Wolf Creek Nuclear Operating Corporation Wolf Creek Generating Station Docket No: 50-482 Facility Operating License No: NPF-42 Annual Radioactive Effluent Release Report Report No.29 Reporting Period: January 1, 2005 - December 31, 2005
2 of 36.
Table of Contents Page Executive Summary 4
Section I 6
Report of 2005 Radioactive Effluents: Liquid 6
2005 Liquid Effluents 8
2005 Liquid Cumulative Dose Summary - Table 1 10 2005 Liquid Cumulative Dose Summary - Table 2 11 Report of 2005 Radioactive Effluents: Airborne 12 2005 Gaseous Effluents 14 2005 Gaseous Cumulative Dose Summary - Table 1 16 2005 Gaseous Cumulative Dose Summary - Table 2 17 Section 11 18 Offsite Dose Calculation Manual Limits 18 Effluent Concentration Limits (ECLs) 18 Average Energy 19 Measurements and Approximations of Total Radioactivity (Liquid and
-19 Gaseous Effluents)
Batch Releases 21 Continuous Releases 21 Doses to a Member of the Public from Activities Inside the Site Boundary 21 Additional Information 22 2005 Effluent Concentration Limits 23 2005 Solid Waste Shipments 24 Irradiated Fuel Shipments 25 Section III 26 Meteorological Data - Hours At Each Wind Speed and Direction 26 Sectio n IV 35 Unplanned or Abnormal Releases 35 Offsite Dose Calculation Manual 35 Major changes to Liquid, Solid, or Gaseous Radioactive Waste Treatment Systems 35 Land Use Census 35 Radwaste Shipments 35 Inoperability of Effluent Monitoring Instrumentation 35 Storage Tanks 35 Attachments 36
3 of 36 Table of Contents Attachment I - WCGS Procedure AP 07B-003, Revision 5, "Offsite Dose Calculation Manual" Attachment II - WCGS Procedure AP 07B-004, Revision 10, "Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program)"
Attachment IlIl - WCGS Procedure AP 31A-100, Revision 5, "Solid Radwaste Process Control Program"
4 of 36 EXECUTIVE
SUMMARY
This Annual Radioactive Effluent Release Report (Report # 29) documents the quantities of liquid and gaseous effluents and solid waste released by Wolf Creek Generating Station (WCGS) from January 1, 2005 through December 31, 2005.
The format and content of this report are in accordance with Regulatory Guide 1.21, Revision 1, "Measuring, Evaluation, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants." Sections 1, 11, III, and IV of this report provide information required by NRC Regulatory Guide 1.21 and Section 7.2 of AP 0713-003, "Offsite Dose Calculation Manual" (ODCM).
Section I--- Section I contains, in detail, the quantities of radioactive liquid and gaseous effluents and cumulative dose summaries for 2005, tabulated for each quarter and for yearly totals.
Specific ODCM effluent limits and dose limits are also listed in Section I, along with the percentage of the effluent limits actually released and the percentages of the dose limit actually received. No effluent or dose limits were exceeded during 2005.
An elevated release pathway does not exist at WCGS. All airborne releases are considered to be ground level releases. The gaseous pathway dose determination is met by the WCGSC)DCM methodology of assigning all gaseous pathways to a hypothetical individual residing at the' highest annual X/Q and D/Q location, as specified in the ODCM. This results in a conservative
?)
estimate of dose to a member of the public, rather than determining each pathway dose for. each release condition. A conservative error of thirty percent has been estimated in the effluent~data. l K As stated above;,no ODCM dose limits were exceeded in 2005.
Section 11:--- Section II includes supplemental information on continuous and batch releases,.>-
calculated doses, and solid waste disposal. There were 72 gaseous batch releases in 2005 versus 67 in 2004. There were 62 liquid batch releases in 2005 versus 58 in 2004. \\WICGS released 0.014 curies in liquid releases during 2005 versus 0.019 curies in 2004, excluding gas and tritium.
Continuous release pathways remained the same as previous years and all continuous releases were monitored.
The report contains information on the following Performance Improvement Request (PIR):
PIR 2005-1836 - While performing a Volume Control Tank (VCT) purge to Gas Decay Tank #3 (GDT), a leak was identified on a moisture separator pressure switch (HAPS1035B). The leak resulted in an unplanned, monitored release.
Section III --- Section III documents WCGS meteorological data for wind speed, wind direction, and atmospheric stability.
Section IV --- Section IV documents unplanned and abnormal releases, changes to radwaste treatment systems, land use census, monitoring instruments, radwaste shipments, and storage tank quantities. There was one unplanned, monitored release in 2005.
No changes to events occurred on the land use census, monitoring instruments, radwaste shipments, and storage units.
5 of 36 ATTAC(HMENTS Attachment I - AP 07B-003, revision 5, "Offsite Dose Calculation Manual" Attachment II -
AP 07B-004, revision 10, "Offsite Dose Calculation Manual (Radiological Envirolmental Monitoring Program)"
Attachment IlIl -AP 31A-100, revision 5, "Solid Radwaste Process Control Program"
6 of 36 SECTION I REPORT OF 2005 RADIOA A.
Fission and Activation Products
- 1. Total Release (not including tritium, gases, alpha)
- 2. Average Diluted Concentration During Period
- 3. Percent of Applicable Limit (1)
B.
- 1. Total Release
- 2. Average Diluted Concentration During Period
- 3. Percent of Applicable Limit (2) (ECL)
C.
Dissolved and Entrained Gases
- 1. Total Release
- 2. Average Diluted Concentration During Period
- 3. Percent of Applicable Limit (3)
D.
Gross Alpha Radioactivity
- 1. Total Release E.
Volume of Waste Released (prior to dilution)
,CTIVE EFFLUENTS: LIQUID Unit Quarter 1 Ci 2.08E-03
,pCi/ml 2.65E-11 4.16E-02 Ci pCi/ml 3.20E+02 4.07E-06 4.07E-01 Quarter 2 9.92E-03 1.09'E-1 0 1.98E-01 1.26E+02 1.39'E-06 1.39iE-01 1.OC'E-02
- 1.11CE-10 5.50E-05 0.OOE+00 9.52E+07 Ci gCi/ml 2.35E-02 2.99E-1 0 1.49E-04 Ci Liters 0.OOE+00O 1.14E+08 F.
Volume of Dilution Water Used Liters 7.85E+10 9.08E+10 NOTES:
- 1) The applicable limit for the WCGS is 5 Curies per year. (Reference 10 CFR 50, Appendix I, "Guicles On Design Objectives For Light-Water Cooled Nuclear Power Reactors," Paragraph A.2.) The value is derived by dividing the total release Curies by 5 Curies and then multiplying the result by 100.
- 2) This value is derived by the following formula:
(Average Diluted Concentration) (100)
(MPC or ECL, Appendix B, Table 2 10CFR20)
- 3) This value is derived by the following formula:
(Average Diluted Concentration) (100)
% of ApplicableLimit =
I(2E3 - 04 from ODCM Section 2. 1)
7 of 36 REPORT OF 2005 RADIOA A.
Fission and Activation Products
- 1. Total Release (not including tritium, gases, alpha
- 2. Average Diluted Concentration During Period
- 3. Percent of Applicable Limit (1)
B.
- 1. Total Release
- 2. Average Diluted Concentration During Period
- 3. Percent of Applicable Limit (2) (ECL)
C.
Dissolved and Entrained Gases
- 1. Total Release
- 2. Average Diluted Concentration During Period
- 3. Percent of Applicable Limit (3)
D.
Gross Alpha Radioactivity
- 1. Total Release E.
Volume of Waste Released (prior to dilution)
F.
Volume of Dilution Water Used ACTIVE EFFLUENTS: LIQUID Unit Quarter 3 Ci 1.64E-03 liCi/ml 1.18E-11 3.27E-02 Ci gCi/ml 1.95E+01 1.41 E-07 1.41 E-02 Quarter 4 8.1 C E-04 8.23 E-12 1.62 E-02 3.62E+01 3.66 E-07 3.6E E-02 0.OOE+00 O.OOE+00 O.OOE+00 4.35 E-06 8.40E+07 Ci gCi/ml 0.OOE+00 0.OOE+00 0.OOE+O0 Ci liters 0.OOE+00 1.34E+08 liters 1.38E+11 9.84E+10 NOTES:
- 1) The applicable limit for the WCGS is 5 Curies per year. (Reference 10 CFR 50, Appendix I, "Guices On Design Objectives For Light-Water Cooled Nuclear Power Reactors," Paragraph A.2.) The value is derived by dividing the total release Curies by 5 Curies and then multiplying the result by 100.
- 2) This value is derived by the following formula:
% of Applicable Limit -
(Average Diluted Concentration) (100)
(MPC or ECL, Appendix B, Table 2, 10CFR20)
- 3) This value is derived by the following formula:
(Average Diluted Concentration) (100)
(2E -04 from ODCM Section 2. 1)
8 of 36 2005 LIQUID EFFLUENTS ntinuous Mode Quarter 2 Batch Mod(
Quarter 1 Quarter 2 Nucl des Released Unit Quarter 1 H-3 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Zn-65 Sr-89 Sr-90 Mo-99 Sb-124 Sb-125 1-131 1-133 Cs-1 34 Cs-137 Ce-141 Ce-144 Na-24 Rb-88 Nb-95 Tc-99M Sb-122 Sb-126 1-135 Gross Alpha Ar-41 Kr-85M Kr-85 Kr-87 Kr-88 Xe-1311I\\
Xe-1 331A Xe-133 Xe-1351M Xe-135 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci
- -Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 1.66E+O0 N/A
<5.68E-02
<1.14E-01
<5.68E-02 N/A
<5.68E-02
<5.68E-02
<5.68E-02
<5.68E-03
<5.68E-03
<5.68E-02 N/A N/A
<1.14E-01 N/A
<5.68E-02
<5.68E-02
<5.68E-02
<5.68E-02 N/A N/A N/A N/A N/A N/A N/A
<1.14E-02
<1.14E+00
<1.14E+00
<1.14E+00
<1.14E+00
<1.14E+00
<1.14E+00
<1.14E+00
<1.14E+00
<1.14E+00
<1.14E+00 3.71 E+01 N/A
<6.69E-02
<1.34E-01
<6.69E-02 N/A
<6.69E-02
<6.69E-02
<6.69E-02
<6.69E-03
<6.69E-03
<6.69E-02 N/A N/A
<1.34E-01 N/A
<6.69E-02
<6.69E-02
<6.69E-02
<6.69E-02 N/A N/A N/A N/A N/A N/A N/A
<1.34E-02
<1.34E+00
<1.34E+00
<1.34E+00
<1.34E+00
<1.34E+00
<1.34E+00
<1.34E+00
<1.34E+00
<1.34E+00
<1.34E+00 3.18E+02 N/A 2.28E-06
<8.81 E-04
<4.41 E-04 N/A 2.73E-05 4.68E-05
<4.41 E-04
<4.41 E-05
<4.41 E-05
<4.41 E-04
<4.41 E-04 1.OOE-03 5.24E-04 2.76E-04 2.52E-06 8.68E-05
<4.41 E-04
<4.41 E-04 N/A 2.68E-05 N/A 3.64E-05 N/A N/A 5.05E-05
<8.81 E-05 1.40E-05 3.20E-05
<8.81 E-03
<8.81 E-03 1.99E-05
<8.81 E-03 2.80E-04 2.06E-02
<8.81 E-03 2.53E-03 8.90E+01 9.98E-04
<5.30E-04
<1.06E-03
<5.30E-04 1.04E-05 2.53E-03 2.35E-04
<5.30E-04
<5.30E-05
<5.30E-05
<5.30E-04 4.21 E-04 5.46E-03 3.92E-05 1.47E-05 5.69E-06 1.25E-04
<5.30E-04
<5.30E-04 1.16E-06 N/A 3.77E-06 1.88E-05 1.04E-05 3.77E-05 N/A
<1.06E-04
<1.06E-02 1.11 E-05
<1.06E-02
<1.06E-02
<1.06E-02
<1.06E-02 1.76E-04 8.53E-03
<1.06E-02 1.28E-03 NOTE "Less than" values are calculated using the Lower Limit of Detection (LLD) values listed in Table 2-1 of the OD(CM multiplied by the volume of waste discharged during the respective quarter. The "less than" values are not included in the summation for the total release values.
9 of 36 2005 LIQUID EFFLUENTS itinuous Mode Quarter 4 Batch Mode Nucl des Released Unit Quarter 3 Quarter 3 Quarter 4 H-3 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Zn-65 Sr-89 Sr-90 Mo-99 Sb-124 Sb-125 1-131 1-135 Cs-1 34 Cs-1 37 Ce-141 Ce-144 Sr-91 Nb-95 W-187 Gross Alpha Ar-41 Kr-85M Kr-85 Kr-87 Kr-88 Xe-1 31 M\\
Xe-1 33M Xe-1 33 Xe-1 35M Xe-1 35 Ci 1.53E+00 Ci N/A Ci
<6.69E-02 Ci
<1.34E-01 Ci
<6.69E-02 Ci N/A Ci
<6.69E-02 Ci
<6.69E-02 Ci
<6.69E-02 Ci
<6.69E-03 Ci
<6.69E-03 Ci
<6.69E-02 Ci N/A Ci N/A Ci
<1.34e-01 Ci N/A Ci
<6.69E-02 Ci
<6.69E-02 Ci
<6.69E-02 Ci
<6.69E-02 Ci N/A Ci N/A Ci N/A Ci
<1.34E-02 Ci
<1.34E+00 Ci
<1.34E+00 Ci
<1.34E+00 Ci
<1.34E+00 Ci
<1.34E+00 Ci
<1.34E+00 Ci
<1.34E+00 Ci
<1.34E+00 Ci
<1.34E+00 Ci
<1.34E+00 1.30E+00 N/A
<4.19E-02
<8.37E-02
<4.19E-02 N/A
<4.19E-02
<4.19E-02
<4.19E-02
<4.19E-03
<4.19E-03
<4.19E-02 N/A N/A
<8.37E-02 N/A
<4.19E-02
<4.19E-02
<4.19E-02
<4.19E-02 N/A N/A N/A
<8.37E-03
<8.37E-01
<8.37E-01
<8.37E-01
<8.37E-01
<8.37E-01
<8.37E-01
<8.37E-01
<8.37E-01
<8.37E-01
<8.37E-01 1.79E+01 N/A 5.63E-06
<3.03E-04 1.56E-04 N/A 1.79E-04 3.38E-05 2.44E-06
<1.52E-05
<1.52E-05
<1.52E-04 1.17E-05 1.37E-03
<3.03E-04 N/A 2.20E-06 2.50E-05
<1.52E-04
<1.52E-04 3.73E-06 N/A N/A
<3.03E-05
<3.03E-03
<3.03E-03
<3.03E-03
<3.03E-03
<3.03E-03
<3.03E-03
<3.03E-03
<3.03E-03
<3.03E-03
<3.03E-03 3.49E+01 N/A
<1.46E-04
<2.92E-04
<1.46E-04 N/A 4.36E-05 2.91 E-05
<1.46E-04
<1.46E-05
<1.46E-05
<1.46E-04 N/A 4.85E-04
<2.92E-04 4.41 E-07 5.88E-06 6.40E-05
<1.46E-04
<1.46E-04 2.28E-06 1.35E-07 1.80E-04 4.35E-06
<2.92E-03
<2.92E-03
<2.92E-03
<2.92E-03
<2.92E-03
<2.92E-03
<2.92E-03
<2.92E-03
<2.92E-03
<2.92E-03 NOTE "Less than" values are calculated using the Lower Limit of Detection (LLD) values listed in Table 2-1 of the ODC(M multiplied by the volume of waste discharged during the respective quarter. The "less than" values are not included in the summation for the total release values.
10 of 36.
LIQUID CUMULATIVE DOSE
SUMMARY
(2005) TABLE 1 QUARTER 1 OF 2005 (mrem)
TOTAL DOSE TOTAL DOSE TOTAL DOSE TOTAL DOSE TOTAL DOSE TOTAL DOSE TOTAL DOSE FOR BONE FOR LIVER FOR TOTAL BODY FOR THYROID FOR KIDNEY FOR LUNG FOR GI-LLI
-ODCM CALCULATED DOSE 4.56E-04 6.04E-02 6.02E-02 6.16E-02 6.OOE-02 5.99E-02 5.98E-02 ODCM LIMIT(1) 5.OOE+00 5.00E+00 1.50E+00 5.OOE+00 5.00E+00 5.OOE+00 5.OOE+00
% OF LIMIT 9.12E-03 1.21 E+00 4.01 E+00 1.23E+00 1.20E+00 1.20E+00 1.20E+00 QUARTER 2 OF 2005 (mrem)
TOTAL DOSE FOR BONE TOTAL DOSE FOR LIVER TOTAL DOSE FOR TOTAL BODY TOTAL DOSE FOR THYROID TOTAL DOSE FOR KIDNEY TOTAL DOSE FOR LUNG TOTAL DOSE FOR GI-LLI QUARTER 3 OF 2005 (mrem)
TOTAL DOSE FOR BONE TOTAL DOSE FOR LIVER TOTAL DOSE FOR TOTAL BODY TOTAL DOSE FOR THYROID TOTAL DOSE FOR KIDNEY TOTAL DOSE FOR LUNG TOTAL DOSE FOR GI-LLI CIUARTER 4 OF 2005 (mrem)
TOTAL DOSE FOR BONE TOTAL DOSE FOR LIVER TOTAL DOSE FOR TOTAL BODY TOTAL DOSE FOR THYROID TOTAL DOSE FOR KIDNEY TOTAL DOSE FOR LUNG TOTAL DOSE FOR GI-LLI 1.32E-02 2.17E-01 2.11E-01 2.02E-01 2.05E-01 2.01 E-01 2.08E-01 8.80E-05 2.24E-02 2.23E-02 2.22E-02 2.23E-02 2.23E-02 2.23E-02 2.22E-04 5.77E-03 5.66E-03 5.45E-03 5.56E-03 5.49E-03 5.59E-03 5.OOE+00 5.OOE+00 1.50E+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 1.50E+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 1.50E+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 2.65E-01
'-.34E+00 1.41 E+01
'4.04E+00 4.1 OE+00 4.02E+00
'4.17E+00
'1.76E-03 4.47E-01 1.49E+00 4.45E-01 4.46E-01 4.45E-01 4.45E-01 4.45E-03 1.15E-01
- 3.78E-01
'1.09E-01 1.11E-01 1.1 OE-01
- 1.12E-01 TOTALS~ FOR 2OflF lmrmmx TOTAL DOSE FOR BONE 1.40E-02 1.OOE+01 I.40E-01 TOTAL DOSE FOR LIVER 3.05E-01 1.OOE+01 3.05E+01 TOTAL DOSE FOR TOTAL BODY 2.99E-01 3.OOE+00 9.97E+01 TOTAL DOSE FOR THYROID 2.91 E-01 1.OOE+01 2.91 E+0 TOTAL DOSE FOR KIDNEY 2.93E-01 1.OOE+01 2.93E+0 TOTAL DOSE FOR LUNG 2.89E-01 1.OOE+01 2.89E+0(
TOTAL DOSE FOR GI-LLI 2.96E-01 1.OOE+01 2.96E+01
- 1. Based on ODCM Section 2.2, which restricts dose to the whole body to s 1.5 mRem per quarter and 3.0 mRem per year. Dose restriction of any organ is s 5.0 mRem per quarter and 10.0 mRem per year.
00 0
0 0
D
)O
II of 36 LIQUID CUMULATIVE DOSE
SUMMARY
(2005) TABLE 2 A.
Fission and Activation Products (not including H-3, gases, alpha)
- 1.
Total Release - (Ci)
- 2.
Maximum Organ Dose (mRem)
- 3.
Organ Dose Limit (mRem)
- 4.
Percent of Limit Quarter 1 Quarter 2 Quarter 3 Quarter 4 Total
- 1.44E-02
- 1.90E-02 1.OOE+01
- 1.90E-01 2.08E-03 1.79E-03 5.OOE+OO 3.59E-02 9.92E-03 1.79E-02 5.OOE+OO 3.58E-01 1.63E-03 1.25E-04 5.OOE+OO 2.50E-03 8.1 OE-04 3.18E-04 5.OOE+OO 6.36E-03 B.
- 1.
Total Release - (Ci)
- 2.
Maximum Organ Dose (mRem)
- 3.
Organ Dose Limit (mRem)
- 4.
Percent of Limit 3.20E+02 5.98E-02 5.00E+OQ 1.20E+OO 1.26E+02 1.99E-01 5.OOE+OO 3.98E+OO 1.95E+01 2.22E-02 5.0OE+OO 4.45E-01 3.62E+01 5.45E-03 5.OOE+OO 1.09E-01 5.02E+02 2.86E-01 1.OOE+01 2.86E+OO This table is included to show the correlation between Curies released and the associated calculated maximum organ dose.
Wolf Creek ODCM methodology is used to calculate the maximum organ dose that assumes that an individual drinks the water and eats the fish from the discharge point. ODCM Section 2.2 organ dose limits are used. The less than values are not included in the summation for the total release values.
12 of 36 REPORT OF 2005 RADIOACTIVE EFFLUENTS: AIRBORNE Quarter Quarter Unit 1
2 A. Fission and Activation Gases
- 1. Total Release Ci 3.53E-01 6.02E-01
- 2. Average Release Rate for Period
,iCi/sec 4.54E-02 7.65E-02
- 1. Total Release Ci O.OOE+00 O.OOE+00
- 2. Average Release Rate for Period p.Ci/sec O.OOE+00 O.OOE+00
- 3. Percent of Applicable Limit (2)
O.OOE+00 O.OOE+00 C. Particulates
- 1. Part culates with Half-lives > 8 days Ci O.OOE+00 0.OOE+00
- 2. Average Release Rate for Period pCi/sec O.OQE+00 0.OOE+00
- 3. Percent of ODCM Limit (3)
O.OOE+00 O.OOE+00
- 4. Gross Alpha Radioactivity Ci O.OOE+00 0.OOE+00 D. Tritium
- 1. Total Release Ci 2.76E+00 1.43E+01
- 2. Average Release Rate for Period piCi/sec 3.55E-01 1.82E+00
- 3. Percent of ODCM Limit (4) 2.66E-02 1.41 E-01 NOTES:
- 1) Thce percent of ODCM limit for fission and activation gases is calculated using the following methodology:
(Qtrly Total Beta Airdose)(100)
(Qtrly Total Gamma Airdose)(100)
% of ODCM Limit =
or 10 mrad 5 mrad The largest value calculated between Gamma and Beta air dose is listed as the % of ODCM Limit.
% ofODCMLimit (Total Curies of Iodine-131)(100)
I Curie
- 3)
The percent of ODCM limit for particulates is calculated using the following methodology:
% of ODCM Limit = (Highest Organ Dose Due to Particulates)(100) 7.5 mrem This type of methodology is used since the Wolf Creek ties release limits to doses rather than curie release rates.
- 4)
The percent of ODCM limit for tritium is calculated using the following methodology:
% of ODCM Limit =(Highest Organ Dose Due to H-3)(100) 7.5 mrem
13 of 36 REPORT OF 2005 RADIOACTIVE EFFLUENTS: AIRBORNE Quarter Quarter Unit 3
4 A. Fis:3ion and Activation Gases
- 1. Total Release Ci 1.78E-01 3.98E-01
- 2. Ave rage Release Rate for Period pCi/sec 2.23E-02 5.OOE-02
- 3. Percent of ODCM Limit (1) 2.16E-03 3.31E-03 B. lodines
- 1. Total Iodine-131 Ci 0.OOE+00 O.OOE+00
- 2. Average Release Rate for Period pCi/sec O.OOE+00 O.OOE+00
- 3. Percent of Applicable Limit (2) 0.OOE+00 O.OOE+00 C. Parliculates
- 1. Particulates with Half-lives > 8 days Ci O.OOE+00 O.OOE+00
- 2. Average Release Rate for Period pCi/sec 0.OOE+00 O.OOE+00
- 3. Percent of ODCM Limit (3)
O.OOE+00 O.OOE+00
- 4. Gross Alpha Radioactivity Ci O.OOE+00 O.OOE+00 D. Tritium
- 1. Tolal Release Ci 1.39E+01 1.30E+01
- 2. Average Release Rate for Period pCi/sec 1.75E+00 1.64E+00
- 3. Percent of ODCM Limit (4) 1.37E-01 1.10E-01 NOTES:
- 1) The percent of ODCM limit for fission and activation gases is calculated using the following methodology:
% of ODCM Limit= (QtrlyTotal Beta Airdose)(100)
(QtrlyTotal Gamma Airdose)'100) 10 mrad 5 mrad The largest value calculated between Gamma and Beta air dose is listed as the % of ODCM Limit.
% of ODCM Limit = (Total Curies of Iodine-131)(100)
I Curie
- 3) The percent of ODCM limit for particulates is calculated using the following methodology:
% of ODCMLimit (Highest Organ Dose Due to Particulates)(100) 7.5 mrem This type of methodology is used since the Wolf Creek ODCM ties release limits to doses rather than curie release rates.
- 4)
The percent of ODCM limit for tritium is calculated using the following methodology:
% of ODCM Limit =(Highest Organ Dose Due to H-3)(100) 7.5 mrem
14 of 36 2005 GASEOUS EFFLUENTS Continuous Mode Batch Mode Quarter 1 Quaiter 2 Nuclides Released
- 1.
Fission and Activiation Gases Ar-41 Kr-85 Kr-85M Kr-87 Kr-88 Xe-131M Xe-133 Xe-1 33M Xe-1 35 Xe-135M Xe-1 38 Total
- 2.
Halogens (Gaseous) 1-131 1-133 Total
- 3.
Pailiculates and Tritium H-3 Mn-54 Fe-59 Co,-58 Co-60 Zn-65 Mo-99 Cs-1 34 Cs-1 37 Ce-141 Ce-144 Sr-89 Sr-90 Gross Alpha Total Unit Quarter 1 Quarter 2 Ci N/A Ci N/A Ci N/A Ci
<1.35E+01 Ci
<1.09E+01 Ci N/A Ci
<4.34E+00 Ci
<1.44E+01 Ci
<1.54E+00 Ci N/A Ci
<1.63E+03 Ci 0.00E+00 Ci
<2.58E-04 Ci
<2.58E-02 Ci 0.00E+00 N/A N/A N/A
<1.41 E+01
<1.13E+01 N/A
<4.51 E+00
<1.49E+01
<1.60E+00 N/A
<1.69E+03 0.00E+00
<2.68E-04
<2.68E-02 0.OOE+00 9.66E+00
<2.68E-03
<2.68E-03
<2.68E-03
<2.68E-03
<2.68E-03
<2.68E-03
<2.68E-03
<2.68E-03
<2.68E-03
<2.68E-03
<2.68E-03
<2.68E-03
<2.68E-03 9.66E+00 3.21 E-01 2.86E-02 N/A
<1.88E-02
<1.51 E-02 5.98E-05 3.73E-03 2.36E-05
<3.66E-03 N/A
<2.25E+00 3.53E-01
<3.58E-07
<3.58E-05 0.00E+00 1.68E-01
<3.58E-06
<3.58E-06
<3.58E-06
<3.58E-06
<3.58E-06
<3.58E-06
<3.58E-06
<3.58E-06
<3.58E-06
<3.58E-06
<3.58E-06
<3.58E-06
<3.58E-06 1.68E-01 2.74E-01 4.07E-02 5.05E-05 1.12E-04 1.43E-04 1.26E-03 2.75E-01 3.91 E-03 1.1 3E-03 1.62E-04 3.13E-04 6.01 E-01
<1.70E-05
<1.70E-03 0.OC E+00 4.651-+00
<1.70E-04
<1.70E-04
<1.70E-04
<1.70E-04
<1.70E-04
<1.7C1E-04
<1.7CIE-04
<1.7CIE-04
<1.7(1E-04
<1.7(1E-04
<1.7(1E-04
<1.70E-04
<1.7(1E-04 4.6E E+00 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 2.59E+00
<2.58E-03
<2.58E-03
<2.58E-03
<2.58E-03
<2.58E-03
<2.58E-03
<2.58E-03
<2.58E-03
<2.58E-03
<2.58E-03
<2.58E-03
<2.58E-03
<2.58E-03 2.59E+00 NOTE "Less than" values for Noble Gases are calculated using the Lower Limit of Detection (LLD) values; obtained at Wolf Creek Generating Station multiplied by the volume of air discharged during the respective quarter.
For the Halogens and Particulates the ODCM LLD values are used.
15 of 36 2005 GASEOUS EFFLUENTS Continuous Mode Batch Mode Quarter 3 Quaiter 4 Nuclides Released
- 1. Fission and Activiation Gases Ar-41 Kr-85 Kr-85M Kr-87 Kr-88 Xe-131M Xe-1 33 Xe-1 33M Xe-1 35 Xe-138 Total
- 2.
Halogens (Gaseous) 1-131 1-133 Total
- 3.
Pailiculates and Tritium H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Mo-99 Cs-1 34 Cs-1 37 Ce-141 Ce-144 Sr-89 Sr-90 Gross Alpha Total Unit Quarter 3 Quarter 4 Ci N/A Ci N/A Ci N/A Ci
<1.40E+01 Ci
<1.13E+01 Ci N/A Ci
<4.50E+00 Ci
<1.49E+01 Ci
<1.59E+00 Ci
<1.68E+03 Ci 0.OOE+00 Ci
<2.67E-04 Ci
<2.67E-02 Ci O.OOE+00 Ci 1.34E+01 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci
<2.67E-03 Ci 1.34E+01 N/A N/A N/A
<1.39E+01
<1.12E+01 N/A
<4.45E+00
<1.47E+01 1.80E-01
<1.67E+03 1.80E-01
<2.64E-04
<2.64E-02 0.OOE+00 1.27E+01
<2.64E-03
<2.64E-03
<2.64E-03
<2.64E-03
<2.64E-03
<2.64E-03
<2.64E-03
<2.64E-03
<2.64E-03
<2.64E-03
<2.64E-03
<2.64E-03
<2.64E-03 1.27E+01 1.66E-01 5.90E-03 N/A
<1.01 E-02
<8.16E-03 N/A 5.26E-03 6.64E-05 2.61 E-05
<1.22E+00 1.78E-01
<1.93E-07
<1.93E-05 O.00E+00 5.27E-01
<1.93E-06
<1.93E-06
<1.93E-06
<1.93E-06
<1.93E-06
<1.93E-06
<1.93E-06
<1.93E-06
<1.93E-06
<1.93E-06
<1.93E-06
<1.93E-06
<1.93E-06 5.27E-01 2.18E-01 N'A N'A
<1.16E-02
<9.37E-03 N/A
<3.72E-03
<1.2:3E-02
<1.32E-03
<1.4C0E+00 2.18E-01
<2.2-1 E-07
<2.2-1 E-05 0.00E+00 3.71 E-01
<2.2'i E-06
<2.2, E-06
<2.2' E-06
<2.2 E-06
<2.2, E-06
<2.21 E-06
<2.21 E-06
<2.21 E-06
<2.21 E-06
<2.21 E-06
<2.21 E-06
<2.21 E-06
<2.21 E-06 3.71,E-01 NOTE "Less than" values for Noble Gases are calculated using the Lower Limit of Detection (LLD) values obtained at Wolf Creek Generating Station multiplied by the volume of air discharged during the respective quarter.
For the Halogens and Particulates, the ODCM LLD values are used.
16 of 36.
GASEOUS CUMULATIVE DOSE
SUMMARY
(2005) TABLE 1 QUARTER 1 OF 2005 (mRem)
TOTAL DOSE TOTAL DOSE TOTAL DOSE TOTAL DOSE TOTAL DOSE TOTAL DOSE TOTAL DOSE FOR BONE FOR LIVER FOR TOTAL BODY FOR THYROID FOR KIDNEY FOR LUNG FOR GI-LLI
- ODOM CALCULATED DOSE 0.OOE+00 1.95E-03 1.95E-03 1.95E-03 1.95E-03 1.95E-03 1.95E-03 ODCM LIMIT (1) 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00
% OF LIMIT 0.30E+00 2.60E-02 2.60E-02 2.60E-02 2.60E-02 2.60E-02 2.60E-02 QUARTER 2 OF 2005 (mRem)
TOTAL DOSE FOR BONE TOTAL DOSE FOR LIVER TOTAL DOSE FOR TOTAL BODY TOTAL DOSE FOR THYROID TOTAL DOSE FOR KIDNEY TOTAL DOSE FOR LUNG TOTAL DOSE FOR GI-LLI QUARTER 3 OF 2005 (mRem)
TOTAL DOSE FOR BONE TOTAL DOSE FOR LIVER TOTAL DOSE FOR TOTAL BODY TOTAL DOSE FOR THYROID TOTAL DOSE FOR KIDNEY TOTAL DOSE FOR LUNG TOTAL DOSE FOR GI-LLI 0.OOE+00 1.01 E-02 1.01 E-02 1.01 E-02 1.01 E-02 1.01 E-02 1.01 E-02 0.OOE+00 9.86E-03 9.86E-03 9.86E-03 9.86E-03 9.86E-03 9.86E-03 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 0.D0E+00 1.35E-01 1.35E-01 1.35E-01 1.35E-01 1.35E-01 1.35E-01 0.00E+00 1.31 E-01 1.31 E-01 1.31 E-01 1.31 E-01 1.31 E-01 1.31 E-01 QUARTER 4 OF 2005 (mRem)
TOTAL DOSE FOR BONE TOTAL DOSE FOR LIVER TOTAL DOSE FOR TOTAL BODY TOTAL DOSE FOR THYROID TOTAL DOSE FOR KIDNEY TOTAL DOSE FOR LUNG TOTAL DOSE FOR GI-LLI TOTALS FOR 2005 (mRem)
TOTAL DOSE FOR BONE TOTAL DOSE FOR LIVER TOTAL DOSE FOR TOTAL BODY TOTAL DOSE FOR THYROID TOTAL DOSE FOR KIDNEY TOTAL DOSE FOR LUNG TOTAL DOSE FOR GI-LLI 0.00E+00 9.22E-03 9.22E-03 9.22E-03 9.22E-03 9.22E-03 9.22E-03 0.00E+00 3.11E-02 3.11E-02 3.11 E-02 3.11 E-02 3.11E-02 3.11E-02 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 0.00E+00 1.23E-01 1.23E-01 1.23E-01 1.23E-01 1.23E-01 1.23E-01 0.00E+00 2.08E-01 2.08E-01 2.08E-01 2.08E-01 2.08E-01 2.08E-01
- 1. Based on Wolf Creek ODOM Section 3.2.2 which restricts dose during any calendar quarter to less than or equal to 7.5 mRem to any organ and during any calendar year to less than or equal to 15 mRem to any organ.
17 of 36 GASEOUS CUMULATIVE DOSE
SUMMARY
(2005) TABLE 2 Nuclides Released Quarter 1 Quarter 2 Quarter 3 Quarter 4 Total A.
Fission and Activation Gases
- 1.
Total Release - (Ci) 3.53E-01 6.02E-01 1.78E-01 3.98E-01 1.53E+00
- 2.
Total Gamma Airdose (mRad) 2.08E-04 1.88E-04 1.08E-04 1.65E-04 6.70E-04
- 3.
Gamma Airdose Limit (mRad) 5.OOE+00 5.00E+00 5.OOE+00 5.OOE+00 1.00E+01
- 4.
Percent of Gamma Airdose Limit 4.16E-03 3.76E-03 2.16E-03 3.31 E-03 6.70E-03
- 5.
Total Beta Airdose (mRad) 7.75E-05 9.03E-05 3.92E-05 8.07E-05 2.88E-04
- 6.
Beta Airdose Limit (mRad) 1.OOE+01 1.OOE+01 1.00E+01 1.OOE+01 2.OOE+01
- 7.
Percent of Beta Airdose 7.75E-04 9.03E-04 3.92E-04 8.07E-04 1.44E-03 Limit (mRad)
B.
Particulates
- 1.
Total Particulates (Ci) 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 2.
Maximum Organ Dose (mRem) 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00
- 3.
Organ Dose Limit (mRem) 0.OOE+00 7.50E+00 7.50E+00 7.50E+00 1.50E+01
- 4.
Percent of Limit 0.OOE+00 O.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 C.
- 1.
Total Release (Ci) 2.76E+00 1.43E+01 1.39E+01 1.30E+01 4.41 E+01
- 2.
Maximum Organ Dose (mRem) 2.OOE-03 1.06E-02 1.03E-02 8.25E-03 3.11E-02
- 3.
Organ Dose Limit (mRem) 7.50E+00 7.50E+00 7.50E+00 7.50E+00 1.50E+01
- 4.
Percent of Limit 2.66E-02 1.41E-01 1.37E-01 1.10E-01 2.08E-01 D.
- 1.
Total 1-131,1-133 (Ci)
O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00
- 2.
Maximum Organ Dose (mRem)
O.OOE+00 0.OOE+00 0.O0E+00 0.OOE+00 0.OOE+00
- 3.
Organ Dose Limit (mRem) 7.50E+00 7.50E+00 7.50E+00 7.50E+00 1.50E+01
- 4.
Percent of Limit 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 This table is included to show the correlation between Curies released and the associated calculated maximum organ dose. The maximum organ dose is calculated using Wolf Creek ODCM methodology which assumes that an individual actually resides at the release point. ODCM Section 3.2.2 organ dose limits are used.
18 of 36 SECTION II SUPPLEMENTAL INFORMATION
- 1. Offsite Dose Calculation Manual Limits A. For liquid waste effluents A.1 The concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS shall be limited to the concentrations specified in 10 CFR 20, Appendix B, Table II, Column 2, for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2 x 10 microCuries/mi total activity.
A.2 The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released, from each unit, to UNRESTRICTED AREAS shall be limited:
- a. During any calendar quarter to less than or equal to 1.5 mrems to the whole body and to less than or equal to 5 mrems to any organ, and
- b. During any calendar year to less than or equal to 3 mrems, to the whole body and to less than or equal to 10 mrems to any organ.
B. For gaseous waste effluents B.1 The dose rate due to radioactive material released in gaseous effluents from the site to area at and beyond the SITE BOUNDARY shall be limited to the following:
- a. For noble gases: Less than or equal to 500 mrems/yr to the whole body and less than or equal to 3000 mrems/yr to the skin, and
- b. For lodine-131, Iodine-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days: Less than or equal to 1500 mrems/yr to any organ.
B.2 The air dose due to noble gases released in gaseous effluents, from each unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following:
- a. During any calendar quarter: Less than or equal to 5 mrads for gamma radiation and less than or equal to 10 mrads for beta radiation, and
- b. During any calendar year: Less than or equal to 10 mrads for gamma radiation and less than or equal to 20 mrads for beta radiation.
B.3 The dose from lodine-131, Iodine-133, tritium, and a radionuclide in particulate form with half-lives greater than 8 days in gaseous effluents released to area at and beyond the SITE BOUNDARY shall be limited to the following:
- a.
During any calendar quarter: Less than or equal to 7.5 mrems to any organ, and
- b. During any calendar year: Less than or equal to 15 mrems to any organ.
- 2.
Effluent Concentration Limits (ECLs)
Water - covered in Section l.A.
Air - covered in Section l.B.
19 of 36
- 3.
Average Energy Average energy of fission and activation gaseous effluents is not applicable. See ODCM Section 3.1 for the methodology used in determining the release rate limits from noble gas releases.
- 4.
Measurements and Approximations of Total Radioactivity A.
Liquid Effluents Liquid Release Sampling Method of Analysis Type of Activity Type Frequency Analysis P
- 1. Batch Waste Each Batch P.H.A.
Principal Gamma Emitters Release Tank P
Each Batch P.H.A.
1-131
- a. Waste Monitor P
P.H.A.
Dissolved and Entrained Tank One BatchlM Gases (Gamma Emitters)
- b. Secondary Liquid P
L.S.
H-3 Waste Monitor Each Batch S.A.C.
Gross Alpha ranks P
O.S.L.
Sr-89. Sr-90
- 2. Continuous Daily P.H.A.
Principal Gamma Emilters Releases Grab Sample P.H.A.
1-131
- a. Steam Generator M
Dissolved and entrained Blowdown Grab Sample P.H.A.
Gases (Gamma Emitters)
- b. Turbine Building Daily L.S.
H-3 Sump/Waste Water Grab Sample Treatment S.A.C.
Gross Alpha O.S.L.
Sr-89, Sr-90
- c. Lim D Sludge Pond Daily Grab Sample O.S.L.
Fe-55 P = pric r to each batch M = monthly L. S. = Liquid scintillation detector S.A.C. = scintillation alpha counter O.S.L. = performed by an off site laboratory P.H.A. = gamma spectrum pulse height analysis using a High Purity Germanium detector
20 of 36 B.
Gaseous Waste Effluents Gaseous, Release Sampling Frequency Method of Analysis Type of Activity Type Analysis P
P.H.A.
Principal Gamma Emitters Waste Gas Decay Tank Each Tank Grab Sample Containment Purge or P
P.H.A.
Principal Gamma Emit!:ers Vent Each Purge Grab Sample Gas Bubbler and L.S.
H-3 (oxide)
Unit Vent M
P.H.A.
Principal Gamma Emitters Grab Sample Gas Bubbler and L.S.
H-3 (oxide)
Radwaste Building M
P.H.A Principal Gamma Emitters Vent Grab Sample For Unit Vent and Continuous P.H.A.
1-131 Radwaste Building Vent release types 1-133 listed above Continuous P.H.A.
Principal Gamma Emitters Particulate Sample Continuous S.A.C.
Gross Alpha Composite Particulate Sample Continuous O.S.L.
Sr-89, Sr-90 Composite Particulate Sample P = prior to each batch M = monthly L.S. = Liquid scintillation detector S.A.C. = scintillation alpha counter O.S.L. = performed by an offsite laboratory P.H.A. = gamma spectrum pulse height analysis using a High Purity Germanium detector
21 of 36
- 5. Balch Releases A batch release is the discontinuous release of gaseous or liquid effluents which takes place over a finite period of time; usually hours or days.
There were 72 gaseous batch releases during the reporting period. The longest gaseous batch release lasted 9777 minutes, while the shortest lasted 75 minutes. The average release lasted 538 minutes with a total gaseous batch release time of 45,683 minutes.
There were 62 liquid batch releases during the reporting period. The longest liquid batch release lasted 375 minutes, while the shortest lasted 30 minutes. The average release lasted 156 minutes with a total liquid batch release time of 10,545 minutes.
- 6. Continuous Releases A continuous release is a release of gaseous or liquid effluent, which is essentially uninterrupted for extended periods during normal operation of the facility. Four liquid release pathways were designated as continuous releases during this reporting period:
Steam Generator Blowdown, Turbine Building Sump, Waste Water Treatment, and Lime Sludge Pond. Two gas release pathways were designated as continuous releases: Unit Vent and Radwaste Building Vent.
- 7. Doses to a Member of the Public from Activities Inside the Site Boundary Four activities by members of the public were considered in this evaluation: personnel making deliveries to the plant, workers at the William Allen White Building located outside of the protected area boundary, the use of the access road south of the Radwaste Building, and public use of the cooling lake during times when fishing was allowed. The dose calculated for the maximum exposed individual for these four activities vwas as follows:
Plant Deliveries 3.36E-01 mRem William Allen White Building Workers 7.42E-03 mRem Access Road Users 3.54E-03 mRem Lake Use 4.57E-02 mRem The plant delivery calculations were based on deliveries 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> per week for 50 Weeks per year. The William Allen White Building occupancy was based on normal working hours of 2000 per year. The usage factor for the access road south of the Rac'waste Building was 25 hours2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br /> per year. The dose to fishermen on the lake was based upon 4356 hours0.0504 days <br />1.21 hours <br />0.0072 weeks <br />0.00166 months <br /> (12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> a day for 363 days, based on the number of days that the lake was open to fisherman).
Pathways used in the calculation were gaseous inhalation, submersion, and ground plane. All calculations were performed in accordance with the methodology and parameters in the ODCM.
22 of 36
- 8. Additional Information PIR 2005-1836 - While performing a Volume Control Tank (VCT) purge to Gas Decay Tank #3 (GDT), a leak was identified on a Swagelok fitting on a moisture separator pressure switch (HAPS1035B). During the VCT purge, the Radwaste Treatment Systems Operator noticed a significant drop in pressure. The purge was secured and the system lineup verified, with no deficiencies found. The leak was found to be at a fitting on HAPS1035B, which allowed an unexpected pressure loss from GDT #3, from 21 psig to 6.8 psig over a time period of 94 minutes. Work Request 05-050478 was written. The leak resulted in an unplanned, monitored release of noble gases from the Radwaste Building Vent. No ODCM limits were exceeded. An estimated 6.22E-03 curies were released.
23 of 36 2005 EFFLUENT CONCENTRATION LIMITS Nuclides Curies Averaqe Diluted Concentration (uCi/ml) 10 CFR 20 ECL (uCi/ml)
% of ECL H-3 Cr-51 Mn-54 Mn-56 Co-57 Co-58 Co-60 Sb-1 25 Sb-1 2L 1-131 1-133 1-135 Ce-141 Cs-1 3-Cs-1 37 Nb-97 Ba-1 39 Rb-88 Sn-i 1 7M Sb-1 22 Sb-126 Na-24 Nb-95 Tc-99hi Fe-59 Sr-91 Zn-65 W-187 Ar-41 Kr-85 Kr-85NI Kr-88 Xe-131 M Xe-1 3,M Xe-1 3, Xe-1 3E, 5.01 E+02 9.98E-04 7.91 E-06 N/A 1.04E-05 2.79E-03 3.44E-04 8.32E-03 4.33E-04 5.63E-04 2.91 E-04 5.09E-05 N/A 1.63E-05 3.01 E-04 N/A N/A 2.68E-05 N/A 1.04E-05 3.78E-05 1.16E-06 3.91 E-06 5.53E-05 1.56E-06 6.01 E-06 2.44E-06 1.80E-04 1.40E-05 N/A 4.30E-05 1.99E-05 N/A 4.55E-04 2.91 E-02 3.81 E-03 1.23E-06 2.46E-12 1.95E-14 N/A 2.56E-14 6.87E-12 8.47E-1 3 2.05E-1 1 1.07E-12 1.39E-12 7.17E-13 1.25E-13 N/A 4.01 E-14 7.41 E-13 N/A N/A 6.60E-1 4 N/A 2.56E-1 4 9.31 E-1 4 2.86E-1 5 9.63E-1 5 1.36E-1 3 3.84E-15 1.48E-14 6.01 E-1 5 4.43E-1 3 3.45E-1 4 N/A 1.06E-13 4.90E-14 N/A 1.12E-12 7.17E-1 1 9.38E-1 2 1.OOE-03 5.00E-04 3.OOE-05 7.OOE-05 6.OOE-05 2.OOE-05 3.OOE-06 3.OOE-05 7.OOE-06 1.OOE-06 7.00E-06 3.OOE-05 3.OOE-05 9.OOE-07 1.OOE-06 3.OOE-04 2.OOE-04 4.OOE-04 1.OOE-08 1.OOE-05 7.OOE-06 5.OOE-05 3.OOE-05 1.OOE-03 1.OOE-05 2.OOE-05 5.OOE-06 3.OOE-05 2.OOE-04 2.OOE-04 2.OOE-04 2.OOE-04 2.OOE-04 2.OOE-04 2.OOE-04 2.OOE-04 1.23E-01 4.92E-07 6.50E-08 N/A 4.27E-08 3.44E-05 2.82E-05 6.83E-05 1.53E-05 1.39E-04 1.02E-05 4.17E-07 N/A 4.46E-06 7.41 E-05 N/A N/A 1.65E-08 N/A 2.56E-07 1.33E-06 5.72E-09 3.21 E-08 1.36E-08 3.84E-08 7.40E-08 1.20E-07 1.48E-06 1.73E-08 N/A 5.30E-08 2.45E-08 N/A 5.60E-07 3.59E-05 4.69E-06
24 of 36 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2005 SOLID WASTE SHIPMENTS A. SOL.ID RADWASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)
- 1. Type of Waste Unit 1-Year Period Est. Total Error %
- a. Spent resins, filter sludges evaporator bottoms, etc.
- b. Dry compressible waste, contaminated equip. etc.
- c. Irradiated components, control rods, etc.
m3*
Ci m3*
Ci m3*
Ci 1.07E+01**
6.48E+02 3.47E+02**
1.56E+00 O.OOE+00 O.OOE+00 2.50E+01 2.50E+01 2.50E+01
- d. Other m3*
O.OOE+00 Ci O.OOE+00 2.50E+01
- m3 = cubic meters
- This is the volume sent offsite for volume reduction, prior.to disposal.
- 2. Estimate of Major Nuclide Composition (by type of waste).
[Nuclides listed with % abundance greater than 10 %]
- a. Spent resin, filter sludges, evaporator bottoms, etc.
Nuclide Name Percent Abundance 24 52 11 Fe-55 Ni-63 Co-60 Curies 1.57E+02 3.34E+02 7.03e+01
- b. Dry compressible waste, contaminated equipment, etc.
Nuclide Name Percent Abundance 61 23 Curies 9.41 E-01 3.57E-01 Fe-55 Ni-63
25 of 36
- c. Irradiated components, control rods, etc. - None
- d. Other - None
- 3. Solid Waste Disposition Number of Shipments Mode of Transportation Destination 2
3 2
1 2
Truck (Hittman Transport Services)
Truck (Hittman Transport Services)
Truck (Hittman Transport Services)
Truck (RACE Logistics, LLC)
Truck (RSB Logistics)
Barnwell Waste Management Facility, Barnwell, SC Duratek; Kingston, TN Studsvik Processing Facility, LLC; Erwin, TN RACE, LLC; Memphis, TN Studsvik Processing Facility, LLC; Erwin, TN
- 4. Class of Solid Waste
- a. Class A, Class B, Class C-Corresponding to 2a
- b. Class A -
Corresponding to 2b
- c. Not applicable
- d. Not applicable
- 5. Type of Container
- a. LSA (Strong, tight), Type A, Type B - corresponding to 2a
- b. LSA (Strong, tight) - corresponding to 2b
- c. Not applicable
- d. Not applicable
- 6. Solidification Agent
- a. Not applicable
- b. Not applicable
- c. Not applicable
- d. Not applicable B. IRRADIATED FUEL SHIPMENTS (Disposition)
No irradiated fuel shipments occurred during the 2005 period.
26 of 36 SECTION III HOURS AT EACH WIND SPEED AND DIRECTION This section documents WCGS meteorological data for wind speed, wind direction, and atmospheric stability.
The meteorological data supplied in the following tables covers the period from January 1, 2005, through December 31, 2005, and indicates the number of hours at each wind speed and direction for each stability class. All gaseous releases at the WCGS are ground level releases.
Wolf C:reek Station did meet Regulatory Guide 1.23 requirement for data recovery and had a 90.580/% meteorological data recovery for 2005.
27 of 36 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:
JANUARY 1 THROUGH DECEMBER 31, 2005 STABILITY CLASS:
A ELEVATION:
10 METERS WIND DIRECTION N
NNE NE ENE E
- WSW, W
WNW NW NNW TOT AL WIND SPEED (mph) 8-12 13-18 19-24 1-3 0.00 7.50 0.50 0.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50 0.00 0.50 0.25 0.25 9.75 4-7 0.25 1.25 2.50 0.50 3.25 1.75 1.25 1.75 2.25 0.50 0.75 1.50 3.75 2.00 4.50 1.50 29.25 3.50 3.00 5.75 1.75 3.00 8.00 7.75 27.50 40.75 14.25 6.00 5.00 14.00 7.50 5.50 9.25 162.50 11.00 11.25 3.50 1.00 4.25 6.50 4.25 18.75 83.75 46.75 1.50 1.75 5.50 10.50 8.00 10.75 229.00 3.25 0.50 0.00 0.00 0.00 0.00 0.00 4.50 18.25 11.75 0.00 0.00 1.25 3.25 3.25 8.75 54.75
>24 1.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50 0.50 0.00 0.25 1.00 0.50 0.75 3.75 8.75 TOTAL 19.50 23.50 12.25 3.50 10.50 16.25 13.25 52.50 145.50 73.75 8.25 9.00 25.50 24.25 22.25 34.25 494.00 PERIOD OF CALM (HOURS): 0
28 of 36 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:
JANUARY 1 THROUGH DECEMBER 31,2005 STABILITY CLASS:
B ELEVATION:
10 METERS WIND SPEED (mph)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
1.00 2.75 10.25 10.25 3.75 0.50 28.50 NNE 0.25 2.50 6.75 8.75 0.75 0.00 19.00 NE 0.50 3.00 5.25 1.75 0.25 0.00 10.75 ENE 0.00 3.75 2.50 0.50 0.00 0.00 6.75 E
0.00 21.50 4.75 0.75 0.50 0.50 28.00 ESE 0.00 1.25 3.50 2.50 0.00 0.00 7.25 SE 0.00 2.00 10.25 1.75 0.25 0.00 1425 SSE 0.25 5.25 12.25 5.50 2.00 0.00 25.25 S
0.00 5.50 24.75 20.50 8.75 0.25 59.75 SSW 0.25 3.00 18.25 23.75 4.00 0.50 49.75 SW 0.00 1.75 8.25 0.25 0.25 0.00 10.50.
WSW 1.25 3.50 3.75 0.25 0.00 0.75 9.50 W
0.50 3.75 8.75 3.25 0.25 1.75 18.25 WNW b.50 3.75 7.50 2.00 0.75 1.25 15.75 NW 0.50 5.00 7.25 9.25 2.25 0.50 24.75 NNW 0.50 3.00 6.50 8.75 6.25 1.25 26.25 TO1AL 4.50 71.25 140.50 99.75 30.00 7.25 354.25 PERIOD OF CALM (HOURS): 0
29 of 36 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:
JANUARY 1 THROUGH DECEMBER 31, 2005 STABILITY CLASS:
C ELEVATION:
10 METERS WIND SPEED (mph)
WIND DIRECTION N
NNE NE ENE E
W WNW NW NNW TOTAL 1-3 1.25 0.75 1.50 1.00 1.25 0.00 0.75 0.50 0.25 2.00 0.50 1.00 0.75 0.25 1.00 0.25 11.75 4-7 9.50 10.50 8.25 9.75 11.25 6.25 5.75 11.75 14.75 5.00 5.00 5.00 5.50 4.75 7.00 3.75 123.75 8-12 13-18 19-24
>24 14.25 10.75 6.75 7.25 7.00 6.00 10.75 24.25 23.75 23.00 8.00 6.00 10.25 6.25 5.00 11.00 180.25 17.50 5.50 2.25 2.25 1.25
.1.75 2.75 7.75 15.25 19.75 1.50 1.25 4.25 2.50 9.75 10.75 106.00 3.00 1.00 0.00 0.00 1.00 0.00 0.00 1.50 9.00 3.00 0.25 0.00 0.25 0.50 5.50 3.25 28.25 0.25 0.00 0.00 0.00 0.75 0.00 0.00 0.00 0.25 0.00 0.00 1.00 0.00 1.00 2.00 2.00 7.25 TOTAL 45.75 28.50 18.75 20.25 22.50 14.00 20.00 45.75 63.25 52.75 15.25 14.25 21.00 15.25 30.25 31.00 458.50 PERIOD OF CALM (HOURS): 0.25
30 of 36 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:
JANUARY 1 THROUGH DECEMBER 31, 2005 STABILITY CLASS:
D ELEVATION:
10 METERS WIND SPEED (mph)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
11.50 62.00 142.25 97.25 13.25 1.50 327.75 NNE 7.75 52.00 121.50 579.75 3.75 2.50 767.25 NE 27.00 119.50 75.75 18.00 0.25 0.25 240.75 ENE 16.00 69.75 30.75 3.00 0.25 0.00 119.75 E
12.00 60.75 61.00 8.25 5.50 0.25 147.75 ESE 13.25 44.00 49.50 7.75 2.50 0.00 117.00 SE 12.25 37.75 52.25 11.75 1.50 0.00 115.50 SSE 27.25 62.75 77.00 33.00 10.75 0.75 211.50 S
9.50 54.25 133.00 137.75 44.50 3.50 382.50 SSW 9.00 48.75 84.25 52.25 10.25 1.75 206.25.
SW 7.00 46.00 17.50 3.00 0.50 0.75 74.75 WSW 12.25 29.50 17.50 3.75 1.50 1.75 66.25 W
7.25 24.25 28.75 10.50 2.25 0.50 73.50 WNW 16.25 29.50 41.75 21.25 9.75 1.25 119.75 NW 15.75 17.25 40.00 60.50 16.25 3.00 152.75 NNW 16.75 37.50 72.50 51.75 12.25 5.25 196.00 TOTAL 209.25 795.50 1045.25 1099.50 135.00 23.00 3319.00 PERIOD OF CALM (HOURS): 4
31 of 36 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:
JANUARY 1 THROUGH DECEMBER 31, 2005 STABILITY CLASS:
E ELEVATION:
10 METERS WIND SPEED (mph)
WIND DIRECTION 1-3 4-7 8-12 13-18 19-24
>24 TOTAL N
6.75 35.00 48.25 9.00 0.75 0.25 100.00 NNE 17.00 19.75 22.50 4.00 0.50 0.50 64.25 NE 21.25 33.75 17.50 0.75 0.00 0.00 73.25 ENE 17.50 32.00 11.25 1.00 0.00 0.00 61.75 E
.20.75 51.25 34.25 10.00 1.25 0.00 117.50 ESE 12.50 55.25 34.75 6.75 0.00 0.00 109.25 SE 11.00 56.25 44.00 10.00 0.50 0.00 121.75 SSE 7.25 91.75 180.25 77.25 10.00 0.00 366.50 S
5.50 67.75 188.00 154.25 39.75 1.25 456.50 SSW 8.00 36.50 92.75 35.50 7.00 0.75 180.50 SW 8.25 50.75 13.75 3.50 0.00 0.00 76.25 WSW 3.25 18.50 19.75 4.00 0.00 0.25 45.75 W
3.75 15.25 38.75 4.25 0.25 0.00 62.25 WNW 1.75 13.00 33.00 3.25 1.00 0.00 52.00 NW 3.25 24.25 26.50 9.75 1.50 0.50 65.75 NNW 5.75 36.25 31.00 7.25 2.00 1.50 83.75 TOTAL 146.75 637.25 836.25 340.50 64.50 5.00 2037.00 PERIOD OF CALM (HOURS): 188.25
32 of 36.
HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:
JANUARY 1 THROUGH DECEMBER 31, 2005 STABILITY CLASS:
F ELEVATION:
10 METERS WIND SPEED (mph)
WIND DIRECTION N
NNE NE ENE E
WNW NW NNW TOTAL 1-3 4.50 7.00 11.25 9.25 7.75 15.50 11.50 4.75 4.50 3.25 2.50 3.00 4.50 3.25 1.00 5.50 94.50 4-7 30.00 22.50 19.50 14.50 63.75 67.25 68.25 75.25 35.25 13.00 24.50 8.25 7.25 5.25 17.25 31.50 503.25 8-12 13-18 19-24
>24 TOTAL 9.75 6.25 0.25 0.50 12.75 10.50 16.00 34.50 31.75 9.25 3.50 1.00 4.75 3.75 7.00 8.75 160.25 0.25 0.00 0.00 0.00 0.00 2.25 175.50 3.25 8.75 2.00 0.00 0.00 0.25 2.00 5.50 0.25 200.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.00 1.50 0.00 3.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 44.50 35.75 31.00 24.25 84.25 95.50 271.25 117.75 80.25 27.50 30.50 12.25 16.75 16.25 32.25 46.00 966.00 PERIOD OF CALM (HOURS): 4
33 of 36 HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:
STABILITY CLASS:
ELEVATION:
10 WIND DIRECTION 1-3 N
7.25 NNE 3.50 NE 6.00 ENE 10.25 E
7.75 ESE 9.75 SE 6.50 SSE 3.25 S
1.75 SSW 1.25 SW 0.75 WSW 0.75 W
2.50 WNW 2.00 NW 2.00 NNW 4.75 TOTAL.
62.75 3
JANUARY 1 THROUGH DECEMBER 31, 2005 G
METERS WIND SPEED (mph) 4-7 35.25 39.50 36.00 31.75 46.75 46.00 31.75 30.75 16.75 3.25 3.25 0.50 0.25 0.75 9.50 29.00 61.00 8-12 13-18 19-24
>24 TOTAL 2.25 3.25 1.00 0.00 1.50 1.00 2.75 3.50 6.75 2.25 0.00 0.00 0.00 0.00 0.25 4.50 29.00 0.00 0.00 0.00 0.00 0.00 0.00 0.25 0.00 0.75 1.25 0.00 0.00 0.00 0.00 0.00 0.00 2.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 44.75 46.25 43.00 42.00 56.00 56.75 41.25 37.50 26.00 8.00 4.00 1.25 2.75 2.75 11.75 38.25 462.25 PERIOD OF CALM (HOURS): 2
34 of 36.
HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:
JANUARY 1 THROUGH DECEMBER 31, 2005 STABILITY CLASS:
ALL ELEVATION:
10 METERS I WIND SPEED (mph)
WIND DIRECTION N
NNE NE ENE E
WNW NW NNW TOTAL 1-3 32.25 43.75 68.00 54.25 49.50 51.00 42.00 43.25 21.50 23.75 19.00 22.00 19.25 I24.50 23.75 33.75 571.50 4-7 174.75 148.00 222.50 162.00 258.50 221.75 203.00 279.25 196.50 110.00 132.00 66.75 60.00 59.00 84.75 142.50 2521.25 8-12 13-18 230.50 174.00 112.25 54.00 124.25 113.25 143.75 359.25 448.75 244.00 57.00 53.00 105.25 99.75 91.50 143.50 2554.00 145.25 609.25 26.25 7.75 24.50 27.50 206.25 145.50 421.00 181.25 9.75 11.00 28.00 41.50 102.75 89.50 2077.00 19-24 24.00 6.50 0.50 0.25 8.25 2.50 2.25 28.75 120.25 36.00 1.00 1.50 4.25 17.25 30.25 32.50 316.00
>24 TOTAL 4.00 3.00 0.25 0.00 1.50 0.00 0.00 0.75 5.75 3.50 0.75 4.00 3.25 4.00 6.75 13.75 51.25 610.75 984.i50 429.75 278.25 466.50 416.00 597.25 856.75 1213.75 598.50 219.50 158.25 220.00 246.C'0 339.75 455.,50 8091.00 PERIOD OF CALM (HOURS): 198.5
35 of 36 SECTION IV ADDITIONAL INFORMATION
- 1. Unplanned or Abnormal Releases One unplanned, monitored release occurred in 2005. See Section II, Additional Information.
The ODCM is in the form of two separate Wolf Creek Nuclear Operating Corporation (WCNOC) administrative procedures.
One of these procedures, the WCNOC "Offsite Dose Calculation Manual", AP 07B-003, Revision 5, is included with this report as Attachment I. The other procedure, "Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program),
AP 07E3-004, Revision 10, is included with this report as Attachment II.
- 3. Major Changes to Liquid, Solid, or Gaseous Radioactive Waste Treatment Systems There were no major changes to any of the radioactive waste treatment systems in 2005.
- 4. Land Use Census No new locations for dose calculation were identified during this report period.
- 5. Radwaste Shipments Twelve shipments of radioactive waste occurred during this report period.Section II, Subsection 3, of this report contains specific details regarding each shipment's mode of transportation and destination.
- 6. Inoperability of Effluent Monitoring Instrumentation No events occurred that violated ODCM Requirements Tables 2-2 and 3-2, liquid or gaseous effluent monitoring instrumentation.
- 7. Storage Tanks At no time during the year 2005 was there an event that led to liquid holdup tanks or gas storage tanks exceeding the limits of Technical Requirements Manual Sections 3.10.1 or 3.10.3.
Technical Specification requirements for the program are now covered by Technical Requirements Manual Section 3.10, "Explosive Gas and Storage Tank Radioactivity Monitoring."
36 of 36.
ATTACHMENTS TO WCGS ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - REPORT 29 Changes to the Wolf Creek Generating Station (WCGS) Offsite Dose Calculation Manual (ODCM) are submitted annually with the "Annual Radioactive Effluent Release Report". The WCGS ODCM is divided into two administrative procedures: WCNOC procedure AP 07B-003, "Offsite Dose Calculation Manual" and WCNOC procedure AP 07B-04, "Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program)".
Attachment I is AP 07B-003, Revision 5, "Offsite Dose Calculation Manual" Attachment II is AP 07B-004, Revision 10, "Offsite Dose Calculation Manual (Radiological Environmental Monitoring Program)"
Attachment IlIl is AP 31 A-1 00, Revision 5, "Solid Radwaste Process Control Program"