ML061390201
| ML061390201 | |
| Person / Time | |
|---|---|
| Site: | Prairie Island, Surry, North Anna |
| Issue date: | 05/17/2006 |
| From: | - No Known Affiliation |
| To: | Office of Nuclear Reactor Regulation |
| Thompson, J W, NRR/DIRS/IPAB, 415-1011 | |
| References | |
| Download: ML061390201 (4) | |
Text
- V_
FAQ 60.3 1
FAQ 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Plants:
Date of Event:
Submittal Date:
Licensee
Contact:
Prairie Island/Surry NA April 10, 2006 Jayne Ritter (Prairie Island)
Don Olson (Dominion)
Tel/email: (651) 388-1121 x4125 Jayne.Rittergnmcco.com Tel/email: (804) 273-2830 DonOlsongdom.com Tel/email: (301) 415-5472 Dad3@nrc.gov NRC
Contact:
Don Dube Performance Indicator: MSPI Site Specific FAQ (Appendix D)? Yes FAQ requested to become effective when approved.
Ouestion Section NEI 99-02 guidance needing interpretation:
Page F-32 provides no generic common cause correction factor for diesel-driven service water pumps. Likewise, there is no industry prior information associated with this component type on Table 4 on page F-37. Consequently, CDE 3.0 has not been constructed to recognize diesel-drive service water pumps.
Event or circumstances requiring guidance interpretation:
Prairie Island has two diesel-driven service water pumps that are monitored under MSPI.
Surry has 3 diesels-driven service water pumps that are monitored under MSPI.
Response Section Due to insufficient industry data upon which to develop a separate set of parameters for this component type, an existing component type should be chosen. Given that the failures for this type of pump are expected to be dominated by the driver rather than the pump, the diesel-driven AFW pump component type should be used.
Page 1 of 1
FAQ Log 5/17106 TempNo.
PI Topic Status Plant/ Co.
58.4 EPOl Drill/Exercise Performance 1/26/06 Introduced and NRC EP02 ERO Drill Participation revised during meeting 2/21/06 Revisions to response 2/23/06 Discussed 3/23/06 Discussed.
Response to be revised by NEI.
4/19/06 Response revised 4/20/06 Tentative
~~Approval 60.3 MSPI MSPI Service Water Pump 4/20/06 Introduced Prairie values 4/20/06 Tentative
North Anna Date of Event:
6/30/05 Submittal Date:
9/9/05 Licensee
Contact:
Tel/email:
NRC
Contact:
Lee Miller Tel/email: 404-562-4676, Irm@nrc.gov Performance Indicator:
Drill and Exercise Performance and Emergency Response Organization Participation Site-Specific FAQ (Appendix b)?
No FAQ requested to become effective when approved QUESTION SECTION Event of Circumstances requiring guidance interpretation:
If a licensee were to wait until the ERO assignment process was completed before crediting the DEP performance indicator for an ERO-member-in-training, then the opportunity could be counted in a reporting period other than the one in which the performance enhancing experience occurred. At North Anna, a performance enhancing experience was provided to new ERO member before they assumed their ERO position.
The ERO member assumed their ERO position one day later; however, that day spanned reporting periods.
Question: How and when should DEP PI opportunities for ERO-members-in-training be counted?
RESPONSE SECTION Proposed Resolution of FAQ:
PI opportunities and participation credit should not be counted for ERO-members-in-training. DEP opportunities are only counted for plant staff members who are currently assigned to fill a key position on the ERO.
Background:
NEI 99-02, page 79, Line 31 states "The percentage of drill, exercise, and actual opportunities that were performed timely and accurately by Key Positions, as defined in the ERO Drill Participation indicator,....
NEI 99-02, page 86, Line 11 states, "...ERO members assigned to fill Key Positions.
Page 1 of 2
-j-FAQ 58.4 Discussion:
The participation Pi tracks Key ERO members assigned to the ERO. The key word here is assigned. Trainees are not assigned to the ERO and therefore DEP opportunities or participation does not count.
Data reporting may be affected in accordance with this FAQ at some plants.
There is no need to modify past record keeping practices based on this FAQ.
Record keeping practices should only be modified for practices conducted after this FAQ is approved.
If appropriate, provide proposed rewording of guidance for inclusion in next revision: