VPN-006-200, Transmittal of PGE-1065-2004, Trojan Nuclear Plant Annual Radioactive Effluent Release Report for 2004
| ML050610678 | |
| Person / Time | |
|---|---|
| Site: | Trojan File:Portland General Electric icon.png |
| Issue date: | 02/25/2005 |
| From: | Quennoz S Portland General Electric Co |
| To: | Document Control Desk, NRC/FSME |
| References | |
| +sispmjr200507, PGE-8010, VPN-006-2005 PGE-1065-2004 | |
| Download: ML050610678 (107) | |
Text
1/oNk
/P Portland General Electric Company Trojan Nuclear Plant 71760 Columbia River Hwy Rainier, OR 97048 (503) 556-3713 February 25, 2005 VPN-006-2005 Trojan Nuclear Plant Docket 50-344 License No. NPF-1 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 PGE-1065-2004. "Trojan Nuclear Plant Annual Radioactive Effluent Release Report for 2004" In accordance with 10 CFR 50.36a and PGE-8010, Trojan Nuclear Plant Quality Assurance Program, Appendix C, Section 1.5.1.3, the enclosure to this letter is Portland General Electric Company's Trojan Nuclear Plant Annual Radioactive Effluent Release Report for 2004. If there are any questions concerning this report, please contact Mr. Jerry Reid at (503) 556-6474.
Sincerely, Stephen M. Quennoz Vice President, Generation Enclosure c:
Director, NRC Region IV, DNMS J. T. Buckley, NRC, NMSS, DWM D. Stewart-Smith, ODOE A. Bless, ODOE
~'S8 P () 5sD Connecting People, Power and Possibilities
PGE-1065-2004 Trojan Nuclear Plant Annual Radioactive Effluent Release Report for 2004 PORTLAND GENERAL ELECTRIC COMPANY
PGE-1065-2004 TROJAN NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2004 Docket 50-344 License No. NPF-1 PORTLAND GENERAL ELECTRIC COMPANY 121 S. W. Salmon Street Portland, Oregon 97204
TROJAN NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2004 TABLE OF CONTENTS SECTION TITLE PAGE TABLE OF CONTENTS.................................................
i
SUMMARY
I
- 1.
EFFLUENT AND WASTE DISPOSAL REPORT.......................................
4
- 2.
OFFSITE RADIATION DOSES.................................................
23
- 3.
METEOROLOGICAL DATA.................
90
- 4.
CHANGES TO THE OFFSITE DOSE CALCULATION MANUAL.........
91
- 5.
ASSESSMENT OF DOSES WiTHIN THE UNRESTRICTED AREA BOUNDARY........................................
92
- 6.
DIRECT RADIATION DOSES FROM THE FACILITY.............................. 94 ATTACHMENT 1, SOLID WASTE SHIPPED OFFSITE FOR DISPOSAL AND ESTIMATES OF MAJOR NUCLIDES BY WASTE CLASS AND STREAM FROM JANUARY 1, 2004 TO DECEMBER 30, 2004 i
SUMMARY
The Trojan Nuclear Plant Annual Radioactive Effluent Release Report for 2004 is submitted in accordance with 10 CFR 50.36a, and PGE-8010, Trojan Nuclear Plant Quality Assurance Program, Appendix C, Section 1.5.1.3. The report is divided into six sections: (1) effluent and waste disposal report; (2) offsite radiation doses; (3) meteorological data; (4) changes to the Offsite Dose Calculation Manual (ODCM); (5) assessment of doses within the unrestricted area boundary; and (6) direct radiation doses from the facility.
Requirement PGE-8010, Trojan Nuclear Plant Quality Assurance Program, Appendix C, Section 1.5.1.3, "Annual Radioactive Effluent Release Report," requires:
The Annual Radioactive Effluent Release Report covering the activities of the unit shall be submitted in accordance with 10 CFR 50.36a. The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit. The material provided shall be consistent with the objectives outlined in the ODCM and Process Control Program.
Offsite Dose Calculation Manual, Control 3.1.2 requires:
The radioactive gaseous effluent sampling equipment channels...shall be OPERABLE to ensure that the limits of Control 3.2.2.1 are not exceeded.
... With the inoperable channels not returned to OPERABLE status within 30 days, identify the cause of the inoperable channels in the annual Radioactive Effluent Release Report in lieu of any other report.
Offsite Dose Calculation Manual, Control 4.1.2 requires:
The Annual Radioactive Effluent Release Report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit as outlined in Regulatory Guide 1.21 (Rev. 1), 'Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous EJfluents from Light-Water-Cooled Nuclear Power Plants, "with data summarized on a quarterly basis following the format of Appendix B thereof:
The Annual Radioactive Effluent Release Report shall include an assessment of the radiation doses front radioactive effluents to MEMBERS OF THE PUBLIC dlue to their activities in UNRESTRICTED AREAS during the report period. All assumptions used in making these assessmenlts (e.g., specific activity, exposure time and location) shall be included in these reports.
1
The Annual Radioactive Effluent Release Report shall include a copy of all licensee event reports required by 10 CFR 50.73(a)(2)(viii).
The Annual Radioactive Effluent Release Report shall include an assessment of radiation doses from the radioactive liquid and gaseous effluents released from the unit as outlined in Regulatory Guide 1.21. Exceptions to Regulatory Guide 1.21 are documented in Table 1-1 of PGE-1061, Trojan Nuclear Plant Defueled Safety Analysis Report and License Termination Plan (PGE-1078). The assessment of radiation doses shall be performed in accordance with Sections S and 6 of the ODCM.
10 CFR 50.36a(a)(2) requires:
Each licensee shall submit a report to the Commission annually that specifies the quantity of each of the principal radionuclides released to unrestricted areas in liquid and in gaseous effluents during the previous 12 months, including any other information as may be required by the Commission to estimate maximum potential annual radiation doses to the public resulting from effluent releases. The report must be submitted as specified in §50.4, and the time between submission of the reports must be no longer than 12 months. If quantities of radioactive materials released during the reporting period are significantly above design objectives, the report must cover this specifically. On the basis of these reports and any additional information the Commission may obtain from the licensee or others, the Commission may require the licensee to take action as the Commission deems appropriate.
Report Data for the period January 1, 2004, through December 31, 2004, have been included.
No licensee event reports required by 10 CFR 50.73(a)(2)(viii) were submitted during 2004.
Gaseous effluents are summarized in Tables 1-6, 1-8, 1-9, and 1-10. The control limits for gaseous effluents are found in Table 1-1. Effluent concentration values for gaseous effluents are not used in effluent calculations at Trojan. Measurement methods and errors associated with the measurements for gaseous effluents are found in Tables 1-5 and 1-7, respectively. Gaseous effluent lower levels of detection are found in Table 1-11.
Liquid effluents are summarized in Tables 1-6 and 1-12 and 1-13. The control limits for liquid effluents are found in Table 1-3 and the effluent concentration values for liquid effluents are found in Table 1-4. Measurement methods and errors associated with the measurements for liquid effluents are found in Tables 1-5 and 1-7, respectively. Liquid effluent lower levels of detection are found in Table 1-14.
Solid waste and irradiated fuel shipments are listed in Table 1-15.
2
Offsite radiation doses from liquid effluents are listed in Tables 2-3 and 2-4 through 2-7.
Parameters used to calculate offsite doses are found in Table 2-2.
Offsite radiation doses from gaseous effluents are listed in Tables 2-8 through 2-58. Parameters used to caluculate offsite doses are found in Table 2-1. Population doses from gaseous effluents are summarized by pathway in Tables 2-59 through 2-62.
The calculation assumptions for onsite radiation doses are presented in Table 5-1 and onsite radiation doses are listed in Table 5-2 and Section 6.
3
- 1. EFFLUENT AND WASTE DISPOSAL REPORT This section contains a summary of the liquid and gaseous release limits; a list of the effluent concentration values of the nuclides released; a summary of batch and abnormal release data; a summary of total liquid and gaseous releases; listings of nuclides released classified by pathway, gaseous or liquid, and type, continuous or batch; and a summary of solid radioactive waste shipments.
This section represents releases during the period January 1, 2004, through December 31, 2004. The information for January 1, 2004, through December 31, 2004, is presented in Tables 1-1 through 1-15.
The "MDA" notation used in the following data tables indicates that no detectable activity was found when samples were analyzed using counting techniques which ensure compliance with the "Lower Limit of Detection" (LD) values of ODCM Tables 3.2.1.1-1 and 3.2.2.1-1. The referenced LLD specifications are not used as limiting values for reporting activity; all measurable activity is reported.
Gamma emitting nuclides, nuclides with measurable activity, together with those nuclides specified in ODCM Tables 3.2.1.1-1 and 3.2.2.1-1 are reported.
Liquids There were 26 discharges with no abnormal releases during 2004. The last liquid discharge from the site was on October 7, 2004.
Gaseous The requirement to monitor gaseous releases using PRM-2 was removed from the ODCM with Amendment 23 (ref. SMQ-006-2003, S. M. Quennoz, Portland General Electric Company, to D. Stewart-Smith, Oregon Department of Energy, dated September 4, 2003). There is no longer a source of radioactive noble gases in the Auxiliary/Fuel Building since the spent fuel was transferred to the ISFSI. The remaining monitoring of tritium and particulates is via manual samples taken as currently required by the ODCM. Exhaust from the Auxiliary/Fuel Building was secured on October 7, 2004.
No unplanned gaseous releases occurred during 2004.
The following term is used:
Ri=
Average dose factor for radionuclides in particulate form (gaseous effluents) at the controlling exposure locations 4
TABLE 1-1 SUPPLEMENTAL INFORMATION January 1, 2004, through December 31, 2004 CONTROL LIMITS Fission and Activation Gas Release Rate Limits First Unit Quarter' Second Quarter' Third Quarter' Fourth Quarter'
- 1. ODCM 3.2.2.1, Instantaneous 2.0Kv QV <
1
- 2. 0C33(LV Q
ly Nve
- 2. ODCM 3.2.2.2, Quarterly Average Ci/sec N/A Ci/sec N/A N/A N/A N/A N/A N/A N/A QTV <
I 50Nv 1
QTV 25Mv
- 3. ODCM 3.2.2.4, Quarterly Average Requiring Use of the Gaseous Radwaste Treatment System Ci/sec N/A Ci/sec N/A N/A N/A N/A N/A N/A N/A QTV <
1 100Nv QTV <
50MV Ci/sec N/A Ci/sec N/A N/A N/A N/A N/A N/A N/A
'Control limits for fission and activiation gaseous releases no longer apply. See ODCM Amendment 23.
5
TABLE 1-2 SUPPLEMENTAL INFORMATION January 1, 2004, through December 31, 2004 CONTROL LIMITS Gaseous Tritium. and Particulates With > 8 Day TL/2 Limits First Unit Quarter Second Quarter Third Ouarter Fourth Quarter
- 1.
ODCM 3.2.2.1, Instantaneous QVO<-_
1 0.67%
Ci/sec 1.61E-8 1.61E-8 2.17E-8 1.61E-8
- 2.
ODCM 3.2.2.3, Quarterly Average Qv <-1 100Ri Ci/sec 1.08E-10 1.08E-10 1.45E-10 1.08E-10
- 3.
ODCM 3.2.2.4, Quarterly Average Requiring Use of the Ventilation Exhaust Treatment System 200Ri Ci/sec 5.40E-11 5.40E-I 7.26E-1I 5.40E-11 6
TABLE 1-3 SUPPLEMENTAL INFORMATION January 1, 2004, through December 31, 2004 CONTROL LIMITS
- 1.
ODCM 3.2.1.1 Instantaneous
- 2.
ODCM 3.2.1.2 Quarterly Average
- 3.
ODCM 3.2.1.3 Quarterly Average Requiring Use of the Liquid Radwaste Treatment System
- 4.
Tech. Spec. 5.7.2.61 Storage Tank Radioactivity Limit Instantaneous discharge concentrations less than the effluent concentration values (ECVs) listed in 10 CFR Part 20, Appendix B, Table 2, Column 2.
Gross release limit of 2.5 Ci per quarter excluding tntium and dissolved noble gases. If this limit is exceeded, cumulative dose due to liquid effluents will be limited to 1.5 mrem to the whole body and to 2.5 mrem to any organ, using isotope specific methodology in the Plant Offsite Dose Calculation Manual (ODCM).
The liquid radwaste treatment system shall be maintained and used when activity discharged (excluding tritium and dissolved noble gases) would exceed 1.25 Ci/Qtr.
..the quantity of radioactivity contained in all outdoor liquid radwaste tanks that are not surrounded by liners, dikes, or walls capable of holding the tanks' contents and that do not have tank overflows and surrounding area drains connected to the liquid radwaste treatment system is less than limits of 10 CFR 20, Appendix B at the nearest potable water supply and the nearest surface water supply in an unrestricted area, in the event of an uncontrolled release of the tanks' contents. For temporary storage tanks a limit of 10 curies, excluding tritium and dissolved or entrained noble gases, may be used...
' This Tech. Spec. limit was relocated from the Ol)CM to PGE-8010. Nuclear Quality Assurance Program, Appendix C, Section 1.4.2.6, in Revision 26 to PGE-8010.
7
TABLE 1-4 SUPPLEMENTAL INFORMATION January 1, 2004, through December 31, 2004 EFFLUENT CONCENTRATION VALUES (ECVs)
Liquid (10 CFR 20, Appendix B, Table 2, Col. 2)
Isotope Tritium Iron 55 Cobalt 57 Cobalt 60 Strontium 90 Niobium 94 Antimony 125 ECV (ucilcc) 1 x 10-3 1 x 10-4 6x 10-5 3x 10-6 5x 10-7 1 x 10-5 3 x 10-5 Isotope Cesium 134 Cesium 137 Cerium 144 Europium 152 Europium 154 Europium 155 Americium 241 Alpha ECV (uCi/cc) 9 x 10-7 1 x 10-6 3 x 10-6 1 x 10-5 7 x 10-6 5 x 10-5 2 x 10-8 2x 10-9 Gaseous Gaseous ECVs are not used in effluent calculations at Trojan.
8
TABLE 1-5 SUPPLEMENTAL INFORMATION January 1, 2004, through December 31, 2004 AVERAGE ENERGY Effluent release limits are not based upon E, hence, reporting E is not required.
MEASUREMENTS AND APPROXIMATIONS OF TOTAL RADIOACTIVITY Gaseous Releases Particulates: Composite filter samples are analyzed by gamma spectroscopy to determine the concentration of particulate isotopes. Composite samples are analyzed for alpha-emitting isotopes by counting with a gas flow proportional counter.
Liquid Releases Fission and Activation Products: Gamma spectrometric analysis of each batch is performed. Monthly and quarterly composites are prepared for batch releases for specified activity determinations.
Tritium: Samples from each batch are distilled and deionized as necessary to remove contamination and counted by liquid scintillation techniques.
Dissolved and Entrained Gases: There are no longer any dissolved or entrained gases in the liquid releases at Trojan.
9
TABLE 1-6 SUPPLEMENTAL INFORMATION January 1, 2004, through December 31, 2004 BATCH RELEASES Unit 1-1-04 to 6-30-04 Liquid Gaseous 15 0
7-1-04 to 12-31-04 Liquid Gaseous 11 0
Number of Batch Releases Total time period for Batch Releases Maximum time period for Batch Releases Average time period for Batch Releases Minimum time period for Batch Releases Average dilution flow during Batch Releases ABNORMAL RELEASES Number of Abnormal Releases Total Activity Released Hours Hours Hours Hours GPM Ci 5.1 0.9 0.3 0.2 3844 0
0 NA NA NA NA NA 0
0 10.9 2.3 1.0 0.2 0
0 0
NA NA NA NA NA 0
0 10
TABLE 1-7 SUPPLEMENTAL INFORMATION January 1, 2004 through December 31, 2004 ESTIMATION OF TOTAL PERCENT ERROR The estimated total error is calculated as follows:
Total Percent Error-El + E2+ E3 +.. En )
Where En = Percent error associated with each contributing parameter.
The following values (percent) were used for error calculations:
GASEOUS EFFLUENTS Particulates Sample Counting Error 25 Counting System Calibration Error 10 Counting System Source Error 5
Temperature/Volume Correction Error NA Process Flow Measuring Device 10 Sample Flow Measuring Device 10 Plateout Error 10 LIQUID EFFLUENTS Fission &
Gross Act. Products Tritium Alpha Sample Counting Error 25 25 25 Counting System Calibration Error 10 10 10 Counting System Source Error 5
5 5
Process Flow Measuring Device 10 10 10 Sample Flow Measuring Device 10 10 10 11
r r
r r
rr r
I r
r r
TABLE 1-8 Sheet I of 2 GASEOUS EFFLUENTS SUMMATION OF RELEASES January 1, 2004, through December 31, 2004 First Second Third Fourth Estimated Unit Ouarter' Quarterl Quarterl Quarter' Error (%)
FISSION AND ACTIVATION GASES Total Activity Released Ci N/A N/A N/A N/A N/A Average Release Rate for Quarter jACi/sec N/A N/A N/A N/A Percent of Limit:
ODCM 3.2.2.1.a - Instantaneous N/A N/A N/A N/A ODCM 3.2.2.2.a - Quarterly Average N/A N/A N/A N/A ODCM 3.2.2.4.a - Quarterly Average Requiring Processing N/A N/A N/A N/A PARTICULATES Total with Half-lives >8 days Ci MDA MDA 1.98E-11 1.34E-11
+3.2E+1 Average Release Rate for Quarter uCi/sec N/A N/A 1.49E-1 1 4.03E-I Total Gross Alpha Released Ci MDA MDA MDA MDA
'ODCM Control Limits for fission and activiation gaseous releases no longer apply. Limits were deleted in Amendment 23.
12
r r
r r r
r r
r r
r r
r r
r TABLE 1-8 Sheet 2 of 2 GASEOUS EFFLUENTS SUMMATION OF RELEASES January 1, 2004, through December 31, 2004 First Ouarter Second Quarter Third Ouarter Fourth Ouarter Estimated Error (%)
Unit TRITIUM Total Released Average Release Rate for Quarter Ci N/A N/A N/A N/A N/A N/A N/A N/A pCi/sec N/A PARTICULATES WITH
> 8 DAY T1/2 Total Released Average Release Rate for Quarter Ci MDA N/A MDA N/A 1.98E-11 1.49E-1 I 1.34E-1 1
+3.2E+1 pCi/sec 4.03E-1 1 Percent of Limit:
ODCM 3.2.2.1 Instantaneous 0.OOE+O 0.00E+0 6.88E-8 2.50E-7 ODCM 3.2.2.3 Quarterly Average ODCM 3.2.2.4 Quarterly Average Requiring Processing 0.OOE+0 0.00E+0 0.OOE+0 0.OOE+0 1.03E-5 2.05E-5 3.73E-5 7.46E-5 13
r r
r I
r r
r r
r I
r f I
I r
(
r TABLE 1-9 Sheet I of 2 GASEOUS EFFLUENTS GROUND LEVEL RELEASES January 1, 2004, through December 31, 2004 NUCLIDES RELEASED First Quarter Continuous Mode2 Second Third Quarter Quarter Batch Model Fourth Quarter Fission Gases Unit Krypton 85 TOTAL FOR QUARTER Ci Ci 0.OOE+0 0.OOE+0 0.OOE+0 0.OOE+0 0.OOE+0 0.00E-i-0.OOE+0 0.OOE+0 N/A N/A I Information is for all four quarters of 2004.
2 Fibjion gases were not released in 2004. Spent fuel was moved to the ISFSI in 2003.
14
I r
r r
(
C r I I r
r r
TABLE 1-9 Sheet 2 of 2 GASEOUS EFFLUENTS GROUND LEVEL RELEASES January 1, 2004, through December 31, 2004 NUCLIDES RELEASED Continuous Mode Batch Mode' First Second Third Fourth ParticulaCes > 8 Day T1/2 Unit Quarter Ouarter Ouarter Quarter Manganese 54 Ci MDA MDA MDA MDA N/A Cobalt 57 Ci MDA MDA MDA MDA N/A Cobalt 60 Ci MDA MDA MDA MDA N/A Strontium 90 Ci MDA MDA 1.43E-11 1.34E-11 N/A Cesium 134 Ci MDA MDA MDA MDA N/A Cesium 137 Ci MDA MDA 5.49E-12 MDA N/A Cerium 144 Ci MDA MDA MDA MDA N/A TOTAL FOR QUARTER Ci MDA MDA 1.98E-11 1.34E-11 N/A Ilt,,,osliMi, o IN l0 Al Iuui quartels ul 7204.
15
TABLE 1-10 GASEOUS EFFLUENTS ELEVATED RELEASES January 1, 2004, through December 31, 2004 No Elevated Release Points 16
TABLE 1-11 GASEOUS EFFLUENTS LOWER LEVEL OF DETECTION January 1, 2004, through December 31, 2004 CONTINUOUS NUCLIDE UNIT RELEASE Cobalt 60 YuCi/ml 1.00E-11 Strontium 90 iCilml 1.00E-11 Cesium 134 UCi/ml 1.00E-1 1 Cesium 137
/Ci/ml 1.00E-1 1 Gross Alpha iCi/ml 1.00E-I 1 17
r r
r r
r r
r r r I r
r TABLE 1.12 LIQUID EFFLUENTS SUMMATION OF RELEASES January 1, 2004, through December 31, 2004 First Second Third Fourth Estimated Unit Quarter Quarter Quarter Quarter Error (%)
FISSION AND ACTIVATION PRODUCTS Total Activity Released (excluding Ci 1.12E-4 5.66E-5 2.60E-5 1.58E-6
+3.1E+1 gases, tritium, and alpha)
Average Diluted Concentration yCi/ml 5.36E-8 2.36E-8 8.93E-6' 3.11E-7' Percent of Limit ODCM 3.2.1.1 - Instantaneous 2.74E+O 8.90E-1 0.OOE+0 0.00E+0 ODCM 3.2.1.2 - Quarterly Limit 4.52E-3 2.26E-3 1.04E-3 6.32E-5 ODCM 3.2.1.3 - Quarterly Limit 9.03E-3 4.53E-3 2.08E-3 1.26E-4 Requiring Processing TRITIUM Total Released Ci 1.45E-3 9.59E-5 0.OOE+O 0.OOE+0
+3.IE+1 Average Diluted Concentration PCi/mI 6.93E-7 3.99E-8 0.OOE+0 0.OOE+0 Percent of ECV 6.93E-2 3.99E-3 0.OOE+0 0.00E+0 GROSS ALPHA RADIOACTIVITY Total Activity Released Ci 4.67E-7 0.00E+0 0.OOE+0 0.OOE+0
+3.1E+1 UNDILUTED VOLUME OF WASTE Liters 1.42E+4 6.30E+3 2.91E+3 5.08E+3
+5.0 RELEASES VOLUME OF DILUTION WATER Liters 2.10E+6 2.40E+6 0.OOE+0 0.OOE+0
+1.5E+1 1 The value is the average total activity concentration. Activity was released without dilution water.
18
I rrr r
r r
(
r r
r TABLE 1-13 LIQUID EFFLUENTS January 1, 2004, through December 31, 2004 NUCLIDES RELEASED Continuous Model Batch Mode First Second Third Fourth Unit Quarter Quarter Quarter Quarter Sodium 22 Ci N/A MDA MDA MDA MDA Iron 55 Ci N/A 4.62E-5 4.62E-5 MDA MDA Cobalt 57 Ci N/A MDA MDA 1.55E-8 MDA Cobalt 60 Ci N/A 3.02E-4 MDA 1.86E-5 1.58E-6 Strontium 90 Ci N/A 1.04E-5 1.04E-5 MDA MDA Niobium 94 Ci N/A 1.07E-6 MDA 5.55E-7 MDA Silver 108m Ci N/A MDA MDA MDA MDA Antimony 125 Ci N/A MDA MDA MDA MDA Cesium 134 Ci N/A MDA MDA 4.01E-8 MDA Cesium 137 Ci N/A 2.46E-5 6.03E-9 6.78E-6 MDA Cerium 144 Ci N/A MDA MDA MDA MDA Europium 152 Ci N/A MDA MDA MDA MDA Europium 154 Ci N/A MDA MDA MDA MDA Europium 155 Ci N/A MDA MDA MDA MDA Americium 241 Ci N/A MIDA MDA MDA MDA Unidentified Ci N/A MDA MDA MDA MDA TOTAL Ci N/A 1.12E-4 5.66E-5 2.60E-5 1.58E-6
' Information for all four quarters of 2004.
19
TABLE 1-14 LIQUID EFFLUENTS LOWER LEVEL OF DETECTION January 1, 2004, through December 31, 2004 LOWER LEVEL OF DETECTION BATCH NUCLIDE UNIT RELEASE Tritium
,uCi/m1 1.00E-5 Iron 55 yuCi/ml 1.00E-6 Cobalt 60
,uCi/ml 5.OOE-7 Strontium 90 pCi/ml 5.00E-8 Cesium 134 uCi/ml 5.OOE-7 Cesium 137
,2Ci/ml 5.OOE-7 Gross Alpha 12Ci/ml 1.00E-7 20
I I
r r
r r
r r
r r
r r
r TABLE 1-15 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Sheet 1 of 2 January 1, 2004, through December 30, 2004 SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not Irradiated Fuel) - Type of Waste Activity' During 1-1 to 6-30 Volume During 1-1 to 6-30 Activity' During 7-1 to 12-30 Volume During 7-1 to 12-30 Estimated2 Total Error (%)
- 1.
Spent Resin, Filters, Sludges, Evaporator Bottoms, etc.
4.92E-01 Ci 4.35E+00 m3 0
0 2.5E+01
- 2.
Dry Compressible Waste, Contaminated Equipment, etc.
5.11E-01 Ci 3.91E+02 m3 6.35E-02 Ci 1.34E+02 m3 2.5E+01
- 3.
Irradiated Components, Control Rods, etc.
0 0
0 0
- 4.
Other (Spent Fuel Particles & Cs-137 Sources Encapsulated) 2.68E-01 Ci 2.12E-01 m2 1.03E-01 Ci 6.37E-01 m3 2.5E+01 ESTIMATE OF MAJOR NUCLIDE DISTRIBUTION BY TYPE OF WASTE Nuclide
- 1. See lists in Attachment 1.
- 2. See lists in Attachment 1.
- 3. N/A
- 4. N/A
' Note: Activity calculations include all shipments from PGE to U.S. Ecology.
2 Basis: Instrument inaccuracies (portable and multi-channel analyzer).
21
r r
r r
I r
r r
r r
r
(
r f
r r
r TABLE 1-15 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Januarv 1. 2004. through December 30. 2004 Sheet 2 of 2 SOLID WASTE DISPOSITION Number of Shipments 18 - 1/1/2004 through 6/30/2004 5 - 7/1/2004 through 12/30/2004 IRRADIATED FUEL SHIPMENTS Number of Shipments 0
Mode of Transportation Exclusive Use Truck by Highway Exclusive Use Truck by Highway Mode of Transportation NA Destination U.S. Ecology, Inc.
P.O. Box 638 Richland, WA 99352 Destination NA 22
- 2. OFFSITE RADIATION DOSES Offsite radiation doses from gaseous and liquid effluents for 2004 are presented in this section.
Included are quarterly doses to individuals at locations of maximum exposure and quarterly doses to the 50-mnile population. Doses are presented separately for batch and continuous releases from gaseous effluents.
For gaseous effluents, doses were calculated using conservative meteorological data. The highest X/Q and D/Q values established for each receptor, from 1976 through 1994, were used to calculate population doses. All other doses due to gaseous effluents were conservatively calculated using meteorological data established for the site boundary.
23
TABLE 2-1 Sheet 1 of 2 PARAMETERS USED IN CALCULATING DOSES FROM GASEOUS EFFLUENTS FIRST AND SECOND HALVES 2004 Parameter Value Accumulation and Decay Times (days)
Harvest of leafy vegetables to consumption by man 1.0 Harvest of pasture grass to consumption by animals 0.0 Harvest of stored feed to consumption by animals 90.0 Harvest of produce to consumption by man 60.0 Animal butchering to consumption 20.0 Food ingestion by animal to milking 2.0 Accumulation time on ground 5,480.0 Human Consumption Rates (kglyr)
Leafy vegetables by adult 64.0 Produce by adult 456.0 Meat by adult 110.0 Milk by adult 310.0 Milk by infant 330.0 Breathing Rates (m3/yr)
Adult 8,000.0 Infant 1,400.0 Animal Consumption Rates (kg/day)
Animal feed by meat animal 50.0 Animal feed by milk cow 50.0 Animal feed by milk goat 6.0 Exposure Periods During Growing Season (days)
Leafy vegetables 60.0 Pasture vegetation 30.0 Produce 60.0 Residential Structure Shielding Factor 0.7 Fraction of Particulates Initially Deposited on Leafy Vegetation 0.2 Fraction of Particulates Initially Deposited on Produce 0.2 24
TABLE 2-1 Sheet 2 of 2 PARAMETERS USED IN CALCULATING DOSES FROM GASEOUS EFFLUENTS Parameter Value Fraction of Iodine Deposited on Leafy Vegetation 1.0 Fraction of Iodine Deposited on Produce 1.0 Surface Density of Soil for Root Zone (kg/rm2) 240.0 Field Decay Half life (days) 14.0 Agricultural Productivity (kg/M2)
Leafy vegetables 2.0 Pasture grass 0.7 Produce 2.0 Period of Long-Term Buildup for Activity in Soil (days) 5,480.0 Fraction of Leafy Vegetables Grown in Garden of Interest 1.0 Fraction of Produce Grown in Garden of Interest 1.0 Fraction of Year Animal Grazes on Pasture 0.5 Fraction of Daily Feed that is Pasture Grass when Animal Grazes 1.0 25
TABLE 2-2 Sheet 1 of 3 PARAMETERS USED IN CALCULATING DOSES FROM LIQUID EFFLUENTS Value First Ouarter 2004 Second Third Quarter 2004 Quarter 2004 Fourth Quarter 2004 Parameter Plant Dilution Flow Rate (gpm)
Columbia River Flow Rate (cfs) 45 13 0
0 176,020 217,177 138,051 148,437 Dilution Factors Drinking water Swimming water Aquatic biota Shoreline sediment Irrigation water Milk and meat animal water 1,760,200 387,244 387,244 387,244 1,760,200 1,760,200 7,239,233 1,592,631 1,592,631 1,592,631 7,239,233 7,239,233 13,805,100 3,037,122 3,037,122 3,037,122 13,805,100 13,805,100 14,843,700 3,265,614 3,265,614 3,265,614 14,843,700 14,843,700 Decay Times (days)
Discharge to drinking water 0.70 Discharge to swimming water 0.0 Discharge to aquatic biota consumption 1.0 Discharge to deposition on shoreline sediment 0.0 Discharge to irrigation water withdrawal 0.70 Discharge to milk and meat animal water withdrawal 0.70 Leafy vegetable harvest to consumption by man 1
0.66 0.0 1.0 0.0 0.66 0.66 1
60 90 0.75 0.0 1.0 0.73 0.0 1.0 0.0 0.0 0.75 0.75 0.73 0.73 1
1 Produce harvest to consumption by man Stored feed harvest to consumption by animals Pasture grass to consumption by animals Animal butchering to consumption Food and water ingestion by cow/goat to milking 60 90 0
20 2
60 60 90 90 0
20 0
20 0
20 2
2 2
26
TABLE 2-2 Sheet 2 of 3 PARAMETERS USED IN CALCULATING DOSES FROM LIQUID EFFLUENTS Value First Second Third Fourth Parameter Quarter 2004 Quarter 2004 Quarter 2004 Quarter 2004 Accumulation Times (days)
Shoreline sediment 5,480 5,480 5,480 5,480 Irrigated soil 5,480 5,480 5,480 5,480 Irrigated vegetables 60 60 60 60 Pasture grass 30 30 30 30 Adult Consumption Rates (kglyr)
Drinking water 730 730 730 730 Fish 21 21 21 21 Invertebrates (crayfish) 5 5
5 5
Irrigated leafy vegetables 64 64 64 64 Irrigated produce 456 456 456 456 Cow's milk from irrigated pastureland 310 310 310 310 Goat's milk from irrigated pastureland310 310 310 310 Meat from irrigated pastureland 110 110 110 110 Annual Exposure Times (hr/yr)
Swimming and boating 12 12 12 12 Shoreline activities 12 12 12 12 Irrigated pasture 2,190 2,190 2,190 2,190 Infant Consumption Rates (kg/yr)
Drinking water 330 330 330 330 Cow's milk from irrigated pastureland 330 330 330 330 Fraction of Year Animals Graze on Pasture 0.5 0.5 0.5 0.5 Fraction of Year Crops are Irrigated 0.5 0.5 0.5 0.5 Field (Weathering) Half-Life (days) 14 14 14 14 Irrigation Rate (liters/m2-hr) 0.104 0.104 0.104 0.104 Fractional Concentration of Water in Soil (g/g) 0.2 0.2 0.2 0.2 27
TABLE 2-2 Sheet 3 of 3 PARAMETERS USED IN CALCULATING DOSES FROM LIQUID EFFLUENTS Value First Parameter Ouarter 2004 Fraction of Leafy Vegetables Grown 1
in Garden of Interest Second Ouarter 2004 1
Third Ouarter 2004 1
Fourth Ouarter 2004 1
Fraction of Produce Grown in Garden of Interest Irrigated Soil Self-Shielding Factor Fraction of Isotope in Irrigation Water That is Initially Retained by Leafy Vegetables Fraction of Isotope in Irrigation Water That is Initially Retained by Produce Pasture Grass Yield (kglm2)
Vegetable Yield (kg/m2)
Surface Density of Soil (kg/m2)
Animal Consumption Rates (kg/day)
Water by milk cow Water by milk goat Water by beef Pasture vegetation by milk cow Pasture vegetation by milk goat Pasture vegetation by beef 0.7 2.5 0.25 0.25 0.7 2
240 60 8
50 50 6
50 0.7 2.5 0.25 0.25 0.7 2
240 60 8
50 50 6
50 0.7 0.7 2.5 2.5 0.25 0.25 0.25 0.25 0.7 0.7 2
2 240 240 60 8
50 50 6
50 60 8
50 50 6
50 28
TABLE 2-3 Page 1 of 2
SUMMARY
OF DOSES RESULTING FROM RADIOACTIVE RELEASES IN LIQUID WASTES (MREM/YR) [MAXIMUM COMBINATION OF PATHWAYS:
AQUATIC PLUS IRRIGATION (GOAT OR COW MILK CONSUMPTION)]
2004 FIRST OUARTER 2004 AGE WHOLE GROUP BODY ADULT 4.41E-5 TEEN 3.07E-5 CHILD 2.46E-5 INFANT 4.13E-6 SKIN 4.42E-5 3.08E-5 2.46E-5 4.13E-6 SECOND QUARTER 2004 AGE WHOLE GROUP BODY SKIN ADULT 1.07E-6 1.07E-6 TEEN 1.02E-6 1.02E-6 CHILD 1.38E-6 1.38E-6 INFANT 2.76E-7 2.76E-7 BONE 8.90E-5 8.98E-5 1.18E-4 2.13E-5 BONE 4.37E-6 4.16E-6 5.48E-6 1.08E-6 GI TRACT 1.92E-5 1.44E-5 5.67E-6 2.76E-7 GI TRACT 1.52E-7 1.38E-7 8.28E-8 1.39E-8 THYROID 3.66E-7 5.89E-7 1.61E-7 4.11E-8 THYROID 1.50E-10 1.40E-10 2.28E-10 2.20E-10 LUNG 5.94E-6 7.56E-6 6.18E-6 1.06E-6 LUNG 2.66E-8 3.28E-8 3.10E-8 1.15E-9 KIDNEY 1.66E-5 1.78E-5 1.61E-5 2.55E-6 KIDNEY 4.64E-10 4.76E-10 5.40E-10 2.70E-10 LIVER 4.77E-5 5.12E-5 4.92E-5 9.54E-6 LIVER 4.96E-8 5.34E-8 5.71E-8 2.04E-8 29
TABLE 2-3 Page 2 of 2
SUMMARY
OF DOSES RESULTING FROM RADIOACTIVE RELEASES IN LIQUID WASTES (MREM/YR) [MAXIMUM COMBINATION OF PATHWAYS:
AQUATIC PLUS IRRIGATION (GOAT OR COW MILK CONSUMPTION)]
THIRD QUARTER 2004 AGE WHOLE GROUP BODY SKIN ADULT 1.19E-6 1.12E-6 TEEN 6.66E-7 6.72E-7 CHILD 2.78E-7 2.79E-7 INFANT 2.61E-8 2.61E-8 FOURTH QUARTER 2004 AGE WHOLE GROUP BODY SKIN ADULT 2.43E-9 2.70E-9 TEEN 3.52E-9 3.94E-9 CHILD 1.95E-9 2.04E-9 INFANT 2.75E-10 2.75E-10 BONE 1.23E-6 1.36E-6 1.79E-6 2.82E-7 BONE 1.5 lE-9 2.53E-9 5.27E-10 0.OOE+0 GI TRACT 1.13E-6 8.27E-7 3.OOE-7 4.08E-9 GI TRACT 9.34E-9 8.29E-9 3.19E-9 2.77E-10 THYROID 2.25E-8 3.75E-8 7.83E-9 0.00E+0 THYROID 1.51E-9 2.53E-9 5.27E-10 0.00E+0 LUNG
- 2. 10E-7 2.71E-7 2.09E-7 3.58E-8 LUNG 1.51E-9 2.53E-9 5.27E-10 0.00E+0 KIDNEY 5.83E-7 6.37E-7 5.64E-7 8.85E-8 KIDNEY 1.511E-9 2.53E-9 5.27E-10 0.OOE+0 LIVER 1.68E-6 1.80E-6 1.72E-6 3.31E-7 LIVER 1.93E-9 2.96E-9 1.01E-9 1.16E-10 30
r r
r r
r r
r r
I r I
r r
I r
r r
TABLE 2-4 FIRST QUARTER 2004 POPULATION DOSE (50-MILE) FROM LIQUID EFFLUENTS (MAN-REM)
EXPOSURE PATHWAY TOTAL BODY THYROID AQUATIC DRINKING WATER 4.OE-06 2.8E-08 FISH CONSUMPTION 2.4E-03 7.9E-08 INVERTEBRATE CONSUMPTION 2.4E-06 8.7E-11 EXPOSURE TO CONTAMINATED SEDIMENT 4.1E-07 4.1E-07 SWIMMING AND BOATING 1.5E-09 1.SE-09 IRRIGATION AND LIVESTOCK WATERING LEAFY VEGETABLE CONSUMPTION 4.2E-08 4.8E-11 PRODUCE CONSUMPTION 2.1E-07 2.4E-10 MEAT CONSUMPTION 1.6E-07 1.8E-09 MILK CONSUMPTION 2.8E-06 1.7E-08 EXPOSURE TO CONTAMINATED SOIL 3.4E-08 3.4E-08 TOTAL 2.4E-03 5.7E-07 AVERAGE DOSE (MREM/PERSON) 1.2E-06 2.8E-10 31
r f
r II r
r r
[
[
(
(
[
r r
r F r
TABLE 2-5 SECOND QUARTER 2004 POPULATION DOSE (50-MILE) PROM LIQUID EFFLUENTS (MAN-REM)
EXPOSURE PATHWAY TOTAL BODY THYROID AQUATIC DRINKING WATER 2.9E-07 1.5E-10 FISH CONSUMPTION 2.7E-O5 4.2E-10 INVERTEBRATE CONSUMPTION 1.OE-07 4.7E-13 EXPOSURE TO CONTAMINATED SEDIMENT 2.3E-12 2.3E-12 SWIMMING AND BOATING 1.2E-13 1.2E-13 IRRIGATION AND LIVESTOCK WATERING LEAFY VEGETABLE CONSUMPTION 3.1E-09 2.6E-13 PRODUCE CONSUMPTION l.5E-08 1.3E-12 MEAT CONSUMPTION 7.3E-09 9.5E-12 MILK CONSUMPTION 9.7E-00 9.4E-ll EXPOSURE TO CONTAMINATED SOIL 1.9E-13 1.9E-13 TOTAL 2.8E-05 6.9E-10 AVERAGE DOSE (MREM/PERSON) 1.4E-08 3.3E-13 32
r r
[
r r
r r
r r
r r
I r
r r
r TABLE 2-6 THIRD QUARTER 2004 POPULATION DOSE (50-MILE) FROM LIQUID EFFLUENTS (MAN-REM)
EXPOSURE PATHWAY TOTAL BODY THYROID AQUATIC DRINKING WATER 1.4E-08 0.0E+00 FISH CONSUMPTION 7.2E-05 O.OE+00 INVERTEBRATE CONSUMPTION 4.1E-08 0.OE+00 EXPOSURE TO CONTAMINATED SEDIMENT 2.7E-08 2.7E-08 SWIMMING AND BOATING 1.2E-10 1.2E-10 IRRIGATION AND LIVESTOCK WATERING LEAFY VEGETABLE CONSUMPTION 1.4E-10 O.OE00 PRODUCE CONSUMPTION 7.OE-10 0.OE+00 MEAT CONSUMPTION 2.8E-09 0.OE+00 MILK CONSUMPTION 5.8E-08 0.OE+00 EXPOSURE TO CONTAMINATED SOIL 2.3E-09 2.3E-09 TOTAL 7.2E-05 2.9E-08 AVERAGE DOSE (MREM/PERSON) 3.SE-08 1.4E-11 33
r r
r r
r r
r
(
[
r r
r r
r TABLE 2-7 FOURTH QUARTER 2004 POPULATION DOSE (50-MILE) FROM LIQUID EFFLUENTS (MAN-REM)
EXPOSURE PATHWAY TOTAL BODY THYROID AQUATIC DRINKING WATER 1.6E-10 0.0E+00 FISH CONSUMPTION 2.6E-08 0.OE+00 INVERTEBRATE CONSUMPTION 1.1E-10 0.0E+00 EXPOSURE TO CONTAMINATED SEDIMENT 1.8E-09 1.8E-09 SWIMMING AND BOATING 8.9E-12 8.9E-12 IRRIGATION AND LIVESTOCK WATERING LEAFY VEGETABLE CONSUMPTION 1.7E-12 0.0E+00 PRODUCE CONSUMPTION 8.1E-12 0.OE+00 MEAT CONSUMPTION 8.1E-11 0.OE+00 MILK CONSUMPTION 6.6E-11 0.OE+00 EXPOSURE TO CONTAMINATED SOIL 1.5E-10 1.5E-10 TOTAL 2.8E-08 2.OE-09 AVERAGE DOSE (MREM/PERSON) 1.4E-11 9.6E-13 34
TABLE 2-8 BATCH RELEASES FIRST, SECOND, THIRD, AND FOURTH QUARTERS 2004 DOSES FROM NOBLE GASES AT SITE BOUNDARY AND RESIDENCE OF HIGHEST CONCENTRATION Site Boundagr[a]
Residence[bl Beta Air Dose (mrad) 0.OOE+00 O.OOE+00 Gamma Air Dose (mrad)
O.OOE-00 0.OOE+00 Beta + Gamma Skin Dose (mrem) 0.OOE+00 Gamma Total Body Dose (mrem) 0.OOE+00
[a] All Sectors
[b] All Sectors 35
I.-
TABLE 2-9 CONTINUOUS RELEASES FIRST, SECOND, THIRD, AND FOURTH QUARTERS 2004 DOSES FROM NOBLE GASES AT SITE BOUNDARY AND RESIDENCE OF HIGHEST CONCENTRATION Site Bound Ev[a]
Beta Air Dose (mrad)
Gamma Air Dose (mrad)
Beta + Gamma Skin Dose (mrem)
Gamma Total Body Dose (mrem) 0.OOE+00 0.OOE+00 Residence[b]
0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00
[a] All Sectors
[b] All Sectors 36
TABLE 2-10 BATCH + CONTINUOUS RELEASES FIRST, SECOND, THIRD, AND FOURTH QUARTERS 2004 DOSES FROM NOBLE GASES AT SITE BOUNDARY AND RESIDENCE OF HIGHEST CONCENTRATION Site Boundary[a]
Residence[b]
Beta Air Dose (mrad) 0.OOE+00 0.OOE+00 Gamma Air Dose (mrad) 0.OOE+00 0.OOE+00 Beta + Gamma Skin Dose (mrem) 0.OOE+00 Gamma Total Body Dose (mrem)
-0.OOE+00
[a] All Sectors
[b] All Sectors 37
r r
r r
r r
r r
r F
F r
r r
TABLE 2-11
- 1 QUARTER 2004 BATCH RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.ooe+00 o.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.003+00 TOTAL 0.00E+00 0,OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.ooe+00 o.OOE+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00B+00 0.00E+00 0.00E+00 0.00E+00
-TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.003+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00+E00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.003+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 38
f r~
t r
r I
f r r
I I
[
r[
I TABLE 2-12
- 1 QUARTER 2004 CONTINUOUS RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES)
AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.ooe+00 0.000+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.008+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.OOE+00 0.00B+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 MEAT CONSUMPTION 0.00E+00 0.OOE+00 0.002+00 0.00E+00 0.OOE+00 0.00R+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.002+00 0.OOE+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00B+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.002+00 0.00E+00 0.00E+00 0.00+E00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00o+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.002+00 0.00E+00 0.002+00 0.00E+00 0.00E+00 0.002+00 0.002+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.002+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 39
r I r f
r I
r r
I r
I
[
r.
r TABLE 2-13
- 1 QUARTER 2004 BATCH + CONTINUOUS RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS:
(MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.00E+00 o.OOE+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00 0.00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 o.OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00 TOTAL MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00
- 0. OOE+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.OOE+00
- 0. OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.OOE+00-
- 0. OOE+00
- 0. OOE+00 0.00E+00
- 0. 00E+00 0.00E+00 0.OOE+00 o.OOE+00 0.00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.OOE+00 TOTAL 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MILK COW MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION 0.00E+00 0.0 0E+00 0.OOE+00
- o. OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00 0.0 0E+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00 0.OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.OOE+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00 TOTAL 0.00E+00 0.00E+00 0.OOE+00 0.60E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MILK GOAT MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.001+00 0.00E+00
- 0. OOE+00
- 0. OOE+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. 00E+00 0.00E+00 o.00E+00
- 0. OOE+00 0.00E+00
- 0. OOE+00
- 0. OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.00E+00
- 0. 00E+00 0.OOE+O0 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 40
r r
f.
r r
r r
I r -,
r
[
r r
TABLE 2-14
- 1 QUARTER 2004 BATCH RELEASES TEEN DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM).
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION TOTAL
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00 o. OOE.00
- 0. OOE+00 o
- OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.00E+00 0.OOB+00
- 0. OOE+00
- 0. ooe+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION TOTAL 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
)
0.OOE+00 0.00E+00
- 0. 00E+00
- 0. 008+00 0.00E+00 0.OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00.E+00
- 0. OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION TOTAL MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION 0.00E+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. OOE+00
- 0. o0E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+O0 0..00000
- 0. 00E+00 0.005+00 0.0 0E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. 005+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00
- 0. OOZ+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.OOE+00 0.00E+00
- 0. 00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 41
(
r r
r r
r r r
r r
r r
r
(
r r
r TABLE 2-15
- 1 QUARTER 2004 CONTINUOUS RELEASES TEEN DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00+E00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00+E00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00B+00 0.003+00 0.00E+00 0.00B+00 0.003+00 0.00B+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.ooe+00 o.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.003+00 0.003+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 0.003+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 42
I r
r r
f r
r r
r f
I r,
r f
TABLE 2-16
- 1 QUARTER 2004 BATCH + CONTINUOUS RELEASES TEEN DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION TOTAL MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION TOTAL
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00 o.OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. 00E+00 0.OOE+00 0.OOE+00 0.OOE+00
- 0. 00R+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. 00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 o. OOE.00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00 0.OOE+00 0.OOE+00
- 0. 00E+00
- 0. OOE+OO o. OOEt00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+O0 0.OOE+O0 0.00E+00 0.00E+00
- 0. OOE+00 O. OOE+00
- 0. OOE+OO
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 O.OOE+00 O. OOE+0O
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+OO 0.OOE+00 0.OOE+00 0.OOE+00 0.00g+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 MILK COW MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION TOTAL MILK GOAT MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION
- 0. OOE+00 0.00E+00 0.OOE+00 0.OOE+00 O. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- o. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.00E+00
- 0. OOE+00 0.00E+00 0.OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 O.OOE+00 0.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+0O
- 0. OOE+00 0.OOE+00 o. ooe+00
- 0. OOE+00 o.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 o.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.O0E+00
- o. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.00E+00 0.OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00
- 0. 00E+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.00E+00 TOTAL 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOEi-00 43
r r
r r -
r I
r r
r r
r r
r r
TABLE 2-17
- 1 QUARTER 2004 BATCH RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00+00 0.00+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.003+00 O.OOE+00 O.OOE+00 O.OOE+00 TOTAL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 0.00+00 O.OOE+300 0.00+00 0.003+00 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 O.OOE+00 0.003+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00+00 MEAT CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 TOTAL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.003+OO O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 0.003+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 0.0O0+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00+00 O.OOE+00 O.OOE+00 MEAT CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 0.00E+00 COW MILK CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OO+00 O.OOE+00 0.003+00 TOTAL O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MEAT CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.ooe+00 o.OOE+00 O.OOE+00 O.OOE+00 GOAT MILK CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 TOTAL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 44
r I
I
[
r r
r r
r r
r
[
r r
r TABLE 2-18
- 1 QUARTER 2004 CONTINUOUS RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OPFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 O.OOE+00 0.OOE+00 0.OOE+00 EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 TOTAL 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE;00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 O.OOE+00 EXPOSURE TO SOIL 0.00E400 0.OOE+00 0.OOE+00 0.O+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.003+00 0.00B+00 0.00E+00 0.00E+00 0.00E+00 O.OOE+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 TOTAL 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.OOE+00 0.00E+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 O.00E+00 0.00E+00 TOTAL O.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 45
r I
r f
r r
I I
f
[
r
(
r I
r TABLE 2-19
- 1 QUARTER 2004 BATCH + CONTINUOUS RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES)
AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION 0.00E+00 0.00E+00 0.00Z+00 0.0000 0.OOE+00 0.OOE+00 0.000+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 O.OOE+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0,00.E+00 PRODUCE CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.oE+o00
- o. 00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 MILK COW MAXIMUM LOCATION AIR INHALATION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 COW MILK CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 MILK GOAT MAXIMUM LOCATION AIR INHALATION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 O.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 46
r r
I r I I
I I
I I
I I
[ I r
TABLE 2-20
- 1 QUARTER 2004 BATCH RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES)
AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0 OOE+00 0 00B+00 0 OOE+00
- 0. 00E+00 0 OOE+00 0.00E+00
- 0. OOE+00
- 0. OOE+00 TOTAL MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOB+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 O. OOE+00
- 0. O0E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0 OOE+00 0 OOE+00 0 OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0 OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0 OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0 OOE+00 0 OOE+00
- 0. OOE+00 TOTAL 0.OOE+00 0.00E+00 0.00E+00 0.00S+00 0.00E+00 0.OOE+00 0.OOEi00 0.OOE+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00 0.00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00 0.OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. 00E00
- 0. OOE+00
- 0. OOE+00 0 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00 TOTAL 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION
- 0. 00E+00
- 0. 003+00
- 0. 00E+00
- 0. 00E+00
- o. 00+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00 0 OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 003+00
- 0. 00E+00
- 0. OOE+00
- 0. 003.00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00 0 OOE+00
- 0. 00E+00
- 0. 003+00
- 0. 00E+00 TOTAL 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 47
r r
r
(
t(
r r
r r
(
f r
t TABLE 2-21 1 QUARTER 2004 CONTINUOUS RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.001+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.001+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.001+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.001+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.001+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.001+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.ooe+00 o.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.001+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 48
r I
r f
I I
I I
I r
TABLE 2-22
- 1 QUARTER 2004 BATCH + CONTINUOUS RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 TOTAL 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.008+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 TOTAL 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MILK COW MAXIMUM LOCATION AIR INHALATION 0.00E+00 0.00E+00, 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 0.003+00 0.00E+00 O.OOE+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MILK GOAT MAXIMUM LOCATION AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 49
r r
f rr r
r r
r r
(
r r
r r
r TABLE 2-23
- 2 QUARTER 2004 BATCH RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
__--------------------------__---------------__----_---_,_--------------------__--____-_s TOTAL 9:-::Po.SURE..OCATION AND PATHWAY DONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 0.00+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL O.OOE+00 0.00o+00 0.00+00 O.OOE+00 0.00+00 O.O+00 O.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+O0 0.00+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 0.00+00 0.003+00 0.00+00 0.00E+00 0.00+00 O.OOE+00 o.oOE+00 TOTAL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 0.00+00 O.OO+00 0.00E+00 0.00o+00 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.003+00 O.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION 0.00E+00 O.OOE+00 0.003+OO O.OOE+00 O.OOE+00 0.003+00 O.OOE+00 O.OOE+00 MEAT CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 0.00+00 O.OOE+00 0.ooe+00 o.OOE+00 O.OOE+00 TOTAL O.OOE+00 O.OOE+00 0.OOE+00 0.00+00 0.00+00 O.OOE+00 O.OOE+00 O.OOE+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O EXPOSURE TO SOIL O.OOE+00 0.00+00 O.OOE+00 0.00+00 O.OOE+00 O.OOE+00 0.003+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 0.003+00 O.OOE+00 O.OOE+00 O.OO+00 O.OOE+00 O.OOE+00 O.OOE+00 MEAT CONSUMPTION O.OOE+00 0.003+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 COW MILK CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 TOTAL O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 0.00+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.003+00 O.OOE+00 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 0.00+00 0.003+00 0.003+00 O.OOE+00 O.ooE+00 0.003+00 O.OOE+00 MEAT CONSUMPTION O.OOE+00 O.OOE+00 0.0O3+00 O.OOE+00 O.OOE+00 0.00E+OO 0.003+00 O.OOE+00 GOAT MILK CONSUMPTION O.OOE+00 O.OOE+00 0.00+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 TOTAL 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 50
r r
r r
r r
r I
f r
I I
I r
I TABLE 2-24
- 2 QUARTER 2004 CONTINUOUS RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION
- 0. OOE+00
- 0. OOEO00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. O0E+00
- 0. 00E+00
- 0. OOE+00 0.00B+00 O. OOE+00 0.OOE+00 0.00E+00 0.00E+00
- 0. 00s+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. OO.B+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00B+00 O.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00B+00 0.00E+00 O.OOE+00 TOTAL MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00
- 0. 00E+00 0.00E+00
- 0. OOE+00 0.00E+00 o.OOE+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.OOE+00 0.OOE+00
- 0. 00E+00
- 0. OOE+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. 00E+00 0.OOE+00 O.
00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00 0.OOE+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION TOTAL MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION
- 0. OOE+OO 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.00E+00 o.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00OE+00 0.00E+00 o.00E+00 O.OOE+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O. OOE+00 0.00E+00
- 0. OOE+00 0.005E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00B+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 O.00E+00
- 0. OOE+00 0.00E+00 0.00E+00 0.00E+00 O.00E+00 O.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O.OOE+00 0.00E+00
- 0. 005+00
- 0. 00E+00
- 0. OOE+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00 0.OOE+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 O.OOE+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 51
I r f r
IrI r I r
I TABLE 2-25
- 2 QUARTER 2004 BATCH + CONTINUOUS RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OPFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN OARDEN MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION TOTAL MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION TOTAL 0.OOE+00 0.OOE+00 0.OOE+00 0;00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE4.00 0.OOE+00 0.00E4.00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE.00 0.OGE.00 0.00E+00 0.00E+00 0.005+00 0.00s+00 0.005+00 0.0oOE00 O.O00E00 0.00E+00
- 0. 00R+00
- 0. OOE+00 0.OOE+00
- 0. ooe+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.OOE+00 O.00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.OOE+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 O.00E+00
- 0. 00E+00
- 0. 00E+00 O. 005+00 0,00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+O0 0.00E+00 0.00E+00 0.00E+00 MILK COW MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION TOTAL MILK GOAT MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION
- 0. OOE+00 0.00E+00
- 0. 00E+00 0.OOE+00 0.OOEi00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 o.OOE+00
- 0. OOE+00 0.00E+00
- 0. OOE+00 0.00E+00 0.00E+00
- 0. ooE+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.00E+00 0.00E+00 0.OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00 0.00E+00
- 0. 00E+00
- 0. OOE+00 0.OOE+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00 0.00E+00
- 0. OOE+00 0.00E+00 0.OOE+00
- 0. OOE+00 0.00E+00 0.OOE+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00 O.00E+00 0.00E+00 0.00Ef00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 O.OOE+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. 005.00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00 O. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.OOE+00 0.00E+00 0.O0E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 TOTAL 0.OOE+00 0.005+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 O.OOE+00 0.ooe+00 52
f C
I I
I r
I r
I II[
I I
f I'
f TABLE 2-26
- 2 QUARTER 2004 BATCH RELEASES TEEN DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERSI AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION TOTAL MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION TOTAL MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION TOTAL MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION TOTAL 0.00.E00 0.00E+00 0.00E+00
- 0. 003+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00 0.0OE+00 0.00E+00
- 0. 00E00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00B+00 0.00E+00 0.00E+OO
- 0. OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003E00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00B+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 003+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 o.ooe+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 O.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O.OOE+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 O.OO+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 O.OOE+00 0.00E+00 O.OOE+00 0.00o+00
- o. 00E00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00B+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O.OOE+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 53
r r
r r
r r
r r I I
r r
r I
TABLE 2-27
- 2 QUARTER 2004 CONTINUOUS RELEASES TEEN DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 0.OOE+00 0.OOE+00 o.ooz+oo O.OOE+00 0.00E+OO O.00E+OO OOE+00 EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.O0E+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 o.OOE+00 0.OOE+00 0.00E+00 O.00E+O0 0.00E+00 0.OOE+00 TOTAL O.O0E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.008+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OO0E+00 0.00Z+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00R+00 0.OOE+00 0.00E+00 0.00E+00 TOTAL 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0..0E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00B+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.0OE+00 0.00Z+00 0.OOE+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00R+00
.OOE000
.OOE+00 0.003+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.003+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.00E+00 0.003+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.003+00 O.O0E+00 O.00E+00 O.00E+00 0.003+00 0.0oz+00 0.000+00 0.OOE+00 GOAT MILK CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 TOTAL 0.OOE+00 0.00E+00 0.003+00 0.00E+00 0.003+00 0.003+00 0.00E+00 0.00o+00 54
r r
r r
r r
[
r r
r r
TABLE 2-28
- 2 QUARTER 2004 BATCH + CONTINUOUS RELEASES TEEN DOSES PROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFPSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION 0.009+00 0.00+E00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.009+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.009+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.009+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.OOE+00 0.00E+00 0.009+00 0.00E+00 O.00E+00 O.OOE+00 0.OOE+00 MILK COW MAXIMUM LOCATION AIR INHALATION 0.00E+00 0.009+00 0.009+00 0.000+00 0.00E+00 0.00E+00 0.00E+00 0.009+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00Z+00 0.00E+00 O.OOE+00 O.00g+00 0.009+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 0.009+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.009+00 0.00E+00 0.00E+00 TOTAL 0.00Z+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 MILK GOAT MAXIMUM LOCATION AIR INHALATION 0.009+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.009+00 0.009+00 0.00E+00 0.00E+00 O.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.009+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00S+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 55
r r
rr r
IrIr
[
F
[
I r
r r
I r TABLE 2-29
- 2 QUARTER 2004 BATCH RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.008+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 0.ooe+00 o.00E+00 0.00E+00 0.00+E00 0.008+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.008+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00+E00 0.00E+00 0.00E+00 0.ooe+00 o.OOE+00 EXPOSURE TO SOIL 0.00+E00 0.00E+00 0.00E+00 0.00+E00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.008+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 TOTAL 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.008+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.OOE+00 0.008+00 0.00E+00 0.00+E00 0.00E+00 0.00E+00 0.008+00 PRODUCE CONSUMPTION 0.008+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.008+00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00+E00 0.00E+00 0.00E+00 0.00E+00 0.00+E00 0.008+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.008+00 0.008+00 0.008+00 0.00E+00 GOAT MILK CONSUMPTION 0.008E00 0.00E+00 0.008+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 56
,r r
r r
r r
r r
r r
r TABLE 2-30
- 2 QUARTER 2004 CONTINUOUS RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 O.OOE+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.009+00 0.00E+00 0.OOE+00 0.008+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.009+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.009+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.009+00 0.00E+00 0.009+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00B+00 0.00E+00 0.009+00 0.00B+00 b.00E+00 0.009+00 0.009+00 EXPOSURE TO SOIL 0.009+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.009+00 0.009+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.ooe+00 o.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O.OOE+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.009+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.009+00 0.009+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.009+00 0.009+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.009+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.009+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.009+00 0.00E+00 0.009+00 0.009+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 57
r r r I
I r
I r
I f I r
I r
I r
TABLE 2-31
- 2 QUARTER 2004 BATCH t CONTINUOUS RELEASES CHILD DOSES PROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY GARDEN MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION TOTAL MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION TOTAL MILK COW MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION TOTAL MILK GOAT MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION TOTAL TOTAL BODY THYROID KIDNEY DONE LIVER LUNG GI-LLI SKIN
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00 0.00E+00
- 0. OOe+o0 o.OOE+00
- 0. 00E+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. 00o+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. 00R+00 0.OOE+00
- 0. 00B+00 0.OOE+00 0.00E+00 0.00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.00E+00 0.00E+00
- 0. 00E+00 0.0oE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. 00E+00 0.OOE+00 0.00+E00
- 0. 00E+00
- 0. OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00 0.00E500
- 0. 00E+00 0.00E+00 0.00E+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.00E+00
- 0. OOE+00 0.00B+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.0OE+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00 0.OOE+00 0.00E+00
- 0. 005+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. OOE+00
- 0. 00B+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. 00E+00 0.00E+00 0.OOE+00 0.00E+00
- 0. OOE+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00B+00 0.00E+00 0.00E+00
- 0. OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.005+00 0.00E+00 0.005+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.005+00 0.00E+00 0.00++00 0.000+00 0.005+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 58
[
r r
[
r
(
[
r r
r
(
I I
r TABLE 2-32
- 2 QUARTER 2004 BATCH RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS CMREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 EXPOSURE TO SOIL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 O.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00B+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00B+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 O.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL O.00E+00 0.00E+00 O.00E+00 0.00E+00 0.003+00 0.OOE+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.003+00 0.OOE+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.001+00 0.001+00 0.00E+00 EXPOSURE TO SOIL 0.001+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.001+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.001+00 0.00E+00 0.00E+00 0.001+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.001+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 59
r r
r r
r r
r r r
r r
r r
r r
TABLE 2-33
- 2 QUARTER 2004 CONTINUOUS RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+0O 0.00E+00 0.OOE+00 EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 TOTAL 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.OOE+00 0.OOE+00 0.OOE+00 0.00B+00 0.00E+00 0.00E+OO 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 O.00E+00 O.OOE+00 0.00E+00 0.00E+00 0.00+00 TOTAL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.OOE+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION O.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00Z+00 0.OOE+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00B+00 0.00E+00 TOTAL 0.OOE+00 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 O.003+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 0.00B+00 0.OOE+00 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.OOE+00 0.003+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 60
r r
r r
r r
r r
r r
r r
r r
r TABLE 2-34 i 2 QUARTER 2004 BATCH + CONTINUOUS RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION 0.OOE+00 O.00E+0O O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 PRODUCE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+0O 0.OOE+O0 O.OOE+00 0.OOE+00 0.OOE+00 TOTAL O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 PRODUCE CONSUMPTION O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MEAT CONSUMPTION O.OOE+O0 0.OOE+OO 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 TOTAL 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MILK COW MAXIMUM LOCATION AIR INHALATION 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+0OO LEAFY VEGETABLE CONSUMPTION 0.OOE+O0 O.OOE+00 0.OOE+OO O.OOE+00 O.0OOE+00 O.OOE+OO O.OOE+00 O.OOE+OO PRODUCE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+00 MEAT CONSUMPTION O.OOE+OO O.OOE+00 0.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 COW MILK CONSUMPTION O.OOE+O0 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 TOTAL O.OOE+OO O.OOE+00 O.OO+0OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MILK GOAT MAXIMUM LOCATION AIR INHALATION O.OOE+00 O.OOE+OO O.OOE+000 0.00+00 0.001+00 0.OOE+00 O.OOE+0OO 0.OOE00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+0OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+0OO O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+
- 0.
+00 O.OO+0 O.E+OO00 O.OOE+
O.OOE+00 0.001+00 O.OOE+00 MEAT CONSUMPTION O.OOE+OO O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 GOAT MILK CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+O0 TOTAL O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 61
r t
r r
r r
r r
r r
f r
r TABLE 2-35
- 3 QUARTER 2004 BATCH RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL E::,-3UPE t.0CATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663.
METERS)
AIR INHALATION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 TOTAL O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+O0 O.OOE+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 MEAT CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 TOTAL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MiLk.
%.;v (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+O0 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 MEAT CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 COW MILK CONSUMPTION O.OOE+00 0.0OE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 TOTAL O.OOE+00 O.OOE+
O.OOE+
O O.OOE0 0.00E+00 0.OE+O0 0.E+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.OOE+00 o.00E+00 0.00E+00 0.OOE+00 O.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 O.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 62
r r
(
t r
r
(
I r
r r
TABLE 2-36
- 3 QUARTER 2004 CONTINUOUS RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.12E-10 1.23E-12 3.23E-11 0.00E+00 4.40E-13 4.97E-11 3.74E-12 3.23E-1l EXPOSURE TO SOIL 1.16B-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.71E-09 1.40E-11 6.72E-10 0.00E+00 4.76E-12 1.58E-12 7.83E-11 6.72E-10 PRODUCE CONSUMPTION 1.46E-08 7.57E-11 3.63E-09 0.00E+00 2.57E-11 8.54E-12 4.23E-10 3.63E-09 TOTAL 1.80E-08 2.06E-10 4.45E-09 1.16E-10 1.46E-10 1.75E-10 6.20E-10 4.47E-09 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.12E-10 1.23E-12 3.23E-11 0.00E+00 4.40E-13 4.97E-11 3.74E-12 3.23E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.71E-09 1.40E-11 6.72E-10 0.OOE+00 4.76E-12 1.58E-12 7.83E-11 6.72E-10 PRODUCE CONSUMPTION 1.46E-08 7.57E-11 3.63E-09 0.00E+00 2.57E-11 8.54E-12 4.23E-10 3.63E-09 MEAT CONSUMPTION 3.04E-10 1.06E-11 7.97E-11 0.00E+00 3.60E-12 1.20E-12 8.77E-12 7.97E-11 TOTAL 1.83E-08 2.17E-10 4.53E-09 1.16E-10 1.50E-10 1.76E-10 6.29E-10 4.55E-09 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.12E-10 1.23E-12 3.23E-11 0.00E+00 4.40E-13 4.97E-11 3.74E-12 3.23E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 r.:;E AbI.E $.2!.1'!Mvr;.:N 2'-;E 09 1.40E 11 6.72E-10 0.OOE.00 4.76E-12 1.58E-12 7.83E-11 6.72E-10 PRODUCE CONSUMPTION 1.46E-08 7.57E-11 3.63E-09 0.00E+00 2.57E-11 8.54E-12 4.23E-10 3.63E-09 MEAT CONSUMPTION 3.04E-10 1.06E-11 7.97E-11 0.00E+00 3.60E-12 1.20E-12 8.77E-12 7.97E-11 COW MILK CONSUMPTION 1.18E-09 8.98E-11 3.33E-10 0.00E+00 3.05E-11 1.01E-11 3.40E-11 3.33E-10 TOTAL 1.95E-08 3.07E-10 4.863-09 1.16E-10 1.81E-10 1.87E-10 6.63E-10 4.88E-09 MILK GOAT (NORTH SECTOR AT 663.
METERS)
AIR INHALATION 5.12E-10 1.23E-12 3.23E-11 0.00E+00 4.40E-13 4.97E-11 3.74E-12 3.23E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.71E-09 1.403-11 6.72E-10 0.00E+00 4.76E-12 1.58E-12 7.83E-11 6.72E-10 PRODUCE CONSUMPTION 1.46E-08 7.57E-11 3.63E-09 0.00E+00 2.57E-11 8.54E-12 4.23E-10 3.63E-09 MEAT CONSUMPTION 3.04E-10 1.06E-11 7.97E-11 0.00E+00 3.60E-12 1.20E-12 8.77E-12 7.97E-11 GOAT MILK CONSUMPTION 2.54E-09 2.69E-10 7.51E-10 0.00E+00 9.15E-11 3.04E-11 7.29E-11 7.51E-10 TOTAL 2.08E-08 4.87E-10 5.28E-09 1.16E-10 2.41E-10 2.07E-10 7.02E-10 5.303-09 63
{
r r ~ r -
( -
r C
(
I, r r
(
r r
TABLE 2-37
- 3 QUARTER 2004 BATCH + CONTINUOUS RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE CASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREMI
-TOTAL--
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION 5.12E-10 1.23E-12 3.23E-11 0.00E+00 4.40E-13 4.97E-11 3.74E-12 3.23E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.71E-09 1.40E-11 6.72E-10 0.00E+00 4.76E-12 1.58E-12 7.83E-11 6.72E-10 PRODUCE CONSUMPTION 1.46E-08 7.57E-11 3.63E-09 0.00E+00 2.57E-11 8.54E-12 4.23E-10 3.63E-09 TOTAL 1.80E-08 2.06E-10 4.45E-09 1.16E-10 1.46E-10 1.75E-10 6.20E-10 4.47E-09 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION 5.12E-10 1.232-12 3.23E-11 O.00E+00 4.40E-13 4.972-11 3.74E-12 3.232-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.71E-09 1.40E-11 6.72E-10 0.00E+00 4.76E-12 1.58E-12 7.83E-11 6.72E-10 PRODUCE CONSUMPTION 1.46E-0 7.57E-11 3.63E-09 0.00E+00 2.57E-11 8.54E-12 4.23E-10 3.63E-09 MEAT CONSUMPTION 3.04E-10 1.06E-11 7.97E-11 0.00E+00 3.60E-12 1.20E-12 8.77E-12 7.97E-11 TOTAL 1.83E-08 2.17E-10 4.53E-09 1.16E-10 1.50E-10 1.76E-10 6.29E-10 4.55E-09 MILK COW MAXIMUM LOCATION AIR INHALATION 5.12E-10 1.23E-12 3.23E-11 0.00E+00 4.40E-13 4.97E-11 3.74E-12 3.23E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.71E-09 1.40E-11 6.72E-10 0.00+E00 4.76E-12 1.58E-12 7.83E-11 6.72E-10 PRODUCE CONSUMPTION 1.46E-08 7.57E-11 3.63E-09 0.00E+00 2.57E-11 8.54E-12 4.23E-10 3.63E-09 MEAT CONSUMPTION 3.04E-10 1.06E-11 7.97E-11 0.00E+00 3.60E-12 1.20E-12 8.77E-12 7.97E-11 COW MILK CONSUMPTION 1.18E-09 8.98E-11 3.33E-10 0.00E+00 3.05E-11 1.01E-11 3.40E-11 3.33E-10 TOTAL 1.95E-08 3.07E-10 4.86E-09 1.16E-10 1.81E-10 1.87E-10 6.63E-10 4.88E-09 MILK GOAT MAXIMUM LOCATION AIR INHALATION 5.12E-10 1.23E-12 3.23E-11 0.00E+00 4.40E-13 4.97E-11 3.74E-12 3.23E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-20 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.71E-09 1.40E-11 6.72E-10 0.00E+00 4.76E-12 1.58E-12 7.83E-11 6.72E-10 PRODUCE CONSUMPTION 1.46E-08 7.57E-11 3.63E-09 0.00E+00 2.57E-11 8.54E-12 4.23E-10 3.63E-09 MEAT CONSUMPTION 3.04E-10 1.06E-11 7.97E-11 0.00E+00 3.60E-12 1.20E-12 8.77E-12 7.97E-11 GOAT MILK CONSUMPTION 2.54E-09 2.69E-10 7.51E-10 0.00E+00 9.15E-11 3.04E-11 7.29E-11 7.51E-10 TOTAL 2.08E-08 4.87E-10 5.28E-09 1.16E-10 2.41E-10 2.07E-10 7.02E-10 5.30E-09 64
Ir f
I IIr I
[
F F
F U,
V I
TABLE 2-38
- 3 QUARTER 2004 BATCH RELEASES TEEN DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OPFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 PRODUCE CONSUMPTION o.ooZ+00 O.OOE+OO 0.00E+00 O.OOE+OO O.OOE+00 O.OOE+oo o.OOE*+OO O.OOE+OO TOTAL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+O0 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+O0 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 PRODUCE CONSUMPTION O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MEAT CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 TOTAL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 0.OOE+00 0.00+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.OOE+00 O.OOE+OO O.OE+O00 0.005+00 O
.OOE +00 0.00E+0O LEAFY VEGETABLE CONSUMPTION O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MEAT CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00O O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+O0 COW MILK CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 TOTAL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION O.OOE+00 O.00E+00 0.OOE+00
.OOE+00
.OOE+00 O.OOE+00
.OOE+00 O.OOE+00 PRODUCE CONSUMPTION O.OOE+00 0.ooe+00 o.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MEAT CONSUMPTION O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 GOAT MILK CONSUMPTION O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 TOTAL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 65
I r
r r
r r
rr r
r r
I r
r I r TABLE 2-39
- 3 QUARTER 2004 CONTINUOUS RELEASES TEEN DOSES FROM.GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.58E-10 1.68E-12 3.51E-11 0.OOE+00 6.02E-13 8.52E-11 3.96E-12 3.51E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-1O 1.16E-10 1.16E-1O 1.16E-10 1.16E-10 1.16E-1O 1.35E-10 LEAFY VEGETABLE CONSUMPTION 1.95E-09 1.26E-11 4.84E-10 0.00E+00 4.28E-12 1.66E-12 5.47E-11 4.84E-10 PRODUCE CONSUMPTION 2.07E-08 1.33E-10 5.13E-09 0.OOE+00 4.54E-11 1.76E-11 5.80E-10 5.13E-09 TOTAL 2.33E-08 2.63E-10 5.76E-09 1.16E-10 1.66E-10 2.20E-10 7.54E-10 5.78E-09 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.58E-10 1.68E-12 3.S1E-11 0.OOE+00 6.02E-13 8.52E-11 3.96E-12 3.51E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 1.95E-09 1.26E-11 4.84E-10 0.OOE+00 4.28E-12 1.66E-12 5.47E-11 4.84E-10 PRODUCE CONSUMPTION 2.07E-08 1.33E-10 5.13E-09 0.00E+OO 4.54E-11 1.76E-11 S.80E-10 5.13E-09 MEAT CONSUMPTION 1.98E-10 8.57E-12 5.04E-11 0.OOE+00 2.92E-12 1.13E-12 5.51E-12 5.04E-11 TOTAL 2.35E-08 2.72E-10 5.81E-09 1.16E-10 1.69E-10 2.21E-10 7.59E-10 5.83E-09 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.58E-10 1.68E-12 3.51E-11 O.OOE+00 6.02E-13 8.52E-11 3.96E-12 3.51E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 1.95E-09 1.26E-11 4.84E-1O O.O0E+00 4.28E-12 1.66E-12 5.47E-11 4.84E-10 PRODUCE CONSUMPTION 2.07E-08 1.33E-10 5.13E-09 0.OOE+00 4.54E-11 1.76E-11 5.SOE-10 5.13E-09 MEAT CONSUMPTION 1.98E-10 8.57E-12 5.04E-11 0.OOE+00 2.92E-12 1.13E-12 5.51E-12 5.04E-11 COW MILK CONSUMPTION 1.69E-09 1.58E-10 4.44E-10 0.00E+00 5.39E-11 2.09E-11 4.65E-11 4.44E-10 TOTAL 2.52E-08 4.30E-10 6.26E-09 1.16E-10 2.23E-10 2.42E-10 8.06E-10 6.28E-09 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.58E-10 1.68E-12 3.51E-11 0.00,E00 6.02E-13 8.52E-11 3.96E-12 3,51E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 1.95E-09 1.26E-11 4.84E-10 0.00E+00 4.28E-12 1.66E-12 5.47E-11 4.84E-10 PRODUCE CONSUMPTION 2.07E-08 1.33E-10 5.13E-09 0.00E+00 4.54E-11 1.76E-11 5.80E-10 5.13E-09 MEAT CONSUMPTION 1.98E-10 8.57E-12 5.04E-11 0.00E+00 2.92E-12 1.13E-12 5.51E-12 5.04E-11 GOAT MILK CONSUMPTION 3.67E-09 4.758-10 9.83E-10 0.00E+00 1.62E-10 6.28E-11 9.97E-11 9.83E-10 TOTAL 2.72E-08 7.47E-10 6.80E-09 1.16E-10 3.30E-10 2.84E-10 8.59E-10 6.82E-09 66
r r
r r
r r
I r
r r
TABLE 240
- 3 QUARTER 2004 BATCH + CONTINUOUS RELEASES TEEN DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION 5.58E-10 1.68E-12 3.51E-11 O.OOE+00 6.02E-13 8.52E-11 3.96E-12 3.51E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-1O 1.35E-10 LEAFY VEGETABLE CONSUMPTION 1.95E-09 1.26E-11 4.84E-10 0.00E+00 4.28E-12 1.66E-12 5.47E-11 4.84E-10 PRODUCE CONSUMPTION 2.07E-08 1.33E-10 5.13E-09 O.OOE+00 4.54E-11 1.76E-11 5.80E-1O 5.13E-09 TOTAL 2.33E-08 2.63E-10 5.76E-09 1.16E-10 1.66E-10 2.20E-10 7.54E-10 5.78E-09 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION 5.58E-10 1.68E-12 3.51E-11 0.OOE+00 6.02E-13 8.52E-11 3.96E-12 3.51E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 1.95E-09 1.26E-11 4.84E-10 O.OOE+00 4.28E-12 1.66E-12 5.47E-11 4.84E-10 PRODUCE CONSUMPTION 2.07E-08 1.33E-10 5.13E-09 O.OOE+00 4.54E-11 1.76E-11 5.80E-1 5.13E-09 MEAT CONSUMPTION 1.98E-l 8.57E-12 5.04E-11 O.OOE+00 2.92E-12 1.13E-12 5.51E-12 5.04E-li TOTAL 2.35E-08 2.72E-10 5.81E-09 1.16E-10 1.69E-10 2.21E-10 7.59E-10 5.83E-09 MILK COW MAXIMUM LOCATION AIR INHALATION 5.58E-10 1.68E-12 3.51E-11 0.OOE+00 6.02E-13 8.52E-11 3.96E-12 3.51K-ll EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-1 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 1.95E-09 1.26E-11 4.84E-10 0.OOE+00 4.28E-12 1.66E-12 5.47E-11 4.84E-10 PRODUCE CONSUMPTION 2.07E-08 1.33E-10 5.13E-09 0.00E+00 4.54E-11 1.76E-11 5.80E-10 5.13E-09 MEAT CONSUMPTION 1.98E-10 8.57E-12 5.04E-11 O.O0E+00 2.92E-12 1.13E-12 5.51E-12 5.04E-11 COW MILK CONSUMPTION 1.69E-09 1.58E-10 4.44E-10 0.00+00 3.39E-11 2.09E-11 4.65E-11 4.44E-10 TOTAL 2.52E-08 4.30E-10 6.26E-09 1.16E-10 2.23E-10 2.42E-10 8.06E-10 6.28E-09 MILK GOAT MAXIMUM LOCATION AIR INHALATION 5.58E-10 1.68E-12 3.51K-11 O.0OE+00 6.02E-13 8.52E-11 3.96E-12 3.51K-li EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35K-10 LEAFY VEGETABLE CONSUMPTION 1.95E-09 1.26K-11 4.84E-10 0.00E+00 4.28E-12 1.66E-12 5.47E-11 4.84E-10 PRODUCE CONSUMPTION 2.07E-08 1.33E-10 5.13E-09 0.OOE+00 4.54E-11 1.76E-11 5.80E-10 5.13E-09 MEAT CONSUMPTION 1.98E-10 8.57E-12 5.04E-11 0.OOE+00 2.92E-12 1.13E-12 5.51E-12 5.04K-11 GOAT MILK CONSUMPTION 3.67E-09 4.75E-10 9.83E-10 O.OOE+00 1.62E-10 6.28E-11 9.97E-11 9.83E-10 TOTAL 2.72E-08 7.47E-10 6.80E-09 1.16E-10 3.30E-10 2.84E-10 8.59K-10 6.82E-09 67
Ir r
rI r
r r
r r
I' I
r r
r f TABLE 241
- 3 QUARTER 2004 BATCH RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFPSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.00E+00 0.00B+00 O.OOE+00 0.OOE+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00B+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION O.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 TOTAL 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.0OE+00 0.OOE+00 0.00E+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 EXPOSURE TO SOIL 0.DOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 O.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 MEAT CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 O.OOE+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.O0E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00B+00 0.00E+00 0.00E+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 0.OOE+00 0.005+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 GOAT MILK CONSUMPTION 0.00E+00 0.00E+00 0.005+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 68
r r
r r
r r
r r
r r
r r
TABLE 2-42
- 3 QUARTER 2004 CONTINUOUS RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.23E-10 1.63E-12 3.3SE-11 0.OOE+00 5.59E-13 7.63E-11 1.78E-12 3.35E-11 EXPOSURE TO SOIL 1.1GE-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.48E-09 1.64E-11 6.27E-10 0.OOE+00 5.33E-12 1.92E-12 3.33E-11 6.27E-10 PRODUCE CONSUMPTION 3.57E-08 2.35E-10 9.01E-09 0.OOE+00 7.67E-11 2.76E-11 4.79E-10 9.01E-09 TOTAL 3.88E-08 3.69E-10 9.79E-09 1.16E-10 1.98E-10 2.21E-10 6.29E-10 9.81E-09 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.23E-10 1.63E-12 3.35E-11 0.00E+00 5.59E-13 7.63E-11 1.78E-12 3.35E-ll EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.48E-09 1.64E-11 6.27E-10 0.OOE+00 5.33E-12 1.92E-12 3.33E-11 6.27E-10 PRODUCE CONSUMPTION 3.57E-08 2.35E-10 9.01E-09 0.00E+00 7.67E-11 2.76E-11 4.79E-10 9.01E-09 MEAT CONSUMPTION 2.60E-10 1.14E-11 6.45E-11 0.00E+00 3.70E-12 1.33E-12 3.41E-12 6.45E-l1 TOTAL 3.90E-08 3.80E-10 9.85E-09 1.16E-10 2.02E-10 2.23E-10 6.32E-10 9.87E-09 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.23E-10 1.63E-12 3.35E-11 0.00E+00 5.59E-13 7.63E-11 1.78E-12 3.35E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.48E-09 1.64E-11 6.27E-10 0.00E+00 5.33E-12 1.92E-12 3.33E-11 6.27E-10 PRODUCE CONSUMPTION 3.57E-08 2.35E-10 9.01E-09 0.00E+00 7.67E-11 2.76E-11 4.79E-10 9.01E-09 MEAT CONSUMPTION 2.60E-10 1.14E-11 6.45E-11 0.00E+00 3.70E-12 1.33E-12 3.41E-12 6.45E-11 COW MILK CONSUMPTION 2.95E-09 2.75E-10 7.16E-10 0.OOE+00 8.95E-11 3.22E-11 3.76E-11 7.16E-10 TOTAL 4.20E-08 6.55E-10 1.06E-08 1.16E-10 2.91E-10 2.55E-10 6.70E-10 1.06E-08 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.23E-10 1.63E-12 3.35E-11 0.00E+00 5.59E-13 7.63E-11 1.78E-12 3.35E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.48E-09 1.645-11 6.27E-10 0.00E+00 5.33E-12 1.92E-12 3.33E-11 6.27E-10 PRODUCE CONSUMPTION 3.57E-08 2.35E-10 9.01E-09 0.00E+00 7.67E-11 2.76E-11 4.79E-10 9.01E-09 MEAT CONSUMPTION 2.60E-10 1.14E-11 6.45E-11 0.00E+00 3.70E-12 1.33E-12 3.41E-12 6.45E-ll GOAT MILK CONSUMPTION 6.45E-09 8.24E-10 1.54E-09 0.00E+00 2.68E-10 9.66E-11 8.05E-11 1.54E-09 TOTAL 4.55E-08 1.20E-09 1.14E-08 1.16E-10 4.70E-10 3.19E-10 7.13E-10 1.14E-08 69
r r
r r
r r
[
t-(
(
V -f TABLE 243
- 3 QUARTER 2004 BATCH + CONTINUOUS RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION 5.23E-10 1.63E-12 3.35E-11 0.00E+00 5.59E-13 7.63E-11 1.78E-12 3.35E-11 EXPOSURE TO SOIL 1.163-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.48E-09 1.64E-11 6.27E-10 0.OOE+00 5.33E-12 1.92E-12 3.33E-11 6.27E-10 PRODUCE CONSUMPTION 3.57E-08 2.35E-10 9.01E-09 0.00E+00 7.67E-11 2.76E-11 4.79E-10 9.01E-09 TOTAL 3.88E-08 3.69E-10 9.79E-09 1.16E-10 1.98E-10 2.21E-10 6.29E-10 9.81E-09 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION 5.23E-10 1.63E-12 3.35E-11 0.OOE+00 5.59E-13 7.63E-11 1.78E-12 3.35E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.48E-09 1.64E-11 6.27E-10 O.00E+O0 5.33E-12 1.92E-12 3.333-11 6.27E-10 PRODUCE CONSUMPTION 3.57E-08 2.35E-10 9.01E-09 0.00E+00 7.67E-11 2.76E-11 4.79E-10 9.01E-09 MEAT CONSUMPTION 2.60E-10 1.14E-11 6.45E-11 0.00E+00 3.70E-12 1.33E-12 3.41E-12 6.45E-11 TOTAL 3.90E-08 3.80E-10 9.85E-09 1.16E-10 2.02E-10 2.23E-10 6.32E-10 9.87E-09 MILK COW MAXIMUM LOCATION AIR INHALATION 5.23E-10 1.63E-12 3.35E-11 0.00E+00 5.59E-13 7.63E-11 1.78E-12 3.35E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.48E-09 1.64E-11 6.27E-10 O.00E+00 5.33E-12 1.92E-12 3.33E-11 6.27E-10 PRODUCE CONSUMPTION 3.57E-08 2.35E-10 9.01E-09 0.00E+00 7.67E-11 2.76E-11 4.79E-10 9.01E-09 MEAT CONSUMPTION 2.60E-10 1.14E-11 6.45E-11 0.00E+00 3.70E-12 1.33E-12 3.41E-12 6.45E-11 COW MILK CONSUMPTION 2.95E-09 2.753-10 7.16E-10 O.00+E00 8.95E-11 3.22E-11 3.76E-11 7.16E-10 TOTAL 4.20E-08
.6.55E-10 1.06E-08 1.16E-10 2.91E-10 2.55E-10 6.70E-10 1.06E-08 MILK GOAT MAXIMUM LOCATION AIR INHALATION 5.23E-10 1.63E-12 3.35E-11 0.00E+00 5.59E-13 7.63E-11 1.78E-12 3.35E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 2.48E-09 1.64E-11 6.27E-10 0.00E+00 5.33E-12 1.92E-12 3.33E-11 6.27E-10 PRODUCE CONSUMPTION 3.57E-08 2.35E-10 9.01E-09 0.00E+00 7.67E-11 2.76E-11 4.79E-10 9.01E-09 MEAT CONSUMPTION 2.60E-10 1.14E-11 6.45E-11 0.00E+00 3.70E-12 1.33E-12 3.41E-12 6.45E-11 GOAT MILK CONSUMPTION 6.45E-09 8.24E-10 1.54E-09 0.00E+00 2.68E-10 9.66E-11 8.05E-11 1.54E-09 TOTAL 4.55E-08 1.20E-09 1.14E-08 1.16E-10 4.70E-10 3.19E-10 7.13E-10 1.14E-08 70
r r
I r
I I
r I
I I
r r
I f r TABLE 2-44
- 3 QUARTER 2004 BATCH RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION TOTAL MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE.*00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 TOTAL M.Y t ew (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION 0.OOE+00 0.OOE+00 O.OOE+00 0.0OE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 O. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 O. OOE+00 0.OOE+00 0.OOE+00 O. OOE+00
- 0. 00E+00
- 0. OOE+00 O.OOOE00 0.OOE+00 TOTAL O.OOE+00 0.00E+00 O.00E+00 O.OOE+00 O.OOE+00
- 0. 00E+00 0.OOE+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION TOTAL 0.OOE+00 0.00E+00
- 0. OOE+00 0.00E+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00 0.00E+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.0oE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00 0.OOE+00 0.00E+00 0.00B+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 71
r r
I r
r r
r r
r r
[
r TABLE 245
- 3 QUARTER 2004 CONTINUOUS RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN tNORTH SECTOR AT 663. METERS)
AIR INHALATION 2.12B-10 1.21E-12 1.34E-11 0.00E+00 3.41E-13 5.812-11 6.78E-13 1.34E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 3.27E-10 1.17E-10 1.29E-10 1.16E-10 1.16E-10 1.74E-10 1.16E-10 1.48E-10 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 2.12E-10 1.21E-12 1.34E-11 0.00E+00 3.41E-13 5.81E-11 6.78E-13 1.34E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION O.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL.
3.27E-10 1.17E-10 1.29E-10 1.16E-10 1.16E-10 1.74E-10 1.16E-10 1.48E-10 MILK COW (NORTH SECTOR AT 663. METERS)
- ir
- N)A:.A.It;
'I.E I
1 21E 12 1.34E311 0.00E+00 3.41E-13 5.81E-11 6.78E-13 1.34E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O.OOE+00 O.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 3.36E-09 5.36E-10 7.76E-10 0.00E+00 1.44E-10 5.82E-11 3.79E-11 7.76E-10 TOTAL 3.68E-09 6.53E-10 9.05E-10 1.16E-10 2.60E-10 2.32E-10 1.54E-10 9.24E-10 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 2.12E-10 1.21E-12 1.34E-11 0.00E+00 3.41E-13 5.81E-11 6.78E-13 1.34E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.003+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 7.46E-09 1.61E-09 1.66E-09 0.00E+00 4.32E-10 1.75E-10 8.10E-11 1.66E-09 TOTAL 7.79E-09 1.72E-09 1.79E-09 1.16E-10 5.47E-10 3.48E-10 1.97E-10 1.81E-09 72
r r
r r
r r
r r
r I
r I
r I
r r
r r
r TABLE 2-46
- 3 QUARTER 2004 BATCH + CONTINUOUS RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION 2.12E-10 1.21E-12 1.34E-11 0.00E+00 3.41E-13 5.81E-11 6.78E-13 1.34E-l1 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 O.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.O0E+00 0.00E+00 TOTAL 3.27E-10 1.17E-10 1.29E-10 1.16E-10 1.16E-10 1.74E-10 1.16E-10 1.48E-10 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION 2.12E-10 1.21E-12 1.34E-11 0.OOE+00 3.41E-13 5.81E-11 6.78E-13 1.34E-ll EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 MEAT CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 TOTAL 3.27E-10 1.17E-10 1.29E-10 1.16E-10 1.16E-10 1.74E-10 1.16E-10 1.48E-10 MILK COW MAXIMUM LOCATION AIR INHALATION 2.12E-10 1.21E-12 1.34E-11 0.00E+00 3.41E-13 5.81E-11 6.78E-13 1.34E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.35E-10 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O.OOE+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OO0E+00 0.00E+00 0.00E+00 0.00E+00 COW MILK CONSUMPTION 3.36E-09 5.36E-10 7.76E-10 0.OOE+00 1.44E-10 5.82E-11 3.79E-11 7.76E-10 TOTAL 3.68E-09 6.53E-10 9.05E-10 1.16E-10 2.60E-10 2.32E-10 1.54E-10 9.24E-10 MILK GOAT MAXIMUM LOCATION AIR INHALATION 2.12E-10 1.21E-12 1.34E-11 0.00E+00 3.41E-13 5.81E-11 6.78E-13 1.34E-11 EXPOSURE TO SOIL 1.16E-10 1.16E-10 1.16E-10 1.16E-10 1.165-10 1.16E-1O 1.16E-10 1.35B-10 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 O.00E+00 PRODUCE CONSUMPTION 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 7.46E-09 1.61E-09 1.66E-09 0.00E+00 4.32E-10 1.75E-10 8.10E-11 1.66E-09 TOTAL 7.79E-09 1.72E-09 1.79E-09 1.165-10 5.47E-10 3.48E-10 1.97E-10 1.81E-09 73
r I
[
r t
r r
r I
I r
r r
r r
TABLE 2-47
- 4 QUARTER 2004 BATCH RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 EXPOSURE TO SOIL 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.O0E+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 TOTAL 0.OOE+00 0.OOE+00 O.OOE+00 O.00E+O0 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+O0 MEAT CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.0oE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 TOTAL 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 O.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 MEAT CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 COW MILK CONSUMPTION 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 TOTAL 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 MEAT CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 GOAT MILK CONSUMPTION 0.0OE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 74
r F
r r
f r
r r
I I
r
(
f f
r I
r r
TABLE 2-48
- 4 QUARTER 2004 CONTINUOUS RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION 4.79E-10 0.OOE+00
- 2. 53E-09 1.37E-08 0.OOE+00 0.00E+00
- 0. OOE+00
- 0. OOE+00 2.95E-1l
- 0. 00E+00 6.21E-10 3.35E-09 0.OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 4.64E-11 0.OOE+00 0.OOE+00
- 0. OOE+00
- 3. 49E-12
- 0. OOE+00
- 7. 32E-1l
- 3. 9SE-10
- 2. 95E-11
- 0. OOE+00
- 6. 21E-10
- 3. 35E-09 TOTAL 1.67E-08 0.OOE+00 4.OOE-09 0.OOE+00 0.OOE+00 4.64E-11 4.71E-10 4.OOE-09 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PROpUCE CONSUMPTION MEAT CONSUMPTION TOTAL 4.79E-10
- 0. OOE+00 2.53E-09 1.37E-08
- 2. 78E-10
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 2. 95E-11 0.OOE+00
- 6. 21E-10
- 3. 35E-09
- 6. 82E-11
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 0. OOE.00 0.OOE+00
- 4.64E-ll
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00 3.49E-12
- 0. OOE+00 7.32E-11
- 3. 95E-10 8.03E-12
- 2. 95E-11
- 0. OOE+00 6.21E-10 3.35E-09
- 6. 82E-11 1.69E-08 0.OOE+00 4.07E-09 0.OOE.00 0.OOE.00 4.64E-1I 4.79E-10 4.07E-09 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION TOTAL
- 4. 79E-10
- 0. OOE.00
- 2. 53E-09 1.37E-08
- 2. 78E-10 1.05E-09 0.00E+00 O. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 2. 95E-11
- 0. 00E+00
- 6. 21E-10 3.35E-09
- 6. 82E-11 2.56E-10
- 0. 00E+00 0.00E+00 0.00E+00 0.00+E00 O.00E+00 0.00E+00 0.OOE+00 0.OOE+00
- 0. 00E+00 0.00E+00
- 0. OOE+00
- 0. OOE+00 4.64E-11 0.00E+00
- 0. 00E+00 0.00E+00 0.OOE+00 0.00E+00 3.49E-12
- 0. OOE+00
- 7. 32E-11 3.95E-10 8.03E-12
- 3. 02E-11
- 2. 95E-11
- 0. OOE+00 6.21E-10 3.35E-09
- 6. 82E-11
- 2. 56E-10 1.80E-08 0.00E+00 4.33E-09 0.OOE+00 0.00E+00 4.64E-11 5.09E-10 4.33E-09 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION
- 4. 79E-10
- 0. 00E+00
- 2. 53E-09 1.37E-08 2.78E-10 2.19E-09
- 0. OOE+00
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 2. 95E-11
- 0. 00E+00 6.21E-10 3.35E-09 6.82E-11 5.39E-10 0.00E+00 0.00E+00
- 0. OOE+00 0.0OE+00
- 0. OOE+00
- 0. 00E+00 0.00E+00 4.64E-11 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 3.49E-12
- 0. OOE+00
- 7. 32E-11 3.95E-10 8.03E-12
- 6. 34E-11 2.95E-11
- 0. OOE+00 6.21E-10 3.35E-09
- 6. 82E-11 5.39E-10 TOTAL 1.91E-08 0.00E+00 4.61E-09 0.00E+00 0.OOE+00 4.64E-11 5.43E-10 4.61E-09 75
r r
r r
t r
r r
r r
r r
r TABLE 249
- 4 QUARTER 2004 BATCH + CONTINUOUS RELEASES ADULT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION 4.79E-10 O.OOE+00 2.95E-11 O.OOE+00 O.OOE+00 4.64E-11 3.49E-12 2.95E-ll EXPOSURE TO SOIL 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION 2.53E-09 O.OOE+00 6.21E-10 0.OOE+00 O.OOE+00 O.OOE+00 7.32E-11 6.21E-10 PRODUCE CONSUMPTION 1.37E-08 O.OOE+00 3.35E-09 O.OOE+00 O.OOE+00 O.OOE+00 3.95E-10 3.3SE-09 TOTAL 1.67E-08 O.00E+00 4.OOE-09 O.OOE+00 O.OOE+00 4.64E-11 4.71E-10 4.OOE-09 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION 4.79E-10 O.OOE+00 2.95E-11 O.OOE+00 O.OOE+00 4.64E-11 3.49E-12 2.95E-l1 EXPOSURE TO SOIL O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OE+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION 2.S3E-09 O.OOE+00 6.21E-10 O.OOE+00 O.OOE+00 O.OOE+00 7.32E-11 6.21E-10 PRODUCE CONSUMPTION 1.37E-08 O.0EE+00 3.35E-09 O.OE+00 O.OOE+00 O.OOE+00 3.95E-10 3.35E-09 MEAT CONSUMPTION 2.78E-10 0.OOE+00 6.82E-11 O.OOE+00 O.OOE+00 O.OOE+00 8.03E-12 6.82E-l1 TOTAL 1.69E-08 O.OOE+00 4.07E-09 O.OOE+00 O.OOE+00 4.64E-11 4.79E-10 4.07E-09 MILK COW MAXIMUM LOCATION AIR INHALATION 4.79E-10 0.OOE+00 2.95E-11 O.OOE+00 O.OOE+00 4.64E-11 3.49E-12 2.95E-l1 EXPOSURE TO SOIL 0.00E+00 O.OO0E+00 0.0E+0 O.OO0E+00 0.00E+00 0.OE+00 O.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 2.53E-09 O.OOE+00 6.21E-10 O.O0E+00 O.OQE+00 0.OOE+00 7.32E-11 6.21E-10 PRODUCE CONSUMPTION 1.37E-08 O.OOE+00 3.35E-09 O.OOE+00 O.OOE+00 O.OOE+00 3.95E-10 3.35E-09 MEAT CONSUMPTION 2.78E-10 0.OOE+00 6.82E-11 0.OOE+00 O.OOE+00 O.OOE+00 8.03E-12 6.82E-11 COW MILK CONSUMPTION 1.05E-09 0.OOE+00 2.56E-10 0.00E+00 0.OOE+00 0.00E+00 3.02E-11 2.56E-10 TOTAL 1.80E-08 0.00E+00 4.33E-09 0.00E+00 0.00E+00 4.64E-11 5.09E-10 4.33E-09 MILK GOAT MAXIMUM LOCATION AIR INHALATION 4.79E-10 0.00E+00 2.95E-11 0.00E+00 0.OOE+00 4.64E-11 3.49E-12 2.95E-11 EXPOSURE TO SOIL 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.O0E+00 LEAFY VEGETABLE CONSUMPTION 2.53E-09 0.OOE+00 6.21E-10 0.00E+00 0.00E+00 0.00E+00 7.32E-11 6.21E-10 PRODUCE CONSUMPTION 1.37E-08 0.OOE+00 3.35E-09 0.00E+00 0.00E+00 0.00E+00 3.95E-10 3.35E-09 MEAT CONSUMPTION 2.78E-10 0.00E+00 6.82E-11 0.00E+00 0.00E+00 0.00E+00 8.03E-12 6.82E-11 GOAT MILK CONSUMPTION 2.19E-09 0.OOE+00 5.39E-10 0.00E+00 0.00E+00 0.00E+00 6.34E-11 5.39E-10 TOTAL 1.91E-08 0.00E+00 4.61E-09 0.00E+00 0.00E+00 4.64E-11 5.43E-10 4.61E-09 76
r r
r r
r
(
r r
r
[
[
(
f r
r r
TABLE 2-50
- 4 QUARTER 2004 BATCH RELEASES TEEN DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION TOTAL 0.00E+00 0.OOE+00 0.00E+00
- 0. OOE+00 0.OOE+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00
- 0. OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. OOE+00 0.OOE+00 0.00E+00
- 0. OOE+00 0.00E+00
- 0. OOE+00 0.00E+00 0.00E+00
- 0. 00E+00 0.003+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.003+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION
- 0. OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00+00 0.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 77
r r
r r
r r
r r
r r
(
f fr TABLE 2-51
- 4 QUARTER 2004 CONTINUOUS RELEASES TEEN DOSES PROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.22E-10 O.OOE+00 3.23E-11 0.OOE+00 0.OOE+00 7.96E-11 3.70E-12 3.23E-11 EXPOSURE TO SOIL O.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION 1.82E-09 0.00E+00 4.49E-10 0.OOE+00 0.OOE+00 0.OOE+00 5.11E-11 4.49E-10 PRODUCE CONSUMPTION 1.93E-08 0.00E+00 4.76E-09 0.00E+00 0.00E+00 O.O0E+00 5.41E-10 4.76E-09 TOTAL 2.16E-08 0.OOE+00 5.24E-09 0.00E+00 0.OOE+00 7.96E-11 5.96E-10 5.24E-09 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.22E-10 0.00E+00 3.23E-11 0.00E+00 0.00E+00 7.96E-11 3.70E-12 3.23E-11 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 1.82E-09 0.00E+00 4.49E-10 0.00E+00 0.00E+00 0.00E+00 5.11E-11 4.49E-10 PRODUCE CONSUMPTION 1.93E-08 0.00E+00 4.76Z-09 0.OOE+00 0.00E+00 0.00E+00 5.41E-10 4.76E-09 MEAT CONSUMPTION 1.80E-10 0.00E+00 4.44E-11 O.OOE+00 O.OOE+00 0.00E+00 5.05E-12 4.44E-11 TOTAL 2.18E-08 0.00E+00 5.29E-09 0.00E+00 0.00E+00 7.96E-11 6.01E-10 5.29E-09 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.22E-10 0.OOE+00 3.23E-11 0.00E+00 0.00E+00 7.965-11 3.70E-12 3.23E-11 EXPOSURE TO SOIL O.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 1.82E-09 0.OOE+00 4.49E-10 0.OOE+00 0.00E+00 0.OOE+00 5.11E-11 4.49E-10 PRODUCE CONSUMPTION 1.93E-08 0.00E+00 4.76E-09 0.OOE+00 0.OOE+00 0.OOE+00 5.41E-10 4.76E-09 MEAT CONSUMPTION 1.80E-10 0.00E+00 4.44E-11 0.00E+00 0.OOE+00 0.00E+00 5.05E-12 4.44E-11 COW MILK CONSUMPTION 1.48E-09 0.OOE+00 3.65E-10 0.OOE+00 0.OOE+00 0.00E+00 4.15E-11 3.65E-10 TOTAL 2.33E-08 0.OOE+00 5.65E-09 0.00E+00 0.OOE+00 7.96E-11 6.43E-10 5.65E-09 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 5.22E-10 0.OOE+00 3.23E-11 0.OOE+00 0.00E+00 7.96E-11 3.70E-12 3.23E-11 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.ooe+00 o.00E+00 LEAFY VEGETABLE CONSUMPTION 1.82E-09 0.00E+00 4.49E-10 0.00E+00 0.00E+00 0.00E+00 5.11E-11 4.49E-10 PRODUCE CONSUMPTION 1.93E-08 0.OOE+00 4.76E-09 0.OOE+00 0.00E+00 0.OOE+00 5.41E-10 4.76E-09 MEAT CONSUMPTION 1.80E-10 0.OOE+00 4.44E-11 0.OOE+00 0.00E+00 0.00E+00 5.05E-12 4.44E-11 GOAT MILK CONSUMPTION 3.10E-09 0.00E+00 7.66E-10 0.00E+00 0.00E+00 0.OOE+00 8.71E-11 7.66E-10 TOTAL 2.49E-08 0.00E+00 6.06E-09 0.OOE+00 0.00E+00 7.96E-11 6.88E-10 6.06E-09 78
(
r r
r C
r
(
rI f
I f
r I r r
TABLE 2-52
- 4 QUARTER 2004 BATCH + CONTINUOUS RELEASES TEEN DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES)
AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION 5.22E-10 0.00E+00 1.82E-09 1.93E-08
- 0. 00E+00 0.00E+00 0.00E+00
- 0. OOE+00
- 3. 23E-11 0.00E+00 4.49E-10 4.76E-09 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 7.96E-11 0.00E+00 0.00E+00 0.00E+00 3.70E-12 0.00E+00 5.11E-11 5.41E-10 3.23E-11 0.00E+00 4.49E-10 4.76E-09 TOTAL 2.16E-08 0.00E+00 5.24E-09 0.00E+00 0.00E+00 7.96E-11 5.96E-10 5.24E-09 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION TOTAL MILK COW MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION 5.22E-10 0.00E+00 1.82E-09 1.93E-08 1.80E-10 0.00E+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 3.23E-11 0.00E+00 4.49E-10 4.76E-09 4.44E-11 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.96E-11 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.70E-12 0.00E+00 5.11E-11 5.41E-10 5.05E-12 3.23E-11 0.00E+00 4.49E-10 4.76E-09 4.44E-11 2.18E-08 0.00E+00 5.29E-09 0.00E+00 0.00E+00 7.96E-11 6.01E-10 5.29E-09
- 5. 22E-10 0.00E+00 1.82E-09
- 1. 93E-08 1.80E-10 1.48E-09 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.23E-11 0.00E+00 4.49E-10 4.76E-09 4.44E-11 3.65E-10 0.00E+00 0.00E+00 0.00E-00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.96E-11 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00 3.70E-12 0.00E+00 5.11E-11 5.41E-10 5.05E-12 4.15E-11 3.23E-11 0.00E+00 4.49E-10 4.76E-09 4.44E-11 3.65E-10 TOTAL MILK GOAT MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION TOTAL 2.33E-08 0.00E+00 5.65E-09 0.00E+00 0.00E+00 7.96E-11 6.43E-10 5.65E-09 5.22E-10 0.00E+00 1.82E-09 1.93E-08 1.80E-10 3.10E-09 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.23E-11 0.00E+00 4.49E-10 4.76E-09 4.44E-11 7.66E-10 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.96E-11 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00+E00 3.70E-12 0.00E+00 5.11E-11 5.41E-10 5.05E-12 8.71E-11 3.23E-11 0.00E+00 4.49E-10 4.76E-09 4.44E-11 7.66E-10 2.49E-08 0.00E+00 6.06E-09 0.00E+00 0.00E+00 7.96E-11 6.88E-10 6.06E-09 79
I r
fI r
r r
Ir r
r i r I f
r f
r TABLE 2-53
- 4 QUARTER 2004 BATCH RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION TOTAL 0.OOE+00 O. OOE+00 0.OOE+00 0.OOE+00 0.O0E+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00
- 0. OOE+00 0.OOE+00 O.00E+00 0.00E+00 0.00E+00
- 0. OOE+00 0.0OE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00 O. OOE+00
- 0. OOE+OO O.OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOEO00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION TOTAL MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION TOTAL MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION TOTAL 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 O. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.00E+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+o0 O. OOE+00
- 0. OOE+00
- 0. 00E+00 0.OOE+00 0.OOE+00 0.00E+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 O.OOE+00
- 0. OOE+00 O.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 0OE+00 O. OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOB+OO
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.00E+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+OO 0.OOE+00
- 0. 00E+00
- 0. OOE+00 0.OOE+00 0.00E+00 O.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 O. OOEO00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.0OE+00
- 0. OOE+00 0.OOE+00 O.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.OOE+00 0.OOE+00
- 0. OOE+00
- 0. OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 80
I r
(r r
- r.
r r
r r
r tr IIr r
r TABLE 2-54 N 4 QUARTER 2004 CONTINUOUS RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES)
AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 4.88E-10 0.OOE+00 3.11E-11 0.OOE+00 0.OOE+00 7.13E-11 1.66E-12 3.11E-11 EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 2.31E-09 0.OOE+00 5.85E-10 0.OOE+00 0.OOE+00 0.OOE+00 3.11E-11 5.85E-10 PRODUCE CONSUMPTION 3.32E-08 0.00E+00 8.41E-09 0.00E+00 0.00E+00 0.00E+00 4.47E-10 8.41E-09 TOTAL 3.60E-08 0.00E+00 9.03E-09 0.OOE+00 0.00E+00 7.13E-11 4.80E-10 9.03E-09 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 4.88E-10 0.00E+00 3.11E-11 0.00E+00 0.00E+00 7.13E-11 1.66E-12 3.11E-11 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 2.31E-09 0.OOE+00 5.85E-10 0.00E+00 0.OOE+00 0.OOE+00 3.11E-11 5.85E-10 PRODUCE CONSUMPTION 3.32E-08 0.OOE+00 8.41E-09 0.00E+00 0.OOE+00 0.00E+00 4.47E-10 8.41E-09 MEAT CONSUMPTION 2.32E-10 0.OOE+00 5.89E-11 0.00E+00 0.OOE+00 0.00E+00 3.13E-12 5.89E-11 TOTAL 3.62E-08 0.004E00 9.09E-09 0.00E+00 0.00E+00 7.13E-11 4.83E-10 9.09E-09 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 4.88E-10 0.00E+00 3.11E-11 0.00E+00 0.00E+00 7.13E-11 1.66E-12 3.11E-11 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 2.31E-09 0.00E+00 5.85E-10 0.OOE+00 0.00E+00 0.005+00 3.11E-11 5.85E-10 PRODUCE CONSUMPTION 3.32E-08 0.00E+00 8.41E-09 0.OOE+00 0.00E+00 0.OOE+00 4.47E-10 8.41E-09 MEAT CONSUMPTION 2.32E-10 0.00E+00 5.89E-11 0.OOE+00 0.OOE+00 0.00E+00 3.13E-12 5.89E-11 COW MILK CONSUMPTION 2.50E-09 0.00E+00 6.33E-10 0.00E+00 0.00E+00 0.00E+00 3.36E-11 6.33E-10 TOTAL 3.87E-08 0.00E+00 9.72E-09 0.00E+00 0.00E+00 7.13E-11 5.17E-10 9.72E-09 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 4.88E-10 0.00E+00 3.11E-11 0.00E+00 0.00E+00 7.13E-11 1.66E-12 3.11E-11 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 2.31E-09 0.00E+00 5.85E-10 0.00E+00 0.00E+00 0.00E+00 3.11E-11 5.05E-10 PRODUCE CONSUMPTION 3.32E-08 0.00E+00 8.41E-09 0.00E+00 O.00E+00 0.00E+00 4.47E-10 8.41B-09 MEAT CONSUMPTION 2.32E-10 0.00E+00 5.89E-11 0.00E+00 0.00E+00 0.OOE+00 3.13E-12 5.89E-11 GOAT MILK CONSUMPTION 5.24E-09 0.OOE+00 1.33E-09 0.00E+00 0.OOE+00 0.00E+00 7.06E-11 1.33E-09 TOTAL 4.15E-08 0.00E+00 1.04E-08 0.OOE+00 0.00E+00 7.13E-11 5.53E-10 1.04E-08 81
r r
r
(
r r
r r
r r
r I
r r
r TABLE 2-55
- 4 QUARTER 2004 BATCH + CONTINUOUS RELEASES CHILD DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION 4.88E-10 0.OOE+00 3.11E-11 0.OOE+00 0.OOE+00 7.13E-11 1.66E-12 3.11E-ll EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 2.31E-09 0.00E+00 5.85E-10 0.00E+00 0.OOE+00 0.OOE+00 3.11E-11 5.85E-10 PRODUCE CONSUMPTION 3.32E-08 0.OOE+00 8.41E-09 0.OOE+00 0.00E+00 0.OOE+00 4.47E-10 8.41E-09 TOTAL 3.60E-08 0.OOE+00 9.03E-09 0.OOE+00 0.OOE+00 7.13E-11 4.80E-10 9.03E-09 MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION 4.88E-10 0.OOE+00 3.11E-11 0.00E+00 0.OOE+00 7.13E-11 1.66E-12 3.11E-1l EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.OOE+00 O.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 2.31E-09 0.00E+00 5.85E-10 0.00E+00 0.OOE+00 0.00E+00 3.11E-11 5.85E-10 PRODUCE CONSUMPTION 3.32E-08 0.OOE+00 8.41E-09 0.OOE+00 0.OOE+00 0.00E+00 4.47E-10 8.41E-09 MEAT CONSUMPTION 2.32E-10 0.00E+00 5.89E-11 0.OOE+00 0.OOE+00 0.00E+00 3.13E-12 5.89E-11 TOTAL 3.62E-08 0.00E+00 9.09E-09 0.OOE+00 0.00E+00 7.13E-11 4.83E-10 9.09E-09 MILK COW MAXIMUM LOCATION AIR INHALATION 4.88E-10 0.00E+00 3.11E-11 0.OOE+00 0.00E+00 7.13E-11 1.66E-12 3.11E-1l EXPOSURE TO SOIL 0.00E400 0.00E+00 0.005+00 O.OOE+00 0.00+E00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 2.31E-09 0.00E+00 5.85E-10 0.00E+00 0.00E+00 0.00E+00 3.11E-11 5.85E-10 PRODUCE CONSUMPTION 3.32E-08 0.OOE+00 8.41E-09 0.00E+00 0.00E+00 0.00E+00 4.47E-10 8.41E-09 MEAT CONSUMPTION 2.32E-10 0.00E+00 5.89E-11 0.00E+00 0.00E+00 0.00E+00 3.13E-12 5.89E-11 COW MILK CONSUMPTION 2.50E-09 0.00E+00 6.33E-10 0.OOE+00 0.00E+00 0.00E+00 3.36E-11 6.33E-10 TOTAL 3.87E-08 0.00E+00 9.72E-09 0.OOE+00 0.00E+00 7.13E-11 5.17E-10 9.72E-09 MILK GOAT MAXIMUM LOCATION AIR INHALATION 4.88E-10 0.00E+00 3.11E-11 0.00E+00 0.OOE+00 7.13E-11 1.66E-12 3.11E-11 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 2.31E-09 0.00E+00 5.85E-10 0.00E+00 0.00E+00 0.00E+00 3.11E-11 5.85E-10 PRODUCE CONSUMPTION 3.32E-08 0.00E+00 8.41E-09 0.00E+00 0.00E+00 0.00E+00 4.47E-10 8.41E-09 MEAT CONSUMPTION 2.32E-10 0.00E+00 5.895-11 0.00E+00 0.00E+00 0.00E+00 3.13E-12 5.89E-11 GOAT MILK CONSUMPTION 5.24E-09 0.00E+00 1.33E-09 0.OOE+00 0.00E+00 0.00E+00 7.06E-11 1.33E-09 TOTAL 4.15E-08 0.00E+00 1.04E-08 0.00E+00 0.OOE+00 7.13E-11 5.53E-10 1.04E-08 82
r r
r r
r r
r r
r r
r r
r r
r TABLE 2-56
- 4 QUARTER 2004 BATCH RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00+E00 0.00E+00 0.00E+00 0.00E+00 0.00+E00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 O.OOE+00 PRODUCE CONSUMPTION O.00E+00 O.OOE+00 O.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 TOTAL 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.002+00 MEAT CONSUMPTION 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL 0.00E+00 0.OOEe00 O.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 O.00E+00 0.00E+00 0.002+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 PRODUCE CONSUMPTION 0.00E+00 0.00+E00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.0OE+00 COW MILK CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 TOTAL 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 0.00E+00 0.002+00 0.OOE+00 0.00E+00 0.00E+00 0.002+00 0.002+00 0.00E+00 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00+E00 PRODUCE CONSUMPTION 0.00E+00 0.00+E00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 GOAT MILK CONSUMPTION 0.00+E00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.002+00 0.00E+00 TOTAL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 83
r r
r r
r r
r r
(
[
[
r f
f TABLE 2-57
- 4 QUARTER 2004 CONTINUOUS RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
TOTAL EXPOSURE LOCATION AND PATHWAY BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN (NORTH SECTOR AT 663. METERS)
AIR INHALATION 1.98E-10 0.OOE+00 1.25E-11 0.00E+00 0.OOE+00 5.43E-11 6.33E-13 1.25E-11 EXPOSURE TO SOIL 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.00E+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 TOTAL 1.98E-10 0.00E+00 1.25E-11 0.OOE+00 0.OOE+00 5.43E-11 6.33E-13 1.25E-11 MEAT ANIMAL (NORTH SECTOR AT 663. METERS)
AIR INHALATION 1.98E-10 0.OOE+00 1.25E-11 0.OOE+00 0.OOE+00 S.43E-11 6.33E-13 1.25E-11 EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 MEAT CONSUMPTION 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 TOTAL 1.98E-10 0.00E+00 1.25E-11 0.005+00 0.00E+00 5.43E-11 6.33E-13 1.25E-11 MILK COW (NORTH SECTOR AT 663. METERS)
AIR INHALATION 1.98E-10 0.00E+00 1.25E-11 0.00E+00 0.00E+00 5.43E-11 6.33E-13 1.25E-11 EXPOSURE TO SOIL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.005+00 0.00E+00 0.00.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 PRODUCE CONSUMPTION 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MEAT CONSUMPTION 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 COW MILK CONSUMPTION 2.72E-09 0.00E+00 6.91E-10 0.00E+00 0.00E+00 0.00E+00 3.39E-11 6.91E-10 TOTAL 2.91E-09 0.OOE+00 7.04E-10 0.00E+00 0.00E+00 5.43E-11 3.45E-11 7.04E-10 MILK GOAT (NORTH SECTOR AT 663. METERS)
AIR INHALATION 1.98E-10 0.00E+00 1.25E-11 0.00E+00 0.00E+00 5.43E-11 6.33E-13 1.25E-11 EXPOSURE TO SOIL 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 O.OOE+00 LEAFY VEGETABLE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 PRODUCE CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 0.OOE+00 MEAT CONSUMPTION 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 GOAT MILK CONSUMPTION 5.70E-09 0.00E+00 1.45E-09 0.OOE+00 0.00E+00 0.00E+00 7.12E-11 1.45E-09 TOTAL 5.90E-09 0.00E+00 1.46E-09 0.OOE+00 0.00E+00 5.43E-11 7.18E-11 1.46E-09 84
f f
r f
r f r r I
r rf I
[
TABLE 2-58
- 4 QUARTER 2004 BATCH + CONTINUOUS RELEASES INFANT DOSES FROM GASEOUS EFFLUENTS (EXCLUDING NOBLE GASES) AT MAXIMUM OFFSITE EXPOSURE LOCATIONS (MREM)
EXPOSURE LOCATION AND PATHWAY TOTAL BONE LIVER BODY THYROID KIDNEY LUNG GI-LLI SKIN GARDEN MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION 1.98E-10
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00 1.25E-11
- 0. OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+00
- 0. OOE+O0
- 0. OOE+00 0.OOE+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 5.43E-11 0.OOE+00
- 0. OOE+00
- 0. OOE+00 6.33E-13
- 0. OOE+00 0.OOE+00 0.OOE+00 1.25E-11
- 0. OOE+00 0.OOE+O0 0.OOE+00 TOTAL MEAT ANIMAL MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION 1.98E-10 O.OOE+00 1.25E-11 0.00E+00 0.00E+00 5.43E-11 6.33E-13 1.25E-11 1.98E-10
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00 0.OOE+00
- 0. OOE+00 o.00E+00 0.00E+00 1.25E-11 0.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 0.OOE+00
- 0. 00E+00
- 0. OOE+00
- 0. OOE+00
- 0. 00E+00 0.00E+00 0.00E+00 0.00E+00 5.43E-11 o.00E+00
- 0. 00E+00
- 0. 00E+00
- 0. OOE+00 6.33E-13 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00
- 1. 25E-11 0.00E+00 0.00E+00 0.00E+00
- 0. 00E+00 TOTAL MILK COW MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION COW MILK CONSUMPTION TOTAL 1.98E-10 0.00E+00 1.25E-11 0.00E+00 0.00E+00 5.43E-11 6.33E-13 1.25E-11
- 1. 98E-10
- 0. 00E+00 0.00E+00 0.00E+00 0.OOE+00 2.72E-09
- 0. OOE+00 0.OOE+00 0.00E+00 o.00E+00 0.00E+00 0.00B+00 1.25E-ll o.00E+00
- 0. OOE+00 0.00E+00 0.00E+00 6.91E-10 o.00Et00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 o.00E+00
- 0. OOE+00 0.00E+00
- 0. OOE+00
- 5. 43E-11 0.00E+00 o.OOE+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 6.33E-13
- 0. 00E+00 o.OOE+00 0.00E+00 0.00E+00 3.39E-11 1.25E-11
- 0. OOE+00
- 0. OOE+00 0.OOE+00 0.00E+00 6.91E-10 2.91E-09 0.OOE+00 7.04E-10 0.00E+00 0.00E+00 5.43E-11 3.45E-11 7.04E-10 MILK GOAT MAXIMUM LOCATION AIR INHALATION EXPOSURE TO SOIL LEAFY VEGETABLE CONSUMPTION PRODUCE CONSUMPTION MEAT CONSUMPTION GOAT MILK CONSUMPTION 1.98E-10 0.00E+00 0.00E+00
- 0. OOE+00
- 0. 00E+00 5.70E-09
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00 0.00E+00
- 0. 00E+00 1.25E-11
- 0. 00E+00 0.00E+00 0.00E+00
- 0. 00E+00 1.45E-09 0.00E+00 0.00E+00
- 0. 00E+00
- 0. OOE+00
- 0. 00E+00
- 0. 00E+00 0.00E+00 5.43E-ll 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 6.33E-13 0.00E+00 0.00E+00
- 0. OOE+00 0.008+00 7.12E-11 1.25E-11 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 1.45E-09 TOTAL 5.90E-09 0.00E+00 1.46E-09 0.00E+00 0.00E+00 5.43E-11 7.18E-11 1.46E-09 85
r r
r r
r t
r r
r I
I f
r f
I I
r TABLE 2-59 FIRST QUARTER 2004 BATCH + CONTINUOUS RELEASES POPULATION DOSE (50-MILE) FROM GASEOUS EFFLUENTS (MAN-REM)
EXPOSURE PATHWAY TOTAL BODY THYROID AIR SUBMERSION 0.OE+00 O.OE+00 AIR INHALATION 0.OE+00 0.OE+00 EXPOSURE TO SOIL 0.OE+00 0.OE+00 LEAFY VEGETABLE CONSUMPTION 0.OE+00 0.OE+00 PRODUCE CONSUMPTION 0.OE+00 0.OE+00 MEAT CONSUMPTION 0.OE+00 0.OE+00 MILK CONSUMPTION 0.OE+00 0.OE+00 TOTAL 0.OE+00 0.OE+00 AVERAGE DOSE (MREM/PERSON) 0.0E+00 0.0E+00 86
r r
r I r r
r r
f r
TABLE 2-60 SECOND QUARTER 2004 BATCH + CONTINUOUS RELEASES POPULATION DOSE (50-MILE)
FROM GASEOUS EFFLUENTS (MAN-REM)
EXPOSURE PATHWAY TOTAL BODY THYROID AIR SUBMERSION 0.OE+00 O.OE+00 AIR INHALATION 0.OE+00 0.OR+00 EXPOSURE TO SOIL 0.OE+00 0.OE+00 LEAFY VEGETABLE CONSUMPTION 0.OE+00 0.OE+00 PRODUCE CONSUMPTION 0.OE+00 0.OE+00 MEAT CONSUMPTION 0.OE+00 0.OE+00 MILK CONSUMPTION O.OE+00 O.OE+00 TOTAL 0.OE+00 0.OE+00 AVERAGE DOSE (MREM/PERSON) 0.OE+00 0.OE+00 87
r r
r r
r r
r
(
F r I
r r
TABLE 2-61 THIRD QUARTER 2004 BATCH + CONTINUOUS RELEASES POPULATION DOSE (50-MILE)
FROM GASEOUS EFFLUENTS (MAN-REM)
EXPOSURE PATHWAY TOTAL BODY THYROID AIR SUBMERSION 0.OE+00 0.OE+00 AIR INHALATION 2.OE-10 0.OE+00 EXPOSURE TO SOIL 4.2E-10 4.2E-10 LEAFY VEGETABLE CONSUMPTION 7.1E-11 0.OE+00 PRODUCE CONSUMPTION 3.8E-10 0.OE+00 MEAT CONSUMPTION 6.6E-11 0.OE+00 MILK CONSUMPTION 1.2E-09 0.OE+00 TOTAL 2.3E-09 4.2E-10 AVERAGE DOSE (MREM/PERSON) 1.1E-12 2.OE-13 88
r r
f r
r r
I f
r I I
I I
I r
f TABLE 2-62 FOURTH QUARTER 2004 BATCH + CONTINUOUS RELEASES POPULATION DOSE (50-MILE) FROM GASEOUS EFFLUENTS (MAN-REM)
EXPOSURE PATHWAY TOTAL BODY THYROID AIR SUBMERSION 0.OE+00 0.OE+00 AIR INHALATION 1.8E-10 O.OE+00 EXPOSURE TO SOIL 0.OE+00 O.OE+00 LEAFY VEGETABLE CONSUMPTION 6.6E-11 0.OE+00 PRODUCE CONSUMPTION 3.5E-10 O.OE+00 MEAT CONSUMPTION 5.7E-11 O.OE+00 MILK CONSUMPTION 8.9E-10 0.OE+00 TOTAL 1.5E-09 0.OE+00 AVERAGE DOSE (MREM/PERSON) 7.5E-13 O.OE+00 89
- 3. METEOROLOGICAL DATA Meteorological models and assumptions used in performing the analyses are presented in PGE-1021, "Offsite Dose Calculation Manual."
90
- 4. CHANGES TO THE OFFSITE DOSE CALCULATION MANUAL (ODCM)
Requirement The Offsite Dose Calculation Manual is no longer required by Trojan Facility Operating License NPF-1, Appendix A, Permanently Defueled Technical Specifications, to be submitted as part of, or concurrent with, the Annual Radioactive Effluent Release Report. The ODCM is submitted with, or as part of, the Radiological Environmental Monitoring Report in accordance with PGE-8010, Quality Assurance Program, Appendix C, Section 1.5.1.2.
91
- 5. ASSESSMENT OF DOSES WVITHIN THE UNRESTRICTED AREA BOUNDARY An assessment of doses to individuals utilizing controlled areas within the Trojan Nuclear Plant Site Exclusion Area Boundary was performed for 2004. Specific locations considered included occupational areas outside the restricted area boundary and recreational (i.e., public access) areas located at the site. The methodology contained in Appendix D of PGE-1021, 'Offsite Dose Calculation Manual (ODCM)," was followed. Occupancies of 2,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> per year for occupational locations, 1,530 hours0.00613 days <br />0.147 hours <br />8.763227e-4 weeks <br />2.01665e-4 months <br /> per year for recreational locations, and 2,496 hours0.00574 days <br />0.138 hours <br />8.201058e-4 weeks <br />1.88728e-4 months <br /> per year for the park host were assumed. Recreational activities (daytime only) are hiking, picnicking, swimming, fishing, and nature observation. Location directions and downwind distances are tabulated below:
TABLE 5-1 ONSITE DOSE LOCATIONS CONSIDERED ASSUMED OCCUPANCY DISTANCE OCCUPANCY FACTOR SECTOR (meters)
LOCATION (hours/year)
(hours/8760)
SSE 286 South Cooling Tower 1530 0.17 S
414 Sewage Plant 2000 0.23 SSW 305 Park 1530 0.17 SW 122 Administration Bldg.
2000 0.23 WSW 686 Visitor Center 1530 0.17 W
398 Warehouse 2000 0.23 WNW 300 Trojan North Bldg.
2000 0.23 SSW 1150 Park Host 2496 0.28 The methodology described in Appendix D of the ODCM allows for the use of a correction factor when performing an assessment of doses to individuals within the Unrestricted Area boundary. The correction factor is the highest ratio of the gamma air dose at a location within the Unrestricted Area boundary to the gamma air dose at the site boundary. Based on historical data, the highest correction factor for continuous releases is equal to 4.0. The gamma air dose for all locations within the Unrestricted Area boundary was determined by multiplying the gamma air dose at the site boundary by 4.0. This same methodology was also used to determine the beta air dose for all locations listed in Table 5-1.
The gamma and beta air dose within the Unrestricted Area boundary is given in Table 5-2.
92
TABLE 5-2 GAMMA AND BETA AIR DOSE Ouarter Gamma Air Dose (mrad)
Beta Air Dose (mrad)
First O.OOE+00 O.OOE+00 Second O.OOE+00 O.OOE+00 Third O.OOE+00 O.OOE+00 Fourth O.OOE+00 O.OOE+00 93
- 6. DIRECT RADIATION DOSES FROM THE FACILITY Controlled/Unrestricted Area Thermoluminescent Dosimeter (TLD) measurements are used to assess the impact of operational activities of the Trojan Nuclear Plant on ambient radiation levels. For sources of direct radiation from the facility, TLD measurements indicate that total body doses to individuals in Unrestricted Areas are zero.
Trojan Nuclear Plant permits members of the public to have access to controlled areas of the site.
Therefore, an assessment of the dose to a member of the public in the Controlled Area during 2004 was performed.
The highest dose rates during the year were measured at the North Industrial Area fence adjacent to the Independent Spent Fuel Storage Installation (ISFSI). The yearly average dose rate at this location was 2.05 millirem/day above background.
The North Industrial Area fence is considered accessible to members of the public. Therefore, a prospective evaluation of the area was performed to establish occupancy. It was determined that a member of the public would not occupy this area for more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in a year. Therefore, the annual dose to a member of the public, due to his or her activities in the Controlled Area, is conservatively calculated to be 2.05 millirem.
94
ATTACHMENT 1 SOLID WASTE SHIPPED OFFSITE FOR DISPOSAL AND ESTIMATES OF MAJOR NUCLIDES BY WASTE CLASS AND STREAM FROMN JANUARY 1, 2004 TO DECEMBER 30, 2004
NRC Regulatory Guide 1.21 Reports Page Report Date:
1/11/2005 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2004 to 06/3012004 Percent Cutoff:
0 Resins, Filters, an Evap Boom Waste Class A
_Nudlide Name Percent Abundance Curies H-3 0.091%
4.49E-04 UC-14 0.058%
2.88E-04 Mn-54 0.001%
5.71 E-06 Fe-55 6.516%
3.21 E-02 CO-57 0.001%
2.76E-06 Co-60 36.087%
1.78E-01 Ni-63 37.799%
1.86E-01 Sr-90 0.686%
3.38E-03 Nb-94 0.025%
1.23E-04 Sb-125 0.050%
2.44E-04 Cs-134 0.429%
2.11E-03 Cs-1 37 16.257%
8.00E-02 Ce-144 0.003%
1.72E-05 U-233 0.000%
2.89E-07 Pu-238 0.038%
1.86E-04 Pu-239 0.036%
1.79E-O4 Pu-241 1.858%
9.14E-03 Ar-241 0.036%
1.78E-04 Cm-242 0.000%
3.10E-07 Cm-243 0.028%
1.39E-04 Resins, Filters, and Evap Bottom Waste Class All Nuclide Name Percent Abundance Curies H-3 0.091%
4.49E-04 C-14 0.058%
2.88E-04 Mn-54 0.001%
5.71 E-06 Fe-55 6.516%
3.21 E-02 Co-57 0.001%
2.76E-06 Co-60 36.087%
__1.78E-01 Ni-63 37.799%
1.86E-01 Sr-90 0.686%
3.38E-03 Nb-94 0.025%
1.23E-04 Sb-125 0.050%
2.44E-04 Cs-134 0.429%
8.00E-02 Ce-144 0.003%
1.72E-05 U-233 0.000%
2.89E-07 Pu-238 0.038%
i.86E-04 Pu-239 0.036%
1.79E-04 Pu-241 1.858%
9.14E-03 Am-241 0.036%
1.78E-04 Cm-242 0.000%
3.10E-07 Cm-243 0.028%
1.39E-04 Dry Active Waste Waste Class A
NRC Regulatory Guide 1.21 Reports Page 2
Report Date:
1/11/2005 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/0112004 to 06/30/2004 Percent Cutoff:
0 Nuclide Name Percent Abundance Curies H-3 0.092%
4.70E-04 C-14 0.100%
5.11E-04 Mn-54 0.000%
2.51 E-06 Fe-55 3.672%
1.88E-02 Co-57 0.000%
4.43E-02 Ni-63 23.074%
1.18E-01 Sr-90 0.232%
1.19E-03 Nb-94 0.016%
8.19E-05 Ru-i 06 0.150%
7.67E-04 Ag-110m 0.000%
3.24E-07 Sb-1 25 0.072%
3.70E-04 Cs-134 0.005%
2.51 E-05 Cs-I 37 62.333%
3.18E-01 Ce-144 0.000%
6.OOE-07 Eu-155 0.006%
3.06E-05 Pu-238 0.020%
1.01 E-04 Pu-239 0.021%
1.08E-04 Pu-241 1.491%
7.62E-03 Am-241 0.025%
1.29E-04 Cm-242 0.000%
3.41 E-I 1 Cm-243 0.017%
8.79E-05 Dry Active Waste Waste Class All Nuclide Name Percent Abundance Curies H-3 0.092%
4.70E-04 C-14 0.100%
5.11E-04 Mn-54 0.000%
2.51 E-06 Fe-55 3.672%
1.88E-02 Co-57 0.000%
1.47E-07 Co-60 8.671%
4.43E-02 Ni-63 23.074%
1.18E-01 Sr-90 0.232%
1.19E-03 Nb-94 0.016%
8.19E-05 Ru-106 0.150%
7.67E-04 Ag-110m 0.000%
3.24E-07 Sb-125 0.072%
3.70E-04 Cs-1 34 0.005%
2.51 E-05 Cs-1 37 62.333%
3.18E-01 Ce-144 0.000%
6.OOE-07 Eu-155 0.006%
3.06E-05 Pu-238 0.020%
1.01 E-04 Pu-239 0.021%
I.08E-04 Pu-241 1.491%
7.62E-03 Am-241 0.025%
1.29E-04 Cm-242 0.000%
3.41 E-1 I Cm-243 0.017%
8.79E-05 Other Waste
NRC Regulatory Guide 1.21 Reports Page 3
Report Date:
1111/2005 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/0112004 to 06/30/2004 Percent Cutoff:
0 Waste Class C Nuclide Name Percent Abundance Curies H-3 0.109%
2.91 E-04 Co-60 0.008%
2.13E-05 Kr-85 1.717%
4.59E-03 Sr-90 21.033%
5.63E-02 Ru-106 0.451%
1.21 E-03 Sb-125 0.352%
9.41 E-04 Te-125m 0.046%
1.22E-04 1-129 0.000%
3.24E-08 Cs-134 3.066%
8.21 E-03 Cs-137 32.543%
8.71 E-02 Ce-144 0.117%
3.12E-04 Pm-147 4.772%
1.28E-02 Eu-154 1.277%
3.42E-03 Eu-155 0.303%
8.10E-04 Pu-238 1.209%
3.24E-03 Pu-239 0.102%
2.74E-04 Pu-240 0.189%
5.06E-04 Pu-241 30.674%
8.21 E-02 Am-241 0.598%
1.60E-03 Cm-244 1.434%
3.84E-03 Other Waste Waste Class All Nuclide Name Percent Abundance Curies H-3 0.109%
2.91E-04 Co-60 0.008%
2.13E-05 Kr-85 1.717%
4.59E-03 Sr-90 21.033%
5.63E-02 Ru-2106 0.451%
1.21 E-03 Sb-125 0.352%
9.41E-04 Te-125m 0.046%
1.22E-04 I-129 0.000%
3.24E-08 Cs-134 3.066%
8.21E-03 Cs-137 32.543%
8.71 E-02 Ce-144 0.117%
3.12E-04 Pm-147 4.772%
1.28E-02 Eu-154 1.277%
3A42E-03 Eu-155 0.303%
- 8. 10E-04
_Pu-238 1.209%
3.24E-03
_Pu-239 0.102%
2.74E-04 Pu-240 0.189%
5.06E-04 Pu-241 30.674%
8.21 E402 Am-241 0.598%
1.60E-03
=Cm-244 1.434%
3.84E-03 Sum of All 4 Categories Waste Class A Nuclide Name Percent Abundance Curies H-3 0.092%
9.18E-04
NRC Regulatory Guide 1.21 Reports Page 4
Report Date:
1/11/2005 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2004 to 06/30/2004 Percent Cutoff:
0 C-14 0.080%
7.99E-04 Mn-54 0.001%
8.22E-06 Fe-55 5.068%
5.08E-02 Co-57 0.000%
2.91 E-06 Co-60 22.124%
2.22E-01 Ni-63 30.300%
3.04E-01 Sr-90 0.455%
4.56E-03 Nb-94 0.020%
2.05E-04 Ru-106 0.076%
7.67E-04 Ag-11 Om 0.000%
3.24E-07 Sb-125 0.061%
6.14E-04 Cs-134 0.213%
2.14E-03 Cs-137 39.725%
3.98E-01 Ce-144 0.002%
1.78E-05 Eu-155 0.003%
3.06E-05 U-233 0.000%
2.89E-07 Pu-238 0.029%
2.87E-04 Pu-239 0.029%
2.86E-04 Pu-241 1.671%
1.68E-02 Am-241 0.031%
3.07E-04 Cm-242 0.000%
3.10E-07 Cm-243 0.023%
2.27E-04 Sum of All 4 Categories Waste Class C Nuclide Name Percent Abundance Curies H-3 0.109%
2.91E-04 Co-60 0.008%
2.13E-05 Kr-85 1.717%
4.59E-03 Sr-90 21.033%
5.63E-02 Ru-106 0.451%
1.21E-03 S-125 3
0.352%
9.41 E-04 Te-125m 0.046%
1.22E-04 I-129 0.000%
3.24E-08 Cs-134 3.066%
8.21 E-03 Cs-1 37 32.543%
_8.71 E-02 Ce-144 0.11 7%
3.12E-04 Pm-147 4.772%
1.28E-02 Eu-1 54 1.277%
3.42E-03 Eu-155 0.303%
8.10E-04 Pu-238 1.209%
3.24E-03 Pu-239 0.102%
2.74E-04 Pu-240 0.189%
5.06E-04 Pu-241 30.674%
8.21 E-02 Am-241 0.598%
1.60E-03 Cm-244 1.434%
3.84E-03 Sum of All 4 Categories Waste Class All Nuclide Name Percent Abundance Curies H-3 0.095%
1.21 E-03
NRC Regulatory Guide 1.21 Reports Page 5
Report Date:
1/11/2005 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2004 to 06/30/2004 Percent Cutoff:
0 C-14 0.063%
7.Q9E-04 Mn-54 0.001%
8.22E-06 Fe-55 4.000%
5.08E-02 Co-57 0.000%
2.91 E-06 Co-60 17.466%
2.22E-01 Ni-63 23.918%
3.04E-01 Kr-85 0.362%
4.59E-03 Sr-90 4.789%
6.09E-02 Nb-94 0.016%
2.05E-04 Ru-106 0.155%
1.97E-03 Ag-11 Om 0.000%
3.24E-07 Sb-1125 0.122%
1.55E-03 Te-125m 0.010%
1.22E-04 C-129 0.000%
3.24E-08 Cs-1 34 0.814%
1.03E-02 Cs-137 38.212%
4.86E-01 Ce-144 0.026%
3.30E-04 Pm-147 1.005%
1.28E-02 Eu-154 0.269%
3.42E-03 Eu-155 0.066%
8.41 E-04 U-233 0.000%
2.89E-07 Pu-238 0.277%
3.52E-03 Pu-239 0.044%
5.60E-04 Pu-240 0.040%
5.06E-04 Pu-241 7.780%
9.88E-02 Am-241 0.150%
1.91 E-03 Cm-242 0.000%
3.10E-07 Cm-243 0.018%
2.27E-04 Cm-244 0.302%
3.84E-03
NRC Regulatory Guide 1.21 Reports Page Report Date:
1J11/2005 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 07/01/2004 to 12/30/2004 Percent Cutoff:
0 Dry Active Waste Waste Class A Nuclide Name Percent Abundance Curies H-3 0.196%
1.24E-04 C-14 0.271%
1.72E-04 Mn-54 0.002%
1.03E-06 Fe-55 8.923%
5.67E-03 Co-57 0.000%
2.98E-08 Co-60 19.723%
1.25E-02 Ni-63 61.526%
3.91 E-02 Sr-90 0.620%
3.94E-04 Nb-94 0.012%
7.38E-06 Ru-106 0.009%
5.66E-06 Ag-110m 0.000%
1.48E-07 Sb-125 0.223%
1.42E-04 Cs-134 0.018%
1.15E-05 Cs-137 3.812%
2.42E-03 Ce-144 0.000%
2.41E-07 Eu-155 0.022%
1.40E-05 Pu-238 0.056%
3.58E-05 Pu-239 0.059%
3.74E-05 Pu-241 4.447%
2.82E-03 Am-241 0.048%
3.08E-05 Cm-242 0.000%
3.40E-12 Cm-243 0.032%
2.05E-05 Dry Active Waste Waste Class All Nuclide Name Percent Abundance Curies H-3 0.196%
1.24E-04 C-14 0.271%
1.72E-04 Mn-54 0.002%
1.03E-06 Fe-55 8.923%
5.67E-03 Co-57 0.000%
2.98E-08 Co-60 19.723%
1.25E-02 Ni-63 61.526%
3.91 E-02 Sr-90 0.620%
3.94E-04 Nb-94 0.012%
7.38E-06 Ru-106 0.009%
5.66E-06 Aa-110m 0.000%
1.48E-07 Sb-125 0.223%
1.42E-04 Cs-134 0.018%
1.15E-05 Cs-I 37 3.812%
2.42E-03 Ce-144 0.000%
2.41 E-07 Eu-155 0.022%
1.40E-05 Pu-238 0.056%
3.58E-05 Pu-239 0.059%
3.74E-05 Pu-241 4.447%
2.82E-03 Am-241 0.048%
3.08E-05 Cm-242 0.000%
3.40E-12
NRC Regulatory Guide 1.21 Reports Page 2
Report Date:
1/11/2005 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 07/01/2004 to 12/30/2004 Percent Cutoff:
0 Cm-243 0.032%
2.05E-05 Other Waste Waste Class A Nuclide Name Percent Abundance Curies H-3 0.000%
9.61 E-09 C-14 0.000%
9.56E-08 Fe-55 0.003%
3.04E-06 Co-60 0.006%
6.49E-06 Ni-63 0.021%
2.16E-05 Sr-90 0.000%
3.36E-08 Tc-99 0.000%
2.06E-07 Ru-106 0.000%
5.46E-10 Cs-I 37 99.969%
1.03E-01 Ce-144 0.000%
2.25E-1 I Pu-238 0.000%
3.13E-09 Pu-239 0.000%
4.79E-09 Pu-241 0.000%
2.51 E-07 Am-241 0.000%
2.59E-07 Cm-243 0.000%
1.47E-09 Other Waste Waste Class All Nuclide Name Percent Abundance Curies H-3 0.000%
9.61 E-09 C-14 0.000%
9.56E-08 Fe-55 0.003%
3.04E-06 Co-60 0.006%
6.49E-06 Ni-63 0.021%
2.16E-05 Sr-90 0.000%
3.36E-08 Tc-99 0.000%
2.06E-07 Ru-106 0.000%
5.46E-10 Cs-137 99.969%
1.03E-01 Ce-144 0.000%
2.25E-1 1 Pu-238 0.000%
3.13E-09 Pu-239 0.000%
4.79E-09 Pu-241 0.000%
2.51 E-07 Arn-241 0.000%
2.59E-07 Cm-243 0.000%
1.47E-09 Sum of All 4 Categories Waste Class A Nuclide Name Percent Abundance Curies H-3 0.075%
1.24E-04 C-14 0.103%
1.72E-04 Mn-54 0.001%
1.03E-06 Fe-55 3.408%
5.67E-03 Co-57 0.000%
2.98E-08 Co-60 7.533%
1.25E-02 Ni-63 23.499%
3.91 E-02 Sr-90 0.237%
3.94E-04
NRC Regulatory Guide 1.21 Reports Page 3
Report Date:
1/1112005 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 07/01/2004 to 12/30/2004 Percent Cutoff:
0 Nb-94 0.004%
7.38E-06 Tc-99 0.000%
2.06E-07 Ru-1 06 0.003%
5.66E-06 Ag-110m 0.000%
1.48E-07 Sb-125 0.085%
1.42E-04 Cs-134 0.007%
1.15E-05 Cs-137 63.263%
1.05E-01 Ce-144 0.000%
2.41 E-07 Eu-155 0.008%
1.40E-05 Pu-238 0.022%
3.S8E-05 Pu-239 0.022%
3.74E-05 Pu-241 1.698%
2.83E-03 Am-241 0.019%
3.1OE-05 Cm-242 0.000%
3.40E-12 Cm-243 0.012%
2.05E-05 Sum of All 4 Categories Waste Class All Nuclide Name Percent Abundance Curies H-3 0.075%
1.24E-04 C-14 0.103%
1.72E-04 Mn-54 0.001%
1.03E-06 Fe-55 3.408%
5.67E-03 Co-57 0.000%
2.98E-08 Co-60 7.533%
1.25E-02 Ni-63 23.499%
3.91 E-02 Sr-90 0.237%
3.94E-04 Nb-94 0.004%
7.38E-06 Tc-99 0.000%
2.06E-07 Ru-106 0.003%
5.66E-06 Ag-1 Om 0.000%
1.48E-07 Sb-125 0.085%
1.42E-04 Cs-134 0.007%
1.15E-05 Cs-137 63.263%
1.05E-01 Ce-144 0.000%
2.41 E-07 Eu-155 0.008%
1.40E-05 Pu-238 0.022%
3.58E-05 Pu-239 0.022%
3.74E-05 Pu-241 1.698%
2.83E-03 Am-241 0.019%
3.10E-05 Cm-242 0.000%
3.40E-12 Cm-243 0.012%
2.05E-05