Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility:
BVPS Unit 1 Task No.:
0481 -01 4-03-01 3 Task
Title:
Perform RCS Cooldown Verification JPM No.:
2005 NRC RO Admin No. 1 WA
Reference:
2.1.25 (2.8)
Examinee:
Facility Evaluator:
NRC Examiner:
Date:
Method of testinq Simulated Performance:
Actual Performance:
X Classroom X
Simulator Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
Task Standard:
Required Materials:
General
References:
Handouts:
Initiating Cue:
Time Critical Task:
Validation Time:
A plant shutdown to Mode 5 is in progress.
Current RCS wide range temperature and pressure are 238°F and 1,220 psig respectively.
Data Sheet 3: RCS Cooldown Determination is in effect to track RCS cooldown limits per 1 OM-52.4.NR.1.F, Non-Refueling Station Shutdown From 100% Power To Mode 5.
RCS cooldown rate calculated and temperature and pressure verified NOT to be within region of 1 OM-51.5, Figure 51 -2.
Calculator 1 OM-52.4.NR.l.F, Non-Refueling Station Shutdown From 100% Power To Mode 5, Rev. 6 Data Sheet 3: RCS Cooldown Determination (Modified with entries) 1 OM-52.4.NR.1.F, Attachment 13: RCS/PRZR COOLDOWN SURVEILLANCE Figure 51 -2, Beaver Valley Unit 1 Reactor Coolant System Cooldown Limitations The Unit Supervisor directs you to complete the information required for the 1100 hour0.0127 days <br />0.306 hours <br />0.00182 weeks <br />4.1855e-4 months <br /> entry of Data Sheet 3, RCS Cooldown Determination and verify the RCS cooldown is within acceptable limits using Attachment 13, RCS/PRZR Cooldown Surveillance. Report your results when finished.
No 9 minutes BVPS-1 NRC ADMIN NO. 1 NUREG 1021, Revision 9
Appendix C Page 2 of 5 Form ES-C-1 2005 NRC ADMIN NO. 1 PERFORMANCE INFORMATION (Denote Critical Steps with a check mark)
START TIME:
4 Performance Step: 1 Calculate the RCS cooldown rate at least once per 30 minutes during system cooldown using the following equation AND Record the results on Data Sheet 3:
COOLDOWN RATE = [TEMPf -TEMPI) X 60 MIN/HR Candidate correctly calculates current RCS cooldown rate as 5O0F/hr.
(Step 1)
CHANGE IN TIME Standard:
1238°F - 263°F) x 60 = - 50°F 30 Comment:
Performance Step: 2 Standard:
Verify the RCS cooldown rate is I 100 F/HR at least once per 30 minutes during system cooldown.
Candidate determines RCS cooldown rate is within the acceptable limit of less than or equal to 100°/hr.
(Step 1)
Comment:
BVPS-1 NRC ADMIN NO. 1 NUREG 1021, Revision 9
Appendix C Page 3 of 5 Form ES-C-1 2005 NRC ADMIN NO. 1 PERFORMANCE INFORMATION
.I Performance Step: 3 (Step 1)
Standard:
Standard:
Verify temperature VR-1 RC-4101 OR (T0406A, T0426A, T0446A) AND
[PR-1 RC-4031, RCS Pressure (P0499A) are WITHIN the Acceptable Operation region of 1 OM-51.5, Figure 51 -2, "Beaver Valley Unit 1 Reactor Coolant System Cooldown Limitations", at least once per 30 minutes during system cooldown AND Record the results on Data Sheet 3.
Candidate determines that current RCS temperature and pressure are NOT within the acceptable region of Figure 51 -2.
Candidate reports the results to the Unit Supervisor.
Comment:
Terminating Cue:
When the Candidate reports the results of the cooldown determination, the evaluation for this JPM is complete.
STOP TIME:
BVPS-1 NRC ADMIN NO. 1 NUREG 1021, Revision 9
Appendix C Page 4 of 5 Form ES-C-1 2005 NRC ADMlN NO. 1 VERIFICATION OF COMPLETION JPM No.:
2005 NRC RO No. 1 Examinees Name:
Examiners Name:
Date Performed:
Facility Evaluator:
Number of Attempts:
Time to Complete:
Question Documentation:
Question:
Response
Result: Satisfactory/Unsatisfactory Examiners Signature:
BVPS-1 NRC ADMIN NO. 1 Date:
NUREG 1021. Revision 9
Appendix C Page 5 of 5 Form ES-C-1 2005 NRC ADMIN NO. 1 JPM CUE SHEET IN IT1 AL CON DlTlO NS:
. A plant shutdown to Mode 5 is in progress.
Current RCS wide range temperature and pressure are 238°F and 1,220 psig respectively.
Data Sheet 3: RCS Cooldown Determination is in effect to track RCS cooldown limits per 1OM-52.4.NR.l.F, Non-Refueling Station Shutdown From 100% Power To Mode 5.
INITIATING CUE:
BVPS-1 NRC ADMIN NO. 1 The Unit Supervisor directs you to complete the information required for the 1100 hour0.0127 days <br />0.306 hours <br />0.00182 weeks <br />4.1855e-4 months <br /> entry of Data Sheet 3, RCS Cooldown Determination and verify the RCS cooldown is within acceptable limits using Attachment 13, RCS/PRZR Cooldown Surveillance. Report your results when finished.
NUREG 1021, Revision 9
Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility:
BVPS Unit 1 Task No.:
001 1-003-01 -01 3 Task
Title:
Perform an Estimated Critical Position JPM No,:
2005 NRC RO Calculation Admin No. 2 WA
Reference:
2.1.23 (3.9)
Examinee:
NRC Examiner:
Facility Evaluator:
Date:
Method of testinu:
Simulated Performance:
Actual Performance:
X Classroom X
Simulator Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
Task Standard:
Required Materials:
General
References:
Handouts:
Initiating Cue:
Time Critical Task:
Validation Time:
Boron concentration for startup calculated within the specified tolerance.
Calculator; ECP Answer Sheet 1 OM-50.4.F, Performing An Estimated Critical Position Calculation, Rev. 3 BV-1 Curve Book 10M-50.4.F, with Critical Data recorded in DATA SHEET 1 BV-1 Cycle 17 Curves The Shift Manager directs you to determine the boron concentration for startup using 1 OM-50.4.F, Performing An Estimated Critical Position Calculation. The Critical Data has been entered on Data Sheet 1.
No 35 minutes A plant startup is being performed 5 days after a reactor trip from 100% power.
Core burnup is 8,000 MWD/MTU.
RCS boron concentration is 871 ppm.
The plant computer is NOT available.
B-10 Correction Factor is available from the Curve Book.
BVPS-1 NRC ADMlN NO. 2 NUREG 1021, Revision 9
Appendix C Page 2 of 6 Form ES-C-1 2005 NRC ADMlN NO. 2 PERFORMANCE INFORMATION (Denote Critical Steps with a check mark)
START TIME:
Performance Step: 1 (Data Sheet 1)
Standard:
(Part A.III)
(Part A N )
(Part A.V)
Calculate Effective Boron Concentration Candidate correctly calculates Part A, Item V.
Boron concentration = 871 ppm (Initial Conditions) 6-1 0 Correction Factor = 0.91 9 (CB-29)
Effective Boron Concentration = 800 ppm Comment:
Performance Step: 2 (Data Sheet 1 )
Standard:
(Part B.l)
(Part B.2)
(Part B.3)
(Part B.4)
(Part B.5)
Calculate Reactivity Change Candidate correctly calculates Part B, Item 5.
Power Defect = - 2100 pcm (CB-21)
Control Rods = + 775 pcm (CB-24B)
Xenon = - 2713 pcm ((26-23)
Samarium = + 238 pcm (CB-22)
Reactivity Change = - 3800 pcm Comment:
BVPS-1 NRC ADMlN NO. 2 NUREG 1021, Revision 9
Appendix C Page 3 of 6 Form ES-C-1 2005 NRC ADMIN NO. 2 PERFORMANCE INFORMATION Performance Step: 3 (Data Sheet 1)
Standard:
(Part C.1)
(Part CAI)
(Part C.III)
(Part C.IV)
(Part C.V)
Calculate Effective Boron Concentration for Startup Candidate correctly calculates Part C, Line 1, Item V.
Reactivity Change = - 3800 pcm (B.5)
Differential Boron Worth = - 7.81 pcrdppm (CB-20)
Boron Change = + 487 ppm Eff. Boron Conc. at Shutdown = 800 ppm (from Part A.V)
Eff. Boron Conc. For Startup = 1287 ppm Comment:
Performance Step: 4 (Data Sheet 1)
Standard:
(Part C.1)
(Part CAI)
(Part C.III)
(Part C.IV)
(Part C.V)
Calculate Effective Boron Concentration for Startup Candidate correctly calculates Part C, Line 2, Item V Reactivity Change = - 3800 pcm (from 8.5)
Differential Boron Worth = - 7.46 pcdppm (CB-20)
Boron Change = + 509 ppm Eff. Boron Conc. at Shutdown = 800 ppm Eff. Boron Conc. For Startup = 1309 ppm Com men t :
BVPS-1 NRC ADMIN NO. 2 NUREG 1021, Revision 9
Appendix C Page 4 of 6 Form ES-C-1 2005 NRC ADMIN NO. 2 PERFORMANCE INFORMATION 4
Performance Step: 5 Calculate Boron Concentration for Startup (Data Sheet 1 )
Standard:
(Part C.VI)
(Part C.Vll)
(Part C.VlII)
Candidate correctly calculates Part C, Item VIII.
Eff. Boron Conc. For Startup = - 1309 pcm B-10 Correction Factor = 0.91 9 (CB-29)
Boron Concentration for Startup = 1424 ppm (1372 - 1472)
Comment:
I Terminating Cue:
When the Candidate completes the calculation, the evaluation for this I
JPM is complete.
STOP TIME:
BVPS-1 NRC ADMIN NO. 2 NUREG 1021, Revision 9
Appendix C Page 5 of 6 Form ES-C-1 VERIFICATION OF COMPLETION 2005 NRC ADMIN NO. 2 JPM No.:
2005 NRC RO No. 2 Examinees Name:
Examiners Name:
Date Performed:
Facility Evaluator:
Number of Attempts:
Time to Complete:
Question Documentation:
Question:
Response
~~~
Result: Satisfactory/Unsatisfactory Examiners Signature:
Date:
BVPS-1 NRC ADMIN NO. 2 NUREG 1021, Revision 9
Appendix C Page 6 of 6 Form ES-C-1 2005 NRC ADMIN NO. 2 JPM CUE SHEET IN IT1 AL CON DIT1 ON S:
A plant startup is being performed 5 days after a reactor trip from 100% power.
Core burnup is 8,000 MWD/MTU.
RCS boron concentration is 871 ppm.
The plant computer is NOT available.
6-1 0 Correction Factor is available from the Curve Book.
INITIATING CUE:
The Shift Manager directs you to determine the boron concentration for startup using 1 OM-50.4.F, Performing An Estimated Critical Position Calculation. The Critical Data has been entered on Data Sheet 1.
BVPS-1 NRC ADMIN NO. 2 NUREG 1021, Revision 9
Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility:
BVPS Unit 1 Task No.: 0481 -020-03-013 Task
Title:
Review a Taqqinq Request JPM No.:
2005 NRC RO Admin No. 3 WA
Reference:
2.2.13 (3.6)
Examinee:
NRC Examiner:
Facility Evaluator:
Date:
Method of testina:
Simulated Performance:
Actual Performance:
X Classroom X
Simulator Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
Task Standard:
Required Materials:
General
References:
Handouts:
Initiating Cue:
Time Critical Task:
Validation Time:
The plant is operating at 100% power with all systems in their normal operating alignment. A tagout section has been prepared to isolate and drain [l QS-P-2B1, RWST Recirculating Pump for maintenance.
Correctly review a clearance tagout section and identify errors.
None NOP-OP-1001, Clearancenagging Program, Rev. 4 Tagging Section with errors 1OM-13.3.8.1, Valve List - lQS, Rev. 12 1 OM-l3.3.C, Power Supply And Control Switch List, Issue 4, Rev. 4, OP Manual Fig. No. 13-1, Containment Depressurization System, Rev. 18 NOP-OP-1001, Clearanceflagging Program, Rev. 4 The Unit Supervisor directs you to conduct a review of the attached tagout section that is being prepared for use and determine its completeness and accuracy. Report your results when finished.
Yes 10 minutes BVPS-1 NRC ADMIN NO. 3 NUREG 1021, Revision 9
Appendix C Page 2 of 4 Form ES-C-1 2005 NRC ADMIN NO. 3 PERFORMANCE INFORMATION (Denote Critical Steps with a check mark)
START TIME:
NOTE:
This task is normally performed using the eSOMS clearance computer and signed electronically. If necessary, for the purpose of this JPM, inform the Candidate to review a hardcopy of the tagout for approval in place of performing an electronic review.
4 Performance Step: 1 Review the tagout section for accuracy and completeness.
Standard:
Candidate verifies tagout section is appropriate for the task.
Standard:
Candidate identifies and reports the following tagout errors:
Valve 1 QS-20 is not the correct discharge isolation point.
(1 QS-P-2A vs. 28). The correct valve is 1 QS-21.
Valve QS-16 is not a correct suction isolation point.
(1 QS-P-2A vs. 28). The correct valve is 1 QS-17.
CUE:
If the Candidate asks for direction following identification of the first error, direct the Candidate to review the remainder of the tagout section.
NOTE:
If questioned by the Candidate, confirm that valve 1QS-83-3 is not shown on the attached print; however, it is an appropriate drain point.
Comment:
Terminating Cue:
When the Candidate reports the results of the review, the evaluation for this JPM is complete.
STOP TIME:
BVPS-1 NRC ADMIN NO. 3 NUREG 1021, Revision 9
Appendix C Page 3 of 4 Form ES-C-1 VERIFICATION OF COMPLETION 2005 NRC ADMIN NO. 3 JPM No.:
2005 NRC RO No. 3 Examinees Name:
Examiners Name:
Date Performed:
Facility Evaluator:
Number of Attempts:
Time to Complete:
Question Documentation:
Question:
Response
Result: Satisf actory/U nsatisf actory Examiners Signature:
Date:
BVPS-1 NRC ADMIN NO. 3 NUREG 1021, Revision 9
Appendix C Page 4 of 4 Form ES-C-1 2005 NRC ADMIN NO. 3 JPM CUE SHEET INITIAL CONDITIONS:
The plant is operating at 100% power with all systems in their normal operating alignment. A tagout section has been prepared to isolate and drain [lQS-P-2B], RWST Recirculating Pump for maintenance.
INITIATING CUE:
BVPS-1 NRC ADMIN NO. 3 The Unit Supervisor directs you to conduct a review of the attached tagout section that is being prepared for use and determine its completeness and accuracy. Report your results when finished.
NUREG 1021, Revision 9
Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility:
BVPS Unit 1 Task No.:
Task
Title:
Select RWP and Determine Maximum JPM No.:
2005 NRC RO Allowable Stay Time Admin No. 4 WA
Reference:
2.3.2 (2.5)
Examinee:
NRC Examiner:
Facility Evaluator:
Date:
Method of testinq:
Simulated Performance:
Actual Performance:
X Classroom X
Simulator Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
Both Units are operating at 100% power. A void has developed in the suction line to [l CH-P-1 B], Charging Pump. You are NOT currently signed on to fill any operator positions. Your current TEDE dose for the quarter is 150 mR.
Task Standard:
Select the correct RWP and determine the maximum stay time according to the survey map dose rates.
Required Materials:
None General
References:
1 /2-ADM-1630, Radiation Worker Practices, Rev. 8 Handouts:
Set of 3 RWPs Radiation Survey Map Initiating Cue:
You are to assist a QC Inspector in performing an ultrasonic examination of the void. You are directed to SELECT the correct RWP to perform this task, and calculate your MAXIMUM stay time in the charging pump room based on the radiation readings from a survey map. Report your results when finished.
Time Critical Task:
NO Validation Time:
11 minutes BVPS-1 NRC ADMIN NO. 4 NUREG 1021, Revision 9
Appendix C Page 2 of 4 Form ES-C-1 2005 NRC ADMIN NO. 4 PERFORMANCE INFORMATION (Denote Critical Steps with a check mark)
START TIME:
I NOTE:
Provide the Candidate with the set of RWPs and Survev MaD.
4 Performance Step: 1 Select the correct RWP.
Standard:
Candidate correctly selects RWP 205 - 1003 based on < 100 mWhr General Area Range and EAD dose alarm setpoint of 100 mR.
NOTE:
If asked, inform the Candidate that it is permissible to perform the work on a non-Operations RWP.
Comment:
4 Performance Step: 2 Calculate the maximum stay time.
Standard:
Comment:
Candidate correctly calculates maximum stay time as 2 hrs.
2 hrs.
100 mR 50 mWhr.
(EAD dose limit)
(highest dose rate)
(Stay time)
Terminating Cue:
When the Candidate reports the results, the evaluation for this JPM is complete.
STOP TIME:
BVPS-1 NRC ADMIN NO. 4 NUREG 1021, Revision 9
Appendix C Page 3 of 4 Form ES-C-1 2005 NRC ADMIN NO. 4 VERIFICATION OF COMPLETION JPM No.:
2005 NRC RO No. 4 Examinees Name:
Examiners Name:
Date Performed:
Facility Evaluator:
Number of Attempts:
Time to Complete:
Question Documentation:
Question:
Response
Result: Satisfactory/Unsatisfactory Examiners Signature:
BVPS-1 NRC ADMIN NO. 4 Date:
NUREG 1021, Revision 9
Appendix C Page 4 of 4 Form ES-C-1 2005 NRC ADMIN NO. 4 JPM CUE SHEET INITIAL CONDITIONS:
Both Units are operating at 100% power. A void has developed in the suction line to [ l CH-P-1 B], Charging Pump. You are NOT currently signed on to fill any operator positions. Your current TEDE dose for the quarter is 150 mR.
INITIATING CUE:
BVPS-1 NRC ADMIN NO. 4 You are to assist a QC Inspector in performing an ultrasonic examination of the void. You are directed to SELECT the correct RWP to perform this task, and calculate your MAXIMUM stay time in the charging pump room based on the radiation readings from a survey map. Report your results when finished.
NUREG 1021, Revision 9
Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility:
BVPS Unit 1 Task No.:
1320-008-03-023 Task
Title:
Determine Action Required For Failed AC JPM No.:
2005 NRC SRO Sources Surveillance Admin No. 1 WA
Reference:
2.1.1 2 (4.0)
Examinee:
NRC Examiner:
Facility Evaluator:
Date:
Method of testinu:
Simulated Performance:
Actual Performance:
X Classroom X
Simulator Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
The plant is operating at 100% power with all systems in their normal operating alignment. The No. 1 EDG was declared inoperable and removed from service 30 minutes ago due to a ruptured engine cylinder. The PO has completed 1 OST-36.7, Offsite to Onsite Power Distribution System Breaker Alignment Verification.
Task Standard:
Procedure errors are identified and Technical Specification action requirements are determined for a failed surveillance test.
Required Materials:
None General
References:
1 OST-36.7, Offsite To Onsite Power Distribution System Breaker Alignment Verification, Rev. 8 BVPS Unit 1 Technical Specifications LCO 3.8.1.1 Handouts:
1 OST-36.7, Offsite To Onsite Power Distribution System Breaker Alignment Verification, Rev. 8 (marked up copy)
BVPS Unit 1 Technical Specifications LCO 3.8.1.1 Initiating Cue:
The Shift Manager directs you to review the completed 1 OST-36.7, Offsite To Onsite Power Distribution System Breaker Alignment Verification for completeness. Report your results when finished.
Time Critical Task:
No Validation Time:
10 minutes BVPS-1 NRC ADMIN NO. 1 NUREG 1021, Revision 9
Appendix C Page 2 of 5 Form ES-C-1 2005 NRC ADMIN NO. 1 PERFORMANCE INFORMATION (Denote Critical Steps with a check mark)
START TIME:
I/
Performance Step: 1 Review the Initial Conditions section for completeness.
Standard:
Candidate determines that signoffs are missing for the following steps:
111.1.b (power via USST's or SSST's) 111.3 (operators have reviewed procedure)
Comment:
I/
Performance Step: 2 Review Data Sheet 1 for completeness.
Standard:
Candidate determines that the white light for 4KV breaker ACB-341 B is marked as OFF.
NOTE:
This lineup is required to satisfy the requirement for physically independent offsite circuits indicated by the white light being ON.
Comment:
BVPS-1 NRC ADMIN NO. 1 NUREG 1021, Revision 9
Appendix C Page 3 of 5 Form ES-C-1 2005 NRC ADMIN NO. 1 PERFORMANCE INFORMATION 4
Performance Step: 3 Determine Technical Specification Action Statement requirements.
Candidate determines that OST does not satisfy the Acceptance Criteria.
Standard:
Standard:
Candidate identifies applicability of T.S. Action Statement 3.8.1.1.c with one offsite circuit and one diesel generator inoperable.
NOTE:
Provide the Candidate with a copy of the T.S.
handout.
NOTE:
Refer to attached Technical Specification LCO 3.8.1.1 Action c for applicable requirements for an inoperable offsite circuit and diesel generator.
Comment:
Terminating Cue:
When the Candidate identifies the Technical Specification action statement requirement, the evaluation for this JPM is complete.
STOP TIME:
BVPS-1 NRC ADMIN NO. 1 NUREG 1021, Revision 9
Appendix C Page 4 of 5 Form ES-C-1 2005 NRC ADMIN NO. 1 VERIFICATION OF COMPLETION JPM No.:
2005 NRC SRO No. 1 Examinees Name:
Examiners Name:
Date Performed:
Facility Evaluator:
Number of Attempts:
Time to Complete:
Question Documentation:
Response
Result: Satisfactory/Unsatisfactory Examiners Signature:
BVPS-1 NRC ADMIN NO. 1 Date:
NUREG 1021, Revision 9
Appendix C Page 5 of 5 Form ES-C-1 2005 NRC ADMIN NO. 1 JPM CUE SHEET INITIAL CONDITIONS:
The plant is operating at 100% power with all systems in their normal operating alignment. The No. 1 EDG was declared inoperable and removed from service 30 minutes ago due to a ruptured engine cylinder. The PO has completed 1 OST-36.7, Off site to Onsite Power Distribution System Breaker Alignment Verification.
INITIATING CUE:
BVPS-1 NRC ADMIN NO. 1 The Shift Manager directs you to review the completed 1 OST-36.7, Offsite To Onsite Power Distribution System Breaker Alignment Verification for completeness. Report your results when finished.
NUREG 1021, Revision 9
Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility:
BVPS Unit 1 Task No.: 001 1-003-01 -01 3 Task
Title:
Review an Estimated Critical Position JPM No.:
2005 NRC SRO Calculation Admin No. 2 WA
Reference:
2.1.23 (4.0)
Examinee:
Facility Evaluator:
NRC Examiner:
Date:
Method of testina:
Simulated Performance:
Actual Performance:
X Classroom X
Simulator Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
A plant startup is being performed 5 days after a reactor trip from 100% power.
9 Core burnup is 8,000 MWD/MTU.
=
RCS boron concentration is 871 ppm.
. The plant computer is NOT available.
. B-10 Correction Factor is available from the CB Curves.
Task Standard:
Boron concentration for startup value is calculated within the specified tolerance.
Required Materials:
Calculator; ECP Answer Sheet General
References:
1 OM-50.4.F, Performing An Estimated Critical Position Calculation, Rev. 3 BV-1 Curve Book Handouts:
1 OM-50.4.F, (with completed DATA SHEET 1)
BV-1 Cycle 17 Curves Initiating Cue:
The Shift Manager directs you to perform a review of a completed ECP calculation in accordance with 1 OM-50.4.F, Performing An Estimated Critical Position Calculation. Report your results when finished.
Time Critical Task:
No Validation Time:
15 minutes BVPS-1 NRC ADMIN NO. 2 NUREG 1021, Revision 9
Appendix C Page 2 of 5 Form ES-C-1 2005 NRC ADMIN NO. 2 PERFORMANCE INFORMATION (Denote Critical Steps with a check mark)
START TIME:
Performance Step: 1 (Data Sheet 1)
Standard:
(Step IV.I.l.b)
(Part 8.2)
(Part 8.2)
(Part B.5)
(Part C.1, Line 1)
(Part C.III, Line 1)
(Part C.V, Line 1)
(Part C.111, Line 2)
(Part C.V, Line 2)
(Part C.VI)
(Part C.VII)
Review the ECP calculation.
Candidate identifies the following errors:
Performed By signature is missing.
CB-24A is incorrectly circled. Correct figure is CB-246.
Control Rod reactivity values are incorrect in Columns II and Ill.
The correct number is 775.
Reactivity Change value is incorrect. The correct number is 3800.
Reactivity Change value is incorrect (carryover from previous step).
Boron Change value is incorrect. The correct number is 487.
Eff. Boron Conc. For Startup value is incorrect. The correct number is 1287.
Boron Change value is incorrect. The correct number is 509.
Eff. Boron Conc. For Startup value is incorrect. The correct number is 1309.
Eff. Boron Conc. For Startup value is incorrect (carryover from previous step).
B-10 Correction Factor for Criticality value is incorrect. The correct number is 0.91 9.
BVPS-1 NRC ADMlN NO. 2 Comment:
NUREG 1021, Revision 9
Appendix C Page 3 of 5 Form ES-C-1 2005 NRC ADMIN NO. 2 PERFORMANCE INFORMATION Performance Step: 2 (Data Sheet 1)
Standard:
(Part C.VlII)
Review the ECP calculation.
Candidate correctly determines the boron concentration required for startup.
Boron Concentration for Startup value is incorrect. The correct number is 1424. (Accept value between 1372 - 1472).
Comment:
Terminating Cue:
When the Candidate completes the review of the calculation and reports the results, the evaluation for this JPM is complete.
BVPS-1 NRC ADMIN NO. 2 NUREG 1021, Revision 9
Appendix C Page 4 of 5 Form ES-C-1 2005 NRC ADMIN NO. 2 VERIFICATION OF COMPLETION JPM No.:
2005 NRC SRO No. 2 Examinees Name:
Examiners Name:
Date Performed:
Facility Evaluator:
Number of Attempts:
Time to Complete:
Question Documentation:
Question:
Response
Result: Satisfactory/Unsatisfactory Examiners Signature:
Date:
BVPS-1 NRC ADMIN NO. 2 NUREG 1021 I Revision 9
Appendix C Page 5 of 5 Form ES-C-1 2005 NRC ADMIN NO. 2 JPM CUE SHEET INITIAL CONDITIONS:.
A plant startup is being performed 5 days after a reactor trip from 100% power.
Core burnup is 8,000 MWD/MTU.
RCS boron concentration is 871 ppm.
The plant computer is NOT available.
B-10 Correction Factor is available from the CB Curves.
INITIATING CUE:
The Shift Manager directs you to perform a review of a completed ECP calculation in accordance with 1 OM-50.4.F, Performing An Estimated Critical Position Calculation. Report your results when finished.
BVPS-1 NRC ADMIN NO. 2 NUREG 1021, Revision 9
Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility :
BVPS Unit 1 Task No.:
1300-023-03-023 Task
Title:
Approve a Taqaintl Reauest JPM No.:
2005 NRC SRO Admin No. 3 WA
Reference:
2.2.13 (3.8)
Examinee:
NRC Examiner:
Facility Evaluator:
Date:
Method of testina:
Simulated Performance:
Actual Performance:
X Classroom X
Simulator Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
The plant is operating at 100% power with all systems in their normal operating alignment. A tagout section has been prepared to isolate and drain [l QS-P-261; RWST Recirculating Pump for maintenance.
Task Standard:
Review a clearance tagout section and identify errors.
Required Materials:
None General
References:
NOP-OP-1001, Clearancenagging Program, Rev. 4 Handouts:
Modified Tagging Request 1 OM-13.3.6.1, Valve List - 1 QS, Rev. 12 1 OM-l3.3.C, Power Supply And Control Switch List, Issue 4, Rev. 4, OP Manual Fig. No. 13-1, Containment Depressurization System, Rev. 18 NOP-OP-1001, Clearancenagging Program, Rev. 4 Initiating Cue:
The Shift Manager directs you to conduct a review of the attached tagout section that is ready for approval for completeness and accuracy. Report your results when finished.
Time Critical Task:
Yes Validation Time:
10 minutes BVPS-1 NRC ADMIN NO. 3 NUREG 1021, Revision 9
Appendix C Page 2 of 4 Form ES-C-1 2005 NRC ADMIN NO. 3 PERFORMANCE INFORMATION (Denote Critical Steps with a check mark)
START TIME:
1 NOTE:
This task is normally performed using the eSOMS clearance computer and signed electronically. If necessary, for the purpose of this JPM, inform the Candidate to review a hardcopy of the tagout for approval in place of performing an electronic review.
.( Performance Step: 1 Review the tagout section for accuracy and completeness.
Standard:
Candidate verifies tagout section is appropriate for the task.
Standard:
Candidate identifies and reports the following tagout errors:
' Breaker MCC1-19-G is tagged in the On position. The correct position is Off.
9 Valve 1QS-20 is not a correct discharge isolation point (1 QS-PQA vs. 26). The correct valve is 1 QS-21.
Valve 1 QS-16 is not a correct discharge isolation point (1 QS-P-2A vs. 2B). The correct valve is 1 QS-17.
CUE:
If the Candidate asks for direction following identification of the first error, direct the Candidate to review the remainder of the tagout section.
NOTE:
If questioned by the Candidate, confirm that valve 1QS-83-3 is not shown on the attached print; however, it is an appropriate drain point.
Comment:
Terminating Cue:
When the Candidate reports the results of the review, the evaluation for this JPM is complete.
STOP TIME:
BVPS-1 NRC ADMIN NO. 3 NUREG 1021, Revision 9
Appendix C Page 3 of 4 Form ES-C-1 2005 NRC ADMIN NO. 3 VERIFICATION OF COMPLETION JPM No.:
2005 NRC SRO No. 3 Examinees Name:
Examiners Name:
Date Performed:
Facility Evaluator:
Number of Attempts:
Time to Complete:
Question Documentation:
Question:
Response
Result: SatisfactoryAJnsatisfactory Examiners Signature:
BVPS-1 NRC ADMIN NO. 3 Date:
NUREG 1021, Revision 9
Appendix C Page 4 of 4 Form ES-C-1 2005 NRC ADMIN NO. 3 JPM CUE SHEET INITIAL CONDITIONS:
The plant is operating at 100% power with all systems in their normal operating alignment. A tagout section has been prepared to isolate and drain [1QS-P-26], RWST Recirculating Pump for maintenance.
INITIATING CUE:
BVPS-1 NRC ADMIN NO. 3 The Shift Manager directs you to conduct a review of the attached tagout section that is ready for approval for completeness and accuracy. Report your results when finished.
NUREG 1021, Revision 9
Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility:
BVPS Unit 1 Task No.: 1300-009-03-023 Task
Title:
Review a Gaseous Waste Discharae JPM No.: 2005 NRC SRO Authorization Admin No. 4 WA
Reference:
2.3.8 (3.2)
Examinee:
NRC Examiner:
Facility Evaluator:
Date:
Method of testing:
Simulated Performance:
Actual Performance:
X Classroom X
Simulator Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
Task Standard:
Required Materials:
General
References:
Handouts:
Initiating Cue:
Time Critical Task:
Validation Time:
The plant is in Mode 1 at 100% power. [lGW-TK-1 A], Gas Decay Tank is in the process of being released via an RWDA-G. The discharge started two hours ago and is expected to continue for another 28 hours3.240741e-4 days <br />0.00778 hours <br />4.62963e-5 weeks <br />1.0654e-5 months <br />.
Identify the error contained in a partially completed RWDA-G and correctly calculate a 2-hour bleed flow rate in accordance with 1 OM-19.4.E.
Calculator 1 OM-l9.4.E, Decay Tank Discharge, Rev. 6 1 OM-l9.4.E, Decay Tank Discharge, Rev. 6 (partially completed) 1/2-HPP-3.006.F01, Gaseous Radioactive Waste Discharge Authorization (Partially Completed) 1 GW-TK-1 A Parameters Table As the Unit Supervisor, you are to perform a review of the attached RWDA-G to verify that the information entered is correct, and calculate a 2-hour bleed flow rate in accordance with 1OM-l9.4.EI Decay Tank Discharge, Step IV.A.17. Report your results when finished.
No 12 minutes BVPS-1 NRC ADMIN NO. 4 NUREG 1021, Revision 9
Appendix C Page 2 of 6 Form ES-C-1 2005 NRC ADMlN NO. 4 PERFORMANCE INFORMATION (Denote Critical Steps with a check mark)
START TIME:
Performance Step: 1 Standard:
Candidate reviews the procedure for completeness.
Candidate reviews the procedure verifying that the procedure is signed up to Step IV.A.17.
NOTE:
This step may be performed at any time during the JPM.
Comment:
.I Performance Step: 2 Standard:
Standard:
(Step IV.A.6 Note)
Candidate reviews the RWDA-G.
Candidate reviews the partially completed RWDA-G for required data entry and completeness.
Candidate determines the Discharge Start date exceeds the 72-hour limit and requests a confirmatory sample to extend the authorization.
CUE:
Inform the Candidate that Chemistry will obtain a confirmatory sample and to continue with the JPM.
Comment:
Performance Step: 3 Candidate obtains required data for 2-hour bleed flow rate.
Standard:
Comment:
BVPS-1 NRC ADMlN NO. 4 Candidate reviews the Data Sheet to obtain the current decay tank pressure and time.
NUREG 1021, Revision 9
Appendix C Page 3 of 6 Form ES-C-1 PERFORMANCE I N FOR MATI ON 2005 NRC ADMIN NO. 4 4 Performance Step: 4 Calculate 2-hour bleed flow rate.
(Step IV.A.17.a)
Standard:
Candidate determines the discharge flow rate = 1.53 scfm as follows:
= 1.53 (132 CU. fr.) (55.0 PSZG - 34.5 PSZG)
Bleed Flow Rate =
(14.7 psi) (120 min. - 0 min.)
Comment:
4 Performance Step: 5 Verify bleed flow rate is within limits.
Standard:
Candidate verifies the calculated value is less than the RWDA-G limit of 2 scfm.
NOTE:
The JPM may be stopped at this point.
Comment:
Terminating Cue:
When the Candidate verifies the bleed flow rate is within limits, the evaluation for this JPM is complete.
STOP TIME:
BVPS-1 NRC ADMIN NO. 4 NUREG 1021, Revision 9
Appendix C Page 4 of 6 Form ES-C-1 2005 NRC ADMIN NO. 4 VERIFICATION OF COMPLETION JPM No.:
Examinees Name:
Examiners Name:
Date Performed:
Facility Evaluator:
Number of Attempts:
Time to Complete:
Question Documentation:
2005 NRC SRO No. 4
Response
Result: Satisfactory/Unsatisfactory Examiners Signature:
BVPS-1 NRC ADMIN NO. 4 Date:
NUREG 1021, Revision 9
Appendix C Page 5 of 6 Form ES-C-1 2005 NRC ADMIN NO. 4 JPM CUE SHEET INITIAL CONDITIONS:
The plant is in Mode 1 at 100% power. [ l GW-TK-1 A], Gas Decay Tank is in the process of being released via an RWDA-G. The discharge started two hours ago and is expected to continue for another 28 hours3.240741e-4 days <br />0.00778 hours <br />4.62963e-5 weeks <br />1.0654e-5 months <br />.
INITIATING CUE:
BVPS-1 NRC ADMIN NO. 4 As the Unit Supervisor, you are to perform a review of the attached RWDA-G to verify that the information entered is correct, and calculate a 2-hour bleed flow rate in accordance with 1 OM-l9.4.E, Decay Tank Discharge, Step IV.A.17. Report your results when finished.
NUREG 1021, Revision 9
Appendix C Page 6 of 6 Form ES-C-1 2005 NRC ADMIN NO. 4 JPM CUE SHEET 60 120 1 GW-TK-1 A Parameters Table
~~
~
~
44.8 psig 34.5 psig 1GW-TK-1A PRESSURE I
(PR-1GW-103)
I 0
I 55.0 psig I
BVPS-1 NRC ADMIN NO. 4 NUREG 1021, Revision 9
Appendix C Job Performance Measure Form ES-C-1 Worksheet Facility:
BVPS Unit 1 Task No.:
1350-004-03-023 1350-007-03-023 Task
Title:
Classifv an Event and Determine JPM No.:
2005 NRC SRO WA
Reference:
2.4.40 (4.0)
Protective Action Recommendations Admin No. 5 Examinee:
NRC Examiner:
Facility Evaluator:
Date:
Method of testing:
Simulated Performance:
Actual Performance:
X Classroom X
Simulator Plant READ TO THE EXAMINEE I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues.
When you complete the task successfully, the objective for this Job Performance Measure will be satisfied.
Initial Conditions:
Task Standard:
Required Materials:
General
References:
Handouts:
Initiating Cue:
Time Critical Task:
Validation Time:
Refer to INITIAL CONDITIONS pages for emergency classification and Protective Action Recommendations.
Correctly classify an emergency event using EPP/I-1 a and determine Protective Action Recommendations in accordance with 1/2-EPP-IP-4.1.
NONE EPP/I-1 a, Recognition And Classification of Emergency Conditions, Rev. 5 1/2-EPP-IP-4.1, Offsite Protective Actions, Rev. 18 EPP/I-1 a, Recognition And Classification of Emergency Conditions, Rev. 5 1/2-EPP-IP-4.11 Offsite Protective Actions, Rev. 18 As the Emergency Director, you are to evaluate the given plant conditions and determine the emergency classification in accordance with EPP/l-1 a, Recognition And Classification of Emergency Conditions. Report your results when finished.
YES - (15 minutes for Classification & 15 minutes for PAR) 16 minutes BVPS-1 NRC ADMIN NO. 5 NUREG 1021, Revision 9
Appendix C Page 2 of 7 Form ES-C-1 2002 Audit A4 SRO PERFORMANCE INFORMATION NOTE:
Provide the Candidate with the first set of Initial Conditions and a copy of EPP/I-l a, Recognition and Classification of Emergency Conditions.
(Denote Critical Steps with a check mark)
START TIME:
.I Performance Step: 1 Correctly classify the emergency event Standard:
Candidate classifies the event based on Tab 3.1, Loss of AC (Power Ops) as a General Emergency using the following criteria:
AE and DF 4KV emergency buses NOT energized from Unit 1 sources for > 15 minutes, and Five hottest CETs > 719F with no RCPs running and RVLIS full range < 40%
CUE:
Inform the Candidate that the Initial Notification Form will NOT be completed at this time.
NOTE:
Time Critical - The Candidate has 15 minutes to complete the emergency classification.
NOTE:
If the Candidate does NOT correctly classify the event, then stop the JPM at this point.
NOTE:
This JPM is conducted in two (2) parts. Once the Candidate determines the correct emergency classification, then administer the PAR section of the JPM.
Comment:
NOTE:
Provide the Candidate with the second set of Initial Conditions and a copy of 1/2-EPP-IP-4.1, Offsite Protective Actions.
BVPS-1 NRC ADMIN NO. 5 NUREG 1021, Revision 9
Appendix C Page 3 of 7 Form ES-C-1 2002 Audit A4 SRO PERFORMANCE INFORMATION Performance Step: 2 Locate Offsite Protective Action Recommendation Flowchart Standard:
Candidate refers to 1/2-EPP-IP-4.1, Attachment A, Offsite Protective Action Recommendation Flowchart.
Comment:
Performance Step: 3 Standard:
Determine offsite protective action Candidate navigates PAR flow chart as follows:
. General Emergency already declared (4)
Met data provided in Initial Conditions (4)
. None of the following are TRUE (J):
> 35 wind speed LESS than 2 MPH (or unavailable)?
> Is either 150 or 500 wind directions unavailable?
> The difference between the 150 & 500 wind directions is 2 165 and I 195 degrees? (opposite wind directions) or unavailable?
> Release (other than a non-routine minor release below Federally approved operating limits or wholly comprised of tritium) has started or is imminent. (within one hour)
> Release transport will span sunrise or sunset hours.
. Dose projection results available (FSAR, monitor data, etc.)?
-YES (+).
. Projected dose at EAB > 1 REM TEDE or > 5 REM CDE -
. TEDE is less than 10 REM at EAB - NO (4)
. Projected dose at 5 miles: > 1 REM TEDE or > 5 REM CDE -
. Projected dose at 2 miles: > 1 REM TEDE or > 5 REM CDE -
YES (+)
NO (-1)
YES (-+)
Comment:
BVPS-1 NRC ADMIN NO. 5 NUREG 1021, Revision 9
Appendix C Page 4 of 7 Form ES-C-1 2002 Audit A4 SRO PERFORMANCE INFORMATION
.( Performance Step: 4 Determine Off site Protective Action Recommendations Standard:
Candidate determines the following PARS:
. Evacuate 2 miles, 360 degrees, and
. Evacuate 5 mile downwind wedge, and Shelter the remainder of 10 mile EPZ, and
. Advise the general public to administer KI CUE:
If necessary, direct the Candidate to perform downwind wedge determination as part of the PAR.
Comment:
.( Performance Step: 5 Determine downwind wedge.
Standard:
Standard:
Standard:
Candidate determines that the 150 elevation downwind sectors are C D E FG.
Candidate determines that the 500 elevation downwind sectors are DEFGH.
Candidate determines that the combined sectors are CDEFGH.
NOTE:
Time Critical - The Candidate has 15 minutes to complete the PAR determination.
NOTE:
Inform the Candidate that the Initial Notification Form will NOT be completed at this time.
Comment:
Terminating Cue:
STOP TIME:
When the candidate completes the Protective Action Recommendation, the evaluation for this JPM is complete.
BVPS-1 NRC ADMIN NO. 5 NUREG 1021, Revision 9
Appendix C Page 5 of 7 Form ES-C-1 VERIFICATION OF COMPLETION 2002 Audit A4 SRO Job Performance Measure No.:
2005 NRC SRO No. 5 Examinees Name:
Date Performed:
Facility Evaluator:
Number of Attempts:
Time to Complete:
Question Documentation:
Question:
Response
Result:
SAT UNSAT Examiners Signature:
Date:
BVPS-1 NRC ADMIN NO. 5 NUREG 1021, Revision 9
Appendix C Page 6 of 7 Form ES-C-1 2002 Audit A4 SRO JPM CUE SHEET INITIAL CONDITIONS:
(Emergency Classification)
The Unit was operating at 100% power for 160 days on-line when the following occurred:
EDG No. 1 was 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> into a maintenance outage to replace the motor driven fuel oil pump and not expected to return for another 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />.
A lightning strike in the switchyard resulted in a loss of offsite power and a reactor trip.
[ACB 1 F9], Emerg Gen 2 Circuit Breaker tripped on overcurrent de-energizing the 4KV 1 DF Bus.
30 minutes into the event, SPDS displays the 5 hottest CETs at greater than 720°F and RVLlS Full Range at 30%.
No 4KV emergency power is expected for at least another 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
INITIATING CUE:
As the Emergency Director, you are to evaluate the given plant conditions and determine the emergency classification in accordance with EPP/1-1 a, Recognition And Classification of Emergency Conditions. Report your results when finished.
BVPS-1 NRC ADMIN NO. 5 NUREG 1021, Revision 9
Appendix C Page 7 of 7 Form ES-C-1 JPM CUE SHEET 2002 Audit A4 SRO INITIAL CONDITIONS:
(Protective Action Recommendations)
A General Emergency has been declared at Unit 1 following a small break LOCA and the loss of all 4KV emergency power.
The following plant conditions exist:
. 35 wind direction is from 270Q at 4 MPH.
. 150 wind direction is from 27OQ at 1 1 MPH.
. 500 wind direction is from 285g at 15 MPH.
No radioactive release has occurred or is imminent (within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />).
. Health Physics has provided the following dose projections:
At the EAB:
11 REM TEDE; 8 REM CDE At 5 miles:
0.9 REM TEDE, 2.5 REM CDE At 2 miles:
1.5 REM TEDE; 4 REM CDE INITIATING CUE:
You are the Emergency Director and the TSC/EOF have NOT yet been activated. You are to evaluate the above conditions and determine which, if any, offsite Protective Action Recommendations are necessary.
BVPS-1 NRC ADMIN NO. 5 NUREG 1021, Revision 9