Site: Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Nine Mile Point, Palisades, Indian Point, Kewaunee, Saint Lucie, Point Beach, Oyster Creek, Cooper, Pilgrim, Arkansas Nuclear, Prairie Island, Brunswick, Surry, Turkey Point, Vermont Yankee, Crystal River, Haddam Neck, Ginna, U.S. Geological Survey, Duane Arnold, Farley, Robinson, San Onofre, Cook, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Fort Calhoun, FitzPatrick, 05000000, Trojan, Crane
Issue date: 09/27/1979
From: Eisenhut D
Office of Nuclear Reactor Regulation
To:
References
NUDOCS 7910220413, GL-79-046
Download: ML031320191 (4)


bc)Q

UNITED STATES

NUCLEAR REGULATORY COMMISSION l

0.

Z WASHINGTON, D. C. 20555 GL<- 7 /-

September 27, 1979 ALL LIGHT WATER REACTORS 2'

Gentlemen:

RE: Containment Purging and Venting During Normal Operation - Guidelines For Valve Operability By letter dated November 28, 1978, the Commission (NRC) requested all licensees of operating reactors to respond to generic concerns about containment purging and venting during normal plant operation. We are continuing our review of responses to those letters.

As a result of our reviews, we have learned from several licensees that at least three valve vendors have reported that their valves may not close against the ascending differential pressure and the resulting dynamic loading of the design basis LOCA. All identified licensees who are affected.

have proposed to maintain the valves in the closed position or to restrict the angular opening of the valves whenever primary containment integrity is required pending a re-evaluation which shows satisfactory valve performance under the Design Basis Accident - Loss of Coolant Accident (DBA-LOCA)

condition can be provided.

We have developed the enclosed guidelines with the aid of our consultants, Brookhaven National Laboratory. Valve manufacturers have also been contacted and are cognizant of these guidelines. You are requested to initiate action on an expedited basis to ensure that containment vent and purge valves at your facility meet these guidelines.

Please inform us within 30 days that you commit to implement a valve qualification program on an expedited basis.

S cerely,

-

~i ut"

Division of O rating Reactors Enclosure: M

Guidelines for Demonstration of Operability of Purge and Vent Valves cc: w/enclosure See next page e

ENCLOSURE

GUIDELINES FOR DEMONSTRATION

OF OPERABILITY OF PURGE AND

VENT VALVES

OPERABILITY

In order to establish operability it must be shown that the valve actuator's torque capability has sufficient margin to overcome or .resist the torques and/or forces (i.e., fluid dynamic, bearing, seating, friction) that resist closure when stroking from the initial open position to full seated (bubble tight)

in the time limit specified. This should be predicted on the pressureIs)

established in the containment following a design basis LOCA. Considerations which should be addressed in assuring valve design adequacy include:

1. Valve closure rate versus time - i.e., constant rate or other.

2. Flow direction through valve; .4P across valve.

3. Single valve closure (inside containment or outside containment valve)

or simultaneous closure. Establish worst case.

4. Containment back pressure effect on closing torque margins of air operated valve which vent pilot air inside containment.

5. Adequacy of accumulator (when used) sjzing and initial charge for valve closure requirements.

6. For valve operators using torque limiting devices - are the settings of the devices compatible with the torques required to operate the valve during the design basis condition.

7. The effect of the piping system (turns, branches) upstream and downstream of all valve instillations.

8. The effect of butterfly valve disc and shaft orientation to the fluid mixture egressing from the containment.

DEMONSTRATION

Demonstration of the various aspects of operability of purge and vent valves may be by analysis, bench testing, insitu testing or a combination of these means.

Purge and vent valve structural elements (valve/actuator assembly) must be evaluated to have sufficient stress margins to withstand loads imposed while valve closes during a design basis accident. Torsional shear, shear, bending, tension and compression loads/stresses should be considered. Seismic loading should be addressed.

Once valve closure and structural integrity are assured by analysis, testing or a suitable combination, a determination of the sealing integrity after closure and long term exposure to the containment environment should be evaluated. Emphasis should be directed at the effect of radiation and of the containment spray chemical solutions on seal material. Other aspects such as the effect on sealing from outside ambient temperatures and debris should be considered.

_ - A_

-2- The following considerations apply when testing is chosen as a means for demonstrating valve operability:

Bench Testing A. Bench testing can be used to demonstrate suitability of the in-service valve by reason of its tracibility .indesign to a test valve. The following factors should be considered when qualifying valves through bench testing.

1. Whether a valve was qualified by testing of an identical valve assembly or by extrapolation of data from a similarly designed valve.

2. Whether measures were taken to assure that pi.ing upstream and down- stream and valve orientation are simulated.

3. Whether the following load and environmental factors were considered a. Simulation of LOCA

b. Seismic loading c. Temperature soak d. Radiation exposure e. Chemical exposure d. Debris B. Bench testing of installed valves to demonstrate the suitability of the specific valve to perform its required function'during the postulated design basis accident is acceptable.

1. The factors listed in items A.2 and A.3 should be considered when taking this approach.

In-Situ Testing In-situ testing of purge and vent valves may be performed to confirm.the suitability of the valve under actual conditions. When performing such tests, the conditions (loading, environment) to which the valve(s) will be subjected during the test should simulate the design basis accident.

NOTE: Post test valve examination should be performed to establish structural integrity of the key valve/actuator components.

-Ao~-:.

\J

Mr. William J. Cahill, Jr. 50-3 Consolidated Edison Company of New York, Inc. 50-274 cc: White Plains Public Library

100 Martine Avenue White Plains, New York 10601 Joseph D. Block, Esquire Executive Vice President Administrative Consolidated Edison Company of New York, Inc.

4 Irving Place

  • New York, New York 10003 Edward J. Sack, Esquire Law Department Consolidated Edison Company of New York, Inc.

4 Irving Place New York, New York 10003 Anthony Z. Roisman Natural Resources Defense Council

917 15th Street, N.W.

Washington, D. C. 20005 Dr. Lawrence R. Quarles Apartment .51 Kendal at Longwood Kennett Square, Pennsylvania 19348 Theodore A. Rebelowski U. S. Nuclear Regulatory Commission P. 0. Box 38 Buchanan, New York 10511

Template:GL-Nav