Issuance of Amendment Relocation of Pressurizer Maximum Heatup and Cooldown Limits
ML041760492
Person / Time
Site: Waterford Entergy icon.png
Issue date: 06/16/2004
From:
Office of Nuclear Reactor Regulation
To:
References
Download: ML041760492 (2)


Text

INDEX LIMITING CONDITION FOR OPERATION AND SURVEILLANCE REQUIREMENTS SECTION PAGE 3/4.4 REACTOR COOLANT SYSTEM 3/4.4.1 REACTOR COOLANT LOOPS AND COOLANT CIRCULATION STARTUP AND POWER OPERATION.3/4 4-1 HOT STANDBY.

314 4-2 HOT SHUTDOWN.3/4 4-3 COLD SHUTDOWN - LOOPS FILLED.

3/4 4-5 COLD SHUTDOWN - LOOPS NOT FILLED.3/4 4-6 314.4.2 SAFETY VALVES SHUTDOW N.....................................................................

3/4 4-7 OPERATING.....................................................................

3/4 4-8 3/4.4.3 PRESSURIZER PRESSURIZER.................................................................

3/4 4-9 AUXILIARY SPRAY...........................................

3/4 4-9a 314.4.4 STEAM GENERATORS...........................................

3/4 4-10 3/4.4.5 REACTOR COOLANT SYSTEM LEAKAGE LEAKAGE DETECTION SYSTEMS....................................

3/4 4-17 OPERATIONAL LEAKAGE............................................

3/4 4-18 3/4.4.6 CHEMISTRY............................................

3/4 4-21 3/4.4.7 SPECIFIC ACTIVITY............................................

3/4 4-24 3/4.4.8 PRESSURE/TEMPERATURE LIMITS REACTOR COOLANT SYSTEM.........................................

3/4 4-28 PRESSURIZER...................................................................

3/4 4-33 OVERPRESSURE PROTECTION SYSTEMS....................

3/4 4-34 3/4.4.9 DELETED............................................

3/4 4-36 3/4.4.10 REACTOR COOLANT SYSTEM VENTS...............................

3/4 4-37 3/4.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) 3/4.5.1 SAFETY INJECTION TANKS.3/4 5-1 3/4.5.2 ECCS SUBSYSTEMS - Modes 1, 2, and 3.3/4 5-3 3/4.5.3 ECCS SUBSYSTEMS - Modes 3 and 4.3/4 5-8 3/4.5.4 REFUELING WATER STORAGE POOL.3/4 5-9 WATERFORD - UNIT 3 VI AMENDMENT NO. 22, 34, 188, 148, 195

REACTOR COOLANT SYSTEM PRESSURIZER LIMITING CONDITION FOR OPERATION I

3.4.8.2 The pressurizer shall be limited to:

a. Deleted,
b. Deleted, and
c. A maximum spray nozzle usage factor of 0.65.

APPLICABILITY: At all times.

ACTION:

a. Deleted.
b. With the spray nozzle usage factor > 0.65, comply with requirements of Table 5.7-1.

SURVEILLANCE REQUIREMENTS I

4.4.8.2.1 Deleted.

4.4.8.2.2 The spray water temperature differential shall be determined to be within the limit at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> during auxiliary spray operation.

4.4.8.2.3 Each spray cycle and the corresponding &T (water temperature differential) shall be recorded whenever main spray is initiated with a AT (water temperature differential) of > 1300F and whenever auxiliary spray is initiated with a AT (water temperature differential) of > 140'F.

I WATERFORD - UNIT 3 3/4 4-33 AMENDMENT NO. 195