Text
U.S. Department of Homeland Security Region V 536 South Clark Street, Floor 6 Chicago, IL 60605 a
FEMA October 1, 2004 Mr. Tim McGinty, Chief Inspection and Communications Section (EPPO-A)
Emergency Preparedness Project Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop: 06 H2 Washington, DC 20555-0001
Dear Mr. McGinty:
Enclosed is the Final Report for the Radiological Emergency Preparedness (REP) Plume Pathway Exercise conducted on July 21, 2004 for the Quad Cities Generating Station.
There were no Deficiencies. There were no Areas Requiring Corrective Action (ARCAs). There were no prior unresolved ARCAs to be resolved during this exercise.
Based on the results of the July 21, 2004 exercise, the offsite radiological emergency response plans and preparedness for the State of Illinois, and Rock Island and Whiteside Counties, site-specific to the Quad Cities Generating Station, can be implemented. These plans are adequate to provide reasonable assurance that appropriate measures can be taken offsite to protect the health and safety of the public.
Therefore, Title 44 CFR, Part 350, approval of the offsite radiological emergency response plans and preparedness for the State of Illinois, and Rock Island and Whiteside Counties, granted on March 2, 1984, remains in effect. Copies of this report were transmitted to the Nuclear Regulatory Commission's (NRC) Region III Office, the Department of Homeland Security/FEMA National Office, and the State of Illinois.
If you have any questions, please let me know or have a member of your staff contact William King at (312) 408-5575.
Sincerely, Regional Director Enclosure IvIvIfma.gov
K-I:
A.3
'1
.3.
-IJ I
A
- J Final IE rse Repr Quad Cities -i-enera'ting' Station Licensee:
-xelon
-11 '
J -
3-J 1
Exercise Dati Report Date:
July 21, 2004 September 30,2004 U.S. DEPARTMEN )F HOMELAND SECURITY FEtGION V
-536 South V&k Street, 6th Floor Chicago,-nois 60605-1521 Jc
TABLE OF CONTENTS L
Page I.
EXECUTIVE
SUMMARY
1 L
II.
INTRODUCTION...............................................................................................................2 III.
EXERCISE OVERVIEW....................................................................................................4 A.
Plume Emergency Planning Zone Description.....................................
4 B.
Exercise Participants......................................
4 C.
Exercise Timeline......................................
5 IV.
EXERCISE EVALUATION AND RESULTS....................................
7 A.
Summary Results of Exercise Evaluation......................................
7 B.
Status of Jurisdictions Evaluated......................................
9
- 1.
STATE OF ILLINOIS.....................................
11 L
1.1 Initial Warning Point........................................
11 1.2 State Emergency Operations Center.......................................
11 1.3 Radiological Emergency Assessment Center................................ 11 1.4 State Forward Command Post.......................................
11 1.5 Traffic and Access Control Point.......................................
12 L
1.6 Emergency Operations Facility.......................................
12 1.7 Joint Public Information Center.......................................
12 L
1.8 Monitoring and Decontamination of Evacuees and Emergency Workers, and Registration of Evacuees........................................ 13 1.9 Monitoring and Decontamination of Emergency Worker Equipment.......................................
13 1.10 Temporary Care of Evacuees.......................................
13 1.11 IEMA Liaison in Rock Island County EOC.................................. 14 L
1.12 IEMA Liaison in Whiteside County EOC..................................... 14
- 2.
RISK JURISDICTIONS.14 2.1 ROCK ISLAND COUNTY.14 2.1.1 Initial Notification Point.14 2.1.2 County Emergency Operations Center.15 2.1.3 Local Media Briefing.15 i
2.1.4 Traffic and Access Control Point....................................... 15 2.1.5 EBS Radio Station WKBF/WiLTS AM/FM...................... 16 L
2.2 WHITESIDE COUNTY.........................................
16 2.2.1 Initial Notification Point.........................................
16 2.2.2 County Emergency Operations Center.............................. 16 2.2.3 Local Media Briefing.........................................
17 2.2.4 Traffic and Access Control Point....................................... 17 L
2.2.5 EBS Radio Station WSDR/WZZT/WSSQ AM/FM.......... 17 2.2.6 Riverbend Community Unit School District #2................ 18 List of Appendices APPENDIX 1 - ACRONYMS AND ABBREVIATIONS.19 APPENDIX 2 - EXERCISE EVALUATORS AND TEAM LEADERS.21 APPENDIX 3 - EXERCISE CRITERIA AND EXTENT-OF-PLAY AGREEMENT.23 APPENDIX 4 - EXERCISE SCENARIO.38 L
List of Tables.
L Table 1 -Exercise Timeline
.6 Table 2 - Summary Results of Exercise Evaluation
.8 LL ii
I.
EXECUTIVE
SUMMARY
On July 21, 2004, a partial participation exercise was conducted in the plume exposure pathway emergency planning zone (EPZ) around the Quad Cities Generating Station by the U.S. Department of Homeland Security/Federal Emergency Management Agency (DHS/FEMA), Region V. The purpose of the exercise was to assess the level of State and local preparedness in responding to a radiological emergency. This exercise was held in accordance with DHS/FEMA's policies and guidance concerning the exercise of State and local radiological emergency response plans (RERPs) and procedures.
The most recent exercise at this site was conducted on July 10, 2002. The qualifying emergency preparedness exercise was conducted on May 20, 1981.
DHS/FEMA wishes to acknowledge the efforts of the many individuals in the State of Illinois and the risk counties of Rock Island and Whiteside who participated in this exercise.
Protecting the public health and safety is the full-time job of some of the exercise participants and an additional assigned responsibility for others. Still others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities. The cooperation and teamwork of all the participants were evident during this exercise.
This final report contains the evaluation of the biennial exercise, including the following out-of-sequence activities: The Riverbend Community Unit School District #2 EV-2 Interview, and the Monitoring and Decontamination of Evacuees and Emergency Workers and Registration of Evacuees, Monitoring and Decontamination of Emergency Worker Equipment and Temporary Care of Evacuees at the Morrison High School.
State, Rock Island County and Whiteside County organizations demonstrated knowledge of their emergency response plans and procedures and adequately implemented them.
There were no Deficiencies or Areas Requiring Corrective Action (ARCAs) identified as a result of this exercise. There were no prior issues from the previous biennial exercise needing to be resolved.
Medical Services Drills are being conducted under a pilot program presented by the State of Illinois on May 5, 1999. The pilot program remains under evaluation.
1
II.
INTRODUCTION On December 7, 1979, the President directed FEMA to assume the lead responsibility for all offsite nuclear planning and response. DHS/FEMA's activities are conducted pursuant to 44 Code of Federal Regulations (CFR) Parts 350, 351 and 352. These regulations are a key element in the Radiological Emergency Preparedness (REP)
Program that was established following the Three Mile Island Nuclear Station accident in March 1979.
FEMA Rule 44 CFR 350 establishes the policies and procedures for DHS/FEMA's initial and continued approval of State and local governments' radiological emergency planning and preparedness for commercial nuclear power plants. This approval is contingent, in part, on State and local governments' participation in joint exercises with licensees.
DHS/FEMA's responsibilities in radiological emergency planning for fixed nuclear facilities include the following:
Taking the lead in offsite emergency planning and in the review and evaluation of RERPs and procedures developed by State and local governments; Determining whether such plans and procedures can be implemented on the basis of the evaluation of exercises of the plans and procedures conducted by State and local governments; Responding to requests by the U.S. Nuclear Regulatory Commission (NRC) pursuant to the Memorandum of Understanding between the NRC and FEMA dated June 17, 1993 (Federal Register, Vol. 58, No. 176, September 14, 1993);
and Coordinating the activities of Federal agencies with responsibilities in the radiological emergency planning process:
U.S. Department of Commerce, U.S. Nuclear Regulatory Commission, U.S. Environmental Protection Agency, U.S. Department of Energy, U.S. Department of Health and Human Services U.S. Department of Transportation, U.S. Department of Agriculture, U.S. Department of the Interior, and U.S. Food and Drug Administration.
Representatives of these agencies serve on the DHS/FEMA Region V Regional Assistance Committee (RAC), which is chaired by DHS/FEMA.
2
Formal submission of the RERPs for the Quad Cities Generating Station to FEMA Region V by the State of Illinois and involved local jurisdictions occurred on December 15, 1982. Formal approval of these RERPs was granted by FEMA on March 2, 1984, under 44 CFR 350.
A REP exercise was conducted on July 21, 2004 by DHS/FEMA Region V to assess the capabilities of State and local offsite emergency preparedness organizations in implementing their RERPs and procedures to protect the public health and safety during a radiological emergency involving the Quad Cities Generating Station. The purpose of this exercise report is to present the exercise results and findings on the performance of the offsite response organizations (ORO) during a simulated radiological emergency.
The findings presented in this report are based on the evaluations of the Federal evaluator team, with final determinations made by the DHS/FEMA Region V RAC Chairperson, and approved by the Regional Director.
The criteria utilized in the DHS/FEMA evaluation process are contained in:
NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980; FEMA-REP-14, "Radiological Emergency Preparedness Exercise Manual,"
September 1991; and The FEMA "Radiological Emergency Preparedness: Exercise Evaluation Methodology; Notice," as published in the Federal Register Notice, Volume 67, Number 80, dated April 25, 2002.
Section III of this report, entitled "Exercise Overview," presents basic information and data relevant to the exercise. This section of the report contains a description of the plume pathway EPZ, a listing of all participating jurisdictions and functional entities which were evaluated, and a tabular presentation of the time of actual occurrence of key exercise events and activities.
Section IV of this report, entitled "Exercise Evaluation and Results," presents detailed information on the demonstration of applicable exercise criteria at each jurisdiction or functional entity evaluated in a jurisdiction-based, issues only format.
3
III.
EXERCISE OVERVIEW Contained in this section are data and basic information relevant to the July 21, 2004 exercise to test the offsite emergency response capabilities in the area surrounding the Quad Cities Generating Station. This section of the exercise report includes a description of the 10-mile plume pathway EPZ, a listing of all participating jurisdictions and functional entities which were evaluated, and a tabular presentation of the time of actual occurrence of key exercise events and activities.
A.
Plume Emergency Planning Zone Description The Quad Cities Generating Station is located in Rock Island County, Illinois.
The Station is 20 miles northeast of the Quad Cities. It is on the eastern bank of the Mississippi River opposite the mouth of the Wapsipinicon River.
The topography of the site and its immediate environs is low and relatively flat, with a mean elevation of approximately 605 feet. The ground surface drops off abruptly at the bank of the river, forming a bluff about 30 feet high.
The 10-mile EPZ encompasses the following jurisdictions: Rock Island County, which includes the municipalities of Cordova and Port Byron, and Whiteside County, which includes the municipality of Albany. The 2000 population of the 10-mile EPZ is 5,940 persons.
The primary land use around the Quad Cities Generating Station is agricultural, with cash grain crops of corn and soybeans. The closest major industries are located in the Cordova Industrial Park northeast of the Station.
Major transportation facilities in the Quad Cities Generating Station 10-mile EPZ are limited to Interstate Highway 88, which passes nine and one-half (9 /2) miles southeast of the Station; the Chicago, Milwaukee, St. Paul and Pacific Railroad, and State Highway 84 which run adjacent and parallel to each other and pass approximately three-fourths (3/4) of a mile east of the Station; and the Mississippi River.
B.
Exercise Participants The following agencies, organizations, and units of government participated in the Quad Cities Generating Station exercise on July 21, 2004.
STATE OF ILLINOIS Illinois Department of Natural Resources (IDNR)
Illinois Department of Transportation (IDOT)
Illinois Emergency Management Agency (IEMA)
RISK JURISDICTIONS ROCK ISLAND COUNTY Rock Island County Executive (Board Chair)
Rock Island County Emergency Services and Disaster Agency (ESDA)
Rock Island County Health Department Rock Island County Public Works Department Rock Island County Regional Office of Education Rock Island County Sheriff's Department WHITESIDE COUNTY Whiteside County Board Chairman Whiteside County ESDA Whiteside County Sheriffs Department Whiteside County Highway Department Whiteside County Health Department Whiteside County Coroner Whiteside County Public Information Officer Whiteside County Regional Office of Education Erie Fire Department Morrison Fire Department Morrison Police Department Riverbend School District #2 PRIVATE/VOLUNTEER ORGANIZATIONS American Red Cross Exelon Nuclear Radio Station WKBF/WHTS AM/FM Radio Station WSDR/WZZT/WSSQ AM/FM Radio Amateur Civil Emergency Service C.
Exercise Timeline Table 1, on the following page, presents the time at which key events and activities occurred during the Quad Cities Generating Station plume pathway exposure exercise on July 21, 2004. Also included are times that notifications were made to the participating jurisdictions/functional entities.
5
I -
1----
[77- [17
[77 r
F77T CO "
EAS'-' a,'-s bel'"
"ll'I INI'.
1--*-
F77 177 17 r
0o DATE AND SITE: July 21, 2004, Quad Cities Generating Station Time That Notilication Was Received or Action Was Taken l
Classircation iEOF STATE OF STATE FWD ROCK ISLAND W ITESIDE 1
Clasrcato Utcility Li OF REC ILLIN OIS C MD POST C O UNTY C OUNTY HI Unusual Event N/A N/A N/A N/A N/A N/A N/A N/A Alert 0810 0824 0827 0827 0847 0850 0849 N/A Sie Area Emergency 0945 1015 0954 0955 1015 1018 1017 0947 General Emergency 1101 1109 1109 1119 1126 1135 1135 1107 IM Release of Radioactive 1200 1220 1201 1214 1233 1234 1234 1207 Materials I
I IM Release Terminated N/A N/A N/A N/A N/A N/A N/A N/A lFacility Declared Operational ll 0909 0847 0855 0915 0925 0924 0945 Declaration of State of Disaster 111130 1130 1130 1130 1135 1130 1145 Exercise Terminated 11 1315 1315 1317 1317 1325 1322 1315 I' Early Precautionary Action Decision:
Place livestock on stored feed and protected 1015 1000 1015 1009 1019 1019 1009 water out to a 10-mile radius of the QCGS 11 ll
_____l____
2ndEarly Precautionary Action Decision:
N/A N/A N/A 1030 N/A N/A N/A Closure of W aterways N_______1030 ll lllll Instructional Message to the Public N/A N/A N/A N/A 1033 1033 1040 V Siren Activation:
N/A N/A N/A N/A 1040 1040 1040 I'l EBS Message:
N/A N/A N/A l
N/A 1042 1043 1040 3 Early Precautionary Action Decision:
Termination of Extra-Curricular School N/A N/A N/A N/A N/A 1035 N/A A ctivities 11 11_1
_1_1_.___1 I5 ProtectiveActionDecision:
1113 11 11 1126 1126 1137 I137 1121 Evacuate sub-areas I & 2 1113 1 _
1126 1126l1137 1137 1121 2hf Siren Activation:
N/A N/A N/A N/A 1143 1143 1143 2 EBS Message:
N/A N/A N/A N/A 1146 1146 1143 2"~Prtetie Action Decision:
Evacuatesubareasci
, 2,D3,4i&
5 1217 1214 1233 1233 1239 1239 1240 3fd Siren Activation:
N/A N/A N/A.
N/A 1247 1247 1247 3r'EBS Message:
N/A N/A N/A l
N/A 1252 1252 1247 KI Recommendation by State:
Emergency Workers & Immobilized 1119 1116 1126 1126 1134 1132 1118 Populations K! Decision by County:
Emergency Workers & Immobilized N/A N/A N/A N/A 1150 1157 N/A Populations ll
IV.
EXERCISE EVALUATION AND RESULTS Contained in this section are the results and findings of the evaluation of all jurisdictions and functional entities which participated in the July 21, 2004, exercise to test the offsite emergency response capabilities of State and local governments in the 10-mile EPZ surrounding the Quad Cities Generating Station.
Each jurisdiction and functional entity was evaluated on the basis of its demonstration of exercise criteria delineated in Federal Register Notice, Volume 67, Number 80, dated April 25, 2002. Detailed information on the exercise criteria and the extent-of-play agreement used in this exercise are found in Appendix 3 of this report.
A.
Summary Results of Exercise Evaluation - Table 2 The matrix presented in Table 2, on the following page(s), presents the status of all exercise criteria from Federal Register Notice, Volume 67, Number 80, dated April 25, 2002, that were scheduled for demonstration during this exercise by all participating jurisdictions and functional entities. Exercise criteria are listed by number and the demonstration status of those criteria is indicated by the use of the following letters:
M Met (No Deficiency or ARCAs assessed and no unresolved ARCAs from prior exercises)
D Deficiency assessed A
ARCA(s) assessed or unresolved ARCA(s) from prior exercise(s)
N Not demonstrated (Reason explained in Subsection B)
Blank -
Not scheduled for demonstration.
7
I V
F-
[-
r F -
F---
L- -
177-
[
[77 F-
[77 F
- 2.
SUMMARY
RESULTS OF EXE RCISE EVALUATION W- -
[-7 7
1 7 7 7
[
DATE AND SITE: July 21, 2002, Quid Cities Generating Station 00 2.2.2.2.
- 2. 2. 3
.3
.3
.3
- 3.
- 4. 4.
4.' 4, 4,~* 5. 5.
.S 6.1 6.1 6.16.
JLJRISDICTIONSIF UNCTIONAL, ENTITY 1 1 hf.e 1.d
.e
.I.eIa aI.bIa hIj STATE OF I LLINOIS Initial Warning Point M
Al State Emergency Operations Center M
M M Nl M Al M hi Radiological Emergency Assessment Center M
M Ni M NI Ni M Nl Ml hi State Forward Command Post hi M NI M M M Nl Ni Ni Ni Traffic and Access Control Point IM M ml ml Emergency Operations Facility M
Mml Joint Public Information Center Ml M MM N
Monitoring and Decontamination of Evacuees and Emergency Workers, M
M Al Ni and Regiotntlin a nVyaneeq I
I Monitoring and Decontamination of Emergency Worker Equipment M
Al Al M
Temporary Care of Evacuees M.M Ni N
IEMA Liaison in Rock Island County EOC M
M hi Ml IEMA Liaison in Whiteside County EOC M
M NiN RISK JURISDICTIONS ROCK ISLAND COUNTY Initial Notification Point M
M County Emergency Operations Center Ni M M Ni Ni Ml Ni M NI M Ai Ni N
Al Local Media Briefing M
INII I
Traffic and Access Control Point Mhi M M IMI I
EBS Radio Station WKBFAVIITS ANM/FM NiM N
l i
WIUTESIDE COUNTY Initial Notification Point Ml M
County Emergency Operations Center Ni AiA M IM M NiMIM A
M Ai l N NiA NINi Local Miedia Briefing NI N
I I
Traffic and Access Control Point hi i
MAl MA EBS Radio Station WSDRIWZZTIWSSQ AM/FM M
Nl NI Riverbend Community Unit School District #2 MI LEGEND:
Ml
= Met (No Deficiency or ARCA(s) assessed)
D = Deficiency assessed A = ARCA(s) assessed (Not affecting health and safety of pu~blic)
U = Unresolved ARCA(s) from prior exercises Bltank = Not scheduled for demonstration N = Not demonstrated as scheduled (Reason explained in Section WV.B.)
B.
Status of Jurisdictions Evaluated This subsection provides information on the evaluation of each participating jurisdiction and functional entity, in a jurisdiction based, issues only format.
Presented below is a definition of the terms used in this subsection relative to criterion demonstration status.
Met -Listing of the demonstrated exercise criteria under which no Deficiencies or ARCAs were assessed during this exercise and under which no ARCAs assessed during prior exercises remain unresolved.
Deficiency - Listing of the demonstrated exercise criteria under which one or more Deficiencies were assessed during this exercise. Included is a description of each Deficiency and recommended corrective actions.
Area Requiring Corrective Actions - Listing of the demonstrated exercise criteria under which one or more ARCAs were assessed during the current exercise or ARCAs assessed during prior exercises remain unresolved.
Included is a description of the ARCAs assessed during this exercise and the recommended corrective action to be demonstrated before or during the next biennial exercise.
Not Demonstrated - Listing of the exercise criteria which were not demonstrated as scheduled during this exercise and the reason(s) they were not demonstrated.
Prior ARCAs - Resolved - Descriptions of ARCAs assessed during previous exercises which were resolved in this exercise and the corrective actions demonstrated.
Prior ARCAs - Unresolved - Descriptions of ARCAs assessed during prior exercises which were not resolved in this exercise. Included is the reason the ARCA remains unresolved and recommended corrective actions to be demonstrated before or during the next biennial exercise.
The following are definitions of the two types of exercise issues which are discussed in this report.
A Deficiency is defined in FEMA-REP-14 as "...an observed or identified inadequacy of organizational performance in an exercise that could cause a finding that offsite emergency preparedness is not adequate to provide reasonable assurance that appropriate protective measures can be taken in the event of a radiological emergency to protect the health and safety of the public living in the vicinity of a nuclear power plant."
9
An ARCA is defined in FEMA-REP-14 as '"...an observed or identified inadequacy of organizational performance in an exercise that is not considered, by itself, to adversely impact public health and safety."
DHS/FEMA has developed a standardized system for numbering exercise issues (Deficiencies and ARCAs). This system is used to achieve consistency in numbering exercise issues among DHS/FEMA Regions and site-specific exercise reports within each Region. It is also used to expedite tracking of exercise issues on a nationwide basis.
The identifying number for Deficiencies and ARCAs includes the following elements, with each element separated by a hyphen (-).
Plant Site Identifier - A two-digit number corresponding to the Utility Billable Plant Site Code.
Exercise Year - The last two digits of the year the exercise was conducted.
Criterion Number - An alpha and two-digit numeric identifier corresponding to the criteria numbers in the six exercise evaluation areas described in FEMA "Radiological Emergency Preparedness: Exercise Evaluation Methodology; Notice," as published in the Federal Register Notice, Volume 67, Number 80, dated April 25, 2002, which amends FEMA-REP-14, Radiological Emergency Preparedness Exercise Manual.
Issue Classification Identifier - (D = Deficiency, A = ARCA). Only Deficiencies and ARCAs are included in exercise reports. Planning issues are reported to the State(s) via a letter from the Regional Director. Therefore, standardized issue numbers are not assigned to planning issues.
Exercise Issue Identification Number - A separate two (or three) digit indexing number assigned to each issue identified in the exercise.
10
L
- 1.
STATE OF ILLINOIS 1.1 Initial Warning Point
- a.
MET: Criteria 1.a.1 and 1.d.1
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 1.2 State Emergency Operations Center
- a.
MET: Criteria 1.a.1, 1.c.1, 1.d.1, L.e.1, 2.b.1, 2.b.2, 2.c.1 and 5.b.1
- b.
DEFICIENCY: NONE L
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 1.3 Radiological Emergency Assessment Center
- a.
MET: Criteria 1.a.1, 1.c.1, l.d.1, I.e.1, 2.a.1, 2.b.1, 2.b.2, 5.b.1, 6.a.1 and 6.b.1
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 11
L 1.4 State Forward Command Post
- a.
MET: Criteria 1.a.1, 1.c.1, 1.d.1, 1.e.l, 3.d.1, 3.d.2,5.b.1, 6.a.1, 6.b.1 and 6.c.1
- b.
DEFICIENCY: NONE L
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE L
1.5 Traffic and Access Control Point L
- a.
MET: Criteria 1.d.1, 3.a.1, 3.b.I and 3.d.1
- b.
DEFICIENCY: NONE L
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE I
- d.
NOT DEMONSTRATED: NONE L
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE L
1.6 Emergency Operations Facility
- a.
MET: Criteria 1.a.1, l.c.1 and 1.d.1
- b.
DEFICIENCY: NONE C.
AREAS REQUIRING CORRECTIVE ACTION: NONE L
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE L
1.7 Joint Public Information Center
- a.
MET: Criteria l.a.1, 1.c.1, 1.d.l, 1.e.1 and 5.b.1 12
L
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 1.8 Monitoring and Decontamination of Evacuees and Emergency Workers, and Registration of Evacuees I
- a.
MET: Criteria l.a.l, l.e.1, 3.a.1 and 6.a.1
- b.
DEFICIENCY: NONE
_t
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE L
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE L
- f.
PRIOR ARCAs -UNRESOLVED: NONE L
1.9 Monitoring and Decontamination of Emergency Worker Equipment
- a.
MET: Criteria l.a.1, l.e.l, 3.a.1 and 6.b.1
- b.
DEFICIENCY: NONE L
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE K
- f.
PRIOR ARCAs - UNRESOLVED: NONE 1.10 Temporary Care of Evacuees
- a.
MET: Criteria l.a.1, l.b.1, l.d.1 and 6.c.1
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE 13
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 1.11 IEMA Liaison in Rock Island County EOC
- a.
MET: 1.c.1, 2.b.1, 2.b.2 and 5.b.1,
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 1.12 IEMA Liaison in Whiteside County EOC L
- a.
MET: 1.c.1, 2.b.1, 2.b.2 and 5.b.1
- b.
DEFICIENCY: NONE L
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE L
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE
- 2.
RISK JURISDICTIONS L
2.1 ROCK ISLAND COUNTY 2.1.1 Initial Notification Point
- a.
MET: Criteria l.a.1 and l.d.l
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE 14
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE L
2.1.2 County Emergency Operations Center
- a.
MET: Criteria 1.a.1, 1.c.1, 1.d.1, 1.e.1, 2.b.2, 2.c.1, 3.a.1, 3.b.1, 3.c.1, 3.c.2, 3.d.1, 3.d.2, 5.a.1 and 5.b.1.
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE I
- f.
PRIOR ARCAs - UNRESOLVED: NONE 2.1.3 Local Media Briefing
- a.
MET: Criterion 1.e.1 and 5.b.1 L
- b.
DEFICIENCY: NONE L
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE L
- e.
PRIOR ARCAs - RESOLVED: NONE L
- f.
PRIOR ARCAs - UNRESOLVED: NONE L
2.1.4 Traffic and Access Control Point
- a.
MET: Criteria 1.d.1, l.e.1, 3.a.1, 3.b.1 and 3.d.1
- b.
DEFICIENCY: NONE C.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE 15
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 2.1.5 EBS Radio Station WKBFIWVHTS AM/FI
- a.
MET: Criteria 1.d.1, 5.a.1 and 5.b.1
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 2.2 WHI-TESIDE COUNTY 2.2.1 Initial Notification Point
- a.
MET: Criteria 1.a.1 and 1.d.1
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 2.2.2 County Emergency Operations Center
- a.
MET: Criteria 1.a.l, 1.c.1, 1.d.1, I.e.1, 2.b.2, 2.c.1, 3.a.1, 3.b.1, 3.c.1, 3.c.2, 3.d.1, 3.d.2, 5.a.1 and 5.b.1
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE 16
L
- f.
PRIOR ARCAs - UNRESOLVED: NONE 2.2.3 Local Media Briefing
- a.
MET: Criterion L.e.1 and 5.b.1
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 2.2.4 Traffic and Access Control Point
- a.
MET: Criteria 1.d.1, I.e.1, 3.a.1, 3.b.1 and 3.d.1 L
- b.
DEFICIENCY: NONE L
- c. AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE L
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 2.2.5 EBS Radio Station WSDRJWZZT/WSSQ AM/FM
- a.
MET: Criteria L.a.l, 5.a.1 and 5.b.1 L
- b.
DEFICIENCY: NONE C.
AREAS REQUIRING CORRECTIVE ACTION: NONE d;
NOT DEMONSTRATED: NONE L
- e.
PRIOR ARCAs - RESOLVED: NONE l
- f.
PRIOR ARCAs - UNRESOLVED: NONE 17
2.2.6 Riverbend Community Unit School District #2
- a.
MIET: Criterion 3.c.2
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAS - UNRESOLVED: NONE 18
APPENDIX 1 ACRONYINIS AND ABBREVIATIONS The following is a list of the acronyms and abbreviations which were used in this report.
ACP ARC ARCA Access Control Point American Red Cross Area Requiring Corrective Action CAP CDV L
CFR CPM L
EOF EPZ ESDA Civil Air Patrol Civil Defense - Category V Code of Federal Regulations Counts Per Minute U.S. Department of Energy Direct Reading Dosimeter Emergency Action Level Emergency Alert System Emergency Broadcast System Emergency Classification Level Emergency Operations Center Emergency Operations Facility Emergency Planning Zone Emergency Services and Disaster Agency GE General Emergency ICC IDA M
IHS L
IDMA IDNR l
IDNS IDOT-A IDOT-H MIDPH IEMA IIEPA i,
IPRA IREACH Is ISP Illinois Commerce Commission Illinois Department of Agriculture Illinois Department of Human Services Illinois Department of Military Affairs Illinois Department of Natural Resources Illinois Department of Nuclear Safety Illinois Department of Transportation - Division of Aeronautics Illinois Department of Transportation - Division of Highways Illinois Department of Public Health Illinois Emergency Management Agency Illinois Environmental Protection Agency Illinois Plan for Radiological Accidents Illinois Radio Emergency Aid Channel Illinois State Police 19
JIC JPIC KI Joint Information Center Joint Public Information Center Potassium Iodide milliroentgen milliroentgen per hour.
mR mR/h NARS I
NRC L
ORO I
IPAD L
PAG PAO I
PAR L~
PIO PNS Nuclear Accident Reporting System U.S. Nuclear Regulatory Commission NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, " November 1980 National Weather Service Offsite Response Organization Protective Action Decision Protective Action Guide Public Affairs Official Protective Action Recommendation Public Information Officer Prompt Notification System L
R RAC i
RACES RAFT RDO X
REA REAC REM I
SEOC L
TCP TL I
TLD Roentgen Regional Assistance Committee Radio Amateur Civil Emergency Service Radiological Assessment Field Team Radiological Defense Officer Radioactive Emergency Area Radiological Emergency Assessment Center Roentgen Equivalent Man Radiological Emergency Preparedness Roentgen(s) per hour Radiological Officer Site Area Emergency State Emergency Operations Center State Forward Command Post Standard Operating Procedure Traffic Control Point Team Leader Thermoluminescent Dosimeter 20
APPENDIX 2 EXERCISE EVALUATORS AND TEAM LEADERS The following is a list of the personnel who evaluated the Quad Cities Generating Station exercise on July 21, 2004. Evaluator Team Leaders are indicated by the letters "(TL)" after their names. The organization which each evaluator represents is indicated by the following abbreviations:
DHS/FEMA
- Department of Homeland Security/Federal Emergency Management Agency L
ICF
- ICF Consulting RAC CHAIR/EXERCISE DIRECTOR NAME ORGANIZATION RAC Chair Exercise Director W. King G. Naskrent DHS/FEMA DHS/FEMA ORGANIZATION EVALUATION SITE EVALUATOR STATE OF ILLINOIS Emergency Operations Center Radiological Emergency Assessment Center State Forward Command Post -
Traffic and Access Control Emergency Operations Facility Joint Public Information Center Monitoring and Decontamination of Evacuees and Emergency Workers, and Registration of Evacuees Monitoring and Decontamination of Emergency Worker Equipment Temporary Care of Evacuees C. Sturghill (TL)
D. Kinsley R. Grundstrom J. Fox T. Connors-Hartman L. Visniesky J. Staroba P. Tenorio J.Fox DHS/FEMA DHS/FEMA ICF ICF DHS/FEMA ICF ICF DHS/FEMA ICF J. Fox ICF J. Staroba ICF ROCK ISLAND COUNTY Emergency Operations Center Traffic and Access Control EBS Radio Station WKBF/WHTS C. Crackel (TL)
R. Argall W. Gawlak R. Marks R. Marks R. Argall DHS/FEMA ICF ICF ICF ICF ICF 21
EVALUATION SITE EVALUATOR ORGANIZATION WHITESIDE COUNTY Emergency Operations Center Traffic and Access Control EBS Radio Station WSDR/WZZT/WSSQ Riverbend Community Unit School District C. Bebrich (TL)
S. Bailey R. Black W. Edmonson W. Edmonson S. Lowery C. Crackel DHS/FEMA DHS/FEMA ICF ICF ICF ICF DHS/FEMA 22
APPENDIX 3 EXERCISE CRITERIA AND EXTENT-OF-PLAY AGREEMENT This appendix lists the exercise criteria that were scheduled for demonstration in the Quad Cities Generating Station exercise on July 21, 2004, and the extent-of-play agreement.
The exercise criteria, contained in the FEMA "Radiological Emergency Preparedness Exercise L
Evaluation Methodology; Notice," as published in the Federal Register Notice dated April 25, 2002, represent a functional translation of the planning standards and evaluation criteria of L
NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for the Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants,"
November 1980.
Because the exercise objectives are intended for use at all nuclear power plant sites, and because of variations among offsite plans and procedures, an extent-of-play agreement is prepared by the State and approved by DHS/FEMA to provide evaluators with guidance on expected actual demonstration of the criteria.
A.
Exercise Criteria Listed below are the specific radiological emergency preparedness criteria scheduled for L
demonstration during this exercise.
EVALUATION AREA 1: EMERGENCY OPERATIONS MANAGEMENT CRITERION 1.a.1: OROs use effective procedures to alert, notify and mobilize emergency personnel and facilities in a timely manner.
CRITERION 1.b.1: Facilities are sufficient to support the emergency response.
CRITERION 1.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.
CRITERION 1.d.1: At least two communications systems are available, at least one L
operates properly, and communication links are established and maintained with appropriate locations. Communications capabilities are managed in support of emergency operations.
CRITERION 1.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI),
and other supplies are sufficient to support emergency operations.
EVALUATION AREA 2: PROTECTIVE ACTION DECISION-MAKING 23
CRITERION 2.a.1: OROs use a decision-making process, considering relevant factors and appropriate coordination, to ensure that an exposure control system, including the use of KI, is in place for emergency workers including provisions to authorize radiation exposure in excess of administrative limits or protective action guides.
CRITERION 2.b.1: Appropriate protective action recommendations are based on available information on plant conditions, field monitoring data, and licensee and ORO dose projections, as well as knowledge of on-site and off-site environmental conditions.
CRITERION 2.b.2: A decision-mak-ing process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PADs) for the general public (including the recommendation for the use of KI, if ORO policy).
CRITERION 2.c.1: Protective action decisions are made, as appropriate, for special population groups.
EVALUATION AREA 3: PROTECTIVE ACTION IMPLEMENTATION CRITERION 3.a.1: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plans and procedures. Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart.
CRITERION 3.b.1: KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals (not the general public) is maintained.
CRITERION 3.c.1: Protective action decisions are implemented for special populations other than schools within areas subject to protective actions.
CRITERION 3.c.2: OROs/School officials decide upon and implement protective actions for schools.
CRITERION 3.d.1: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel.
CRITERION 3.d.2: Impediments to evacuation are identified and resolved.
EVALUATION AREA 5: EMERGENCY NOTIFICATION & PUBLIC INFORMATION 24
CRITERION 5.a.1: Activities associated with primary alerting and notification of the public are completed in as timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation.
The initial instructional message to the public must include as a minimum the elements required by current FEEMA REP guidance.
CRITERION 5.b.1: OROs provide accurate emergency information and instructions to the public and the news media in a timely manner.
EVALUATION AREA 6: SUPPORT OPERATION/FACILITIES CRITERION 6.a.1: The reception center/emergency worker facility has appropriate space, adequate resources, and trained personnel to provide monitoring, decontamination, and registration of evacuees and/or emergency workers.
CRITERION 6.b.1: The facility/ORO has adequate procedures and resources for the accomplishment of monitoring and decontamination of emergency worker equipment including vehicles.
CRITERION 6.c.1: Managers of congregate care facilities demonstrate that the centers have resources to provide services and accommodations consistent with American Red Cross planning guidelines (found in MASS CARE-Preparedness Operations, ARC 3031). Managers demonstrate the procedures to assure that evacuees have been monitored for contamination and have been decontaminated as appropriate prior to entering congregate care facilities.
B.
Extent-of-Play Agreement The extent-of-play agreement on the following pages was submitted by the State of Illinois in preparation for the Quad Cities Generating Station exercise on July 21, 2004.
The extent-of-play agreement includes any significant modification or change in the level of demonstration of each exercise criterion listed in Subsection A of this appendix.
STATE OF ILLINOIS CRITERIA:
Criteria that can be re-demonstrated immediately for credit, at the discretion of the evaluator, include the following: 3.a.1, 3.d.1, 3.d.2, 6.a.1, 6.b.1, 6.c.1 and 6.d.1. Criteria that may be re-demonstrated, as approved on a case-by-case basis by the Chairperson of the Regional Assistance Committee, include the following: 2.a.1, 2.b.1, 2.b.2, 5.a.1 and 5.b.1.
EVALUATION AREA 1 - EMERGENCY OPERATIONS MANAGEMENT Criterion 1.a.1: OROs use effective procedures to alert, notify and mobilize emergency personnel and activate facilities in a timely manner.
25
The State Emergency Operations Center (EOC) will be partially activated. The IEMA Emergency Response Teleconmmunicator will implement procedures for notification of IEMA staff as defined in IEMA SOPs. IEMA representatives will staff the State EOC.
REAC will be fully activated. Rosters will be provided to demonstrate 24-hour staffing of the State EOC and REAC.
The State Forward Command Post (SFCP) at the IDOT Maintenance Facility near Lyndon will be activated with State district and regional personnel. RAFT will be activated for training purposes. IEMA personnel will be pre-positioned in the local area and dispatched to the county EOCs, SFCP, EOF and the JPIC.
The pre-positioned State staff will begin exercise play no earlier than the Alert.
Criterion 1.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.
The ability to direct and control emergency response activities will be demonstrated at the State EOC, REAC, the SFCP and the JPIC. Coordination will be demonstrated between the State EOC, REAC, the SFCP, the JPIC, the EOF and the county EOCs.
Criterion 1.d.1: At least two communication systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations. Communications capabilities are managed in support of emergency operations.
IEMA will use a variety of communication systems [Nuclear Accident Reporting System (NARS), telefax, commercial telephone, radio] to communicate with other organizations and locations.
Criterion 1.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI) and other supplies are sufficient to support emergency operations.
The State of Illinois will demonstrate the use of equipment, maps and displays to support emergency operations. The use of dosimetry/KI will be demonstrated at the SFCP in conjunction with the traffic and access control demonstration. DCO logs will be available from the IEMA Radiological Advisors in the county EOCs.
EVALUATION AREA 2 - PROTECTIVE ACTION DECISION MAKING Criterion 2.a.1: OROs use a decision-making process, considering relevant factors and appropriate coordination, to ensure that an exposure control system, including the use of KI, is in place for emergency workers including provisions to authorize radiation exposure in excess of administrative limits or protective action guides.
26
The ability to make the decision to recommend the use of KI to emergency workers will be demonstrated in REAC. A message will be injected to drive the decision to authorize exposure in excess of administrative limits.
Criterion 2.b.1: Appropriate protective action recommendations are based on available information on plant conditions, field monitoring data and licensee and ORO dose projections, as well as knowledge of on-site and off-site environmental conditions.
REAC will evaluate the licensee information and complete independent dose projections based on that information and simulated field monitoring data. REAC will make an evaluation of the data and make a protective action recommendation to the State EOC.
Criterion 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PADs) for the general public (including the recommendation for the use of KI, if ORO policy).
The coordination to determine protective action recommendations (PARs) based upon available shelters, evacuation time estimates and other relevant factors will be demonstrated between the State EOC and REAC.
Criterion 2.c.1: Protective action decisions are made, as appropriate, for special population groups.
The coordination to determine protective action recommendations (PARs) based upon available shelters, evacuation time estimates and other relevant factors will be demonstrated between the State EOC and REAC.
The ability to make the decision to recommend the use of KI to institutionalized persons will be demonstrated in REAC.
EVALUATION AREA 3 - PROTECTIVE ACTION IMPLEMENTATION Criterion 3.a.1: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plan and procedures.
Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart.
This will be demonstrated during the traffic and access control demonstration at the SFCP. The Illinois State Police will bring dosimetry packets to the SFCP from their district headquarters.
Criterion 3.b.1: KI and appropriate instructions area available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals (not the general public) is maintained.
27
This will be demonstrated during the traffic and access control demonstration. The Illinois State Police will bring dosimetry packets to the SFCP from their district headquarters.
Criterion 3.d.1: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel.
This will be demonstrated by the State through coordination between the SFCP and the county EOCs, in accordance with the Quad Cities Station EPZ Traffic and Access Control Procedures. The Illinois State Police (ISP) will demonstrate one traffic and access control post during the exercise. The post for the demonstration will be selected by the ISP during the exercise based on exercise play. The trooper will drive to the selected post location for the demonstration. The staffing of the remaining State posts will be simulated.
Criterion 3.d.2: Impediments to evacuation are identified and resolved.
This will be demonstrated through discussions at the SFCP between the Illinois State Police and Illinois Department of Transportation. A message will be injected by a Controller that will drive this demonstration. State personnel will deal with the impediment by discussing the need for equipment, discussing its estimated time of arrival, etc. Actual contacts with resource providers will be made and logged.
EVALUATION AREA 5 - EMERGENCY NOTIFICATION AND PUBLIC INFORMATION Criterion 5.a.1: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current FEMA REP guidance.
The State's role in demonstrating this criterion is limited to transmitting the State's protective action recommendation (PAR) to the counties and monitoring the instructional messages provided to the public by the counties. This monitoring will be accomplished by the SFCP through the IEMA representatives in the county EOCs.
Criterion 5.b.1: OROs provide accurate emergency information and instructions to the public and the news media in a timely manner.
This will be demonstrated at the JPIC -in coordination with the State EOC, REAC, SFCP and the county EOCs. IEMA personnel will be present at the JPIC to coordinate with the utility staff. Media briefings will be conducted at the JPIC. A livestock advisory will be issued to the media from the JPIC or the State EOC when appropriate.
28
A rumor control phone bank for public inquiries will not be operated by the State during the exercise.
EVALUATION AREA 6 - SUPPORT OPERATION/FACILITIES Criterion 6.a.1: The reception center/emergency worker facility has appropriate space, adequate resources, and trained personnel to provide monitoring, decontamination, and registration of evacuees and/or emergency workers.
During the exercise, the capability to determine which centers should be activated for monitoring, decontamination and registration will be demonstrated through coordination between the SFCP and REAC.
An interview of State and local officials and inspection of Morrison High School will be conducted on July 20 at 11:00 a.m. The following organizations will be represented at the interview: Whiteside County ESDA and Health Department, Morrison Police and Fire Departments, American Red Cross and IEMA. Evacuees will not be processed.
Monitoring equipment will not be available at the interview/inspection.
Criterion 6.b.1: The facility/ORO has adequate procedures and resources for the accomplishment of monitoring and decontamination of emergency worker equipment including vehicles.
During the exercise, the capability to determine which facilities will be used for monitoring and decontamination of emergency workers, equipment and vehicles will be demonstrated through coordination between the SFCP and REAC.
An interview of State and local officials and inspection of Morrison High School will be conducted on July 20 at 11:00 a.m. The following organizations will be represented at the interview: Whiteside County ESDA and Health Department, Morrison Police and Fire Departments, American Red Cross and IEMA. Emergency workers and equipment will not be processed. Monitoring equipment will not be available at the interview/inspection.
Criterion 6.c1: Managers of congregate care facilities demonstrate that the centers have resources to provide services and accommodations consistent with American Red Cross planning guidelines. Managers demonstrate the procedures to assure that evacuees have been monitored for contamination and have been decontaminated as appropriate prior to entering congregate care facilities.
During the exercise, the capability to determine which congregate care centers should be activated will be demonstrated at the SFCP.
An interview of local officials and inspection of Morrison High School will be conducted on July 20 at 11:00 a.m. Representatives of the American Red Cross will be present for 29
the interview. Evacuees will not be processed. Equipment will not be available at the interview/inspection.
ROCK ISLAND COUNTY CRITERIA:
Criteria that can be re-demonstrated immediately for credit, at the discretion of the evaluator, include the following: 3.a.1, 3.d.1, 3.d.2, 6.a.1, 6.b.1, 6.c.1 and 6.d.1. Criteria that may be re-demonstrated, as approved on a case-by-case basis by the Chairperson of the Regional Assistance Committee, include the following: 2.a.1, 2.b.1, 2.b.2, 5.a.1 and 5.b.l.
EVALUATION AREA 1 - EMERGENCY OPERATIONS MANAGEMENT Criterion 1.a.1: OROs use effective procedures to alert, notify and mobilize emergency personnel and activate facilities in a timely manner.
Rock Island County intends to fully activate the Emergency Operations Center (EOC) in Milan, Illinois. The County will implement notification procedures as defined in IPRA-Quad Cities. Representatives from IEMA, ISP and Exelon will staff the County EOC but will not be pre-positioned in the EOC. A roster will be provided to demonstrate 24-hour staffing of the EOC.
An evaluator will be positioned at the County Sheriff's Communications Center (initial warning point) at the start of the exercise.
Criterion 1.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.
Decision-making will be demonstrated at the State EOC and Rock Island County EOC.
Coordination of decisions and emergency activities will be demonstrated between Rock Island County, the State EOC, the SFCP, the JPIC, and between the County and municipalities within the EPZ. Coordination between Rock Island County and Whiteside County will be demonstrated.
Criterion 1.d.1: At least two communication systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations. Communications capabilities are managed in support of emergency operations.
Rock Island County will use NARS, commercial telephone, radio and telefax to communicate with departments and agencies at other locations.
Criterion 1.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI) and other supplies are sufficient to support emergency operations.
30
Rock Island County will adequately demonstrate the ability to support operations through the use of maps, status boards and other displays as appropriate. The use of dosimetry and KI will be demonstrated during the traffic and access control demonstration.
EVALUATION AREA 2 - PROTECTIVE ACTION DECISION MAKING Criterion 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PADs) for the general public (including the recommendation for the use of KI, if ORO policy).
The State of Illinois will make protective action recommendations to Rock Island County officials in the County EOC. The Rock Island County officials will make the final decision regarding what protective actions will be recommended to the public.
Criterion 2.c.1: Protective action decisions are made, as appropriate, for special population groups.
The State of Illinois will make protective action recommendations to Rock Island County officials in the County EOC. The Rock Island County officials will make the final decision regarding what protective actions will be recommended to the special population groups.
EVALUATION AREA 3 - PROTECTIVE ACTION IMPLEMENTATION Criterion 3.a.1: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plan and procedures.
Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart.
Rock Island County will demonstrate this criterion by close coordination with JEMA and timely dissemination and exchange of information within the County Dosimetry Control Officer network. Exercise messages will be injected which will ensure the opportunity to demonstrate this criterion in the County EOC.
This criterion will also be demonstrated during the traffic and access control demonstration.
Criterion 3.b.1: KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals (not the general public) is maintained.
When notified by the State of Illinois to distribute and administer KI, Rock Island County officials will discuss the issuance of KI to emergency workers and immobile populations, as a voluntary measure, and will notify the municipalities of the State's recommendation.
31
Criterion 3.c.1: Protective action decisions are implemented for special population groups within areas subject to protective actions.
This will be demonstrated by Rock Island County through the simulated implementation of the appropriate procedures. The appropriate officials will coordinate transportation and receiving facilities for special populations. One of each type of transportation provider (ambulance/bus) will be contacted during the exercise. The public will not be involved in the demonstration.
The Mobility Impaired List will be available for inspection in the County EOC during the exercise.
Criterion 3.c.2: OROs/School officials decide upon and implement protective actions for schools.
Rock Island County officials will demonstrate this capability through the simulated implementation of the appropriate procedures in the County EOC. The EPZ schools and transportation providers will be contacted during the exercise.
An interview with Riverdale School District staff was conducted in 2002. Therefore, a school interview will not be conducted in conjunction with this exercise.
Criterion 3.d.1: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel.
Coordination between Rock Island County agencies designated to provide traffic and access control will be exhibited in the County EOC. A Sheriffs deputy will be available during the exercise to demonstrate the staffing of one post. The post for the demonstration will be selected by Rock Island County during the exercise based on exercise play. The deputy will drive to the selected post location for the demonstration.
The staffing of the remaining posts will be simulated.
Criterion 3.d.2: Impediments to evacuation are identified and resolved.
The Rock Island County EOC staff will demonstrate the capability to identify and take appropriate actions concerning impediments to evacuation. A message will be injected by the Controller that will drive this demonstration. County personnel will deal with the impediment by identifying the equipment needed, discussing its estimated time of arrival, etc. Actual contacts with resource providers will be made and logged.
EVALUATION AREA 5 - EMERGENCY NOTIFICATION AND PUBLIC INFORMATION Criterion 5.a.1: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The initial 32
instructional message to the public must include as a minimum the elements required by current FEMA REP guidance.
Rock Island County will demonstrate the capability to provide both an alert signal and an initial instructional message to populated areas throughout the 10-mile plume pathway EPZ in a timely manner after their decision to activate the alert and notification system to implement protective action recommendations (PAR).
This capability will be demonstrated through the simulated activation of the Quad Cities Station EPZ Prompt Notification System as defined in IPRA-Quad Cities. The Prompt Notification System (outdoor warning sirens) will not be activated during the exercise.
The ability to provide instructions to the public will be demonstrated through the simulated activation of the local radio station. The local radio station (WKBF/WHTS) will be contacted for the first, and possibly the second, alert and notification sequence.
An evaluator and controller will be positioned at the radio station during the exercise to monitor the messages. If the initial message does not contain a protective action recommendation, the evaluator and controller will stay at the radio station for the second message. Rock Island County's Emergency Alert System (EAS) capability will be demonstrated with a test of the system after the exercise is terminated.
Coordination between Rock Island County and Whiteside County will be demonstrated.
Criterion 5.b.1: OROs provide accurate emergency information and instructions to the public and the news media in a timely manner.
Rock Island County will demonstrate this criterion by using pre-scripted messages as indicated in IPRA-Quad Cities. Contact with the radio station will be simulated for each alert and notification sequence following the sequence issuing the initial protective action recommendation.
The ability to provide information to the media will be demonstrated by Rock Island County through briefings held at the Rock Island County media briefing location. If real media are not present for the briefings, the controller and observers will serve as mock media. Evaluators will not serve as mock media; The ability to deal with rumors will be demonstrated by Rock Island County through coordination between the County EOC and the JPIC. The Rock Island County EOC controller will inject exercise messages which will ensure the opportunity to demonstrate this criterion. County officials will investigate and address "rumors." If appropriate, the "rumors" will be coordinated between State and County officials in the County EOC and the JPIC.
County emergency broadcast messages and news releases, if issued, will be faxed to the JPIC.
33
WHILTESIDE COUNTY CRITERIA:
Criteria that can be re-demonstrated immediately for credit, at the discretion of the evaluator, include the following: 3.a.1, 3.d.1, 3.d.2, 6.a.1, 6.b.1, 6.c.1 and 6.d.1. Criteria that may be re-demonstrated, as approved on a case-by-case basis by the Chairperson of the Regional Assistance Committee, include the following: 2.a.1, 2.b.1, 2.b.2, 5.a.1 and 5.b. 1.
EVALUATION AREA 1 -EMERGENCY OPERATIONS MANAGEMENT Criterion 1.a.1: OROs use effective procedures to alert, notify and mobilize emergency personnel and activate facilities in a timely manner.
Whiteside County intends to fully activate the Emergency Operations Center (EOC) in Morrison, Illinois. The County will implement notification procedures as defined in IPRA-Quad Cities. Representatives from IEMA, ISP and Exelon will staff the County EOC but will not be pre-positioned in the EOC. A roster will be provided to demonstrate 24-hour staffing of the EOC.
An evaluator will be positioned at the County Sheriff's Communications Center (initial warning point) at the start of the exercise.
Criterion 1.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible.
Decision-making will be demonstrated at the State EOC and Whiteside County EOC.
Coordination of decisions and emergency activities will be demonstrated between Whiteside County, the State EOC, the SFCP, the JPIC, and between the County and Albany. Coordination between Whiteside County and Rock Island County will be demonstrated.
Criterion 1.d.1: At least two communication systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations. Communications capabilities are managed in support of emergency operations.
Whiteside County will use NARS, commercial telephone, radio and telefax to communicate with departments and agencies at other locations.
Criterion 1.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI) and other supplies are sufficient to support emergency operations.
Whiteside County will adequately demonstrate the ability to support operations through the use of maps, status boards and other displays as appropriate. The use of dosimetry and KI will be demonstrated during the traffic and access control demonstration.
34
EVALUATION AREA 2 - PROTECTIVE ACTION DECISION MAKING Criterion 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PADs) for the general public (including the recommendation for the use of KI, if ORO policy).
The State of Illinois will make protective action recommendations to Whiteside County officials in the County EOC. The Whiteside County officials will make the final decision regarding what protective actions will be recommended to the public.
Criterion 2.c1: Protective action decisions are made, as appropriate, for special population groups.
The State of Illinois will make protective action recommendations to Whiteside County officials in the County EOC. The Whiteside County officials will make the final decision regarding what protective actions will be recommended to the special population groups.
EVALUATION AREA 3 - PROTECTIVE ACTION IMPLEMENTATION Criterion 3.a.1: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plan and procedures.
Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart.
Whiteside County will demonstrate this criterion by close coordination with IEMA and timely dissemination and exchange of information within the County Dosimetry Control Officer network. Exercise messages will be injected which will ensure the opportunity to demonstrate this criterion in the County EOC.
This criterion will also be demonstrated during the school interview and the traffic and access control demonstration.
Criterion 3.b.1: KI and appropriate instructions are available should a decision to recommend use of KI be made. Appropriate record keeping of the administration of KI for emergency workers and institutionalized individuals (not the general public) is maintained.
When notified by the State of Illinois to distribute and administer KI, Whiteside County officials will discuss the issuance of KI to emergency workers and immobile populations, as a voluntary measure, and will notify Albany officials of the State's recommendation.
Criterion 3.c1: Protective action decisions are implemented for special population groups within areas subject to protective actions.
This will be demonstrated by Whiteside County through the simulated implementation of the appropriate procedures. The appropriate officials will coordinate transportation and 35
receiving facilities for special populations. One of each type of special facility will be contacted during the exercise. One of each type of transportation provider (ambulance/bus) will be contacted during the exercise. The public will not be involved in the demonstration.
'Te Mobility Impaired List will be available for inspection in the County EOC during the exercise.
Criterion 3.c.2: OROs/School officials decide upon and implement protective actions for schools.
Whiteside County officials will demonstrate this capability through the simulated implementation of the appropriate procedures in the County EOC. The EPZ school and transportation provider will be contacted during the exercise.
A school interview will be conducted at Albany Elementary School in May 2004.
Criterion 3.d.1: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control personnel.
Coordination between Whiteside County agencies designated to provide traffic and access control will be exhibited in the County EOC. A Sheriff's deputy will be available during the exercise to demonstrate the staffing of one post. The post for the demonstration will be selected by Whiteside County during the exercise based on exercise play. The deputy will drive to the selected post location for the demonstration.
The staffing of the remaining posts will be simulated.
Criterion 3.d.2: Impediments to evacuation are identified and resolved.
The Whiteside County EOC staff will demonstrate the capability to identify and take appropriate actions concerning impediments to evacuation. A message will be injected by the Controller that will drive this demonstration. County personnel will deal with the impediment by identifying the equipment needed, discussing its estimated time of arrival, etc. Actual contacts with resource providers will be made and logged.
EVALUATION AREA 5 - EMERGENCY NOTIFICATION AND PUBLIC INFORMATION Criterion 5.a.1: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current FEMA REP guidance.
Whiteside County will demonstrate the capability to provide both an alert signal and an initial instructional message to populated areas throughout the 10-mile plume pathway 36
EPZ in a timely manner after their decision to activate the alert and notification system to implement protective action recommendations (PAR).
This capability will be demonstrated through the simulated activation of the Quad Cities Station EPZ Prompt Notification System as defined in IPRA-Quad Cities. The Prompt Notification System (outdoor warning sirens) will not be activated during the exercise.
The ability to provide instructions to the public will be demonstrated through the simulated activation of the local radio station. The local radio station (WSDR/WZZT/WSSQ) will be contacted during the first, and possibly the second, alert and notification sequence. An evaluator and controller will be positioned at the radio station during the exercise to monitor the messages. If the initial message does not contain a protective action recommendation, the evaluator and controller will stay at the radio station for the second message.
Coordination between Whiteside County and Rock Island County will be demonstrated.
Criterion 5.b.1: OROs provide accurate emergency information and instructions to the public and the news media in a timely manner.
Whiteside County will demonstrate this criterion by using pre-scripted messages as indicated in IPRA-Quad Cities. Contact with the radio station will be simulated for each alert and notification sequence following the initial protective action recommendation.
The ability to provide information to the media will be demonstrated by Whiteside County through briefings held at the Whiteside County media briefing location. If real media are not present for the briefings, the controller and observers will serve as mock media. Evaluators will not serve as mock media.
The ability to deal with rumors will be demonstrated by Whiteside County through coordination between the County EOC and the JPIC. The Whiteside County EOC controller will inject exercise messages that will ensure the opportunity to demonstrate this criterion. County officials will investigate and address "rumors." If appropriate, the "rumors" will be coordinated between State and County officials in the County EOC and the JPIC.
County emergency broadcast messages and news releases, if issued, will be faxed to the JPIC.
37
APPENDIX 4 EXERCISE SCENARIO This appendix contains a summary of the simulated sequence of events -- Exercise Scenario --
that was used as the basis for invoking emergency response actions by OROs in the Quad Cities Generating Station exercise on July 21, 2004.
This exercise scenario was submitted by the State of Illinois and Exelon and approved by DHS/FEMA Region V on July 16, 2004.
During the exercise, controllers from the State of Illinois gave "inject messages," containing scenario events and/or relevant data, to those persons or locations who would normally receive notification of such events. These inject messages were the method used for invoking response actions by OROs.
SCENARIO
SUMMARY
0745 Initial Conditions/Weather forecast message to players.
L 0800 An ALERT is declared at Quad Cities Station.
0815 Exelon notifies the IEMA Telecomnmunicator of the ALERT via NARS.
IEMA Telecommunicator verifies the NARS message.
An IEMA Duty Officer contacts the Quad Cities Station Shift Engineer.
I EMA Telecommunicator notifies IEMA personnel of the ALERT per SOP.
IEMA may activate the State EOC and REAC, if appropriate.
LEMA may dispatch liaisons to the county EOCs, Forward Command Post, RAFT, JPIC, TSC and EOF, if appropriate.
JIEMA notifies Governor's Office of the ALERT. (Simulated) lEMA Telecommunicator notifies appropriate State agencies of the ALERT.
IIEMA notifies FEMA of the ALERT. (Simulated)
L 0830 IEMA Telecomnmunicator notifies the counties of the ALERT via NARS.
County telecommunicators complete and verify the NARS message.
38
County telecommunicators notify county officials and municipalities of the ALERT per SOP.
Counties may activate the EOCs, if appropriate.
Municipal Telecommunicators complete and verify the NARS message.
L Municipal Telecommunicators notify officials of the ALERT per SOP.
L 0930 A SITE AREA EMERGENCY is declared at Quad Cities Station.
0945 Exelon notifies IEMA Telecommunicator of the SITE AREA EMERGENCY via L
NARS.
IEMA Telecommunicator verifies the NARS message.
REAC contacts the Quad Cities Station Shift Engineer.
State EOC is activated if not previously activated.
State EOC notifies the Governor's Office and requests that a representative report to the State EOC. (Simulated)
State dispatches liaisons to the county EOCs, Forward Command Post, RAFT, JPIC, TSC and EOF, if not previously dispatched.
State EOC notifies FEMA of conditions. (Simulated)
EEMA notifies State agencies (Simulated):
- Illinois State Police
- IDOT/Division of Highways
- IDOT/Aeronautics I.
- IDNR
- Illinois National Guard
- ICC
- American Red Cross
- JIDPH
- IEPA L
-IDOC
- Office of State Fire Marshal
- others as appropriate REAC contacts Federal agencies. (Simulated)
REAC provides in update to the State EOC and County EOC Liaisons.
39
REAC provides an update to the JPIC.
1000 IElVIA notifies the counties of the SITE AREA EMERGENCY via NARS.
County telecommunicators complete and verify the NARS message.
County telecommunicators notify County officials and municipalities of the SITE AREA EMERGENCY per SOP.
L County EOCs are activated if not previously activated.
L Counties implement public notification procedures, if appropriate. (Simulated)
Municipal Telecommunicators complete and verify the NARS message.
Municipal Telecommunicators notify officials per SOP.
Dosimetry is issued to emergency personnel, EOC staff and exposure records are L_
completed.
1100 A GENERAL EMERGENCY is declared at Quad Cities Station.
1115 Exelon notifies the IEMA Telecommunicator of the GENERAL EMERGENCY via NARS. Protective actions are recommended.
IEMA Telecommunicator verifies the NARS message.
The State EOC and REAC evaluate the protective action recommendation.
A recommendation is made to the Governor. The Governor recommends that protective actions be implemented.
State EOC staff is advised of the situation.
State EOC advises State Forward Command Post, the County EOC liaisons and JPIC staff of the situation.
State EOC notifies FEMA of conditions. (Simulated)
REAC provides an update to the State EOC Liaison and County EOC Liaisons.
REAC provides an update to the JPIC.
1130 State EOC notifies the counties of the GENERAL EMERGENCY and the recommended protective actions via NARS.
40
County telecommunicators complete and verify the NARS message.
County telecommunicators notify County officials and municipalities per SOP.
Counties implement public notification procedures and traffic and access control per SOPs, as applicable.
Mviunicipal Telecornmunicators complete and verify the NARS message.
Municipal Telecommunicators notify EOC staff.
1300 State EOC terminates exercise and notifies offsite locations that the exercise is terminated.
41