Text

NMC7)

Committed to Nuclear Excellenc DAEC EMERGENCY PLANNING DEPARTMENT PROCEDURE TRANSMITTAL ACKNOWLEDGEMENT MEMO (TAM-1l1)

To:

NRC-NRR Document Control Desk US NRC Washington DC 20555 Re:

Entire EPIP Document (Copy 28)

PSM

Title:

n/a Distribution Date:

01 / 14 / 2004 Effective Date of Change:

01 /21 /2004 Return by:

02/04 / 2004 Please perform the following to your assigned manual. If you have any questions regarding this TAM please contact Don A. Johnson at 319-851-7872.

REMOVE Rev. 147 EPIP Table of Contents Revision INSERT Rev. 148 Rev. 21 EPIP 3.3 (PWR: 23183)

Rev. 20 PERFORMED BY:

Print Name Sign Name Date Please return to:

K. Dunlap PSC/Emergency Planning 3313 DAEC Rd.

Palo, IA 52324 To be completed by DAEC EP personnel only:

Date TAM returned:

EPTools updated:

-\\

(Lf '15-)

i P Page 1 of 1

t Committed to Nuclear e celn Duane Arnold Energy Center Operated by Nuclear Management Company, LLC Wednesday, January 14, 2004 NRC-NRR Document Control Desk US NRC Washington, DC 20555 To: NRC-NRR Document Control Desk From: DAEC Emergency Planning Department Re: Description of changes to the following documents EPIP 3.3 Dose Assessment and Protective Action Added more guidance to assist the Rad Pro Staff in determining PAR changes based upon wind direction and/or Dose Projection changes. No adverse effect on the procedure as this change only serves to ensure consistent understanding of DAEC and State & County expectations regarding changes in PAR's for wind direction and/or dose projection changes.

Please contact Paul Sullivan, Manager of Emergency Preparedness at DAEC, (319)851-7191, if you require further information.

3313 DAEC Road - Palo, Iowa 52324-9785 Telephone: 319.851.7191 - Fax: 319.851.7364

1EMERGENCY PLAN IMPLEM~iENTING PROCEDURES Rev 148 INDEX PAGE 1 of 7 Procedure Title Revision Date

-Number

-1.1 Determination of Emergency Action Levels 22 11/21/03-1.2 Notification

^

29

-10/13/03 1.3 Plant Assembly and Site Evacuation 9

09/i 2/01 1.4 Release of Emergency-Related nformation 5

10/13/03

-1.5 Activation and Operation of the EOF 5

10/13/03 2.1 Activation and Operation of the OSC 14 10/13/03 2.2 Activation and Operation of the TSC 24 10/13/03 2.3 Operation of the FTS-2001 Phone Network 7

10/13/03 2.4 Activation and Operation of the ORAA 8

09/12/01 2.5 Control Room Emergency Response Operation -

15 10/13/03-2.6 Activation and Operation of the ORAL9 12/30/02 2.7 Activation and Operation of the ODEF 6

10/15/01 2.8 Security Threat 2

7/30/03-3.1 In-Plant Radiological Monitoring 1 3 10/13/03 3.2 Field Radiological Monitoring 14' 10/13/03 3.3 Dose Assessment and Protective Action 21 1/21/04 4.2 First Aid, Decontamination and Medical Support 7

8/23/02 4.3.

Rescue and Emergency Repair Work 11 8/23/02 4.5 Administration of Potassium Iodide (KI) 7 -

2/10/03 5.2 Recovery and Re-entry 10 10/13/03

,,.EM~ERGENCY,.PlL AN' IMP,,i EMENTINGlPROCED(RS rIRe 4

INDEX PAGE 2 of 7 t Form

-Title Revision Referencing Number Number Procedure CR-01 OSM/OSS Checklist Rev. 4 EPIP 2.5 CR-03 Dose Projection & ARM Data Sheet Rev. 0 EPIP 2.5 CR-04 Control Room to TSC Transfer Checklist Rev. 2 EPIP 2.5 CR704~~~~~~~~

~

~~~~~~~~~~~

Rev

.I 2.5.

EAL-O1 Abnormal Rad Levels/Radioactive Effluent Table Rev. 5 EPIP 1.1 EAL-02 Fission Barrier Table Rev. 4 EPIP 1.1 EAL-03 Hazards & Other Conditions Affecting Plant Safety

' Rev. 5 EPIP 1.1 EAL-04 System Malfunction Table Rev. 4 EPIP 1.1 EAL-05 ISFSI Table--

Rev. 0 EPIP 1.1 EOF - 02 NRC-- HPN Communicator Checklist Rev. 3 EPIP 1.5 EOF - 03 Technical Recorder Checklist Rev. 2 EPIP 1.5 EOF - 04 Summary of Computer Data Backup Collection Rev. 2 EPIP 1.5 Activities EOF - 05 EOF Information Services Representative Checklist Rev. 3 EPIP 1.5 EOF - 06 DAEC Key Parameter Log Rev. 0 EPIP 1.5 EOF - 07 Emergency Response and Recovery Director Rev. 5 EPIP 1.5 Checklist EOF - 08 Rad & EOF Manager Checklist Rev. 7 EPIP 1.5, 3.3 EOF -09 EOF OPS Liaison Checklist Rev. I EPIP 1.5 EOF-10 EOF-Communicator Checklist Rev. 3 EPIP 1.5 EOF-11 Support Services Coordinator Checklist Rev. 3 EPIP 1.5 EOF-12 Field Team Director Checklist Rev. I EPIP 1.5, 3.3

I EOF-14 EOF MIDAS Operator Checklist Rev. 1 EPIP 1.5,3.3 EOF -15 Radiological Data Plotter Checklist Rev. 0 EPIP 1.5,3.3 EOF -16 Radiological Assessment Coordinator Checklist Rev. 2 EPIP 1.5,3.3 EOF - 17 EOF Security Access Clerk Checklist -

Rev. 3 EPIP 1.5 EOF-18 EOF Staffing Accountability Roster-Rev. 4 EPIP 1.5 EOF - 19 Drill Anmouncemnent Message Rev. 0 EPIP 1.4, 1.5 EOF -20 Emergency Announcement Message

-Rev. I EPIP 1.4,1.5 EOF - 21 Personnel Access Log Rev. I EPIP 1.4,1.5 EOF -22 Registration Form Rev. 0 EPIP 14,1.5 EOF Security Post Log Rev. 2 EPIP 1.4; 1.5 EOF -24 First Floor Security Post Description Rev. 2 EPIP 1.4,1.5 EOF -25 Fourteenth Floor Security Post Description Rev. 1 1 EPIP 1.5 EOF Status Update Message - EOF Communicator Rev. 0 EPIP 1.5 EOF Verbal Closeout Summary Rev. 0 EPIP 1.5 EOP -29 Written Closeout Summary Rev. 0 EPIP 1.5 EOF-30 Status Board Rev., 1 EPIP 1.5 EOF -31 Access B adge Example Rev. 0 EPIP 1.5 EOF -32 EOF Staff Response Rev. 4 EPIP.15 EOF-33 Recoverylssues Rev. 0 EPIP 5.2 EOF 34 EOF Activities Rev. 0 EPIP 5.2 EOF -35 Recovery Phase Plan Outline Guidance Rev. 0 EPIP.52 EOF-36 RE-Entry Briefing Guide Rev. 0 EPIP 5.2 EOF -37 RE-Entry Debriefing Guide Rev. 0 EPIP 5.2, EOF-38 EOF Messenger Checklist Rev. I EPIP 1.5 ERO -01 ERO Position Equivalency Table Rev.1 EPIP 1.5 JPIC-01 JPIC Manager Checklist Rev. 4 EPIP 1.4 JPIC -03 Alliant Spokesperson Checklist F

Rev. 3 EPIP 1.4

74,

-EMERGENT.J..LAN;IMq <EME NTING',PR0CeEDUfZES Rev.148

:INDEX PAGE 4 of 7 JPIC - 04 Technical Liaison Checklist Rev. 4 EPIP 1.4 JPIC-05 Sequence of Events Rev. 0 EPIP 1.4 JPIC- 06 Public Information Officer Support Checklist Rev.5 EPIP 1.4 JPIC - 07 Logistics Coordinator Checklist Rev. 4 EPIP 1.4 JPIC- 08 Logistics Support Checklist Rev. 4 EPIP 1.4' JPIC - 09 Audiovisual Support Checklist Rev. 4 EPIP 1.4 JPIC - 11 Rumor Control Coordinator I Checklist Rev. 3 EPIP 1.4 JPIC - 12 Rumor Control Event Summary Log Rev. I EPIP 1.4 JPIC - 13 Rumor Control Coordinator II Checklist Rev. 2 EPIP 1.4 JPIC -14 Public Rumor Control Checklist Rev. 2 EPIP 1.4.

JPIC - 15 News Media Rumor Control Checklist Rev. 4 EPIP 1.4 JPIC -16 Assistant JPIC Manager Checklist Rev. 3 EPIP JPIC -17 JPIC Security Access Control Checklist Rev. 3 EPIP 1.4 JPIC - 18 Sixth Floor Security Post Description Rev. 2 EPIP 1.4 JPIC-19 JPIC Distribution List Rev. 2 EPIP 1.4 NOTE-01 ERO Notification-Phone System Callout Rev. 5 EPIP 1.2 NOTE-02 ERO Notification -' Alphanumeric Paging System Rev. 3 EPIP 1.2 Callout NOTE-03 Event Notification Worksheet

'Rev. I EPIP 1.2 NOTE-04 Plant Assembly Notification Rev. 2 EPIP 1.2 NOTE-05 Emergency Action Level Notification Rev. 7 EPIP 1.2 NOTE-06 Plant Page for Emergency Classification Changes Rev. 1 EPIP 1.2 NOTE-07 Basic Notification Flowpath Rev. 2 EPIP 1.2 ODEF-01 ODEF Deconiaminaition Waiting Area Rev. 0 EPIP 2.7 ODEF-02 Floor Plan for ORAUODEF Rev. 0 EPIP 2.7 ODEF-03 Travel Route to ORAIJODEF Rev. 0 EPIP 2.7 ODEF-04 12 h Avenue Entrance to ORALODEF Rev. 0 EPIP 2.7 ORAA-01 Offsite Relocation and Assembly Area Supervisor's Rev. I EPIP 2.4 IJ

I>

K)j

,LEMiERGENCY-PLANJIMPLElwTINGPRt)C+DURES ;<'!Rev. 148

.I.

NDvEX r..PAGE 5 of 7 Checklist ORAA-02 Health Physics Support for the Offsite Relocation Rev. 0 EPIP 2.4 and Assembly Area ORAA-03 Security Support for the Offsite Relocation and Rev. 0 EPIP 2.4 Assem bly Area ORAA-04 Offsite Relocation and Assembly Area Rev. 0 EPIP 2.4 ORAA-05 Ofite Relocation and Assembly Area Parking and

'Rev.0 EPIP 2.4 Vehicle Monitoring OSC-01' OSC Layout Rev. 0 EPIP 2.1 OSC-03 Minimum Staffing Level Rev. 2 EPIP 2.1 OSC-04 Recommended Log Entry Topics Rev. 0 EPIP 2.1 OSC-05 Emergency Event Log Sheet Rev. 0 EPIP 2.1 OSC-06 Personal Statement Concerning Incident' Rev. 0 EPIP 2.1 OSC-07 Emergency Exposure Tracking Log Rev. 0 EPIP 2.1 OSC-08 OSC Supervisor Checklist

. Rev. 0 EPIP 2.1 OSC-09 Health Physics Supervisor Checklist,

Rev. 0 EPIP 2.1 OSC-10 IC/EM & Mechanical Supervisor Checklist Rev. I EPIP 2.1 OSC-1l Emergency Assignment.Staffing Board Duties Rev. 0' EPIP 2.1.

OSC-12 External Exposure Limits Rev. 0 EPIP 4.3 OSC-13 Guidance on Dose Limits for Workers Performing Rev. 0 EPIP 4.3 Emergency Services.

OSC-14 Guidelines Regarding Selection of Volunteers Rev. 0 EPIP 4.3 OSC-15 OSC RepairTeam Work Order'.

Rev'. 0 EPIP 4.3 OSC-16 Repair Team Datasheet Flowpath Rev. 0' EPIP 4.3 OSC-17 Field Monitoring Team Checklist Rev. 0 '

EPIP 2.1 PAR - 01 PAR Decision Making-Recommendations Rev. 0 EPIP 3.3 PAR - 02 PAR Decision Making - Flowchart Rev. 0 EPIP 3.3

-PASE-02 Onsite Assembly Locations Rev. 2 EPIP 1.3 I

PASE-05 Site Evacuation'Rotes I

Rev. I I I i EPIP 13 -

.-;EMERGENCYi PILA imp MLEtNTINGT IRRCEDURStRv 4

- INDEX PAGE 6 of 7-SAM-01 EOP-SAG Transition Checklist Rev.' 0 EPIP 2.2 TSC-01 Emergency Coordinator Checklist Rev. 4 EPIP 2.2 TSC-02 TSC-EOF Transfer Checklist' Rev. 3 EPIP 2.2 TSC-03 Site Radiation Protection Coordinator Checklist Rev. 2 EPIP 2.2 TSC-04 Technical & Engineering Supervisor Checklist Rev. 4 EPIP 2.2 TSC-05 Quality Assurance Checklist Rev. 1 EPIP 2.2 TSC-06 Security & Support; Supervisor Checklist Rev. 2 EPIP 2.2 TSC-07 Administrative Supervisor Checklist Rev. 2 EPIP 2.2 TSC-08 Material Management Supervisor Checklist Rev. 2 EPIP 2.2 TSC-09'-

TSC Communicator Checklist Rev. 3 EPIP 2.2 TSC-10 CR-Communicator Checklist Rev. 4 EPIP 2.2 TSC-12 ENS Communicator Checklist Rev. 2 EPIP 2.2-TSC-13 HPN Communicator Checklist Rev. I EPIP 2.2 TSC-14 TSC/OSC Operations Liaison Checklist Rev. 2 EPIP 2.2 TSC-15 Radiological Support Staff Checklist Rev. 2 EPIP 2.2 TSC-18 TSC MIDAS Operator Checklist Rev. 0 EPIP 2.2 TSC-19' Technical & Analysis Engineer Checklist Rev. 2 EPIP 2.2 TSC-20 TSC Operations Supervisor Rev. 3 EPIP 2.2 TSC-21 Electrical Engineer Checklist A

Rev. 1 EPIP 2.2 TSC-23 Mechanical Engineer Checklist Rev. 0 EPIP 2.2 TSC-24 Reactor Engineer Checklist Rev. 2 EPIP 2.2 TSC-26 Information Services Representative Checklist Rev. 2 EPIP 2.2 TSC-27 Fire Marshall Checklist Rev. 1 EPIP 2.2 TSC-28 NRC Roles During A Nuclear Power Plant Rev. 0 EPIP 2.2 Emergency Checklist --

TSC-29 TSC Minimum Staffing Level Rev. 3 EPIP 2.2-TSC-30 Emergency Action Request Log Rev. 0 EPIP 2.2 TSC-3 1 Radio Operator Log Rev. 1 EPIP 2.2 I>

K1)

'4 ;, I., I.. I ! i`, I -,

I

. I -

07 I

I

,, - 

INDEX PAGE 7 of 7 TSC-33 Typical.OrganizationoftheNRCSiteTeam Rev. 0 EPIP 2.2 TSC-34 TSC Organization Chart Rev. 4 EPIP 2.2 TSC-35 Assignment Form Rev. 0 EPIP 5.2 TSC-36 Deactivation Report Rev. 0 EPIP 5.2 TSC-37 Plant Operations Status Rev. 0 EPIP 5.2 TSC-38 TSC/Control Room/OSC Activities Rev. 0 EPIP 5.2.

TSC-39 TSC Clerical Checklist Rev. 0 EPIP 2.2 TSC40 ARM Locations Rev. 0 EPIP 3.1/4.3 TSC-41 PASS Capabilities Rev. 0 EPIP 3.1 TSC42 On-Site Map Rev. 0 EPIP 3.2 TSC43 ESB Logon Instructions (TSC/CR/EOF)

Rev. 0 EPIP 2.2 I

4-.

'- EMERGENCYPLAN.IMPLMENTINGPROCEDURES' EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 1 of 28 Effective Date:.,

'r.~~

~1' i

ji' i

i 3-

-}.,

F TECHNICALREVIEW Prepared by:

Date:

/Z//o/03 Reviewed by:

Date:, IZli 165 '

Inependent Reviewer APPROVAL ::

I am responsible for.the technical content of this procedure.

Approved by: t Date:

Manager, Ermergency.Planning

.I I

EMERGENCYPLAN IMPLMENTING PROCEDURES 7L EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION:

Page 2 of 28 Table of Contents Page 1.0 PURPOSE 3

2.0 DEFINITIONS 3

3.0 INSTRUCTIONS 3

3.1 PAR DECISION MAKING.

3 3.2 INITIAL AND PERIODIC BRIEFINGS............................

'.6 3.3 PAR'S DUE TO CHANGES IN WIND DIRECTION/DOSE PROJECTIONS.9........9 3.4 OFFSITE RADIOLOGICAL MONITORING TEAMS......................... 11 3.5 DOSE PROJECTION ACTIVITIES...............................................

13 3.6 COORDINATION OF. DOSE ASSESSMENT WITH THE STATE OF IOWA...............................................

14 3.7 DATA RECORDING AND TREND ANALYSIS FROM THE TSC..... 15 3.8 DATA RECORDING AND TREND ANALYSIS FROM THE EOF..... 16 3.9 RE-ENTRY AND FOLLOW-UP ACTIVITIES.17 4.0 RECORDS 17

5.0 REFERENCES

17 6.0 ATTACHMENTS 18 ATTACHMENT 1, EVACUATION TIME ESTIMATES

.19 ATTACHMENT 2, WIND DIRECTION AND AFFECTED SUBAREAS POPULATIONS FOR DAEC EPZ.27 ATTACHMENT 3, WIND DIRECTION AND AFFECTED SUBAREAS 28

-EMERGENCY PLAN IMPLMENTING PRCEDURES EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 3 of 28 1.0 PURPOSE (1) This procedure provides instructions for directing offsite radiological monitoring activities performed by Duane Arnold Energy Center (DAEC) coordinating such activities with those accomplished by the State of Iowa, assessing the offsite radiological impacts of an event at the DAEC, and formulating Protective Action Recommendations.

2.0' DEFINITIONS (1) MIDAS (a)

Meteorological Information and DoseAssessment System.

(2)

PAR (a)

(Protective Action Recommendation) - Made to the State with regards to evacuation or sheltering of subareas within the Emergency Planning Zone (EPZ).

(3)

PAG (a)

(Protective Action Guides) - Established by the Environmental Protection Agency (EPA) Reference 2.

3.0 INSTRUCTIONS 3.1 PROTECTIVE ACTION RECOMMENDATION DECISION MAKING.

(1) At the initial Emergency Classification declaration, theo n-shift chemist reports to the TSC MIDAS Computer to initiate MIDAS dose projection runs. Projected

'off-site doses shall be communicated to the Control Room, until the TSC is activated.

EMERGENCY PLANIMPLMENTING PROCEDUERES

,'EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 4 of 28 a...

~~~~~~~~~~~.

V>

(2)

Plant conditions and/or dose projections (as available) shall be reviewed to determine:

(a) If the Emergency Action Level (EAL) has changed, reclassification of the event is necessary andlor protective actions are warranted.

(b)

If the EPA Protective Action Guides (PAGs) are being exceeded and if protective acti6ns'are warranted or need to be revised..

(3)

There are two tables intended to assist in the recommendation of appropriate protective actions to the State of Iowa, PAR-01 and PAR-02. The Protective Action Recommendations for emergency classification levels and radiological releases impacting the areas outside of the site boundary, are in PAR-01. The Protective Action Recommendations for Severe Core Damage or loss of control of plant functions are contained in PAR-02. All protective actions listed are appropriate for the conditions indicated but do not restrict the decision-maker(s) should it be desirable to recommend other protective actions based on the situation at the time of the emergency.

(4)

When an emergency class has been declared, or dose projections are available for radiological releases, go to PAR-01. PAR-01 allows for the assessment of appropriate protective actions based on downwind dose projections resulting from airbome radiological releases.

(a)

Protective Action Recommendations shall be recorded in your log, the Status Board and NOTE-05.

(b)

To determine the subareas affected and the maximum evacuation time (if needed), refer to Attachment 1, Evacuation Time Estimates".

(c)

Continue to work through the table as new classifications are determined or dose projection information becomes available.

(5)

If the incident is classified as a General Emergency, with core damage as specified in PAR-02, recommend the minimum protective action as given in PAR-02. PAR-02 allows for the assessment of a core melt sequence and provides appropriate protective actions based on the conditions adopted from Section G of the RTM-96.

(a),

Enter the table at the top decision block which asks, "Actual or projected severe damage or loss of control of facility".'

EMERGENCY PLAN IMPLMENTING PROCEDURESs i-,i 5&j. EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 5 of 28 (b) To determine the sectors affected and the maximum evacuation time (if, needed), refer to Attachment 1, "Evacuation Time Estimates.".

(6)

Continue to work through the table as new information becomes available.

(7)

Protective Action Recommendations should be determined (forecast weather information should be considered during all Protective Action Decision Making) by:

(a) The Operations Shift Manager/Supervisor if neither the TSC nor the EOF is activated.: This person is responsible for ensuring that Protective Action Recommendations are provided to offsite authorities.

(b)

The Site Radiation Protection Coordinator once the TSC is activated.

,This person shall develop these recommendations for approval by the Emergency Coordinator. The Emergency Coordinator shall ensure that this information is provided to offsite authorities.

(c)

The Radiological and EOF Manager, assisted by the Radiological.

Assessment Coordinator, upon activation of the EOF.. These persons shall assume responsibility for development and recommendation of the

-Protective Actions and, upon approval by the Emergency Response and, Recovery Director, provide formal communication of these recommendations to offsite agencies.

(8)

Recommend the Protective Actions as specified in PAR-01 for all declared events.

(a). If the situation is degrading such that a potential exists for declaration of a General Emergency, evaluate trends and prognosis for change to determine the need for precautionary, protective measures for the general public.

(b)

Pay special attention to wind direction as this may lead to a Protective Action Recommendation for other affected subareas, reference Attachment 3, 'Wind Direction and Affected Subareas'.

[Reference EPIP 3.3 step 3.3]

(9)

Field readings should be used to evaluate Protective Action Recommendations. If a significant number of actual doserates, measured in the field, are greater than those projected to be occurring at the time, consideration should be given to upgrading or expanding the current protective actions, as appropriate.

-EMERGENCY PLAN IMPlMENTING PROCEDURES' 'I ~t;e- ;.' EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 6 of 28 (10) Formulated Protective Action Recommendations'shall be recorded on NOTE-05, 'Emergency Action Level Notification Form'.

(a), The Emergency Coordinator/Emergency Response and Recovery Director shall approve the Protective Action Recommendations by signing NOTEZO5,' 'Emergency Action Level Notification Form'.

(11) The SRPC/Radiological and EOF Manager should release Protective Action Recommendations in the following manner:

(a) [EOF] Short pre-briefing of impending recommendations'and related plant conditions'should be given to State EOC Dose Assessment personnel via the microwave phone.

(b) When the EOF is activated this briefing shall be followed by official recommendations being delivered via the "Administrative Hotline" within 15 minutes of recognizing the criteria.-

(c) State, County, and Federal notifications shall be made in accordance with EPIP 1.2, 'Notification'.'

(12) Information regarding-emergency classification, plant status, offsite radiological data, Protective Action Recommendations, and response actions underway shall be provided when significant changes occur and on' a periodic basis to the ERO, Linn and Benton County EOCs, the State EOC, and the NRC in accordance with'EPIP 1.2, 'Notification'.

(13) If protective actions actually implemented by local and State officials differ from those recommended by DAEC, the Emergency Coordinator/Emergency Response & Recovery Director should be informed and this shall be annotated on NOTE-05 block 12 'Additional Information'.

(14) The Protective Action Recommendations will be continuously assessed and changed,' as appropriate, depending upon the changing conditions.

3.2 INITIAL AND PERIODIC BRIEFINGS (1) Prior to assuming responsibility for offsite radiological monitoring and dose assessment activities, the Site Radiation Protection Coordinator/Radiological Assessment. Coordinator should obtain the following information:

K'

EMERGENCY-PL N IMPLMENTING PROCEDURES'@i.'

EPIP 3.3' Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 7 of 28 (a)

Effluent release information, if a release is in progress, including the release point and release concentration from the KAMAN Effluent Monitoring System.

(b)

Weather forecast information. This information can' be obtained from the National Weather Service (phone number listed in the ETB).

(c)

Meteorological information, including stability class (or AT), wind speed and wind direction from the Safety Parameter Display System (SPDS). If meteorological information cannot be obtained from SPDS via the Met

.Tower; then call the National Weather Service phone number and; request an update of the current Met conditions.

(d) The results of dose projection calculations.

(e)

Containment High Range Radiation Monitor levels.

(f)

Protective Action Recommendations which have been made.

(g)

On-site radiological information, post-accident sampling activities, and effluent release isotopic mixes, if available.

(h)

Status of off-site monitoring activities conducted, if any, and locations of the DAEC Off-site Radiological Monitoring Teams."'

(i)

-Plant status information and prognosis for deteriorating conditions.

~- r (j)

The status of activation of the Off-site Radiological and Analytical Laboratory (ORAL).

(k)

The status of activation of the Off-site Radiological and Assembly Area (ORAA).

(2)

-The Site Radiation Protection Coordinator should summarize this information, advise the Emergency Coordinator of pertinent points discussed, and brief the Radiological Assessment Group.

OR The Radiological Assessment Coordinator should summarize this information, advise the Radiological and EOF Manager of pertinent points discussed, and brief the Radiological Assessment Group.

EMERGENCY. PLAN,IMPLMENTING PROCEDUlJES?'-

EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 8 of 28 (a) The Field Team Director should ensure that the Offsite Radiological Monitoring Teams are apprised of pertinent information regarding plant potential radiological problems expected.

(b) Caution should be exercised in relaying information to teams over the radio; since the radio transmission becomes public information. Only transmit information that is necessary for the field teams to perform their duties safely and information that is made public through news releases.

(3) The Field Team Director should'ensure that the meteorological and field team information on the DAEC EPZ mapslstatus boards are updated and maintained. Items such as the following should be considered for display.

(a) Wind direction (b) Wind speed -

(c) Stability class,.

(d)

Weather forecast information (e) Plume width and centerline (f)

Team locations-(g) Survey results at selected locations and an outline of the subarea Protective Action Recommendations as necessary.

(h)

Projected TEDE doses or dose rates in the plume path (i)

Projected thyroid doses or dose rates in the plume path (4) Additionally, the Radiological Data Plotter in the EOF should display selected radiological information obtained by the State monitoring teams, as reported by the State. Field Team Captain in the EOF.

EMERGENCYiPLAN IMPLMENTINGROCEDURES EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 9 of 28 3.3 PAR'S DUE TO CHANGES IN WIND DIRECTION/DOSE PROJECTIONS NOTE State.-- &

County protective. actions are formulated based upon several. factors, some of which are known by DAEC (wind direction, dose projections, field team results,- etc) and some of which are known only to the State &

Counties -(road restrictions,.ongoing 'events',

etc). It is imperative that DAEC gives the.State

& Counties the information they.need, when they need it, and in a consistent format and process.

3.3.1 WIND DIRECTION CHANGES I

. f I

(1) When at a Site Area or General Emergency, the wind direction documented on the last NOTE-05 communicated to the State & Counties sets the boundaries of acceptable wind directions thatwould not require a change in PARs (reference Attachment 3). When the wind shifts beyond the boundaries established via the last NOTE-05, a change in the PAR is required. This is required even at a Site Area Emergency as the State & Counties usually relocate school populations,.(that are in the sub-areas affected by the established wind-direction given to them by DAEC), to Temporary Relocation Centers (TRC)..

(a) The first 15-mmin clock starts when the wind shift occurs (50m Wind Direction from the PPC is the 'normal' data source), -It stops when the PAR is determined (time-annotated on block 11 of NOTE-05).

(b) The second 15-min clock starts when the PAR is determined (time annotated on block 11 of NOTE-05). It stops when the first State or County responder answers the phone (time annotated on NOTE-05 "Message Initiated").

(2) When the wind direction is continuously changing/swinging beyond the boundaries of Attachment 3, it is HIGHLY RECOMMENDED that DAEC asks the State & Counties to increase the boundaries to incorporate these postulated or actual wind shifts so as to minimize the need to constantly be completing and communicating.NOTE-05's andethus const anging the

-. EMERGENCY PLAN IMPLMENTING;PROCEDURES EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION -

Page 10 of 28 information to the public and offsite emergency managers. This shall be documented on the NOTE-05.

(a) For example, assume a Site Area Emergency was declared with a wind direction of 145 degrees with no additional boundary expansion mentioned on tie NOTE-05. The wind direction then changes to 148 degrees and is swinging back and forth over the boundary of 146.25.

(i) Communicate with the State/Counties. Inform them of the wind shift and upcoming PAR change and 'ask for an' expansion of the boundaries to incorporate ind'shifts ir the bounds of 123.76 to 168.75'degrees.' If they agree, annotate this expansion on the NOTE-05'and formally communicate it in accordance with EPIP 1.2.

(ii) This now sets the boundaries for wind direction changes that DO NOT need a new PAR to be determined and' communicated.

NOTE The wind direction boundaries documented on' the LAST NOTE-05 establishes the range of wind direction that can occur without a' corresponding change in PAR & therefore

. NOTE-05. This is regardless of any actions already taken by'the State/Counties to-increase the wind direction boundaries. DAEC-is required to formally notify and document PARs (which includes wind direction) via NOTE-05.-i 3.3.2 DOSE PROJECTION CHANGES-(1) Changes in the dose projections only effect PARs determined at the General Emergency level. When a General Emergency is declared,' the PAR (block 11 of NOTE-05) is either set at the default setting, or set based upon the latest dose projection from MIDAS.'

(a) For example: 'A General Emergency is declared using the default PAR.

Later, while still'at a General Emergency, the MIDAS dose projection dictates a change in the' PAR.: We have 15-minutes to make the PAR KIj

-i,,,EMERGENCY;PLAN IMPLMENTING PROCEDURES EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION...

o¢,ffi,,44 Ki,.v;,

Page 11 of 28 determination once the dose projection shows the need to do so, and then 15-minutes to notify the State & Counties.

(i) The first 15-min clock starts when the Dose Projection is reviewed and signed by the RAC or SRPC. It stops when the PAR is determined (time annotated on block 11 of NOTE-05).

(ii) The second 15-min clock starts when the PAR is determined (time annotated on block 11 of NOTE-05). It stops when the first State or County responder answers the phone (time annotated on NOTE-05 Message Initiated").

,-NOTE.

Every change in Dose Projections that necessitate a change in PAR SHALL be determined and communicated in accordance with EPIP 1.2 regardless of State/County actions already underway. It is not permitted to expand the PAR beyond what our dose,,-,

projections dictate.

(b)

An important caveat to the process for changing PARs based upon dose projections is that we cannot recommend sheltering sub-areas that we have previously recommended be evacuated and the State/Counties are in the process of evacuating (reference RIS 2003-12). This scenario only occurs at a General Emergency where we have made a PAR based upon elevated dose projections and then subsequent dose projections show decreasing dose levels that would necessitate a.new 'lower' PAR.

(i) In this very infrequent situation, the proper protocol to follow is to discuss the PAR with the State & Counties, determine what the correct PAR should be,- and DOCUMENT THIS ON THE NOTE-05 (block 12).- All relevant time constraints still apply.

3.4 OFFSITE RADIOLOGICAL MONITORING TEAMS (1) Offsite Radiological Monitoring Teams should be initially briefed and dispatched in accordance with EPIP 3.2, "Field Radiological Monitoring".

.It~t... EMERGENCY PLAN IMPLMENTING PROCEDURES EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION -'

Page 12 of 28 K)~

(2) -. In preparation for directing the Offsite Radiological Monitoring Teams, the Field Team Director should:--'

(a) Conduct a radio check with the Teams and verify their locations.

(b) Advise the Teams of the latest radiological and plant status information, as necessary to perform their duties safely.

(c) Inform the Site Radiation Protection Coordinator of readiness to assume control of the Offsite Radiological Monitoring Teams.-

(3) Direction and control of the Offsite Radiological Monitoring Teams should be done in accordance'with the directions given in EPIP 3.2.

(4) In preparation for assuming.control of the Offsite Radiological Monitoring Teams, the Field Team Director should:.

(a) Contact the TSC Field Team Director'and inform them of the intent to establish contact with Teams.

(b) Conduct radio check with the Teams and verify their locations.

(c) Advise the Teams of the latest radiological and plant status information, as necessary to perform their duties safely.

(d) Inform the Radiological Assessment Coordinator of readiness to assume control of the Field Radiological Monitoring Teams.

NOTE There are 2 TSC Field Team Directors that report to the TSC when activated. When the

.. EOF is to be activated, I of these Field Team Directors relocates to the EOF to assume control of the Offsite Field Teams. The' remaining Field Team Director in the TSC maintains control over the Onsite. Field Team,..

and the Offsite Field Team while the other Field Team Director is in transit to the EOF.

(5) When the EOF has been activated, the Radiological Assessment Coordinator should contact the Site Radiation Protection' Coordinator and advise that the EOF is ready to assume control of the Offsite Radiological Monitoring Teams.

EMERGENCY-l PLAN IMPLMENTING-PROtEDURESi EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION

  • Page 13 of 28 (a) The Site Radiation Protection Coordinator should inform the Emergency Coordinator that control of the field radiological monitoring teams and dose assessment has been transferred to the EOF.

(b) The Radiological Assessment Coordinator should then advise the Radiological and EOF Manager that the Radiological Assessment Group is ready to assume responsibility for offsite monitoring and dose assessment activities.

(c) The Field Team Director shou!d follow up with each Team and advise them that all further communications should be conducted with the EOF.

(d) Transfer of responsibility.should be recorded in both the TSC and EOF Logs.

3.5 DOSE PROJECTION ACTIVITIES (1) Until the TSC is activated, the Operations Shift Manager/Supervisor, as the Emergency Coordinator, is responsible for assuring dose projections by the on-duty shift chemist are performed.

(a) The results of these projections will normally be summarized for the Site Radiation Protection Coordinator as part of the initial briefing.

(2)

Until the EOF, is activated, the Site Radiation Protection Coordinator and/or the Operations Shift Manager/Supervisor are responsible for performing dose

. projections.

(a)'

The results of these projections will normally be summarized for the Radiological Assessment Coordinator as part of the initial briefing.

(3) Dose projection calculations will be" performed by the MIDAS Operator using

3) D os e pro j i onI b performi~I one of the following methodologies:

(a) MIDAS computer, MIDAS Instruction Manual User's Guide.

(b) 'MIDAS Backup on the Personal Computer:-'

(c) MIDAS Laptop Personal Computer.

(4) Dose projections will normally be performed in accordance with the MIDAS instructions in the MIDAS User's Guide. If MIDAS is uniavailable, the'options below will be reviewed by the Site Radiation Protection

i.a I 15 o

Wil 1o EMERGENCY PLAN IMRLMENTING PROCEDURES-. t'lri-'.-, EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION, Page 14 of 28 Coordinator/Radiological Assessment Coordinator to determine the appropriate back-up methodology.'

(a)

If real-time data collection in MIDAS is not functional, the TSC MIDAS Operator should coordinate directly with'the Control Room Communicator to determine updated radiological and meteorological parameters applicable to actual or'potential'release rates.'

(b)

If there is a loss of MIDAS in the TSC consider using the following:

(i) MIDAS Backup on the Personal Computer (ii) Use of MIDAS Laptop Computer (c)

If real-time data collection in MIDAS is not functional, the EOF MIDAS Operator should coordinate'directly with the Site Radiation Protection Coordinator to determine updated radiological and meteorological parameters applicable to actual or potential release rates.

(d)

If there is a loss of MIDAS in the EOF consider the following:

(i) Transfer of dose assessment back to the TSC (ii) Use the MIDAS Backup on the Personal Computer (iii) Use of MIDAS Laptop Computer (5)

Following review of the latest dose projection, the Site Radiation Protection Coordinator/RAC should brief the Field Team Director on the magnitude of the projected doses and the need to adjust offsite radiological monitoring activities.

(6)

If Field Team readings are significantly higher than those projected by MIDAS, consider the possibility of an' unmonitored release.

3.6 COORDINATION OF DOSE ASSESSMENT WITH THE STATE OF IOWA (1)

Upon activation of the EOF, the RAC shall verify that the "Rad Data Line" is established and operable or contact the State EOC and request that it be established.

(2)

Once established, the RAC shall communicate with the State EOC and the Benton and Linn County EOCs as necessary.

I\\_

K)~

4'

e si i

v a-.*

^

t, ;5;', ?- -,I ? *.,;_

PEMERGEN LYhPAN IMPLMENTING PROCEDL)RES
-X¢--! '

EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION, Page 15 of 28 (3)

Radiological release, dose projections, and meteorological data from the electronic MIDAS print out shall be provided to the State in order for the State to conduct dose assessment and projection activities..

(4)

The RAC shall request the State's dose projection results as they become available.

3.7 DATA RECORDING AND TREND ANALYSIS FROM THE TSC (1)

The Site Radiation Protection Coordinator should initiate and ensure conduct of trend analysis.

(a)

Parameters of interest include KAMAN System Effluent Monitor readouts, analyses conducted of effluent stream particulate filters and iodine cartridges, meteorological data, ARM levels and Containment High Range Radiation Monitor levels.

(b)

ARM and Containment High Range RadiationMonitor'levels are of dual importance due to their direct impact on response-activities within the plant and their significance with respect to determining the quantity of

  • radioactive material potentially available for release offsite.

(2)

An estimate of fuel failure can be determined by direction found in the PASAPs.

(3)

An estimate of the potential release rate can be determined by using the PASAPs.

(4)

The Site Radiation Protection Coordinator should evaluate the trending plot periodically to determine if any significant trends'are apparent.

(5)

The Emergency Coordinator and the Radiological Assessment Team should

'be periodically advised of the current radiological status, significant trends, and potential implications.

(a)

The SRPC should ensure to periodically inform representatives of the, State and Federal Government of the current radiological status,

'significant trends, and potential implications (prior to operation of the EOF).

I zi-EMERGENCY PLANIMPLMENTING PROCEDURES.

EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 16 of 28

..~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

3.8 DATA RECORDING AND TREND ANALYSIS FROM THE EOF (1) The Radiological Assessment Coordinator or his designee should trend the following information::

(a) Projected TEDE and Thyroid dose rates at the following locations:

(i) Site Boundary (ii) Two Miles (iii) Five Miles (iv)Ten Miles-(v) Greater than ten miles (vi) Location(s) of peak Whole Body and Thyroid dose rates if other than at one of the above locations.

(b) Containment High Range Radiation Monitors levels for both the Drywell V

and Torus (2) An estimate of fuel failure can be determined by using the PASAPs.

(3) An estimate of the potential release rate can be determined using the PASAPs.

(4) The Radiological and EOF. Manager and the Radiological Assessment Group should be periodically advised of the current radiological status, significant trends, and potential implications.

(a) The Radiological and EOF Manager should periodically inform the EOF staff and representatives of local, State and Federal governments of the current radiological status, significant trends, and potential implications.

(b) The Field Team Director should ensure that the Offsite Radiological Monitoring Teams are provided updated information periodically.

(5) The trending of offsite doses can be utilized as an estimation of integrated dose(s) to the general public throughout the course of the event.

I X

P-EMERGENCYPAN IMPLMENTINe'PROCEDURES EPIP 3.3

-'~~~~

rA Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION,'

.2 aid!, Ho 8tj l~l J Page 17 of 28 3.9 RE-ENTRY AND FOLLOW-UP ACTIVITIES (1)

Once releases have been terminated, the Radiological and EOF Manager, Radiological Assessment Coordinator and Site Radiation Protection Coordinator should coordinate with local, State and Federal officials to identify the activities required prior to re-entry of the general public into areas that have been evacuated.

(2)

As directed by the Emergency Response and Recovery Director, the Radiological and EOF Manager should establish an environmental monitoring program as part of the Recovery Plan to more adequately quantify the impact of this release on the environment.

(a)

As a minimum, this program should include sampling and analysis of milk, surface water, vegetation, and soil in the affected area surrounding DAEC.

(b)

This program should be structured such that it complements the routine DAEC environmental sampling program.

(c)

This program should be coordinated with the State's environmental program.

4.0 RECORDS (1)

All logs forms and other pertinent information shall be maintained in accordance with EPDM 1007, (exception is for material generated during drills and exercises.)

5.0 REFERENCES

(1)

DAEC Emergency Plan (2)

Manual of Protective Action Guides and Protective Actions for Nuclear Incidents (EPA-400-R-92-001)

EMERGENCY PLAN IMPLMENTING PROCEDURE EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 18 of 28 (3) DAEC Radiological Engineering Calculation 93-022-H; dated December 17, 1993 (4) EPIP 3.2 Field Radiological Monitoring' (5) EPIP 1.2uNotification'n:

(6)

Response Technical Manual (RTM) 1996 Section G.

6.0 ATTACHMENTS-(1) -Evacuation Time Estimates (2) Attachment 2 -Wind Direction and Affected Subareas.

K)j

I;

- r " ;-

--i'-EMERGENCY RPLAN IMPLMENTIN PRO EDURE EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 19 of 28 ATTACHMENT I EVACUATION TIME ESTIMATES' (1) Select the appropriate table for the event scenario (Summer or Winter, Midweek or Weekend, Midday or Evening)'

(2) Select the section of the table corresponding to the extent of the evacuation recommendation (Within 2, 5, or 10 miles, or to the EPZ boundary).

(3) Select th6 wind range for the expected wind direction, and read across for the evacuation time estimate under-the expected weather condition for both the general population and special population (special population consists of those at hospitals, nursing homes,' and other residential care facilities).

(4) Following the tables are evacuation time estimates for two recreational events occurring annually within-the DAEC EPZ: the All-Iowa Fair and the Cedar Rapids Freedom Festival.

(5) Times'in the tables are given in hours and minutes (i.e., 03:35 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />, 35 minutes).

NOTES For' Summer or Winter' Weekend Evening times, use the Summer or. Winter Midweek Evening times,' respectively.

Summer defined as Memorial Day through Labor Day. Winter defined as Labor Day to Memorial Day.

I I

I I

I

Y Table 5.5 Evacuation imes Estimates for Scenarios 1-8 Region Subareas 1

2 3

4 5

6 7

8 Summer Summer Summer Summer Summer Summer Summer Sumrner

Weekend, Weekend Weekend Weekend Weekday Weekday Weekday Weekday Midday Midday Evening Evening Midday Midday Evening Evening Fair Poor -

Fair Poor Fair -

Poor -

Fair Poor 1

1 2:45..

245 2.45 3:00 2:45 3:15 2:45 3:15 2

1-8 5:30 545 5:15 5:45 5:45

.6:00 5:15 5:30 3

1-24 10:45 11:45 11:15 11:45 10:30 11:15 10:15 11:00 4

1,2,8 3;00 3:45 3:15-4:15 3:30 3:45 3:15 3:30 5

1,2,3 3:00 3.45 3:15 4:15 3:30 3:45 3:15 3:30 6

1,2,3,8 3:00 3:45 3:15 4:15 3:30 3:45 3:15 3:30 7

1.2,3,4 3:00 3:45 3:15 4:15 3:30 3:45:

3:15 3:30 8

1,3,4.

3:00 3:A5 3;00 4:15 3:30 3:45 3:15 3:30 9

1,3,4,5 3:15 4:00 3:15 4:00 3:30.

3:45 3:15 3:30 10 1,4.5,6 3:15 4:00 3:15 4:00 3:30 3:45 3:15 3:30

.11 1,5,6,7 3:15 4:00 3:15 4:00 3:30 345 3:15 3:30 12 1,7,8 3:00 4:00 3:00 4:00 3:45 4:00 3:30 3:45 13 1,5,6.7,17-20 4:15

.5:15 4:15 4:30 4:30 4:45.

4:00 4:15 14 1.5,6,7,18-21 4:15 5:15 4:15 4.30 4:30 4:45 4:00 4:15 15 1,7,8,18-21 4:00 5:15 4:00 4:15 4:30:

4:45' 4:00 4:15 16 1,7,8,19-22 4:00.

5:15-4:00 4:15 4:30 4:45 4:00

-4:15 17 1,7.8,9,20-22 4:00 5:45.

4:00 4:15 4:30 4:45 4:00

-4:15 18 1,2,8,9,10,21,22 4:00 5:45 400 4:15 4:30 4:45:

4:00 4:15 19 1,2,3.8-12,21,22 4:00 5:45 4:00 4:15 4:30 4:45

  • 4:00 4:15 20 1,2,3,9-13,22 4:00 5:45 4:00 4:15 4:30 4:45 4:00.

4:15 21 1,2,3,10-13 3:45 5:45 3:45 4:00 4:30 445 4:00

-4:15 22 1,2,3,4,10-14 4:30 5:45 4:30 5:00 4:45 5:00 4:30 5:00 23 1,4,5,6,15-18,23,24 9:45 10:15 9:45 10:00 7:45 8.00 7:30.

7:45

  • 24 1.5.6,7,16-19.24

.9:00 10.00 9:00 9:00 7:30 8;00 7:30 7.45 25 1,3,4,12-15,23 9:00 10:00 9:00 9:30 7:45 8:00 7:30 7:45 26 1,3,4,5,12-16,23,24 1030 11:45 11:30 11:45 10.45 11:00 10:30 10.45 27 1,3,4,5,13-17,23,24 10:45 11:45 11:15 11:45 10:45 11:00 10.30 10.45 28 1,4,5,6,14-18,23,24 10.30 11:45 11:15 11:45 10:45 11:00 10.30 10:45 cn C,,

C'.

)0-I 11)

I I

-1 3 11I ci 0

0)m Cl)

Cl,m zci

-u 0

-I m

0 m-.'-'a m.-4

-6)"%

.me ;.

m:

'se,'

-D 0 m

0 ) rCD 0-u CD CD O

,..U 0

-4' c

(

(

a.,

(

C c

-4 Table 5.6 Evacuation Times EsUmates forScenaros 9.16.

Scenarios Region Subareas 9

10 11 12 13 14 15 16 Winter Winter Winter Winter Winter Winter Winter Winter Weekend Weekend Weekend Weekend Weekday Weekday Weekday Weekday MLday M'dday Evenng Evening Mldday Midday Evening Evening Fai Poor Fair Poor Fair Poor Fair Poor 1

1 2:45 2-45 2:45 3:00 2:45 3:15 2:45 3:45 2

1-8 5:30 6:15 5:15 6:30 6:00 6:45 5:30 6:00 3

1-24 10-45 1230 9.45 14:15 1200 14:30 11:00 12:45 4

1,2,8 3:00 4:45 3:00 4:45 3:15 3:45 3:00 3:30 5

1,2,3.

3:00 4:45 3:00 4:45 3:15.

3:45.

3:00 3:30 6

1,23,8 3:00 4:45 3:00 4:45 3:15 3:45 3:00 3:30 7

1,2,3,4 3:00 4:45 3:00 4-45 3:15 3:45

. 3:00 3.30 8

1.3.4 3:00 4:45 3:00 4:45 3:15 3:45 3:00 3:30 9

1,3,4,5 3:15 5:00 3:15 5:00 3:30

.3:45 3:00 3:30 10 1.4,5,6 3:15 5:00 3:15 5:00 3:30 3:45 3:00 3:30 II 1.5,6,7 3:15 5:00 3.15 5:00 3:30 3:45 3:00 3:30 12 1,7,8 3:00 5:00 3:00 5:00

. 3:15 3:45 3:00 3:30 13 1,5,6,7,17-20 4:15

.6:30 4:15 6:30 4:30 7:00 4:00 5:15 14 156718-21 4:15 6:30 4:15 6:30 30 0 7.00

-40 5:15 1,7,8,18-21 4:00 6:00 400 800 4:30 700 4:00 5:15 16 1,7,8,19-22 4:W0 6:00 4:00 6:00 4:15 7.0 400 5:15 17.

1,7,8,920-22 400 60 400 6:00 4:15 7:00

'4:00 5:15

18.

1,28,9,10,21,22 4:00 6:00 4:00 6:00 4:15 7.00 4:00 5:15 19 1,2,3,8-12,21,22 4:00 60 4:00

'6:00 4:15 7:00 4:00 5:15 20 1,2,3,9-13,22 4:00 6:00 4:00 6:00

. 4:15 7:00 4:00 5:15 21 1,2,3,10-13 3:45 8:00 3:45 6:00

.5:00 7:00.

4:45.-.-.

5:45..

22 1,2,3,4,10-14 4:30 6:30 4:30 6:30 5:00 7:45 4:45 6-45 23 1,4,5,6,15-18,23,24 9:45 1015 9:45

  • 1015 10:30 13:00 10:00 12:45 24 1,5,6,7,16-19,24 9:00 10.00 9:00 10.00 1015

...13:00 10:00 12:30

.25 1,3,4,12-15,23 900 10.00 9:00 1000 10-.15 13:00 10:00 12:30 26 1,3A,5,12-16,23,24 10:30 12:15 10.30 12:30 11:00 13:00 115 12:45 27 1,3,4,5,13-17,23,24 10:46 1230 10:46 12:30 11WO 14.30 10:15 12:45 28 1,4,5,6,14-18,23,24 10.30 12:30 10:30 12:45 11:15 -

14:30 10.15 12:45 0

0 C',

-m C',

C..'

mC',

C) m 0

m

-1

-o m

,m a-aZ.

rnC z.b

_-a~.

0s E

. 4 f

W)

CD

'a (D0.

9 0

-Ii, 0,j.

1 Table 5.7 Evacuaon Times Estimates for Scenaro 17.

Scenarios Region Subareas 17 Weekend Even*g Fair 1

1 2:45 2

1-8 5:15 3

1-24 16:00 4

1,2.8-3:15

  • 5 1,2,3.

3:15 6

1.2,3,8 3:15 7

1,2,3,4 3:15 8

.1.3,4 '

3:00 a

1.3,4,5 3:15 10 1,4,5.6 3:15 11 1,5,6,7:

3:15 12 1,7,8 3:00 13 1,5,6.7,17-20 4:15 14 1,5.B.7,18-21 4:15 15 1,7,8,18-21 4:00 16 1,7,8,19-22 4:00 17 1,7,8,9,20-22 4:00 18 1,2,8,9,10,21,22 4:00 19 1,2,3,8-12,21,22 4:00 20 1,2,3,9-13,22 4:00 21 1,2,3,10-13 3:45 22

.1,2,3,4,10-14 4:30 23 1,4,5,6,15-18.23,24 15:45 24 1,5,6,7,16-19,24 15:30 25 1,3,4.12-15,23 15:00 26 1,3,4,5.12.16,23,24 1:00 27 1.3,4,5,13.17,23,24 16:00 28 1,4,5,6,14-18,23,24 1600 0

0 I

l 0

,CD C',

W

ti 0

--I rn 0H

l TRC to TOMel Mobltizaon - to Loading to EPZ Edge to Unbadl EPZ EPZ Edge Loading to EPZ Subarea time (hrmin.) schools tme edge TRC Load Edge to School time edge ETE I

2

.3 4

1.5

-6 7

8

9 10 I 11 12 13 14 15 16
  • 17 18.

19 20 1:00 0:20 0:15 1:30 0:30 0:30 0:30 0:30 0:15 1:30 6:50 1:00 0:20 0:15 2:15 0:45 0:30 0:45 0:30 0:15 215 8:50 1:00

'020 0:15 1:30 0:35 0:30 0:35 0:30 0:15 1:30 7.00 1:00 0.20 0:15 0:45 0:35 0:30 0:35 0:30 0:15 0:45 5:30 1:00 0:20 0:15 0:45 0:30 0:30 0:30 0:30 0:15 0:45 5:20 1:00 020 0:15 1:45 0:35 0:30 0:35 0:30 0:15 1045 7:30 1:00 020 015 200 0:40 0:30 0:40 0:30 0:15 2:00 8:10 1:00 0 20 0:15

.1:45 0:40 0:30 0:40 0:30 0:15 1:45.

7:40 1:00 0 20

-0:15 0:45 0:40 0:30 0:40 0:30 0:15 0:45 5:40 0

.CD

.CD Co)C/)

z 0.

-I

-I m

C)

H 0

.,Z z

m-m-

.,z,

cir:

Ci-Co 0

21 22 1:00

- 00 0:15

-0:45 025 0:30-0:25 -

0:30-23 1:00 020 0:15 1:30 --- 0:35

- 0:30 0:35 0:30 24 1:00 1 0 20 0:15 1:45 0:35 0:30 0:35 0:30 0:15 0:45 5:10 0:15 1:30 7:00 0:15 1:45 7:30 W)

( D

-0 CD CD

-u CD)

K CD) 0,

I I

Table 5.11. IEvacuation time estimates for schools in winter poor weather (based on scenario-14).

1st Trip 2nd ip Travm Trarel EPZ TRC to Travel Mobilization to Loading to EPZ Edge to Unload/

EPZ EPZ Edge Loading to EPZ Subarea time (hrmin.) schools time edge TRC Load Edge to School time edge ETE 2.12.-

2. ;

4 1:00.

0:20 0:15 2:00 0:30 0:30.

0:30 0:30 0:15 1:30 7:20 5

1:00 0:20 0:15 2:30 0:45

.0:30 0:45 0:30 0:15 2:15 9:05 6

7 1:00 0:20 0:15 2:00 0:35 0:30 0:35 0:30 0:15 1:30 7:30 8

9 1:00 0:20 0:15 1:15 0:35 0:30 0:35 0:30 0:15 0:45 5:45 10 11 12 1:00 0:20 0:15 1:15 0:30 0:30 0:30 0:30 0:15 0:45 5:50 13 14 1:00 0 20 0:15 2:00 0:35 0:30 0:35 0:30 0:15 1:45 7:45 15 1:00 0:20 0:15 2:30.

0:40 0:30 0:40 0:30 0:15 2:00 8:40 16 1:00 0 20 0:15 2:15 0:40 0:30 0:40 0:30 0:15 1:45 8:10 17

18.

1:00 0:20 0:15 1:15-0:40 0:3 0:40 0:30 0:15 0:45 6:10 19 20 21 22 1:00' 020 0:15 1:15 025 0:30 0:25 0:30 0:15 0:45 5:40 23 1:00 0:20 ' 0:15 1:45 0:35 0:30 0:35 0:30 0:15 1:30 7:15 24 1:00 0:20 0:15 2.15 0:35 0:30 0:35 0:30 0:15 1:45 8:00 0

0 C')

m C/,

C')

mzH z

-0

-a

.0H m

m C)

H 0z m

m mzC) z

-a mz-4 z

6) 0-m0C mx C,,

m

-0

u m-03

.D co 4

(D

-U 0

-h t3.

I.

4 C

C

(

p.

9

(

C C

IC Table 5.12 Evacuation time estimates for the evacuation of health-related special facilities under fair weather conditions.

Tavel to EPZ RC to Evacuation Mobliization Travel to Loading EPZ Edge to Unioad/

EPZ Trip time (hrmin.)

facility time edge RC Load Edge Trip Time 1

1:00 0:45.

0:30 2:00 1:15 0:30 1:00

'7:00 2

0:15 0:30 0:15 0:15 0:30 1:00 2.45 3

0:15 0:30 0:15 0:15 0:30 1:00 2:45 4

0:15 0:30 0:15 0:15 0:30 1:00 2:45 5

0:15 0:30 0:15 0:15 0:30 1:00 2:45 18:00-Table 5.13 Evacuation time estimates for the evacuation of healhrelated special facilities under poor weather conditions.

.. I

.0 rA I

A

, 4

-4 CA 0

I Ia 0i

.0 CD, C/,mC/,

Co mz z

0 Hm C)

H Z

C)Hn m

G) z

-o z

-o Ii'

. -'1 7

C)

-U C) m C

Co Tiravel to EPZ RC to Evacuation Mobilizaton Tavel to Loading EPZ Edge to Unload/

EPZ Trip time (hrmin.)

facility time edge RC Load Edge Trip Time 1

1:15 0:45 0:30 2:30 1:30 0:30 1:15 8:45 2

0:15 0:30 0:30 0:30 0:30 1:15 3:30 3

0:15 0:30 0:30 0:30 0:30 1:15 3:30 4

0:15 0:30 0:30 0:30 0:30 1:15 3:30 5

0:15 0:30 0:30 0:30 0:30 1:15 3:30.

22:45 a)

CD

-o (a

CD 11 00

EMERGENCY PLAN IMPLMENTING EPIP 3.3

..4 -t t.

er

. si s !

. e is i -l i c

a i

i S \\;,

R e v. 2 1 DOSE ASSESSMENT AND PROTECTIVE ACTION

_________________________________J Page 26 of 28 ATTACHMENT 1 (Cont)

EVACUATION TIME ESTIMATES The evacuation time estimates for the Cedar Rapids Freedom Festival consider an evacuation of the general population within the entire DAEC Emergency Planning Zone (Subareas 1-24) this event is in progress.

Cedar Rapids Freedom Festival: 11:15

b -~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

t-EMERGENCY

.LAt4 MPLMENTING ROCEDURES r

EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 27 of 28 A1TACHMENT 2 WIND DIRECTION and AFFECTED SUBAREAS Wind direction and affected subarea populations for the DAEC EPZ (based on Table 5.2 from the Evacuation Time Estimate Study report). -

Subareas tropulatiowy Wind (degrees) 0-2 5 5-10.

10-EPZ Total Direction Miles

- Miles

- -- - Miles -

edge Population N

(348.76-11.25) 1 4,5,6 15,16,17,18 23,24 (124,968)

NNE NE ENE (11.26-33.75)

(33.76-56.25)

(56.26-78.75)

(1,134) 1 (1,134) 1 (1,134) 1 (1,134) 1*

(1,134) 1 (1,134)

(1,781) 5,6,7 (5,491) 5,6,7 (5,491) 5,6,7]

(5,491) 7,8 (1,711) 7,8 (1,711).

(64,839)

-16,17,18,19 (35,237) 17,18,19,20 (4,065) 18,19,20,21 (2,814) 18,19,20,21

': (2,814) 19,20,21,22 (2,679)

(57,214) 24 (22,140)

(64,002)

(10,690)

(9,439)

E (78.76-101.25)

ESE (101.26-123.75)

SE (123.76-146.25)

SSE (146.26-168.75)

S (168.76-191.25)

SSW (191.26-213.75)

SW (213.76-236.25)

WSW (236.26-258.75)

W (258.76-281.25)

WNW (281.26-303.75)

NW (303.76-326.25)

NNW (326.26-348.75)

1.

7,8 9,20,21,22 (1,134)

(1,711)

(4,721) 1 2,8 9,10,21,22 (1,134)

(559)

(4,758) 1 2,3,8

'9,10,11,12,21,22 (1,134)

(1,262)

(5,744) 1 2,3

'9,10,11,12,13,22 (1,134)

(1,019)

(5,710) 1

'2,3 10,11,12,13 (1,134)

-(1,109)

(2,097) 1

2,3,4 10,'11,12,13,14 '

(1,134)..

(3,523)

(37,057)

(5,659)

-(5,524)

(7,566)

(6,451)

(8,140)

(7,863)

(4,250)

'(41,714) 1 '

3,4 (1,134)

(3,207) 1

.3,4,5 (1,134)

(7,160) 1 3,4,5 (1,134)

(7,160) 1 4,5,6 (1,134)

(7,160) 12,13,14,15 (66,340) 12,13,14,15,16

(97,880) 13,14,15,16,17 (99,017) 14,15,16,17,18 (99,790)

23 (35,074) 23,24 (57,214) 23,24.

(57,214) 23,24!

(57,214)

(105,755)

(163,388)

(164,525)

(164,674)

.-,EMERGENCY PLAN IMPLMENTING PROCEDURES

EPIP 3.3 Rev. 21 DOSE ASSESSMENT AND PROTECTIVE ACTION Page 28 of 28 ATTACHMENT 3.

WIND DIRECTION AND AFFECTED SUBAREAS

<<<<<<<<<<<<<<<<<<<<<<<<<< MILES OUT >>>>>>>>>>>>>>>>>

Wind Direction 0-2 2-5 5-10.

10 - EPZ N (348.76-11.25) 1 4,5,6 15,16,17,18 23, 24 NNE (11.26-33.75) 1 5, 6, 7 16,17,18,19 24 NE (33.76 - 56.25) 1 5, 6, 7 17, 18, 19, 20 ENE (56.26-78.75) 1 5,6,7 18,19,20,21 E (78.76-101.25) 1 7,8 18,19,20,21 ESE (101.26-123.75) 1 7,8 19,20,21,22 SE (123.76-146.25) 1 7, 8 9, 20, 21, 22 SSE (146.26 - 168.75) 1 2, 8 9,10, 21, 22 S (168.76-191.25) 1 2,3,8 9, 10, 11, 12,21,22 SSW (191.26-213.75) 1 2, 3 9,10,11,12,13,22 SW (213.76-236.25) 1 2,3 10,11, 12, 13 WSW (236.26-258.75) 1 2, 3,4 10,11,12,13,14 W (258.76-281.25) 1 3, 4 12,13,14,15 23 WNW (281.26-303.75) 1 3,4,5 12,' 13,14,15, 16 23, 24 NW (303.76-326.25) 1 3, 4, 5 13,14,15, 16,17 23, 24 NNW (326.26-348.75) 1 4, 5, 6 14, 15,16,17,'18 23, 24

)