ML052310044

From kanterella
Jump to navigation Jump to search

Request for Additional Information for the Review of the Monticello Nuclear Generating Plant License Renewal Application
ML052310044
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 08/18/2005
From: Daniel Merzke
NRC/NRR/DRIP/RLEP
To: Conway J
Nuclear Management Co
Merzke, D., NRR/DRIP/RLEP, 415-3777
References
TAC MC6440
Download: ML052310044 (6)


Text

August 18, 2005 Mr. John T. Conway Site Vice President Nuclear Management Company, LLC 2807 West County Road 75 Monticello, MN 55362-9637

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MONTICELLO NUCLEAR GENERATING PLANT LICENSE RENEWAL APPLICATION (TAC NO. MC6440)

Dear Mr. Conway:

By letter dated March 16, 2005, Nuclear Management Company, LLC, (NMC or the applicant) submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 (10 CFR Part 54) to renew the operating license for Monticello Nuclear Generating Plant (MNGP) for review by the U.S. Nuclear Regulatory Commission (NRC). The NRC staff is reviewing the information contained in the license renewal application (LRA) and has identified, in the enclosure, areas where additional information is needed to complete the review.

These questions were discussed with your staff, Mr. Joe Pairitz, and a mutually agreeable date for this response is within 30 days from the date of this letter. If you have any questions, please contact me at 301-415-3777 or by e-mail at DXM2@nrc.gov.

Sincerely,

/RA/

Daniel J. Merzke, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No.: 50-263

Enclosure:

As stated cc w/encl: See next page

August 18, 2005 Mr. John T. Conway Site Vice President Nuclear Management Company, LLC 2807 West County Road 75 Monticello, MN 55362-9637

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE MONTICELLO NUCLEAR GENERATING PLANT LICENSE RENEWAL APPLICATION (TAC NO. MC6440)

Dear Mr. Conway:

By letter dated March 16, 2005, Nuclear Management Company, LLC, (NMC or the applicant) submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 (10 CFR Part 54) to renew the operating license for Monticello Nuclear Generating Plant (MNGP) for review by the U.S. Nuclear Regulatory Commission (NRC). The NRC staff is reviewing the information contained in the license renewal application (LRA) and has identified, in the enclosure, areas where additional information is needed to complete the review.

These questions were discussed with your staff, Mr. Joe Pairitz, and a mutually agreeable date for this response is within 30 days from the date of this letter. If you have any questions, please contact me at 301-415-3777 or by e-mail at DXM2@nrc.gov.

Sincerely,

/RA/

Daniel J. Merzke, Project Manager License Renewal Section A License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No.: 50-263

Enclosure:

As stated cc w/encl: See next page DISTRIBUTION: See next page ADAMS accession no.: ML052310044 Document Name: E:\\Filenet\\ML052310044.wpd OFFICE PM:RLEP LA:RLEP SC:RLEP NAME DMerzke MJenkins SLee (J. Eads for)

DATE 8/ 16 /05 8/ 15 /05 8/ 18 /05 OFFICIAL RECORD COPY

Monticello Nuclear Generating Plant cc:

Jonathan Rogoff, Esquire Vice President, Counsel & Secretary Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 U.S. Nuclear Regulatory Commission Resident Inspector's Office 2807 W. County Road 75 Monticello, MN 55362 Manager, Regulatory Affairs Monticello Nuclear Generating Plant Nuclear Management Company, LLC 2807 West County Road 75 Monticello, MN 55362-9637 Robert Nelson, President Minnesota Environmental Control Citizens Association (MECCA) 1051 South McKnight Road St. Paul, MN 55119 Commissioner Minnesota Pollution Control Agency 520 Lafayette Road St. Paul, MN 55155-4194 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Commissioner Minnesota Department of Health 717 Delaware Street, S. E.

Minneapolis, MN 55440 Douglas M. Gruber, Auditor/Treasurer Wright County Government Center 10 NW Second Street Buffalo, MN 55313 Commissioner Minnesota Department of Commerce 85 7th Place East, Suite 500 St. Paul, MN 55101-2198 Manager - Environmental Protection Division Minnesota Attorney Generals Office 445 Minnesota St., Suite 900 St. Paul, MN 55101-2127 John Paul Cowan Executive Vice President & Chief Nuclear Officer Nuclear Management Company, LLC 700 First Street Hudson, WI 54016 Nuclear Asset Manager Xcel Energy, Inc.

414 Nicollet Mall, R.S. 8 Minneapolis, MN 55401 Mr. James Ross Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Patrick Burke License Renewal Project Manager Monticello Nuclear Generating Plant Nuclear Management Company, LLC 2807 West County Road 75 Monticello, MN 55362-9637 Mr. Douglas F. Johnson Director, Plant Life Cycle Issues Nuclear Management Company, LLC 700 First Street Hudson, WI 54016

DISTRIBUTION: Letter to J. Conway, Re: RAI for review of Monticello LRA, Dated: August 18, 2005 ADAMS Accession No.: ML052310044 HARD COPY RLEP RF E-MAIL:

RidsNrrDrip RidsNrrDe G. Bagchi K. Manoly W. Bateman J. Calvo R. Jenkins J. Fair RidsNrrDssa RidsNrrDipm D. Thatcher R. Pettis G. Galletti C. Li K. Winsberg (RidsOgcMailCenter)

R. Weisman M. Mayfield A. Murphy S. Smith (srs3)

S. Duraiswamy Y. L. (Renee) Li RLEP Staff L. Raghavan M. Padovan A. Stone, RIII B. Burgess, RIII P. Lougheed, RIII R. Orlikowski, RIII T. Mensah OPA

Enclosure MONTICELLO NUCLEAR GENERATING PLANT LICENSE RENEWAL APPLICATION (LRA)

REQUEST FOR ADDITIONAL INFORMATION (RAI)

RAI B2.1.2-1 In lieu of the ASME Section XI examination requirements described in the GALL Report for the Reactor Vessel Stabilizer Bracket attachment welds (Examination Category B-K for welded attachments for vessels, piping pumps and valves), MNGPs current relief request allows visual examination of the accessible areas of those welds to provide adequate aging management during the extended period of operation. The NRC staff considers this an exception to the GALL Report for the ASME Section XI In-Service Inspection, Subsection IWB, IWC, and IWD Program. MNGP completed a VT-3 examination of the accessible areas of those welds during the 2005 refueling outage with no reportable indications recorded.

To support the NRC staff evaluation, the applicant is requested to describe details of the type of weld that is used for this attachment. Describe applicable examination requirements at the time of vessel manufacture (when the attachments were welded to the vessel) and, if readily available, provide applicable examination results. Describe inspections or examinations, if any, of the welds that have been performed since initial start-up of the plant, including the inspection or examination methodology and available results. Describe stressors (or absence thereof) that are experienced by the welds (e.g. mechanical or thermal forces, fatigue) during normal operation, and state, based on MNGPs operating history, whether the welds have experienced stressors different from the normal operating stressors. Provide a summary of industry operating experience, to the extent known by the applicant, that is related to failures or indicated defects in similar welds or to successful examination of similar welds. Provide any other additional information that MNGP considers appropriate for the NRC staff to consider in its evaluation of this proposed exception to the GALL Report's description for the ASME Section XI ISI, Subsection IWB, IWC, and IWD AMP.