TABLE OF CONTENTS (continued) 3.4 REACTOR COOLANT SYSTEM (RCS)...............................................
3.4-1 3.4.1 RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits...............................................
3.4-1 3.4.2 RCS Minimum Temperature for Criticality...............................................
3.4-4 3.4.3 RCS Pressure and Temperature (PIT) Limits............................................... 3.4-5 3.4.4 RCS Loops -MODES 1 and 2..............................................
3.4-7 3.4.5 RCS Loops -MODE 3...............................................
3.4-8 3.4.6 RCS Loops - MODE 4...............................................
3.4-11 3.4.7 RCS Loops -MODE 5, Loops Filled...............................................
3.4-14 3.4.8 RCS Loops -MODE 5, Loops Not Filled..............................................
3.4-17 3.4.9 Pressurizer...............................................
3.4-19 3.4.10 Pressurizer Safety Valves..............................................
3.4-21 3.4.11 Pressurizer Power Operated Relief Valves (PORVs)................................... 3.4-23 3.4.12 Low Temperature Overpressure Protection (LTOP) System........................ 3.4-27 3.4.13 RCS Operational LEAKAGE...............................................
3.4-33 3.4.14 RCS Pressure Isolation Valve (PIV) Leakage.............................................. 3.4-35 3.4.15 RCS Leakage Detection Instrumentation...............................................
3.4-40 3.4.16 RCS Specific Activity..............................................
3.4-44 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS).......................................... 3.5-1 3.5.1 Accumulators...............................................
3.5-1 3.5.2 ECCS -Operating..............................................
3.5-4 3.5.3 ECCS -Shutdown..............................................
3.5-8 3.5.4 Refueling Water Storage Tank (RWST)................................
3.5-10 3.5.5 Seal Injection Flow...............................
3.5-12 3.6 CONTAINMENT SYSTEMS...............................
3.6-1 3.6.1 Containment................................
3.6-1 3.6.2 Containment Air Locks................................
3.6-2 3.6.3 Containment Isolation Valves...............................
3.6-7 3.6.4 Containment Pressure................................
3.6-16 3.6.5 Containment Air Temperature...............................
3.6-17 3.6.6 Containment Spray System................................
3.6-18 3.6.7 Spray Additive System...............................
3.6-20 (continued)
COMANCHE PEAK - UNITS I AND 2 ii Amendment No. 94,117
PAM Instrumentation 3.3.3 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C. One or more Functions C.1 Restore one channel to 7 days with two required channels OPERABLE status.
OR One required Thot channel and one required Core Exit Temperature channel inoperable.
OR One required Tcold channel and one required Steam Line Pressure channel for the associated loop inoperable.
D. Required Action and D.1 Enter the Condition Immediately associated Completion referenced in Table 3.3.3-1 Time of Condition C not for the channel.
met.
(continued)
I COMANCHE PEAK - UNITS 1 AND 2 3.3-36 Amendment No. a4,117
PAM Instrumentation 3.3.3 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME E. As required by Required E.1 Be in MODE 3.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> Action D.1 and referenced in Table 3.3.3-1.
AND E.2 Be in MODE 4.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> F.
As required by Required F.1 Initiate action in accordance Immediately Action D.1 and referenced with Specification 5.6.8.
in Table 3.3.3-1.
SURVEILLANCE REQUIREMENTS
NOTE--------------
SR 3.3.3.1 and SR 3.3.3.3 apply to each PAM instrumentation Function in Table 3.3.3-1.
SURVEILLANCE FREQUENCY SR 3.3.3.1 Perform CHANNEL CHECK for each required 31 days instrumentation channel that is normally energized.
SR 3.3.3.2 Deleted SR 3.3.3.3 Perform CHANNEL CALIBRATION.
18 months COMANCHE PEAK - UNITS 1 AND 2 3.3-37 Amendment No. 64,117
PAM Instrumentation 3.3.3 Table 3.3.3-1 (page 1 of 2)
Post Accident Monitoring Instrumentation FUNCTION
- 1.
Refueling Water Storage Tank Level
- 2.
Subcooling Monitors
- 3.
Reactor Coolant System (RCS) Hot Leg Temperature (Wide Range) (Tht.)
- 4.
RCS Cold Leg Temperature (Wide Range)
(Tw)
- 5.
RCS Pressure (Wide Range)
- 6.
- 7.
Containment Sump Water Level (Wide Range)
- 8.
Containment Pressure (Intermediate Range)
- 9.
Steam Line Pressure
- 10.
Containment Area Radiation (High Range)
- 11.
Deleted
- 12.
Pressurizer Water Level
- 13.
Steam Generator Water Level (Narrow Range)
- 14.
Condensate Storage Tank Level REQUIRED CHANNELS 2
2 1 per loop 1 per loop 2
2(a) 2 2
2 per steam line 2
2 2 per steam generator 2
CONDITION REFERENCED FROM REQUIRED ACTION D.1 E
E E
E E
F E
E E
F E
E E
(continued)
(a) A channel is eight sensors in a probe. A channel is OPERABLE if four or more sensors, one or more in the upper section and three or more in the lower section, are OPERABLE.
(b) Deleted I
COMANCHE PEAK - UNITS 1 AND 2 3.3-38 Amendment No. 64, 117
PAM Instrumentation 3.3.3 Table 3.3.3-1 (page 2 of 2)
Post Accident Monitoring Instrumentation FUNCTION REQUIRED CHANNELS CONDITION REFERENCED FROM REQUIRED ACTION D.1
- 15. Core Exit Temperature - Quadrant 1
- 16. Core Exit Temperature - Quadrant 2
- 17. Core Exit Temperature - Quadrant 3
- 18. Core Exit Temperature - Quadrant 4
- 19. Auxiliary Feedwater Flow
- a.
- b.
AFW Flow and Steam Generator Water Level (Wide Range) 2(c) 2(c) 2(c) 2(c) 2 per steam generator 1 each per steam generator E
E E
E E
E (c) A channel consists of two core exit thermocouples (CETs).
COMANCHE PEAK - UNITS 1 AND 2 3.3-39 Amendment No. 64 117