation. AOP-64 requires power reduced to 65%

prior to stopping CW Pump C if lake level has lowered > 2 ft in the last 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> as stipulated in the stem. The plant is manually scrammed if lake level is c 240 ft which was given in the stem. Raise tempering flow per OP-4 section G if Ice formation is the cause of the lowering level, this was NOT given in the stem, in fact indications reported locally of ice formation in the intake structure was provided in the stem.

Technical Reference@):

AOP-64 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

Learning Objective:

LPAOP, EO-1.03.a (As available)

Question Source:

Bank ##

NONE Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

46 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 21 Examination Outline Cross-reference:

Knowledge of the process for managing maintenance activities during power operations. (1 OCFR 55.43.5)

Proposed Question:

Proposed Answer:

The Plant is at 100%

Level Tier #

Group #

K/A# 2.2 Importance Rating power on a Sunday I light.

SRO 3

2 G 2.2.17 3.5

- Condensate Pump A has developed a leak that requires it to be

- The Operating Shift has determined that the Plant will be De-rated to For the conditions above, the NYPA Energy Control Center is required to be notified by the Operations Manager; EN-OP-115, Conduct of Operations Reactor Engineer; RAP-7.3.16, Plant Power Changes Shift Manager; AP-12.13, 3491 15 KV Transmission Line Operations and Interface Work Control Center Supervisor; OP-65, Startup and Shutdown Procedure c) Shift Manager; AP-12.13, 345/115 KV Transmission Line removed from service within the next hour.

65% power to support the repair work.

per procedure Operations and Interface Explanation (Optional):

AP-12.13 provides guidance for NYPA ECC interface for this situation while OP-65 has a step to notify ECC of a shutdown schedule, the plant is NOT being shutdown but is being de-rated. Per AP-12.13, Operations Manager is responsible for overall implementation of this procedure. Reactor Engineer (RE) is responsible to coordinate generation scheduling with ENN Power Marketing. Advanced Scheduling: All generation scheduling will be done between ENN Power Marketing & RE Dept. RE should notify ENN On-Call Scheduler at least 7 days in advance of any planned power changes. The Shift Manager (SM) is responsible for authorizing access to JAF Switchyard, communicating with transmission operator for resolving emergent issues. SM is responsible for changes to unit power scheduling with NYISO. Work Control Center Supervisor (WCCS)is responsible for ensuring that 115/345KV work with potential to affect operation of JAF, are scheduled on the weekly work schedule per AP-10.02 "12 Week Rolling Schedule", & coordinated by the JAF 115/345 KV Coordinator. JAF 115KV/345KV Coordinator is responsible to interface with Power Control & Regional Central Control to review, coordinate & schedule line outages & work that has potential for causing an unplanned line outage. WCCS is the 115/345 KV coordinator. Real-Time Operations: For unplanned down powers or delayed power restorations, JAF Ops is required to contact NYPA ECC for a "derate", the term "derate" must be used & give plant status. FOR the stem conditions, the only member of Operations present at Sunday night would be the SM as the OM is off.

47 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 21 Continued Distracters:

a) Operations Manager; EN-OP-I 15, Conduct of operations b) Reactor Engineer; RAP-7.3.16, Plant Power Changes d) Work Control Center Supervisor; OP-65, Startup and Shutdown Justification: AP-12.13 provides guidance for NYPA ECC interface for this situation while OP-65 has a step to notify ECC of a shutdown schedule, the plant is NOT being shutdown but is being De-rated. Per AP-12.1 3, Operations Manager is responsible for overall implementation of this procedure. Reactor Engineer (RE) is responsible to coordinate generation scheduling with ENN Power Marketing. Advanced Scheduling: All generation scheduling will be done between ENN Power Marketing & RE Dept. RE should notify ENN On-Call Scheduler at least 7 days in advance of any planned power changes. The Shift Manager (SM) is responsible for authorizing access to JAF Switchyard, communicating with transmission operator for resolving emergent issues. SM is responsible for changes to unit power scheduling with NYISO. Work Control Center Supervisor (WCCS)is responsible for ensuring that 11 5/345KV work with potential to affect operation of JAF, are scheduled on the weekly work schedule per AP-I 0.02 "1 2 Week Rolling Schedule", &

coordinated by the JAF 1 15/345 KV Coordinator. JAF 11 5KV1345KV Coordinator is responsible to interface with Power Control & Regional Central Control to review, coordinate & schedule line outages & work that has potential for causing an unplanned line outage. WCCS is the 115/345 KV coordinator. Real-Time Operations: For unplanned down powers or delayed power restorations, JAF Ops is required to contact NYPA ECC for a "derate", the term "derate" must be used & give plant status. FOR the stem conditions, the only member of Operations present at Sunday night would be the SM as the OM is off.

Procedure Technical Reference($:

AP-12-13, EN-OP-115, op-65, (Attach if not previously provided)

RAP-7.3.16 Proposed references to be provided to applicants during examination:

Learning Objective:

LPAP, EO-20.02 (As available)

NONE Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam

~~

(Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge X

Comprehension or Analysis 10 CFR Part 55 Content:

55.41

~~

48 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 21 Continued 55.43 5

Assessment of Facility conditions and selection of appropriate procedures during normal, abnormal, and emergency situations.

Comments:

49 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 22 (1 OCFR 55.43.6)

Proposed Question:

Examination Outline Cross-reference:

Level SRO Tier #

3 WA# 2.2 G 2.2.27 Knowledge of the refueling process.

Group #

2 Importance Rating 3.5 The plant is in a refuel outage and fuel movement is underway. The a) b)

c) d)

Proposed Answer:

next'move per SNM move sheet 06-058, step 275, is fuel bundle (YJX 230) which is being moved into core location 43-48 (Clip NE).

A Refuel Error per RAP-7.I.04Bl Refueling Procedure, would occur if the bundle has its nose cone partially inserted into 43-48 (Clip SE) then is changed to 43-48 (Clip NE) prior to the start of the next move.

is inserted 30 inches into location 03-32 (Clip NE) and is subsequently removed and inserted into location 43-48 (Clip NE).

Is moved from core location 39-42 (Clip SE) and is returned to location 39-42 (Clip SE) due to poor visibility in location 43-48.

is fully inserted into 43-48 (Clip SE) with the grapple disengaged and then is changed to 43-48 (Clip NE) prior to the start of the next move.

subsequently removed and inserted into location 43-48 (Clip NE).

b) is inserted 30 inches into location 03-32 (Clip NE) and is Explanation (Optional):

Per RAP-'1. I.04B, 5.9 Refuel Error, the only choice that constitutes a refuel error is '6' as the nose cone is partially inserted into the wrong location. Distractor 'A'

& 'D' are wrong orientation that is corrected prior to start of next move. Distractor 'C is NOT a refuel error per step 5.9.3.

5.9.1 A fuel bundle fully or partially placed (i.e., past the nose cone) in 5.9.2 A mis-orientated fuel bundle is not considered a Refuel Error if an incorrect location is a Refuel Error.

the miss-orientation is corrected immediately. It is a Refuel Error if the mis-orientated bundle is identified after the start of the next move.

reason and the bundle is returned to the starting location.

5.9.3 It is not a Refuel Error if a move cannot be completed for any 50 of 60 Rev2

ES-40 1 Sample Written Examination Question Worksheet Form ES-401-5 QUESTION # 22 Continued Distracters: a) has its nose cone partially inserted into 43-48 (Clip SE) then is changed to 43-48 (Clip NE) prior to the start of the next move.

c) Is moved from core location 39-42 (Clip SE) and is returned to location 39-42 (Clip SE) due to poor visibility in location 43-48.

d) is fully inserted into 43-48 (Clip SE) with the grapple disengaged and then is changed to 43-48 (Clip NE) prior to the start of the next move.

Justification:

Per RAP-1.1.04B. 5.9 Refuel Error, the only choice that constitutes a refuel error is 'B' as the nose cone is partiaily inserted into the wrong location. Distractor 'A' & 'D are wrong orientation that is corrected prior to start of next move. Distractor 'C' is NOT a refuel error per step 5.9.3.

5.9.1 A fuel bundle fully or partially placed (Le., past the nose cone) in an 5.9.2 A mis-orientated fuel bundle is not considered a Refuel Error if the incorrect location is a Refuel Error.

miss-orientation is corrected immediately. It is a Refuel Error if the mis-orientated bundle is identified after the start of the next move.

5.9.3 It is not a Refuel Error if a move cannot be completed for any reason and the bundle is returned to the starting location.

(Attach if not previously provided)

Technical Ref e re nce( s) :

RAP-7.1-04B Proposed references to be provided to applicants during examination:

Learning Objective:

LPAP, EO-73.04 (As available)

NONE Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 6

Procedures 8, limitations involved in initial core loading, alterations in core configuration, control rod programming & determination of various internal 8, external effects on core reactivity.

Comments:

5 1 of 60 Rev2

ES-401 Sample Written Examination Question Worksheet Form ES-401-5 (1 OCFR 55.43.4)

Proposed Question:

QUESTION # 23 Examination Outline Cross-reference:

Level SRO Tier #

3 Knowledge of the requirements for Group #

3 reviewing and approving release permits.

wA # 2.3 G 2.3.6 Importance Rating 3.1 The plant is in cold shutdown and all equipment is operable. A liquid Radwaste discharge to the canal is aboutto occur. An independent review of the Canal Discharge Worksheet (attached) by the FSS shows that the discharge should NOT take place. The reason for this is that:

The Chemistry Superintendents signature is required An Independent Analysis signature is required The radiation monitor, 17RM-350, alarm and isolation setpoints should be set lower.

The radiation monitor, 17RM-350, alarm and isolation setpoints should be set higher d) The radiation monitor, 17RM-350, alarm and isolation setpoints should be set higher Explanation (Optional):

The canal discharge activity level is obtained from the discharge permit. The permit activity is larger than the number recorded on the worksheet. A larger activity number, if used on the worksheet, would calculate to a higher monitor setpoint. Thus, since a lower activity number was used, a lower alarm and setpoint were used.

Choice A is wrong because the Chemistry Superintendents signature is required if the minimum CW pumps (I) are not operating.

Choice E3 is wrong because an independent analysis is required if the radiation monitor is inoperable.

Choice D is wrong because the actual activity number, 3.8xE-4 is larger than the number on the worksheet of 2.8xE-5.

The question is higher order in that the candidate must analyze the calculations and required signatures to see what mistake was made.

With the mistake determined to be an incorrect transcribe activity number he must analyze and determine how this affects the setpoint settings without having the formula to actually calculate the setpoint.

52 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 23 Continued Distracters:

Technical Reference(s):

op-49 Liquid Radioactive Waste (Attach if not previously provided)

Svstem Proposed references to be provided to applicants during examination: Provide calculator and filled in discharge permit and worksheet.

Learning Objective:

SDLP-20, EO 1.13 (As available)

Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 4

Radiation hazards that may arise during normal & abnormal situations, including maintenance activities & various contamination conditions.

Comments:

53 of 60 Rev2

Sample Written Examination Form ES-401-5 ES-40 1 Question Worksheet Time Dilution Water Pumps Level Rate Operating Circ Service DISCHARGE DATA Date start Pumpout STE DISCHARGE PERMIT Page 1 of 1 Tank'%

1 ReleaseBatchNo. #.?

I Sample DatefTime & /!,!?id% cm]

operator Initials Independent analysis is required for discharge without operable radiation monitor. Otherwise, mark Nk Independent Analysis by (Print/Siqn):

,.si4 I Date 6 / i 9 j o ~ l mme 0

~ Q Q

, End Pompout I

cps Discharge valve lineup returned to normal in accordance with canal discharge shutdown lineup for appficable tank:

Tf3l-k Aw. Qerator (PrinVSign):

Date Time I

FORWARD DISCHARGE PERMIT TO CHEMISTRY IMMEDIATELY FOLLOWING DISCHARGE Flw Rcdr Reading 20FR-441 gpm Discharge valve lineup returned to normal in accordance with canal discharge shutdown lineup for appficable tank:

Tf3l-k Aw. Qerator (PrinVSign):

Date Time I

FORWARD DISCHARGE PERMIT TO CHEMISTRY IMMEDIATELY FOLLOWING DISCHARGE 54 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet c

wo xs Page 1 of 2 DATA

1.

Number of running circulating water pumps (36P-:A/S/C) 1 2.

Number o f running se-mice water pumps (46P-lA/B/CI c=k 3.

Tank Discharge Flow Rate (maximum) TDFR GJPm

-5 4.

pCi/n'd (from discharge permit)

5.

Required Dilution Factor (DF) 100 (from discharge permit)

Tank Activity (ACT) A*

2Y ic

6.

Liquid rad monitor (17RM-350) reading 70 CPS

( EPIC-A-12 0 9

)

NOTE 1:

Items 7 and 8 are obtained at panel 09-14 NOTE 2: Background should be maintained LESS THAN 1000 cps.

It is recommended that the detector canister be flushed to levels below this prior to discharge.

7.

Liquid rad monitor (17RM-350) background

?3 cps 8.

Liquid rad monitor (17RM-350) K-factor J3G4%br.J pCi/ml/cps

&- 7

9.

Tenpering gate/flow 0

(EPIC-A-3547)

CALCULATIONS

10. CFR = I (I1 X 120,000)+(#2 X 18.00O)I x 1 (1 -

gPm

11. Calculate Canal Dilution Factor (CDF):

CFR

  1. 10 I

NOTE :

F,= Fraction of allowed dilution (dimensionless, m u s t be

12. Calculate F,:

less than 1.0 f o r discharge).

F, = CDF X DF = #11 X # S =

  • O t
13. Calculate Backgrour,d Correction Activity (BCA) in pCi/ml:

COMPLETED FORMS ARE ATTACHED TO THE DISCHARGE PERMIT 55 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet CAXAL DISCHARGE WORKSHEET Page 2 of 2

14. Calculate Hi/Hi setpoint in pCi/rnl:

Hi/Hi =

(ACT) =

  1. 4

+ #13 =

2 X F, 2 X #I2

15. Calculate Hi setpoint in pCi/ml:

Hi =

(ACT) =

  1. 4

+ #13 =

UCi /ml 4 X F, 4 X #12

16. Obtain 17RM-350 potentiometer setting for Hi-Hi setpoint from Chemistry I

7 Hi/Hi

'J

. i p 0

17. Obtain 17RM-350 potentiometer setting for Hi setpoint from Chemistry.

Hi I

18. Enter potentiometer settings for Hi and Hi-Hi setpoints on Discharge Permit Section B and attach this worksheet to the discharge permit.

Independent Verification Print/Sign/Date COXPLETED FORMS AICE ATTACHED TO TXE DISCHARGE PERMIT OP-49 LIQUID RADIOACTIVE ATTACHMENT 5 Rev. No. 55 WASTE SYSTEM Page 218 of 220 56 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 24 Examination Outline Cross-reference:

Knowledge of facility ALARA program.

(1 OCFR 55.43.4)

Level Tier #

Group #

WA# 2.3 SRO 3

3 G 2.3.2 Importance Rating Proposed Question:

The CRD Drive Water Filter B requires changing and the following conditions exist:

- Two NPOs are available to perform this task, NPO Alpha is more

- NPO Alpha estimates that he could change the Filter in 20 minutes.

- NPO Beta (less experienced) estimates that he could change the Filter

- RP estimates it would take 2 people, 15 minutes total to install and

- Portable shielding would result in zero mr exposure to personal experienced and has performed the task before.

in 60 minutes.

remove portable shielding to support the Filter change.

performing the Filter change.

In support of Plant AIARA goals, the CRS should direct a) b)

c.

d)

NPO Alpha to change the Filter after shielding is installed.

NPO Beta to change the Filter after shielding is installed.

NPO Beta to change the Filter immediately.

NPO Alpha to change the Filter immediately.

Proposed Answer:

Explanation (Optional):

d) NPO Alpha to change the Filter immediately.

d) Dose rate received will be 20 minutes to NPO. Total = 20 minutes man-rem.

Distracters: a) NPO Alpha to change the Filter after shielding is installed.

b) NPO Beta to change the Filter after shielding is installed.

c) NPO Beta to change the Filter immediately.

Just if i cation :

a) Dose rate received will be 30 minutes to RP & 0 minutes to NPO.

Total = 30 minutes man-rem.

b) Dose rate received will be 30 minutes to RP & 0 minutes to NPO.

Total = 30 minutes man-rem.

c) Dose rate received will be 60 minutes to NPO. Total = 60 minutes man-rem.

Technical Ref ere nce (s) :

o p-25 B A P-07.03 (Attach if not previously provided)

Proposed references to be provided to applicants during examination:

NONE Learning Objective:

LPAP, EO- 07.03 2.9

~

(As available) 57 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

QUESTION # 24 Continued New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10/95 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 4

Radiation hazards that may arise during normal & abnormal situations, including maintenance activities & various contamination conditions.

Comments:

58 of 60 Rev2

ES-40 1 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 25 Examination Outline Cross-reference:

Level SRO Tier ##

3 Ability to perform without reference to Group #

4 procedure those actions that require WA# 2.4 G 2.4.49 immediate operation of system components and controls. (1 OCFR 55.43.2)

Importance Rating 4.0 Proposed Question:

The Plant iS at 100% power.

The following event and indications occur subsequently:

- Feedwater Pump A trips off.

- RWR Pump A trips off

- RWR Pump B - speed 30%

- Annunciator 09-5-2-44 APRM UPSCALE - ON

- All APRM recorders - Cycling 65% to 77% every 2 seconds

- All SRM Period meters - Cycling minus 80 to plus 30 seconds every 1

- Various LPRM Upscale Alarms - Alarming and clearing every 2 Which safety limit is challenged by these indications and which of the following is immediately required?

a)

RPV Steam Dome Pressure, Close RWR Pump Disch Vlv 02MOV-53A b)

RPV Steam Dome Pressure, Insert CRAM Groups c)

MCPR, Manually Scram the Reactor

% seconds seconds Proposed Answer:

d)

MCPR, Raise RWR Pump B speed and flow c) MCPR, Manually Scram the Reactor.

Explanation (Optional):

AOP-8 Loss or Reduction of Reactor Coolant Flow requires immediate action to manually SCRAM if indications of thermal hydraulic instabilities (THI) are observed. Refer to Attachment 1 of AOP-8 for Indications of THI. Distracters are part of Prompt actions vice immediate actions. Stem provides indications of THI. TS Bases 3.4.1 identifies THI as a challenge to the MCPR safety limit.

Distracters:

a) RPV Steam Dome Pressure, Close RWR Pump Disch Vlv 02MOV-53A b) RPV Steam Dome Pressure, Insert CRAM Groups d) MCPR, Raise RWR Pump B speed and flow Justification: AOP-8 Loss or Reduction of Reactor Coolant Flow requires immediate action to manually SCRAM if indications of thermal hydraulic instabilities (THI) are observed. Refer to Attachment 1 of AOP-8 for Indications of THI. Distracters are part of Prompt actions vice immediate actions. Stem provides indications of THI. TS Bases 3.4.1 identifies THI as a challenge to the MCPR safety limit.

Technical Reference@):

AOP-8, TS-Bases 3.4.1, (Attach if not previously provided)

CR-JAF-2000-06312 (SER 7-00, Reference Only BWR Core Power Oscillations)

Proposed references to be provided to applicants during examination: NONE 59 of 60 Rev2

ES-401 Sample Written Examination Form ES-401-5 Question Worksheet QUESTION # 25 Continued Learning Objective:

LPAOP, EO-1.03.a (As available)

QUESTION # 25 Continued Question Source:

Bank #

Modified Bank #

(Note changes or attach parent)

New X

Question History:

Last NRC Exam (Optional - Questions validated at the facility since 10195 will generally undergo less rigorous review by the NRC; failure to provide the information will necessitate a detailed review of every question.)

Question Cognitive Level:

Memory or Fundamental Knowledge Comprehension or Analysis X

10 CFR Part 55 Content:

55.41 55.43 2

Facility operating limitations in the tech specifications & their bases.

Comments:

60 of 60 Rev2