Suppression Pool Water Level 3.6.2.2 3.6 CONTAINMENT SYSTEMS 3.6.2.2 Suppression Pool Water Level LCO 3.6.2.2 Suppression pool water level shall be:

a. 18 ft 11 inches and 19 ft 5 inches,
b. 18 ft 11 inches and 20 ft 1 inches, in MODE 3 with reactor pressure less than 235 psig APPLICABILITY: MODES 1, 2, and MODE 3.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Suppression pool water A.1 Restore suppression 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> level not within pool water level to limits. within limits.

OR B. Required Action and B.1 Be in MODE 3. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion Time not met. AND B.2 Be in MODE 4. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.6.2.2.1 Verify suppression pool water level is 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> within limits.

CLINTON 3 .6-31 Amendment No. 156

SPMU System 3.6.2.4 3.6 CONTAINMENT SYSTEMS 3.6.2.4 Suppression Pool Makeup (SPMU) System LCO 3.6.2.4 Two SPMU subsystems shall be OPERABLE.

APPLICABILITY: MODES 1, 2, and 3.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Combined upper A.1 Restore upper 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> containment pool and containment pool and suppression pool water suppression pool levels not within water levels to limit. within limit.

B. Upper containment pool B.l Restore upper 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> water temperature not containment pool water within limit. temperature to within limit.

C. One SPMU subsystem C.1 Restore SPMU 7 days inoperable for reasons subsystem to OPERABLE other than Condition A status.

or B.

D. Required Action and D.1 Be in MODE 3. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion Time not met. AND D.2 Be in MODE 4. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> CLINTON 3. 6-34 Amendment No. 156

SPMU System 3.6.2.4 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.6.2.4.1 Verify upper containment pool water level iS:

a. 2el. 825 ft 6 inches;
b. el. 825 ft 10 inches when the inclined fuel transfer pool to steam dryer storage pool gate is not open; and 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />
c. el. 827 ft 1 inch when the reactor cavity to steam dryer storage pool gate is not open.

OR

d. Reactor cavity pool level l. 824 ft 7 inches in MODE 3 with reactor pressure less than 235 psig.

OR

e. Suppression pool water level 19 ft 9 inches in MODE 3 with reactor pressure less than 235 psig.

SR 3.6.2.4.2 Verify upper containment pool water 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> temperature is 120 0F.

SR 3.6.2.4.3 Verify each SPMU subsystem manual, power 31 days operated, and automatic valve that is not locked, sealed, or otherwise secured in position is in the correct position.

SR 3.6.2.4.4 ------------------ NOTE------------------- 18 months Actual makeup to the suppression pool may be excluded.

Verify each SPMU subsystem automatic valve actuates to the correct position on an actual or simulated automatic initiation signal.

CLINTON 3 .6-35 Amendment No. 156