Text

{{#Wiki_filter:P.O. Box 63 Lycorning, New York 13093 Constellation Energy Group Nine Mile Point July 23, 2003 Nuclear Station NMP1L 1748 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

SUBJECT:

Nine Mile Point Unit 1 Docket No. 50-220 Facility Operating License No. DPR-63 Submittal of Inservice Inspection Owners Activity Reports Gentlemen: Enclosures 1 through 7 contain inservice inspection owners activity reports for Nine Mile Point Unit 1 (NMP1). Some explanation relating to these reports is provided below. In accordance with the requirements of the American Society of Mechanical Engineers (ASME), Boiler and Pressure Vessel Code, Section XI (1989 Edition with no Addenda, 1992 Edition with 1992 Addenda, and 1998 Edition with no Addenda), Nine Mile Point Nuclear Station, LLC (NMPNS) conducted nondestructive examination of selected components on Nine Mile Point Unit 1 (NMP1) during the first period of the third 10-year inservice inspection (ISI) interval, which began on December 26, 1999 and was originally scheduled to end on December 25, 2002. Due to excessively high radiation levels experienced in the drywell during refueling outage sixteen (RFO16), the end date of the first inspection period was extended from December 25, 2002 to April 23, 2003, approximately four (4) months, in order for NMPNS to complete the first inspection period examinations. The extension of inspection periods is allowed by ASME Code, Section Xl, and will not alter the NMPI third ten-year ISI interval starting and ending dates of December 26, 1999, and December 25, 2009, respectively, for inservice examinations and containment inspections. The first inservice inspection period originally consisted only of RFO16, which occurred in Spring 2001. Due to the extension of the first inspection period, refueling outage seventeen (RF017), which occurred in Spring 2003, has also been included in the first inspection period. In the case of the first containment inspection period, which also originally consisted only of RFO16, refueling outage fifteen (RF015), which occurred in Spring 1999, has also been included in the first inspection period. bU-

Page 2 NMP1L 1748 By letter dated August 17, 2000, the NRC approved Relief Request RR-IWE/IWL-1 for NMP1 allowing containment inspections to be performed per the 1998 ASME Code Edition with no Addenda in lieu of the 1992 ASME Code Edition with 1992 Addenda. Therefore, while the 1992 Code Edition with 1992 Addenda was used for the RFO15 containment inspections, the 1998 Code Edition with no Addenda was used for the RFO16 and RFO17 containment inspections. By letter dated October 5, 2000, the NRC approved relief request RR-ISI-8 to utilize ASME Code Case N-532 as an alternative to the requirements of IWA-6210(c) and (d), IWA-6220, IWA-6230(b), (c), and (d), and IWA-6240(b) for preparation and submittal of inservice inspection summary reports. In accordance with requirements of ASME Code Case N-532, an Owners Activity Report Form (OAR-1) and applicable Tables were prepared and certified upon completion of RFO16. For those examination items that were re-scheduled to RFO17 as part of the first inspection period extension, additional OAR-1 forms were prepared and certified upon completion of the outage. Revision 13 to Regulatory Guide (RG) 1.147 is due to become effective on August 7, 2003. This revision approves Code Case N-532-1 with a condition that the Owners Activity Reports be submitted to the NRC within 90 days of the completion of the refueling outage. As a condition to the NRC approval of relief request RR-ISI-8, NMPNS should follow all provisions of Code Case N-532-1 with limitations (if any) specified by 10CFR50.55a. As a result of Revision 13 to RG 1.147, NMPNS is also including OAR-1 forms for RFO17, second inspection period reports (see Enclosures 6 and 7). With the exception of the examinations allowed to be deferred until the end of the inspection interval by ASME Code, Section XI, or those examinations deferred based on NRC approved relief requests, the percentage requirements for the NMP1 first inspection period have been satisfied, and this constitutes a close-out of the first inservice inspection period. Very truly yours, ager Engineerin Services BSM/AA/bjh Enclosures 1 through 7 cc: Mr. H. J. Miller, NRC Regional Administrator, Region I Mr. G. K. Hunegs, NRC Senior Resident Inspector Mr. P. S. Tam, Senior Project Manager, NRR (2 copies)

Niagara NMohawlC Niagara Mohawk Power Corporation 300 Erie Boulevard West Syracuse, New York 13252 ENCLOSURE 1 THIRD INSERVICE INSPECTION INTERVAL FIRST INSERVICE INSPECTION PERIOD 2001 OWNER'S ACTIVITY REPORT FOR INSERVICE EXAMINATIONS Prepared For Nine Mile Point Nuclear Power Station P.O. Box 63 Lycoming, New York 13093 Commercial Service Date: NRC Docket Number: Document Number: December 26, 1969 50-220 -NMP1 -ISI-OAR-003-01 Revision Number: 0o Date: July 17, 2001

Nine Mile Point Nuclear Power Station Unit I NMPI-lSI-OAR-003-01 Niagara i Mohaw. THIRD INSERVICE INSPECTION INTERVAL Rev. 0 W M %NYMohmVk 2001 OWNERWjACTIVITY REPORTDaeJuy1,20 FOR Date: July 17, 2001 INSERVICE EXAMINATIONS Pace i - 2 of i - 12 TABLE OF CONTENTS Table of Contents............................................ i-2 Record of Revision..................... i-3 Abstract.............................................................................. i-4 Form OAR-1 Owners Activity Report (2001 Refueling Outage).................................... i-7 Table 1 Abstract of Examination and Tests............................... i-8 Table 2 Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service.i-9 Table 3 Abstract of Repairs, Replacements, or Corrective Measures Required for Continued Service. i-10 File: OAR-i ISM16.WPO

Nine Mile Point Nuclear Power Station Unit I NMPI-ISI-OAR-003-01 9 THIRD INSERVICE INSPECTION INTERVAL Rev. 0 Niagara YMohaWk 2001 OWNERS' ACTIVITY REPORT FOR Date: July 17, 2001 I__________________ INSERVICE EXAMINATIONS Paoe 1-3 of 1-12 0 July 17, 2001 Entire Document Initial issue of Owner's Activity Report for ASME Section XI Inservice Examinations in accordance with the requirements of ASME Code Case N-532 in lieu of IWA-6000 as granted by USNRC Safety Evaluation, dated October 5, 2000, Request for Relief ISI-8. File: OAR-11SI16.WPD

l I i Nine Mile Point Nuclear Power Station Unit 1 NMP1-ISI-OAR-003-01 l . a f'w THIRD INSERVICE INSPECTION INTERVAL Rev. 0 {NiagMUMgMOIaWK 2001 OWNERS' ACTIVITY REPORT FOR I Date: July 17, 2001 I INSERVICE EXAMINATIONS I Paae i-4 of i-12 ABSTRACT This Owner's Activity Report summarizes the results of the Nine Mile Point Nuclear Power Station, Unit 1, ASME Section XI Inservice Examinations performed during the First Refueling Outage (RFO-16) of the First Inservice Inspection Period that started on 26 December 1999 and is scheduled to end on 25 December 2002. As an alternate to the requirements of the American Society of Mechanical Engineers (ASME), Boiler and Pressure vessel Code (B&PVC), Section Xl, Article IWA-6000, NMPC submitted Request for Relief ISI-8 on October 30, 1999, under Letter NMP1 L 1480, to implement ASME Code Case N-532, Alternative Requirements to Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000, Section Xl, Division'1 ". USNRC Safety Evaluation dated October 5, 2000, under TAC No. MA7129 authorized use of this alternative. An Owner's Activity Report Form OAR-1, was prepared and certified upon completion of the 2001 refueling outage (RFO-1 6) Examination activity. Note: Pursuant to 10 CFR 50.55a(a)(3)(i) ASME Code Case N-582 is authorized for the Third Ten-Year Inservice Inspection Interval, or until ASME Code Case N-532 is approved for general use by reference in 10 CFR 50.55a (previously Regulatory Guide 1.147). After that time, NMPC must follow the conditions, if any, specified in the regulation. In addition to the Owner's Activity Report, Form OAR-1, the following Tables are also included:

a.

Abstract of Examinations and Tests, Table 1, provides such information as ASME Code Examination Category, Total Examinations Required for the Inspection Interval, Total Examinations Required for this Period, Total Examinations Credited (%) for this Period, Total Examinations Credited (%) to Date for the Interval, and any remarks that may be applicable.

b.

Items-with Flaws or Relevant Conditions that Require Evaluation for Continued Service, Table 2, provides a listing of item(s) with flaws or relevant conditions that required evaluation to determine acceptability for continued service, whether or not the flaw or relevant condition was discovered during a scheduled examination or test, and provides such information as Examination Category, Examination Item Number, Item Description, Flaw Characterization (as required by IWA-3300), and whether the flaw or relevant condition was found during a scheduled Section Xl examination or test.

c.

Abstract of Repairs, Replacements or Corrective Measures Required for Continued Service, Table 3, identifies those items containing flaws or relevant conditions that exceeded the ASME Section Xl acceptance criteria (IWX-3000) or in the case of supports IWF-3000 acceptance criteria; even though the discovery of the flaw or relevant condition that necessitated the repair, replacement or corrective measure, may not have resulted from anexamination or test required by Section Xl, and provides such information as Code Class, whether the item is a repair, replacement or corrective action, item description, description of work, if the flaw or relevant condition was found during a scheduled Section XI Examination or test, date completed and the repair replacement plan number. File: OAR-1ISI16.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-ISI-OAR-003-01 dmh~ THIRD INSERVICE INSPECTION INTERVAL Rev. 0 N!agara MooawK 2001 OWNERS' ACTIVITY REPORT FOR Date: July 17, 2001 INSERVICE EXAMINATIONS Page I -5 of 1-12 Form OAR-1 and the applicable Tables were prepared following the completion of the First Refueling Outage (RFO-

16) which started on March 18,2001 and ended on May 18,2001. The Nine Mile Point Unit 1 (NMP1) First Inservice Inspection Period which started on December 26, 1999 and was scheduled to end on December 25, 2002 is being extended to April 23, 2003, approximately three (3) months and twenty-three (23) days, in order to complete the examination category percentages required by IWB-2412-1.

In accordance with ASME Section Xl, IWB-2412 (a), with the-exception of the examinations that may be deferred until the end of the inspection interval as specified in Table IWB-2500-1, the required examinations in each examination category shall be completed during each successive inspection interval in accordance with Table IWB-2412-1, and per IWB-2412 (b) the inspection period specified in (a) above may be decreased or extended by as much as 1 year to enable an inspection to coincide with a plant outage, within the limitations of iWA-2430(d). The following examination categories are being extended primarily due to a crud burst at the start of the refueling outage that resulted in an excessively high radiation level in the drywell. The ASME Section Xl Examination Categories being re-scheduled to refueling outage seventeen (RFO-1 7), the next scheduled refueling outage are as follows:

1.

Examination Category B-D;

2.

Examination Category B-K;

3.

Examination Category B-N-1;

4.

Examination Categories B-F, B-J, C-F-1 and C-F-2 are not being rescheduled because the USNRC authorized NMPC Request for Relief IS-13, which replaces these examinations with a Risk-informed ISI Program.

5.

Examination Category C-G states that deferral of examinations are authorized by NMPC Request for Relief ISI-7, therefore, Inspection Program EBB percentages are not required. Note: The above rescheduled items will be separated from the examinations required for the Second Inservice Examination Period, starting on December 26, 2002 in refueling outage seventeen (RFO-

17) in order to avoid dual credit.

Although specifically not addressed in the ASME Code Case, NMPC approximate submittal date will be ninety (90) days following the end of each specific inspection period. This Owner's Activity Report will be submitted as defined in the Table below following completion of RFO-17. Owner's Activity Report Submittals Inspection Periods Inspection Period End Refueling Outage Outage Approximate Dates Year Submittal Date 1 ST. period December 25, 2002 RFO-1 6 2001 Extended 1S. Period April 23, 2003 RFO-1 7 2003 July 23, 2003 Extension File: OAR-11S116.WPO

Nine Mile Point Nuclear Power Station Unit 1 NMPI-lSI-OAR-003-01 N.agara 2 N THIRD INSERVICE INSPECTION INTERVAL Rev. 0 rlgaa %i~M oh a wk 2001 OWNERS ACTIVITY REPORT FOR Date: July 17, 2001 INSERVICE EXAMINATIONS Parle i -S6 of i-12 FORM OAR-1 OWNER'S ACTIVITY REPORT As required by the provisions of the ASME Code Case N-532 Report Number NMP1 -ISI-OAR-003-01 Owner PInt Niagara Mohawk Power Corporation. 300 Erie Boulevard West. Syracuse. New York 13252 (Name and Address of Owner) Nine Mile Point Nuclear Power Station. P. 0. Box 63. Lvcomina. New York 13093 . *c^ &v (Name and Address of Plant) Plant Unit 1 Commercial Service Date December 26. 1969 Refueling Outage Number RFO-16 Current Inspection Interval Third Inservice Insoection Interval - December 26. 1999 to December 25. 2009 (1st, 2nd, 3rd, 4th, Other) Current Inspection Period First Inservice Inspection Period - December 26. 1999 to December 25. 2002 (1st, 2nd, 3rd) Edition and Addenda of Section XI applicable to the Inspection Plan 1989 Edition. No Addenda Date and Revision of Inspection Plan NMP1-PT-003. Revision 1. Dated March 1. 2001 Edition and Addenda of ASME Section Xl applicable to Repairs and Replacements, if different than the Inspection Plan N/A CERTIFICATE OF CONFORMANCE I certify that the statements made in this Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations and corrective measures represented by this report conform to the requirements of Section Xl. Certificate of Authorization No. N/A Expiration Date-NIA 2995t ' /~~~)A ->pplicae) Signed t / Date_____ (Supervisor - ASME Section Xl Proarams Group) CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York and employed by Factory Mutual Insurance Companv of Johnston. Rhode Island have inspected the items described.in this Owners Activity Report, during the period March 18. 2001 to May 18. 2001 and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations and corrective measures described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. g o = G Commissions NB 8496 C7 Inspectors Signature National Board, State, Province, and Endorsements Date 7 /L 6 2ov'I File: OAR-i 11 6.WPD

Nine Mile Point Nuclear Power Station Unit I NMPI-ISI-OAR-003-01 ffi THIRD INSERVICE INSPECTION INTERVAL Rev. 0 Niagara1MoIhawK 2001 OWNERS' ACTIVITY REPORT I >zx FOR Date: July 17, 2001 ____________________l INSERVICE EXAMINATIONS Paae i -7 of i -12 FORM OAR-1 OWNER'S ACTIVITY REPORT As required by the provisions of the ASME Code Case N-532 Report Number NMP1 -ISI-OAR-003-01 Owner PIant Niagara Mohawk Power Corgoration. 300 Erie Boulevard West. Syracuse. New York 13252 (Name and Address of Owner) Nine Mile Point Nuclear Power Station. P. 0. Box 63. Lycomina. New York 13093 (Name and Address of Plant) Plant Unit 1 Commercial Service Date December 26. 1969 Refueling Outage Number RFO-16 Current Inspection Interval Third Inservice Inspection Interval - December 26. 1999 to December 25. 2009 (1st, 2nd, 3rd, 4th, Other) Current Inspection Period First Inservice Inspection Period -December 26. 1999 to December 25. 2002 (1st, 2nd, 3rd) Edition and Addenda of Section Xi applicable to the Inspection Plan 1989 Edition. No Addenda Date and Revision of Inspection Plan NMP1-ISI-003-10. Revision 1. Dated March 13. 2001 Edition and Addenda of ASME Section Xl applicable to Repairs-and Replacements, if different than the Inspection Plan N/A CERTIFICATE OF CONFORMANCE I certify that the statements made in this Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements. evaluations and corrective measures represented by this report conform to the requirements of Section Xl. Certificate of Authorization No. NIA Expiration Date N/A l SM io blP a Signed -j# 4 {Date 7,54 (Supervisor - ASME Section XI Programs Group)I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York and employed by Factory Mutual Insurance Company of Johnston. Rhode Island have inspected the items described in this Owners Activity Report, during the period March 18. 2001 to May 18. 2001 and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations and corrective measures described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ,to Commissions NB 8496 / Inspector's Signature National Board, State, Province, and Endorsements Date 7 l;L 20 fEL File: OAR-i15116.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMPI-ISI-OAR-003-01 THIRD INSERVICE INSPECTION INTERVAL Rev. o Nli~a~ratN, Mohawk 2001 OWNERS 'ACTIVITY REPORT FOR Date: July 17, 2001 INSERVICE EXAMINATIONS Paae i -8 of i -12 TABLE 1 ABSTRACT OF EXAMINATION AND TESTS As required by the provisions of the ASME Code Case N-532 TOTAL TOTAL 'TOTAL TOTAL EXAMNATIONS CODE EXAMINATIONS EXAMINATIONS EXAMINATIONS CREDITED (%) TO EXAMINATION REQUIRED FOR REQUIRED FOR CREDITED (%) DATE FOR THE REMARKS CATEGORY INTERVAL THIS PERIOD FOR THE PERIOD INTERVAL REMARKS B-A 42 a 8 -100% 19.0% Deferral Permissible, Insp. Prog B' Compliance B-D s0 23 11 - 47.8% 13.7% Deferral Permissible, Category E x t e n d e d B-E 2 0 0-0% 0% Deferral Permissible B-F 38 12 0-0°b 0% Deferred Per RR-ISI-13 B-G-1 403 143 143 -100% 35.4% Insp. Prog. B' Compliance B-G-2 77 35 26 - 74.2% 33.7% Insp. Prog. 'B' Compliance B-J 148 48 0-0% 0% Deferred Per RR-ISI-13 B-K 28 6 0-0% 0% Category Extended B-L-2 1 0 0-0% 0% Deferral Permissible B-M-1 1 0 0-0% 0% Deferral Permissible B-M-2 18 8 4-50% 22.2% Deferral Permissible, Insp. .P rog. B ' C om pliance B-N-1 24 8 5 -62.5% 20.8% Category Extended B-N-2 35 .5 5 - 100% 14.2% Deferral Permissible 8-0 8 2 0-0% 0% Deferral Permissible B-P N/A N/A 97 - N/A NIA Excluded from Insp. Prog. *B' C-A 4 1 1 -100% 25% lnsp. Prog. B' Compliance C-A 4 1 1 -100% 25% Insp. Prog. *'E Compliance C-C 93 26 26 -100% 27.9% Insp. Prog. *' Compliance C-F-1 28 10 0-0% 0% Deferred Per RR-ISI-1 3 C-F-2 50 18 0-0% 0% Deferred Per RR-ISI-13 C-G 19 11 1 - 1% 0% Deferred Per RR-ISI-7 C-H-NIA N/A 3 - N/A NIA Excluded from Insp. Prog. IB-D-A 56 18 18-100% 32.1% Insp. Prog. B' Compliance F-A 1 R4 1 48. Fick Insp. Proq. 'B' Compliance File: OAR-1 ISI1 6.WPD

Nine Mile Point Nuclear Power Station Unit I NMPI-ISI-OAR-003-01 N.agara THIRD INSERVICE INSPECTION INTERVAL Rev. 0 Mlamra MohaWk 2001 OWNERS' ACTIVITY REPORT 2001 OWNERS' FOR Date: July 17, 2001 ____________________j INSERVICE EXAMINATIONS Pane I -9 of 1-12 TABLE 2 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRE EVALUATION FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT FLAW CONDITION EXAMINATION ITEM ITEM CHARACTERI7ATION FOUND DURING CATEGORY NUMBER DESCRIPTION (MWA-3300) SCHEDULED SECTION Xi EXAMUNATION OR TEST (YES OR NO) TS TS.01 01-HS-07 Hydraulic Snubber Leaking Reservoir No F-A F1.20 39-H22 Variable Spring Pipe Support Loose Pipe Clamp Boit Yes B-J 89.11 32-WD-046 Safe-End to Elbow Surface Planar Indication Yes (1) B-J B9.11 32-WD-050 Valve-to-Pipe Surface Planar Indication Yes (1) B-J B9.11 32-WD-086 Safe-End to Elbow Surface Planar Indication Yes (1) B-J B9.11 32-WD-1 26 Safe-End to Elbow Surface Planar Indications Yes (1) B-J B9.11 32-WD-168 Safe-End to Elbow Surface Planar Indications Yes (1) 8-P B15.10 CRD-N1-B (CRD 26-47) Bolted Flange Connection Leak Yes B-P B15.10 CRD-US-B (CRD 18-03) Bolted Flange Connection Leak Yes B-P 815.10 CRD-U8-B (CRD 18-51) Bolted Flange Connection Leak Yes B-P 615.10 CRD-N9-B (C R Di 0-1 5) Bolted Flange Connection Leak Yes B-P B15.10 CRD-E3-B (CRD 18-19) Bolted Flange Connection Leak Yes B-P B15.10 CRD-L-1B (CRD 38-39) Bolted Flange Connection Leak Yes B-P B15.10 CRD-N4-B (CRD 48-27) Bolted Flange Connection Leak Yes B-P B15.70 32-213 Boled Flange Connection Leak Yes B-P 815.70 HCU 14-07 Valve 126 Bolted Flange Connection Leak Yes B-N-2 813.30 Shroud Supp rt Weld H9 Circumferential Cracking No (2) B-N-2 813.40 Core Spray Sparger Nozzle 2A Cracking No (2) B-N-2 B13.40 Steam Dryer Cracking No (2) Note: (1) All B-J B9.11 welds identirieg atove ar Iso classified as IGCC Category F welds, and have been previously reported and accepte per Analytical tva uatbon.ltTnese are re-examina ions. (2) All B-N-2 items identified above were identified under the BWRVIP (IWI) Augmented Examination. File: OAR-i 1II1 6.WPD

Nine Mile Point Nuclear Power Station Unit I NMPI-ISI-OAR-003-01 AM THIRD INSERVICE INSPECTION INTERVAL Rev. 0 Nbaugfa ~Mohawk I 2001 OWNERS' ACTIVITY REPORT Iiagara~ohawk FOR Date: July 17, 2001 ____________________j INSERVICE EXAMINATIONS Paae i-10 of i-12 TABLE 3 ABSTRACT OF REPAIRS, REPLACEMENTS, OR CORRECTIVE MEASURES REQUIRED FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT REPAIR CONDITION FOUND REPLACEMENT DURING SCHEDULED REPAIR OR DESCRIPTION SECTION Xl REPLACEMENT CODE CORRECTIVE ITEM OF EXAMINATION OR TEST DATE PLAN CLASS MEASURE DESCRIPTION WORK (YES OR NO) COMPLETE NUMBER 1 Replacement DRV-44.1015 Replaced CRD and YES 06/27/01 WO 98-06012-00 CRD-N9-B (8) Cap Screws 1 Replacement CKV40-03 Replaced center NO 06129101 WO 98-07495-00 I_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ se c tio n o f v alv e 1 Replacement DRV-44-3835 Replaced CRD and NO 06127101 WO 99-03060-00 CRD-H2-B (8) Cap Screws 1 Replacement DRV44-2647 Replaced CRO and YES 06t27101 WO 99-04722-00 I___________ CRD-N1-B (8) Cap Screws 1 Replacement DRV441-1039 Replaced CRD and NO 06/27101 WO 99-05299-00 CRD-N11-8 (8) Cap Screws 1 Replacement CKV-31-1 R Replaced (18) NO 06/29/01 WO 99-06248-00 washers and (2) studs 1 Replacement ORV44-3019 Replaced (8) Cap NO 06W27101 WO 99-07806-00 _____CRD-D4-8 Screws I Replacement / IV-33-02R Installed new valve, NO 07103/01 WO 99-08279-01 Repair 33-WD-004BR1 Replaced studs and 33-WD-04DR1 nuts, Repaired manufacturing lap/seam and installed new welds ASME CC N-416-1 1 Re pacement 33-H3 Installed larger hanger NO 07103/01 WO 99-08279-22 1 Replacement DRV-44-4615 Replaced CRD and NO 06/27t01 WO 99-08292-00 CRD-R3-B (8) Cap Screws 1 Replacement PSV-01-119A Replaced (9) Safety NO 06/29/01 W000-02429-00 PSV-01-119B Relief Valves PSV-01-119C PSV-01-1190 PSV-01-119F PSV-01-119G PSV-01-119H PSV401-119J PSV-01-119M 1 Replacement CKV-39-04 Replaced (2) studs NO 06/29/01 WO 00-02695-04 and nuts and lapped valve 2 Replacement 39-HS-28 Replaced pipe clamp NO 06/29101 WO 00-02065-05 I _ _ _ _ _ _ b o lts a n d n u ts 1 Replacement DRV-44-1023 Replaced CRD and NO 06/27/01 WO 00-05597-02 CRD-K0-8 (8) Cap Screws 1 Replacement ORV44-3007 Replaced CRD and NO 06/27/01 WO 00-08349-00 CRD-04-8 (8) Cap Screws 1 Replacement ORV44-1843 Replaced CRD and NO 06/27101 WO 00-08355-00 CRD-M8-B (8) Cap Screws File: OAR-1 ISI1 6.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMPI-ISI-OAR-003-01 THIRD INSERVICE INSPECTION INTERVAL Rev. 0 Niagara Mohawk 2001 OWNERS' ACTIVITY REPORT FOR Date: July 17, 2001 INSERVICE EXAMINATIONS Paae i -11 of i -12 FLAW OR RELEVANT REPAIR CONDITION FOUND REPLACEMENT DURING SCHEDULED REPAIR OR DESCRIPTION SECTION Xi REPLACEMENT CODE CORRECTIVE ITEM OF EXAMINATION OR TEST DATE PLAN CLASS MEASURE DESCRIPTION WORK (YES OR NO) COMPLETE NUMBER 1 Replacement DRV-44-1803 Re placed CRD and YES 06/27/01 WO 00.08356-00 CRD-U5-B (8) Cap Screws 1 Replacement DRV-44-3839 Re laced CRD and YES 06/27/01 WO 00-08357-00 CRD-Li-B (8) Cap Screws 1 Replacement DRV-44-1819 Re placed CR0 and YES 06/27101 WO 0008358-00 CRO-E3-B (8) Cap Screws 1 Replacement CKV-31-02R Replaced (8) nuts and NO 06129/01 WO 01-01830-00 (I8) washers and (11) studs 1 Replacement CKV-31-02R Installed Helicoil in No 06/29/01 WO 01.01830-02 stud holes 10, 11, 13 ~~~an d _1 7 File: OAR-1 ISI1 6.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-ISI-OAR-003-01 N.agA 2 THIRD INSERVICE INSPECTION INTERVAL Rev. 0 N NNoabW2001 OWNERS' ACTIVITY REPORTl FOR Date: July 17, 2001 - INSERVICE EXAMINATIONS Paae i-12 of i-12 End of Inservice Inspection Owner's Activity Report For Refueling Outage Sixteen (RFO-16) File: OAR-I1SI16.WPD

Constellation Energy Group Nine Mile Point Nuclear Station Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lake Road Lycoming, New York 13093 ENCLOSURE 2 THIRD INSERVICE INSPECTION INTERVAL FIRST INSERVICE INSPECTION PERIOD 2003 OWNER'S ACTIVITY REPORT FOR INSERVICE EXAMINATIONS Prepared For Nine Mile Point Nuclear Station P.O. Box 63 Lycoming, New York 13093 Commercial Service Date: NRC Docket Number: Document Number: December 26, 1969 50-220 NMP1 -ISI-OAR-003-01 -A Revision Number: 00 Date:April 23, 2003

Nine Mile Point Nuclear Station Unit I NMP1-ISI-OAR-003-01-A Constellabion THIRD INSERVICE INSPECTION INTERVAL Rev. 00 CoEnergy Group 2003 OWNERS' ACTIVITY REPORT Nine MePoeitl FOR Date: April 23, 2003 Nudear Station INSERVICE EXAMINATIONS =Page 1-2 of 1-10 TABLE OF CONTENTS Table of Contents............ i-2 Record of Revision............... 1.... i-3 Abstract............... i-4 Form OAR-1 Owner's Activity Report for Inspection Plan NMP1 -ISI-003 (2003 Refueling Outage)... i-6 Table 1 Abstract of Examination and Tests................................................. 1-7 Table 2 Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service...... i-8 Table 3 Abstract of Repairs, Replacements, or Corrective Measures Required for Continued Service.. i-9 File: OARi-11SI1681.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-01-A Constellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 Energy Group 2003 OWNERS' ACTIVITY REPORT Nmne Mile Point FOR Date: April 23, 2003 Nuclear Station INSERVICE EXAMINATIONS I Page 1-3 of 1-10 File: OAR-11lS16R1.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-01-A ~onstelllafioh ~ THIRD INSERVICE INSPECTION INTERVAL Rev. 00 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine IMle Point FOR Date: April 23, 2003 Nuclear Station INSERVICE EXAMINATIONS Page i-4 of 1-10 ABSTRACT This Owner's Activity Report summarizes the results of the Nine Mile Point Nuclear Station (NMPNS), Unit 1, ASME Section Xl Inservice Examinations that were re-scheduled to refueling outage seventeen (RFO-17) as a result of a crud burst that resulted in excessively high radiation levels in the drywell. The First Inservice Inspection Period started on 26 December 1999 and was originally scheduled to end on 25 December 2002. Due to the crud burst, the First Inspection Period was extended to April 23, 2003. As an alternate to the requirements of the American Society of Mechanical Engineers (ASME), Boiler and Pressure vessel Code (B&PVC), Section Xl, Article IWA-6000, NMPNS submitted Request for Relief ISI-8 on October 30, 1999, under Letter NMP1 L 1480, to implement ASME Code Case N-532, "Alternative Requirements to Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000, Section Xl, Division 1". USNRC Safety Evaluation dated October 5, 2000, under TAC No. MA7129 authorized use of this alternative. An Owner's Activity Report Form OAR-1, was prepared and certified upon completion of the 2001 refueling outage (RFO-16) Examination activity. The OAR is being supplemented to indude the results of the re-scheduled inservice examinations in order to close-out the first inservice inspection period percentage requirements. Note: Pursuant to 1 0 CFR 50.55a(a)(3)(i) ASME Code Case N-532 is authorized for the Third Ten-Year Inservice Inspection Interval, or until ASME Code Case N-532 is approved for general use by reference in 10 CFR 50.55a (previously Regulatory Guide 1.147). After that time, NMPNS must follow the conditions, if any, specified in the regulation. In addition to the Owner's Activity Report, Form OAR-1, the following Tables are also included:

a.

Abstract of Examinations and Tests, Table 1, provides such information as ASME Code Examination Category, Total Examinations Required for the Inspection Interval, Total Examinations Required for this Period, Total Examinations Credited (%) for this Period, Total Examinations Credited (%) to Date for the Interval, and any remarks that may be applicable.

b.

Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service, Table 2, provides a listing of item(s) with flaws or relevant conditions that required evaluation to determine acceptability for continued service, whether or not the flaw or relevant condition was discovered during a scheduled examination or test, and provides such information as Examination Category, Examination Item Number, Item Description, Flaw Characterization (as required by IWA-3300), and whether the flaw or relevant condition was found during a scheduled Section Xl examination or test.

c.

Abstract of Repairs, Replacements or Corrective Measures Required for Continued Service, Table 3, identifies those items containing flaws or relevant conditions that exceeded the ASME Section Xi acceptance criteria (IWX-3000) or in the case of supports IWF-3000 acceptance criteria; even though the discovery of the flaw or relevant condition that necessitated the repair, replacement or corrective measure, may not have resulted from an examination or test required by Section Xl, and provides such information as Code Class, whether the item is a repair, replacement or corrective action, item description, description of work, if the flaw or relevant condition was found during a File: OAR-1lSI16R1.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-01-A s~ Constellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Wle Point FOR Date: April 23, 2003 Nuclear Station INSERVICE EXAMINATIONS I _____________ Page i-5 of 1-10 scheduled Section Xl Examination or test, date completed and the repair replacement plan number. Form OAR-1 and applicable Tables were prepared following the completion of the rescheduled examinations performed during Refueling Outage (RFO-17), which started on March 14, 2003 and ended on April 23,2003. With the completion of this OAR-1 and the associated Tables, the First Inservice Inspection Period for Nine Mile Point Nuclear Station, Unit 1 is closed-out. In accordance with ASME Section Xl, IWB-2412 (a), with the exception of the examinations that may be deferred until the end of the inspection interval as specified in Table IWB-2500-1, the required examinations in each examination category shall be completed during each successive inspection interval in accordance with Table IWB-2412-1, and per IWB-2412 (b) the inspection period specified in (a) above may be decreased or extended by as much as 1 year to enable an inspection to coincide with a plant outage, within the limitations of IWA-2430(d). Although specifically not addressed in the ASME Code Case, NMPNS approximate submittal date will be ninety (90) days following the end of each specific inspection period. File: OAR-11S116R1.WPO

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-01-A O Constellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 0 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine 1We Point FOR Date: April 23, 2003 Nuclear Station INSERVICE EXAMINATIONS Page 1-6 of 1-10 FORM OAR-1 OWNER'S ACTIVITY REPORT As required by the provisions of the ASME Code Case N-532 Report Number NMP1 -I.RI-flAR-no.;-fl1 -A Owner Nine Mile Point Nuclear Station. LLC. P.O. Box 63. Lake Road. Lycomina. New York 13093 (Name and Address of Owner) Plant Nine Mile Point Nuclear Station. P. 0. Box 63. Lycomino. New York 13093 (Name and Address of Plant) Plant Unit 1 Commercial Service Date December 26.1969 Refueling Outage Number RFO-17 Current Inspection Interval Third Inservice Inspection Interval - December 26. 1999 to December 25. 2009 (1 st, 2nd, 3rd, 4th, Other) Current Inspection Period First Inservice Inspection Period - December 26.1999 to December 25. 2002 (1st, 2nd, 3rd) Edition and Addenda of Section Xl applicable to the Inspection Plan 1989 Edition. No Addenda Date and Revision of Inspection Plan NMP1-ISI-003. Revision 2. Dated September 25. 2002 Edition and Addenda of ASME Section Xl applicable to Repairs and Replacements. If different than the Inspection Plan N/A CERTIFICATE OF CONFORMANCE I certify that the statements made in this Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations and corrective measures represented by this report conform to the requirements of Section Xl. Certificate of Authorization No. N/A 9'ze' A? A9Q(f applicable) Expiration Date N/A Date >/2L 32-i Signed (Principal Engineer -ASME Section Xl Programs Group) CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York and employed by Factory Mutual Insurance Companv of Johnston. Rhode Island have inspected the items described in this Owner's Activity Report, during the period March 14. 2003 to Anri 23. 2003 and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations and corrective measures described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. i , £0 C Commissions NB 8496 L7 Inspectors Signature National Board, State, Province, and Endorsements Date 4 [;Z. 20°3 File: OAR-11SI16Rl.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-01-A 9% Constellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 CEnergY Group 2003 OWNERS' ACTIVITY REPORT Nine Mle Point FOR Date: April 23, 2003 Nuclear Station INSERVICE EXAMINATIONS I Page i-7 of t-10 TABLE 1 ABSTRACT OF EXAMINATION AND TESTS As required by the provisions of the ASME Code Case N-532 TOTAL TOTAL 'TOTAL TOTAL EXAMINATIONS CODE EXAMINATIONS EXAMINATIONS EXAMINATIONS CREDITED (%) TO EXAMINATION REQUIRED FOR REQUIRED FOR CREDITED (%) DATE FOR THE CATEGORY INTERVAL THIS PERIOD FOR THE PERIOD INTERVAL REMARKS B-A 42 8 8-100% 19.0% Deferral Permissible B-D 80 23 21 -91% 26% Deferral Permissible B-E 2 0 0 -0% 0% Deferral Permissible B-F 38 12 2.17% 5% Percentages not required Per NRC a p p ro v e d R R -IS I-1 3 B-G-1 403 143 143-100% 35% Insp. Prog. B' Compliance B-G-2 77 35 26 - 74% 34% Insp. Prog. EB Compliance B-J 148 48 0 - 0% 0% Percentages not required Per NRC ap pro v ed R R -IS I-13 B-K 11 2 2-100% 18% Insp. Prog. 6B' Compliance B-L-2 1 0 0 -0% 0% Deferral Permissible B-M-1 1 0 0-0% 0% Deferral Permissible B-M-2 18 8 4 -50% 22% Deferral Permissible B-N-1 30 10 9-90% 30% Insp. Prog. 'F Compliance B-N-2 28 5 5 - 100/ 18% Deferral Permissible B-0 8 2 0 - 0% 0% Deferral Permissible C-A 4 1 1 - 100% 25% Insp. Prog. B Compliance C-B 4 1 1 -100% 25% Insp. Prog. B' Compliance C-C 32 10 10 100% 31% lnsp. Prog. 'B Compliance C-F-1 28 10 0 - 0% 0% Percentages not required Per NRC I_____________ approved R R-IS I-1 3 C-F-2 50 18 0 - 0% 0% Percentages not required Per NRC I____________ approved R R -ISI-13 C.G 19 11 6 - 55% 32% Deferral Permissible Per NRC a p p ro v e d R R -IS I-7 L D-A 25 8 8 -100% 32% Insp. Prog. 'B' Compliance l___F-A_____ iR4 R1 AI -7A RW% 27N4 Insp. Prog. TB" Compliance File: OAR-11SI16RI.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-01-A Constellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Iile Pint FOR Date: April 23, 2003 Nuclear Station INSERVICE EXAMINATIONS .Page 1-8 of 1-10 TABLE 2 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRE EVALUATION FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT FLAW CONDITION EXAMINATION ITEM ITEM CHARACTERIZATION FOUND DURING CATEGORY NUMBER DESCRIPTION (IWA-3300) SCHEDULED SECTION XI EXAMINATION OR TEST (YES OR NO) B-N-1 B13.10 RV-03-I-CH RP Closure Head Interior (12) Linear indications Yes urrace,~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ I _ 4 I__ I File: OAR-iIS116R1.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-01-A THIRD INSERVICE INSPECTION INTERVAL Rev. 00 , -EConstellarGon 2003 OWNERS' ACTIVITY REPORT Mne Mile Point FOR Date: April 23, 2003 NudearSlaton INSERVICE EXAMINATIONS _Page 1-9 of 1-10 TABLE 3 ABSTRACT OF REPAIRS, REPLACEMENTS OR CORRECTIVE MEASURES REQUIRED FOR CONTINULED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT REPAIR CONDITION FOUND REPLACEMENT DURING SCHEDULED REPAIR OR DESCRIPTION SECTION Xi REPLACEMENT CODE CORRECTIVE ITEM OF EXAMINATION OR TEST DATE PLAN CLASS MEASURE DESCRIPTION WORK (YES OR NO) COMPLETE NUMBER No Repairs /Replacements required for the extended period e:aminations File: OAR-1 ISI16R1.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-01-A CosenonTHIRD INSERVICE INSPECTION INTERVAL Rev. 00 _ Energy Group 2003 OWNERS' ACTIVITY REPORT I Nine Wie Pon FOR Date: April 23, 2003 l NuclearStmation INSERVICE EXAMINATIONS Page 1-10 of 1-10 End of Inservice Inspection Owner's Activity Report For Refueling Outage Seventeen (RFO-17) File: OAR-1iSI16R1.WPD

Niagara I QMohawk Niagara Mohawk Power Corporation 300 Erie Boulevard West Syracuse, New York 13252 ENCLOSURE 3 FIRST INSERVICE INSPECTION INTERVAL FIRST INSERVICE INSPECTION PERIOD 1999 CONTAINMENT INSERVICE INSPECTION OWNER'S ACTIVITY REPORT Prepared For Nine Mile Point Nuclear Power Station P.O. Box 63 Lycoming, New York 13093 Commercial Service Date: NRC Docket Number: Document Number: December 26, 1969 50-220 NMP1 -IWE-OAR-003-01 Revision Number 0o Date: July 17, 2001

Nine Mile Point Nuclear Power Station Unit I NMPI-IWE-OAR-003-01 o 19CT FIRST INSERVICE INSPECTION INTERVAL Rev. 0 Niaparahlu ohawk 1999 CON TAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 _________________j REPORT Paae i-2 of i-11 TABLE OF CONTENTS Table of Contents............. i-2 Record of Revision................................................- i-3 Abstract. i-4 Form OAR-1 Owner's Activity Report (1999 Refueling Outage).i-6 Table 1 Abstract of Examination and Tests............................................... i-7 Table 2 Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service. i-8 Table 3 Abstract of Repairs, Replacements, or Corrective Measures Required for Continued Service. i-9 Table 4 Owners' Data report for Inaccessible Areas.1-10 File: OAR-1VWE I S.WPD

Nine Mile Point Nuclear Power Station Unit I NMP1-4WE-OAR-003-01 .iAga~MhakI FIRST INSERVICE INSPECTION INTERVAL Rev. 0 M292M .6gMohawk 1999 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 REPORT Paci i1-3 of i-11 0 July 17, 2001 Entire Document Initial issue of Owners Activity Report in accordance with the requirements of ASME Code Case N-532 in lieu of IWA-6000 as granted by USNRC Safety

  • Evaluation, dated October 5, 2000, Request for Relief ISI-8.

File: OAR-1 IWE1 5.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMPI-IWE-OAR-003-01 Niagara Mohawk FIRST INSERVICE INSPECTION INTERVAL Rev. 0 Nilara Ag3>~Mohawk 1999 CONTAINMENT INSPECTION 0 - QRN OWNER'S ACTIVITY Date: July 17, 2001 l REPORT Paae i-4 of i-11 ABSTRACT This Owner's Activity Report summarizes the results of the Nine Mile Point Nuclear Power Station, Unit 1, First Containment Inservice Inspection Period that started on 26 December 1999 and ends on 25 December 2002. The first inservice inspection period consists of refueling outages fifteen (RFO-15) and sixteen (RFO-1 6). As a alternate to the requirements of the American Society of Mechanical Engineers (ASME), Boiler and Pressure vessel Code (B&PVC), Section Xl, Article IWA-6000, NMPC submitted Request for Relief ISI-8 on October 30, 1999, under Letter NMP1 L 1480, to implement ASME Code Case N-532, 'Alternative Requirements to Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000, Section XI, Division 1". USNRC Safety Evaluation dated October 5, 2000, under TAC No. MA7129 authorized use of this alternative. IWE Containment Inservice examinations were initially performed during refueling outage (RFO-1 5), which were conducted during the period of April 6,1999 through June 16, 1999. The IWE examinations consisted of examining the general condition of the Torus internal pressure retaining components at or below the waterline. The results of these inspections were documented in the RFO-15 Torus Inspection Plan, Document NER-1 S-025, Revision 1, and was provided in Appendix D of the 1999 Summary Report Submittal. In order to meet the intent of ASME Code Case N-532, an Owners' Activity Report Form OAR-1 was prepared to document the 1999 (RFO-15) Examination activity. Note: Pursuant to 10 CFR 50.55a(a)(3)(i) ASME Code Case N-532 is authorized for the Third Ten-Year Inservice Inspection Interval, or until ASME Code Case N-532 is approved for general use by reference in 10 CFR 50.55a (previously Regulatory Guide 1.147). After that time, NMPC must follow the conditions, if any, specified in the regulation. In addition to the Owner's Activity Report, Form OAR-1, the following Tables are also included:

a.

Abstract of Examinations and Tests, Table 1, that provides such information as ASME Code Examination Category, Total Examinations Required for the Inspection Interval, Total Examinations Required for this Period, Total Examinations Credited (%) for this Period, Total Examinations Credited (%) to Date for the Interval, and any remarks that may be applicable.

b.

Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service, Table 2, that provides a listing of item(s) with flaws or relevant conditions that required evaluation to determine acceptability for continued service, whether or not the flaw or relevant condition was discovered during a scheduled examination or test, and provides such information as Examination Category, Examination Item Number, Item Description, Flaw Characterization (as required by IWA-3300). and Whether the flaw or relevant condition was found during an scheduled Section Xi examination or test.

c.

Abstract of Repairs, Replacements or Corrective Measures Required for Continued Service, Table 3, which identify those items containing flaws or relevant conditions that exceeded the NMPC defined orASME Section Xl acceptance criteria (IWE-3000) or in the case of supports IWF-3000 acceptance criteria; even though the discovery of the flaw or relevant condition that necessitated the repair, replacement or corrective measure, may not have resulted from an examination or test required by Section Xl, and provides such information as Code Class, Whether the item is a repair, replacement or corrective action, item description, description of work, if the flaw or relevant condition was found during a scheduled Section Xl Examination or test, date completed and the repair replacement plan number. File: OAR-1lWEl5.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-01 A. FIRST INSERVICE INSPECTION INTERVAL Rev. 0 NMagaratpMMohaW 1999 CONTAINMENT INSPECTION 91agm1UV OWNER'S ACTIVITY Date: July 17,2001 I REPORT Page 1-5 of i-11 completed and the repair replacement plan number.

d.

Owners' Report for Inaccessible Areas, Table 4, as required by Code of Federal regulations 10 CFR 50.55a(b)(x), and provides such information as a description of the type and estimated extent of degradation, and condition that led to the degradation, description and results of the evaluations, and a description of the corrective actions. Note: If acceptance criteria for a particular item is not specified in Section Xi, the provisions of IWA-3100(b) may be used to determine which repairs, replacements, and corrective measures are required to be included in the abstract. The Form OAR-1 and the applicable Tables were prepared for the NMP1 First Inservice Inspection Period and is being submitted following the end of the first inspection period as defined below. Although specifically not addressed in the ASME Code Case, NMPC approximate submittal date will be ninety (90) days following the end of the each specific inspection period. Owner's Activity 'ReportSubm tis-Inspection Periods - Inspection Period End Ref ueling O.utage Outage A t Dates Y~~~ ~ ~~~~~~~ear Submittal Date 1 ST. period December 25, 2002 RFO-1 5 1999 RFO-16 2001 Extended 1 ST. Period Apri 2 203 RFO-17 2003 July 23, 2003 Extension File: OAR-1 IWE1 S.WPD

Nine Mile Point Nuclear Power Station Unit I NMPI-IWE-OAR-003-01 . = FIRST INSERVICE INSPECTION INTERVAL Rev. 0 Niagarat Mohawk 1999 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date. July 17, 2001 I REPORT Paae i -C of iI FORM OAR-1 OWNER'S ACTIVITY REPORT As required by the provisions of the ASME Code Case N-532 Report Number NMP1 -IWE-OAR-003-01 Owner Niagara Mohawk Power Corporation, 300 Erie Boulevard West. Syracuse. New York 13252 (Name and Address of Owner) Plant Nine Mile Point Nuclear Power Station, P. 0. Box 63. Lycoming. New York 13093 (Name and Address of Plant) Plant Unit 1 Co Current Inspection IntervaL mmercial Service Date December 26. 1969 Refueling Outage Number RFO-15 Pirct Inqarvinom lncnar-tinn Intan/nI fl~i-~mh~r 98 11QQQ eto nlpamhar 911 2nnol (1st, 2nd, 3rd, 4th, Other) Current Inspection Period First lnqervice insnection Period Derember 26. 1 999 to December 25 2002 (1st. 2nd, 3rd) Edition and Addenda of Section Xl applicable to the Inspection Plan 1992 Edition, 1992 Addenda Date and Revision of Inspection Plan NER-IS-025. Revision 1. Dated May 17. 1999 Edition and Addenda of ASME Section Xl applicable to Repairs and Replacements, if different than the Inspection Plan NIA CERTIFICATE OF CONFORMANCE I certify that the statements made in this Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations and corrective measures represented by this report conform to the requirements of Section Xl. Certificate of Authorization No. NIA "4xeo" If _P7-',ca Expiration Date NIA Date 7/FA Z/ Signed (Supervisor - ASME Section Xl Programs Group) CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York and employed by Factory Mutual Insurance Company of Johnston. Rhode Island have inspected the items described in this Owner's Activity Report, during the period April 6.1999 to June 16 1999 and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations and corrective measures described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. 4 9 omCo r issions NB 8496 Inspector's Signature National Board, State, Province, and Endorsements Date 720. / 6'f File: OAR-1i WE1 5.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMPI-IWE-OAR-003-01 FIRST INSERVICE INSPECTION INTERVAL Rev. 0 NiagaralmMohawk 1999 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 J~~ REPORT Page 1-7 of i-11 TABLE 1 ABSTRACT OF EXAMINATION AND TESTS As required by the provisions of the ASME Code Case N-532 TOTAL TOTAL TOTAL TOTAL EXAMINATIONS CODE EXAMINATIONS EXAMINATIONS EXAMINATIONS CREDITED (%) TO EXAMINATION REQUIRED FOR REQUIRED FOR THIS CREDITED (%) FOR THE DATE FOR THE CATEGORY INTERVAL PERIOD PERIOD INTERVAL REMARKS E-A 2322 897 19.1% 7.4% E-C 0 0 0% 0% F-A 10 2 0% 0% ASME CODE CASE N-491-1 File: OAR-1)WE15.WPD

Nine Mile Point Nuclear Power Station Unit I NMP1 -IWE-OAR-003-01 Ids 9 FIRST INSERVICE INSPECTION INTERVAL Rev. 0 N-agara\\M OawK 1999 CONTAINMENT INSPECTION L}___________________I ,OWNER'S ACTIVITY Date: July 17, 2001 REPORT Page i - 8 of I TABLE 2 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRE EVALUATION FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT FLAW CONDITION EXAMINATION ITEM ITEM CHARACTERIZATION FOUND DURING CATEGORY NUMBER DESCRIPTION (IWA-3300) SCHEDULED SECTION XI EXAMINATION OR TEST (YES OR NO) E-A E1.1 1 Torus Access Manway PENET-XS-311 Bent Lifting Lug No E-A E1.1 I PENET-XS-310 Seal Surface Gouges No E-A E1.1 1 PENET-XS-311 Seal Surface Gouges No E-A E1.11 PENET-XS-312 Seal Surface Gouges No. E-A E1.11 Dome Bolting Galling, groove, gouges No File: OAR-1 WE 1 5.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMPI-IWE-OAR-003-01 Moa. FIRST INSERVICE INSPECTION INTERVAL Rev. 0 Niagara Mohawk 199 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 l-REPORT Paae i - 9 of i-11I TABLE 3 ABSTRACT OF REPAIRS, REPLACEMENTS, OR CORRECTIVE MEASURES REQUIRED FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT CONDITION FOUND REPAIR DURING SCHEDULED REPAIR REPLACEMENT DESCRIPTION SECTION XI REPLACEMENT CODE OR CORRECTIVE ITEM OF EXAMINATION OR TEST DATE PLAN CLASS MEASURE DESCRIPTION WORK (YES OR NO) COMPLETE NUMBER MC Corrective PENET-XS-310 Removed gouges NO 05/1099 WO 99-01884-01 Measure MC Replacement PENET-XS-310 Welded new studs and NO 09/08/99 WO 99-01884-01 nuts MC Re lacement PENET-XS-311 Replace bent litig lug NO 05/10/99 WO 99-01884-02 MC Replacement PENET-XS-311 Welded new studs and NO 08/17/99 WO 99-01884-02 nuts.. MC Corrective PENET-XS-311 Removed gouges NO 05/10/99 WO 99-01884-02 Measures MC Corrective PENET-XS-312 Removed gouges NO 05110/99 WO 99-01884-00 Measures I MC Replacement PENET-XS-312 Welded new studs and NO 08126/99 WO 99-01884400 MC Corrective Dome Bolting Galled threads were NO 05101199 WO 98-03786-1 Measures chased with a die, machine groove and washers were ground. MC Replacement Torus Hatch Replaced studs and NO 08/17/99 WO 98-03314-04 XS-310 nuts XS-312 MC Repair PENET-X-2B Weld repair Mainsteam YES 08/26/99 WO 9901882-04 Dr~pvel Bellowss MC Replacement PENET-X-2B Cut out existing - NO 08/26/99 WO 99-01882-01 Mainsteam Drywell Bellows and weld in new belbows MC Replacement HATCH-DW-Installed (2) swingbolts NO 08/26/99 WO 95-01308-01 MC Replacement HATCH-DW-Replaced reactor NO 08/03/99 WO 98-03786-00 HEAD drywell dome bolting and w ashers File: OAR-1 WE15.WPO

Nine Mile Point Nuclear Power Station Unit I NMP1-IWE-OAR-003-01 I FIRST INSERVICE INSPECTION INTERVAL Rev. 0 NiagarajoMohawk I 1999 CONTAINMENT INSPECTION .__________________I OWNER'S ACTIVITY Date: July 17, 2001 .~~ REPORT Paae i-10 of i-11 TABLE 4 OWNER'S DATA REPORT FOR INACCESSIBLE AREAS As required by the provisions of the Code of Federal Regulaions 10 CFR 50.55a(b)(x)

1.

Owner: Niaaara Mohawk Power Corooration. 300 Erie Boulevard West, Syracuse, NY 13252 (Name and Address of Owner)

2.

Plant: Nine Mile Point-Nuclear Power Station. P.O. Box 63. Lycomina. new York 13093 (Name and Address of Plant) Plant Unit: 1 Commercial Service Date: December 26. 1969

3.

Applicable ASME Section Xl Code 1998 Edition, and NO Addenda For Class MC applications, NMPC shall evaluate the acceptability of inaccessible areas when conditions exist in accessible areas that could indicate the presence of or result in degradation to such inaccessible areas. For each inaccessible area identified, NMPC shall provide the following:

4.

Description of the type and estimated extent of degradation, and the conditions that led to the degradation; Photo documentation from previous Torus entries indicate that the waterline region may potentially exhibit generalized, non specific corrosion. Supplemental examinations will be performed from the outside surface of the Torus by taking ultrasonic thickness measurements of the Torus shell plate at the waterline region. These examinations were to determine the general Torus shell thickness and if minimum wall thickness requirements have been violated by the corrosion.

5.

An evaluation of each area, and the results of the evaluation; Engineering had determined that eight (8) locations/areas will be ultrasonically measured for thickness. Of the three hundred and sixty (360) readings taken, the lowest recorded point (o.0438 inches) was in Bay 3-I at location B6. Since the allowable minimum wall was 0.397 inches at this location, the recorded readings were found to be acceptable.

6.

Description of necessary corrective actions; No corrective actions were required File: OAR-i IWE15.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-[WE-OAR-003-01 FIRST INSERVICE INSPECTION INTERVAL Rev. 0 ma y %Moohawk g 1999 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 REPORT Paae I -I 1 of i-li End of Containment Inservice Inspection Owner's Activity Report For Refueling Outage Fifteen (RFO-15) FRe: OAR-11WE15.WPD

Niagara GQMohawl( Niagara Mohawk Power Corporation 300 Erie Boulevard West Syracuse, New York 13252 ENCLOSURE 4 FIRST INSERVICE INSPECTION INTERVAL FIRST INSERVICE INSPECTION PERIOD CONTAINMENT INSERVICE INSPECTION 2001 OWNER'S ACTIVITY REPORT Prepared For Nine Mile Point Nuclear Power Station P.O. Box 63 Lycoming, New York 13093 Commercial Service Date: NRC Docket Number: Document Number December 26, 1969 50-220 NMP1 -IWE-OAR-003-02 Revision Number: 0o Date: July 17, 2001

Nine Mile Point Nuclear Power Station Unit I NMPI-IWE-OAR-003-02 FIRST INSERVICE INSPECTION INTERVAL Rev. 0 Niagra aMohawk 2001 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 REPORT Paae i - 2 of i-11 TABLE OF CONTENTS Table of Contents....................................................................... i-2 Record of Revision. i-3 Abstract............................................................ I.................... i-4 Form OAR-1 Owner's Activity Report (2001 Refueling Outage).................................... i-6 Table 1 Abstract of Examination and Tests................................................... i-7 Table 2 Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service... ....... 1-8 Table 3 Abstract of Repairs, Replacements, or Corrective Measures Required for Continued Service... .... i-9 Table 4 Owners' Data report for Inaccessible Areas........................................... 1-10 File: OAR-1IWE16.WPD

Nine Mile Point Nuclear Power Station Unit I NMPI-IWE-OAR-003-02 Niagar M, FIRST INSERVICE INSPECTION INTERVAL Rev. 0 Niagara M]9ohawl 2001 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 REPORT Pace i - 3 of i-11 0 July 17, 2001 Entire Document Initial issue of Owner's Activity Report in accordance with the requirements of ASME Code Case N-532 in lieu of IWA-6000 as granted by USNRC Safety Evaluation, dated October 5, 2000, Request for Relief ISI-8. L L File: OAR-1 IWE1 6.WPD

'Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-02 .EC%, FIRST INSERVICE INSPECTION INTERVAL Rev., Niagmt omW2001 CONTAINMENT INSPECTION Dt:Jly 720 OWNER'S ACTIVITY Date: July 17,2001

l.

REPORT j Paae 1-4 of i-11 ABSTRACT This Owner's Activity Report summarizes the results of the Nine Mile Point Nuclear Power Station, Unit 1, First Containment Inservice Inspection Period that started on 26 December 1999 and ends on 25 December 2002. The first inservice inspection period consists of refueling outages fifteen (RFO-1 5) and sixteen (RFO-1 6). As a alternate to the requirements of the American Society of Mechanical Engineers (ASME), Boiler and Pressure Vessel Code (B&PVC), Section Xl, Article IWA-6000, NMPC submitted Request for Relief ISI-8 on October 30, 1999, under Letter NMP1 L 1480, to implement ASME Code Case N-532, "Altemative Requirements to Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000, Section Xl, Division 1". USNRC Safety Evaluation dated October 5, 2000, under TAC No. MA7129 authorized use of this alternative. IWE Containment Inservice examinations were initially performed during refueling outage (RFO-1 5), which was conducted during the period of April 6,1999 through June 16,1999. The IWE examinations consisted of examining the general condition of the Torus internal pressure retaining components at or below the waterline. The results of these inspections were documented in the RFO-1 5 Torus Inspection Plan, Document NER-1 S-025, Revision 1, and was provided in Appendix D of the 1999 Summary Report Submittal. In order to meet the intent of ASME Code Case N-532, an Owners' Activity Report Form OAR-1 was prepared to document the 1999 (RFO-15) Examination activity, and is scheduled to accompany this submittal. This Owners Activity Report Form OAR-1 and attachments were prepared and certified upon completion of the 2001 second refueling outage (RFO-16) which started on March 18, 2001 and ended on May 18, 2001. Note: Pursuant to 10 CFR 50.55a(a)(3)(i) ASME Code Case N-532 is authorized for use during the Third Ten-Year Inservice Inspection Interval, or until ASME Code Case N-532 is approved for general use by reference in 10 CFR 50.55a (previously Regulatory Guide 1.147). After that time, NMPC must follow the conditions, if any, specified in the regulation. In addition to the Owner's Activity Report, Form OAR-1, the following Tables are also included:

a.

Abstract of Examinations and Tests, Table 1, that provides such information -as ASME Code Examination Category, Total Examinations Required for the Inspection Interval, Total Examinations Required for this Period, Total Examinations Credited (%) for this Period, Total Examinations Credited (%) to Date for the Interval, and any remarks that may be applicable.

b.

Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service, Table 2, that provides a listing of item(s) with flaws or relevant conditions that required evaluation to determine acceptability for continued service, whether or not the flaw or relevant condition was discovered during a scheduled examination or test, and provides such information as Examination Category, Examination Item Number, Item Description, Flaw Characterization (as required by IWA-3300), and whether the flaw or relevant condition was found during a scheduled Section Xl examination or test.

c.

Abstract of Repairs, Replacements or Corrective Measures Required for Continued Service, Table 3, which identify those items containing flaws or relevant conditions that exceeded the NMPC defined or ASME Section Xl acceptance criteria (IWE-3000) or in the case of supports IWF-3000 acceptance criteria; even though the discovery of the flaw or relevant condition that necessitated the repair, replacement or corrective measure, may not have resulted from an File: OAR-1 IWE16.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-02 Nia Am l\\\\ Mohawk FIRST INSERVICE INSPECTION INTERVAL Rev. 0 NiagM --1) Moha k 2001 CONTAINMENT INSPECTION UN OWNER'S ACTIVITY Date: July 17, 2001 __________________I REPORT Page i-5 of i-11 examination or test required by Section Xl, and provides such information as Code Class, whether the item is a repair, replacement or corrective action, item description, description of work, if the flaw or relevant condition was found during a scheduled Section Xl Examination or test, date completed and the repair replacement plan number.

d.

Owners' Report for Inaccessible Areas, Table 4, as required by Code of Federal Regulations 10 CFR 50.55a(b)(x), provides such information as a description of the type and estimated extent of degradation, and condition that led to the degradation, description and results of the evaluations, and a description of the corrective actions. Note: If acceptance criteria for a particular item is not specified in Section Xl, the provisions of IWA-3100(b) may be used to determine which repairs, replacements, and corrective measures are required to be included in the abstract. Each Form OAR-1 and the applicable Tables were prepared for the NMP1 First Inservice Inspection Period and is being submitted following the end of the first inspection period as defined below. Although specifically not addressed in the ASME Code Case, NMPC approximate submittal date will be ninety (90) days following the end of the each specific inspection period. -Owner's'Activity ReportSubmit' Inspection Periods Inspection Period End Refueling Outage Outage Approximate, Dates Year - Submittal Date ST. period December 25, 2002 RFO-1 5 1999 RFO-16 2001 Extended 1 ST. Period April 23, 2003 RFO-1 7 2003 July 23, 2003 Extension File: OAR-1 IWE1 6.WPD

Nine Mile Point Nuclear Power Station Unit I NMPI-IWE-OAR-003-02 FIRST INSERVICE INSPECTION INTERVAL Rev. 0 Niagara INN,,,~'Mohaw k 2001 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 l REPORT Paae i-6 of i-11 FORM OAR-1 OWNER'S ACTIVITY REPORT As required by the provisions of the ASME Code Case N-532 Report Number NMP1 -IWE-OAR-003-02 Ownei Plant r Niagara Mohawk Power Corporation. 300 Erie Boulevard West. Syracuse. New York 13252 (Name and Address of Owner) Nine Mile Point Nuclear Power Station. P. 0. Box 63. Lvcomina. New York 13093 (Name and Address of Plant) Commercial Service Date December 26. 1969 Refueling Outage Number RFO-16 Plant Unit 1 Current Inspection Interval First Inservice Insgection Interval - December26. 1999 to December 25. 2009 (1st, 2nd, 3rd, 4th, Other) Current Inspection Period First Inservice Inswection Period - December 26. 1999 to December 25. 2002 (1st, 2nd, 3rd) Edition and Addenda of Section Xi applicable to the Inspection Plan 1998 Edition. No Addenda Date and Revision of Inspection Plan NMP1-IWE-003-1 0. Revision 1. Dated September 4. 2000 Edition and Addenda of ASME Section Xi applicable to Repairs and Replacements, if different than the Inspection Plan N/A CERTIFICATE OF CONFORMANCE I certify that the statements made in this Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations and corrective measures represented by this report conform to the requirements of Section Xl. Certificate of Authorization No. N/A Expiration Date N/A A, O pplicaby Signe d_ -*Date-7_ (Supervisor ASME Section Xl Programs Group) CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York and employed by Factory Mutual Insurance Company of Johnston. Rhode Island have inspected the items described in this Owners Activity Report, during the period March 18 2001 to May 18. 2001 and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations and corrective measures described in this report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. C;&-6 Commissions NB 8496 V Inspectors Signature National Board, State, Province, and Endorsements Date 7 L; ( 20 ° / File: OAR-1 IWE16.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMPI-IWE-OAR-003-02 ,iar 'm o m FIRST INSERVICE INSPECTION INTERVAL Rev. 0 NigagraRLE M0113A~ 2001 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 REPORT Paae i-7 of i-11 TABLE I ABSTRACT OF EXAMINATION AND TESTS As required by the provisions of the ASME Code Case N-532 TOTAL TOTAL TOTAL TOTAL EXAMINATIONS CODE EXAMINATIONS EXAMINATIONS EXAMINATIONS CREDITED (%) EXAMINATION REQUIRED FOR. REQUIRED FOR THIS CREDITED (%) FOR THE TO REMARKS CATEGORY INTERVAL PERIOD PERIOD DATE FOR THE R ________________IN TERVA L E-A 2322 897 100% 38.6% E-C 0 0 0% 0% F-A 10 2 100% 20% ASME CODE CASE N491-1 I I I I I I File: OAR-1 IWE1 6.WPD

Nine Mile Point Nuclear Power Station Unit I NMP1-IWE-OAR-003-02 FIRST INSERVICE INSPECTION INTERVAL Rev. 0 Niaga3ra .) Mohawk 2001 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 REPORT o Paoe i - 8 of i-1 TABLE 2 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRE EVALUATION FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT FLAW CONDITION EXAMINATION ITEM ITEM CHARACTERIZATION FOUND DURING CATEGORY NUMBER DESCRIPTION (IWA-3300) SCHEDULED SECTION XI EXAMINATION OR TEST (YES OR NO) E-A E1.30 Containment Drywell Moisture Barrier Missing or Degraded Sealant Yes E-A E1.1 1 Drywell Equipment Hatch Arc Strikes Yes E-A E1.1 1 Drywell Head Hatch Gouges Yes l E-A E1.11 Torus Outside Surface Arc Strikes Yes File: OAR-1i1WE16.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-4WE-OAR-003-02 E FIRST INSERVICE INSPECTION INTERVAL Rev. 0 Niagarad WMoha k2001 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: July 17, 2001 REPORT Paae i-9 of i-11 TABLE 3 ABSTRACT OF REPAIRS, REPLACEMENTS OR CORRECTIVE MEASURES REQUIRED FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT CONDITION FOUND REPAIR DURING SCHEDULED REPAIR REPLACEMENT DESCRIPTION SECTION XI REPLACEMENT CODE OR CORRECT VE ITEM OF - EXAMINATION OR TEST DATE PLAN CLASS MEASURE DESCRIPTION WORK (YES OR NO) COMPLETE NUMBER MC Corrective Moisture Replace missing Yes 04111101 WO 01-01970-00 Measure Barrier or degraded ____seala n t L I _I I I_ I__ _ I _ I I File: OAR-11 IWE16.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMPI-IWE-OAR-003-02 Niagaa .FIRST INSERVICE INSPECTION INTERVAL Rev. o Nlagira MohawR 2001 CONTAINMENT INSPECTIONDate Ju o OWNER'S ACTIVITYDaeJuy1,20 l ~~~~~~~~~REPORT Paae 0 of i -1i1 TABLE 4 OWNER'S DATA REPORT FOR INACCESSIBLE AREAS As required by the provisions of the Code of Federal Regulations 10 CFR 50.55a(b)(x)

1.

Owner: Niagara Mohawk Power Corporation, 300 Erie Boulevard West, Syracuse. NY 13252 (Name and Address of Owner)

2.

Plant: Nine Mile Point Nuclear Power Station. P.O. Box 63. Lycoming. new York 13093 (Name and Address of Plant) Plant Unit: 1 Commercial Service Date: December 26. 1969

3.

Applicable ASME Section Xl Code 1998 Edition, and NO Addenda' For Class MC applications, NMPC shall evaluate the acceptability of inaccessible areas when conditions exist in accessible areas that could indicate the presence of or result in degradation to such inaccessible areas. For each inaccessible area identified, NMPC shall provide the following:

4.

Description of the type and estimated extent of degradation, and the conditions that led to the degradation; During scheduled inservice examination of the containment moisture barrier between the dry well liner and the concrete floor at elevation 225-ft was identified as portions of the sealant was either missing and those portions of the existing sealant was degraded. The moisture barrier was degraded over the entire 360 degree circumference, with approximately 60% of the moisture barrier being missing.

5.

An evaluation of each area, and the results of the evaluation; Detailed Visual examination found no unacceptable degradation in the visible areas of the dry well liner adjacent to the moisture barrier. Evaluation of the inaccessible areas of the Containment Liner condition below the concrete is not possible without breaking and removal of the concrete. Engineering evaluation of this condition is that a significant portion of the existing barrier is still in good condition and requires corrective actions to be fully effective to function as a moisture barrier.

6.

Description of necessary corrective actions; Restore containment moisture barrier to original intended function by repairing degraded portions and replacing missing portions of moisture barrier. File: OAR-1 IWEI6.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-02 .cb, FIRST INSERVICE INSPECTION INTERVAL Rev. 0 Niagara NNMhaW 2001 CONTAINMENT INSPECTION I ^ \\l\\OWNER'S ACTIVITY Date: July 17,2001 __________________j REPORT I Peae I-11 of I -1 1 End of Containment Inservice Inspection Owner's Activity Report For Refueling Outage Sixteen (RFO-16) File: OAR-1 IWE16.WPD

Constellation Energy Group Nine Mile Point Nuclear Station Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lake Road Lycoming, New York 13093 ENCLOSURE 5 THIRD INSERVICE INSPECTION INTERVAL FIRST INSERVICE INSPECTION PERIOD 2003 OWNER'S ACTIVITY REPORT FOR INSERVICE SYSTEM PRESSURE TESTING Prepared For Nine Mile Point Nuclear Station P.O. Box 63 Lycoming, New York 13093 Commercial Service Date: NRC Docket Number: Document Number December26, 1969 50-220 NMP1 -SPT-OAR-003-02 Revision Number 00 Date:April 23, 2003

Nine Mile Point Nuclear Station Unit 1 NMP1-SPT-OAR-003-02 ConsteatiTHIRD INSERVICE INSPECTION INTERVAL Rev. 00 0 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Wle Point FOR Date: Aprp 23, 2003 Nudear Station INSERVICE SYSTEM PRESSURE TESTING Page 1-2 of 1-10. TABLE OF CONTENTS Table of Contents............ i-2 Record of Revision............ i-3 Abstract............ i-4 Form OAR-1 Owner's Activity Report for Inspection Plan NMP1 -PT-003 (2003 Refueling Outage)... i-7 Table 1 Abstract of Examination and Tests.................................................... i-8 Table 2 Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service... i-9 Table 3 Abstract of Repairs, Replacements, or Corrective Measures Required for Continued Service..... i-1 0 File: OAR-11S117.WPD

Nine Mile Point Nuclear Station Unit 1 NMPl-SPT-OAR-003-02 &4r'I' Con-istellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine tne Point FOR. Date: April 23, 2003 Nudear Station INSERVICE SYSTEM PRESSURE TESTING =~~ Page 1-3 of 1-10 File: OAR-11S117.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-SPT-OAR-003-02 THIRD INSERVICE INSPECTION INTERVAL Rev. 00 0 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine We Point FOR Date: April 23, 2003 Nuclear Station INSERVICE SYSTEM PRESSURE TESTING l __________________ l________________________________ _Page 1-4 of 1-10 ABSTRACT This Owners Activity Report supplements report NMP1 -ISI-OAR-003-01 of the Nine Mile Point Nuclear Station (NMPNS), Unit 1, ASME Section Xl Inservice System Pressure Testing performed during the First Refueling Outage (RFO-1 6) of the First Inservice Inspection Period that started on 26 December 1999 and was scheduled to end on 25 December 2002. This report incorporates the remaining First Inspection Period remaining Pressure Tests required for close-out. As an alternate to the requirements of the American Society of Mechanical Engineers (ASME), Boiler and Pressure vessel Code (B&PVC), Section XI, Article IWA-6000, NMPNS submitted Request for Relief ISI-8 on October 30, 1999, under Letter NMP1 L 1480, to implement ASME Code Case N-532, "Alternative Requirements to Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000, Section XI, Division 1'. USNRC Safety Evaluation dated October 5, 2000, under TAC No. MA7129 authorized use of this alternative. An Owners Activity Report Form OAR-1, was prepared and certified upon completion of the 2003 refueling outage (RFO-1 7) Examination activity. Note: Pursuant to 10 CFR 50.55a(a)(3)(i) ASME Code Case N-532 is authorized for the Third Ten-Year Inservice Inspection Interval, or until ASME Code Case N-532 is approved for general use by reference in 10 CFR 50.55a (previously Regulatory Guide 1.147). After that time, NMPNS must follow the conditions, if any, specified in the regulation. In addition to the Owners Activity Report, Form OAR-1, the following Tables are also included:

a.

Abstract of Examinations and Tests, Table 1, provides such information as ASME Code Examination Category, Total Examinations Required for the Inspection Interval, Total Examinations Required for this Period, Total Examinations Credited (%) for this Period, Total Examinations Credited (%) to Date for the Interval, and any remarks that may be applicable.

b.

Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service, Table 2, provides a listing of item(s) with flaws or relevant conditions that required evaluation to determine acceptability for continued service, whether or not the flaw or relevant condition was discovered during a scheduled examination or test, and provides such information as Examination Category, Examination Item Number, Item Description, Flaw Characterization (as required by IWA-3300), and whether the flaw or relevant condition was found during a scheduled Section Xl examination or test.

c.

Abstract of Repairs, Replacements or Corrective Measures Required for Continued Service, Table 3, identifies those items containing flaws or relevant conditions that exceeded the ASME Section Xl acceptance criteria (IWX-3000) or in the case of supports IWF-3000 acceptance criteria; even though the discovery of the flaw or relevant condition that necessitated the repair, replacement or corrective measure, may not have resulted from an examination or test required by Section Xl, and provides such information as Code Class, whether the' item is a repair, replacement or corrective action, item description, description of work, if the flaw or relevant condition was found during a Fle: OAR-11S117.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-SPT-OAR-003-02 O Consellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 uW Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Wile Point FOR Date: April 23, 2003 Nuclear Station INSERVICE SYSTEM PRESSURE TESTING I ____________'_____ Page 1-5 of 1-10 In accordance with ASME Section Xl, IWB-2412 (a), with the exception of the examinations that may be deferred until the end of the inspection interval as specified in Table IWB-2500-1, the required examinations in each examination category shall be completed during each successive inspection interval in accordance with Table IWB-2412-1, and per IWB-2412 (b) the inspection period specified in (a) above may be decreased or extended by as much as 1 year to enable an inspection to coincide with a plant outage, within the limitations of IWA-2430(d). Although specifically not addressed in the ASME Code Case, NMPNS approximate submittal date will be ninety (90) days following the end of each specific inspection period. File: OAR-11Sl17.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-SPT-OAR-003-02 Comstellaftn THIRD INSERVICE INSPECTION INTERVAL Rev. 00 NL Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Wle Point FOR Date: April 23, 2003 Nuclear Station INSERVICE SYSTEM PRESSURE TESTING Page 1-6 of 1-10 FORM OAR-1 OWNER'S ACTIVITY REPORT As required by the provisions of the ASME Code Case N-532 Report Number NMP1 -SPT-OAR-003-01 -A Owner Nine Mile Point Nuclear Station. LLC. P.O. Box 63 Lake Road. Lycomina. New York 13093 (Name and Address of Owner) Plant Nine Mile Point Nuclear Station. P. 0. Box 63. Lycomina. New York 13093 (Name and Address of Plant) Plant Unit 1 Commercial Service Date December 26. 1969 Refueling Outage Number RFO-1 7 Current Inspection Interval Third Inservice Insoection Interval - December 26. 1999 to December 25. 2009 (1 st, 2nd, 3rd, 4th, Other) Current Inspection Period First Inservice Inspection Period - December 26. 1999 to December 25. 2002 (1 st, 2nd, 3rd) Edition and Addenda of Section Xi applicable to the Inspection Plan 1989 Edition. No Addenda Date and Revision of Inspection Plan NMPI-PT-003. Revision 1. Dated March 1. 2001 Edition and Addenda of ASME Section Xi applicable to Repairs and Replacements, If different than the Inspection Plan N/A CERTIFICATE OF CONFORMANCE I certify that the statements made in this Owners Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations and corrective measures represented by this report conform to the requirements of Section Xl. Certificate of Authorization No. N/A Expiration Date /~~~~~~~~~11 a4~pplicable) Signed He- /' ( ) k Date i;/ (Principal Enaineer - ASME Section Xl Proarams Grouo) N/A IZ3g Ai CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York and employed by Factory Mutual Insurance Comoanv of Johnston. Rhode Island, have inspected the Items described In this Owner's Activity Report, during the period March 14. 2003 to Acril 23. 2003 and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations and corrective measures described in this report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. gj 9 Commissions NB 8496 Cl' Inspectors Signature National Board, State, Province, and Endorsements Date e jL+/-2 O t 2 v3 File: OAR-11S117.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-SPT-OAR-003-02 OConsellation THIRD INSER VICE INSPECTION INTERVAL Rev. 00 0 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Wle Point FOR Date: April 23, 2003 Nuclear Stion INSERVICE SYSTEM PRESSURE TESTING .Page 1-7 of i-10 TABLE 1 ABSTRACT OF EXAMINATION AND TESTS As required by the provisions of the ASME Code Case N-532 TOTAL TOTAL TOTAL TOTAL EXAMINATIONS CODE EXAMINATIONS EXAMINATIONS EXAMINATIONS CREDITED (%) TO EXAMINATION REQUIRED FOR REQUIRED FOR CREDITED (%) DATE FOR THE CATEGORY INTERVAL THIS PERIOD FOR THE PERIOD INTERVAL REMARKS B-E 2 0 0 -0% 0% Deferral Permissible B-P N/A N/A 97-N/A N/A Excluded from Insp. Prog. 'B' C-H N/A N/A 20-N/A N/A Excluded from Insp. Prog. 'B' D-A N/A N/A 14 - N/A N/A Excluded from Insp. Prog. m6" G-L-G 100 20 20-100% 20-20% Inaccessible Welds File: OAR-1 ISI17.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-SPT-OAR-003-02 Constelblaion THIRD INSERVICE INSPECTION INTERVAL Rev. 00 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Mie PoinEtFOR Date: April 23, 2003 Nudear Station INSERVIC SYSTEM PRESSURE TESTING Page 1-8 of 1-10 ITEMS WITH FLAWS OR TABLE 2 RELEVANT CONDITIONS THAT REQUIRE EVALUATION FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 I FLAW OR RELEVANT I - FLAW CONDITION EXAMINATION ITEM ITEM CHARACTERIZATION FOUND DURING CATEGORY NUMBER DESCRIPTION ([WA-3300) I SCHEDULED I I ~~~~~~SECTION Xi EXAMINATION OR TEST l (Y ES O R N O ) NONE File: OAR-11S117.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-SPT-OAR-003-02 1 Coanstel6ion THIRD INSERVICE INSPECTION INTERVAL Rev. 00 l Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Mile Point FOR. Date: April 23, 2003 Nuclear Staton INSERVICE SYSTEM PRESSURE TESTING I ___________________. Page 1-9 of 1-10 . TABLE 3 ABSTRACT OF REPAIRS, REPLACEMENTS, OR CORRECTIVE MEASURES REQUIRED FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT REPAIR CONDITION FOUND REPLACEMENT DURING SCHEDULED REPAIR OR DESCRIPTION SECTION Xi REPLACEMENT CODE CORRECTIVE ITEM OF EXAMINATION OR TEST DATE PLAN CLASS MEASURE DESCRIPTION WORK (YES OR NO) COMPLETE NUMBER No Repairs/Re lacements or Corrective Measures R uired File: OAR-I1SI17.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-SPT-OAR-003-02 .Con adon THIRD INSERVICE INSPECTION INTERVAL Rev. 00 Energy Group 2003 OWNERS' ACTIVITY REPORT Nie Mile Point FOR Date: April 23, 2003 NuclearStation INSERVICE SYSTEM PRESSURE TESTING Page 1-10 of 1-10 End of Inservice System Pressure Testing Owner's Activity Report For Refueling Outage Seventeen (RFO-17) File: OAR-11S117.WPD

Constellation I Energy Group Nine Mile Point Nuclear Station Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lake Road Lycoming, New York 13093 ENCLOSURE 6 THIRD INSERVICE INSPECTION INTERVAL SECOND INSERVICE INSPECTION PERIOD 2003 OWNER'S ACTIVITY REPORT FOR INSERVICE EXAMINATIONS Prepared For Nine Mile Point Nuclear Station P.O. Box 63 Lycoming, New York 13093 Commercial Service Date: NRC Docket Number: Document Number December 26, 1969 50-220 NMP1 -ISI-OAR-003-02 Revision Number: 00 Date:April 23, 2003

Nine Mile Point Nuclear Station Unit 1 l NMP1-ISI-OAR-003-02 THIRD INSERVICE INSPECTION INTERVAL Rev. 00 Energy Group 2003 OWNERS' ACTIVITY REPORT Nie nerPoin FOR Date: April 23, 2003 NudearStation INSERVICE EXAMINATIONS Page 1-2 of I-11 TABLE OF CONTENTS Table of Contents.................. i-2 Record of Revision. i-3 Abstract................... i-4 Form OAR-1 Owner's Activity Report for Inspection Plan NMP1-ISI-003 (2003 Refueling Outage)....... i-7 Table 1 Abstract of Examination and Tests.................................................... i-8 Table 2 Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service.......... i-9 Table 3 Abstract of Repairs, Replacements, or Corrective Measures Required for Continued Service...... i-10 File: OAR-11SI17.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-02 ONA C~oms~tella-tion THIRD INSERVICE INSPECTION INTERVAL Rev. 00 CoEnemy Group 2003 OWNERS' ACTIVITY REPORT Nine Wyle FintFOR Date: April 23, 2003 NuclearStation INSERVICE EXAMINATIONS I Page 1-3 of i-11 E$ECOA_ XII

REmASONR E

00 April 23, 2003 Entire Document Initial issue of Owner's Activity Report for ASME Section Xl Inservice Examinations in accordance wvith the requirements of ASME Code Case N-532 in lieu of IWA-6000 as granted by USNRC Safety Evaluation, dated October 5, 2000, Request for Relief ISI-8. 1 1 File: OAR-lISl17.WPD

Nine Mile Point Nuclear Station Unit 1 NMPI-ISI-OAR-003-02 THIRD INSERVICE INSPECTION INTERVAL Rev. 00 0 Constellation 2003 OWNERS' ACTIVITY REPORT Nine Wie Point FOR Date: April 23, 2003 Nuclear Station INSERVICE EXAMINATIONS Page 1-4 of i-11 ABSTRACT This Owner's Activity Report summarizes the results of the Nine Mile Point Nuclear Station (NMPNS), Unit 1, ASME Section Xl Inservice Examinations performed during the First Refueling Outage (RFO-17) of the Second Inservice Inspection Period that started on 26 December 2002 and is scheduled to end on 25 December 2006. As an alternate to the requirements of the American Society of Mechanical Engineers (ASME), Boiler and Pressure vessel Code (B&PVC), Section XI, Article IWA-6000, NMPNS submitted Request for Relief ISI-8 on October 30, 1999, under Letter NMP1 L 1480, to implement ASME Code Case N-532, "Alternative Requirements to Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000, Section Xl, Division 1'. USNRC Safety Evaluation dated October 5, 2000, under TAC No. MA7129 authorized use of this alternative. An Owner's Activity Report Form OAR-1, was prepared and certified upon completion of the 2003 refueling outage (RFO-17) Examination activity. Note: Pursuant to 10 CFR 50.55a(a)(3)(i) ASME Code Case N-532 is authorized for the Third Ten-Year Inservice Inspection Interval, or until ASME Code Case N-532 is approved for general use by reference in 10 CFR 50.55a (previously Regulatory Guide 1.147). After that time, NMPNS must follow the conditions, if any, specified in the regulation. In addition to the Owner's Activity Report, Form OAR-1, the following Tables are also included:

a.

Abstract of Examinations and Tests, Table 1, provides such information as ASME Code Examination Category, Total Examinations, Required for the Inspection Interval, Total Examinations Required for this Period, Total Examinations Credited (%) for this Period, Total Examinations Credited (%) to Date for the Interval, and any remarks that may be applicable.

b.

Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service, Table 2, provides a listing of item(s) with flaws or relevant conditions that required evaluation to determine acceptability for continued service, whether or not the flaw or relevant condition was discovered during a scheduled examination or test, and provides such information as Examination Category, Examination Item Number, Item Description, Flaw Characterization (as required by IWA-3300), and whether the flaw or relevant condition was found during a scheduled Section Xl examination or test.

c.

Abstract of Repairs, Replacements or Corrective Measures Required for Continued Service, Table 3, identifies those items containing flaws or relevant conditions that exceeded the ASME Section Xl acceptance criteria (IWX-3000) or in the case of supports IWF-3000 acceptance criteria; even though the discovery of the flaw or relevant condition that necessitated the repair, replacement or corrective measure, may not have resulted from an examination or test required by Section Xl, and provides such information as Code Class, whether the item is a repair, replacement or corrective action, item description, description of work, if the flaw or relevant condition was found during a scheduled Section Xl Examination or test, date completed and the repair replacement plan number. File: OAR-11SI17.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-02 Constellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 0 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Nie Point FOR I Date: April 23, 2003 Nudear Station INSERVICE EXAMINATIONS Page i-5 of i-11 In accordance with ASME Section Xl, IWB-2412 (a), with the exception of the examinations that may be deferred until the end of the inspection interval as specified in Table IWB-2500-1, the required examinations in each examination category shall be completed during each successive inspection interval in accordance with Table IWB-2412-1, and per IWB-2412 (b) the inspection period specified in (a) above may be decreased or extended by as much as 1 year to enable an-inspection to coincide with a plant outage, within the limitations of IWA-2430(d). Although specifically not addressed in the ASME Code Case, NMPNS approximate submittal date will be ninety (90) days following the end of each specific inspection period. File: OAR-i1SI17.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-lSI-OAR-003-02 A~. Conste~atTHIRD INSERVICE INSPECTION INTERVAL Rev. 00 C Energy Group 2003 OWNERS' ACTIVITY REPORT Nine NiO Point FOR Date: April 23, 2003 Nuclear Station INSERVICE EXAMINATIONS Page 1-6 of 1-11 FORM OAR-1 OWNER'S ACTIVITY REPORT As required by the provisions of the ASME Code Case N-532 Report Number NMP1 -ISI-OAR-003-02 Owner Nine Mile Point Nuclear Station. LLC. P.O. Box 63 Lake Road. Lycomina. New York 13093 (Name and Address of Owner) Plant Nine Mile Point Nuclear Station. P. O. Box 63. Lvcomino. New York 13093 (Name and Address of Plant) Plant Unit 1 Commercial Service Date December 26.1969 Refueling Outage Number RFO-17 Current Inspection Interval Third Inservice Inspection Interval - December 26.1999 to December 25.2009 (1st, 2nd, 3rd, 4th, Other) Current Inspection Period Second Inservice Inspection Period - December 26. 2002 to December 25.2006 (1 st, 2nd, 3rd) Edition and Addenda of Section Xl applicable to the Inspection Plan 1989 Edition. No Addenda Date and Revision of Inspection Plan NMP1-ISI-003. Revision 2. Dated September 25.22002 Edition and Addenda of ASME Section Xi applicable to Repairs and Replacements, If different than the Inspection Plan N/A CERTIFICATE OF CONFORMANCE I certify that the statements made in this Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements. evaluations and corrective measures represented by this report conform to the requirements of Section Xl. Certificate of Authorization No. N/A Expiration Date N/A -414 /2 g:~ plicable) Signed AL-g t -{ v /J

7J Date (Principal Engineer-ASME Section Xl Programs Group)

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York and employed by Factory Mutual Insurance Comoany of Johnston. Rhode Island have inspected the items described in this Owneres Activity Report, during the period March 14. 2003 to Aoril 23.2003 and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations and corrective measures described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. 2t CL Commissions NB 8496 C' Inspector's Signature National Board, State, Province, and Endorsements Date 4 1I9-f-20 03 File: OAR-1 1S117.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-02 Consitellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 oEnergy Group 2003 OWNERS' ACTIVITY REPORT Nine We Point FOR Date: April 23, 2003 Nudear Station INSERVICE EXAMINATIONS Page 1-7 of i-11 TABLE 1 ABSTRACT OF EXAMINATION AND TESTS As required by the provisions of the ASME Code Case N-532 TOTAL TOTAL 'TOTAL TOTAL EXAMINATIONS CODE EXAMINATIONS EXAMINATIONS EXAMINATIONS CREDITED (%) TO EXAMINATION REQUIRED FOR REQUIRED FOR CREDITED (%) DATE FOR THE CATEGORY INTERVAL THIS PERIOD FOR THE PERIOD INTERVAL REMARKS B-A 42 4 4-100% 29% Deferral Permissible B-D 82 25 2-.8% 28.0% Deferral Permissible B-E 2 0 0-0% 0% Deferral Permissible B-F N/A N/A NIA N/A Under Risk-Informed B-G-1 411 135 126 - 93% 65% Insp. Prog. B Compliance B-G-2 93 48 25 - 520% 54.8% Insp. Prog. B Compliance B-J N/A N/A N/A N/A Under Risk-Informed B-K 13 5 2 - 40% 30.7%°h B-L-2 1 1 0 - 0% 0% Deferral Permissible B-M-1 1 1 0 - 0% 0% Deferral Permissible B-M-2 18 11 3 - 27%/ 38.8% Deferral Permissible B-N-1 30 12 8 -67% 56.6% B-N-2 28 12 10 - 83% 53.5% Deferral Permissible 8-0 8 5 0 - 0% 0% Deferral Permissible B-P N/A 195 110-56.4% N/A Excluded from Insp. Prog. 'B' C-A 4 1 1 - 100% 50% Insp. Prog. 'B' Compliance C-B 4 1 1 -100% 50% Insp. Prog. 'BE Compliance C-C 32 10 9 - 90% 59% Insp. Prog. 1B Compliance C-F-1 N/A N/A N/A NVA Under Risk-Informed C-F-2 N/A N/A N/A N/A Under Risk-Informed C-G 19 9 2 - 22% 42% Deferred Per RR-ISI-7 C-H N/A N/A 0-0% N/A Excluded from Insp. Prog. B' D-A 25 5 5 - 100% 52% Insp. Prog. B" Compliance F-A 186 70 41 - 58.5% 49% R-A 63 39 8 - 20.5% 12.6% .1. .5. .1 File: OAR-11S117.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-02 XSob ContelLaon THIRD INSERVICE INSPECTION INTERVAL Rev. 00 .%-ffC Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Mie Point FOR Date: April 23, 2003 Nuclear Station INSERVICE EXAMINATIONS Page i-8 of I-1I TABLE 2 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRE EVALUATION FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT FLAW CONDmON EXAMINATION ITEM ITEM CHARACTERIZATION FOUND DURING CATEGORY NUMBER DESCRIPTION (IWA-3300) SCHEDULED SECTION XI EXAMINATION OR TEST _ _(Y E S O R N O ) B-A 8122 RV-WD-005 Cloyrip Head Meridional Sub-surface Yes F-A F1.10 Grout eroded on all four sides Condition Yes C-C C3.20 80-SC-20 Integral Attachment LUnear Indication Yes F-A F1.20 81-H37 Spring Hanger Position inlicntor outside Yes sca e Imit B-N-1 B13.10 RPV-03-1-CH.RPy Closure Head (12) Linear Indications Yes interior burnace File: OAR-11S117.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-lSI-OAR-003-02 Costellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 Energy Group 2003 OWNERS' ACTIVITY REPORT Nine Mile Point FOR Date: April 23, 2003 NucearStation INSERVICE EXAMINATIONS I I_ Page 1-9 of i-11 TABLE 3 ABSTRACT OF REPAIRS, REPLACEMENTS, OR CORRECTIVE MEASURES REQUIRED FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT REPAIR CONDITION FOUND REPLACEMENT DURING SCHEDULED REPAIR OR DESCRIPTION SECTION XI REPLACEMENT CODE CORRECTIVE ITEM OF EXAMINATION OR TEST DATE PLAN CLASS MEASURE DESCRIPTION WORK (YES OR NO) COMPLETE NUMBER 1 Replacement SRV Studs Relief Valve Bolting No 03/23/03 WO 01-08426-00 1 Repair IV-01-01 Stellite Overlay No 03127/03 WO 02-07572-00 1 Replacement IV-01-01-VB Replaced studs and No 03/24/03 WO 02-07572-00 1 Replacement IV-01-04-VB Replaced studs and No 03124/03 WO 02-01681-09 nuts 1 Replacement CKV-31 -01 R-VB Replaced studs No 03/28/03 WO 02-04849-00 1 Replacement CKV-31-011R-Replaced nuts and No 03/26/03 WO 02-04849-00 VNW washers 1 Replacement 32-191-SHB Replaced seal No 03/18/03 WO 02-04162-01 housing bolting 1 Replacement CX-32-513 Replaced Decon No 03/27/03 WO 02-01489-06 flange bolting 1 Replacement 37-WD-002-FB Replaced flange No 03/24/03 WO 01-05712-01 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _b o l t i n g 1 Repair CKV-39-04-VBY Sealing surface No 03120/03 WO 01-03197-00 1 Replacement 32-MS-11 Replaced Snubber No 03/18/03 WO 01-08436-00 1 Replacement 32-MS-23 Replaced Snubber No 03118/03 WO 01-08295-00 1 Replacement CRD-Al-B Replaced Capscrews No 03116/03 WO 02-05630-00 1 Replacement CRD-C2-B Replaced Capscrews No 03/16/03 WO 01-07909-01 1 Replacement CRD-02-B Replaced Capscrews No 03/16/03 WO 02-03946-00 1 Replacement CRD-Fl-B Replaced Capscrews No 03/16/03 WO 02-03947-01 1 Replacement CRDG4-B Replaced Capscrews No 03/16/03 WO 02-03969-01 1 Replacement CRD-H3-B Replaced Capscrews No 03116103 WO 02-06691 -01 i Replacement CRD-L4-B Replaced Capscrews No 03/16/03 WO 02-07692-00 1 Replacement CRD-M3-B Replaced Capscrews No 03/16/03 WO 02-06574-00 0 1 Replacement CRD-M4-B Replaced Capscrews No 03/16/03 WO 02-03942-00 1 Replacement CRD-M6-B Replaced Capscrews No 03/16/03 WO 01-05060-00 1 Replacement CAD-N2-B Replaced Capscrews No 03/16/03 WO 02-03948-00 1 Replacement CRD-02-B Replaced Capscrews No 03/16/03 WO 03-016300 1 Replacement CRD-R7-B Replaced Capscrews No 0316/03 WO 0657-00 1 Replacemen R-7B RdcdCpresN 03161603 WO 02-06575-00 File: OAR-1 IS117.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-02 ~ Constellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 oEnergy Group 2003 OWNERS' ACTIVITY REPORT Nine We PoitFOR Date: April 23, 2003 Nuclear Station INSERVICE EXAMINATIONS Page 1-10 of 11 FLAW OR RELEVANT REPAIR CONDITION FOUND REPLACEMENT DURING SCHEDULED REPAIR OR DESCRIPTION SECTION Xi REPLACEMENT CODE CORRECTIVE ITEM OF EXAMINATION OR TEST DATE PLAN CLASS MEASURE DESCRIPTION WORK (YES OR NO) COMPLETE NUMBER 1 Replacement CRD-U4-1 Replaced Capscrews No 03/16/03 WO 02-08285-00 1 Replacement CRD-X-B Replaced Capscrews No 03/16/03 WO 02-03943-00 2 Replacement 80-MS-04 Replaced Snubber No 03/16/03 WO 01-08439-00 2 Replacement 44.2-MS-07 Replaced Snubber No 03/16/03 WO 01-08440-00 File: OAR-1S]17.WPD

Nine Mile Point Nuclear Station Unit 1 NMP1-ISI-OAR-003-02 fad Constellation THIRD INSERVICE INSPECTION INTERVAL Rev. 00 0 Energy Group 2003 OWNERS' ACTIVITY REPORT Mine Mie Point FOR Date: April 23, 2003 Nudear Station INSERVICE EXAMINATIONS Page i-1l1 of i-11 End of Inservice Inspection Owner's Activity Report For Refueling Outage Seventeen (RFO-17) File: OAR-i1S117.WPD

Constellation I Energy Group Nine Mile Point Nuclear Station Nine Mile Point Nuclear Station, LLC P.O. Box 63, Lake Road Lycoming, New York 13093 ENCLOSURE 7 FIRST INSERVICE INSPECTION INTERVAL SECOND INSERVICE INSPECTION PERIOD 2003 OWNER'S ACTIVITY REPORT FOR CONTAINMENT INSERVICE EXAMINATIONS Prepared For Nine Mile Point Nuclear Power Station P.O. Box 63 Lycoming, New York 13093 Commercial Service Date: NRC Docket Number: Document Number: December 26, 1969 50-220 NMP1 -IWE-OAR-003-03 Revision Number: 00 Date: April 23, 2003

Nine Mile Point Nuclear Power Station Unit 1 NMP1-[WE-OAR-003-03 FIRST INSERVICE INSPECTION INTERVAL Rev. 00 2003 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: April 23, 2003 =I. REPORT Page 1-2 of i-11i I TABLE OF CONTENTS Table of Contents.......................................................................... i-2 Record of Revision........................................................................ i-3 Abstract.i-................................................................................. i-4 Form OAR-1 Owner's Activity Report NMP1 -1WE-003 (2003 Refueling Outage)....................... i-6 Table 1 Abstract of Examination and Tests...................................................... i-7 Table 2 Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service... i-8 Table 3 Abstract of Repairs, Replacements, or Corrective Measures Required for Continued Service...... i-9 Table 4 Owners' Data report for Inaccessible Areas.............................................. 1-10 File: OAR-11WE17.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-03 F7~7] I FIRST INSERVICE INSPECTION INTERVAL Rev. 00 2003 CONTAINMENT INSPECTION K OWNER'S ACTIVITY Date: April 23, 2003 REPORT________________ Paae 1-3 of i-l1 File: OAR-i 1WE17.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-03 FIRST INSERVICE INSPECTION INTERVAL Rev. 00 2003 CONTAINMENT INSPECTION OWNER'S ACTIVITY Date: April 23, 2003 REPORT Page 1-4 of i-11 ABSTRACT This Owner's Activity Report and associated Tables summarizes the results of the Nine Mile Point Nuclear Station, Unit 1, Second Containment Inservice Inspection Period that started on 25 December 2002 and ends on 26 December 2006. The second inservice inspection period consists of refueling outages seventeen (RFO-17) and eighteen (RFO-1 8). As a alternate to the requirements of the American Society of Mechanical Engineers (ASME), Boiler and Pressure Vessel Code (B&PVC), Section Xl, Article IWA-6000, NMPNS submitted Request for Relief ISI-8 on October 30, 1999. under Letter NMP1 L 1480, to implement ASME Code Case N-532, "Alternative Requirements to. -Repair and Replacement Documentation Requirements and Inservice Summary Report Preparation and Submission as Required by IWA-4000 and IWA-6000, Section Xl, Division 1w. USNRC Safety Evaluation dated October 5, 2000, under TAC No. MA7129 authorized use of this alternative. This Owner's Activity Report Form OAR-1 and associated Tables were prepared and certified upon completion of the 2003 third refueling outage (RFO-1 7) Examination activity. Note: Pursuant to 10 CFR 50.55a(a)(3)(i) ASME Code Case N-532 is authorized for use during the Third Ten-Year Inservice Inspection Interval, or until ASME Code Case N-532 is approved for general use by reference in 1 0 CFR 50.55a (previously Regulatory Guide 1.147). After that time, NMPNS must follow the conditions, if any, specified in the regulation. In addition to the Owner's Activity Report, Form OAR-1, the following Tables are also included:

a.

Abstract of Examinations and Tests, Table 1, that provides such information as ASME Code Examination Category, Total Examinations Required for the Inspection Interval, Total Examinations Required for this Period, Total Examinations Credited (%) for this Period, Total Examinations Credited (%) to Date for the Interval, and any remarks that may be applicable.

b.

Items with Flaws or Relevant Conditions that Require Evaluation for Continued Service, Table 2, that provides a listing of item(s) with flaws or relevant conditions that required evaluation to determine acceptability for continued service, whether or not the flaw or relevant condition was discovered during a scheduled examination or test, and provides such information as Examination Category, Examination Item Number, Item Description, Flaw Characterization (as required by IWA-3300), and whether the flaw or relevant condition was found during a scheduled Section XI examination or test.

c.

Abstract of Repairs, Replacements or Corrective Measures Required for Continued Service, Table 3, which identify those items containing flaws or relevant conditions that exceeded the NMPNS defined or ASME Section Xl acceptance criteria (IWE-3000) or in the case of supports IWF-3000 acceptance criteria; even though the discovery of the flaw or relevant condition that necessitated the repair, replacement or corrective measure, may not have resulted from an examination or test required by Section Xl, and provides such information as Code Class, whether the item is a repair, replacement or corrective action, item description, description of work, if the flaw or relevant condition was found during a scheduled Section Xl Examination or test, date completed and the repair replacement plan number. File: OAR-i1WE17.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-03 l 2 FIRST INSERVICE INSPECTION INTERVAL Rev. 00 Y 44Y ~~~2003 CONTAINMENT INSPECTION I Dv OWNER'S ACTIVITY Date: April 23, 2003 REPORT Paae 1-5 of i -11

d.

Owners' Report for Inaccessible Areas, Table 4, as required by Code of Federal Regulations 10 CFR 50.55a(b)(x), provides such information as a description of the type and estimated extent of degradation, and condition that led to the degradation, description and results of the evaluations, and a description of the corrective actions. Note: If acceptance criteria for a particular item is not specified in Section XI, the provisions of IWA-3100(b) may be used to determine which repairs, replacements, and corrective measures are required to be included in the abstract. Although specifically not addressed in the ASME Code Case, NMPNS approximate submittal date will be ninety (90) days following the end of the each specific inspection period. File: OAR-1IWE17.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-03 I FIRST INSERVICE INSPECTION INTERVAL Rev. 00 SI 'x l2003 CONTAINMENT INSPECTION _It zl OWNER'S ACTIVITY Date: April 23, 2003 REPORT Paae i-6 of i-11 FORM OAR-1 OWNER'S ACTIVITY REPORT As required by the provisions of the ASME Code Case N-532 Report Number NIVIPI -lWI:-nAR-nn.,;-nq Owner Nine Mile Point Nuclear Station. P.O. Box 63. Lake Road. Lycoming. New York 13093 (Name and Address of Owner) Plant Nine Mile Point Nuclear Station, P. 0. Box 63. Lycomina. New York 13093 (Name and Address of Plant) Plant Unit 1 Commercial Service Date December 26.1969 Refueling Outage Number RFO-17 Current Inspection Interval First Inservice inspection interval - December 26,1999 to December 25. 2009 (1st, 2nd, 3rd, 4th, Other) Current Inspection Period Second Inservice Insgection Period - December 25. 2002 to December 26. 2006 (1 St, 2nd, 3rd) ' Edition and Addenda of Section XI applicable tothe Inspection Plan 1998 Edition. No Addenda Date and Revision of Inspection Plan NMP1-IWE-003. Revision 2. Dated March 17.2002 Edition and Addenda of ASME Section Xl applicable to Repairs and Replacements, if different than the Inspection Plan N/A CERTIFICATE OF CONFORMANCE I certify that the statements made in this Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations and corrective measures represented by this report conform to the requirements of Section XI. Certificate of Authorization No. Signed Dt/ N/A Expiration Date N/A .(If applicable) Date 2;Z' -Sh 3 (Principal Engineer - ASME Programs Group) CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York and employed by Factory Mutual Insurance Company of Johnston, Rhode Island have inspected the items described in this Owner's Activity Report, during the period March 14. 2003 to April 23. 2003 and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations and corrective measures described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions NB 8496 Inspector's Signature National Board, State, Province, and Endorsements Date 4( zs 20C'3 File: OAR-11WE17.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-03 FIRST INSERVICE INSPECTION INTERVAL Rev.- 00 IS92~I t 2003 CONTAINMENT INSPECTION _ CJOWNER'S ACTIYITY fDate: April 23, 2003 l ____________REPORT Page 1-7 of i-1i TABLE 1 ABSTRACT OF EXAMINATION AND TESTS As required by the provisions of the ASME Code Case N-532 TOTAL TOTAL TOTAL TOTAL EXAMINATIONS CODE EXAMINATIONS EXAMINATIONS EXAMINATIONS CREDITED (%) EXAMINATIO REQUIRED FOR REQUIRED FOR THIS CREDITED (%) FOR TO REMARKS N INTERVAL PERIOD THE DATE FOR THEEM CATEGORY PERIOD INTERVAL E-A 2322 695 675-97.1% 67.7% E-C 0 0 0% 0% F-A 10 6 6-100% 80% ASME CODE CASE N-491-1 File: OAR-lIWE17.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-03 .7~7] FIRST INSERVICE INSPECTION INTERVAL Rev. 00 2003 CONTAINMENT INSPECTION I t JOWNER'S ACTIVITY Date: April 23, 2003 H REPORT Paae 1-8 of i-11 TABLE 2 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRE EVALUATION FOR CONTINUED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT FLAW CONDITION EXAMINATION ITEM ITEM CHARACTERIZATION FOUND DURING CATEGORY NUMBER DESCRIPTION (IWA-3300) SCHEDULED SECTION Xi EXAMINATION OR T E ST (Y E S O R N O ) E-A E1.11 Drywell Interior Surface Liner Plate Major corrosion (rust) Yes E-A E1.11 Drywell Head Access Manway Bolts Damaged threads Yes E-A E1.11 Drywell Head Swing Bolts Damaged bolts No E-A E1.11 Penetration XS-31 1 Access Manway (2) Gouges Yes File: OAR-1IWE17.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-03 FIRST INSERVICE INSPECTION INTERVAL Rev. 00 2003 CONTAINMENT INSPECTION I 5 J OWNER'S ACTIVITY Date: April 23, 2003 REPORT I Pane i-9 of i-11 TABLE 3 ABSTRACT OF REPAIRS, REPLACEMENTS OR CORRECTIVE MEASURES REQUIRED FOR CONTINU'ED SERVICE As required by the provisions of the ASME Code Case N-532 FLAW OR RELEVANT CONDITION FOUND REPAIR DURING SCHEDULED REPAIR REPLACEMENT DESCRIPTION SECTION Xi REPLACEMENT CODE OR CORRECTIVE ITEM OF EXAMINATION OR TEST DATE PLAU CLASS MEASURE DESCRIPTION WORK (YES OR NO) COMPLETE NUMBER MC Replacement Drywell Head Replace studs Yes 03/21/03 WO 01-05708-01 Access and nuts Manway Bolts MC Replacement Drywell Head Replace bolts, No 03/21/03 WO 01-05708-01 Swing Bolts nuts and w ashers ____1 I

4.

9 4 I 4* 4 .4 9 .4 1 .4 1

4.

9 4 I 4 4 File: OAR-iIWE17.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-03 200CNTANMNTNSECTONFIRST INSERVICE INSPECTION INTERVAL Rev. 00 S i) ~~~2003 CONTAINMENT INSPECTION t J OWNER'S ACTIVITY Date: April 23, 2003 I ______________jREPORT Page i-10 of i-11 TABLE 4 OWNER'S DATA REPORT FOR INACCESSIBLE AREAS As required by the provisions of the Code of Federal Regulations 10 CFR 50.55a(b)(x)

1.

Owner: Nine Mile Point Nuclear Station. LLC. P.O. Box 63. Lake Road. Lycoming. New York 13093 (Name and Address of Owner)

2.

Plant: Nine Mile Point Nuclear Station. P.O. Box 63. Lycoming. New York 13093 (Name and Address of Plant) Plant Unit: 1 Commercial Service Date: December 26. 1969

3.

Applicable ASME Section Xl Code 1998 Edition, and NO Addenda For Class MC applications, NMPNS shall evaluate the acceptability of inaccessible areas when conditions exist in accessible areas that could indicate the presence of or result in degradation to such inaccessible areas. For each inaccessible area identified, NMPNS shall provide the following:

4.

Description of the type and estimated extent of degradation, and the conditions that led to the degradation; During scheduled General (G-VT) visual inservice examination (VT-3) of the drywell interior surface of the liner plate, at the 225 foot elevation, major corrosion (rust) was identified near and underneath the area coolers. The corrosion was observed over the entire 360 degree circumference of the liner plate, with varying degrees of oxidation (light, medium and course rust).

5.

An evaluation of each area, and the results of the evaluation; Detailed (D-VT) Visual examination (VT-1), was performed and found no unacceptable degradation in the visible areas of the dry well liner. Evaluation of the inaccessible areas (backside) of the drywell interior surface of the liner plate was performed using ultrasonic thickness measurements to determine any areas of degradation. All thickness measurements were determined to be in excess of material design thickness.

6.

Description of necessary corrective actions; No immediate corrective action was required, other than the steps taken above. File: OAR-1IWE17.WPD

Nine Mile Point Nuclear Power Station Unit 1 NMP1-IWE-OAR-003-03 .7~~7] I FIRST INSERVICE INSPECTION INTERVAL Rev. 00 2003 CONTAINMENT INSPECTION < OWNER'S ACTIVITY Date: April 23, 2003 REPORT Paoe i-11 of i-11 End of Continment Inservice Inspection Owner's Activity Report For Refueling Outage Seventeen (RFO-17) FHe: OAR-IIWE17.WPD}}