ML051360123

From kanterella
Jump to navigation Jump to search
Enclosure 2, Attachment 6, Steam Dryer Weld Configurations, GE Information Document 26A6473, Revision 0, Dated April 11, 2005
ML051360123
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 04/11/2005
From: Tu T, Wainwright R
General Electric Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
26A6473, Rev 0
Download: ML051360123 (148)


Text

ENCLOSURE 2 ATTACHMENT 6 "Steam Dryer Weld Configurations," GE Information Document 26A6473, Revision 0, dated April 11, 2005

w GENuclearEnergy 26A6473 SH NO. I REV. 0 REVISION STATUS SHEET DOCUMENT TITLE STEAM DRYER WELD CONFIGURATIONS LEGEND OR DESCRIPTION OF GROUPS TYPE:

INFO DOC I

-DENOTES CHANGES FMF:

QUAD CITIES UNITS I&2 MPL NO:

PRODUCT

SUMMARY

SECTION 7 (s) B13-D005 SAFETY -RELATED CLASSIFICATION CODE N

REVISION I

C REVISION IC 0o RMCN05555 0

RMCN05555 4-

I I

I PRINTS TO MADE BY APPROVALS GENERAL ELECTRIC COMPANY 175 CURTNER AVENUE T. TU 01/24/05 T. TU 01/24/05 SAN JOSE CALIFORNIA 95125 CHKD BY:

ISSUED R. WAINWRIGHT 4/11/05 R.J. AHMANN ARP 11, 2005 CONT ON SHEET 2 MS WORD (12/5/02)

W GENuclearEneryyl 26A6473 SH NO. 2 REV. 0 I

SCOPE This Information Document in conjunction with the Steam Dryer Assembly drawing 124D 1518 provide weld configurations to assist vendor during the fabrication of Quad Cities Units I and 2 replacement steam dryers.

2 APPLICABLE DOCUMENTS 2.1 General Electric Documents.

The following documents form a part of this specification to the extent specified herein. The latest revision shall apply unless otherwise noted.

2.1.1 Supporting Documents

a. 124D 1518 - Steam Dryer
b. 26A6274 - Fabrication Specification for Steam Dryer Fabrication
c. 21 A2040 - Cleaning and Cleanliness Control
d. 26A6266 - Steam Dryer Design Specification
e. 26A6443 - Steam Dryer Installation Specification
f. 234C7153 - Steam Dryer Modification Drawing 2.2 Vendor Documents (US Tools and Dies - UST&D)
a. UST&D Allowable Weld Procedure 40GE (VPF #6827-103-000)
b. UST&D Allowable Weld Procedure 47GE (VPF #6827-104-000)
c. UST&D Allowable Weld Procedure 76GE (VPF #6827-105-000)
d. UST&D Allowable Weld Procedure 77GE (VPF #6827-106-000)
e. UST&D Allowable Weld Procedure 227GE (VPF #6827-107-000)
f.

UST&D Allowable Weld Procedure 233GE (VPF #6827-108-000)

g. UST&D Allowable Weld Procedure 246GE (VPF #6827-109-000) 2.3 Codes and Standards. The following codes and standards (issue in effect at the date of the purchase order, or as specified in this specification or its supporting documents) form a part of this specification to the extent specified herein.

2.3.1 ASME Boiler and Pressure Vessel Code

a.

Section III, Division 1, Nuclear Power Plants Components, Subsection NG, Core Support Structures, 1998 Edition, and Addenda through 2000 Addenda.

3 W'ELD CONFIGURATIONS

GENuclearEnergy 26A6473 SH NO. 3 REV. 0 3.1 Dryer Banks Table I - Dryer Bank Weld Configurations Note: Unless otherwise specified. all bevel anale tolerances are +30°/-100 WELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

WPS 100 Dryer Unit to Dryer VT, Surface PT 2.2.a, 2.2.b, Unit 2.2.c, 2.2.d, 2.2.e, 2.2.f (SEE 106)

(SEE 105)

(SEE 104)

(.072)

(SEE 103)

(SEE 101)

DETAILX G

(SEE 102)

(SEE 107)

(DRYER VANES NOT SHOWN FOR CLARITY)

V groove partial penetration and grind flush

W GENuclearEnergy 26A6473 SH NO. 4 REV. 0 WVELD LOCATION CONFIGURATION INSPECTION ALLOW~ABLE NO.

WPS 101 Dryer Unit to Dryer VT, Surfacc PT 2.2.a, 2.2.b, Unit (SEE 106) 2.2.c, 2.2.d, 2.2.e, 2.2.f

/SEE 100 DETAIL X E

(E107)

V groove partial penetration

-SINGLE PASS FULL LENGTH -

Weld Flush with Perforated Plate in areas where Bank to Bank Plate Weldment is necessary (Ref top 27.00 in) 102 Dryer Unit to Dryer VT, Surface PT 2.2.a, 2.2.b, Unit SEE 100 2.2.c, 2.2.d,

\\

-<DETAIL X

2.2.e, 2.2.f V groove partial penetration

w GENuclearEnergy 26A6473 SI-NO. 5 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

_W PS 103 Dryer Unit to Dryer VT, Surface PT 2.2.a, 2.2.b, Unit 2.2.c, 2.2.d, t(SEE 104) 2.2.e, 2.2.f SEE 100 DETAIL X (SEE 100)1<-

V groove partial penetration 104 Dryer Unit to Dryer VT, Surface PT 2.2.a, 2.2.b, Unit 2.2.c, 2.2.d, 2.2.e, 2.2.f SEE 100 DETAIL X (SEE 105)

V groove partial penetration and grind flush

w GENuclearEnergy 26A6473 SH NO. 6 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

wPs 105 Dryer Unit to Dryer VT, Surface PT 2.2.a, 2.2.b, Unit (SEE 104) 2.2.c, 2.2.d, 2.2.e, 2.2.f SEE 100 DETAIL X V groove partial penetration 106 Dryer Unit to Dryer VT, Surface PT 2.2.a, 2.2.b, Unit

/SEE 100 2.2.c, 2.2.d,

\\DETAIL X 2.2.e, 2.2.f (SEE 1 gov pri ation V groove partial penetration

W GENuclearEneirgy 26A6473 SFI NO. 7 l REV. 0 to 2.2.c, 2.2.d, 2.2.e, 2.2.f 108)

V groove partial penetration VT only on tack 1 INCH TACK WELD CENTERED Vane to Vane Tack Weld (Optional full length seal weld can be used, notch to notch - If used weld 107 inspection spec applies)

w GENuclearEnrey 26A6473 SH1 NO. 8 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

wPS 108 Dryer Unit to Dryer VT, Surface PT 2.2.a, 2.2.b, Unit X

a g

aEE 100 UnitL X2.2.c, 2.2.d 2.2.e, 2.2.f GRIND IF NEEDED F FITIENT WITH BRIDGE CASTING AND/OR TROUGH V groove partial penetration and grind flush 109 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7005) to Dryer HOODS Final PT 2.2.c, 2.2.d, Vanes 2.2.e, 2.2.f TEE BRACEX 2

lVANE END PLATES DETAIL A DETAIL A

~~~~~~Double bevel groove full penetration

w GENuclearEnerjy 26A6473 SH NO. 9 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 110 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7006) to Dryer Final PT 2.2.c, 2.2.d, Vanes (See 109) 2.2.e, 2.2.f Double bevel groove full penetration Ill Solid Gusset VT, Root and 2.2.a, 2.2.b, (234C7004) to Dryer RVANES Final PT 2.2.c, 2.2.d, Vanes 2.2.e, 2.2.f

<VANE END PLATES Double bevel grooves full penetration 112 Solid Gusset VT, Root and 2.2.a, 2.2.b, (234C7007) to Dryer (See 111)

Final PT 2.2.c, 2.2.d, Vanes 2.2.e, 2.2.f Double bevel groove full penetration

w GENucdearEnerqy 26A6473 Si-I NO. 10 REV. 0 WVELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WVS 113 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7005) to Dryer Final PT 2.2.c, 2.2.d, Vane 2.2.e, 2.2.f HOOD PLATE TEE BRACE

~.06 MAX.

Bevel groove full penetration argon gas backing 114 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7006) to Dryer (See 113)

Final PT 2.2.c, 2.2.d, Vane 2.2.c, 2.2.f Bevel groove full penetration argon gas backing 115 Hood Plate VT, Root and 2.2.a, 2.2.b, (234C7167) to Dryer (See 113)

Final PT 2.2.c, 2.2.d, Vane 2.2.e, 2.2.f Bevel groove full penetration argon gas backing 116 Hood Plate VT, Root and 2.2.a, 2.2.b, (234C7168) to Dryer (Sec 113)

Final PT 2.2.c, 2.2.d, Vane 2.2.e, 2.2.f Bevel groove full penetration argon gas backing 117 Flood Plate VT, Root and 2.2.a, 2.2.b, (234C7169) to Dryer (Sce 113)

Final PT 2.2.c, 2.2.d, Vane 2.2.e, 2.2.f Bevel groove full penetration argon gas backing

GENuclearEnetry 26A6473 SH NO. II REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOvABLE NO.

WvPS 118 Hood Plate VT, Root and 2.2.a, 2.2.b, (234C7170) to Dryer (Sce 113)

Final PT 2.2.c, 2.2.d, Vane 2.2.e, 2.2.f Bevel groove full penetration argon gas backing 119 Flood Plate VT, Root and 2.2.a, 2.2.b, (234C7171) to Dryer (Sec 113)

Final PT 2.2.c, 2.2.d, Vane 2.2.e, 2.2.f Bevel groove full penetration argon gas backing 120 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7005) to Solid OODS Final PT 2.2.c, 2.2.d, Gusset (234C7004) 2.2.c, 2.2.f l

SE122) e(.75)-

TE BRACEXS SOLID GUSSET

.06 MAX.

DETAIL A Double V groove full penetration 121 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7006) to Solid (Sce 120)

Final PT 2.2.c, 2.2.d, Gusset (234C7007) 2.2.e, 2.2.f Double V groove full penetration

w GENuclearEnergy 26A6473 Sl-NO. 12 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 122 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7005) to Hood F2X 60° Final PT 2.2.c, 2.2.d, (234C7167) 2.2.e, 2.2.f 2X 3°/

.06 MX

^

t (1.00)

DETAIL B Double V groove full penetration 123 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7005) to Hood (See 122)

Final PT 2.2.c, 2.2.d, (234C7168) 2.2.e, 2.2.f Double V groove full penetration 124 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7005) to Hood (See 122)

Final PT 2.2.c, 2.2.d, (234C7169) 2.2.e, 2.2.f Double V groove full penetration 125 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7006) to Hood (See 122)

Final PT 2.2.c, 2.2.d, (234C7 170) 2.2.e, 2.2.f Double V groove full penetration

GENuclearEneigy 26A6473 SH NO. 13 l

l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 126 Tee Brace VT, Root and 2.2.a, 2.2.b, (234C7006) to Hlood (See 122)

Final PT 2.2.c, 2.2.d, (234C7171) 2.2.e, 2.2.f Double V groove fuill penetration 127 Trough End Cap VT, Surface PT 2.2.a, 2.2.b, (234C6952P004) 2.2.c, 2.2.d, SIDE PLATES 2.2.e, 2.2.f

.06 MAX.

\\

i~See 130)/

130)30-DETAIL A DRAIN PIPE END CAP Bevel and fillet on the other side 128 Trough End Cap VT, Surface PT 2.2.a, 2.2.b, (234C6953P004)

(See 127) 2.2.c, 2.2.d, 2.2.e, 2.2.f Bevel and fillet on the other side 129 Trough End Cap VT, Surface PT 2.2.a, 2.2.b, (234C6954P004)

(See 127) 2.2.c, 2.2.d, 2.2.e, 2.2.f Bevel and fillet on the other side

w GENuclearEnetgy 26A6473 Sl-l NO. 14 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WI'S 130 Trough Side Plates to VT, Root and 2.2.a, 2.2.b, Drain Pipe Final PT 2.2.c, 2.2.d, (234C6952) 2.2.e, 2.2.f DRAIN PIPE

.06 MAX.

DETAIL B (END CAP NOT SHOWN)

Double V groove full penetration 131 Trough Side Plates to VT, Root and 2.2.a, 2.2.b, Drain Pipe (Scc 130)

Final PT 2.2.c, 2.2.d, (234C6953) 2.2.e, 2.2.f Double V groove full penetration 132 Trough Side Plates to VT, Root and 2.2.a, 2.2.b, Drain Pipe (Sec 130)

Final PT 2.2.c, 2.2.d, (234C6954) 2.2.e, 2.2.f Double V groove full penetration

w GENuclearEnergy 26A6473 SH NO. 15 REV. 0 WVELD LOCATION CONFIGURATION INSPECTION ALLOWABLE N O.

_W PS 133 Bridge (234C6955) to VT, Surface PT 2.2.a, 2.2.b, Side Plates 2.2.c, 2.2.d, (234C6952) 2.2.e, 2.2.f oBRIDGE

.2 3

SIDES SIDE PLATES DRAIN PIPE Fillet both sides 134 Bridge (234C6955) to VT, Surface PT 2.2.a, 2.2.b, Side Plates (Sec 133) 2.2.c, 2.2.d, (234C6953) 2.2.e, 2.2.f Fillet both sides 135 Bridge (234C6955) to VT, Surface PT 2.2.a, 2.2.b, Side Plates (Sce 133) 2.2.c, 2.2.d, (234C6954) 2.2.e, 2.2.f Fillet both sides

w GENuclearEneiry 26A6473 Sl-NO. 16 REV. 0 WELD)

LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

wps 136 Bridge (234C6955) to VT, Surface PT 2.2.a, 2.2.b, Side Plates 2.2.c, 2.2.d, (234C6952)

G 2.2.e, 2.2.f x

\\

\\SIDE PtATES Bevel groove and grind flush 137 Bridge (234C6955) to VT, Surface PT 2.2.a, 2.2.b, Side Plates (See 136) 2.2.c, 2.2.d, (234C6953) 2.2.e, 2.2.f Bevel groove and grind flush 138 Bridge (234C6955) to VT, Surface PT 2.2.a, 2.2.b, Side Plates (See 136) 2.2.c, 2.2.d, (234C6954) 2.2.e, 2.2.f Bevel groove and grind flush 139 Dryer Bank VT, Surface PT 2.2.a, 2.2.b, 140 (124D1559) to Bank 2.2.c, 2.2.d, 141 Trough (234C6952) 2.2.e, 2.2.f 142 143 144

i)V GENuclearEnetgy 26A6473 SHINO. 17 REV. 0 141

\\-150

GENuclearEnergy 26A6473 SH NO. 18 REV. 0 DRYER UNITS -

2X (DRYER VANE NOT SHOWN)

Dryer Bank (I 24D 1560) to Bank Trough (234C6953)

VT, Surface PT 2.2.c, 2.2.d, 2.2.e. 2.2.f

w GENuclearEnergy 26A6473 SI-H NO. 19 REV. 0 t-162 2.2.c, 2.2.d, 2.2.e, 2.2.f Trough (234C6954)

w GENuclearEnergy 26A6473 SH NO. 20 l REV. 0 VELD I

LOCATION CONFIGURATION INSPECTION I ALLOWABLE NO.

I ws So6 Fillet Weld 171 NOT USE 172 NOT USE 173 Mid Bank Cover VT, Root and 2.2.a, 2.2.b, Plate (234C7243)

Final PT 2.2.c, 2.2.d 2.2.e. 2.2.f

GENuclearEneriy 26A6473 SI-NO. 21 REV. 0 Center Bank Cover Plate (234C7242) 2.2.c, 2.2.d, 2.2.e, 2.2.f BANK TROUGH Fillet partial penetration All Around Alternate Configuration Bevel Weld (3/8" ( 45 Deg) Permitted where geometry does not permit proper fillet VT, Root and Surface PT if

w GENucdearEnergy 26A6473 SH NO. 22 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 175 Outer Bank Cover VT, Surface PT 2.2.a, 2.2.b, Plate (234C7244)

(See 174) 2.2.c, 2.2.d, Fillet partial penetration 2.2.e, 2.2.f Alternate Configuration VT, Root and Surface PT if Bevel Weld (3/8" @ 45 Deg) Permitted where geometry does not Groove is used permit proper fillet 176 Mid Bank Cover VT, Surface PT 2.2.a, 2.2.b, Plate (234C7243)

DRYER BANK 2.2.c, 2.2.d, NOT SHOWN)

NDERSIDE WELD 2.2.e, 2.2.f A

t S

OT SHOWN)

BANK TROUGH -

Fillet partial penetration all around

w GENuclearEnergy 26A6473 SF-! NO. 23 REV. 0 WELD LOCATION CONFIGURATION INSPECTION I ALLOWABLE NO.

I I

WPS 177 Center Bank to Mid Bank (3 Configurations)

Outside: VT Only Due to Accessibility 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.c, 2.2.f Inside: VT, Root and Final PT MID BANK Configuration I Double Fillet Partial Penetration FILL TO FLUSH ASNEEDED FOR WELD ACCESS Configuration 2 Fillet to Flush Outer Side - Groove Full Penetration Inside

GENuclearEnergy 26A6473 SH NO. 24 REV.O0 CONFIGURATION ALTERNATE COWJ~URAflON

,F0L TO FLUSH GRIND TO PROVIDVE)D A FULL PENETRATION WED Configuration 3 Fillet to Flush Outer Side - Groove Full Penetration Inside Bank Only Due to Accessibility 2.2.c, 2.2.d, 2.2.e, 2.2.f Inside: VT, Root and Final PT OUTER

w GENuclearEneigy 26A6473 SH NO. 25 REV. 0 WELD ILOCATION I

CONFIGURATION l INSPECTION l,LLOWSBLE NO.

r AS NEEDED N

FOR WELD ACCESS Fillet to Flush Outer TAPER OFF TEE TRU R

AS NEEDED FOR MMD ACCESS Configuration 2 Side - Groove Full Penetration Inside ALTFRMATE CONFIGURATION GR540OTO PROVIDI! HFLD A FULL PENETRATION MNLO Configuration 3 Fillet to Flush Outer Side - Groove Full Penetration Inside

GENuclearEnergy 26A6473 SH NO. 26 REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWABLE INO.

WPS 179 Outer Bank to Cover VT, Root and 2.2.a, 2.2.b, Plate (234C7260)

OUTERWK Final PT 2.2.c, 2.2.d, M MAX 2.2.e, 2.2.f1 A

~~2XW0X0' 1V-COVER PLATE DETAIL A Double V groove full penetration 180 Outer Bank to Corner VT, Root and 2.2.a, 2.2.b, Stiffener (234C7083)

ITERW Final PT 2.2.c, 2.2.d, MA 2.2.e, 2.2.f STIVTENERs DETAIL A Double V groove full penetration 181 Cover Plate VT, Root and 2.2.a, 2.2.b, (234C7260) to Upper 75V OVER PLATE Final PT 2.2.c, 2.2.d, Support Ring 2.2.e, 2.2.f UPPER SUPPORT RING Fillet partial penetration

GENuclearEnergy 26A6473 SH NO. 27 REV. 0 VT, Root and SIFnFENERS Final PT (234C7083) to Upper Support Ring 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f UPPER SUPPORT RING Corner Stiffener (234C7083) to Curved Cover Plate (234C7260)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f

GENuclearEneirgy 26A6473 SH NO. 28 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWvABLE NO.

WPS CURVED COVER PLATE W

i (1.00)

CORNER STIFFENER DETAIL A Double V Groove Full Penetration 184 Corner Stiffener PAss VT, Root and 2.2.a, 2.2.b, (234C7083) to Upper

/

STIFR Final PT 2.2.c, 2.2.d, Support Ring 2.2.e, 2.2.f (Backside)

X ar L

O c tio n_1 ROW Location 1

GENuclearEneigy 26A6473 SF1 NO. 29 REV. 0 WELD I

LOCATION CONFIGURATION i I LOEs NO.

I WPS Location 2 FM S"wPIR IFTLUSI VffVR0 Location 3 Flare Bevel Groove Weld Partial Penetration Note: For all locations Weld wt'idth is best effort uniformn throughout. Weld Location I is recommendled weld size dathnm throughout wield 184.

w GENuclearEneirgy 26A6473 SH NO. 30 REV. 0

w GENucdearEnergy 26A6473 Sl1 NO. 31 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

WPS 186 Cover Plate VT, Root and 2.2.a, 2.2.b, (234C7260) To

/

Final PT 2.2.c, 2.2.d.

Upper Support Ring 2.2.e, 2.2.f (Backside)

WT RIN SUPOTR Partial Penetration Flare Bevel Groove Weld 187 Corner Stiffener lSHVWLD VT, Root and 2.2.a, 2.2.b, (234C7083) to Outer

\\

RCUT Final PT 2.2.c, 2.2.d, Bank Trough -

2.2.e, 2.2.f Mounting block AS MUND K (Front side)

Jl

<FACE CC VtER STFt INO_8U V groove Best Effort Full Penetration

GENuclearEnergy 26A6473 SH NO. 32 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 188 Corner Stiffener VT, Root and 2.2.a, 2.2.b, (234C7083) to Final PT 2.2.c, 2.2.d, Mounting Block 2.2.e, 2.2.f (Bottom)

&W R'

Fillet Partial Penetration 189 Vane Cap Doubler VT, Root and 2.2.a, 2.2.b, Plate Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f

" iun OUIERHOCOWE 000CUiE Y/2" Fillet All Around COI

e GENuclearEneiry 26A6473 SIH NO. 33 REV. 0 3.2 Tie Beam. Supports etc.

Table 2 - Tie Beam, Supports etc. Weld Configurations Note: Unless otherwise specified, all bevel angle tolerances are +30°/-10° WELD LOCATION CONFIGURATION l INSPECTION I ALLOWABLE NO.1 I

I WPS 200 Tie Beam Support (234C6967) to Dryer Bank (124D1559)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d.

2.2.e, 2.2.f Fillet partial penetration all around Tie Beam Support VT, Root and 2.2.a, 2.2.b, (234C6967) to Dryer (See 200)

Final PT 2.2.c, 2.2.d, Bank (I24D 1560) 2.2.e, 2.2.f Fillet partial penetration all around Tie Beam Support VT, Root and 2.2.a, 2.2.b, (234C6967) to Dryer (Sce 200)

Final PT 2.2.c, 2.2.d, Bank (124D1561) 2.2.e, 2.2.f Fillet partial penetration all around

GENuclearEnergy 26A6473 SF1 NO. 34 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE N O.

_W P S 203 Tie Beam Support VT, Root and 2.2.a, 2.2.b, (234C6967) to Tie Final PT 2.2.c, 2.2.d, Support DYRAKO 32.2.c, 2.2.f7 (I 05E3886P028)

DRYER BANK TOP 12.c22f 1TIE BEAM SUPPORT TIE BEAM SUPPORT TIE BEAM (3X 3X 3M8VM Flare-bevel partial penetration 204 Tie Beam Support VT, Root and 2.2.a, 2.2.b, (234C6967) to Tie

/

Final PT 2.2.c, 2.2.d.

Support DRYERBANKTOP

.3 S

2.2.e, 2.2.f (105E3886P28)

TTIE BEAM SUPPORT TIE BEAM SUPPORT IE BEAM (3 X 3 X 318W)

Fillet partial penetration

w GENuclearEnergy 26A6473 SH NO. 35 REV.0 WELD LOCATION CONFIGURATION INSPECTION

.ALLOV.ABLE NO.

WPS 205 Lifting Rod Support VT, Root and 2.2.a. 2.2.b, (234C6969) to Bank TIEBEAM Final PT 2.2.c, 2.2.d, (124D1561)

ENDCCAP2.2.e, 2.2.f p

2 LFTING ROD DR'ER BANK SUPPORT Fillet partial penetration 206 Lifting Rod Support VT, Root and 2.2.a, 2.2.b, (234C6969) to Bank TEBEAM&

Final PT 2.2.c, 2.2.d (124D1561)

ENDCAp 2.2.e, 2.2.f TOP OF DRYER BANK

/

t l\\

LFTING ROD DRYER BANK SUPPORT Fillet partial penetration

GENuclearEnergy 26A6473 SH NO. 36 l

l REV. 0 WVELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

_WPS 207 Lifting Rod Support VT, Root and 2.2.a, 2.2.b, (234C6969) to Bank E CAM M

Final PT 2.2.c, 2.2.d, (I124D 1561)

EDCP2.2.e, 2.2.f TOP OF DRYER BANK 5

s

/

vLFTING ROD DRYER BANK LSUPPORT

.38R Flare bevel partial penetration 208 Lifting Rod Support VT, Surface PT 2.2.a, 2.2.b, (234C6969) to Tie T38 2.2.c, 2.2.d Beam E2.2.e, 2.2.f (105E3886P026)

X TOP OF---"

DRYER BANK I

en LFTING ROD DRYER BANK SUPPORT

~~~Fillet partial penetration both sides_________

W GENuclearEnergy 26A6473 SH NO. 37 l REV.0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

vps 209 Tie Beam Cap VT, Surface PT 2.2.a, 2.2.b, (105E3886P049) to TI EM2.2.c, 2.24d Tie Beam 3X3X318W) 2.2.c, 2.2.f l

-.25 MIN.l Single groove weld all around 210 Trough Support VT, Root and 2.2.a, 2.2.b, (234C6968) to Final PT 2.2.c, 2.2.d, Trough (234C6952)

BANKTROUGH 2.2.c, 2.2.f TROUGH SUPPORT 4 X 6 X 1/4W TUBING Fillet weld all around 211 Trough Support VT, Root and 2.2.a, 2.2.b, (234C6968) to (Scc 210)

Final PT 2.2.c, 2.2.d, Trough (234C6953) 2.2.e, 2.2.f Fillet weld all around

GENuclearEnergy 26A6473 S-I NO. 38 REV.O0 WVELD LOCATION CONFIGURATION INSPECTION ALLOWVAIBLE NO.

VPS 212 Trough Support VT, Root and 2.2.a, 2.2.b, (234C6968) to (See 210)

Final PT 2.2.c, 2.2.d, Trough (234C6954) 2.2.e, 2.2.f Fillet weld all around 213 Trough Support VT, Root and 2.2.a, 2.2.b, (234C6968) to Final PT 2.2.c, 2.2.d, Tubing BANK TROUGH 2.2.e, 2.2.f (234C6946P006)

TROUGH SUPPORT 4X 6X 1I4WTUBING Fillet weld all around 214 Trough Support VT, Root and 2.2.a, 2.2.b, (234C6968) to (See 213)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946PO07)

Fillet weld all around 215 Trough Support VT, Root and 2.2.a, 2.2.b, (234C6968) to (See 213)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P008)

Fillet weld all around

GENuclearEneiry 26A6473 SH NO. 39 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 216 Tee Foot (234C7024)

VT, Root and 2.2.a, 2.2.b, to Tubing Final PT 2.2.c, 2.2.d, (234C6946P006)

SOLID GUSSET 2.2.e, 2.2.1 TEE FOOT l

J TUBING (4 X 6 X 1/4W)

Bevel groove and fillet weld all around 217 Tee Foot (234C7024)

VT, Root and 2.2.a, 2.2.b, to Tubing (See 216)

Final PT 2.2.c, 2.2.d, (234C6946P007) 2.2.e, 2.2.f Bevel groove and fillet weld all around 218 Tee Foot (234C7024)

VT, Root and 2.2.a, 2.2.b, to Tubing (Sec 216)

Final PT 2.2.c, 2.2.d, (234C6946P008) 2.2.e, 2.2.f Bevel groove and fillet weld all around

W GENuclearEnetgy 26A6473 SH NO. 40 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

Wps 219 Tee Foot (234C7024)

VT, Root and 2.2.a, 2.2.b, to Solid Gusset Final PT 2.2.c, 2.2.d, (234C7004) 2.2.c, 2.2.f SOLID GUSSET TUBING (4 X 6 X 1/4W)

Bevel groove and fillet weld all around 220 Tee Foot (234C7024)

VT, Root and 2.2.a, 2.2.b, to Solid Gusset Final PT 2.2.c, 2.2.d, (234C7007) 2.2.e, 2.2.f (See 219)

Bevel groove and fillet weld all around

wY GENuclearEnergy 26A6473 SIH NO. 41 REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWVAIBLE NO.

eWps 221 Y Frame Connector VT, Surface PT 2.2.a, 2.2.b, (234C6966) to Tie 2.2.c, 2.2.d, Beam TE BEAM 2.2.e, 2.2.f (105E3886P026)

(3X3X318W)

V FRAME CONNECTOR (4 X4 X1 WM Fillet weld all around 222 Y Frame Connector VT, Surface PT 2.2.a, 2.2.b, (234C6966) to TIE BEAM 2.2.c, 2.2.d, Tubing (3X3X38)2.2.e, 2.2.1' (105E3886P027)

FRAME CONNECTOR TUBFeG (4 X4 X 1/W)

Fillet weld all around

w GENuclearEnergy 26A6473 SI-I NO. 42 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWVAB3LE N O.

_W__

_~P S

223 Y Frame Connector VT, Surface PT 2.2.a, 2.2.b, (234C6966) to T2E BEAM 2.2.c, 2.2.d, Tubing 3X3X3M 2.2.e, 2.2.f (105E3886P024)

V FRAME CONNECTOR Fillet weld all around (weld casting notches first) 224 Y Frame Connector VT, Surface PT 2.2.a, 2.2.b, (234C6966) to TIE BEAM 2.2.c, 2.2.d, Tubing (3X3X38)2.2.e, 2.2.f' (105E3886P025)

V FRAME CONNECTOR TUBeds (4 X4 X 1/2W Fillet weld all around (weld casting notches firt

W GENuclearEnergy 26A6473 Sl-I NO. 43 l REV.O0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

Wps 225 Frame Connector VT, Surface PT 2.2.a, 2.2.b, (234C6965) to Tie 2.2.c, 2.2.d Beam

.3L2.2.e, 2.2.f (105E3886P028)

T BEAM (4 X 4 X 1/2W)

JFRAME CONNECTOR Fillet weld all around both sides 226 Frame Connector VT, Surface PT 2.2.a, 2.2.b, (234C6965) to 2.2.c, 2.2.d, Tubing TIEBE2 2B2Ef (105E3886P027)

(3 X 3 X 318M Q

C TUBING (4X4X12W)

FRAME CONNECTOR Fillet weld all around

W GENuclearEnergy 26A6473 SH NO. 44 REV.O0 WELD LOCATION CONFIGURATION INSPECTION ALLO\\VABLE N O.

_W__

_~p s

227 Frame Connector VT, Surface PT 2.2.a, 2.2.b, (234C6965) to 2cBEAM

,222 2.22d, Tubing (3X3X38)2.2.c, 2.2.f

((105E3886Po24)

I J/838V (4 X 4 X FRM W

E CONNECTOR Fillet weld all around (weld casting notches first) 228 Guide Rod Block VT, Root and 2.2.a, 2.2.b, (234C6948) to TUBING Final PT 2.2.c, 2.2.d, Tubing (X 4 X1/2W) 2.2.e, 2.2.17 (105E3886P025)

\\

\\

3 SIDES UIDE ROD BLOCK Fillet 3 sides

w GENuclear Energy 26A6473 SH NO. 45 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWvABLE NO.

WPS 229 Guide Rod Block VT, Root and 2.2.a, 2.2.b, (234C6948) to ING Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (I 05E3886P025)

.06 MAX.

UIDE ROD BLOCK DETAIL A V groove 230 Tubing VT, Root and 2.2.a, 2.2.b, (105E3886P024) to (4X4x1r2W Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P006)

,,38D (4X 6X114W)

Fillet partial penetration 231 Tubing VT, Root and 2.2.a, 2.2.b, (l05E3886P024) to (See 230)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P007)

Fillet partial penetration

w GENuclearEnergy 26A6473 SI-NO.46 REV. 0 WELD)

LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 232 Tubing VT, Root and 2.2.a, 2.2.b, (I05E3886P024) to (Sce 230)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P008)

Fillet partial penetration 233 Tubing VT, Root and 2.2.a, 2.2.b, (105E3886P024) to(4 X4X12W)

Tubing (4X4X12V ia T2.2.c, 2.24 (234C6946P006) 2 (4X6X 114W)

Flare-bevel partial penetration 234 Tubing VT, Root and 2.2.a, 2.2.b, (105E3886P024) to (Sec 233)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P007)

Flare-bevel partial penetration 235 Tubing VT, Root and 2.2.a, 2.2.b, (105E3886P024) to (See 233)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P008)

Flare-bevel partial penetration

W GENuclearEnergy 26A6473 SH NO. 47 REV. 0 WVELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 236 Trough Support VT, Root and 2.2.a, 2.2.b, (234C6949) to Upper Final PT 2.2.c, 2.2Ad Support Ring 2.2.e, 2.2.1f (234C6946)

TROUGH SUPPORT UPPER SUPPORT RING Fillet all around partial penetration (Best Effort Continuous weld to allow for outer hood plate fit-up and associated weld) 237 Trough Support VT, Root and 2.2.a, 2.2.b, (234C6950) to Upper Final PT 2.2.c, 2.2.d Support Ring 2.2.e, 2.2.f (234C6946)

(See 237)

Fillet all around partial penetration (Best Effort Continuous weld to allow for outer hood plate fit-up and associated weld)

W GENuclearEnergy 26A6473 SH NO. 48 REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWvABLE NO.

WPS 238 Center Bank to VT, Root and 2.2.a, 2.2.b, Trough Support Final PT 2.2.c, 2.2.d, (234C6949)

DRYER BANK 2.2.e, 2.2.f (DRYER UNIT NOT SHOWN)

TROUGH SUPPORT UPPER SUPPORT RING Fillet all around partial penetration (Best Effort Continuous veld to allowv for outer hood plate fit-up and associated weld) 239 Mid Bank to Trough VT, Root and 2.2.a, 2.2.b, Support (234C6950)

Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.17 (See 238)

Fillet all around partial penetration (Best Effort Continuous weld to allow for outer hood plate fit-up and associated weld)

W GENuclearEnergy 26A6473 S1-1 NO. 49 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE N O.

_W P S 240 Outer Bank to Upper VT, Root and 2.2.a, 2.2.b, Support Ring Final PT 2.2.c, 2.2.d, (234C6946)

OUTER DRYER BANK 2.2.e, 2.2.f (DRYER UNIT NOT SHOWN)

UPPER SUPPORT RING Fillet all around partial penetration (Best Effort Continuous weld all around to allow for outer hood plate fit-up and associated weld)

W GENuclearEnergy 26A6473 SI-I NO. 50 l REV. 0 3.3 End Panels, Plates etc.

Table 3 - End Panels, Plates etc Weld Configurations Note: Unless othenvise specified, all bevel angle tolerances are +30°/-10O WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

_PS 300 NOT USE 301 Outer Bank End Plate (234C7255)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f

Y GENuclearEnergy 26A6473 SHNO. 51 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWvABLE N O.

_W P S OUTER HOOD

(.0

.06 MAX.

NU OUTER BANK

(

END PLATE (1.00)

V Groove full penetration 302 Outer Bank End Plate VT, Root and 2.2.a, 2.2.b, (234C7255)

(See 301 for detail)

Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f V Groove best effort penetration 303 Outer Bank End Plate VT, Root and 2.2.a, 2.2.b, (234C7255)

(.25 MIN)N Final PT 2.2.c, 2.2.d, OUTER HOO LTER BANK 2.2.e, 2.2.f END PLATVT, Surface PT as applicable on inside cover

\\weld areas

.00) \\

/WELD

.50 MNV \\303 Fillet partial penetration to flush with outer hood end plate -

Inside Cover weld as permitted on areas below the vane bank (trough side plates, trough support castings, ctc.)

GENuclearEnergy 26A6473 S-I NO. 52 REV. 0 Mid Bank End Plate (234C7254)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f

W GENuclearEnetry 26A6473 SI-NO. 53 REV. 0 CONFIGURATION MID HOOD

.06 MAX.

VT, Root and Final PT (234C7257) to Mid Bank End Plate 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f OUTER BANK VT, Surface PT as applicable on inside cover weld areas

GENuclearEnergy 26A6473 SF1 NO. 54 l REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

WvPS

(.25 M1N)N

.50>

.50 4ID BANK END PLATE MID FILLERy m

< WELD

(.50)305 Outside: V Groove best effort full penetration Y/2" depth best effort to flush with plate Inside: Cover weld as permitted on accessible areas.

306 Mid Bank End Plate VT, Root and 2.2.a, 2.2.b, (234C7254)

(See 304 for detail)

Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f V Groove best effort penetration 307 Mid Bank End Plate VT, Root and 2.2.a, 2.2.b, (234C7254)

(25MIN)N Final PT 2.2.c, 2.2.d, l

2.2.e, 2.2.f VT, Surface PT as applicable on inside cover WELD 3weld areas END PLATE

(.50 MI~N) ~307 As found V Groove full penetration (continues onto trough) fill flush with mid bank end plate. Inside Cover weld as permitted on areas below the vane bank (trough side plates, trough support castings, etc.)

wY GENuclearEnegy 26A6473 SI-I NO. 55 l REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 308 NOT USE 309 Center Bank End VT, Root and 2.2.a, 2.2.b, Plate (234C7253)

Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f 312 309 z

HOOD CENTER BANK END PLATE V Groove full penetration

GENucdearEnergy 26A6473 SI-I NO. 56 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE No.

I I

WPs 310 Center Filler (234C7256)

MID BANK VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f ENTER FILLER VT, Surface PT as applicable on inside cover weld areas

-CENTER BANK END PLATE BANK END PLATE

<WELD

<\\310 Outside: V Groove best effort full penetration 2A" depth best effort to flush with plate.

Inside: Cover weld as permitted on accessible areas.

W GENuclearEnerqy 26A6473 SH NO. 57 REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WvPS 311 Center Bank End VT, Root and 2.2.a, 2.2.b, Plate (234C7253)

(See 309 for detail)

Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f V Groove best effort full penetration 312 Center Bank End VT, Root and 2.2.a, 2.2.b, Plate (234C7253)

(.25 Final PT 2.2.c, 2.2.d

)N 2.2.e, 2.2.f7 ENTER BANK

(.so)

<VT, Surface PT CENTS-as applicable on END PLATEWELD inside cover

-(.50MIN)

N

< 312 weld areas As found V Groove full penetration (continues onto trough) fill flush with center bank end plate. Inside Cover weld as permitted on areas below the vane bank (trough side plates, trough support castings, etc.)

w GENuclearEnergy 26A6473 SH NO. 58 REV. 0

W GENuclearEnergy 26A6473 SH NO. 59 REV. 0 CONFIGURATION Fillet partial penetration all around Alternate Configuration TO WELD 313

.50 CLOSURE Outside: Fillet All Around (3/8" Min)

Inside: 3/8" Min Depth Groove with cover fillet to flush with VT, Root and Final PT (234C7257) 2.2.c, 2.2.d, 2.2.e, 2.2.f OUTER BANK VT, Surface PT as applicable on BANK inside cover fillet areas

GENuclearEnetgy 26A6473 SH NO. 60 REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

_WPS Fillet partial penetration (3 sides Inside and Out)

Alternate Configuration NSIDE COVER FILLET AS PERMITTED

.50 ID FILLER

.50 MID BANK ASSEMBLY (TROUGH) 45.0' WELD \\(.25 MIN) 314

/

(.50)1\\

Single Bevel best effort full penetration with inside cover fillet as permitted 315 Center Filler Plate MID BANKVT, Root and 2.2.a, 2.2.b, (234C7256)

Final PT 2.2.c, 2.2.d, CENTER FILLER 2.2.e, 2.2.f VT, Surface PT as applicable on inside cover fillet areas ENTER BANK END PLATE

GENuclearEnergy 26A6473 Sl-NO. 61 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

WPS Fillet partial penetration (3 Sides Inside and Out)

Alternate Configuration NSIDE COVER FILLET PAS ERMITTED

.50j ENTER FILLER CENTER BANK ASSEMBLY (TROUGH)/

\\

315

/

{0[

Single Bevel best effort full penetration with inside cover fillet as permitted 316 Mid Closure MIDBANKENDPLA VT, Surface PT 2.2.a, 2.2.b, (234C7259) 2.2.c, 2.2.d, 2.2.e, 2.2.f PPER SUPPORT RING I~E 31 (INSIDE)%1 AROUND AND INSIDE ID CLOSURE

e GENuclearEDeigy 26A6473 SH NO. 62 l REV. 0 WELD [ LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

II WPS MID HOOD ENO I DETAIL A Fillet All Around partial penetration Altcrnatc Configuration WELD i31t MID HOOD END I Outside: Fillet All Around (3/8" Min)

Inside: 3/8" Min Depth Groove with cover fillet to flush with Plate

w GENucdearEneigy 26A6473 SH NO. 63 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 317 Mid Closure VT, Root and 2.2.a, 2.2.b, (234C7259) Backside CLOSURE Final PT 2.2.c, 2.2.d, to Upper Support 2.2.e, 2.2.f Ring E1 Y/ WSUPPORT RSNG As ou d fla e tb EFFORT

\\LSH tH tPPORT WItG As found flare bevel groove weld

W GENuclearEneirgy 26A6473 SH NO. 64 l REV. 0 WELD I LOCATION I

CONFIGURATION INSPECTION ALLOWABLE 318 Center Closure (234C7258) to Backside to Upper Support Ring VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f t SUPPORT RING As found flare bevel groove weld

w GENuclearEnergy l 26A6473 SH NO. 65 l REV. 0 WELD LOCATION I

CONFIGURATION l INSPECTION I ALLOWVABLE NO.

I____

J WPS 319 Outer End Cover to Outer Bank Assembly End Plate VT, Surface PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f L ________________________

a I

.1

W GENuclearEnetgy 26A6473 SH NO. 66 REV. 0 WELD I LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

II WPS t VANE ASSEMBLY.END2 PLATE s io BEST EFFORT FULL LENGTH ON INEIDE OUTER I DETAIL A Double Fillet (Overlap Pernitted)

Outside: 3/8" Fillet Inside: 1/4" Fillet or to flush with Perforated Plate Alternate Configuration Best Effort Full Penetration with Perforated Plate side cover weld

wY GENuclearEnergy 26A6473 SH NO. 67 l l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE N O.

_W P S 320 Outer End Cover to VT, Root and 2.2.a, 2.2.b, Mid Flood Outer Tee I HOODINNERPLATE Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.17 X

(4 inUTR END COVER GRIND OUTSIDE TO FLUSH A

(SEE 124)

MID HOOD OUTER TE Configuration 1 Double Bevel Full Penetration Configuration 2 Single Bevel Full Penetration With Cover Fillets (Best Effort Full Length Fillet on inside)

w GENuclearEnergy 26A6473 SH NO. 68 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION I ALLOWABLE NO.

IUWPS 321 End Cover Transition Piece (234C7275) to Mid Hood Tee (234C7005)

Horizontal Weld VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f Double Bevel Full Penetration

GENuclearEnetgy 26A6473 SHT NO. 69 REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 322 End Cover Transition VT, Root and 2.2.a, 2.2.b, Piece (234C7275) to Final PT 2.2.c, 2.2.d, Mid Hood Tee I

HOOD IN PLATE 2.2.e, 2.2.f (234C7005) Vertical Weld8 A

t t(450.,1 LOSURE PLATE TRANSmON DPIECE GRIND OUTSIDE TO FLUSH is

/\\

\\(SEE 124)

MID HOOD OUTER TE Double Bevel Full Penetration

GENuclearEnergy 26A6473 SH NO. 70 l REV. 0 WELD LOCATION I

CONFIGURATION INSPECTION I ALLOWABLE NO.

I WPS 323 End Cover Transition Piece (234C7275) to Outer End Cover Horizontal and Vertical Weld VT, Root and Final PT

'</1 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f Full Penetration Double Groove Weld

w GENuclearEnergy 26A6473 SH NO. 71 REV. 0 WEL I

LOCATION CONFIGURATION l INSPECTION I ALLOWABLE N O.

I__

I W P S 324 Center End Cover to Mid Bank Assembly End Plate VT, Surface PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.c, 2.2.f SEE 327'

GENuclearEnergy 26A6473 SH NO. 72 REV. 0 WELD LOCATION I

CONFIGURATION INSPECTION ALLOWABLE NO.

vr I

WS BANK VANE ASSEMBLY E PLATE 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f CENTER END I DETAIL A Double Fillet (Overlap Permitted)

Outside: 3/8" Fillet Inside: 1/4" Fillet or to flush with Perforated Plate Alternate Configuration Best Effort Full Penetration with Perforated Plate side cover weld

GENuclearEnerpy 26A6473 SI-I NO. 73 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

Wps 325 Center End Cover to VT, Root and 2.2.a, 2.2.b, Center Bank Outer ENTER END COVER Final PT 2.2.c, 2.2.d, H-lood Plate S

I 2.2.e, 2.2.f (234C7168)

(4A 38

\\

CENTER HOOD PLA

.38 Configuration 1 Double Bevel Full Penetration Configuration 2 Single Bevel Full penetration with Cover Fillets (Best Effort Full Length Fillet on inside)

w GENuclearEnergy 26A6473 SH NO. 74 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 326 End Cover Transition VT, Root and 2.2.a, 2.2.b, Piece (234C7275) to VXsEAMM.Y<^NO FMA Final PT 2.2.c, 2.2.d, Center Bank Outer Fo~rr 2.2.e, 2.2.f Hood Plate (234C7168)

Horizontal Weld Duee FulW PeetaAtion Double Bevel Full Penetration

GENuclearEnergy 26A6473 SH NO. 75 REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 327 End Cover Transition VT, Root and 2.2.a, 2.2.b, Piece (234C7275) to LOSURE PLATE TRANSITION Final PT 2.2.c, 2.2.d, Center Bank Outer

.5oo (45)

PIECE 2.2.e, 2.2.f Hood Plate (234C7168) Vertical

.500 Weld

~

CENTER HOODPLTS 37 Double Bevel Full Penetration 328 End Cover Transition VT, Root and 2.2.a, 2.2.b, Piece (234C7275) to Final PT 2.2.c, 2.2.d, Center End Cover 2.2.e, 2.2.f Horizontal and Vertical Weld CLOSURE PLATETRANSMON PIECEn 320

__________________FullPenetrationDoubleGrooveWeld________

GENuclearEneirgy 26A6473 SH NO. 76 l

l REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

W________~PS 329 Center End Cover VT, Root and 2.2.a, 2.2.b, Plate (Lower) weld to CENTERCOVE SEE3" Final PT 2.2.c, 2.2.d, Mid Support Ring WE 0

2.2.e, 2.2.f and Trough Support MICOE Castings z

5

_<<ENERTROUGH END COVER PL-A 1\\<

OR SUPPO)RT RlNG

-D SEE DETAILA^

GENuclearEnergy 26A6473 SH NO. 77 REV. 0 WELD I LOCATION CONFIGURATION INSPECTION I ALLOWABLE NO.

I WPS DETAIL A Fillet Inside and Out

GENuclearEnergy 26A6473 SHF NO. 78 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

Wps 330 Center End Cover VT, Root and 2.2.a, 2.2.b, Plate (Lower) weld to Final PT 2.2.c, 2.2.d, Floor Plate 2.2.e, 2.2.f Fillet Inside and Out

GENuclearEnergy 26A6473 SH NO. 79 l

l REV. 0 oELD I

LOCATION CONFIGURATION INSPECTION I ALLOWABLE 331 Center End Cover Plate (Lower) weld to trough side plate VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f Best Effort Full Penetration Groove weld or Fillet Inside and Out

W GENuclearEneirgy 26A6473 SH NO. 80 l REV. 0 VELD I LOCATION 1

CONFIGURATION l INSPECTION I ALLOWABLE NO.

I_________

I____________________________

WPS 332 Center End Cover Plate (Lower) weld to Center Bank Lower Vane Hook VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f Best Effort full penetration groove weld with Inside Fillet Or Fillet Inside and Out

W GENuclearEneirgy 26A6473 SH NO. 81 REV. 0 WELD i

LOCATION I

CONFIGURATION INSPECTION I ALLOWABLE 333 Floor Plate to Floor Plate Horizontal Seam Weld VT, Root and Final PT RYER VANE PERFORATED PLATE I

WELD 333 LOOR PLATE OUTER LOOR PLATE INNER Double Bevel Full Penetration 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f VT, Surface PT for backing weld (Alternate Configuration)

Alternate Configuration

.06 MAX Single Bevel Full Penetration With Backing Weld

GENuclearEnergy 26A6473 SH NO. 82 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 334 Floor Plate to Vane ENTER BANK VANE ASSEMBLY VT, Surface PT 2.2.a, 2.2.b, Bank Lower [look ENTERCOVER Outside 2.2.c, 2.2.d, Weld 2.2.e, 2.2.f 7ID COVER TEE VT, Root and Final PT Inside 35 F r P FLOOR PTATE k

L r

Hk SLD 334 115 7NOTE:

FILLET SIZES MINIMUM VAELOWER HOOK 1/4 Inch or more fillet outside 3/8 inch or more fillet outside 335 Floor Plate to Vane VT, Surface PT 2.2.a, 2.2.b, Bank Lower Hook (See 334)

Outside 2.2.c, 2.2.d, Weld (opposite side) 2.2.e, 2.2.f 1/4 Inch or more fillet outside VT, Root and 3/8 inch or more fillet outside Final PT Inside

w GENuclearEnetgy 26A6473 SI-I NO. 83 REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WVPS 336 Vertical beam Lattice INNER FLOOR PLATEy RT1CALTIE BEAM VT, Root and 2.2.a, 2.2.b, to Floor Plate Weld Final PT 2.2.c, 2.2.d, (Typical) 2.2.e, 2.2.f UTR FLOOR PLATE X s s

muBOTH SIDES NOTE: FILLET WELD SIZE

______________________Min 3/8 inch Fillet Inside and Out All Around

GENuclearEnergy 26A6473 SH NO. 84 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

_WPS 337 Mid Cover Tee CENTER COVER-VT, Root and 2.2.a, 2.2.b, (234C7279) to Floor Final PT 2.2.c, 2.2.d, Plate Weld 2.2.c, 2.2.f 60.0 0r WEL 33 2\\

38

\\

\\\\ELDE 337

\\

/

I lFILLET SIZE MID COVER TEE UTER FLOOR PLATE Min 3/8 Inch Fillet Inside and Out 338 Mid Cover Tee VT, Root and 2.2.a, 2.2.b, (234C7279) to Center (See 337)

Final PT 2.2.c, 2.2.d, Cover 2.2.e, 2.2.f Double Groove Weld Full Penetration

GENuclearEnergy 26A6473 SF1 NO. 85 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE N O.

_W P S 339 Center Cover To D 2 R

VT, Root and 2.2.a, 2.2.b, Center Bank End Final PT 2.2.c, 2.2.d, Plates (Side Weld) 2.2.e, 2.2.f WMI 3OVE WELD 3 40 YWHERE APP.

MID COVR WLD 343RIE

w GENuclearEnergy 26A6473 SH NO. 86 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

eWPS Dobe tWe

(/END RATE DETAIL A Double Fillet Weld (3/8" Min)

GENuclearEnergy 26A6473 S-I NO. 87 REV. 0 WELD I LOCATION I

CONFIGURATION INSPECTION I ALLOWABLE N O.

I_ _ _ _ _ _ _ _ _ _ _

_I__

W P S 340 Center Cover To Upper Stiffener (234C7288)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.c, 2.2.f Double Groove Full Penetration

GENucearEnegry 26A6473 SH NO. 88 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 341 Upper Stiffener YID AREA VT, Root and 2.2.a, 2.2.b, (234C7288) to Vane Final PT 2.2.c, 2.2.d, Bank End Plate 2.2.e, 2.2.f (Sides)

Fillet All Around where applicable Inside and Out (3/8")

COZ

GE NucarEney 26A6473 SH NO. 89 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE N O.

_W PS 342 Upper Stiffener cwso PPERSTFFENER VT, Root and 2.2.a, 2.2.b, (234C7288) to Vane Final PT 2.2.c, 2.2.d, Bank End Plate (Top) 2.2.e, 2.2.f DETAIL AA MO"N

(.06)

MA-X iX G

CETRCOVER CENTER OM-DETAIL A Groove Weld Top Side Ground Flush Fillet (3/8") Underside

GE NudcarEney 26A6473 SH NO. 90 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 343 Mid Cover Tee VT, Root and 2.2.a, 2.2.b, (234C7279) to Center EFinal PT 2.2.c, 2.2.d, Bank End Plate /

_2.2.e, 2.2.f Lower Hook (105E3886) 343 WELD AREA

GENuclearEnergy 26A6473 SH NO. 91 REV. 0 VELD I LOCATION CONFIGURATION INSPECTION I ALLOWABLE NO.

[

I

_PS

"-AMID COVER TEE Fillet Weld Inside and Out (3/8) and All Around as applicable per geometry

WY GENuclearEnergy 26A6473 SH NO. 92 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION I ALLOWABLE NO.

4 I

Wps 344 Mid Bank End Plate to Mounting Block (234C6947) Lower Weld VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f

.50- -1 j

ID BANK END PLATE WELD OUNTING BLOCK Double Fillet Partial Penetration

w GENuclearEnergy 26A6473 SH! NO. 93 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOVABLE NO.

WPS 350 Center Reinforcing UVT, Root and 2.2.a, 2.2.b, Plate to Center Bank TEE Final PT 2.2.c, 2.2.d, Perforated Plate 2.2.e, 2.2.f Seam Weld

/

\\

\\

-CHER RSFORCFM5 TEE MD MTERLpE OF 4.4 MA" AUL AROL

-ECE h

\\

\\

/\\

/

DETALA

/ <

XPLATE

GENuclearEnergy 26A6473 SH NO. 94 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS ENTER VANE ASSEMBLY (ED PLATE SEE WELD l101 ERFORAED ll l

l t

4<

LWElD

¶010 CENTER REINFORCING PLATE DETAIL A

'GRIND FLUSH IF NEEDED Double Bevel Full Penetration

k0 GENuclearEnerqy 26A6473 SH NO. 95 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOVWABLE NO.

WPS 351 Center Reinforcing

.38 RREINFOCIN VT, Surface PT 2.2.a, 2.2.b, Plate Tee to Center 2.2.c, 2.2.d, Plenum Vertical 4x4 2.2.e, 2.2.f Post 3.00-

.25 BEST EFFORT x4 VERTICAL POST 1/4' Fillet Partial Penetration All Around

S GENuclearEnergy 26A6473 SI-I NO. 96 REV. 0 3.4 Upper Support Ring and Base Plate Table 4 - Upper Support Ring and Base Plate Weld Configurations Note: Unless otherwise snecified. all bevel angle tolerances are +30°/-10O WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE 400 Tubing VT, Root and 2.2.a, 2.2.b, (234C6946P002) to Final PT 2.2.c, 2.2.d, Tubing 2.2.c, 2.2.f (234C6946P005)

(.50)

TUBN BING SECTION A-A

.06 AX DETAIL B V groove full penetration all around and grind flush 401 Mounting Block VT, Root and 2.2.a, 2.2.b, (234C6947P001) to (See 400)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P002)

V groove full penetration all around and grind flush 402 Mounting Block VT, Root and 2.2.a, 2.2.b, (234C6947P001) to (See 400)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P004)

V groove full penetration all around and grind flush

GENucdearEnergy 26A6473 SH NO. 97 l l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

_WPS 403 Mounting Block VT, Root and 2.2.a, 2.2.b, (234C6947P002) to (See 400)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P002)

V groove full penetration all around and grind flush 404 Mounting Block VT, Root and 2.2.a, 2.2.b, (234C6947P002) to (See 400)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P003)

V groove full penetration all around and grind flush 405 Guide Rod Block VT, Root and 2.2.a, 2.2.b, (234C6948P001) to (See 400)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P003)

V groove full penetration all around and grind flush 406 Guide Rod Block VT, Root and 2.2.a, 2.2.b, (234C6948P001) to (See 400)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P004)

V groove full penetration all around and grind flush 407 Tubing VT, Surface PT 2.2.a, 2.2.b, (234C6946P006) to 2.2.c, 2.2.d, Mounting Block 2.2.e, 2.2.f (234C6947PO0I)

MOUNTING BLOCK TUBE,4X6X1/4W Fillet partial penetration all around

GENuclearEnergy 26A6473 SH NO. 98 REV. 0 LOCATION CONFIGURATION INSPECTION ALLOWABLE eePS Tubing VT, Surface PT 2.2.a, 2.2.b, (234C6946P006) to (See 407) 2.2.c, 2.2.d, Mounting Block 2.2.e, 2.2.f (234C6947P002)

Fillet partial penetration all around Tubing (234C6946P002) to VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f Tubing (234C6946P007)

Fillet partial penetration all around 410 Tubing VT, Root and 2.2.a, 2.2.b, (234C6946P005) to (See 409)

Final PT 2.2.c, 2.2.d, Tubing 2.2.e, 2.2.f (234C6946P008)

Fillet partial penetration all around

w GENuclearEnergy 26A6473 SH NO. 99 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

vws 411 Base Plate Joints VT, Root and 2.2.a, 2.2.b, (234C7104)

G 2X 60*

Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f 4'0

.06 MAX.

DETAIL A DoubleV groove full penetration and grind flush both sides

GENuclearEneiry 26A6473 S-I NO. 100 REV. 0 3.5 Bottom Skirt Table 5 - Bottom Skirt Weld Configurations NInV-+ I ?nlnoc r^th

-;fI 0 a

,11 hnl onnip tnlprnnrnc nrp 4J..OI1 nO StI N

Jl l

WI 33 I

Ja LI%.I"I 1

I.in (II I

4U "lt I V'1 (I"Id 11 twl(4II.4 481 "I ~

I l-I WVELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 500 Beam Support VT, Root and 2.2.a, 2.2.b, (234C7100)

(-35)

Final PT 2.2.c, 2.2.d,

(.)

2.2.e, 2.2.f g~z Z

t28) 30 66-

.06 MA DETAIL A V groove full penetration 501 Beam Support VT, Root and 2.2.a, 2.2.b, (234C7 100)

Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f 60"

.06 MAX.

DETAIL B V groove full penetration

w GENuclearEnergy 26A6473 SHINO. 101 I REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWvABLE NO.

VPS 502 NOT USE 503 Latch Box VT, Surface PT 2.2.a, 2.2.b, (234C7103) 7

\\

<3 SIDES 2.2.c, 2.2.d, 3G )

2.2.e, 2.2.f l

60*

j~.0 MAX I

DETAIL A V groove full penetration and grind flush 504 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P009) to Final PT 2.2.c, 2.2.d, Upper Support Ring MP

~2.2.e, 2.2S1 (234C6946)

FR (SEE SI)B W

SO2T CPTEE DETAIL A Flare-bevel and fillet partial penetration

GENuclearEnepgy 26A6473 SH NO. 102 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 505 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P0 10) to Final PT 2.2.c, 2.2.d, Upper Support Ring (See 504) 2.2.e, 2.2.f (234C6946)

Flare-bevel and fillet partial penetration 506 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P01 1) to (See 504)

Final PT 2.2.c, 2.2.d, Upper Support Ring 2.2.e, 2.2.f (234C6946)

Flare-bevel and fillet partial penetration 507 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P012) to (See 504)

Final PT 2.2.c, 2.2.d, Upper Support Ring 2.2.e, 2.2.f (234C6946)

Flare-bevel and fillet partial penetration 508 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P013) to (See 504)

Final PT 2.2.c, 2.2.d, Upper Support Ring 2.2.e, 2.2.f (234C6946)

Flare-bevel and fillet partial penetration 509 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P0 14) to (See 504)

Final PT 2.2.c, 2.2.d, Upper Support Ring 2.2.e, 2.2.f (234C6946)

Flare-bevel and fillet partial penetration

GENuckearEneigy 26A6473 S-I NO. 103 l REV. 0 l

WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 510 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P009) to Final PT 2.2.c, 2.2.d, Upper Support Ring SUPPORT 2.2.e, 2.2.f (234C6946)

RING (SEE 516) B D

ID SKIRT CAP TEE DETAIL A Fillet partial penetration 511 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P010) to (See 510)

Final PT 2.2.c, 2.2.d, Upper Support Ring 2.2.e, 2.2.f (234C6946)

Fillet partial penetration 512 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P01 1) to (See 510)

Final PT 2.2.c, 2.2.d, Upper Support Ring 2.2.e, 2.2.f (234C6946)

Fillet partial penetration 513 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P012) to (See 510)

Final PT 2.2.c, 2.2.d, Upper Support Ring 2.2.e, 2.2.f (234C6946)

Fillet partial penetration 514 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P0 13) to (See 510)

Final PT 2.2.c, 2.2.d, Upper Support Ring 2.2.e, 2.2.f (234C6946)

Fillet partial penetration

GENuclearEniergy 26A6473 SHlNO. 104 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 515 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P0 14) to (Sce 510)

Final PT 2.2.c, 2.2.d, Upper Support Ring 2.2.e, 2.2.f (234C6946)

Fillet partial penetration 516 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P009) to

.oeWOx MAX -

SIRTCAPTEE Final PT 2.2.c, 2.2.d, Skirt Plate 2.2.e, 2.2.f (234C6945P01 5) 2X13 SlaRT PLATE DETAIL B Double V groove full penetration 517 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P0 10) to (See 516)

Final PT 2.2.c, 2.2.d, Skirt Plate 2.2.e, 2.2.f (234C6945P0 16)

Double V groove full penetration 518 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P01 I) to (See 516)

Final PT 2.2.c, 2.2.d, Skirt Plate 2.2.e, 2.2.f (234C6945P017)

Double V groove full penetration 519 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P0 12) to (See 516)

Final PT 2.2.c, 2.2.d, Skirt Plate 2.2.e, 2.2.f (234C6945P018)

Double V groove full penetration 520 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P0 13) to (Scc 516)

Final PT 2.2.c, 2.2.d, Skirt Plate 2.2.e, 2.2.f (234C6945P019)

Double V groove full penetration

GENuclearEnergy 26A6473 SH NO. 105 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WvPS 521 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P014) to (See 516)

Final PT 2.2.c, 2.2.d, Skirt Plate 2.2.e, 2.2.f (234C6945P020)

Double V groove full penetration 522 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P0 15) to 2.2.c, 2.2.d, Base Plate

(.0M 2.2.e, 2.2.f (234C7104)

WELD M

-\\ S H

RT PLATE

(.1O6MIN BASE PLAT-

-0MI (234C7104)

_________________Double bevel Partial Penetration with cover Fillet 523 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P016) to (See 522) 2.2.c, 2.2.d, Base Plate 2.2.e, 2.2.f (234C7 104)

Double bevel Partial Penetration with cover Fillet 524 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945 PO]7) to (See 522) 2.2.c, 2.2.d Base Plate 2.2.e, 2.2.f (234C7 104)

Double bevel Partial Penetration with cover Fillet 525 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P0 1 8) to (See 522) 2.2.c, 2.2.d, Base Plate 2.2.e, 2.2.f

____(234C7104)

Double bevel Partial Penetration with cover Fillet

W GENuclearEnergy 26A6473 SH NO. 106 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

Wps 526 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P019) to (Sec 522) 2.2.c, 2.2.d, Base Plate 2.2.e, 2.2.f (234C7104)

Double bevel Partial Penetration with cover Fillet 527 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P020) to (See 522) 2.2.c, 2.2.d, Base Plate 2.2.e, 2.2.f (234C7104)

Double bevel Partial Penetration with cover Fillet 528 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P015) to (Same as 522) 2.2.c, 2.2.d, Base Plate 2.2.e, 2.2.f (234C7104)

Double bevel Partial Penetration with cover Fillet 529 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P016) to (Same as 523) 2.2.c, 2.2.d, Base Plate 2.2.e, 2.2.f (234C7104)

Double bevel Partial Penetration with cover Fillet 530 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P0 17) to (Same as 524) 2.2.c, 2.2.d, Base Plate 2.2.e, 2.2.f (234C7104)

Double bevel Partial Penetration with cover Fillet 531 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P018) to (Same as 525) 2.2.c, 2.2.d, Base Plate 2.2.e, 2.2.f (234C7104)

Double bevel Partial Penetration with cover Fillet 532 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P019) to (Same as 526) 2.2.c, 2.2.d, Base Plate 2.2.e, 2.2.f (234C7104)

Double bevel Partial Penetration with cover Fillet

GENuclearEneiry 26A6473 SHNO. 107 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

_WPS 533 Skirt Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945P020) to (Same as 527) 2.2.c, 2.2.d, Base Plate 2.2.e, 2.2.f (234C7104)

Double bevel Partial Penetration with cover Fillet 534 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P009) to 2X6 Final PT 2.2.c, 2.2.d, Drain Channel

/

RM 2.2.e, 2.2.f (234C7086)

M :MAX.

ID CAW&LDETAIL A Double V groove full penetration 535 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P01 I) to (Sce 534)

Final PT 2.2.c, 2.2.d, Drain Channel 2.2.e, 2.2.f (234C7086)

Double V groove full penetration 536 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P0 12) to (See 534)

Final PT 2.2.c, 2.2.d, Drain Channel 2.2.e, 2.2.f (234C7086)

Double V groove full penetration 537 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P0 13) to (See 534)

Final PT 2.2.c, 2.2.d, Drain Channel 2.2.e, 2.2.f (234C7086)

Double V groove full penetration 538 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P014) to (Sec 534)

Final PT 2.2.c, 2.2.d, Drain Channel 2.2.e, 2.2.f (234C7086)

Double V groove full penetration

w GENuclearEnetgy 26A6473 SH NO. 108 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

_W PS 539 Skirt Plate VT, Root and 2.2.a, 2.2.b, (234C6945P015) to Final PT 2.2.c, 2.2.d, Drain Channel PPER SUPPOR RING 2.2.e, 2.2.f (234C7086)

/

\\

SKIRT PIATE

.06 MAX ID

/DETAIL A

Double V groove full penetration 540 Skirt Plate VT, Root and 2.2.a, 2.2.b, (234C6945P0 17) to (See 539)

Final PT 2.2.c, 2.2.d, Drain Channel 2.2.e, 2.2.f (234C7086)

Double V groove full penetration 541 Skirt Plate VT, Root and 2.2.a, 2.2.b, (234C6945P018) to (See 539)

Final PT 2.2.c, 2.2.d, Drain Channel 2.2.e, 2.2.f (234C7086)

Double V groove full penetration 542 Skirt Plate VT, Root and 2.2.a, 2.2.b, (234C6945P019) to (See 539)

Final PT 2.2.c, 2.2.d, Drain Channel 2.2.e, 2.2.f (234C7086)

Double V groove full penetration 543 Skirt Plate VT, Root and 2.2.a, 2.2.b, (234C6945P020) to (Sec 539)

Final PT 2.2.c, 2.2.d, Drain Channel 2.2.e, 2.2.f (234C7086)

Double V groove full penetration

GENuclearEn7eiy 26A6473 SHNO. 109 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 544 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P009) to 2

Final PT 2.2.c, 2.2.d, Support Beam PPER SUPPORT RING 2.2.e, 2.2.f (234C7100) 2X30 l

ISKIRTCTEE.06 MAX.

ID DETAIL A Double V groove full penetration 545 Skirt Cap Tee VT, Root and 2.2.a, 2.2.b, (234C6945P010) to (See 544)

Final PT 2.2.c, 2.2.d, Support Beam 2.2.e, 2.2.f (234C7 100)

Double V groove full penetration 546 Skirt Plate VT, Root and 2.2.a, 2.2.b, (234C6945P015) to 2 6 Final PT 2.2.c, 2.2.d, Support Beam PPER SUPPORT RfNG 2.2.e, 2.2.f (234C7100)

SKIRT PLATE

.06 MAX.

\\

/

SPPORTBEAM ID DETAIL A Double V groove full penetration 547 Skirt Plate VT, Root and 2.2.a, 2.2.b, (234C6945P0 16) to (Sce 546)

Final PT 2.2.c, 2.2.d, Support Beam 2.2.e, 2.2.f (234C7100)

Double V groove full penetration I

w GENuclearEnergy 26A6473 SHNO. 110 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS_____

548 Drain Channel VT, Surface PT 2.2.a, 2.2.b, (234C7086) to Base (SEE 528)

RAIN CHANNEL 2.2.c, 2.2.d, Plate (234C7104)

S

/

2.2.e, 2.2.f SKSKIR PLATE (SEE 522) t/

V 25v*

BAE PLATE 549 Beamn Support VT, Surface PT 2.2.a, 2.2.b, (234C71 00) to Base

.25v

/

SEE 546) 2.2.c, 2.2.d, Plate (234C7104)

(SEE 501) 2.2.e, 2.2.f BASE PLATE-\\6 SKIRT PLATE (SEE 547)_

X SKIRTPLATE / _S SUPPORT

_2F SEE 500)

Fillet weld

w GENuclearEnerjy 26A6473 SH NO. I lII REV. 0 LOCATION Gusset Support (234C7102) to Base Plate (234C7104)

Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f IRT PLATE SUPPORT GUSSET PLATE Bevel groove partial penetration and grind flush (234C7102) to Base Plate (234C7104) 2.2.c, 2.2.d, 2.2.e, 2.2.f PLATE SUPPORT GUSSET PLATE Fillet

W GENuclearEnergy 26A6473 SHNO. 112l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

_WPS 552 Gusset Support VT, Surface PT 2.2.a, 2.2.b, (234C7102) to Base S

GSKIRT PlATE 2.2.c, 2.2.d, Plate (234C7104)

UPPORT GUSSET 2.2.e, 2.2.f BSE PLATE Fillet 553 Lower Guide Rod VT, Root and 2.2.a, 2.2.b, Support (234C7 101)

SKIRT PLATE Final PT 2.2.c, 2.2.d, to Base Plate 2.2.e, 2.2.f (234C7104)

LOWER GUIDE ROD SUPPORT BASE PLATE

.25lr

_________________Bevel groove partial penetration and grind flush

W GENucdearEnrgy 26A6473 SHNO. 113 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 554 Lower Guide Rod VT, Surface PT 2.2.a, 2.2.b, Support (234C7101)

SKIRTPLATE 2.2.c, 2.2.d, to Base Plate LOWER GUIDE 2.2.e, 2.2.f (234C7104)

ROD SUPPORT BASE PLATE Fillet 555 Lower Guide Rod VT, Surface PT 2.2.a, 2.2.b, Support (234C7101 )

SKIRT PLATE 2.2.c, 2.2.d, to Base Plate LOWER GUIDE 2.2.e, 2.2.f (234C7104) 2ROD SUPPORT

/ ASE PLATE Fillet

W GENuclearEneirgy 26A6473 SHINO. 114 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

vWPS 556 Latch Box VT, Surface PT 2.2.a, 2.2.b, (234C7103)

.2 2.2.c, 2.2.d,

.25 a2.2.e, 2.2.f

),/K(.38)

/

D LTCH BOX (234C713)

Fillet weld all around, both sides 557 Cover Plate VT, Surface PT 2.2.a, 2.2.b, (234C6945) to MOUTING BLOCK 2.2.c, 2.2.d, Mounting Block 2.2.e, 2.2.f (234C6947)

Bvlg pti PLATE (23C%5PO1)

Bevel groove partial penetration all around

GENuclearEneiy 26A6473 SHNO. 115 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

WPS 558 Drain Channel VT, Root and 2.2.a, 2.2.b, (234C7086) to Upper

.38 V DRAIN CHANNEL Final PT 2.2.c, 2.2.d, Support Ring OD2.2.e, 2.2.f (234C6946)

(SEE 534)

\\

(SEE 600)

UPPER SUPPORT RING Fillet partial penetration 559 Drain Channel VT, Root and 2.2.a, 2.2.b, (234C7086) to

.38 v DRAIN CHANNEL Final PT 2.2.c, 2.2.d, Mounting Block OD 2.2.e, 2.2.f (234C6947)

(SEE534)

ID

';(SEE 6~00)

MOUNTING BLOCK Fillet partial penetration 560 NOT USE

w GENuclearEnergy 26A6473 SH1 NO. 116 REV. 0 WELD I LOCATION 1

CONFIGURATION l INSPECTION l ALLOWABLE NO.

_I W

VPS 561 Beam Support (234C7100) to Support Beam Doubler Plate (234C7301)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f 1/4'" Min - 3/8" Max Fillet Partial Penetration All Around

w GENuclearEnergy 26A6473 SH NO. 117 REV. 0 WELD I LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

I Iwps 562 Support Beam Doubler Plate (234C7301) to Upper Support Ring (234C6946)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f WELD 682 WERE APPLICABLE UPPER '

RING 1/4" Min -3/8" Max Fillet Partial Penetration All Around Where Applicable

GENuclearEneigy 26A6473 SH NO. 118 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 563 Skirt Cap Tee LATCH BO VT, Surface PT 2.2.a, 2.2.b, (234C6945P0 13-KIRT CAP TE 2.2.c, 2.2.d, P0 14) to Mounting 2.2.e, 2.2.f Block (234C6947)

(Latch Box Area) or WELD 563

/

AMOUNTING BLOCK LRND FOR LATCH BOX FITMENT (GRINDING OF LATCH BOX CORNER ALSO PERMITTED)

Partial Penetration Fillet CGOf

GENuclearEneiry 26A6473 SFINO.II9 l l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 564 Support Beam WELD eS VT, Root and 2.2.a, 2.2.b, Doubler Plate AS FOUND SUPPORT Final PT 2.2.c, 2.2.d, (234C7301) to Upper x

2.2.e, 2.2.f Support Ring (OD Side) (234C6946)

I A

\\<

M AS FON I

I VUPPORT ET BI Partial Penetration Flare Bevel Groove With Best Effort Cover Fillet 565 Support Beam VT, Root and 2.2.a, 2.2.b, Doubler Plate (Sec 564)

Final PT 2.2.c, 2.2.d, (234C7301) to Upper 2.2.e, 2.2.f Support Ring (ID Side) (234C6946)

Partial Penetration Flare Bevel Groove With Best Effort Cover Fillet

wY GENuclearEnergy 26A6473 SHNO. 120 REV. 0 3.6 Drain Channel Weld Configuration Table 6 - Drain Channel Weld Configurations Nn*f T In lpcc ntfhprvice cneefirlA n iI hevel nnolp tnlprqnfepc nre 4+iA1/

I1 no WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 600 Drain Channel VT, Root and 2.2.a, 2.2.b, (234C7086) 4X Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f l

r1

(, tA

~(.3 5

600 W

~~.06 MAX.>g, DETAIL A V groove full penetration

GENuclearEneiry 26A6473 SHNO. 121 REV. 0 3.7 Miscellaneous Weld Configuration Table 7 - Miscellaneous Weld Configurations Note: Unless othervise snecified. all bevel angle tolerances are +30°/- 10° VELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 700 NOT USE 701 Outer Trough Cover VT, Surface PT 2.2.a, 2.2.b, Assembly Weld Top WBD701>

2.2.c, 2.2.d, (234C7244) 2.2.e, 2.2.f TROGCOVER P.ATE(OUTER)

WELD 702

_Duu PerABOTiOM CONFIURATION Double Bevel Full Penetration

w GENuclearEneirgy 26A6473 SII NO. 122 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

MaPS 702 Outer Trough Cover (See 701)

VT, Surface PT 2.2.a, 2.2.b, Assembly Weld 2.2.c, 2.2.d, Lower (234C7244)

Double Bevel Full Penetration 2.2.e, 2.2.f 703 Mid Trough Cover (See 701)

VT, Surface PT 2.2.a, 2.2.b, Assembly Weld Top 2.2.c, 2.2.d, (234C7243)

Double Bevel Full Penetration 2.2.e, 2.2.f 704 Mid Trough Cover (Sec 701)

VT, Surface PT 2.2.a, 2.2.b, Assembly Weld 2.2.c, 2.2.d, Lower (234C7243)

Double Bevel Full Penetration 2.2.e, 2.2.f 705 Center Trough Cover (See 701)

VT, Surface PT 2.2.a, 2.2.b, Assembly Weld Top 2.2.c, 2.2.d, (234C7242)

Double Bevel Full Penetration 2.2.e, 2.2.f 706 Center Trough Cover (Sec 701)

VT, Surface PT 2.2.a, 2.2.b, Assembly Weld 2.2.c, 2.2.d, Lower (234C7242)

Double Bevel Full Penetration 2.2.e, 2.2.f 707 Mounting Block Jack VT, Surface PT 2.2.a, 2.2.b, Bolt Ratchet Notch NOTCH 2.2.c, 2.2.d, Cover (234C6947) 2.2.e, 2.2.f

GENuclearEnetgy 26A6473 SHNO. 123 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WMs NOTCH COWfR PIA-TZ Bevel All Around Partial Penetration 708 Latch Bail to Pointer VT, Root and 2.2.a, 2.2.b, Weld (234C6956)

Bevel Weld Two Sides Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f 709 Latch Pin Tack Weld VT 2.2.a, 2.2.b, (234C6956)

Tack Weld Only 2.2.c, 2.2.d, 2.2.e, 2.2.f

w GENucearEneigy 26A6473 SH NO. 124 I REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 710 Lifting Rod Nut VT 2.2.a, 2.2.b, (234C7236) to 2.2TAT AT Top 2.2.c, 2.2.d, Mounting Block 2.2.e, 2.2.f (234C6947) Tack Weld START AT BOTTOM WELD 710 UFT ROD TACK WELD AREA Tack Weld Only 711 NOT USE 712 NOT USE 713 NOT USE COC

GENudearEneigy 26A6473 SH NO. 125 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 714 Frame Post Foot VT, Root and 2.2.a, 2.2.b, (234C7303) to Frame Final PT 2.2.c, 2.2.d, Post Foot uLD71e 2.2.e, 2.2.f ALL AROUND 38 MIN PNTR OSUPFOOT RXG2 A

\\B~tSIDES EIJTERSUlPPORT RING WELD715 VE

~AROUNID

S GENuclearEneigy 26A6473 SH NO. 126 REV. 0 WELD LOCATION CONFIGURATION INSPECTION I ALLOWABLE NO.

I Wps UPPER SUPPORT RING CENTER CROSS MEMBER V Groove weld Both sides

k0 GENuclearEnergy 26A6473 SH NO. 127 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 715 Frame Post Foot VT, Root and 2.2.a, 2.2.b, (234C7303) to Upper RVRCAL Final PT 2.2.c, 2.2.d, Support Ring Center EPOT 2.2.e, 2.2.f Cross Member (234C6946)

ALL AROUND DM~ SIDES l

I 3m I I

~!.

POS FOOTFTRt SUPPORT RING CENTER CROSS UCLWER Fillet Weld 3/8 All Around 716 Frame Post Foot VT, Root and 2.2.a, 2.2.b, (234C7303) to (Sec 715)

Final PT 2.2.c, 2.2.d, Vertical Frame 2.2.e, 2.2.f Member Fillet Weld 3/8 All Around (105E3886P024)

w GENuclearEnerqy 26A6473 SH NO. 128 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

II WPS 717 Trough Bridge Extension (234C7323P002) to Gusset (Single Bevel Plate Side) Typical VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f 3/8 Min Fillet Partial Penetration

w GENuclearEnery 26A6473 SHNO. 129 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

_______________________________WpS 718 Trough Bridge VT, Root and 2.2.a, 2.2.b, Extension Final PT 2.2.c, 2.2.d, (234C7323P001) to Az 2.2.e, 2.2.f Gusset (Double Bevel Plate Side)

{rnwI 3/8 Min Fillet Partial Penetration

w GENuclearEnergy 26A6473 SHNO. 130 REV. 0 WELD LOCATION CONFIGURATION INSPECTION IALLOWABLE NO.

IU::

PS 719 Trough Bridge Extension (234C7323P002) to Trough Bridge (Single Bevel Side)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f TROUGH BRIDGE EXTENSION 719 Single Sided Full Penetration Bevel

w GENuclearEnetgy 26A6473 SH NO. 131 REV. 0 OELD I

LOCATION I

CONFIGURATION l INSPECTION l ALLOWABLE N O.

J I__

J _

_W PS 720 Center Trough Bridge Extension Center Seam Weld (234C7320P001)

Alternate Configuration (Optional Use)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f Double Groove Full Penetration

w GENuclearEnergy 26A6473 SH NO. 132 l l REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWvABLE NO.

WPS 721 Center Trough Bridge VT, Root and 2.2.a, 2.2.b, Extension (On Final PT 2.2.c, 2.2.d, (234C7320P00 1/002) 2.2.e, 2.2.17 to Trough Bridge XCENTER TROUG4 BRODGE EXTENSION

't

/

l

/

ENTR E.FENER

_CENTER STIFFENER TO SUPPORT RIW CROSS MMBER (VL 724 £ 727)

CENTER STIFENER TO CENTER TROUGH BRIDGE EXTENSION WELO. TYPIAL (SINGLE I DOUBLE BEVEL)

WELD 722 A2M

wY GENuclearEneigy 26A6473 SHNO. 133 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE BRIDGE EXTENSIO TROUGH BRIDGE CSTING 1.00

.060 450 S FuElLD 721 BOTH SIDES

____SingleSidedFullPenetrationBevel

GENuclearEnerqy 26A6473 SH NO. 134 REV. 0 WELD LOCATION I

CONFIGURATION INSPECTION I ALLOWABLE NO.

I ws 722 Center Stiffener (234C7321P001)

(Double Bevel Plate) to Center Trough Bridge Extension (234C7320P00 1/002)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f DETAIL A Double Bevel Full Penetration

GENuclearEnergy 26A6473 SHNO. 135 1 l REV. 0 J

WELD LOCATION CONFIGURATION INSPECTION ALLOWVABLE NO.

_W PS 723 Center Stiffener VT, Root and 2.2.a, 2.2.b, (234C7321 P002)

Final PT 2.2.c, 2.2.d, (Single Bevel Plate)

ENTR TROUGH BRIDGE 2.2.e, 2.2.f to Center Trough ENSON Bridge Extension (234C7320P00 1/002) 45-.,

/

-ETRSlNER

\\/_

C(SINGLE BEVE PLTE)

.50 Single Bevel Full Penetration 724 Center Stiffener VT, Root and 2.2.a, 2.2.b, (234C7321P001)

Final PT 2.2.c, 2.2.d, (Double Bevel Plate) 2.2.e, 2.2.f to Support Ring Cross Member 3/8" Fillet Partial Penetration All Around

a GENuclearEDergy 26A6473 SHNO. 136 REV. 0 WELD I LOCATION l

CONFIGURATION INSPECTION I ALLOWABLE NO.

JI I

j WPS 727 Center Stiffener (234C7321 P002)

(Single Bevel Plate) to Support Ring Cross Member VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f 3/8" Fillet Partial Penetration All Around

GENuclearEneDry 26A6473 SHNO. 137 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

UWPS 729 Center Stiffener w

VT, Surface PT 2.2.a, 2.2.b, (234C7321P001)

Ym"BE 2.2.c, 2.2.d, (Double Bevel Plate) mPIACM 2.2.e, 2.2.f to Support Ring

\\ENER Cross Member Inside

\\

OULE BELATE)

Weld SUPPMR RM" MEMR OSE M

As Found Partial Penetration Flare Groove (Single Pass Min)

9, GENuclearEnergy 26A6473 SHNO. 138 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOW^ABLE NO.

wPS 730 Center Reinforcing VT, Root and 2.2.a, 2.2.b, Tee (234C7325P002) 06 ENTE RRINFORGPTE Final PT 2.2.c, 2.2.d, to Center Reinforcing 2.2.c, 2.2.f Plate (234C7325P003)

WELD

-ENTE REINFORCING TEE

.381 Double Groove Full Penetration 731 Lifting Rod Support VT, Root and 2.2.a, 2.2.b, Casting Modification Final PT 2.2.c, 2.2.d, Weld of Tie Beam 2.2.e, 2.2.f Notch Out Area Double Bevel Full Penetration

k0 GENuclearEnergy 26A6473 SHNO. 139 REV. 0 3.8 Modification Weld Conflaurations Table 8-Miscellaneous Weld Configurations Note: Unless otherwise specified. all bevel anp-le tolerances are +30°/-10° WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 1000 NOT USE 1010 Latch Box VT, Surface PT 2.2.a, 2.2.b, Modification Weld Fillet All around Partial Penetration 2.2.c, 2.2.d, 2.2.e, 2.2.f 1011 Trough bridge Sa S

VT, Root and 2.2.a, 2.2.b, extension Final PT 2.2.c, 2.2.d, (234C7323P001) to 2.2.e, 2.2.f Trough Bridge (Double Bevel Side)

IXTEW*N MATES SWR~ATE

GENuclearneirgy 26A6473 SHNO. 140 REV. 0 VELD LOCATION CONFIGURATION INSPECTION ALLOWABLE N O.

_W p s K

<WELD 1011 TROUGH BRIDGE EXTENSION

.060

.500 45:%.'15 I

DoubleBevelFullPenetration_

w GENuclear Eneiy 26A6473 SHNO. 141 REV. 0 LOCATION Bank to Bank Plate to Bank (Perf. Plate Seam) Weld Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f

w GENuclearEnergy 26A6473 SHNO. 142 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

IUPS WELD 1070 PLATE SEE WELD 101 DETAIL A

'GRIND FLUSH IF NEEDED Double Bevel Full Penetration Cover Fillets to edge of perforated plate only

w GENuclearEnerjy 26A6473 SH NO. 143 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 1071 Bank to Bank plate to 4

VT, Root and 2.2.a, 2.2.b, Dryer Hood Side Final PT 2.2.c, 2.2.d, Weld 2.2.e, 2.2.f' LA8 1-BANKTOBA PLATE MIDICENTER SINGLE PASS HOOD E

1071 SINGLE PASM Double Bevel Full Penetration With Single Pass Cover Fillet 1072 Center Transition Tee VT, Root and 2.2.a, 2.2.b, to Center Bank Inner Final PT 2.2.c, 2.2.d, Plenum Top Above 2.2.e, 2.2.f Perforated Plate h

/

2 (Center Reinforcing I

Plate)

ENTER RAWl CENTER REWORCING PtA Single Bevel Full Penetration Alternate Configuration Double Bevel Full Penetration with best effort cover fillet

GENuclearEn7eiry 26A6473 SHNO. 144 REV. 0 CONFIGURATION Bank to Bank Curve Extension to Bank Vane Cap Curve Weld Alternate Configuration (Optional Use)

VT, Root and Final PT 2.2.a, 2.2.b, 2.2.c, 2.2.d, 2.2.e, 2.2.f TIE BEAM

-BANK TO BANK CURVE EXTENSION BANK VANE BANK TO BAM SEAM WELD Double Bevel Full Penetration Through Curve Best Effort Cover Fillet

GENuclearneirgy 26A6473 SH NO. 145 REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

_WPS 1074 Bank to Bank Plate to Alternate Configuration (Optional Use)

VT, Root and 2.2.a, 2.2.b, Bank to Bank Curve Final PT 2.2.c, 2.2.d, Extension Weld

/A C TO 1loN 2.2.e, 2.2.f WELD 1074 BANK TO BANK P LATE

.38 Double Groove Full Penetration 1075 Center Transition Tee VT, Root and 2.2.a, 2.2.b, to Bank to Bank Plate ENTER TRANSmONTEE Final PT 2.2.c, 2.2.d, 2.2.e, 2.2.f WELD 1075 DK TO OK PLATE

]

1 l

Double Groove IFull Penetration

W GENuclearEnergy 26A6473 SH NO. 146 l REV. 0 WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

WPS 1076 Center Transition Tee EMERMNUMN VT, Root and 2.2.a, 2.2.b, to Mid/Outer Bank EFinal PT 2.2.c, 2.2.d, Inner Plenum Top 2.2.e, 2.2.f Above Perforated Plate (Bank to Bank Plate) 0_5.38 D BANK BANK TO BANK P Single Bevel Full Penetration Alternate Configuration Double Bevel Full Penetration if Accessible with best effort cover fillet

GENuclearEnergy 26A6473 SH NO. 147 REV. 0 FINAL WELD LOCATION CONFIGURATION INSPECTION ALLOWABLE NO.

_WPS 1077 Center Transition Tee

.05 VT, Root and 2.2.a, 2.2.b, to Center Reinforcing Final PT 2.2.c, 2.2.d, Plat ENTER TRANSITION TEE 22e Plate~~

,..e 2.2 WELD 1077 ENTER REINFORCING PLATE

.Don

~~Double Groove Full Penetration_______

/I

,1 l