ML050670056
| ML050670056 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point (DPR-031) |
| Issue date: | 02/14/2005 |
| From: | Florida Power & Light Co |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| L-2005-046 | |
| Download: ML050670056 (8) | |
Text
/
' TURKEY POINT I-UNIT 3 CYCLE 21 7 SYSTEM PRESSURE TESTING o-FINAL REPORT tI Owner:
Florida Power and Light Company 700 Universe Blvd.
Juno Beach, Florida, 33408 Plant:
Florida Power and Light Company Turkey Point Nuclear Power Plant Unit 3 9760 SW 344 h St.
Florida City, Florida, 33035 Commercial Service Date:
Cycle 21 Service Dates:
Refueling Outage Dates:
December 14, 1972 March 28, 2003 thru December 02, 2004 September 26, 2004 thru December 02, 2004 Prepared By:
51
/&A &::
(/'.( 10, Date:
Z-/
/
Reviewed By:
Date:
A I 1 tl l s T Date:
Z It___1_
Approved By:
Page I of 8
- e Abstract This report details the pressure testing of selected ASME Class 1, 2 and 3 piping and components of Florida Power and Light Company's Unit 3 at the Turkey Point Nuclear Power Station. These tests were performed during Unit 3 cycle 21 completed during the fall refueling outage. The refueling outage occurred between the dates of September 26, 2004 and December 2, 2004. The complete cycle 21 was from March 28, 2003 to December 2, 2004. This pressure testing is being reported following the first outage of the first period for fourth ten-year interval for Turkey Point Unit 3.
Piping and components were selected and tested in accordance with Section Xl of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code "Rules for Inservice Inspection of Nuclear Power Components",
1998 Edition, 2000 addenda with specific relief as granted under 10 CFR 50.55a.
Procedures The following Florida Power and Light (FPL) procedures and documents have been implemented to provide instructional guidance for the performance of the required ASME Xl pressure testing and subsequent inspections.
0-ADM-523 3-OSP-041.25 3-OSP-045.1 3-OSP-045.2 3-OSP-041.2 NDE-4.2 ASME Section Xl Pressure Tests for Quality Group A, B, C Systems/Components.
RCS Overpressure Leak Testing ASME Section Xl Quality Group A Bolting Examination*
ASME Section Xl Quality Group B Bolting Examination*
Reactor Coolant System Visual Leak Inspection and Leak Evaluation.
Visual Examination VT-2 Conducted During System Pressure Tests.
- Relief Request No 18, Use of Code Case N-533 Authorized for Turkey Point Units 3 and 4 (TAC NOS. M98149 AND M98150).
System Summary:
The following safety related Class 1, 2, and 3 systems, or sections thereof were pressure tested in accordance with the requirements of the 1998 Edition, 2000 addenda ASME Section XI Code.
System Name System Number Intake Cooling Water 19 Component Cooling Water 30 Reactor Coolant 41 Chemical and Volume Control 47 Safety Injection 62 Main Steam 72 Auxiliary Feedwater 75 Page 2 of 8
Acronyms ADM:
ASME:
CSS:
CCW:
CVCS:
ECC:
FW:
HX:
ICW:
NDE:
PWO:
PZR:
RCP:
RHR:
RO:
RV:
RX:
SFPC:
SI:
SG:
XJ:
WO:
Administrative American Society of Mechanical Engineers Containment Spray System Component Cooling Water Chemical Volume Control System Emergency Containment Cooler Feedwater Heat Exchanger Intake Cooling Water Non Destructive Examination Plant Work Order Pressurizer Reactor Coolant Pump Residual Heat Removal Restricting Orifice Relief Valve Reactor Spent Fuel Pool Cooling Safety Injection Steam Generator Expansion Joint Work Order Page 3 of 8
Test Package Development The specific pressure test boundaries were selected after review of the applicable plant Operating diagram/code boundary drawings. The piping systems were broken into sub systems. The sub-systems were selected based on Technical Specifications operability requirements, acceptable isolation points and availability of test connections and vent valves. The sub-systems were then assigned test package numbers, which could be tested in entirety, or based on availability could be broken down further into numerous tests within the specific sub-system.
The pressure test package numbers contain six (6) segments of information, Sample:
04-CCW-30110 -L-01 A
A A
A A A 1
2 3 4 5 6
- 1.
Unit Number (00) common to both units 3 and 4. (03) Unit 3 specific and (04) Unit 4 specific.
- 2.
System abbreviation
- 3.
System number [First (2) digits].
- 4.
Sub-system number [(2) or (3) digits].
- 5.
Type of test (H) Hydrostatic, (P) Pneumatic, (L) Leakage
- 6.
Number of test performed within the specific sub-system.
Page 4 of 8
PRESSURE TEST PERFORMED DURING CYCLE 21 INTAKE COOLING WATER SYSTEM (19) 03-ICW-19117-L-01 Test Date: 10/28/2004 This test performed due to the replacement of valves 3-50-409 and 3-50-410 per WO#31007667-01. There was no leakage during this test.
03-ICW-19118-L-01 Test Date: 10/26/2004 This test performed due to replacement of valve 3-50-307 per WO# 31007526-
- 01. No leakage was observed during the test.
03-ICW-19130-L-01 Test Date: 11/26/2003 This test performed due to replacement of Valve 3-50-311 per WO#33020989-
- 01. There was no leakage observed during this test.
03-ICW-19131-L-01 Test Date: 10/26/2004 This test performed due to the replacement of valve 3-50-349 per WO#31022850-01. There was no leakage observed during this test.
03-ICW-19132-L-01 Test Date: 4/15/2004 This test performed due to replacement of valve 3-50-364 per WO#34006953-01.
There was no leakage observed during this test.
03-ICW-19133-L-01 Test Date: 10/26/2004 This test performed due to the replacement of valve 3-50-350 per WO#30006362-01. There was no leakage observed during this test.
03-ICW-19134-L-01 Test Date: 11/17/2004 This test performed due to replacement of Valve POV-3-4882 per WO#33000466-02. There was no leakage observed during this test.
03-ICW-19135-L-01 Test Date: 11/17/2004 This test performed due to replacement of Valve POV-3-4883 per WO#33013069-01. There was no leakage observed during this test.
03-ICW-19137-L-01 Test Date: 10/28/2004 This test performed due to replacement of a pipe elbow on BS-3-1403 per WO#34000031-01. There was no leakage observed during this test.
03-ICW-19138-L-01 Test Date: 8/20/2004 This Test performed due to the replacement of valve 3-50-377 per WO#34014914-01. There was no leakage observed during this test.
03-ICW-19140-L-01 Test Date: 10/3/2004 This test performed due to replacement of Valve 3-50-321 per WO#34017422-
- 01. There was no leakage observed during this test.
Page 5 of 8
COMPONENT COOLING WATER SYSTEM (30) 03-CCW-30327-L-01 Test Date: 10/26/2004 This test performed due to replacement of Valve 3-711 B per WO#31017889-01.
There was no leakage observed during this test.
03-CCW-30333-L-01 Test Date: 10/26/2004 This test performed due to the replacement of valve RV-3-1425 per WO#33021285-01. There was no leakage observed during this test.
03-CCW-30335-L-01 Test Date: 10/26/2004 This test performed due to replacement of Valve RV-3-1428 per WO#34000031-
- 01. There was no leakage observed during this test.
REACTOR COOLANT SYSTEM (41) 03-RCS-4101 -L-01 Test Date: 03/21/03 This test involved the leakage test of the Reactor Coolant System piping inside containment following the Unit 3 Cycle 21 Refueling Outage. This leakage test also addressed the following replacements:
Component Work Order #
Description RV-3-551A 33010523-01 Remove, install spare RV-3-551B 33010541-01 Remove, install spare RV-3-551 C 33010553-01 Remove, install spare No leakage was observed during this test.
CHEMICAL AND VOLUME CONTROL CHARGING AND LETDOWN SYSTEM (47) 03-CVCS-4775-L-01 Test Date: 8/31/2003 This test being performed due to replacement of valve 3-1315 per WO#32018395-01. There was no leakage observed during this test.
03-CVCS-4779-L-01 Test Date: 12/21/2003 This test performed due to replacement of the 3C Charging Pump per WO#33015127-01. There was no leakage observed during this test.
03-CVCS-4780-L-01 Test Date: 11/28/2004 This test performed due to replacement of valve 3-293B per WO# 32018647-01.
There was no leakage noted during this test.
Page 6 of 8
CVCS (cont.)
03-CVCS-4781-L-01 Test Date: 5/6/2004 This test performed due to replacement of the 3B Charging Pump Stuffing Boxes per WO#33021380-01. There was no leakage observed during this test.
03-CVCS-4782-L-01 Test Date: 7/3/2004 This test performed due to replacement of the 3A Charging pump block per WO# 34000755-01. There was no leakage observed during this test.
03-CVCS-4783-L-01 Test Date: 10/27/2004 This test performed due to replacement of Valve 3-269 per WO#34008570-01.
There was no leakage observed during this test.
03-CVCS-4784-L-01 Test Date: 9/22/2004 This test being performed due to the replacement of the valve bonnet on Valve 3-1315 per WO#34012308-01. There was no leakage observed during this test.
SAFETY INJECTION SYSTEM (62) 03-SI-6241-L-01 Test Date: 10/29/2004 This test performed due to replacement of Valve 3-873A per WO#31005377-01.
There was no leakage observed during this test.
03-SI-6242-L-01 Test Date: 10/29/2004 This test performed due to the replacement of valve 3-873B per WO#31005378-
- 01. There was no leakage observed during this test.
MAIN STEAM SYSTEM (72) 03-MS-7223-L-01 Test Date: 11/28/2004 This test being performed due to the replacement of the bonnet on Valve MOV 1400 per WO#34000317-01. There was no leakage observed during this test.
03-MS-7224-L-01 Test Date: 11/28/2004 This test being performed due to the replacement of the bonnet of Valve MOV 1401 per WO#33021534-02. There was no leakage observed during this test.
03-MS-7225-L-01 Test Date: 11/28/2004 This test being performed due to the replacement of the bonnet on Valve MOV 1402 per WO#34000316-01. There was no leakage observed during this test.
Page 7 of 8
AUX FEEDWATER SYSTEM (75) 03-AFW-7569-L-01 Test Date: 9/3/2004 This test was performed due to a modification to the "B" Auxiliary Feedwater Pump per PCM 03-095 and WO#33015160-07. There was no leakage observed during the test.
03-AFW-7570-L-01 Test Date: 12/01/2004 This test was performed due to the replacement of piping downstream of Valve AFPD-3-008 per WO# 34006019-03. No leakage was observed during the test.
03-AFW-7571-L-01 Test Date: 11/16/2004 This test performed due to replacement of Valve 3-20-401 per WO#34000703-
- 01. There was no leakage observed during this test.
03-AFW-7572-L-01 Test Date: 12/1/2004 This test performed due to the replacement of Aux. Feed 90 deg. elbow upstream of valve 3-20-139 per WO# 34018922-01. No leakage was observed during this test.
BOLTED JOINT EXAMINATIONS The bolted joint examinations were performed in accordance with 3-OSP-045.1 and 3-OSP-045.2 for ASME Class 1 and 2 components. The inspections for both class I and 2 components consisted of all normally insulated bolted connections.
The class 2 items were also limited to only those components located inside the containment. The insulation was removed for inspection. The inspections identified two bolted connections that had evidence of leakage. They are listed below with the corresponding condition report number. All leakage was evaluated by engineering as required by ASME Xl.
Component Condition Report Number Code Class CV-3-31 OA CR 2004-9269 1
3-885 CR 2004-9586 2
Page 8 of 8