Text
Tennessee Valley Authority, Post Office Box 2000, Decatur, Alabama 35609-2000 March 4, 2004 10 CFR 50.36a(a) (2) 10 CFR 50, Appendix I,Section IV.B.1 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop:
OWFN, P1-35 Washington, D.C. 20555-0001 Gentlemen:
In the Matter of
)
Docket Nos. 50-259 Tennessee Valley Authority
)
50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN)
UNITS 1, 2,
AND 3 -
LIQUID RELEASE UPDATE TO THE 2002 ANNUAL RADIOACTIVE EFFLUENT RELEASE (ARER) REPORT; This letter provides an update to the 2002 annual radioactive effluent release (ARER) -report including three corrected pages in Enclosure 1 and four corrected pages in. The original-ARER was submitted to the NRC on April 30, 2003, and subsequently updated on August 25, 2003, to correct some erroneous table values.
This liquid release update also-covers the period from January 1, 2002, through December 31, 2002, and supersedes both previous ARER reports.
An abnormal liquid release from the Unit 3 station sump in the Turbine Building occurred on August-14, 2003.
During the investigation of this event, -it was' determined that traces of Fluorine-18 existed in.spectra dating back to September 2, 2002.
Traces of tritium were found in the composite of batch releases made--in August 2003. The level of tritium found in the composite-was assumed to be present in all samples indicating Fluorine-18. The following changes were made-to-indicate the abnormal release:
(1) In Table 7 and Table.8 on pages E1-14 and El-15, the dose columns were revised to indicate dose from the abnormal release. Previous values were recorded as zero mrem.
Consequently, this release also affected the population dose values shown on these pages.
The Populations doses were previously recorded as zero man-rem.
hrted n Icycd pat
U.S. Nuclear Regulatory Commission Page 2 March 4, 2004 Since there was no liquid release documented in the original ARER there was no riverflow recorded.
However, as a result of this identified liquid release, the average riverflow past BFN is now documented.
(2) In Table 9, on page E1-16, doses were added for the third and fourth quarter to the Total Body or any Organ Dose (except thyroid) and to the Thyroid Dose. The third and fourth quarter totals and the cumulative total doses were not affected by this change since the dose values for liquid were small compared to the previously reported airborne doses.
(3) On page E3-5, in item IV.C, one liquid release with the total activity release value was added where the previous values were documented as "None".
(4) On page E3-6, in item A.1, the Fluorine-18 release value was added to the total release value for the third and fourth quarters.
(5) On page E3-6, in item B.1, the tritium value was added to the total release value for the third and fourth quarters.
(6) On page E3-7, Others, item 1, a Fluorine-18 value was added to the third and fourth quarters.
(7) On page E3-18, paragraph 2 was revised to provide an explanation of the abnormal liquid release. The previous paragraph 2 indicated there were no abnormal liquid releases.
An extent of the condition review of this liquid release did not identify any additional abnormal liquid releases.
U.S. Nuclear Regulatory Commission Page 3 March 4, 2004 If you have any questions concerning this liquid release update to the 2002 ARER report, please contact me at (256) 729-2636.
S nch r 1 Manager of e L censing and Indu try Aff irs Enclosures cc(Enclosure (Via NRC Electronic Distribution)
Ms. Eva A. Brown, Project Manager U.S. Nuclear Regulatory Commission (MS 08G9)
One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852-2739 Mr. Kahtan N. Jabbour, Senior Project Manager U.S. Nuclear Regulatory Commission (MS 08G9)
One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852-2739 Mr. Stephen J. Cahill, Branch Chief U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth Street, S. W., Suite 23T85 Atlanta, Georgia 030303-8931 NRC Resident Inspector Browns Ferry Nuclear Plant 10833 Shaw Road Athens, Alabama 35611-6970 Mr. Ronald Sanacore American Nuclear Insurers Town Center, Suite 300S 29 South Main Street West Hartford, Connecticut 06107-2430 U. S. Nuclear Regulatory Commission Attn:
REIRS Project Manager Office of Nuclear Regulatory Research Washington, D.C. 20555-0001
ENCLOSURE I TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)
UNITS 1, 2, AND 3 RADIOLOGICAL IMPACT ASSESSMENT REPORT JANUARY THROUGH DECEMBER 2002 TABLE OF CONTENTS
- 1.
Introduction El-2 II.
Dose Limits EI-2 I11.
Dose Calculations El-3 IV.
Doses from Airborne Effluents EI-3 V.
Doses from Liquid Effluents El-5 VI.
Population Doses El-5 V1I.
Offsite Direct Radiation Dose EI-6 Vill.
Dose to a Member of-the Public Inside the Site Boundarv EI-6 Lx.
Total Dose El-7 El-i
I-TABLE OF CONTENTS (Continued)
Listing of Tables Table I - Doses from Airborne Effuents - First Quarter El-8 Table 2 - Doses from Airborne Effluents - Second Quarter El-9 Table 3 - Doses from Airborne Effluents - Third Quarter El-1 Table 3 - Doses from Airborne Effluents - Fourth Quarter El-1l Table 5 - Doses from Liquid Effluents - First Quarter El-12 Table 6 - Doses from Liquid Effluents - Second Quarter EI-13 Table 7 - Doses from Liquid Effluents - Third Quarter EI-13 Table 8 - Doses from Liquid Effluents - Fourth Quarter El-15 Table 9 -Total Dose from Fuel Cycle El-16 Table 10 - Joint Frequency Distribution in Percent for Ground E2 Level Releases - First Quarter E2-9 Table 11 - Joint Frequency Distribution in Percent for Ground E2 Level Releases - Second Quarter E2-17 Table 12 -Joint Frequency Distribution in Percent for Ground E2 Level Releases - Third Quarter E2-25 Table 13 - Joint Frequency Distribution in Percent for Ground E2 Level Releases - Fourth Quarter E2-33 Table 14 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Ground Level Portion) -First Quarter E24 1 Table 15 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Ground Level Portion) - Second Quarter E2-49 Table 16 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Ground Level Portion) - Third Quarter E2-57 Table 17 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Ground Level Portion) - Fourth Quarter E2-65 Table 18 -Joint Frequency Distribution in Percent for Split Level E2 Releases (Elevated Level Portion) - First Quarter E2-73 El-la
TABLE OF CON'TENTS (Continued)
Listing of Tables Table 19 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Elevated Level Portion) - Second Quarter E2-81 Table 20 - Joint Frequency Distribution in P- -'ent for Split Level E2 Releases (Elevated Level Portion) - nird Quarter E2-89 Table 21 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Elevated Level Portion) - Fourth Quarter E2-97 Table 22 - Joint Frequency Distribution in Percent for Elevated E2 Releases - First Quarter E2-105 Table 23 - Joint Frequency Distribution in Percent for Elevated E2-106-Releases - Second Quarter E2-113 Table 24 - Joint Frequency Distribution in Percent for Elevated E2-114-Releases - Third Quarter E2-121 Table 25 - Joint Frequency Distribution in Percent for Elevated E2-122-Releases - Fourth Quarter E2-129 El-lb
/
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 I. INTRODUCTION Potential doses to the "maximum exposed individual" and the population around Browns Ferry are calculated for each quarter as required in Section 5.2 of the Offsite Dose Calculation Manual (ODCM). The methodology for determining plant releases for the reporting period used to estimate dose is specified in Sections 6 and 7 of the ODCM. Dispersion of radioactive effluents in the environment is estimated using meteorological data and river flow measured during the period. In this report, the doses resulting from releases are described and compared to limits established for Browns Ferry.
II. DOSE LIMITS The ODCM specifies limits for the release of radioactive effluents, as well as limits for doses to the general public from the release of radioactive effluents. These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.
The air dose limits in areas at and beyond the Site Boundary due to noble gases released in gaseous effluents per unit are:
< 5 mrad per quarter and
- 10 mrad per year for gamma radiation.
- and -
< 10 mrad per quarter and
< 20 mrad per year for beta radiation.
The dose limits to a Member of the Public in an unrestricted area from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives > 8 days released in gaseous effluents for each unit are:
< 7.5 mrem per quarter and 15 mrem per year to any organ.
The dose or dose commitment to a Member of the Public from radioactive material in liquid effluents released to unrestricted areas are:
< 1.5 mrem per quarter and
< 3 mrem per year to the total body,
-and -
< 5 mrem per quarter and
-510 mrem per year to any organ.
The limit for the total effective dose equivalent to an individual Member of the Public inside the site boundary is:
100 mrem per year.
The EPA limits for total dose to any Member of the Public in the vicinity of a nuclear power plant, established in the Environmental Dose Standard of 40 CFR 190, are:
< 25 mrem per year to the whole body, 5 75 mrem per year to the thyroid,
-and -
< 25 mrem per year to any other organ.
El-2
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Meteoroloical Data Meteorological variables at BFN are measured continuously. Measurements collected include wind speed, wind direction, and temperature at heights of 10, 45, and 91 meters above the ground. Quarterly JFDs are calculated for each release point using the appropriate levels of meteorological data. A quarterly 3FD gives the percentage of the time that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine wind speed ranges. Calms are distributed by direction in proportion to the distribution of noncalm wind directions less than 1.6 m/s (3.5 mph). Stability classes are determined from the vertical temperature difference between two measurement levels.
The generally open terrain around BFN does not cause any significant effects on the transport and dispersion of gaseous effluents from the plant. Within 30 kilometers of BFN, the terrain is mostly gently rolling hills (30-60 meters). Between 30 and 80 kilometers the hills become larger to the north and south, and mountainous to the east and northeast. The Tennessee River/Wheeler Lake may have a minor effect on transport and dispersion in the immediate vicinity of BFN during periods of winds with a southerly component, overcast skies, and relatively high wind speeds. Also, the lower layer (1045 meters) stability class tends to be more stable. However, during this infrequent condition, dose estimates will be conservative.
External Exposure Dose Dose calculated for maximum external air dose (gamma-air and beta-air ) are made for points at and beyond the unrestricted area boundary as described in the BFN ODCM. The highest of these doses is then selected.
Submersion Dose External doses to the skin and total body, due to submersion in a cloud of noble gases, are calculated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.
Organ Dose Dose to an organ due to releases of airborne effluents are estimated for the inhalation, ground
- contamination, and ingestion pathways. The ingestion pathway is further divided into three possible contributing pathways: ingestion of cow/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor.
For the ingestion dose, however, only those pathways that exist for each receptor are considered in the sum, i.e., milk ingestion doses are included only for locations where milk was consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden was identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contamination, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.
The maximum organ dose, thyroid dose, and total body dose from airborne effluents are presented in Tables 1, 2, 3, and 4.
E1-4
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 V. DOSES FROM lIOUTD EFFLUENTS For liquid effluents, the public can be exposed to radiation from three sources: the ingestion of water from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactive material deposited on the river shoreline sediment (recreation).
The concentration of radionuclides in the Tennessee River are calculated by a computer model which uses measured hydraulic data downstream of BFN. Parameters used to determine the doses are based on guidance given by the NRC (in Regulatory Guides 1.109) for maximum ingestion rates, exposure times, etc.
Wherever possible, parameters used in the dose calculation are site specific. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the BFN ODCM.
Liquid Release Points and River Data Radionuclide concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. When necessary, liquid releases from BFN, located at Tennessee River Mile 294, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-fifth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at the first downstream dam (Wheeler Dam), at Tennessee River Mile 283.0.
Doses are calculated for locations within a 50 mile radius downstream of the plant site. The maximum potential recreation dose is calculated for a location immediately downstream from the plant's release point.
The maximum exposed individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught anywhere between the plant and the first downstream dam. The maximum exposed individual dose from drinking water is assumed to be that calculated at the nearest downstream public water supply [West Morgan - East Lawrence (WMEL)]. This could be interpreted as indicating that the maximum exposed individual, as assumed for liquid releases from Browns Ferry, is an individual who obtains all of his drinking water at WMEL, consumes fish caught from the Tennessee River between BFN and Wheeler Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just downstream of the plant's release point. Doses calculated for the maximum exposed individual due to liquid effluents for, each quarter in the period are presented in Tables 5, 6, 7, and 8, along with the average river flows past the plant site for the periods.
VI. POPULATION DOSES Population doses due to airborne effluents are calculated for an estimated 627,000 persons living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distribution. Ingestion population doses are calculated assuming that each individual consumed milk, vegetables, and meat produced within the sector in which the individual resides.
Population doses due to liquid effluents are calculated for the entire downstream Tennessee River population. Water ingestion population doses are calculated using actual population figures for downstream public water supplies. Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population. Recreation population doses are calculated using historical recreational data on the number of shoreline visits at downstream locations.
Population doses calculated for airborne and liquid effluents are presented in Tables 1, 2, 3, 4, 5, 6, 7, and 8.
El-5
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 VII. OFFSITE DIRECT RADIATION DOSE External gamma radiation levels were measured by thermoluminescent dosimeters (TLDs) deployed around BFN as part of the offsite Radiological Environmental Monitoring Program (REMP). The quarterly gamma radiation levels determined from these TLDs during this reporting period averaged approximately 16.0 mremlquarter at onsite (at or near the site boundary) stations and approximately 14.3 mrem/quarter at offsite stations or approximately 1.7 mrem/quarter higher onsite than at offsite stations. This difference is consistent with levels measured for pre-operation and construction phases of TVA nuclear plants where the average radiation levels onsite were generally 2-6 mremlquarter higher than the levels offsite. This may be attributable to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plants, or other undetermined influences. Fluctuations in natural background dose rates and in TLD readings tend to mask any small increments which may be due to plant operations. Thus, there was no identifiable increase in dose rate levels attributable to direct radiation from plant equipment and/or gaseous effluents.
VIII. DOSE TO A MAIEMBER OF THE PUBLIC INSIDE THE SITE BOUNDARY Pursuant to ODCM section 7.7.5, a review was performed to determine the highest dose to a member of the public in the site boundary. This review assumed that onsite TVA employees engaged in work activities not associated with nuclear power electric generation were considered as members of the public. The dose to a member of the public consists of the sum of dose commitments from effluent releases as well as any direct radiation dose. The effluent dose commitment is negligible compared to the direct radiation dose.
The direct radiation dose was determined from area TLDs located onsite. It consisted of gamma dose from the plume, ground contamination and from equipment sources (i.e., tanks, turbine shine, radioactive material storage areas, etc.). The highest direct radiation dose accounting for background and occupancy was 5.0 mrem during 2002.
The total annual dose commitment to the member of the public for 2002 is 5.0 mrem; the direct radiation dose while in the site boundary. It can be concluded that the dose limit for a member of the public inside the site boundary as specified in 10 CFR 20.1301 was not exceeded.
El-6
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 IX. TOTAL DOSE To determine compliance with 40 CFR 190, annual total dose contributions to the maximum exposed individual from BFN radioactive effluents and all other nearby uranium fuel cycle sources are considered.
The annual dose to any organ other than thyroid for the maximum exposed individual is conservatively calculated by summing the following doses: the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for total body or any organ dose (other than thyroid) to determine compliance.
The annual thyroid dose to the maximum exposed individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for thyroid dose to determine compliance.
Total dose from the fuel cycle is presented in Table 9.
E1-7
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table I Doses from Airborne Effluents First Quarter Indi-idual Doses Pathway Dose Quarterly Limit Percent of Limit Location External llll_
l Gamma Air 5.8E-06 mrad 5 mrad
< 1 %
S/6800 meters Beta Air 9.3E-06 mrad 10 mrad
< 1 %
S/6800 meters Submersion Total Body 2.7E-04 mrem NA NA N/2000 meters Skin 3.2E-04 mrem NA NA N/2000 meters Organ Doses Child/Bone 1.4E-02 mrem 7.5 mrem
< 1 %
NNW/1770 meters Child/Thyroid 4.1E-02 mrem 7.5 mrem
< 1 %
NNW/1770 meters Child/Total Body 1.2E-02 mrem 7.5 mrem
<1 %
NNW/1770 meters Population Doses Total Body Dose 1.9E-02 man-rem Maximum Organ Dose (organ) 8.1E-02 man-rem (thyroid)
Population doses can be compared to the natural background dose for the entire SO-mile population of about 70,044 man-remn/year (based on 90 mreminyrfor natural background).
E1-8
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 2 Doses from Airborne EMuents Second Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 1.UE-05 mrad 5 mrad
<1 %
WNW/5500 meters Beta Air 3.0E-05 mrad 10 mrad
< 1 %
WNW/5500 meters Submersion Total Body 9.4E-04 mrem NA NA NNW/1639 meters Skin 1.1E-03 mrem NA NA NNW/1639 meters Organ Doses Child/Liver 8.3E-03 mrem 7.5 mrem
< 1 %
NNW/1770 meters Child/Thyroid 2.4E-01 mrem 7.5 mrem 3 %
NNW/1770 meters Child /Total Body 4.6E-03 mrem 7.5 mrem
< 1 %
NNW/1770 meters Population Doses Total Body Dose 1.3E-02 man-rem Maximum Organ Dose (organ) 7.7E-01 man-rem (thyroid)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 inremlyrfor natural background).
El-9
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 3 Doses from Airborne Effluents Third Quarter Individual Doses Pathway Dose Quarterly Ul tl Percent of Limit Location External Gamma Air 9.1E-04 mrad 5 mrad
< 1 %
NNW15600 meters Beta Air 1.2E-03 mrad 10 mrad
< 1 %
NNW/5600 meters Submersion Total Body 1.6E-03 mrem NA NA NNW/1639 meters Skin 1.9E-03 mrem NA NA NNW/1639 meters Organ Doses I,_
Child/Bone 1.6E-02 mrem 7.5 mrem
< 1 %
NNW/1770 meters Childl hyroid 1.9E-02 mrem 7.5 mrem
< 1 %
NNW/1770 meters Adult/Total Body 6.1E-03 mrem 7.5 mrem
< 1 %
NNW/1770 meters Population Doses Total Body Dose 3.2E-02 man-rem Maximum Organ Dose (organ) 7.9E-02 man-rem (thyroid)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mremnyr for natural background).
El-10
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 4 Doses from Airborne Effluents Fourth Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External
__7_1 Gamma Air 5.3E-04 mrad 5 mrad
<1 %
SSE/7800 meters Beta Air 5.7E-04 mrad 10 mrad
<1 %
SSE/7800 meters Submersion Total Body 2.8E-03 mrem NA NA NNW11639 meters Skin 3.3E-03 mrem NA NA NNW/1639 meters Organ Doses Child/ Bone 4.4E-02 mrem 7.5 mrem
<1 %
NNW/1770 meters Childfrhyroid 6.5E-01 mrem 7.5 mrem 8.7 %
NNW/1770 meters Child /Total Body 2.1E-02 mrem 7.5 mrem
<1 %
NNW/1770 meters Population Dooses Total Body Dose 8.2E-02 man-rem Maximum Organ Dose (organ) 2.1E+00 man-rem (thyroid)
Population doses can be compared to the natural background dosefor the entire SO-mile population of about 70,044 man-remn/year (based on 90 mnreinlyrfor natural background).
El-11
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 5 Doses from Liquid Effluents First Quarter*
Individual Doses (mrem)
Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0
Recreation 0 ° Water Ingestion 0
Total 0
1.5 mrem 0 %
Liver Fish Ingestion 0
Recreation 0
Water Ingestion 0
Total 0
5 mrem 0 %
Thyroid Fish Ingestion 0
Recreation 0
l Water Ingestion 0
Total 0
5 mrem 0 %
- No liquid releases were made this quarter.
Average Riverflow past BFN (cubic feet per second): No Release Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)
Population doses can be compared to the natural background dose for the entire SO-mile population of about 70,044 man-rem/year (based on 90 mreinfyrfor natural background).
El-12
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 6 Doses from Liquid Effluents Second Quarter*
Individual Doses (mrem)
Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0
Recreation 0
Water Ingestion 0
Total 0
1.5 mrem 0 %
Liver Fish Ingestion 0
Recreation 0
Water Ingestion 0
0 Total 0
5 mrem0 Thyrold Fish Ingestion 0
Recreation 0
l Water Ingestion 0
Total 0
5 mrem 0 %
- No liquid releases were made this quarter.
Average Riverflow past BFN (cubic feet per second): No Release Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)
Population doses can be compared to the natural background dose for the entire SO-mile population of about 70,044 man-rem/year (based on 90 mremlyr for natural background).
EI-13
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 7 Doses from Liquid Effluents Third Quarter Individual Doses (mrem)
Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Child Total Body Fish Ingestion 2.7E-08 Recreation 0
Water Ingestion 2.2E-06 Total 2.2E-06 1.5 mrem
<1%
Child Bone Fish Ingestion 2.7E-08 Recreation 0
Water Ingestion 2.2E-06 Total 2.2E-06 5 mrem
<1 %
Child Thyrold Fish Ingestion 2.7E-08 Recreation 0
Water Ingestion 2.2E-06 Total 2.2E-06 5 mrem
<1 %
- AlI dose Is from an abnormal liquid release this quarter.
Average Riverflow past BFN (cubic feet per second): 23902 Population Doses Total Body Dose 3.8E-05 man-rem Maximum Organ Dose (organ) 3.8E-05 man-rem (bone).
Population doses can be compared to the natural background dose for the entire SO-mile population of about 70,044 man-rein/ear (based on 90 mremfyrfor natural back-ground).
EI-14
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 8 Doses from Liquid Effluents Fourth Quarter Individual Doses (mrem)
Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Child Total Body Fish Ingestion 2.6E-08 Recreation 0
Water Ingestion 2.1E-06 Total 2.1E-06 1.5 mrem
<1 %
Child Liver Fish Ingestion 2.6E-08 Recreation 0
Water Ingestion 2.1E-06 Total 2.1E-06 5 mrem
<1 %
Child Thyroid Fish Ingestion 2.6E-08 Recreation 0
Water Ingestion 2.1E-06 Total 2.1E-06 5 mrem
<1 %
- All dose is from an abnormal liquid release this quarter.
Average Riverflow past BFN (cubic feet per second): 59905 Population Doses Total Body Dose 3.5E-05 man-rem Maximum Organ Dose (organ) 3.5E-05 man-rem (bone)
Population doses can be compared to the natural background dosefor the entire 50-mile population of about 70,044 man-reinfyear (based on 90 mrem4yrfor natural background).
El-15
Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 9 Total Dose from Fuel Cycle First Second Third Fourth Dose Quarter Quarter Quarter Quarter Total Body or any Organ (except thyroid)
Total body air submersion 2.7E-04 9.4B-04 1.6E-03 2.8E-03 Critical organ dose (air) 1.4E-02 8.3E-03 1.6E-02 4.4E-02 Total body dose (liquid) 0 0
2.2E-06 2.1E-06 Maximum organ dose (liquid) 0 0
2.2E-06 2.IE-06 Direct Radiation Dose 0
0 0
0 Total 1.4E-02 9.2E-03 1.8E-02 4.7E-02 Cumulative Total Dose (mrem)
(Total body or any other organ) 8.8E-02 Annual Dose Limit (mrem) 2.5E+01 Percent of Limit
_<1%
Thyroid Dose (mrem)
Total body air submersion 2.7E-04 9.4E-04 1.6E-03 2.8E-03 Thyroid dose (airborne) 4.1E-02 2.4E-01 1.9E.02 6.5E-01 Total body dose (liquid) 0 0
2.2E-06 2.1E-06 Thyroid dose (liquid) 0 0
2.2E-06 2.1E-06 Direct Radiation Dose 0
0 0
0 Total 4.1E-02 2.4E-01 2.1E.-02 6.5E.Ol Cumulative Total Dose (Thvroid) mrem 9.6E-01 Annual Dose Limit (mrem) 7.5E+01 Percent of Limit 1.3 %
E1-16
ENCLOSURE 2 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)
A UNITS 1, 2, AND 3 METEOROLIGICAL DATA TABLES JANUARY THROUGH DECEMBER 2002 E2-1
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY DECEMBER 2002 TABLE 10 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FIRST QUARTER
(
E2-2
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 *18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.047 0.189 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 1.040 0.615 0.709 0.567 0.000 0.041 0.095 0.047 0.000 0.000 0.236 0.095 0.000 0.000 0.000 0.000 0.473 0.047 0.378 0.095 0.047 0.000 0.142 0.095 0.047 0.189 0.567 0.331 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.615 0.804 0.757 0.142 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.284 0.189 0.615 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 94f,
- 0. £15 0.0(o3 0.000 0.000 0.095 I. 5fA)
O.*157 I. 1 35
- 0. 85 I
- 0. 09',
(3.
0415
- 0. 3.10 I.04*
I.04(3 I. St; SUBTOTAL 0.000 0.000 0.473 1 3.215 1.844 3.262 1.371 0.000 0.000 I0. Ib5 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 215 215 2115 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/15' MEAN WIND SPEED =
7.66 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-3
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M) browns Ferry Nuclear Plant JAN 1, 2002 - MAR 31, 2002 WIND SPEED(MPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4.18.5-24.4
>=24.S TOTAL b.
WIND DIRECTION CALM N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.189 0.142 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.473 0.000 0.000 0.000 0.000 0.047 0.000 0.236 0.142 0.047 0.000 0.000 0.047 0.142 0.047 0.047 0.000 0.757 0.047 0.426 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.000 0.000 0.047 0.000 0.142 0.000 0.000 0.804 0.142 0.095 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.189 0.236 0.189 0.993 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.331
- 0. 189 0.000 0.567
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
'O.000 0.000 0.000 0.000 0.000 9.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 1I9U
- 0. 52(
0.047 0.000 0.047 0.047
- 0. 331
- 0. 33 I 0.2u4 0.000 0.047
- 0. 142 O.:- it, 0.709 0.4.13
- 0. I189 3.59 3 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 76 76 2115 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/!S MEAN WIND SPEED -
7.89 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-4
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
ESE SE ssE S
WNW NW NNW SUBTOTAL
- 0. 000
- 0. 000 0.000 0.000 0.000
- o. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.095 0.000 0.095
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.284 0.095 0.189 0.095 0.000 0.000 0.047 0.000 0.047 0.047 0.142 0.331 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.095 0.095 0.000 0.000 0.757 0.000 0.095 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.142 0.236 0.331 0.946 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.236 0.189 0.095 0.520 0.000
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 095 0.000 0.000 0.095 0.000 0.000 9.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 1412 0.42't 0.047 0.00()
0.000 0.t047
- 0. 37if 0.2 It,
- 0. 28.1
(. 14.
- 0. 1
- 0. (I'/
I). 1.1'
- 0. S.-/
(0..11 /
- 0. 4 / 1 3.49J1 0.331 0.851 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 74 74 2115 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 200 2/0 15/!s MEAN WIND SPEED =
8.02 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-5
JoINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4
.18.5-24.4
>=24.5, TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.142 0.331 0.236 0.331 0.284 0.189 0.520 0.615 0.378 0.331 0.142 0.236 0.142 0.095 0.095 0.095 0.426 0.709 0.520 0.520 0.236 0.236 0.709 0.567 0.189 0.331 0.142
- 0. 095' 0.284 0.142 0.236 0.378 0.662 1.040 0.757 0.189 0.142 0.142 0.189 0.047 0.473 0.000 0.000 0.142 0.520 0.236 0.473 0.709 2.364 0.757 0.378 0.000 0.047 0.142 0.284 0.000 0.142 0.047 0.047 0.142 0.662 0.804 2.270 2.128 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 1.229 1.986 0.473 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.142
- 0. 142 0.047 0.000 0.000
- 0. U00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 3. t,HH 2.837 1.891 I.0H7 0.70')
0.804 I.7702 I.229
- 1. I H'.
- 0. 7""
- 0. 3 I1
- 0.., I5 I. fA 2.E.18 5.201 3.830 SUBTOTAL 0.000 0.142 4.161 5.721 5.721 10.213 3.783 0.378 0.000 30.118 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 641 637 2115 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/1!
MEAN WIND SPEED -
7.73 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-6
Jo1INT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 - MAR 31, 2002 WIND
)IRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4.18.5-24.4 CALM i=)4.5,
TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.b00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.095 0.047 0.047 0.000 0.047 0.000 0.047 0.047 0.426 0.426 0.284 0.142 0.142 0.473 0.993 1.087 0.898 0.851 0.662 0.426 0.520 0.520 0.000 0.284 0.189 0.567 0.331 0.615 0.095 0.095 0.284 0.615 1.466 2.175 0.709 0.047 0.095 0.426 0.000 0.426 0.757 0.426 0.426 0.236 0.142 0.047 0.142 0.236 0.095 1.182 0.189 0.047 0.000 0.473 0.236 0.378 0.520 4.775 0.331 0.142 0.047 0.000 0.000 0.000 0.047 0.189 0.709 0.142 0.047 0.047 0.000 0.236 0.520 0.331 2.790
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
(.000 0.000 0.000 o;.000 0.000 0.000 J. 000 0.n00 0.000 0.000 0.000 0.000 0.000 0.000 0.0o0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 I.74 9 1.182
- 1. 040
- 0. 378 0.615 1.418 I. 98,
2./74-1Z 5.012
- 1. 74" 0.f61!,
- 0. t 1.'
I.4*6.
- 0. 4/1
- 1. 102 1.81) I 7.896 8.700 0.000 24.e.HI TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 525 522 2115 0
METEOROI.OGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/I-'
MEAN WIND SPEED =
4.65 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-7
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F 1 1.5< DELTA Tc-4.0 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 - MAR 31, 2002 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 -18.5-24.4
=24.5,
TOTAL N
NNE NE ENE E
WNW NW 101W 0.004 0.001 0.001 0.003 0.003 0.002 0.010 0.010 0.004 0.002 0.001 0.000 0.001 0.001 0.001 0.003 0.047 0.000 0.000 0.000 0.047 0.047 0.095 0.142 0.189 0.142 0.095 0.047 0.095 0.000 0.000 0.142 0.615 0.236 0.236 0.520 0.473 0.378 1.702 1.513 0.473 0.236 0.095 0.000 0.000 0.095 0.142 0.331 0.567 0.378 0.142 0.095 0.567 0.047 0.567 0.378
- 1. 135 0.331 0.095 0.00o 0.000 0.047 0.095 0.898 0.000 0.095 0.047 0.047 0.000 0.000 0.047 0.236 0.898 0.236 0.000 0.000 0.000 0.000 0.095 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.993 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 O. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. noo 0.000
- 0. 000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 I.23.1 0..,I I 0.42) 0.665 I.09(
0.475 2.422 2.32
- 3. 69-
- 0. 995
- 0. 285
- 0. U4t'
- 0. 095 0.142 0.3J2 1.4t,1 SUBTOTAL 0.047 1.087 7.045 1 5.343 1.797 1.087 0.000 0.000 0.000 Ib. 4t07 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 350 347 2115 1
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/1'.
MEAN WIND SPEED =
3.78 NOTE:
TOTAL.S AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-8
JOINT 1' PRCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABIILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 -
MAR 31, 2002 WIND
)IRECTION WIND SPEEDIMPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 I8.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.236 0.095 0.000 0.000 0.000 0.095 0.047 0.662 0.095 0.000 0.000 0.000 0.095 0.047 0.095 0.047 1.513 0.426 0.189 0.047 0.284 0.047 0.047 0.898 3.546 1.087 0.000 0.047 0.000 0.000 0.142 0.047 0.615 7.423 0.378 0.142 0.000 0.000 0.000 0.047 0.047 0.804 0.615 0.000 0.000 0.000' 0.000 0.000 0.000 0.095 2.128 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.331 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.473 0.000 0.000 0.000 0.000.
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000.
- 0. 000 0.000
- q. 000 0.000 0.000 0.000 0.000 0.000 0.000
.0.000 0.000
'. 000 0.000 0.000 0.000 0.000 0.000 1.040 0.42 6 0.047 0.284 0.047 0.189 1.040
- 5. 0',1) 2.128
- 0. 001)
- 0. 04*1
- 0. 0oo
'0.0'5
- 0. 189 0.142 0.804 11. bIl TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 244 244 2115 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/15.
MEAN WIND SPEED =
2.73 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-9
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 11 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES SECOND QUARTER E2-10
JOInT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M3 Browns Ferry Nuclear Plant APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 -18.5-24.4
>=24.5 TOTAL.
N NNE NE ENE E
WNW NW NNW
- 0. 000 0.000 O.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.473 0.757 1.041 0.237 0.047
- 0. 000 0.000 0.000 0.000 0.000 0.047
- 0. 000 0.000 0.000 0.000 0.473 2.366 0.615 0.899 0.805 0.331 0.331 0.095 0.047 0.047 0.047 0.142 0.142 0.000 0.047 0.000 0.947 0.426 0.095 0.000 0.000 0.000 0.000 0.095 0.095 0.142 0.047 1.609 0.663 0.000 0.000 0.000 0.237 0.095 0.000 0.000 0.000 0.000 0.047 0.000 0.331 0.473 0.284 0.047
- 0. 000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.142 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 9.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 1.846 0.8 (5 0.047 0.047 0.000 I. 65C 3.360
- 1. 4e.7 1.940 1.041 0.179 0.379
- 0. 189 0.521
(.805
- 0. 5' I SUBTOTAL 0.000 0.000 2.556
, 6.105 2.177 3.739 0.379 0.047
- 0. 000 15.002 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 317 317 2113 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =
6.09 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-11
J(INI IERCENIAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/t00 M)
Browns Ferry Nuclear Plant APR 1, 2002 -
JUN 30, 2002 WIND
)IRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5 CALM
-7.4 7.5-12.4 12.5-18.4
- 18.5-24.4
=24.5 b
TOTAl.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.237 0.284 0.237 0.379 0.189 0.095 0.000 0.047 0.000 0.000
- 1. 467 0.047 0.047 0.000 0.000 0.000 0.284 0.189 0.047 0.237 0.331 0.331 0.473 0.142
- 0. 000 0.000 0.000 2.130 0.000 0.095 0.000 0.047 0.000 0.095 0.095 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.095 0.047 0.568 0.189 0.189 0.189 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.047 0.047 0.047 0.189 0.000 0.899 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000
- 0. 000 0.000 0.000 0.217
- 0. JJ9
- 0. 189 0.047 0.000 0.3719 0.521
- 0. 3.1SI 0.S2 I 0.7 I (
- 0.
'2I
- 0. tC
- 0. Id"1
- 0. 142
- 0. I 31 0.047
!5. I'Jj' TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 110 109 2113 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRIN':ED: 20U2/011/Ui, MEAN WIND SPEED =
5.22 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-12
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5 ;-7.4 7.5-12.4 12.5-18.4
-18.5-24.4
>=24.5,
TOTAL N
NNE NE ENE E
WSW W
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047
- 0. 142 0.331 0.284 0.284 0.237 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0;047 0.284 0.142 0.142 0.095 0.189 0.237 0.047 0.095 0.000 0.047 0.047
- 0. 000 0.095 0.000 0.142 0.000 0.095 0.047 0.000 0.095 0.000 0.000 0.047 0.047 0.095 0.189 0.000 0.189 0.047 0.142 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.284 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.1I09 0.142 0.142 0.237 0.04) 0.473
- 0. 3 31 0.473 0.473
- 0. 473
(. *11 I (3.
095
- 0. IH0 0.142
- 0. (. I 0.142 0.000 0.000 1.372
, 1.467 0.852 0.852 0.095 0.000 0.000
- 4. 6 38 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 101 98 2113 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/0H/01, MEAN WIND SPEED =
5.48 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-13
JuINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4
'18.5-24.4 CALM
>=24.5
- TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.047 0.000 0.000 0.000 0.047 0.000 0.237 0.047 0.142 0.047 0.142 0.142 0.473 1.230 0.947 1.514 1.514 0.568 0.615 0.331 0.237 0.142 0.047 0.237 0.284 0.237 0.237 0.473 1.609 1.325 0.284 0.426 1.088 0.237, 0.331 0.331 0.568 0.331 0.331
- 0.379 0.426 0.426 0.095 0.142
- 1. 183 0.331 0.047 0.237 0.379 0.000 0.095 0.095 0.237 0.710 0.237 5.017 0.757 0.568 0.142 0.000 0.000 0.189 0.047 0.000 0.000 0.000 0.000 0.284 0.047 0.284 0.899 0.663 3.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.426 0.521 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 1.42U 1.420 0.852 0.473
- 0. 757
- 3. 45 2.94 1.27H 2.224
- 3. (0/6 0.082 1 325
- 0. H05 I
. 372 2.224
- 1. 704
- 26. 17 1 8.140 i 8.329 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 562 553 2113 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED:
2002/011/0I.
MEAN WIND SPEED =
5.12 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-14
JOINT P'ERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 - JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5 TOTAL.
N NNE NE ENE E
WIW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.142 0.095 0.095 0.331 0.095 0.189 0.189 0.095 0.000 0.142
- 0. 095 0.047 0.047 0.000 0.710 0.331 0.805 0.757 1.325 2.035 1.562 0.899
- 1. 183 0.615 0.284 0.284 0.521 0.000 0.142 0.237 0.994 0.473 0.473 0.757 2.035 1.562 0.379 0.284 0.426 0.805 0.000 0.189 0.331 0.047 0.189 0.142 0.710 0.284 0.615 0.189 0.142 0.379 0.047 0.237 0.142 0.379 0.000 0.000 0.000 0.047 0.095 0.284 0.331 0.237 0.237 0.000 0.047 0.000 0.000 0.095 0.189 0.047 0.000 0.047 0.000 0.047 0.142 0.095 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.047 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
-0.000 0.000 0.000 0.000 p.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.792 1. 420 2.272 1.798 3.644 4.30)7
- 2. (JH2 1.7114 2.l117 I. 91o)
- 0. 21i4
- 0. Stj I
- 0.947
- 0. 189
- 0. 615 0.7',
SUBTOTAL 0.000 1.704 11.690 9.087 3.549 1.514 0.047 0.000 0.000 27.j91 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 585 583 2113 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED:
2002/08/0l.
MEAN WIND SPEED =
3.89 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-15
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F 1 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 '18.5-24.4 CALM
>=24.5 b T9TAI.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.095 0.237 0.095 0.237 0.142 0.521 0.568 0.189 0.095 0.142 0.047 0.142 0.095 0.047 0.047 2.792 0.521 0.473 0.805 0.663 1.088 0.852 0.899 0.379 0.379 0.331 0.095 0.095 0.331 0.000 0.047 0.284 0.379 0.663 0.142 0.189 0.568 0.095 0.095 0.142 0.237 0.000 0.000
- o. oo0 0.047 0.000 0.142
- 0. 189 0.095 0.095 0.142 0.095 0.047 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.663 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000
- 0. 000
- 0. 000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0(0 0.000 0.000 0.000 0.000 0.000 1.0OH 1.325 I. 325 1.041 1.940
- 1. 0H8 1.514
- 1. 2,1
- 0. 1105 0..426 0.2 0R
. 0.14.'
0).52 I O. o-11 0.241
- 0. 2 37 Ii. 671 7.241 2.887 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 290 289 2113 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/08/0f*,
MEAN WIND SPEED =
2.69 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-16
JoiNT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 - JUN 30, 2002 WIND IRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 -18.5-24.4
>=24.5,
TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.331 0.189 0.095 0.237 0.237 0.142 0.284 0.284 0.047 0.000 0.047 0.000 0.047 0.189 0.095 0.142 1.183 0.710 0.473 0.568 0.142 0.047 0.047 0.189 0.189 0.047 0.047 0.000 0.000 0.000 0.142 0.757 0.331 0.189 0.000 0.095
- 0. 095
- 0. 000 0.000 0.047 0.095 0.000 0.000
- o. ood 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 o
0.000 I1.
0 4
- 1. 088
- 0. 56H 0.899 0.473 0.189
- 0.
3: 1
- 0. 52 1 U. 3 If 0.047
- 0. (I'),
- 0. 010
- 0. 1)4.1
(. 109 0.2 J3
- 0. H9'J UBTOTAL 0.000 2.366 4.543 1 0.852 0.000 0.000 0.000 0.000 0.000
- 7. 7tI TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 165 164 2113 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: ;'002/O0/0e, MEAN WIND SPEED =
2.07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-17
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 12 JOINT FREQUENCY DISTRIBUTIO9 IN PERCENT FOR GROUND LEVEL RELEASES THIRD QUARTER E2-1 8
JoItlT PERCE:NITAGE FREQUENCIES UF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<--l.9 C/100 M)
Browns Ferry Nuclear Plant JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7;4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTtAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.185 1.066 0.974 0.278 0.139 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.278 1.437 1.762 1.113 0.788 0.742, 0.417 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.371 0.046 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.185 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000' 0.000 0.000 0.000 0.000 0.000 0O 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. Iti-
- 0. 139 0.0(10 0.000 0.04 6 0.649 I. 6I9' 2.8020 2.Otto.
I. 0LR
- 0. 4-I I 0.'. 1(
- 0. 1)1((
0.000 0.04 6 0.(046 0.000 0.000 2.689
. 6.583 0.556 0.371 0.000 0.000 0.000 1(. 199 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 221 220 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/0.
MEAN WIND SPEED -
4.16 NOTE:
TOTALS AD)
SUBTOTA1.S ARE OBTAINE1J FROM UNROUNDED NUMBERS E2-19
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 Hw Browns Ferry Nuclear Plant JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 t8.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046
- 0. 185 0.834 0.510 0.556 0.232 0.046 0.000 0.000 0.000 0.000 2.457 0.046 0.000 0.000 0.000 0.093
'0.139 0.185 0.278 0.232 0.232 0.464 0.371 0.185 0.046 0.093 0.046 2.411 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.093 0.000 0.046 0.325 0.046 0.371 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.046 0.603 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.0()0 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.093 0.371 0.046
- 0. O0U 0.139 0.270
- 0. J 1 I
- 1. 11 I 0.74;'
(. 7tti1 0.
- 0. 4 I 1
- 0. "III I
. _ I,
- 0. 093
(). I.1')
- 5. 19'i TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 126 125 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/0U MEAN WIND SPEED -
4.20 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-20
JOINT PERCENlTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABII.ITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4
'18.5-24.4
>=24.5,
TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.093 0.603 0.325 0.695 0.695 0.417 0.093 0.046 0.046 0.046 0.000 0.093 0.093 0.093 0.000 0.093 0.232 0.000 0.000 0.093 0.139 0.232 0.556 0.185 0.093 0.000 0.000 0.000 0.139 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.185 0.093 0.093 0.139 0.232 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.185 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000
- o. oon
- o. doo 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 o 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.278 0.4t4 0.093 0.000 0.093 0.371 0.603
- 0. 32' 0.')HH 0.H 14
- 0. t,61')
- 0.
f,95
- 0. 4 17
- 0. 325 0.32"
- 0. 1 39 SUBTOTAL 0.000 0.000 3.106
, 1.901 0.742 0.649 0.000 0.000 0.0(0 6.390 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 139 138 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/0u MEAN WIND SPEED =
4.32 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-21
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(HPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 *18.5-24.4
>=24.5,
TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.139 0.000 0.093 0.000 0.000 0.000 0.000 0.417 0.371 0.417 0.417 0.510 0.881 1.391 1.205 1.854 2.550 1.484 1.854 0.881 0.278 0.185 0.278 0.417 0.417 0.510 0.371 0.603 1.808 0.464 0.139
- 0. 185 0.185 0.232, 0.695 1.205 0.742 0.510 0.278 0.695 0.556
- 0. 185 0.325 0.185 0.881
- 0. 185 0.000 0.000 0.046 0.000 0.046 0.325 0.788 0.556 0.417 0.278 0.649 0.325 0.232 0.139 0.139 0.000 0.000 0.046 0.185 0.000 0.000 0.093 0.4f64 0.695 0.464 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.04 6 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
.0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.808 2.040 1.437 1.344 1.437 3.709 2.0H6 1.391 2.111
- 3. IOte 1.715
- 2. L1 2.501
- 1. 9'i4 1.43I
- 0. 000 0.371 14.975 8.762 5.192 3.709 0.093 0.000 0.000
.]J. 10(1 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2188 728 714 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/01 MEAN WIND SPEED -
4.36 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-22
JWINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/l00 M)
Browns Ferry Nuclear Plant JUL 1, 2002 - SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.185 0.278 0.232 0.185 0.000 0.139 0.232 0.325 0.185 0.139 0.046 0.046 0.046 0.046 0.139 0.927 0.788 1.020 1.391 1.576 1.947 1.020 0.510 0.927 0.927 0.603 0.649 0.510 0.232 0.325 0.464 0.927 0.788 0.510 0.742 1.576 1.252 0.139 0.000 0.000 0.000 0.000.
0.046 0.371 0.000 0.139 0.417 0.510 0.695 0.649 0.232 0.185 0.139 0.093 0.000 0.046 0.093 0.000 0.000 0.232 0.093 0.000 0.046 0.093 0.371 0.232 0.000 0.139 0.046 0.000 0.046 0.046 0.139 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000
- 0. 000
-0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 o
0.0(0 2.503 2.828 2.609 2.5 96 3.662 3.384 1.391 0.788 I
. 344 1. 344 0.742
. O.'142 1.2'.2
- 0. -3'l 0. ! I I.u6 SUBTOTAL 0.000 2.272 13.815 1 6.908 3.013 1.205 0.000 0.000 0.000 27.214 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 598 587 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/oi MEAN WIND SPEED -
3.49 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-23
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant JUL 1, 2002 - SEP 30, 2002 WI ND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 '18.5-24.4
>=24.5 b TqTAL N
NNE NE ENE E
WNW NW "8NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.232 0.325 0.000 0.139 0.046 0.093 0.278 0.139 0.000 0.000 0.093 0.000 0.093 0.139 0.000 0.139
- 1. 159 0.881 0.417 0.881 0.556 0.185 0.093 0.093 0.000 0.000 0.046 0.046 0.093 0.185 0.325 0.417 1.066 1.252 0.185 0.417 I
0.603 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.046 0.046 0.046 0.046 0.185 0.046
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.501
- 2..4 3
0.649 1
. 4 17 1.205
- 0. 27H
- 0. 371 0.2I2
- 0. I0(}
- 0.
00(
- 0. III 0.U4 b
- 0..' 1 '
).
371
- 0. 171
- 0. fm i SUBTOTAL 0.000 1.715 5.378 I
3.755 0.278 0.000 0.000 0.000 0.000 I
. I 27 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 241 240 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/oA MEAN WIND SPEED =
2.89 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-24
JoiN*T PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEEDIMPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
-=24.5 '
TQTAI.
N NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.371 0.371 0.510 0.046 0.046 0.000 0.046 0.000
- 0. 000 0.000 0.093 0.000 0.04 6 0.000 0.000 0.325 0.881 0.695 0.556 0.649 0.325 0.093 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.371 0.278 0.000 0.046 0.139 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000
- 0. 000 0.000 b.0ooo 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. ((O 0.000
- 0. 000 0.000I 0.000 I.5 0(
I. I 1.,
I. I 1.3 0.834 0.417 0.093 0.04 L
(). 00(i
- 0. 04i1
- 0. 0I
- 0. 000
- 0. 04 t.
- 0. 0(U
(. ()00 0.834 SUBTOTAL 0.000 1.854 3.616 1 0.649 0.046 0.000 0.000 0.000 0.000
- b.
I t,.
TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 135 133 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/(J MEAN WIND SPEED -
2.14 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-25
I RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 13 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FOURTH QUARTER E2-26
.JOINTr PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WI ND)
DIRECTION WIND SPEED(MPIH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 b
TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.139 0.277 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 I 0.000 0.092 0.416 0.139 0.462 0.185 0.046, 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.6000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000
'. i.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 092
- 0. ()0()
0.000 0.000 0.000 0.139 0.416 0.277 0.740
- 0. IH5 0.04to
- 0. 0(0 0.000 o.000 0.092 0.046 SUBTOTAL 0.000 0.000 0.462 e 1.341 0.000 0.092 0.139 0.000 0.000 2.034 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 44 44 2163 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/0U MEAN WIND SPEED -
4.86 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-27
JOINTI PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4
- 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.185 0.185 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.324 0.046 0.139 0.092
- 0. 09z 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.092 0.139 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.046 0.139 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.046 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 T.000 0.000 0.000 0.000 0.000 0.000 0.000 o
0.000
- 0. 185 0.092 0.046 0.046 0.04f6 0.046 0.41If 0.23 1 0.324 0.13'9 0.119
. 0. (J9' 0.092 0.046
- 0. 1 39 0.277 SUBTOTAL 0.000 0.000 0.555 i 0.786 0.324 0.462 0.231 0.000 0.000 2.35H TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 51 51 2163 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/U0/v07 MEAN WIND SPEED =
6.31 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-28
JO11JT PERCEJTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 -18.5-24.4 CALM
-24.5,
TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.185 0.139 0.185 0.000 0.046 01000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.185 0.046 0.046 0.092 0.185 0.046 0.092 0.000 0.092 0.000 0.092
- 0. 000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.231 0.000 0.416 0.185 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.185 0.185 0.370 0.971 0.046 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.139 0.046 0.416 0.000 0.000
- 0. 0a0o 0.00 0.000 O.'000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000
.0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.27) 0.00(1 0.046
- 0. (00
- 0. 000
- 0. 1Il5
(). 1015 0.2 11 0.21I
(. 371)
- 0. (04t, 0.21L 0.0'1' 0.4 62
(. 5 S 0.509 3.421 0.693 0.925 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 74 74 2163 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/01 MEAN WIND SPEED =
7.06 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-29
.JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4' 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.046 0.046 0.046 0.092 0.000 0.000 0.000 0.000 0.092 0.647 0.277 0.462 0.740 0.925 0.647 1.526 1.757
- 1. 479 0.647 0.555 0.416 0.462 0.185 0.277 0.370 1.341 1.248
- 1. 156 0.370 1.248
' 1.942 0.555 0.693 0.370 0.092 0.324 0.277 0.555 0.832 1.248 1.110
- 13. 361 1.017 1.017 0.462 0.324 0.04 6 1.526 0.185 0.04 6 0.046 0.092 0.000 0.231 0.832 0.878 0.509 1.202 8.414 0.555 0.693 0.324 0.046 0.092 0.277 0.185 0.046 0.000 0.000 0.000 0.277 0.971 1.248 1.849 3.282 9.847 0.000 0.092 0.139 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.231
- 1. 110 1.063 0.370 3.098 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.092 0.000 O.000 0.000 0.000
- 0. 000
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL.
1..
3.5t.0Z
- 3. 32"
- 2. 5H'J I
. 526 2.312 4. 4 18 2.497 2.5 H9 I.94.!
- 0. H/H
- 0. 9'11 I.;'( '0
.3.
Oj,1
- 4. 100 4.9') 1 6.4 2;
- 46. 4,0' 0.416 11.373 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS IIOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OF VALID WIND DIRECTION-WIND SPEED-STABILITY CALM CLASS D OBSERVATIONS 2172 1013 1008 2163 0
METEOROLOGICAL FACII.ITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/0).
MEAN WIND SPEED =
6.05 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-30
JorIT P'ERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 *18.5-24.4
>=24.5 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.046 0.185 0.046 0.185 0.324 0.139 0.139 0.139 0.000 0.185 0.046 0.092 0.092 0.139
- 0. 509 0.601 0.370 0.509 0.740 1.063 0.878 1.618 1.711 0.370 0.555 0.509 0.2-77 0.139 0.324 0.647 0.878 0.370 0.092 0.277 0.370 0.509 0.324 0.647 0.878 0.509 0.092 0.37d 0.231 0.092 0.231 0.878 0.462 0.277 0.185 0.046 0.000 0.416 0.324 0.509 0.647 0.092 0.000 0.370 0.139 0.139 0.185 0.509 0.185 0.000 0.000 0.092 0.000 0.185 0.231 0.000 0.462 0.231 0.000 0.046 0.046 0.000 0.092 0.324 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 o
TOTAL.
2.00 1.341 0.693 1.110 1.l156 2.358 2.080 2.913 3.H0 7 1.34 1
- 0. 647 1.479 0.740
- 0. 4f2 1. 0 1' 2.543 0.000 1.896 10.818 f 6.750 4.300 1.896 0.139 0.000 0.000 25.79H TOTAL TOTAL TOTAL TOTAL TOTAL MOURS IIOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY' OBSERVATIONS CALM 2172 561 558 2163 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =
4.01 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-31
.JolrT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear PlaInt OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 *18.5-24.4 CALM
>=24.5,
TOTAL.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.185 0.092 0.000 0.092 0.092 0.277 0.231 0.046 0.092 0.046 0.139 0.000 0.046 0.000 0.046 1.433 1.063 0.416 0.277 0.231 0.740 0.555 0.740 1.341 0.786 0.324
- 0. 185 0.092 0.092 0.046 0.092 0.601 0.971 0.277 0.000 0.046 0.231 0.000 0.324 0.370 0.416 0.000 0.000 0.006 0.000 0.000 0.000 0.416 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.231 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.462 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.092 0.277 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.0H0 0.H878 0.370 0.277 1.063 0.647 1.433 2.034 I.618
- 0. 4 1 6 0.231 0.231 0.092
- 0. 092 0.119 1.202
- 12. 80t 7.582 3.051 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 278 277 2163 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED -
2.90 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-32
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5,
TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.509 0.416 0.139 0.046 0.092 0.231 0.092 0.185 0.185 0.000 0.000 0.000 0.046 0.046 0.092 0.092 1.063 0.416 0.462 0.509 0.092 0.139 0.139 1.063 0.139 0.000 0.000 0.000 0.046 0.000 0.046 0.277 0.277 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000' 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.849 0.832
- 0. 601 0.555 0.185 0.370 0.231 I.341
- 0. 3*10
- 0. 0o0
- 0. 0(O
- 0.
00o 0
(. (92 0.046
- 0. '1'1'
- 0. 370 SUBTOTAL 0.000 2.173 4.392
- 0.370 0.046 0.000 0.000 0.000 0.000 6.981 TOTAL HOURS OF VAI.ID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 151 151 2163 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 200J/02/l0l MEAN WIND SPEED -
2.03 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-33
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 14 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES A(GROUND LEVEL PORTION)
FIRST QUARTER E2-34
StIT~r JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 - MAR 31, 2002 WIND DIRECTION WIND SPEED(MPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM
>-24.5 T6TAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.059 0.033 0.070 0.047 O.006 0.000 0.000 0.000 0.000 0.000 0.209 0.019 0.010 0.000 0.000 0.000 0.000 0.070 0.008 0.072 0.018 0.007 0.000 0.015 0.004 0.002 0.014 0.240 0.078 0.051 0.000 0.000 0.000 0.017 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.087 0.122 0.117 0.490 0.034 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.054 0.037 0.124 0.279 0.000 0.000 0.000 0.000 O. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 o0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.130
- 0. oHo 0.000 0.000 0.00(o 0.017
- 0. I29 0.041
- 0. I1.,
- 0. (3 El. ElI) I
- 0. U(JO)
(3.04 I
". 14 5
- 0. 11.2
(..25 1. L21 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2108.000 310.980 25.860 25.860 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/05/11i NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-35
SPI.IT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-l.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 -
MAR 31. 2002 WIND DIRECTION WIND SPEED(MP1i) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 18.5-24.4 CALM 7.5-12.4 12.5-18.4
>=24.5 TdTA1.
N NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.006 0.000 0.000 0.006 0.002 0.000 0.000 0.000 0.000 0.006 0.040 0.000 0.000 0.000 0.009 0.009 0.000 0.009 0.000 0.000 0.007 0.000 0.009 0.000 0.000 0.022 0.011 0.007 0.000 0.000 0.000 0.000 0.000 0.016 0.000 0.000 0.000 0.009 0.027 0.037 0.031
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.096 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0 'H 0.(51 0.007 0.000 0.000 0.009 0.022 0.007 0.0(25
- 0. (0)0
- 0. (0(
0. 0(9 0.01H 0.131
- 0. OO 0.0 31 SUBTOTAL 0.000 0.000 0.003 0.019 0.087 0.160 0.148
- 0. 000 0.000
- 0. 4 1H TOTAL TOTAL TOTAL TOTAL 1fOURS HOURS tHOURS 11OURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2108.000 310.980 8.810 8.810 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/05/15 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-36
SPLIT.JOIJT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR sTABllITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 - MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH1) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TQTAI.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.009 0.000 0.010 0.010 0.000 0.000 0.000 0.000 0.000 0.001 0.017 0.027 0.000 0.000 0.000 0.000 0.007 0.026 0.000 0.000 0.000 0.000 0.003 0.004 0.000 0.000 0.083 0.000 0.014 0.006 O. 000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.009 0.000 0.022 0.037 0.057 0.155 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.062 0.059 0.019 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.075 0.000 0.000 0.075 0.000 9.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 I 0.000 0.000
- 0. OI /
0.041 0.006 0.000
- 0. 000 0.004 0.017 0.024,
- 0. 014) 0.020) 0.1)01)
- 0. 009 0.00 I
- 0. 1I,3
- 0. 0'if, 0.077
- 0. 48H 0.000 0.035 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2108.000 310.980 13.020 10.280 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2002/05/15 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-37
Sl'LIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.002 0.010 0.011 0.000 0.010 0.000 0.001 0.000 0.000 0.000 0.000 0.023 0.040 0.015 0.019 0.009 0.014 0.055 0.080 0.027 0.048 0.019 0.004 0.013 0.001 0.002 0.019 0.082 0.127 0.064 0.020 0.020 0.026 0.035 0.014
- 0. 101 0.000 0.000 0.023 0.058 0.018 0.042 0.085 0.424 0.126 0.056 0.000 0.009 0.022 0.126 0.000 0.054 0.018 0.010 0.028 0.103 0.126 0.381 0.363 0.029 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.016 0.384 0.64 6 0.198 0.047 0.000 0.000 0.000 O..000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.097 0.045 0.000
,0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000' 0.000 0.605 0.294 0.135 0.040 0.03H 0O
.0f5 0.225
- 0. 104
- 0. IHI 0.O/6
- 0. 029
- 0. I,)(
0.f.22 0. 19 0.71t1 SUBTOTAL 0.000 0.000 0.036 1 0.386 0.713 1.846 1.273 0.284 0.000
- 4. 53H TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2108.000 310.980 1007.200 95.660 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 H/S DATE PRINTED: 2002/0S/15 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-38
siPLT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH1) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 b.
>=24.5 TOTAL.
N NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.003 0.003 0.000 0.021 0.033 0.068 0.061 0.057 0.035 0.013 0.025 0.017 0.000 0.004 0.002 0.077 0.037 0.059 0.009 0.011 0.038 0.142 0.319 0.348 0.114 0. 005 0.009 0.038 0.000 0.036 0.075 0.064 0.060 0.036 0.014 0.008 0.025 0.123 0.042 0.301 0.044 0.008 0.000 0.063 0.026 0.050 0.072 0.052 0.027 0.008 0.000 0.000 0.000 0.047 0.190 0.503 0.062 0.009 0.009 0.000 0.040 0.093 0.049 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.011 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 e. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.I196
- 0. 127 0.106 0.021 0.040 0.096 0.301 0.611 1.2 1 0.255
- 0. 015
- 0. 044 0.11H 0.066 0.192 0.209 SUBTOTAL 0.000 0.000 0.348 1.317 0.935 1.090 0.020 0.000
- 0. 000 3.711 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2108.000 310.980 822. 100 78.230 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 MIS DATE PRINTED: 2002/05/15.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-39
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 -
HAR 31, 2002 WI ND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TdTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.010 0.004 0.000 0.000 0.001 0.001 0.000 0.000 0.000 0.035 0.006 0.006 0.026 0.030 0.034 0.148 0.170 0.065 0.025 0.000 0.000 0.000 0.002 0.001 0.020 0.065 0.049 0.019 0.013 0.063 0.008 0.093 0.116 0.220 0.057 0.013 0.000 0.000 0.005 0.009 0.106 0.000
- 0. 015 0.008 0.000 0.000 0.000 0.010 0.158 0.229 0.044 0.000 0.000 0.000 0.000 0.016 0.015 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.047 0.723 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 101 0.070 0.032 0.039 0.097 0.041 0.251 0.501 1.242 0.136 0.01.3 0.001 0.001
- 0. 00u 0.027
- 0. 14 1 SUBTOTAL 0.000 0.022 0.569
' 0.835 0.495 0.781 0.000 0.000
- 0. 000 2.702 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2108.000 310.980 159.840 56.950 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/05/15 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-40
SPLIT JOIIJT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 - MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.001 0.080 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.001 0.000
- 0.015 0.003 0.002 0.122 0.596 0.175 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.033 0.011 0.000 0.000 0.000 0.007 0.010 0.240 0.132 0.000 0.000.
0.000 0.000 0.000 0.000 0.012 0.000 0.000 0.000 0.000 0.000 0.000 0.027 0.043 0.103 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- q. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
'). 000 0.000 0.042 0.012 0.000 0.015 0.003 0.019 0.160 0.959 0.4 16 0.000
- 0. 00O
'0.000
- 0. 00 0.000 0.000 0.043 SUBTOTAL 0.000 0.096 0.947
' 0.444 0.182 0.000 0.000 0.000
- 0. 000
- 1. 669 TOTAL TOTAL TOTAL TOTAL IOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS G GROUND LEVEL STABILITY CLASS G 2108.000 310.980 71.170 35.190 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/0S/1'.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-41
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 15 JOINT FREQUENCY DISTRIBUTION III PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)
SECOND QUARTER E2-42
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<--l.9 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM
>=24.5 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.028 0.053 0.094 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.055 0.213 0.043 0.147 0.144
- 0. 024' 0.017 0.003 0.000 0.000 0.000 0.013 0.012 0.000 0.004 0.000 0.166 0.078 0.047 0.000 0.000 0.000 0.000 0.002 0.004 0.007 0.005 0.338 0.286 0.113
- 0. 000 0.000 0.000 0.071 0.022 0.000 0.000 0.000 0.000 0.009 0.000 0.043 0.070 0.046 0.658 0.016 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.026 0.031 0.028 0.111 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.000 0.032 0.000 Q. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.315 0.124 0.009 0.004 0.000 0.292
- 0. 3 4 1
- 0. 1 4 3 0.241
- 0. 15¶1 0.024 0.(;2I 0.005 0.073
- 0. 139 0.079 1.967 0.183
' 0.646 TOTAL TOTAL TOTAL TOTAL HOURS HOURS IIOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2114.000 231.920
- 41. 580
- 41. 580 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S DATE PRINTED: 2002/08/0(6.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-43
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/o00 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPIH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 b1
>-24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.009 0.006 0.005 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.016 0.000 0.032 0.029 0.023' 0.028 0.002 0.000 0.000 0.000 0.000 0.008 0.000 0.004 0.000 0.014 0.018 0.000 0.010 0.000 0.000 0.000 0.000 0.001 0.009 0.003 0.067 0.036 0.029 0.026 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.009 0.006 0.030 0.000 0.147 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.024 0.000 0.034 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Q. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0J6 0.047 0.026 0.004 0.000 0.04H 0.046 0.009 0.04H 0.034 0.030 0.038 0.011 0.007 0.0 t.4 0.00 1 0.451 0.040 0.164 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS B GROUND LEVEL STABILITY CLASS B 2114.000 231.920 9.540 9.540 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/0U/06.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-44
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPIIH 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.015 0.022 0.005
- 0. 005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 I0.001 0.001 0.034 0.017 0.000 0.009 0.041 0.018w 0.004 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.011 0.000 0.013 0.008 0.000 0.018 0.000 0.000 0.005 0.003 0.007 0.014 0.000 0.038 0.007 0.023 0.000 0.000 0.023 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.008 0.045 0.016 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0.38 0.015 0.023 0.012 0.001 0.074 0.024 0.015 0.049 0.04 f.
- 0.
(1. 3 0.009 0.003 0.0I'.
O. OHO 0.01, SUBTOTAL 0.000 0.000 0.052 0.124 0.087 0.158 0.022 0.000 0.000
- 0. 44.1 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2114.000 231.920
- 14. 150 9.360 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/08/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-45
SPlIAT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STA13ILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MP11) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24. 5 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.032 0.078 0.047 0.110 0.098 0.019 0.010 0.000 0.000 0.000 0.000 0.009 0.020 0.000 0.009 0.038
- 0. 198 0.180 0.023 0.080 0.175 0.031' 0.027 0.010 0.000 0.004 0.012 0.046 0.053 0.038 0.008 0.018 0.232 0.064 0.022 0.053 0.099 0.000 0.016 0.011 0.012 0.051 0.022 0.744 0.163 0.102 0.019 0.000 0.000 0.048 0.020 0.000 0.000 0.000 0.000 0.053 0.009 0.038
- 0. 115 0.117 0.684 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.019 0.153 0.172 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.043 0.000 q.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 6
TOTAL 0.218 0.175 0.05 0.01H 0.056
- 0. 5 1(
0.342 0.091 0.242
- 0. 3.1.
- 0. (0S!
'0. 10.
- 0. (.3 I
0.093
(.
1119
- 0. 305 0.396 0.818 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS D GROUND LEVEL STABILITY CLASS D 2114.000 231.920 1073.710
- 60. 410 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-46
SPLIT joitrr PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TdTAI.
N NNE NE ENE E
WNW NW NNW
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.004 0.000 0.002 0.001 0.000 0.007 0.000 0.002 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.005 0.015 0.029 0.063 0.157 0.159 0.128 0.178 0.064 0.010 0.008 0.007 0.000 0.000 0.001 0.106 0.049 0.042 0.057 0.242 0.245 0.072 0.114 0.081 0.160 0.000 0.018 0.030 0.004 0.021 0.018 0.124 0.041 0.090 0.027 0.021 0.076 0.020 0.221 0.060 0.124 0.000 0.000 0.000 0.004 0.012 0.037 0.062 0.044 0.043 0.000 0.008 0.000 0.000
- 0. 095 0.178 0.035 0.000 0.029 0.000 0.008 0.025 0.017 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000,
0.000 0.000 0.311
- 0. 13')
- 0. 191 0.114 0.334 0.4U5 0.252 0.559 0.'.52 0..1H5 0.(10 0.056 0.1)37 0.0()7
- 0. 059 0.071 SUBTOTAL 0.000 0.024 0.839
' 1.260 0.858 0.544 0.047 0.000
- 0. 000 3.57 1 TOTAL HOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2114.000 231. 920 741.240 75.500 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY -
12.60 MIS DATE PRINTED: 2002/OH/00, NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-47
SvI.I'I' JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 1b CALM
>=24.5 TOT'AL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.013 0.005 0.010 0.000 0.035 0.027 0.000 0.001 0.009 0.000 0.003 0.000 0.000 0.000 0.108 0.018 0.008 0.034 0.032 0.049 0.042 0.070 0.033 0.073 0.020 0.001 0.000 0.003 0.000 0.000 0.011 0.393 0.049 0.092 0.020 0.017 0.070 0.016 0.014 0.063 0.054 0.000 0.000 0.000 0.002 0.000 0.011 0.024 0.432 0.016 0.016 0.024 0.016 0.009 0.000 0.000 0.069 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.165
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 08H 0.115 0.091 0.070 0.137 0.058
- 0. I1H
- 0. 2H8
- 0. 12H 0.021 0.014)
- 0. (Ut 0.008 0.000 0.011
- 0. (50 1.192 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2114.000 231.920 207.340
- 25. 200 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S DATE PRINTED: 2002/08/06; NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-48
SPI.1T JOINT PIECENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 18.5-24.4 CALM 7.5-12.4 12.5-18.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.003 0.004 0.020 0.024 0.014 0.035 0.037 0.000 0.000 0.006 0.000 0.006 0.000 0.000 0.000 0.149 0.056 0.019 0.017 0.028 0.010 0.006 0.006 0.027 0.027 0.000 0.000 0.000 0.000 0.000 0.003 0.019 0.219 0.039 0.018 0.000 0.011 0.005 0.000 0.000 0.032 0.017 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.0o0 o.000 0.000 0.000 0.000
- 0. 000 0.0(0
- 0. 00) 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 0(0 0.000 0.0(30 0.000 0.000 0.000 o
0.000 0.000 0.000
- 0. 095
- 0. (41
- 0. 021s 0.059 0.03')
0.021) 0.04 1
- 0. 0'Jt.
(0.04 1
- 0. ((0(l
- 0. (0t.
o. 331)1 (3. (3013
(). (0(3 0U.
(31I)
- 0. 4(1 I
- 0. 019 I
0.122 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2114.000 231.920
- 26. 440 10.330 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED:
2002/0H/Ut, NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-49
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY DECEMBER 2002 TABLE 16 JOINT FREQUENCY DISTRIBUTION IN P..RCENT FOR SPLIT LEVEL RELEASES AGROUND LEVEL PORTION)
THIRD QUARTER E2-50
SPIIT JoIlT PEIRCENTAGE FREQUENCIES OF WIND SPEED BY WINI) DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 - SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 18.5-24.4 CALM 7.5-12.4 12.5-18.4
'=24.5 TOI-Al.
N NNE NE ENE E
WNW NW NNTW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.024 0.045 0.057 0.031 0.003 0.000 0.000 0.000 0.000 0.000 0.159 0.000 0.000 0.000 0.000 0.000 0.035 0.118 0.098 0.078 0.062 0.027 0.016 0.000 0.000 0.000 0.000 0.435 0.000 0.000 0.000 0.000 0.003 0.064 0.007 0.000 0.000 0.000 0.009 0.005 0.000 0.000 0.000 0.000 0.087 0.031 0.025 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.064 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. o0o 0.000 0.000 0.000 o
0.000 0.000
- 0. 0HI
- 0. (025
- 0. ((0 0.000 0.00 I
- 0. (,)"
- 0. 14')
- 0. 14 3
- 0. I IS
- 0. 0'3)
- 0. 1 I')
0). 0U I
- 0. 000
- 0. )00
- 0. 0(0
- 0. OOH 0.000 TOTAL TOTAL TOTAL TOTAL IIOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS A GROUND LEVEL STABILITY CLASS A 2156.000 139. 510
- 18. 920 16.060 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S DATE t. NTED: 2002/12/03 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-51
SPI.IT.JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABII.ITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 H)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.006 0.008 0.030 0.000 0.008 0.004 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 I0.000 0.017 0.010 0.003 0.009 0.000 0.007.
0.005 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.006 0.000 0.005 0.028 0.007 0.052 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.007 0.082 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- d. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 007
- 0. 052 0.005 0.000 0.001 0.03C 0.018 O. 03 I
- 0. tl I)
- 0. 00tf
- 0. ()1
- 0.
i)0!'
- 0. Ol)(.
0.017 0.(00 0.012 0.221 0.058
' 0.053 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2156.000 139.510 9.590 4.760 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY -
12.60 H/S INATE PRINTED: 2012/12/)'
NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-52
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 ToUTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.012 0.007 0.011 0.007 0.000 0.000 0.000 0.000 0.000 0.069 0.000 0.003 0.000 0.000 0.000 0.015 0.000 0.000 0.018 0.017 0.000 0.002 0.002 0.000 0.000 0.000 0.058 0.000 0.008 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.006 0.009 0.011 0.009 0.008 0.058 0.020 0.035 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.025 0.007 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.020 0.046 0.000
- 0. 000 0.000 0.022 0.0.12 0.(12 0.026 0.020
- 0. 07 0
(.0(0tj
- 0. 019 0.011
- 0. 0 14 0.016
- 0. 2/19 TOTAL TOTAL TOTAL TOTAL HOURS HIOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2156.000 139.510 31.740 6.020 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/01 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-53
si.ITr JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH2 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>-24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.052 0.078 0.075 0.081 0.096 0.012 0.003 0.001 0.000 0.000 0.000 0.398 0.006 0.015 0.004 0.008 0.034 0.296 0.087 a.028 0.053 0.020 0.008 0.019 0.037 0.008 0.016 0.009
- 0. 649 0.079 0.053 0.014 0.040 0.025 0.184 0.042 0.000 0.000 0.006 0.000 0.006 0.023 0.046 0.032 0.050 0.602 0.046 0.107 0.052 0.038 0.046 0.068 0.000 0.000 0.008 0.034 0.000 0.000 0.014 0.058 0.081 0.068 0.621 0.000 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.000 0.030 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.111
- 0. 19J3 0.070 0.087 0.105
- 0. 600 0.20H
- 0. I0 I
- 0. 142
- 0. 15.
0.020 0.029 0.0'15
- 0. 113 U.14!
- 0. I 27
- 2. 300 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2156.000 139.510 1182.010 49.580 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/OJ NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-54
SPI.I' JOiNr PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 18.5-24.4 CALM 7.5-12.4 12.5-18.4
>=24.5 TOTAL.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.005 0.002 0.000 0.000 0.000 0.001 0.001 0.001 0.011 0.000 0.000 0.000 0.003 0.000 0.029 0.022 0.014 0.014 0.033 0.061 0.099 0.074 0.028 0.073
- 0. 055 0.019 0.000 0.002 0.000 0.003 0.006 0.503 0.108 0.078 0.044 0.060 0.201 0.193 0.023 0.000 0.000 0.000 O. 000f 0.005 0.018 0.000 0.007 0.036 0.772 0.086 0.106 0.083 0.027 0.027 0.023 0.050 0.000 0.045 0.040 0.000 0.000 0.028 0.008 0.000 0.006 0.529 0.015 0.061 0.035 0.000 0.053 0.028
- 0. 000 0.007 0.009 0.035 0.000 0.000 0.015 0.000 0.000 0.000 0.260 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000
- 0. 0(0 0.000 0.000 0.000
- 0. 2J6 0.25H 0.181 0.122 0.342 0.344
- 0. 146 0.031
- 0. 121' 0.1 12
- 0. (I J)
(. 06.1
- 0. OOH 0.(1 I
- 0. 04U
- 2. 093 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2156.000 139.510 717.040
- 45. 130 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED:
2002/12/U0 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-55
SPLIT JtINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/l00 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPHW 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW 1NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.069 0.026 0.010 0.026 0.018 0.005
'0.001 0.001 0.000 0.000 0.000 0.0'00 0.000 0.000 0.000 0.012 0.167 0.121 0.167 0.026 0.034 0.077 0.000 0.000 0.000 0.000 0.000 o.ooi 0.000 0.001 0.003 0.004 0.439 0.007 0.031 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.6000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0(0 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000
- 0. 197 0.226 0.042 0.060
- 0. 095 0.005 0.( 001 0.()01
(}. ((0}{
(. 001
- 0. 0(0 0.((I) 0.003
- 0. (05 0.016 (0.653 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2156.000 139.510 180.080 14.070 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-56
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPHI) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
- .-24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.013 0.006 0.009 0.003 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.037 0.000 0.000 0.019 0.005 0.000 0.000 0.000 0.000 0.000 0.000' 0.000 0.000 0.000 0.000 0.018 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- d. ooo 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.07u 0.021 0.007 0.029 0.00H 0.003
- 0. 0(3 (3.
001) 0.000)
(.000
- 0. 000
- 0. 001
- 0. (3(31)
(3. 0()0
(. 0110
- 0. (ii30 SUBTOTAL 0.000 0.001 0.091
' 0.080 0.008 0.000 0.000 0.000 0.000 0.180 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2156.000 139.510
- 16. 620 3.890 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTEI): 2002/12/10 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-57
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY WUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 17 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)
FOURTH QUARTER E2-58
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24. 5 b
TOTAI.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.023 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012.
0.032 0.012 0.065 0.024 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.017 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.009 0.027
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 P. 000 0.000 0.000 0.000 5.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0o0 0.000 0.000 0.020 0.000 0.00(
- 0. 000 0.000 0.0 12 0.032 0.0 1 0.(HH 0.024
- 0. 0t)0
- 0. (0(
- 0. 000
- 0. 000
- 0. (IS 0.009 0.224 0.029
' 0.151 TOTAL TOTAL TOTAL TOTAL HOURS HOURS IIOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2163.000 267.730 4.850 4.850 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2003/02/().
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-59
SPL1T JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 b>
>=24.5 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.012 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.000 0.015 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.005 0.006 0.000 0.000 0.008 0.037 0.024 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.008 0.000 0.007 0.025 0.079 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.019 0.010 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0)0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001) 1.000 0.000
- 0. 000 0.000 0.000 0.000 TOTAL 0.033
- 0. 01 1 0.006 0.000
- 0. 00)
(0.0(0/
(.0(2 0.011
- 0. 1) i0
- 0. 0tI)t
- 0. (0(
{l(}1.0 1
- 0. 0 1 4 0.00')
- 0. '2i,
- 0. 04 1 0.233 0.030 0.040 TOTAL TOTAL TOTAL TOTAL HOURS HOURS tlOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B 2163.000 267.730 5.040 5.040 HOURS OF GROUND LEVEL STABILITY CLASS B METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-60
SPLIT.I()IIT
'ERCKrNTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 Ml Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WI NI)
DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TdTAI.
N NIIE NE ENE E
WNW NW NiNW SUBTOTAL 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.006 0.008 0.000 0.000 O..000 0.000 0.000 0.000 0.000 0.022 0.001 0.000 0.000 I 0.000 0.000 0.018 0.000 0.043 0.007 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.079 0.000 0.000 0.005 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.006 0.004 0.002 0.018 0.000 0.036 0.032 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.000 0.027 0.028 0.058 0.153 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.051 0.028 0.018 0.127 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000
- 6. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 J. 000 0.05o2
- 0. O()(
0.005
- 0. 000 o.00()
0.01
- 0. (00
- 0. l)(
. ( I (.
- 0. 0110
(. o(0 0.lI.1 0.015
(). Of(0
(. (75 0.076
- 0.
'Ill TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2163.000 267.730 11.780 9.020 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2003/02/10 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-61
sPLlT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABIILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 Ml Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.000 0.000 0.000 0.007 0.026 0.066 0.157 0.111 0.013 0.000 0:000 0.000 0.000 0.000 0.000 0.075 0.046 0.018 0.017
'0.073 0.271 0.076 0.165 0.052 0.016 0.029 0.019 0.023 0.009 0.035 0.036 0.121 0.117 0.035 0.030 0.007 0.304 0.123 0.046 0.008 0.018 0.000 0.036 0.092 0.074 0.050 0.136 0.095 0.114 0.051 0.008 0.017
- 0. 151 0.145 0.008 0.000 0.000 0.000 0.051 0.163 0.189 0.305 0.564 0.000 0.036 0.069 0.010 0.000 0.035 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.049 0.313 0.271 0.084 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.031 0.038 0.000 0.000 0;000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.294
- 0. 313 0.174 0.064 0.104 0.7H7 0.410 0.3H2
- 0. 174 0.047 0.0'9
'0. 10'.
- 0. 32*
- 0. (SIb
- 0. "'3 0.H02 SUBTOTAL 0.000 0.009 0.382
' 0.961 1.196 1.862 0.866 0.069 0.000 5. 34/
TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS D GROUND LEVEL STABILITY CLASS D 2163.000 267.730 1226.710 115. 650 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2003/02/U0 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-62
SPI.IT JOINT PERCEtNTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE OCT 1,
2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.015 0.009 0.008 0.010 0.040 0.055 0.096 0.185 0.176 0.019 0.016 0:003 0.005 0.000 0.003 0.029 0.670 0.101 0.037 0.008 0.030 0.035 0.061 0.120 0.330 0.184 0.074 0.012 0.049 0.023 0.008 0.016 0.086 1.174 0.075 0.043 0.024 0.006 0.000
- 0. 101 0.280 0.444 0.255 0.018 0.000 0.055 0.019 0.014 0.026 0.073 1.432 0.035 0.000 0.000 0.017 0.000 0.071 0.093 0.000 0.269 0.174 0.000 0.008 0.008 0.000 0.016 0.059 0.750 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.012 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.22 7
- 0. 088 0.040 0.063 0.075 0.209)
- 0. 594
- 0. 9i, I
- 0. O8H5
- 0. 285
- 0.028 U. I IS 0.055
- 0. (22
- 0. 0'.
0.259 4. 08 I TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2163.000 267.730 738.. 670 88.280 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE r-, IarED: 2001/02/07' NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-63
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM
>=24.5 TO'TAI N
NNE NE ENE E
WNW NW HNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.002 0.002 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.023 0.058 0.025 0.007 0.003 0.045 0.029 0.051
- 0. 105 0.098 0.015 0.004 0.004 0.001 0.000 0.000 0.033 0.478 0.123 0.038 0.000 0.000 0.026 0.000 0.123 0.220 0.097 0.000 o.ooo 0.000 0.000 0.000 0.000 0.055
- 0. 683 0.000 0.000 0.000 0.000 0.000 0.000 0.069 0.046 0.108 0.000 0.000 0.000 0.000 0.000 0.006 0.008 0.238 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.041 0.127 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.185 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. IH2
- 0. O,1 0.007 0.003 0.071 0.029
- 0. 2tH 0.41.
0.412
- 0. 0(11 0.004 0.004 0.(00
- 0. 000 0.0114 1. f.01 TOTAL TOTAL TOTAL TOTAL HOURS HlOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2163.000 267.730 153. 490
. 34.770 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S DATE PRINTED: 200.1/02/0/
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-64
SPLIT JOltlT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant PART I OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 - DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 b.
CALM
>=24.5 TdTAI.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.010 0.000 0.015 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.057 0.007 0.002 0.005 0.005 0.011 0.012 0.227 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.349 0.033 0.000 0.000 0.000 0.000 0.000 0.000 0.040 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.073 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 8.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 o
0.000 0.000
- 0. 000
- 0. o0u 0.007 0.002 0.005 0.01 I 0.020 0.012
- 0. 2H2 (0. (0(
0. (lI)(
0. (M1)
- 0. (DIII)
- 0. 0(01
- 0. 01)1)
- 0. (M)
- 0. (00t
- 0. 41AH TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2163.000 267.730 22.460 10.120 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S DATE PRINTED: 2003/02/01 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-65
I RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 18 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)
FIRST QUARTER E2-66
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 - MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOi'AI.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 I 0.000 0.000 0.000 0.000 0.000 0.000 0.000, 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.100 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000
- 0. 00(
0.000
- 0. 00()
0.000
- 0. (0O 0.00(
0.00(1
- 0. 01()
0.0011)
- 0. Of)(
(. 0)0(
0.001)
- 0. 01))
- 0. (1()(1
- 0. ()0(
(. 00(
- 0. 000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2108.000 1797.020 25.860 0.000 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-67
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FORt STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 b.
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000
- a. 000 0.000
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000
- 0. ()(O 0.0(0 0.0(o0
- 0. 000 0.000 0.000 0.000 0.000) 0.000
- 0.
0(3(
- 0. ((O 0.000 0.0(30 0.0)00 0.000 0.000
- 0. 000 TOTAL TOTAL TOTAL TOTAL IIOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2108.000 1797.020 8.810 0.000 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/I1.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-68
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<--1.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 18.5-24.4 CALM 7.5-12.4 12.5-18.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
,0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.035 0.000 0.000 0.035 0.000 0,. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000
- 0. 047 0.000 0.000 0.041
.0.0Of(
- 0. 0(1) 0.0 Is 0. nno1
- 0. 000 0.I30 0.000 0.047 TOTAL TOTAL TOTAL TOTAL HOURS HOURS IIOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2108.000 1797.020 13.020
. 2.740 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S DATE PRINTED: 2002/05/1.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-69
Sl'I.IT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 18.5-24.4 CALM 7.5-12.4 12.5-18.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.047 0.047 0.190 0.237 0.190 0.285 0.380
- 0. 190 0.047 0..095 0.047 0.047 0.095 0.047 0.047 0.142 0.285
- 0. 095 0.285 0.095 0.664 0.522 0.190 0.427
- 0. 141 0.237 0.427 0.095 0.190 0.047 0.275 0.591 0.363 0.134 0.094 0.278 0.785 0.047 0.045 0.138 0.227 0.185 0.231 0.452 0.185 0.181 2.684 2.751 0.761 0.211 0.169 0.423 0.719 0.367 0.812
- 1. 106 0.579 0.246 1.208 1.371 1.728 2.007 2.277 0.698 0.039 0.000 0.038 0.426 0.192 0.383 1.578 0.850 0.269
- 0. 191 0.346 1.579
- 2. 196 1.853 0.214 0.000 0.000 0.000 0.000 0.062 0.140 0.268 0.302 0.238 0.000 0.000 0.068 0.603 0.901 0.067 0.008 t).000 0.000 0.000
- 0. 000 0.000 0.021 0.000 0.027 0.012
- 0. 000 0.000 0.000 0.004 0.011 0.003 5.553 4.277
- 1. 496 0.4H7 0.777 1.522 2.759 1.871 3.332
- 2. 960 1.2(,
- 0. 954
- 2. 32h 4.15I
- 5. 306 4.205 SUBTOTAL 0.000 0.047 2.087 3.890 4.210 17.142 12.917 2.863 0.086 43.242 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2108.000 1797.020 1007. 200 911.540 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/05/1l NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-70
SPI.IT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 MI Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTALI N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.142 0.142 0.285 0.047 0.237 0.237 0.095 0.095 0.142 0.095 0.095
- 0. 095 0.047 0.095 0.047 0.095 0.332 0.237
- 0. 190 0.285 0.142 0.190 0.427 0.380 0.237 0.237-0.332 0.285 0.142 0.142 0.332
- 0.
110 0.185 0.223 0.141 0.512 0.225 0.811 0.680 0.727 0.179 0.182
- 0. 184 0.409 0.182 0.414 0.181 1.594 1.154 0.750 0.597 0.298 0.793 1.545 2.361 2.068 0.782 0.502 0.259 0.334 0.126 0.375 1.121 0.154 0.000 0.000 0.079 0.000 0.194 0.653 1.895 2.507 0.966 0.273 0.000 0.000 0.078 0.233 0.390 0.000 0.037 0.000 0.000 0.000 0.000 0.268 0.472 0.789 0.068 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 I.007 0.021 0.042 0.011 0.000 0.000 0.000 0.000 0.000 0.000 2.I19 1.85I 1.353 1.291 I. 142 I. 592 3.71 1
. 95' 6.6.55 2.415 I
. 28!i
- 0. 8.'
I.I23 0.57Th I.259 2.072 SUBTOTAL TOTAL TOTAL TOTAL TOTAL 0.000 0.095 1.992
' 3.985 5.416
- 14. 662 7.422 1.635 0.081 35.2H8 HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS E ELEVATED STABILITY CLASS E 2108.000 1797.020 822. 100 743.870 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15.
NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-71
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 18.5-24.4 CALM 7.5-12.4 12.5-18.4
>=24.5 TO&AL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.095 0.095 0.047 0.000 0.190 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.095 0.047 0.047 0.047 0.095 0.095 0.237 0.142 0.000' 0.000 0.047 0.000 0.000 0.047 0.000 0.045 0.142 0.092 0.045 0.138
- 0. 182 0.094 0.374 0.000 0.047 0.000 0.000 0.000 0.000 0.046 0.165 0.083 0.250 0.042 0.125 0.254 0.371 0.333 0.124 0.043 0.040 0.000 0.000 0.000 0.000 0.126 0.000 0.000 0.000 0.000 0.000 0.000 0.079 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000
- 0. 0oo 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0o.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 C. 000
- .000 I.000 0.000 0.000 0.259 0.222 0.5H1 0.276 0.264 0.439 0.916 0.561 0.782
- 0. I5 0.088 0.00(
0.047 0.000 0.00(
0.259 SUBTOTAL 0.000 0.000 0.569 0.996 1.204 1.954
- 0. 157 0.000 0.000 4.8HI TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2108.000 1797.020 159.840 102.890 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/05/15 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-72
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1,
2002 - MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOtAI.
N NNE NE ENE E
WNW NW NNW SUBTOTAL
- 0. 000 0.000
- 0. 000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.095 0.000 0.190 0.000 0.000 0.047 0.000 0.000 o.o60 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.095 0.000 0.000 0.000 O. 000' 0.000 0.000 0.047 0.000 0.095 0.045 0.046 0.000 0.000 0.000
- 0. 185 0.047 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.368 0.000 0.000 0.000 0.040 0.085
- 0. 127 0.210 0.042 0.000 0.042 0.000 0.000 0.000 0.000 0.000 0.043 0.588 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.039 0.000 0.000 0.000 0.000 0.6000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000
- 0. 045
- 0. 046 0.087 0.040 0.228
- 0. 359 0.541 O.0OH7 0.000 0.0119 0.000
- 0. 0)0
- 0. 00)O 0.047 0.000
- 0. 13H 1.7117 I
0.380 0.332 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS IOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2108.000 1797.020 71.170
- 35. 980 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/05/15 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-73
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY --DECEMBER 2002 A
TABLE 19 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES
- (ELEVATED PORTION)
SECOND QUARTER E2 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<--l.9 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND WIND SPEED(MPH)
DIRECTION CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>24.5 TOTAL N
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0(0 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.01)0 E
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00(
ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00(
SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0o1o SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.(JOO SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.01()
SW 0.000 0.000 0.000 0.00(1 0.000 0.000 0.000 0.000 0.000 0.00()
WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00()
W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0(0 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.(0(
NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0(0 SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 TOTAL HOURS OF VALID OBSERVATIONS 2114.000 TOTAL HOURS OF ELEVATED RELEASES 1882.080 TOTAL HOURS OF STABILITY CLASS A 41.580 TOTAL HOURS OF ELEVATED STABILITY CLASS A 0.000 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DAIF. PRINTED: 2002/oti/o,*
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-75
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 b6
>=24.5 TOTAL.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000' 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Q. 000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. (0O
- 0. ((O
- 0. (((
0.000
- 0. 0((
0.000 0.((0 0.0n0 0.000 0.000 0.000 0.000 I
0.000 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2114. 000 1882.080 9.540 0.000 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 200U08/O6.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-76
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY ClASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 b.
TdTAI.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.043 0.04 3 0.000 0.000 0.000 0.000 0.000 0.128 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.004 0.000
- 0. 000
- 0. 000 0.000
- 0. 000 0.042 0.000
(.000 0.047 0.090
- 0. 04 3 0.0(0
- 0. 0()
0.004 0.000 0.000 0.227 0.000 0.095 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2114.000 1882.080 14.150 4.790 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-77
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 b1
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.000 0.047 0.047 0.284 0.473 0.378 0.662 0.520 0.473 0.142 0.095 0.142 0.047 0.331 0.237 0.142 0.189 0.047 0.237 0.757 0.662 0.757 0.568 0.61S 0.851 0.520 0.378 0.473 0.095 0.228 0.272 0.225 0.185 0.136 0.862 1.139 0.682 0.548 0.496 0.543 0.139 0.318 0.320 0.731 0.364 1.277 1.414 0.703 0.258 0.170 2.324 2.642 1.820 1.257
- 1. 878 1.208 0.125 0.042 0.701 1.551 0.695 1.920 0.965 0.077 0.000 0.000 0.655 1.922 0.735 1.461 1.432 0.193 0.229 0.000 0.000 0.427 0.576 0.414
- 0. 1 10 0.000 0.000 0.000 0.000 0.393 0.111 0.246 0.212 0.00(
0.01 0.000 0.021 0.064 0.121 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.004 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 4.170 3.045 1.241 0.632 0.401
- 4. 124
- 7. 1 19
' 4. 4U07
- 4. 459
- 5. 2411
- 3. 0.19 I. "H I I.022 I.515
- 3. 388 I 898 SUBTOTAL 0.000 0.047 3.453
' 6.859 7.186 18.066
- 10. 593 1.711 0.017 47.933 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2114.000 1882.080 1073.710 1013.300 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/08/06.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-78
S1'LIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 - JUN 30, 2002 WIND DIRECTION CALM WIND SPEED(MPHI) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 18.5-24.4 7.5-12.4 12.5-18.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.095 0.047 0.047 0.095 0.189 0.142 0.047 0.189 0.189 0.237 0.142 0.378 0.284 0.189 0.426 0.284 0.142 3.027 0.189 0.095 0.331 0.378 0.331 0.378 0.520 0.662 0.378 0.331 0.378 0.142 0.426 0.142 0.047 0.237 4.967 0.363 0.687 0.412 0.273 0.591 0.912 0.681 0.637 0.277 0.271 0.316 0.276 0.367 0.045 0.047 0.136 6.294 0.494 1.206 0.832 0.502 0.853 2.277 1.711 1.037
- 1. 118 0.821 0.169 0.254 0.125 0.128 0.371 0.250 12.147 0.348 0.154 0.196 0.194 0.000 0.118 0.888 0.853 0.653 0.733 0.000 0.078 0.000 0.039 0.077 0.039 4.369 0.000 0.000 0.000 0.000 O.
0oo 0.000 0.155 0.359 0.000 0.056 0.000 0.000 0.000 0.000 0.000 0.000 0.570 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.008 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.024 1.441 2.189 1.866 1.536 1. 965 3.733
- 4. 155 3.745
- 2. 669 2.35I
.1.2H9 I.014 1.107 0.780 0.827 0.803 31.492 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2114.000 1882.080 741.240 665.740 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/Ull/Ob NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-79
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5
' TO-AI.
N NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.047 0.095 0.000 0.095 0.095 0.047 0.000 0.000 0.000 0.095 0.047 0.047 0.047 0.237
'0.095 0.047 0.237
- 0. 189 0.142 0.237 0.237, 0.095 0.142 0.284 0.000 0.047 0.045 0.088 0.226 0.408 0.311 0.088 0.184 0.272 0.455 0.091 0.140 0.000 0.047 0.000 0.000 0.000 0.000 0.739 0.377 0.254 0;378 0.288 0.376 0.291 0.168 0.126 0.043 0.000 0.000 0.000 0.087 0.084 0.000 0.000 0.157 0.157 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.092 0.875 0.854 1.055 0.831 0.463
- 0. 844 0.84-7 0.765 0.540 0.514 0.142
- 0. 189 0.284 0.087 0.226 SUBTOTAL 0.000 0.000 0.568
' 2.129 2.355 3.211 0.353 0.000 0.000 8.616 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2114.000 1882.080 207.340 182. 140 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY 12.60 M/S DATE PRINTED: 2002/08/Jt, NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-80
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.095 0.000 0.000
- 0. 000' 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.047 0.000 0.000 0.000 0.092 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.228 0.000 0.041 0.043 0.123 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.250 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.086 0.137 0.123 0.000 0.000 0.183 0.095 0.092 0.047 0.000
- 0. (1(n 0.000 0.001) 0.000 0.000 0.762 I
0.095 0.189 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS G ELEVATED STABILITY CLASS G 2114.000 1882.080 26.440 16.110 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/08/Ub NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-81
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 20 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)
THIRD QUARTER E2-82
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 H)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 - SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 6b
>=24.5 TOT'AL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000' 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.090 0.000 0.000 0.000 0.000 0.000 0.090 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.00(3 (u.
00
- 0. o()
- 0. 00(
0.(00
- 0. 13 1
- 0. 0((
0.00) 0.0(0
- 0. (0O 0.000
- 0. 113 0.000 I0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2156.000 2016. 490 18.920 2.860 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/UI NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-83
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 H)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TdTAI.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.042 0.000 0.000 0.000 0.000 0.085 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.b00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- n. ooo 0.000 o
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0 0 0.000 0.000 0.000 0.182 0.(042 0.0)0 0.000 0.000 0.000 0.224 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2156.000 2016.490 9.590 4.830 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/12/03 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-84
SPI.I' JoIrT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 - SEP 30, 2002 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.046 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.089 0.449 0.045 0.089 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.126 0.000 0.000 0.042 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 9.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 b
TOTAL 0.039 0.0H 0.000 0.000 0.000 0.000 0.045
- 0. 000
- 0. 000 0.30H 0.495
' 0.0(92)
- 0. 177 0.000
- 0. 001) 0.000 SUBTOTAL 0.000 0.000 0.000 1 0.232 0.716 0.207 0.038 0.000 0.000
- 1. I 9 1 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2156.000 2016.490 31.740 25.720 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/12/03.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-85
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<c-0.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 - SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-i.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 b1 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.371 0.186 0.139 0.093 0.186 0.139 0.603 0.835 0.881 1.160 0.881 0.557 0.417 0.278 0.371 0.186 0.417 0.325 0.464 0.093 0.186 0.325 1.020 2.365 1.623 1.855
- 1. 90Z 2.041 0.974 0.510 0.232 0.093 0.183 0.492 0.179 0.000 0.314 0.403 0.945
- 1. 609 1.512 0.937 0.905 0.634 1.035 1.115 0.705 0.229
- 1. 129 1.212 0.487 0.366 0.203 0.851 1.922 2.401 1.718 1.229 0.207 0.000 0.417 0.581 0.942 0.775
- 0. 190 0.457 0.077 0.000 0.037 0.154 1.624 1.093 0.340 0.376 0.000 0.000 0.000 0.038 0.000 0.075 0.000 0.000 0.000 0.000 0.000 0.000 0.404 0.173 0.013 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.291
- 2. 671 1.392 0.551 0.926 1.872 6.519 8.482 6.087 5.587 3.942
' 3.231
- 2. 144
- 2. 523
- 2. 250
- 1. 357 SUBTOTAL 0.000 0.093 7.282
'14.425 11.197 14.440 4.461 0.620 0.007 52.525 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2156.000 2016. 490 1182.010 1132.430 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2002/12/UI NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-86
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED HPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 18.5-24.4 CALM 7.5-12.4 12.5-18.4
>=24.5 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.186 0.000 0.000 0.139 0.000 0.046 0.000 0.139 0.000 0.000 0.000 0.557 0.139 0.417 0.278 0.232 0.464 0.232 0.278 0.510 0.325 0.325 0.557 0.510 0.325 0.139 0.232 0.093 5.056 0.371 0.417 0.881 0.417 0.928 0.788 0.557 0.742 0.788 0.881 0.742 0.742
- 0. 510 0.186 0.232 0.278 9.462 0.313 0.398 0.442 0.578 0.401 0.497 0.675 0.537 0.269 0.130
- 0. 134 0.089 0.134 0.179 0.224 0.312 5.312 0.604 1.661 1.132 0.488 0.283 1.822 0.528 0.592 0.576 0.573 0.082 0.125 0.409 0.081 0.250 0.166 9.372 0.231 0.4 60 0.115 0.000 0.037 0.113 0.037 0.151 0.038 0.000 0.000 0.000 0.000 0.038 0.000 0.000 1.219 0.000 0.029 0.000 0.000 0.029 0.077 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.000 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TdTAL 1.657
- 3. 383 2.849 1.762 2.141 3.715 2.093 2.5132
- 2. 135 1.911) 1.561 1.4(.6 1.516
- 0. 623 0.971 0.849 31.165 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2156.000 2016.490 717.040 671.910 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/0O NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-87
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.04 6 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.139 0.046 0.093 0.046 0.046 0.000 0.093 0.000 0.046 0.046 0.046 0.000 0.000 0.000 0.046 0.139 0.04 6 0.139 0.139 0.046 0.093 0.186 0.232 0.093 0.000 0.186l 0.000 0.000 0.000 0.046 0.139 0.220 0.134 0.135 0.179 0.177 0.046 0.044 0.043 0.000 0.136 0.000 0.045 0.000 0.000 0.046 0.132 0.412 1.173 0.769 0.332 0.500 0.359 0.000 0.000 0.000 0.084 0.000 0.000 0.000 0.000 0.000 0.167 0.000 0.115 0.038 0.000 0.000 0.000 0.000 0.000
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000
- 0. 000 0.000
- 0. 000
- 0. 000 0.000 0.000 0.00(
0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.957 I.608 1.128 0.789 0.769 0.545
- 0. 22'9
- 0. :f.H
(). I 3'l 0.26/
' 0.092
- 0. (0(
- 0. /00 0.093 0.484 SUBTOTAL 0.000 0.093 0.835
' 1.484 1.339 3.795 0.154 0.000 0.000 7.700 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2156.000 2016.490 180.080 166.010 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 H/S DATE PRINTED: 2002/12/10.
NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-88
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL. 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 F.
T&TAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.088 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.161 0.122 0.082 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.161 0.168 0.169 0.045 0.000 0.000 0.046 0.000 0.000
- 0. 0(0 o 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.046 0.046 0.133 0.365 0.000 0.000 0.000 0.590 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2156.000 2016.490
- 16. 620 12.730 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 MIS DATE PRINTED: 2002/12/03' NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-89
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 21 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)
FOURTH QUARTER E2-90
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<--1.9 C/100 H)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 b.
TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000, 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.600 0.000 0.000
- 0. 000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 o
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0o0 0.000 0.000
,0.000 0.000 0.000
- 0. n((
- 0. 0(1(1
- 0. 000 0.00o TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2 163.000 1895.270 4;~850 0.000 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY - 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-91
SPLIT.1(1NT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<--I.7 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTIOtN WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 b.
TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
.0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0..000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000
- 0. 000 0.000
.0.000 0.000 0.000
- 0. 0oo SUBTOTAL 0.000 0.000 0.000 0
O.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2163. 000 1895.270 5.040 0.000 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-92
SPI.IT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<--1.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEEDIMPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4
- 18. 5-24.4
>=24. 5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.035 0.. 000 0.000 0.000 0.035 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.00O 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00(
- 0. 046
- 0. (((
O. 0(f) 0.003 0.000 0.0(0 0.046.
0.12H TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS C ELEVATED STABILITY CLASS C 2163.000 1895.270 11.780 2.760 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2003/02/07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-93
SPLIT.IoiIrr PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABII.ITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1,
2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>-24.5 TqTAL N
NNE NE ENE E
WNW NW NNW
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.04 6 0.04 6 0.046 0.000 0.185 0.139 0.092 0.139 0.231 0.139 0.231 0.416 0.370 0.185 0.601 0.231 0.139 0.185 0.277 0.277 0.416 0.693 0.693 0.231 0.462 0.416 0.509 0.601 0.370 0.509 0.462 0.461 0.509 0.555 0.555 0.832 0.669 0.798 0.671 0.223 0.489 1.024 0.669 0.539 0.133 0.223 0.043 0.136 0.404 0.488 0.713 0.706 1.953 1.460 0.607 0.208 0.164 0.977 1.344 1.212 1.526 0.605 0.686 0.720 1.220 1.510 1.418 2.250 1.137 0.306 0.000 0.075 0.038 0.112 1.274 1.317 0.712 0.263 0.152 0.379 0.600 0.977 1.608 2.067 0.167 0.033 0.043 0.000 0.000 0.012 0.381 0.210 0.249 0.120 0.000 0.000 0.078 0.440 0.267 0.170 0.000 0.000 G. 000 0.000
- 0. 000 0.000 0.042 0.006 0.009 0.028 0.000 0.000 0.000
- 0. 008 0.000 0.000 4.527
- 3. 429 2.10H 0.877
- 1. 385 2.f680 4.449
- 4. 302 3.411 1.933 I.9;44 1.929 2.99S 4.20)9 4.8116
- 6. 301 SUBTOTAL 0.000 0.185 3.837
, 8.276 7.928 17.861 11.017 2.170 0.093 51.367 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS D ELEVATED STABILITY CLASS D 2163.000 1895.270 1226.710 1111.060 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED:
2003/02/07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-94
SPI.IT.JOIINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 f8.5-24.4
>=24.5 b
TqTAI.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.000 0.092 0.000 0.000 0.046 0.000 0.046 0.000 0.046 0.046 0.092 0.139 0.000 0.000 0.139 0.092 0.092 0.277 0.139 0.046 0.277 0.277 0.324 0.370 0.509 0.231 0.092 0.185 0.139 0.185 0.370 0.416 0.185 0.324
- 0.231 0.324 0.416 0.647 0.509 0.462 0.37q 0.370 0.324 0.092 0.185 0.231
- 0.406 0.618 0.404 0.221 0.536 0.571 0.794 0.675 0.496 0.488 0.353 0.315 0.183 0.043 0.266 0.659 1.061 1.216 0.243 0.247 0.245 0.661 1.070 0.676 0.878 0.406 0.247 0.408
- 0. 119 0.043 0.200 1.137 0.228 0.075 0.075 0.037 0.037
- 0. 150 0.564 0.790 0.905 0.112 0.000 0.000 0.153 0.037 0.077 0.227
- 0. 000 0.024 0.027 0.000 0.000 0.012 0.385 0.410 0.254
- 0. 050
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.014 0.008 0.012 0.000 0.000 0.000 0.000 0.000 o
0.000 2.296 2.4H7 I.026 I.I(H 1.188 1.763
- 3. 51rj 3.490 3.420 1.902 1.52!5 1.371 0.963 0.540 0.866 2.41 9 0.000 0.647 3.375 i 5.455 7.028 8.857 3.468 1.160 0.078 30.069 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2163.000 1895.270 738. 670 650. 390 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-95
!;Pi.i*r jOINT' PERrENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
-0.000 0.000 0.092 0.000 0.046 0.000 0.092 0.139 0.046 0.092 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.092 0.000 0.000 0.000 0.092 0.139 0.324 0.277 0.324 0.185
- o. ood 0.092 0.000 0.046 0.000 0.046 0.087 0.224 0.000 0.087 0.046 0.491 0.088 0.228 0.178 0.000 0.000 0.045 0.000 0.000 0.000 0.413 0.279 0.126 0.082 0.000 0.207 0.248 0.000 0.041 0.042 0.000 0.000 0.000 0.000 0.000 0.280 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.506 0.551 0.350 0.128 0.087 0.438 1.04H 0.45H 0.63')
0.5H(I
- 0. I8H 0.0(0 0.137 0.046
- 0. 046
- 0. 2H(
SUBTOTAL 0.000 0.000 0.601 1 1.618 1.519 1.718 0.000 0.032
- 0. 000
- 5. 41'9 TOTAL TOTAL TOTAL TOTAL HOURS 11OURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2163.000 1895.270 153. 490 118.720 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -
12.60 M/S DATE PRINTED: 2003/02/07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-96
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4
- 18. 5-24.4
>=24.5 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 O
0.000 0.000 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.000 0.131 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.177 0.123 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.162 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL l
0.123 0.039 0.131 0.000 0.000 0.046 0.04h 0.092 0.092 0.0(0 0.000
- 0. 000 0.000
- 0. 000 0.000
- 0. 0(0 0.571 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2163.000 1895.270
- 22. 4 60
- 12. 340 METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-97
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -. DECEMBER 2002 TABLE 22 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FIRST QUARTER E2-98
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-I.9 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 I 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>-24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000.
0.000 TOTAL 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.0(0 0.0(0 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.(000 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 0
0 2120 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED =
0.00 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-99
JoINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 H)
Browns Ferry Nuclear Plant JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>-24.5 TOTAL
_ 6 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
.0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 O. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 00 0.000 0.000 0.(00 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS IOURS HOURS IIOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 0
0 2120 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 69.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/1S MEAN WIND SPEED =
0.00 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 00
.JOIIIT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL b,1~
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 I 0.000 0.047 0.000 0.000 0.000 0.000
- 0. OOQ
- 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.o00 0.000 0.000 0.000 0.000 0.000 0.000 0.047
.0.000 0.000 0.047 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 o
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.00n 0.142 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 3
3 2120 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002t05/15 MEAN WIND SPEED = 10.90 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-101
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<-0.5 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.094 0.047 0.094 0.094
- 0. 142 0.094 0.236 0.283 0.142 0.236 0.094 0.094 0.047 0.047 0.000 1.745 0.189 0.047 0.142 0.047 0.142 0.189 0.377 0.377 0.142 0.330 0.236 0.142 0.142 0.189 0.094 0.047 2.830 0.236 0.377 0.236 0.047 0.142 0.236 0.519 0.283 0.047 0.094 0.047 0.236 0.425 0.283 0.189 0.142 3.538 2.500 2.783 0.896 0.236 0.330 0.660 0.425 0.377 0.660 0.708 0.472 0.377 0.991 1.509 0.849 1.509 3.208 1.557 0.236 0.094 0.094 0.330 0.189 0.519 1.840 1.462 0.566 0.236 0.708
- 2. 170 2.170 2.689 0.708 0.142 0.000 0.000 0.047 0.330 0.236 0.613 0.896 0.566 0.142 0.236 0.377 1.415 1.934 0.566 8.208
- 0. 189 0.000 0.000
.0.000 0.000 0.047 0.236 0.000 0.283 0.142 0.000 0.000 0.094 0.566 0.236 0.142 1.934 7.075 5.000 1.557 0.519 0.849 1.934 2.075 2.406 4.198 3.443 X. ae98
- 1. 321 2.83(0
- 6. 179 5.519 5.094 51.6cq 15.283 18.066 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2132 1100 1096 2120 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED = 13.42 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-102
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<- 1.5 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 -
MAR 31, 2002 WIND DIRECTION WIND SPEED(MP11) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>-24.5 TOTAL.
b, N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.047 0.236 0.142 0.094 0.142 0.189 0.000 0.047 0.142 0.094 0.047 0.047 0.000 0.047 0.047 1.415 0.047 0.142 0.142 0.236 0.094 0.094 0.047 0.142 0.189 0.142 0.189 0.094 0.09*
0.094 0.142 0.047 1.934 0.094 0.189 0.142 0.094 0.142 0.189 0.283 0.142 0.283 0.377 0.189 0.189 0.000 0.094 0.330 0.236 2.972 0.896 0.613 0.472 0.660 0.472 0.472 1.038 1.462 2.594 0.991 0.566 0.283 0.613 0.472 0.189 0.472 12.264 1.321 1.038 0.377 0.425 0.142 0.236 0.755 2.453 4.340 1.462 0.708 0.283 0.330 0.189 0.377 0.849 15.283 0.047 0.094 0.047 0.047 0.000 0.142 0.472 1.509 2.075 0.519 0.047 0.000 0.000 0.000 0.142 0.094 5.236 0.000 0.000 0.000 9.000 0.000 0.000 0.330 0.566 0.896 0.283 0.000 0.000 3.000 0.000 0.000 0.000 2.500 2.123 1.415 1.604 0.943 1.274
- 3. II1 6.274
- 10. 425
- 3. 9 1' 1.792 0.896 1.(a85
' 0.H49 I
. 22(I I. 74) 2.075
- 41. 179 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 881 873 2120 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED -
13.54 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-103
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<- 4.0 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 - MAR 31, 2002 WI ND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL b,
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.189 0.000 0.000 0.047 0.047 0.094 0.000 0.047 0.047 0.000 0.047 0.000 0.00, 0.000 0.000 0.000 0.000 0.330 0.047 0.000 0.047 0.000 0.142 0.000 0.094 0.047 0.094 0.094 0.047 0.000 0.047 0.000 0.000 0.000 0.660 0.094 0.094
- 0. 189 0.189 0.000 0.094 0.425 0.236 0.425 0.425 0.000 0.000 0.000 0.000 0.000 0.047 2.217 0.094 0.142 0.236 0.047 0.047 0.047
- 0. 142 0.472 0.094 0.142 0.094 0.000 0.000 0.000 0.000 0.047 1.604 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0; 000 0.047 0.189 0.000 0.000 0.000
'0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000.
0.000 0.23f6 0.23f6 0.613 0.283 0.330 0.142 0.802 0.802 0.708 0.708 0.142 0.000 0.047
- 0. 00()
0.000 0.142 5.189 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 110 110 2120 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/1'i MEAN WIND SPEED -
10.97 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-104
JOIIIT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant JAN 1, 2002 -
MAR 31, 2002 WIND
)IRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW
- UBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.094 0.000 0.000 0.000 O. 000 0.000 0.000 0.000
- 0. 142 0.000 0.000 0.000 0.094 0.047 0.047 0.047 0.000 0.047 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.377 0.000 0.094 0.000 0.000 0.000 0.142 0.377 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.755 0.000 0.094 0.000 0.047 0.047 0.047 0.094 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.425 0.000 0.000 0.000 0.000 0.000 0.000 0.047
- 0. 000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.189 0.000 0.142 0.094 0.236 0.566 0.142
- 0. I09
- 0. 109 0.000 0.00n 0.000 0.000 0.00n 0.047 1.792 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS 11OURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 38 38 2120 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/1S MEAN WIND SPEED -
10.36 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-105
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 23 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES SECOND QUARTER E2-106-
JIoNT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL b
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 9.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00(
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. ((O
- 0. (000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 0
0 2 134 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/0/0f MEAN WIND SPEED -
0.00 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-107
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 - JUN 30, 2002 WI ND DIRECTION WIND SPEED(MPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N
NNE NE ENE E
WNW NW NNW SUBTdTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000
- o. ood 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.o00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000.
0.000 U
TOTAL.
- 0. 000
- 0. 0(0
- 0. 000 0.000 0.000
- 0. 000 0.00O
- 0. 0(0 0.000
- 0. (0(
- 0. 000
- 0. 0oo 0.(00
- 0. (0) 0.000 0.000 0.00(1 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 0
0 2134 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =
0.00 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-108
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.141 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
-0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000
- 0. 00(1 0.000 0.000 0.047 0.000 0.000 0.047 0.047 0.094 0.0(n0 0.0(0
- 0.047 0.000 0.000 0.281 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS IIOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 6
6 2134 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/0#.
MEAN WIND SPEED - 12.33 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-109
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL b-N NNE NE ENE E
WNW NW NNW SUBTOTAL
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.000 0.047 0.047 0.094 0.094 0.234 0.375 0.187 0.515 0.375 0.375 0.047 0.047 0.000 2.484 0.141 0.187 0.187 0.141 0.000 0.141 0.422 0.515 0.328 0.656 0.515 0.703 0.42Z 0.515
- 0. 469 0.047 5.389 0.281 0.234 0.141 0.187 0.000 0.515 0.890 0.703 0.422 0.281 0.234 0.281 0.422 0.515 0.609 0.187 5.904 0.984
- 1. 687 0.750 0.375 0.281 3.140 2.156 1.687 1.359 1.640 0.984 0.141 0.281 0.937 1.500 0.609 2.015 1.265 0.328 0.000 0.047 1.781 1.968 1.218 1.453 1.781 1.312 0.141 0.047 0.187 0.562 0.656 1.172 0.281 0.000 0.000 0.000 0.234 1.500 0.422 0.750 1.125 0.375 0.281 0.000 0.000 0.094 0.469 6.701 0.047 0.000 0.000 0.000 0.000
- 0. 000 0.187 0.281 0.141 0.187 0.000 0.094 0.000 0.047 0.094 0.047 4.639 3.702
- 1. 406 0.750 0.375 5.904 7.216 5.06f1 4.827 5.H5R 3.936 2.015 1.54 6 2.24')
- 3. 374 2.0(.2 54.920 18.510 14.761 1.125 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS tlOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 1180 1172 2134 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED -
11.82 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-110
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nti.lear Plant APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL.
N NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.141 0.000 0.141 0.187 0.234 0.000 0.234 0.328 0.141 0.187 0.234 0.094 0.047 0.000 0.094 0.000 0.094 0.234 0.281 0.234 0.094 0.141 0.094 0.234 0.234 0.375 0.094 0.047 0.234 0.328 0.234 0.094 0.281 0.281 0.422 0.422 0.234 0.375 0.234 0.094 0.187 0.281 0.141 0.141 0.187 0.890 0.843 0.609 0.656 1.359 1.453
- 1. 687 1.500 0.515 0.469 0.515 0.281 0.328 0.141 0.281 0.609 0.843 0.656 0.328 0.234 1.734 1.828 0.984 1.500
- 1. 172 0.281 0.187 0.141 0.047 0.234 0.234 0.281 0.141 0.234 0.187 0.000 0.000 0.328 0.562 0.422 0.656 0.047 0.000 0.000 0.000 0.047 0.047 0.000
- 0. 000 0.000
,0.000 0.000 0.000 0.141 0.422 0.094 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 I.359 2.296
- 2. 062 1.218 1.406
- 3. 655 4.592
- 4. 499 4.077
- 2. 905 I. 4U06 l. 359 1.031 1.218 0.917 0.841 SUBTOTAL 0.000 0.281 1.968 2.296 3.983 11.715
- 11. 012 2.952 0.656 34.864 TOTAL HOURS TOTAL IIOURS TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 747 744 2134 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/0H/06 MEAN WIND SPEED -
11.68 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-111
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 - JUN 30, 2002 WIND DIRECTION WIND SPEED(MPII) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 -18.5-24.4
>=24.5,
TOTAL N
NNE NE ENE E
WNW NW NNW
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.047 0.000 0.000 0.047 0.047 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.047 0.000 0.094 0.000 0.047 0.047 0.000 0.094 0.094 0.047 0.000 0.094 0.000 0.000 0.000 0.047 0.000 0.047 0.094 0.234 0.000 0.141 0.047 0.000 0.000 0.141 0.000 0.047 0.047 0.187 0.328 0.281 0.469 0.469 0.375 0.187 0.422 0.234 0.422 0.094 0.047 0.187 0.000 0.047 0.000 0.422 0.234 0.375 0.141 0.234 0.187 0.515 0.562 0.187 0.234 0.000 0.000 0.000 0.047 0.047 0.000 0.094 0.141 0.141 0.000 0..000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 o
0.000 0.094 0.703 0.750 0.937 0.703 0.75(
0.750 0.9H14 I
. 0718
- 0. (.5St 0.701 0.I1H)
- 0. IU7 0..375 0).047 0.214 SUBTOTAL 0.000 0.000 0.328 1 0.656 0.797 3.796 3.187 0.375 0.000 9.I. t TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 195 195 2134 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/0; MEAN WIND SPEED - 11.21 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-112
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant APR 1, 2002 -
JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.000 0.041 0.000 0.000 0.000 0.000 0.141 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.094 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.234 0.000 0.047 0.094 0.047.
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.187 0.000 0.000 0.000 0.000 0.141 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 l.000 0.000
- p. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000-0.000 TOTAL F.
- 0. 0(1 0.094 0.094 0.047 0.141
- 0. (10()
0.0(0
- 0. 04O 0.141
- 0. 094
- 0. 094
- 0. 047 0. (00
(. IM)(
0.070
- 0. 797?
TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 17 17 2134 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/10/81 MEAN WIND SPEED -
8.85 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-113
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 TABLE 24 JOINT FRLQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES THIRD QUARTER E2-114
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-I.9 C/100 M)
Browns Ferry Nuclear Plant JUL 1, 2002 - SEP 30, 2002 WIND
)IRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5 N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 o.ono 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
,. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000
- 0. 000 0.000 0.000 0.000 TOTAL.
0.000
- 0. (0t()
- 0. 000
- 0. 00 0.00(
0.000 0.000 0.0(0 0.000
- 0. 000
- 0. I000)
O. 0(}0
- 0. 0t0
- 0. 000
- 0. Ii¶9 SUBTOTAL 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS HOURS CALM 2189 3
3 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/1J.
MEAN WIND SPEED =
9.70 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-115
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B 1-1.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant JUL 1,
2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPIH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.185 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 p.000
.0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 00)0 0.000
- 0. 000 0.000
- 0. ((O 0.000 0.(00 0.000 0.0(00 0.000 0.2 32 0.000
- 0. 0(O
- 0. 00n 0.00(
0.000 SUBTOTAL 0.000 0.000 0.000 0.046 0.000 0.185 0.000 0.000 0.000 0.232 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 5
S 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/10 MEAN WIND SPEED =
8.12 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-116
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant JUL 1, 2002 -
SEP 30, 2002 WI ND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5 TOTAL b
l N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.139 0.046 0.093 0.000 0.000 0.000 0.371 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.278 0.325 0.046 0.093 0.000 0.000 0.000 0.742 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.001) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
-0.000 0.00C 0.000 0.000
- 0. 000
- 9. 000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093
- 0. Ot)
- 0.
00o 0.000 0.000 0.000 0.046 0.000
- 0. O)1t 0.3.11
- 0. 4 h4 0.091
- 0. IlsS U. (1))
- 0. 000
- 0. (300 I.2 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 27 27 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/ot.
MEAN WIND SPEED =
8.55 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-117
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5 b
TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.325 0.185 0.093 0.232 0.139 0.093 0.371.
0.742 0.788 1.020 0.834 0.371 0.232 0.417 0.185 0.185 0.556 0.232 0.185 0.232 0.093 0.325 1.020 1.298 1.344 0.834 1.113 1.623 0.742 0.464 0.232 0.093 0.139 0.464 0.232 0.000 0.139 0.278 1.066 1.669 0.834 0.881 0.742 1.113 1.205 0.927 0.464 0.232 0.742 0.974 0.278 0.185 0.278 1.066 1.854 2.411 2.364 1.808 1.484 0.417 0.881 1.113 1.205 0.603 0.974 0.881 0.371 0.325 0.139 0.881 2.086 1.391 0.649 0.834 0.046 0.000 0.093 0.000 0.093 0.325 0.000 0.046 0.000 0.000 0.046 0.046 1.066 0.649 0.139 0.232 0.000 0.000 0.000
-0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.046 0.093 0.04 6 0.000 0.000 0.000 0.000 0.000 0.000
- 2. 735 2.782 1.159 0.974 0.834 2.689 7.603 H. 20ta 6.25')
- 5. 6Sb 4.219 3.521
- 3. 153 2.921 2.1779 1.530 SUBTOTAL 0.000 0.093 6.212 f10.385 10.385 17.663 9.087 2.272 0.325 56.421 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 1233 1217 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRIINTED: 2002/12/US HEAN WIND SPEED -
8.71 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-118
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5,
TOTAL.
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.139 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.278 0.185 0.139 0.139 0.046 0.232 0.232 0.371 0.139 0.093 0.371 0.232 0.232 0.232 0.046 0.139 0.139 2.967 0.371 0.093 0.232 0.185 0.325 0.371 0.927 0.510 0.464 0.556 0.649 0.649 0.742 0.139 0.139 0.278 6.630 0.139 0.325 0.371 0.325 0.046 0.325 0.649 0.603 0.556 0.325 0.278 0.278 0.464 0.232 0.232 0.139 5.285 0.417 0.742 0.742 0.834 0.371 1.113 0.974 0.927 0.603 0.464 0.556 0.232 0.417 0.139 0.510 0.232 9.272 0.695 1.484 1.020 0.556 0.185 0.974 0.788 0.139 0.417 0.603 0.046 0.046 0.139 0.232 0.046 0.046 7.418 0.046 0.371 0.278 0.000 0.000 0.093 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.881
- 0. 0(0 0.000 0.000
- 0. 000 0.1H5 0.093 0.046 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000
- 0. 000 0.000 0.325 1.854 3.151 2.782 1.947 1.344 3.199 3.848
- 2. 3b4 2.272
- 2. 3 1l I
. 7.2 1. 4 JIl I. 99i' 0.788 I.
15')
0.t1J4 3 J. 055 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 726 713 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/03.
MEAN WIND SPEED -
9.05 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 19
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( l.5c DELTA T<= 4.0 C/100 MI Browns Ferry Nuclear Plant JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4
,18. 5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.093 0.046 0.046 0.000 0.046 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.325 0.093 0.139 0.046 0.046 0.046 0.000 0.093 0.046 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.046 0.695 0.000 0.139 0.000 0.000 0.185 0.185 0.093 0.185 0.139 0.093 0.000 0.000 0.000 0.000 0.000 0.046 1.066 0.371 0.232 0.278 0.185 0.417 0.278 0.093 0.093 0.139 0.139 0.093 0.000 0.000 0.046 0.093 0.000.
2.457 0.371 0.927 0.556 0.417 0.093 0.371 0.139 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.093 3.060 0.000 0.185 0.325 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0:000 0.000 0.556 0.000
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.8 N 1
. h2 3 1.205 0.788 0.788 0.927
- 0. 4 17 0.41.1
- 0. 325 0.325
- 0. IIS 0.041,
- 0. 046
- 0. 041;
- 0. 09U
- 0. IH5 8.252 TOTAL TOTAL TOTAL TOTAL TOTAL IIOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 180 178 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/UJ MEAN WIND SPEED -
11.12 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-120
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant JUL 1, 2002 -
SEP 30, 2002 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5,
TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046
- 0. 185 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046
- 0. 139 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.093 0.093 0.139 0.046 0.185 0.000 0.046 0.000 0.000 0.000 0.00(
0.0(0 0.
U(O 0.000 0.000 0.04b SUBTOTAL 0.000 0.000 0.046 0.000 0.000 0.232 0.232 0.139 0.000
- 0. 649 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OF VALID WIND DIRECTION-WIND SPEED-STABILITY CALM CLASS G OBSERVATIONS 2189 15 14 2157 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/lZ/UI MEAN WIND SPEED -
13.66 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 21
RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -
DECEMBER 2002 A
TABLE 25 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FOURTH QUARTER E2-122
JOINT1' PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPHI) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5 TOTAL k6 N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 p.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.0(0
- 0. O(0 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.00(
0.000
- 0. 00()
- 0. 001)
- 0. (1)(
0.00(
- 0. Ou0 0.000
- 0. 000 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 0
0 2176 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED -
0.00 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-123
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9' DELTA T<=-1.7 C/100 H)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 *18.5-24.4
>=24.5 TOTAL N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- o. ood 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Q.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 00)
- 0. 00o
- 0. 0o0 0.000
- 0. 000
- 0. 00(3 0.000 0.00o
- 0. 00o 0.0(3(
0.001)
- 0. 00(
- 0. 000 0.00(3
- 0. 0(0
- 0. 01)
SUBTOTAL 0.000 0.000 0.000 0
O.000 0.000 0.000 0.000 0.000 0.000
(. 00(
TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 0
0 2176 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 200:1/02/01 MEAN WIND SPEED -
0.00 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-124
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL b
N NNE NE ENE E
WNW NW NNW SUBTOTAL
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 I 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0
O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 00(
- 0. 000
- 0. 00o 0.000
- 0. 000
- o.
0on
- 0. 000
- 0. 0()(
- 0. 04i.
- 0. 0(11)
- 0.
11((1
.0.(4f.
- 0. 0)0
- 0. 00)l 0.04t.
0.1 3S TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 3
3 2176 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED -
11.13 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-125
JoIurr PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<--0.5 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>=24.5
- TOTAL, N
NNE NE ENE E
WNW NW NNW 0.000 0.000.
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.138 0.046 0.138 0.000 0.046 0.230 0.414 0.230 0.230 0.184 0.276 0.138 0.276 0.322 0.184 0.276 0.506 0.276 0.046 0.368 0.276 0.230 0.551 0.368 0.092 0.873 0.368 0.551 0.414 0.551 0.506 0.597 0.551 0.643 0.138 0.276 0.689 0.506 0.597 0.092 0.092 0.184 0.230 0.368 0.322 0.643 0.368 2.022
- 1. 654 0.827 0.368 0.643 1.425
- 1. 103 1.241 1.011 0.597 0.551 0.276 1.057 1.700 1.149 2.390 1.471 0.827 0.368 0.092 0.138 0.551 1.563 1.379 1.379 0.460 0.643 0.919 0.873 1.057 1.700 2.619 0.414 0.046 0.000 0.092 0.046 0.046 1.149 0.827 0.551 0.276 0.046 0.230 0.735 1.011 0.827 1.057 0.000
- 0. 000 p.092 0.000 0.000 0.092 0.689 0.460 0.276 0.368 0.00(
0.000 0.130
- 0. 138 0.092 0.000 4.8'5 3.722 2.298 0.873 1.471
- 3. 1'S 5.4 t.9
- 5. 4ti
- 3. 9Ut, 2.114 2.4H
- 2. 219u 3.0,t) 4.'317
- 5. 11
- 7. It.
SUBTOTAL 0.000 0.138 2.895 6.250 6.296 18.015 16.039 7.353 2.344
- 59. 3.:9 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 1296 1291 2176 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/0U3/01 MEAN WIND SPEED - 12.12 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-126
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<- 1.5 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>-24.5,
TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.046 0.046 0.000 0.000 0.092 0.092 0.046 0.092 0.000 0.046 0.04 6 0.046 0.000 0.046 0.092 0.046 0.184 0.046 0.138 0.322 0.322 0.230 0.138 0.276 0.046 0.046 0.138 0.092 0.092 0.276 0.184 0.138 0.046 0.046
- 0.138 0.138 0.092 0.322 0.092 0.276 0.046 0.184 0.276 0.230 0.092 0.138 0.184 0.046 0.230 0.184 0.138 0.230 0.368 0.460 0.460 0.276 0.276 0.138
- 0. 138 0.092 0.138 1.057 1.149 0.873 0.322 0.506 0.827 1.195
- 1. 195 0.597 0.827 0.643 0.551 0.230 0.138 0.368 0.506 0.965 0.965 0.322 0.138 0.230 0.368 0.368 1.057 1.746 0.414 0.414 0.551 0.230 0.000 0.276 0.735 0.046 0.046 0.138 0.000 0.046
- 0. 138 0.781 0.9i9 0.919 0.04 6 0.046 0.046 0.092 0.046 0.000 0.092
- 0. 000 0.046 p.046 0.046 0.000 0.046 0.781 0.735 0.184 0.138 0.000 0.000 0.000 0.000 0.000
- 0. 000 2.528 2.757
- 1. 654 1.011
- 1. 103 1.792 3.814 4.779 4.550
- 2. 16(X 2.0 L2I I.517
(. 's,5 0.fllI
- 1. 101 I
. b54 0.000 0.689 2.252 2.574 3.493 10.983 8.778 3.401 2.022
- 34. 191 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 749 744 2176 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07.
MEAN WIND SPEED -
12.00 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-127
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T< 4.0 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4.18.5-24.4
>-24.5 TOTAL b
N NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.04 6 0.092 0.092 0.000 0.000 0.000 0.000 0.138 0.138 0.046 0.000 0.000 0.046 0.000 0.597 0.000 0.092 0.046 0.000 0.000 0.000 0.046 0.046 0.000 0.092 0.092 0.046 0.000 0.046 0.000 0.000 0.506 0.000 0.000 0.046 0.046 0.000 0.046 0.092 0.138 0.230
- 0. 184 0.138 0.184 0.046 0.000 0.000 0.000 1.149 0.184 0.276 0.000 0.092 0.000 0.000 0.368 0.322 0.092 0.138 0.322 0.184
- 0. 138 0.000 0.000 0.000 2.114 0.092 0.276 0.138 0.092 0.000 0.000 0.000 0.046 0.138 0.092 0.000 0.000 0.000 0.000 0.000 0.322 1.195 0.000 0.092 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.184
- 0. 000
- 0. 000 p.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.276 0.735 0.322 0.322 0.092 0.046 0.S51 0.551
- 0. 4t.O 0.643 0.6(")
0.4 0 0.1184 0.046 0.046 0.322 5.744 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WI1ii. DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 125 125 2176 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07.
MEAN WIND SPEED -
9.34 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-128
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant OCT 1, 2002 -
DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4
.18.5-24.4
>=24. 5 TOTAL N
NNE NE ENE E
WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.046 0.046 0.000 0.000 0.092 0.000 0.000 0.000 0.000 I0.000 0.000 0.000 0.000 0.046 0.000 0.000
- 0. 000a 0.000 0.000 0.000 0.000 0.046 1
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.000 0.000 0.000 0.000 0.000 0.138 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.138
- 0. 000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.184 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 O.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.13H
- 0. 01) 0.04 6 0.092 0.046
- 0. 000 0.1)0(1
- 0. 00o
- 0. 04*,
- 0. 04.
(. 09.'
- 0. (()(
'0. 04
.t 0.)4 t.
- 0. (00
- 0. 00)
- 1.
')
TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 13 13 2176 0
METEOROLOGICAL FACILITY:
Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/0(2/01.
MEAN WIND SPEED -
9.95 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-129
ENCLOSURE 3 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)
UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JANUARY THROUGH DECEMBER 2002 E3-1
ENCLOSURE 3 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)
UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT 2002 E3 -1
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 Regulatory and BFN ODCM Limits A.
Fission and Activation Gases in Gaseous Effluent:
The release of fission and activation gases is regulated by the dose limits of 10 CFR 50 Appendix I and BFN Offsite Dose Calculation Manual (ODCM). The air dose to areas at and beyond the site boundary due to noble gases released in gaseous effluents per unit, shall be limited during any calendar quarter to < 5 millirad (mrad) for gamma radiation and < 10 mrad for beta radiation; and during any calendar year to < 10 mrad for gamma radiation and < 20 mrad for beta radiation.
B.
Iodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents.
The release of iodines and particulates in gaseous effluent is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The dose to a member of the public from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives greater than eight days in gaseous effluent released per unit to areas at and beyond the site boundary shall be limited to any organ during any calendar quarter to < 7.5 millirem (mrem), and during any calendar year to < 15 mrem.
C.
Liquid Effluents The release of radioactive liquid effluents is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas shall be limited during any calendar quarter to < 1.5 mrem to the total body and <5 mrem to any organ and during any calendar year to < 3 mrem to the total body and < 10 mrem to any organ.
II.
Limitation on Dose Rate A.
Fission and Activation Gases in Gaseous Effluent:
- 1. The instantaneous release rate of fission and activation gases is based on the dose rate limits of 10 CFR 20.1301 and the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary due to noble gases released in gaseous effluents from the site shall be limited to
< 500 mrem per year to the total body and < 3000 mrem per year to the skin.
E3 -2
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 II.
Limitations on Dose Rate (Continued)
B.
Iodines and Particulates with Half-Lives Greater than Eight Days in gaseous effluents.
- 1.
The instantaneous release rate of particulates and iodines is regulated by the dose rate limits of the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary, due to I-131, I-133,11-3 and particulates with greater than eight days half-lives released in gaseous effluents from the site, shall be limited to < 1500 mrem per year to any organ.
- 2.
The BFN ODCM Section 7.3 determines the maximum particulate and iodine dose rates.
C.
Liquid Effluents
- 1. The concentration of radionuclides in liquid effluents released at any time from the site to unrestricted areas shall be limited to the concentrations specified in 10 CFR 20.1001 -
20.2402, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases.
- 2. For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 pCi per milliliter (ml) total activity.
mII.
Measurements and Approximations of Total Radioactivity A.
Fission and Activation Gases:
- 1. Noble gases in the building vent and stack (elevated) gaseous effluents are continuously monitored. The flow rate of the stack is continuously monitored and the building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans. The vent flow is calculated for each release. Gas grab samples of the stack are taken and analyzed weekly. Gas grab samples of in-service vents are taken and analyzed monthly. The specific noble gas activity concentrations and total volume of the gases are used to calculate the total curies of noble gases released.
- 2. The tritium concentration is determined by the analysis of a monthly grab sample for each release point.
E3-3
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 mI.
Measurements and Approximations of Total Radioactivity (continued)
B.
Iodines and Particulates I.
lodines and particulates are continuously sampled on impregnated charcoal filters and particulate filters, respectively. The charcoal and particulate samples are replaced at least weekly and analyzed to determine specific activity concentrations. The specific activity concentrations and vent flow rate data are used weekly to verify that release rate limits were not exceeded. The specific activity concentrations and total volume of gaseous effluent are used on a monthly basis to determine the total curies of each particulate and iodine released during the month.
- 2.
The gross alpha concentration is determined by analysis of a monthly particulate filter composite sample and strontium -89 and -90 are determined by analysis of a quarterly particulate filter composite sample for each release point.
C.
Liquid Effluents
- 1.
The gamma ray emitting radionuclide concentrations are determined for each batch by gamma ray spectroscopy analysis of a grab sample. The allowable release rate is calculated for each batch based upon the known dilution flow. The flow rate of the liquid effluent is continuously monitored and the total volume released in each batch is determined. The total gamma activity released in each batch is determined by multiplying the radionuclide concentrations by the total volume discharged. The total gamma activity released during the month is then determined by summing the gamma activity content of each batch discharged during the month.
- 2.
The gross alpha and tritium concentrations are measured on a monthly composite sample.
The strontium -89 and -90 and iron -55 are measured on a quarterly composite sample.
D.
The Radioactive Gaseous and Liquid Waste Monitoring Sampling and Analysis Program is specified in ODCM Sections 1/2.2.1 and 1/2.2.2.
E3-4
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION 2002 IV.
Batch Ouarter Ouarter Ouarter Ouarter 1
2 3
4 A. Liquid Units 1.
2.
3.
4.
5.
6.
Number of batches released Each Total time for batches released Minutes Maximum time period for a batch release Minutes Average time period for a batch release Minutes Minimum time period for a batch release Minutes Average stream flow during period of release into a flowing stream Cubic feet per second 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 B. Gaseous None C. Abnormal/Unplanned Releases*
Type Liquid Gaseous Number of Releases One None Total Activity Releases (Curies) 4.71E-0I None
- An explanation of any liquid or gaseous abnormal/unexplained release shall be documented in the summary.
E3 -5
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES YEAR 2002 A. Fission and Activation Products (Does not include tritium, gases, Alpha)
- 1. Total Release
- 2. Average Diluted Concentration Released During Period
- 3. Percent of Applicable Limit B. Tritium
- 1. Total Releases
- 2. Average Diluted Concentration Released During Period
- 3. Percent of Applicable Limit C. Dissolved and Entrained Noble Gases
- 1. Total Releases
- 2. Average Diluted Concentration Released During Period
- 3. Percent of Applicable Limit D. Gross Alpha Radioactivity
- 1. Total Releases
- 2. Average Diluted Concentration Released During Period E. Volume of Liquid Waste to Discharge Canal (Prior to dilution)
F. Volume of Dilution Water for Period G. Total CCW gi Units Ouarter I
Curies NR*
Ouarter 2
Ouarter Ouarter Error 3
4 NR 1.14E-03** 5.57E-03**
9 tiCi/mld NR NR NR NR Curies NR NR 1.37E-01** 3.27E-01**
6 jiCi/mI NR Curies NR
[tCi/n-d NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR 8
Curies NR
[iCi/ml NR NR NR 48 NR NR 3
NR 10 NR Liters Liters gagallons NR NR NR
- NR -- No liquid releases were made in the I"' 2nd 3rd and 4h quarters.
- Abnormal release. See documentation in the summary.
- The applicable limit is expressed in terms of dose. See Enclosure 1, Tables 5 through 8.
E3 -6
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID RELEASES FOR YEAR 2002 - BATCH MODE CURIES Isofie Ouarter (Required by Regulatory 1
(REG) Guide 1.21)
- 1.
Ba-140 NR*
- 2.
Ce-141 NR
- 3.
Co-58 NR
- 4.
Co-60 NR
- 5.
Cr-SI NR
- 6.
Cs-134 NR
- 7.
Cs-137 NR
- 8.
Fe-59 NR
- 9.
1-131 NR
- 10.
La-140 NR
- 11.
Mn-54 NR
- 12.
Mo-99 NR
- 13.
Nb-95 NR
- 14.
Sr-89 NR
- 15.
Sr-90 NR
- 16.
Tc-99m NR
- 17.
Xe-133 NR
- 18.
Xe-135 NR
- 19.
Zn-65 NR
- 20.
Zr-95 NR Others (Not Required by REG Guide 1.21)
CURIES Isotoe Ouarter Ouarter NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR Ouarter a
NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR Ouarter 4
NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR Ouarter 4
5.57E-03 **
Ouarter Ouarter 1
2 3
- 1.
F-18 NR NR 1.14E-03 **
NR -- No liquid releases were made during the Ist 2nd 3rd and 4th quarters.
- Abnormal release. See documentation in the summary.
E3-7
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES YEAR 2002 Units A. Fission and Activation Gases
- 1. Total Releases Curies
- 2. Average Release Rate for Period glCi/sec
- 3. Percent of Applicable Limit B. lodines
- 1. TotalIodine-131 Curies
- 2. Average Release Rate for Period p.Ci/sec
- 3. Percent of Applicable Limit C. Particulates
- 1. Particulates with half-lives
> eight days Curies
- 2. Average Release Rate for Period pICi/sec
- 3. Percent of Applicable Limit
- 4. Gross Alpha Radioactivity Curies D. Tritium
- 1. Total Release Curies
- 2. Average Release Rate for Period giCi/sec
- 3. Percent of Applicable Limit Ouarter Ouarter 1
2 1.59E+01 6.13E+01 2.05E+00 7.79E+00 4.03E-03 8.73E-02 5.18E-04 l.IE-02 Ouarter 3
1.20E+03 1.51E+02 4.58E-03 5.77E-04 1.41E-03 1.78E-04 ND 1.06E+01 1.34E+00 Ouarter Error 4
1.63E+03 45 2.05E+02 1.80E-01 36 2.26E-02 2.42E-03 35 3.051E-04 ND 6.38E+01 21 8.02E+00 1.12E-03 1.44E-04 ND**
3.10E+01 3.99E+00 1.13E-03 1.44E-04 ND 1.32E+01 1.67E+00
- Applicable Limits are expressed in terms of dose. See Enclosure 1, Tables I through 4.
- ND - Not Detected.
E3-8
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - ELEVATED RELEASE RIES Ouarter Ouarter Ouarter 1
2 3
CU]
N-13 Total for Period
- 2.
Iodines 1-131 I-133 Total for Period
- ND - Not Detected.
1.59E+01 ND*
ND ND ND ND ND ND ND 1.59E+01 2.44E-04 2.1 lE-04 4.55E-04 2.59E+00 ND ND ND 5.87E+01 ND ND ND ND 6.12E+01 4.03E-03 4.26E-04 4.46E-03 1.09E+02 ND ND 4.51E+01 1.04E+03 ND 3.65E+00 ND 7.72 E+00 1.20E+03 5.31E-04 2.61E-04 7.92E-04 Ouarter 4
2.03E+02 ND ND 8.82E+01 1.33E+03 ND 3.63E+00 ND ND 1.63E+03 5.42E-03 8.88E-04 6.31 E-03 E3-9
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORI YEAR 2002 GASEOUS EFFLUENTS - ELEVATED RELEASE Ouarter Ouarter Ouarter 1
2 3
CURIES
- 3.
Particulates*
Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Others (specify)
Rb-88 Rb-89 Sr-91 Y-91m Cs-138 Ba-139 Au-i 99 Total for Period*
- 4.
Tritium 9.95E-05 ND**
ND ND 9.21E-05 4.29E-05 ND 1.06E-Ol 2.38E-04 6.81E-04 2.35E-01 9.52E-02 2.16E-05 4.37E-01 7.27E-01 4.96E-05 ND 2.51E-06 2.05E-06 4.58E-05 1.62E-05 ND 2.21E-02 3.18E-04 5.02E-04 7.66E-02 5.60E-02 ND 1.56E-01 9.62E-01 8.66E-05 ND ND ND 5.13E-05 1.84E-05 ND 1.62E-01 6.21E-05 4.16E-04 2.74E-01 8.56E-02 4.07E-06 5.23E-01 1.60E+00 Ouarter 4
1.19E-04 ND ND ND 7.60E-05 2.32E-05 1.32E-01 3.25E-02 3.65E-04 5.98E-04 9.60E-01 1.211E-01 ND 1.25E+00 1.84E+00
- Includes all nuclides, even those with less than an eight day half-life.
- ND - Not Detected.
E3-10
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - GROUND RELEASE CURIES Ouarter Ouarter Ouarter Quaer 1
2 3
4
- 1. Fission Gases Kr-85m ND*
ND ND ND Kr-85 ND ND ND ND Kr-87 ND ND ND ND Kr-88 ND ND ND ND Xe-1 33 ND ND ND ND Xe-135m ND ND ND ND Xe-135 ND ND ND ND Xe-138 ND ND ND ND Others(specify)
NONE Total for Period ND ND ND ND
- 2.
Iodines I-131 1.88E-03 2.12E-03 1.01E-03 9.45E-03 I-132 ND ND ND 2.74E-04 1-133 4.20E-03 9.10E-04 1.03E-03 7.1 IE-03 1-135 ND ND ND 3.48E-04 Total for Period 6.08E-03 3.03E-03 2.04E-03 1.72E-02
- ND - Not Detected.
E3-11
CURIES
- 3. Particulates*
Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 La-140 Others (specify)
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - GROUND RELEASE Ouarter Ouarter Ouarter 1
2 3
4.13E-05 1.45E-07 1.63E-05 ND*
ND ND ND ND ND ND ND ND 6.54E-05 ND ND 1.24E-05 ND ND Ouarter 4
1.15E-04 ND ND ND 2.47E-05 ND ND ND ND ND 7.1 IE-04 3.68E-01 3.98E-02 4.08E-01 4.14E+00 Cr-51 ND 4.02E-05 Mn-54 1.22E-06 1.55E-05 Co-60 ND 1.699E-05 Sr-91 1.31E-04 ND Y-91m 1.42E-03 6.71E-06 Cs-138 3,16E-02 1.39E-02 Ba-139 2.71E-02 7.18E-04 Total for Period*
6.04E-02 1.47E-02
- 4.
Tritium 6.04E+00 2.03E+00
- Include all nuclides even those with less than an eight day half-life.
- ND - Not Detected.
ND ND ND ND 6.1 lE-05 5.60E-02 8.67E-03 6.47E-02 2.31E+00 E3-12
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - MIXED MODE RELEASE*
CURIES Ouarter Ouarter Ouarter Ouarter 1
2 3
4 1
Fission Gases Kr-85m ND**
ND ND ND Kr-85 ND ND ND ND Kr-87 ND ND ND ND Kr-88 ND ND ND ND Xe-133 ND ND ND 3.86E-02 Xe-135m ND ND ND ND Xe-135 ND ND ND 8.13E-03 Xe-138 ND ND ND ND Others(specify)
NONE Total for Period ND ND ND 4.68E-02
- 2.
lodines I-131 1.911E-03 8.12E-02 3.04E-03 1.65E-01 I-133 4.29E-03 4.33E-03 4.53E-03 4.65E-02 I-135 1.02E-04 ND ND ND Total for Period 6.30E-03 8.55E-02 7.57E-03 2.1 1E-01
- The Reactor Building and Radwaste Building are treated as split-level releases.
- ND - Not Detected.
E3-13
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - MIXED MODE RELEASE*
CURIES Ouarter Ouarter Ouarter Ouarter 1
2 3
4
- 3.
Particulates**
Sr-89 7.82E-05 3.35E-05 3.29E-05 8.82E-05 Sr-90 ND**
ND ND ND Cs-134 ND 1.12E-04 2.21E-04 4.60E-04 Cs-137 4.13E-06 1.70E-04 4.90E-04 7.90E-04 Ba-140 3.1 lE-04 7.85E-05 8.97E-05 2.54E-04 La-140 2.16E-04 1.14E-05 4.97E-05 7.87E-05 Others (specify)
Na-24 2.06E-04 2.36E-03 2.89E-03 1.34E-03 Cr-51 2.08E-04 1.52E-04 ND ND Mn-54 6.68E-05 1.21E-04 1.1 8E-04 1.05E-04 Co-58 1.1 8E-05 4.15E-05 6.76E-05 2.53E-05 Fe-59 1.48E-05 2.65E-06 ND ND Co-60 9.OOE-05 1.89E-04 1.12E-04 1.23E-04 Zn-65 ND 3.36E-05 5.40E-05 1.06E-04 Y-91m 2.93E-03 1.17E-03 2.50E-03 3.06E-03 Sr-91 2.96E-03 ND 2.53E-04 2.01E-03 Sr -92 2.47E-04 ND ND ND
- The Reactor Building and Radwaste Building are treated as split-level releases.
- Includes all nuclides, even those with less than an eight day half-life.
- ND - Not Detected.
E3-14
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - MIXED MODE RELEASE*
CURIES Particulates** (Continued)
Others (specify)
Mo-99 Tc-99m Ag-l lOim Cs-138 Ba-139 Au-1 99 Ouarter 1
5.53E-06 5.40E-06 3.86E-05 5.20E-03 6.63E-02 ND Ouarter 2
ND ND 2.OOE-05 ND 2.50E-02 1.54E-06 Ouarter 3
2.96E-05 2.89E-05 6.73E-05 ND 5.19E-03 ND Ouarter 4
3.01E-05 2.94E-05 l.33E-04 2.26E-02 8.51E-02 ND Total for Period**
7.90E-02 2.95E-02 1.22E-02 1.16E-01
- 4.
Tritium 2.42E+01 1.02E+01 6.70E+00 5,78E+01
- The Reactor Building and Radwaste Building are treated as split-level releases.
- Includes all nuclides, even those with less than an eight day half-life.
- ND - Not Detected.
E3-15
BROWNS FERRY NUCLEAR PLANT ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 2002 SOLID WASTE AND IRRADIATED FUEL A.
Solid Waste Shipped Off-site for Burial or Disposal (Not Irradiated Fuel)
- 1.
Tvpe of Waste
- a.
Spent resins, filter sludge evaporator bottoms, etc.
Units m3 Ci Amount O.OOE+00 O.00E+00 1.71 E+02 6.47E+01 Error %
+/-25.0
- b.
Dry compressible waste, contaminated m3 equipment, etc.
Ci
- c.
Irradiated components, control rod drives m3 0.O0E+O0 Ci 0.OOE+00
- d.
Cartridge filters m3 ci 0.OOE+OO 0.OOE+O0
- 2. Estimate of Major Nuclide Composition by Waste Type
- a.
Dry compressible waste, contaminated equipment, etc.
Nuclide Percentaae
- 1.
Iron5 5 (1) 7.62E+01
- 2. Cobalt6 0 (1) 9.54E+00
- 3. Manganese 5 4 (1) 7.1OE+00
- 4. Silver 11 0m (1) 2.06E+00
- 5. Cesium1 37 (1) 1.24E+00
- 6. Chromium 51 (1) 9.76E-01
- 7.
Iron59 (1) 8.85E-01
- 8. Zinc6 5 (1) 7.45E-01
- 9. Cesium 134 (1) 3.91 E-01
- 10. Cobalt5 8 (1) 3.27E-01
- 11. Nickel63 (1) 1.96E-01
- 12. Antimony'24 (1) 1.19E-01
- 13. Antimony'25 (1) 8.95E-02
- 14. Zirconium 95(1) 6.96E-02 4.51 E-C
- 15. Cerium14 4 (1) 3.98E-02
- 16. Strontium8 9 (1) 1.99E-02
- 17. Tin1 13 (1) 9.95E-03
- 18. Strontium9 0 (1) 3.71 E-05
- 19. Curium 24 3/2 44 (1) 3.09E-06 Activity (Curies) 4.98E+01 6.17E+01 4.60E+00 1.34E+00 8.05E-01 6.32E-01 7.73E-01 4.82E-01 2.53E-01 2.12E-01 1.27E-01 7.72E-02 5.79E-02 2.57E-02 1.29E-02 6.44E-03 2.40E-05 2.OOE-06 (1) Calculated E3-16
BROWNS FERRY NUCLEAR PLANT ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 2002 SOLID WASTE AND IRRADIATED FUEL
- 3. Solid Waste Disposition Number of Shipments 1
Mode of Transnortation (1) Non Sole Use Truck Destination US Ecology Oak Ridge, TN 42 1
(24) Sole Use Truck (18) Non Sole Use Truck (1) Non Sole Use Truck Duratek Oak Ridge, TN Tennessee Valley Authority Mixed Waste Storage Facility Muscle Shoals, AL B.
Irradiated Fuel Disposition Number of Shipments None Mode of Transportation N/A*
Destination NIA C.
Description of Shipments Number of Shipments 44 Type Container Strong Tight Package Type Quantity A-LSA II LTD QTY Number of Containers 52 Container Volume See Note Waste DAW Solidification Agents Used:
Absorbents Used:
None None NOTE: The 44 shipments of waste packaged in strong tight packages consisted of the following:
Type of STC 40"'Sealand 20' Sealand" 55 Gal drum Number of Packaaes Volume of Packaaes (m3 )
30 2.31 E+03 21 7.64E+02 1
2.1 2E-01 E3 -17
BROWNS FERRY NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT
SUMMARY
OF ABNORMAL/UNPLANNED RELEASES 2002 The release of radioactive material to the environment from Browns Ferry has been a small fraction of the 10 CFR 20 Appendix B and 10 CFR 50 Appendix I limits. There were no limits exceeded as specified in 10 CFR 20 Appendix B and 10 CFR 50 Appendix I.
No abnormal gaseous releases occurred in 2002. One abnormal liquid release was detected on August 14, 2003. The release consisted of low concentrations of Fluorine-1 8 and tritium from the Unit 3 station sump.
The chemistry database was searched for previous sump entries. All entries showed zero activity. The spectrum for the last clean sample was reviewed in the process of estimating the total activity released.
Traces of F-1 8 were discovered in the spectrum. A further investigation of 2002 and 2003 sump samples found traces of F-18 since 09/02/2002 13:13. Traces of tritium were found in the composite of batch releases made in August 2003 when the F-1 8 was first discovered. This level of H-3 activity was assumed to be present in all releases showing F-18. Doses from H-3 are very small and doses from F-18 are small due to its short half-life. Due to the travel time to the first public water supply, the trace levels of F-1 8 were reduced by a factor more than 1000 for each quarter. Details of the abnormal release are given in Problem Evaluation Report 03-015578. Problem Evaluation Report 03-022239 was written to address the F-18 not being identified in the spectra.
During the reporting period, January 1 through December 31, 2002, there were no missed compensatory measures.
In calendar year 2002 Browns Ferry had no changes to the radwaste system or the Process Control Program (PCP).
E3-18
ENCLOSURE 4 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)
UNITS 1, 2, AND 3 INOPERABLE RADIOLOGICAL EFFLUENT INSTRUMENTATION REPORT 2002 E4-1
INOPERABLE RADIOLOGICAL EFFLUENT INSTRUMENTATION REPORT 2002 This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (Offsite Dose Calculation Manual (ODCM)) Sections 1/2.1.1 and 1/2.1.2. The ODCM requires the exertion of best efforts to return inoperable instruments to operable status within 30 days. Failure to return such instruments to an operable status within the prescribed interval requires a description in the Annual Radioactive Effluent Release Report.
During the reporting period, January 1 through December 31, 2002, there were no radioactive gaseous effluent monitoring instrumentation out of service for greater than 30 days; however, one liquid effluent monitor was out of service for greater than 30 days. The Unit 1 RHR service water monitor (1 -RM-90-134) was considered inoperable between the times of 12-08-2001 0045 thru 01-07-2002 1207.
The monitor had tripped due to low flow conditions. Work Orders were initiated in a timely manner and work packages were planned for implementation based on a priority status of not exceeding 21 days. Initial troubleshooting of the flow problem was completed on 12-29-2001 and had resolved the flow problem.
However, during post maintenance testing activities, it was determined that a wiring error existed with a hand-switch in the pump start logic. A second work order was prepared to troubleshoot the wiring problem and was successfully completed on 01-07-2003. The monitor was then returned to service having exceeded 30 days by a few hours.
Some effluent monitors and flow instrumentation were placed in "out-of-service" status because these monitors' effluent streams were isolated. Therefore, these monitors are not included in this report.
E4 -2
ENCLOSURE 5 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)
UNITS 1, 2, AND 3 CHANGES TO THE OFFSITE DOSE CALCULATION MANUAL 2002 E5-1
CHANGES TO THE OFFSITE DOSE CALCULATION MANUAL (ODCM)
This report covers the period from January 1 through December 31, 2002. During this period, no change was made to the ODCM.
E5-2