Final Exercise Report Grand Gulf Nuclear Station Licensee:
Exercise Date:
Report Date:
Entergy Operations, Inc.
September 17,2003 December 15,2003 FEDERAL EMERGENCY MANAGEMENT AGENCY REGION IV 3003 Chamblee-Tucker Road Atlanta, Georgia 30341
Federal Emergency Management Agency Region IV 3003 Chamblee-Tucker Road Atlanta, Georgia 30341 December 15, 2003 Mr. Ellis W. Merschoff Regional Administrator - RIV Nuclear Regulatory Commission Harris Tower 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064
Dear Mr. Merschoff:
Enclosed is a copy of the Grand Gulf Nuclear Station final exercise report for the September 17, 2003, full participation plume exposure pathway exercise of the offsite radiological emergency response plans and procedures site-specific to the Grand Gulf Nuclear Station. This report addresses the evaluation of the plans and preparedness for the State of Mississippi and Claiborne County, located within the 10-mile emergency planning zone, and the host counties of Copiah and Warren. The Federal Emergency Management Agency Region IV staff prepared the final exercise report for the State of Mississippi and its affected counties. Copies of this report will be forwarded to the State of Mississippi FEMA and NRC Headquarters by my staff. FEMA Region VI prepares the exercise report for the State of Louisiana and its affected local governments.
All agreed upon evaluation criteria for this exercise were demonstrated. No Deficiencies and only two Areas Requiring Corrective Action (ARCA) were identified during the exercise. The ARCAs involved the SEOC and Claiborne County concerning Alert and Notification of the public. The corrective action plan for the ARCAs is forthcoming from the State of Mississippi.
Based on the results of the September 17, 2003 exercise, and FEMA's review of Mississippi's Annual Letter of Certification for 2001 and 2002, the offsite radiological emergency response plans and preparedness for the State of Mississippi and the appropriate local jurisdictions site-specific to the Grand Gulf Nuclear Station can be implemented and are adequate to provide reasonable assurance that appropriate measures can be taken to protect the health and safety of the public in the event of a radiological emergency at the site. The 44 CFR Part 350 approval of the State of Mississippi's offsite radiological emergency response plans and preparedness site-specific to Grand Gulf Nuclear Station granted on Jun'e 23, 1983, will remain in effect.
Should you have questions, please contact Eddie Hickman at 770/220-5370.
K eth 9. Burns, Jr.
Regional Director Enclosure cc:
Ms. Vanessa E. Quinn, Chief' Federal Emergency Management Agency Headquarters Radiological and Emergency Preparedness Branch - NP-TS-RP 500 C Street, SWK,,Rponi2n
, h i i
Washinton,. C. *20472 S. Debra A. Schneck, Chief Emergency Preparednessand Health Physics Section Operators Licensing, Humnan Performrance and Plant Support Branch Division of Inspection Program Management Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555-0001 I "- I i
Final Exercise Report Grand Gulf Nuclear Station Licensee:
Exercise Date:
Report Date:
Entergy Operations, Inc.
September 17, 2003 December 15, 2003 FEDERAL EMERGENCY MANAGEMENT AGENCY REGION IV 3003 Chamblee-Tucker Road Atlanta, Georgia 30341
TABLE OF CONTENTS Page I.
EXECUTIVE
SUMMARY
1 II.
INTRODUCTION...................
2 III.
EXERCISE OVERVIEW............................................................................................... 4 A.
Plume Emergency Planning Zone Description..................................
4 B.
Exercise Participants................................
4 C.
Exercise Timeline...................................
5 IV.
EXERCISE EVALUATION AND RESULTS.......
........................ 7 A.
Summary Results of Exercise Evaluation - Table 2................................
7 B.
STATUS OF JURISDICTIONS EVALUATED
................................. 9
- 1.
STATE OF MISSISSIPPI...............................
10 1.1 State Emergency Operations Center........................................ 10 1.2 Emergency Operations Facility/Dose Assessment........................ 11 1.3 Emergency News Media Center...............................
......... 12 1.4 Radiological Health........................................
13 1.5 Radiological Field Monitoring Teams........................................ 13 1.6 State Traffic Control Points........................................
14
- 2.
RISK JURISDICTION...............
15 2.1 CLAIBORNE COUNTY........................................
15 2.1.1 Emergency Operations Center........................................ 15 2.1.2 Traffic and Access Control........................................
16 2.1.3 Protective Action for Schools........................................ 16 2.1.4 Emergency Worker Monitoring & Decontamination........
17
- 3.
HOST JURISDICTIONS................
17 3.1 COPIAH COUNTYY................................
17 3.1.1 Reception and Congregate Care...............................
17 i
3.2 WARREN COUNTY.....................................
18 3.2.1 Temporary Care.....................................
18 3.2.2 Emergency Worker Equipment Monitoring and Decontamination.....................................
19 3.2.3 Medical Service Drill (MS-i).....................................
19
- 4.
SUMMARY
OF AREAS REQUIRING CORRECTIVE ACTION.
21 4.1 2003 ARCAs.................................
21 4.1.1 28-03-5.a.1-A-01 SEOC.................................
21 4.1.2 28-03-5.a.1-A-02 Claiborne County EOC....................... 22
=
4.2 PRIOR ARCAS - RESOLVED 23 4.2.1 28-02-5.b.1-A-03 ENMC.................................
23 List of Appendices APPENDIX I - ACRONYMS AND ABBREVIATIONS 25 APPENDIX 2 - EXERCISE EVALUATORS.27 APPENDIX 3 - EXERCISE CRITERIA AND EXTENT-OF-PLAY AGREEMENT.29 APPENDIX 4 - EXERCISE SCENARIO.30 List of Tables Table I -
Exercise Timeline......................
6 Table 2 -
Summary of Exercise Evaluation......................
8 ii
I.
EXECUTIVE
SUMMARY
On September 17, 2003, the Federal Emergency Management Agency (FEMA), Region IV and VI, conducted a full participation plume exposure pathway exercise in the emergency-planning zone (EPZ) around the Grand Gulf Nuclear Station (GGNS). A separate report is prepared by Region VI concerning the evaluation of the State of Louisiana and Tensas Parish. The purpose of the exercise was to assess the level of State and local preparedness in responding to a radiological emergency. This exercise was held in accordance with FEMA's policies and guidance concerning the exercise of State and local radiological emergency response plans (RERP) and procedures.
The most recent exercise at this site was conducted on March 6, 2002. The qualfying emergency preparedness exercise was conducted November 4-5, 1981 at the GGNS.
The State of Mississippi the risk County of Claiborne County and the host Counties of Copiah and Warren participated in this exercise. FEMA Region IV wishes to acknowledge the exceptional efforts of the many individuals who planned, prepared for and participated in this exercise. Protecting the public health and safety is the full-time job of some of the exercise participants and an assigned responsibility for others. Others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities. The cooperation and teamwork of all participants demonstrated the quality of training and preparation.
This report contains the evaluation of the exercise on September 17, 2003, as well as out-of-sequence activities conducted in June 2003, which included: traffic and access control, protective action for schools, registration and temporary care of evacuees and a medical service drill.
The State and local organizations demonstrated knowledge of, and the ability to implement, their emergency response plans and procedures. No Deficiency was identified, however, two Areas Requiring Corrective Action (ARCA) were identified at the SEOC and Claiborne County concerning Alert and Notification of the public. One ARCA previously identified at the Emergency News Media Center was corrected.
I
II.
INTRODUCTION On December 7, 1979, the President directed FEMA to assume the lead responsibility for all offsite nuclear planning and response. FEMA's activities are conducted pursuant to Title 44 Code of Federal Regulations (CFR) Parts 350, 351 and 352. These regulations are a key element in the Radiological Emergency Preparedness (REP) Program that was established following the Three Mile Island Nuclear Station accident in March 1979.
Title 44 CFR 350 establishes the policies and procedures for FEMA's initial and continued approval of State and local governments' radiological emergency planning and preparedness for commercial nuclear power plants. This approval is contingent, in part, on State and local government participation in joint exercises with licensees.
FEMA's responsibilities in radiological emergency planning for fixed nuclear facilities (FNF) include the following:
Taking the lead in offsite emergency planning and in the review and evaluation of radiological emergency response plans (RERP) and procedures developed by State and local governments; Determining whether such plans and procedures can be implemented on the basis of observation and evaluation of exercises of the plans and procedures conducted by State and local governments; Responding to requests by the Nuclear Regulatory Commission (NRC) pursuant to the Memorandum of Understanding between the NRC and FEMA (Federal Register, Vol. 58, No. 176, September 14, 1993).
Coordinating the activities of Federal agencies with responsibilities in the radiological emergency planning process:
Department of Agriculture Department of Commerce Department of Energy Department of Health and Human Services Department of the Interior Department of Transportation Environmental Protection Agency Food and Drug Administration and Nuclear Regulatory Commission.
Representatives of these agencies serve on the FEMA Region IV Regional Assistance Comrnittee (RAC), which is chaired by FEMA.
2
Formal submission of the RERPs for the GGNS to FEMA Region IV by the State of Mississippi was made on May 22, 1981. Formal approval of these RERPs was granted on June 29, 1983, under Title 44 CFR 350.
A REP exercise was conducted on September 17,2003, by FEMA Regions IV and VI to assess the capabilities of State and local emergency preparedness organizations in implementing their RERPs and procedures to protect the public health and safety during a radiological emergency involving the GGNS. This report presents the exercise results and findings for the State of Mississippi and its counties on the performance of the offlite response organizations (ORO) during a simulated radiological emergency.
The findings presented in this report are based on the evaluations of the Federal evaluator team, with final determinations being made by the FEMA Region IV RAC Co-Chair and Chief Evaluator with final approval by the Regional Director.
The criteria utilized in the FEMA evaluation process are contained in:
NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980; FEMA-REP Exercise Evaluation Methodology, April 25, 2002.
Section III, entitled "Exercise Overview," presents basic information and data relevant to the exercise. This section contains a description of the plume pathway EPZ, a listing of all participating jurisdictions and functional entities that were evaluated, and a table presentation of the time of actual occurrence of key exercise events and activities.
Section IV, entitled "Exercise Evaluation and Results," presents summary information on the demonstration of applicable exercise criterion at each jurisdiction or functional entity evaluated in a results only format.
3
III.
EXERCISE OVERVIEW Contained in this section are data and basic information relevant to the September 17, 2003 exercise to test the offsite emergency response capabilities in the area surrounding the GGNS, in the State of Mississippi A.
Plume Emergency Planning Zone Description The GGNS is owned and operated by Entergy Operations Inc. It is located near the City of Port Gibson in Claiborne County, Mississippi.
Portions of Claiborne County, Mississippi and Tensas Parish, Louisiana, are located in the 10-mile emergency planning zone (EPZ). The land in the Mississippi EPZ is primarily agricultural in nature. The only major recreation area in the 10-mile EPZ is Grand Gulf State Park, located one mile east of the plant. The major transportation facilities in the EPZ include the Mississippi River, US Highway 61, State Highways 27, 18 and 547 and the Natchez Trace Parkway. The 10-mile EPZ includes 11 protective action areas.
B.
Exercise Participants The following agencies, organizations, and units of government participated in the GGNS exercise on September 17, 2003.
STATE OF MISSISSIPPI Board of Animal Health Department of Agriculture and Commerce Department of Environmental Quality Department of Extension Service Department of Humans Services Department of Mental Health Department of Transportation Department of Wildlife, Fisheries and Parks Development Authority/Energy Division Division of Radiological Health Emergency Management Agency Forestry Commission Highway Patrol Military Department RISK JURISDICTION Claiborne County 4
HOST JURISDICTIONS Copiah County Warren County PRIVATENOLUNTEER ORGANIZATIONS American Red Cross Salvation Army C.
Exercise Timeline Table 1, on the following page, presents the time at which key events and activities occurred during the GGNS exercise on September 17, 2003.
5
I I
I I f I
[
[
I I
I I
r r
I I
r r
I Table 1. Exercise Timeline DATE AND SITE: September 17,
~
g 11 r<_Lww I 1 SEOC MDRH ENMC CLAIBORNE COUNTY LA STATE TENASAS PARISH Unusual Event 0811 0835 0835 0835 0830 0827 Alert 0919 0937 0937 0937 0930 0925 0025 Site Area Emergency 1045 110S 110 1104 1125 1110 1130 Generl Emergency 1126 1149 1149 1129 1152 1148 1150 Simulated Rad. Release Started 1155 1220 1220 1200 1215 1218 Simulated Rad. Release Terminated On-going On-going Of-going On-going On-going Facility Declared Operational 1026 1026 1020 0930 0945 1055 Declaration of State of Emergency 1105 1105 1139 1130 1025 0944 Exercise Terminated 1408 1408 1403 1410 1406 Early Precautionary Actions:
Close Air Space and Mississippi River 1126 1122 1121 Relocate students and Specials needs population. establish 1110 V" Siren Activation 1143 1210 Media Briefing 1150 I" Protective Action Decision 1147 Evacuate PPAs: 2 mile radius, areas I & 7 to 5 miles 1158 1158 Shelter PPAs: Rest of 10-mile EPZ 2nd Siren Activation 1200 1200 1210 EAS Message 1205 1205 1210 2d Protective Action Decision 1309 Evacuate PPAs: 1, 2a, 2b & 7 1312 Shelter PPAs: Remaining 10-mile 3r" Siren Activation 1315 1315 EAS Message 1315 1315 KI Decision: Emergency workers ingest 1225 1229 PPA - Protective Action Area
IV.
EXERCISE EVALUATION AND RESULTS Contained in this section are the results and findings of the evaluation of Mississippi Jurisdictions and functional entities, which participated in the September 17, 2003, exercise to test the offsite emergency response capabilities of State and local governments within the 10-mile EPZ around the GGNS.
Each jurisdiction and functional entity was evaluated on the basis of its demonstration of criteria delineated in REP Exercise Evaluation Methodology, dated April 25, 2002.
Detailed information on the exercise criteria and the extent-of-play agreenent used in this exercise are found in Appendix 3 ofthis report.
A.
Summary Results of Exercise Evaluation - Table 2 The matrix presented in Table 2, on the following page, presents the status of all exercise criteria that were scheduled for demonstration during this exercise, by all participating jurisdictions and functional entities. Exercise criteria are listed by number. The demrnstration status ofthose criteria is indicated by the use ofthe following letters:
M Met (No Deficiency or ARCAs assessed and no unresolved ARCAs from prior exercises)
D Deficiency assessed A
ARCA(s) assessed or unresolved ARCA(s) from prior exercise(s)
N Not Demonstrated (Reason explained in Subsection B) 7
II II I
I r
I I
I I
I I
I I
II Table 2. Summary of Exercise Evaluation DATE AND SITE: September 17, 2003 - Grand Gulf Nuclear Station ELEMENT/Sub-Element MEMA MSDH/DRH EOF ENMC CLAIBORNE COPIAH WARREN
- 1. EMERENCY OPERATIONS MANAGEMENT I.a.l. Mobilization M
M M
I.b. 1. Faciliies M
M M
M M
I.c.2. I eDirection and Control f
M M
M M
M I.d.l. CommunicationsEquipment M
M M
M M
I.e. I. ERuipdement SUDplies to SUPaOrt Oerations M
MRecaiRnty
- 2. PROTECTIVE ACTION DECISION MAKING 2.a.1. Emerggncy Workr ExPOSUre Control M
M M
M 2.b. 1. Rad Assessment and PARo Based on Available Info M
M 2;b.2. Rad Assessment and PADs for the General Public M
M M
2.c.1. Protective Action Decisions for Special Populbtiont M
2.d. 1. Rad Assessment Decision Maoa ing for Ingestion Exposure 2.e.2. Rad Assessment t
Decision Making fof Relacation Re-entry &
Return
- 3. PROTECTIVE5 ACTION IMPLEMENTATION 3.a. 1. Implementation of Energency Worker Control M
M M
M 3.b.2. 1.Imvlementation of KI Decisions M
M 3.c.
In. smdementrtion of PADs for Special Powhtions 3.c.2. Implementation of PADs for Scheoeo M
3.d. 1. Implementation of Trafc and Access Control M
M 3.d.2. Impediments to Evacuation and Traffc and Access Control M
M 3.e.. Implemenation of Ingestion Decisions Using Adequite Info M
3.e.2. Implehlentation of aP Decisions ShoMving Stategies and Instructional Materials.
3.f. 1. Implementation of Relocation, Re-entry and Return Decisions
- 4. FIELD MEASUREMENT end ANALYSIS 4.a. 1. Plume Phase Field Measurement h Analysis Equipment 4.a.2. Plume Phase Field Measurement h Analysis Management
_M 4.a.3. Plume Phase Field Measurements & Analysis Procedures M
4.b. 1. Post Plume Field Measurement & Analysis 4.b.2. Laboratory Operations S. EMERGENCY NOTIFICATION i PUBLIC INFO 5.a. 1. Activation of Prompt Alert and Notification A
A 5.a.2. Activation of Prompt Alert and Notification 15-Minute (Fast Breaker) 5.a.3. Activation of Prompt Alert and Notification Backup Alert and Notification 5.b. 1. Emergency Info and Instructions for the Public and the Media
_M M
M_
- 6. SUPPORT OPERATIONSIFACILITIES 6.a. 1. Monitoring and Decon of Evacuees and EWs and Registration of M
M M
Evacuees 6.b. 1. Monitoringiand Decon of Emergency Worker Equipment M
6.c. 1. Temporary Care of I 6.d. 1. Transport and Treati cuees tnof(
o m
tIsI I
I I
I M
M Cornxtminated Injured Individu ls I_
M II LEGEND:
M - Met Criterion A - ARCA
B.
Status of Jurisdictions Evaluated This subsection provides information on the evaluation of each participating jurisdiction and functional entity in a results based format. Presented below is a definition of the terms used in this subsection relative to criterion demonstration status.
Met -Listing of the demonstrated exercise criteria under which no Deficiencies or ARCAs were assessed during this exercise and under which no ARCAs assessed during prior exercises remain unresolved.
Deficiency - Listing ofthe demonstrated exercise criteria under which one or more Deficiencies were assessed during this exercise. Included is a description of each Deficiency and recommended corrective actions.
Area Requiring Corrective Actions - Listing of the demonstrated exercise criteria under which one or more ARCAs were assessed during the current exercise or ARCAs assessed during prior exercises that remain unresolved. Included is a description ofthe ARCA assessed during this exercise and the recommended corrective action to be demonstrated before or during the next biennial exercise.
Not Demonstrated -Listing ofthe exercise criteria, which were not demonstrated as scheduled during this exercise and the reason, they were not demonstrated.
Prior ARCAs - Resolved - Description(s) of ARCA(s) assessed during previous exercises, which were resolved in this exercise and the corrective actions demonstrated.
Prior ARCAs - Unresolved - Description(s) of ARCA(s) assessed during prior exercises, which were not resolved in this exercise. Included is the reason the ARCA remains unresolved and recommended corrective actions to be demonstrated before or during the next biennial exercise.
The following are definitions of the two types of exercise issues, which may be discussed in this report.
A Deficiency is defined in FEMA-REP-14 as "
an observed or identified inadequacy of organizational performance in an exercise that could cause a finding that offsite emergency preparedness is not adequate to provide reasonable assurance that appropriate protective measures can be taken in the event of a radiological emergency to protect the health and safety of the public living in the vicinity of a nuclear power plant."
An ARCA is defined in FEMA-REP-14 as "...an observed or identified inadequacy of organizational performance in an exercise that is not considered, by itself to adversely impact public health and safety."
9
- 1.
STATE OF MISSISSIPPI 1.1 State Emergency Operations Center The State Emergency Operations Center (SEOC) staff worked well as a team. The Chief of Operations effectively managed the exercise providing periodic briefings and direction and control to all participants. Staff briefings including updates from the utility representative were timely and informative. All Emergency Support Functions (ESF) were actively involved in respective responsibilities and encouraged to provide feedback. The Director and deputy participated in the decision making process. The Public Information Officer (PIO) and staff were actively involved in the exercise. When the primary communication circuit with the nuclear plant was disabled, the SEOC staff used the backup system to obtain critical information.
- a.
MET: Criteria L.a.1, I.b.1, 1.c.1, 1.d.1, L.e. 1, 2.a.1, 2.b.2 and 5.b.1
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION:
Issue No.: 028-03-5.a.1-A-01 Condition: The State of Mississippi did not follow its procedures to verifir that Claiborne County had received the notification of the Site Area Emergency (SAE) classification. The State also released information on the protective action for schools prior to the time that Claiborne County implemented the relocation of the schools.
At 1109, the State called Claiborne County over the "operational hotline."
Although, GGNS declared a SAE at 1045, Claiborne County had not received the information and the State did not verify with the County that they were aware of the change in Emergency Classification Level (ECL). The discussion between the Claiborne County Civil Defense Director (CCCDD) and the Director of the Mississippi Department of Radiological Health concerned the actions that would be taken in the event of an escalation to a General Emergency (GE). The State stated that they would order the evacuation of protective action areas (PPA)1 and 7 and shelter the remainder of the Mississippi EPZ if the plant declared a GE.
The State issued an Emergency Alert System (EAS) message at 1110 stating that the "precautionary transfer of special needs citizens and school children" had been directed. However, Claiborne County did not initiate the actions until 1122. A news release concerning the SAE that gave the similar information to the EAS message, was also released at 1110.
Possible Cause: State personnel did not follow procedures to verify that Claiborne County had received ECL information and initiated actions.
10
Reference:
NUREG-0654, E.5; 6 and 7. Mississippi Radiological Emergency Preparedness Plan (MREPP), Annex C, pages C-2 and C-3, paragraph C-2.
Effect: The County government's ability to take appropriate action to support the response to the accident is limited to the information it has received. Without verifying that the county has received the change in ECL the State may be unaware that the county has not implemented actions dictated by the ECL.
Recommendations: Review notification procedures and revise as necessary to ensure that State verifies that Claiboome County has received ECL information and that the county has taken appropriate actions at each ECL. Provide training to appropriate staff.
Schedule of Corrective Actions: On the date this report was published, the State Schedule of Corrective Actions was not available.
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE L
PRIOR ARCAs -UNRESOLVED:
NONE 1.2 Emergency Operations Facility/Dose Assessment The Grand Gulf Emergency Operations Facility (EOF) i's an excellent facility from which all participating response organizations can effectively manage emergency operations.
Communications and coordination among the State officials deployed to the EOF and the utility were exemplary. The State staff deployed to the EOF effectively performed independent accident analyses, to include radiological dose assessment; developed and recommended appropriate protective actions, provided direction and control for the State's radiological field monitoring teams, and kept the SEOC in Mississippi fully informed of all technical developments.
- a.
MET: Criteria l.b.I, I.c.l, I.d.l, L.e.I and 2.b.I
- h.
DEFICIENCY: NONE C.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE L
PRIOR ARCAs -UNRESOLVED:
NONE 11
1.3 Emergency News Media Center The Emergency News Media Center (ENMC) staff demonstrated a high degree of training and preparedness in their operation. Improvements in several areas, and the incorporation of numerous recommendations from the last evaluated exercise, were very evident. Most notable was the increased interaction between utility, State and local personnel, and the amount of coordination occurring between the ENMC's Mississippi Deputy Lead PIO and the Lead PIO in the SEOC. Activation of the ENMC was timely. Material presented in the three media briefings was consistent with news releases'and focused on the protection of the public. The Emergency Information Center (EIC) within'the ENMC fielded over 400 inquiries, identified trends, and alerted the utility spokesperson to rumors so he and the State representatives could clarify and correct incorrect information.
- a.
MET: Criteria l.b.l, I.c.l, L.d.l, L.e.1, 2.a.1, 3.a.1I 3.b.I and 5.b.I Lb.
DEFICIENCY: NONE
- c.
AREAS REQUIRING COIRRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED:
Issue No.: 028-02-5.b.I-A-03
==
Description:==
The 1140 protective action decision (PAD) was to evacuate Protective Action Areas' (PAAs) I and 5a and to shelter-in-place the remainder of the EPZ. The information provided to the public was inconsistent with this decision. The 1150 EAS message stated:
Government authorities have directed the following action for residents of the Claiborne County area; Evacuation in the following Protective Action Areas:
2 miles within Area 1 - Between Big Black River and Bayou Pierre west of Old Grand Gulf Road 5 miles within Area Sa -
Between Bayou Pierre and Russum Westside Road, east to Widow's Creek.
Shelter-in place the remaining 10 mile EPZ is sectors K, L and M.
The accompanying New Release included the information above and in the following sentence stated: "The remaining 10-mile EPZ is directed to shelter-in-place." The Mississippi spokesperson during the 1210 news conference stated that the shelter-in-place instruction was for the remaining EPZ not just sectors K, L and M. The reference to sectors K, L and M is not consistent with the information 12
provided to the public in the 2002 GGNS Emergency Public Information Brochure, which only identifies the PAAs.
Corrective Action Demonstrated: All EAS messages, news releases, and media briefings addressed geographical areas as described in the 2003 GGNS Emergency Public Information Brochure, (i.e., as PAAs). During the media briefings the State and County/Parish spokespersons correctly provided information to the media that was consistent with the PADs using the appropriate terminology. When referring to the PAAs, spokespersons also provided a description of the PAAs consistent with literature.
L PRIOR ARCAs - UNRESOLVED: NONE 1.4 Radiological Health The Mississippi Division of Radiological Health (DRH) Accident Assessment Team was co-located with MEMA in the SEOC. The Accident Assessment Team was comprised of the DRH Director, two physicists from DRH, and a utility liaison. They were professional and well trained. They developed protective action recommendations (PAR) in a timely and professional manner based upon available information and were proactive in keeping abreast of a changing situation. The DRH Director gave excellent briefings to the SEOC on plant conditions and the rational for the PARs.
- a.
MET: Criteria 1.a.l, lb. 1, 1.c. 1, 1.d. 1, L.e., 2.a. 1, 2.b. 1, 2.b.2, 3.a. I and 4.a.2
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE L
PRIOR ARCAs - UNRESOLVED: NONE 1.5 Radiological Field Monitoring Teams Both field monitoring teams (FMT) did an excellent job conducting pre-operational checks to assure a complete inventory of equipment and supplies, including appropriate dosimetry and potassium iodide (KI), and the operability of radiological instrumentation. The FMTs demonstrated proper exposure control techniques including knowledge of turn back values. They also successfully demonstrated the appropriate use of equipment and procedures to determine field radiation measurements. The measurements included ambient radiological readings, measurements of airborne radio iodine concentrations in the presence of noble gasses and obtaining samples of particulate activity in the airborne 13
plume. Both teams displayed a sense of purpose and professionalism throughout the conduct of the exercise.
- a.
MET: Criteria 1.d.l, L.e.1, 3.a.1, 3.b.1, 4.a.1, 4.a.2 and 4.a.3
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs -UNRESOLVED:
NONE 1.6 State Traffic Control Points The Mississippi Highway Patrol and Mississippi Department of Transportation demonstrated traffic control points (TCP) and traffic support through interviews at the Claiborne County Emergency Operafions Center (EGG). Both law enforcement officers and transportation personnel were knowledgeable of duties to include traffic impediments, dosimetry use, turn back values, exposure record and evacuation routes.
- a.
MET: Criteria 3.a.l, 3.b.1, 3.d.I and 3.d.2
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE L
PRIOR ARCAs - UNRESOLVED: NONE 14
- 2.
RISK JURISDICTION 2.1 CLAIBORNE COUNTY 2.1.1 Emergency Operations Center The EOC is an effective operation. Al ESFs were on-site for excellent coordination and cooperation during the exercise. Communications were received and distributed in a timely manner. Elected officials were present in the EOC for early and coordinated decision making. Public information was disseminated by the PIO upon decision by the EOC Director. At 1229, it was announced in the EOC that KI had been recommended for emergency workers and that the information should be relayed to those in the field.
- a.
MET: Criteria 1.a. 1, 1.b. 1, 1.c. 1, 1.e. 1, 2.a. 1, 2.b.2 and 5.a.3
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION:
Issue No.: 28-03-5.a.1-A-03 Condition: Sirens were sounded prior to a media press conference at 1150 without coordination with any of the required parties for decision-making, including any elected officials at the EOC, and without discussion of information to be disseminated to the public.
Possible Cause: The County PIO notified the Director of a press conference at 1150 and they needed to sound the sirens. The communicator was instructed to sound the sirens at 1 143, prior to the press conference. Coordination with the State for sounding of the sirens at 1 143 was not done. There was also no conversation pertaining to the content of information being presented to the media or public.
Reference:
Claiborne County Basic Plan Sections D and E; Annex C Section Il-A page C-I., paragraph 2.
Effect: The public would have heard the sirens without the benefit of any instructions for them to follow. This has the potential to cause public panic and overload the 911 system with calls from local citizens.
Recommendation: That, if present, elected officials should be included in all calls on the Alert Notification System (ANS), in addition to the operations manager of the EOC. Sirens should never be sounded without prior coordination with required parties, i.e. MEMA and Mississippi State Department of Health/DRH.
15
Schedule of Corrective Actions: The decision-makers present in the Claiborne County EOC at the time of the ANS phone message will hear the message along with the Director over a speaker phone. Sirens will not be sounded without prior coordination with required parties.
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE f
PRIOR ARCAs - UNRESOLVED: NONE 2.1.2 Traffic and Access Control Port Gibson provided two police officers and personnel from the city road maintenance department to demonstrate traffic and access control. Police officers and maintenance personnel were knowledgeable of their duties to include traffic impediments and the use of dosimetry, KI and monitoring equipment.
- a.
MET: Criteria 3.a. ], 3.b. 1, 3.d. 1 and 3.d.2
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
- f.
PRIOR ARCAs - UNRESOLVED: NONE 2.1.3 Protective Action for Schools Five bus drivers were interviewed at the EOC. They were knowledgeable of their duties and responsibilities to include dosimetry and KI. Buses are escorted by police officers.
Students are transported to Hazelhurst High SchooL Pagers with a special code are used to alert bus drivers to report to the school in the event of an emergency.
- 2.
MET: Criterion 3.c.2
- b.
DEFICIENCY: NONE C.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE 16
- e.
PRIOR ARCAs - RESOLVED: NONE L
PRIOR ARCAs - UNRESOLVED: NONE 2.1.4 Emergency Worker Monitoring & Decontamination The emergency worker monitoring and decontamination station was demonstrated by the Claiborne County Fire Department at the Pattison Fire Station. Two vehicles and four emergency workers were monitored. One vehicle and two workers were found to have contamination. The contaminated individuals were decontaminated and provided alternate clothing. The monitors were extremely knowledge about their responsibilities, including monitoring of vehicles and people, and providing several alternate methods for decontamination. They were aware of their dosimeters, and exposure limits and if required, the use of KI.
- a.
MET: Criteria I.e. I, 3.a.1, 6.a. and 6.b. I
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE L
PRIOR ARCAs-UNRESOLVED: NONE
- 3.
HOST JURISDICTIONS 3.1 COPIAH COUNTY 3.1.1 Reception and Congregate Care The demonstration of monitoring and registration of evacuees was conducted at Hazelhurst High SchooL The facility affords sufficient space to accomplish the monitoring, decontamination and registration of evacuees arriving from affected areas surrounding the GGNS. Volunteers from the Copiah County Emergency Management Agency (EMA) and Hazelhurst Fire Department staff this operation. The training, dedication and proficiency of the volunteers resulted in an excellent demonstration of their capabilities. The staff was very knowledgeable about dosimetry, contamination control, and the care of evacuees. Volunteers from the fire department and EMA are to be commended for this excellent operation.
17
The capability to care for up to 1000 evacuees was successfully demonstrated at Hazelhurst High School in Copiah County. Facilities, supplies and equipment are sufficient, as is staffing by American Red Cross (ARC) volunteers. Procedures are in place to obtain and maintain pertinent evacuee information, and to insure contaminated evacuees do not enter the shelter. All personnel were highly professional and motivated.
- a.
MET: Criteria L.e.1, 3.a.1, 6.a.I and 6.c.1
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE C.
PRIOR ARCAs - RESOLVED: NONE e
PRIOR ARCAs-UNRESOLVED: NONE 3.2 WARREN COUNTY 3.2.1 Temporary Care ARC, Department of Social Services (DSS) and a host of volunteers effectively demonstrated registration of six evacuees into the shelter. The shelter was equipped to accommodate the needs of individuals to include family members. The shelter manager was knowledgeable of ARC policy and procedures. Volunteers are to be commended for their outstanding participation during this exercise.
- a.
MET: Criteria I.b. 1, 6.a. I and 6.c. 1
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE L
PRIOR ARCAs - UNRESOLVED: NONE 18
3.2.2 Emergency Worker Equipment Monitoring and Decontamination The Warren County Emergency Management Agency, Vicksburg Fire Department, ARC, DSS, Warren Yazoo Mental Health Services and a host of volunteers effectively demonstrated monitoring and decontamination of emergency workers, equipment, and registration of evacuees. Emergency workers demonstrated proper monitoring techniques and registration of evacuees. Individuals were knowledgeable regarding dosimetry and KI. Two vehicles and six individuals were monitored and decontaminated. A special recognition should be given to all of the volunteers for the excellent job they did during the exercise.
- a.
MET: Criteria L.e.l, 3.a.I, 6.a.I and 6.b.l
- b.
DEFICIENCY: NONE
- c.
AREAS REQUIRING CORRECTIVE ACTION: NONE
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE f
PRIOR ARCAs - UNRESOLVED: NONE 3.2.3 Medical Service Drill (MS-1)
On June 12, 2003, a medical services drill was conducted to evaluate the response of the River Region Medical Center emergency room (ER) staff and the Vicksburg Fire Department Emergency Medical Service (EMS). The medical center was prepared to receive, monitor, decontaminate and treat the patient. The transfer of the patient was proper and prompt, with all appropriate information given to ER staff. The doctor assisted by two nurses assessed the patient's condition and established priorities for treatment of injuries and decontamination. Monitoring and decontamination procedures were appropriate, samples were taken and recorded. The ER staff performed well as a team. Exit procedures were appropriately demonstrated. The EMS crew was monitored, demonstrated appropriate exit procedures, and discussed where they would go to be decontaminated. All individuals from the EMS and medical center knew their duties and responsibilities, and performed them in a professional manner.
- a.
MET: Criteria l.e.I, 3.a. and 6.d. I
- b.
DEFICIENCY: NONE C.
AREAS REQUIRING CORRECTIVE ACTION: NONE 19
- d.
NOT DEMONSTRATED: NONE
- e.
PRIOR ARCAs - RESOLVED: NONE
£ PRIOR ARCAs - UNRESOLVED: NONE 20
-I
- 4.
SUMMARY
OF AREAS REQUIRING CORRECTIVE ACTION 4.1 2003 ARCAs 4.1.1 28-03-5.a.1-A-01 Condition: The State of Mississippi did not SEOC follow its procedures to verify that Claiborne County had received the notification of the Site Area Emergency (SAE) classification.
The State also released information on the protective action for schools prior to the time that Claiborne County implemented the relocation of the schools.
At 1109, the State called Claiborne County over the "operational hotline." Although, GGNS declared a SAE at 1045, Claiborne County had not received the information and the State did not verify with the County that they were aware of the change in Emergency Classification Level (ECL). The discussion between the Claiborne County Civil Defense Director (CCCDD) and the Director of the Mississippi Department of Radiological Health concerned the actions that would be taken in the event of an escalation to a General Emergency (GE). The State stated that they would order the evacuation of protective action areas (PPA) I and 7 and shelter the remainder of the Mississippi EPZ if the plant declared a GE.
The State issued an Emergency Alert System (EAS) message at 1110 stating that the "precautionary transfer of special needs citizens and school children" had been directed. However, Claiborne County did not initiate the actions until 1122. A news release concerning the SAE that gave the similar information to the EAS message, was also released at 1 1 10.
Possible Cause: State personnel did not follow procedures to verify that Claiborne County had received ECL information and initiated actions.
21
Reference:
NUREG-0654, E.5; 6 and 7.
Mississippi Radiological Emergency Preparedness Plan (MREPP), Annex C, pages C-2 and C-3, paragraph C-2.
Effect: The County government's ability to take appropriate action to support the response to the accident is limited to the information it has received. Without verifying that the county has received the change in ECL the State may be unaware that the county has not implemented actions dictated by the ECL.
Recommendations: Review notification procedures and revise as necessary to ensure that State verifies that Claiborne County has received ECL information and that the county has taken appropriate actions at each ECL. Provide training to appropriate staff.
Schedule of Corrective Actions: On the date this report was published, the State Schedule of Corrective Actions was not available.
4.1.2 28-03-5.a.1-A-02 Condition: Sirens were sounded prior to a Claiborne County, media press conference at 1150 without EOC coordination with any of the required parties for decision-making, including any elected officials at the EOC, and without discussion of information to be disseminated to the public.
Possible Cause: The County P1O notified the Director a press conference at 1150 and they needed to sound the sirens. The communicator was instructed to sound the sirens at 1143, prior to the press conference.
Coordination with the State for sounding of the sirens at 1 143 was not done. There was also no conversation pertaining to the content of information being presented to the media or public.
22
Reference:
Claiborne County Basic Plan Sections D and E; Annex C Section II-A page C-I., paragraph 2 Effect: The public would have heard the sirens without the benefit of any instructions for them to follow. This has the potential to cause public panic and overload the 91 1 system with calls from local citizens.
Recommendation: That, if present, elected officials should be included in all calls on the Alert Notification System (ANS), in addition to the operations manager of the EOC.
Sirens should never be sounded without prior coordination with required parties, i.e.
MEMA and Mississippi State Department of Health/DRH.
Schedule of Corrective Actions: The decision-makers present in the Claiborne County EOC at the time of the ANS phone message will hear the message along with the Director over a speaker phone. Sirens will not be sounded without prior coordination with required parties.
4.2 PRIOR ARCAS - RESOLVED 4.2.1 28-02-5.b.1-A-03
==
Description:==
The 1140 protective action ENMC decision (PAD) was to evacuate Protective Action Areas (PAAs) 1 and 5a and to shelter-in-place the remainder of the EPZ.
The information provided to the public was inconsistent with this decision. The 1 150 EAS message stated:
Government authorities have directed the following action for residents of the Claiborne County area; Evacuation in the following Protective Action Areas:
2 miles within Area 1 - Between Big Black River and Bayou Pierre west of Old Grand Gulf 23
Road 5 miles within Area 5a -
Between Bayou Pierre and Russum Westside Road, east to Widow's Creek.
Shelter in place the remaining 10 mile EPZ is sectors K, L and M.
The accompanying New Release included the information above and in the following sentence stated: "The remaining 10-mile EPZ is directed to shelter-in-place." The Mississippi spokesperson during the 1210 news conference stated that the shelter-in-place instruction was for the remaining EPZ not just sectors K, L and M. The reference to sectors K, L and M is not consistent with the information provided to the public in the 2002 GGNS Emergency Public Information Brochure, which only identifies the PAAs.
Corrective Action Demonstrated: All EAS messages, news releases, and media briefings addressed geographical areas as described in the 2003 GGNS Emergency Public Information Brochure, (i.e., as PAAs).
During the media briefings the State and County/Parish spokespersons correctly provided information to the media that was consistent with the PADs using the appropriate terminology. When referring to the PAAs, spokespersons also provided a description of the PAAs consistent with literature.
24
APPENDIX 1 ACRONYMS AND ABBREVIATIONS The following is a list of the acronyms and abbreviations, which may have been used in this report.
ARC American Red Cross ARCA Area Requiring Corrective Action CCCDD Claiborne County Civil Defense Director CFR Code of Federal Regulations DHS Department of Homeland Security DHHS Department of Health and Human Services DOC Department of Commerce DOE Department of Energy DOI Department of the Interior DOT Department of Transportation DPIO Deputy Public Information Officer DRH Division of Radiological Health EIC Emergency Information Center EAS Emergency Alert System ECL Emergency Classification Level EEM Exercise Evaluation Methodology EMA Emergency Management Agency EMS Emergency Medical Service ENMC Emergency News Media Center EOC Emergency Operations Center EOF Emergency Operations Facility EPA Environmental Protection Agency EPZ Emergency Planning Zone ER Emergency Room FAA Federal Aviation Administration FDA Food and Drug Administration FEMA Federal Emergency Management Agency FMT Field Monitoring Team FR Federal Register FRERP Federal Radiological Emergency Response Plan FRMAC Federal Radiological Monitoring and Assessment Center GE General Emergency GGNS Grand Gulf Nuclear Station 25
KI Potassium Iodide MEMA MREPP Mississippi Emergency Management Agency Mississippi Radiological Emergency Preparedness Plan NRC NUREG-0654 Nuclear Regulatory Commission NUREG-0654/FEMA-REP-1, Rev. 1, "Criteriafor Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, November 1980 OHL ORO Operation Hot Line Offsite Response Organization PAA PAD PAR Plo PPA Protective Action Area Protective Action Decision Protective Action Recommendation Public Information Officer Protective Action Area RAC REP RERP Regional Assistance Committee Radiological Emergency Preparedness Radiological Emergency Response Plan SAE SEOC Site Area Emergency State Emergency Operations Center TCP Traffic Control Point USDA U.S. Department of Agriculture 26
APPENDIX 2 EXERCISE EVALUATORS The following is a list of the personnel who evaluated the GGNS pilot exercise on September 17, 2003. The organization represented by each evaluator is indicated below.
DHS/FEMA - Department of Homeland Security Federal Emergency Management Agency ICF
- ICF Consulting, Incorporated NRC
- Nuclear Regulatory Commission Lawrence Robertson Co-RAC Chairman EVALUATION SITE EVALUATOR ORGANIZATION Chief Evaluator Eddie Hickman DHS/FEMA STATE OF MISSISSIPPI State Emergency Operations Center Eddie Hickman DHS/FEMA SEOC - PIO Radiological Health Radiological Field Monitoring Teams Dose Assessment/EOF Emergency News Media Bill Maier Bill Maier Bernie Hannah Harry Harrison Jim Hickey Robert Trojanowski Robert Perdue Bill Larrabee NRC NRC ICF ICF ICF NRC DHS/FEMA ICF CLAIBORNE COUNTY Emergency Operations Center Schools (A.W. Watson Elementary School)
EW Decon WARREN COUNTY Helen Wilgus Beth Massey Jane Young Jane Young DHS/FEMA DHS/FEMA DHS/FEMA DHS/FEMA 27
Medical Services Drill (MS-I)
(June 12, 2003 - Completed)
Eddie Hickman Larry Robertson.
DHS/FEMA DHS/FEMA COPIAH COUNTY Evacuee Monitoring & Registration (September 16, 2003 -1830 hours)
Temporary Care of Evacuees (September 16, 2003 -1900 hours)
Harry Harrison Jim Hickey ICF ICF 28
APPENDIX 3 EXERCISE CRITERIA AND EXTENT-OF-PLAY AGREEMENT This appendix lists the exercise criteria scheduled for demonstration in the Grand Gulf Nuclear Station exercise on September 17, 2003 and the extent-of-play agreement approved by FEMA Region IV.
A.
Exercise Criteria The specific radiological emergency preparedness criteria, which were to be demonstrated, have been consolidated with the extent-of-play for this event and are explained in subsection B.
B.
Extent-of-Play Agreement The Extent-of-Play agreement on the following pages was submitted by the State of Mississippi and was approved by FEMA Region IV.
29
Mississippi 2003 GGNS Exercise Extent-of Play Agreement OFFS1TE OBJECTIVE Unless otherwise noted, all demonstrations occur 9/17/03 during exercise time. Some activities will pre-stage personnel in order to conserve time.
- 1.
Emergency Operations Management Criterion 1.a.1:
Mobilization State EMA -
(State Emergency Management)
MSDHIDRH - (MS State Department of Health/Department Radiological Health)
Claiborne County State EOC and Claiborne County EOC staff will not be pre-staged, except for the MEMA Public Information Officer (PIO) and certain MSDH/DRH staff, i.e.,
Radiological Emergency Response Team Coordinator (RERTC) @ EOF and Radiological emergency Response Team (RERI). They will pre-stage due to travel times to location, as it will take too long for staff to arrive for the evaluation. Normal day-to-day staff will be present at evaluated locations.
Criterion 1.b.1:
Facilities State EMA MSDHEDRH Claiborne County Criterion 1.c.l:
Direction and Control State EMA MSDHIDRH Claiborne County Criterion 1.d.1:
Communications State EMA MSDEVDRH Claiborne County Criterion L.e.l:
Equipment and Supplies to Support Operations State EMA MSDH(DRH Claiborne County Copiah County (To be demonstrated 9/16/03 beginning at 6:30 pm.)
Warren County (Demonstrated out of sequence on 6/12/03) Complete.
Revised 7/2/03
Room accommodations will be set up beforehand to facilitate the exercise activities.
- 2.
Protective Action Decision Making Criterion 2.a.l:
Emergency Worker Exposure Control State EMA MSDHIDRH - (RERTs during accident assessment activities.)
Claiborne County Field Radiological Monitoring - Ambient Radiation Monitoring Criterion 2.b.1:
RAD Assessment & PAR & PADs based on Available Information MSDHMDRH - (Accident Assessment functions at GGNS EOF.)
DRH EOF staff will pro-stage in Claiborne County at the EOF @ 10:00 am.
Criterion 2.b.2:
RAD Assessment & PARs and PADs for the General Public State EMA MSDHIDRH Claibomne County Criterion 2.c.1:
Protective Action Decisions for Special Populations Claiborne County
- 3.
Protective Action Implementation Criterion 3.a.1:
Implementation of Emergency Worker Control MSDH/DRH - (With RERTs and at EOF)
Claiborne County Copiah County (To be demonstrated 9/16/03 beginning @ 6:30 pm.)
Warren County (Demonstrated out of sequence on 6/12/03). Complete RERTs and DRH EOF personnel will pre-stage in Claibome County @ 10:00 am. Staging area will be the Port Gibson area and the EOF respectively.
Criterion 3.b.l:
Implementation of 1I Decisions MSDH/DRH - (Field Team Personnel)
Claiborne County - (County Emergency Workers, i.e., school bus drivers)
Revised 712/03
Physical distribution of KI will be simulated Distribution logs and stock information will be available for review upon request Criterion 3.c.1:
Implementation of PADs for Special Populations Claiborne County Special populations alert list will be broken down by the kind of assistance needed along with available resources.
Criterion 3.c.2:
Implementation of PADs for Schools Claiborne County - A.W. Watson Elementary School & Claiborne County School Superintendent of Education:
Demonstration consists of interviews with school officials detailing their respective evacuation procedures. The Superintendent of Education was conducted out-of-sequence on 6/10/03. Complete Interview with A. W. Watson principal or representative will be conducted on 9/17/03 at 1:00 am.
Criterion 3.d.1:
Implementation of Traffic and Access Control State EMA - TCPs GE4, SAMl & SAE2 Demonstration was performed out of sequence on 6/10/03. Complete Claibome County - ACPs Al & A3 Demonstration with local law enforcement and city road maintenance department was performed out of sequence on 6/10/03. Complete Criterion 3.d.2:
Implementation of Evacuation and Traffic and Access Control State EMA - Demonstrated out of sequence on 6/10/03. Complete Claiborne County - Demonstrated out of sequence on 6/10/03. Complete
- 4.
Field Measurement and Analysis Criterion 4.a.1:
Plume Phase Field Measurements & Analysis Equipment MSDH/DRH - (With RERTs and at EOF)
Revised 7/2/03
RERTs and DRH EOF personnel will pre-stage in Claiborne County @ 10:00 am.
Staging area will be the Port Gibson area and the EOF respectively.
Criterion 4.a.2:
Plume Phase Field Measurements & Analysis management MSDH/DRH - (2 field teams)
Field Teams will be located in Claiborne County; the different locations will be announced.
Criterion 4.a.3:
Plume Phase Field Measurements & Analysis Procedures MSDH/DRH - (2 field teams)
Field Teams will be located in Claiborne County, the different locations will be announced.
- 5.
Emergency Notification & Public Information Criterion 5.a.1:
Activation of Prompt Alert and Notification State EMA Claiborne County Demonstration will consist of simulated siren activation. EAS messages will be developed at the SEOC and disseminated to risk county and EAS stations. There will be no broadcast of message by EAS stations. Actual message will be given to federal evaluator.
Criterion 5.a.3:
Activation of Prompt Alert & Notification Backup
.Alert/Notification Claiborne County Demonstration will consist of evaluator interviews with the Claiborne County EOC Personnel and review of applicable Back-up Alert/Notification Plans. Interviews will be conducted during the exercise.;
Criterion 5.b.1:
Emergency Info and Instructions for the Public and Media State EMA Claiborne County MEMA PIO will pre-stage in Claiborne County @ 9:30 am at the EMC.
Revised 7/2/03
Emergency Information - Rumor Control State EMA @ SEOC Claiborne County @ PGCC EOC Note that utility rumor control activities at ENMC are a utility operation addressing onsite plant issues. Current Statelocal news releases are used to address offsite questions that the utility rumor control may receive. The utility spokesperson will direct those State/local offsite questions which are unable to be answered from state/local news releases to the responsible party within the ENMC, ie., MEMA PIO, Claiborne County PIO. The correct response will be routed back to the utility area for response and/or will be disseminated via news release by the responding party. ITe correct response for offsite questions is the responsibility ofthe State and local organizations.
- 6.
Support OperationsAFacilities Criterion 6.a.l:
Monitoring and Decon of Evacuees and EWs and Registration of Evacuees Claiborne County - Pattison Fire Station (Pattison, MS)
This location will be filly operational to respond to cnt ed emergency workers reporting for monitong and decon. The use of expendable supplies will be simulated.
Only one emergency worker monitor will be filly dressed out. EW Decon station supplies will be available for evaluator inspection upon request. Decontamination of one EW will be simulated - no water will actually be used.
Warren County- (Demonstrated out of sequence on 6/12103) Complete Copiah County - (Demonstration out of sequence ( 6:30 pm on 9/16/03)
The use of some expendable supplies will be simulated, ie., floor covering, multiple layers of protective clothing (rubber gloves, booties, etc.) and barricade tape. Evaluators will be advised of simulated items. All resources will be available for evaluator viewing upon request Two cars with six people will be monitored. Two people will be contaminated and dtamnated (1 femrale/l male). The use of shower facilities will be simulated. Vehicles will be parked in a secure area for monitoring and decontamination, as per procedures. Only one emergency worker will be fully dressed out to demonstrate protective clothing. (Affected County is responsible for supplying people and vehicles for exercise play.)
Criterion 6.b.1:
Monitoring and Decon of Emergency Worker Equipment Claiborne County - Pattison Fire Station (Pattison, MS)
This location will be fully operational to respond to contaminated emergency workers reporting for monitoring and decon. The use of expendable supplies will be simulated.
Revised 7/2/03
Only one emergency worker monitor will be filly dressed out. EW Decon station supplies will be available for evaluator inspection upon request Decontamination of one EW will be simulated - no water will actually be used. Decontamination of the vehicle will be demonstrated by actually using water and setting up an EW Monitoring and Decontamination station.
Criterion 6.c1.:
Temporary Care of Evacuees Warren County - (Demonstrated out of sequence on 6112/03) Complete Copiah County- (Demonstration out of sequence @ 7:00 pm on 9/16/03)
Demonstration will consist of registering those individuals that pass through the Reception Center by completing Red Cross Shelter Regisration Forms. Sic Evacuees will be registered. All remaining shelter facility capabilities will be simulated. Lsting of shelter staff and resources will be available upon request Any remaining exercise information will be provided during shelter managers interviews. Walk through of shelter facility building will be provided if needed, using a diagram showing the location of all essential ARC functions.
Criterion 6.d.1:
Transport and Treatment of Contaminated Injured Individuals Demonstrated out of sequence during MS-1 Drill on 6/12/03. Complete Revised 7/2/03
APPENDIX 4 EXERCISE SCENARIO This appendix contains a summary of the simulated sequence of events (exercise scenario) which was used as the basic for involving emergency response actions by OROs in the GGNS exercise on September 17, 2003. This exercise scenario was submitted by the State of Mississippi and approved by FEMA Region IV.
30
GRAND GULF NUCLEAR STATION 2003 GRADED EXERCISE 7.0 EXERCISE SCENARIO INITIAL CONDITIONS The plant is operating at 100% power 12 months into the current 18 month operating cycle. The weather is cool with generally overcast skies and moderate 10 to 20 mph winds.
A Div. II workweek is in progress.
CRD Pump 'B' is tagged out for PM's.
Water was discovered in the last oil sample and mechanical maintenance is leak checking the oil cooler and replacing the oil.
A tag out was hung on mid night shift to allow I&C to work in the back of panel P870 section 7A. The tag out inops several sections of annunicators on the P870, P807, P845, P844, P680 and P854 panels.
Work should be complete and the tag out should be cleared by 0930 today.
Compensatory Action Plan is in place.
Maintenance on "')" Demin is in progress. Limit switches on IN22F055D are being returned to service after replacement.
Turbine Building rollup door is open.
Radwaste Building rollup door is open.
Auxiliary Building rollup door is shut.
Current Homeland Security Advisory Threat Level is: Yellow (Significant Risk of Terrorist Attacks)
- Severe = Red
- High = Orange
- Elevated = Yellow
- Guarded = Blue
- Low = Green 7-1
GRAND GULF NUCLEAR STATION 2003 GRADED EXERCISE NARRATIVE
SUMMARY
The DRILL begins at approximately 0800.
At 0805 unidentified leakage at approximately 8 gpm causes alarm IH13P60122AF1 "Drywell Sump Discharge Rate High" to initiate. Leakage is due to a crack in the "B" feedwater line in the Drywell. Leakage is from the downstream weld on the valve body of N21FO11B. Drywell leakage will be slowly increasing until LOCA occurs.
0805-0820 an UNUSUAL EVENT should be declared on EAL 2.1, "Exceeding Primary Coolant System Leak Rate >5 gpm in Modes 1, 2, or 3'. The Shift Manager should turn over the control and command function to the Shift Supervisor and announce that he is the Emergency Director.
At 0915 the "A" APRM will fail upscale causing a rod block and a reactor 1/2h scram. The annunicators for control room panels P680, P601 and P870 will not be operable. The operators should notice the upscale APRM, absence of the associated alarms, the flashing power loss alarms (no audible alann), and respond to the reactor 'A scram condition.
The control room should investigate the annunciator problem and determine that a complete loss of annunciators on the P680, P870 and P601 panels has occurred.
0915-0930 an ALERT should be declared on EAL 17.2, "Loss Of All Annunciators".
By approximately 1000 to 1015 (45 minutes after Alert declared) the TSC, EOF, and the OSC must be manned and control of the emergency transferred to the TSC or the EOF.
When calculating the actual amount of time taken for the TSC to become operational, consideration should be given to the fact that an average of 6 minutes is required for the Emergency Director to travel from the Admin Building to the Simulator and back to the Admin Building. This does not include turnover time.
Under actual emergency conditions, the Emergency Director would travel directly from the admin building to the TSC and not detour to the Simulator. Therefore, during drills or exercises, 6 minutes should be subtracted from the total time taken for the TSC to declare itself operational.
At 1020, the problem with the control room annunicators is corrected and the annunicators are returned to service.
At 1025 a malfunction in the condensate pump min flow circuit causes a trip of all of the running condensate pumps, condensate booster pumps and reactor feed pumps. "P171 Panel Trouble" alarm comes in on the P680 panel. All six of the min flow indicating lights come on and stay on until the flow card is replaced. Condensate can not be restored until the card is replaced.
7-2 CONFIDENTIAL
GRAND GULF NUCLEAR STATION 2003 GRADED EXERCISE When the reactor scrams, the "B" feedwater line ruptures in the Drywell. Rupture is such that HPCS injection can maintain reactor level greater than -167". Condensate/Feedwater injection through the 'B' feedwater line and RCIC should be secured.
At 1030 Div II Bus 16AB trips and lockouts when a fault occurs in breaker 152-1606, RHR 'B' pump supply breaker. The fault occurs due to the misalignment of the breaker stabs to the bus bar connection. Damage to the bus bars has occurred and the 16 Bus is not recoverable..
The TSC will lose power to the hallway lights, one half of the TSC work area lights, the Communicator cubicle lights, Communicator computer, wireless PA system, Engineering Intercom, Engineering computer, and the HP instruments in the supply cabinet.
Inverter 1Y92 will supply power to thei Dose Calculator Computer, the radio, SPDS computer, PDS Computer located on the cabinet in the Engineering Area, and the TSC communication system. Inverter 1Y92 (supplies power to TSC loads) will lose its alternate power supply and will be carried on the I IDL battery bank. This DC supply should last approximately 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
Both battery chargers for 1 DL battery will be lost due to being fed from Div II AC power supplies.
HPCS, CRD A, and SLC A are the only operable high pressure injection systems. LPCS and RHR 'A' are available for injection if reactor'depressiarizaiion occurs. Level is maintained greater than -167".
At approximately 1037-1038, or when the MSIV's close on loss of instrument air, a steam line break occurs on the "D" Main steam line in the Auxiliary Building Steam Tunnel, upstream of the B21-F028D. The inboard MSWV B21-F022D fails to close completely and the leak can not be isolated. Hi Main Steam Tunnel temperature and Hi Main Steam Tunnel Delta T alarms occur.
Fire Alarm Zones FZ0243 and FZ0244 come in, indicating that the Aux Steam Tunnel blowout panels have lifted. The shift should verify that the MSlV's, MSL drain valves and RWCU Systems isolate as required.
At 1037-1052 a SITE AREA EMERGENCY should be declared on EAL 4.3, "Main Steam Line Break Outside Of Containment Which Can Not Be Isolated".- Actual time will depend on the time of the MSIV's drifting shut on loss of air.
A SITE EVACUATION should be ordered and personnel accountability initiated.
Personnel accountability should be complete before about 1122 (within 30 minutes from declaration of SAE).
Reactor water level should be maintained above TAF utilizing HPCS.
7-3 CONFIDENTIAL
GRAND GULF NUCLEAR STATION 2003 GRADED EXERCISE At 1110 ESF Bus 15AA trips and a bus lock out occurs due to a bus ground overcurrent. An insulator failure resulted in a bus ground causing the lockout. The insulator and a small section of bus must be replaced before 15AA can be restored.
Announcement should be made that personnel accountability is complete and personnel may enter the protected area.
At 1115 the HPCS pump trips due to a fault in the motor windings and the OVERCURRENT TRIP CIRCUIT is actuated for breaker 152-1702. HPCS system is not recoverable.
After the HIPCS puMP trips, a GENERAL EMERGENCY may be declared based on discretionary EAL 18.3, "Conditions Exist That Make The Release Of Large Amounts Of Radioactivity In A Short Time Period Possible'. No feed sources will be available to maintain reactor water level above -167".
1125 reactor water level drops to below -167" and cannot be recovered. Reactor water level continues to go down.
1125-1140 GENERAL EMERGENCY should be declared on EAL 3.4 '(Loss Of 2 Out Of 3 Fission Product Barriers With A Potential Loss Of The Third" when reactor water level goes below -167" (if a discretionary GE was not previously declared).
Initial wind direction will be into Sectors Q, R and A. These sectors include the EOF and OSC. Activation of the Backup EOF and OSC will not be demonstrated. Radiological conditions are provided that account for EOF shielding factors. The plume will be simulated to rise over the OSC and touchdown outside the Protected Area due to building wake and turbulence affects. If the participants discuss relocating to the backup facilities, Controllers will interject that the backup facilities will not be activated.
1135 Reactor water level goes below -192" and can not be restored.
Emergency depressurization is required.
Severe Accident Procedures are entered.
Radiological Assessment changes to Core Damage Mix.
1140 damage to the fuel cladding begins, indications of an offsite release are seen.
1145 overheating core damage begins and offsite releases increase dramatically.
In the event the Radiological Assessment Staff calculates conditions that would necessitate issuing PARs outside of the 10 mile EPZ, PAR development and PAR notification opportunities for these conditions will not contribute to the NRC Performance Indicators.
7-4 CONFIDENTIAL
- GRAND GULF NUCLEAR STATION 20003 GRADED EXERCISE Installation of attachment 26 for fire water injection should be requested and lineup commenced 1230-1300 the wind shifts from 150 degrees (sectors Q,R,A) to 225 degrees (sectors B,C,D).
At 1300 the bus bar for bus 15AA is replaced, bus 15AA red tag can be cleared and power can be restored to the bus.
At 1310, the flow card in the condensate pump min flow circuit is replaced and condensate pumps are available for injection.
At 1320 the red tag for bus 15AA is cleared. Div I ECCS systems are available for injection.
At 1325 the injection systems which have been restored will begin to raise reactor water level and level will come on scale.
Reactor pressure will gradually fall to zero psig and the release will cease at 1345.
By 1345 facilities should be into discussions of a re-entry and recovery plan.
At 1400 the drill will be terminated.
7-5 CONFIDENTIAL
GRAND GULF NUCLEAR STATION 2003 GRADED EXERCISE 0800 0805 0805-0820 0915 0915-0930 1000 1000-1015 1020 1025 1030 00:00 00:05 00:05-00:20 01:15 01:15-01:30 02:00 02:00-02:15 02:20 02:25 02 30 Drll begins.
H13-P680-8-A1-D7 "Drywell Floor Drain Sump Temperature Hi" due to unidentified leakage >5 gpm.
UNUSUAL EVENT on EAL 2.1, Exceeding Primary Coolant System Leak Rate >5 gpm in Modes 1, 2, or 3.
Pt Opportunity. Record time of alarm, time of declaration, and time of notification.
"A" APRM fails upscale, alarms do not annunicate.
Loss of all annunicators on IH13-P680,P870, and P601. Breakers 72-1 1E68 and 72-1 1E74 trip.
ALERT on EAL 17.2, Loss Of All Annunciators.
PI Opportunity. Record time APRM fails upscale, time of declaration, and time of notification.
72-1IE68 and72-1 1E74 reset and closed, annunication partially restored.
TSCOSC,EOF operational.
72-1 1D5 1 tag cleared, breaker closed, annunication restored.
Condensate pump min flow failure.
Reactor scram.
Feedwater line break in D/W.
16AB Bus lockout due to bus bar damage from 152-1606 breaker fault.
7-6 CONFIDENTIAL
GRAND GULF NUCLEAR STATION 2003 GRADED EXERCISE The TSC will lose power to the hallway lights, the computer terminal on the engineers' desk, and the HP instruments in the supply cabinet. One half of the lights in the TSC work area will be lost in addition to the hallway lights.
Inverter IY92 will supply power to the Dose Calculator Computer, the radio, PDS Computer located on the cabinet in the Engineering Area, and the TSC communication system. Inverter 1Y92 (supplies power to TSC loads) will lose its alternate power supply and will be carried on the 1 DL battery bank. This DC supply should last approximately 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. Both battery chargers for 11DL battery will be lost due to being feed from Div I AC power supplies.
1037-1038 02:37-02:38
'D' main steam line break in Aux Bldg Steam Tunnel.
B21-F022D fails to isolate.
Hi Main Steam Tunnel temperature and HI Main Steam Tunnel Delta T alarms.
Fire Alarm Zones FZ0243 and FZ0244 on Aux Steam Tunnel Blowout Shafts.
1037-1052 02:37-02;52 SITE AREA EMERGENCY on EAL 4.3 "Main steam line break outside of containment which can not be isolated".
SITE EVACUATION and personnel accountability should be ordered.
PI Opportunity. Record time of break, time of declaration, and time of notification.
1107-1122 03:07-03:22 Personnel accountability complete (30 min. from declaration of SAE).
Announce personnel accountability is complete.
1110 03:10 15AA bus lockout.
7-7 CONFIDENTIAL
GRAND GULF NUCLEAR STATION 2003 GRADED EXERCISE 1115 03:15 HPCS pump trip, no high pressure systems available for reactor water makeup.
After the HPCS pump trips, a GENERAL EMERGENCY may be declared based on discretionary EAL 18.3 'Conditions exist that make the release of large amounts of radioactivity in a short time period possible".
If Discretionary GE declared, record indications available to the participant that would support the determination of GE.
PI Opportunity. Record time of HPCS pump trip, time of declaration, vessel level and trend, and notification time. Verify Steam Cycle Mix used for Dose Projections. Verify PARs include appropriate sectors and distances for the Dose Projection calculations.
1125 03:25 Reactor water level drops below -167".
1125-1140
-03:25-03:40 GENERAL EMERGENCY declared due to "Loss of 2 of 3 fission product barriers with a potential loss of the third barrier".
PI Opportunity. Record time of HPCS pump trip, time of declaration, vessel level and trend, and notification time. Verify Steam Cycle Mix used for Dose Projections. Verify PARs include appropriate sectors and distances for the Dose Projection calculations.
1135 03:35 Reactor water level drops to below -192".
Emergency Depressurization required.
Severe Accident Procedures entered.
Radiological Assessment changes to Core Damage Mix.
7-8 CONFIDENTIAL
GRAND GULF NUCLEAR STATION 2003 GRADED EXERCISE 1140 03:40 Clad damage begins.
Offsite release begins.
1145 03:45 Overheating core damage begins.
Offsite release rates increase dramatically.
Activation of the Backup EOF and OSC will not be demonstrated. Initial wind direction will be into Sectors Q,R, and A. These sectors include the EOF and OSC. Activation of the Backup EOF and OSC will not be demonstrated. Radiological conditions are provided that account for EOF shielding factors. The plume will be simulated to rise over the OSC and touchdown outside the Protected Area due to building wake and turbulence affects. If the participants discuss relocating to the backup facilities, Controllers will interject that the backup facilities will not be activated.
1230-1300 04:30-05:00 Wind shifts from Sectors QRA to Sectors BCD.
PI Opportunity. Record time that each new sector becomes affected. Record time that each new PAR developed (REM initialing ENF), and time of notification.
Several opportunities may exist, depending on the speed of the shift and the timing of each new sector becoming affected.
1300 05:00 15AA bus bar repaired, red tag being cleared.
1310 05:10 Flow card for condensate min flow circuit replaced, condensate available for injection.
1320 05:20 Red tag on l5AA cleared, 15AA energized, Div I ECCS available for injection.
1325 05:25 Reactor water level increasing, level on scale.
7-9 CONFIDENTIAL
1345 1345 1400 GRAND GULF NUCLEAR STATION 2003 GRADED EXERCISE 05:45 Reactor pressure reduced to zero psig.
Release terminated.
05:45 Re-entry and recovery plan development begins.
06:00 Drill terminated.
7-10 CONFIDENTIAL