Duke R. A. JONES c wPowere Vice President A Duke Energy Company Duke Power 29672 / Oconee Nuclear Site 7800 Rochester Highway Seneca, SC 29672 June 22, 2004 864 885 3158 864 885 3564 fax Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Oconee Nuclear Station Docket Nos. 50-269, 270 and 287 Generic Letter 88-17, Loss of Decay Heat Removal Gentlemen:

On October 17, 1988, the NRC issued Generic Letter 88-17 which requested each licensee to respond to eight recommended expeditious actions. These actions aided in correcting deficiencies in procedures, hardware, and training relating to prevention of loss of decay heat removal. This letter is a supplement to the response that Oconee submitted January 3, 1989 to expeditious action (7).

Expeditious action (7) states:

"Implement procedures and administrative controls that reasonably assure that all hot legs are not blocked simultaneously by nozzle dams unless a vent path is provided that is large enough to prevent pressurization of the upper plenum of the Reactor Vessel (RV)."

In the response submitted January 3, 1989, Oconee stated that hot leg nozzle dams are not used. However, due to steam generator replacement on Unit 2, hot leg Foreign Material Exclusion (FME) control plugs were used. These plugs were used to prevent debris disposition inside the pipe from cutting and welding of the hot legs to the new steam generators. They also prevented personnel working inside the hot leg from falling down into piping connected to the reactor. This usage is strictly for steam generator replacement activities only, and FME control plugs will be used again during the Unit 3 EOC21 RFO scheduled for the fall of 2004.

If there are any questions about this action, please call Graham Davenport at (864)-885-3044.

Very truly yours, A"-

R. A. Jones, Site Vice President Oconee Nuclear Station www. duke-energy. corn

U. S. Nuclear Regulatory Commission June 22, 2004 Page 2 xc:

W. D. Travers U. S. Nuclear Regulatory Commission Regional Administrator, Region II Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, GA 30303 L. N. 0ishan NRC Senior Project Manager (ONS)

U. S. Nuclear Regulatory Commission Mail Stop 0-8 H12 Washington, DC 20555-0001 M. E. Shannon Senior Resident Inspector (ONS)

U. S. Nuclear Regulatory Commission Oconee Nuclear Site Henry Porter Division of Radioactive Waste Management South Carolina Bureau of Land and Waste Management 2600 Bull Street Columbia, SC 29201