Correction to Technical Specifications for Amendment No. 267 (TAC MB8896). Table of Contents, Page III & Page 4 of Appendix C Updated to Correct Errors
ML041820232
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 06/23/2004
From: Vissing G
NRC/NRR/DLPM/LPD1
To: Vanderheyden G
Calvert Cliffs
References
TAC MB8896
Download: ML041820232 (2)


Text

TABLE OF CONTENTS 3.5.5 Trisodium Phosphate (TSP).........

................. 3.5.5-1 3.6 CONTAINMENT SYSTEMS.................................... 3.6.1-1 3.6.1 Containment........................................ 3.6.1-1 3.6.2 Containment Air Locks..............................

3.6.2-1 3.6.3 Containment Isolation Valves....................... 3.6.3-1 3.6.4 Containment Pressure...............................

3.6.4-1 3.6.5 Containment Air Temperature........................

3.6.5-1 3.6.6 Containment Spray and Cooling Systems..............

3.6.6-1 3.6.7 Deleted 3.6.8 Iodine Removal System (IRS)........

3.6.8-1 3.7 PLANT SYSTEMS.......................................... 3.7.1-1 3.7.1 Main Steam Safety Valves (MSSVs)......

3.7.1-1 3.7.2 Main Steam Isolation Valves (MSIVs)......

3.7.2-1 3.7.3 Auxiliary Feedwater (AFW) System...................

3.7.3-1 3.7.4 Condensate Storage Tank (CST).......

3.7.4-1 3.7.5 Component Cooling (CC) System......................

3.7.5-1 3.7.6 Service Water (SRW) System.........................

3.7.6-1 3.7.7 Saltwater (SW) System..............................

3.7.7-1 3.7.8 Control Room Emergency Ventilation System (CREVS).

3.7.8-1 3.7.9 Control Room Emergency Temperature System (CRETS).. 3.7.9-1 3.7.10 Emergency Core Cooling System (ECCS) Pump Room Exhaust Filtration System (PREFS).3.7.10-1 3.7.11 Spent Fuel Pool Exhaust Ventilation System (SFPEVS).3.7.11-1 3.7.12 Penetration Room Exhaust Ventilation System (PREVS).

....................................... 3.7.12-1 3.7.13 Spent Fuel Pool (SFP) Water Level..................

3.7.13-1 3.7.14 Secondary Specific Activity........................

3.7.14-1 3.7.15 Main Feedwater Isolation Valves (MFIVs)............

3.7.15-1 3.7.16 Spent Fuel Pool (SFP) Boron Concentration..........

3.7.16-1 3.8 ELECTRICAL POWER SYSTEMS...............................

3.8.1-1 3.8.1 AC Sources-Operating..........

3.8.1-1 3.8.2 AC Sources-Shutdown...........

3.8.2-1 3.8.3 Diesel Fuel Oil....................................

3.8.3-1 3.8.4 DC Sources-Operating.

3.8.4-1 3.8.5 DC Sources-Shutdown...........

3.8.5-1 3.8.6 Battery Cell Parameters............................

3.8.6-1 3.8.7 Inverters-Operating...........

3.8.7-1 3.8.8 Inverters-Shutdown............

3.8.8-1 CALVERT CLIFFS - UNIT 1 iii Amendment No. 267 CALVERT CLIFFS - UNIT 2 Amendment No. 239 Amendment No.

Additional Conditions Implementation Date 246 248 This amendment requires the licensee to incorporate in the Updated Final Safety Analysis Report (UFSAR) changes associated with the aircraft hazards analysis which was evaluated by the staff in the Safety Evaluation dated August 29, 2001.

This amendment requires the licensee to incorporate in the Updated Final Safety Analysis Report (UFSAR) changes associated with the loss of feedwater flow analysis which was evaluated by the staff in the safety evaluation dated February 26, 2002.

This amendment requires the licensee develop a long-term coupon surveillance program for the Carborundum samples. This program must verify that the Carborundum degradation rates assumed in the licensee's analyses to prove subcriticality, as required by 10 CFR 50.68, remain valid over the seventy-year life span of the Unit 1 spent fuel pool. The licensee must submit this modified coupon surveillance program to the NRC under the 10 CFR 50.90 requirements for its review and approval.

Next update of the UFSAR Next update of the UFSAR 3 years after approval of this amendment 267 Amendment No. 267