ML022820028

From kanterella
Jump to navigation Jump to search

Fuel Support Side Entry Orifice Loss Coefficient in Core Monitoring System Databank
ML022820028
Person / Time
Site: Perry, Clinton  
Issue date: 10/04/2002
From: Post J
General Electric Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
02-08NRC.DOC, MFN 02-067
Download: ML022820028 (4)


Text

GE Nuclear Energy General Electric Company 175 Curtner Ave, San Jose, CA 95125 October 4, 2002 02-08NRC.DOC MFN 02-067 Document Control Desk United States Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738

Subject:

Fuel Support Side Entry Orifice Loss Coefficient in Core Monitoring System Databank This letter provides notification of a Reportable Condition under 10CFR 21.21 (d) for Clinton and Perry 1. The basis for this conclusion is the data used for the fuel support side entry orifice (SEO) loss coefficient in the core monitoring system supplied by GE Nuclear Energy (GE)/Global Nuclear Fuel (GNF). Other plants that have a similar geometry, but for which GE/GNF did not provide the core monitoring system (Grand Gulf and River Bend) have also been informed of this issue.

The core support structure in a BWR/6 affects the fuel support casting SEO loss coefficient. Bundles may be adjacent to zero, one, or two core support beams depending upon their location as illustrated in Figure 1. The SEO loss coefficient depends upon the number of adjacent core support beams.

The core monitoring system in the affected plants uses an average SEO loss coefficient for all of the central bundles, and a separate average value for all of the peripheral bundles. This was previously evaluated for GE/GNF 8x8 fuel designs and found to be acceptable. Recent calculations have shown that the Critical Power Ratio (CPR) response for newer GE/GNF fuel designs are more sensitive to the reduced flow in bundles that are adjacent to two core support beams (which have the highest loss coefficient). Thus, the core monitoring system over predicts CPR for these bundles, and thereby, may under predict the margin to the Operating Limit Minimum CPR (OLMCPR). The CPR over prediction is approximately 0.01 in CPR, which reaches the threshold for a reportable condition on a Technical Specification Safety Limit. In actual practice, plants maintain significantly more than 0.01 CPR margin to the OLMCPR, so MCPR Safety Limit protection is not threatened.

October 4, 2002 02-08NRC.DOC MFN 02-067 Figure 1. Sketch of Core Configuration R

Adjacent support beams 2

Lio Core support structure If you have any questions, please call me at (408) 925-5362.

Sincerely, Jason. S. Post, Manager Engineering Quality and Safety Evaluations cc: S. D. Alexander (NRC-NRRIDISP/PSIB) Mail Stop 6 F2 C. V. Hodge (NRC-NRR/DISP/PSIB) Mail Stop 12 H2 J. F. Klapproth (GE-NE)

H. J. Neems (GE-NE)

PRC File

Attachment:

1. Reportable Condition Evaluation per §21.21(d) 2 n

VM

/4-/-

October 4, 2002 02-08NRC.DOC MFN 02-067 -Reportable Condition per §21.21(d)

(i)

Name and address of the individual informing the Commission:

Jason S. Post, Manager, Engineering Quality & Safety Evaluation, GE Nuclear Energy, 175 Curtner Avenue, San Jose, CA 95125 (ii)

Identification of the facility, the activity, or the basic component supplied for such facility or such activity within the United States which fails to comply or contains a defect:

The basic component is the databank for the GE/GNF supplied core monitoring system for monitoring of minimum critical power ratio (MCPR) for BWR/6 plants that use 9x9 and lOxl0 GE/GNF fuel designs.

(iii)

Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect:

GE Nuclear Energy, San Jose, California, and Global Nuclear Fuel, Wilmington, North Carolina (iv)

Nature of the defect or failure to comply and safety hazard which is created or could be created by such defect or failure to comply:

The SEO is the primary flow path for core flow to enter a fuel bundle. Due to the core inlet geometry in a BWR/6, the flow path to the SEO is more tortuous for a bundle that is adjacent to two core support beams. The bundles adjacent to two core support beams will have a loss coefficient that is about 20% higher than a bundle adjacent to one core support beam, and about 40% higher than a bundle that is not adjacent to any core support beams. This configuration does not exist on BWR/2-5 plants.

Bundle flow has a significant impact on CPR and power of a bundle. As bundle flow drops, the CPR decreases (i.e., the margin to boiling transition is reduced).

However, this also leads to an increased void fraction in the bundle, which reduces bundle power and tends to increase CPR. For earlier GE/GNF fuel designs, these were offsetting effects and using an average SEO loss coefficient for every bundle in the core monitoring system was acceptable. For newer GE/GNF fuel designs, the CPR decrease from a flow reduction is greater than the CPR increase from the corresponding power reduction. Thus, using an average SEO loss coefficient for a bundle adjacent to two core support beams over predicts the CPR for that bundle.

If that is a limiting bundle for CPR, then the margin to the OLMCPR is over predicted.

10CFR21.4 specifies that a condition is reportable if it can produce a significant safety hazard or lead to violation of a Technical Specification Safety Limit. A CPR impact of 0.01 has been used as the threshold of reporting a SLMCPR impact 3

October 4, 2002 02-08NRC.DOC MFN 02-067 under 10CFR21.21(d).

This condition does not produce a significant safety hazard, but the calculated impact on CPR is approximately 0.01, which leads to the conclusion that it represents a Reportable Condition.

(v)

The date on which the information of such defect or failure to comply was obtained:

August 8, 2002 (vi)

In the case of a basic component which contains a defect or failure to comply, the number and locations of all such components in use at, supplied for, or being supplied for one or more facilities or activities subject to the regulations in this part:

A defect has been confirmed to exist in the databank for the GE/GNF supplied core monitoring systems at Clinton and Perry 1.

(vii)

The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action (note, these are actions specifically associated with the identified Reportable Condition):

The affected plants have been notified.

GE/GNF is developing a modification to the core monitoring system databank so that it will assign a location specific SEO loss coefficient to each bundle in the core. The databank modification will be completed within a few days of the date of this notice.

(viii)

Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees:

GE/GNF recommends that the affected plants immediately implement a 0.01 administrative penalty on the OLMCPR until the core monitoring system databank can be modified to use an accurate value of SEO loss coefficient for each bundle.

GE/GNF recommends that the updated core monitoring system databank be implemented as soon as it is available, at which time it is no longer necessary to use an administrative penalty on the OLMCPR.

4