NLS2005032, Annual Radiological Environmental Operating Report
| ML051160385 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 04/20/2005 |
| From: | Fleming P Nebraska Public Power District (NPPD) |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| NLS2005032 | |
| Download: ML051160385 (199) | |
Text
Nebraska'Public Power District Aluays there when you need us NLS2005032 April 20, 2005 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001
Subject:
Annual Radiological Environmental Operating Report Cooper Nuclear Station, NRC Docket 50-298, DPR-46 The purpose of this letter is to submit the Cooper Nuclear Station (CNS) Annual Radiological Environmental Operating Report for the period of January 1, 2004, through December 31, 2004. The enclosed report is being submitted in accordance with CNS Technical Specification 5.6.2.
In accordance with 10 CFR 50.4(b)(1), we are enclosing one copy of the report for your use. We are also sending on copy to the Regional Office and one copy to the Senior Resident Inspector.
Should you have any questions regarding this submittal, please contact Mr. Paul Fleming, Licensing Manager, at 402-825-2774.
Licensing Manager
/clb Enclosure cc:
Regional Administrator w/enclosure USNRC - Region IV Senior Project Manager w/enclosure USNRC - NRR Project Directorate IV-1 Senior Resident Inspector w/enclosure USNRC NPG Distribution w/o enclosure Records w/enclosure
.J I
/) 4-,\\
COOPER NUCLEAR STATION P.O. Box 98/ Brownville, NE 68321-0098 Telephone: (402) 825-3811 / Fax: (402) 825-5211 wwwnppd.com
I ATTACHMENT 3 LIST OF REGULATORY COMMITMENTSl Correspondence Number: NLS2005032 The following table identifies those actions committed to by Nebraska Public Power District (NPPD) in this document. Any other actions discussed in the submittal represent intended or planned actions by NPPD. They are described for information only and are I not regulatory commitments. Please notify the Licensing Manager at Cooper Nuclear Station of any questions regarding this document or any associated regulatory commitments.
COMMITTED DATE COMMITMENT OR OUTAGE None I
PROCEDURE 0.42 l
REVISION 16 l
PAGE 19 OF26
NLS2005032 Enclosure Annual Radiological Environmental Operating Report Cooper Nuclear Station, NRC Docket 50-298, DPR46
NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION Radiological Environmental Monitoring Program 2004Annual Report January 1, 2004 to December 31, 2004 Approved by 4JJk Keith Jeter Cl Laboratory Director Prepared by Teledyne Brown Engineering 2508 Quality Lane Knoxvill, 7N37931-3133
TABLE OF CONTENTS SECTION TITLE PAGE Preface...........................................
6
- 1.
Introduction...........................................
7 II.
Summary...........................................
10 III.
Sampling and Analyses Program 12 IV.
Summary and Discussion of 2004 Analytical Results............................ 17 A. Airborne Particulates..........................................
18 B. Airborne Iodine..........................................
19 C. Fish..........................................
20 D. Milk - Nearest Producer..........................................
20 E. Milk - Other Producers..........................................
21 F. Ground Water..........................................
22 G. River Water..........................................
23 H. Thermoluminescent Dosimeters..........................................
23 I. Food - Broadleaf Vegetation..........................................
24 J. Shoreline Sediment..........................................
25 V.
Conclusions..........................................
26 VI.
Radiological Environmental Monitoring Program Summary Table - 2004..........................................
28 VII.
Complete Data Tables..........................................
33 VIII.
References.90 2
TABLE OF CONTENTS (Cont)
APPENDICES APPENDIX A - 2004 Land Use Census.................................................
A-1 APPENDIX B - Summary of Interlaboratory Comparisons............................... B-i APPENDIX C - Synopsis of Analytical procedures........................................... C-1 APPENDIX D - Detection Limits and Reporting Levels.....................
............. D-1 APPENDIX E - REMP Sampling and Analytical Exceptions............................ E-i APPENDIX F - Summary of Doses to a Member of the Public Offsite............. F-i APPENDIX G - REMP Sample Station Descriptions....................................... G-1 LIST OF FIGURES
- 1.
Map of Sampling Stations.................................................
15 3
TABLE OF CONTENTS (Cont)
LIST OF TRENDING GRAPHS
- 1.
Gross Beta in Air Particulates..............................................
19
- 2.
Iodine-131 in Charcoal Filters..............................................
19
- 3.
Cesium-137 in Fish..............................................
20
- 4.
Iodine-131 and Cesium-137 in Milk -Nearest Producer.......................... 21
- 5.
Iodine-131 and Cesium-137 in Milk - Other Producers............................ 22
- 6.
Tritium in Ground Water..............................................
22
- 7.
Tritium in River Water..............................................
23
- 8.
Thermoluminescent Dosimetry..............................................
24
- 9.
Iodine-131 and Cesium-137 in Food - Broadleaf Vegetation................... 24
- 10.
Iodine-131, Cesium-134, and Cesium-137 in Shoreline Sediment............ 25 4
TABLE OF CONTENTS (Cont)
LIST OF TABLES 1
Sampling Schedule and Analyses...............................................
14 VII-1 Exposure Pathway - Airborne Air Particulate & Charcoal Filters...... 34 VII-2 Exposure Pathway - Airborne Composite Air Particulate Filters....... 54 VII-3 Exposure Pathway - Ingestion Fish...............................................
64 VII-4 Exposure Pathway - Ingestion Milk Nearest Producer....................... 66 VII-5 Exposure Pathway - Ingestion Milk Other Producers......................... 71 VII-6 Exposure Pathway - Ingestion Water - Ground.................................. 74 VII-7 Exposure Pathway - Ingestion Water - River..................................... 76 VII-8 Exposure Pathway - Thermoluminescent Dosimetry - TLD.............. 82 VII-9 Exposure Pathway - Ingestion Vegetation - Terrestrial, Broadleaf.... 84 VII-10 Exposure Pathway - Airborne Shoreline Sediment............................. 88 5
PREFACE This report covers the period of January I through December 31, 2004. Personnel of the Nebraska Public Power District made all sample collections. Analyses were performed and reports of analyses were prepared by Teledyne Brown Engineering -
Environmental Services and forwarded to Nebraska Public Power District. Environmental Thermoluminescent Dosimeter (TLD) analyses were performed and reports of analyses were prepared by Proxtronics, Inc.
6
SECTION]. INTRODUCTION 7
I. INTRODUCTION This report contains a complete tabulation of data collected during the period January through December 2004, for the operational Radiological Environmental Monitoring Program performed for the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) by Teledyne Brown Engineering - Environmental Services.
Cooper Nuclear Station is located in Nemaha County in the southeast corner of Nebraska on the Missouri River. A portion of the site extends into Missouri. The reactor is a 778-megawatt (net electrical) boiling water reactor. Initial criticality was attained on February 21, 1974. The reactor reached 50 percent power on June 25, 1974 and 100 percent power on November 20, 1974.
Radiological environmental monitoring began in 1971 before the plant became operational and has continued to the present. The program monitors radiation levels in air, terrestrial and aquatic environments. All samples are collected by NPPD personnel.
All samples are shipped for analysis to a contractor's laboratory where there exists special facilities required for measurements of extremely low levels of radioactivity. From 1971 through 1976 the contractor was Teledyne Isotopes, Westwood, New Jersey. NALCO Environmental Sciences assumed responsibility for the analyses effective January 1, 1977.
On November 1, 1978 Hazelton Environmental Sciences Corporation (HESC) assumed responsibility for the program.
Prior to November 1, 1978 Hazelton Environmental Sciences operated as NALCO Environmental Sciences.
Teledyne Isotopes (now trading as Teledyne Brown Engineering - Environmental Services) again assumed responsibility for the analyses effective January 1, 1979 through December 31, 2004.
The United States Nuclear Regulatory Commission (USNRC) regulations (10CFR50.34a) require that nuclear power plants be designed, constructed, and operated to keep levels of radioactive material in effluents to unrestricted areas as low as is reasonably achievable (ALARA). To ensure these criteria are met, the operating license for Nebraska Public Power District's Cooper Nuclear Station includes the Technical Requirement Manual, which addresses the release of radioactive effluents.
Inplant monitoring is used to ensure that these release limits are not exceeded. As a precaution against unexpected or undefined environmental processes, which might allow undue accumulation of radioactivity in the environment, a program for monitoring the plant environs is also included in NPPD's CNS Offsite Dose Assessment Manual (ODAM).
8
A.
Atmospheric Nuclear Tests Three atmospheric nuclear detonations in the People's Republic of China influenced program results significantly in late 1976 and in 1977.
Two of these detonations occurred in late 1976 (September 26 and November 17) and one in late 1977 (September 17). As a consequence of these tests elevated activities of gross beta in air particulate filters and I-131 in milk were observed throughout most of the United States.
No atmospheric nuclear tests have been conducted since 1980, thus no short-lived fission products were detected in air particulate samples.
On April 26, 1986 the fire and explosion of Chernobyl Reactor No. 4 in the Soviet Union resulted in the release of fission products to the atmosphere and worldwide fallout.
Following the explosion, elevated levels of gross beta activities in air particulates and Iodine-131 in charcoal filters and milk samples were measured. Additionally, in 1986, Cesium-137 and the short-lived radionuclides Iodine-131, Ruthenium-106, and Cesium-134 were detected in broadleaf vegetation. Similar results occurred in other areas of the United States and the entire Northern Hemisphere.
B.
Program Obiectives and Data Interpretation The objective of the monitoring program is to detect and assess the impact of possible releases to the environs of radionuclides from the operations of the Cooper Nuclear Station. This objective requires measurements of low levels of radioactivity equal to or lower than pre-determined limits of detection. In addition the source of the environmental radiation must be established. Sources of environmental radiation include:
(1)
Natural background radiation from cosmic rays (Beryllium-7).
(2)
Terrestrial, primordial radionuclides from the environment (potassium-40, radium-226, thorium-228).
(3)
Fallout from atmospheric nuclear tests such as the September 1977 detonation by the Peoples' Republic of China and the atmospheric weapons test of October 16, 1980 (fission products and fusion products).
(4)
Releases from nuclear power plants such as CNS (fission products and neutron activation products).
(5)
Fallout from the Chernobyl Nuclear Reactor Accident.
Radiation levels measured in the vicinity of an operating power station are compared with preoperational measurements at the same locations to distinguish power plant effects from other sources. Also, results of the monitoring program are related to events known to cause elevated levels of radiation in the environment, e.g., atmospheric nuclear detonations or abnormal plant releases.
9
SECTION 11.
SUMMARY
10
II.
SUMMARY
Presented in this report are summaries and discussions of the data generated for the Radiological Environmental Monitoring Program (REMP) for the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) for 2004.
The sampling and analyses program is described in Section III. It contains the sampling schedule and required analyses in Table I and the site map.
A discussion of each type of sample analyzed and its impact, if any, on the environment is presented in Section IV.
Included are graphs of the radionuclides of interest for the past several years and the statistical results for each quarter of the year.
Section V presents the yearly conclusions of the program.
Section VI is the Radiological Environmental Monitoring Program Summary. It contains the yearly summary of the program with the total number of samples of each type analyzed.
It lists the yearly average and range for the control locations versus the indicator locations and the number of detections per total number of samples. It identifies the station with the highest yearly average, the distance and location of that station and provides the range of detection.
Section VII contains the complete data tables for the period.
References are presented in Section VIII.
11
SECTION III. SAMPLING AND ANALYSES PROGRAM 12
III.
SAMPLING AND ANALYSES PROGRAM The 2004 sampling and analyses program is described in Table 1. Teledyne Brown Engineering Environmental Services has a
comprehensive quality assurance/quality control program designed to assure the reliability of data obtained. The results for the 2004 Interlaboratory Comparison Program conducted by the Analytics',
Inc., DOE/EML, MAPEP and Environmental Resource Associates are contained in Appendix B.
Sampling locations are indicated in the map labeled Figure 1. The sample types collected at each location and the approximate distance and direction from the reactor elevated release point are specified.
The annual land use census for 2004 is described in Appendix A. There were no milk animals found within three miles of CNS in 2004 and no evidence of potable water use from the river. The nearest garden to CNS is in sector L, 1.3 mile from CNS.
Gardens were found in nine sectors during 2000, in eight sectors during 2001, in seven sectors during 2002, in eight sectors during 2003, and in nine sectors during 2004. The nearest resident to CNS is in sector Q, 0.9 miles from CNS.
All of the required 2004 environmental monitoring, including sampling and analyses, was conducted as specified in Table D4.1-1 of the CNS Offsite Dose Assessment Manual (ODAM), except as noted in Appendix E, REMP Sampling and Analytical Exceptions table.
13
TABLE I NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION Environmental Radiation Surveillance Program Sampling Schedule and Analyses Sample Type Airborne/
Particulate Airborne/lodine Milk / Nearest Producer peak pasture only River Water Milk/ Nearest Producer Non-peak pasture Food Products / Broadleaf Vegetation Background Radiation Thermoluminescent Dosimeters Groundwater Milk Other Producers Fish (Summer and Fall)
Shoreline Sediment Station 1-10 Frequency Once per 7 days 1-10 99 Once per 7 days Once per 15 days 28,35 Once per 31 days 99 Once per 31 days Analyses Gross beta. Gamma Isotopic on quarterly composite of each station, and on each sample in which gross beta activity is >10 times the yearly mean of control samples 1-131 1-131 (low level), Gamma Isotopic analysis of each sample Gamma Isotopic, each sample Tritium on quarterly composite 1-13 1 (low level), Gamma Isotopic analysis of each sample 1-131 (low level), Gamma Isotopic analysis of each sample TLD Readout (gamma dose) 1-131 (low level), Gamma Isotopic, Tritium 1-131 (low level), Gamma Isotopic Gamma Isotopic on edible portions Gamma Isotopic 28,35,96,101 1-10,20,44,56,58,59, 66,67, 71,79-91,94 11,47 100,102,103 28,35 28,35 Monthly when required Once per 92 days Once per 92 days Once per 92 days Two times per year Two times per year 14
SECTION IV.
SUMMARY
AND DISCUSSION OF 2004 ANALYTICAL RESULTS 17
IV.
SUMMARY
AND DISCUSSION OF 2004 ANALYTICAL RESULTS Data from the radiological analyses of environmental media collected during 2004 are tabulated and discussed below. The procedures and specifications followed in the laboratory for these analyses are as required in the Teledyne Brown Engineering Quality Assurance manual and are explained in the Teledyne Brown Engineering Analytical Procedures. A synopsis of analytical procedures used for the environmental samples is provided in Appendix C. In addition to internal quality control measures performed by Teledyne, the laboratory also participates in an Interlaboratory Comparison Program.
Participation in this program ensures that independent checks on the precision and accuracy of the measurements of radioactive material in environmental samples are performed. The results of the Interlaboratory Comparison are provided in Appendix B.
Radiological analyses of environmental media characteristically approach and frequently fall below the detection limits of state-of-the-art measurement methods. The "less than" values in the data tables were calculated from each specific analysis and are dependent on sample size, detector efficiency, length of counting time, chemical yield (when appropriate) and the radioactive decay factor from time of counting to time of collection.
Teledyne Brown Engineering's analytical methods meet or are below the Lower Limit of Detection (LLD) requirements given in Table 2 of the USNRC Branch Technical Position, Radiological Monitoring Acceptable Program (November 1979, Revision 1). Section C contains a discussion of the LLD formulas.
The following is a discussion and summary of the results of the environmental measurements taken during the 2004 reporting period:
A.
Airborne Particiuates Gross beta activity was observed in 520 of the 520 indicator samples collected during 2004. The average concentration was 0.022 pCi/m3 with a range of 0.007 to 0.060 pCi/M3. The results of the gross beta activities are presented in Section VII-1 and Trending Graph 1. The gross beta activities for 2004 were comparable to levels measured in the previous several years. Prior to that period the gross beta activities were higher due to atmospheric nuclear weapons testing performed in other countries. The preoperational period of 1971 through 1974 averaged 0.098 pCi/M3 gross beta.
Air particulate filters were collected weekly and composited by locations on a quarterly basis. They were analyzed by gamma ray spectroscopy. The results are presented in Section VII-2. Beryllium-7, which is produced continuously in the upper atmosphere by cosmic radiation, was measured in 40 of 40 composite samples. The indicator locations had an average concentration of 0.118 pCi/M3 with a range of 0.070 to 0.153 pCi/M3. During the preoperational period, beryllium-7 was measured at comparable levels. All other gamma emitters were below the detection limits.
18
TRENDING GRAPH I GROSS BETA IN AIR PARTICULATES MONTHLY AVERAGE - ALL LOCATIONS Gross Beta 1
0.1 0.0 X
0.001 0.0001 G
Be 0.
0001 i
I I
- p.
Itpa w p p ~ sp M~h~t0>5t~t%05Xb~~z>Mt~ts0uth~iN0° ~ 'so SI' -o5° A c ~ P" S3 pub Station 611-131 -- Station 61 Cs-1 37 A-Station 991-131 Station 99 Cs-137 I -- 1-1 31 ODAM LLD - Cs-137 ODAM LLD Station 61 went out of business in May of 2003. Station 99 replaced station 61 in May of 2003. E. AMilk - Other Producers Eight milk samples were collected from three locations of other producers during 2004 and results are presented in Table V1I-5 and Trending Graph 5. Station 100 was sampled in January and March 2004 before going out of business. Station 102 was sampled quarterly in 2004. Station 103 replaced station 100 and was sampled in July and October 2004. Naturally occurring potassium-40 was detected in all eight samples analyzed with an average concentration of 1258 pCi/liter and a range of 1170 to 1360 pCi/liter. Station 102 had the highest average concentration of 1275 pCi/liter with a range of 1240 to 1350 pCi/liter. All other gamma emitters were below their detection levels. The operation of the Cooper Nuclear Station has no discemable impact on milk samples. 21 TRENDING GRAPH 5 IODINE-131 AND CESIUM-137 IN MILK - OTHER PRODUCERS QUARTERLY AVERAGE - ALL LOCATIONS 100.0 1) SLC-, 10.0 1.0
- I 0.1
-13 C S -10 3 SP -SU C Sif 1 i s g t I- + 1-1 31 - CS-1 37 A 1-1 31 ODAM LLD --- Cs-1 37 ODAM LLD I Due to delay in analysis, sample results for I-131 for the first quarter of 2001 were excluded and are not plotted. F. Ground Water Groundwater was collected from two stations quarterly and analyzed for tritium and for gamma emitting radionuclides. Station 11 is located 0.15 miles from the plant and station 47 is 25.8 miles from the plant. The results are presented in Table VII-6 and Trending Graph 6. Thorium-228 was measured in one of the indicator samples with a concentration of 115 pCi/liter. All other gamma emitters were below their detection limits. TRENDING GRAPH 6 TRITIUM IN GROUND WATER QUARTERLY AVERAGE - ALL LOCATIONS 10000.0 S C1. 1000.0 100.0 MWORNMEMENNEMONEW" 10.0 0 0 q q 0 0 0 ?§ o& ~'0 0 0 l--_H-3-* H-3ODAMLLD l 22 G. River W'ater River water was collected monthly and monitored for gamma emitting radionuclides. A quarterly composite was measured for tritium. The results are presented in Table VII-7 and Trending Graph 7. There were no radionuclides measured above their detection levels. TRENDING GRAPH 7 TRITIUM IN RIVER WATER QUARTERLY AVERAGE - ALL LOCATIONS 10000.0 1000.0 5 100.0 10.0 - .0 + -- H-3 -_-H-3 ODAM LLD H. Thermoluminescent Dosimeters Thermoluminescent dosimeters (TLDs) determine environmental radiation doses and the results are presented in Table VII-8 and Trending Graph 8. Ambient radiation was monitored at 32 locations within a 10 mile radius of the Cooper Nuclear Station and collected quarterly. The quarterly average for the indicator locations was 7.6 millirem/quarter and a range from 0.8 to 19.2 millirem/quarter. The control station 44, which is located 10.5 miles, 270 degrees had an average of 9.3 millirem/quarter and a range from 4.4 to 12.8 millirem/quarter. The highest station was Station 56 with an average of 10.3 millirem/quarter and a range from 4.3 to 17.3 millirem/quarter. The preoperational period of 1971 through 1974 averaged 7.0 millirem/quarter. The data from year to year is in good agreement and indicates no adverse changes in radiation exposure to the population near the Cooper Nuclear Station. 23 TRENDING GRAPH 8 THERMOLUMINESCENT DOSIMETRY QUARTERLY AVERAGE - ALL LOCATIONS 1000 0, E 100 10 0~
- 1
--+ Exposure Pathway - Arrbient Gan-ra Radiation: L)Dl I. Food - Broadleaf Vegetation As stated in the CNS ODAM vegetation samples are not required as long as milk samples are available. Even though no vegetation samples were analyzed, vegetation table V11-9 and Trending Graph 9 are included in this report. All gamma emitters were below their detection levels. TRENDING GRAPH 9 IODINE-131 AND CESIUM-137 IN FOOD - BROADLEAF VEGETATION ALL LOCATIONS 10o0.0o e I-t3e / e / 0/ / e l 1-4-1-131 1-131 ODAM LLD -4*-CS-137 C9-137 01AM ~LW The low Cs-137 value reported in July 2001 was due to the wrong aliquot being entered for the gamma analysis. Due to delay in sample receipt, the 1-131 had decayed away, resulting in a high LLD for May 2002. 24 J. Shoreline Sediment Sediment samples were collected during May and October from Stations 28 and 35 and were analyzed by gamma spectrometry. The results are presented in Table VII-10 and Trending Graph 10. One man-made and a number of naturally occurring radionuclides were detected in these samples. Cesium-137 was detected in both indicator samples with an average concentration of 70.9 pCi/kg (dry weight) and a range of 62.7 to 79.0 pCi/kg (dry weight), which is less than the ODAM LLD. Naturally occurring potassium-40 was observed in all samples. The average concentration for the two supplemental stations was 10130 pCi/kg (dry weight) with a range of 5060 to 15200 pCi/kg (dry weight). The average concentration for the two indicator stations was 15200 pCi/kg (dry weight) with a range of 14600 to 15800 pCi/kg (dry weight). Beryllium-7, which is produced continuously in the upper atmosphere by cosmic radiation, was measured in one indicator sample with a concentration of 550 pCi/kg (dry weight). Radium-226 was measured in one of the control samples with a concentration of 424 pCi/kg (dry weight) and one indicator sample with a concentration of 1950 pCi/kg (dry weight). Thorium-228 was measured in all samples. The supplemental station had an average thorium-228 concentration of 1544 pCi/kg (dry weight) and a range of 588 to 2500 pCi/kg (dry weight). The indicator station had an average thorium-228 concentration of 2490 pCi/kg (dry weight) and a range of 2370 to 2610 pCi/kg (dry weight). All other gamma emitters were below their detection limits. TRENDING GRAPH 10 IODINE-131, CESIUNI-134, AND CESIUNI-137 IN SHORELINE SEDIMENT STATIONS 28 AND 35 1000.000 100.000 10.000 1.000I,.,I 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 I-131 --*Cs-134 A Cs-137 -+-Cs-134 ODAM LLD -- Cs-137 ODAM LLD Due to delay in analysis, sample results for 1-131 for the second quarter of 2000 were excluded and are not plotted. The ODAM does not list an LLD for 1-131. 25 SECTION V. CONCLUSIONS 26 V. CONCLUSIONS The results of the 2004 Radiological Environmental Monitoring Program (REMP) for the Cooper Nuclear Station (CNS) of the Nebraska Public Power District (NPPD) have been presented. The report contains data tables, summaries, and discussions of the data and trending graphs. Naturally occurring radioactivity and residual traces of fallout were observed in sample media in the expected ranges. They have been discussed individually in the text. Observed radioactivity was at very low concentrations. The results of the analyses have been presented. Based on the evidence of the Radiological Environmental Monitoring Program, the Nebraska Public Power District, Cooper Nuclear Station has had no discernable radiological impact on the environment and is operating within regulatory limits. 27 SECTION VI. RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
SUMMARY
TABLE - 2004 28
ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM SUIMIMARY Name of Facility Location of Facility Cooper Nuclear Station Nemaha, Nebraska (County, State)
Docket No.
50-298 Reporting Period January 1, 2004 to December 31, 2004 Type &
Lower Limit All Indicator Control Medium of Pathway Total No.
of Locations Location with Hihest Annual Mean Location No. of Sampled of Analyses Detection (I)
Mean (2)
Name Mean ( ) (2)
Mean ( ) (2)
Reportable (Unit of Measurement)
Performed (LLD)
Range (2)
Range (2)
Range (2)
Occurrences Air Iodine (pCi/m3) 1-131 520 0.07 ND (0/520)
(ND-ND)
NA NA NA(0/0)
(NA-NA)
(NA-NA) 0 Air Particulate (pCi/m3)
Gross Beta (Weekly)
Be-7 520 0.01 0.022(520/520)
(0.007-0.060) 40 NA 0.118(40/40)
(0.070-0.153)
Sta. 9 7.3 mi.
Sta. 9 7.3 mi.
NA 0.023(52/52)
(0.012-0.060) 0.129(4/4)
(0.115-0.143)
NA (0/0)
(NA-NA)
NA (0/0)
(NA-NA) 0 0
0 t0 No Co-60 40 NA ND (0/40)
(ND-ND)
NA NA(0/0)
(NA-NA)
(NA-NA)
Th-228 40 NA ND (0/40)
(ND-ND)
NA NA NA(0/0)
(NA-NA)
(NA-NA) 0 Fish (pCi/kg wet)
K-40 8
NA 3258(4/4)
(2800-3490)
Sta. 28 1.8 mi.
3258(4/4) 3203(4/4)
(2800-3490)
(2980-3520) 0 Co-60 8
130 ND (0/4)
(ND-ND)
Cs-137 8
150 ND(0/4)
(ND-ND)
NA NA NA ND(0/4)
(NA-NA)
(ND-ND)
NA ND(0/4)
(NA-NA)
(ND-ND) 0 0
(I) Nominal Lower Limit of Detection (LLD), as stated in ODAM.
(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in bracketso.
(4) ND = Non Detectable.
(5) NA -Not Applicable.
ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM SUMNUMARY Name of Facility Location of Facility Cooper Nuclear Station Nemaha, Nebraska (County, State)
Docket No.
50-298 Reporting Period January 1, 2004 to December 31, 2004 Type &
Lower Limit All Indicator Control Medium of Pathway Total No.
of Locations Location with Hiehest Annual Mean Location No. of Sampled of Analyses Detection (1)
Mean (2)
Name Mean ( ) (2)
Mean ( ) (2)
Reportable (Unit of Measurement)
Performed (LLD)
Range (2)
Range (2)
Range (2)
Occunences Fish (pCi/kg wet)
Th-228 8
NA ND (0/4)
(ND-ND)
NA NA ND (0/4)
(NA-NA)
(ND-ND) 0 Milk Nearest Producers (pCi/liter) 1-131 K-40 17 1.0 ND (0/17)
(ND-ND) 17 NA 1279(17/17)
(1120-1390)
NA Sta. 99 10.3 mi.
NA NA (0/0)
(NA-NA)
(NA-NA) 1279(17/17)
NA (0/0)
(1120-1390)
(NA-NA) 0 0
w Ra-226 17 NA ND (0/17)
(ND-ND)
NA NA NA (0/0)
(NA-NA)
(NA-NA) 0 Milk Other Producers (pCi/liter) 1-131 K-40 8
1.0 ND (0/8)
(ND-ND) 8 NA 1258(8/8)
(1170-1360)
NA Sta. 102 11.5 mi.
NA NA (0/0)
(NA-NA)
(NA-NA) 1275(4/4)
NA (0/0)
(1240-1350)
(NA-NA) 0 0
Th-228 8
NA ND (0/8)
(ND-ND)
NA NA NA NA (0/0)
(NA-NA)
(NA-NA)
NA NA (0/0)
(NA-NA)
(NA-NA) 0 0
Groundwater (pCi/liter)
H-3 8
2000 ND (0/8)
(ND-ND)
(I) Nominal Lower Limit of Detection (LLD), as stated in ODAM.
(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in brackets0.
(4) ND -Non Detectable.
(5) NA = Not Applicable.
ENVIRONMENTAL RADIOLOGICAL MNIONITORING PROGRAM SUMIMARY Name of Facility Location of Facility Cooper Nuclear Station Nemaha, Nebraska (County, State)
Docket No.
50-298 Reporting Period January 1,2004 to December 31.2004 Type &
Lower Limit All Indicator Control Medium of Pathway Total No.
of Locations Location with Hlighest Annual Mean Location No. of Sampled ofAnalyses Detection (I)
Mean (2)
Name Mean () (2)
Mean () (2)
Reportable (Unit of Measurement)
Pcrformed (LLD)
Range (2)
Range (2)
Range (2)
Occurrences Groundwater (pCi/liter)
K-40 8
NA ND (0/8)
(ND-ND)
NA NA NA (0/0)
(NA-NA)
(NA-NA) 0 Th-228 8
NA 115(1/8)
(NA-NA)
Sta. 47 25.8 mi.
115(1/8)
NA (0/0)
(NA-NA)
(NA-NA) 0 w
River Water (pCi/liter) 11-3 8
2000 ND (0/4)
(ND-ND)
K-40 24 NA ND(0/12)
(ND-ND)
Th-228 24 NA ND(0/12)
(ND-ND)
NA NA NA NA ND (0/4)
(NA-NA)
(ND-ND)
NA ND(0/12)
(NA-NA)
(ND-ND)
NA ND (0/12)
(NA-NA)
(ND-ND) 0 0
0 Thermoluminescence Gamma Dosimeter Dose (mR/Standard Quarter) Quarterly Shoreline Sediment Bc-7 (pCi/kg dry) 128 NA 7.6(124/124)
(0.8-19.2) 4 NA 550(1/2)
(NA-NA)
Sta. 56 1.9 mi.
Sta. 28 1.8 mi.
10.3(4/4) 9.3(4/4)
(4.3-17.3)
(4.4-12.8) 550(1/2)
ND (0/2)
(NA-NA)
(ND-ND) 0 0
(l) Nominal Lower Limit of Detection (LLD), as stated in ODAM.
(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in bracketso.
(4) ND - Non Detectable.
(5) NA= Not Applicable.
ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM SUMIMIARY Name of Facility Location of Facility Cooper Nuclear Station Nemaha, Nebraska Docket No.
50-298 Reporting Period January 1,2004 to December 31, 2004 (County, State)
Type &
Lower Limit All Indicator Control Medium of Pathway Total No.
of Locations Location with Highest Annual Mean Location No. of Sampled of Analyses Detection (I)
Mean (2)
Name Mean ( ) (2)
Mean () (2)
Reportable (Unit of Measurement)
Performed (LLD)
Range (2)
Range (2)
Range (2)
Occurrences Shoreline Sediment (pCi/kg dry)
K-40 4
NA 15200(2/2)
(14600-15800)
Sta. 28 1.8 mi.
15200(2/2) 10130(2/2)
(14600-15800) (5060-15200) 0 Cs-137 4
180 70.9(2/2)
(62.7-79.0)
Sta. 28 1.8 mi.
Sta. 28 1.8 mi.
70.9(2/2)
ND (0/2)
(62.7-79.0)
(ND-ND) 1950(1/2) 424(1/2)
(NA-NA)
(NA-NA) 0 0
w Ra-226 4
NA 1950(1/2)
(NA-NA)
Th-228 4
NA 2490(2/2)
(2370-2610)
Sta. 28 1.8 mi.
2490(2/2) 1544(2/2)
(2370-2610)
(588-2500) 0 (I) Nominal Lower Limit of Detection (LLD), as stated in ODAM.
(2) Mean and Range based upon detectable measurements only. Fraction of detectable measurements at specified location indicated in bracketso.
(4) ND - Non Detectable.
(5) NA -Not Applicable.
SECTION VII. COMPLETE DATA TABLES 33
VII-'
NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 01 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
12/30 01/06 1.00E+04 CU. FT.
3.50E-02 +/- 4.96E-03 L.T. 2.E-02 01/06 01/13 1.OOE+04 CU. FT.
3.96E-02 +/- 5.37E-03 L.T. 3.E-02 01/13 01/20 1.01E+04 CU. FT.
3.30E-02 +/- 4.76E-03 L.T. 1.E-02 01/20 01/28 1.15E+04 CU. FT.
2.15E-02 +/- 3.89E-03 L.T. 1.E-02 01/28 02/04 9.93E+03 CU. FT.
4.40E-02 +/- 5.54E-03 L.T. 1.E-02 02/04 02/11 1.OOE+04 CU. FT.
3.80E-02 +/- 5.32E-03 L.T. 2.E-02 02/11 02/17 8.68E+03 CU. FT.
2.57E-02 +/- 4.83E-03 L.T. 1.E-02 02/17 02/24 1.04E+04 CU. FT.
2.92E-02 +/- 4.78E-03 L.T. 1.E-02 02/24 03/02 9.75E+03 CU. FT.
1.35E-02 +/- 3.63E-03 L.T. 11.E-02 03/02 03/09 1.OOE+04 CU. FT.
1.24E-02 +/- 3.60E-03 L.T. 2.E-02 03/09 03/16 1.01E+04 CU. FT.
2.45E-02 +/- 4.47E-03 L.T. 9.E-03 03/16 03/23 1.OOE+04 CU. FT.
1.54E-02 +/- 3.72E-03 L.T. 3.E-02 03/23 03/30 1.OOE+04 CU. FT.
1.33E-02 +/- 3.43E-03 L.T. 3.E-02 03/30 04/06 1.01E+04 CU. FT.
2.14E-02 +/- 4.34E-03 L.T. 9.E-03 04/06 04/12 8.58E+03 CU. FT.
1.88E-02 +/- 4.40E-03 L.T. 3.E-02 04/12 04/20 1.14E+04 CU. FT.
2.90E-02 +/- 4.33E-03 L.T. 2.E-02 04/20 04/27 9.99E+03 CU. FT.
1.18E-02 +/- 3.33E-03 L.T. 4.E-02 04/27 05/04 1.01E+04 CU. FT.
1.76E-02 +/- 3.85E-03 L.T. 3.E-02 05/04 05/11 9.98E+03 CU. FT.
2.29E-02 +/- 4.63E-03 L.T. 1.E-02 05/11 05/19 1.15E+04 CU. FT.
1.61E-02 +/- 3.64E-03 L.T. 2.E-02 05/19 05/25 8.63E+03 CU. FT.
1.54E-02 +/- 3.90E-03 L.T. 2.E-02 05/25 06/01 1.OOE+04 CU. FT.
1.23E-02 +/- 3.46E-03 L.T. 1.E-02 06/01 06/08 1.01E+04 CU. FT.
1.48E-02 +/- 3.97E-03 L.T. 1.E-02 06/08 06/14 8.53E+03 CU. FT.
1.58E-02 +/- 4.03E-03 L.T. 2.E-02 06/14 06/22 1.15E+04 CU. FT.
1.53E-02 +/- 3.22E-03 L.T. 2.E-02 06/22 06/29 1.02E+04 CU. FT.
2.01 E-02 +/- 4.13E-03 L.T. 2.E-02
VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 01 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
06/29 07/06 9.85E+03 CU. FT.
1.26E-02 +/- 3.75E-03 L.T. 3.E-02 07/06 07/13 1.00E+04 CU. FT.
1.73E-02 +/- 3.89E-03 L.T. 2.E-02 07/13 07/19 8.65E+03 CU. FT.
1.69E-02 +/- 4.34E-03 L.T. 3.E-02 07/19 07/27 1.14E+04 CU. FT.
2.12E-02 +/- 3.70E-03 L.T. 2.E-02 07/27 08/03 1.00E+04 CU. FT.
2.43E-02 +/- 4.51E-03 L.T. 4.E-02 08/03 08/10 1.00E+04 CU. FT.
1.58E-02 +/- 3.87E-03 L.T. 3.E-02 08/10 08/17 1.00E+04 CU. FT.
1.84E-02 +/- 4.OOE-03 L.T. 1.E-02 08/17 08/24 1.OOE+04 CU. FT.
2.06E-02 +/- 4.13E-03 L.T. 1.E-02 08/24 08/31 1.00E+04 CU. FT.
1.82E-02 +/- 3.87E-03 L.T. 3.E-02 08/31 09/07 1.01E+04 CU. FT.
2.71E-02 +/- 4.43E-03 L.T. 1.E-02 09/07 09/14 1.OOE+04 CU. FT.
1.72E-02 +/- 4.24E-03 L.T. 2.E-02 09/14 09/21 1.01E+04 CU. FT.
1.42E-02 +/- 3.72E-03 L.T. 3.E-02 09/21 09/27 8.55E+03 CU. FT.
2.77E-02 +/- 4.99E-03 L.T. 1.E-02 09/27 10/05 1.14E+04 CU. FT.
2.47E-02 +/- 4.14E-03 L.T. 4.E-02 10/05 10/13 1.15E+04 CU. FT.
1.70E-02 +/- 3.69E-03 L.T. 1.E-02 10/13 10/19 8.59E+03 CU. FT.
1.88E-02 +/- 4.21E-03 L.T. 3.E-02 10/19 10/26 1.01E+04 CU. FT.
2.23E-02 +/- 4.08E-03 L.T. 3.E-02 10/26 11/02 9.98E+03 CU. FT.
2.06E-02 +/- 4.03E-03 L.T. 2.E-02 11/02 11/09 1.OOE+04 CU. FT.
2.55E-02 +/- 4.51E-03 L.T. 3.E-02 11/09 11/16 1.OOE+04 CU. FT.
2.80E-02 +/- 4.56E-03 L.T. 2.E-02 11/16 11/23 1.OOE+04 CU. FT.
2.29E-02 +/- 4.20E-03 L.T. 2.E-02 11/23 11/30 1.01E+04 CU. FT.
2.21E-02 +/- 4.15E-03 L.T. 4.E-02 11/30 12/07 9.96E+03 CU. FT.
4.23E-02 +/- 5.49E-03 L.T. 3.E-02 12/07 12/13 8.65E+03 CU. FT.
3.40E-02 +/- 6.53E-03 L.T. 2.E-02 12/13 12/21 1.15E+04 CU. FT.
2.12E-02 +/- 3.76E-03 L.T. 1.E-02 12/21 12/28 1.01 E+04 CU. FT.
3.82E-02 +/- 5.39E-03 L.T. 3.E-02
VI-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 02 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
12/30 01/06 1.01E+04 CU. FT.
3.89E-02 +/- 5.17E-03 L.T. 2.E-02 01/06 01/13 9.97E+03 CU. FT.
4.67E-02 +/- 5.76E-03 L.T. 3.E-02 01/13 01/20 1.01 E+04 CU. FT.
3.40E-02 +/- 4.82E-03 L.T. 1.E-02 01/20 01/28 1.15E+04 CU. FT.
2.41E-02 +/- 4.06E-03 L.T. 1.E-02 01/28 02/04 9.93E+03 CU. FT.
3.96E-02 +/- 5.30E-03 L.T. 1.E-02 02/04 02/11 1.OOE+04 CU. FT.
4.44E-02 +/- 5.66E-03 L.T. 1.E-02 02/11 02/17 8.69E+03 CU. FT.
2.88E-02 +/- 5.04E-03 L.T. 1.E-02 w
02/17 02/24 1.04E+04 CU. FT.
2.60E-02 +/- 4.59E-03 L.T. 1.E-02
+/-
02/24 03/02 9.57E+03 CU. FT.
1.44E-02 +/- 3.75E-03 L.T. 1.E-02 03/02 03/09 1.OOE+04 CU. FT.
1.60E-02 +/- 3.88E-03 L.T. 2.E-02 03/09 03/16 1.01E+04 CU. FT.
2.14E-02 +/- 4.26E-03 L.T. 9.E-03 03/16 03/23 1.OOE+04 CU. FT.
1.42E-02 +/- 3.62E-03 L.T. 3.E-02 03/23 03/30 1.00E+04 CU. FT.
1.70E-02 +/- 3.73E-03 L.T. 3.E-02 03/30 04/06 1.01E+04 CU. FT.
1.91E-02 +/- 4.17E-03 L.T. 9.E-03 04/06 04/12 8.58E+03 CU. FT.
1.85E-02 +/- 4.38E-03 L.T. 3.E-02 04/12 04/20 1.14E+04 CU. FT.
2.55E-02 +/- 4.12E-03 L.T. 2.E-02 04/20 04/27 9.99E+03 CU. FT.
1.38E-02 +/- 3.49E-03 L.T. 4.E-02 04/27 05/04 1.01E+04 CU. FT.
1.67E-02 +/- 3.78E-03 L.T. 3.E-02 05/04 05/11 9.98E+03 CU. FT.
2.19E-02 +/- 4.56E-03 L.T. 1.E-02 05/11 05/19 1.15E+04 CU. FT.
1.39E-02 +/- 3.48E-03 L.T. 2.E-02 05/19 05/25 8.71E+03 CU. FT.
1.51E-02 +/- 3.85E-03 L.T. 2.E-02 05/25 06/01 9.97E+03 CU. FT.
1.53E-02 +/- 3.72E-03 L.T. 2.E-02 06/01 06/08 1.01E+04 CU. FT.
1.29E-02 +/- 3.82E-03 L.T. 1.E-02 06/08 06/14 8.53E+03 CU. FT.
1.58E-02 +/- 4.03E-03 L.T. 2.E-02 06/14 06/22 1.15E+04 CU. FT.
1.35E-02 +/- 3.08E-03 L.T. 2.E-02 06/22 06/29 1.02E+04 CU. FT.
1.86E-02 +/- 4.03E-03 L.T. 2.E-02
VIl-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 02 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCIICU.M.)
(PCI/CU.M.)
06129 07/06 9.85E+03 CU. FT.
1.56E-02 +/- 3.99E-03 L.T. 3.E-02 07/06 07/13 1.OOE+04 CU. FT.
1.54E-02 +/- 3.74E-03 L.T. 2.E-02 07/13 07/19 8.65E+03 CU. FT.
1.42E-02 +/- 4.12E-03 L.T. 3.E-02 07/19 07/27 1.15E+04 CU. FT.
2.44E-02 +/- 3.90E-03 L.T. 2.E-02 07/27 08/03 1.00E+04 CU. FT.
2.18E-02 +/- 4.34E-03 L.T. 4.E-02 08/03 08/10 1.OOE+04 CU. FT.
1.69E-02 +/- 3.95E-03 L.T. 3.E-02 08/10 08/17 1.OOE+04 CU. FT.
1.75E-02 +/- 3.93E-03 L.T. 1.E-02 08/17 08/24 1.00E+04 CU. FT.
2.06E-02 +/- 4.13E-03 L.T. 1.E-02 08/24 08/31 1.00E+04 CU. FT.
1.29E-02 +/- 3.44E-03 L.T. 3.E-02 08/31 09/07 1.01E+04 CU. FT.
2.10E-02 +/- 4.01E-03 L.T. 1.E-02 09/07 09114 1.OOE+04 CU. FT.
1.79E-02 +/- 4.29E-03 L.T. 2.E-02 09/14 09/21 1.03E+04 CU. FT.
1.52E-02 +/- 3.75E-03 L.T. 3.E-02 09/21 09/27 7.52E+03 CU. FT.
2.68E-02 +/- 5.34E-03 L.T. 9.E-03 09/27 10/05 1.10E+04 CU. FT.
2.18E-02 +/- 4.04E-03 L.T. 4.E-02 10/05 10/13 1.15E+04 CU. FT.
1.98E-02 +/- 3.89E-03 L.T. 1.E-02 10/13 10/19 8.61E+03 CU. FT.
1.74E-02 +/- 4.08E-03 L.T. 3.E-02 10/19 10/26 1.01E+04 CU. FT.
2.58E-02 +/- 4.33E-03 L.T. 3.E-02 10/26 11/02 1.00E+04 CU. FT.
2.16E-02 +/- 4.10E-03 L.T. 2.E-02 11(02 11/09 1.OOE+04 CU. FT.
2.99E-02 +/- 4.79E-03 L.T. 3.E-02 11/09 11/16 1.00E+04 CU. FT.
2.75E-02 +/- 4.53E-03 L.T. 2.E-02 11/16 11/23 1.OOE+04 CU. FT.
2.46E-02 +/- 4.31E-03 L.T. 2.E-02 11/23 11/30 1.01E+04 CU. FT.
2.40E-02 +/- 4.29E-03 L.T. 4.E-02 11/30 12/07 1.00E+04 CU. FT.
4.13E-02 +/- 5.42E-03 L.T. 3.E-02 12/07 12/13 8.65E+03 CU. FT.
2.04E-02 +/- 5.76E-03 L.T. 2.E-02 12/13 12/21 1.13E+04 CU. FT.
2.33E-02 +/- 3.94E-03 L.T. 1.E-02 12/21 12/28 1.01E+04 CU. FT.
3.70E-02 +/- 5.32E-03 L.T. 3.E-02
VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 03 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCIICU.M.)
12/30 01/06 1.02E+04 CU. FT.
3.70E-02 +/- 5.03E-03 L.T. 2.E-02 01/06 01/13 9.73E+03 CU. FT.
4.10E-02 +/- 5.53E-03 L.T. 3.E-02 01/13 01/20 1.01E+04 CU. FT.
3.21E-02 +/- 4.70E-03 L.T. 1.E-02 01/20 01/28 1.17E+04 CU. FT.
2.11E-02 +/- 3.83E-03 L.T. 9.E-03 01/28 02/04 9.87E+03 CU. FT.
4.21E-02 +/- 5.46E-03 L.T. 1.E-02 02/04 02/11 1.01E+04 CU. FT.
4.48E-02 +/- 5.65E-03 L.T. 1.E-02 02/11 02/17 8.55E+03 CU. FT.
2.84E-02 +/- 5.06E-03 L.T. 1.E-02 w
02/17 02/24 1.04E+04 CU. FT.
2.94E-02 +/- 4.80E-03 L.T. 1.E-02 tD 02/24 03/02 9.88E+03 CU. FT.
1.66E-02 +/- 3.85E-03 L.T. 9.E-03 03/02 03/09 9.90E+03 CU. FT.
1.45E-02 +/- 3.79E-03 L.T. 2.E-02 03/09 03/16 1.01E+04 CU. FT.
1.86E-02 +/- 4.06E-03 L.T. 9.E-03 03/16 03/23 1.00E+04 CU. FT.
1.40E-02 +/- 3.61E-03 L.T. 3.E-02 03/23 03130 1.OOE+04 CU. FT.
1.38E-02 +/- 3.46E-03 L.T. 3.E-02 03/30 04/06 1.03E+04 CU. FT.
1.48E-02 +/- 3.80E-03 L.T. 9.E-03 04/06 04112 8.30E+03 CU. FT.
1.87E-02 +/- 4.50E-03 L.T. 3.E-02 04/12 04/20 1.15E+04 CU. FT.
2.20E-02 +/- 3.86E-03 L.T. 2.E-02 04/20 04127 9.97E+03 CU. FT.
1.28E-02 +/- 3.41E-03 L.T. 4.E-02 04/27 05/04 1.01E+04 CU. FT.
1.77E-02 +/- 3.86E-03 L.T. 2.E-02 05/04 05/11 9.91E+03 CU. FT.
2.19E-02 +/- 4.58E-03 L.T. 1.E-02 05(11 05/19 1.15E+04 CU. FT.
1.57E-02 +/- 3.61E-03 L.T. 2.E-02 05(19 05/25 8.76E+03 CU. FT.
1.77E-02 +/- 4.06E-03 L.T. 2.E-02 05/25 06/01 9.97E+03 CU. FT.
1.37E-02 +/- 3.59E-03 L.T. 2.E-02 06/01 06/08 1.01E+04 CU. FT.
1.54E-02 +/- 4.01E-03 L.T. 1.E-02 06(08 06/14 8.47E+03 CU. FT.
1.50E-02 +/- 3.98E-03 L.T. 2.E-02 06/14 06/22 1.16E+04 CU. FT.
1.33E-02 +/- 3.04E-03 L.T. 2.E-02 06/22 06/29 1.02E+04 CU. FT.
1.67E-02 +/- 3.89E-03 L.T. 2.E-02
Vll-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 03 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
06/29 07/06 9.85E+03 CU. FT.
1.44E-02 +/- 3.89E-03 L.T. 3.E-02 07/06 07/13 9.91E+03 CU. FT.
1.52E-02 +/- 3.75E-03 L.T. 2.E-02 07/13 07/19 8.76E+03 CU. FT.
1.57E-02 +/- 4.21E-03 L.T. 3.E-02 07/19 07/27 1.15E+04 CU. FT.
2.32E-02 +/- 3.82E-03 L.T. 2.E-02 07/27 08/03 1.00E+04 CU. FT.
2.34E-02 +/- 4.45E-03 L.T. 4.E-02 08/03 08/10 1.OOE+04 CU. FT.
1.37E-02 +/- 3.71E-03 L.T. 3.E-02 08/10 08/17 1.OOE+04 CU. FT.
2.29E-02 +/- 4.32E-03 L.T. 1.E-02 08/17 08/24 1.02E+04 CU. FT.
2.28E-02 +/- 4.23E-03 L.T. 1.E-02 08/24 08/31 9.91E+03 CU. FT.
1.49E1-02 +/- 3.63E-03 L.T. 3.E-02 08/31 09/07 1.01E+04 CU. FT.
2.40E-02 +/- 4.23E-03 L.T. 1.E-02 09/07 09/14 1.OOE+04 CU. FT.
2.08E-02 +/- 4.48E-03 L.T. 2.E-02 09/14 09/21 1.03E+04 CU. FT.
1.25E-02 +/- 3.53E-03 L.T. 3.E-02 09/21 09/27 8.52E+03 CU. FT.
2.45E-02 +/- 4.78E-03 L.T. 1.E-02 09/27 10/05 1.13E+04 CU. FT.
2.07E-02 +/- 3.90E-03 L.T. 4.E-02 10/05 10/13 1.15E+04 CU. FT.
1.74E-02 +/- 3.72E-03 L.T. 1.E-02 10/13 10/19 8.78E+03 CU. FT.
1.70E-02 +/- 4.OOE-03 L.T. 3.E-02 10/19 10/26 9.97E+03 CU. FT.
2.06E-02 +/- 3.99E-03 L.T. 3.E-02 10/26 11/02 1.01E+04 CU. FT.
1.54E-02 +/- 3.60E-03 L.T. 2.E-02 11/02 11/09 9.81E+03 CU. FT.
2.37E-02 +/- 4.44E-03 L.T. 3.E-02 11/09 11/16 1.01E+04 CU. FT.
2.27E-02 +/- 4.17E-03 L.T. 2.E-02 11/16 11/23 1.00E+04 CU. FT.
2.31E-02 +/- 4.21E-03 L.T. 2.E-02 11/23 11/30 1.02E+04 CU. FT.
2.13E-02 +/- 4.07E-03 L.T. 4.E-02 11/30 12/07 9.96E+03 CU. FT.
4.44E-02 +/- 5.60E-03 L.T. 3.E-02 12/07 12/13 8.65E+03 CU. FT.
2.33E-02 +/- 5.93E-03 L.T. 2.E-02 12/13 12/21 1.12E+04 CU. FT.
1.96E-02 +/- 3.70E-03 L.T. 1.E-02 12/21 12/28 1.01E+04 CU. FT.
3.61E-02 +/- 5.27E-03 L.T. 3.E-02
VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 04 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
12/30 01/06 1.01E+04 CU. FT.
3.83E-02 +/- 5.13E-03 L.T. 2.E-02 01/06 01/13 9.85E+03 CU. FT.
4.50E-02 +/- 5.71E-03 L.T. 3.E-02 01/13 01/20 1.01E+04 CU. FT.
3.42E-02 +/- 4.83E-03 L.T. 1.E-02 01/20 01/28 1.17E+04 CU. FT.
2.10E-02 +/- 3.82E-03 L.T. 1.E-02 01/28 02/04 9.84E+03 CU. FT.
4.44E-02 +/- 5.59E-03 L.T. 1.E-02 02/04 02/11 1.01E+04 CU. FT.
4.23E-02 +/- 5.52E-03 L.T. 2.E-02 02/11 02/17 8.60E+03 CU. FT.
2.63E-02 +/- 4.90E-03 L.T. I.E-02
,p 02/17 02/24 1.04E+04 CU. FT.
2.53E-02 +/- 4.54E-03 L.T. 1.E-02 02/24 03/02 9.89E+03 CU. FT.
1.66E-02 +/- 3.84E-03 L.T. 9.E-03 03/02 03/09 9.91E+03 CU. FT.
1.64E-02 +/- 3.94E-03 L.T. 2.E-02 03/09 03/16 1.01E+04 CU. FT.
1.92E-02 +/- 4.10E-03 L.T. 9.E-03 03/16 03/23 1.00E+04 CU. FT.
1.27E-02 +/- 3.50E-03 L.T. 3.E-02 03/23 03/30 1.02E+04 CU. FT.
1.32E-02 +/- 3.37E-03 L.T. 3.E-02 03/30 04/06 1.01E+04 CU. FT.
1.91E-02 +/- 4.17E-03 L.T. 9.E-03 04/06 04/12 8.33E+03 CU. FT.
1.60E-02 +/- 4.26E-03 L.T. 3.E-02 04/12 04/20 1.15E+04 CU. FT.
2.39E-02 +/- 3.99E-03 L.T. 2.E-02 04/20 04/27 1.00E+04 CU. FT.
1.48E-02 +/- 3.58E-03 L.T. 4.E-02 04/27 05/04 1.OOE+04 CU. FT.
2.17E-02 +/- 4.17E-03 L.T. 3.E-02 05/04 05/11 1.00E+04 CU. FT.
2.12E-02 +/- 4.51E-03 L.T. 1.E-02 05/11 05/19 1.15E+04 CU. FT.
1.35E-02 +/- 3.45E-03 L.T. 2.E-02 05/19 05/25 8.73E+03 CU. FT.
1.73E-02 +/- 4.03E-03 L.T. 2.E-02 05/25 06/01 9.96E+03 CU. FT.
1.34E-02 +/- 3.57E-03 L.T. 1.E-02 06/01 06/08 1.01E+04 CU. FT.
1.69E-02 +/- 4.12E-03 L.T. 1.E-02 06/08 06/14 8.40E+03 CU. FT.
1.90E-02 +/- 4.34E-03 L.T. 2.E-02 06/14 06/22 1.16E+04 CU. FT.
1.43E-02 +/- 3.12E-03 L.T. 2.E-02 06/22 06/29 1.02E+04 CU. FT.
2.20E-02 +/- 4.26E-03 L.T. 2.E-02
VI1-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 04 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
06/29 07/06 9.74E+03 CU. FT.
1.35E-02 +/- 3.86E-03 L.T. 3.E-02 07/06 07/13 1.00E+04 CU. FT.
1.69E-02 +/- 3.86E-03 L.T. 2.E-02 07/13 07/19 8.65E+03 CU. FT.
1.93E-02 +/- 4.53E-03 L.T. 3.E-02 07/19 07/27 1.15E+04 CU. FT.
2.48E-02 +/- 3.93E-03 L.T. 2.E-02 07/27 08/03 1.OOE+04 CU. FT.
2.10E-02 +/- 4.29E-03 L.T. 4.E-02 08/03 08/10 1.OOE+04 CU. FT.
2.15E-02 +/- 4.29E-03 L.T. 3.E-02 08/10 08/17 1.OOE+04 CU. FT.
2.21 E-02 +/- 4.27E-03 L.T. 1.E-02 08/17 08/24 1.02E+04 CU. FT.
2.07E-02 +/- 4.09E-03 L.T. 1.E-02 08/24 08/31 9.91E+03 CU. FT.
1.21E-02 +/- 3.39E-03 L.T. 3.E-02 08/31 09/07 1.01E+04 CU. FT.
2.43E-02 +/- 4.25E-03 L.T. 1.E-02 09/07 09/14 1.00E+04 CU. FT.
2.24E-02 +/- 4.59E-03 L.T. 2.E-02 09/14 09/21 1.03E+04 CU. FT.
1.80E-02 +/- 3.95E-03 L.T. 3.E-02 09/21 09/27 8.58E+03 CU. FT.
3.OOE-02 +/- 5.14E-03 L.T. 1.E-02 09/27 10/05 1.1IE+04 CU. FT.
1.76E-02 +/- 3.73E-03 L.T. 4.E-02 10/05 10/13 1.15E+04 CU. FT.
1.75E-02 +/- 3.73E-03 L.T. 1.E-02 10/13 10/19 8.58E+03 CU. FT.
1.67E-02 +/- 4.04E-03 L.T. 2.E-02 10/19 10/26 9.99E+03 CU. FT.
2.15E-02 +/- 4.05E-03 L.T. 3.E-02 10/26 11/02 1.01E+04 CU. FT.
2.04E-02 +/- 3.99E-03 L.T. 2.E-02 11/02 11/09 9.85E+03 CU. FT.
2.61E-02 +/- 4.60E-03 L.T. 3.E-02 11/09 11/16 1.02E+04 CU. FT.
2.31E-02 +/- 4.17E-03 L.T. 2.E-02 11/16 11/23 9.96E+03 CU. FT.
2.24E-02 +/- 4.17E-03 L.T. 2.E-02 11/23 11/30 1.02E+04 CU. FT.
2.28E-02 +/- 4.17E-03 L.T. 4.E-02 11/30 12/07 9.92E+03 CU. FT.
4.30E-02 +/- 5.53E-03 L.T. 3.E-02 12/07 12/13 8.66E+03 CU. FT.
2.74E-02 +/- 6.16E-03 L.T. 2.E-02 12/13 12/21 1.12E+04 CU. FT.
2.11E-02 +/- 3.81E-03 L.T. 1.E-02 12/21 12/28 1.01E+04 CU. FT.
3.61E-02 +/- 5.27E-03 L.T. 3.E-02
V11-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 05 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
12/30 01/06 1.01E+04 CU. FT.
3.67E-02 +/- 5.04E-03 L.T. 1.E-02 01/06 01/13 9.85E+03 CU. FT.
5.44E-02 +/- 6.19E-03 L.T. 2.E-02 01/13 01/20 1.01E+04 CU. FT.
3.25E-02 +/- 4.73E-03 L.T. 8.E-03 01/20 01/28 1.17E+04 CU. FT.
2.11E-02 +/- 3.83E-03 L.T. 5.E-03 01/28 02/04 9.88E+03 CU. FT.
4.27E-02 +/- 5.48E-03 L.T. 5.E-03 02/04 02/11 1.01E+04 CU. FT.
3.90E-02 +/- 5.34E-03 L.T. 3.E-02 02/11 02/17 8.59E+03 CU. FT.
2.70E-02 +/- 4.96E-03 L.T. I.E-02 02/17 02/24 1.04E+04 CU. FT.
3.22E-02 +/- 4.96E-03 L.T. 5.E-03 02/24 03/02 9.87E+03 CU. FT.
1.59E-02 +/- 3.79E-03 L.T. 5.E-03 03/02 03/09 9.91E+03 CU. FT.
1.82E-02 +/- 4.08E-03 L.T. 1.E-02 03/09 03/16 1.01E+04 CU. FT.
1.95E-02 +/- 4.12E-03 L.T. 4.E-03 03/16 03/23 1.OOE+04 CU. FT.
1.33E-02 +/- 3.55E-03 L.T. 1.E-02 03/23 03/30 1.02E+04 CU. FT.
1.38E-02 +/- 3.42E-03 L.T. 1.E-02 03130 04(06 1.02E+04 CU. FT.
2.17E-02 +/- 4.32E-03 L.T. 7.E-03 04/06 04/12 8.30E+03 CU. FT.
2.03E-02 +/- 4.62E-03 L.T. 2.E-02 04/12 04/20 1.15E+04 CU. FT.
2.73E-02 +/- 4.20E-03 L.T. 1.E-02 04/20 04(27 1.00E+04 CU. FT.
1.52E-02 +/- 3.61E-03 L.T. 3.E-02 04/27 05/04 1.00E+04 CU. FT.
1.84E-02 +/- 3.93E-03 L.T. 1.E-02 05/04 05/11 1.00E+04 CU. FT.
2.48E-02 +/- 4.74E-03 L.T. 1.E-02 05/11 05/19 1.15E+04 CU. FT.
1.42E-02 +/- 3.49E-03 L.T. 9.E-03 05/19 05/25 8.73E+03 CU. FT.
1.88E-02 +/- 4.16E-03 L.T. 1.E-02 05125 06/01 9.96E+03 CU. FT.
1.04E-02 +/- 3.31E-03 L.T. 1.E-02 06/01 06/08 1.01E+04 CU. FT.
1.55E-02 +/- 4.02E-03 L.T. 9.E-03 06/08 06/14 8.1OE+03 CU. FT.
1.74E-02 +/- 4.31E-03 L.T. 1.E-02 06/14 06/22 1.16E+04 CU. FT.
1.66E-02 +/- 3.31E-03 L.T. 9.E-03 06/22 06/29 1.02E+04 CU. FT.
2.50E-02 +/- 4.47E-03 L.T. 1.E-02
VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 05 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
06/29 07/06 9.74E+03 CU. FT.
1.64E-02 +/- 4.08E-03 L.T. 2.E-02 07/06 07/13 1.00E+04 CU. FT.
1.36E-02 +/- 3.60E-03 L.T. 1.E-02 07/13 07/19 8.65E+03 CU. FT.
1.74E-02 +/- 4.38E-03 L.T. 2.E-02 07/19 07/27 1.15E+04 CU. FT.
2.70E-02 +/- 4.07E-03 L.T. 9.E-03 07/27 08/03 1.00E+04 CU. FT.
2.31E-02 +/- 4.43E-03 L.T. 3.E-02 08/03 08/10 9.99E+03 CU. FT.
1.90E-02 +/- 4.11E-03 L.T. 2.E-02 08/10 08/17 1.00E+04 CU. FT.
2.29E-02 +/- 4.32E-03 L.T. 1.E-02 08/17 08/24 1.02E+04 CU. FT.
2.19E-02 +/- 4.17E-03 L.T. 9.E-03 08/24 08/31 9.91E+03 CU. FT.
1.39E-02 +/- 3.55E-03 L.T. 2.E-02 08/31 09/07 1.01E+04 CU. FT.
2.99E-02 +/- 4.61E-03 L.T. 9.E-03 09/07 09/14 1.OOE+04 CU. FT.
2.39E-02 +/- 4.69E-03 L.T. 1.E-02 09/14 09/21 1.03E+04 CU. FT.
1.22E-02 +/- 3.51E-03 L.T. 2.E-02 09/21 09/27 8.58E+03 CU. FT.
2.79E-02 +/- 5.OOE-03 L.T. 1.E-02 09/27 10/05 1.13E+04 CU. FT.
2.02E-02 +/- 3.87E-03 L.T. 2.E-02 10/05 10/13 1.15E+04 CU. FT.
1.88E-02 +/- 3.82E-03 L.T. 9.E-03 10/13 10/19 8.72E+03 CU. FT.
2.10E-02 +/- 4.35E-03 L.T. 3.E-02 10/19 10/26 9.98E+03 CU. FT.
2.27E-02 +/- 4.14E-03 L.T. 1.E-02 10/26 11/02 1.01E+04 CU. FT.
1.67E-02 +/- 3.71E-03 L.T. 1.E-02 11/02 11/09 9.85E+03 CU. FT.
2.25E-02 +/- 4.35E-03 L.T. 1.E-02 11/09 11/16 1.02E+04 CU. FT.
2.57E-02 +/- 4.35E-03 L.T. 2.E-02 11/16 11/23 9.96E+03 CU. FT.
2.90E-02 +/- 4.61E-03 L.T. 9.E-03 11/23 11/30 1.02E+04 CU. FT.
2.25E-02 +/- 4.15E-03 L.T. 2.E-02 11/30 12/07 9.92E+03 CU. FT.
3.85E-02 +/- 5.29E-03 L.T. 2.E-02 12/07 12/13 8.66E+03 CU. FT.
2.76E-02 +/- 6.17E-03 L.T. 9.E-03 12/13 12/21 1.12E+04 CU. FT.
2.19E-02 +/- 3.87E-03 L.T. 9.E-03 12/21 12/28 1.01E+04 CU. FT.
4.02E-02 +/- 5.50E-03 L.T. 2.E-02
Vll-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 06 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
12/30 01/06 1.02E+04 CU. FT.
3.98E-02 +/- 5.19E-03 L.T. 4.E-02 01/06 01/13 9.81E+03 CU. FT.
4.86E-02 +/- 5.91E-03 L.T. 4.E-02 01/13 01/20 1.01E+04 CU. FT.
3.33E-02 +/- 4.78E-03 L.T. 9.E-03 01/20 01/28 1.17E+04 CU. FT.
2.43E-02 +/- 4.03E-03 L.T. 8.E-03 01/28 02/04 9.84E+03 CU. FT.
3.88E-02 +/- 5.28E-03 L.T. 1.E-02 02/04 02/11 1.01E+04 CU. FT.
4.32E-02 +/- 5.57E-03 L.T. 2.E-02 02/11 02/17 8.59E+03 CU. FT.
2.79E-02 +/- 5.02E-03 L.T. 1.E-02 02/17 02/24 1.04E+04 CU. FT.
2.97E-02 +/- 4.82E-03 L.T. 1.E-02 02/24 03/02 9.89E+03 CU. FT.
1.65E-02 +/- 3.83E-03 L.T. 1.E-02 03/02 03/09 9.91E+03 CU. FT.
1.79E-02 +/- 4.06E-03 L.T. 2.E-02 03/09 03/16 1.01E+04 CU. FT.
1.91E-02 +/- 4.09E-03 L.T. 1.E-02 03/16 03/23 1.OOE+04 CU. FT.
1.39E-02 +/- 3.60E-03 L.T. 3.E-02 03/23 03/30 1.02E+04 CU. FT.
1.35E-02 +/- 3.40E-03 L.T. 3.E-02 03/30 04/06 1.02E+04 CU. FT.
2.09E-02 +/- 4.27E-03 L.T. 1.E-02 04/06 04/12 8.30E+03 CU. FT.
1.68E-02 +/- 4.34E-03 L.T. 4.E-02 04/12 04/20 1.15E+04 CU. FT.
2.77E-02 +/- 4.23E-03 L.T. 2.E-02 04/20 04/27 1.OOE+04 CU. FT.
1.18E-02 +/- 3.32E-03 L.T. 3.E-02 04/27 05/04 1.OOE+04 CU. FT.
1.94E-02 +/- 4.01E-03 L.T. 2.E-02 05/04 05/11 1.00E+04 CU. FT.
2.06E-02 +/- 4.47E-03 L.T. 1.E-02 05/11 05/19 1.15E+04 CU. FT.
1.45E-02 +/- 3.52E-03 L.T. 2.E-02 05/19 05/25 8.73E+03 CU. FT.
1.90E-02 +/- 4.18E-03 L.T. 2.E-02 05/25 06/01 9.96E+03 CU. FT.
1.23E-02 +/- 3.48E-03 L.T. 2.E-02 06/01 06/08 1.01E+04 CU. FT.
1.46E-02 +/- 3.96E-03 L.T. 2.E-02 06/08 06/14 8.1OE+03 CU. FT.
1.48E-02 +/- 4.08E-03 L.T. 7.E-03 06/14 06/22 1.16E+04 CU. FT.
1.38E-02 +/- 3.08E-03 L.T. 2.E-02 06/22 06/29 1.02E+04 CU. FT.
2.45E-02 +/- 4.43E-03 L.T. 1.E-02
VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 06 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
06/29 07/06 9.74E+03 CU. FT.
1.73E-02 +/- 4.14E-03 L.T. 2.E-02 07/06 07/13 1.OOE+04 CU. FT.
1.55E-02 +/- 3.76E-03 L.T. 2.E-02 07/13 07/19 8.65E+03 CU. FT.
1.74E-02 +/- 4.38E-03 L.T. 2.E-02 07/19 07/27 1.15E+04 CU. FT.
2.66E-02 +/- 4.04E-03 L.T. 3.E-02 07/27 08/03 1.00E+04 CU. FT.
2.20E-02 +/- 4.36E-03 L.T. 3.E-02 08/03 08/10 9.61E+03 CU. FT.
1.69E-02 +/- 4.06E-03 L.T. 3.E-02 08/10 08/17 1.00E+04 CU. FT.
2.48E-02 +/- 4.45E-03 L.T. 1.E-02
,p 08/17 08/24 1.02E+04 CU. FT.
2.03E-02 +/- 4.06E-03 L.T. 2.E-02 tn 08/24 08/31 9.72E+03 CU. FT.
1.71E-02 +/- 3.85E-03 L.T. 2.E-02 08/31 09(07 9.99E+03 CU. FT.
2.78E-02 +/- 4.51E-03 L.T. 8.E-03 09/07 09/14 1.00E+04 CU. FT.
2.36E-02 +/- 4.67E-03 L.T. 2.E-02 09/14 09/21 1.03E+04 CU. FT.
1.74E-02 +/- 3.91E-03 L.T. 3.E-02 09/21 09/27 8.34E+03 CU. FT.
3.11 E-02 +/- 5.30E-03 L.T. 2.E-02 09/27 10/05 1.13E+04 CU. FT.
2.20E-02 +/- 3.99E-03 L.T. 3.E-02 10/05 10/13 1.15E+04 CU. FT.
2.24E-02 +/- 4.05E-03 L.T. 2.E-02 10/13 10/19 8.72E+03 CU. FT.
1.92E-02 +/- 4.20E-03 L.T. 3.E-02 10/19 10/26 9.97E+03 CU. FT.
2.86E-02 +/- 4.55E-03 L.T. 3.E-02 10/26 11/02 1.01E+04 CU. FT.
1.79E-02 +/- 3.80E-03 L.T. 2.E-02 11(02 11(09 9.85E+03 CU. FT.
2.88E-02 +/- 4.77E-03 L.T. 2.E-02 11/09 11/16 1.02E+04 CU. FT.
2.06E-02 +/- 4.OOE-03 L.T. 2.E-02 11/16 11/23 9.96E+03 CU. FT.
2.41E-02 +/- 4.29E-03 L.T. 2.E-02 11/23 11/30 1.02E+04 CU. FT.
2.15E-02 +/- 4.08E-03 L.T. 3.E-02 11/30 12/07 9.92E+03 CU. FT.
4.28E-02 +/- 5.53E-03 L.T. 2.E-02 12(07 12/13 8.66E+03 CU. FT.
2.97E-02 +/- 6.29E-03 L.T. 1.E-02 12/13 12/21 1.13E+04 CU. FT.
2.32E-02 +/- 3.93E-03 L.T. 1.E-02 12/21 12/28 1.01E+04 CU. FT.
3.22E-02 +/- 5.05E-03 L.T. 4.E-02
Vll-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 07 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
12/30 01/06 1.01E+04 CU. FT.
3.89E-02 +/- 5.17E-03 L.T. 4.E-02 01/06 01/13 9.97E+03 CU. FT.
4.72E-02 +/- 5.79E-03 L.T. 4.E-02 01/13 01/20 1.01E+04 CU. FT.
3.21E-02 +/- 4.70E-03 L.T. 9.E-03 01/20 01/28 1.15E+04 CU. FT.
2.32E-02 +/- 4.OOE-03 L.T. 8.E-03 01/28 02/04 9.93E+03 CU. FT.
4.44E-02 +/- 5.56E-03 L.T. 1.E-02 02/04 02/11 1.01E+04 CU. FT.
3.97E-02 +/- 5.38E-03 L.T. 3.E-02 02/11 02/17 8.68E+03 CU. FT.
2.20E-02 +/- 4.56E-03 L.T. I.E-02 02/17 02/24 1.04E+04 CU. FT.
2.87E-02 +/- 4.75E-03 L.T. 1.E-02 o
02/24 03/02 9.75E+03 CU. FT.
1.47E-02 +/- 3.73E-03 L.T. 1.E-02 03/02 03/09 1.00E+04 CU. FT.
1.40E-02 +/- 3.73E-03 L.T. 2.E-02 03/09 03/16 1.01E+04 CU. FT.
1.52E-02 +/- 3.80E-03 L.T. 1.E-02 03/16 03/23 1.00E+04 CU. FT.
1.72E-02 +/- 3.86E-03 L.T. 3.E-02 03/23 03/30 1.00E+04 CU. FT.
1.44E-02 +/- 3.51E-03 L.T. 3.E-02 03/30 04/06 1.01E+04 CU. FT.
1.61E-02 +/- 3.96E-03 L.T. 1.E-02 04/06 04/12 8.54E+03 CU. FT.
1.84E-02 +/- 4.38E-03 L.T. 3.E-02 04/12 04/20 1.14E+04 CU. FT.
1.40E-02 +/- 3.30E-03 L.T. 2.E-02 04/20 04/27 9.99E+03 CU. FT.
1.38E-02 +/- 3.49E-03 L.T. 3.E-02 04/27 05/04 1.01E+04 CU. FT.
2.01E-02 +/- 4.03E-03 L.T. 2.E-02 05/04 05/11 9.98E+03 CU. FT.
2.42E-02 +/- 4.71E-03 L.T. 1.E-02 05/11 05/19 1.15E+04 CU. FT.
1.40E-02 +/- 3.49E-03 L.T. 2.E-02 05/19 05/25 8.71E+03 CU. FT.
2.01 E-02 +/- 4.27E-03 L.T. 2.E-02 05/25 06/01 9.97E+03 CU. FT.
8.76E-03 +/- 3.16E-03 L.T. 2.E-02 06/01 06/08 1.01E+04 CU. FT.
1.60E-02 +/- 4.06E-03 L.T. 2.E-02 06/08 06/14 8.53E+03 CU. FT.
1.53E-02 +/- 3.99E-03 L.T. 1.E-02 06/14 06/22 1.15E+04 CU. FT.
1.79E-02 +/- 3.42E-03 L.T. 2.E-02 06/22 06/29 1.02E+04 CU. FT.
1.16E-02 +/- 3.48E-03 L.T. 1.E-02
vl-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 07 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCIICU.M.)
06/29 07/06 9.85E+03 CU. FT.
1.58E-02 +/- 4.00E-03 L.T. 2.E-02 07/06 07/13 1.00E+04 CU. FT.
1.48E-02 +/- 3.70E-03 L.T. 2.E-02 07/13 07/19 8.65E+03 CU. FT.
1.98E-02 +/- 4.56E-03 L.T. 2.E-02 07/19 07/27 1.15E+04 CU. FT.
2.26E-02 +/- 3.78E-03 L.T. 3.E-02 07/27 08/03 1.OOE+04 CU. FT.
2.12E-02 +/- 4.30E-03 L.T. 3.E-02 08/03 08/10 9.91E+03 CU. FT.
1.46E-02 +/- 3.80E-03 L.T. 3.E-02 08/10 08/17 1.OOE+04 CU. FT.
2.03E-02 +/- 4.14E-03 L.T. 1.E-02 08/17 08/24 1.00E+04 CU. FT.
2.32E-02 +/- 4.42E-03 L.T. 2.E-02 08/24 08/31 1.OOE+04 CU. FT.
1.69E-02 +/- 3.77E-03 L.T. 3.E-02 08/31 09/07 1.01E+04 CU. FT.
2.40E-02 +/- 4.23E-03 L.T. 1.E-02 09/07 09/14 1.OOE+04 CU. FT.
7.32E-03 +/- 3.47E-03 L.T. 2.E-02 09/14 09/21 1.03E+04 CU. FT.
1.47E-02 +/- 3.70E-03 L.T. 3.E-02 09/21 09/27 8.40E+03 CU. FT.
1.48E-02 +/- 4.05E-03 L.T. 2.E-02 09/27 10/05 1.14E+04 CU. FT.
1.13E-02 +/- 3.19E-03 L.T. 3.E-02 10/05 10/13 1.1 5E+04 CU. FT.
2.33E-02 +/- 4.11E-03 L.T. 2.E-02 10/13 10/19 8.64E+03 CU. FT.
8.22E-03 +/- 3.21E-03 L.T. 3.E-02 10/19 10/26 1.01E+04 CU. FT.
2.39E-02 +/- 4.20E-03 L.T. 3.E-02 10/26 11/02 1.OOE+04 CU. FT.
2.28E-02 +/- 4.19E-03 L.T. 2.E-02 11/02 11/09 1.OOE+04 CU. FT.
2.74E-02 +/- 4.63E-03 L.T. 2.E-02 11/09 11/16 1.OOE+04 CU. FT.
2.81E-02 +/- 4.57E-03 L.T. 2.E-02 11/16 11/23 1.OOE+04 CU. FT.
2.55E-02 +/- 4.37E-03 L.T. 2.E-02 11/23 11/30 1.01 E+04 CU. FT.
2.10E-02 +/- 4.07E-03 L.T. 3.E-02 11/30 12/07 1.OOE+04 CU. FT.
4.63E-02 +/- 5.69E-03 L.T. 2.E-02 12/07 12/13 8.65E+03 CU. FT.
2.62E-02 +/- 6.10E-03 L.T. 1.E-02 12/13 12/21 1.13E+04 CU. FT.
1.47E-02 +/- 3.31E-03 L.T. 1.E-02 12/21 12/28 1.01 E+04 CU. FT.
3.82E-02 +/- 5.39E-03 L.T. 4.E-02
Vll-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 08 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
12/30 01/06 1.OOE+04 CU. FT.
4.93E-02 +/- 5.76E-03 L.T. 4.E-02 01/06 01/13 9.99E+03 CU. FT.
4.29E-02 +/- 5.55E-03 L.T. 4.E-02 01/13 01/20 1.01E+04 CU. FT.
3.03E-02 +/- 4.59E-03 L.T. 9.E-03 01/20 01/28 1.16E+04 CU. FT.
1.99E-02 +/- 3.77E-03 L.T. 8.E-03 01/28 02/04 9.90E+03 CU. FT.
4.19E-02 +/- 5.43E-03 L.T. 1.E-02 02/04 02/11 1.00E+04 CU. FT.
4.19E-02 +/- 5.53E-03 L.T. 2.E-02 02/11 02/17 8.68E+03 CU. FT.
3.OOE-02 +/- 5.13E-03 L.T. 1.E-02 02/17 02/24 1.04E+04 CU. FT.
2.92E-02 +/- 4.78E-03 L.T. 1.E-02 tn 02/24 03/02 9.76E+03 CU. FT.
1.39E-02 +/- 3.66E-03 L.T. 1.E-02 03/02 03/09 1.00E+04 CU. FT.
1.58E-02 +/- 3.87E-03 L.T. 2.E-02 03(09 03/16 1.01E+04 CU. FT.
2.09E-02 +/- 4.21E-03 L.T. 1.E-02 03/16 03/23 1.00E+04 CU. FT.
1.58E-02 +/- 3.75E-03 L.T. 3.E-02 03/23 03/30 1.OOE+04 CU. FT.
1.33E-02 +/- 3.43E-03 L.T. 3.E-02 03/30 04/06 1.03E+04 CU. FT.
2.02E-02 +/- 4.19E-03 L.T. 1.E-02 04/06 04/12 8.35E+03 CU. FT.
1.75E-02 +/- 4.38E-03 L.T. 4.E-02 04/12 04/20 1.14E+04 CU. FT.
2.63E-02 +/- 4.17E-03 L.T. 2.E-02 04/20 04/27 1.OOE+04 CU. FT.
1.24E-02 +/- 3.37E-03 L.T. 3.E-02 04/27 05/04 1.01E+04 CU. FT.
1.69E-02 +/- 3.79E-03 L.T. 2.E-02 05/04 05/11 9.99E+03 CU. FT.
2.12E-02 +/- 4.52E-03 L.T. 1.E-02 05/11 05/19 1.15E+04 CU. FT.
1.55E-02 +/- 3.59E-03 L.T. 2.E-02 05/19 05/25 8.76E+03 CU. FT.
1.84E-02 +/- 4.12E-03 L.T. 2.E-02 05/25 06101 9.96E+03 CU. FT.
9.06E-03 +/- 3.19E-03 L.T. 2.E-02 06/01 06/08 1.01E+04 CU. FT.
1.55E-02 +/- 4.02E-03 L.T. 2.E-02 06/08 06/14 8.55E+03 CU. FT.
1.51E-02 +/- 3.96E-03 L.T. 1.E-02 06/14 06/22 1.15E+04 CU. FT.
1.30E-02 +/- 3.03E-03 L.T. 2.E-02 06/22 06/29 1.03E+04 CU. FT.
1.91E-02 +/- 4.04E-03 L.T. 1.E-02
VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 08 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
06/29 07/06 9.81 E+03 CU. FT.
1.37E-02 +/- 3.85E-03 L.T. 2.E-02 07/06 07/13 1.00E+04 CU. FT.
1.35E-02 +/- 3.59E-03 L.T. 2.E-02 07/13 07/19 8.71E+03 CU. FT.
1.78E-02 +/- 4.39E-03 L.T. 2.E-02 07/19 07/27 1.15E+04 CU. FT.
2.25E-02 +/- 3.77E-03 L.T. 3.E-02 07/27 08/03 1.00E+04 CU. FT.
2.15E-02 +/- 4.32E-03 L.T. 3.E-02 08103 08/10 1.OOE+04 CU. FT.
1.96E-02 +/- 4.15E-03 L.T. 3.E-02 08/10 08/17 1.OOE+04 CU. FT.
1.70E-02 +/- 3.89E-03 L.T. 1.E-02 08/17 08/24 1.OOE+04 CU. FT.
1.70E-02 +/- 3.87E-03 L.T. 2.E-02 08/24 08/31 1.00E+04 CU. FT.
1.24E-02 +/- 3.40E-03 L.T. 3.E-02 08/31 09/07 1.01E+04 CU. FT.
1.96E-02 +/- 3.91E-03 L.T. 1.E-02 09/07 09/14 1.OOE+04 CU. FT.
1.14E-02 +/- 3.80E-03 L.T. 2.E-02 09/14 09/21 1.03E+04 CU. FT.
1.55E-02 +/- 3.77E-03 L.T. 3.E-02 09/21 09/27 8.58E+03 CU. FT.
2.76E-02 +/- 4.97E-03 L.T. 2.E-02 09/27 10/05 1.13E+04 CU. FT.
2.20E-02 +/- 3.99E-03 L.T. 3.E-02 10/05 10/13 1.15E+04 CU. FT.
1.89E-02 +/- 3.83E-03 L.T. 2.E-02 10/13 10/19 8.72E+03 CU. FT.
1.58E-02 +/- 3.91E-03 L.T. 3.E-02 10/19 10/26 1.01 E+04 CU. FT.
2.24E-02 +/- 4.09E-03 L.T. 3.E-02 10/26 11/02 1.OOE+04 CU. FT.
2.01E-02 +/- 3.99E-03 L.T. 2.E-02 11/02 11/09 9.97E+03 CU. FT.
2.70E-02 +/- 4.62E-03 L.T. 2.E-02 11/09 11/16 1.01E+04 CU. FT.
2.15E-02 +/- 4.09E-03 L.T. 2.E-02 11/16 11/23 1.OOE+04 CU. FT.
2.52E-02 +/- 4.35E-03 L.T. 2.E-02 11/23 11/30 1.01E+04 CU. FT.
1.85E-02 +/- 3.89E-03 L.T. 3.E-02 11/30 12/07 1.01 E+04 CU. FT.
3.96E-02 +/- 5.29E-03 L.T. 2.E-02 12/07 12/13 8.65E+03 CU. FT.
2.61E-02 +/- 6.09E-03 L.T. 1.E-02 12/13 12/21 1.13E+04 CU. FT.
2.OOE-02 +/- 3.71E-03 L.T. 1.E-02 12/21 12/28 1.01E+04 CU. FT.
3.53E-02 +/- 5.23E-03 L.T. 4.E-02
vil-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 09 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
12/30 01/06 1.01E+04 CU. FT.
5.97E-02 +/- 6.25E-03 L.T. 4.E-02 01/06 01/13 9.86E+03 CU. FT.
4.57E-02 +/- 5.75E-03 L.T. 4.E-02 01/13 01/20 1.01E+04 CU. FT.
3.83E-02 +/- 5.08E-03 L.T. 9.E-03 01/20 01/28 1.16E+04 CU. FT.
2.49E-02 +/- 4.09E-03 L.T. 8.E-03 01/28 02/04 9.91 E+03 CU. FT.
4.48E-02 +/- 5.59E-03 L.T. 1.E-02 02/04 02/11 1.00E+04 CU. FT.
4.63E-02 +/- 5.76E-03 L.T. 2.E-02 02/11 02/17 8.68E+03 CU. FT.
3.15E-02 +/- 5.23E-03 L.T. 1.E-02
- t.
02/17 02/24 1.04E+04 CU. FT.
2.93E-02 +/- 4.79E-03 L.T. 1.E-02 02/24 03/02 9.79E+03 CU. FT.
1.35E-02 +/- 3.61E-03 L.T. 1.E-02 03/02 03/09 9.98E+03 CU. FT.
1.80E-02 +/- 4.04E-03 L.T. 2.E-02 03/09 03/16 1.01E+04 CU. FT.
2.OOE-02 +/- 4.15E-03 L.T. 1.E-02 03/16 03/23 1.OOE+04 CU. FT.
1.69E-02 +/- 3.84E-03 L.T. 3.E-02 03/23 03/30 1.01E+04 CU. FT.
1.16E-02 +/- 3.25E-03 L.T. 3.E-02 03/30 04/06 1.03E+04 CU. FT.
2.23E-02 +/- 4.34E-03 L.T. 1.E-02 04/06 04/12 8.34E+03 CU. FT.
1.90E-02 +/- 4.50E-03 L.T. 4.E-02 04/12 04/20 1.15E+04 CU. FT.
2.87E-02 +/- 4.29E-03 L.T. 2.E-02 04/20 04/27 9.97E+03 CU. FT.
1.54E-02 +/- 3.64E-03 L.T. 3.E-02 04/27 05/04 1.01E+04 CU. FT.
1.94E-02 +/- 3.98E-03 L.T. 2.E-02 05/04 05/11 9.97E+03 CU. FT.
2.10E-02 +/- 4.50E-03 L.T. 7.E-03 05/11 05/19 1.15E+04 CU. FT.
1.64E-02 +/- 3.66E-03 L.T. 2.E-02 05/19 05/25 8.73E+03 CU. FT.
2.16E-02 +/- 4.38E-03 L.T. 2.E-02 05/25 06/01 9.96E+03 CU. FT.
1.43E-02 +/- 3.64E-03 L.T. 2.E-02 06/01 06/08 1.01E+04 CU. FT.
1.66E-02 +/- 4.10E-03 L.T. 2.E-02 06/08 06/14 8.53E+03 CU. FT.
1.46E-02 +/- 3.93E-03 L.T. 1.E-02 06/14 06/22 1.15E+04 CU. FT.
1.45E-02 +/- 3.16E-03 L.T. 2.E-02 06/22 06/29 1.02E+04 CU. FT.
2.09E-02 +/- 4.19E-03 L.T. 1.E-02
VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 09 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
06/29 07106 9.80E+03 CU. FT.
1.31E-02 +/- 3.81E-03 L.T. 2.E-02 07/06 07/13 9.99E+03 CU. FT.
1.75E-02 +/- 3.91E-03 L.T. 2.E-02 07/13 07/19 8.70E+03 CU. FT.
1.92E-02 +/- 4.50E-03 L.T. 2.E-02 07/19 07/27 1.15E+04 CU. FT.
2.39E-02 +/- 3.87E-03 L.T. 3.E-02 07/27 08/03 1.OOE+04 CU. FT.
2.60E-02 +/- 4.62E-03 L.T. 3.E-02 08/03 08/10 1.OOE+04 CU. FT.
1.51E-02 +/- 3.81E-03 L.T. 3.E-02 08/10 08/17 1.OOE+04 CU. FT.
1.82E-02 +/- 3.99E-03 L.T. 1.E-02 U1 08/17 08/24 1.OOE+04 CU. FT.
2.28E-02 +/- 4.29E-03 L.T. 2.E-02 I
08/24 08/31 1.00E+04 CU. FT.
1.91E-02 +/- 3.94E-03 L.T. 3.E-02 08131 09107 1.01E+04 CU. FT.
2.77E-02 +/- 4.47E-03 L.T. 1.E-02 09107 09(14 1.01E+04 CU. FT.
2.06E-02 +/- 4.44E-03 L.T. 2.E-02 09/14 09(21 1.03E+04 CU. FT.
1.68E-02 +/- 3.87E-03 L.T. 3.E-02 09/21 09/27 7.45E+03 CU. FT.
2.36E-02 +/- 5.13E-03 L.T. 2.E-02 09/27 10/05 1.1IE+04 CU. FT.
2.44E-02 +/- 4.19E-03 L.T. 3.E-02 10(05 10/13 1.15E+04 CU. FT.
2.11E-02 +/- 3.97E-03 L.T. 2.E-02 10/13 10/19 8.71E+03 CU. FT.
1.27E-02 +/- 3.64E-03 L.T. 3.E-02 10/19 10/26 1.01 E+04 CU. FT.
2.29E-02 +/- 4.12E-03 L.T. 3.E-02 10/26 11(02 1.OOE+04 CU. FT.
1.95E-02 +/- 3.95E-03 L.T. 2.E-02 11/02 11/09 9.96E+03 CU. FT.
2.36E-02 +/- 4.40E-03 L.T. 2.E-02 11(09 11116 1.01E+04 CU. FT.
2.55E-02 +/- 4.37E-03 L.T. 2.E-02 11/16 11/23 1.OOE+04 CU. FT.
1.89E-02 +/- 3.90E-03 L.T. 2.E-02 11/23 11/30 1.02E+04 CU. FT.
2.13E-02 +/- 4.07E-03 L.T. 3.E-02 11/30 12/07 9.91E+03 CU. FT.
3.72E-02 +/- 5.22E-03 L.T. 2.E-02 12/07 12/13 8.65E+03 CU. FT.
2.49E-02 +/- 6.02E-03 L.T. 1.E-02 12/13 12/21 1.13E+04 CU. FT.
2.25E-02 +/- 3.88E-03 L.T. 1.E-02 12/21 12/28 1.01E+04 CU. FT.
3.71E-02 +/- 5.33E-03 L.T. 3.E-02
vlI-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 10 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
12/30 01/06 1.01E+04 CU. FT.
5.50E-02 +/- 6.02E-03 L.T. 3.E-02 01/06 01/13 9.96E+03 CU. FT.
3.90E-02 +/- 5.35E-03 L.T. 3.E-02 01/13 01/20 1.01E+04 CU. FT.
3.55E-02 +/- 4.91E-03 L.T. 7.E-03 01/20 01/28 1.16E+04 CU. FT.
2.31E-02 +/- 3.98E-03 L.T. 5.E-03 01/28 02/04 9.92E+03 CU. FT.
3.46E-02 +/- 5.01E-03 L.T. 6.E-03 02/04 02/11 1.01E+04 CU. FT.
3.63E-02 +/- 5.19E-03 L.T. 2.E-02 02/11 02/17 8.68E+03 CU. FT.
2.44E-02 +/- 4.74E-03 L.T. 1.E-02 02/17 02/24 1.04E+04 CU. FT.
2.71E-02 +/- 4.66E-03 L.T. 8.E-03 02/24 03/02 9.75E+03 CU. FT.
1.55E-02 +/- 3.79E-03 L.T. 7.E-03 03/02 03/09 9.99E+03 CU. FT.
1.63E-02 +/- 3.91E-03 L.T. 1.E-02 03/09 03/16 1.01E+04 CU. FT.
1.39E-02 +/- 3.69E-03 L.T. 8.E-03 03/16 03/23 1.OOE+04 CU. FT.
1.45E-02 +/- 3.65E-03 L.T. 2.E-02 03/23 03/30 1.OOE+04 CU. FT.
1.32E-02 +/- 3.411E-03 L.T. 2.E-02 03/30 04/06 1.01E+04 CU. FT.
1.49E-02 +/- 3.87E-03 L.T. 7.E-03 04/06 04/12 8.67E+03 CU. FT.
1.86E-02 +/- 4.36E-03 L.T. 2.E-02 04/12 04/20 1.13E+04 CU. FT.
2.41E-02 +/- 4.04E-03 L.T. 1.E-02 04/20 04/27 9.99E+03 CU. FT.
1.24E-02 +/- 3.38E-03 L.T. 2.E-02 04/27 05/04 1.01E+04 CU. FT.
1.98E-02 +/- 4.01E-03 L.T. 1.E-02 05/04 05/11 9.99E+03 CU. FT.
2.47E-02 +/- 4.74E-03 L.T. 6.E-03 05/11 05/19 1.15E+04 CU. FT.
1.31E-02 +/- 3.42E-03 L.T. 1.E-02 05/19 05/25 8.71E+03 CU. FT.
2.01E-02 +/- 4.27E-03 L.T. 1.E-02 05/25 06/01 1.OOE+04 CU. FT.
1.33E-02 +/- 3.55E-03 L.T. 2.E-02 06/01 06/08 1.01E+04 CU. FT.
1.63E-02 +/- 4.08E-03 L.T. 9.E-03 06/08 06/14 8.55E+03 CU. FT.
1.42E-02 +/- 3.89E-03 L.T. 1.E-02 06/14 06/22 1.15E+04 CU. FT.
1.36E-02 +/- 3.09E-03 L.T. 1.E-02 06/22 06/29 1.02E+04 CU. FT.
1.52E-02 +/- 3.77E-03 L.T. 1.E-02
VII-1 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE AIR PARTICULATE & CHARCOAL FILTERS STATION NUMBER 10 COLL.
TIME AP FILTER CHARCOAL FILTER START STOP SAMPLE GROSS BETA 1-131 DATE DATE VOLUME UNITS (PCI/CU.M.)
(PCI/CU.M.)
06/29 07/06 9.87E+03 CU. FT.
8.40E-03 +/- 3.39E-03 L.T. 1.E-02 07/06 07/13 1.03E+04 CU. FT.
1.35E-02 +/- 3.52E-03 L.T. 1.E-02 07/13 07/19 8.39E+03 CU. FT.
1.92E-02 +/- 4.61E-03 L.T. 2.E-02 07/19 07/27 1.15E+04 CU. FT.
2.08E-02 +/- 3.66E-03 L.T. 2.E-02 07/27 08/03 1.OOE+04 CU. FT.
2.09E-02 +/- 4.28E-03 L.T. 2.E-02 08/03 08/10 1.00E+04 CU. FT.
1.42E-02 +/- 3.74E-03 L.T. 1.E-02 08/10 08/17 1.OOE+04 CU. FT.
1.63E-02 +/- 3.84E-03 L.T. 8.E-03 08/17 08/24 1.00E+04 CU. FT.
1.54E-02 +/- 3.74E-03 L.T. 1.E-02 08/24 08/31 1.00E+04 CU. FT.
1.51E-02 +/- 3.62E-03 L.T. 3.E-02 08/31 09/07 1.01E+04 CU. FT.
2.04E-02 +/- 3.96E-03 L.T. 1.E-02 09/07 09/14 1.01E+04 CU. FT.
1.51E-02 +/- 4.06E-03 L.T. 1.E-02 09/14 09/21 1.03E+04 CU. FT.
1.35E-02 +/- 3.61E-03 L.T. 3.E-02 09/21 09/27 8.41 E+03 CU. FT.
1.92E-02 +/- 4.41E-03 L.T. 2.E-02 09/27 10/05 1.14E+04 CU. FT.
1.91E-02 +/- 3.77E-03 L.T. 2.E-02 10/05 10/13 1.16E+04 CU. FT.
1.72E-02 +/- 3.69E-03 L.T. 9.E-03 10/13 10/19 8.53E+03 CU. FT.
1.27E-02 +/- 3.69E-03 L.T. 2.E-02 10/19 10/26 1.01E+04 CU. FT.
2.33E-02 +/- 4.15E-03 L.T. 2.E-02 10/26 11/02 1.OOE+04 CU. FT.
1.72E-02 +/- 3.77E-03 L.T. 2.E-02 11/02 11/09 1.01E+04 CU. FT.
2.67E-02 +/- 4.56E-03 L.T. 1.E-02 11/09 11/16 9.91E+03 CU. FT.
2.40E-02 +/- 4.32E-03 L.T. 2.E-02 11/16 11/23 1.OOE+04 CU. FT.
2.34E-02 +/- 4.23E-03 L.T. 1.E-02 11/23 11/30 1.02E+04 CU. FT.
1.74E-02 +/- 3.78E-03 L.T. 2.E-02 11/30 12/07 9.97E+03 CU. FT.
3.50E-02 +/- 5.07E-03 L.T. 1.E-02 12/07 12/13 8.65E+03 CU. FT.
2.23E-02 +/- 5.87E-03 L.T. 8.E-03 12/13 12/21 1.13E+04 CU. FT.
2.07E-02 +/- 3.76E-03 L.T. 8.E-03 12/21 12/28 1.01E+04 CU. FT.
3.70E-02 +/- 5.32E-03 L.T. 2.E-02
Vl1-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)
STATION NUMBER 01 DATE COLLECTED 12/30 - 03/30 03/30 - 06/29 06/29 - 09/27 09/27 - 12/28 GAMMA SPECTRUM ANALYSIS:
tn gh BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.02E-01 +/- 3.05E-02 L.T. 3.E-02 L.T. I.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. I.E-03 L.T. 4.E-03 L.T. 5.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E+00 L.T. 1.E-03 L.T. 1.E-03 L.T. 3.E-01 L.T. 6.E-03 L.T. 6.E-03 L.T. 2.E-02 L.T. 2.E-02 1.41 E-01 +/- 2.38E-02 L.T. 1.E-02 L.T. 9.E-04 L.T. 1.E-03 L.T. 5.E-03 L.T. 8.E-04 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 7.E-03 L.T. 4.E-01 L.T. 8.E-04 L.T. 9.E-04 L.T. 1.E-01 L.T. 6.E-03 L.T. 6.E-03 L.T. 2.E-02 L.T. 2.E-02 1.23E-01 +/- 1.99E-02 L.T. 2.E-02 L.T. 8.E-04 L.T. 2.E-03 L.T. 5.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 7.E-03 L.T. 2.E-01 L.T. 1.E-03 L.T. 9.E-04 L.T. 9.E-02 L.T. 3.E-03 L.T. 4.E-03 L.T. 2.E-02 L.T. 2.E-02 1.07E-01 +/- 1.88E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 4.E-01 L.T. 9.E-04 L.T. 1.E-03 L.T. I.E-01 L.T. 3.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E-02
Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)
STATION NUMBER 02 DATE COLLECTED 12/30 - 03/30 03/30 - 06/29 06/29 - 09/27 09/27 - 12/28 GAMMA SPECTRUM ANALYSIS:
uj Vl BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.21 E-01 +/- 2.72E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. 2.E-03 L.T. 7.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 4.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 9.E-01 L.T. 1.E-03 L.T. 1.E-03 L.T. 2.E-01 L.T. 6.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02 1.33E-01 +/- 2.95E-02 L.T. 2.E-02 L.T. 9.E-04 L.T. 2.E-03 L.T. 6.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 4.E-01 L.T. 9.E-04 L.T. 9.E-04 L.T. 2.E-01 L.T. 6.E-03 L.T. 6.E-03 L.T. 2.E-02 L.T. 2.E-02 1.32E-01 +/- 2.35E-02 L.T. 2.E-02 L.T. I.E-03 L.T. I.E-03 L.T. 4.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 9.E-03 L.T. 3.E-01 L.T. 9.E-04 L.T. 8.E-04 L.T. 1.E-01 L.T. 4.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E-02 1.26E-01 +/- 2.80E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 5.E-01 L.T. 9.E-04 L.T. 1.E-03 L.T. 2.E-01 L.T. 5.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02
Vl1-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCIICU. M.)
STATION NUMBER 03 DATE COLLECTED 12/30 - 03/30 03/30 - 06/29 06/29 - 09/27 09/27 - 12/28 GAMMA SPECTRUM ANALYSIS:
(n a%
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 9.17E-02 +/- 2.65E-02 L.T. 2.E-02 L.T. 2.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. 2.E-03 L.T. 4.E-03 L.T. 6.E-03 L.T. 4.E-03 L.T. I.E-02 L.T. I.E+00 L.T. 1.E-03 L.T. 2.E-03 L.T. 3.E-01 L.T. 6.E-03 L.T. 7.E-03 L.T. 2.E-02 L.T. 2.E-02 1.37E-01 +/- 2.82E-02 L.T. 5.E-03 L.T. 9.E-04 L.T. 1.E-03 L.T. 5.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 8.E-03 L.T. 4.E-01 L.T. 8.E-04 L.T. 9.E-04 L.T. 1.E-01 L.T. 3.E-03 L.T. 4.E-03 L.T. I.E-02 L.T. I.E-02 1.38E-01 +/- 2.08E-02 L.T. I.E-02 L.T. 6.E-04 L.T. I.E-03 L.T. 2.E-03 L.T. I.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 2.E-01 L.T. 4.E-04 L.T. 7.E-04 L.T. 7.E-02 L.T. 2.E-03 L.T. 3.E-03 L.T. 9.E-03 L.T. 9.E-03 1.12E-01 +/- 3.09E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 1.E-03 L.T. 4.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 5.E-01 L.T. 1.E-03 L.T. 1.E-03 L.T. 2.E-01 L.T. 5.E-03 L.T. 6.E-03 L.T. 2.E-02 L.T. 2.E-02
Vl1-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)
STATION NUMBER 04 DATE COLLECTED 12/30 - 03/30 03/30 - 06/29 06/29 - 09/27 09/27 - 12/28 GAMMA SPECTRUM ANALYSIS:
-1 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.08E-01 +/- 3.62E-02 L.T. 3.E-02 L.T. 2.E-03 L.T. 3.E-03 L.T. 7.E-03 L.T. 2.E-03 L.T. 4.E-03 L.T. 5.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E+00 L.T. 2.E-03 L.T. 2.E-03 L.T. 4.E-01 L.T. 7.E-03 L.T. 7.E-03 L.T. 3.E-02 L.T. 2.E-02 1.45E-01 +/- 3.43E-02 L.T. 2.E-02 L.T. 8.E-04 L.T. I.E-03 L.T. 5.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 7.E-03 L.T. 4.E-01 L.T. 7.E-04 L.T. 7.E-04 L.T. 1.E-01 L.T. 3.E-03 L.T. 4.E-03 L.T. 2.E-02 L.T. 1.E-02 1.37E-01 +/- 1.91E-02 L.T. 7.E-03 L.T. 7.E-04 L.T. 1.E-03 L.T. 9.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 7.E-03 L.T. 2.E-01 L.T. 6.E-04 L.T. 6.E-04 L.T. 7.E-02 L.T. 2.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 8.E-03 1.22E-01 +/- 1.92E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 9.E-04 L.T. 3.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. 4.E-01 L.T. 8.E-04 L.T. 8.E-04 L.T. 2.E-01 L.T. 4.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E-02
Vl1-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)
STATION NUMBER 05 DATE COLLECTED 12/30 - 03/30 03/30 - 06/29 06/29 - 09/27 09/27 - 12/28 GAMMA SPECTRUM ANALYSIS:
tn M:
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.04E-01 +/- 2.45E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. 3.E-03 L.T. 7.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 4.E-03 L.T. 4.E-03 L.T. 9.E-03 L.T. 9.E-01 L.T. 6.E-04 L.T. 1.E-03 L.T. 2.E-01 L.T. 7.E-03 L.T. 7.E-03 L.T. 2.E-02 L.T. 2.E-02 1.48E-01 +/- 2.84E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 9.E-03 L.T. 4.E-01 L.T. 1.E-03 L.T. 1.E-03 L.T. 1.E-01 L.T. 4.E-03 L.T. 5.E-03 L.T. 1.E-02 L.T. 2.E-02 1.30E-01 +/- 2.10E-02 L.T. 2.E-02 L.T. 9.E-04 L.T. 2.E-03 L.T. 5.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 1.E-02 L.T. 3.E-01 L.T. 8.E-04 L.T. 9.E-04 L.T. 1.E-01 L.T. 4.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 2.E-02 1.26E-01 +/- 1.86E-02 L.T. 5.E-03 L.T. 6.E-04 L.T. 1.E-03 L.T. 3.E-03 L.T. 1.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 1.E-03 L.T. 4.E-03 L.T. 2.E-01 L.T. 4.E-04 L.T. 6.E-04 L.T. 1.E-01 L.T. 2.E-03 L.T. 3.E-03 L.T. 9.E-03 L.T. 8.E-03
Vl1-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)
STATION NUMBER 06 DATE COLLECTED 12/30 - 03/30 03/30 - 06/29 06/29 - 09/27 09/27 - 12/28 GAMMA SPECTRUM ANALYSIS:
W
%o BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 8.42E-02 +/- 2.61E-02 L.T. 3.E-02 L.T. 2.E-03 L.T. 2.E-03 L.T. 7.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 4.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 9.E-01 L.T. 1.E-03 L.T. 1.E-03 L.T. 3.E-01 L.T. 5.E-03 L.T. 6.E-03 L.T. 2.E-02 L.T. 2.E-02 1.33E-01 +/- 2.97E-02 L.T. 1.E-02 L.T. I.E-03 L.T. 2.E-03 L.T. 7.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 9.E-03 L.T. 4.E-01 L.T. 1.E-03 L.T. 1.E-03 L.T. 2.E-01 L.T. 5.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02 1.53E-01 +/- 2.28E-02 L.T. 8.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 1.E-02 L.T. 3.E-01 L.T. 1.E-03 L.T. 1.E-03 L.T. 1.E-01 L.T. 4.E-03 L.T. 4.E-03 L.T. 2.E-02 L.T. 2.E-02 1.09E-01 +/- 2.21 E-02 L.T. 1.E-02 L.T. 1.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 9.E-03 L.T. 4.E-01 L.T. 8.E-04 L.T. 8.E-04 L.T. 2.E-01 L.T. 4.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02
Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)
STATION NUMBER 07 DATE COLLECTED 12/30 - 03/30 03/30 - 06/29 06/29 - 09/27 09/27 - 12/28 GAMMA SPECTRUM ANALYSIS:
0 BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 7.56E-02 +/- 3.25E-02 L.T. 3.E-02 L.T. 1.E-03 L.T. 1.E-03 L.T. 5.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 3.E-01 L.T. 9.E-04 L.T. 1.E-03 L.T. 1.E-01 L.T. 4.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02 1.07E-01 +/- 2.80E-02 L.T. 2.E-02 L.T. I.E-03 L.T. 2.E-03 L.T. 4.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 9.E-03 L.T. 5.E-01 L.T. 8.E-04 L.T. 8.E-04 L.T. 2.E-01 L.T. 6.E-03 L.T. 6.E-03 L.T. 2.E-02 L.T. 2.E-02 9.89E-02 +/- 2.29E-02 L.T. 6.E-03 L.T. 9.E-04 L.T. 1.E-03 L.T. 4.E-03 L.T. 8.E-04 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. 2.E-01 L.T. 8.E-04 L.T. 8.E-04 L.T. 1.E-01 L.T. 3.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E-02 9.27E-02 +/- 1.85E-02 L.T. 2.E-03 L.T. 8.E-04 L.T. 1.E-03 L.T. 3.E-03 L.T. 6.E-04 L.T. 2.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 3.E-01 L.T. 6.E-04 L.T. 6.E-04 L.T. 1.E-01 L.T. 3.E-03 L.T. 3.E-03 L.T. 7.E-03 L.T. 9.E-03
Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)
STATION NUMBER 08 DATE COLLECTED 12/30 - 03/30 03/30 - 06/29 06/29 - 09/27 09/27 - 12/28 GAMMA SPECTRUM ANALYSIS:
M' p-BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 9.91E-02 + 1.82E-02 L.T. 1.E-02 L.T. 8.E-04 L.T. 1.E-03 L.T. 4.E-03 L.T. 8.E-04 L.T. 2.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 5.E-01 L.T. 6.E-04 L.T. 7.E-04 L.T. 2.E-01 L.T. 3.E-03 L.T. 3.E-03 L.T. I.E-02 L.T. 1.E-02 1.40E-01 +/- 2.61E-02 L.T. 2.E-02 L.T. 8.E-04 L.T. I.E-03 L.T. 3.E-03 L.T. 5.E-04 L.T. 1.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. 4.E-01 L.T. 6.E-04 L.T. 5.E-04 L.T. 1.E-01 L.T. 4.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. I.E-02 1.17E-01 +/- 2.55E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 4.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 4.E-01 L.T. I.E-03 L.T. I.E-03 L.T. 1.E-01 L.T. 5.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02 1.17E-01 +/- 2.14E-02 L.T. 6.E-03 L.T. 1.E-03 L.T. 1.E-03 L.T. 5.E-03 L.T. 9.E-04 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. 4.E-01 L.T. 9.E-04 L.T. 1.E-03 L.T. 1.E-01 L.T. 4.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E-02
VII-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)
STATION NUMBER 09 DATE COLLECTED 12/30 - 03/30 03/30 - 06/29 06/29 - 09/27 09/27 - 12/28 GAMMA SPECTRUM ANALYSIS:
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 1.16E-01 +/- 3.14E-02 L.T. 3.E-02 L.T. 1.E-03 L.T. 3.E-03 L.T. 8.E-03 L.T. 1.E-03 L.T. 3.E-03 L.T. 5.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E400 L.T. 1.E-03 L.T. 1.E-03 L.T. 3.E-01 L.T. 6.E-03 L.T. 6.E-03 L.T. 2.E-02 L.T. 2.E-02 1.42E-01 +/- 2.62E-02 L.T. 2.E-02 L.T. 7.E-04 L.T. I.E-03 L.T. 5.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. 3.E-01 L.T. 8.E-04 L.T. 8.E-04 L.T. 1.E-01 L.T. 3.E-03 L.T. 3.E-03 L.T. 1.E-02 L.T. 1.E-02 1.43E-01 +/- 1.99E-02 L.T. 2.E-03 L.T. 7.E-04 L.T. 1.E-03 L.T. 4.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 7.E-03 L.T. 2.E-01 L.T. 6.E-04 L.T. 7.E-04 L.T. 1.E-01 L.T. 4.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02 1.15E-01 +/- 2.07E-02 L.T. 2.E-02 L.T. 1.E-03 L.T. I.E-03 L.T. 5.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 8.E-03 L.T. 4.E-01 L.T. 7.E-04 L.T. 8.E-04 L.T. 1.E-01 L.T. 3.E-03 L.T. 4.E-03 L.T. 2.E-02 L.T. 1.E-02
Vll-2 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE COMPOSITE AIR PARTICULATE FILTERS (PCI/CU. M.)
STATION NUMBER 10 DATE COLLECTED 12/30 - 03/30 03130 - 06/29 06/29 - 09/27 09/27 - 12/28 GAMMA SPECTRUM ANALYSIS:
w BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 8.77E-02 + 3.02E-02 L.T. 3.E-02 L.T. 2.E-03 L.T. 3.E-03 L.T. 9.E-03 L.T. 2.E-03 L.T. 4.E-03 L.T. 5.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 8.E-01 L.T. I.E-03 L.T. I.E-03 L.T. 3.E-01 L.T. 6.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 2.E-02 1.25E-01 + 2.43E-02 L.T. 9.E-03 L.T. 1.E-03 L.T. 2.E-03 L.T. 5.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 3.E-03 L.T. 9.E-03 L.T. 4.E-01 L.T. 8.E-04 L.T. 1.E-03 L.T. 1.E-01 L.T. 4.E-03 L.T. 4.E-03 L.T. 2.E-02 L.T. 1.E-02 1.12E-01 + 1.92E-02 L.T. I.E-02 L.T. 8.E-04 L.T. 1.E-03 L.T. 4.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 3.E-03 L.T. 2.E-03 L.T. 6.E-03 L.T. 2.E-01 L.T. 8.E-04 L.T. 8.E-04 L.T. 1.E-01 L.T. 4.E-03 L.T. 5.E-03 L.T. 2.E-02 L.T. 1.E-02 7.01 E-02 +/- 2.51 E-02 L.T. 2.E-02 L.T. I.E-03 L.T. I.E-03 L.T. 4.E-03 L.T. I.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 2.E-03 L.T. 8.E-03 L.T. 3.E-01 L.T. 8.E-04 L.T. 8.E-04 L.T. I.E-01 L.T. 3.E-03 L.T. 4.E-03 L.T. 1.E-02 L.T. 1.E-02
Vll-3 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION FISH (PCIIKG WET)
STATION NUMBER 28 DATE COLLECTED:
07/21/2004 CARP 07/21/2004 CATFISH 09/28/2004 CARP 09/28/2004 CATFISH GAMMA SPECTRUM ANALYSIS:
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 8.E+01 3.31E+03 +/- 2.18E+02 L.T. 1.E+01 L.T. 1.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 9.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 5.E+01 L.T. 1.E+01 L.T. 5.E+01 L.T. 2.E+02 L.T. 2.E+02 L.T. I.E+02 2.80E+03 +/- 2.50E+02 L.T. 1.E+01 L.T. 1.E+01 L.T. 3.E+01 L.T. 1.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 1.E+02 L.T. 2.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 6.E+01 L.T. 2.E+01 L.T. 7.E+01 L.T. 2.E+02 L.T. 2.E+02 L.T. 1.E+02 3.43E+03 +/- 2.39E+02 L.T. 1.E+01 L.T. 1.E+01 L.T. 3.E+01 L.T. 1.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 1.E+02 L.T. 4.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 9.E+01 L.T. 3.E+01 L.T. 9.E+01 L.T. 3.E+02 L.T. 3.E+02 L.T. 9.E+01 3.49E+03 +/- 2.38E+02 L.T. 1.E+01 L.T. I.E+01 L.T. 3.E+01 L.T. I.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. I.E+01 L.T. 9.E+01 L.T. 3.E+01 L.T. 1.E+01 L.T. I.E+01 L.T. 8.E+01 L.T. 2.E+01 L.T. 6.E+01 L.T. 3.E+02 L.T. 2.E+02
Vll-3 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION FISH (PCI/KG WET)
STATION NUMBER 35 DATE COLLECTED:
07/21/2004 CARP 07/21/2004 CATFISH 09/29/2004 CARP 09/29/2004 CATFISH GAMMA SPECTRUM ANALYSIS:
a'W BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 9.E+01 3.52E+03 +/- 2.99E+02 L.T. 1.E+01 L.T. 1.E+01 L.T. 2.E+01 L.T. 9.E+00 L.T. 2.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. I.E+02 L.T. 2.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 5.E+01 L.T. 1.E+01 L.T. 6.E+01 L.T. 2.E+02 L.T. 2.E+02 L.T. I.E+02 3.23E+03 +/- 3.20E+02 L.T. 1.E+01 L.T. I.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. I.E+01 L.T. I.E+02 L.T. 2.E+01 L.T. I.E+01 L.T. I.E+01 L.T. 6.E+01 L.T. 2.E+01 L.T. 7.E+01 L.T. 3.E+02 L.T. 2.E+02 L.T. 1.E+02 3.08E+03 +/- 2.81E+02 L.T. 2.E+01 L.T. 2.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 3.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 1.E+02 L.T. 5.E+01 L.T. 1.E+01 L.T. 2.E+01 L.T. 1.E+02 L.T. 2.E+01 L.T. 7.E+01 L.T. 3.E+02 L.T. 3.E+02 L.T. I.E+02 2.98E+03 +/- 2.99E+02 L.T. I.E+01 L.T. 1.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. I.E+02 L.T. 3.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 7.E+01 L.T. 2.E+01 L.T. 6.E+01 L.T. 2.E+02 L.T. 2.E+02
VII-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)
STATION NUMBER 99 DATE COLLECTED:
01/06/2004 02/03/2004 03/02/2004 04/06/2004 RADIOCHEMICAL ANALYSIS:
1-131 L.T. 6.E-01 L.T. 6.E-01 L.T. 7.E-01 L.T. 4.E-01 GAMMA SPECTRUM ANALYSIS:
0m ai BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 3.E+01 1.21E+03 +/- 9.03E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. l.E+01 L.T. 5.E+00 L.T. 1.E+01 L.T. 8.E+00 L.T. 4.E+00 L.T. 4.E+01 L.T. 6.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 9.E+01 L.T. 7.E+01 L.T. 4.E+01 1.24E+03 +/- 9.87E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. l.E+01 L.T. 5.E+00 L.T. 1.E+01 L.T. 8.E+00 L.T. 4.E+00 L.T. 4.E+01 L.T. 7.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 9.E+01 L.T. 7.E+00 L.T. 8.E+01 1.34E+03 +/- 2.26E+02 L.T. 1.E+01 L.T. I.E+01 L.T. 3.E+01 L.T. I.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. I.E+02 L.T. 2.E+01 L.T. 1.E+01 L.T. l.E+01 L.T. 5.E+01 L.T. 2.E+01 L.T. 7.E+01 L.T. 2.E+02 L.T. 2.E+01 L.T. 2.E+01 1.32E+03 +/- 8.07E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 2.E+01 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. l.E+01 L.T. 5.E+01 L.T. 5.E+01
Vl1-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)
STATION NUMBER 99 DATE COLLECTED:
05/04/2004 05/25/2004 06/08/2004 06/22/2004 RADIOCHEMICAL ANALYSIS:
1-131 L.T. 8.E-01 L.T. 7.E-01 L.T. 5.E-01 L.T. 3.E-01 GAMMA SPECTRUM ANALYSIS:
O'h BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 6.E+01 1.39E+03 +/- 2.12E+02 L.T. 7.E+00 L.T. 7.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 1.E+01 L.T. 8.E+00 L.T. 6.E+01 L.T. 1.E+01 L.T. 6.E+00 L.T. 8.E+00 L.T. 3.E+01 L.T. 1.E+01 L.T. 5.E+01 L.T. 2.E+02 L.T. I.E+02 L.T. 3.E+01 1.36E+03 +/- 7.36E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 4.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. I.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 8.E+01 L.T. 6.E+01 L.T. 2.E+01 1.12E+03 +/- 6.79E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 7.E+01 L.T. 6.E+01 L.T. 2.E+01 1.24E+03 +/- 6.66E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 2.E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 7.E+01 L.T. 5.E+01
Vl1-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)
STATION NUMBER 99 DATE COLLECTED:
07/06/2004 07/1912004 08/10/2004 08/17/2004 RADIOCHEMICAL ANALYSIS:
1-131 L.T. 6.E-01 L.T. 7.E-01 L.T. 2.E-01 L.T. 7.E-01 GAMMA SPECTRUM ANALYSIS:
an BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 2.E+01 1.12E+03 +/- 6.57E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 4.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 8.E+01 L.T. 6.E+01 L.T. 2.E+01 1.30E+03 +/- 7.14E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 4.E+00 L.T. 7.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 4.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 6.E+01 L.T. 6.E+01 L.T. 6.E+01 1.36E+03 +/- 2.11 E+02 L.T. 8.E+00 L.T. 7.E+00 L.T. 1.E+01 L.T. 9.E+00 L.T. 2.E+01 L.T. 1.E+01 L.T. 8.E+00 L.T. 7.E+01 L.T. 1.E+01 L.T. 7.E+00 L.T. 9.E+00 L.T. 4.E+01 L.T. 1.E+01 L.T. 5.E+01 L.T. 2.E+02 L.T. 2.E+02 L.T. 9.E+01 1.22E+03 +/- 2.46E+02 L.T. 1.E+01 L.T. 9.E+00 L.T. 1.E+01 L.T. 1.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. 7.E+00 L.T. 8.E+01 L.T. 1.E+01 L.T. 8.E+00 L.T. 9.E+00 L.T. 4.E+01 L.T. 1.E+01 L.T. 6.E+01 L.T. 2.E+02 L.T. 2.E+02
Vl1-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)
STATION NUMBER 99 DATE COLLECTED:
09/07/2004 09/21/2004 10/05/2004 11/02/2004 RADIOCHEMICAL ANALYSIS:
1-131 L.T. 3.E-01 L.T. 4.E-01 L.T. 5.E-01 L.T. 5.E-01 GAMMA SPECTRUM ANALYSIS:
0o
%D BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 3.E+01 1.38E+03 +/- 9.52E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. 9.E+00 L.T. 4.E+00 L.T. 1.E+01 L.T. 7.E+00 L.T. 4.E+00 L.T. 4.E+01 L.T. 6.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 7.E+00 L.T. 3.E+01 L.T. 9.E+01 L.T. 8.E+01 L.T. 4.E+01 1.31E+03 +/- 1.20E+02 L.T. 4.E+00 L.T. 4.E+00 L.T. 1.E+01 L.T. 5.E+00 L.T. 1.E+01 L.T. 9.E+00 L.T. 5.E+00 L.T. 4.E+01 L.T. 7.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 2.E+01 L.T. 9.E+00 L.T. 3.E+01 L.T. 1.E+02 L.T. 1.E+02 L.T. 3.E+01 1.31E+03 +/- 7.83E+01 L.T. 4.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 4.E+00 L.T. 8.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 4.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 1.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 8.E+01 L.T. 6.E+01 L.T. 2.E+01 1.27E+03 +/- 1.23E+02 L.T. 3.E+00 L.T. 3.E+00 L.T. 8.E+00 L.T. 5.E+00 L.T. 9.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+01 L.T. 3.E+00 L.T. 2.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 6.E+01 L.T. 5.E+01
Vl1-4 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK NEAREST PRODUCER (PCI/LITER)
STATION NUMBER 99 DATE COLLECTED:
12/07/2004 RADIOCHEMICAL ANALYSIS:
1-131 L.T. 2.E-01 GAMMA SPECTRUM ANALYSIS:
BE-7 L.T. 4.E+01 K-40 1.26E+03 +/- 1.43E+02 MN-54 L.T. 4.E+00 CO-58 L.T. 4.E+00 FE-59 L.T. 9.E+00 CO-60 L.T. 4.E+00 ZN-65 L.T. 1.E+01 ZR-95 L.T. 8.E+00 RU-103 L.T. 4.E+00 RU-106 L.T. 4.E+01 1-131 L.T. 7.E+00 CS-1 34 L.T. 4.E+00 CS-137 L.T. 4.E+00 BA-140 L.T. 2.E+01 CE-141 L.T. 7.E+00 CE-144 L.T. 3.E+01 RA-226 L.T. 1.E+02 TH-228 L.T. 8.E+01
Vl1-5 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK OTHER PRODUCERS (PCI/LITER)
STATION NUMBER 100 DATE COLLECTED:
01/06/04 03131/04 07/06/04 RADIOCHEMICAL ANALYSIS:
1-131 L.T. 6.E-01 L.T. 3.E-0I (a)
GAMMA SPECTRUM ANALYSIS:
-a F-a BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-1 37 BA-1 40 CE-141 CE-144 RA-226 TH-228 L.T. 3.E+01 1.36E+03 +/- 7.82E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. 8.E+00 L.T. 4.E+00 L.T. 9.E+00 L.T. 6.E+00 L.T. 4.E+00 L.T. 3.E+01 L.T. 5.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 6.E+01 L.T. 6.E+01 L.T. 6.E+01 1.25E+03 +/- 1.69E+02 L.T. 8.E+00 L.T. 8.E+00 L.T. 2.E+01 L.T. 9.E+00 L.T. 2.E+01 L.T. 2.E+01 L.T. 8.E+00 L.T. 8.E+01 L.T. 1.E+01 L.T. 8.E+00 L.T. 8.E+00 L.T. 4.E+01 L.T. 1.E+01 L.T. 4.E+01 L.T. 2.E+02 L.T. 2.E+02 (a) Station 100 went out of business In March 2004.
Vll-5 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK OTHER PRODUCERS (PCI/LITER)
STATION NUMBER 102 DATE COLLECTED:
01/06/04 04/06/04 07/06/04 10/05/04 RADIOCHEMICAL ANALYSIS:
1-131 L.T. 5.E-01 L.T. 4.E-01 L.T. 4.E-01 L.T. 5.E-01 GAMMA SPECTRUM ANALYSIS:
N' BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-1 40 CE-141 CE-144 RA-226 TH-228 L.T. 2.E+01 1.24E+03 +/- 8.33E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 2.E+01 L.T. 4.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. I.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 7.E+01 L.T. 5.E+01 L.T. 3.E+01 1.25E+03 +/- 8.68E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. 9.E+00 L.T. 4.E+00 L.T. 9.E+00 L.T. 7.E+00 L.T. 4.E+00 L.T. 4.E+01 L.T. 8.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 9.E+01 L.T. 7.E+01 L.T. 3.E+01 1.35E+03 +/- 1.03E+02 L.T. 4.E+00 L.T. 4.E+00 L.T. 9.E+00 L.T. 5.E+00 L.T. 1.E+01 L.T. 8.E+00 L.T. 4.E+00 L.T. 4.E+01 L.T. 5.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 9.E+01 L.T. 8.E+01 L.T. 3.E+01 1.26E+03 +/- 9.08E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. 9.E+00 L.T. 5.E+00 L.T. 9.E+00 L.T. 7.E+00 L.T. 4.E+00 L.T. 4.E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 9.E+01 L.T. 7.E+01
Vll-5 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION MILK OTHER PRODUCERS (PCI/LITER)
STATION NUMBER 103 (b)
DATE COLLECTED:
07/06/04 10/05/04 RADIOCHEMICAL ANALYSIS:
1-131 L.T. 4.E-01 L.T. 3.E-01 GAMMA SPECTRUM ANALYSIS:
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-1 37 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 3.E+01 1.17E+03 +/- 7.78E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. 8.E+00 L.T. 4.E+00 L.T. 8.E+00 L.T. 7.E+00 L.T. 4.E+00 L.T. 3.E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 1.E+01 L.T. 6.E+00 L.T. 3.E+01 L.T. 9.E+01 L.T. 8.E+01 L.T. 2.E+01 1.18E+03 +/- 7.29E+01 L.T. 2.E+00 L.T. 2.E+00 L.T. 5.E+00 L.T. 2.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+01 L.T. 2.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 8.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+01 L.T. 4.E+01 (b) Station 103 replaced station 100.
Vl1-6 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)
STATION NUMBER 11 DATE COLLECTED:
01/12/04 04112/04 07/13/04 10/06/04 RADIOCHEMICAL ANALYSIS:
1-131 L.T. 8. E-01 L.T. 6. E-01 L.T. 7. E-01 L.T. 3. E-01 GAMMA SPECTRUM ANALYSIS:
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 3. E+01 L.T. 8. E+01 L.T. 4. E+00 L.T. 4. E+00 L.T. 7. E+00 L.T. 4. E+00 L.T. 8. E+00 L.T. 6. E+00 L.T. 3. E+00 L.T. 3. E+01 L.T. 4. E+00 L.T. 3. E+00 L.T. 4. E+00 L.T. 1. E+01 L.T. 5. E+00 L.T. 2. E+01 L.T. 7. E+01 L.T. 8. E+01 L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
- 3. E+01
- 8. E+01
- 3. E+00
- 3. E+00
- 7. E+00
- 3. E+00
- 6. E+00
- 6. E+00
- 3. E+00
- 3. E+01
- 4. E+00
- 3. E+00
- 3. E+00
- 1. E+01
- 5. E+00
- 2. E+01
- 7. E+01
- 6. E+01 L.T. 3. E+01 L.T. 8. E+01 L.T. 3. E+00 L.T. 3. E+00 L.T. 6. E+00 L.T. 3. E+00 L.T. 6. E+00 L.T. 5. E+00 L.T. 3. E+00 L.T. 3. E+01 L.T. 5. E+00 L.T. 3. E+00 L.T. 3. E+00 L.T. 1. E+01 L.T. 5. E+00 L.T. 2. E+01 L.T. 6. E+01 L.T. 6. E+01 L.T. 4. E+01 L.T. 8. E+01 L.T. 4. E+00 L.T. 4. E+00 L.T. 9. E+00 L.T. 5. E+00 L.T. 1. E+01 L.T. 7. E+00 L.T. 5. E+00 L.T. 3. E+01 L.T. 9. E+00 L.T. 4. E+00 L.T. 5. E+00 L.T. 2. E+01 L.T. 9. E+00 L.T. 4. E+01 L.T. 1. E+02 L.T. 1. E+02 TRITIUM ANALYSIS:
H-3 L.T. 2. E+02 L.T. 2. E+02 L.T. 2. E+02 L.T. 2. E+02
Vl1-6 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - GROUND (PCI/LITER)
STATION NUMBER 47 DATE COLLECTED:
01/12/04 04/12/04 07/13/04 10/06/04 RADIOCHEMICAL ANALYSIS:
1-131 L.T. 8. E-01 L.T. 5. E-01 L.T. 6. E-01 L.T. 5. E-01 GAMMA SPECTRUM ANALYSIS:
-J t'
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 3. E+01 L.T. 9. E+01 L.T. 4. E+00 L.T. 4. E+00 L.T. 8. E+00 L.T. 4. E+00 L.T. 1. E+01 L.T. 7. E+00 L.T. 4. E+00 L.T. 4. E+01 L.T. 5. E+00 L.T. 4. E+00 L.T. 4. E+00 L.T. 2. E+01 L.T. 6. E+00 L.T. 2. E+01 L.T. 8. E+01 1.15E+02 +/- 6.24E+01 L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
- 2. E+01
- 5. E+01
- 2. E+00
- 2. E+00
- 4. E+00
- 2. E+00
- 5. E+00
- 4. E+00
- 2. E+00
- 2. E+01
- 3. E+00
- 2. E+00
- 2. E+00
- 1. E+01
- 4. E+00
- 1. E+01
- 6. E+01
- 4. E+01 L.T. 3. E+01 L.T. 3. E+01 L.T. 3. E+00 L.T. 3. E+00 L.T. 7. E+00 L.T. 4. E+00 L.T. 7. E+00 L.T. 6. E+00 L.T. 3. E+00 L.T. 3. E+01 L.T. 5. E+00 L.T. 3. E+00 L.T. 4. E+00 L.T. 2. E+01 L.T. 5. E+00 L.T. 2. E+01 L.T. 8. E+01 L.T. 7. E+01 L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
- 6. E+01
- 6. E+01
- 7. E+00
- 6. E+00
- 1. E+01
- 6. E+00
- 1. E+01
- 1. E+01
- 7. E+00
- 7. E+01
- 8. E+00
- 6. E+00
- 7. E+00
- 2. E+01
- 1. E+01
- 5. E+01
- 1. E+02
- 1. E+02 TRITIUM ANALYSIS:
H-3 L.T. 2. E+02 L.T. 2. E+02 L.T. 2. E+02 L.T. 2. E+02
Vl1-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)
STATION NUMBER 28 DATE COLLECTED:
01/12/04 02/04/04 03/02/04 04/12/04 05/04/04 GAMMA SPECTRUM ANALYSIS:
-Ja'i BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
3.E+01 9.E+01 4.E+00 4.E+00 8.E+00 4.E+00 8.E+00 6.E+00 4.E+00 3.E+01 5.E+00 4.E+00 4.E+00 2.E+01 5.E+00 2.E+01 9.E+01 7.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. 2.E+00 L.T. 3.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 4.E+00 L.T. 3.E+00 L.T. 2.E+01 L.T. 4.E+00 L.T. 2.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 7.E+01 L.T. 5.E+01 L.T. 2.E+01 L.T. 6.E+01 L.T. 2.E+00 L.T. 2.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+01 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 1.E+01 L.T. 3.E+00 L.T. 1.E+01 L.T. 5.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 3.E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 4.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 4.E+00 L.T. 2.E+01 L.T. 7.E+01 L.T. 6.E+01 L.T. 4.E+01 L.T. 9.E+01 L.T. 4.E+00 L.T. 4.E+00 L.T. 9.E+00 L.T. 4.E+00 L.T. 1.E+01 L.T. 8.E+00 L.T. 4.E+00 L.T. 4.E+01 L.T. 7.E+00 L.T. 4.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 9.E+01 L.T. 8.E+01 TRITIUM ANALYSIS:
H-3 01/12 - 03/02 L.T. 3.E+02
Vl1-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)
STATION NUMBER 28 DATE COLLECTED:
06/01/04 07/06/04 08/03/04 09/07/04 10/04/04 GAMMA SPECTRUM ANALYSIS:
BE-7 L.T. 2.E+01 L.T. 2.E+01 L.T. 3.E+01 L.T. 3.E+01 L.T. 4.E+01 K-40 L.T. 3.E+01 L.T. 3.E+01 L.T. 8.E+01 L.T. 9.E+01 L.T. 1.E+02 MN-54 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 5.E+00 CO-58 L.T. 2.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 5.E+00 FE-59 L.T. 5.E+00 L.T. 6.E+00 L.T. 6.E+00 L.T. 8.E+00 L.T. 9.E+00 CO-60 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 5.E+00 ZN-65 L.T. 5.E+00 L.T. 6.E+00 L.T. 6.E+00 L.T. 7.E+00 L.T. 1.E+01 ZR-95 L.T. 4.E+00 L.T. 5.E+00 L.T. 6.E+00 L.T. 6.E+00 L.T. 8.E+00 RU-103 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 5.E+00 RU-106 L.T. 2.E+01 L.T. 3.E+01 L.T. 3.E+01 L.T. 3.E+01 L.T. 4.E+01 1-131 L.T. 3.E+00 L.T. 3.E+00 L.T. 8.E+00 L.T. 6.E+00 L.T. 6.E+00 CS-134 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 5.E+00 CS-137 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 5.E+00 BA-140 L.T. 1.E+01 L.T. 1.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. 2.E+01 CE-141 L.T. 4.E+00 L.T. 4.E+00 L.T. 5.E+00 L.T. 6.E+00 L.T. 7.E+00 CE-144 L.T. 2.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. 3.E+01 RA-226 L.T. 7.E+01 L.T. 6.E+01 L.T. 6.E+01 L.T. 9.E+01 L.T. 1.E+02 TH-228 L.T. 5.E+01 L.T. 5.E+01 L.T. 5.E+01 L.T. 7.E+01 L.T. 1.E+02 TRITIUM ANALYSIS:
04/12 - 06/01 07/06 - 09/07 H-3 L.T. 2.E+02 L.T. 2.E+02
VII-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)
STATION NUMBER 28 DATE COLLECTED:
11/02/04 12/07/04 GAMMA SPECTRUM ANALYSIS:
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 4.E+01 L.T. 1.E+02 L.T. 6.E+00 L.T. 5.E+00 L.T. 1.E+01 L.T. 6.E+00 L.T. 8.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 5.E+01 L.T. 5.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+01 L.T. 1.E+01 L.T. 4.E+01 L.T. I.E+02 L.T. 1.E+02 L.T. 3.E+01 L.T. 3.E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 6.E+00 L.T. 4.E+00 L.T. 3.E+01 L.T. 5.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 6.E+00 L.T. 2.E+01 L.T. 8.E+01 L.T. 7.E+01 TRITIUM ANALYSIS:
H-3 10/04 - 12/07 L.T. 2.E+02
VII-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)
STATION NUMBER 35 DATE COLLECTED:
01/12/04 02/11/04 03/02/04 04/12/04 05/04/04 GAMMA SPECTRUM ANALYSIS:
BE-7 L.T. 2.E+01 L.T. 2.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 7.E+01 K-40 L.T. 8.E+01 L.T. 7.E+01 L.T. 7.E+01 L.T. 5.E+01 L.T. 2.E+02 MN-54 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 9.E+00 CO-58 L.T. 2.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 9.E+00 FE-59 L.T. 5.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 2.E+01 CO-60 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 9.E+00 ZN-65 L.T. 5.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 2.E+01 ZR-95 L.T. 5.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 2.E+01 RU-103 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 8.E+00 RU-106 L.T. 2.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 8.E+01 1-131 L.T. 4.E+00 L.T. 5.E+00 L.T. 5.E+00 L.T. 2.E+00 L.T. 1.E+01 CS-1 34 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 2.E+00 L.T. 9.E+00 CS-137 L.T. 3.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 2.E+00 L.T. 9.E+00 BA-140 L.T. I.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 7.E+00 L.T. 5.E+01 CE-141 L.T. 4.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. I.E+01 CE-144 L.T. 2.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 9.E+00 L.T. 5.E+01 RA-226 L.T. 6.E+01 L.T. 7.E+01 L.T. 5.E+01 L.T. 3.E+01 L.T. 2.E+02 TH-228 L.T. 5.E+01 L.T. 5.E+00 L.T. 5.E+00 L.T. 3.E+01 L.T. 2.E+02 TRITIUM ANALYSIS:
01/12 - 03/02 H-3 L.T. 2.E+02
Vll-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)
STATION NUMBER 35 DATE COLLECTED:
06/01/04 07/06/04 08/03/04 09/07/04 10/04/04 GAMMA SPECTRUM ANALYSIS:
CD 0
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 2.E+01 L.T. 7.E+01 L.T. 3.E+00 L.T. 2.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 5.E+00 L.T. 4.E+00 L.T. 2.E+00 L.T. 2.E+01 L.T. 3.E+00 L.T. 2.E+00 L.T. 3.E+00 L.T. 9.E+00 L.T. 4.E+00 L.T. 2.E+01 L.T. 6.E+01 L.T. 5.E+01 L.T. 3.E+01 L.T. 8.E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 7.E+00 L.T. 4.E+00 L.T. 7.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 4.E+00 L.T. 3.E+00 L.T. 4.E+00 L.T. 1.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 9.E+01 L.T. 7.E+01 L.T. 3.E+01 L.T. 6.E+01 L.T. 5.E+00 L.T. 4.E+00 L.T. 1.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 8.E+00 L.T. 5.E+00 L.T. 4.E+01 L.T. 1.E+01 L.T. 3.E+00 L.T. 4.E+00 L.T. 3.E+01 L.T. 7.E+00 L.T. 2.E+01 L.T. 7.E+01 L.T. 7.E+01 L.T. 2.E+01 L.T. 7.E+01 L.T. 3.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 3.E+00 L.T. 6.E+00 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+01 L.T. 5.E+00 L.T. 3.E+00 L.T. 3.E+00 L.T. 1.E+01 L.T. 5.E+00 L.T. 2.E+01 L.T. 8.E+01 L.T. 7.E+01 L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
L.T.
2.E+01 8.E+01 3.E+00 2.E+00 5.E+00 2.E+00 6.E+00 4.E+00 3.E+00 3.E+01 4.E+00 3.E+00 3.E+00 1.E+01 4.E+00 2.E+01 6.E+01 5.E+01 TRITIUM ANALYSIS:
H-3 04/12 - 06/01 L.T. 2.E+02 07/06 - 09/07 L.T. 2.E+02
Vl1-7 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION WATER - RIVER (PCI/LITER)
STATION NUMBER 35 DATE COLLECTED:
11/02/04 12/07/04 GAMMA SPECTRUM ANALYSIS:
BE-7 L.T. 4.E+01 L.T. 2.E+01 K-40 L.T. 1.E+02 L.T. 2.E+01 MN-54 L.T. 5.E+00 L.T. 3.E+00 CO-58 L.T. 5.E+00 L.T. 2.E+00 FE-59 L.T. 1.E+01 L.T. 5.E+00 CO-60 L.T. 3.E+00 L.T. 3.E+00 CD ZN-65 L.T. 9.E+00 L.T. 6.E+00 ZR-95 L.T. 8.E+00 L.T. 5.E+00 RU-103 L.T. 6.E+00 L.T. 3.E+00 RU-106 L.T. 4.E+01 L.T. 3.E+01 1-131 L.T. 6.E+00 L.T. 4.E+00 CS-134 L.T. 3.E+00 L.T. 2.E+00 CS-137 L.T. 4.E+00 L.T. 3.E+00 BA-140 L.T. 2.E+01 L.T. 1.E+01 CE-141 L.T. 7.E+00 L.T. 5.E+00 CE-144 L.T. 3.E+01 L.T. 2.E+01 RA-226 L.T. 1.E+02 L.T. 8.E+01 TH-228 L.T. 8.E+01 L.T. 6.E+01 TRITIUM ANALYSIS:
10/04-12/07 H-3 L.T. 2.E+02
V11-8 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - THERMOLUMINESCENT DOSIMETRY - TLD millirem/Quarter Sample Station First Quarter Second Quarter Third Quarter Fourth Quarter Quarter Average Nuclide Number 01/05-04/14 04/14-07/07 07/07-10/13 10/13-01(05
+/- 1 std dev.
TLD 01 4.0 +/- 0.7 11.1 +/- 1.1 3.8 +/- 0.5 10.6 +/- 0.2 7.4 +/- 4.0 02 5.5 +/- 0.2 3.8 +/- 1.0 3.3 +/- 1.4 10.3 +/- 1.3 5.7 +/- 3.2 03 7.0 +/- 0.7 10.4 +/- 0.5 0.8 +/- 0.6 12.3 +/- 0.5 7.6 +/- 5.1 04 10.7 +/- 0.1 3.1 +/- 0.8 2.3 +/- 0.9 10.0 +/- 0.3 6.5 +/- 4.4 05 6.2 +/- 1.2 6.7 +/- 0.3 2.3 +/- 0.5 6.1 +/- 2.1 5.3 +/- 2.0 06 6.4 +/- 0.4 4.1 +/- 0.4 1.5 +/- 0.3 12.2 +/- 0.0 6.1 +/- 4.6 07 5.0 +/- 0.5 3.0 +/- 0.8 5.4 +/- 2.1 11.2 +/- 1.0 6.2 +/- 3.5 08 6.8 +/- 1.4 10.2 +/- 0.8 5.5 +/- 0.9 10.3 +/- 0.5 8.2 +/- 2.4 09 7.7 +/- 0.3 8.2 +/- 0.0 3.6 +/- 2.0 6.7 +/- 0.8 6.6 +/- 2.1 10 6.1 +/- 0.2 6.1 +/- 0.6 3.9 +/- 1.4 11.5 +/- 0.0 6.9 +/- 3.2 o
20 9.2 +/- 0.2 8.1 +/- 0.1 2.6 +/- 0.6 12.8 +/- 0.9 8.2 +/- 4.2 44 10.5 +/- 2.1 12.8 +/- 1.2 4.4 +/- 0.8 9.5 +/- 0.3 9.3 +/- 3.5 56 10.2 +/- 0.3 9.2 +/- 1.2 4.3 +/- 1.2 17.3 +/- 0.2 10.3 +/- 5.4 58 9.6 +/- 0.5 8.0 +/- 0.3 2.4 +/- 1.4 12.1 +/- 1.1 8.0 +/- 4.1 59 9.2 +/- 0.2 3.9 +/- 0.1 5.4 +/- 1.7 14.4 +/- 1.2 8.2 +/- 4.7 66 10.3 +/- 1.2 5.8 +/- 0.3 6.2 +/- 0.3 10.2 +/- 0.2 8.1 +/- 2.5 67 7.9 +/- 0.0 8.1 +/- 0.3 5.7 +/- 1.8 19.2 +/- 1.3 10.2 +/- 6.1 71 7.5 +/- 1.1 9.5 +/- 0.8 8.5 +/- 0.6 14.9 +/- 1.9 10.1 +/- 3.3 79 8.6 +/- 1.0 4.8 +/- 1.3 4.1 +/- 0.6 16.4 +/- 0.1 8.5 +/- 5.6 80 10.2 +/- 1.2 8.3 +/- 3.1 7.4 +/- 0.4 11.4 +/- 0.3 9.3 +/- 1.8 81 5.7 +/- 0.2 5.2 +/- 1.4 3.2 +/- 1.9 11.3 +/- 0.6 6.4 +/- 3.5 82 8.3 +/- 0.4 8.4 +/- 0.7 4.9 +/- 1.5 9.7 +/- 2.2 7.8 +/- 2.1 83 6.4 +/- 1.1 6.0 +/- 0.9 9.5 +/- 2.4 10.6 +/- 1.0 8.1 +/- 2.3 84 7.1 +/- 1.3 4.9 +/- 0.3 5.7 +/- 0.1 13.6 +/- 0.2 7.8 +/- 4.0 85 6.9 +/- 1.1 3.8 +/- 0.7 3.1 +/- 1.4 10.7 +/- 1.1 6.1 +/- 3.5
VII-8 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - THERMOLUMINESCENT DOSIMETRY - TLD millirem/Quarter Sample Station First Quarter Second Quarter Third Quarter Fourth Quarter Quarter Average Nuclide Number 01/03-04104 04104.07110 07/10-10/02 10102-01/02
+/- 1 std dev.
TLD 86 5.3 +/- 0.7 87 7.3 +/- 0.0 88 3.8 +/- 1.4 89 4.8 +/- 0.9 90 10.4 +/- 0.6 91 8.0 +/- 0.9 94 5.6 +/-0.1 4.7 +/- 0.9 6.4 +/- 0.4 7.5 +/- 0.9 2.2 +/- 0.1 4.0 +/- 1.0 2.3 +/- 0.0 7.1 +/-0.7 4.2 +/- 0.7 8.0 +/- 2.1 4.2 +/- 2.2 6.2 +/- 1.2 7.6 +/- 1.2 3.6 +/- 0.1 4.1 +/- 1.3 12.4 +/- 1.0 9.6 +/- 0.1 13.6 +/- 0.2 15.2 +/- 1.5 16.3 +/- 0.5 9.9 +/- 0.2 13.5 +/- 1.0 6.7 +/- 3.9 7.8 +/- 1.4 7.3 +/- 4.5 7.1 +/-5.6 9.6 +/- 5.2 6.0 +/- 3.6 7.6 +/-4.1 Average/Quarter Average/Day co Range w
Detection/Total 7.4 +/- 2.0 mrem/100 days 0.074 +/- 0.02 mrem/day (6.5-16.1) mrem/100 days 32/32 6.5 +/- 2.7 mrem/84 days 0.077 +/- 0.03 mrem/day (1.3-11.7) mrem/84 days 32/32 4.6 +/- 2.1 mremil39 days 0.033 +/- 0.01 mrem/day (6.5-14.2) mrem/139 days 32/32 12.1 +/-2.9 mrem/84days 0.144 +/- 0.03 mrem/day (8.2-20.6) mrem/84 days 32/32
vII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)
STATION NUMBER 28 DATE COLLECTED (a)
RADIOCHEMICAL ANALYSIS:
1-131 GAMMA SPECTRUM ANALYSIS:
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No vegetation sampled due to milk sample being available. Vegetation will be sampled if milk samples are not available.
VII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)
STATION NUMBER 35 DATE COLLECTED (a)
RADIOCHEMICAL ANALYSIS:
1-131 GAMMA SPECTRUM ANALYSIS:
BE-7 K-40 XD MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No vegetation sampled due to milk sample being available. Vegetation will be sampled if milk samples are not available.
vII-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCI/KG WET)
STATION NUMBER 96 DATE COLLECTED (a)
RADIOCHEMICAL ANALYSIS:
1-131 GAMMA SPECTRUM ANALYSIS:
BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No vegetation sampled due to milk sample being available. Vegetation will be sampled if milk samples are not available.
Vll-9 NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - INGESTION VEGETATION-TERRESTRIAL, BROADLEAF (PCIIKG WET)
STATION NUMBER 101 DATE COLLECTED (a)
RADIOCHEMICAL ANALYSIS:
1-131 GAMMA SPECTRUM ANALYSIS:
BE-7 K-40 co MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-1 34 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 (a) No vegetation sampled due to milk sample being available. Vegetation will be sampled if milk samples are not available.
vil-lo NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE SHORELINE SEDIMENT (PCIIKG DRY)
STATION NUMBER 28 DATE COLLECTED:
05/04/04 10104/04 GAMMA SPECTRUM ANALYSIS:
co co BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 4.E+02 1.46E+04 +/- 1.27E+03 L.T. 4.E+01 L.T. 3.E+01 L.T. 1.E+02 L.T. 3.E+01 L.T. 8.E+01 L.T. 7.E+01 L.T. 4.E+01 L.T. 4.E+02 L.T. 1.E+02 L.T. 4.E+01 7.90E+01 +/- 3.51 E+01 L.T. 3.E+02 L.T. 7.E+01 L.T. 2.E+02 L.T. 7.E+02 2.37E+03 +/- 8.78E+02 5.50E+02 +/- 3.39E+02 1.58E+04 +/- 1.15E+03 L.T. 3.E+01 L.T. 3.E+01 L.T. 7.E+01 L.T. 4.E+01 L.T. 6.E+01 L.T. 5.E+01 L.T. 3.E+01 L.T. 3.E+02 L.T. 6.E+01 L.T. 3.E+01 6.27E+01 +/- 3.62E+01 L.T. 1.E+02 L.T. 5.E+01 L.T. 2.E+02 1.95E+03 +/- 8.51E+02 2.61E+03 +/- 8.26E+02
vil-lo NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION EXPOSURE PATHWAY - AIRBORNE SHORELINE SEDIMENT (PCI/KG DRY)
STATION NUMBER 35 DATE COLLECTED:
05/04/04 10/04/04 GAMMA SPECTRUM ANALYSIS:
co BE-7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZR-95 RU-103 RU-106 1-131 CS-134 CS-137 BA-140 CE-141 CE-144 RA-226 TH-228 L.T. 4.E+02 1.52E+04 +/- 1.09E+03 L.T. 3.E+01 L.T. 3.E+01 L.T. 8.E+01 L.T. 3.E+01 L.T. 6.E+01 L.T. 6.E+01 L.T. 3.E+01 L.T. 3.E+02 L.T. 1.E+02 L.T. 3.E+01 L.T. 3.E+01 L.T. 2.E+02 L.T. 7.E+01 L.T. 2.E+02 L.T. 7.E+02 2.50E+03 +/- 9.66E+02 L.T. 1.E+02 5.06E+03 +/- 3.72E+02 L.T. 1.E+01 L.T. 1.E+01 L.T. 3.E+01 L.T. 1.E+01 L.T. 3.E+01 L.T. 2.E+01 L.T. 1.E+01 L.T. 1.E+02 L.T. 2.E+01 L.T. 1.E+01 L.T. 1.E+01 L.T. 6.E+01 L.T. 2.E+01 L.T. 7.E+01 4.24E+02 +/- 2.15E+02 5.88E+02 +/- 2.25E+02
SECTION VIII. REFERENCES 90
VIII. REFERENCES
- 1.
Nebraska Public Power District, Cooper Nuclear Station Environmental Radiation Monitoring Program, Annual Report, January 1, 1982-December 31, 1982 (prepared by Teledyne Isotopes).
- 2.
Nebraska Public Power District, Cooper Nuclear Station Environmental Radiation Monitoring Program, Annual Report, January 1, 1983-December 31, 1983 (prepared by Teledyne Isotopes).
- 3.
Nebraska Public Power District Cooper Nuclear Station, Environmental Monitoring Program, Annual Report, January 1, 1984 to December 31, 1984. (Prepared by Teledyne Isotopes).
- 4.
U.S. Department of Energy; EML 440 March 1985; EML-444 April 1989; Environmental Measurements Laboratory, US Department of Energy, New York, New York 10014.
- 5.
U.S. Environmental Protection Agency; Environmental Radiation Data, Report 35, July -- September 1983, Report 39, July -- September 1985; Report 40, October --
December 1984; Report 41, January -- March 1985. Report 42, April -- June 1985; Report 43, July-September 1985, Report 44-45, October-March 1986; Report 46, April-June 1986; Report 47, July-September 1986; Report 48, October-December 1986; Report 49, January-March 1987.
Environmental Radiation Facility, Montgomery, Alabama.
- 6.
U.S. Department of Energy; EML 460, October 1, 1986; Environmental Measurements Laboratory, US Department of Energy, New York, New York 10014.
- 7.
U.S. Nuclear Regulatory Commission, 1975, Regulatory Guide 4.8, Environmental Technical Specifications for Nuclear Power Plants.
- 8.
U.S. Regulatory Commission, Branch Technical Position, Radiological Monitoring Acceptable Program (November, 1979, Revision 1).
91
APPENDIX A 2004 LAND USE CENSUS A-1
2004 LAND USE CENSUS Conducted July 20, 2004 0-3 miles Cooper Nuclear Station (CNS) Offsite Dose Assessment Manual (ODAM) requires an annual land use census. This census identifies the location of the nearest garden that is greater than 500 square feet in area and yields leafy green vegetables, the nearest milk animal, and the location of the nearest resident in each of the 16 meteorological sectors within 3 miles of CNS.
A land use census was performed on July 20, 2004, in accordance with the CNS ODAM.
The nearest residence was found in sector Q, 0.9 miles from CNS, and the nearest garden was found in sector L, 1.3 miles from CNS.
No milk animals were found within 3 miles of CNS and there was no evidence of potable water use from the Missouri River within three miles downstream of CNS.
A-2
2004 LAND USE CENSUS July 20, 2004 0-3 Miles SECTOR NEAREST RESIDENT Direction NEAREST GARDEN Direction NEAREST in Degrees in Degrees MILK Distance Distance ANIMAL A/N 3.0 Miles 1.00 NONE NA NONE B/NNE NONE NA NONE NA NONE C/NE NONE NA NONE NA NONE D/ENE 1.7 Miles 62.00 2.8 Miles 70.00 NONE E/E 2.0 Miles 97.00 2.0 Miles 97.00 NONE F/ESE 2.3 Miles 112.00 2.3 Miles 112.00 NONE G/SE NONE NA 1.2 Miles 134.00 NONE H/SSE NONE NA NONE NA NONE J/S NONE NA NONE NA NONE K/SSW NONE NA NONE NA NONE L/SW 1.3 Miles 219.00 1.3 Miles 219.00 NONE M/WSW 1.3 Miles 253.00 1.9 Miles 241.00 NONE N/W 1.0 Miles 265.00 NONE NA NONE P/WNW 1.7 Miles 299.00 2.4 Miles 293.00 NONE Q/NW 0.9 Miles 307.0° 2.9 Miles 313.00 NONE R/NNW 1.9 Miles 339.0° 1.9 Miles 339.00 NONE A-3
APPENDIX B
SUMMARY
OF INTERLABORATORY COMPARISONS The Teledyne Brown Enzineerin2 ICP report is presented in this section B-1
INTERLABORA TORY COMPARISION PROGRAM The purpose of the Interlaboratory Comparison Program (ICP) is to confirm the accuracy of results produced by Teledyne Brown Engineering.
Samples of various matrices (i.e. soil, water, vegetation, air filters, and milk) are spiked with known amounts of radioactivity by commercial vendors of this service and by departments within the government. TBE participates in four programs. Two are commercial, Analytics Inc. and Environmental Resource Associates (ERA) and two are government sponsored programs, the Department of Energy's (DOE) Environmental Measurements Laboratory (EML) and the Mixed Analyte Performance Evaluation Program (MAPEP).
The DOE's Idaho National Engineering Laboratory administers the MAPEP. All four programs are blind performance evaluation studies in which samples with known activities are sent to TBE for analysis.
Once analyzed, TBE submits the results to the respective agency for evaluation. The results of these evaluations are published in TBE's quarterly and annual QA reports.
The 2004 Interlaboratory Comparison Program includes all contractually required matrices and analyses we supply to customers.
The US Environmental Protection Agency (EPA) discontinued their Interlaboratory Comparison Program in December 1998.
However, on May 1, 2001, accreditation was granted to Environmental Resource Associates' (ERA) RadCheM Proficiency Testing Program to complete the process of replacing the USEPA-LV Nuclear Radiation Assessment Division program.
The Department of Energy's Environmental Measurement Laboratory (EML) program terminated performance assessments at the end of the March 2004 test session.
The MAPEP sample distribution for July 2004 was expanded to include water, soil, and air particulate testing material previously provided by DOE/EML. Vegetation matrix samples will not be offered until the January 2005 test session.
The National Institute of Standards and Technology (NIST) is the approval authority for laboratory providers participating in Intercomparison Study Programs; however, at this time, there are no approved laboratories for environmental and/or radiochemical isotope analyses.
Trending graphs are provided in this section for the Analytics and ERA Programs.
B-2
ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 3)
Identification Reported Known Ratio (c)
Month/Year Number Matrix Nuclide Units Value (a) Value (b)
TBE/Analytics Evaluation (d)
November, 2003 E3970-396 Milk E3971-396 Milk Sr-89 Sr-90 1-131 Ce-141 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCi/L pCiUL pCiUL pCiUL pCi/L pCiUL pCiUL pCiUL pCiUL pCiUL pCiUL pCiUL 185 168 19 17 87 90 186 202 287 280 119 135 116 129 111 111 176 173 94 102 190 197 140 155 1.10 1.12 0.97 0.92 1.03 0.88 0.90 1.00 1.02 0.92 0.96 0.90 1.01 1.03 0.94 0.93 1.03 0.94 1.00 0.87 0.94 A
A A
A A
A A
A A
A A
A A
A A
A A
A A
A A
E3973-396 AP Ce-141 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCi 144 pCi 203 pCi 90 pCi 85 pCi 80 pCi 115 pCi 72 pCi 121 pCi 102 142 198 96 91 78 122 72 139 109 E3972-396 Charcoal 1-131 pCi 67 77 0.87 A
March, 2004 E4128-396 Milk Sr-89 Sr-90 pCi/L pCi[L 91 103 13 12 0.88 1.08 A
A E4129-396 Milk 1-131 Ce-141 Cr-51 Cs-1 34 Cs-1 37 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCiUL pCiUL pCUL pCiUL pCiL pCiUL pCiUL pCiUL pCiUL pCiUL 77 77 340 76 176 113 110 65 132 144 78 85 327 90 185 112 114 57 143 153 0.99 0.91 1.04 0.84 0.95 1.01 0.96 1.14 0.92 0.94 A
A A
A A
A A
A A
A E4131-396 AP Ce-141 Cr-51 Cs-134 Cs-I 37 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCi 87 pCi 325 pCi 87 pCi 185 pCi 117 pCi 105 pCi 59 pCi 179 pCi 145 88 338 93 192 116 118 59 148 159 0.99 0.96 0.94 0.96 1.01 0.89 1.00 1.21 0.91 A
A A
A A
A A
W A
B-3
ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 2 OF 3)
Identification Reported Known Ratio (c)
Month/Year Number Matrix Nuclide Units Value (a) Value (b)
TBE/Analytics Evaluation (d)
March, 2004 E4130-396 Charcoal 1-131 pCi 88 97 pCi/L 77.9 87.7 pCi/L 12.0 12.7 June, 2004 E4213-396 Milk E4214-396 Milk E4216-396 AP Sr-89 Sr-90 1-131 Ce-141 Cr-51 Cs-1 34 Cs-1 37 Co-58 Mn-54 Fe-59 Zn-65 Co-60 Ce-141 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCi/L pCUL pCUL pCUL pCVL pCiUL pCi/L pCiUL pCi/L pCiUL 53.7 58.2 145 157 212 228 85.2 101 145 156 45.7 46.2 68.2 70.5 44.4 44.5 102 99.3 162 172 pCi 116 118 pCi 160 172 pCi 68.6 76.3 pCi 108 118 pCi 33.1 39.4 pCi 51.1 53.3 pCi 44.0 33.6 pCi 69.1 75.1 pCi 123 130 pCi 71.8 82.0 pCi/L 93.9 102 pCi/L 24.0 24.5 0.91 0.89 0.95 0.92 0.92 0.93 0.84 0.93 0.99 0.97 1.00 1.03 0.94 0.98 0.93 0.90 0.92 0.84 0.96 1.31 0.92 0.95 0.88 0.92 0.98 0.98 0.91 0.93 0.85 0.95 0.97 0.96 1.02 1.00 0.92 A
A A
A A
A A
A A
A A
A A
A A
A A
A A
N (i)
A A
A A
A A
A A
A A
A A
A A
A E4215-396 Charcoal 1-131 September, 2004 E4323-396 Milk E4324-396 Milk Sr-89 Sr-90 1-131 Ce-141 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCi/L pCi/L pCiUL pCi/L pCi/L pCi/L pCi/L pCi/L pCUL pCi/L 81.9 83.5 214 235 196 210 77.3 90.6 192 202 86.2 89.0 163 171 87.4 86.1 168 167 108 118 B-4
ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 3 OF 3)
Identification Reported Known Ratio (c)
Month/Year Number Matrix Nuclide Units Value (a) Value (b) TBE/Analytics Evaluation (d)
September, 2004 E4326-396 AP Ce-141 Cr-51 Cs-1 34 Cs-1 37 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCi 149 pCi 122 pCi 50.3 pCi 112 pCi 54.8 pCi 102 pCi 47.6 pCi 111 pCi 69.0 148 132 57.1 127 56.0 108.0 54.2 106 74.1 1.01 0.92 0.88 0.88 0.98 0.95 0.88 1.05 0.93 A
A A
A A
A A
A A
E4325-396 Charcoal 1-131 pCi 70.3 74.9 0.94 A
October, 2004 E4407-396 Milk Sr-89 Sr-90 pCi/L 91.7 98.6 pCUL 11.9 11.3 0.93 1.05 A
A E4408-396 Milk 1-131 Ce-141 Cr-51 Cs-134 Cs-137 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCUL pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L 58.3 140 374 143 120 140 135 124 198 166 66.7 155 379 170 126 146 136 121 196 175 0.87 0.91 0.99 0.84 0.95 0.96 1.00 1.02 1.01 0.95 A
A A
A A
A A
A A
A E4410-396 AP Ce-141 Cr-51 Cs-134 Cs-1 37 Co-58 Mn-54 Fe-59 Zn-65 Co-60 pCi 77.0 79.1 pCi 156 187 pCi 76.6 83.5 pCi 58.9 62.0 pCi 68.6 71.8 pCi 63.2 66.7 pCi 65.2 59.7 pCi 99.7 96.3 pCi 80.1 85.9 pCi 80.9 83.3 0.97 0.84 0.92 0.95 0.96 0.95 1.09 1.04 0.93 0.97 A
A A
A A
A A
A A
A E4409A-396 Charcoal 1-131 (1) The Analytics filter had very low activity and was counted longer than two days. This resulted In poor accuracy as demonstrated by the very large error term. Dan Montgomery of Analytics concurred that, with the low counts and large error, the results were reasonably accurate andwouldnotbe considereda failedcross checkat 1.31 foran environmentallevelsample. NCR 04-16 (a) Teledyne Brown Engineering reported result.
(b) The Analytics known value Is equal to 100%0 of the parameter present In the standard as determined by gravimetric and/or volumetric measurements made during standard preparation.
(c) Ratio of Teledyne Brown Engineering to Analytics results.
(d) Analytics evaluation based on TBElntemalOClimtts:A= Acceptable. Reported result falls within ratio limits of 0.80-1.20.
W-Acceptable with waming. Reported result falls within.70-0.80 or 1.20-1.30. N = NotAcceptable. Reported result falls outside the ratio limits of < 0.70 and > 1.30.
B-5
DOE/EML ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 1)
Identification Reported Known Ratio (c)
Month/Year Number Media Nuclide Units Value (a) Value (b)
TBE/EML Evaluation (d)
AP Co-60 Sr-90 Cs-134 Cs-137 Gr-A Gr-B Soil K-40 Sr-90 Cs-137 Bi-212 Pb-212 Bi-214 Pb-214 Ac-228 Th-234 Bq/filter Bqlfilter Bq/filter Bq/filter Bq/filter Bq/filter Bq/kg Bq/kg Bq/kg Bq/kg Bq/kg Bq/kg Bq/kg Bqlkg Bq/kg 33.5 1.8 18.7 24.8 1.8 2.88 583 42.1 1429 52.6 50.1 57.6 61.4 49.4 114.9 35.4 1.76 18.2 26.4 1.2 2.85 539 51.0 1323 50.43 47.73 58.4 61.0 49.0 84.0 0.95 1.02 1.03 0.94 1.50 1.01 A
A A
A N (1)
A 1.08 0.83 1.08 1.04 1.05 0.99 1.01 1.01 1.37 A
A A
A A
A A
A A
Vegetation K-40 Bq/kg 807.5 720.0 1.12 Co-60 Bq/kg 14.2 14.47 0.98 Sr-90 Bq/kg 685 734.0 0.93 Cs-137 Bq/kg 637.3 584.67 1.09 Water Co-60 Bq/L 159.7 163.2 0.98 Sr-90 Bq/L 4.74 4.76 1.00 Cs-137 Bq/L 50.6 51.95 0.97 Gr-A Bq/L 394.0 326.0 1.21 Gr-B Bq/L 1200.0 1170.0 1.03 (1) Incorrect efficiency used. When recalculated with the correct efficiency, the Gross Alpha activity of 1.16 q/ifter compared well with the value of 1.2 Bq/fiter. NCR 04-14 (a) Teledyne Brown Engineering reported result (b) The DOEIEML known value Is equal to 100% of the parameterpresent In the standard as determined bygravimetric and/or volumetric measurements made during standard preparation.
(c) Ratio of Teledyne Brown Engineering to DOE/EML results.
(d) DOE/EML evaluation: A=acceptable, W-acceptable with warning, N=not acceptable.
A A
A A
A A
A W
A B-6
MAPEP ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 1)
Identification Reported Known Month/Year Number Media Nuclide Units Value (a) Value (b) Control Limits Evaluation (c)
January, 2004 July, 2004 03-W1I1 Water Cs-1 34 Cs-137 Co-57 Co-60 H-3 Mn-54 Sr-90 Zn-65 MaW12 Water Cs-134 Cs-137 Co-60 H-3 Mn-54 Sr-90 Zn-65 Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L Bq/L 289.1 118.7 164 121.1 425.3 152.6 16.4 303.3 177 237 160 109 262 6.79 217 322.0 124.0 173.0 121.8 379.0 155.0 17.7 320.0 208 250 163 82.9 267 7.4 208 225.40 - 418.60 86.80- 161.20 121.10 - 224.90 85.26-158.34 265.30 - 492.70 108.50 - 201.50 12.39 - 23.01 224.00 - 416.00 145.60 - 270.40 175.00 - 325.00 114.10 -211.90 58.10- 107.90 186.90 - 347.10 4.90 - 9.10 145.60 - 270.40 A
A A
A A
A A
A A
A A
N (1)
A A
A GrW12 Water Gr-A Gr-B RdF12 AP Cs-134 Cs-137 Co-60 Mn-54 Sr-90 Zn-65 Bq/L 0.836 1.24
>0.0 - 2.40 Bq/L 4.95 4.07 2.05 - 6.15 Bq/sample Bq/sample Bq/sample Bq/sample Bq/sample Bq/sample 2.19 1.87 2.28 3.06 0.909 4.53 2.9 1.96 2.35 3.03 0.83 4.11 2.03 - 3.77 1.40 - 2.60 1.61 - 2.99 2.10 - 3.90 0.56 - 1.04 2.80 - 5.20 A
A W
A A
A A
A A
A GrF12 AP Gr-A Gr-B Bq/sample 0.126 0.37
>0.0 - 0.80 Bq/sample 1.34 1.21 0.60- 1.80 MaS12 Soil Cs-134 Cs-137 Co-60 Mn-54 K-40 Zn-65 Bq/kg Bq/kg Bq/kg Bq/kg Bqlkg Bq/kg 327.7 786.0 509.3 477 609 727 414 836 518 485 604 699 290.08 - 538.72 585.34 - 1,088 362.60 - 673.40 339.29 - 630.11 422.80 - 785.20 489.51 - 909.09 W
A A
A A
A (1) All raw data looked normal for the sample. Evaluating the results based on the +/- 20 Bq/L uncertainty the result easily overlaps the known value at the 95% confidence level. The sample was rerun with a larger aliquot to improve accuracy and lower the uncertainty.
The H-3 result of 96.4 + 7.75 Bq/L was within the acceptance range. NCR 04-19 (a) Teledyne Brown Engineering reported result (b) The MAPEP known value Is equal to 100% of the parameter present In the standard as determined bygravimetric and/or volumetric measurements made during standard preparation.
(c) DOEIMAPEP evaluation: A=acceptable. W=acceptab/e with warning. N=not acceptable.
B-7
ERA ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE QC SPIKE PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES (PAGE 1 OF 1)
Identification Reported Known Month/Year Number Media Nuclide Units Value (a) Value (b)
Control Limits Evaluation (c)
May, 2004 Rad 57 Water Sr-89 Sr-90 Ba-133 Cs-1 34 Cs-1 37 Co-60 Zn-65 Gr-A Gr-B H-3 August, 2004 Rad 58 Water 1-131 pCi/L pCi/L pCi/L pCiUL pCi/L pCi/L pCi/L pCUL pCUL pCi/L 139 45.9 37.2 - 54.6 11.3 11.6 2.94 - 20.3 93.9 101 83.5-118 43.3 50.5 41.8 - 59.2 79.3 82.5 73.8 - 91.2 42.4 41.6 32.9 - 50.3 81.9 75.2 62.2 - 88.2 39.9 38.8 22.0 - 55.6 62.5 59.6 42.3 - 76.9 33500 30900 25600- 36200 N (1)
A A
A A
A A
A A
A A
pCi/L 9.09 9.29 5.83 - 12.8 December, 2004 Rad 59 Water Sr-89 Sr-90 Ba-133 Cs-134 Cs-137 Co-60 Zn-65 Gr-A Gr-B 1-131 H-3 pCi/L pCUL pCUL pCUL pCUL pCUL pCUL pCi/L pCi/L pCi/L pCi/L 44.0 45.7 37.0 - 54.4 35.3 36.6 27.9 - 45.3 73.9 78.4 64.8 - 92.0 37.8 42.9 34.2 - 51.6 58.3 60.1 51.4 - 68.8 11.5 11.7 3.04 - 20.4 51.3 50.9 42.1 - 59.7 23.9 31.7 18.0-45.4 33.9 36.3 27.6 - 45.0 19.2 22.1 16.9 - 27.3 22900 20700 17100 - 24300 A
A A
A A
A A
W A
A A
(1) The strontium-89 mount was counted without the absorber. When recounted using the absorber the Sr-89 result of4l.5 pCLL agreed well with the ERA known value of 45.9 pCilL NCR 04-13 (a) Teledyne Brown Engineering reported result.
(b) The ERA known value Is equal to 1000/0 of the parameterpresent In the standard as determined by gravimetric and/or volumetric measurements made during standard preparation.
(c) ERA evaluation: A=acceptable. Reported result falls within the Warning Limits. NA=not acceptable. Reported result falls outside of the Control imits. CE=check for Error. Reported result falls within the Control Limits and outside of the Warning Limit.
B-8
INTERLABORATORY COMPARISON PROGRAM GRAPHS 1-131 IN MILK 120 -
100 L.80-me A
- 60 l
Q.
40 20 0
Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l TBE
- Analytics Ce-141 IN MILK 1000 800 a)
-J 0
0.
U 600 -
a 400 -
v 0
m 200-a I U
4 I'-
m U a
as*
a a
U J -98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04
- r. TBE
- Analytics Cr-51 IN MILK 1200 -
1000 --
O 800 -
C)
J 600 -
l 2400 -
0 Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04
- TBE
- Analytics B-9
INTERLABORATORY COMPARISON PROGRAM GRAPHS Cs-134 IN MILK 300 -
225 -
75 -
0-Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l TBE
- Analytics Cs-137 IN MILK 350 300 -
a 250 -
200 a100 50 0
Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04
- TBE P Analytics Mn-54 IN MILK 240 -
200- -
.° 160 -
120 -
80 -
40 -
Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l TBE
- Analytics B-1 0
INTERLABORATORY COMPARISON PROGRAM GRAPHS Fe-59 IN MILK 180 160 -
140 -
O120 -
100*
% 80 60 h
40 -
20 Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l
- TBE
- Analytics Zn-65 IN MILK 350 300
'-250 S
200 -*
a150 -
a 100 50 Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l* TBE
- Analytics Co-60 IN MILK 400 -
350 -
300 -
250 -
I 200 A
150 -
a A
100 50 Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l
- TBE
- Analytics l B-11
INTERLABORATORY COMPARISON PROGRAM GRAPHS Sr-90 IN MILK 80 -
60 -
~40 -
m 0
20 Q20l
- is Jul-98 Jul-99 Jul-00 Jul-01 Jul-02 Jun-03 Jun-04 l TBE
- Analyticsl Co-58 in Milk 200 -
U 160-120 -
080 h
40 S
0 Oct-00 Mar-01 Sep-01 Mar-02 Sep-02 Mar-03 Sep-03 Mar-04 Sep-04 l TBE
- Analyticsl Sr-89 IN MILK 200 180.
160 -
140 -
° 120
__100 80 60 40 20 0
Dec-99 Jun-00 Jan-01 Jul-01 Feb-02 Sep-02 Mar-03 Oct-03 Apr-04 Nov-04 l TBE
- Analytics B-1 2
INTERLABORATORY COMPARISON PROGRAM GRAPHS Ce-141 IN FILTERS 690 -
590 -
490 -
- 0. 390-co290 F-190 l
0 90J-D D
D Nov-04 I I
I Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l* TBE
- Analyticsl Cr-51 IN FILTERS 890 790 690 -
590 m 490 390 -
I I-290-190 I
l a
90 p
-10 Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l TBE
- Analytics Cs-134 IN FILTERS 170 -
150 -
130 -
5 110-
- 0. 90-W 70-1 50-30 -
10 - Jar I
0
- he a-U.
p p U.
I m
- ^ *-
- 5 I I
I
- ~*
I i-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l* TBE
- Analytics B-1 3
INTERLABORATORY COMPARISON PROGRAM GRAPHS Cs-137 IN FILTERS 440 -
j3 290-0.
i-140 --
a a
-10I I
Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l TBE
- Analytics Mn-54 IN FILTERS 190 150 -
o.
1 1 0 X
I 0 70 30
-10 Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l*TBE
- Analytics Fe-59 IN FILTERS 190 170 150 130 -
10 10 90 -
7O 50a 30 10
-10 Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04 l TBE
- Analytics B-14
INTERLABORATORY COMPARISON PROGRAM GRAPHS Zn-65 IN FILTERS 290 240 -
- c. 190-140-90 40 Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04
- TBE
- Analytics Co-60 IN FILTERS 290 240 -
a 190
- 0.
m I
-a 14 0 -*
o a w
- a a.s 90 90 40
-10 I
I Jan-98 Dec-98 Dec-99 Dec-00 Dec-01 Dec-02 Dec-03 Nov-04
- TBE
- Analytics Co-58 IN FILTERS 240 -
190 -
a o
140-0 90-i p 40 4
-10 Mar-00 Mar-01 Feb-02 Feb-03 Feb-04 Feb-05
- TBE
- Analytics B-15
INTERLABORATORY COMPARISON PROGRAM GRAPHS 1-131 IN CHARCOAL CARTRIDGE
---7 1 000 -
100 V-1mi
-- w CL 3§ 10 0
-0 w - w 1111 1111 1
0.1 7_7_-'_,_v_
Dec-99 Jun-00 Jan-01 Jul-01 Feb-02 Sep-02 Mar-03 Oct-03 Apr-04 Nov-04
- TBE Analytics B-16 C-0)
INTERLABORATORY COMPARISON PROGRAM GRAPHS 1-131 IN WATER 1000 -
100 CD
-a 1 0 9-0.1 Apr-01 Nov-01 May-02 Dec-02 Jun-03 U
I I
jU Jan-04 Aug-04 Feb-05
- TBE HERA Co-60 IN WATER 140 -
120 -
100 -
2 80 6
60 40 ---
l I
a 4,\\zu 0
,-9--
0 O-A 1
J Aug-99 Mar-00 Oct-00 Apr-01 Nov-01 May-02 Dec-02 Jun-03 Jan-04 Aug-04 Feb-OS
- L____,
- TBE
- ERA Cs-134 IN WATER 80 70 C_--_-_.__
60 50:
40 0L) 30 0
Aug-99 Mar-00 Oct-00 Apr-01 Nov-01 May-02 Dec-02 Jun-03 Jan-04 Aug-04 Feb-05
- TBE HERA B-17 CO 1
INTERLABORATORY COMPARISON PROGRAM GRAPHS Cs-137 IN WATER 250 200 150 C) 100 50 U
0 Aug-99 Mar-00 Oct-00 Apr-01 Nov-01 May-02 Dec-02 Jun-03 Jan-04 Aug-04 Feb-05
- TBE MERA February 2001 - Analyst error or equipment failure.
Sr-89 IN WATER 160 130
,9 100 o
70-C-
40 11
,.I
_ ~
Dec-99 Jun-00 Nov-00 May-01 Nov-01 May-02 Nov-02 May-03 Nov-03 May-04 Nov-04
- OTBE HERA May 2004 - Counted without absorber.
Sr-90 IN WATER 40 -
If 30 tT 1 20 -
C-1 0
~
U
__'-I I
U 0
L- -
I_._
Dec-99 Jun-00 Jan-01 Jul-01 Feb-02 Sep-02 Mar-03 Oct-03 Apr-04 Nov-04
- TBE HERA B-1 8 cY-(Z
Ba-133 IN WATER 120 100 80 60 r
40 20 0-=
Aug-99 Mar-00 Oct-00 Apr-01 Nov-01 May-02 Dec-02 Jun-03 Jan-04 Aug-04 Feb-05 I-
- TBE EERA Zn-65 IN WATER 100 -r_
70 CL 40--
U 10 Dec-99 Jun-00 Nov-00 May-01 Nov-01 May-02 Nov-02 May-03 Nov-03 May-04 Nov-04
- TBE
- ERA]
GROSS ALPHA IN WATER 90 80 70 60 60 50 3
50-40
=
30 20 Dec-99 Jun-00 Jan-01 Jul-01 Feb-02 Sep-02 Mar-03 Oct-03 Apr-04 Nov-04
- TBE
.ERA February 2000 - Analyst error or equipment failure.
B-1 9 CU'
INTERLABORATORY COMPARISON PROGRAM GRAPHS 70 60 50 -_
40 C) rL 30 20 10 Dec-99 Jun-00 GROSS BETA IN WATER U
if Jan-01 Jul-01 Feb-02 Sep-02 Mar-03 Oct-03 Apr-04 Nov-04
- TBE
100 10 a
a I
I U
l
--=
May-99 Mar-00 Jan-01 Nov-01 Sep-02
- TBE H ERA Jun-03 Apr-04 Feb-05 B-20 cl-
APPENDIX C SYNOPSIS OF ANALYTICAL PROCEDURES C-1
ANALYTICAL PROCEDURES SYNOPSIS Appendix C is a synopsis of the analytical procedures performed during 2004 on samples collected for the Nebraska Public Power Nuclear Plant's Radiological Environmental Monitoring Program. All analyses have been mutually agreed upon by Nebraska Public Power District and Teledyne Brown Engineering and include those recommended by the USNRC Branch Technical Position, Rev. 1, November 1979.
ANALYSIS TITLE PAGE Gross Beta Analysis of Air Particulate Samples......................................
C-3 Air Particulates......................................
C-3 Determination of Gross Beta Activity in Water Samples......................................
C-4 Introduction........................................
C-4 Detection Capabilities......................................
C-4 Analysis of Samples for Tritium (Liquid Scintillation)......................................
C-5 Water......................................
C-5 Analysis of Samples for Iodine-1 31.......................................
C-6 Milk or Water......................................
C-6 Gamma Spectrometry of Samples........................................
C-7 Milk or Water......................................
C-7 Dried Solids other than Soils and Sediment........................................ C-7 Fish........................................
C-7 Soils and Sediments......................................
C-7 Charcoal Cartridges (Air Iodine)........................................
C-7 Airborne Particulates........................................
C-8 Addendum to Gamma Spectrometry Procedure........................................
C-9 Environmental Dosimetry......................................
C-10 Lower Limit of Detection Formulas........................................
C-I I C-2
GROSS BETA ANALYSIS OF AIR PARTICULATE SAMPLES Air Particulates After a delay of five or more days, allowing for the radon-222 and radon-220 (thoron) daughter products to decay, the filters are counted in a gas-flow proportional counter.
Calculations of the results, the two sigma error and the lower limit of detection (LLD):
RESULT (pCi/rn)
TWO SIGMA ERROR (pCi/mr)
LLD (pCi/rn)
=
((S/T) - (B/t))/(2.22 V E)
=
2((S/T ) + (B/t 2))1/ 2 /(2.22 V E) 1/2
=
4.66(B )/(2.22 V E t) where:
S
=
Gross counts of sample including blank B
=
Counts of blank E
=
Counting efficiency T
=
Number of minutes sample was counted t
=
Number of minutes blank was counted V
=
Sample aliquot size (cubic meters)
C-3
DETERMINATION OF GROSS BETA ACTIVITY IN WATER SAMPLES Introduction The procedures described in this section are used to measure the overall radioactivity of water samples without identifying the radioactive species present. No chemical separation techniques are involved.
One liter of the sample is evaporated on a hot plate. A smaller volume may be used if the sample has a significant salt content as measured gravimetrically. If requested by the customer, the sample is filtered through No. 54 filter paper before evaporation, removing particles greater than 30 microns in size.
After evaporating to a small volume in a beaker, the sample is rinsed into a 2-inch diameter stainless steel planchette, which is stamped with a concentric ring pattern to distribute residue evenly. Final evaporation to dryness takes place under heat lamps.
Residue mass is determined by weighing the planchette before and after mounting the sample. The planchette is counted for beta activity on an automatic proportional counter. Results are calculated using empirical self-absorption curves which allow for the change in effective counting efficiency caused by the residue mass.
Detection Capability Detection capability depends upon the sample volume actually represented on the planchette, the background and the efficiency of the counting instrument, and upon self-absorption of beta particles by the mounted sample. Because the radioactive species are not identified, no decay corrections are made and the reported activity refers to the counting time.
The minimum detectable level (MDL) for water samples is nominally 1.6 picoCuries per liter for gross beta at the 4.66 sigma level (1.0 pCi/L at the 2.83 sigma level), assuming that I liter of sample is used and that 1/2 gram of sample residue is mounted on the planchette. These figures are based upon a counting time of 50 minutes and upon representative values of counting efficiency and background of 0.2 and 1.2 cpm, respectively The MDL becomes significantly lower as the mount weight decreases because of reduced self-absorption. At a zero mount weight, the 4.66 sigma MDL for gross beta is 0.9 picoCuries per liter. These values reflect a beta counting efficiency of 0.38.
C-4
ANALYSIS OF SAMPLES FOR TRITIUM (Liquid Scintillation)
Water Ten milliliters of water are mixed with 10 ml of a liquid scintillation "cocktail" and then the mixture is counted in an automatic liquid scintillator.
Calculation of the results, the two sigma error and the lower limit detection (LLD) in pCi/L:
RESULT
=
(N-B)/(2.22 V E)
TWO SIGMA ERROR
=
2((N + B)/At)" 2/ (2.22 V E)
=
4.66(B/At) /(2.22 V E )
where:
N the gross cpm of the sample B
=
the background of the detector in cpm 2.22
=
conversion factor changing dpm to pCi V
=
volume of the sample in ml E
=
efficiency of the detector At
=
counting time for the sample C-5
ANALYSIS OF SAMPLES FOR IODINE-131 Milk or Water Two or more liters of sample are first equilibrated with stable iodide carrier. A batch treatment with anion exchange resin is used to remove iodine from the sample. The iodine is then stripped from the resin with sodium hypochlorite solution, is reduced with hydroxylamine hydrochloride and is extracted into carbon tetrachloride as free iodine. It is then back-extracted as iodide into sodium bisulfite solution and is precipitated as palladium iodide. The precipitate is weighed for chemical yield and is mounted on a nylon planchette for low-level beta counting.
Calculations of results, two sigma error and the lower limit of detection (LLD) in pCi/L:
RESULT
=
(N/At-B)/(2.22 E V Y DF)
TWO SIGMA ERROR
=
2((N/At+B)/At) /(2.22 E V Y DF) 112 LLD
=
4.66(B/At) /(2.22 E V Y DF) where:
N
=
total counts from sample (counts)
At
=
counting time for sample (min)
B
=
background rate of counter (cpm) 2.22 dpm/pCi V
=
volume or weight of sample analyzed Y
=
chemical yield of the mount or sample counted DF
=
decay factor from the collection to the counting date E
=
efficiency of the counter for I-13 1, corrected for self absorption effects by the formula E
=
Es(exp-0.0061M)/(exp-0.0061M s)
Es
=
efficiency of the counter determined from an 1-1 31 standard mount Ms
=
mass of Pdl 2 on the standard mount, mg M
=
mass of PdI2 on the sample mount, mg C-6
GAMMA SPECTROMETRY OF SAMPLES Milk or Water A 1.0 liter Marinelli beaker is filled with a representative aliquot of the sample.
The sample is then counted for approximately 1000 minutes with a shielded high purity germanium (HPGe) detector coupled to a VAX-based data acquisition system, which performs pulse height analysis.
Dried Solids other than Soils and Sediments A large quantity of the sample is dried at a low temperature, less than 1000C. As much as possible (up to the total sample) is loaded into a tared 1-liter Marinelli and weighed. The sample is then counted for approximately 1000 minutes with a shielded HPGe detector coupled to a VAX-based data acquisition system, which performs pulse height analysis.
Fish As much as possible (up to the total sample) of the edible portion of the sample is loaded into a tared Marinelli and weighed. The sample is then counted for approximately 1000 minutes with a shielded HPGe detector coupled to a VAX-based data acquisition system, which performs pulse height analysis.
Soils and Sediments Soils and sediments are dried at a low temperature, less than 1000C. The soil or sediment is loaded fully into a tared, standard 300 cc container and weighed. The sample is then counted for approximately six hours with a shielded HPGe detector coupled to a VAX-based data acquisition system, which performs pulse height and analysis.
Charcoal Cartridges (Air Iodine)
Charcoal cartridges are counted up to five at a time, with one positioned on the face of an HPGe detector and up to four on the side of the HPGe detector. Each HPGe detector is calibrated for both positions. The detection limit for I-131 of each charcoal cartridge can be determined (assuming no positive I-131) uniquely from the volume of air, which passed through it. In the event 1-131 is observed in the initial counting of a set, each charcoal cartridge is then counted separately, positioned on the face of the detector.
C-7
Air Particulates The thirteen airborne particulate filters for a quarterly composite for each field station are aligned one in front of another and then counted for at least six hours with a shielded HPGe detector coupled to a VAX-based data acquisition system which performs pulse height analysis.
A VAX software program defines peaks by certain changes in the slope of the spectrum. The program also compares the energy of each peak with a library of peaks for isotope identification and then performs the radioactivity calculation using the appropriate fractional gamma ray abundance, half-life, detector efficiency, and net counts in the peak region.
The calculation of results, two sigma error and the lower limit of detection (LLD) in pCi/volume or pCi/mass:
RESULT
=
(S-B)/(2.22 t E V F DF)
TWO SIGMA ERROR
=
2(S+B) /(2.22 t E V F DF)
=
4.66(B) /(2.22 t E V F DF) where:
S
=
Area, in counts, of sample peak and background (region of spectrum of interest)
B
=
Background area, in counts, under sample peak, determined by a linear interpolation of the representative backgrounds on either side of the peak t
=
length of time in minutes the sample was counted 2.22
=
dpm/pCi E
=
detector efficiency for energy of interest and geometry of sample V
=
sample aliquot size (liters, cubic meters, kilograms, or grams)
F
=
fractional gamma abundance (specific for each emitted gamma)
=
decay factor from the mid-collection date to the counting date C-8
ADDENDUM TO GAMMA SPECTROMETRY PROCEDURE Ba-140 (half-life =-12.8d) decays to LA-140 (half-life -40 hrs) and the daughter radionuclide, La-140 approaches - 90 % of the Ba-140 activity within - 6 days. The La-140 photon energy at 1596 keV is used to quantify the Ba-140 activity due to its high photon emission probability yield (96%) producing a higher count rate when present and therefore, a smaller associated counting error.
Zr-95 (half-life = -65d) decays to Nb-95 (half-life = -35d). The photon energy of Nb-95 (-765 keV) is used to quantify Zr-95 because of the high photon emission probability yield (-100%) yielding a higher count rate and an associated lower counting error. The daughter radionuclide, Nb-95 approaches the Zr-95 activity after a time period of-65 days, an estimated time interval occurring between sample exposure, collection and shipping, and analysis.
C-9
ENVIRONMENTAL DOSIMETRY Environmental Dosimetry services are provided by Proxtronics Dosimetry LLC, a Wholly Owned Subsidiary of Proxtronics, Inc. Proxtronics uses a thermoluminescent dosimeter (TLD) manufactured by Panasonic, Inc. Panasonic identifies it as an UD-814A1 1 TLD. The TLD has four elements, numbered 1-4. Elements and their filtration are composed of:
ELEMENT MATERIAL FILTRATION 1
nLi2nB4O7-Cu Thin plastic 2
CaSo4-Tm Plastic 3
CaSo4-Tm/Pb Lead 4
CaSo4-Tm/Pb 1 Lead This material has a high light output, negligible thermally induced signal loss (fading) and negligible self-dosing. The energy response curve (as well as other features) satisfies NRC Regulatory Guide 4.13. Transit doses are accounted for by use of separate TLDs.
Prior to being sent to Cooper Nuclear Station, the Proxtronics badges are exposed to Cs-137, to a known dose and read in the Panasonic UD-710 reader, with reference badges to establish an element response level for each badge. Badges are then re-annealed for assignment and distribution to Cooper Nuclear Station.
Following the field exposure the badges are returned to Proxtronics for processing in a Panasonic UD-710 reader. Each element is heated and the measured light emission is recorded. The transit controls are read in the same manner.
Transit Controls are calculated using the following equation:
T S(E3[
+ E41 + E32 + E4,) j -
[E3n e4.n TRANSDOSE=
l_4 J2 C-10
LOWER LIMIT of DETECTION FORMULAS The LLD formulas in Section C are consistent with the LLD discussion in the ODAM. The term Sb in the ODAM equals 4B/t by Poisson statistics, where B = blank counts and t = blank counting intervals. The decay factor term e~At in the ODAM is the same as the DF terms in Section C, but does not appear in certain analyses such as gross beta because decay does not apply. In the tritium analysis, decay is not considered because of the relatively long half-life.
Efficiencies and volumes are consistent between the two documents. Chemical yields appear in Section C where applicable but do not apply to other analyses such as tritium and gross beta.
C-1 I
APPENDIX D DETECTION LIMITS AND REPORTING LEVELS D-1
NEBRASKA PUBLIC POWER - COOPER NUCLEAR STATION DETECTION LIMITS AND REPORTING LEVELS Isotope ODAM LLD NRC Rept. Level Water - DCifliter Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-95 Nb-95 1-131 Cs-1 34 Cs-1 37 Ba-140 La-140 4
2000 15 30 15 15 30 30 15 1 (C) 15 18 60 15 N/A 20000a) /30000(b 1000 400 1000 300 300 400 400 2
30 50 200 200 Air Filter - pCI/m3 Gross Beta 1-131 Cs-1 34 Cs-1 37 0.01 0.07 0.05 0.06 N/A 0.9 10 20 Fish - PCI/kq-wet Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-1 34 Cs-137 130 260 130 130 260 130 150 30000 10000 30000 10000 20000 1000 2000 Milk - pCi/Iiter 1-131 Cs-1 34 Cs-1 37 Ba-140 La-140 I
15 18 60 15 3
60 70 300 300 (a) For drinking water samples (b) For samples of water not used as a source of drinking water (c) LLD for drinking water D-2
NEBRASKA PUBLIC POWER - COOPER NUCLEAR STATION DETECTION LIMITS AND REPORTING LEVELS Isotope ODAM LLD NRC Rept. Level Vegetation - PCI/kn-wet 1-131 Cs-1 34 Cs-1 37 Sediment - PCilkg-drv Cs-1 34 Cs-1 37 60 60 80 100 1000 2000 150 180 N/A N/A D-3
APPENDIX E REMP SAMPLING AND ANALYTICAL EXCEPTIONS E-1
EXCEPTIONS Appendix E contains the exceptions to the 2004 REMP Program. Where possible, causes of the deviation have been corrected to prevent recurrence.
Any deviations from the sampling schedule are documented on the data tables.
Data Tables are in Section VII.
E-2
Exceptions for Scheduled REMP Sampling and Analysis During 2004, NPPD Cooper Nuclear Station There were no exceptions to the program during 2004.
APPENDIX F
SUMMARY
OF DOSES TO A MEMBER OF THE PUBLIC OFFSITE Fl
LIQUID EFFLUENT DOSE CALCULATIONS Doses to the maximum individual and 0 to 50 - mile population resulting from the release of radioactive material in liquid effluents from Cooper Nuclear Station were calculated using the LADTAP II computer program. The LADTAP II program implements the radiological dose models of Regulatory Guide 1.109 for determining the radiation exposure to man from three principal exposure pathways in the aquatic environment -- potable water, aquatic foods, and recreational water use. Doses to both the maximum individual and 0 to 50 mile population are calculated as a function of age group and pathway for significant body organs, and are presented in Tables I - 6.
Assumptions and data sources used for input to the LADTAP II code are described in a separate section of this appendix (see page F5 1).
Note: There were no releases of radioactive material in liquid effluents from Copper Nuclear Station in 2004.
F2
TABLE 1. Doses to Maximum Individual at the Site Boundary, Resulting From Exposure to Radioactivity Discharged in Liquid Effluents, January-June 2004 Cooper Nuclear Station Dose to Individual, mrem Period and Pathway Total Body Skin Bone Liver Thyroid Kidney Lung GI-LLI 1st Quarter Drinking Water Shoreline 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals 2nd Quarter 171 Eating Fish Drinking Water Shoreline Totals Totals for 1st & 2nd Quarters 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Calculated doses are based on the following periods of exposures: Fishing: April - November; Drinking water and shoreline:
January - December
TABLE 2. Doses to Maximum Individual at the Site Boundary, Resulting From Exposure to Radioactivity Discharged in Liquid Effluents, July-December 2004, Cooper Nuclear Station Dose to Individual, mrem Period and Pathway Total Body Skin Bone Liver Thyroid Kidney Lung GI-LLI 3rd Quarter Eating Fish Drinking Water Shoreline Totals 4th 111 Quarter Eating Fish Drinking Water Shoreline Totals Totals for 3rd & 4th Quarters 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E. 00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Calculated doses are based on the following periods of exposures:
Fishing: April - November; Drinking water and shoreline: January -- December
TABLE 3.
Summary of Doses to Maximum Individual at the Site Boundary, Resulting from Exposure to Radioactivity Discharged in Liquid Effluents, January-December 2004, Cooper Nuclear Station Dose to Individual, mrem Period and Total Pathway Skin Bone Liver Body Thyroid Kidney Lung GI-LLI 1st Quarter 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 2nd Quarter 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+0O 0.00 E+00 0.00 E+00 3rd Quarter 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 4th Quarter 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals for 2004 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00
TABLE 4. Doses to Population Within a 50-Mile Radius, Resulting From Exposure to Radioactivity Discharged in Liquid Effluents, January-June 2004, Cooper Nuclear Station Dose to Population, manrem Period and Pathway Total Body Skin Bone Liver Thyroid Kidney Lung GI-LLI 1st Quarter Drinking Water Shoreline Totals 2nd Quarter 12 Eating Fish 0ci Drinking Water Shoreline Swimming Boating Totals Totals for 1st & 2nd Quarters 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 Z+00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+g.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 Z+00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 E+00 0.00 Z+00 0.00 E+00 0.00 E+00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 E+00 E+00 E+00 E+00 E+00 0.00 0.00 0.00 0.00 E+00 E+00 E+00 EOO0 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Calculated doses are based on the following periods of exposures: Fishing and Boating: April - November; Drinking water and shoreline:
January - December; Swimming: June - September Exposure from drinking water is calculated for the city of St. Joseph, Missouri, nearest public water intake from the Missouri River, 84 miles downstream
TABLE 5. Doses to Population Within a 50-Mile Radius, Resulting From Exposure to Radioactivity Discharged in Liquid Effluents, July-December 2004, Cooper Nuclear Station Dose to Population, manrem Period and Pathway Total Body Skin Bone Liver Thyroid Kidney Lung GI-LLI 3rd Quarter Eating Fish Drinking Water Shoreline Swimming e1d Boating 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 0.00 0.00 0.00 E+00 E+00 E+00 Totals 4th Quarter Eating Fish Drinking Water Shoreline 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 0.00 E+00 E+00 0.00 0.00 E+00 E+00 0.00 0.00 E+00 E+00 0.00 0.00 E+00 E+00 0.00 0.00 E+00 E+00 0.00 0.00 E+00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Totals for 3rd & 4th Quarters 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 Calculated doses are based on the following periods of exposures: Fishing and Boating: April -
November; Drinking water and shoreline:
January - December; Swimming: June -
September Exposure from drinking water is calculated for the city of St. Joseph, Missouri, nearest public water intake from the Missouri River, 84 miles downstream
TABLE 6. Summary of Doses to Population Within a 50-Mile Radius, Resulting from Exposure to Radioactivity Discharged in Liquid Effluents, January-December 2004, Cooper Nuclear Station Dose to Population, manrem Period and Pathway Skin Bone Total Liver Body Thyroid Kidney Lung GI-LLI 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter 00 Totals for 2004 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00 0.00 E+00
GASEOUS EFFLUENT DOSE CALCULATIONS Doses to the maximum individual and 0 to 50 mile population resulting from the release of radioactive material in gaseous effluents from the Cooper Nuclear Station were calculated using the GASPAR computer code. Four sites were selected for individual dose calculations: the site boundary, the nearest residence, the nearest garden and the nearest cow. GASPAR implements the radiological dose models of Regulatory Guide 1.109 for determining the radiation exposure to man from four principal atmospheric exposure pathways: plume, ground, inhalation, and ingestion. Doses to the maximum individual and the population are calculated as a function of age group and pathway for significant body organs.
Tables 1 through 7 present maximum individual doses. Population doses are given in Tables 8 through 14.
Assumptions and data used for input to the GASPAR code are described in a separate section of this appendix (see page F51).
F9
TABLE 1.
DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-MARCH 2004 SPECIAL LOCATION NO.
1 A Site Boundary AT
.69 MILES NNW ANNUAL BETA AIR DOSE = 3.14E-04 MILLRADS ANNUAL GAMMA AIR DOSE a 2.92E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
PLUME
- 1.96E-04 : 1.96E-04 : 1.96E-04 : 1.96E-04 : 1.96E-04 : 1.96E-04 : 1.99E-04 : 5.15E-04
________-+__________+__________+__________+_________+__________+__________+_--4________+-_______+
GROUND
- 3.11E-06 : 3.11E-06 : 3.11E-06 : 3.11E-06 : 3.11E-06 : 3.11E-06 : 3.11E-06 : 3.65E-06
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT
- 1.48E-05 2.45E-05 1.33E-04 1.99E-05 3.39E-05 6.42E-03 2.06E-08 0.OOE+00
________+-_________+_______-__+________-_+__________-4_____-___+_________-+__________+______-__-_
TEEN
- 2.17E-05 : 2.95E-05 : 2.19E-04 : 3.OOE-05 : 5.13E-05 : 8.65E-03 : 3.85E-08 : 0.OOE+00
_________+-_________+_________-_+__________+___--____+__________+__________+__________+__-__--____
CHILD
- 4.22E-05 : 2.33E-05 : 5.30E-04 : 5.08E-05 : 8.27E-05 : 1.66E-02 : 5.86E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT 3.45E-07
- 3.39E-07 1.55E-06 5.42E-07 9.09E-07 1.73E-04 s 1.67E-09 :0.00E+00
_________+__________+__________+__________+___-_-
-_____+__________+__________+_______---
TEEN
- 2.63E-07 : 2.10E-07 : 1.30E-06 : 4.41E-07 : 7.42E-07 : 1.25E-04 : 1.58E-09 : 0.OOE+00
_________+__________+_____---____+__________+_________+__________+__________+__--_-_--__________+
CHILD
- 3.80E-07 : 1.28E-07 : 2.44E-06 : 5.87E-07 : 9.43E-07 : 1.89E-04 : 1.86E-09 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
I ADULT
- 8.69E-06 5.08E-06 1.61E-05 1.51E-05 : 2.57E-05 : 4.82E-03 1.41E-08 0.OOE+00 o--
+-+-
-_____+________+_______-+
TEEN
- 1.45E-05 : 6.86E-06 : 2.92E-05 : 2.67E-05 : 4.58E-05 : 7.63E-03 : 2.91E-08 : 0.OOE+00 s
_________+____-___-___+________+__________+__________+__-4.-4.-_+_________-+__________+______-__-_
CHILD
- 2.68E-05 : 5.49E-06 : 7.13E-05 : 4.66E-05 : 7.61E-05 : 1.51E-02 : 4.48E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________-+_-________+_-____-___
INFANT : 5.07E-05 : 5.44E-06 : 1.44E-04 : 1.14E-04 : 1.32E-04 : 3.67E-02 : 8.10E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK:
ADULT
- 1.07E-05 6.86E-06 : 2.44E-05 : 1.83E-05 3.09E-05 5.79E-03 : 4.23E-08 : 0.OOE+00
_________+-__-______+__________+__-__-____+________-_+__________+__________+__________+__-_---____
TEEN
- 1.77E-05 : 9.28E-06 : 4.45E-05 : 3.25E-05 : 5.50E-05 : 9.16E-03 : 8.74E-08 : 0.00E+00
_________+______-___+_________-_+_____-___+__________+-__________+__________+_-4-_____+_________+-
CHILD s 3.29E-05 : 7.43E-06 : 1.09E-04 : 5.66E-05 : 9.15E-05 : 1.81E-02 : 1.34E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________-+_-________+_-____-___
INFANT : 6.21E-05 : 7.38E-06 : 2.16E-04 : 1.38E-04 : 1.59E-04 : 4.41E-02 : 2.43E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL I :
- I ADULT
- 9.53E-07 3.21E-06 : 1.85E-06 : 2.02E-06 3.47E-06 5.17E-04 1.03E-05 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+_--+-_______+_________
TEEN
- 1.25E-06 : 1.49E-05 : 2.61E-06 : 2.78E-06 : 4.79E-06 : 6.50E-04 t 1.76E-05 : 0.OOE+00
_________+ ______
___+__
+_____
____+
__+___
___+_--+________+-________
CHILD
- 1.37E-06 : 1.21E-04 : 3.56E-06 : 2.73E-06 : 4.50E-06 : 7.55E-04 : 1.58E-05 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+_--________+__________
INFANT : 9.89E-07 : 1.06E-04 : 2.69E-06 : 2.55E-06 : 2.97E-06 : 6.92E-04 : 1.59E-05 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+_--________+__________
TABLE 1.
DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-MARCH 2004 (CONTINUED)
SPECIAL LOCATION NO.
2 A Site Boundary AT
.67 MILES N
ANNUAL BETA AIR DOSE -
3.24E-04 MILLRADS ANNUAL GAMMA AIR DOSE -
3.09E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+__________+__________+_________+__________+__________+__________+__--________+-________+
PLUME
- 2.07E-04 : 2.07E-04 : 2.07E-04 : 2.07E-04 : 2.07E-04 : 2.07E-04 : 2.10E-04 : 5.37E-04
-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+
GROUND
- 3.71E-06 : 3.71E-06
- 3.71E-06 : 3.71E-06 : 3.71E-06 : 3.71E-06 : 3.71E-06
- 4.35E-06
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I
ADULT 1.67E-05 s 2.78E-05 s 1.52E-04 s 2.25E-05 s 3.83E-05 7.25E-03 s 2.93E-08 s 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--________+____-____+
TEEN
- 2.45E-05 : 3.36E-05 s 2.49E-04 s 3.40E-05 : 5.80E-05 s 9.77E-03 s 5.48E-08 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+
CHILD s 4.78E-05 s 2.65E-05 s 6.03E-04 s 5.75E-05 s 9.34E-05 : 1.87E-02 : 8.34E-08 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT 3.93E-07 3.89E-07 1.78E-06 6.16E-07 1.03E-06 1.95E-04 2.38E-09 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-__+-___+
TEEN s 2.98E-07 s 2.41E-07 s 1.48E-06 s 5.01E-07 s 8.39E-07 s 1.41E-04 s 2.25E-09 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-4___-+____-
CHILD s 4.30E-07 s 1.47E-07 s 2.78E-06 s 6.67E-07 s 1.07E-06 : 2.13E-04 : 2.65E-09 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
ADULT s 9.84E-06 5.75E-06 1.82E-05 1.70E-05 2.90E-05 s 5.45E-03 s 2.01E-08 s 0.OOE+00
___-_-_____+_
+__________+__________+__________+__-__- ____
+__________+__________+_________+-
TEEN
- 1.63E-05 : 7.76E-06 s 3.32E-05 : 3.03E-05 s 5.17E-05 s 8.62E-03 : 4.15E-08 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+--_________+_________+
CHILD
- 3.03E-05 : 6.21E-06 : 8.08E-05 s 5.28E-05 s 8.60E-05 s 1.71E-02 s 6.38E-08 s 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--_________+_________+
INFANT s 5.73E-05 s 6.16E-06 s 1.63E-04 s 1.29E-04 s 1.50E-04 s 4.15E-02 s 1.15E-07 s 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK s s
ADULT
- 1.22E-05 7.76E-06 2.78E-05 2.08B-05 3.49E-05 6.53E-03 6.02E-08 0.00E+00
_________+__________+__________+__________+__________+__________+__________+--4_________+_+_+_____
TEEN
- 2.01E-05 : 1.05E-05 : 5.06E-05 : 3.69E-05 : 6.22E-05 : 1.03E-02 : 1.24E-07 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+--_________+__________
CHILD
- 3.72E-05 : 8.41E-06 : 1.24E-04 : 6.43E-05 s 1.03E-04 s 2.05E-02 s l.91E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--4_________++________
INFANT : 7.02E-05 : 8.35E-06 : 2.45E-04 : 1.57E-04 s 1.80E-04 s 4.98E-02 : 3.46E-07 s 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL s
s s
s s
ADULT 9.54E-07 3.21E-06 1.85E-06 2.02E-06 3.47E-06 5.17E-04 1.03E-05 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--4_________+_______++
TEEN
- 1.25E-06 : 1.49E-05 : 2.61E-06 : 2.78E-06 : 4.79E-06 : 6.50E-04 : 1.77E-05 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--+-4.-_____+_________
CHILD s 1.37E-06 s 1.21E-04 s 3.56E-06 s 2.74E-06 s 4.50E-06 s 7.55E-04 s 1.58E-05 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--_________+__________
INFANT : 9.89E-07 s 1.07E-04 s 2.69E-06 : 2.55E-06 s 2.97E-06 s 6.92E-04 s 1.59E-05 s 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--4_________+_________
TABLE 1.
DOSES TO MAXIMUM INDIVIDUAL (MREM),
JANUARY-MARCH 2004 (CONTINUED)
SPECIAL LOCATION NO.
3 A Nearest Resident AT
.90 MILES NW ANNUAL BETA AIR DOSE a 2.28E-04 MILLRADS ANNUAL GAMMA AIR DOSE a 3.02E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+______-___+________-_+________-_+_________-+-_________+__________+-_________+_________-+
PLUME
- 2.03E-04 : 2.03E-04 : 2.03E-04 : 2.03E-04 : 2.03E-04 : 2.03E-04 : 2.05E-04 z 4.39E-04
-________+__________+__________+__________+__________+__________+__________+_---________+_________
GROUND
- 1.37E-06 : 1.37E-06 : 1.37E-06 : 1.37E-06 : 1.37E-06 : 1.37E-06 : 1.37E-06 : 1.61E-06
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET s
ADULT 5.61E-06 : 9.40E-06 : 5.15E-05 : 7.52E-06 : 1.27E-05 2.41E-03 : 1.43E-08 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_---________-+____-__+
TEEN
- 8.20E-06 : 1.13E-05 : 8.42E-05 : 1.14E-05 : 1.93E-05 : 3.24E-03 : 2.68E-08 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________----_________--+___-__+
CHILD
- 1.60E-05 : 8.93E-06 : 2.04E-04 : 1.92E-05 : 3.10E-05 : 6.21E-03 : 4.08E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT I
ADULT 1.33E-07 1.34E-07 6.06E-07 : 2.08E-07 : 3.42E-07 6.47E-05 1.16E-09.0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_---____4___+_________
TEEN
- 1.OOE-07 : 8.29E-08 : 5.04E-07 : 1.69E-07 : 2.79E-07 : 4.69E-05 : 1.10E-09 : 0.OOE+00 s
-________+__________+__________+__________+__________+__________+__________+_--________+____-_____
CHILD
- 1.44E-07 : 5.04E-08 : 9.42E-07 : 2.25E-07 : 3.55E-07 : 7.08E-05 : 1.30E-09 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
ADULT
- 3.29E-06 1.92E-06 6.12E-06 5.69E-06 : 9.64E-06 s 1.81E-03 s 9.83E-09 0.OOE+00
_________+_____-_____+__________+__________+__________+__________+__________+--
TEEN
- 5.45E-06 : 2.59E-06 : 1.11E-05 : 1.01E-05 s 1.72E-05 : 2.86E-03 : 2.03E-08 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+-_______+________+
CHILD
- 1.01E-05 : 2.07E-06 : 2.71E-05 : 1.76E-05 : 2.86E-05 : 5.66E-03 : 3.12E-08 : 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_---________--+-+-___+
INFANT : 1.90E-05 : 2.06E-06 s 5.43E-05 : 4.29E-05 : 4.97E-05 : 1.38E-02 : 5.65E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
I ADULT
- 4.10E-06 : 2.59E-06 9.38E-06 : 6.98E-06 : 1.16E-05 : 2.17E-03 2.95E-08 : 0.OOE+00
-_________+_____
____+__________
__________+___
______+________
_+__________+_-
________+_________
TEEN
- 6.73E-06 : 3.50E-06 : 1.71E-05 : 1.24E-05 : 2.07E-05 : 3.43E-03 : 6.09E-08 : 0.OOE+00 :
-_________+__________+__________+_________+__________+__________+__________+_--________+__________
CHILD
- 1.24E-05 : 2.80E-06 : 4.16E-05 : 2.16E-05 : 3.44E-05 : 6.80E-03 : 9.36E-08 : 0.OOE+00
_________+__________+__________+__________+_____-___-__+_______+__________+__________+____-__-___
INFANT : 2.34E-05 : 2.79E-06 : 8.21E-05 : 5.25E-05 : 5.99E-05 s 1.65E-02 : 1.69E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT s 3.40E-07 s 1.21E-06 : 6.61E-07 7.18E-07 : 1.22E-06 : 1.81E-04 3.75E-06 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--4.-______+________+
TEEN
- 4.47E-07 : 5.49E-06 : 9.33E-07 : 9.89E-07 : 1.69E-06 : 2.27E-04 : 6.45E-06 : 0.OOE+00 :
-________+__________+__________+__________+__________+__________+__________+_--+-_______+_________
CHILD
- 4.91E-07 : 4.41E-05 : 1.27E-06 : 9.74E-07 : 1.58E-06 : 2.64E-04 : 5.76E-06 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--________+_________+
INFANT : 3.54E-07 : 3.88E-05 : 9.58E-07 : 9.07E-07 : 1.05E-06 : 2.42E-04 : 5.81E-06 : 0.OOE+00 :
-_________+__________+__________+_________+__________+__________+__________+_--+________+-________
TABLE 1.
DOSES TO MAXIMUM INDIVIDUAL (MREM),
JANUARY-MARCH 2004 (CONTINUED)
SPECIAL LOCATION NO.
4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE. 1.61E-04 MILLRADS ANNUAL GAMMA AIR DOSE. 2.62E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_________+______-___+_______-_+________-_+________-_+________-_+________-_+________-_+_________-_
PLUME
- 1.76E-04 : 1.76E-04 : 1.76E-04
- 1.76E-04 : 1.76E-04 : 1.76E-04 : 1.77E-04
- 3.45E-04
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GROUND
- 1.11E-07 : 1.11E-07
- 1.11E-07
- 1.11E-07
- 1.11E-07 : 1.11E-07 : 1.11E-07
- 1.29E-07 VEGET ADULT 3.29E-07 5.69E-07 3.17E-06 4.35E-07 7.23E-07 1.36E-04 1.87E-09 0.OOE+00
-________+-_________+______-___+________-_+________-_+________-_+________-_+________-_+_________-_
TEEN
- 4.77E-07 : 6.86E-07 : 5.12E-06 : 6.57E-07 : 1.10E-06 : 1.83E-04 : 3.50E-09 : 0.OOE+00
_______-_+__________+____-__-__-+_________+_________-+_________-+__________+________--+________-_
CHILD
- 9.24E-07 : 5.40E-07 : 1.23E-05 : 1.11E-06 : 1.76E-06 : 3.52E-04 : 5.33E-09 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT
- 8.11E-09 8.67E-09 3.80E-08 1.25E-08 1.96E-08 : 3.66E-06 : 1.52E-10 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+_---__+_+_____-+___-__
TEEN
- 5.94E-09 : 5.37E-09 : 3.13E-08 : 1.02E-08 : 1.60E-08 : 2.65E-06 : 1.44E-10 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+_--________+____-_____
CHILD
- 8.36E-09 : 3.27E-09 : 5.80E-08 : 1.35E-08 : 2.03E-08 s 4.OOE-06 : 1.69E-10 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK:
ADULT
- 1.91E-07 1.11E-07 3.62E-07 : 3.29E-07 : 5.48E-07 1.02E-04 1.28E-09 0.OOE+00
-___-______+___
_____+________+__________-+__________+__________-4__-_____
+__________+______-__-+
TEEN
- 3.13E-07
- 1.49E-07 : 6.55E-07 : 5.84E-07 : 9.78E-07 : 1.62E-04 : 2.65E-09
- 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--+________+-________
CHILD
- 5.74E-07 : 1.20E-07 : 1.59E-06 : 1.02E-06 : 1.63E-06 : 3.21E-04 : 4.07E-09 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--+-________-+--+___-
INFANT : 1.08E-06 s 1.19E-07 : 3.16E-06 : 2.47E-06 : 2.83E-06 : 7.80E-04 : 7.37E-09 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 2.45E-07 : 1.49E-07 : 5.67E-07 4.15E-07 6.65E-07 : 1.23E-04 3.84E-09 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--________+_________+
TEEN
- 3.94E-07 : 2.01E-07 : 1.03E-06 : 7.37E-07 : 1.19E-06 : 1.94E-04 : 7.94E-09 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_---+-_____+__________
CHILD
- 7.13E-07 : 1.61E-07 : 2.49E-06 : 1.28E-06 s 1.97E-06 : 3.85E-04 : 1.22E-08 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+___+____+-________
INFANT : 1.33E-06 : 1.60E-07 : 4.84E-06 : 3.09E-06 : 3.43E-06 : 9.35E-04 : 2.21E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL I
ADULT
- 4.31E-08 : 2.02E-07 : 8.07E-08 9.02E-08 : 1.40E-07 1.88E-05 4.64E-07 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_---_____+___-+___-___
TEEN
- 5.70E-08 : 7.24E-07 : 1.13E-07 : 1.24E-07 : 1.93E-07 : 2.36E-05 : 7.94E-07 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_---+-+-4.-+-__-+___-_
CHILD
- 6.42E-08 : 5.24E-06 : 1.52E-07 : 1.22E-07 : 1.81E-07 : 2.76E-05 : 7.07E-07 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--________+__________+
INFANT
- 4.61E-08 : 4.60E-06 : 1.14E-07 : 1.14E-07 : 1.20E-07 : 2.53E-05
- 7.11E-07 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--+-+-4.-_____-+____-
TABLE 1. DOSES TO MAXIMUM INDIVIDUAL (MREM),
JANUARY-MARCH 2004 (CONTINUED)
SPECIAL LOCATION NO.
5 A Nearest Garden AT 1.20 MILES SE ANNUAL BETA AIR DOSE. 1.08E-04 MILLRADS ANNUAL GAMMA AIR DOSE -
1.77E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_________+__________+__________+__________+__________+__________+__________+--_________+-________+
PLUME
- 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.20E-04 : 2.33E-04
_________+__________+__________+__________+__________+__________+__________+---_________--+______+
GROUND
- 1.01E-06 : 1.01E-06 : 1.01E-06 : 1.01E-06 : 1.01E-06 : 1.01E-06 : 1.01E-06 : 1.20E-06
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I
I ADULT
- 4.48E-06 7.65E-06 : 4.23E-05 : 5.94E-06 9.97E-06 1.89E-03 1.74E-08 *0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--_________+-________+
TEEN
- 6.52E-06 : 9.23E-06 : 6.88E-05 : 8.98E-06 : 1.51E-05 : 2.54E-03 : 3.27E-08 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+---_________-+-+__-__+
CHILD
- 1.27E-05 : 7.27E-06 : 1.66E-04 : 1.52E-05 : 2.44E-05 : 4.87E-03 : 4.97E-08 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT 1.08E-07 1.12E-07 5.01E-07 1.67E-07 2.70E-07 5.07E-05 1.42E-09 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--+__+______+-_______+
TEEN
- 8.02E-08 : 6.94E-08 : 4.15E-07 : 1.36E-07 : 2.20E-07 : 3.67E-05 : 1.34E-09 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--+-+-____+___-+__-__+
CHILD
- 1.14E-07 : 4.22E-08 : 7.73E-07 : 1.81E-07 : 2.80E-07 s 5.55E-05 s 1.58E-09 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK:
s s
ADULT
- 2.60E-06 : 1.51E-06 : 4.90E-06 : 4.48E-06 7.55E-06 1.42E-03 1.20E-08 O.OOE+00
+-+--------------------------------------+----------
+__-_______
+________-_+
TEEN s 4.29E-06 s 2.03E-06 s 8.89E-06 s 7.96E-06 : 1.35E-05 2.24E-03 : 2.47E-08 0.00E+00
_________+__________+__________+__________+__________+__________+__________+--_________+_________+
CHILD
- 7.91E-06 : 1.63E-06 : 2.16E-05 : 1.39E-05 : 2.24E-05 : 4.43E-03 : 3.80E-08 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--________+++______+__
INFANT : 1.49E-05 : 1.61E-06 : 4.32E-05 : 3.38E-05 : 3.89E-05 : 1.08E-02 : 6.87E-08 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 3.29E-06 2.03E-06 7.60E-06 5.57E-06 9.12E-06 1.70E-03 3.59E-08 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--_________+__________
TEEN
- 5.34E-06 : 2.75E-06 : 1.38E-05 : 9.89E-06 : 1.63E-05 : 2.69E-03 : 7.41E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--4_________+_________
CHILD
- 9.77E-06 : 2.20E-06
- 3.36E-05 : 1.72E-05 : 2.70E-05 : 5.32E-03 : 1.14E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--_________+__________
INFANT : 1.84E-05 : 2.19E-06 s 6.58E-05 : 4.17E-05 : 4.70E-05 : 1.29E-02 : 2.06E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT 1.25E-07 2.49E-07 2.42E-07 2.60E-07 4.38E-07 6.55E-05 5.01E-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--4_________+_________
TEEN
- 1.65E-07 : 5.10E-07 : 3.41E-07 : 3.58E-07 : 6.04E-07 : 8.22E-05 : 8.61E-07 : 0.OOE+00 :
-_________+__________+__________+_________+__________+__________+__________+_--4________+_________
CHILD
- 1.81E-07 : 2.53E-06 : 4.65E-07 : 3.52E-07 : 5.67E-07 : 9.51E-05 : 7.67E-07 : 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_--________+__________
INFANT : 1.30E-07 : 2.18E-06 : 3.49E-07 : 3.28E-07 : 3.74E-07 : 8.71E-05 : 7.43E-07 : 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_--________+__________
TABLE 2. DOSES TO MAXIMUM INDIVIDUAL (MREM), APRIL-JUNE 2004 SPECIAL LOCATION NO.
1 A
Site Boundary AT
.67 MILES N
ANNUAL BETA AIR DOSE -
4.97E-05 MILLRADS ANNUAL GAMMA AIR DOSE = 8.76E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_________+__________+__________+__________+__________+__________+__________+--_________+-________+
PLUME
- 5.86E-05 : 5.86E-05 : 5.86E-05
- 5.86E-05 : 5.86E-05 : 5.86E-05 : 5.91E-05 : 1.12E-04 GROUND
- 1.03E-05 : 1.03E-05 : 1.03E-05
- 1.03E-05 : 1.03E-05 : 1.03E-05 : 1.03E-05 : 1.21E-05
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I
ADULT s 2.15E-05 : 1.79E-05 : 5.60E-05
- 3.61E-05
- 6.18E-05 1.17E-02 1.38E-09 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--+_________+-_______+
TEEN
- 3.06E-05 : 2.06E-05 : 8.74E-05
- 5.44E-05
- 9.36E-05 : 1.58E-02 : 2.51E-09 : O.00E+00 CHILD
- 5.55B-05 : 1.58E-05 : 2.05E-04
- 9.19E-05 : 1.51E-04 : 3.03E-02 : 3.76E-09 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT 5.77E-07 5.55E-07 1.05E-06 9.68E-07 1.65E-06 3.15E-04 5.23E-11 0.0OE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN
- 4.41E-07 : 3.32E-07 : 8.57E-07
- 7.87E-07 : 1.35E-06 : 2.28E-04 : 4.95E-11 : O.OOE+00 CHILD
- 6.27E-07 : 1.94E-07 : 1.58E-06
- 1.05E-06 : 1.71E-06
- 3.45E-04 : 5.79E-l1 : O.OOE+00 COW MILK :
I I
ADULT
- 1.55E-05 8.12E-06 2.05E-05 2.74E-05 : 4.70E-05 : 8.82E-03 : 4.89E-11 : 0.OOE+00 TEEN
- 2.59E-05 : 1.09E-05 s 3.70E-05 : 4.87E-05 : 8.38E-05 s 1.40E-02 : 1.01E-10 : O.OOE+00 CHILD
- 4.79E-05 : 8.78E-06 : 8.97E-05 : 8.49E-05 : 1.39E-04
- 2.77E-02
- 1.55E-10 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+--_________+________++
INFANT : 9.06E-05 : 8.68E-06 : 1.85E-04 : 2.08E-04 : 2.42E-04 : 6.72E-02 : 3.74E-10 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 1.86E-05 9.71E-06 2.57E-05 3.29E-05 5.64E-05 1.06E-02 5.86E-12 O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN
- 3.11E-05 : 1.31E-05 : 4.64E-05 : 5.84E-05 : 1.01E-04
- 1.68E-02 : 1.21E-il : 0.00E+00 CHILD
- 5.75E-05 : 1.05E-05 : 1.12E-04
- 1.02E-04
- 1.67E-04 : 3.32E-02
- 1.86E-li : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INFANT : 1.09E-04 : 1.04E-05 s 2.30E-04
- 2.49E-04 : 2.91E-04 s 8.06E-02 : 4.49E-11 : O.OOE+00 INHAL ADULT
- 1.08E-06 : 3.20E-06 1.54B-06 2.36B-06 4.04K-06 5.83B-04 9.33E-06 O.00E+OO TEEN
- 1.42E-06 : 1.67E-05 : 2.17E-06
- 3.25E-06
- 5.57E-06 : 7.35E-04 : 1.60E-05 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
CHILD
- 1.56E-06 : 1.40E-04 : 2.95E-06 : 3.20E-06 : 5.23E-06 : 8.58E-04 : 1.43E-05 : O.OOE+00 INFANT : 1.12E-06 : 1.23E-04 : 2.34E-06 : 2.98E-06 : 3.45E-06 s 7.86E-04 : 1.46E-05 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+--_________+__________
TABLE 2.
DOSES TO MAXIMUM INDIVIDUAL (MREM), APRIL-JUNE 2004 (CONTINUED)
SPECIAL LOCATION NO.
2 A Site Boundary AT
.60 MILES NNE ANNUAL BETA AIR DOSE = 3.79E-05 MILLRADS ANNUAL GAMMA AIR DOSE a 6.68E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_________+__________+__________+__________+__________+__________+__________+__________+__________+
PLUME
- 4.47E-05 : 4.47E-05 : 4.47E-05 : 4.47E-05 : 4.47E-05 : 4.47E-05 : 4.51E-05 : 8.53K-05 GROUND
- 6.33E-06 : 6.33E-06 : 6.33E-06 : 6.33E-06 : 6.33E-06 : 6.33E-06 : 6.33E-06 : 7.41E-06 VEGET I
ADULT 1.32E-05 1.09E-05 3.42E-05 2.22E-05 3.81E-05 7.22E-03 8.37E-10 0.OOE+00 TEEN
- 1.88E-05 : 1.26E-OS : 5.34E-05 : 3.35E-05 : 5.76E-05 : 9.73E-03 : 1.52E-09 : O.OOE+00 CHILD
- 3.41E-05 : 9.67E-06 : 1.25E-04 : 5.66E-05 : 9.28E-05 : 1.86E-02 : 2.28E-09 : O.OOE+00 MEAT ADULT
- 3.55E-07 : 3.40E-07 : 6.40E-07 5.96E-07 1.02E-06 1.94E-04 3.17E-11 0.00E+00 TEEN
- 2.72E-07 : 2.03E-07 : 5.25E-07 : 4.85E-07 : 8.29E-07 : 1.41E-04 : 3.00E-11 0.00E+00 CHILD
- 3.86E-07 : 1.19E-07 : 9.65E-07 : 6.45E-07 : 1.05E-06 : 2.12E-04 : 3.51E-11 : 0.00E+00 COW MILK:
ADULT
- 9.55E-06 4.99E-06 1.26E-05 1.69E-05 2.89E-05 5.43E-03 : 2.96E-11 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN
- 1.59E-05 : 6.73E-06 : 2.28E-05 : 3.00E-05 : 5.16E-05 : 8.60E-03 : 6.13E-11 : 0.00E+00 CHILD
- 2.95E-05 : 5.40E-06 : 5.52E-05 : 5.22E-05 : 8.58E-05 : 1.70E-02 : 9.37E-11 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INFANT : 5.58E-05 : 5.34E-06 : 1.14E-04 : 1.28E-04 : 1.49E-04 : 4.14E-02 : 2.27E-10 : 0.00E+00 GOATHILK:
ADULT
- 1.15E-05 : 5.97E-06 : 1.58E-05 a 2.02E-05 : 3.47E-05 6.52E-03 a 3.55E-12 a 0.00E+00 TEEN
- 1.91E-05 : 8.06E-06 : 2.85E-05 : 3.60E-05 : 6.19E-05 : 1.03E-02 : 7.35E-12 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
CHILD
- 3.54E-05 : 6.47E-06 : 6.90E-05 : 6.27E-05 : 1.03E-04 : 2.04E-02 : 1.12E-11 : 0.00E+00 INFANT : 6.70E-05 : 6.40E-06 : 1.42E-04 : 1.53E-04 : 1.79E-04 : 4.97E-02 : 2.72E-11 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL a
a a
a ADULT a 8.50E-07 a 2.53E-06 a 1.22E-06 a 1.86E-06 : 3.18E-06 a 4.60E-04 a 7.39E-06 a 0.00E+00
-________+__________+__________+__________+__________+__________+__________+_--+-____+___+_+-___+
TEEN
- 1.12E-06 : 1.33E-05 : 1.71E-06 : 2.56E-06 : 4.39E-06 : 5.80E-04 : 1.27E-05 : 0.00E+00 CHILD
- 1.23E-06 : 1.11E-04 : 2.33E-06 : 2.52E-06 : 4.12E-06 : 6.76E-04 : 1.13E-05 a 0.00E+00
-________+__________+__________+__________+__________+__________+__________+_--+-+-__+_+_+_+-___+
INFANT : 8.86E-07 : 9.75E-05 : 1.84E-06 : 2.35E-06 : 2.72E-06 : 6.20E-04 : 1.16E-05 : 0.00E+00
-________+__________+__________+__________+__________+__________+__________+_--+-__+______-+__-__+
TABLE 2.
DOSES TO MAXIMUM INDIVIDUAL (MREM),
APRIL-JUNE 2004 (CONTINUED)
SPECIAL LOCATION NO.
3 A Nearest Resident AT
.90 MILES NW ANNUAL BETA AIR DOSE -
2.84E-05 MILLRADS ANNUAL GAMMA AIR DOSE -
5.01E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-+__________+__________+__________+__________+__________+__________+-
______+____- __
+
PLUME s 3.35E-05 : 3.35E-05 : 3.35E-05 : 3.35E-05 : 3.35E-05 : 3.35E-05 : 3.38E-05
- 6.40E-05
________-+__________+__________+__________+_________+__________+__________+_--________+____-____+
GROUND
- 1.33E-06 : 1.33E-06 : 1.33E-06 : 1.33E-06 : 1.33E-06 : 1.33E-06 : 1.33E-06 : 1.56E-06
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT 3.21E-06 2.67E-06 8.39E-06 : 5.39E-06 9.23E-06 1.75E-03 2.07E-10 : 0.00E+00
-________+
__________+__________+__________+__________+__________+__________+___-
+___
+
TEEN
- 4.57E-06 3.08E-06 : 1.31E-05 : 8.12E-06 : 1.40E-05 : 2.36E-03 : 3.76E-10
- O.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--________+____-____+
CHILD
- 8.29E-06 : 2.37E-06 : 3.07E-05 : 1.37E-05
- 2.25E-05 : 4.52E-03 : 5.64E-10 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT s 8.63E-08 8.33B-08 1.56E-07 1.45E-07 2.46E-07 4.71E-05 : 7.84E-12 0.00E+00
________-+__________+__________+__________+_________+__________+__________+_---+-+-+-____-+__-__+
TEEN
- 6.60E-08 : 4.98E-08 : 1.28E-07 : 1.18E-07 : 2.01E-07 : 3.41E-05 : 7.42E-12 : 0.OOE+00
-+__________+__________+__________+
_________+__________+__________+_--+
-__+___+___+-_
_+
CHILD
- 9.37E-08 : 2.91E-08 : 2.36E-07 : 1.57E-07 : 2.56E-07 : 5.15E-05 : 8.68E-12 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILXK:
s ADULT
- 2.31E-06 1.20E-06 3.05E-06 4.08E-06 : 7.00E-06 1.32E-03 7.33E-12 0.00E+00
_________+_
-_________+__________+__________+_ ________+__________+__________+__-
+----+-
+
TEEN
- 3.86E-06 : 1.62E-06 : 5.52E-06
- 7.25E-06 : 1.25E-05 2.08E-03 1.52E-11 : 0.00E+00
________-+__________+__________+__________+_________+__________+__________+_--________+__________+
CHILD
- 7.14E-06 s 1.30E-06 : 1.34E-05
- 1.26E-05
- 2.08E-05 : 4.13E-03 : 2.32E-11 : 0.00E+00
________-+__________+__________+__________+_________+__________+__________+_--+________+-_______+
INFANT : 1.35E-05 : 1.28E-06 : 2.76E-05
- 3.09E-05
- 3.61E-05 : 1.00E-02
- 5.61E-11 : 0.00E+00 GOATMILK :
I ADULT
- 2.78E-06 : 1.44E-06 3.83E-06 4.90E-06 : 8.40E-06 1.58E-03 8.80B-13 0.00E+00
_________+_-_________+__________+__________+_________+__________+__________+_--+________+-________
TEEN
- 4.64E-06 : 1.94E-06 : 6.92E-06 : 8.70E-06 : 1.50E-05
- 2.50E-03
- 1.82E-12
- 0.00E+00
_________+_-_________+__________+__________+_________+__________+__________+_--+-4.-4.-+_________+
CHILD
- 8.58E-06 : 1.56E-06 : 1.68E-05 : 1.52E-05 : 2.49E-05 : 4.95E-03
- 2.78E-12
- 0.00E+00
________-+__________+__________+__________+_________+__________+__________+_--________+__________+
INFANT : 1.62E-05 : 1.54E-06 : 3.43E-05 : 3.71E-05 : 4.34E-05 : 1.20E-02
- 6.73E-12 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT
- 1.92E-07 : 3.55E-07 2.72E-07 4.12E-07 6.89E-07 9.96E-05 : 5.37E-07 0.005E+00
_________+__________+__________+__________+__________+__________+__________-+_-__-____-+_-____-__-
TEEN
- 2.52E-07 : 1.04E-06 : 3.82E-07 : 5.67E-07 : 9.50E-07 : 1.25E-04
- 9.10E-07 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________-+_-__-____-+_-____-__-
CHILD
- 2.78E-07 : 6.74E-06 : 5.19E-07 : 5.58E-07 : 8.92E-07
- 1.46E-04
- 8.06E-07 : 0.00E+00
_________+_--4________+__________+__________+__________+______--__-+__________+_______+_________+-
INFANT : 2.00E-07 : 5.89E-06 : 4.09E-07 : 5.20E-07 : 5.89E-07
- 1.34E-04 : 8.09E-07 : 0.00E+00
_________+__________+__________+_________--+---________+________+__________+__________+___-_--____
TABLE 2. DOSES TO MAXIMUM INDIVIDUAL (MREM), APRIL-JUNE 2004 (CONTINUED)
SPECIAL LOCATION NO.
4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE -
2.84E-05 MILLRADS ANNUAL GAMMA AIR DOSE -
5.01E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_________+__________+__________+__________+__________+__________+__________+__________+__________+
PLUME
- 3.35E-05 : 3.35E-05 : 3.35E-05 : 3.35E-05 : 3.35E-05
- 3.35E-05
- 3.38K-05 : 6.40E-05 GROUND
- 1.69E-07 : 1.69E-07 : 1.69B-07 : 1.69B-07 : 1.69B-07 : 1.69E-07 : 1.69K-07 : 1.98E-07
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT
- 2.98E-07 : 4.22E-07 : 1.50B-06 : 4.64B-07 : 7.95B-07 : 1.51K-04 : 5.26K-11 : O.OOE+00 TEEN
- 4.28E-07 : 4.95E-07 : 2.35E-06 : 6.99E-07 : 1.20E-06 : 2.03B-04
- 9.56K-l1 : O.OOE+00 CHILD
- 7.95K-07 : 3.84E-07 : 5.52K-06 : 1.18K-06 : 1.94K-06 : 3.89K-04
- 1.43B-10 : O.OOK+00 MEAT ADULT
- 7.71K-09 : 1.16E-08 : 2.28K-08 : 1.24K-08 : 2.12K-08 : 4.05K-06 : 1.99K-12 : O.OOK+00 TEEN
- 5.90B-09 : 7.06B-09 : 1.85K-08 : 1.01E-08 : 1.73K-08
- 2.93K-06
- 1.89E-12 : 0.O+00:
CHILD
- 8.47B-09
- 4.20B-09 : 3.38K-08 : 1.35K-08 : 2.20K-08
- 4.42K-06
- 2.21E-12 : O.OOE+00 COW MILK:
X ADULT 2.OOK-07
- 1.13B-07 : 2.99K-07 : 3.53B-07 : 6.05E-07 : 1.13B-04
- 1.86B-12 O.OOE+00 TEEN
- 3.34K-07
- 1.52B-07 : 5.39K-07 : 6.27Z-07 : 1.08K-06 : 1.80B-04 : 3.85B-12
- O.OOB+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
CHILD
- 6.20E-07
- 1.23E-07 : 1.30E-06 : 1.09E-06 : 1.79E-06 : 3.56E-04
- 5.89B-12 : O.O+00:
INFANT : 1.17E-06 : 1.21E-07 : 2.64K-06 : 2.67K-06 : 3.12K-06 : 8.64B-04 : 1.43K-11 : O.O+00:
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 2.41E-07
- 1.35B-07 : 4.02K-07 : 4.23B-07 : 7.26E-07 : 1.36B-04 : 2.24B-13 O.OOE+00
-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+
TEEN
- 4.03B-07
- 1.83B-07 : 7.21K-07
- 7.52E-07 : 1.30K-06 : 2.15B-04 : 4.62E-13
- 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
CHILD
- 7.48E-07 : 1.47B-07 : 1.74K-06
- 1.31K-06 : 2.15K-06 : 4.27B-04 : 7.07K-13
- O.OOK+00 INFANT : 1.41K-OS : 1.46E-07 : 3.47K-06 : 3.21K-06 : 3.75K-06 : 1.04K-03 : 1.71B-12
- O.OOK+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL s
ADULT
- 3.66E-08 : 1.77E-07 : 5.26K-08 : 7.66K-08 : 1.10B-07 : 1.39K-05 : 2.70B-07 : O.O+00:
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN
- 4.88E-08 : 4.79E-07
- 7.35E-08 : 1.06E-07 : 1.52E-07 : 1.76E-05 : 4.56B-07 : 0.OOE+00 CHILD
- 5.59K-08 : 2.88E-06 : 9.94E-08 : 1.04E-07 : 1.43E-07 : 2.06K-05 : 4.04K-07 : O.OOE+00 INFANT : 4.02K-OS : 2.51E-06
- 7.67E-08 : 9.68E-08 : 9.45E-08 : 1.89E-05 : 4.03B-07 : 0.OOE+00
-________+______-___+__________+_________-+________-_+________-_+________-_+________-_+________-_+
TABLE 2.
DOSES TO MAXIMUM INDIVIDUAL (MREM),
APRIL-JUNE 2004 (CONTINUED)
SPECIAL LOCATION NO.
5 A Nearest Garden AT 1.20 MILES SE ANNUAL BETA AIR DOSE a 5.33E-07 MILLRADS ANNUAL GAMMA AIR DOSE -
3.72E-07 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+-_________+______-___+________-_+________-_+________-_+________-_+_________-+_________-+
PLUME
- 2.48E-07 : 2.48E-07 : 2.48E-07 : 2.48E-07 : 2.48E-07 : 2.48E-07 : 2.54E-07 : 7.64E-07
_________+-_________+_______-__+________-_+_________-+-_________+__________+_________-+________-_+
GROUND
- 6.01E-07 : 6.01E-07 : 6.01E-07 : 6.01E-07 : 6.01E-07 : 6.01E-07 : 6.01E-07 : 7.07E-07
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT 1.52E-06 1.25E-06 3.90E-06 2.55E-06 4.38E-06 : 8.30E-04 : 9.44E-11 : 0.OOE+00
_________+______-___+_________-+_________-+________-_+________-_+_______-__+________-_+________-_+
TEEN
- 2.16E-06 : 1.44E-06 : 6.08E-06
- 3.85E-06 : 6.62E-06 s 1.12E-03 t 1.71E-10 : 0.OOE+00
_________+______-___+_________-+_________-+________-_+________-_+________-_+________-_+________-_+
CHILD
- 3.92E-06 : 1.10E-06 : 1.43E-05 : 6.50E-06 : 1.07E-05 : 2.14E-03 : 2.57E-10
- 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT a
a a
a ADULT : 4.08E-08 : 3.89E-08 a 7.32E-08 a 6.85E-08 a 1.17E-07 a 2.23E-05 a 3.57E-12 a 0.OOE+00
_________+-_________+_______-__+_________-+________-_+________-_+________-_+________-_+________-_+
TEEN
- 3.12E-08 : 2.32E-08 : 6.OOE-08
- 5.57E-08 : 9.53E-08 : 1.62E-05 : 3.38E-12
- 0.OOE+00 a
_________+______-___+_________-+________-_+________-_+________-_+________-_+_______-__+________-_+
CHILD
- 4.43E-08 : 1.36E-08 : 1.10E-07
- 7.42E-08
- 1.21E-07 : 2.44E-05 : 3.96E-12
- 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
ADULT : 1.10E-06 a 5.73E-07 a 1.44E-06 a 1.94E-06 a 3.32E-06 a 6.24E-04 a 3.34E-12 a 0.OOE+00 a
_________+______-___+_________-+_______-__+________-_+________-_+________-_+_______-__+________-_+
TEEN
- 1.83E-06 : 7.73E-07 : 2.61E-06 : 3.44E-06 : 5.93E-06 : 9.88E-04 : 6.91E-12 : 0.OOE+00 a
_________+______-___+________-_+________-_+________-_+_______-__+________-_+________-_+________-_+
CHILD
- 3.39E-06 : 6.19E-07 : 6.33E-06 : 6.OOE-06 a 9.86E-06 : 1.96E-03 : 1.06E-11 : 0.OOE+00 a
_________+______-___+________-_+________-_+_______-__+_______-__+________-_+________-_+________-_+
INFANT : 6.41E-06 a 6.13E-07 : 1.31E-05 : 1.47E-05 : 1.72E-05 : 4.76E-03 : 2.56E-11 a 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
a a
a ADULT : 1.32E-06 : 6.86E-07 a 1.81E-06 a 2.33E-06 a 3.99E-06 a 7.49E-04 a 4.01E-13 a 0.OOE+00 a
_________+______
___+__
+_____
____+
__+___
___+_---________- +___- __
+
TEEN
- 2.20E-06 : 9.25E-07 : 3.27E-06 : 4.13E-06 : 7.12E-06 : 1.19E-03 : 8.29E-13 : 0.OOE+00
_________+_______-__+_________-+________-_+_________-+________-_+________-_+________-_+________-_+
CHILD
- 4.07E-06 : 7.42E-07 : 7.92E-06 : 7.20E-06 : 1.18E-05 : 2.35E-03 : 1.27E-12 : 0.OOE+00
_________+-_________+_______-__+_______-__+________-_+________-_+________-_+________-_+________-_+
INFANT : 7.70E-06 : 7.34E-07 : 1.63E-05 : 1.76E-05 a 2.06E-05 : 5.71E-03 : 3.07E-12 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL a
a a
a ADULT a 1.51E-07 a 4.48E-07 a 2.18E-07 a 3.31E-07 a 5.72E-07 a 8.30E-05 a 1.30E-06 a 0.OOE+00 a
_________+______
___+__
+_____
____+
__+___
___+_---________- +____- _
+
TEEN
- 1.99E-07 : 2.34E-06 : 3.07E-07 : 4.56E-07 : 7.89E-07 : 1.05E-04 : 2.23E-06 : 0.OOE+00 a
_________+-_________+________-_+_________-+________-_+________-_+________-_+________-_+________-_+
CHILD
- 2.18E-07 : 1.95E-05 : 4.17E-07 : 4.49E-07 : 7.41E-07 : 1.22E-04 : 1.99E-06 : 0.OOE+00
_________+______-___+_________-+_________-+_________-+-_________+__________+_________-+________-_+
INFANT : 1.57E-07 : 1.72E-05 : 3.30E-07 : 4.19E-07 : 4.89E-07 : 1.12E-04 : 2.04E-06 : 0.OOE+00 a
_________+-_________+_______-__+_______-__+_________-+________-_+________-_+________-_+________-_+
TABLE 3. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-JUNE 2004 SPECIAL LOCATION NO.
1 A Site Boundary AT
.69 MILES NNW ANNUAL BETA AIR DOSE = 3.81E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 4.44E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN PLUME 2.97E-04 : 2.97E-04 : 2.97E-04 : 2.97E-04 : 2.97E-04 : 2.97E-04 3.1E-04 :6.90E-04 GROUND
- 8.99E-06 : 8.99E-06 : 8.99E-06 : 8.99E-06 : 8.99E-06 : 8.99E-06 : 8.99E-06 : 1.05E-05
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT
- 2.70E-05 : 3.39E-05 : 1.64E-04 4.05E-05 6.90E-05 1.31E-02 3.66E-08 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--________+____-_____
TEEN
- 3.90E-05 : 4.04E-05 : 2.67E-04 : 6.11E-05 : 1.04E-04 : 1.76E-02 : 6.86E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
CHILD
- 7.36E-05 : 3.16E-05 : 6.43E-04 : 1.03E-04 : 1.68E-04 : 3.38E-02 : 1.04E-07 : O.OOE+00 MEAT ADULT 6.80E-07 6.36E-07 2.14E-06 1.10E-06 : 1.85E-06 : 3.51E-04 2.96E-09 O.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+_+______+-_______+
TEEN
- 5.15E-07 : 3.87E-07 : 1.78E-06 : 8.96E-07 : 1.51E-06 : 2.55E-04 : 2.80E-09 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+__+____++-_______+
CHILD
- 7.36E-07 : 2.31E-07 : 3.32E-06 : 1.19E-06 : 1.92E-06 : 3.84E-04 : 3.29E-09 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
I ADULT
- 1.75E-05 : 9.65E-06 2.77E-05 3.07E-05 5.23E-05 9.82E-03 2.48E-08 O.OOE+00 TEEN s 2.92E-05 : 1.30E-05 : 5.03E-05 : 5.45E-05 9.33E-05 1.56E-02 : 5.12E-08 : O.OOE+00 :
CHILD
- 5.40E-05 : 1.04E-05 : 1.22E-04 : 9.50E-05 : 1.55E-04 : 3.08E-02 : 7.88E-08 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--________+__________
INFANT : 1.02E-04 : 1.03E-05 : 2.48E-04 : 2.32E-04 : 2.70E-04 : 7.48E-02 : 1.43E-07 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMIL I
ADULT
- 2.15E-05 1.23E-05 3.91E-05 3.72E-05 : 6.29E-05 1.18E-02 7.43E-08 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN
- 3.55E-05 : 1.67E-05 : 7.11E-05 : 6.61E-05 : 1.12E-04 : 1.87E-02 : 1.54E-07 : 0.OOE+00 CHILD
- 6.57E-05 : 1.34E-05 : 1.73E-04 : 1.15E-04 : 1.87E-04 : 3.69E-02 : 2.36E-07 : 0.00Z+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INFANT : 1.24E-04 : 1.33E-05 : 3.47E-04 : 2.81E-04 : 3.25E-04 : 8.98E-02 : 4.27E-07 : 0.OOE+00 INHAL I :
ADULT 1.69E-06 : 5.44E-06 2.85E-06 3.64E-06 6.24E-06 : 9.15E-04 1.68E-05 0.00E+00 TEEN
- 2.22E-06 : 2.69E-05 : 4.02E-06 : 5.01E-06 s 8.61E-06 : 1.15E-03 : 2.88E-05 : O.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
CHILD
- 2.44E-06 : 2.22E-04 : 5.48E-06 : 4.93E-06 : 8.09E-06 : 1.34E-03 : 2.57E-05 : O.OOE+00 INFANT : 1.76E-06 : 1.95E-04 : 4.22E-06 : 4.60E-06 : 5.34E-06 : 1.23E-03 : 2.61E-05 : 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_---________+_________
TABLE 3.
DOSES TO MAXIMUM INDIVIDUAL (MREM),
JANUARY-JUNE 2004 (CONTINUED)
SPECIAL LOCATION NO.
2 A Site Boundary AT
.67 MILES N
ANNUAL BETA AIR DOSE = 4.48E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 5.19E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+
PLUME
- 3.48E-04 : 3.48E-04 : 3.48E-04 : 3.48E-04 : 3.48E-04 : 3.48E-04 : 3.53E-04 : 8.09E-04
-________+__________+__________+__________+__________+__________+__________+_--________+____-____+
GROUND
- 1.39E-05 : 1.39E-05 : 1.39E-05 : 1.39E-05 : 1.39E-05 : 1.39E-05 : 1.39E-05 : 1.62E-05
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT 3.94E-05 5.08E-05 2.47E-04 5.87E-05 9.98E-05 1.89E-02 : 6.95E-08 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+
TEEN
- 5.69E-05 : 6.06E-05 : 3.99E-04 : 8.86E-05 : 1.51E-04 : 2.55E-02 : 1.30E-07 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--________+____-____+
CHILD
- 1.07E-04 : 4.74E-05 : 9.60E-04 : 1.50E-04 : 2.44E-04 : 4.88E-02 : 1.98E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT
- 9.94E-07 s 9.65E-07
- 3.22E-06 s 1.61E-06 2.68E-06 5.08E-04 5.61E-09 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_---________-+___-___+
TEEN
- 7.51E-07 : 5.88E-07 : 2.67E-06 : 1.31E-06 : 2.19E-06 : 3.68E-04 : 5.31E-09 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--4-________--+__-__+
CHILD
- 1.07E-06 : 3.51E-07 : 4.96E-06 : 1.74E-06 : 2.78E-06 : 5.56E-04 : 6.24E-09 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COWM ILK:
ADULT
- 2.55E-05 1.41E-05 4.05E-05 4.45E-05 7.58E-05 1.42E-02 4.70E-08 0.OOE+00
_______+_
+_________-+_______
__-+_____
___-+___
____--+___
____--+__________+__________+
TEEN
- 4.23E-05 : 1.90E-05 : 7.35E-05 : 7.90E-05 : 1.35E-04 : 2.25E-02 : 9.72E-08 : 0.OOE+00 s
-________+__________+__________+__________+__________+__________+__________+_----_____+_+__+______
CHILD
- 7.82E-05 : 1.52E-05 : 1.79E-04 : 1.38E-04 : 2.25E-04 : 4.45E-02 : 1.49E-07 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+-+-_____+__+______
INFANT : 1.48E-04 : 1.51E-05 : 3.62E-04 : 3.37E-04 : 3.91E-04 : 1.08E-01 : 2.70E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK:
ADULT
- 3.13E-05 1.80E-05 s 5.76E-05 5.42E-05 9.12E-05 : 1.71E-02 1.41E-07 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_---____+____________+
TEEN
- 5.16E-05 : 2.43E-05 : 1.05E-04 : 9.62E-05 : 1.63E-04 : 2.70E-02 : 2.91E-07 : 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_---________-________+
CHILD
- 9.52E-05 : 1.95E-05 : 2.54E-04 : 1.68E-04 : 2.70E-04 : 5.35E-02 : 4.48E-07 : O.00E+00
-________+__________+__________+__________+__________+__________+__________+_---4.-______-+-+___-_
INFANT : 1.80E-04 : 1.93E-05 : 5.08E-04 : 4.08E-04 : 4.70E-04 : 1.30E-01 : 8.10E-07 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT
- 2.03E-06 6.61E-06 : 3.44E-06 : 4.37E-06 : 7.50E-06 : 1.10E-03 : 2.05E-05 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+____+___+-________
TEEN
- 2.67E-06 : 3.29E-05 : 4.85E-06 : 6.02E-06 : 1.03E-05 : 1.38E-03 : 3.52E-05 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--________+____-____+
CHILD
- 2.93E-06 : 2.72E-04 6.60E-06 5.93E-06 9.72E-06 1.61E-03 : 3.14E-05 : 0.OOE+00
___ +__________+__________+__________+__________+__________+__________+___--_______+-_________
INFANT
- 2.11E-06 : 2.39E-04 : 5.08E-06 : 5.52E-06 : 6.41E-06 : 1.48E-03 : 3.19E-05 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-_+_________
TABLE 3. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-JUNE 2004 (CONTINUED)
SPECIAL LOCATION NO.
3 A Nearest Resident AT
.90 MILES NW ANNUAL BETA AIR DOSE a 2.37E-04 MILLRADS ANNUAL GAMMA AIR DOSE a 3.38E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
PLUME
- 2.27E-04 : 2.27E-04 : 2.27E-04 : 2.27E-04 : 2.27E-04 : 2.27E-04 : 2.29E-04 : 4.74E-04
_________+_-4________+__________+__________+_________+__________+__________+_--________+____-____+
GROUND
- 2.98E-06 : 2.98E-06 : 2.98E-06 : 2.98E-06 : 2.98E-06 : 2.98E-06 : 2.98E-06 : 3.49E-06
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT 8.45E-06 1.09E-05 5.31E-05 1.26E-05 2.14E-05 4.06E-03 1.52E-08 O.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+_____-___________+
TEEN
- 1.22E-05 : 1.30E-05 : 8.59E-05 : 1.90E-05 : 3.24E-05 s 5.46E-03 : 2.84E-08 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--________+____-______
CHILD
- 2.30E-05 : 1.02E-05 s 2.06E-04 : 3.21E-05 : 5.22E-05 : 1.05E-02 : 4.32E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT
- 2.13E-07 : 2.08E-07 6.92E-07 3.45E-07 5.74E-07 1.09E-04 1.22E-09 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--____+___+____-____+
TEEN
- 1.61E-07 : 1.27E-07 : 5.74E-07 : 2.80E-07 : 4.69E-07 : 7.90E-05 : 1.16E-09 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_---________-+-+__-___
CHILD
- 2.30E-07 : 7.56E-08 : 1.07E-06 : 3.73E-07 : 5.96E-07 : 1.19E-04 : 1.36E-09 : 0.00Z+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
I ADULT
- 5.46E-06 3.02E-06 8.70E-06 : 9.55E-06 1.63E-05 : 3.05E-03 s 1.03E-08 s 0.OOE+00 s
+----------+----------+----------+----------+-----_____+__-_______+
TEN
- 9.07E-06 : 4.07E-06 : 1.58E-05 : 1.70E-05 : 2.90E-05 : 4.83E-03 : 2.12E-08 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+-_______+_________+
CHILD
- 1.68E-05 : 3.26E-06 : 3.84E-05 : 2.96E-05 : 4.82E-05 : 9.55E-03 : 3.26E-08 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---________+_________+
INFANT : 3.17E-05 : 3.23E-06 : 7.78E-05 : 7.22E-05 : 8.38E-05 : 2.32E-02 : 5.90E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 6.71E-06 : 3.85E-06 1.24E-05 1.16E-05 1.96E-05 3.66E-03
- 3.07E-08 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_---________+_________
TEEN
- 1.11E-05 : 5.21E-06 : 2.25E-05 : 2.06E-05 : 3.49E-05 : 5.79E-03 : 6.35E-08 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--+-_______+_________
CHILD
- 2.04E-05 : 4.18E-06 : 5.46E-05 : 3.60E-05 : 5.80E-05 : 1.15E-02 : 9.77E-08 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+________+________+
INFANT : 3.85E-05 : 4.14E-06 : 1.09E-04 : 8.76E-05 : 1.01E-04 : 2.79E-02 : 1.77E-07 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--________+____-____+
INHAL ADULT
- 5.38E-07 : 1.83E-06 s 9.06E-07 1.16E-06 1.96E-06 2.84E-04 5.37E-06 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_---+-__+____-+____-__
TEEN
- 7.09E-07 : 8.66E-06 : 1.28E-06 : 1.59E-06 : 2.70E-06 : 3.58E-04 : 9.21E-06 : 0.OOE+00 s
_________+__________+__________+__________+__________+__________+__________+_--+________+-________
CHILD
- 7.80E-07 : 7.03E-05 : 1.74E-06 : 1.57E-06 : 2.54E-06 : 4.17E-04 : 8.22E-06 : 0.OOE+00
_________+______
___+__
+_____
____+
__+___
___+_--+-
+
+
+__-
+
INFANT : 5.62E-07 : 6.19E-05 : 1.34E-06 : 1.46E-06 : 1.68E-06 : 3.82E-04 : 8.35E-06 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+_--________+_________+
TABLE 3. DOSES TO MAXIMUM INDIVIDUAL (MREM),
JANUARY-JUNE 2004 (CONTINUED)
SPECIAL LOCATION NO.
4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE -
1.98E-04 MILLRADS ANNUAL GAMMA AIR DOSE -
3.32E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
PLUME
- 2.23E-04 : 2.23E-04
- 2.23E-04 s 2.23E-04 : 2.23E-04 : 2.23E-04 : 2.25E-04 : 4.32E-04
________-+__________+__________+__________+_________+__________+__________+_--________+____-____+
GROUND
- 2.75E-07 : 2.75E-07 : 2.75E-07 : 2.75E-07 : 2.75E-07 : 2.75E-07 : 2.75E-07 : 3.21E-07
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I
ADULT
- 6.31E-07 9.69E-07 : 4.72E-06 9.04E-07 1.52E-06 2.86E-04 2.84E-09 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
TEEN
- 9.07E-07 : 1.15E-06 : 7.53E-06 : 1.37E-06 : 2.29E-06 : 3.85E-04 : 5.32E-09 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---______+__-+___-__+
CHILD
- 1.72E-06 : 9.04E-07 : 1.79E-05 : 2.31E-06 : 3.70E-06 : 7.38E-04 : 8.09E-09 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT 1.62E-08 1.96E-08 6.17E-08 2.55E-08 : 4.09E-08 : 7.68E-06 2.29E-10 :0.00E+00
________-+__________+__________+__________+_________+__________+__________+_--+-+-+-_____-+__-__+
TEEN
- 1.20E-08 : 1.20E-08 : 5.04E-08 : 2.07E-08 : 3.34E-08 : 5.56E-06 : 2.17E-10 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--_+_____++____-____+
CHILD
- 1.69E-08 : 7.21E-09 : 9.26E-08 s 2.76E-08 : 4.24E-08 : 8.40E-06 : 2.55E-10 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK:
s s
ADULT
- 3.93E-07 s 2.22E-07 s 6.65E-07 6.85E-07 1.15E-06 2.15E-04 1.92E-09 0.OOE+00
_________+__-_______+_________-_+___--
____+__________+___-__--
_+_____-____+________-_+_______+--
TEEN s 6.48E-07 s 3.OOE-07 s 1.20E-06 s 1.22E-06 s 2.05E-06 s 3.40E-04 s 3.98E-09 s 0.00E+00
_________+_-_________+__________+__________+_________+__________+__________+_--________+__________
CHILD s 1.19E-06 s 2.40E-07 s 2.91E-06 s 2.12E-06 s 3.41E-06 s 6.74E-04 s 6.11E-09 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---________+_________
INFANT s 2.25E-06 s 2.38E-07 s 5.81E-06 s 5.16E-06 s 5.94E-06 : 1.64E-03 : 1.11E-08 s 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK s I
ADULT
- 4.96E-07 2.82E-07 9.84E-07 : 8.52E-07 : 1.39E-06 2.58E-04 5.76E-09 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+-4.-4.-+-_________+
TEEN
- 8.04E-07 : 3.82E-07 : 1.77E-06 s 1.51E-06 s 2.48E-06 s 4.08E-04 s 1.19E-08 s 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--4.-4.-4.-+_____+___+
CHILD s 1.46E-06 : 3.07E-07 s 4.29E-06 s 2.64E-06 : 4.13E-06 : 8.09E-04 : 1.83E-08 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--4________+_________
INFANT : 2.75E-06 : 3.05E-07 : 8.38E-06 : 6.37E-06 : 7.17E-06 : 1.97E-03 : 3.31E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL I
I ADULT 7.91E-08 3.31E-07 1.30E-07 : 1.66E-07 2.51E-07 : 3.30E-05 5.64E-07 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+-________________+
TEEN
- 1.05E-07
- 9.26E-07 : 1.82E-07 s 2.29E-07 s 3.46E-07 s 4.16E-05 s 9.58E-07 s 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--+________+-________
CHILD
- 1.19E-07 : 5.76E-06 s 2.46E-07 s 2.25E-07 s 3.25E-07 s 4.85E-05 s 8.49E-07 s 0.00E+00
________-+__________+__________+__________+_________+__________+__________+_--________+____-____+
INFANT s 8.55E-08 s 5.03E-06 s 1.86E-07 s 2.10E-07 s 2.14E-07 s 4.45E-05 s 8.47E-07 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+-+-4.-+-_________+
TABLE 3. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-JUNE 2004 (CONTINUED)
SPECIAL LOCATION NO.
5 A Nearest Garden AT 1.20 MILES SE ANNUAL BETA AIR DOSE = 1.19E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 1.67E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+__________+__________+__________+_________+__________+__________+_---________+_________
PLUME
- 1.12E-04 : 1.12E-04 : 1.12E-04 s 1.12E-04 s 1.12E-04 s 1.12E-04 s 1.13E-04 s 2.36E-04
________-+__________+__________+__________+_________+__________+__________+_---________+-+___-__+
GROUND s 2.07E-06 : 2.07E-06 s 2.07E-06 s 2.07E-06 s 2.07E-06 s 2.07E-06 s 2.07E-06 s 2.42E-06
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET s
s ADULT 5.62E-06 7.44E-06 3.61E-05 8.34E-06 1.42E-05 2.68E-03 : 1.20E-08 : 0.OOE+00
-+__________+__
_______+_____
____+_______
__+__________
__________+_--+-
+
+
+__-
+
TEEN s 8.11E-06 s 8.87E-06 s 5.83E-05 s 1.26E-05 : 2.14E-05 : 3.61E-03 : 2.25E-08 : 0.OOE+00
-+__________+__________+__________+
_________+__________+__________+_--+-__+_____+_+-_
_+
CHILD
- 1.53E-05 : 6.93E-06 : 1.40E-04 : 2.13E-05 : 3.45E-05 : 6.92E-03 s 3.42E-08 s 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT 1.42E-07 1.43E-07 s 4.72E-07 2.29E-07 s 3.80E-07 7.20E-05 9.69E-10 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+-________-+___-__+
TEEN
- 1.07E-07 : 8.70E-08 : 3.90E-07 s 1.86E-07 s 3.10E-07 s 5.22E-05 s 9.17E-10 s 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+-________+-+__-__+
CHILD
- 1.52E-07 s 5.20E-08 : 7.24E-07 s 2.48E-07 s 3.94E-07 s 7.87E-05 s 1.08E-09 s 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK:
s s
s s
s ADULT
- 3.62E-06 s 2.00E-06 5.80E-06 6.32E-06 1.07E-05 2.01E-03 8.12E-09 s 0.OOE+00 s TEEN 6.OOE-06 2.70E-06 1.0E-05 1.12E-05 1.92E-05 3.19E-03 : 1.68E-08 : 0.OOE+00 s CHILD s 1.11E-05 s 2.17E-06 s 2.56E-05 s 1.96E-05 s 3.18E-05 s 6.31E-03 s 2.58E-08 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+__+__+_++-________
INFANT s 2.10E-05 s 2.15E-06 s 5.17E-05 s 4.78E-05 : 5.54E-05 : 1.53E-02 : 4.67E-08 s 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK s s
s s
ADULT
- 4.46E-06 : 2.56E-06 : 8.30E-06 7.71E-06 1.29E-05 2.42E-03 2.43E-08 s 0.OOE+00
-+__________+__________+__________+
_________+__________+__________+_--+-
+
+
-+
+-__+-_
_+
TEEN s 7.34E-06 : 3.46E-06 s 1.50E-05 s 1.37E-05 : 2.31E-05 : 3.82E-03 : 5.03E-08 : 0.OOE+00
-+__________+__________+__________+
_________+__________+__________+_--+
-______+_+_+-_
_+
CHILD
- 1.35E-05 : 2.77E-06 : 3.65E-05 : 2.39E-05 : 3.83E-05 : 7.57E-03 : 7.73E-08 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---____+_+___+___-__+
INFANT : 2.55E-05 : 2.75E-06 : 7.28E-05 : 5.81E-05 : 6.67E-05 : 1.84E-02 : 1.40E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL s
s s
s s
ADULT 2.85E-07 9.61E-07 s 4.79E-07 s 6.11E-07 s 1.04E-06 s 1.51E-04 2.84E-06 s 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---+-__+____-+___-__+
TEEN
- 3.75E-07 : 4.58E-06 : 6.75E-07 s 8.42E-07 : 1.43E-06 s 1.90E-04 : 4.88E-06 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---+-______+-+___-__+
CHILD
- 4.12E-07 : 3.73E-05 : 9.20E-07 : 8.29E-07 : 1.35E-06 : 2.21E-04 : 4.35E-06 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+-+-+-+-___-+__-__+
INFANT : 2.97E-07 : 3.28E-05 : 7.07E-07 : 7.73E-07 : 8.88E-07 s 2.03E-04 : 4.42E-06 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--_+______+____-_____
TABLE 4.
DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-SEPTEMBER 2004 SPECIAL LOCATION NO.
1 A Site Boundary AT
.69 MILES NNW ANNUAL BETA AIR DOSE -
6.06E-05 MILLRADS ANNUAL GAMMA AIR DOSE a 1.16Z-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_______-_+-_________+______-___+_________-+-_________+__________+_________-+________-_+________-_+
PLUME
- 7.73K-05 : 7.73K-05 : 7.73E-05 : 7.73E-05 : 7.73E-05 : 7.73E-05 : 7.79E-05 : 1.43E-04
_________+_______-__+________-_+________-_+________-_+________-_+_________-+________-_+________-_+
GROUND
- 2.11E-04
- 2.11E-04 : 2.11E-04 : 2.11E-04 : 2.11E-04 : 2.11E-04 : 2.11E-04 : 2.48E-04
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET z
s I
ADULT s 2.85E-05 7.57E-05 2.63E-04 : 3.39E-05 : 5.58E-05 1.06E-02 8.74E-10 O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN z 4.26E-05 : 8.79E-05 : 4.34E-04 : 5.12E-05 s 8.45E-05 z 1.43E-02 : 1.59E-09 z O.OOE+00 CHILD s 8.46E-05 s 6.55E-05 s 1.06E-03 s 8.62E-05 : 1.36E-04 s 2.73E-02 : 2.38E-09 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT
.s s
ADULT 1.39E-06s 7.68E-06s 2.98E-06s 1.24E-06s 1.49E-06s 2.85E-04 3.31E-li O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN s 1.09E-06 s 4.19E-06 s 2.50E-06 s 9.95E-07 s 1.22E-06 s 2.06E-04 s 3.14E-li s O.OOE+00 CHILD s 1.65E-06 s 2.16E-06 s 4.72E-06 s 1.28E-06 s 1.55E-06 z 3.11E-04 s 3.67E-li s O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK s s
s ADULT s 1.45E-05s 1.04E-05s 2.84E-05s 2.48E-05s 4.23E-05s 7.96E-03 3.10E-li O.OOE+00
+-----
+-
+-
+----------__+_-________
+________-_+
TEEN
- 2.42E-05 : 1.37E-05 : 5.18E-05 : 4.40E-05 : 7.55E-05 s 1.26E-02 : 6.40E-ll : O.OOKE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
CHILD
- 4.51E-05 : 1.08E-05 : 1.27E-04 : 7.66E-05 s 1.25E-04 s 2.49E-02 s 9.80E-ll z O.OOE+00 INFANT : 8.52E-05 : 1.05E-05 : 2.55E-04 : 1.87E-04 : 2.18E-04 : 6.06E-02 : 2.37E-10 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK s s
s s
ADULT s 1.74E-05s 1.23E-05s 4.41E-05s 2.96E-05s 5.08E-05s 9.55E-03 3.71E-12 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN
- 2.92E-05 : 1.66E-05 : 8.07E-05 : 5.26E-05 : 9.06E-05 : 1.51E-02 : 7.68E-12 : O.OOE+00 CHILD
- 5.47E-05 : 1.33E-05 : 1.98E-04 : 9.17E-05 : 1.51E-04 : 2.99E-02 : 1.18E-11 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INFANT : 1.04E-04 : 1.32E-05 : 3.93K-04 s 2.24E-04 s 2.62E-04 a 7.27E-02 s 2.84E-ll a O.OOE+00 INHAL I
s s
s s
a s
ADULT s 1.12E-06 s 6.84E-06 a 2.21E-06 a 2.34E-06 a 3.92E-06 a 5.65E-04 a 3.01E-05 a O.OOE+00 TEEN a 1.47E-06 a 3.53E-05 a 3.12E-06 a 3.23E-06 a 5.40E-06 a 7.12E-04 a 4.98E-05 a O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
CHILD a 1.63E-06 s 2.95E-04 a 4.26E-06 a 3.18E-06 a 5.07E-06 a 8.29E-04 a 4.35E-05 s O.00E+00 INFANT a 1.17E-06 s 2.60E-04 a 3.20E-06 a 2.96E-06 a 3.35E-06 a 7.60E-04 a 4.09E-05 s O.OOE+00
_________+______-___+_________-+_______-__+_________-+________-_+________-_+________-_+________-_+
TABLE 4. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-SEPTEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
2 A Site Boundary AT
.67 MILES N
ANNUAL BETA AIR DOSE -
5.67E-05 MILLRADS ANNUAL GAMMA AIR DOSE a 1.08E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_________+__________+__________+__________+__________+__________+__________+__________+__________+
PLUME
- 7.23E-05 : 7.23K-05 : 7.23K-05 : 7.23E-05 : 7.23E-05 : 7.23E-05 : 7.29E-05 : 1.34E-04 GROUND
- 2.04E-04 : 2.04E-04 : 2.04E-04 : 2.04E-04 : 2.04E-04 : 2.04E-04 : 2.04E-04 : 2.40E-04
-________+______-___+_________-+_________-+________-_+________-_+_________-+________-_+________-_+
VEGET ADULT 2.76E-05 7.41E-05 2.56E-04 3.28E-05 5.40E-05 1.02E-02 1.09E-09 O.OOE+00 TEEN
- 4.12E-05 : 8.61E-05 : 4.23E-04 : 4.95E-05 : 8.17E-05 : 1.38E-02 : 1.99E-09 0.OOE+00 CHILD
- 8.21E-05 : 6.42E-05 : 1.03E-03 : 8.33E-05 : 1.32E-04 : 2.65E-02 : 2.98E-09 : O.OOE+00 MEAT I
s a
s a
ADULT s 1.34E-06 a 7.45E-06 a 2.90E-06 s 1.20E-06 a 1.44E-06 a 2.75E-04 : 4.14E-11 a O.OOE+00 TEEN a 1.05E- 06s 4.06E-06 a 2.44E-06 a 9.62E-07 a 1.18E-06 a 2.OOE-04 a 3.92E-11 a 0.OOE+00 CHILD a 1.60E-06 a 2.10E-06 a 4.60E-06 a 1.24E-06 a 1.50E-06 a 3.01E-04 a 4.58E-ll a O.OOE+00 COW MILK a s
a a
a a
s ADULT s 1.40E-05 a 1.01E-05s 2.75E-05 a 2.39K-05 a 4.09E-05 a 7.70E-03 a 3.87E-ll O.OOE+00s O
+------
+-------------
+-----
+--------------------+_-________+
TEEN a 2.34K-OS a 1.33K-05 a 5.03K-OS a 4.25K-05 a 7.30E-05 a 1.22E-02 a 8.00E-11 : O.OOE+00 a CHILD
- 4.36E-05 : 1.04E-05 : 1.23E-04 : 7.41E-05 : 1.21E-04 : 2.41E-02 : 1.22E-10 : O.OOE+00 a
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INFANT a 8.24E-05 a 1.02E-05 a 2.47E-04 a 1.81E-04 a 2.11E-04 a 5.86E-02 a 2.96E-10 a O.OOE+00 GOATMILK a a
a a
a s
a a
ADULT a 1.69E-05 s 1.19E-05 a 4.28E-05 s 2.86E-05 a 4.91E-05 s 9.24E-03 s 4.64E-12 a 0.00E+00 a TEEN a 2.82E-05 a 1.61E-05 a 7.82E-05 a 5.09E-05 a 8.76E-05 a 1.46E-02 a 9.60E-12 a O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
CHILD a 5.29E-05 a 1.29E-05 a 1.92E-04 s 8.87E-05 a 1.46E-04 a 2.89E-02 a 1.47E-li a O.OOE+00 INFANT a 1.00E-04 a 1.28E-05 a 3.81E-04 a 2.17E-04 a 2.53E-04 a 7.03E-02 a 3.55E-li a O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL a
s a
a a
a a
a ADULT a 1.34E-06 a 8.28E-06 a 2.67E-06 a 2.82E-06 a 4.73E-06 a 6.85E-04 a 3.68E-05 a O.OOE+00 a
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN a 1.77E-06 a 4.32E-05 a 3.78E-06 a 3.88E-06 a 6.53E-06 a 8.63E-04 a 6.09E-05 a O.OOE+00 a CHILD a 1.95E-06 a 3.62E-04 a 5.16E-06 a 3.82E-06 : 6.13E-06 : 1.OOE-03 : 5.33E-05 : O.OOE+00 a
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INFANT : 1.40E-06 : 3.19E-04 : 3.87E-06 : 3.55E-06 : 4.05E-06 : 9.21E-04 : 5.01E-05 : O.OOE+00 a
-________+______-___+__________+_________-+________-_+________-_+________-_+________-_+________-_+
TABLE 4. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-SEPTEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
3 A Nearest Resident AT
.90 MILES NW ANNUAL BETA AIR DOSE -
5.28K-05 MILLRADS ANNUAL GAMMA AIR DOSE = 1.01E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+__________+-
+___
_+
__-----+
-___+_--__
_+
PLUME
- 6.73E-05 : 6.73B-05
- 6.73E-05 : 6.73E-05 s 6.73E-05 s 6.73E-05 s 6.79E-05 : 1.24E-04
+-
+-------------------+-
+
+--
GROUND
- 6.42E-05 : 6.42K-05
- 6.42K-05 : 6.42E-05 s 6.42E-05 s 6.42E-05 s 6.42E-05 s 7.54E-05
+-
+-------------------+-
+
+
+--
VEGET s
ADULT
- 8.68E-06 : 2.39E-05 : 8.12E-05 1.02E-05 1.68E-05 3.20E-03 5.39E-10 O.OOE+00
+-
+-------------------+-
+
+
+--
TEEN
- 1.29E-05 : 2.77E-05 s 1.34E-04
- 1.55E-05 : 2.55E-05 : 4.31E-03
- 9.79E-10 : O.OOE+00
+-
+-------------------+-
+
+
+--
CHILD
- 2.58E-05 : 2.07E-05 : 3.27E-04 : 2.60E-05 : 4.11E-05 : 8.26E-03 : 1.47E-09 2 O.OOE+00
+-
+-------------------+-
+
+
MEAT 2
s s
ADULT 4.19E-07 2.34E-06 9.26E-07 3.74E-07 4.50E-07 : 8.60E-05 s 2.04E-ll O.OOE+00
-________+__________+-
+___
_+
__--+---+
_+_--____
_+
TEEN s 3.29E-07 s 1.28E-06 s 7.79E-07 s 3.OOE-07 2 3.68E-07 s 6.23E-05 s 1.93E-ll 0.OOE+00
+-
+-------------------+-
+
+
+--
CHILD 2 5.00E-07 2 6.62E-07 : 1.47E-06 2 3.87E-07 : 4.67E-07 s 9.40E-05 s 2.26E-11 s O.OOE+00
+-----------+--+----+----------------------+----+---
COW MILK:
s s
2 2
ADULT
- 4.37E-06 : 3.17E-06 z 8.65K-06 2 7.47E-06 1.28E-05s 2.40E-03 1.91-li O.OOKE+00
+----------------------------------------+
+-----+----
+----+
TEEN
- 7.30E-06 s 4.20E-06 s 1.58E-05 s 1.33E-05s 2.28E-05 s 3.80E-03 3.95E-l O.OOE+00
-________+__________+-
+___
_+
__----+
-+
-___+_--__+
CHILD
- 1.36E-05 : 3.29K-06 : 3.86E-05 : 2.31E-05 : 3.79E-05 : 7.53E-03 : 6.04E-li s O.OOE+00
+-
+-------------------+-
+
+
+---
INFANT : 2.57E-05 : 3.23E-06 : 7.77E-05 : 5.66E-05 : 6.59E-05 : 1.83E-02 : 1.46E-10 : 0.00E+00 2
-________+__________+-
+___
_+
__--+-+
-+
-+
_+_--__
_+
GOATMILK s 2 s 2
ADULT s 5.27E-06s 3.74E-06 1.34E-05 8.94E-06 : 1.53E-05 : 2.88E-03 : 2.29E-12 O.OOE+00
-+------------+-
+----------------------------+- -+
+
+--
TEEN
- 8.82E-06 : 5.06E-06 2 2.46E-05 s 1.59E-05 a 2.73E-05 s 4.56E-03 : 4.74E-12 : O.OOE+00 CHILD
- 1.65E-05 a 4.05E-06 2 6.03E-05 a 2.77E-05 : 4.55E-05 : 9.04E-03 : 7.25B-12 : O.OOE+00
-________+__________+-
+___
_+
__-----+
-___+_--__
_+
INFANT 2 3.13E-05 a 4.03E-06 s 1.20E-04 : 6.77E-05 : 7.91E-05 : 2.20E-02 : 1.75E-11 : 0.00E+00 a
+-
+----------------------------+-
-+
-+
+--
INHAL 2
2 2
2 ADULT s 2.79E-07 a 1.75E-06 s5.14E-07 : 5.76E-07 8.95E-07 a 1.24E-04 6.92E-06 s 0.00E+00 2
-________+__________+--+-
+_____+___
_+__________+__--+-+___+_+__--_
+
TEEN
- 3.70E-07 : 8.35E-06 : 7.26E-07 s 7.93E-07 2 1.23E-06 s 1.56E-04 s 1.15E-05 : O.OOE+00
-________+__________+--+-
+_____+___
_+__________+__--+-+_____+__--_
+
CHILD
- 4.16E-07 : 6.80E-05 : 9.92E-07 s 7.80E-07 2 1.16E-06 a 1.82E-04 s 1.00E-05 : O.OOE+00 INFANT s 2.98E-07 a 5.99E-05 a 7.47E-07 : 7.25E-07 : 7.65E-07 : 1.66E-04 : 9.45E-06 : O.OOE+0
-________+_____-____+________-_+_________-+__________+__________+__________+__________+_________-+
TABLE 4.
DOSES TO MAXIMUM INDIVIDUAL (MREM),
JULY-SEPTEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
4 A
Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE. 3.72E-05 MILLRADS ANNUAL GAMMA AIR DOSE -
7.08E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-_________+__________+__________+_________+__________+__________+__________+_--________+____-____+
PLUME
- 4.74E-05 : 4.74B-05 : 4.74E-05 : 4.74E-05 : 4.74E-05 : 4.74E-05 : 4.78B-05 I 8.76-05s GROUND
- 4.65E-06 : 4.65E-06 : 4.65E-06 : 4.65E-06 : 4.658-06 : 4.65E-06 : 4.65E-06 : 5.47E-06
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT 6.31E-07 : 1.81E-06 6.02E-06 : 7.37E-07 : 1.21E-06 2.30E-04 6.27K-11 O.O+00
-________+__________+__________+__________+__________+__________+__________+_---+-+-______-+__-__+
TEEN
- 9.428-07 : 2.11E-06 : 9.93E-06 : 1.l1E-06 : 1.84E-06 : 3.10E-04 : 1.14Z-10 : O.O+00 CHILD
- 1.88Z-06 : 1.58E-06 : 2.42K-05 : 1.878-06 : 2.96E-06 : 5.95E-04 : 1.71E-10 : O.O+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT I
ADULT
- 3.03K-08 1.72E-07 6.93K-08 : 2.70Z-08 3.24K-08 : 6.19Z-06 2.37E-12 : 0.O+00
-_________+_________+_________+__________+_________+_____---_+__+-__________+_______--_--+________
TEEN
- 2.388-08 : 9.40K-08 : 5.83K-08 : 2.16Z-08 : 2.65K-08 : 4.49Z-06 : 2.25Z-12 : 0.OOE+00 CHILD
- 3.62K-08 : 4.888-08 : 1.108-07 : 2.79K-08 : 3.36K-08 : 6.778-06 : 2.63E-12 : 0.OO+00s
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK s I
ADULT
- 3.14Z-07 : 2.31E-07 6.30K-07 : 5.37E-07 : 9.19Z-07 : 1.73K-04 : 2.22E-12 : 0.008+00:
00-
+-------____-------+______-_
TEEN
- 5.26E-07 : 3.06Z-07 s 1.15Z-06 : 9.54Z-07 : 1.64E-06 : 2.74Z-04 : 4.59Z-12 : 0.O+00 CHILD
- 9.81E-07 : 2.408-07 : 2.818-06 : 1.668-06 : 2.728-06 : 5.428-04 : 7.02Z-12 : 0.O+00
-_________+__________+__________+_________+__________+__________+__________+_--+-________--+-_____
INFANT : 1.85Z-06 : 2.35E-07 : 5.66Z-06 : 4.07Z-06 : 4.74Z-06 : 1.32E-03 : 1.70K-11 : 0.O+00:
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 3.808-07 : 2.72Z-07 : 9.81Z-07 : 6.43K-07 : 1.10K-06 : 2.08E-04 : 2.66Z-13 : 0.O+00 :
TEEN
- 6.35E-07 : 3.67Z-07 : 1.80Z-06 : 1.14Z-06 : 1.97E-06 : 3.28E-04 : 5.51K-13 : 0.O+00
-________+__________+__________+__________+__________+__________+__________+_--________+__________
CHILD
- l.19Z-06 : 2.94E-07 : 4.41E-06 : 1.99Z-06 : 3.27Z-06 : 6.50E-04 : 8.428-13 : 0.008+00
-________+__________+__________+__________+__________+__________+__________+_--________+_________+
INFANT : 2.26K-06 : 2.92Z-07 : 8.74E-06 : 4.87Z-06 : 5.69Z-06 : 1.58E-03 : 2.048-12 : 0.008+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT
- 6.79K-08 : 3.69Z-07 : 9.90K-08 : 1.33Z-07 : 1.63E-07 1.89Z-05 : 9.37Z-07 : 0.008+00 TEEN
- 9.13E-08 : 1.14E-06 : 1.40Z-07 : 1.838-07 : 2.25E-07 : 2.37E-05 : 1.54Z-06 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
CHILD
- 1.07K-07 : 7.54K-06 : l.91E-07 : 1.80K-07 : 2.118-07 : 2.76K-05 : 1.34E-06 : 0.008+00 INFANT : 7.64K-08 : 6.62E-06 : 1.45K-07 : 1.67K-07 : 1.39Z-07 : 2.53K-05 : 1.24K-06 : O.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_---________--+-+__-_+
TABLE 4. DOSES TO MAXIMUM INDIVIDUAL (MREM),
JULY-SEPTEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
5 A Nearest Garden AT 1.20 MILES SE ANNUAL BETA AIR DOSE a 6.06E-06 MILLRADS ANNUAL GAMMA AIR DOSE a 1.16E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+__________+__________+__________+_________+__________+__________+_--4________+-_______+
PLUME
- 7.73E-06 : 7.73E-06
- 7.73E-06 : 7.73E-06 : 7.73E-06 : 7.73E-06 : 7.79E-06 : 1.43E-05
________-+__________+__________+__________+_________+__________+__________+_--________+____-____+
GROUND
- 1.36E-05
- 1.36E-05
- 1.36E-05 : 1.36E-05 : 1.36E-05 : 1.36E-05
- 1.36E-05 : 1.60E-05
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I :
ADULT 1.85E-06 4.92E-06
- 1.71E-05 : 2.19E-06 : 3.61E-06 : 6.85E-04 : 6.27E-11 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+_++__+__+-________
TEEN
- 2.76E-06 : 5.71E-06
- 2.82E-05 : 3.31E-06 : 5.47E-06 : 9.23E-04
- 1.14E-10 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_----_______+_________+
CHILD
- 5.48E-06
- 4.26E-06
- 6.87E-05 : 5.57E-06 : 8.81E-06 : 1.77E-03
- 1.71E-10 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT 8.97E-08 4.97E-07 : 1.93E-07 : 8.02E-08 9.64E-08 1.84E-05
- 2.37E-12 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---___+_+_+__-+__-__+
TEEN
- 7.03E-08 : 2.71E-07 : 1.62E-07 : 6.44E-08 : 7.87E-08 : 1.33E-05
- 2.25E-12 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--________+__________+
CHILD
- 1.07E-07 : 1.40E-07 : 3.06E-07 : 8.31E-08 : 1.OOE-07 : 2.01E-05 s 2.63E-12 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
I:t ADULT
- 9.35E-07 : 6.71E-07 : 1.84E-06 : 1.60E-06 : 2.74E-06 : 5.15E-04 : 2.22E-12 2 0.OOE+00 :
+-------------+----------+----------+----------+----------+----------+-___________
TEEN
- 1.56E-06 : 8.90E-07 : 3.36E-06 : 2.84E-06 : 4.88E-06 : 8.15E-04 : 4.59E-12 : O.OOE+00 CHILD
- 2.92E-06 : 6.97E-07 : 8.21E-06 : 4.96E-06 : 8.12E-06 : 1.61E-03 : 7.02E-12 : O.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--________+__________
INFANT : 5.51E-06 : 6.83E-07 : 1.65E-05 : 1.21E-05 : 1.41E-05 : 3.92E-03 : 1.70E-11 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK
- ADULT
- 1.13E-06 7.97E-07 2.85E-06 1.92E-06 ; 3.28E-06 6.18E-04 2.66E-13 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--________+__________
TEEN
- 1.89E-06 : 1.08E-06 : 5.22E-06 : 3.40E-06 : 5.86E-06 : 9.78E-04 : 5.51E-13 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--________+__________
CHILD
- 3.54E-06 : 8.62E-07 : 1.28E-05 : 5.93E-06 : 9.74E-06 : 1.94E-03 : 8.42E-13 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--________+_______+__
INFANT : 6.70E-06 : 8.57E-07 : 2.55E-05 : 1.45E-05 : 1.69E-05 : 4.70E-03 : 2.04E-12 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT
- 1.60E-07 9.79E-07 3.20E-07 3.38E-07 5.70E-07 8.25E-05 4.36E-06 0.OOE+00
_ _ _ _ _ _ _ _ _ + _
_ _ _ _ _ _ _ + _ _ _ _ _ _ _ _ _ _ + _ _ _ _ _ _ _ _ _ _ + _
_ _ _ _ _ _ _ _ + _ _ _ _ _ _ _ _ _ _ + _ _ _ _ _ _ _ _ _ _ + __-
_ _ _ _ _ _ _ + _ _ _ _ _ _ _ _ _
TEEN
- 2.11E-07 : 5.11E-06 4.52E-07 4.65E-07 : 7.85E-07 : 1.04E-04 : 7.22E-06 I 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--________+__________
CHILD
- 2.34E-07 : 4.28E-05 : 6.18E-07 : 4.58E-07 : 7.38E-07 : 1.21E-04 : 6.31E-06 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--________+_________+
INFANT : 1-.67E-07 : 3.78E-05 : 4.64E-07 : 4.26E-07 : 4.87E-07 : 1.11E-04 : 5.93E-06 0.OOE+00 :
_________+______-_-___+__________+__________+__________+__________+__________+---_______-________
TABLE 5.
DOSES TO MAXIMUM INDIVIDUAL (MREM),
OCTOBER-DECEMBER 2004 SPECIAL LOCATION NO.
1 A Site Boundary AT
.69 MILES NNW ANNUAL BETA AIR DOSE = 1.19E-04 MILLRADS ANNUAL GAMMA AIR DOSE
- 1.39E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_________+__________+__________+__________+__________+__________+__________+__________+__________+
PLUME i 9.26E-05 s 9.26E-05 : 9.26E-05 : 9.26K-05 : 9.26E-05 s 9.26E-05 s 9.38E-05 s 2.05E-04 GROUND
- 4.43E-04 s 4.43E-04 s 4.43E-04 : 4.43E-04 : 4.43E-04 : 4.43E-04 : 4.43E-04 s 5.21E-04
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I
s s
ADULT 6.08E-04 3.33E-03 2.06E-02 s 2.70E-05s 3.06E-05 s 4.62E-03 s5.77E-08 s O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN s 1.OOE-03 s 4.10E-03 s 3.41E-02 s 4.09E-05 s 4.61E-05 s 6.23E-03 s 1.08E-07 s O.OOE+00 CHILD s 2.43E-03 s 3.25E-03 s 8.33E-02 s 6.56E-05 s 7.29E-05 s 1.19E-02 s 1.65E-07 : O.OOE+00 MEAT s
s s
s s
ADULT 9.90E-06 5.04E-05s 2.02E-04 s 6.03E-06 3.88E-06 1.24E-04 4.71E-09 O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN s 8.10E-06 s 2.98E-05 : 1.70E-04 : 4.65E-06 : 2.91E-06 : 9.01E-05 : 4.45E-09 : O.OOE+00 CHILD
- 1.41E-05 s 1.72E-05 : 3.21E-04 : 5.44E-06 : 3.37E-06 : 1.36E-04 s 5.23E-09 : O.OOE+00 COW MILK :
I ADULT
- 4.26E-05 : 1.75E-04 : 9.75E-04 : 2.98E-05 : 3.09E-05 : 3.47E-03 I 3.98E-08 : O.OOE+00 TEEN 7.60E-Os 2.36E-04 1.79E-03 5.10E-05 5.29E-05 : 5.49E-03 : 8.22E-08 I O.OOE+00 CHILD s 1.74E-04 s 1.86E-04 s 4.42E-03 s 8.15E-05 s 8.43E-05 s 1.09E-02 s 1.26E-07 O.00OE+00
-________+__________+__________+__________+__________+__________+__________+_--________+____-_____
INFANT : 3.12E-04 : 2.47E-04 : 8.37E-03 : 1.65E-04 s 1.35E-04 s 2.64E-02 : 2.29E-07 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK s s
s s
s ADULT
- 6.68E-05 3.26E-04 2.03E-03 1.62E-05 : 2.39E-05 : 4.16E-03 : 1.19E-07 O.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN s 1.21E-04 s 4.46E-04 : 3.73E-03 s 2.85E-05 2 4.23E-05 : 6.58E-03 : 2.47E-07 : O.OOE+00 CHILD
- 2.88E-04 : 3.58E-04 : 9.22E-03 : 4.87E-05 : 7.00E-05 : 1.30E-02 s 3.79E-07 s 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_--+-4.-+-+-+-+-______
INFANT s 5.45E-04 s 3.69E-04 s 1.75E-02 s 1.13E-04 s 1.20E-04 s 3.17E-02 : 6.86E-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL s
s s
ADULT 3.43E-06 1.08E-04 9.50E-05s 1.53E-06 2.38E-06 3.46E-04 4.54E-04 O.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_--4____+__++-_______+
TEEN
- 4.81E-06 : 1.23E-04 : 1.35E-04 : 2.09E-06 : 3.26E-06 : 4.34E-04 : 7.77E-04 : O.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_---________---+__-__+
CHILD
- 6.35E-06 : 1.35E-04 : 1.86E-04 : 2.02E-06 : 3.05E-06 : 5.02E-04 : 6.90E-04 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INFANT : 4.21E-06 s 9.39E-05 s 1.22E-04 s 1.81E-06 : 1.99E-06 : 4.60E-04 : 6.41E-04 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+
TABLE 5. DOSES TO MAXIMUM INDIVIDUAL (MREM), OCTOBER-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
2 A Site Boundary AT
.67 MILES N
ANNUAL BETA AIR DOSE. 1.92E-04 MILLRADS ANNUAL GAMMA AIR DOSE. 2.28E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+
PLUME
- 1.52E-04
- 1.52E-04 : 1.52E-04 : 1.52E-04 1.52E-04
- 1.52E-04
- 1.54E-04 : 3.35E-04 :
-________ +__________+__________+__________+__________+__________+__________+-
______+____- ____
GROUND
- 7.76E-04 z 7.76E-04 : 7.76E-04 : 7.76E-04 7.76E-04 : 7.76E-04 : 7.76E-04 : 9.13E-04 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT s 1.06E-03 5.83E-03 : 3.61E-02 4.63E-05 5.30E-05 8.06E-03 7.49E-08 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_---________-+____-___
TEEN
- 1.75E-03 : 7.18E-03 : 5.98E-02 : 7.02E-05 : 7.97E-05 : 1.09E-02 : 1.40E-07 : 0.OOE+00 :
-_________+__________+__________+_________+__________+__________+__________+_---________-+___-___+
CHILD
- 4.25E-03 : 5.69E-03 : 1.46E-01 : 1.13E-04 : 1.26E-04 : 2.08E-02 : 2.13E-07 : O.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT 1.72E-05 8.78E-05 : 3.54E-04 : 1.02E-05 6.57E-06 : 2.17E-04 6.11E-09 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--________+____-____+
TEEN
- 1.41E-05 : 5.21E-05 : 2.98E-04 : 7.88E-06 : 4.92E-06 : 1.57E-04 : 5.78E-09 : 0.OOE+00 :
-________+__________+__________+__________+__________+__________+__________+_---+-______+-+___-__+
CHILD s 2.45E-05 s 3.01E-05 s 5.62E-04 : 9.21E-06 : 5.70E-06 : 2.37E-04 : 6.79E-09 0.OOE+00 s
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK:
I I
s ADULT s 7.38E-05 s 3.04E-04 1.71E-03 : 5.07E-05 : 5.31E-05 6.05E-03 5.16E-08 : 0.OOE+00 :
TEEN
- 1.32E-04 : 4.09E-04 3.14E-03 : 8.68E-05 : 9.09E-05 : 9.57E-03 s 1.07E-07 s 0.OOE+00 :
CHILD
- 3.02E-04 : 3.23E-04 : 7.74E-03 : 1.39E-04 : 1.45E-04 : 1.89E-02 : 1.64E-07 : O.OOE+00 :
_________+______-_--__+_______+________-_+_______-__+________-_+________-_+__________+_____-__-_+
INFANT : 5.44E-04 : 4.26E-04 : 1.47E-02 : 2.82E-04 : 2.32E-04 : 4.60E-02 : 2.97E-07 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 1.16E-04 : 5.71E-04 3.56E-03 : 2.76E-05 : 4.14E-05 7.26E-03 : 1.55E-07 : O.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--________+_______+__
TEEN
- 2.11E-04 : 7.80E-04 : 6.54E-03 : 4.86E-05 : 7.34E-05 : 1.15E-02 : 3.20E-07 : 0.OOE+00 :
______-_-__+________+__________+-__________+__________+__________----______+________-_+________-_+
CHILD
- 5.04E-04 s 6.27E-04 s 1.61E-02 : 8.32E-05 : 1.21E-04 : 2.27E-02 : 4.92E-07 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________-+_-________+_-____-___
INFANT : 9.54E-04 : 6.45E-04 : 3.06E-02 : 1.95E-04 : 2.08E-04 : 5.52E-02 : 8.90E-07 : 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT 5.36E-06 1.70E-04 1.49E-04 2.35E-06 : 3.65E-06 s 5.31E-04 : 7.11E-04 : O.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_--+-+-4.-__+________+
TEEN
- 7.52E-06 : 1.93E-04 : 2.12E-04 : 3.22E-06 : 5.02E-06 : 6.66E-04 : 1.22E-03 0.OOE+00 :
-________+______-___+_________-+________-_+__________-+______-__+__________+_________-+_________-_
CHILD
- 9.93E-06 : 2.12E-04 : 2.91E-04 : 3.12E-06 : 4.69E-06 : 7.70E-04 : 1.08E-03 0.OOE+00 s
_________+__________+__________+________-_-+-_-________+________+__________+__________+-______-4-+
INFANT : 6.57E-06 : 1.47E-04 : 1.92E-04 : 2.78E-06 : 3.06E-06 : 7.06E-04 : 1.OOE-03 0.OOE+00 :
-_________+__________+__________+_________+__________+__________+__________+__--_______+___-_____+
TABLE 5. DOSES TO MAXIMUM INDIVIDUAL (MREM),
OCTOBER-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
3 A Nearest Resident AT
.90 MILES NW ANNUAL BETA AIR DOSE = 2.18E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 3.27E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+______-___+________-_+________-_+_________-+_________-+-_________+__________+_________-+
PLUME z 2.19E-04 : 2.19E-04 : 2.19E-04 : 2.19E-04 z 2.19E-04 : 2.19E-04 : 2.21E-04 : 4.44E-04 :
-________+______-___+________-_+________-_+________-_+________-_+_________-+_______-__+________-_+
GROUND
- 2.63E-04 : 2.63E-04 : 2.63E-04 : 2.63E-04 : 2.63E-04 : 2.63E-04 : 2.63E-04 : 3.10E-04 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I
ADULT 3.62E-04 1.98E-03 1.22E-02 : 1.85E-05 : 1.99E-05 : 2.82E-03 : 1.01E-07 0.00E+00 :
-________+______-___+_________-+_________-+__________+-_________+__________+_________-+________-_+
TEEN
- 5.97E-04 : 2.44E-03 : 2.03E-02 : 2.81E-05 : 2.99E-05 : 3.80E-03 : 1.90E-07 a 0.00E+00 I
-________+______-___+________-_+_________-+________-_+________-_+_________-+-_________+_________-+
CHILD
- 1.44E-03 : 1.93E-03 : 4.95E-02 : 4.49E-05 : 4.71E-05 : 7.29E-03 : 2.89E-07 : 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT a 6.28E-06 : 3.10E-05 : 1.21E-04 a 4.48E-06 2.90E-06 a 7.59E-05 a 8.27E-09 a 0.00E+00
-________+______-___+________-_+_______-__+________-_+________-_+________-_+________-_+________-_+
TEEN a 5.12E-06 : 1.83E-05 : 1.01E-04 : 3.45E-06 : 2.17E-06 : 5.50E-05 : 7.82E-09 0.00E+00 :
-________+______-___+________-_+________-_+________-_+________-_+________-_+________-_+________-_+
CHILD a 8.84E-06 a 1.05E-05 a 1.91E-04 a 4.03E-06 a 2.50E-06 a 8.30E-05 : 9.19E-09 : 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
I a
a I
ADULT
- 2.71E-05 a 1.12E-04 : 5.81E-04 a 2.15E-05 a 2.10E-05 a 2.11E-03 a 6.99E-08 a 0.00E+00 TEEN
- 4.81E-05 : 1.49E-04 : 1.07E-03 : 3.68E-05 : 3.57E-05 : 3.35E-03 : 1.44E-07 a 0.001+00 s CHILD
- 1.09E-04 : 1.16E-04 : 2.63E-03 : 5.84E-05 : 5.66E-05 : 6.62E-03 : 2.22E-07 : 0.00E+00 :
-________+_____-____+________-_+________-_+_________-+_________-+__________+-_________+_________-+
INFANT : 1.93E-04 : 1.62E-04 : 4.98E-03 : 1.16E-04 : 8.91E-05 : 1.61E-02 : 4.02E-07 : 0.00E+00 :
-________+__________+__________+__________+__________+__________+__________+_---+-__+____-+___-__+
GOATMILK :
ADULT
- 4.08E-05 a 1.95E-04 a 1.21E-03 a 1.14E-05 a 1.52E-05 a 2.54E-03 a 2.10E-07 a 0.00E+00
-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+
TEEN
- 7.29E-05 : 2.66E-04 : 2.22E-03 : 2.01E-05 : 2.69E-05 : 4.01E-03 : 4.33E-07 : 0.00E+00 :
-________+_____-____+_________-+_________-+__________+-_________+__________+________--+________-_+
CHILD
- 1.72E-04 a 2.13E-04 : 5.48E-03 : 3.43E-05 : 4.44E-05 : 7.94E-03 : 6.66E-07 : 0.00E+00 :
-________+______-___+________-_+________-_+_________-+-_________+__________+_________-+________-_+
INFANT : 3.26E-04 : 2.21E-04 : 1.04E-02 : 7.79E-05 : 7.59E-05 : 1.93E-02 : 1.20E-06 : 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL a
ADULT a 1.54E-06 a 4.72E-05 4.16E-05 a 7.34E-07 a 1.07E-06 a 1.50E-04 a 1.97E-04 a 0.00E+00
-________+______-___+_________-+_________-+__________+-_________+__________+-_________+_________-+
TEEN
- 2.16E-06 : 5.17E-05 : 5.91E-05 : 1.00E-06 : 1.47E-06 : 1.88E-04 : 3.38E-04 : 0.00E+00 :
-________+_____-____+________-_+_________-+__________+-_________+__________+-_________+_________-+
CHILD
- 2.84E-06 : 3.90E-05 : 8.12E-05 : 9.72E-07 : 1.37E-06 : 2.17E-04 : 3.00E-04 : 0.00E+00 :
-________+______-___+________-_+________-_+________-_+________-_+________-_+________-_+________-_+
INFANT : 1.88E-06 : 2.33E-05 : 5.36E-05 : 8.69E-07 : 8.96E-07 : 1.99E-04 : 2.78E-04 : 0.00E+00 :
-________+______-___+__________+_________-+________-_+________-_+________-_+________-_+________-_+
TABLE 5. DOSES TO MAXIMUM INDIVIDUAL (MREM), OCTOBER-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 6.OOE-05 MILLRADS ANNUAL GAMMA AIR DOSE = 9.40E-05 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+__________+__________+__________+_________+__________+__________+_---_____-___+________
PLUME
- 6.30E-05 : 6.30E-05 : 6.30E-05 s 6.30E-05 s 6.30E-05 s 6.30E-05 s 6.37E-05 : 1.26E-04 :
_________+_-4________+__________+_________+__________+_________+__________+______--___+_4______--+
GROUND
- 1.07E-05 : 1.07E-05 : 1.07E-05 : 1.07E-05 : 1.07E-05 : 1.07E-05 : 1.07E-05 : 1.26E-05 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGBT ADULT 1.48E-05 8.07E-05 4.98E-04 8.06E-07 8.47E-07 1.17E-04 5.62E-09 0.00E+00
-________+__________+__________+__________+__________+__________+__________+_____--+-+-+-_____+--_
TEEN
- 2.43E-05 : 9.93E-05 : 8.26E-04 : 1.23E-06 : 1.27E-06 : 1.57E-04 : 1.05E-08 : 0.00E+00 :
_________+-_________+______-___+________-_+__________+__________+________--+__________+_______-_+-
CHILD
- 5.88E-05 : 7.86E-05 : 2.01E-03 : 1.96E-06 : 2.01E-06 : 3.01E-04 : 1.60E-08 : 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT s 2.651-07 s 1.29E-06 s 4.91E-06 2.021-07 1.31E-07 3.14E-06 4.58E-10 0.00E+00 :
_________+_-_________+__________+__________+_________+__________+__________+_--4________+________+
TEEN
- 2.15E-07 : 7.58E-07 : 4.13E-06
- 1.56E-07 : 9.80E-08 : 2.27E-06 : 4.33E-10 : 0.00E+00 :
_________+_-_________+__________+__________+_________+__________+__________+_--4________+_________
CHILD
- 3.70E-07 : 4.34E-07 : 7.78E-06 : 1.82E-07 s 1.13E-07 : 3.43E-06 s 5.09E-10 s 0.00E+00 s
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK:
ADULT
- 1.14E-06 4.74E-06 : 2.37B-05 : 9.62E-07
- 9.13E-07 2 8.74E-05 2 3.87E-09 2 0.OOE+00 2 TEEN
- 2.02E-06 : 6.27E-06 4.35E-05 : 1.64E-06
- 1.55E-06
- 1.38E-04 : 8.00E-09 : 0.00E+00 CHILD
- 4.55E-06 : 4.86E-06
- 1.07E-04 : 2.60E-06 : 2.45E-06 : 2.74E-04 : 1.23E-08 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_--+-+-+-+-____-+____-
INFANT : 8.00E-06 : 6.96E-06 : 2.03E-04 : 5.12E-06 : 3.83E-06 : 6.65E-04 : 2.22E-08 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
I ADULT
- 1.68E-06 : 7.95E-06 : 4.92E-05 5.05E-07 6.43E-07 1.05E-04 1.16E-08 : 0.00E+00
________-+__________+__________+__________+__________+__________+__________+_--________+__________
TEEN
- 2.99E-06 : 1.08E-05 : 9.04E-05 : 8.89E-07 : 1.14E-06 : 1.66E-04 : 2.40E-08 : 0.00E+00 :
_________+_-_________+__________+__________+_________+__________+__________+_--________+__________
CHILD
- 7.05E-06 : 8.71E-06 : 2.23E-04 : 1.52E-06 : 1.87E-06 : 3.28E-04 : 3.69E-08 : 0.00E+00 :
_________+_-_________+__________+__________+_________+__________+__________+_--________+____-_____
INFANT : 1.33E-05 : 9.03E-06 : 4.23E-04 : 3.41E-06 : 3.19E-06
- 7.98E-04 : 6.67E-08 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT 1.29E-07 3.64E-06 3.18E-06 7.76E-08 9.83E-08 : 1.23E-05 1.51E-05 : 0.00E+00
_________+_-_________+__________+__________+_________+__________+__________+_--4________+-________
TEEN
- 1.80E-07 : 4.04E-06 : 4.52E-06 : 1.06E-07 : 1.35E-07 : 1.54E-05 : 2.58E-05 s 0.00E+00 s
_________+_-_________+__________+__________+_________+__________+__________+_--4________+_________
CHILD
- 2.35E-07 : 3.45E-06 : 6.21E-06 : 1.03E-07
- 1.26E-07 : 1.77E-05 : 2.30E-05 : 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+_--________+_____-___+
INFANT : 1.57E-07 : 2.19E-06 : 4.10E-06 : 9.23E-08 : 8.22E-08 : 1.63E-05 : 2.13E-05 0.00E+00
_______-_+-_______-__+_________+________-_+_______-__+_______-_+__________+__________+_______---+
TABLE 5.
DOSES TO MAXIMUM INDIVIDUAL (MREM), OCTOBER-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
5 A Nearest Garden AT 1.20 MILES SE ANNUAL BETA AIR DOSE
- 7.42E-05 MILLRADS ANNUAL GAMMA AIR DOSE -
1.09E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_________+______-___+__________-+______-__+__________+-_________+__________+-_________+_________-+
PLUME
- 7.28E-05 : 7.28E-05 : 7.28E-05 : 7.28E-05 : 7.28E-05 : 7.28E-05 : 7.35E-05 : 1.49E-04 :
_________+______-___+_________-+_________-+________-_+________-_+________-_+________-_+________-_+
GROUND
- 1.28E-04 : 1.28E-04 : 1.28E-04 : 1.28E-04 : 1.28E-04 : 1.28E-04 : 1.28E-04 : 1.50E-04 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I
I ADULT 1.76E-04 9.62B-04 : 5.95E-03 8.50E-06 9.34E-06 1.36E-03 3.59E-08 0.00E+00 :
_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+
TEEN
- 2.90E-04 : 1.18E-03 : 9.85E-03 : 1.29E-05 : 1.40E-05 : 1.83E-03 : 6.72E-08 : 0.00E+00 I
__________________+______----9-__+________+_________+_____---+_--__________+______--_-_+__________
CHILD
- 7.01E-04 : 9.38E-04 : 2.40E-02 : 2.07E-05 : 2.22E-05 : 3.51E-03 : 1.02E-07 : 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT I
ADULT 2.97E-06 : 1.48E-05 5.85E-05 2.00E-06 1.29E-06 3.66E-05 2.93E-09 0.00E+00
_________+__________+___-_-_-__+________-_+________-_+________-_+_________-+________-_+________-_+
TEEN
- 2.43E-06 : 8.78E-06 : 4.92E-05 : 1.54E-06 : 9.65E-07 : 2.65E-05 : 2.77E-09 0.OOE+00
_________+-_________+_______-__+________-_+_________-+_________-+__________+_______--_+-_________+
CHILD
- 4.20E-06 : 5.05E-06 : 9.26E-05
- 1.80E-06 : 1.12E-06 : 4.00E-05 : 3.25E-09 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK:
ADULT
- 1.28E-05 5.29E-05 2.82E-04 9.71E-06 9.69E-06 1.02E-03 2.47E-08 0.00E+00
-- _____+_____-____+________-_+________-_+________-_+________-_+_______-__+________-_+________-_+
TEEN
- 2.28E-05 : 7.06E-05 : 5.18E-04 : 1.66E-05
- 1.65E-05 : 1.61E-03
- 5.11E-08 : 0.00E+00
_________+-_________+_______-__+_________-+__________-+____-____+________-_+_______-__+________-_+
CHILD
- 5.18E-05 : 5.53E-05 : 1.28E-03
- 2.64E-05
- 2.63E-05 : 3.19E-03
- 7.85E-08 : 0.00E+00 :
_________+-_________+_______-__+________-_+________-_+_________-+________-_+_______-__+________-_+
INFANT : 9.22E-05
- 7.57E-05 : 2.42E-03
- 5.29E-05 : 4.15E-05 : 7.76E-03
- 1.42E-07 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK ADULT
- 1.96E-05 9.44E-05 5.86E-04 5.20E-06 7.21E-06 1.22E-03 7.42E-08 0.00E+00
_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+
TEEN
- 3.52E-05 : 1.29E-04 : 1.08E-03 : 9.15E-06 : 1.28E-05 : 1.94E-03 : 1.53E-07 0.00E+00 :
_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+
CHILD
- 8.35E-05
- 1.04E-04 : 2.66E-03
- 1.56E-05 : 2.11E-05 : 3.83E-03
- 2.36E-07 0.00E+00 :
_________+-_________+________-_+_________-+__________+-_________+__________+-_________+_________-+
INFANT : 1.58E-04 : 1.07E-04 : 5.04E-03
- 3.59E-05 : 3.61E-05 : 9.31E-03
- 4.26E-07
- 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT
- 6.11E-07 1.88E-05 : 1.64E-05 2.97E-07 4.43E-07 6.25E-05 7.85E-05 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN
- 8.55E-07 : 2.14E-05 : 2.33E-05 : 4.07E-07 : 6.08E-07 : 7.84E-05 : 1.34E-04 0.00E+00 :
CHILD
- 1.12E-06 : 2.40E-05 : 3.21E-05 : 3.94E-07 : 5.69E-07 : 9.07E-05 : 1.19E-04 0.00E+00 :
_________+-_________+_______-__+_______-__+________-_+________-_+________-_+________-_+________-_+
INFANT : 7.46E-07 : 1.68E-05 : 2.12E-05 : 3.53E-07 : 3.72E-07 : 8.31E-05 : 1.11E-04 : 0.00E+00
_______-_+-_________+______-___+________-_+_________-+_________-+_________-+_________-+________-__
TABLE 6.
DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-DECEMBER 2004 SPECIAL LOCATION NO.
1 A Site Boundary AT
.69 MILES NNW ANNUAL BETA AIR DOSE. 2.86E-04 MILLRADS ANNUAL GAMMA AIR DOSE a 4.01E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+__________+__________+__________+__________+__________+__________+_---________-+____-__+
PLUME
- 2.68E-04 : 2.68E-04
- 2.68E-04 : 2.68E-04
- 2.68E-04 : 2.68E-04 : 2.71E-04 : 5.54E-04
________-+__________+__________+__________+__________+__________+__________+_---________-+____-__+
GROUND
- 9.22E-04
- 9.22E-04 : 9.22E-04 : 9.22E-04 : 9.22E-04 : 9.22E-04 : 9.22E-04 : 1.08E-03
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I
I ADULT
- 1.08E-03 : 5.86E-03 : 3.61E-02 : 7.19E-05 : 9.36E-05 : 1.56E-02 : 1.22E-07 : 0.OOE+00
________-+__________+__________+__________+__________+__________+__________+_---________-+____-__+
TEEN
- 1.78E-03
- 7.21E-03
- 5.99E-02 : 1.09E-04 : 1.41E-04 : 2.10E-02 : 2.29E-07 : 0.OOE+00
________-+__________+__________+__________+__________+__________+__________+_--________+____-____+
CHILD
- 4.29E-03
- 5.71E-03 : 1.46E-01 : 1.77E-04 : 2.25E-04 : 4.03E-02 : 3.48E-07 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT I
ADULT 1.84E-05 9.36E-05 : 3.55E-04 1.17E-05 8.01E-06 4.20E-04 9.94E-09 O.OOE+00
________-+__________+__________+__________+__________+__________+__________+_---________-+____-__+
TEEN
- 1.50E-05 : 5.52E-05
- 2.98E-04 : 9.03E-06 : 6.07E-06 : 3.04E-04
- 9.41E-09 0.OOE+00
________-+__________+__________+__________+__________+__________+__________+_---________-+____-__+
CHILD
- 2.59E-05 : 3.17E-05
- 5.63E-04 : 1.06E-05 : 7.13E-06
- 4.59E-04
- 1.11E-08 : O.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
s z
ADULT
- 8.50E-05 : 3.16E-04 : 1.72E-03 : 7.07E-05 s 8.48E-05 s 1.17E-02 8.39E-08 0.OOE+00
+ __________+__________+__________+__________+__________+__________+___--+-
+
+
+____
_ +
TEEN
- 1.51E-04
- 4.23E-04
- 3.16E-03 : 1.22E-04 : 1.47E-04 : 1.85E-02 : 1.73E-07 : O.OOE+00 :
_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+_______-__+
CHILD
- 3.37E-04 : 3.33E-04
- 7.80E-03
- 2.OOE-04
- 2.38E-04 : 3.67E-02
- 2.66E-07 0.OOE+00
_______-_+-_________+______-___+________-_+________-_+__________+__________+__________+_________-+
INFANT : 6.07E-04 : 4.42E-04
- 1.48E-02 : 4.26E-04
- 3.93E-04 : 8.92E-02 : 4.82E-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 1.29E-04 5.78E-04 3.57E-03 4.98E-05 7.80E-05 1.41E-02 2.52E-07 0.OOE+00
________-+__________+__________+__________+__________+__________+__________+_--+-+-+-__+_+_+-___+
TEEN
- 2.31E-04 : 7.89E-04
- 6.57E-03
- 8.80E-05 : 1.39E-04 : 2.22E-02
- 5.20E-07 : 0.OOE+00
________-+__________+__________+__________+__________+__________+__________+_--+-____+_+___+-___+
CHILD
- 5.41E-04 : 6.34E-04 : 1.62E-02 : 1.52E-04 : 2.30E-04 : 4.40E-02 : 7.99E-07 : 0.OOE+00
________-+__________+__________+__________+__________+__________+__________+_---________-+____-__+
INFANT : 1.02E-03
- 6.53E-04 : 3.07E-02 : 3.60E-04 : 3.97E-04
- 1.07E-01 : 1.45E-06 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT 5.49E-06 1.50E-04 1.28E-04 3.96E-06 6.35E-06 9.18E-04 6.31E-04 0.OOE+00
________-+__________+__________+__________+__________+__________+__________+_--+-+-+-__+_+_+-___+
TEEN
- 7.62E-06 : 1.94E-04 : 1.83E-04 : 5.43E-06 : 8.74E-06 : 1.15E-03 : 1.08E-03 : 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--____+___+____-____+
CHILD
- 9.81E-06 : 4.30E-04
- 2.51E-04 : 5.30E-06 : 8.19E-06 : 1.34E-03 : 9.57E-04 0.OOE+00
________-+__________+__________+__________+__________+__________+__________+_--________+____-____+
INFANT : 6.57E-06 : 3.45E-04 : 1.66E-04 : 4.83E-06
- 5.38E-06 : 1.23E-03 : 8.89E-04 0.OOE+00
________-+__________+__________+__________+__________+__________+__________+_---+-______+-+___-__+
TABLE 6. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
2 A Site Boundary AT
.67 MILES N
ANNUAL BETA AIR DOSE -
3.24E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 4.39E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_________+______-___+________-_+________-_+_________-+________-_+________-_+________-_+________-_+
PLUME
- 2.94E-04 : 2.94E-04 : 2.94E-04 : 2.94E-04 s 2.94E-04
- 2.94E-04 : 2.97E-04 : 6.14E-04
_________+_____-____+________-_+________-_+________-_+________-_+________-_+_________-+_________-+
GROUND
- 1.10E-03 : 1.10E-03 : 1.10E-03 : 1.10E-03 : 1.10E-03 s 1.10E-03 : 1.10E-03 : 1.30E-03
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET IsI I
ADULT 1.29E-03 s 7.02E-03 4.32E-02 8.62E-05 s 1.12E-04 1.87E-02 s 1.52E-07 0.00E+00
________-+__________+__________+__________+_________+__________+__________+_--4____4___-___._4__+
TEEN s 2.13E-03 s 8.63E-03 s 7.16E-02 s 1.31E-04 s 1.69E-04 s 2.52E-02 s 2.85E-07 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---________+-+___-__+
CHILD s 5.14E-03 s 6.83E-03 s 1.75E-01 s 2.13E-04 s 2.70E-04 s 4.82E-02 s 4.33E-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT s
s s
ADULT 2.20E-05 1.12E-04 4.25E-04 1.40E-05 9.64E-06 5.02E-04 1.24E-08 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---+-+-+-+-+-+___-__+
TEEN s 1.80E-05 s 6.61E-05 s 3.57E-04 s 1.09E-05 s 7.30E-06 s 3.64E-04 s 1.17E-08 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+________+-________
CHILD
- 3.11E-05 : 3.79E-05 s 6.73E-04 : 1.28E-05 s 8.57E-06 s 5.49E-04 : 1.38E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK s s
ADULT s 1.02E-04 s 3.79E-04 : 2.06E-03 s 8.49E-05 s 1.02E-04 s 1.40E-02 s 1.04E-07 s 0.OOE+00 s
_---+----__--+-_------+----
+___
_+_-
________+__________+
TEEN 1.80E-04 5.07E-04 s 3.78E-03 1.47E-04 s 1.76E-04 s 2.22E-02 s 2.16E-07 s 0.00E+00
_________+ ______
___+__
+_____
____+
__+___
___+_-
________+__________+
CHILD s 4.03E-04 s 3.99E-04 s 9.33E-03 s 2.40E-04 s 2.86E-04 s 4.39E-02 s 3.31E-07 0.OOE+00
_________+ ______
___+__
+_____
____+
__+___
___+_-
________+__________+
INFANT s 7.27E-04 s 5.31E-04 s 1.77E-02 s 5.12E-04 s 4.70E-04 s 1.07E-01 s 6.OOE-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK s
s s
s ADULT s 1.55E-04 6.92E-04 4.27E-03 5.97E-05 9.34E-05 1.68E-02 3.13E-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+_--________+__________
TEEN
- 2.77E-04 : 9.45E-04 : 7.86E-03 : 1.06E-04 s 1.66E-04 : 2.66E-02 : 6.46E-07 s 0.OOE+00 s
_________+_-_________+__________+__________+_________+__________+__________+_--________+__________
CHILD s 6.48E-04 s 7.59E-04 : 1.94E-02 s 1.82E-04 s 2.75E-04 s 5.27E-02 : 9.94E-07 s 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--+________+_________
INFANT s 1.23E-03 s 7.81E-04 s 3.68E-02 s 4.32E-04 s 4.75E-04 s 1.28E-01 s 1.80E-06 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL s
s s
s s
ADULT 7.43E-06 2.04E-04 1.75E-04 5.29E-06 8.52E-06 1.23E-03 8.58E-04 0.OOE+00
_________+__________+__________+__________+__________+__________+__________-+_-________+_-____-___
TEEN
- 1.03E-05 : 2.63E-04 : 2.48E-04 s 7.26E-06 : 1.17E-05 : 1.55E-03 : 1.47E-03 : 0.OOE+00
_________+__________+_____--_--___________+_________-_+__________+___--____+________-_+________-_+
CHILD s 1.33E-05 s 5.84E-04 s 3.41E-04 : 7.08E-06 s 1.10E-05 s 1.80E-03 s 1.30E-03 s 0.OOE+00
_________+__________+__________+-_-_--______+________+__________+__________+__________+__-__--____
INFANT s 8.88E-06 s 4.68E-04 s 2.26E-04 s 6.45E-06 s 7.22E-06 s 1.65E-03 s 1.21E-03 0.OOE+00
-_______+-_________+______-___+________-_+________-_+________-_+________-_+________-_+________-__
TABLE 6. DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
3 A Nearest Resident AT
.90 MILES NW ANNUAL BETA AIR DOSE -
2.94E-04 MILLRADS ANNUAL GAMMA AIR DOSE = 4.63E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
+ __________+__________+__________+__________+__________+__________+___-
+__
+
PLUME s 3.10E-04 s 3.10E-04 s 3.10E-04 : 3.10E-04 s 3.10E-04 s 3.10E-04 s 3.13E-04 6.16E-04
________-+__________+__________+__________+_________+__________+__________+_--_______.+____-____+
GROUND s 3.59E-04 s 3.59E-04 s 3.59E-04 : 3.59E-04 : 3.59E-04 s 3.59E-04 s 3.59E-04 s 4.22E-04
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I
I ADULT s 4.23E-04 s 2.29E-03 1.41E-02 3.OOE-05 3.76E-05 s 6.07E-03 s 1.10E-07 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_----4_______________+
TEEN s 6.96E-04 s 2.82E-03 s 2.34E-02 s 4.55E-05 s 5.67E-05 s 8.18E-03 s 2.05E-07 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
CHILD s 1.68E-03 s 2.23E-03 s 5.70E-02 s 7.40E-05 s 9.02E-05 s 1.57E-02 s 3.13E-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT s
s s
s ADULT 7.53E-06 3.75E-05 1.39E-04 5.37E-06 3.66E-06 1.63E-04 8.92E-09 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TEEN s 6.13E-06 s 2.21E-05 s 1.17E-04 s 4.15E-06 s 2.76E-06 s 1.18E-04 s 8.44E-09 0.OOE+00 CHILD
- 1.05E-05 : 1.26E-05 : 2.20E-04 s 4.88E-06 s 3.23E-06 s 1.79E-04 s 9.92E-09 s 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK s I
I I
ADULT
- 3.48E-05 s 1.31E-04 s 6.73E-04 s 3.09E-05 s 3.52E-05 : 4.56E-03 : 7.53E-08 s 0.00E+00 s
________-+__________+__________+__________+_________+__________+__________+_--+-+-+-___+_________
TEEN s 6.13E-05 s 1.74E-04 s 1.24E-03 s 5.33E-05 s 6.08E-05 s 7.21E-03 s 1.56E-07 0.OOE+00
_________+_-_________+__________+__________+_________+__________+__________+_--________+_________+
CHILD s 1.36E-04 s 1.36E-04 s 3.05E-03 s 8.65E-05 s 9.79E-05 s 1.43E-02 s 2.39E-07 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+-+-4.-+-__-+__-__+
INFANT s 2.43E-04 s 1.87E-04 s 5.77E-03 s 1.81E-04 s 1.60E-04 s 3.47E-02 s 4.33E-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK s s
s s
ADULT s 5.13E-05 2.26E-04 1.40E-03 2.09E-05 3.10E-05 5.47E-03 2.26E-07 0.OOE+00 TEEN
- 9.13E-05 s 3.09E-04 s 2.57E-03 s 3.68E-05 s 5.50E-05 s 8.66E-03 s 4.67E-07 : 0.OOE+00 CHILD
- 2.12E-04 : 2.48E-04 : 6.34E-03 s 6.34E-05 s 9.11E-05 s 1.71E-02 s 7.17E-07 s 0.00E+00
_________+_-_________+__________+__________+_________+__________+__________+_--________+____-____+
INFANT s 4.01E-04 s 2.57E-04 s 1.20E-02 s 1.49E-04 s 1.57E-04 s 4.16E-02 s 1.30E-06 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL s
s s
s ADULT 1.73E-06 4.56E-05 3.87E-05 1.34E-06 2.01E-06 2.79E-04 1.90E-04 0.OOE+00 TEEN s 2.40E-06 s 5.91E-05 s 5.50E-05 s 1.83E-06 s 2.77E-06 s 3.51E-04 s 3.25E-04 0.OOE+00 CHILD
- 3.08E-06 : 1.33E-04 : 7.56E-05 : 1.79E-06 s 2.60E-06 s 4.07E-04 s 2.88E-04 s 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---_________________+
INFANT s 2.07E-06 s 1.07E-04 s 5.00E-05 s 1.63E-06 s 1.70E-06 s 3.73E-04 s 2.68E-04 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--________+_________+
TABLE 6.
DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
4 A
Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 1.43E-04 MILLRADS ANNUAL GAMMA AIR DOSE -
2.33E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+__________+__________+__________+__________+__________+__________+_---________--+______+
PLUME
- 1.56E-04
- 1.56E-04 : 1.56E-04 : 1.56E-04 : 1.56E-04 : 1.56E-04
- 1.57E-04 : 3.06E-04
-________+__________+__________+__________+__________+__________+__________+_--________+____-____+
GROUND
- 2.12E-05 : 2.12E-05 : 2.12E-05 : 2.12E-05 : 2.12E-05 : 2.12E-05
- 2.12E-05
- 2.49E-05
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT 2.52E-05 1.36E-04 8.39E-04 1.87E-06 2.28E-06 3.58E-04 9.56E-09 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_---+-______-+____-__+
TEEN
- 4.14E-05 : 1.68E-04 : 1.39E-03
- 2.85E-06 : 3.43E-06 : 4.82E-04
- 1.79E-08 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-+-_________
CHILD
- 9.98E-05 : 1.33E-04 : 3.39E-03
- 4.61E-06 : 5.45E-06 : 9.25E-04
- 2.72E-08 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT
- 4.65E-07 : 2.28E-06 : 8.27E-06 : 3.59E-07 2.44E-07 : 9.63E-06 7.78E-10 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_--+-+-_____+________+
TEEN
- 3.77E-07 : 1.34E-06 s 6.95E-06
- 2.77E-07 : 1.83E-07 : 6.98E-06
- 7.36E-10
- 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_--________+_________+
CHILD
- 6.45E-07 s 7.61E-07 : 1.31E-05 : 3.25E-07 : 2.14E-07 : 1.05E-05
- 8.65E-10
- 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
ADULT
- 2.14E-06 8.11E-06 4.01E-05 2.00E-06 2.18E-06 2.69E-04 6.56E-09 0.OOE+00 00
+----+----------+--------------------+---------------------
TEEN
- 3.76E-06 : 1.07E-05 : 7.35E-05 : 3.43E-06 : 3.76E-06 4.25E-04 : 1.36E-08 : 0.00E+00
-________+__________+__________+__________+__________+__________+__________+_--________+____-_____
CHILD
- 8.32E-06 : 8.32E-06 : 1.81E-04 : 5.55E-06 : 6.04E-06 : 8.41E-04 : 2.08E-08 : 0.00E+00
-_________+__________+__________+_________+__________+__________+__________+_--+-_______+_________
INFANT : 1.47E-05 : 1.18E-05 : 3.43E-04 : 1.15E-05 : 9.78E-06 : 2.04E-03 : 3.77E-08
- 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK:
ADULT
- 3.09E-06 : 1.35E-05 s 8.30E-05 s 1.30E-06 1.86E-06 3.22E-04 1.97E-08 : 0.00E+00
-_________+__________+__________+_________+__________+__________+__________+_--________+__________
TEEN
- 5.46E-06 : 1.84E-05 : 1.52E-04 : 2.30E-06 : 3.29E-06 : 5.10E-04 : 4.07E-08
- 0.00E+00
-_________+__________+__________+_________+__________+__________+__________+_--________+____+_____
CHILD
- 1.27E-05 : 1.48E-05 : 3.77E-04 : 3.95E-06 : 5.45E-06 : 1.01E-03 : 6.25E-08 : 0.OOE+00
-_________+__________+__________+_________+__________+__________+__________+_---_______+__________
INFANT : 2.39E-05 : 1.53E-05 : 7.14E-04 : 9.17E-06 : 9.37E-06 : 2.45E-03 : 1.13E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT 2.35E-07 5.23E-06 : 4.37E-06 2.23E-07 : 2.72E-07 : 3.21E-05 : 2.12E-05 : 0.00E+00
-________+__________+__________+__________+__________+__________+__________+_---________4.-+__-__+
TEEN
- 3.24E-07
- 6.39E-06 : 6.22E-06 : 3.06E-07 : 3.74E-07 : 4.02E-05 : 3.61E-05 : 0.00E+00
-_________+__________+__________+_________+__________+__________+__________+_--4.-4.-______-+-+__-
CHILD
- 4.13E-07
- 1.08E-05 : 8.54E-06 : 2.99E-07
- 3.51E-07 : 4.66E-05 : 3.21E-05 : 0.00E+00
-________+__________+__________+__________+__________+__________+__________+_--+-+-+-+-__________+
INFANT : 2.80E-07
- 8.35E-06 : 5.66E-06 : 2.72E-07 : 2.30E-07 : 4.27E-05 : 2.98E-05 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+-+-_____+_________
TABLE 6.
DOSES TO MAXIMUM INDIVIDUAL (MREM), JULY-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
5 A Nearest Garden AT 1.20 MILES SE ANNUAL BETA AIR DOSE
- 6.79E-05 MILLRADS ANNUAL GAMMA AIR DOSE
- 1.01E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+__________+--4--______+__________+__________+__________+__________+__-----_____+__--__+
PLUME
- 6.73E-05 : 6.73E-05 : 6.73E-05 : 6.73E-05 : 6.73E-05 : 6.73E-05 : 6.80E-05 : 1.36E-04
-________+__________+-
+___
_+
__-----+
-___+_--____
GROUND
- 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.19E-04 : 1.40E-04
+-
+-------------------+-
+
+
+--
VEGET I
ADULT 1.40E-04 7.60E-04 : 4.68E-03 9.60E-06 1.23E-05 2.02E-03 2.51E-08 0.OOE+00
-________+__________+-
+___
_+
__----+
-+
-___+_--__+
TEEN
- 2.30E-04 : 9.34E-04 : 7.75E-03 : 1.46E-05 : 1.85E-05 : 2.72E-03 : 4.70E-08 : 0.OOE+00
________+__--______+_--_--______+__________+__________+__________+__________+__-----_____+__--__+
CHILD
- 5.56E-04 : 7.40E-04 : 1.89E-02 : 2.37E-05 : 2.95E-05 : 5.21E-03 : 7.15E-08 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT 2.43E-06 1.23E-05 4.60E-05 1.63E-06 1.12E-06 :5.43E-05 2.04E-09 0.OOE+00
_________+______
___+__
+_____
____+
__+___
___+_---+
+____- _
+
TEEN
- 1.98E-06 : 7.22E-06 : 3.87E-05 : 1.26E-06 : 8.45E-07 : 3.93E-05 : 1.93E-09 : 0.00E+00
_________+______
___+__
+_____
____+
__+___
___+_--+
-________+-
+__-
+
CHILD
- 3.42E-06 : 4.14E-06 : 7.29E-05 : 1.49E-06 : 9.90E-07 : 5.94E-05 : 2.27E-09 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
I ADULT
- 1.12E-05 4.20E-05 2.23E-04 : 9.65E-06 1.13E-05 1.51E-03 1.72E-08 O.OOE+00
_________+__________+__________+__________+__________+__________+__________+---
+_+__+_++____-
+
TEEN
- 1.99E-05 : 5.61E-05 : 4.10E-04 : 1.67E-05 : 1.96E-05 : 2.40E-03 : 3.56E-08 : 0.00E+00 :
_________+ ______
___+__
+_____
____+
__+___
___+_---________+-
+___-_
+
CHILD
- 4.43E-05 : 4.40E-05 : 1.01E-03 : 2.71E-05 : 3.16E-05 : 4.74E-03 : 5.47E-08 : 0.OOE+00
_________+______
___+__
+_____
____+
__+___
___+_--+-
+
+
+
+-
+
+__-
+
INFANT : 7.95E-05 : 5.95E-05 : 1.91E-03 : 5.75E-05 : 5.18E-05 : 1.15E-02 : 9.89E-08 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 1.69E-05 7.49E-05 4.63E-04 6.66E-06 1.02E-05 1.82E-03 5.16E-08 :0.OOE+00:
_________+ ______
___+__
+_____
____+
__+___
___+_--+
-______+_+_+-_
_+
TEEN
- 3.01E-05 : 1.02E-04 : 8.51E-04 : 1.18E-05 : 1.81E-05 : 2.88E-03 : 1.07E-07 0.OOE+00
_________+_________+________+_________+________+__________________+_--+-
+
+
+
+
+
+__-
_+
CHILD
- 7.02E-05 : 8.22E-05 : 2.10E-03 : 2.03E-05 : 3.OOE-05 : 5.69E-03 : 1.64E-07 0.OOE+00
_________+______
___+__
+_____
____+
__+___
___+_--+-
+
+
+
+
+
+__-
+
INFANT : 1.33E-04 : 8.48E-05 : 3.98E-03 : 4.79E-05 : 5.17E-05 : 1.38E-02 : 2.97E-07 : 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT
- 8.66E-07 : 2.34E-05 2.OOE-05 : 6.36E-07 : 1.01E-06 : 1.44E-04 : 9.82E-05 0.OOE+00
_________+______
___+__
+_____
____+
__+___
___+_-
-________+____-
+
TEEN
- 1.20E-06 : 3.02E-05 : 2.84E-05 : 8.73E-07 : 1.39E-06 : 1.82E-04 : 1.68E-04 0.OOE+00
_________+_________+________+_________+________+__________________+_--+-
+
+
+
+
+
+__-
_+
CHILD
- 1.54E-06 : 6.73E-05 : 3.91E-05 : 8.52E-07 : 1.30E-06 : 2.11E-04 : 1.49E-04 0.OOE+00
_________+______
___+__
+_____
____+
__+___
___+_--+-
+
+
+
+
+
+__-
+
INFANT : 1.03E-06 : 5.40E-05 : 2.58E-05 : 7.77E-07 : 8.54E-07 : 1.93E-04 : 1.38E-04 : 0.OOE+00
_________+ ______
___+__
+_____
____+
__+___
___+_--+__+_+_+_+_______
+
TABLE 7. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-DECEMBER 2004 SPECIAL LOCATION NO.
1 A Site Boundary AT
.69 MILES NNW ANNUAL BETA AIR DOSE -
4.661-04 MILLRADS ANNUAL GAMMA AIR DOSE = 7.25E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+______-___+_________-+_________-+_________-+-_________+__________+_________-+_______-__+
PLUME
- 4.86E-04 : 4.86E-04 : 4.86E-04 : 4.86E-04 : 4.86E-04 : 4.86E-04 : 4.90E-04 : 9.67E-04
-________+______-_-_+_________-+__________+-_________+_________-+________-_+__________+_________-+
GROUND
- 8.21E-04 : 8.21E-04 : 8.21E-04 : 8.21E-04 : 8.21E-04 : 8.21E-04 : 8.21E-04 : 9.66E-04
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET I
ADULT 9.83E-04 5.21E-03 3.21E-02 1.07E-04 : 1.57E-04 2.79E-02 1.50E-07 0.OOE+00
-________+_____-____+_________-+_________-+_______-__+________-_+________-_+_______-__+________-_+
TEEN
- 1.61E-03 : 6.40E-03 : 5.31E-02 : 1.62E-04 : 2.37E-04 : 3.75E-02 : 2.80E-07 : 0.00E+00
-________+_____-____+_________-+_________-+________-_+________-_+________-_+________-_+________-_+
CHILD
- 3.87E-03 : 5.07E-03 : 1.30E-01 : 2.68E-04 : 3.80E-04 : 7.19E-02 : 4.26E-07 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT
- 1.70E-05 8.34E-05 3.16E-04 1.15E-05 9.07E-06 7.50E-04 1.21E-08 0.OOE+00
-________+______-___+__________+_________-+________-_+________-_+________-_+________-_+________-_+
TEEN
- 1.38E-05 : 4.92E-05 : 2.65E-04 : 8.95E-06 : 6.99E-06 : 5.43E-04 : 1.15E-08 : 0.00E+00
-________+______-___+__________+_________-+________-_+________-_+________-_+________-_+________-_+
CHILD
- 2.37E-05 : 2.82E-05 : 5.00E-04 : 1.07E-05 : 8.36E-06 : 8.20E-04 : 1.35E-08 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
I I
'TI ADULT
- 9.39E-05 : 2.89E-04 : 1.55E-03 : 9.52E-05 : 1.31E-04 : 2.09E-02 1.02E-07 0.OOE+00 TEEN 1.64E-04 3.87E-04 2.84E-03 1.66E-04 : 2.30E-04 3.31E-02 : 2.11E-07 : 0.00E+00 CHILD
- 3.55E-04 : 3.05E-04 : 7.01E-03 : 2.78E-04 : 3.76E-04 : 6.54E-02 : 3.25E-07 : 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_---________-+____-__+
INFANT : 6.45E-04 : 4.01E-04 : 1.33E-02 : 6.25E-04 : 6.35E-04 : 1.59E-01 : 5.87E-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 1.37E-04 5.23E-04 3.19E-03 8.38E-05 1.36E-04 2.51E-02 3.06E-07 0.OOE+00
-________+__________+__________+__________+__________+__________+__________+_--+-+-__+____-+__-__+
TEEN
- 2.42E-04 : 7.14E-04 : 5.87E-03 : 1.481-04 : 2.42E-04 : 3.97E-02 : 6.33E-07 : 0.00E+00
-________+__________+__________+__________+__________+__________+__________+_---________+-+___-__+
CHILD
- 5.481-04 : 5.74E-04 : 1.45E-02 : 2.57E-04 : 4.02E-04 : 7.85E-02 : 9.73E-07 : 0.00E+00
-________+__________+__________+__________+__________+__________+__________+_---+-+-+-___-+___-__+
INFANT : 1.04E-03 : 5.90E-04 : 2.75E-02 : 6.19E-04 : 6.97E-04 : 1.91E-01 : 1.76E-06 : 0.00E+00
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT
- 6.71E-06 1.36E-04 1.22E-04 6.98E-06 1.16E-05 1.74E-03 5.67E-04 0.00E+00
+------------------------------
+
+-
-+
+
+-
+-
-+
TEEN
- 9.19E-06 : 1.47E-04 : 1.73E-04 : 9.60E-06 : 1.59E-05 : 2.19E-03 : 9.68E-04 : 0.00E+00
-+-----------------------------------------+-
+
+-
-+
+
+-
+-
-+
CHILD
- 1.14E-05 : 9.32E-05 : 2.38E-04 : 9.40E-06 : 1.49E-05 : 2.52E-03 : 8.59E-04 : 0.00E+00 INFANT : 7.74E-06 : 4.99E-05 : 1.58E-04 : 8.65E-06 : 9.83E-06 : 2.31E-03 : 7.95E-04 0.00E+00
-________+______-___+_________-+__________+_________-+________-_+________-_+________-_+________-_+
TABLE 7.
DOSES TO MAXIMUM INDIVIDUAL (MREM),
JANUARY-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
2 A Site Boundary AT
.67 MILES N
ANNUAL BETA AIR DOSE = 8.15E-04 MILLRADS ANNUAL GAMMA AIR DOSE -
1.OOE-03 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
_________+__________+__________+__________+__________+__________+__________+--_________+-________+
PLUME s 6.72E-04
- 6.72E-04 : 6.72E-04 : 6.72E-04 : 6.72E-04
- 6.72E-04
- 6.80E-04 : 1.50E-03
_________+__________+__________+__________+__________+__________+__________+--_________+-________+
GROUND
- 1.09E-03
- 1.09E-03
- 1.09E-03 : 1.09E-03 : 1.09E-03
- 1.09E-03
- 1.09E-03
- 1.28E-03
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET ADULT 1.30E-03 6.90E-03 4.25E-02 1.44E-04 2.12E-04 3.76E-02 2.20E-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--+_++__+__++-_______+
TEEN
- 2.14E-03 : 8.48E-03 : 7.03E-02 : 2.19E-04 : 3.20E-04 : 5.06E-02 : 4.12E-07 : 0.OOE+00 s
_________+__________+__________+__________+__________+__________+__________+--+__+__+___+-_______+
CHILD : 5.12E-03 : 6.72E-03 : 1.72E-01 : 3.61E-04 : 5.13E-04 : 9.70E-02 : 6.26E-07 : 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT
- 2.26E-05 : 1.11E-04 4.18E-04 1.55E-05 : 1.22E-05 1.01E-03 1.78E-08 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+---_________--+___-__+
TEEN
- 1.83E-05 : 6.52E-05 : 3.51E-04 : 1.20E-05 : 9.42E-06 : 7.32B-04 : 1.69E-08 : O.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+--_________+_____+___+
CHILD
- 3.15E-05 : 3.74E-05 : 6.63E-04 : 1.44E-05 : 1.13E-05 : 1.10E-03 : 1.98E-08 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK :
O ADULT
- 1.26E-04 3.85E-04 2.05E-03 1.29E-04 1.77E-04 2.82E-02 1.50E-07 :0.OOE+00
_+_____----_+__________+-_________+_________-+__________+__________+_______---+________+--
TEEN
- 2.20E-04 : 5.16E-04 : 3.77E-03 : 2.25E-04 : 3.11E-04 : 4.47E-02 : 3.11E-07 : 0.00E+00 :
_________+__________+__________+__________+__________+__________+__________+--+_________+_________
CHILD
- 4.74E-04 : 4.06E-04 : 9.29E-03 : 3.76E-04 : 5.09E-04 : 8.84E-02 : 4.77E-07 : 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+---________+___+_+____
INFANT : 8.62E-04 : 5.36E-04 : 1.76E-02 : 8.46E-04 : 8.60E-04 : 2.15E-01 : 8.64E-07 : 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT 1.83E-04 6.94E-04 4.23E-03 1.14E-04 1.85E-04 3.39E-02 4.51E-07 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+---+-_______-+-+__-__+
TEEN
- 3.23E-04 : 9.47E-04 : 7.78E-03 : 2.01E-04 : 3.29E-04 : 5.36E-02 : 9.31E-07 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+--+__++_____+-________
CHILD
- 7.30E-04 : 7.61E-04 : 1.92E-02 : 3.49E-04 : 5.45E-04 : 1.06E-01 : 1.43E-06 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+--+-______+_+_________
INFANT : 1.38E-03 : 7.83E-04 : 3.64E-02 : 8.40E-04 : 9.45E-04 : 2.58E-01 : 2.59E-06 : 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT
- 8.79E-06 : 1.84E-04 : 1.55E-04 : 9.65E-06 1.61E-05 2.35E-03 7.65E-04 0.OOE+00
_________+__________+__________+_________+__________+__________+__________+_--________+___+___+_+
TEEN
- 1.20E-05 : 2.64E-04 : 2.21E-04 : 1.33E-05 : 2.22E-05 : 2.95E-03 : 1.31E-03 0.OOE+00
_________+__________+__________+__________+__________+__________+__________+--+____+___++________+
CHILD
- 1.49E-05 : 8.OOE-04 : 3.03E-04 : 1.30E-05 : 2.08E-05 : 3.43E-03 : 1.16E-03 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+--+-___+___++_________
INFANT : 1.01E-05 : 6.65E-04 : 2.01E-04 : 1.20E-05 : 1.37E-05 : 3.15E-03 : 1.08E-03 : 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+--_________+_________+
TABLE 7.
DOSES TO MAXIMUM INDIVIDUAL (MREM),
JANUARY-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
3 A Nearest Resident AT
.90 MILES NW ANNUAL BETA AIR DOSE 5.71E-04 MILLRADS ANNUAL GAMMA AIR DOSE a 8.70E-04 MILLRADS PATHWAY T.BODY 01-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+__________+__________+__________+_________+__________+__________+_--________+____-_____
PLUME
- 5.83E-04 : 5.83E-04 : 5.83E-04 : 5.83E-04 : 5.83E-04 : 5.83E-04 : 5.89E-04 : 1.18E-03 :
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
GROUND
- 3.04E-04 : 3.04E-04 : 3.04E-04 : 3.04E-04 : 3.04E-04 : 3.04E-04 : 3.04E-04 : 3.57E-04 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET s
s s
s ADULT s 3.64E-04 1.93E-03 1.18E-02 4.10E-05 5.90E-05 1.04E-02 1.03E-07 :0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--+-+-______-+___-__+
TEEN s 5.96E-04 : 2.37E-03 : 1.96E-02 : 6.20E-05 s 8.91E-05 s 1.40E-02 s 1.94E-07 : 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
CHILD
- 1.43E-03 : 1.88E-03 : 4.79E-02 : 1.02E-04 : 1.43E-04 : 2.67E-02 : 2.94E-07 : 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT I
ADULT 6.46E-06 3.13E-05 1.17E-04 4.70E-06 3.65E-06 2.78E-04 8.39E-09 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---________-+___-___+
TEEN
- 5.25E-06 : 1.84E-05 : 9.81E-05 : 3.65B-06 : 2.81E-06 : 2.02E-04 : 7.94E-09 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_---+-______-+____-__+
CHILD
- 8.97E-06 : 1.06E-05 : 1.85E-04 : 4.36E-06 : 3.35E-06 : 3.04E-04 : 9.33E-09 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK:
ADULT : 3.57E-05 : 1.11E-04 5.73E-04 3.74E-05 4.99E-05 7.78E-03 7.06E-08 0.OOE+00
-_________+
__________+__________+__________+__________+__________+__________+-----___+__-
+
TEEN
- 6.23E-05 : 1.48E-04 : 1.05E-03 : 6.51E-05 : 8.76E-05 : 1.23E-02 : 1.46E-07 : 0.OOE+00
+
_ +
+
+
_+0 CHILD s 1.34E-04 : 1.16E-04 : 2.59E-03 : 1.08E-04 : 1.43E-04 : 2.44E-02 : 2.24E-07 : 0.OOE+00 :
INFANT : 2.42E-04 : 1.56E-04 : 4.92E-03 : 2.42E-04 : 2.41E-04 s 5.92E-02 s 4.06E-07 : 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 5.14E-05 1.94E-04 1.18E-03 3.23E-05 5.13E-05 9.34E-03 2.12E-07 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---+-______-+____-__+
TEEN
- 9.04E-05 : 2.65E-04 : 2.17E-03 : 5.72E-05 : 9.13E-05 : 1.48E-02 : 4.38E-07 : 0.00E+00 :
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
CHILD
- 2.04E-04 : 2.12E-04 : 5.36E-03 : 9.92E-05 : 1.51E-04 : 2.93E-02 : 6.73E-07 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_---____+____-+___-__+
INFANT : 3.85E-04 : 2.19E-04 : 1.02E-02 : 2.37E-04 : 2.62E-04 : 7.11E-02 : 1.22E-06 : 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT 2.21E-06 4.56E-05 3.80E-05 2.47E-06 3.97E-06 : 5.64E-04 1.88E-04 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_--________+____-____+
TEEN
- 3.02E-06 : 6.57E-05 : 5.40E-05 : 3.39E-06 : 5.47E-06 : 7.10E-04 : 3.21E-04 0.OOE+00 :
_________+_-_________+__________+__________+_________+__________+__________+_---+-______+-+___-__+
CHILD
- 3.75E-06 : 2.01E-04 : 7.42E-05 : 3.33E-06 : 5.13E-06 : 8.26E-04 : 2.85E-04 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_--+-________+-+__-__+
INFANT : 2.55E-06 : 1.67E-04 : 4.93E-05 : 3.07E-06 : 3.37E-06 : 7.57E-04 : 2.65E-04 : 0.00E+00 s
________-+__________+__________+__________+_________+__________+__________+_--________+__________+
TABLE 7.
DOSES TO MAXIMUM INDIVIDUAL (MREM),
JANUARY-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
4 A Nearest Cow AT 3.50 MILES NNW ANNUAL BETA AIR DOSE = 3.30E-04 MILLRADS ANNUAL GAMMA AIR DOSE
- 5.47E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+__________+--
-__ ____+__________+__________+__________+__________+___-
-_____+____--_
_ +
PLUME
- 3.67E-04 : 3.67E-04 : 3.67E-04 : 3.67E-04 : 3.67E-04
- 3.67E-04 : 3.70E-04 : 7.15E-04 :
__+__-4
__+_--+ -
_______+_
________+__
_______+___
______+____
_____+____-
-_____+____--_
_ +
GROUND
- 1.95E-05 : 1.95E-05 : 1.95E-05 : 1.95E-05 : 1.95E-05 : 1.95E-05 : 1.95E-05
- 2.30E-05 :
-________+__________+-
+___
_+
__-----+
-___+_--__
_+
VEGET ADULT 2.35E-05 1.25E-04 7.65E-04 2.72E-06
- 3.78E-06
- 6.51E-04 1.17E-08 0.OOE+00
-________+__________+-
+___
_+
__---+
+
-___+_--__+
TEEN
- 3.85E-05 : 1.53E-04 : 1.27E-03 : 4.12E-06 : 5.72E-06 : 8.76E-04 2 2.18E-08 : 0.OOE+00 :
-________+__________+--+
+_____
+
+
+ __--+-+_____+__--___+
CHILD
- 9.23E-05 : 1.21E-04 : 3.09E-03 : 6.78E-06 : 9.14E-06 : 1.68E-03 : 3.32E-08 : 0.OOE+00 :
-________+__________+--+
+_____+
_+
_____+
__--+-+_____+__--_
+
MEAT s
s s
ADULT s 4.38E-07 2.08E-06 s 7.56E-06 3.49E-07 2.64E-07 s 1.75E-05 9.46E-10 0.OOE+00
-________+__________+-
+___
_+
__-----+
-___+_--__
_+
TEEN
- 3.54E-07 : 1.22E-06 : 6.35E-06 s 2.71E-07 s 2.02E-07 s 1.27E-05 s 8.95E-10 s 0.OOE+00 s
________+__--______+_--_--______+__________+__________+__________+__________+__--+-+_____+__--__+
CHILD s 6.02E-07 : 6.97E-07 : 1.20E-05 : 3.22E-07 : 2.39E-07 : 1.91E-05 : 1.05E-09 : 0.00E+00 :
-________+__________+-
+___
_+
__---+
+
_+_--__
_+
COW MILK :
O ADULT
- 2.38E-06
- 7.56E-06 3.70E-05 2.57E-06 3.28E-06 4.88E-04 : 7.97E-09 0.OOE+00 TEEN
- 4.13E-06
- 1.OOE-05 : 6.80E-05 : 4.47E-06
- 5.73E-06
- 7.73E-04 : 1.65E-08 : 0.OOE+00 :
CHILD
- 8.87E-06 : 7.78E-06 : 1.68E-04 : 7.39E-06
- 9.33E-06
- 1.53E-03 : 2.53E-08 : 0.OOE+00 :
_________+__________+--+-
+_____+___
_+_____
_____+__--+-+_+_+_+__--_
+
INFANT : 1.59E-05 : 1.09E-05 : 3.17E-04 : 1.62E-05 : 1.56E-05
- 3.72E-03 : 4.58E-08 : 0.OOE+00
_________+__________+--+ -
+_
+
+
+
__---_____+_____--_
+
GOATMILK:
ADULT
- 3.36E-06 1.25E-05 : 7.62E-05 2.15E-06 : 3.27E-06 5.86E-04 2.39E-08 0.OOE+00
+-------+--
+----------------------------+-
-+-
-+-
+---
TEEN
- 5.86E-06 : 1.71E-05 : 1.40E-04 : 3.80E-06 : 5.81E-06 : 9.28E-04 : 4.94E-08 0.OOE+00 :
+-------+--
+----------------------------+-
-+-
-+-
+---
CHILD
- 1.31E-05 : 1.37E-05 : 3.46E-04 : 6.57E-06 : 9.64E-06 : 1.84E-03 : 7.59E-08 : 0.OOE+00 :
+-------+--
+----------------------------+-
-+-
-+-
+---
INFANT : 2.47E-05 : 1.42E-05 : 6.56E-04 : 1.55E-05 : 1.67E-05 : 4.46E-03 : 1.37E-07 : 0.OOE+00 :
+-------------------+--
+------------------++
+--+-----
INHAL 2
ADULT : 3.05E-07 : 5.35E-06 : 4.32E-06 s 3.83E-07 s 5.17E-07 s 6.45E-05 2.09E-05 s 0.OOE+00
_________+__________+--+-
+_____+___
_+__________+__-
+_____+__--_
+
TEEN s 4.18E-07 s 7.07E-06 s 6.14E-06 s 5.26E-07 s 7.12E-07 s 8.11E-05 s 3.56E-05 : 0.OOE+00 s
_________+__________+-
+___
_+
__--+-+
-+
-+
_+_--__
_+
CHILD s 5.17E-07 s 1.62E-05 s 8.43E-06 s 5.15E-07 : 6.68E-07 s 9.43E-05 s 3.16E-05 : 0.OOE+00 s
_______-_+-_________+_____-____+_______-__+________-_+________-_+________-_+________-_+_______-_+
INFANT s 3.55E-07 s 1.32E-05 s 5.61E-06 s 4.75E-07 s 4.39E-07 : 8.65E-05 : 2.94E-05 : 0.OOE+00 s
_______-_+-_________+______-___+_________-+________-_+_________-+________-_+________-_+________-_+
TABLE 7. DOSES TO MAXIMUM INDIVIDUAL (MREM), JANUARY-DECEMBER 2004 (CONTINUED)
SPECIAL LOCATION NO.
5 A Nearest Garden AT 1.20 MILES SE ANNUAL BETA AIR DOSE w 1.86E-04 MILLRADS ANNUAL GAMMA AIR DOSE a 2.65E-04 MILLRADS PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
+ __________+__________+__________+__________+__________+__________+___-
+__
+
PLUME
- 1.78E-04 : 1.78E-04 : 1.78E-04 : 1.78E-04 : 1.78E-04 : 1.78E-04 : 1.80E-04 3.70E-04 :
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
GROUND
- 1.36E-04 : 1.36E-04 : 1.36E-04 : 1.36E-04 : 1.36E-04 : 1.36E-04 : 1.36E-04 : 1.60E-04 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
VEGET s
I s
s s
ADULT
- 1.63E-04 : 8.64E-04 : 5.31E-03 : 1.83E-05 : 2.65E-05 : 4.67E-03 : 3.96E-08 : 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
TEEN s 2.67E-04 : 1.06E-03 : 8.80E-03 : 2.77E-05 : 4.OOE-05 : 6.29E-03 : 7.41E-08 : 0.OOE+00 I
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
CHILD
- 6.41E-04 : 8.41E-04 : 2.15E-02 : 4.57E-05 : 6.41E-05 : 1.21E-02 : 1.13E-07 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
MEAT ADULT 2.87E-06 1.40E-05 5.24E-05 2.05E-06 1.60E-06 1.26E-04 3.21E-09 0.OOE+00
-+__________+__________+__________+
_________+__________+__________+_--+
-__+_____+_+-_
_+
TEEN
- 2.33E-06 : 8.23E-06 : 4.40E-05 : 1.59E-06 : 1.23E-06 : 9.09E-05 : 3.04E-09 : 0.00E+00 :
________-+__________+__________+__________+_________+__________+__________+_--+-+-____+__-+__-__+
CHILD
- 3.99E-06 : 4.72E-06 : 8.30E-05 : 1.90E-06 : 1.47E-06 : 1.37E-04 : 3.57E-09 : 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
COW MILK:
ADULT
- 1.59E-05 : 4.92E-05 : 2.57E-04 : 1.65E-05 : 2.23E-05 3.51E-03 : 2.71E-08 : 0.OOE+00
-+__________+__________+__________+
_________+__________+__________+_--+-
+
+-____+_+-_
_+
TEEN
- 2.78E-05 : 6.57E-05 : 4.72E-04 : 2.88E-05 : 3.92E-05 : 5.55E-03 : 5.59E-08 : 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_--4.-______+__________
CHILD
- 5.99E-05 : 5.16E-05 : 1.16E-03 : 4.81E-05 : 6.41E-05 : 1.10E-02 : 8.59E-08 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_---________-+____-__+
INFANT : 1.08E-04 : 6.90E-05 : 2.21E-03 : 1.07E-04 : 1.08E-04 : 2.67E-02 : 1.55E-07 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
GOATMILK :
ADULT
- 2.30E-05 8.69E-05 5.30E-04 1.44E-05 2.30E-05 4.21E-03 8.11E-08 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---________+-+___-__+
TEEN
- 4.05E-05 : 1.19E-04 : 9.73E-04 : 2.55E-05 : 4.10E-05 : 6.66E-03 : 1.68E-07 : 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_----_______-________+
CHILD
- 9.13E-05 : 9.53E-05 : 2.40E-03 : 4.42E-05 : 6.80E-05 : 1.32E-02 : 2.58E-07 : 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_--+-+-+-+-_+__+______
INFANT : 1.73E-04 : 9.82E-05 : 4.56E-03 : 1.06E-04 : 1.18E-04 : 3.20E-02 : 4.66E-07 : 0.OOE+00 :
_________+__________+__________+__________+__________+__________+__________+__________+__________+
INHAL ADULT 1.12E-06 2.31E-05 : 1.93E-05 1.25E-06 2.05E-06 2.96E-04 9.53E-05 0.OOE+00
________-+__________+__________+__________+_________+__________+__________+_---+-+-+-___-+___-__+
TEEN
- 1.53E-06 : 3.31E-05 : 2.75E-05 : 1.72E-06 : 2.82E-06 : 3.72E-04 : 1.63E-04 : 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_--+________+__________
CHILD
- 1.89E-06 : 1.01E-04 : 3.78E-05 : 1.68E-06 : 2.65E-06 : 4.33E-04 : 1.45E-04 : 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_--+-+-+-+-+-+-+__-__+
INFANT : 1.29E-06 : 8.39E-05 : 2.51E-05 : 1.55E-06 : 1.74E-06 : 3.97E-04 : 1.35E-04 : 0.OOE+00 :
________-+__________+__________+__________+_________+__________+__________+_--________+____-____+
TABLE 8. DOSES TO POPULATION WITHIN 50 MILES, JANUARY-MARCH 2004 ALARA ANNUAL INTEGRATED POPULATION DOSE
SUMMARY
(PERSON-REM)
PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+__________+-
_______+_
________+__
_______+___
______+____
_____+____-
-_____+____--_
+
PLUME 1.97E-04 : 1.97E-04 : 1.97E-04 : 1.97E-04 : 1.97E-04 : 1.97E-04 : 2.OOE-04 : 4.58E-04
- 98.48% :
98.00% :
91.34% :
97.73% :
96.62% :
14.26% :
99.18% :
99.89%
_________+__________+-
-_+_________________+_____+__----+_____+__--_
_+
GROUND 4.17E-07 : 4.17E-07 : 4.17E-07 : 4.17E-07 : 4.17E-07
- 4.17E-07 : 4.17E-07 : 4.90E-07
.21% :
.21% :
.19% :
.21% :
.20% :
.03% :
.21% :
.11%
_________+__________+-
+___
_+
__-----+
_+_--___
_+
INHAL 2.03E-07 : 1.81E-06 : 4.43E-07 : 4.23E-07 : 7.08E-07
- 1.06E-04 t 1.20E-06 : 0.OOE+00
.10% :
.90% :
.21% :
.21% :
.35% :
7.65% :
.59% :
.00% :
________+__--______+_--_--______+__________+__________+__________+__________+__----+_____+__--__+
VEGET
- 4.19E-07 : 9.84E-07 : 1.27E-05 : 1.99E-07 : 1.19E-07 : 1.26E-05 : 1.88E-08 0.OOE+00 :
.21% :
.49% :
5.85% :
.10% :
.06% :
.91% :
.01% :
.00%
_________+__________+-
_--____--_+__
+_
+
____+
+
COW MILK 1.97E-06 : 7.60E-07 : 4.94E-06 : 3.46E-06 : 5.54E-06 : 1.05E-03 : 2.48E-08 0.OOE+00
.98% :
.38%
2.28% :
1.71% :
2.71% :
75.59% :
.01% :
.00%
_________+__________+-
+___
_+
__-----+
-___+_--__
_+
MEAT 5.06E-08 : 4.97E-08 : 2.71E-07 : 7.94E-08 : 1.18E-07 : 2.16E-05 : 1.48E-09 : 0.OOE+00
.03% :
.02% :
.13%
.04% :
.06% :
1.56% :
.00% :
.00%
+---------------------------------------------------------------------+--_______--+----+
- TOTAL*
- 2.01E-04 : 2.01E-04 : 2.16E-04 : 2.02E-04 : 2.04E-04 : 1.38E-03 : 2.02E-04 : 4.59E-04
_________+__________+--+-
+_____+___
_+__________+__--+-+_+_+_+__--_
_+
TABLE 9. DOSES TO POPULATION WITHIN 50 MILES, APRIL-JUNE 2004 Cooper Q2 2004 ALARA ANNUAL INTEGRATED POPULATION DOSE
SUMMARY
(PERSON-REM)
PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+______-___+_________-+__________+_________-+________-_+________-_+________-_+________-_+
PLUME 9.89E-06 : 9.89E-06 : 9.89E-06 : 9.89E-06 : 9.89E-06 : 9.89E-06 : 1.01E-05 : 2.72E-05 79.25% :
75.86% :
54.07% :
70.40% :
59.43% :
.82% :
88.41% s 98.49%
_________+-_________+_________-+_________-+________-_+________-_+________-_+________-_+________-_+
GROUND 3.55E-07
- 3.55E-07 : 3.55E-07
- 3.55E-07
- 3.55E-07
- 3.55E-07 : 3.55E-07 : 4.18E-07 2.84% :
2.72% :
1.94% :
2.53% s 2.13% :
.03% :
3.11% :
1.51%
_________+-_________+_________-+_________-+_________-+________-_+________-_+________-_+________-_+
INHAL
- 1.96E-07 : 1.73E-06 : 3.44E-07
- 4.16E-07
- 6.99E-07 : 1.04E-04 : 9.65E-07 0.OOE+00 1.57% :
13.31% :
1.88% :
2.96% :
4.20% :
8.60% :
8.47% :
.00%
-________+__________+_________-4+___-_____+________-_+_________-+_________-+_________-+_________-+
VEGET 1.33E-07 : 3.46E-07 : 4.24E-06
- 4.10E-08
- 6.61E-08 : 1.27E-05 : 2.16E-11 0.00E+00 1.06% :
2.65% :
23.16% :
.29% :
.40% :
1.05% :
.00% :
.00%
_________+-_________+_______-__+_________-+________-_+________-_+________-_+________-_+________-_+
COW MILK 1.86E-06
- 6.62E-07 : 3.34E-06
- 3.28E-06
- 5.52E-06 : 1.06E-03 : 1.74E-11 0.OOE+00 14.94% :
5.07% :
18.25% :
23.34% :
33.15% :
87.70% :
.00% :
.00%
_________+______-___+_________-+________-_+_________-+________-_+________-_+________-_+________-_+
NEAT 4.15E-08 : 5.09E-08 : 1.28E-07
- 6.73E-08 : 1.14E-07 : 2.17E-05 : 1.02E-11 : 0.OOE+00
.33% :
.39% :
.70% :
.48% :
.68% :
1.81%
.00% :
.00%
_________+__________+__________+__________+__________+__________+__________+__________+__________+
- TOTAL*
- 1.25E-05 : 1.30E-05 s 1.83E-05 : 1.40E-05 : 1.66E-05 : 1.20E-03 : 1.14E-05 : 2.76E-05
_________+__________+__________+__________+__________+__________+__________+__________+__________+
TABLE 10.
DOSES TO POPULATION WITHIN 50 MILES, JANUARY-JUNE 2004 ALARA ANNUAL INTEGRATED POPULATION DOSE
SUMMARY
(PERSON-REM)
PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+-_________+_____-____+_________-+________-+__________+__________+____-_---___+-________+
PLUME 1.97E-04 : 1.97E-04 : 1.97E-04 : 1.97E-04
- 1.97E-04 t 1.97E-04 : 2.00E-04 : 4.60E-04 97.20% :
96.50% :
87.86% :
95.74% :
93.51%
7.63% :
98.54% :
99.80%
_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+
GROUND 7.76E-07 : 7.76E-07 : 7.76E-07 : 7.76E-07 : 7.76E-07 : 7.76E-07 : 7.76E-07 : 9.13E-07
.38% :
.38% :
.35% :
.38% :
.37% :
.03% :
.38% :
.20%
_________+______-___+_________-+________-_+_________-+________-_+________-_+________-_+________-_+
INHAL
- 4.OOE-07
- 3.51E-06 : 7.86E-07 : 8.41E-07
- 1.41E-06 : 2.10E-04 : 2.14E-06 : 0.OOE+00 :
.20% :
1.72% :
.35% :
.41% :
.67% :
8.14% :
1.06% :
.00%
_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+
VEGET 5.54E-07 : 1.33E-06 : 1.69E-05 : 2.46E-07
- 1.87E-07 : 2.53E-05 : 1.95E-08 : 0.OOE+00
.27% :
.65%
7.57% :
.12% :
.09% :
.98% :
.01% :
.00%
_________+-_________+_______-__+_________-+_________-+-_________+__________+_________-+________-_+
COW MILK 3.84E-06 : 1.42E-06 : 8.29E-06 : 6.75E-06 : 1.11E-05 : 2.10E-03 : 2.60E-08 : 0.OOE+00 1.90% :
.70% :
3.70% :
3.28% :
5.25% :
81.54% :
.01% :
.00%
_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+
MEAT 9.23E-08
- 1.OOE-07 : 3.99E-07 : 1.47E-07 : 2.31E-07 : 4.34E-05 : 1.55E-09 0.OOE+00
.05% ;
.05% :
.18% :
.07% :
.11% :
1.68% :
.00% :
.00%
_________+______-___+_________-+________-_+________-_+________-_+________-_+________-_+________-_+
- TOTAL*
- 2.02E-04 : 2.04E-04 : 2.24E-04 : 2.05E-04 : 2.10E-04 : 2.58E-03 : 2.02E-04 : 4.61E-04
_______-_+-_________+______-___+_________-+__________+__________+__________+_________-+________-_+
TABLE 11.
DOSES TO POPULATION WITHIN 50 MILES, JULY-SEPTEMBER 2004 ALARA ANNUAL INTEGRATED POPULATION DOSE
SUMMARY
(PERSON-REM)
PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-________+__________+-
+___
_+
__-----+
-_ _+_--___
_+
PLUME 9.72E-06
- 9.72E-06
- 9.72E-06 : 9.72E-06 : 9.72E-06 : 9.72E-06 : 9.87E-06 : 2.36E-05 43.40% :
36.64% :
27.27% :
41.52% :
37.88% :
.87% :
42.69% :
66.64%
-________+__________+-
+___
_+
-+
_____+
GROUND
- 1.01E-05
- 1.01E-05
- 1.01E-05 : 1.01E-05
- 1.01E-05 : 1.01E-05 : 1.01E-05 : 1.18E-05 44.93% :
37.93% :
28.23% :
42.99% :
39.21% :
.90% :
43.54% :
33.36%
-________+__________+-
_______+_
________+__
_______+___
______+____
_____+____-
-_____+____--_
+
INHAL 2.20E-07 : 3.19E-06 : 4.62E-07 : 4.43E-07 : 7.24E-07 : 1.09E-04 : 3.19E-06 : 0.OOE+00
.98% :
12.03% :
1.30% :
1.89% :
2.82% :
9.77% :
13.78% :
.00%
_________+__________+-
+___
_+
+
-__+
+
VEGET 5.34E-07 : 2.22E-06 : 1.06E-05 : 1.21E-07 : 5.99E-08 : 1.15E-05 : 1.80E-11 : 0.OOE+00 2.38% :
8.38% :
29.80% :
.51% :
.23% :
1.03% :
.00% :
.00%
_________+__________+-
+___
_+
-___+___--_
_+
COW MILK 1.76E-06 : 8.71E-07 : 4.53E-06 : 2.98E-06 : 4.99E-06 : 9.57E-04 : 1.43E-11 : 0.OOE+00 7.86% :
3.28% :
12.71% :
12.72% :
19.45% :
85.66% :
.00% :
.00%
_________+__________+-
+___
_+
+
-__+
+
MEAT
- 9.99E-08 : 4.59E-07 : 2.48E-07 : 8.61E-08 : 1.04E-07 : 1.98E-05 : 8.62E-12 0.OOE+00
.45% :
1.73% :
.70% :
.37% :
.40% :
1.77% :
.00% :
.00%
-________+__________+-
+___
_+
__---+
-+
-+
_+_--__+
- TOTAL*
- 2.24E-05 : 2.65B-05 : 3.57E-05 : 2.34E-05 : 2.57E-05 : 1.12E-03 : 2.31E-05 : 3.55E-05
-________+__________+-
+___
_+
__-----+
-___+_--__
_+
00
TABLE 12.
DOSES TO POPULATION WITHIN 50 MILES, OCTOBER-DECEMBER 2004 ALARA ANNUAL INTEGRATED POPULATION DOSE
SUMMARY
(PERSON-REM)
PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
________-+__________+__________+__________+_________+__________+__________+_--________+____-____+
PLUME 1.33E-04 : 1.33E-04 : 1.33E-04 s 1.33E-04
- 1.33E-04
- 1.33E-04 : 1.35E-04
- 3.00E-04 48.73% :
26.94% :
4.39% :
66.49% :
67.57% :
8.99% :
45.56% :
84.21%
_________+-_________+______-___+__________+______-4_-+_________-+________-_+_________-+________-_+
GROUND 4.79E-05
- 4.79E-05
- 4.79E-05 : 4.79E-05 : 4.79E-05 4.79E-05
- 4.79E-05
- 5.64E-05 17.60% :
9.73% :
1.59% :
24.01% :
24.40% :
3.25% :
16.23% :
15.79%
_________+-_________+______-___+_______-__+________-_+________-_+________-_+_________-+_________+-
INHAL
- 9.23E-07 : 2.22E-05
- 2.47E-05 : 4.45E-07 : 6.58E-07
- 9.77E-05 : 1.13E-04 : 0.00E+00
.34% :
4.50% :
.82% :
.22% :
.34% :
6.62% :
38.16% :
.00%
_________+__________+_____-__-___+_______+________-_+________-_+________-_+__________+_____-__-_+
VEGET 6.86E-05 : 2.32E-04 : 2.33E-03
- 3.07E-06
- 1.58E-06
- 1.42E-05 : 5.02E-08 : 0.00E+00 25.17% :
47.17% :
77.00% :
1.54% :
.81% :
.96% :
.02% :
.00%
________+-_________+_______-__+________-_+__________+_________-+__________+_____-__-_+________-_+
COW MILK 2.00E-05
- 4.91E-05
- 4.48E-04 : 1.39E-05 : 1.25E-05
- 1.16E-03 : 6.75E-08 : 0.00E+00 7.36% :
9.97% :
14.82% :
6.96% :
6.38% :
78.54% :
.02%
.00%
_________+-_________+________-_+__________+__________+______-__-+_________-+________-_+________-_+
MEAT
- 2.20E-06
- 8.37E-06 : 4.17E-05 : 1.56E-06 : 1.OOE-06
- 2.41E-05 : 3.98E-09 0.00E+00
.81% :
1.70% :
1.38% :
.78% :
.51% :
1.64% :
.00% :
.00%
+__________+__________+-_________+__________+__-_-____+__-__-_
- TOTAL*
- 2.72E-04
- 4.93E-04
- 3.02E-03 : 2.00E-04 : 1.96E-04
- 1.48E-03 : 2.95E-04
- 3.57E-04
_________+_-_________+__________+__________+_________+__________+__________+_---+-_______-+____-__
TABLE 13.
DOSES TO POPULATION WITHIN 50 MILES, JULY-DECEMBER 2004 ALARA ANNUAL INTEGRATED POPULATION DOSE
SUMMARY
(PERSON-REM)
PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
-__________________+___---______+____________________+_________+__________+____--+-_____-+_--____+
PLUME
- 1.62E-04
- 1.62E-04 : 1.62E-04 : 1.62E-04
- 1.62E-04 : 1.62E-04
- 1.64E-04 : 3.67E-04 50.73% :
29.65% :
5.25% :
65.46% :
65.71% :
6.18% :
46.03% :
83.26%
-________+__________+-
+___
_+
__---+
+
-___+_--__+
GROUND 6.28E-05
- 6.28E-05 : 6.28E-05 : 6.28E-05 : 6.28E-05 : 6.28E-05 : 6.28E-05 : 7.39E-05 19.69% :
11.51% :
2.04% :
25.41% :
25.50% :
2.40% :
17.63% :
16.74%
_________+__________+--+-
+_____+___
_+__________+__----+_+___+__--_
_+
INHAL 1.24E-06 : 2.78E-05
- 2.81E-05
- 9.03E-07 : 1.40E-06 : 2.09E-04 : 1.29E-04 : 0.OOE+00
.39% :
5.09% :
.91% :
.37% :
.57% :
7.98% :
36.31% :
.00%
_________+__________+--+---______+_________+_________+_________+_________+____--._____+__________+
VEGET 6.91E-05 : 2.35E-04
- 2.34E-03
- 3.19E-06
- 1.64E-06 : 2.57E-05 : 5.01E-08 : 0.OOE+00 21.65% :
42.99% :
75.78% :
1.29% :
.67%
.98% :
.01% :
.00%
-________+__________+--+--_______+__________+__________+__________+__________+_----+--___-+__--__+
COW MILK 2.18E-05 : 5.00E-05 : 4.52E-04
- 1.68E-05
- 1.75E-05 : 2.11E-03
- 6.72E-08 0.OOE+00 6.83% :
9.15% :
14.66% :
6.81% :
7.10% :
80.78% :
.02% :
.00%
_________+__________+-
___-------+_
_+
__--+-+
-+
-+
_+_--__
_+
MEAT 2.30E-06 : 8.84E-06
- 4.20E-05
- 1.65E-06
- 1.11E-06 : 4.39E-05
- 4.OOE-09 0.OOE+00
.72% :
1.62% :
1.36% :
.67% :
.45% :
1.68% :
.00% :
.00%
_________+__________+-
+___
_+
__--+-+
-+
-+
.9___
- TOTAL*
- 3.19E-04 : 5.46E-04 : 3.08E-03
- 2.47E-04 : 2.46E-04
- 2.62E-03
- 3.56E-04 : 4.41E-04
-________+__________+--_--_______+__________+__________+__________+__________+_--+---___+_+__--__+
U'
TABLE 14.
DOSES TO POPULATION WITHIN 50 MILES, JANUARY-DECEMBER 2004 Cooper An 2004 ALARA ANNUAL INTEGRATED POPULATION DOSE
SUMMARY
(PERSON-REM)
PATHWAY T.BODY GI-TRACT BONE LIVER KIDNEY THYROID LUNG SKIN
+ __________+__________+__________+__________+__________+__________+___-
+-___
PLUME 3.57E-04 3.57E-04 : 3.57E-04 3.57E-04
- 3.57E-04
- 3.57E-04 : 3.62E-04
- 8.23E-04 68.95%
47.95% :
10.83%
79.46% :
78.76% :
6.87% :
65.72% :
91.88%
_________+-_________+_______-__+________-_+________-_+________-_+________-_+________-_+________-_+
GROUND
- 6.18E-05 : 6.18E-05 : 6.18E-05 : 6.18E-05 : 6.18E-05 : 6.18E-05 : 6.18E-05 : 7.27E-05 11.94% :
8.30% :
1.88% :
13.76% :
13.64% :
1.19% :
11.22% :
8.12%
_________+_-_________+__________+__________+_________+__________+__________+_--4________+-_______+
INHAL
- 1.61E-06 : 3.03E-05 : 2.79E-05 : 1.75E-06 : 2.81E-06
- 4.20E-04 : 1.27E-04
- 0.OOE+00
.31% :
4.08% :
.85% :
.39% :
.62% :
8.08% t 23.03% :
.00%
_________+-_________+________-_+__________+________--+________-_+__________+__________+___-__-___+
VEGET 6.94E-05 : 2.35E-04 : 2.35E-03 : 3.42E-06 : 1.82E-06 : 5.09E-05 : 6.93E-08 0.OOE+00
- 13.41% :
31.60% :
71.23% :
.76% :
.40% :
.98% :
.01% :
.00%
_________+__________+__________+__________+-__-______+________-_+________-_+__________+______-__-_
COW MILK 2.55E-05 : 5.11E-05 : 4.59E-04 : 2.35E-05 : 2.85E-05 : 4.22E-03 : 9.27E-08 0.OOE+00 4.93% :
6.87% :
13.93% :
5.23% :
6.29% :
81.19% :
.02% :
.00%
_________+______-___+_________-+________-_+________-_+_________-+________-_+________-_+________-_+
MEAT 2.38E-06 : 8.90E-06 : 4.22E-05 : 1.78E-06 1.33E-06 : 8.72E-05 : 5.52E-09 0.OOE+00
.46% :
1.20% :
1.28% :
.40%
.29% :
1.68% :
.00% :
.00%
_________+_-_________+__________+__________+_________+__________+__________+_--________+____-____+
- TOTAL*
- 5.18E-04 : 7.44E-04 : 3.29E-03 : 4.49E-04
- 4.53E-04
- 5.19E-03 : 5.51E-04 : 8.95E-04
________-+__________+__________+__________+_________+__________+__________+_--________+__________+
DOSE CALCULATION MODELS To evaluate the radiological consequences of the routine release of liquid and gaseous effluents from the Cooper Nuclear Station, two computer codes were used: LADTAP II for liquid doses and GASPAR for gaseous doses. Both of these computer codes implement the dose calculational methodologies of U.S. NRC Regulatory Guide 1. 109, Revision 1.
Source terms for each quarter are combined with station-specific demographic data and either hydrological dilution factors, for liquid dose calculations, or atmospheric diffusion estimates, for gaseous dose calculations.
For liquid dose calculations, the hydrological dilution factors used for input to LADTAP II, as well as other input parameters, are listed in Table 12. Other inputs not specifically listed in this table are taken from Regulatory Guide 1.109, Revision 1. Semiannual doses are obtained by summing the contributions from the appropriate quarters.
For gaseous dose calculations, atmospheric diffusion estimates are obtained from the reduction and processing of onsite meteorological data, as described in Appendix B. Source terms for the semiannual period are obtained by summing source terms for the appropriate quarters. Additional input to GASPAR includes the following station-supplied data:
0 to 50 mile population distribution 0 to 50 mile meat, milk, and vegetable distributions Absolute humidity at Cooper Nuclear Station (14.61 g/m3)
The fraction of the year that the vegetables are grown (0.5)
The fraction of the daily feed intake derived from pasture for milk and meat animals (0.5)
Other values used for input to GASPAR are default values from Regulatory Guide 1.109, Rev. 1.
F52
TABLE 15.
Values of Parameters Used to Make Dose Estimates Resulting From Liquid Discharges at Cooper Nuclear Station January-December 2004 Values Assigned Parameter Individual Population NO LIQUID EFFLUENTS RELEASED IN 2004 F53
REFERENCES U.S. Nuclear Regulatory Commission, Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants", Revision 1, 1974.
U.S. Nuclear Regulatory Commission, Regulatory Guide 1.23 (Safety Guide 23), "Onsite Meteorological Programs", Revision 0, 1972.
U.S. Nuclear Regulatory Commission, Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors", Revision 1, 1977.
U.S. Nuclear Regulatory Commission, NUREG/CR-2919, "XOQDOQ: Computer Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations", 1982.
U.S. Nuclear Regulatory Commission, Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors", Revision 0, 1976.
U.S. Nuclear Regulatory Commission, NUREG-0597, "User's Guide to GASPAR Code",
December 1980.
U.S. Nuclear Regulatory Commission, NUREG/CR-1276, "User's Manual for LADTAP II: A Computer Code for Calculating Radiation Exposure to Man From Routine Release of Nuclear Reactor Liquid Effluents", 1980.
U.S. Nuclear Regulatory Commission, Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR 50, Appendix I", Revision 1, 1977.
F54
APPENDIX G REMP SAMPLE STATION DESCRIPTIONS G-1
REMP SAMPLE STATION DESCRIPTIONS The following pages contain descriptions of the CNS REMP Sample Stations that were active or were used for part or all of 2004.
G-2
REMP SAMPLE STATION DESCRIPTIONS SAMPLE TYPES AND SAMPLE LOCATIONS Sample Station (a)
Sample Description - Type and Location No. 1 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Outside the northwest edge of fence, east of the gate to the LLRW storage pad on the CNS site, NW 14, S32, T5N, R16E, Nemaha County, Nebraska.
Lon. 095.38.634 W - Lat. 40.21.523 N No. 2 Type: (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: North side of county road to the south portion of CNS site, SW 1/4, S32, T5N, R16E, Nemaha County, Nebraska.
Lon. 095.38.954 W - Lat. 40.21.126 N No. 3 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Located on the north side of the Brownsville State Recreation Park access road near water gauging station, SE 14, SI8, T5N, R16E, Nemaha County, Nebraska.
Lon. 095.39.108 W - Lat. 40.23.777 N No. 4 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Located l/2 mile south of Phelps City, Missouri, on west side of highway "U", NE 1/4, S2, T64N, R42W, Atchison County, Missouri.
Lon. 095.35.792 W - Lat. 40.23.797 N No. 5 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Located 1/4 mile south and 1 mile east of Langdon, Missouri, on north side of road, wvest of railroad tracks, SW 1/44, T64N, R41W, Atchison County, Missouri.
Lon. 095.34.434 W - Lat. 40.21.151 N G-3 NOTES:
(a) Sample station numbers missing from the sequence are for inactive or discontinued sampling locations.
Sample Station (a)
Sample Description - Type and Location No. 6 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: One mile west of the end of Missouri State Highway "U", SW comer of the intersection, NW 1/4, S34, T64N, R42W, Atchison County, Missouri.
Lon. 095.37.620 W - Lat. 40.19.459 N No 7 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: 300 yards east of Highway 67 on north side of road, SW 1/4, S6, T4N, RI6E, Nemaha, Nebraska.
Lon. 095.40.207 W - Lat. 40.20.287 N No. 8 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location:
1/2 mile north, 3/4 mile west and 3/ mile north of Nemaha, on west side of road adjacent to transmission line, NE 1/4, S35, T5N, RISE, Nemaha County, Nebraska.
Lon. 095.41.220 W-Lat. 40.21.570 N No. 9 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: Four miles north of Highway 136, on Highway 67.
Then 1 mile east of Highway 67 and 1/2 mile north on west side of road, SW 1/4, S26, T6N, RI5E, Nemaha County, Nebraska.
Lon. 095.41.810 W - Lat. 40.27.259 N No. 10 Type (1) Air Particulate and Charcoal Filters (2) Environmental Thermoluminescent Dosimetry Location: One mile north of Barada, Nebraska, in SW corner of intersection, NE 14, S14, T3N, R16E, Richardson County, Nebraska.
Lon. 095.34.723 W - Lat. 40.13.970 N G-4 NOTES:
(a) Samplc station numbers missing from the sequence arc for inactive or discontinued sampling locations.
Sample Station (a)
Sample Description - Tvne and Location No. 11 Type: (1) Water-Ground Location: Plant well water supply header at well pits, NW 1/4, S32, T5N, R16E, Nemaha County, Nebraska.
Lon. 095.53.866 WV-Lat. 40.18.970 N No. 12 Type: (1) Water-River Location: Sample (1) taken from the Missouri River immediately upstream form the Plant Intake Structure (River Mile 532.5). During periods when unsafe conditions warrant, Station 35 may be used as an alternate upstream collection site.
Lon. 095.53.866 W - Lat. 40.18.970 N No.20 Type: (1) Environmental Thermoluminescent Dosimetry Location: On NNW boundary of NPPD property, east side of county road, SE, S30, T5N, R16E, Nemaha County, Nebraska.
Lon. 095.39.226 W - Lat. 40.22.260 N No.28 Type (1) Water-River, (2) Fish (3) Sediment from Shoreline (4) Food Products - Broadleaf Vegetation Location: Samples (1), (3), and (4) are taken from the Missouri River or its shore downstream near River Mile 530, Sample (2) is taken from the Missouri River l/2 to 3 miles downstream of the plant site.
Lon. 095.37.301 W-Lat. 40.20.336 N G-5 NOTES:
(a) Samplc station numbers missing from the sequence arc for inactive or discontinued sampling locations.
Sample Station (a)
Sample Description - Tvne and Location No. 35 Type (1) Fish (2) Water - River (Alternate Site)
(3) Food Products - Broadleaf Vegetation Location: Sample (1) will be taken from the Missouri River about 1 to 3 miles above the CNS intake structure. During periods when unsafe conditions warrant, Station 35 may be used as an alternate to Station 12 (upstream collection site) for sample type (2). Sample (3) is taken about 1/4 mile south of the Brownville State Recreation Area in Sector A.
Lon. 095.39.046 W - Lat. 40.23.737 N No. 44 Type: (1) Environmental Thermoluminescent Dosimetry Location:
1/4 mile south of Auburn Country Club on Highway 75, then 1/2 mile east of Highway 75 at fence line north of county road, SE1/4, S27, T5N, R14E, Nemaha County, Nebraska.
Lon. 095.49.759 W - Lat. 40.21.840 N No.47 Type: (1) Water -Ground Location: At Falls City Municipal water supply well.
Lon. 095.25.537 WV-Lat. 40.01.939 N No. 56 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1 1/4 miles SW of Langdon, Missouri, on Highway "U",
on the right side of the highway, NW 14, S23, T64N, R42W, Atchison County, Missouri.
Lon. 095.36.383 W - Lat. 40.21.157 N No. 58 Type: (1) Environmental Thermoluminescent Dosimetry Location: Three miles south of Brownville, Nebraska, on county road, at the SE corner of the intersection with the farm road leading to Sample Station No. 2, SE1/4, S31, T5N, R16E, Nemaha County, Nebraska.
Lon. 095.39.338 W - Lat. 40.21.126 N G-6 NOTES:
(a) Samplc station numbcrs missing from the scqucncc arc for inactive or discontinued sampling locations.
Sample Station (a)
Sample Description - Type and Location No. 59 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile SSE of the CNS Elevated Release Point, in the vicinity of the levee at the south boundary of NPPD property, SE 1/4, S32, T5N, R16E, Nemaha County, Nebraska.
Lon. 095.38.223 W - Lat. 40.20.986 N No. 66 Type: (1) Environmental Thermoluminescent Dosimetry Location: Two miles south of Nemaha, Nebraska, on Highway 67 east side of road, NW1/4, S19, T4N, R16E, Nemaha County, Nebraska.
Lon. 095.40.307 W - Lat. 40.18.277 N No. 67 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 miles west of Brownville, Nebraska, on Highway 136, then north 1 1/2 miles on county road and east 1/2 mile, on north side of road, NE1/4, Sl I, T5N, RISE, Nemaha County, Nebraska.
Lon. 095.41.520 W-Lat. 40.24.898 N No. 71 Type: (1) Environmental Thermoluminescent Dosimetry Location: Two miles east of Phelps City, Missouri, on Highway 36, then south 1 1/2 miles on county road and west 1/4 mile, SE1/4, S6, T64N, R41W, Atchison County, Missouri.
Lon. 095.34.727 W - Lat. 40.21.664 N No. 79 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1 7/8 miles south of Brownville, NE, on east side of paved road, NPPD property, SE 1/4, S30, T5N, RI6E, Nemaha County, Nebraska.
Lon. 095.39.238 W - Lat. 40.22.006 N G-7 NOTES:
(a) Samplc station numbers missing from the sequence arc for inactive or discontinued sampling locations.
Sample Station (a)
Sample Description - Tvne and Location No. 80 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 1/8 miles south of Brownville, on east side of paved road, NPPD property, NE1/4, S31, T5N, R16E, Nemaha County, Nebraska.
Lon. 095.39.259 W - Lat. 40.21.834 N No. 81 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 3/8 miles south of Brownville, Nebraska, in the NE comer of the intersection of the paved county road and CNS access road, NPPD property, NE1/4, S31, T5N, R16E, Nemaha County, Nebraska.
Lon. 095.39.291 W - Lat. 40.21.582 N No. 82 Type: (1) Environmental Thermoluminescent Dosimetry Location: 7/8 mile south of CNS in a field, on NPPD property, SW1/4, S32, T5N, R16E, Nemaha County, Nebraska.
Lon. 095.38.395 W - Lat. 40.20.961 N No. 83 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 /4 miles south of Nemaha, Nebraska, on Highway 67, then east I mile to the junction of the driveway and county road (east side of drive), NE1/4, S 19, T4N, R16E, Nemaha County, Nebraska.
Lon. 095.39.411 W - Lat. 40.18.119 N No. 84 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 V/2 miles west of Brownville, NE, south side of Highway 136 west of Locust Grove School, NWI/4, S22, T5N, RISE, Nemaha County, Nebraska.
Lon. 095.42.993 W - Lat. 40.23.564 N G-8 NOTES:
(a) Sample station numbers missing from the sequence arc for inactive or discontinued sampling locations.
Sample Station (a)
Sample Description - Tvne and Location No. 85 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile east of Brownville, Nebraska, on Highway 136, then north 14 mile on the east side of the county road, NE 1/4, S33, T65N, R42W, Atchison County, Missouri.
Lon. 095.38.309 W - Lat. 40.24.508 N No. 86 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile west of Phelps City, Missouri, on Highway 136, then north 1 1/2 miles on Highway "D" on west side, SE1/4, S22, T65N, R42W, Atchison County, Missouri.
Lon. 095.36.938 W - Lat. 40.25.563 N No. 87 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile west of Phelps City, Missouri, on Highway 136, then south '/2 mile on county road and 3/4 mile west on county road to the end of the road, NW 1/4, S3, T64N, R42W, Atchison County, Missouri.
Lon. 095.37.806 W - Lat. 40.23.818 N No. 88 Type: (1) Environmental Thermoluminescent Dosimetry Location: One mile west of Phelps City, Missouri, on Highway 136, then south 2 miles at the end of the county road, NW1/4, SIl, T64N, R42W, Atchison County, Missouri.
Lon. 095.37.771 W - Lat. 40.24.762 N No. 89 Type: (1) Environmental Thermoluminescent Dosimetry Location: 2 '/2 miles south of Phelps City, Missouri, on Highway "U", then 1/2 mile west in the SE comer of the county road intersection, NE1/4, S14, T64N, R42W, Atchison County, Missouri.
Lon. 095.36.361 W -Lat. 40.21.962 N G-9 NOTES:
(a) Sample station numbers missing from the sequence arc for inactive or discontinued sampling locations.
Sample Station (a)
Sample Description - Type and Location No. 90 Type: (1) Environmental Thermoluminescent Dosimetry Location: 1 1/2 miles west and 3/4 mile south of Langdon, Missouri, on Highway "U", then 1/4 mile west, SW1/4, S23, T64N, R42W, Atchison County, Missouri.
Lon. 095.35.808 W - Lat. 40.19.472 N No. 91 Type: (1) Environmental Thermoluminescent Dosimetry Location:
1/2 mile west of Rockport, Missouri, on the south side of the intersection of U.S. Highway 136 and U.S.
Highway 275, at the south side of the water tower, NW1/4, S28, T65N, R41W, Atchison County, Missouri.
Lon. 095.32.217 W - Lat. 40.25.181 N No. 94 Type: (1) Environmental Thermoluminescent Dosimetry Location:
1/4 mile of Langdon, Missouri, on the west side of the road, NE1/4, S24, T64N, R42W, Atchison County, Missouri.
Lon. 095.34.673 W - Lat. 40.20.931 N No. 96 Type: (1) Food products - Broadleaf Vegetation Location: Approximately I mile south of Brownville, Nebraska, along the paved road, in the road ditch in Sector R, SW1/4, S19, T5N, RI6E, Nemaha County, Nebraska.
Lon. 095.39.318 W - Lat. 40.23.144 N No. 99 Type: (1) Milk (Nearest and Other Producer)
Location: 1 % mile south of Shubert, Nebraska, on the west side of Highway 67, NE1/4, S24, T3N, RI5E, Richardson County, Nebraska.
Lon. 095.40.368 W - Lat. 40.12.850 N G-10 NOTES:
(a) Sample station numbers missing from the sequence arc for inactive or discontinued sampling locations.
Sample Station (a)
No. 100 No. 101 No. 102 Sample Description - Type and Location Type (1) Milk (Other Producer)
Location: Two miles south and 1 mile west of Shubert, Nebraska, SW1/4, S23, T3N, RI5E, Richardson County, Nebraska.
Lon. 095.42.556 W - Lat. 40.12.220 N Type: (1) Food Products - Broadleaf Vegetation Location: 5 1/2 miles east and 1/2 mile north of Rock Port, Missouri, near the junction of Highway 136 and Highway 59, in Sector D, encompasses portions of several sections, Athison County, Missouri.
Lon. 095.23.822 W - Lat. 40.25.222 N Type: (1) Milk (Other Producer)
Location: Two miles south and 3 miles east of Shubert, Nebraska, NW /4, S28, T3N, RI5E, Richardson County, Nebraska.
Lon. 095.38.081 W - Lat. 40.11.943 N Type: (1) Milk (Other Producer)
No. 103 Location: Four miles south and 3 miles west of Auburn, Nebraska, NE 1/4, S13, T4N, R13E, Nemaha County, Nebraska.
Lon. 095.53.865 W - Lat. 40.18.971 N G-1I NOTES:
(a) Sample station numbers missing from the sequence arc for inactive or discontinued sampling locations.