October 19, 2004 LICENSEE:

PPL Susquehanna, LLC (PPL)

FACILITY:

Susquehanna Steam Electric Station, Units 1 and 2 (SSES 1 and 2)

SUBJECT:

SUMMARY

OF SEPTEMBER 2, 2004, CATEGORY 1 MEETING WITH PPL TO DISCUSS LICENSEES AMENDMENT REQUESTS DATED SEPTEMBER 16, 2003, AND DECEMBER 22, 2003 (TAC NOS. MC0837, MC1659, MC1660 AND MC4431)

On September 2, 2004, a Category 1 public meeting was held between the Nuclear Regulatory Commission (NRC), and representatives of PPL and Framatome Advanced Nuclear Power (Framatome ANP) at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss PPLs (1) September 16, 2003, Unit 2 mid-cycle minimum critical power ratio safety limit (MCPRSL) amendment request, (2) proposed Unit 2 Cycle 13 (U2C13) MCPRSL changes, and (3) December 22, 2003, SSES 1 and 2, Oscillation Power Range Monitoring (OPRM) amendment request. A list of attendees is provided as Attachment 1.

PPL presented information [see Agencywide Documents Access and Management System (ADAMS) accession number ML042710373] that provided an overview of their MCPRSL calculation process with respect to channel bow as a function of exposure gradients in the reactor core. PPL states that the channel bow data, using the Cartech channel performance analysis, supports the validation of their proposed MCPRSLs for two-recirculation loop and single-recirculation loop operation. PPL also provided a description of their proposed U2C13 MCPRSL amendment request that would adopt (Framatome ANP) reload licensing methodologies for anticipated operational occurrences and accidents. The transition from PPL to Framatome ANP methodologies will not impact the linear heat generation rate/average planar linear heat generation rate limits in the core operating limits report or the MCRPSL in the technical specifications. Finally, PPL presented its technical basis for changing the OPRM bypass setpoint from 60 to 65 Mlb/hr [million-pound-mass per hour]. The revised setpoint will assure the OPRM is not bypassed when instabilities in the reactor could occur.

PPL concluded that (1) results from channel bow measurements allow the proposed mid-cycle amendment for U2C12 MCPRSL to be processed, (2) the future amendment for U2C13 involves the adoption of ANF methodologies consistent with other Framatome ANF customers and revised MCPRSLs, and (3) the proposed OPRM bypass setpoint change is appropriate.

One member of the public was in attendance. Public Meeting Feedback forms were not received.

CONTACT: R. Guzman, NRR 301-415-1030 rvg@nrc.gov

PPL Please direct any inquiries to Richard V. Guzman, Project Manager, at 301-415-1030, or rvg@nrc.gov.

/RA/

Richard V. Guzman, Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388 Attachments: 1. List of Attendees cc w/atts: See next page

ML042730528 OFFICE PDI-1/PM SRXB/SC PDI-1/SC NAME RGuzman FAkstulewicz RLaufer DATE 10/19/04 9/28/04 10/19/04

LIST OF ATTENDEES REVIEW MEETING WITH PPL SUSQUEHANNA, LLC (PPL)

REGARDING PROPOSED MINIMUM CRITICAL POWER RATIO SAFETY LIMIT CHANGES SEPTEMBER 2, 2004 - 9:00-12:00, O-14-B-8 NAME ORGANIZATION

1. Richard V. Guzman NRC/NRR/DLPM/PDI-1
2. Richard J. Laufer NRC/NRR/DLPM/PDI-1
3. Francis Akstulewicz NRC/NRR/DSSA/SRXB
4. Zena Abdullahi NRC/NRR/DSSA/SRXB
5. George Thomas NRC/NRR/DSSA/SRXB
6. Tai Huang NRC/NRR/DSSA/SRXB
7. Jeremy Tapp NRC/NRR/DSSA/SRXB
8. Mike Crowthers PPL
9. Chester Lehmann PPL
10. Andrew Dyszel PPL
11. John M. Kulick PPL
12. Jerry Holmes Framatome, ANP
13. Jerry Ingham Framatome, ANP
14. David Ney Pennsylvania Bureau of Radiation Production

Susquehanna Steam Electric Station, Units 1 and 2 cc:

Britt T. McKinney Vice President - Nuclear Site Operations PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467 Richard L. Anderson Vice President - Nuclear Operations PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467 Aloysius J. Wrape, III General Manager - Nuclear Assurance PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Terry L. Harpster General Manager - Plant Support PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 Robert A. Saccone General Manager - Nuclear Engineering PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467 Rocco R. Sgarro Manager - Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Walter E. Morrissey Supervising Engineer Nuclear Regulatory Affairs PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 Michael H. Crowthers Supervising Engineer Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Dale F. Roth Manager - Quality Assurance PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Luis A. Ramos Special Office of the President PPL Susquehanna, LLC 634 Salem Blvd., SSO Berwick, PA 18603-0467 Bryan A. Snapp, Esq Assoc. General Counsel PPL Services Corporation Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Supervisor - Document Control Services PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Richard W. Osborne Allegheny Electric Cooperative, Inc.

212 Locust Street P.O. Box 1266 Harrisburg, PA 17108-1266 Director - Bureau of Radiation Protection Pennsylvania Department of Environmental Protection P.O. Box 8469 Harrisburg, PA 17105-8469 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4 Berwick, PA 18603-0035 Regional Administrator, Region 1

Susquehanna Steam Electric Station, Units 1 and 2 cc:

U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Board of Supervisors Salem Township P.O. Box 405 Berwick, PA 18603-0035 Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803 Mr. Bryce L. Shriver President, PPL Generation, LLC and and Chief Operating Officer PPL Generation, LLC 769 Salem Boulevard, NUCSB3 Berwick, PA 18603-0467