3.4 EMERGENCY COOLING Applicabilitv:

Applies to the operating status of the emergency cooling systems.

Objective:

To assure operability of the emergency cooling systems.

Specifications:

A.

Core Spray System NOTE: LCO 3.0.C.2 is not applicable to the Core Spray System I.

The Core Spray System shall be OPERABLE at all times with irradiated fuel in the reactor vessel with an absorption chamber water volume of at least 82,000 ft3 except as specified in Table 3.4. 1, or as noted below.

2.

If Specification 3.4.A. I is not met the reactor shall be PLACED IN the COLD SHUTDOWN CONDITION and no work shall be performed on the reactor or its connected systems which could result in lowering the reactor water level to less than 4'8"above TOP OF ACTIVE FUEL.

Table 3.4.1 Run or Startup Mode (except for low power physics testing)

Condition Requirement Provided:

Any active loop component The Reactor may remain in Both Emergency Diesel becomes inoperable.

operation for a period not to exceed Generators are OPERABLE.

-OR-15 Days.

Two or more active loop The Redundant active loop components in the same loop components within the same (System I or System 2) are loop as the inoperable inoperable provided no two components are verified components are redundant.

OPERABLE on a daily basis.

Specification 3.4.A13 is met unless only a core spray booster pump is inoperable.

One Emergency Diesel The Reactor may remain in All core spray equipment Generator is inoperable.

operation for a period not to exceed connected to the OPERABLE 7 Days.

emergency diesel generator is (Refer to Section 3.7.C.2)

OPERABLE.

OYSTER CREEK 3.4-1 Amendment No.:

S-, 145, 167.

211,l41,247 Corrected bv letter of 10/13/104