ML041620322

From kanterella
Jump to navigation Jump to search

Request for Additional Information, Alternative Source Term Amendment Request. TAC Nos. MB6530, MB6531, MB6532, and MB6533
ML041620322
Person / Time
Site: Dresden, Quad Cities  
(DPR-019, DPR-025, DPR-029, DPR-030)
Issue date: 06/15/2004
From: Rossbach L
NRC/NRR/DLPM/LPD3
To: Crane C
Exelon Generation Co
Rossbach L, 415-2863, NRR/DLPM
References
TAC MB6530, TAC MB6531, TAC MB6532, TAC MB6533
Download: ML041620322 (4)


Text

June 15, 2004 Mr. Christopher M. Crane, President and Chief Nuclear Officer Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3, AND QUAD CITIES NUCLEAR POWER STATION, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION (RAI) REGARDING ALTERNATIVE SOURCE TERM AMENDMENT REQUEST (TAC NOS. MB6530, MB6531, MB6532, AND MB6533)

Dear Mr. Crane:

By letter dated October 10, 2002, Exelon Generation Company (Exelon) submitted an amendment request to support application of an alternative source term (AST) at Dresden Nuclear Power Station, Units 2 and 3, and Quad Cities Nuclear Power Station, Units 1 and 2.

By letter dated August 4, 2003, Exelon responded to a Nuclear Regulatory Commission (NRC) staff request for additional information (RAI) on the meteorological data and atmospheric dispersion factors supporting the AST amendment request. By letter dated October 31, 2003, Exelon submitted corrected meteorological data in response to additional NRC RAIs on meteorology. On May 18, 2004, NRC staff informed your staff that we had identified concerns with the latest meteorological information submitted by Exelon. During a telephone call with your staff on May 26, 2004, your staff confirmed that there were errors in the meteorological data files and stated their intent to correct the errors and recalculate the atmospheric dispersion factors. During the May 26, 2004, telephone call NRC requested that the corrected meteorological information be submitted to NRC and that Exelon either verify that current NRC guidance in this area is being followed or provide justification for any deviations. On June 7, 2004, your staff agreed to respond to this RAI by August 3, 2004.

Please contact me at 301-415-2863 if your staff has any questions about this RAI.

Sincerely,

/RA/

Lawrence W. Rossbach, Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos.: 50-237, 50-249, 50-254, and 50-265 cc: See next page

June 15, 2004 Mr. Christopher M. Crane, President and Chief Nuclear Officer Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3, AND QUAD CITIES NUCLEAR POWER STATION, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION (RAI) REGARDING ALTERNATIVE SOURCE TERM AMENDMENT REQUEST (TAC NOS. MB6530, MB6531, MB6532, AND MB6533)

Dear Mr. Crane:

By letter dated October 10, 2002, Exelon Generation Company (Exelon) submitted an amendment request to support application of an alternative source term (AST) at Dresden Nuclear Power Station, Units 2 and 3, and Quad Cities Nuclear Power Station, Units 1 and 2.

By letter dated August 4, 2003, Exelon responded to a Nuclear Regulatory Commission (NRC) staff request for additional information (RAI) on the meteorological data and atmospheric dispersion factors supporting the AST amendment request. By letter dated October 31, 2003, Exelon submitted corrected meteorological data in response to additional NRC RAIs on meteorology. On May 18, 2004, NRC staff informed your staff that we had identified concerns with the latest meteorological information submitted by Exelon. During a telephone call with your staff on May 26, 2004, your staff confirmed that there were errors in the meteorological data files and stated their intent to correct the errors and recalculate the atmospheric dispersion factors. During the May 26, 2004, telephone call NRC requested that the corrected meteorological information be submitted to NRC and that Exelon either verify that current NRC guidance in this area is being followed or provide justification for any deviations. On June 7, 2004, your staff agreed to respond to this RAI by August 3, 2004.

Please contact me at 301-415-2863 if your staff has any questions about this RAI.

Sincerely,

/RA/

Lawrence W. Rossbach, Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos.: 50-237, 50-249, 50-254, and 50-265 cc: See next page DISTRIBUTION:

PUBLIC PDIII/2 r/f AMendiola LRossbach MBanerjee PCoates OGC ACRS MRing, RIII RDennig LBrown DLPM DPR ADAMS Accession Number: ML041620322 OFFICE PM:PD3-2 LA:PD3-2 SC:PD3-2 NAME LRossbach PCoates AMendiola DATE 06/15/04 06/15/04 OFFICIAL RECORD COPY

Dresden and Quad Cities Nuclear Power Stations cc:

Site Vice President - Dresden Nuclear Power Station Exelon Generation Company, LLC 6500 N. Dresden Road Morris, IL 60450-9765 Dresden Nuclear Power Station Plant Manager Exelon Generation Company, LLC 6500 N. Dresden Road Morris, IL 60450-9765 Regulatory Assurance Manager - Dresden Exelon Generation Company, LLC 6500 N. Dresden Road Morris, IL 60450-9765 U.S. Nuclear Regulatory Commission Dresden Resident Inspectors Office 6500 N. Dresden Road Morris, IL 60450-9766 Chairman Grundy County Board Administration Building 1320 Union Street Morris, IL 60450 Regional Administrator U.S. NRC, Region III 801 Warrenville Road Lisle, IL 60532-4351 Illinois Emergency Management Agency Division of Disaster Assistance &

Preparedness 110 East Adams Street Springfield, IL 62701-1109 Document Control Desk - Licensing Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Vice President - Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President of Operations - Mid-West Boiling Water Reactors Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director - Licensing and Regualtory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Associate General Counsel Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Manager Licensing - Dresden, Quad Cities and Clinton Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Site Vice President - Quad Cities Nuclear Power Station Exelon Generation Company, LLC 22710 206th Avenue N.

Cordova, IL 61242-9740 Quad Cities Nuclear Power Station Plant Manager Exelon Generation Company, LLC 22710 206th Avenue N.

Cordova, IL 61242-9740

Dresden and Quad Cities Nuclear Power Stations cc:

Regulatory Assurance Manager - Quad Cities Exelon Generation Company, LLC 22710 206th Avenue N.

Cordova, IL 61242-9740 Quad Cities Resident Inspectors Office U.S. Nuclear Regulatory Commission 22712 206th Avenue N.

Cordova, IL 61242 David C. Tubbs MidAmerican Energy Company One River Center Place 106 E. Second, P.O. Box 4350 Davenport, IA 52808-4350 Vice President - Law and Regulatory Affairs MidAmerican Energy Company One River Center Place 106 E. Second Street P.O. Box 4350 Davenport, IA 52808 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.

Rock Island, IL 61201