I Tq!pL,&Iexion - FW: ANO Poison Insert Sketches I;~rn~ Alexion -- FW: A oso Inset& ktes5; e 04 Pageig 1 From:
'BURFORD, FRANCIS G <FBURFOR~entergy.com>
To:
"'twa~nrc.gov"' <twa~nrc.gov>, 'jIm3@nrc.gov'" <jIm3@nrc.gov>
Date:
1/8/04 2:33PM
Subject:
FW: ANO Poison Insert Sketches Tom - here are two sketches we had readily available and may be useful for any phone discussions.
Jerry Original Message-----
From: HOVIS, BILL D Sent: Tuesday, January 06, 2004 2:29 PM To: BURFORD, FRANCIS G
Subject:
ANO Poison Insert Sketches
--dlx FYI Bill Hovis, P.E.
Design Engineering Phone: (501) 858 4468 Fax: (501) 858 4955 bhovis@entergy.com
t dAWNDGWS\\TEMP\\G-W})0- 0 --0 0 I -.T M--P Page 1 1 I C:\\WINDOWS\\TEMP\\GWIOOOO1.TMP Paae 1 I Mail Envelope Properties (3FFDBO62.8FC:12: 2300)
Subject:
Creation Date:
From:
Created By:
FW: ANO Poison Insert Sketches 1/8/04 2:29PM "BURFORD, FRANCIS G" <FBURFOR@entergy.com>
FBURFOR@entergy.com Recipients nrc.gov owf4_po.OWFNDO TWA (Thomas Alexion)
JLM3 (John Minns)
Post Office owf4_po.OWFNDO
- Route nrc.gov Files MESSAGE Part.001 insert.PDF Mime.822 Options Expiration Date:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
Size 361 1266 89188 102484 Date & Time 01/08/04 02:29PM None Standard No None No Standard
Seismic Re-qualification of the Arkansas Nuclear One Unit 1 Spent Fuel Racks By: 0. Coman Checked: P.R. Wilson
-A A
ll;.
III' Isometric vie halves' X4 _
- v-ew of Insert and Detail showing Wedge Blocks and Horizontal Supports between Insert
-x Two spot welds per side (typ)
Y Cross Section through insert at location of Bands Calculation ANO-ER-02-051 56
Seismic Re-qualification of the Arkansas Nuclear One Unit I Spent Fuel Racks By: 0. Coman Checked: P.R. Wilson Ci to I.0
.0 (0
C.,
Ito
'PR a0
- 1 C..J U)
-i--AT Z~j
.,)
I-F-.
Cs)
I I
I I
E~n C.)
I.-I I.
C')
Location Dimensions of Bands and Wedge Blocks Calculation ANO-ER-02-O5l 57 Calculation ANO-ER-02-051 57