6vEntergy Entergy Nuclear Operations, Inc.
Pilgrim Station 600 Rocky Hill Road Plymouth, MA 02360 May 11, 2006 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555
SUBJECT:
Entergy Nuclear Operations, Inc.
Pilgrim Nuclear Power Station Docket No. 50-293 License No. DPR-35 Annual Radiological Effluent and Waste Disposal Report for January 1 through December 31, 2005 LETTER NUMBER:
2.06.039
Dear Sir or Madam:
In accordance with Pilgrim Technical Specifications 5.6.3, Entergy Nuclear Operations, Inc. submits the attached Annual Radiological Effluent and Waste Disposal Report for January 1 through December 31, 2005.
Should you have questions or require additional information, I can be contacted at (508) 830-8403.
This letter contains no commitments.
Sincerely, Bryan Ford WGL/dm
Attachment:
Pilgrim Nuclear Power Station Radiological January 1 through December 31, 2005 cc:
U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector Effluent and Waste Disposal Report, Mr. James J. Shea, Project Manager Office of Nuclear Reactor Regulation Mail Stop: 0-8B-1 U.S. Nuclear Regulatory Commission 1 White Flint North 11555 Rockville Pike Rockville, MD 20852
- I C-6 (/- 9 206039
PILGRIM NUCLEAR POWER STATION Facility Operating License DPR-35 Radiological Effluent and Waste Disposal Report January I through December 31, 2005 S ~ 0.
....l. -..f.
PILGRIM NUCLEAR POWER STATION Facility Operating License DPR-35 RADIOACTIVE EFFLUENT AND WASTE DISPOSAL REPORT JANUARY 01 THROUGH DECEMBER 31, 2005 A3-e%4?,'a Prepared by Reviewed by Reviewed by K.J. Sejkoq7 Sen Chnertrny S cialist
{:
151yl
/Xoro 7:
T.F. McElhinney I
Chemistry Superintendent zv22 I/ /
P.J. McNultf/
Radiation Protection Manager
__I-2
Pilgrim Nuclear Power Station Effluent and Waste Disposal Report January-December 2005 TABLE OF CONTENTS SECTION SECTION TITLE PAGE 1.0 2.0 2.1 2.2 2.3 3.0 4.0 4.1 4.2 4.3 5.0 6.0 6.1 6.2 7.0 8.0 9.0 APPENDIX A APPENDIX B EXECUTIVE
SUMMARY
RADIOACTIVE EFFLUENT DATA Supplemental Effluent Release Data Gaseous Effluent Data Liquid Effluent Data METEOROLOGICAL DATA MAXIMUM INDIVIDUAL DOSES Doses From Noble Gas Releases Doses From Gaseous Effluent Releases Doses From Liquid Effluent Releases OFFSITE AMBIENT RADIATION MEASUREMENTS PERCENT OF ODCM EFFLUENT CONTROL LIMITS Gaseous Effluent Releases Liquid Effluent Releases RADIOACTIVE WASTE DISPOSAL DATA OFFSITE DOSE CALCULATION MANUAL REVISIONS REFERENCES Meteorological Joint Frequency Distributions Offsite Dose Calculation Manual 5
8 8
8 9
19 20 20 22 28 34 37 37 40 43 45 46 47 68 3
Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Jan-Dec 2005 LIST OF TABLES TABLE TABLE TITLE PAGE 2.1 Supplemental Information 10 2.2-A Gaseous Effluents - Summation of All Releases 11 2.2-B Gaseous Effluents - Elevated Releases 12 2.2-C Gaseous Effluents - Ground Level Releases 14 2.3-A Liquid Effluents - Summation of All Releases 16 2.3-B Liquid Effluents 17 4.1 Maximum Doses from Noble Gas Releases During 2005 21 4.2-A Maximum Individual Organ Doses from Gaseous Effluents 23 Jan-Mar 2005 4.2-B Maximum Individual Organ Doses from Gaseous Effluents 24 Apr-Jun 2005 4.2-C Maximum Individual Organ Doses from Gaseous Effluents 25 Jul-Sep 2005 4.2-D Maximum Individual Organ Doses from Gaseous Effluents 26 Oct-Dec 2005 4.2-E Maximum Individual Organ Doses from Gaseous Effluents 27 Jan-Dec 2005 4.3-A Maximum Individual Organ Doses from Liquid Effluents 29 Jan-Mar 2005 4.3-B Maximum Individual Organ Doses from Liquid Effluents 30 Apr-Jun 2005 4.3-C Maximum Individual Organ Doses from Liquid Effluents 31 Jul-Sep 2005 4.3-D Maximum Individual Organ Doses from Uquid Effluents 32 Oct-Dec 2005 4.3-E Maximum Individual Organ Doses from Uquid Effluents 33 Jan-Dec 2005 5.0 Average TLD Exposures by Distance Zone During 2005 36 6.1 Percent of ODCM Effluent Control Limits for Gaseous Effluent 38 Releases During 2005 6.2 Percent of ODCM Effluent Control Limits for Liquid Effluent Releases 41 During 2005 7.0 Solid Waste and Irradiated Fuel Shipments 44 A-1 Joint Frequency Distribution of Wind Directions and Speeds for the 48 33-ft Level of the 220-ft Tower A-2 Joint Frequency Distribution of Wind Directions and Speeds for the 58 220-ft Level of the 220-ft Tower 4
EXECUTIVE
SUMMARY
PILGRIM NUCLEAR POWER STATION RADIOACTIVE EFFLUENT AND WASTE DISPOSAL REPORT INCLUDING METEOROLOGICAL DATA JANUARY 01 THROUGH DECEMBER 31, 2005 INTRODUCTION This report quantifies the radioactive gaseous, liquid, and radwaste releases, and summarizes the local meteorological data for the period from January 01 through December 31, 2005. This document has been prepared in accordance with the requirements set forth in the Pilgrim Nuclear Power Station (PNPS) Technical Specifications and Revision 1 of Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Material in Liquid and Gaseous Effluents from Light Water Cooled Nuclear Power Plants".
The quantity of radioactive material released from PNPS was determined from sample analyses and continuous on-line monitoring of gaseous releases from the main stack, reactor building vent, turbine building, and various decontamination facilities, and liquid releases into the discharge canal.
The quantity and volume of radioactive waste shipped offsite from PNPS for processing and burial were determined from data contained on the radwaste shipping documentation. The meteorological data were obtained from monitoring instruments located on the 220-foot meteorological tower located at Pilgrim Station.
GASEOUS EFFLUENTS Gaseous radioactive releases for the reporting period are quantified in Tables 2.2-A, 2.2-B, and 2.2-C.
Radioactive noble gases released during the period totaled 133 Curies.
Releases of radioactive iodines and particulates with half-life of greater than 8 days totaled 0.011 Curies, and tritium releases totaled 445 Curies. No gross alpha radioactivity was detected in gaseous effluents.
Noble gases released in gaseous effluents resulted in a maximum total body dose of 0.075 mrem, with a corresponding skin dose of 1.6 mrem. The release of radioactivity in gaseous effluents from PNPS during 2005 resulted in a total body dose to the maximum-exposed hypothetical individual of about 2.9 mrem from radioactive particulates, lodines, and tritium. The maximum hypothetical dose to any organ from radioactive particulates, iodines, and tritium was about 3.2 mrem. All of these maximum doses occurred to a hypothetical individual located on property under Entergy control. The maximum, hypothetical total body dose from the combined release of radioactivity in gaseous effluents was 3.0 mrem.
The maximum individual doses from gaseous radioactive effluents were compared to the applicable ODCM dose limits. Noble gas doses were less than 12% of the corresponding 10CFR50 dose objectives. Maximum doses resulting from releases of particulates, iodines, and tritium in gaseous effluents were less than 22% of corresponding 1 OCFR50 objectives.
5
LIQUID EFFLUENTS Liquid radioactive releases for the reporting period are quantified in Tables 2.3-A and 2.3-B. No liquid effluents containing radioactivity were discharged during calendar year 2005.
METEOROLOGICAL DATA Meteorological joint frequency distributions are listed in Appendix A. During the course of 2005, numerous problems were encountered with meteorological sensors and translator card electronics.
Data recovery for the entire annual period was about 67% for the 33-ft level, and 68% for the 220-ft level of the tower. The predominant wind direction was from the south-southwest, which occurred approximately 14% of the time during the reporting period. The predominant stability class was Class D, which occurred about 37% of the time during the reporting period OFFSITE AMBIENT RADIATION MEASUREMENTS Ambient radiation exposure was evaluated to complete the assessment of radiological impact on humans. A small number of thermoluminescent dosimeters (TLDs) indicated an elevation in ambient radiation exposure on Entergy property in close proximity to the station, when compared to background levels in the region. This elevation is due to nitrogen-16 contained within the plant steam system, as opposed to radioactive effluent released from the plant. The dose to the maximum-exposed member of the National Guard, who are considered members of the public even though they are within the owner-controlled area, was estimated as being about 19 mrem during 2005. There was no measurable increase during 2005 in ambient radiation measurements at the location of the nearest resident to PNPS.
COMBINED DOSE IMPACT The collective total body dose to a maximum-exposed hypothetical member of the public from radioactive gases, liquids, and ambient radiation exposure resulting from PNPS operation during 2005 was calculated as being 5.1 mrem. This amount is less than 2% of the typical dose of 300 to 400 mrem received each year by an average person from other sources of natural and man-made radiation.
Although this calculated collective dose occurs to a maximum-exposed hypothetical individual, it is also well below the NRC dose limit of 100 mrem/yr specified in 10CFR20.1301, as well as the EPA dose limit of 25 mrem/yr specified in 40CFR190. Both of these limits are to be applied to real members of the general public, so the fact that the dose to the hvyothetical maximum-exposed individual is within the limits ensures that any dose received by a real member of the public would be smaller and well within any applicable limit.
6
RADIOACTIVE SOLID WASTE DISPOSAL Solid radioactive wastes shipped offsite for processing and disposal during the reporting period are described in Table 7.0. Approximately 539 cubic meters of solid waste, containing 1785 Curies of radioactivity, were shipped during the reporting period.
CONCLUSION The PNPS Offsite Dose Calculation Manual contains effluent controls to limit doses resulting from releases of radioactivity to the environment. None of the effluent controls associated with liquid or gaseous effluents were exceeded during the reporting period, as confirmed by conservative dose assessments performed at weekly and monthly intervals. Conformance to the PNPS ODCM effluent control limits ensures that releases of radioactivity in liquid and gaseous effluents are kept as low as reasonably achievable in accordance with 10 CFR Part 50, Appendix I. Compliance with the ODCM also demonstrates that requirements of the Environmental Protection Agency's nuclear fuel cycle standard, 40CFR190.10, Subpart B, have been met. Based on the dose assessment results for 2005, there was no significant radiological impact on the general public from PNPS operation.
7
2.0 RADIOACTIVE EFFLUENT DATA Radioactive gaseous and liquid releases for the reporting period are given in the standard format presented in Tables 1A, 11B, 1C, 2A, 2B, and Supplemental Information table from NRC Regulatory Guide 1.21 (Reference 1) format.
2.1 Sunolemental Effluent Release Data Supplemental information related to radioactive gaseous and liquid releases for the reporting period are given in the standard NRC Regulatory Guide 1.21 format in Table 2.1.
2.2 Gaseous Effluent Data Gaseous radioactivity is released from Pilgrim Station to the atmosphere from the main stack, reactor building vent, turbine building, and various decontamination facilities. Combined gaseous effluent releases from all release points are summarized in Table 2.2-A. No alpha activity was detected on any of the particulate filters collected during the reporting period. The total gaseous releases for various categories of radionuclides, as well as the corresponding average release rates, can be summarized as follows:
Noble gases:
133 Ci, 4.21 igCi/sec Particulates and iodines with 0.01 08 Ci, 0.000341 p.CVsec half-life greater than 8 days Tritium:
445 Ci, 14.1 gCVsec Effluent releases from the main stack are detailed in Table 2.2-B. The main stack is 335 feet tall, and represents an elevated release point with a total height of approximately 400 feet above sea level.
The main stack is located about 700 feet west-northwest of the reactor building.
Ground-level effluent releases are detailed in Table 2.2-C. Data in this table include releases from the reactor building vent, turbine building, and assorted equipment decontamination facilities (e.g.,
hot machine shop, carbon dioxide pellet decon trailer, plastic media decon trailer, etc.) used during the period.
Due to the close proximity of the reactor building, all of these release points are considered to be mixed-mode/ground level release points.
8
2.3 Liquid Effluent Data Liquid radioactivity is released from PNPS to Cape Cod Bay via the circulating water discharge canal.
These effluents enter Cape Cod Bay at the outfall of the canal, which is located about 1100 feet north of the reactor building.
Liquid effluent releases are summarized in Table 2.3-A.
Detailed breakdowns for individual radionuclides are listed in Table 2.3-B. There were no discharges of liquid effluents containing radioactivity during the calendar year of 2005.
Total releases for the various categories of radionuclides, as well as their corresponding mean concentrations, can be summarized as follows:
Total Effluent Volume:
Total Dilution Volume:
0 Liters 0 Liters Fission/Activation products:
0 Ci, 0 gCi/mL Tritium:
O Ci, 0 pCimL Dissolved/entrained noble gases:
0 Ci, 0 gCVmL 9
Table 2.1 Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Supplemental Information January-December 2005 FACILITY: PILGRIM NUCLEAR POWER STATION LICENSE: DPR-35
- 1. REGULATORY LIMITS
- a. Fission and activation gases:
500 mrem/yr total body and 3000 mrem/yr for skin at site boundary b,c. lodines, particulates with half-life:
1500 mrem/yr to any organ at site boundary
>8 days, tritium
- d. Liquid effluents:
0.06 mrem/month for whole body and 0.2 mrem/month for any organ (without radwaste treatment)
- 2. EFFLUENT CONCENTRATION LIMITS
- a. Fission and activation gases:
I0CFR20 Appendix B Table II
- b. lodines:
10CFR20 Appendix B Table II
- c. Particulates with half-life > 8 days:
OCFR20 Appendix B Table II
- d. Liquid effluents:
2E-04 iCVmL for entrained noble gases; 10CFR20 Appendix B Table II values for all other radionuclides
- 3. AVERAGE ENERGY Not Applicable
- 4. MEASUREMENTS AND APPROXIMATIONS OF TOTAL RADIOACTIVITY
- a. Fission and activation gases:
High purity germanium gamma spectroscopy for all
- b. lodines:
gamma emitters; radiochemistry analysis for H-3,
- c. Particulates:
Fe-55 (liquid effluents), Sr-89, and Sr-90
- d. Liquid effluents:
- 5. BATCH RELEASES l
Jan-Mar l
Apr-Jun Jul-Sep l
Oct-Dec l Jan-Dec 2005 2005 2005 2005 j
2005
- a. Liquid Effluents
- 1. Total number of releases:
0 0
0 0
0
- 2. Total time period (minutes):
0 0
0 0
0
- 3. Maximum time period (minutes):
0 0
0 0
0
- 4. Average time period (minutes):
0 0
0 0
0
- 5. Minimum time period (minutes):
0 0
0 0
0
- 6. Average stream flow during periods of release of effluents Into a flowing stream 0
0 0
0 0
(Liters/min):
- 6. ABNORMAL RELEASES
- a. Liquid Effluents l
None Non one I
None l
None
Table 2.2-A Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Gaseous Effluents - Summation of All Releases January-December 2005 1
1 1
Est.
RELEASE PERIOD l Jan-Mar Apr-Jun Jul-Sep Oct-Dec Jan-Dec l Total l
2005 2005 l
2005 l
2005 2005 l Error A. FISSION AND ACTIVATION GASES Total Release: Ci
[1.62E+01 4.11 E+01 [1.66E+01 5.90E+01 1.33E+02 I Average Release Rate: uC
~sec 2.06E+00 5.21 E+00 l 2.11 E+00 7.48E+00 4.21 E+00
+/-
+22%
Percent of Effluent Control Limit*
I B. IODINE-131 Total lodine-131 Release: Ci 3.49E-04 4.1 OE-04 2.75E-04 2.85E-04 1.32E-03 Average Release Rate: uCVsec 4.43E-05 5.21 E-05 3.48E-05 3.62E-05 4.18E-05
+/-20%
Percent of Effluent Control Limit* j C. PARTICULATES WITH HALF-LIVES > 8 DAYS Total Release: Ci 1.48E-04 4.63E-04 1.63E-04 2.36E-05 7.97E-04 Average Release Rate: uC/sec 1.87E-05 5.87E-05 2.07E-05 2.99E-06 2.53E-05
+
Percent of Effluent Control Llmit*
1*
Gross Alpha Radioactivity: Ci N DA NDA NDA NDA NDA D. TRITIUM Total Release: Ci l 1.06E+02 4.06E+01 3.62E+01 2.62E+02 l 4.45E+02 l Average Release Rate: uC~sec 1.34E+01 5.16E+00 4.59E+00 3.33E+01 1.41E+01 i +/-20%
Percent of Effluent Control Limit*
Notes for Table 2.2-A:
- Percent of Effluent Control Limit values based on dose assessments are provided in Section 7 of this report.
- 1. NDA stands for No Detectable Activity.
11
Table 2.2-B Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Gaseous Effluents - Elevated Release January-December 2005 CONTINUOUS MODE RELEASES FROM ELEVATED RELEASE POINT Nuclide Released l Jan-Mar 2005 Apr-Jun 2005 Jul-Sep 2005 Oct-Dec 2005 Jan-Dec 2005
- 1. FISSION AND ACTIVATION GASES: CI Ar-41 2.95E-01 7.84E-01 9.53E-01 1.28E-01 2.16E+00 Kr-85 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 Kr-85m 2.71 E+00 3.76E+00 3.83E+00 7.26E+00 1.75E+01 Kr-87 0.00E+00 3.01 E-01 0.OOE+00 1.21 E-01 4.23E-01 Kr-88 0.00E+00 1.03E+00 9.25E-01 2.34E+00 4.30E+00 Xe-131m 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 Xe-133 6.11 E+00 1.27E+01 4.07E+00 3.61 E+01 5.90E+01 Xe-133m 0.00E+00 1.30E-01 0.OOE+00 0.00E+00 1.30E-01 Xe-135 3.76E-01 1.28E+00 1.24E-01 6.58E-01 2.44E+00 Xe-135m 0.00E+00 2.73E-01 3.1OE-01 3.30E-01 9.13E-01 Xe-137 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 Xe-138 0.00E+00 1.78E-01 0.OOE+00 6.41E-01 8.19E-01 Total for Period 9.49E+00 2.04E+01 1.02E+01 4.76E+01 8.77E+01
- 2. IODINES: Ci 1-131 8.94E-05 1.68E-04 l
6.51 E-05 4.67E-05 3.69E-04 1-133 5.78E-04 7.28E-04 4.35E-04 3.11 E-04 2.05E-03 Total for Period 6.67E-04 8.96E-04 5.00E-04 3.58E-04 2.42E-03
- 3. PARTICULATES WITH HALF-LIVES >8 DAYS: CI Cr-51 0.00E+00 1.50E-05 0.OOE+00 0.00E+00 1.50E-05 Mn-54 0.00E+00 1.16E-05 0.00E+00 0.00E+00 1.16E-05 Fe-59 0.00E+00 5.70E-06 0.00E+00 0.OOE+00 5.70E-06 Co-58 0.OOE+00 2.04E-06 0.OOE+00 0.00E+00 2.04E-06 Co-60 0.00E+00 5.31 E-06 0.00E+00 0.OOE+00 5.31 E-06 Zn-65 0.00E+00 2.14E-06 o.OOE+oo O.OOE+oo 2.14E-06 Sr-89 0.002+00 1.49E-05 0.00E+00 0.00E+00 1.49E-05 Sr-90 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 Cs-137 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 BaJLa-140 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Total for Period 0.00E+00 5.67E-05 0.00E+00 0.00E+00 5.67E-05
- 4. TRITIUM: Ci H-3 8.85E-01 6.56E-01 6.51 E-01 7.98E-02 2.27E+00 Notes for Table 2.2-B:
- 1. N/A stands for not applicable.
- 2. NDA stands for No Detectable Activity.
Fission Gases: 1 E-04 jCi/cc lodines:
1E-12 g+/-CVcc Particulates:
1 E-11 jgCVcc 12
Table 2.2-B (continued)
Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Gaseous Effluents - Elevated Release January-December 2005 BATCH MODE RELEASES FROM ELEVATED RELEASE POINT Nuclide Released J Jan-Mar 2005 Apr-Jun 2005 Jul-Sep 2005 Oct-Dec 2005 Jan-Dec 2005
- 1. FISSION AND ACTIVATION GASES: CI Ar-41 N/A N/A N/A N/A N/A Kr-85 N/A N/A N/A N/A N/A Kr-85m N/A N/A N/A N/A N/A Kr-87 N/A N/A N/A N/A N/A Kr-88 N/A N/A N/A N/A N/A Xe-131m N/A N/A N/A N/A N/A Xe-133 N/A N/A N/A N/A N/A Xe-133m N/A N/A N/A N/A N/A Xe-135 N/A N/A N/A N/A N/A Xe-135m N/A N/A N/A N/A N/A Xe-137 N/A N/A N/A N/A N/A Xe-138 N/A N/A N/A N/A N/A Total for period N/A N/A N/A N/A N/A
- 2. IODINES: Ci 1-131 N/A N/A N/A N/A N/A 1-133 N/A N/A N/A N/A N/A Total for period N/A N/A N/A N/A N/A
- 3. PARTICULATES WITH HALF-LIVES > 8 DAYS: Cl Cr-51 N/A N/A N/A N/A N/A Mn-54 N/A N/A N/A N/A N/A Fe-59 N/A N/A N/A N/A N/A Co-58 N/A N/A N/A N/A N/A Co-60 N/A N/A N/A N/A N/A Zn-65 N/A N/A N/A N/A N/A Sr-89 N/A N/A N/A N/A N/A Sr-90 N/A N/A N/A N/A N/A Cs-137 N/A N/A N/A N/A N/A Ba/La-140 N/A N/A N/A N/A N/A Total for period N/A N/A N/A N/A N/A
- 4. TRITIUM: Ci H-3 N/A N/A N/A N/A N/A Notes for Table 2.2-B:
- 1. N/A stands for not applicable.
- 2. NDA stands for No Detectable Activity.
Fission Gases: 1 E-04 pjCVcc lodines:
1 E-12 IiCi/cc Particulates:
1 E-1 1 +/-Ci/cc 13
Table 2.2-C Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Gaseous Effluents - Ground-Level Release January-December 2005 CONTINUOUS MODE RELEASES FROM GROUND-LEVEL RELEASE POINT Nuclide Released Jan-Mar 2005 Apr-Jun 2005 Jul-Sep 2005 Oct-Dec 2005 Jan-Dec 2005
- 1. FISSION AND ACTIVATION GASES: Cl Ar-41 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Kr-85 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 Kr-85m 0.OOE+00 0.OOE+00 0.OOE+00 5.29E-01 5.29E-01 Kr-87 0.OOE+00 8.65E-01 0.OOE+00 8.68E-01 1.73E+00 Kr-88 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 Xe-131m O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 Xe-1 33 5.09E-01 3.39E+00 4.85E-01 8.42E-01 5.22E+00 Xe-133m 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Xe-135 6.20E+00 2.24E+00 5.94E+00 9.10E+00 2.35E+01 Xe-135m 0.OOE+00 8.97E-01 0.OOE+00 0.OOE+00 8.97E-01 Xe-137 0.OOE+00 6.26E+00 0.OOE+00 0.OOE+00 6.26E+00 Xe-138 0.OOE+00 7.04E+00 0.OOE+00 0.OOE+00 7.04E+00 Total for period 6.71 E+00 2.07E+01 6.42E+00 1.13E+01 4.52E+01
- 2. IODINES: Ci 1-131 2.60E-04 2.43E-04 2.10E-04 l
2.38E-04 9.51 E-04 1-133 1.92E-03 1.15E-03 1.47E-03 2.05E-03 6.58E-03 Total for period 2.18E-03 1.39E-03 1.68E-03 2.28E-03 7.53E-03
- 3. PARTICULATES WITH HALF-LIVES > 8 DAYS: Cl Cr-51 0.OOE+00 8.81 E-06 0.OOE+00 0.OOE+00 8.81 E-06 Mn-54 0.00E+00 2.83E-05 0.OOE+00 0.OOE+00 2.83E-05 Fe-59 0.OOE+00 5.23E-06 0.OOE+00 0.OOE+00 5.23E-06 Co-58 0.OOE+00 3.16E-06 0.OOE+00 0.OOE+00 3.16E-06 Co-60 0.OOE+00 3.49E-05 0.OOE+00 0.OOE+00 3.49E-05 Zn-65 O.OOE+00 7.62E-05 O.OOE+00 O.OOE+00 7.62E-05 Sr-89 1.48E-04 2.25E-04 1.38E-04 0.OOE+00 5.11 E-04 Sr-90 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Cs-137 0.OOE+00 1.55E-06 0.OOE+00 0.OOE+00 1.55E-06 Ba/La-140 0.OOE+00 2.28E-05 2.49E-05 2.36E-05 7.13E-05 Total for period 1.48E-04 4.06E-04 1.63E-04 2.36E-05 7.41 E-04
- 4. TRITIUM: Cl H-3 1.05E+02 4.OOE+01 3.55E+01 2.62E+02 4.43E+02 Notes for Table 2.2-C:
- 1. N/A stands for not applicable.
- 2. NDA stands for No Detectable Activity.
Fission Gases: 1 E-04 jgCVcc lodines:
1 E-1 2 j+/-Cicc Particulates:
1 E-1 1 gCVcc 14
Table 2.2-C (continued)
Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Gaseous Effluents - Ground-Level Release January-December 2005 BATCH MODE RELEASES FROM GROUND-LEVEL RELEASE POINT Nuclide Released lJan-Mar 2005 Apr-Jun 2005 Jul-Sep 2005 Oct-Dec 2005 Jan-Dec 2005
- 1. FISSION AND ACTIVATION GASES: Cl Ar-41 N/A N/A N/A N/A N/A Kr-85 N/A N/A N/A N/A N/A Kr-85m N/A N/A N/A N/A N/A Kr-87 N/A N/A N/A N/A N/A Kr-88 N/A N/A N/A N/A N/A Xe-131m N/A N/A N/A N/A N/A Xe-133 N/A N/A N/A N/A N/A Xe-1 33m N/A N/A N/A N/A N/A Xe-1 35 N/A N/A N/A N/A N/A Xe-135m N/A N/A N/A N/A N/A Xe-137 N/A N/A N/A N/A N/A Xe-138 N/A N/A N/A N/A N/A Total for period N/A N/A N/A N/A N/A
- 2. IODINES: Ci l-131 N/A N/A N/A N/A N/A 1-133 N/A N/A N/A N/A N/A Total for period N/A N/A N/A N/A N/A
- 3. PARTICULATES WITH HALF-LIVES > 8 DAYS: Cl Cr-51 N/A N/A N/A N/A N/A Mn-54 N/A N/A N/A N/A N/A Fe-59 N/A N/A N/A N/A N/A Co-58 N/A N/A N/A N/A N/A Co-60 N/A N/A N/A N/A N/A Zn-65 N/A N/A N/A N/A N/A Sr-89 N/A N/A N/A N/A N/A Sr-90 N/A N/A N/A N/A N/A Cs-137 N/A N/A N/A N/A N/A Ba/La-140 N/A N/A N/A N/A N/A Total for period N/A N/A N/A N/A N/A
- 4. TRITIUM: CI H-3 N/A N/A N/A N/A N/A Notes for Table 2.2-C:
- 1. N/A stands for not applicable.
- 2. NDA stands for No Detectable Activity.
Fission Gases: 1 E-04 glCVcc lodines:
i E-12 pCVcc Particulates:
1 E-1 1 gCVcc 15
Table 2.3-A Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Liquid Effluents - Summation of All Releases January-December 2005 Est.
RELEASE PERIOD Jan-Mar Apr-Jun Jul-Sep Oct-Dec Jan-Dec Total 2005 2005 2005 2005 1 2005 Error A. FISSION AND ACTIVATION PRODUCTS Total Release (not including N/A N/A N/A N/A N/A tritium, gases, alpha): Ci Average Diluted Concentration N/A N/A N/A N/A N/A N/A During Period: uCVmL_
Percent of Effluent Concentration N/A N/A N/A N/A N/A Limit*__
B. TRITIUM Total Release: Ci N/A N/A N/A N/A N/A Average Diluted Concentration N/A N/A N/A N/A N/A N/
During Period:
CVmL l____l_
_l N/A N/A Percent of Effluent Concentration N/A N/A N/A N/A N/A Limit*__
C. DISSOLVED AND ENTRAINED GASES Total Release: Ci l
N/A N/A N/A N/A N/A Average Diluted Concentration N/A N/A N/A N/A N/A N/A Percent of Effluent Concentration NIA N/A N/A N/A N/A D. GROSS ALPHA RADIOACTIVITY Total Release: Ci N/A N/A N/A N/A N/A N/A E. VOLUME OF WASTE RELEASED PRIOR TO DILUTION Waste Volume: Liters N/A N/A N/A N/A N/A N/A F. VOLUME OF DILUTION WATER USED DURING PERIOD Dilution Volume: Liters N/A N/A N/A N/A N/A N/A Notes for Table 2.3-A:
- Additional percent of Effluent Control Limit values based on dose assessments are provided In Section 7 of this report.
- 1. N/A stands for not applicable.
- 2. NDA stands for No Detectable Activity.
16
Table 2.3-B Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Liquid Effluents January-December 2005 CONTINUOUS MODE RELEASES Nuclide Released Jan-Mar 2005 l Apr-Jun 2005 Jul-Sep 2005 Oct-Dec 2005 Jan-Dec 2005
- 1. FISSION AND ACTIVATION PRODUCTS: CI Cr-51 N/A N/A N/A N/A N/A Mn-54 N/A N/A N/A N/A N/A Fe-55 N/A N/A N/A N/A N/A Fe-59 N/A N/A N/A N/A N/A Co-58 N/A N/A N/A N/A N/A Co-60 N/A N/A N/A N/A N/A Zn-65 N/A N/A N/A N/A N/A Zn-69m N/A N/A N/A N/A N/A Sr-89 N/A N/A N/A N/A N/A Sr-90 N/A N/A N/A N/A N/A Zr/Nb-95 N/A N/A N/A N/A N/A Mo/Tc-99 N/A N/A N/A N/A N/A Ag-110m N/A N/A N/A N/A N/A Sb-124 N/A N/A N/A N/A N/A 1-131 N/A N/A N/A N/A N/A 1-133 N/A N/A N/A N/A N/A Cs-134 N/A N/A N/A N/A N/A Cs-137 N/A N/A N/A N/A N/A Ba/La-140 N/A N/A N/A N/A N/A Ce-141 N/A N/A N/A N/A N/A Total for period N/A N/A N/A N/A N/A
- 2. DISSOLVED AND ENTRAINED GASES: CI Xe-133 N/A N/A N/A l
N/A N/A Xe-135 N/A T
N/A N/A N/A N/A Total for period -
N/A N/A N/A T
N/A T N/A Notes for Table 2.3-B:
- 1. N/A stands for not applicable.
- 2. NDA stands for No Detectable Activity.
Strontium:
5E-08 gCVmL lodines:
I E-06 j+/-CVmL Noble Gases:
1 E-05 IiCVmL All Others:
5E-07 jxCl/mL 17
Table 2.3-B (continued)
Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Liquid Effluents January-December 2005 BATCH MODE RELEASES Nuclide Released Jan-Mar 2005 Apr-Jun 2005 Jul-Sep 2005 Oct-Dec 2005 Jan-Dec 2005
- 1. FISSION AND ACTIVATION PRODUCTS: Ci Cr-51 N/A N/A N/A N/A N/A Mn-54 N/A N/A N/A N/A N/A Fe-55 N/A N/A N/A N/A N/A Fe-59 N/A N/A N/A N/A N/A Co-58 N/A N/A N/A N/A N/A Co-60 N/A N/A N/A N/A N/A Zn-65 N/A N/A N/A N/A N/A Zn-69m N/A N/A N/A N/A N/A Sr-89 N/A N/A N/A N/A N/A Sr-90 N/A N/A N/A N/A N/A Zr/Nb-95 N/A N/A N/A N/A N/A Mo/Tc-99 N/A N/A N/A N/A N/A Ag-110m N/A N/A N/A N/A N/A Sb-1124 N/A N/A N/A N/A N/A 1-131 N/A N/A N/A N/A N/A 1-133 N/A N/A N/A N/A N/A Cs-134 N/A N/A N/A N/A N/A Cs-137 N/A N/A N/A N/A N/A Ba/La-140 N/A N/A N/A N/A N/A Ce-141 N/A N/A N/A N/A N/A Total for period N/A N/A N/A N/A N/A
- 2. DISSOLVED AND ENTRAINED GASES: Cl Xe-133 N/A N/A N/A r
N/A N/A Xe-135 N/A N/A N/A I
N/A N/A Total for period N/A NIA N/A l
N/A N/A Notes for Table 2.3-B:
- 1. N/A stands for not applicable.
- 2. NDA stands for No Detectable Activity.
Strontium:
5E-08 gCVmL lodines:
IE-06 IxClmL Noble Gases:
1E-05 gjCVmL All Others:
5E-07 gCVmL 18
3.0 METEOROLOGICAL DATA Meteorological data are summarized for the reporting period in Appendix A, in the standard joint frequency distribution format as given in NRC Regulatory Guide 1.21.
The predominant meteorological conditions observed during the annual reporting period can be summarized with their corresponding frequencies as follows:
Stability Class:
Class D, 37%
33-ft Wind Direction (from): South-southwest, 14%
33-ft Wind Speed:
3.5-7.5 mph, 54%
220-ft Wind Direction (from): South-southwest, 12%
220-ft Wind Speed:
12.5-18.5 mph, 35%
There were a number of instances when data collection from the 220-ft meteorological tower was not continuous. During the course of 2005, numerous problems were encountered with meteorological sensors and translator card electronics. Data recovery for the entire annual period was about 67%
for the 33-ft level, and 68% for the 220-ft level of the tower. These data recovery values are well below the NRC's recommended annual recovery goal of 90%. Steps have been taken to perform backups of the database computer, as well as performing qualitative data screening on a weekly basis to identify malfunctioning sensors and facilitate more timely repairs. A detailed engineering design plan is being implemented to upgrade meteorological instrumentation to increase reliability and data recovery.
19
4.0 MAXIMUM INDIVIDUAL DOSES Doses to the maximum exposed individual resulting from radionuclides in effluents released offsite were calculated using methods presented in the PNPS Offsite Dose Calculation Manual (ODCM, Reference 2), NRC Regulatory Guide 1.109 (Reference 3), NRC Regulatory Guide 1.111 (Reference 4), and the Pilgrim Station Unit 1 Appendix I Evaluation (Reference 5).
Maximum individual doses are calculated separately for: (1) noble gases in gaseous effluents, (2) particulates, iodines, and tritium in gaseous effluents; and, (3) liquid effluents. Maximum consumption and use factors for various pathways from Table E-5 of the PNPS ODCM are used for calculating the doses to the maximum exposed individual.
Information related to liquid and gaseous effluent releases are summarized Section 2 of this report.
These effluent release data were used as input to computer programs to calculate the resulting doses. PNPS ODCM methodologies were used to calculate the dose contributions to the various organs in each age class from major exposure pathways.
4.1 Doses From Noble Gas Releases Gaseous effluent release data presented in Tables 2.2-A, 2.2-B, and 2.2-C from this effluent release report were used as input to a dose assessment computer program to calculate radiation doses.
These data include gaseous releases from the PNPS main stack, reactor building vent, and turbine building roof exhausters. Meteorological data obtained from the PNPS 220-foot meteorological tower during the 10-year period from 1994 through 2003 were used as input to the uAEOWS-T3 computer program (Reference 6).
This program was used to calculate the annual average atmospheric dispersion and deposition factors used in the dose assessment computer program to calculate maximum individual doses.
The maximum individual doses resulting from radioactive noble gases released in gaseous effluents are presented in Table 4.1 according to specific receptor locations. This table includes all noble gas doses for the individual calendar quarters and total calendar year.
Noble gases released in gaseous effluents from PNPS during 2005 resulted in a maximum total body dose of 0.075 mrem. The maximum skin dose was 1.6 mrem. Both of these doses occurred to a hypothetical individual, located at the shoreline approximately 0.10 kilometers NNE of the PNPS Reactor Building. These areas are under control of Entergy Nuclear.
For the more "realistic" individuals at offsite locations, the maximum total body dose was 0.0041 mrem (nearest residence, 0.80 kilometers ESE from the Reactor Building), while the maximum skin dose was 0.023 mrem (nearest residence, 0.80 kilometers ESE from the Reactor Building).
20
Table 4.1 Maximum Doses From Noble Gas Releases During 2005(a)
Gamma Beta Total Release Air Dose Air Dose Body Dose Skin Dose Period (location)
(location)
(location)
(location)
JaM 1.OOE-02 1.40E-01 6.60E-03 1.12E-01 Jan-Mar (0.10 km NNE)
(0.10 km NNE)
(0.10 km NNE)
(0.10 km NNE) 7.28E-02 1.17E+00 4.86E-02 1.12E+00 Apr-Jun (0.10 km NNE)
(0.10 km NNE)
(0.10 km NNE)
(0.10 km NNE) 9.73E-03 1.34E-01 6.41 E-03 1.07E-01 Jul-Sep (0.10 km NNE)
(0.10 km NNE)
(0.10 km NNE)
(0.10 km NNE)
O 2.OOE-02 2.96E-01 1.33E-02 2.50E-01 Oct-Dec (0.10 km NNE)
(0.10 km NNE)
(0.10 km NNE)
(0.10 km NNE)
Jan-Dec 1.13E-01 1.74E+00 7.49E-02 1.59E+00 (0.10km NNE)
(0.10 km NNE)
(0.10 km NNE)
(0.10 km NNE)
(a) All directions and distances are with respect to the reactor building vent.
21
4.2 Doses From Gaseous Effluent Releases Gaseous effluent release data presented in Tables 2.2-A, 2.2-B, and 2.2-C from this effluent release report were used as input to a dose assessment computer program to calculate radiation doses.
These data include gaseous releases from the PNPS main stack, reactor building vent, and turbine building roof exhausters. Meteorological data obtained from the PNPS 220-foot meteorological tower during the 10-year period from 1994 through 2003 were used as input to the "AEOLUS-3" computer program (Reference 6).
This program was used to calculate the annual average atmospheric dispersion and deposition factors used in the dose assessment computer program to calculate maximum individual doses.
The maximum individual doses resulting from radioactive particulates, iodines, and tritium released in gaseous effluents are presented in Tables 4.2-A through 4.2-E. These tables cover the individual calendar quarters and the total calendar year, respectively. Doses resulting from releases of noble gases are addressed independently in the PNPS ODCM.
Therefore, none of these tables for maximum individual doses include any dose contribution from noble gases. The presentation and analysis of doses resulting from noble gases are addressed in Section 4.1 of this report.
Tables 4.2-A through 4.2-E summarize the maximum total body and organ doses for the adult, teen, child, and infant age classes resulting from the major gaseous exposure pathways. These tables present the dose data according to specific receptor location and the exposure pathways assumed to occur at that location. For example, the second column of the tables presents the information for the hypothetical maximum-exposed at the most restrictive site boundary location, where only inhalation and ground deposition exposure pathways are assumed to occur. Since this is a shoreline location controlled by Entergy, the other pathways of garden vegetable production, milk production, and meat production are assumed not to occur. Doses for other offsite locations not under Entergy control, where other exposure pathways can and do occur, are presented in subsequent columns of the tables, and represent the potential maximum doses to individuals at these locations.
Radioactivity released in gaseous effluents from PNPS during 2005 resulted in a maximum total body dose (teen age class) of 2.9 mrem. The maximum organ dose (teen age class, thyroid) was 3.2 mrem. Both of these doses occurred to hvoothetical individuals at the shoreline 0.10 kilometers NNE of the PNPS Reactor Building, an area under Entergy control. For the more "realisticM individuals at offsite locations, the maximum total body dose was 0.16 mrem (child age class at nearest garden location, 0.87 kilometers SE from the Reactor Building), while the maximum organ dose was 0.17 mrem (child thyroid at nearest garden location, 0.87 kilometers SE from the Reactor Building, yielding vegetables).
22
Table 4.2-A Maximum Individual Organ Dose at Receptor Location -- mrem From Gaseous Release Period: Jan-Mar 2005 Receptor:
Bound Resident Garden Cow/Goat Cow/Meat Meat Direction:
NNE ESE SE WSW W
S Distance':
0.10 km 0.80 km 0.87 km 3.97 km 5.77 km 3.80 km Pathway2:
Dl Dl DIV3 DIVCG3 DIVCM 3 DIVM3 Aae Class: Adult Bone 7.59E-04 1.01 E-05 4.76E-04 4.11 E-05 1.38E-05 2.90E-05 GI-LLI 6.71 E-01 7.93E-03 2.39E-02 2.77E-03 1.03E-03 1.49E-03 Kidney 6.71 E-01 7.93E-03 2.39E-02 2.77E-03 1.03E-03 1.49E-03 Liver 6.71 E-01 7.92E-03 2.38E-02 2.76E-03 1.03E-03 1.49E-03 LunI 6.73E-01 7.94E-03 2.39E-02 2.76E-03 1.03E-03 1.49E-03 Thyroid 7.34E-01 8.61 E-03 2.58E-02 3.92E-03 1.14E-03 1.64E-03 T.Body 6.71 E-01 7.92E-03 2.39E-02 2.76E-03 1.03E-03 1.49E-03 Age Class: Teen Bone 1.01 E-03 1.28E-05 7.38E-04 6.86E-05 2.11 E-05 4.41 E-05 GI-LLI 6.77E-01 8.OOE-03 2.69E-02 3.32E-03 1.12E-03 1.61 E-03 Kidney 6.77E-01 8.00E-03 2.68E-02 3.32E-03 1.12E-03 1.61 E-03 Liver 6.77E-01 8.OOE-03 2.68E-02 3.31 E-03 1.12E-03 1.61 E-03 Lung 6.80E-01 8.02E-03 2.68E-02 3.31 E-03 1.12E-03 1.61 E-03 Thyroid 7.59E-01 8.89E-03 2.87E-02 5.07E-03 1.24E-03 1.75E-03 T.Body 6.77E-01 7.99E-03 2.68E-02 3.31 E-03 1.12E-03 1.61 E-03 Aae Class: Child Bone 1.32E-03 1.63E-05 1.76E-03 1.66E-04 5.OOE-05 1.05E-04 GI-LLI 5.98E-01 7.06E-03 3.80E-02 4.94E-03 1.58E-03 2.27E-03 Kidney 5.98E-01 7.06E-03 3.80E-02 4.96E-03 1.58E-03 2.26E-03 Liver 5.98E-01 7.06E-03 3.80E-02 4.95E-03 1.58E-03 2.26E-03 Lung 6.OOE-01 7.09E-03 3.80E-02 4.94E-03 1.58E-03 2.26E-03 Thyroid 6.99E-01 8.17E-03 4.07E-02 8.40E-03 1.79E-03 2.47E-03 T.Body 5.98E-01 7.06E-03 3.80E-02 4.95E-03 1.58E-03 2.27E-03 Age Class: Infant Bone 9.86E-04 1.25E-05 8.85E-06 1.48E-04 3.24E-06 5.20E-07 GI-LLI 3.44E-01 4.06E-03 2.89E-03 3.80E-03 1.83E-04 1.66E-04 Kidney 3.44E-01 4.07E-03 2.89E-03 3.82E-03 1.84E-04 1.66E-04 Liver 3.44E-01 4.07E-03 2.89E-03 3.82E-03 1.84E-04 1.66E-04 Lung 3.46E-01 4.09E-03 2.91 E-03 3.79E-03 1.84E-04 1.67E-04 Thyroid 4.37E-01 5.09E-03 3.61 E-03 1.18E-02 4.67E-04 2.07E-04 T.Body 3.44E-01 4.06E-03 2.89E-03 3.81 E-03 1.83E-04 1.66E-04 1 Distances are measured with respect to the reactor building vent.
2 Pathway designations are as follows:
D = Deposition (Ground Plane)
I = Inhalation V = Vegetable Garden C=CowMilk G=GoatMilk M=Meat 3 Doses are conservative since it is unlikely for vegetables. to be grown outside or for animals to-be fed on pasture during winter months.
23
Table 4.2-B Maximum Individual Organ Dose at Receptor Location -- mrem From Gaseous Release Period: Apr-Jun 2005 Receptor:
Bound Resident Garden Cow/Goat Cow/Meat Meat Direction:
NNE ESE SE WSW W
S Distance':
0.10 km 0.80 km 0.87 km 3.97 km 5.77 km 3.80 km Pathway2:
Dl Dl DIV DIVCG DIVCM DIVM Age Class: Adult Bone 1.66E-02 3.43E-04 9.68E-04 7.85E-05 2.96E-05 6.28E-05 GI-LLI 2.72E-01 3.36E-03 9.50E-03 1.08E-03 4.07E-04 5.97E-04 Kidney 2.72E-01 3.35E-03 9.35E-03 1.08E-03 4.02E-04 5.86E-04 Liver 2.72E-01 3.35E-03 9.36E-03 1.07E-03 4.02E-04 5.88E-04 Lung 2.77E-01 3.41 E-03 9.36E-03 I 1.07E-03 4.01 E-04 5.85E-04 Thyroid 3.1 8E-01 3.87E-03 1.1 OE-02 2.29E-03 5.14E-04 7.48E-04 T.Body 2.71 E-01 3.35E-03 9.36E-03 1.07E-03 4.01 E-04 5.86E-04 Age Class: Teen Bone 1.69E-02 3.46E-04 1.37E-03 1.22E-04 4.15E-05 8.73E-05 GI-LLI 2.74E-01 3.39E-03 1.07E-02 1.29E-03 4.41 E-04 6.44E-04 Kidney 2.74E-01 3.38E-03 1.05E-02 1.29E-03 4.36E-04 6.33E-04 Liver 2.74E-01 3.38E-03 1.05E-02 1.29E-03 4.37E-04 6.35E-04 Lung 2.82E-01 3.48E-03 1.05E-02 1.28E-03 4.36E-04 6.33E-04 Thyroid 3.34E-01 4.04E-03 1.20E-02 3.14E-03 5.63E-04 7.75E-04 T.Body 2.74E-01 3.38E-03 1.05E-02 1.28E-03 4.36E-04 6.34E-04 Age Class: Child i
Bone 1.73E-02 3.51 E-04 2.95E-03 2.77E-04 8.84E-05 1.86E-04 GI-LLI 2.44E-01 l 3.03E-03 1.48E-02 1.91E-03 6.14E-04 8.89E-04 Kidney 2.44E-01 r 3.03E-03 1.48E-02 1.92E-03 6.13E-04 8.84E-04 Liver 2.44E-01 l 3.02E-03 1.48E-02 1.92E-03 6.15E-04 8.87E-04 Lung 2.51 E-01 J3.11 E-03 I 1.48E-02 I 1.902-03 I 6.11 E-04 I 8.82E-04 Thyroid 3.16E-01 3.83E-03 1.70E-02 5.55E-03 I 8.28E-04 l 1.09E-03 T.Body 2.44E-01 3.02E-03 1.48E-02 1.92E-03 6.15E-04 8.89E-04 Age Class: Infant Bone 1.69E-02 3.46E-04 2.41 E-04 2.45E-04 1.23E-05 1.58E-05 GI-LLI 1.47E 1.88E-03 1.33E-03 1.47E-03 7.85E-05 7.85E-05 Kidney 1.47E-01 1.88E-03 1.33E-03 1.50E-03 7.89E-05 7.86E-05 Liver 1.47E-01 1.88E-03 1.33E-03 1.50E-03 7.97E-05 7.86E-05 Lunq 1.53E-01 1.95E-03 1.38E-03 1.46E-03 7.85E-05 8.10E-05 Thyroid 2.14E-01 2.62E-03 1.86E-03 9.98E-03 3.80E-04 1.11 E-04 T.Body 1.47E-01 1.88E-03 1.33E-03 1.48E-03 7.82E-05 7.85E-05 t Distances are measured with respect to the reactor building vent.
2 Pathway designations are as follows:
D = Deposition (Ground Plane)
I = Inhalation C = Cow Milk G = Goat Milk V = Vegetable Garden M = Meat 24
Table 4.2-C Maximum Individual Organ Dose at Receptor Location -- mrem From Gaseous Release Period: Jul-Sep 2005 Receptor:
Bound Resident Garden Cow/Goat Cow/Meat Meat Direction:
NNE ESE k SE WSW W
S Distance':
0.10 km 0.80 km 0.87 km 3.97 km 5.77 km 3.80 km Pathway2:
Di Dl DIV DIVCG DIVCM DIVM Age Class: Adult Bone 6.63E-04 8.67E-06 4.45E-04 3.82E-05 1.29E-05 2.71 E-05 GI-LLI 2.28E-01 l 2.69E-03 8.15E-03 9.43E-04 3.51 E-04 5.09E-04 Kidney 2.28E-01 l 2.69E-03 8.08E-03 9.41 E-04 3.49E-04 5.05E-04 Liver 2.27E-01 l 2.68E-03 8.08E-03 9.39E-04 3.49E-04 5.05E-04 Lung l 2.29E-01 l 2.70E-03 8.09E-03 9.37E-04 3.49E-04 5.05E-04 Thyroid 2.76E-01 3.23E-03 9.63E-03 1.85E-03 4.35E-04 6.28E-04 T.Body 2.27E-01 l 2.68E-03 8.09E-03 9.39E-04 3.49E-04 5.05E-04 Age Class: Teen Bone 8.85E-04 1.11 E-05 6.91 E-04 6.36E-05 1.97E-05 4.13E-05 GI-LLI 2.30E-01 2.71 E-03 9.16E-03 1.13E-03 3.82E-04 5.51 E-04 Kidney 2.30E-01 2.71 E-03 9.08E-03 1.13E-03 3.80E-04 5.46E-04 Liver 2.29E-01 2.71 E-03 9.08E-03 1.132-03 3.80E-04 5.46E-04 Lung 2.32E-01 2.74E-03 9.1OE-03 1.12E-03 3.80E-04 5.47E-04 Thyroid 2.93E-01 3.41 E-03 1.06E-02 2.52E-03 4.77E-04 6.57E-04 2.29E-01 2.71 E-03 9.1OE-03 1.13E-03 3.80E-04 5.47E-04 Age Class: Child Bone 1.17E-03 1.42E-05 1.64E-03 1.54E-04 4.68E-05 9.79E-05 GI-LLI 2.03E-01 2.39E-03 1.29E-02 1.68E-03 5.37E-04 7.72E-04 Kidney 2.03E-01 2.40E-03 1.29E-02 1.69E-03 5.36E-04 7.69E-04 Liver 2.03E-01 2.39E-03 1.29E-02 1.68E-03 5.36E-04 7.69E-04 Lung 2.05E-01 2.42E-03 1.29E-02 1.67E-03 5.36E-04 7.69E-04 Thyroid 2.81 E-01 3.26E-03 1.50E-02 4.41 E-03 7.OOE-04 9.31 E-04 T.Body 2.03E-01 2.39E-03 1.29E-02 1.68E-03 5.37E-04 7.71 E-04 Age Class: Infant Bone 8.60E-04 1.08E-05 7.65E-06 1.36E-04 2.92E-06 4.42E-07 GI-LLI 1.17E-01 1.38E-03 9.79E-04 1.29E-03 6.22E-05 5.63E-05 KidneY 1.17E-01 1.38E-03 9.81 E-04 1.31 E-03 6.30E-05 5.64E-05 Liver 1.17E-01 1.38E-03 9.81 E-04 1.31 E-03 6.28E-05 5.64E-05 Luna 1.19E-01 1.40E-03 9.98E-04 1.29E-03 6.28E-05 5.73E-05 Thyroid 1.89E-01 2.18E-03 1.55E-03 7.67E-03 2.86E-04 8.83E-05 T
1.17E-01 1.38E-03 9.79E-04 1.30E-03 6.25E-05 5.63E-05 1 Distances are measured with respect to the reactor building vent.
2 Pathway designations are as follows:
D = Deposition (Ground Plane)
I = Inhalation V = Vegetable Garden C = Cow Milk G = Goat Milk M = Meat 25
Table 4.2-D Maximum Individual Organ Dose at Receptor Location -- mrem From Gaseous Release Period: Oct-Dec 2005 Receptor:
Bound Resident Garden Cow/Goat Cow/Meat Meat Direction:
NNE ESE SE WSW W
S Distance':
0.10 km 0.80 km 0.87 km 3.97 km 5.77 km 3.80 km Pathwaj:
Dl DI DIV3 DIVCG3 DIVCM 3 DIVM 3 Age Class: Adult Bone 3.81 E-04 5.91 E-06 7.73E-06 2.44E-06 3.26E-07 5.36E-07 GI-LLI
_1.68E+00 1.98E-02 5.96E-02 6.89E-03 2.57E-03 3.70E-03 Kidney 1.68E+00 1.98E-02 5.96E-02 6.90E-03 2.57E-03 3.70E-03 Liver 1.68E+00 1.98E-02 5.96E-02 6.89E-03 2.57E-03 3.70E-03 Lung 1.68E+00 I 1.98E-02 5.96E-02 6.89E-03 2.57E-03 3.70E-03 Thyroid 1.74E+00 2.05E-02 6.14E-02 7.89E-03 2.66E-03 3.84E-03 T.Body 1.68E+00 1.98E-02 5.96E-02 6.89E-03 2.57E-03 3.70E-03 Aqe Class: Teen Bone 4.66E-04 6.85E-06 8.31 E-06 4.12E-06 3.94E-07 5.58E-07 GI-LLI 1.69E+00 2.OOE-02 6.70E-02 8.26E-03 2.79E-03 4.01 E-03 Kidney 1.69E+00 2.00E-02 6.70E-02 8.26E-03 2.79E-03 4.01 E-03 Liver 1.69E+00 2.OOE-02 6.70E-02 8.26E-03 2.79E-03 4.01 E-03 Lng 1.69E+00 2.OOE-02 6.70E-02 8.25E-03 2.79E-03 4.01 E-03 Thyroid 1.77E+00 2.09E-02 6.87E-02 9.78E-03 2.90E-03 4.13E-03 T.Body 1.69E+00 2.OOE-02 6.70E-02 8.26E-03 2.79E-03 4.01 E-03 Age Class: Child Bone 5.73E-04 8.03E-06 1.22E-05 9.54E-06 6.96E-07 8.39E-07 GI-LLI 1.49E+00 1.76E-02 9.49E-02 1.23E-02 3.94E-03 5.64E-03 Kidney 1.49E+00 1.76E-02 9.49E-02 1.23E-02 3.94E-03 5.64E-03 Liver 1.49E+00 1.76E-02 9.49E-02 1.23E-02 3.94E-03 5.64E-03 Lung 1.49E+00 1.76E-02 9.49E-02 1.23E-02 3.94E-03 5.64E-03 Thyroid 1.60E+00 1.88E-02 9.74E-02 11.53E-02 4.12E-03 5.82E-03 T.Body 1.49E+00 1.76E-02 9.49E-02 1.23E-02 3.94E-03 5.64E-03 Age Class: Infant Bone 4.91 E-04 7.12E-06 5.01 E-06 1.88E-05 7.49E-07 3.01 E-07 GI-LLI 8.59E-01 1.01 E-02 7.21 E-03 9.47E-03 4.57E-04 4.12E-04 Kidney 8.59E-01 1.01 E-02 7.21 E-03 9.49E-03 4.58E-04 4.12E-04 Liver 8.59E-01 1.01 E-02 7.21 E-03 9.49E-03 4.57E-04 4.12E-04 Lung 8.59E-01 1.01 E-02 7.21 E-03 9.47E-03 4.57E-04 4.12E-04 Thyroid 9.53E-01 1.12E-02 7.94E-03 1.64E-02 7.OOE-04 4.52E-04 T.Body 8.59E-01 1.01 E-02 7.21 E-03 9.48E-03 4.57E-04 4.12E-04 1 Distances are measured with respect to the reactor building vent.
2 Pathway designations are as follows:
D = Deposition (Ground Plane)
I = Inhalation V = Vegetable Garden C = Cow Milk G = Goat Milk M = Meat 3 Doses are conservative since it is unlikely for vegetables to be grown outside or for animals to be fed on pasture during winter months.
26
Table 4.2-E Maximum Individual Organ Dose at Receptor Location -- mrem From Gaseous Release Period: Jan-Dec 2005 Receptor:
Bound Resident Garden Cow/Goat Cow/Meat Meat Direction:
NNE ESE SE WSW W
S Distance':
0.10 km 0.80 km 0.87 km 3.97 km 5.77 km 3.80 km Pathway2:
Dl Dl DIV3 DIVCG3 DIVCM 3 DIVM3 Age Class: Adult Bone 1.84E-02 3.68E-04 1.90E-03 1.60E-04 5.66E-05 1.19E-04 GI-LLI 2.85E+00 3.38E-02 1.01 E-01 1.17E-02 4.36E-03 6.30E-03 Kidney 2.85E+00 3.38E-02 1.01 E-01 1.17E-02 4.35E-03 6.28E-03 Liver 2.85E+00 3.37E-02 1.01 E-01 1.17E-02 4.35E-03 6.28E-03 Lung 2.85E+00 3.38E-02 1.01 E-01 1.17E-02 4.3sE-03 6.28E-03 Thyroid 3.07E+00 3.62E-02 1.08E-01 1.60E-02 4.75E-03 6.86E-03 T.Body 2.85E+00 3.37E-02 1.01 E-01 1.17E-02 4.35E-03 6.28E-03 Age Class: Teen Bone 1.93E-02 3.77E-04 2.81 E-03 2.59E-04 8.27E-05 1.73E-04 Gl-LLI 2.87E+00 3.41 E-02 1.14E-01 1.40E-02 4.73E-03 6.81 E-03 Kidney 2.87E+00 3.41 E-02 1.13E-01 1.40E-02 4.72E-03 6.79E-03 Liver 2.87E+00 3.41 E-02 1.13E-01 1.40E-02 4.72E-03 6.79E-03 Lung 2.89E+00 3.42E-02 1.13E-01 1.40E-02 4.72E-03 6.79E-03 Thyroid 3.16E+00 3.72E-02 1.20E-01 2.05E-02 5.18E-03 7.31 E-03 T.Body 2.87E+00 3.40E-02 1.13E-01 1.40E-02 4.72E-03 6.80E-03 Age Class: Child Bone 2.04E-02 3.89E-04 6.36E-03 6.07E-04 1.86E-04 3.89E-04 GI-LLI 2.54E+00 3.01 E-02 1.61 E-01 2.09E-02 6.67E-03 9.57E-03 Kidney 2.54E+00 3.01 E-02 1.60E-01 2.09E-02 6.67E-03 9.56E-03 Liver 2.54E+00 3.01 E-02 1.61 E-01 2.09E-02 6.67E-03 9.56E-03 Lunq 2.55E+00 3.02E-02 1.60E-01 2.08E-02 6.67E-03 9.55E-03 Thyroid 2.89E+00 3.40E-02 1.70E-01 3.37E-02 7.44E-03 1.03E-02 T.Body 2.54E+00 3.01 E-02 1.61 E-01 2.09E-02 6.67E-03 9.57E-03 Age Class: Infant Bone 1.92E-02 3.76E-04 2.63E-04 5.48E-04 1.92E-05 1.70E-05 GI-LLI 1.47E+00 1.75E-02 1.24E-02 1.60E-02 7.80E-04 7.12E-04 Kidney 1.47E+00 1.75E-02 1.24E-02 1.61 E-02 7.83E-04 7.13E-04 Liver 1.47E+00 1.75E-02 1.24E-02 1.61 E-02 7.84E-04 7.13E-04 Lung I 1.48E+00 1.76E-02 1.25E-02 1.60E-02 7.82E-04 7.17E-04 Thyroid 1.79E+00 2.11 E-02 1.50E-02 4.59E-02 1.83E-03 8.58E-04 T
1.47E+00 1.75E-02 1.24E-02 1.61 E-02 7.81 E-04 7.13E-04 1 Distances are measured with respect to the reactor building vent.
2 Pathway designations are as follows:
D = Deposition (Ground Plane)
I = Inhalation V = Vegetable Garden C = Cow Milk G = Goat Milk M = Meat 3 Doses are conservative since It Is unlikely for vegetables to be grown outside or for animals to be fed on pasture during winter months.
27
4.3 Doses From Liouid Effluent Releases Liquid effluent release data presented in Tables 2.3-A and 2.3-B were used as input to the dose assessment computer program to calculate radiation doses. The maximum individual doses resulting from radionuclides released in liquid effluents are presented in Tables 4.3-A through 4.3-E. These tables cover the individual calendar quarters and the total calendar year, respectively.
Tables 4.3-A through 4.3-E summarize the maximum total body and organ doses for the adult, teen, and child age classes resulting from the major liquid exposure pathways. NRC Regulatory Guide 1.109 does not recognize the infant age class as being exposed to the liquid effluent pathways.
Therefore, doses for this age class are not included in any of the tables.
It should be noted that doses calculated for the entire year might not equal the sum of the doses for the individual quarters. Doses from liquid effluents are based on the concentration (activity divided by volume) of radionuclides released in the effluent, as prescribed by the NRC in Regulatory Guide 1.109. If a larger proportion of activity is released with a relatively smaller volume of dilution water during a given quarter, the resulting concentration for that quarter will be higher than concentrations from other quarters. This will result in a proportionally higher dose for that quarter. However, when that quarters activity values are included in the annual sum, and divided by the total annual dilution flow, the resulting dose contribution will be smaller. In such a situation, the annual dose will actually be less than the sum of the individual quarterly doses.
Since there were no discharges of liquid effluents containing radioactivity, there were no dose consequences resulting from such release, and all resulting doses were zero.
28
Table 4.3-A Maximum Individual Organ Doses -- mrem From Liquid Release Period: Jan-Mar 2005 No Liquid Effluent Discharges Occurred During This Period Age Class Organ Dose - mrem
- Organ Adult Teen Child Bone O.OOE+00 0.OOE+00 0.OOE+00 GI-LLI O.OOE+00 0.OOE+00 O.OOE+00 Kidney 0.OOE+00 0.OOE+00 0.OOE+00 Liver 0.OOE+00 0.OOE+00 0.OOE+00 Lung 0.OOE+00 0.OOE+00 0.OOE+00 Thyroid 0.OOE+00 0.OOE+00 0.OOE+00 T.Body 0.OOE+00 0.OOE+00 0.OOE+00
- These doses are conservative since the same usage factor was applied for each quarter.
In reality, it is unlikely that anyone would be swimming or boating during the entire year.
However, the resulting dose is considerably lower than those from other pathways and does not contribute much to the total dose.
29
Table 4.3-B Maximum Individual Organ Doses -- mrem From Liquid Release Period: Apr-Jun 2005 No Liquid Effluent Discharges Occurred During This Period Age Class Organ Dose - mrem Organ Adult Teen Child Bone O.OOE+00 O.OOE+00 O.OOE+00 GI-LLI O.OOE+00 O.OOE+00 O.OOE+00 Kidne O.OOE+00 0.OOE+00 O.OOE+00 Liver 0.OOE+00 O.OOE+00 0.OOE+00 Lung 0.OOE+00 0.OOE+00 O.OOE+00 Thyroid 0.OOE+00 O.OOE+00 0.OOE+00 T.Body 0.OOE+00 O.OOE+00 0.OOE+00 30
Table 4.3-C Maximum Individual Organ Doses -- mrem From Liquid Release Period: Jul-Sep 2005 No Liquid Effluent Discharges Occurred During This Period Age Class Organ Dose - mrem Organ Adult Teen Child Bone 0.OOE+00 O.OOE+00 0.OOE+00 GI-LLI 0.00E+00 O.OOE+00 O.OOE+00 Kidney O.OOE+00 O.OOE+00 O.OOE+00 Liver 0.OOE+00 0.OOE+00 0.OOE+00 Lung 0.OOE+00 0.OOE+00 0.OOE+00 Thyroid 0.OOE+00 0.OOE+00 0.OOE+00 T.Body 0.OOE+00 0.OOE+00 0.OOE+00 31
Table 4.3-D Maximum Individual Organ Doses -- mrem From Liquid Release Period: Oct-Dec 2005 No Liquid Effluent Discharges Occurred During This Period Age Class Organ Dose - mrem
- Organ Adult Teen Child Bone O.OOE+00 O.OOE+00 O.OOE+00 GI-LLI O.OOE+00 O.OOE+00 O.OOE+00 0Kidney 0
.OOE+00 0.OOE+00 0.OOE+00 Liver O.OOE+00 0.OOE+00 0.OOE+00 Lung0.00E+00 0.OOE+00 0.OOE+00 Throid 0.OOE+00 0.OOE+00 0.OOE+00 T.Body 0.OOE+00 O.OOE+00 0.OOE+00
- These doses are conservative since the same usage factor was applied for each quarter.
In reality, it is unlikely that anyone would be swimming or boating during these months.
However, the resulting dose is considerably lower than those from other pathways and does not contribute much to the total dose.
32
Table 4.3-E Maximum Individual Organ Doses -- mrern From Liquid Release Period: Jan-Dec 2005 No Liquid Effluent Discharges Occurred During This Period Age Class Organ Dose - mrem
- Organ Adult Teen Child Bone O.OOE+00 O.OOE+00 O.OOE+00 GI-LLI 0.OOE+00 O.OOE+00 O.OOE+00 Kidney 0.OOE+00 O.OOE+00 O.OOE+00 Liver 0.OOE+00 O.OOE+00 0.OOE+00 Lung O.OOE+00 O.OOE+00 0.OOE+00 Thyroid 0.OOE+00 O.OOE+00 O.OOE+00 T.Body O.OOE+00 O.OOE+00 O.OOE+00
- These doses are conservative since the same usage factor was applied for each quarter.
In reality, it is unlikely that anyone would be swimming or boating during the entire year.
However, the resulting dose is considerably lower than those from other pathways and does not contribute much to the total dose.
33
5.0 OFFSITE AMBIENT RADIATION MEASUREMENTS The PNPS ODCM does not contain control limits related specifically to offsite ambient radiation exposure.
However, Regulatory Guide 1.21 (Reference 1) recommends calculation of ambient radiation exposure as part of the overall assessment of radiological impact on man.
Thermoluminescent dosimeters (TLDs) are located at 83 sites beyond the boundary of the PNPS restricted/protected area. A number of these TLDs are located within the site boundary, on Entergy property in close proximity to the station proper. The TLDs are collected on a quarterly basis and used to calculate the ambient radiation exposure in milliRoentgen (mR) over the exposure period.
These TLDs are grouped into four zones of increasing distance from the station. Average exposure values for each of these zones were calculated for each calendar quarter and the total year. The average exposure values (mR) for the four zones are presented in Table 5.0.
In addition to responding to ambient radiation exposure, TLDs will also record radiation resulting from noble gases (plume and immersion exposure), particulate materials deposited on the ground, cosmic rays from outer space, and from naturally-occurring radioactivity In the soil and air. Typically, the exposure from cosmic rays and other natural radioactivity components is about 40 to 70 mR/year. As calculated in Sections 4.1 and 4.2 of this report, the ambient radiation component of doses from PNPS effluent emissions are below 1 mrem/yr and would not be discernible above the natural radiation exposure levels.
The major source of ambient radiation exposure from PNPS results from high-energy gamma rays emitted from nitrogen-16 (N-16) contained in steam flowing through the turbine. Although the N-16 is enclosed in the process lines and turbine and is not released into the environment, the ambient radiation exposure and sky shine from this contained source accounts for the majority of the radiation dose, especially in close proximity to the station.
Other sources of ambient radiation exposure include radiation emitted from contained radioactive materials and/or radwaste at the facility. Despite these sources of ambient radiation exposure at PNPS, increases in exposure from ambient radiation are typically not observable above background radiation levels at locations beyond Entergy controlled property.
The average exposure values presented In Table 5.0 appear to indicate an elevation in ambient exposures in Zone 1, those TLDs within 2 miles of PNPS. Most of this apparent elevation is due to increases in exposure levels measured at TLD locations on Entergy property in close proximity to the station proper. For example, the annual exposure at TLD location OA, located at the Overlook Area near the PNPS Health Club (I&S Building), was 550 mR for the entire year. This location is immediately adjacent to the station proper and overlooks the turbine building, therefore receiving the highest direct ambient and sky shine exposure. When the near-site TLDs (those located within 0.6 km of the Reactor Building) are removed from the calculation of averages, the mean annual exposure in Zone 1 falls from 95.1 +/- 81.4 mR/yr to 65.2 i 11.4 mR/yr. Such a corrected dose is not statistically different from the Zone 4 average of 63.8 +/- 12.3 mR/yr, and is indicative of natural background radiation.
Although the annual exposure at TLD location OA was 486 mR above the average Zone 4 exposure, members of the general public do not continuously occupy this area.
When adjusted for such occupancy, a hypothetical member of the public who was at this location for 40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> per year would only receive an incremental dose of 2.2 mrem over natural background radiation levels. At the nearest residence 0.80 kilometers (0.5 miles) southeast of the PNPS Reactor Building, the annual exposure was calculated as being 66.1 +/- 11.1 mR (based on continuous occupancy at this location),
which compares quite well to the Zone 4 annual average background radiation level of 63.8 +/- 12.3 mR.
34
It must be emphasized that the projected ambient exposures discussed on the previous page are calculated to occur to a maximum-exposed hvoothetical individual.
Even though conservative assumptions are made in the projection of these dose consequences, all of the projected doses are well below the NRC dose limit of 100 mrem/yr specified in 10CFR20.1301, as well as the EPA dose limit of 25 mrem/yr specified in 40CFR190. Both of these limits are to be applied to real members of the general public, so the fact that the dose to the hypothetical maximum-exposed individual is within the limits ensures that any dose received by a real member of the public would be smaller and well within any applicable limit.
In 1994, Pilgrim Station opened the old training facility (I&S Building) overlooking the plant as a health club for its employees.
This site is immediately adjacent to the protected area boundary near monitoring location OA and receives appreciable amounts of direct ambient and sky shine exposure from the turbine building. Although most personnel using this facility are employees of Entergy, they are considered to be members of the public. Due to their extended presence in the facility (500 hr/yr, assuming utilization of the facility for 2 hr/day, 5 days a week, for 50 weeks/yr), these personnel represent the most conservative case in regards to ambient radiation exposure to a member of the public within the PNPS owner controlled area.
Their annual incremental radiation dose above background during 2005 is estimated as being about 6.1 mrem, based on the average exposure measured by the TLD in the building.
The exposures measured by the TLD located in the health club would also include any increase in ambient radiation resulting from noble gases and/or particulate activity deposited on the ground from gaseous releases. However, they would not indicate any internal dose received by personnel in this facility from inhalation of small amounts of PNPS-related radioactivity contained in the air.
An environmental air sampler located immediately adjacent to the health club did not indicate any PNPS-related activity during 2005. Dose calculations performed in the same manner as those outlined in Section 4.2 for airborne effluent releases yielded a projected total body dose to the maximum-exposed individual (500 hr/yr exposure) of about 0.011 mrem, resulting from inhalation.
In response to the September 11, 2001 terrorism event, access to areas in the immediate vicinity of Pilgrim Station by members of the general public has been discontinued. A number of National Guard troops have been posted at Pilgrim Station to patrol the owner-controlled areas beyond the protected area. However, since these individuals are not employees of Pilgrim Station, they are considered to be members of the public for dose assessment purposes. Considering that their location is not fixed and they are patrolling areas within the site boundary, their annual exposure was estimated based on the average of those TLDs between the protected area fence and site boundary.
The maximum dose received by a member of the National Guard is estimated to be about 18.9 mrem. Inhalation doses for National Guard troops, calculated in the same manner as that described above, were calculated at about 0.048 mrem.
Again, it must be emphasized that the above-described exposures were received by personnel who are employees or contractors of Entergy, accessing areas or facilities on property under the ownership and control of Entergy. Since this exposure was received within the owner-controlled area, it is not used for comparison to the annual dose limit of 25 mremryr specified in 40CFR190. This regulation expressly applies to areas at or beyond the owner-controlled property, and is not applicable in this situation. As stated earlier, TLDs at and beyond the site boundary do not indicate elevated ambient radiation levels resulting from the operation of Pilgrim Station.
Although some of the TLDs in close proximity to PNPS indicate increases in exposure levels from ambient radiation, such increases are localized to areas under Entergy control. For members of the general public who are not employed or contracted with Entergy and are accessing Entergy controlled areas (e.g., parking lots, etc.), such increases in dose from ambient radiation exposure are estimated as being less than 2.2 mrem/year.
35
Table 5.0 Average TLD Exposures By Distance Zone During 2005 Average Exposure +/- Standard Deviation: mR/period Exposure Zone 1
- Zone 2 Zone 3 Zone 4 Period 0-3 km 3-8 km 8-15 km
>15 km Jan-Mar 25.6 +/-22.6 15.6 +/- 2.0 16.1 +/- 1.4 16.8 +/- 1.6 Apr-Jun 21.0 +/- 15.0 13.4 +/- 1.8 13.4 +/- 1.5 14.3 +/- 1.9 Jul-Sep 26.7 +/- 22.5 18.8 +/- 2.8 18.7 +/- 2.6 19.0 +/- 2.6 Oct-Dec 22.0 +/-20.5 12.3 +/-2.1 11.3 +/-1.5 13.4 +/-2.8 Jan-Dec 95.1 +/- 81.4 59.9 +/-13.1 J 59.6 +/-13.3 63.8 +/-12.3
- Zone 1 extends from the PNPS restricted/protected area boundary outward to 3 kilometers (2 miles), and includes several TLDs located within the site boundary.
- When corrected for TLDs located within the site boundary, the Zone 1 annual average is calculated to be 65.2 +/- 11.4 mR/yr.
36
6.0 PERCENT OF ODCM EFFLUENT CONTROL LIMITS The PNPS ODCM contains dose and concentration limits for radioactive effluents. In addition, the effluent controls specified ensure that radioactive releases are maintained as low as reasonably achievable. The percentage of the PNPS ODCM Control limit values were determined from doses calculated in Section 4, the effluent releases summarized in Section 2, and the ODCM Control limits/objectives listed in Tables 6.1 and 6.2.
The percent of applicable control limit values are provided to supplement the information provided in the Section 2 of this report. The format for the percent of applicable limits is modified from that prescribed in Regulatory Guide 1.21 (Reference 1) to accommodate the Radioactive Effluents Technical Specifications (RETS) that became effective March 01, 1986. The percentages have been grouped according to whether the releases were via liquid or gaseous effluent pathways.
6.1 Gaseous Effluent Releases Dose-based effluent controls related to exposures arising from gaseous effluent releases are presented in Table 6.1. The maximum quarterly air doses and annual whole body doses listed in Table 4.1 were used to calculate the percentage values shown in Table 6.1. All doses resulting from noble gas exposure were a small percentage of the applicable effluent control.
Organ dose limits for the maximum-exposed individual from radioactive particulates, iodines, and tritium from the PNPS ODCM are also shown in Table 6.1. The maximum quarterly and annual organ doses from Tables 4.2-A through 4.2-E were used to calculate the percentages shown in Table 6.1.
The resulting organ doses from Pilgrim Station's gaseous releases during 2005 were a small percentage of the corresponding effluent control.
37
Table 6.1 Percent of ODCM Effluent Control Limits for Gaseous Effluent Releases During 2005 A.
Instantaneous Dose Rate Limit - Noble Gases PNPS ODCM Control 3.3.1.a Limit: 500 mrem/yr Total Body Dose Period Value - mremhr Fraction of Limit Jan-Dec 7.49E-02 1.50E-02%
B.
Instantaneous Dose Rate Limit - Noble Gases PNPS ODCM Control 3.3.1.a Limit: 3000 mrem/yr Skin Dose Period Value - mremlyr Fraction of Limit Jan-Dec 1.59E+00 5.30E-02%
C.
Instantaneous Dose Rate Limit - Particulates, lodines, & Tritium PNPS ODCM Control 3.3.1.b Limit: 1500 mrem/yr Organ Dose Period Value - mrem/vr Fraction of Limit Jan-Dec 3.16E+00 2.11 E-01 %
D.
Quarterly Dose Objective - Noble Gas Gamma Air Dose PNPS ODCM Control 3.3.2.a Objective: 5 mrad Gamma Air Dose Period Value - mrad Fraction of Limit Jan-Mar 1.OOE-02 2.OOE-01%
Apr-Jun 7.28E-02 1.46E+00%
Jul-Sep 9.73E-03 1.95E-01 %
Oct-Dec 2.OOE-02 4.OOE-01 %
E.
Annual Dose Objective - Noble Gas Gamma Air Dose PNPS ODCM Control 3.3.2.b Objective: 10 mrad Gamma Air Dose Period Value - mradhvr Fraction of Limit Jan-Dec 1.13E-01 1.13E+00%
38
Table 6.1 (continued)
Percent of ODCM Effluent Control Limits for Gaseous Effluent Releases During 2005 F.
Quarterly Dose Objective - Noble Gas Beta Air Dose PNPS ODCM Control 3.3.2.a Objective: 10 mrad Beta Air Dose Period Value - mrad Fraction of Limit Jan-Mar 1.40E-01 1.40E+00%
Apr-Jun 1.17E+00 1.17E+01%
Jul-Sep 1.34E-01 1.34E+00%
Oct-Dec 2.96E-01 2.96E+00%
G.
Annual Dose Objective - Noble Gas Beta Air Dose PNPS ODCM Control 3.3.2.b Objective: 20 mrad Beta Air Dose Period Value - mradhr Fraction of Limit Jan-Dec 1.74E+00 8.70E+00%
H.
Quarterly Dose Objective - Particulates, lodines, & Tritium PNPS ODCM Control 3.3.3.a Objective: 7.5 mrem Organ Dose Period Value - mrem Fraction of Limit Jan-Mar 7.59E-01 1.01 E+01 %
Apr-Jun 3.34E-01 4.45E+00%
Jul-Sep 2.93E-01 3.91 E+00%
Oct-Dec 1.77E+00 2.36E+01%
I.
Annual Dose Objective - Particulates, lodines, & Tritium PNPS ODCM Control 3.3.3.b Objective: 15 mrem Organ Dose Period Value - mremhr Fraction of Limit Jan-Dec 3.16E+00 2.11E+01%
39
6.2 Liouid EffluentReleases Liquid effluent concentration limits and dose objectives from the PNPS ODCM are shown in Table 6.2. The quarterly average concentrations from Table 2.3-A were used to calculate the percent concentration limits. The maximum quarterly and annual whole body and organ doses from Tables 4.3-A through 4.3-E were used to calculate the percentages shown in Table 6.2. Since no discharges of liquid effluent containing radioactivity occurred during 2005, all resulting concentrations, dose consequences, and fractional limits of NRC limits are zero.
40
Table 6.2 Percent of ODCM Effluent Control Limits for Liquid Effluent Releases During 2005 A.
Fission and Activation Product Effluent Concentration Limit PNPS ODCM Control 3.2.1 Limit: 10CFR20 Appendix B, Table 2, Column 2 Value Period Value - uCi/mL Fraction of Limit Jan-Mar O.OOE+00 0.OOE+00%
Apr-Jun 0.OOE+00 0.OOE+00%
Jul-Sep O.OOE+00 O.OOE+00%
Oct-Dec 0.OOE+00 0.OOE+00%
B.
Tritium Average Concentration Limit PNPS ODCM Control 3.2.1 Limit: 1.OE-03 gCi/mL Period Value - iUCi/mL Fraction of Limit Jan-Mar O.OOE+00 O.OOE+00%
Apr-Jun O.OOE+00 0.OOE+00%
Jul-Sep O.OOE+00 O.OOE+00%
Oct-Dec O.OOE+00 0.OOE+00%
C.
Dissolved and Entrained Noble Gases Concentration Limit PNPS ODCM Control 3.2.1 Limit: 2.OE-04 uCi/mL Period Value - ttCi/mL Fraction of Limit Jan-Mar O.OOE+00 O.OOE+00%
Apr-Jun O.OOE+00 O.OOE+00%
Jul-Sep O.OOE+00 0.00E+00%
Oct-Dec O.OOE+00 0.OOE+00%
41
Table 6.2 (continued)
Percent of ODCM Effluent Control Limits for Liquid Effluent Releases During 2005 D.
Quarterly Total Body Dose Objective PNPS ODCM Control 3.2.2.a Objective: 1.5 mrem Total Body Dose Period Value - mrem Fraction of Limit Jan-Mar 0.OOE+00 0.OOE+00%
Apr-Jun 0.OOE+00 0.OOE+00%
Jul-Sep 0.OOE+00 0.OOE+00%
Oct-Dec O.OOE+00 0.OOE+00%
E.
Annual Total Body Dose Objective PNPS ODCM Control 3.2.2.b Objective: 3 mrem Total Body Dose Period Value - mrem Fraction of Limit Jan-Dec 0.OOE+00 0.OOE+00%
F.
Quarterly Organ Dose Objective PNPS ODCM Control 3.2.2.a Objective: 5 mrem Organ Dose Period Value - mrem Fraction of Limit Jan-Mar 0.OOE+00 0.OOE+00%
Apr-Jun 0.OOE+00 0.OOE+00%
Jul-Sep 0.OOE+00 0.OOE+00%
Oct-Dec 0.OOE+00 0.OOE+00%
G.
Annual Organ Dose Objective PNPS ODCM Control 3.2.2.b Objective: 10 mrem Organ Dose Period Value - mrem Fraction of Limit Jan-Dec 0.OOE+00 0.OOE+00%
42
7.0 RADIOACTIVE WASTE DISPOSAL DATA Radioactive wastes that were shipped offsite for processing and disposal during the reporting period are described in Table 7.0, in the standard NRC Regulatory Guide 1.21 format.
The total quantity of radioactivity in Curies and the total volume in cubic meters are summarized in Table 7.0 for the following waste categories:
Spent resins, filter sludges, and evaporator bottoms; Dry activated wastes, contaminated equipment, etc.;
Irradiated components, control rods, etc.; and, Other.
During the reporting period approximately 65.8 cubic meters of spent resins, filter sludges, etc.,
containing a total activity of about 1,260 Curies were shipped from PNPS for processing and disposal.
Dry activated wastes and contaminated equipment shipped during the period totaled 614 cubic meters and contained 3.03 Curies of radioactivity. One shipment of irradiated components was shipped during the reporting period containing 21.6 cubic meters and 14.0 curies. The "Other" category, made up from "Hi Rad Trash" consisted of 66.4 cubic meters and 6.19 curies.
No shipments of irradiated fuel were made during the reporting period.
Estimates of major radionuclides, those comprising greater than 1% of the total activity in each waste category shipped, are listed in Table 7.0. There were 13 shipments to Oak Ridge, TN (Duratek); 3 shipments to Memphis, TN (RACE); and 12 shipments to Erwin, TN (Studsvik) and 1 shipment to Diversified Scientific Services, Inc.
43
Table 7.0 Pilgrim Nuclear Power Station Effluent and Waste Disposal Report Solid Waste and Irradiated Fuel Shipments January-December 2005 A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not Irradiated fuel)
- 1. Estimate of volume and activity content by type of waste Jan-Dec 2005 Type of waste Volume - m j
Curies Total Error
- a. Spent resins, filters, filter sludge's, 6.58E+01 1.26E+03
+/- 25%
evaporator bottoms, etc.
- b. Dry activated waste, contaminated 6.14E+02 3.03E+00
+/- 25%
equipment, etc.
- c. Irradiated components, control rods, etc.
2.16E+01 1.40E+01
+/-25%
- d. Other (describe): *HI Rad" Trash 6.64E+01 6.19E+00
+/-25%
- 2. Estimate of major nuclide composition by type of waste' Type of waste Radionuclide Abundance Total Error
- a. Spent resins, filters, filter sludge's, Mn-54 2.81%
+/- 25%
evaporator bottoms, etc.
Fe-55 79.0%
+/- 25%
Co-60 7.54%
+/- 25%
Cs-137 8.94%
+/- 25%
- b. Dry activated waste, contaminated Mn-54 4.56%
i 25%
equipment, etc.
Fe-55 87.6%
+/- 25%
Co-60 6.72%
+/- 25%
- c. Irradiated components, control rods, etc.
Mn-54 1.33%
+/- 25%
Fe-55 56.4%
+/- 25%
Co-60 37.6%
+/-25%
NI-63 4.31%
+/- 25%
- d. Other (describe):.Hi Rad" Trash Mn-54 2.46%
+/- 25%
Fe-55 90.2%
+/- 25%
Co-60 6.43%
0
+/-25%
IMajorjis defined as anyradionuclide comprising >1% of the totalactivityin the waste category.
- 3. Solid Waste Disposition Number of Shipments l
Mode of Transportation l
Destination Tractor-trailer
- Duratek, 13 (Hittman Transport Services)
Oak Ridge, TN Tractor-trailer RACE, '
(RACE LogisticsLLC)
Memphis, TN Tractor-trailer Studsvik,'
(Hittman Transport Services)
Erwin, TN 2
Tractor-trailer Studsvik,;'
(R&R Trucking)
Erwin, TN 1
Tractor-trailer Diversified Scientific Services, Inc.
(Priority Transport)
Kingston, TN This processor provides volume reduction services for dry compressible waste, contaminated equipment, etc. Remaining radioactive wastes will be shipped to Chem Nuclear Systems, Inc. in Bamwell, SC, or Envirocare, Inc. in Clive, UT for final disposal.
B. IRRADIATED FUEL SHIPMENTS & DISPOSITION Number of Shipments I
Mode of Transportation I
Destination None I
N/A I
N/A 44
'ANW, 8.0 OFFSITE DOSE CALCULATION MANUAL REVISIONS The PNPS Offsite Dose Calculation Manual (ODCM) was not revised during the calendar year of 2005. Information regarding revisions to the ODCM can be found attached as Appendix B of this report.
45
9.0 REFERENCES
- 1. U.S. Nuclear Regulatory Commission, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water Cooled Nuclear Power Plants", Regulatory Guide 1.21, Revision 1, June 1974.
- 2.
"Pilgrim Nuclear Power Station Offsite Dose Calculation Manual", Revision 9, June 2003.
- 3. U.S. Nuclear Regulatory Commission, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10CFR50 Appendix I", Regulatory Guide 1.109, Revision 1, October 1977.
- 4. U.S. Nuclear Regulatory Commission, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents In Routine Releases from Light-Water-Cooled Reactors",
Regulatory Guide 1.1 11, July 1977.
- 5. Boston Edison Company, "Pilgrim Station Unit 1 Appendix I Evaluation", April 1977.
- 6. Entech Engineering Inc., P100-R19, OAEOLUS A Computer Code for the Determination of Atmospheric Dispersion and Deposition of Nuclear Power Plant Effluents During Continuous, Intermittent and Accident Conditions in Open-Terrain Sites, Coastal Sites and Deep-River Valleys" 46
APPENDIX A Meteorological Joint Frequency Distributions TABLE TABLE TITLE PAGE A-1 Joint Frequency Distribution of Wind Directions and Speeds for the 48 33-ft Level of the 220-ft Tower A-2 Joint Frequency Distribution of Wind Directions and Speeds for the 58 220-ft Level of the 220-ft Tower 47
Table A-i Joint Frequency Distribution of Wind Directions and Speeds For the 33-ft level of the 220-ft Tower Jan-Mar 2005 Class A Freq: 0.074 mphI N jNNEJ NE JENEI EESE jSE JSSEJ S ISSWI SW IWSWIW WNWJ NW INNWITOTALI Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 1
0 0
0 3
0 0
1 0
0 0
0 0
0 0
0 56 3.5-7.5 11 9
5 1
0 0
3 1
0 1
1 1
2 5
13 14 67 7.5-12.5 6
4 1
0 8 I1 0
0 2
0 0
2 4
5 10 4 47 12.5-18.5,3 0
0 0
0 0
0 0
0 0
0 0
1 0
0 1
5 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0
-0 0
0 0
0 TTL 21 1 3 T 6 I
1 1
J 3 2
=
1 1131 7 (101 231 191 124 Class B Freq: 0.045 mph_
N NNEI NE ENE1E1ESE jSE S SEj S JSSWj SW JWSWj W JWNWJ NW INNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 1
0 0
0 2
0 0
0 0
0 0
0 1
1 0
0 5
3.5-7.5 4
8 0
0 1
1 0
0 0
0 0,3 2
4 5
7 35 7.6-12.5 3
2 0
2 14 1
0 0
2 0
0 1
1 6
1 1
34 12.5-18.5.0 0
0 0
1 0
0 0
0 0
0 0
0 0
0 0
1 1
8.5-,24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL r8 101012 1812 10 0121010 4 44111 6 7
Class C Freq: 0.042 mph N
N E EE E
EE SE SE S-W~
N NW NWTOA Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
0 0
1 0
0 0
0 0
0 2
0 1
1 5
3.5-7.5 6
6 3
0 0
1 0
0 2
0 1
1 2
8 1
2 33 7.5-12.5 3
1 0
1 4
1 1
0 3
0 0
1 7
2 4
1 29 12.5-18.5. 0 0
0 0
1 0
0 0
1 0
0 0
2 0
0 0
4 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
J
~1 5_liT 1311016 471 Class D Freq: 0.383 mph jN INNE INE IENEIEIESEI SE S SEJ S SSWj SW IWSW I WIWNW I NW I1NWITOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 2
3 1
1 1
2 2
4 4
1 0 6
5 3
7 2
6 59 3.5-7.5 1 3 1
5 7
6 1 5 16 13 8
1 0
1 1 5
48 68 25 23 0 288 7.5-12.5 3
1 5 8
4 1 1 9
8 1
1 7 1 1 1 3 1 6 68 48 27 8 267 12.5-18.5.0 1
3 3
2 0
0 0
7 3
0 0
6 2
0 0
27 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
00
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TTL 18 134 19 I-7 23 13 38 135 24 67 1143 82 52 2
4 48
Table A-i (continued)
Jan-Mar 2005 Class E Freq:
0.377 mph N
EEN S
[ESS ISSW SWIWWW WN NWNN TOTAL Calm-0.95 0
0 0
0 000 0
0 0
0 0
0 0
0 0
0 0.95-3.5 4
6 25 14 411 6
7 10 15 7
7 9
4 102 3.5-7.5 7
22 10 6
6 5
4 13 8
15 52 126 73 32 18 12 409 7.5-12.5 0
13 1
0 00 1
015 26 1
7 28 21 6
0 119 12.5-18.5 0
0 0
0 000 0
0 0
0 0
0 1
0 0
1 18.5-24 0
0 0
0 00 0
00 0
01 0
0 0
0 0
0
>24 0
0 0
00000L0 0
01 0
0 0
0 0
0 TOTAL j1[4 13 J11[7J1 24129[
48 1 631 148 (1081 61 1 33 6[631 Class F Freq:
0.071 mph JN NNE NEENE E E 1
WSW JW WNWINWI NNW[TOTAL Calm-0.95 0
0 0
0 000 0
0 0
0 0
0 0
0 0
0 0.95-3.5 0
1 OiOOT0 1
1 1
2 6
4 2
0 1
21 3.5-7.5 0
0 02 00 1
0 1
14 33 17 5
4 2
0 79 7.5-12.5 0
0 0
0 000 0
0 5
13 0
0 0
0 0
18 12.5-18.5 0
0 00 0
00 00 0
0 0
0 0
0 0
0 18.5-24 0
0 0
000 0
10 0
0 0
I0 0 j0 0
0
>24 0
0 00000 0
0 0
0 0
0 0
0 0
0 TOTAL J0 1
301 2
1 j2j241 23191 6 2
1 118 Class G Freq:
0.008 mph jN NNE jNE IENE EL ESE SE SSE S JSSW JSWj WSW wJ WNW jNW jNNWI TOTAL Calm-0.95 0
0 00 0
00 0
0 0
0 0
0 0
0 0
0 0.95-3.5 0
0 0
0 000 0
0 0
0 0
0 0
0 0
0 3.5-7.5 0
0 0
0 000 0
0 1
4 2
0 0
0 0
7 7.5-12.5 0
0 0
0 000 0
0 0
16 0
0 0
0 0
6 12.5-18.5 0
0 0
0 000 0
0 0
0 0
0 0
0 0
0 18.5-24 0
0 0
0000 0
0 0
0 0
0 0
0 0
0
>24 0
0 00 00 0
0 0
0 0
0 0
0 0
0-TOTAL 0 1 0 0[0 Jw 1 I10
=
0
-1 Class All Freq:
1.000 mph N
N NIEEIEIEES SSE JS I SSWISW IWSW IW I WNW JNWj NNWI TOTAL Calm-0.95 0
0 0
0 000 0
0 0
0 0
0 0
0 0
0 0.95-3.5 8
10 37 77717 1711 8 18 26 17 17 12 12 197 3.5-7.5 41 60 25 1522 2321 2221 42 96 196 150 78 62 44 918 7.5-12.5 15 35 10 737 1210 139 42 33 27 108 82 48 14 520 12.5-18.5 3
1 3
3 4
00 0
8 3
0, 0
9 3
0 1
38 18.5-24 0
0 0
0 000 0 0 0
0 0
0 0
0 0
0
>24 0
0 00 000 0 0 0
0 0
0 0
0 0
0 TOTAL
[671 106_ 141 J 32 1701 42 1381 40 1791 105 1147J1 249 J24180 J122 (71 1673 49
Table A-i (continued)
Apr-Jun 2005 Class A Freq: 0.220 mph N INN-NEIENi EI ESE SE SS ST SSW SW IWSWI W WNW NW NNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 4
4 1
2 1
1 1
0 0
0 1
0 0
0 1
2 18 3.5-7.5 14 9
5 4
2 2
6 3
8 16 3
1 2
3 6
23 107 7.5-12.5.13 11 2
0 0
1 5
3 20 38 12 0
0 0
0 3 108 12.5-18.5 9 3
1 0
0 0
0 0
0 0
0 0
0 0
0 1
14 18.5-24 2
1 0
0 0
0 0
0 0
0 0 j0 0
0 0
0 3
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTL 2 61I I
3T 4I 1 I~~
16 1 j27
]29j 250 Class B Freq: 0.033 mp N NNE NE ENE ETESE ISE TSSEI S TSSWI'SW TWSW W TWNWI NW NNW TOTALI Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 2
0 0
0 0
0 0
0 0
1 1
0 1
0 0
0 5
3.5-7.5 1
1 4
0 1
1 0
0 0
1 0
0 0
1 0
6 16 7.5-12.5 0
1 3
2 0
0 1
0 7
1 0
0 0
0 0
1 16 12.5-18.5 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 1
1 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 00 L 3L1321712111111 10711101 0 8 38 Class C Freq: 0.051 Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 1
1 0
0 0
0 0
0 1
1 0
1 0
0 0
3 8
3.5-7.5 5
0 2
i1 0
0 1
1 0
3 0
0 0
i l
O 15 7.5-12.5 0
1 0
1 0
0 1
0 8
13 2
1 0
i i
i 30 12.5-18.5 2 0
0 0
0 0
0 0
3 0
0 0
0 0
0 0
5 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0 -0 0
0 0
TOTAL 18 2
20 2 2 1
12 17 2 2 2
0 2
ri 58 Class D Freq: 0.299 mph I N JNNEj NE JENE E
ESEj SE SSEj S ISSWj SW fWSWJ W JWNWj NW JNNW TOTAL Oalm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 6
2 3
1 4
4 9
3 9
4 3
12 3
5 4
4 76 3.5-7.5 3
5 7
16 9
8 11 8
15 24 15 12 2
4 4
7 150 7.6-12.5 0
1 10 3
0 1
8 3
10 49 16 4
0 1
3 0
109 12.5-18.5 1
0 0
0 0
0 0
0 1
1 1
0 0
0 0
1 5
18.6-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOA 08120120 j13 13121431835 12815101 50
Table A-I (continued)
Apr-Jun 2005 Class E Freq: 0.303 mph INNEN ENE E
IE ESEj SE JSSEj S SS SW WSW W WNWNW[W NNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 6
1 5
4 2
2 9
9 11 10 5
7 5
1 1
3 81 3.5-7.5 5
6 5
22 16 0
5 6
10 22 26 22 16 4
3 3
171 7.5-12.5 1
1 0
0 0
0 0
0 0
60 31 0
0 0
0 0
93 12.5-18.5 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
00 24 0 0
00 0 0
0 0
0 0
0 0
0 0
0 0
0 TOTAL I1 2 8
1 0 26 18 2
1 4 1 5 21 92 '62 29 21 51 4
6 345 Class F Freq:
0.071 mph I
N EEEEEES S
SWS S
NIN N
OA Calm-0.95 0
0 0
1 0
0 0
0 0
0 0
0 0
0 0
0 1
0.95-3.5 00 1
0 0
1 1
1 0
0 2
6 4
1 0
0 17 3.5-7.5 01 0
4 0
0 0
0 0
8 12 7
3 0
2 0
37 7.5-12.5 00 0
0 0
0 0
0 0
1 1 1 3 1
0 0
0 0
25 12.5-18.5 0 0
0 0
0 0
0 0
0 0
1 0
0 0
0 0
1
- 18.
5-240 0 0
000 0
0 0
0 0
0 0
0 0
0 0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOA 1
1 IL0 1'L 1
19 2-811 72 0181 Class G3 Freq: 0.023 mph N. I NE NE E~ I S EISESSWS S
N NW JNNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
0 0
0 0
0 0
0 0
1 2
0 0
0 3
3.5-7.5 0
0 0
0 0
0 0
0 0
2 6
1 1
0 0
0 10 7.5-12.5 0
0 0
0 0
0 0
0 0
4 9
0 0
0 0
0 13 12.6-18.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
O_
0 0
0 0
000 0
0 0
0 TOTAL 10 0
01001010 0J0[ 6115 [213 [00 1 0026 Class All Freq: 1.000 mph NINEN N
S ESESSWIS WW NIN N
OA Calm-0.95 0
0 0
1 0
0 0
0 0
0 0
0 0
0 0
0 1
0.95-3.5 19 8
10 7
7 8
20 13 21 16 12 27 15 7
6 12 208 3.5-7.5 28 22 23 47 28 11 23 18 33 76 62 43 24 13 16 3950W 7.5-12.5 14 15 15 6
0 2
15 6
45 176 83 6
0 2
4 5 394 12.5-18.5.12 3
1 0
0 0
0 0
4 1
2 0
0 0
0 3
26 18.5-24 12 1
0 00 0
0 0
0 0 101
-0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
T0ALT75 49 1 49 161521158137 'gm 2915976392226rz 13 51
Table A-i (continued)
Jul-Sep 2005 Class A Freq:
0.187 mph N
N EEEEESE SE[SSE[S[SSW SW WSI W WWI NW NW I OTAL Calm-0.951 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0.95-3.5 4
5 3
7 7
2 2
2 0
0 1
1 1
2 5
2 44 3.5-7.5 1
18 1
9 11 5
3 4
19 14 3
7 1
0 1
1 96 7.5-12.5 0
0 0
0 0
0 0
0 6
13 2
0 0
0 0
0 21 12.5-18.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0 J0 0
24 0
0 0
0 00 0
0 0
0 0
0 0
0 0
0 0
TOTAL I 21 ~4 1618 7 5 161251271 618121216131161 Class B Freq: 0.033 mph N
N EIEEEEES S
S WISIWWWN N
OA Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 1
0 0
0 0
4 2
3 0
0 0
0 0
0 0
0 10 3.5-7.5 0
0 1
0 0
0 0
0 0
4 1
0 1
1 1
0 9
7.5-12.5 0
0 0
0 0
0 0
0 2
7 0
0 0
0 0
0 9
12.5-18.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
18.5-24 0L 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOA0i0 i
I0 4f2I3f2I1fi1 0 11 I112 Class C Freq: 0.045 mph jN INNEl NE 1ENE1EESE jSE I SSEJ S J SSWI SW IWSWI W IWNWI NW INNjTOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
0 0
0 0
3 3
0 0
0 0
0 0
1 7
3.5-7.5 0
0 0
0 1
2 0
1 4
14 2
0 0
0 1
0 25 7.5-12.5 0
0 0
0 0
0 0
0 1
6 0
0 0
0 0
0 7
12.5-18.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL IO[010I0Ii 0I4 8I20I2 101 0L2W Iff 39 Class D Freq: 0.227 mph ININNE NE ENE E ESEI SEISSE SISSWI SWIWSW WIWNW NWINNWITOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 2
4 1
2 1
6 11 5
5 4
2 3
¶ 2
2 3
54 3.5-7.5 0
0 3
2 1
7 1
4 11 43 15 7
3 2
2
¶ 102 7.5-12.5 0
1 0
0 0
0 0
0 5
25 6
0 0
0 0
0 37 12.5-18.5 0
0 0
0 0
0 0
0 1
1 0
0 0
0 0 W 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0:10 0
0 0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL I2 5 4 j4 2
13 11219 122 173 23 j101 4 14 I 4[9 52
Table A-i (continued)
Jul-Sep 2005 Class E Freq:
0.276 mph N NNE NE 'ENE E
SSW SW 1 WSW W IWNWI NW jNNW TOTL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 1
0 0
0 1
0.95-3.5 10 2
1 1
1 1
12 6
14 5
4 15 5
8 5
1 91 3.5-7.5 5
2 0
0 0
2 0
5 11 29 35 35 6
1 2
3 136 7.5-12 2.5 0
0,0 000 0
0 0
0 8
1 0
0 0
0 0
9 12.5
-18.650 00 000 0
0 0
0 0
0 0
0 0
0 0
0 18.5-24 0
0 00 0
0 0
0 0
0 0
0 0
0 0
0
>24 0
0 0
0 0
00 0 0
0 0
0 0
0 0
0 TOTA JI i
I_1113 1121111251421 41012191 7
Class F Freq:
0.194 Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 3
1 1
1 2
3 7
13 12 9
3 17 21 6
6 2 107 3.5-7.5 1
0 0
0 0
0 0
0 4
10 25 10 0
0 1
25 7.5-12.5 0
0 0
0 0
0 0
0 0
4 3
0 0
0 0
0 7
12.5-18.5 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0 -10 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL 14 11 11 1J2 3J7[ 13 111331127 21 21617141167 Class G Freq: 0.037 mph-I N
EEEE EES S
SWIS SIWI IN N
OA Calm-0.95 0
0 0
0 0
0 0
0 1
0 0
0 0
0 0
0 1
0.95-3.5 0
0 0
0 0
0 0
1 0
2 0
11 8
1 0
0 23 3.5-7.5 0
0 0
0 0
0 0
0 0
2 3
0 0
0 0
0 5
7.5-12.5 0
0 0
0 0
0 0
0 0
0 3
0 0
0 0
0 3
12.5-18.5 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOA 010 0 010 010 1 i 1 4
6 11118 1 10 0
32 Class All Freq:
1.000 mph N
N EEEE EES S
S SW WS WWN N
OA Calm-0.95 0
0 0
0 0
0 0
0 1
0 0
0 1
0 0
0 12 0.95-3.5 20 12 6
11 11 16 34 33 34 20 10 47 36 19 18 9
336 3.5-7.5 7
18 5
11 13 16 4 14 49 116884 59 11 4
8 7
426 7.6-12.5 0
1 0
0 0
0 0
0 14 63 15 0
0 0
0 0
93 12.5-18.5 0 0
0 0
0 0
0 0
1 1
0 0
0 0
0 0
2 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL [2713111112212413213814 99~ I2001 09106I 48123126 116 1859 53
Table A-i (continued)
Oct-Dec 2005 Class A Freq:
0.036______________
mph N INNE N ENE E
SE S
SSEj S SSW I SW jWSWI W IWNWI NW NNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 1
0 0
0 0
0 0
0 0
0 0
0 1
0 2
3.5-7.5 2
1 3
1 2
2 1
0 0
1 0
2 9
24 20 3
71 7.5-12.5 0
0 0
0 0
0 0
0 0
1 0
0 2
1 1
1 6
12.5-18.5 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
00
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
00 TOTAL 12 [1 4
f2 1100 10 12 1111251224 7
Class B Freq: 0.036 mph N1L NE1E EN~5~E 1 ESE SE SS S
WISIWININ N
OA Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
1 0 i1 0
0 0
0 0
0 0
0 0
1 2
0 5
3.5-7.5 1
0 2
i1 0
1 2
0 0
4 5
7 11 7
3 1
45 7.5-12.5 0
0 0
0 0
0 0
0 1
5 0
0 10 0
2 12 30 12.5-18.5 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 00 0
0 0
0 0
0 0
0 0
0 0
0 1]TL 1 I2f 2 1121 011 95 7 121 8
780 Class C Freq: 0.051 mph TN 'NN T
NE 1 ENE E ESE~
SE rSSE S ISW SW 1WSW W WWNW NWTOA Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 1
0 0
2 1
0 0
3 0
1 1
0 1
2 0
2 14 3.5-7.5 7
1 2
2 0
0 1
0 0
13 7
12 17 5
3 1
71 7.5-12.5 0
0 0
0 0
0 0
4 0
6 0
2 7
3 3
0 25 12.6-18.5 0
0 0
0 0
0 0
0 0
1 1
0 0
0 0
0 2
18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>.24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Class D Freq: 0.436 mph N
WISW W WWN N
OA Calm-0.95 0
0 0
0 0
0 0
0 0
1 1
0 0
0 0
0 2
0.95-3.5 3
6 7
6 14 4
1 7
4 9
14 17 8
11 7
10 128 3.5-7.5 18 22 24 13 21 17 15 12 15 74 40 80 96 64 40 17 568 7.5-12.5 2
9 12 9
6 11 6
15 9
47 8
9 56 30 19 2.250 12.6-18.5 0 2
6 0
0 0
0 0
1 0
3 0
0.-2 0
0 14 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0l 0 0
00 0
0 0
TOTAL [2339 49128 41 321221 34 129 1 131 166 1 10611601 1071 66 j29J 962 54
Table A-i (continued)
Oct-Dec 2005 Class E Freq: 0.333 mph N
NEN EN E
S SW WS W
WNWI NW NWTTL Calm-0.95 0
0 0
0 0
0 1
1 0
1 0
0 1
0 0
1 5
0.95-3.5 27 19 8
5 6
7 9
21 19 18 23 28 21 9
5 3 228 3.5-7.5 0
3 15 15 17 4
10 29 13 43 54 123 88 21 8
¶ 444 7.5-12.5.0 0
4 3
4 4
1 6
5 8
2 10 2
4 1
0 54 12.5-18.5 0 0
0 0
0 1
3 0
0 0
0 0
0 0
0 0
4 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOA 27122127123 2
161241 57J3 10 7911611112 34 1
5 735 Class IF Freq: 0.092 mph I N
E EE E ES E SE S SW S WS W WNW W NNWTOTAL Calm-0.951 0
1 01 0 0
0 0
0 0
1 0
0 1
2 0
0 5
0.95-3.5 0
1 1
1 5
2 3
8 4
8 1 2 24 7
5 3
0 84 3.5-7.5 10 0
0 0
¶ 1
0 5
5 1 2 49 33 1
0 0
0 107 7.5-12.5 0
0 0
0 0
0 0
0 0
0 6
1 0
0 0
0 7
12.5-18.5 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
00
>24 0
0 0
0 0
0 00 0 0
0 0
0 0
0 0
0 TOTAL I0 2
1 1
133 9 21 67 58 93 Class G Freq: 0.016 mph j
NE N
ENEM~
E ESELSESSEI S ISSWISWIWSW WIWNWINWINNW TOTAL Oalm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
1 0
0 1
0.95-3.5 0
0 0
0
¶ 1
2 2
1 3
9 6
4 1
0 0
30 3.5-7.5 0
0 0
0 0
0 0
0 0
0 3
0 0
0 0
0 3
7.5-12.5 0
0 0
0 0
0 0
0 0
0 0
1 0
0 0
0 1
12.5-18.5 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
-0 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0- 0 0
0 0
0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 TOTAL 0
0 1
22 31 312 7
14 2
003 Class All Freq: 1.000 mph iN NNEINE ENE E ESE SE ES1SESW SSWJWSW IWwI W WNW NW NW[TOT-AL Calm-0.95 0
I 0
0 0
0 1
1 0
3 1
0 2
3 0
1 13 0.95-3.5 31 27 17 15 27 14 15 41 28 39 59 75 41 29 18 15 491 3.5-7.5 28 27 48 32 41 25 29 48 33 147 158 257 222 121 74 23 1309 7.5-12.5 2
9 16 12 10 15 7
25 15 67 16 23 77 38 26 15 373 12.5-18.5 0
2 6
0 0
1 3
0 1
1 4
0 0
2 0
0 20 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL j61 661851 59, 78 55 s
113177125712381355 j342 1 1931118 ~I20 55
Table A-i (continued)
Jan-Dec 2005 Class A Freq: 0.104 mph_ IN NEl NE IENEIEJ ESEJ SE jSSEJ S jSSW SW IWSWI W7JWNWI NW NNW I TOTALI Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 9
9 5
9 11 3
3 3
0 0
2 1
1 2
7 4
69 3.5-7.5 28 35 14 15 15 9
13 8
27 32 7
11 14 32 40 41 341 7.5-12.5 19 15 3
0 8
2 5
3 28 52 14 2
6 6
11 8
182 12.5-18.5. 12 3
1 0
0 0
0 0
0 0
0 0
1 0
0 2
19 18.5-24 2
1 0
0 0
0 0
0 0
0 0
0 0
0 0
0 3
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL 170163123 24 34 14 2 1 J14 12L 84123 14122140158 I55 614 Class B Freq: 0.038 mph N INNE NE JENEl I ESE1I SE ISSEJ S jSSWJ SW JWSWJ W JWNW~ NW 1NNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 4
1 0
1 2
4 2
3 0
1 1
0 2
2 2
0 25 3.5-7.5 6
9 7
1 2
3 2
0 0
9 6
10 14 13 9
14 105 7.5-12.5 3
3 3
4 14 1
1 0
12 13 0
1 11 6
3 14 89 12.5-18.5 0 0
0 0
1 0
0 0
0 0
0 0
0 0
0 1
2 18.5-24 0_
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TTL13r1311016 j19[8J j
3 12 1231 7 11 2721
[1 29 2
Class C Freq: 0.048 mph jN INNE NE ENEIEIESEJ SE SSE SISSWI SW IWSWI W IWNWI NW INNWITOTAL Calm-0.95 00 00 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0.95-3.5 2
1 0
2 1
1 0
6 4
2 1
1 3
2 1
7 34 3.5-7.5 18 7
7 3
1 3
2 2
6 30 10 13 19 14 6
3 144 7.5-12.5 3
21 0 2
4 1
2 4
12 25 2
4 14 6
8 2
91 12.5-18.5. 2 0
0 0
1 0
0 0
4 1
1 0
2 0
0 0
11 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOA 25 jl 6 5 4112126158 J14118138 J22 15 12j 280 Class D Freq:
0.364 mph_
N INNE El NE I ENEIE I ESE SE JSSEj S ISSWI S WW WjWNWJ NW I NNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 ~0 1
1 0
0 0
0 0
2 0.95-3.5 13 15 12 10 20 16 23 19 22 27 25 37 15 25 15 23 317 3.5-7.5 34 42 41 37 46 48 40 32 51 152 75 145 167 95 69 34 1108 7.5-12.5 5
26 30 16 17 21 22 19 41 132 43 29 124 79 49 10 663 12.5-18.5 1
3 9
3 2
0 0
0 10 5
4 0
6 4
0
¶ 48 18.5-24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTL[3[186j92[ 66 J85 851851 70112-41317114812111-3121203113316812138 56
Table A-1 (continued)
Jan-Dec 2005 Class E Freq:
0.332 mph N
NNElNE ENE E
ESE SE SEI S SSW SW WSWI W lWN NWINNWlTOTAL Calm-0.95 0
0 0
0 0
0 1
1 0
1 0
0 2
0 10 1
6 0.95-3.5 47 28 16 15 10 14 34 47 50 40 42 65 38 25 20 11 502 3.5-7.5 17 33 30 43 39 11 19 53 42 109 167 306 183 58 31 19 1160 7.5-12.5 1
14 5
3 4
4 2
6 20 102 35 17 30 25 7
0 275 12.5-18.5 0
0 0
0 0
1 3
0 0
0 0
0 0
1 0
0 5
18.5-24 0
0 0-0 0
0 0
0 00
-0 0
0 0
0-0 0
>24 00000000 0
0 0
0 TOTAL l65 l7551 l61 l53 l301 59 107 1121 252 l 244l 388 l 0253]
l J1 58 l3 1948 Class F Freq:
0.097 mph N
NNE lNEENEl E ESElSElSSE S SSWlSWlWSW W.WNWNW NNW TOTAL Calm-0.95 0
1 0
1 0
0 0
0 0 1 0
0 1
2 0
0 6
0.95-3.5 3
3 3
3 7
6 12 23 17 18 19 53 36 14 9
3 229 3.5-7.5 1
1 0
6 1
1 1
5 10 44 119 67 9
4 5
2 276 7.5-12.5 0
0 0
0 0
0 0
0 0
20 35 2
0 0
, 0.
0 57 12.5-18.5 0
0 0
0 0
0 0
0 0
0 1
0 0
0 0
0 1
18.5-24 0
0000000000 0
0 0
0 0
0
>24 0
0 0
0 0000000 0
0 0
0 0
0
=
_=
_~~=
=
_-=
=
=
.==
=
TOTAL
[4 5
3 10 8
7 13 28 127 [ 83 1174!
122 146120 14 l5 l
569 Class G Freq:
0.018 mph lN NNE INEENEIE lESElSElSSEl S lSSWlSWlWSWl W [WNW NWlNNWlTOTAL Calm-0.95 0
0 0
0 0 0
0
° 0
1 0
0 0
0 1
0 0
2 0.95-3.5 l
0 0
0 1
1 2
3 1
5 9
18 14 2
0 0
56 3.5-7.5 0
0 0
0 0 00 0
06 3
1 0
0 0
25 7.5-12.5 0
0 0
0 0
0 0
0 0
4 1 8
1 0
0
, 0 0
23 12.5-18.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
18.5-24 0
0 0
0 0
0j 0
0 01 0 01 0
10 0
0 0
0
>24 0
0 00 0
0 0
0 00 0
0 0
0 0=
0 0
0 0
TOTAL 1
1 2
3 2
14 43 22 15 3106 Class All Freq:
1.000 mph lN NNE lNEENE E ESElSElSSE S SSWlSWlWSW W WNW INWNNW TOTAL Calm-0.95 0
1 0
1 0
1 1
1 3
1 0
3 3
0 1
16 0.95-3.5 78 57 36 40 52 45 76 104 94 93 99 175 109 72 54 48 1232 3.5-7.5 104 127 99 105 104 75 77 100 136 381 400 555 407 216 160 113 3159 7.5-12.5 31 60 41 25 47 29 32 32 113 348 147 56 185 122 78 34 1380 12.5-18.5 15 6
10 3
4 1 3
0 14 6
6 0
9 5
0 4
86 18.5-24 2
1 0
0 0
0 0 0
0 0
0 0
0 0
0 0
3
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL l 2301 252 11861 174 1 207 1 150 l189l 237 lj358 831 l 653
=
418 2
200 5876 l 57
Table A-2 Joint Frequency Distribution of Wind Directions and Speeds For the 220-ft level of the 220-ft Tower Jan-Mar 2005 Class A Freq:
0.085 mph N
NE NE IENE E EE SE SS ISW I5W JWSWI W JWNWI WJNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
3.5-7.5 1
1 2
0 0
1 1
0 0
0 0
0 0
0 0
1 7
7.5-12.5 4
5 7
1 2
2 0
0 0
0 0
0 0
1 4
2 28 12.5-18.5 4 2
1 3
0 1
6 1
0 2
1 1
0 4
7 12.45 18.5-24 0
0 0
0 3
3 0
0 1
0 0
1 0
2 1-39 3
>24 11 3
0 0
5 0
0 0
0 1
5 3
1 4
TOA 20 11110141101 7 11 21 21117 Class B Freq:
0.044 mph jN JNNE jNE jENEj E ESE SE jSSE I J
SSWj SW IWSW1 W IWNWI NW JNNW [TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
3.5-7.5 2
1 1
0 2
0 0
0 0
0 0
0 0
0 0
0 6
7.5-12.5 1
2 2
0 0
1 0
0 0
0 0
0 0
3 3
3 115 12.5-18.5 0 5
1 0
1 1
0 0
0 0
0 2
1 2
4 3
20 18.5-24 0
1 0
2 5
2 0
0-0 2
0 0
1 2
3 3
21
>24 2
0 0
0 8
1 0
0 0
0 0
0 0
2 1
3 17 TOTAL 5[
145101 0J 2
22 911 1
Class C Freq: 0.040 mph jN [ NNE INE I1ENE EI JESEI SE SSE J S SSWJ WJWSWJ W JWNWI NW INNWITOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
3.5-7.5 0
2 1
0 1
0 1
0 0
0 0
0 0
2 1
0 8
7.5-12.5 0
1 4
0 0
2 0
0 0
0 0
0 0
1 2
2 12 12.5-18.5 1
2 0
1 0
0 1
0 1
4 I
2 1
5 1
3 23 18.5-24 3
1 0
0 3
1 0
0 0
0 0
0 0
3 3
1 15
>24 0
0 0
0 2
0 1
0 0
1 0
0 3
3 1
4 15 TOTAL 14 161 11613131 0~ 1 5~ Ij2 4 11418 II Class D Freq: 0.374 mph_[ N INNE JNE ENE1E1ESE SE SS5E1 5 SW! SW JWSWI W IWNWI NW INNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
0 0
1 0
0 0
0 0
0 0
0 1
0 2
3.5-7.5 8
6 6
1 2
5 0
5 0
1 2
1 5
3 1
4 50 7.5-12.5 7
6 7
6 5
19 5
11 5
6 4
10 13 9
7 5
115 12.5-18.5 8
9 7
8 10 10 17 3
9 13 19 17 40 33 13 7
223 18.55-24 1
8 3
1 7
3 5
0 3
7 5
1 38 46 41 11 180
>24 0
4 1
6
'5 3
1 2
0 2
0 0
15 36 16 7 108 TTL 24 33 124122 29] 31128121 17139130 29111111127 791 34 678 58
Table A-2 (continued)
Jan-Mar 2005 Class E Freq:
0.376 mph N
N EEEEEES S
SWS S I WI WNW JNWI NNW [TOTAL Calm-0.95 0
0 0
0 000 0
0 0
0 0
0 0
0 0
0 0.95-3.5 1
2 1
120 0
10 0
0 0
1 4
1 0
14 3.5-7.5 2
5 7
10 656 2
6 3
3 3
4 7
6 9
82 7.5-12.5 4
0 11 3
3 7
14 8
7 6
7 13 21 19 8
5 136 12.5-18.5 3
15 4
0 I
3 5
4 7
4 18 47 70 44 17 13 255 18.5-24 2
6 3
0 0
0 11 0
2 17 15 9
37 27 15 16 150
>24 1
7 00 00 010 1
5 0
0 0
12 12 7
45 TOTAL [13135 2W 14~ 121 24 115231 35 1 :3]
72 11331 113 ]59JS0 682 Class F Freq:
0.072 mph
[N NN N--EEEEES S
SWS WSWFWWWN N
TOTAL Calm-0.95 0
0 0
0 00 00 0
0 0
0 0
0 0
0 0
0.95-3.5 1
1 0
10 00 1
0 0
0 0
0 0
0 0
4 3.5-7.5 1
2 22 00 1
0 2
1 4
1 2
3 1
1 23 7.5-12.5 1
0 0
0 0
1 0
0 1
4 4
6 4
10 I
5 37 12.5-18.5 0
1 00 0
00 0
1 2
6 17 5
6 5
3 46 18.5-24 0
00 0000 0
02 11 80000 21
>24 00 00 0
0 000 00 00000 0
TOTAL 3
4 T
37_ 0]
1 4
9 25 32 119131 Class G Freq:
0.008 mph JN NNE tNEIENE I EESE SEISSEISISSW SWI WSW Wj WNW jNWJ NNWJ TOTAL Calm-0.95 0
0 0
0 00 0
00 0
0 0
0 0
0 0
0 0.95-3.5 0
0 0
0 00 0
00 0
0 0
0 0
0 0
0 3.5-7.5 0
0 00 0
00 0 0 0
0 0
0 0
1 0
1 7.5-12.5 0
0 00 0
00 0
1 0
0 0
1 0
0 0
2 12.5-18.5 0
0 00 0
00 0
1 0
1 0
2 0
0 0
4 18.5-24 0
0 00 0
00 0 0 0
3 4
0 0
0 0
7
>24 0
0 00 0
010 000 1
0 0
0 0 10 1
TOTAL o
0 X. 1 1 5
Z1 4 1 3iTL 11JI1T15 Class All Freq:
1.000 mph N
NNE NEEEEEEIESE S
WWSF7WWWN N
OA Calm-0.95 0
0 0
0 000 0
0 0
0 0
0 0
0 0
0 0.95-3.5 2
3 12 2
10 2 0 0
0 0
1_
4 2
0 20 3.5-7.5 14 17 19 13 11 11 7
7 8
5 9
5 11 15 10 15 177 7.5-12.5 17 14 31 10 102219 1914 16 15 29 39 43 251 22 345 12.5-18.5 16 34
.13 12
.12.
15
- 29.
8 19 25 46 86 119 94 47 41 616 18.5-24 6
16 6
3 118 9
61 0 6
28 34 23 76 80 75 40 42-6
>24 14 14 11612014 2
5 I 1 18 1
0 1 9 58 33 32 228 TOTf AL~ 691 98 1 71[ 46 1731 62 1631J41 1481 92 1105t 143 J26-5(294 11921 1501 1812 59
Table A-2 (continued)
Apr-Jun 2005 Class A Freq: 0.195 mph N JNNE N
ENE[EIESE SE I SSEJI S ISSWI SW IWSWI W
=N N
NN
=OA Calm-0.95 2
8 0
0 0
0 0
0 0
0 0
0 0
0 3
7 20 0.95-3.5 0
0 0
0 0
1 0
0 0
0 0
0 0
0 1
1 3
3.5-7.5 5
5 7
0 2
0 1
0 0
0 0
0 0
1 1
1 23 7.5-12.5 2
2 4
1 1
1 2
2 0
1 4
1 1
0 1
1 24 12.5-18.5.13 2
1 0
0 0
7 2
6 8
14 11 7
3 0
9 83 18.5-24 7
3 1
0 3
0 9
5 4
10 4
3 8
0 0
3860
>24 18 6
0 1
1 0
0 0
0 0
0 0
0 0
0 5
31 TOTL 13-2 21 I
10J 191 2 15 1614T6 1271 244 Class B Freq: 0.034 mph N
N E EE E EE SE SE S SW S S I W1 IWNWI NW NNWTOTL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 1
3 4
0.95-3.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
3.5-7.5 3
0 3
0 0
0 0
0 0
0 1
1 1
0 0
0 9
7.6-12.5 1
1 2
0 0
0 0
1 0
0 0
0 0
0 0
1 6
12.5-18.5 0 1
2 4
0 0
3 0
4 3
1 0
1 0
0 0
19 18.5-24 0
0 0
0 0
0 0
0 0
1 0
0 0
0 1
1 3
>24 1
0 0
0 0
0 0
0, 0
0 0
0 0
0 0
0 1
TOTAL 6
7 4
0 0
1 4
4 2 T 1
2 2
42 Class C Freq: 0.049 mph I N INNEI NE ENE EESEI SE JSSEJ S ISSW I SW IWSWI W IWNWI NW JNNW[TOTAL Calm-0.95 4
0 0
0 0
0 0
0 0
0 0
0 0
0 2
2 8
0.95-3.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
3.5-7.5 1
1 1
0 0
0 0
0 0
1 0
1 0
0 0
2 7
7.5-12.5 0
1 1
1 0
0 0
0 0
1 0
0 0
0 0
0 4
12.5-18.5 0
0 0
2 0
0 1
0 1
12 2
1 2
0 0
0 21 18.5-24 0
1 0
0 0
0 1
0 1
3 5
0 2
1 1
0 15r
>24 3
0 0
0 0
0 0
0 3
0 0
0 0
0 0
0 6
AJ8312 131010121 0 5j 1717 i 2141113 42...61.~L Class D Freq: 0.322 Calm-0.95 5
1 0
1 1
3 1
1 1
5 2
1 2
3 8
1 36 0.95-3.5 1
2 1
4 2
0 0
0 a
2 0
1 0
1 0
0 14 3.5-7.5 2
6 4
2 3
3 3
1 2
3 1
0 1
1 4
1 37 7.5-12.5 3
2 3
1 7
4 7
11 6
23 9
6 4
1 4
1 92 12.5-18.5.
1 4
10 13 3
2 12 5
8 24 11 8
18 3
3 4
129 18.5-24 1
0 3
1 0
0 3
3 2
14 14 5
15 1
0 3065
>24 6
2 0
0 0
0 2
1 1
4 6
0 5
0 0
3 30 TOTAL 19 17121122 16 12 28 12212 7J4~215 10 I19 J 0
60
Table A-2 (continued)
Apr-Jun 2005 Class E Freq:
0.306 mph
[NI NNE INE ENEJEJIESE ISEI SSE IjS jSSW SW~ WSW W
WNW INW I NNW [TOTAL Calm-0.95 8
10 3
0 2
0 0
0 0
0 3
1 0
0 2
1 30 0.95-3.5 0
2 2
2 TT 0
0 T
1 0
0 0
1 0
1 12 3.5-7.5 1
3 3
3 16 43 5
4 1
3 3
0 2
1 53 7.5-12.5 1
1 0
6 10 15 10 9
9 7
8 7
14 9
8 2
116 12.5-18.5 2
2 0
0 3
0 3
5 3
4 11 13 19 6
3 0
74 18.5-24 1
1 0
0 002 10 10 35 8
8 1
0 4
71
>24 0
1 1
00 0
0 5
10 3
6 0
0 1
27 TOTAL T3 20 19 1
271 22 1191 18118 [ 31
[ 681 35 1 0[
17 1 15] 1) 383 Class IF Freq:
0.074 mph N~
NNE NE ENE~
I S
WNWj NW]I NNW TOTAL Calm-0.95 0
0 0
0 100 1
2 1
0 0
0 5
0.95-3.5 0
1 2
10 00 0
0 1
1 0
0 0
0 0
6 3.5-7.5 1
0 0
0 3
0 0
0 0
2 1
2 11 7.5-12.5 0
0 o
T 13 0
1 2
1 2
2 2
3 3
20 12.5-18.5 1
1 0
0 00 1
0 0
0 6
6 5
2 1
0 23 18.5-24 0
0 10 0
0 00 0
0 1
3 3
3 4
3 4
21
>24 0
0 0
0 000 0
0 0
4 1
1 0
0 0
8 TOA21 j
j
~
1 12 2
4-5 ~17 13 11 0
=
-9 Class (3 Freq:
0.021 mph N
JNNE NE ~ENE Ej ESE SE ISS SSWI SWIWSWIWIWNWINW I NNW TOT AL Calm-0.95 0
0 00 0
00 0
0 0
0 0
0 0
0 0
0 0.95-3.5 0
0 0
0 000 0
0 0
0 0
0 0
0 0
0 3.5-7.5 0
0 0
0 000 0
0 0
0 0
0 0
2 1
3 7.5-12.5 0
0 0
0 000 0
0 0
1 3
0 0
0 1
5 12.5-18.5 0
0 0
0 000 0
0 0
0 2
2 4
1 0
9 18.5-24 0
0 0
0 000 0
0 0
1 1
1 2
2 0
7
>24 0
0 00 00 0
0 0]02 0
0 0
0 0
2 TOTAL 0o 0
01001 0101 01010 J16 316151 2 26 Class All Freq:
1.000 mph
[N NNE NE LENE EI ESE I SE ISSE I S j~SSW jSW~ WSW JWJ WNWJNW I NNWJ TOTAL Calm-0.95 19 19 3
13 3
2 1
1 6
7 3
2 3
161 14 103 0.95-3.5 1
5 57 32 0
0 1
4 1
1 0
2 1
2 35 3.5-7.5 13 15 18 517 108 4
108 3
5 5
4 10 8
143 7.5-12.5 7
7 10 9
19 23 19 23 16 34 23 19 21 12 16 9
267 12.5-18.5 17 10
.13 19 6
2 27,12
.22.
51 45 41 54 18 8
13 358 18.5-24 9
5 4
130 15917 139 62 i20 3
9 7
15 242
>24 28 9
TTT4 F
9 122 4
2 0
0 9
103 TOTAL [1~
70 1 43521 40 173I 5 0 [611 151 1 163 93 11311 48 jo 701 125 61
Table A-2 (continued)
Jul-Sep 2005 Class A Freq: 0.187 mph N
N~NEjNEENE I EESE SE SSEj S ]SSWjI SW jWSWJ W jWNWJ NW INNWITOTALI Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 1
2 0
0 1
1 0
1 0
0 0
0 0
0 0
0 6
3.5-7.5 2
1 4
6 6
3 3
4 1
1 0
0 0
1 1
0 33 7.5-12.5 5
1 0
1 5
7 8
4 8
6 5
1 4
0 1
2 58 12.5-18.5. 4 6
0 0
0 3
0 1
5 20 7
1 1
1 0
1 50 18.5-24 7
2 0
0 0
0 0
0 0
3 0
0 1
0 0
1 14
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOA 9
1214 7 121 14111 1101141 30 1121216 21 161Tie Class S Freq: 0.033 mph [N NNE[ NE jENEJ EESE SE JSSEI S SS5W SW jWSW~ W JWNWJ NW INNWITOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.96-3.5 0
0 0
0 0
0 1
0 0
1 0
0 0
0 0
0 2
3.5-7.5 0
0 0
0 0
1 1
1 0
0 0
0 0
0 0
0 3
7.5-12.5 1
0 0
0 0
1 1
0 1
2 0
0 0
1 0
0
.7 12.5-18.5.
1 0
1 0
0 0
0 0
0 3
2 0
0 1
0 1
9 18.5-24 0
0 0
0 0
0 0
0 0
5 2
0 0
0 0
0 7
>4 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 TOTAL 2 J 1
J 0 0J 2 13 1 1
11 4 0 I
1 28 Class C Freq: 0.04S mph jN JNNEJ NE ENEIEIEE SE_ SSEJ S SSWj SW JWSWj W IWNWJ NW I NNW ITOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 1
3.5-7.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
7.5-12.5 0
0 0
0 2
4 0
1 2
0 0
0 0
0 0
0 9
12.5-18.5 0
0 0
0 0
1 0
2 1
10 6
0 0
0 0
1 21 18.5-24 0
0 0
0 0
0 0
0 0
6 2
0 0 10 10 10-18
- .24 0
0 0 ~O0 0
0 0
0 0
0 0
0 0
0 0
0 TOTAL 1
0 01021 +/-LI2 L3L3 6I5 I 10101010 2
39 Class D Freq: 0.227 mph N jNNE NE IENE E IESEI SE SSEJ S jSSWJ SW JWSWJ WIWNWI NW jNNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
2 0
0 0
1 0
0 1
1 0
0 0
0 0
0 5
3.5-7.5 0
1 2
2 2
1 0
2 1
3 0
0 0
0 0
0 14 7.5-12.5 2
0 1
0 2
4 10 10 4
6 1
1 3
3 0
2
.49 12.5-18.5 1
3 0
0 0
4 0
4 2
25 19 5
4 3
1 2
73 18.5-24 1
2 0
0 0
0 0
0 5
19 19 0
0 0
0 2
4
>24 0
1 0
0 0
0 0
0 3
2 0
0 0
0 0
0 6
TOA I4
~
2 4~
lj I 10 16 161566 39 6J7[6 11 61 195 62
Table A-2 (continued)
Jul-Sep 2005 Class E Freq:
0.276 mph
[N NNE INEIENEIEIESEISEISSE I SSSWISWI WSW IWI WNW NW NNWj TOTAL Calm-0.95 0
0 0
0 0
0 00 000 0
0 0
0 0
0 0.95-3.5 0
1 01 00 01 0
00 0
0 0
0 0
3 3.5-7.5 3
1 4
2 23 4
3 1
2 0
0 0
0 1
27 7.5-12.5 5
¶ 10 12 56 57 1
3 10 6
6 2
51 12.5-18.5 6
0 0
1 3
1 2
10 7
18 12 1 1 112 18 5
1 107 18.5-24 7
1 030 0
01 06113 4
4 2
1 2
44
>24 1
0 00 00 00 0
00 0
10 0
2 2
5 TOA 22 4
5 7
6 16Ilr 21 11 33
-27 16 26 U 1418 1237 Class F Freq:
0.194 mph I NI NNNE INIENEI EI ESE ISEISSEISLSSWISWIWSW IWI WNW NW INNWj TOTAL Calm-0.95 0
0 00 00 00 0
00 0
0 0
0 0
0 0.95-3.5 0
0 01 00 1
00 00 0
0 0
0 0
2 3.5-7.5 1
0 0
1 0223 22 1
1 1
1 2
2 21 7.5-12.5 5
2 1
0 1
1147 3
62 4
0 7
9 7
69 12.5-18.5 2
0 0
1 0
1T 11 2
410 5
12 4
4 3
60 18.5-24 3
0 01 00 02 02 3
1 1
0 02 15
>24 0
0 0
00 00 0
000 0
0 0
0 0
0 TOTAL 111j2 1 4 1 4 18123]71 14 J 16 [ 11 1 141 12 1 15J 14 1167 Class G Freq:
0.037 mph I N INNE INEI ENE IE I ESE jISE J SSE ISjISSW ISWj WSW WI WNW NW I NNW TOTAL Calm-0.95 0
0 0
0 00 0
00 0
0 0
0 0
0 0
0 0.95-3.5 0
0 2
0 0
T11h0 0
0 0
0 0
0 0
4 3.5-7.5 2
1 0
0 002 12 0
0 0
0 0
0 2
10 7.5-12.5 0
0 00 0
0 012 2
0 1
0 0
3 0
9 12.5-18.5 0
0 0
00 0
000 0
1 5
0 0
0 3
9 118.55-24 0
0 00 00 0
00 0
0 0
0 0
0 0
0
>24 0
0 00 00000 0
0 0
0 0
0 0
0 Class All Freq:
1.000 mph INj NNE INEJENEIEIESEISEJSSEISI SSW ISWJ WSW WI WNW jNW I NNW ITOTAL Calm-0.95 0
0 0
0 10 0
00 0
0 0
0 01 0
0 0
0 0.95-3.5 1
5 2
2 13 3
2 2
0 0
0 0
0 1
23 3.5-7.5 8
4 1011 10 1012 147 8
2 1
1 2
3 5
108 7.5-12.5 18 4
3 1
11 19 38 29 25 29 9
10 7
17 19 13 252 12.5-18.5 14 9
1 2
3 10 3
28 17 80 57 27 29 27 10 12 329 18.5-24 18 5
0 4
0 0
0 3
5 41 39 5
6 2
1 7
136
>24 1
1 0
0010 03 2
0 0
10 0
2 2
11 TOTAL [601 2 61 015 42 1561 76 1581 162 11071 43 14148 J 3514 85 63
Table A-2 (continued)
Oct-Dec 2005 Class A Freq: 0.035 mph I NIN NE JENEIE ESEI SEJ SSEJ S SSWI SW WSWj WJ WNWJ NW JNNWJ TOTALI Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
3.5-7.5 1
0 3
0 1
0 0
0 0
0 0
0 0
1 0
0 6
7.5-12.5 0
0 1
0
¶ 2
1 0
0 1
0 0
5 7
4 1
23 12.5-18.5.
0 0
0 0
1 0
0 0
0 0
0 0
3 10 9
1 24 18.5-24 0
0 0
0 0
0 0
0 0
1 0
0 1
2 6
2 12
>24 0
0 0
0 0
0 0
0 0
0 0
0 1
2 1
0 4
TOTAL [1 101410 3 2J1 10102 0 10110 122 120 I6 Class B Freq: 0.030 mph jN INNEINE IENEIEIESEI SE jSSEI S jSSWJ SW IWSWI W JWNWI NW JNNW ITOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
1 0
0 0
0 0
0 0
0 0
0 0
0 0
0 1
3.5-7.5 0
0 3
0 0
0 0
0 0
1 0
0 0
3 0
0 7
7.5-12.5 0
0 0
1 0
0 0
1 0
3 3
5 1
2 1
0 17 12.5-18.5 0
0 0
0 0
0 2
0 0
5 0
1 6
4 0
1 19 18.5-24 0
0 0
0 0
0 0 10 j0 12 10 10 13 13 13 10 1 1
>'24 0
0 0
0 0
0 0
0 10 0
0 3
1 1
11 0
5 TTLL0 1 1 311101 0 2 IOI 11 13 1 6 113113 15 1i 60 Class C Freq: 0.053 amph.9 0
N 0
E 0
N 0
0 S
0 E
0 S
0 0
0S 0
0W 0W 0
0W 0W 0N OA 0.95-3.95 1
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 1
3.5-7.5 0
0 0
5 0
1 0
2 1
3 2
1 1
2 1
0 19 7.5-12.5 0
0 1
0 0
0 0
0 0
5 3
9 3
2 1
0 24 12.5-18.5 0
1 0
0 0
0 0
1 0
8 4
4 8
3 2
0 31 18.5-24 4
0 0
0 0
-0 0
3 0
1 0
0 2
3
~
~1 2
1
>24 2
0 0
0 0
0 0
1 0
0 3
0 3
3 3
0 15 TTL7111115 I0 1 [0(7 1 117 12117 1318 2i i106 Class D Freq: 0.448 mph N 'NNE NE 'ENE E
SE SE SS SSWI SW WSW1 W WNW1 NW NWTOA Calm-0.951 0 0
0 0
0 0
0 0
0 0
0 0
0~
0 0
0 0
0.95-3.5 2
1 6
1 1
0 1
0 1
1 1
1 2
0 1
0 19 3.5-7.5 1
0 7
3 4
7 2
4 0
41 10 6
5 1
5 2
61 7.5-12.5 1
4 7
0 11 6
1 5
6 24 15 23 23 10 6
11 159 12.5-18.5 10 9
20 2
7 7
8 7
11 52 40 32 41 41 27 14 328 18.5-24 12 11 0
4 6
6 4
23 4 124 19 5
39 25 22 0
203
>2 10 5
16 5
5 4
1 2
5 8
1 18 20 15 3
123 TOTAL 1 311 32... 34124111 1 68 1128197176 139 893 64
Table A-2 (continued)
Oct-Dec 2005 Class E Freq:
0.328 mph N
NEl NEIENEISEESE SE SSEj S ISSW I SW jWSWI W IWNWj NW INNW TOTAL Calm-0.95 0
1 0
0 0
0 0
0 0
0 0
0 0
0 0
0 1
0.95-3.5 0
1 0
1 1
0 1
1 0
0 3
2 0
1 0
0 11 3.5-7.5 0
1 3
2 4
2 4
4 2
4 4
6 3
0 2
0 41 7.5-12.5 3
4 6
2 1
4 8
9 13 10 17 6
14 17 2
2 118 12.5-18.5 23 15 10 3
3 0
4 20 11 16 25 41 64 45 13 5 298 18.5-24 3
1 2
15 3 0
0 18 5
6 28 11 20 23 8 1 144
>24 0
0 0
19 5
4 4
0 1
1 2=! 0 0
1 5
0 4
TOTAL [29 23 2
2 1 101211521321 37 79 66 11011871 30 Class F Freq: 0.088 mph [
NNE I NE ENE IE IESE SE SSE SW SW SWI IWNWI NW INNWI.TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
1 1
1 0
1 1
0 0
1 1
2 0
0 9
3.5-7.5 0
0 0
1 0
1 2
2 5
5 5
2 3
1 2
0 29 7.5-12.5 2
0 0
0 0
0 0
3 4
9 6
6 3
9 5
1 48 12.5-18.5 0 0
0 0
0 0
0 6
4 0
5 12 10 6
1 2
46 18.5-24 0
0 0
0-0 0
0 6
0 3
13 15 4
2 0
0 43
>24 0
0 0
0 0
0 0
0 0
0 1
0 0
0 0
0 1
0 AL 0
jO 2
11 212 1181141171301361211201 8j 3 17 Class G Freq: 0.018 Calm-0.95 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0.95-3.5 0
0 0
0 0
0 0
0 0
0 0
0 1
1 0
1 3
3.5-7.5 0
1 0
1 0
0 1
1 1
2 4
1 4
0 0
0 16 7.5-12.5 0
0 0
0 0
0 0
2 3
2 6
1 0
0 0
0 14 12.5-18.5 0 0
0 0
0 0
0 0
0 0
0 0
1 1
0 0
2 18.5-24 0
0 0
I 0
0 0
0 0
0 0
0 0
0 0
0 0
>24 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
TOTAL 1011101I1 010111 3I4 41101216 1210K-1 35 Class All Freq: 1.000
-mph I INEINE ENES E IESE SE SSE S ISSW SW WSWI W WNW NW NNW ITOTAL Calm-0.95 0
1 0
0 0
0 0
0 0
0 0
0 0
0 0
0 1
0.95-3.5 3
3 6
3 3
1 2
2 2
1 4
4 4
4 1
1 44 3.5-7.5 2
2 16 12 9
1 1 9
13 9
19 25 16 16 8
10 2
179 7.5-12.5 6
8 15 9
13 12 10 20 26 54 50 50 49 47 19 15 403 12.5-18.5 33 25 30 5 11 7
14 34 26 81 74 90 133 110 52 23 748 18.5-24 19 12 2
19 09 6
4 50 9 137150 31 69458 4014 429
>24 7
10 5 35 10 9
8 2
3 6
14 1
5 27 25 3 190 TOTAL 17016117 3 5 46 47~ 12 75 19 217 254 17 6 65
Table A-2 (continued)
Jan-Dec 2005 Class A Freq:
0.106 mph N
JN NE ENE ~EsESE SE SSEI S ]SSWI SW jWSWj W JWNWI NW INNW TOTAL Calm-0.95 2
8 0
0 0
0 0
0 0
0 0
0 0
0 3
7 20 0.95-3.5 1
2 0
0 1
2 0
1 0
0 0
0 0
0 1
1 9
3.5-7.5 9
7 16 6
9 4
5 4
1 1
0 0
0 3
2 2
69 7.5-12.5 111 8
12 3
9 12 11 6
8 18 9
2 10 8
10 8
133 12.5-18.51 21 10 2
3 1
4 13 4
11 30 22 13 11 18 16 23 202 18.5-24 14 5
1 0
6 3
9 5
5 14 4
4 10 4
19 15 118
>24 29 9
0 1
6 0
0 3
0 0
0 0
2 7
4 16 77 TOA 87]49 131 I13] 32 25J38 1 23125 153J35 1191 33 J40 [55 1701 2 Class B Freq: 0.035 mph N INNEj NE IENE E ESEL SE SSEI S I SSWjI SW JWSWI W WN-wT -NNW I~TOTAL Calm-0.951 0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 3
4 0w.95-3.5 0
1 0
0 0
0 1
0 0
1 0
0 0
0 0
0 3
3.5-7.5 5
1 7
0 2
1 1
1 0
1 1
1 1
3 0
0 25 7.5-12.5 3
3 4
1 0
2 1
2 1
5 3
5 1
6 4
4 145 12.5-18.5 1
6 4
4 1
1 5
0 4
11 3
3 8
7 4
5 167 18.5-24 0
1 0
2 5
2 0
0 0
10 2
0 4
5 7
4 42
>24 3
0 0
0 8
1 0
0 0
10 0
0 3
3 2
3 2
TOTAL 12 1
1 16 7
8 3
9_
9 17 Class C Freq:
0.047 mph jN jNNEj NE JENE E1ESEJ SE SSE I S IjSSW I SW IWSWI W IWNWI NW NNWjTOTAL Calm-0.95 4
0 0
0 0
0 0
0 0
0 0
0 0
0 2
2 8
0.95-3.5 1
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 2
3.5-7.5 1
3 2
5 1
1 1
2 1
4 2
2 1
4 2
2 34 7.5-12.5 0
2 6
1 2
6 0
1 2
6 83 9
3 3
3 2
49 12.5-18.5 1 3
0 3
0 1
2 3
3 34 13 7
11 8
3 4
96 18.5-24 7
2 j0 i0 3
1 1
3 j1 10 7
0 4
7 5
3 54
>24:
5 0
0 0
2 0
1 1
3 1
3 0
6 8
4 4
38 TOTAL L9 L0 1 8 i8 I
=
L 10i 10 5
28 18 19
~ A W
=
Class D Freq: 0.367TOA Calm-0.95 5
1 0
ii1 3
1 1
1 5
2 1
2 3
8 1
36 0.95-3.5 3
5 7
5 3
2 1
0 2
4 1
2 2
1 2
0 40 3.5-7.5 1 1 13 19 8
I11 16 5
12 3
1 1 13 7
1 1
5 10 7
162 7.5-12.5 13 12 18 13 25 23 23 37 21 59 29 40 43 23 17 19 415 12.5-18.5. 20 25 37 23 20 23 37 19 30 114 89 62 103 80 44 27 753 1852 15 21 6
6 13 9
12 26 14 64 47 11 92 72 63 25 496
>24 11 17 6
22 10 8
7 4
6 23 14 1
38 56 31 13 267 TOTAL [78 94 93788 4
86 9917 7728 01 1951 1241291(i J17Sf 92 2169 66
Table A-2 (continued)
Jan-Dec 2005 Class E Freq:
0.331 mph N
SSW I SW WSW I W I WNW NW NNW TOTAL Calm-0.95 8
11 3
0 2
00 0
0 0
3 1
0 0
2 1
31 0.95-3.5 1
6 3
5 4
1 1
3 1
1 3
2 1
6 1
1 40 3.5-7.5 6
10 17 17 23 16 16 12 14 13 9
12 10 7
10 11 203 7.5-12.5 13 6
18 11 15 28 37 32 34 30 33 29 49 51 24 11 421 12.5-18.5 34 32 14 4
10 4
14 39 28 42 66 112 1165 113 38 19 734 18.5-24 13 9
5 18 3
0 3
20 7
39 91 32 69 53 24 23 409
>24 2
819 5
4 4
0 2
12 3
6 13 19 10 119 TOTAL l 77 82 l 61 74 1621 53 175 11061 861 136 12171 191 13o00 243 11181 76 11957 Class F Freq:
0.096 mph lN NNE lNE ENEl EESE SEl SSE lS SSW SW WSW WlWNW NW NNW [TOTAL Calm-0.95 0
0 0
0 0
0 1
2 1
0 0
0 0
5 0.95-3.5 1
2 2
4 1
1 1
2 1
1 1
1 1
2 0
0 21 3.5-7.5 3
2 2_
4 1
4 5
5 12 8
10 4
6 7
6 5
84 7.5-12.5 8
2 1
0 2
5 14 10 9
21 13 18 9
28 18 16 174 12.5-18.5 3
2 0
1 0
1 2
17 7
6 27 40 32 18 11 8
175 18.5-24 3
0 0
1 0_0 0
8 0
8 30 27 8
6 3
6 100
>24 0
0 0
0 000 0
0 0
5 1 1
0 0
0 7
TOTAL 18 8
5 10 4
11 23 29 I45A l 92 l77l 61 j 38j 35 566 Class G Freq:
0.018 mph N
WNW NW NNW TOTAL Calm-0.95 0
0 0
0 0
0 0
0 0
° 0
0 0
0 0
0 0
0.95-3.5 0
0 2
0 0 1 1
0 0
0 1
1 0
1 7
3.5-7.5 2
2 0
1 0
0 3
2 3
2 4
1 4
0 3
3 30 7.5-12.5 1 0 0
0 0 0 0 0 3
6 4
7 5
1 0
3 1
30 12.5-18.5 0
0 0
0 0
0 0
0 1
0 2
7 5
5 1
3 24 18.5-24 0
0 0
0 0
0 0
0 0
4 5
1 2
2 0
14
>24 0
0 0
0 0
0 00 3
0 00 0
0 3
TOTAL l2 2
12 1
0 1
4 l 1 10 6
20 18 J 121 8
9 l8 108 Class All Freq:
1.000 l mph lN lNNE lNElENEl E lESE SE SSE1 S lSSWlSWlWSWl WIWNWlNWlNNWlTOTALl Calm-0.95 19 20 3
1 3
3 2
1 1
6 7
3 2
3 16 14 104 0.95-3.5 7
16 14 14 9
7 5
6 4
7 5
5 5
10 4
4 122 3.5-7.5 37 38 63 41 47 42 36 38 34 40 39 27 33 29 33 30 607 7.5-12.5 48 33 59 29 53 76 86 91 81 133 97 108 116 119 79 59 1267 12.5-18.5 80 78 57 38 32 34 73 82 84 237 222 244 335 249 117 89 2051 18.5-24 52 38 12 27 30 l15 125 62 27 145 l185 79 1881 149 l1231 76 1233
>24 so 34 7
42 31 13 112 8I 11 35 1 37 5
56 85 60 46 532 TOTAL 7293 257 12151 192l 205 l1907239l 288 1242 60 6
432 318 l591 67
APPENDIX B PILGRIM NUCLEAR POWER STATION OFFSITE DOSE CALCULATION MANUAL No revisions were made to the PNPS Offsite Dose Calculation Manual (ODCM) during calendar year 2005.
68