Text

D, uke U0Power.

A Duke Energy Company D.M. JAMIL Vice President Duke Power Catawba Nuclear Station 4800 Concord Rd. / CN01 VP York, SC 29745-9635 803 831 4251 803 831 3221 fax January 12, 2004 U.S. Nuclear Regulatory Commission ATTENTION:

Document Control Desk Washington, D.C. 20555-0001

Subject:

Duke Energy Corporation Catawba Nuclear Station Unit 2 Docket No.: 50-414 Core Operating Limits Report (COLR)

Catawba Unit 2 Cycle 13, Revision 23 Attached, pursuant to Catawba Technical Specification 5.6.5, is an information copy of the Core Operating Limits Report for Catawba Unit 2 Cycle 13 revision 23. The COLR revision is based on Amendment No. 204 to Operating License NPF-52.

This letter and attachment do not contain any new commitments.

Please direct any questions or concerns to George Strickland at (803) 831-3585.

Sincerely, D. M. Jamil Attachment

~OD) www. duke-energy. corn

U. S. Nuclear Regulatory Commission January 12, 2004 Page 2 xc w/att: L. A. Reyes, Regional, Administrator USNRC, Region II S. E. Peters, NRR Project Manager (CNS)

USNRC, ONRR E. F. Guthrie Senior Resident Inspector (CNS)

r CNEI-0400-25 Page I of 34 Revision 23 Catawba Unit 2 Cycle 13 Core Operating Limits Report Revision 23 January 2004 Duke Power Company Date

//6/zoo, Prepared By:

Checked By:

Checked By:

Approved By:

24K . Time P

1 /6/-200 V I I-II 2-o 4.

QA Condition I The information presented in this report has been prepared and issued in accordance with Catawba Technical Specification 5.6.5.

CNEI-0400-25 Page 2 of 34 Revision 23 INSPECTION OF ENGINEERING INSTRUCTIONS

&"*W. f. 4JA4 Inspection Waived By:

Date:

1107 120oo

(§ponsol) 7 CATAWBA Inspection Waived MCE (Mechanical & Civil) wit Inspected By/Date:

RES (Electrical Only)

&O, Inspected By/Date:

RES (Reactor)

SO Inspected By/Date:

MOD rip Inspected By/Date:

Other (

)

[I Inspected By/Date:

OCONEE Inspection Waived MCE (Mechanical & Civil)

Inspected By/Date:

RES (Electrical Only)

Inspected By/Date:

RES (Reactor)

Inspected By/Date:

MOD i.]

Inspected By/Date:

Other ( _)

Inspected By/Date:

MCQUIRE Inspection Waived MCE (Mechanical & Civil)

L Inspected By/Date:

RES (Electrical Only)

Inspected By/Date:

RES (Reactor)

Cl Inspected By/Date:

MOD

[!

Inspected By/Date:

Other (

)

11 Inspected By/Date:

CNEI-0400-25 Page 3 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report IMPLEMENTATION INSTRUCTIONS FOR REVISION 23 Revision 23 of the Catawba Unit 2 COLR must be implemented concurrent with the implementation of Amendment No. 204 to Operating License NPF-52. This Technical Specification change relocates the minimum RCS flow and other parameters to the COLR.

CNEI-0400-25 Page 4 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report REVISION LOG Revision Revisions 1-13 Revision 14 Revision 15 Revision 16 Revision 17 Revision 18 Revision 19 Revision 20 Revision 21 Revision 22 Revision 23 Effective Date N/A August 1998 October 1998 December 1998 February 2000 February 2001 September 2001 September 2001 July 2002 February 2003 January 2004 Pages Affected N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A All (except Appendix A)

COLR C2C06 - C2C09 C2CIO COLR C2C10 COLR rev 1 C2CIO COLR rev 2 C2ClI COLR C2Cl I COLR rev I C2C12 COLR C2C12 COLR rev I C2C12 COLR rev 2 C2C13 COLR C2C 13 COLR rev I

CNEI-0400-25 Page 5 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report I

INSERTION SHEET FOR REVISION 23 Remove pages Pages 1-30 Insert Rev. 23 pages Pages 1-34 Appendix A contains power distribution monitoring factors used in Technical Specification Surveillance. Appendix A is only included in the COLR copy sent to the NRC.

r CNEI-0400-25 Page 6 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 1.0 Core Operating Limits Report This Core Operating Limits Report (COLR) has been prepared in accordance with the requirements of Technical Specification 5.6.5. The Technical Specifications that reference this report are listed below:

TS COLR COL Section Technical Specifications COLR Parameter Section R

Page 2.1.1 Reactor Core Safety Limits RCS Temperature and Pressure 2.1 1.0 Safety Limits 3.1.1 Shutdown Margin Shutdown Margin 2.2 10 3.1.3 Moderator Temperature Coefficient MTC 2.3 12 3.1.4 Rod Group Alignment Limits Shutdown Margin 2.2 10 3.1.5 Shutdown Bank Insertion Limit Shutdown Margin 2.2 10 Rod Insertion Limits 2.4 12 3.1.6 Control Bank Insertion Limit Shutdown Margin 2.2 10 Rod Insertion Limits 2.5 12 3.1.8 Physics Tests Exceptions Shutdown Margin 2.2 10 3.2.1 Heat Flux Hot Channel Factor FQ 2.6 16 AFD 2.8 23 OTAT 2.9 26 Penalty Factors 2.6 16 3.2.2 Nuclear Enthalpy Rise Hot Channel FAH 2.7 22 Factor Penalty Factors 2.7 22 3.2.3 Axial Flux Difference AFD 2.8 23 3.3.1 Reactor Trip System Instrumentation OTAT 2.9 26 OPAT 2.9 26 3.3.9 Boron Dilution Mitigation System Reactor Makeup Water Flow Rate 2.10 28 3.4.1 RCS Pressure, Temperature and RCS Pressure, Temperature and 2.11 28 Flow limits for DNB Flow 3.5.1 Accumulators Max and Min Boron Conc.

2.12 28 3.5.4 Refueling Water Storage Tank Max and Min Boron Conc.

2.13 28 3.7.15 Spent Fuel Pool Boron Concentration Min Boron Concentration 2.14 30 3.9.1 Refueling Operations - Boron Min Boron Concentration 2.15 30 Concentration 3.9.2 Refueling Operations -Nuclear Reactor Makeup Water Flow Rate 2.16 30 Instrumentation 5.6.5 Core Operating Limits Report Analytical Methods 1.1 7

(COLR)

The Selected License Commitments that reference this report are listed below:

SLC 1

COLR COLR Section Selected Licensing Commitment COLR Parameter Section Page 16.7-9.3 Standby Shutdown System Standby Makeup Pump Water 2.17 31 Supply I

16.9-11 Boration Systems ater Borated Water Volume and Conc.

2.18 31 Source - Shutdown for BAT/RWST 16.9-12 Boration Systems - Borated Water Borated Water Volume and Conc.

2.19 32 1Source - Operating for BAT/RWST I

CNEI-0400-25 Page 7 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 1.1 Analytical Methods The analytical methods used to determine core operating limits for parameters identified in Technical Specifications and previously reviewed and approved by the NRC are as follows.

1. WCAP-9272-P-A, "WESTINGHOUSE RELOAD SAFETY EVALUATION METHODOLOGY," (I Proprietary).

Revision 0 Report Date: July 1985 Not Used for C2C13

2. WCAP-10054-P-A, "Westinghouse Small Break ECCS Evaluation Model using the NOTRUMP Code, " (V Proprietary).

Revision 0 Report Date: August 1985

3. WCAP-10266-P-A, "THE 1981 VERSION OF WESTINGHOUSE EVALUATION MODEL USING BASH CODE", (IV Proprietary).

Revision 2 Report Date: March 1987 Not Used for C2C13

4. WCAP-12945-P-A, Volume I and Volumes 2-5, "Code Qualification Document for Best-Estimate Loss of Coolant Analysis," (W Proprietary).

Revision: Volume I (Revision 2) and Volumes 2-5 (Revision 1)

Report Date: March 1998

5. BAW-10168P-A, "B&W Loss-of-Coolant Accident Evaluation Model for Recalculating Steam Generator Plants," (B&W Proprietary).

Revision I SER Date: January 22, 1991 Revision 2 SER Dates: August 22, 1996 and November 26, 1996.

Revision 3 SER Date: June 15, 1994.

Not Used for C2C13

CNEI-0400-25 Page 8 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 1.1 Analytical Methods (continued)

6. DPC-NE-3000PA, "Thermal-Hydraulic Transient Analysis Methodology," (DPC Proprietary).

Revision 3 SER Date: September 24,2003

7. DPC-NE-3001PA, "Multidimensional Reactor Transients and Safety Analysis Physics Parameter Methodology," (DPC Proprietary).

Revision 0 Report Date: November, 1991, republished December 2000

8. DPC-NE-3002A, "UFSAR Chapter 15 System Transient Analysis Methodology".

Revision 4 SER Date: April 6, 2001

9. DPC-NE-2004P-A, "Duke Power Company McGuire and Catawba Nuclear Stations Core Thermal-Hydraulic Methodology using VIPRE-Ol," (DPC Proprietary).

Revision 1 SER Date: February 20, 1997

10. DPC-NE-2005P-A, "Thermal Hydraulic Statistical Core Design Methodology," (DPC Proprietary).

Revision 3 SER Date: September 16, 2002 I1. DPC-NE-2008P-A, "Fuel Mechanical Reload Analysis Methodology Using TACO3," (DPC Proprietary).

Revision 0 SER Date: April 3, 1995

12. DPC-NE-2009-P-A, "Westinghouse Fuel Transition Report," (DPC Proprietary).

Revision 2 SER Date: December 18, 2002

13. DPC-NE-1004A, "Nuclear Design Methodology Using CASMO-3/SIMULATE-3P."

Revision I SER Datc: April 26, 1996

CNEI-0400-25 Page 9 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 1.1 Analytical Methods (continued)

14. DPC-NF-201 OA, "Duke Power Company McGuire Nuclear Station Catawba Nuclear Station Nuclear Physics Methodology for Reload Design."

Revision 2 SER Date: June 24,2003

15. DPC-NE-201 IPA, "Duke Power Company Nuclear Design Methodology for Core Operating Limits of Westinghouse Reactors," (DPC Proprietary).

Revision I SER Date: October 1, 2002

CNEI-0400-25 Page 10 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 2.0 Operating Limits The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the following subsections. These limits have been developed using NRC approved methodologies specified in Section 1.1.

2.1 Reactor Core Safety Limits (TS 2.1.1)

The Reactor Core Safety Limits are shown in Figure 1.

2.2 Shutdown Margin - SDM (TS 3.1.1, TS 3.1.4, TS 3.1.5, TS 3.1.6, TS 3.1.8) 2.2.1 For TS 3.1.1, shutdown margin shall be greater than or equal to 1.3% AK/K in mode 2 with Keff < 1.0 and in modes 3 and 4.

2.2.2 For TS 3.1.1, shutdown margin shall be greater than or equal to 1.0% AK/K in mode 5.

2.2.3 For TS 3.1.4, shutdown margin shall be greater than or equal to 1.3% AK/K in mode I and mode 2.

2.2.4 For TS 3.1.5, shutdown margin shall be greater than or equal to 1.3% AK/K in mode 1 and mode 2 with any control bank not fully inserted.

2.2.5 For TS 3.1.6, shutdown margin shall be greater than or equal to 1.3% AK/K in mode 1 and mode 2 with Keff > 1.0.

2.2.6 For TS 3.1.8, shutdown margin shall be greater than or equal to 1.3% AK/K in mode 2 during Physics Testing.

CNEI-0400-25 Page 11 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report Figure I Reactor Core Safety Limits Four Loops in Operation 670 DO NOT OPERATE IN TilIS AREA 660 6 40 0 620 0X$

610 600 5830ACCEPTABLE 0.0 0.2 0.4 0.6 0.8 1.0 1.2 cli Fraction of Rated Thermal Power

CNEI-0400-25 Page 12 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 2.3 Moderator Temperature Coefficient - MTC (TS 3.1.3) 2.3.1 The Moderator Temperature Coefficient (MTC) Limits are:

The MTC shall be less positive than the upper limits shown in Figure 2. The BOC, ARO, HZP MTC shall be less positive than 0.7E-04 AK/K/IF.

The EOC, ARO, RTP MTC shall be less negative than the -4.1E-04 AK/K/0F lower MTC limit.

2.3.2 The 300 ppm MTC Surveillance Limit is:

The measured 300 PPM ARO, equilibrium RTP MTC shall be less negative than or equal to -3.2E-04 AK/K/IF.

2.3.3 The 60 PPM MTC Surveillance Limit is:

The 60 PPM ARO, equilibrium RTP MTC shall be less negative than or equal to

-3.85E-04 AK/K/0F.

Where:

BOC = Beginning of Cycle (burnup corresponding to most positive MTC)

EOC = End of Cycle ARO = All Rods Out HZP = Hot Zero Thermal Power RTP = Rated Thermal Power PPM = Parts per million (Boron) 2.4 Shutdown Bank Insertion Limit (TS 3.1.5) 2.4.1 Each shutdown bank shall be withdrawn to at least 226 steps. Shutdown banks are withdrawn in sequence and with no overlap.

2.5 Control Bank Insertion Limits (TS 3.1.6) 2.5.1 Control banks shall be within the insertion, sequence, and overlap limits shown in Figure 3. Specific control bank withdrawal and overlap limits as a function of the fully withdrawn position are shown in Table 1.

CNEI-0400-25 Page 13 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report I

Figure 2 Moderator Temperature Coefficient Upper Limit Versus Power Level 1.0 I

1-0 I-.

0.9 0.8 P-4 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0

10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power NOTE: Compliance with Technical Specification 3.1.3 may require rod withdrawal limits.

Refer to the Unit 2 ROD manual for details.

CNEI-0400-25 Page 14 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report Figure 3 Control Bank Insertion Limits Versus Percent Rated Thermal Power Fully Withdrawn (Maximum = 231) 231 220 200

- 180

= 160

o. 140 c-120

.2 c 0 100 r-

  • 0 80

-E

~E60 0

W 40 20 0

0 10 20 30 40 50 60 70 80 90 100 Percent of Rated Thernal Power The Rod Insertion Limits (RIL) for Control Bank D (CD), Control Bank C (CC), and Control Bank B (CB) can be calculated by:

Bank CD RIL = 2.3(P) -69 {30< P <* I00}

Bank CCRIL = 2.3(P) + 47 {0 < P < 80}

Bank CBRIL = 2.3(P) + 163 {O < P < 29.6}

where P = %Rated Thermal Power NOTE: Compliance with Technical Specification 3.1.3 may require rod withdrawal limits.

Refer to the Unit 2 ROD manual for details.

CNEI-0400-25 Page 15 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report Table 1 Control Bank Withdrawal Steps and Sequence Fully Withdrawn at 222 Steps Control Control Control Control BankA BankB BankC BankD Fully Withdrawn at 223 Steps Control Control Control Control Bank A Bank B BankC BanklD O Stan 0

0 0

116 0 Star 0

0 222 Stop 106 0

0 222 116 0 Start 0

222 222 Stop 106 0

222 222 116 0 Start 222 222 222 Stop 106 Fully Withdrawn at 224 Steps Control Control Control Control BankA BankB BankC BanklD O Start 0

0 0

116 OStart 0

0 223 Stop 107 0

0 223 116 0 Start 0

223 223 Stop 107 0

223 223 116 0 Start 223 223 223 Stop 107 Fully Withdrawn at 225 Steps Control Control Control Control BankA BankB BankC BankfD O Stan 0

0 0

116 0 Start 0

0 224 Stop 108 0

0 224 116 0 Start 0

224 224 Stop 108 0

224 224 116 0 Start 224 224 224 Stop 108 Fully Withdrawn at 226 Steps Control Control Control Control BankA BankB BankC BankD O Start 0

0 0

116 OStan 0

0 225 Stop 109 0

0 225 116 0 Start 0

225 225 Stop 109 0

225 225 116 0 Start 225 225 225 Stop 109 Fully Withdrawn at 227 Steps Control Control Control Control Bank A Bank B Bank C Bank D O Start 0

0 0

116 0 Start 0

0 226 Stop 110 0

0 226 116 0 Start 0

226 226 Stop 110 0

226 226 116 0 Start 226 226 226 Stop 110 Fully Withdrawn at 228 Steps Control Control Control Control BankA BankB BankC BankD O Start 0

0 0

116 OStan 0

0 227 Stop III 0

0 227 116 0 Stan 0

227 227 Stop III 0

227 227 116 0 Start 227 227 227 Stop III Fully Withdrawn at 229 Steps Control Control Control Control BankA Bank B Bank C Bank D O Start 0

0 0

116 OStart 0

0 229 Stop 113 0

0 229 116 0 Start 0

229 229 Stop 113 0

229 229 116 0 Stan 229 229 229 Stop 113 O Start 0

0 0

116 0 Start 0

0 228 Stop 112 0

0 228 116 0 Start 0

228 228 Stop 112 0

228 228 116 0 Start 228 228 228 Stop 112 Fully Withdrawn at 230 Steps Control Control Control Control Bank A Bank B Bank C Bank D O Stan 0

0 0

116 0 Start 0

0 230 Stop 114 0

0 230 116 OStart 0

230 230 Stop 114 0

230 230 116 0 Stan 230 230 230 Stop 114 Fully Withdrawn at 231 Steps Control Control Control Control Bank A Bank B Bank C Bank D O Start 0

0 0

116 OStart 0

0 231 Stop 115 0

0 231 116 0 Start 0

231 231 Stop 115 0

231 231 116 OStart 231 231 231 Stop 115

CNEI-0400-25 Page 16 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 2.6 Heat Flux Hot Channel Factor - FQ(X,Y,Z) (TS 3.2.1) 2.6.1 FQ(X,Y,Z) steady-state limits are defined by the following relationships:

F RTP *K(Z)/P for P > 0.5 F RTP *K(Z)/0.5 for P < 0.5

where, P = (Thermal Power)/(Rated Power)

Note: The measured FQ(XY,Z) shall be increased by 3% to account for manufacturing tolerances and 5% to account for measurement uncertainty when comparing against the LCO limits. The manufacturing tolerance and measurement uncertainty are implicitly included in the FQ surveillance limits as defined in COLR Sections 2.6.5 and 2.6.6.

2.6.2 FRTP = 2.50 x K(BU) 2.6.3 K(Z) is the normalized FQ(X,Y,Z) as a function of core height. K(Z) for MkBW fuel is provided in Figure 4, and the K(Z) for Westinghouse RFA fuel is provided in Figure 5.

2.6.4 K(BU) is the normalized FQ(X,Y,Z) as a function of burnup. K(BU) for MkBW, Westinghouse RFA and NGF fuel is 1.0 at all burnups.

The following parameters are required for core monitoring per the Surveillance Requirements of Technical Specification 3.2.1:

FD(XYZ)

  • MQ(XY,Z) 2.6.5

[FQ(XYZ)]OP =

UMT

  • TILT where:

[FQ (X,Y,Z)]OP = Cycle dependent maximum allowable design peaking factor that ensures that the FQ(X,Y,Z) LOCA limit is not exceeded for operation within the AFD, RIL, and QPTR limits.

[F' (X,Y,Z)]0o includes allowances for calculational and measurement uncertainties.

I-CNEI-0400-25 Page 17 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report F~ (X,Y,Z)=

Design power distribution for FQ. FD (X,Y,Z) is provided in Table 4, Appendix A, for normal operating conditions and in Table 7, Appendix A for power escalation testing during initial startup operation.

MQ(X,Y,Z) =

Margin remaining in core location XY,Z to the LOCA limit in the transient power distribution. MQ(X,Y,Z) is provided in Table 4, Appendix A for normal operating conditions and in Table 7, Appendix A for power escalation testing during initial startup operation.

UMT = Total Peak Measurement Uncertainty. (UMT = 1.05)

MT = Engineering Hot Channel Factor. (MT= 1.03)

TILT = Peaking penalty that accounts for allowable quadrant power tilt ratio of 1.02. (TILT = 1.035) 2.6.6

[FQ(X,Y,Z)]

=

FQ(XYZ)

  • MC(XYZ)

UMT

  • TILT where:

LF(X,y,Z)]RpS Cycle dependent maximum allowable design peaking factor that ensures that the FQ(X,Y,Z) Centerline Fuel Melt (CFM) limit is not exceeded for operation within the AFD, RIL, and QPTR limits. [FL(XY,Z)]RPS includes allowances for calculational and measurement uncertainties.

F D(X,Y,Z)

=

MC(X,Y,Z)

=

Design power distributions for FQ. FD(X,Y,Z) is provided in Table 4, Appendix A for normal operating conditions and in Table 7, Appendix A for power escalation testing during initial startup operations.

Margin remaining to the CFM limit in core location XY,Z from the transient power distribution. MC(X,Y,Z) is provided in Table 5, Appendix A for normal operating conditions and in Table 8, Appendix A for power escalation testing during initial startup operations.

UMT = Measurement Uncertainty (UMT = 1.05)

CNEI-0400-25 Page 18 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report MT = Engineering Hot Channel Factor (MT = 1.03)

TILT = Peaking penalty that accounts for allowable quadrant power tilt ratio of 1.02. (TILT= 1.035) 2.6.7 KSLOPE = 0.0725 where:

KSLOPE = the adjustment to the Kj value from OTAT trip setpoint required to compensate for each 1% that FQA' (X,Y,Z) exceeds [FQA (X,Y,Z)]

2.6.8 FQ(X,Y,Z) Penalty Factors for Technical Specification Surveillances 3.2.1.2 and 3.2.1.3 are provided in Table 2.

-:, -: -7,,

CNEI-0400-25 Page 19 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report Figure 4 K(Z), Normalized FQ(XY,Z) as a Function of Core Height for MkBW Fuel 1.200 1.000 0.800 g- 0.600 0.400 0.200 0.000 (0.0, 1.00)

(6.0, 1.00)

(12.0, 1.00)

Core Height (ft)

K(Z) 0.0 1.000 6.0 1.000 12.0 1.000 I

~

~~I

. I II 0.0 2.0 4.0 6.0 Core Height (ft) 8.0 10.0 12.0

P CNEI-0400-25 Page 20 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report Figure 5 K(Z), Normalized FQ(XY,Z) as a Function of Core Height for RFA Fuel 1.200 -

(0.0, 1.00)

(6.0, 1.00)

(12.0, 1.00) 1.000 0.800 -

0.600 -

0.400 -

Core Height 0.200 (ft)

K(Z) 0.0 1.000 6.0 1.000 12.0 1.000 0.000 I

0.0 2.0 4.0 6.0 8.0 10.0 12.0 Core Height (ft)

CNEI-0400-25 Page 21 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report Table 2 FQ(X,Y,Z) and Fa,&(X,Y) Penalty Factors For Tech Spec Surveillances 3.2.1.2, 3.2.1.3 and 3.2.2.2 Burnup (EFPD) 4 12 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500 509 524 534 FQ(X,Y,Z)

Penalty Factor(%)

2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 FAII(XY)

Penalty Factor (%)

2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 Note: Linear interpolation is adequate for intermediate cycle burnups.

All cycle burnups outside the range of the table shall use a 2%

penalty factor for both FQ(X,Y,Z) and FAII(X,Y) for compliance with the Tech Spec Surveillances 3.2.1.2, 3.2.1.3 and 3.2.2.2.

CNEI-0400-25 Page 22 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 2.7 Nuclear Enthalpy Rise Hot Channel Factor - FAH(XY) (TS 3.2.2)

The FAH steady-state limits referred to in Technical Specification 3.2.2 are defined by the following relationship.

2.7.1

[FLI (X, Y)]LCO= MARP (X,Y) * [1-0 +

I * (1.0- P)]

where:

[FUEt, (X,Y)]LCO is defined as the steady-state, maximum allowed radial peak and includes allowances for calculation/measurement uncertainty.

MARP(X,Y) =

Cycle-specific operating limit Maximum Allowable Radial Peaks. MARP(XY) radial peaking limits are provided in Table 3.

Thermal Power Rated Thermal Power RRH =Thermal Power reduction required to compensate for each 1% that the measured radial peak, Fast (X,Y), exceeds the limit.

(RRH = 3.34, 0.0 < P < 1.0)

The following parameters are required for core monitoring per the Surveillance requirements of Technical Specification 3.2.2.

2.7.2

[F.LI (XY)IsURV

_ FAt1(XY)*MA,,(XY)

UMR*TILT where:

[F., (X,Y)]

= Cycle dependent maximum allowable design peaking factor that ensures that the F,,i(X,Y) limit is not exceeded for operation within the AFD, RIL, and QPTR limits.

FL, (Xy)sURv includes allowances for calculational and measurement uncertainty.

FilD (X,Y) = Design power distribution for FIl F Dl (XY) is provided in Table 6, Appendix A for normal operation and in Table 9, Appendix A for power escalation testing during initial startup operation.

T CNEI-0400-25 Page 23 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report M,,A(X,Y) =The margin remaining in core location X,Y relative to the Operational DNB limits in the transient power distribution.

MAH(X,Y) is provided in Table 6, Appendix A for normal operation and in Table 9, Appendix A for power escalation testing during initial startup operation.

UMR

= Uncertainty value for measured radial peaks. UMR is set to 1.0 since a factor of 1.04 is implicitly included in the variable MAI(XY).

TILT = Peaking penalty that accounts for allowable quadrant power tilt ratio of 1.02. (TILT = 1.035) 2.7.3 RRH =3.34 where:

RRH = Thermal Power reduction required to compensate for each 1% that the measured radial peak, F6', (X,Y) exceeds its limit. (0 < P < 1.0) 2.7.4 TRH = 0.04 where:

TRH = Reduction in OTAT K, setpoint required to compensate for each 1% that the measured radial peak, FAII(X,Y) exceeds its limit.

2.7.5 FA,&1(X,Y) Penalty Factors for Technical Specification Surveillance 3.2.2.2 are provided in Table 2.

2.8 Axial Flux Difference - AFD (TS 3.2.3) 2.8.1 The Axial Flux Difference (AFD) Limits are provided in Figure 6.

CNEI-0400-25 Page 24 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report Table 3 Maximum Allowable Radial Peaks (MARPS)

MkBW Fuel MARPs 100% Full Power Core Height Axial Peak (fI) 1.05 1.1 1.2 13 IA 1.5 1.6 1.7 1.8 1.9 2.1 3.0 3.25 0.12 1.678 1.708 1.772 1.829 1.878 1.922 1.852 1.798 1.714 1.636 1.535 1.211 1.147 1.20 1.675 1.706 1.766 1.821 1.867 1.886 1.829 1.806 1.731 1.655 1.540 1.182 1.117 2.40 1.679 1.708 1.763 1.815 1.853 1.841 1.786 1.769 1.711 1.655 1.557 1.168 1.106 3.60 1.682 1.709 1.760 1.804 1.812 1.797 1.743 1.722 1.669 1.619 1.556 1.202 1.131 4.80 1.684 1.708 1.754 1.792 1.766 1.750 1.699 1.681 1.630 1.581 1.516 1.232 1.186 6.00 1.686 1.708 1.745 1.761 1.715 1.703 1.654 1.638 1.590 1.544 1.476 1.206 1.156 7.20 1.686 1.704 1.733 1.714 1.666 1.649 1.603 1587 1.542 1.503 1.438 1.177 1.127 8A0 1.681 1.692 1.702 1.660 1.612 1.595 1.549 1.537 1A94 1.454 1.387 1.145 1.100 9.60 1.673 1.677 1.651 1.601 1.558 1.544 1.502 1.491 IA50 1.413 1.350 1.121 1.076 10.80 1.662 1.649 1.603 1.550 1.503 1.491 1.448 1.441 IA04 1.369 1.307 1.086 1.043 12.00 1.636 1.608 1.553 1.505 1.456 1.446 1.408 IA03 1.370 1.340 1.286 1.072 1.027 RFA Fuel MARPs 100% Full Power Core Height Axial Peak (11) 1.05 1.1 12 1.3 IA 1.5 1.6 1.7 1.8 1.9 2.1 3.0 3.25 0.12 1.847 1.882 1.947 1.992 1.974 2.068 2.090 2.049 1.972 1.900 1.778 1.315 1.246 1.20 1.843 1.879 1.938 1.992 1.974 2.068 2.054 2.012 1.935 1.862 1.785 1.301 1.224 2.40 1.846 1.876 1.931 1.981 1.974 2.068 2.025 1.981 1.903 1.832 1.757 1.468 1.456 3.60 1.843 1.869 1.920 1.964 1.974 2.068 2.005 1.968 1.892 1.820 1.716 1.471 1.431 4.80 1.838 1.868 1.906 1.945 1.974 2.006 1.945 1.925 1.862 1.802 1.725 1.326 1.285 6.00 1.834 1.856 1.891 1.921 1.946 1.934 1.878 1.863 1.802 1.747 1.673 1.384 1.317 7.20 1.828 1.845 1.871 1.893 1.887 1.872 1.809 1.787 1.732 1.681 1.618 1.316 1.277 8.40 1.823 1.829 1.847 1.857 1.816 1.795 1.739 1.722 1.675 1.630 1.551 1.247 1.211 9.60 1.814 1.812 1.809 1.792 1.738 1.724 1.678 1.665 1.621 1.578 1.492 1.191 1.137 10.80 1.798 1.784 1.761 1.738 1.697 1.682 1.626 1.605 1.558 1.512 1.A30 1.149 1.097 11.40 1.789 1.765 1.725 1.684 1.632 1.614 1.569 1.557 1.510 1.466 1.392 1.113 1.060

-1 CNEI-0400-25 Page 25 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report Figure 6 Percent of Rated Thermal Power Versus Percent Axial Flux Difference Limits

(-18, 100)

A

(+10, 100)

Unacceptable Operation Unacceptable Operation 90 80 0

70 Acceptable Operation 60 50 Ce ~

(-36, 50) 1(+21, 50) 40 30

-50 40

-30

-20

-10 0

10 20 30 40 50 Axial Flux Difference (% Delta 1)

NOTE: Compliance with Technical Specification 3.2.1 may require more restrictive AFD limits. Refer to the Unit 2 ROD manual for operational AFD limits.

CNEI-0400-25 Page 26 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 2.9 Reactor Trip System Instrumentation Setpoints (TS 3.3.1) Table 3.3.1-1 2.9.1 Overtemperature AT Setpoint Parameter Values Parameter Nominal Value Nominal Tavg at RTP Nominal RCS Operating Pressure Overtemperature AT reactor trip setpoint Overtemperature AT reactor trip heatup setpoint penalty coefficient Overtemperature AT reactor trip depressurization setpoint penalty coefficient Time constants utilized in the lead-lag compensator for AT Time constant utilized in the lag compensator for AT Time constants utilized in the lead-lag compensator for Tayg Time constant utilized in the measured Tav, lag compensator fl (Al) "positive" breakpoint fl (Al) "negative" breakpoint fl(Al) "positive" slope fl(Al) "negative" slope T'< 590.8 OF P'= 2235 psig Ki = 1.1953 K2 = 0.03163/OF K3 = 0.001414/psi T = 8 sec.

x2 = 3 sec.

3 =0 sec.

¶4 = 22 sec.

¶5 = 4 sec.

6= 0 sec.

= 3.0 %Al

= -39.9%Al

= 1.525 %ATO/ %Al

= 3.9 10%ATOf0/oAl

CNEI-0400-25 Page 27 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 2.9.2 Overpower AT Setpoint Parameter Values Parameter Nominal Tavg at RTP Overpower AT reactor trip setpoint Overpower AT reactor trip penalty Overpower AT reactor trip heatup setpoint penalty coefficient Time constants utilized in the lead-lag compensator for AT Time constant utilized in the lag compensator for AT Time constant utilized in the measured Tayg lag compensator Time constant utilized in the rate-lag controller for Tavg f2(AI) "positive" breakpoint f2(Al) "negative" breakpoint f2(AI) "positive" slope f2(Al) "negative" slope Nominal Value T" <590.8 0F K 4= 1.0819 Ks = 0.02 / 'F for increasing Tavg Ks = 0.00 / 'F for decreasing Tavg KO

= 0.001 291/OF for T > T" K6 = 0.0 /0F for T < T" T = 8 sec.

T2 = 3 sec.

¶3 =0 sec.

T6 = 0 sec.

x7 = 10 sec.

=35.0%Al

= -35.0 %Al

= 7.0 %ATo/ %AI

= 7.0 %ATd %Al

CNEI-0400-25 Page 28 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 2.10 Boron Dilution Mitigation System (TS 3.3.9) 2.10.1 Reactor Makeup Water Pump flow rate limits:

Applicable Mode Limit Mode 3

< 150 gpm Mode 4 or 5

< 70 gpm 2.11 RCS Pressure, Temperature and Flow Limits for DNB (TS 3.4.1)

The RCS pressure, temperature and flow limits for DNB are shown in Table 4.

2.12 Accumulators (TS 3.5.1) 2.12.1 Boron concentration limits during modes 1 and 2, and mode 3 with RCS pressure

>1000 psi:

Parameter Limit Cold Leg Accumulator minimum boron concentration.

2,500 ppm Cold Leg Accumulator maximum boron concentration.

3,075 ppm 2.13 Refueling Water Storage Tank - RWST (TS 3.5.4) 2.13.1 Boron concentration limits during modes 1, 2, 3, and 4:

Parameter Limit Refueling Water Storage Tank minimum boron 2,700 ppm concentration.

Refueling Water Storage Tank maximum boron 3,075 ppm concentration.

7 V

CNEI-0400-25 Page 29 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report Table 4 Reactor Coolant System DNB Parameters PARAMETER

1. Indicated RCS Average Temperature
2. Indicated Pressurizer Pressure No. Operable INDICATION CHANNELS meter 4

meter 3

computer 4

computer 3

meter 4

meter 3

computer 4

computer 3

LIMITS

<592.9OF

<592.6OF

< 593.4 'F

<593.2OF

> 2219.8 psig

> 2222.1 psig

> 2215.8 psig

> 2217.5 psig

> 390,000 gpm

3. RCS Total Flow Rate

CNEI-0400-25 Page 30 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 2.14 Spent Fuel Pool Boron Concentration (TS 3.7.15) 2.14.1 Minimum boron concentration limit for the spent fuel pool. Applicable when fuel assemblies are stored in the spent fuel pool.

Parameter Limit Spent fuel pool minimum boron concentration.

2,700 ppm 2.15 Refueling Operations - Boron Concentration (TS 3.9.1) 2.15.1 Minimum boron concentration limit for the filled portions of the Reactor Coolant System, refueling canal, and refueling cavity for mode 6 conditions. The minimum boron concentration limit and plant refueling procedures ensure that the Keff of the core will remain within the mode 6 reactivity requirement of Keff <

0.95.

Parameter Limit Minimum Boron concentration of the Reactor Coolant System, the refueling canal, and the refueling cavity.

2,700 ppm 2.16 Refueling Operations - Instrumentation (TS 3.9.2) 2.16.1 Reactor Makeup Water Pump Flow rate Limit:

Applicable Mode Limit Mode 6

< 70 gpm

CNEI-0400-25 Page 31 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 2.17 Standby Shutdown System - Standby Makeup Pump Water Supply - (SLC-16.7-9.3) 2.17.1 Minimum boron concentration limit for the spent fuel pool. Applicable for modes 1, 2, and 3.

x Parameter Limit Spent fuel pool minimum boron concentration for surveillance SLC-1 6.7-9.3.

2,700 ppm 2.18 Borated Water Source - Shutdown (SLC 16.9-1 1) 2.18.1 Volume and boron concentrations for the Boric Acid Tank (BAT) and the Refueling Water Storage Tank (RWST) during Mode 4 with any RCS cold leg temperature < 2850F, and Modes 5 and 6.

Parameter Limit Boric Acid Tank minimum boron concentration 7,000 ppm Volume of 7,000 ppm boric acid solution required to maintain SDM at 680F Boric Acid Tank Minimum Shutdown Volume (Includes the additional volumes listed in SLC 16.9-11) 2000 gallons 13,086 gallons (14.9%)

NOTE: When cycle burnup is > 450 EFPD, Figure 7 may be used to determine the required Boric Acid Tank Minimum Level.

Refueling Water Storage Tank minimum boron concentration Volume of 2,700 ppm boric acid solution required to maintain SDM at 68 TF Refueling Water Storage Tank Minimum Shutdown Volume (Includes the additional volumes listed in SLC 16.9-11) 2,700 ppm 7,000 gallons 48,500 gallons (8.7%)

CNEI-0400-25 Page 32 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Limits Report 2.19 Borated Water Source - Operating (SLC 16.9-12) 2.19.1 Volume and boron concentrations for the Boric Acid Tank (BAT) and the Refueling Water Storage Tank (RWST) during Modes 1, 2, and 3 and Mode 4 with all RCS cold leg temperatures > 285 0F.

Parameter Boric Acid Tank minimum boron concentration Limit 7,000 ppm Volume of 7,000 ppm boric acid solution required to maintain SDM at 285TF Boric Acid Tank Minimum Shutdown Volume (Includes the additional volumes listed in SLC 16.9-12) 13,500 gallons 25,200 gallons (45.8%)

NOTE: When cycle burnup is > 450 EFPD, Figure 7 may be used to determine the required Boric Acid Tank Minimum Level.

Refueling Water Storage Tank minimum boron concentration 2,700 ppm Volume of 2,700 ppm boric acid solution required to maintain SDM at 285 TF Refueling Water Storage Tank Minimum Shutdown Volume (Includes the additional volumes listed in SLC 16.9-12) 57,107 gallons 98,607 gallons (22.0%)

i CNEI-0400-25 Page 33 of 34 Revision 23 Cataivba 2 Cycle 13 Core Operating Limits Report Figure 7 Boric Acid Storage Tank Indicated Level Versus Primary Coolant Boron Concentration (Valid When Cycle Burnup is > 450 EFPD)

This figure includes additional volumes listed in SLC 16.9-11 and 16.9-12 50.0 I

45.0 RCS Boron Concentration BAT Level 400°

.;-6.

§

b l

.(ppm)

(°/devel) _

0 < 300 43.0 T

i 300 <500 40.0 350

-.~~~~~~~.

r

~~~500

<700 37.0 700 < 1000 30.0

> 30.0 -

1000 < 1300 14.9 V '

v i

i' ;'"* !--1300<

2700 9.8

<,, 25.0 -.;1.

r

~

  • + i

> 2700 9.8

>Unacceptable i

< 20.0 tiOperation Acceptable Operation 15.0 -

t 50o x ' "

S 0

i X0':

,:';t

X m

S

.0 0.0 0

200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Primary Coolant Boron Concentration (ppmb)

CNEI-0400-25 Page 34 of 34 Revision 23 Catawba 2 Cycle 13 Core Operating Li mits Report Appendix A Power Distribution Monitoring Factors Appendix A contains power distribution monitoring factors used in Technical Specification Surveillance. Due to the size of the monitoring factor data, Appendix A is controlled electronically within Duke and is not included in the Duke internal copies of the COLR. The Catawba Reactor and Electrical Systems Engineering Section controls this information via-computer files and should be contacted if there is a need to access this information.

Appendix A is included in the COLR copy transmitted to the NRC.