Duke R.
A.
JONES
- arPower, Vice President A Duke Energy Company Duke Power 29672 / Oconee Nuclear Site April 24, 2003 7800 Rochester Highway Seneca, SC 29672 864 885 3158 864 885 3564 fax U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.
20555
Subject:
Oconee Nuclear Site Docket Nos. 50-269, 50-270 and 50-287 Revision to the 2001 Annual Effluent Release Report Gentlemen:
Attached are revised pages for the 2001 Oconee Annual Effluent Release Report.
The revision is due to incorrect data entry of tritium concentration values for the Unit Vent, 3RIA53, and 4RIA45 monthly effluent calculations.
The data entry corrections resulted in an additional 12.1 curies of airborne tritium for 2001.
The calculated maximum airborne organ dose increased to 3.83E-02 mrem from 3.52E-02 mrem representing less than 0.1 percent of the 45 mrem annual Selected Licensee Commitments maximum airborne organ dose limit.
Should there be questions concerning this report please contact Judy E. Smith at (864) 885-4309.
Very truly yours, 34 kU{9 t~4 R. A. Jones Site Vice President Oconee Nuclear Site Attachments www duke-energy corn
U. S. Nuclear Regulatory Commission April 24, 2003 Page 2 Xc:
Mr. L. A. Reyes Regional Administrator, Region II Mr. L. N. Olshan Project Manager, ONRR Mr. Mel Shannon Senior Resident Inspector, ONS Mr. Henry Porter Division of Radioactive Waste Management American Nuclear Insurers ANI Library Town Center, Suite 300S 29 South Main Street West Hartford, CT 06107-2445 Mr. William Nestel INPO Records Center 700 Galleria Place, Suite 100 Atlanta, GA 30339-5957
TABLE 1A EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS EFFLUENTS -
SUMMATION OF ALL RELEASES Oconee Nuclear Station Units 1, 2, & 3 REPORT FOR 2001 Unit QTR 1 QTR 2 QTR 3 QTR 4 YEAR A. Fission and Activation
- 1. Total Release
- 2. Avg. Release Rate B. Iodine-131
- 1. Total Release
- 2. Avg. Release Rate C. Particulates Half Life
- 1. Total Release
- 2. Avg. Release Rate D. Tritium
- 1. Total Release
- 2. Avg. Release Rate Gases Ci 5.40E+00 pCi/sec 6.95E-01 4.02E+00 1.79E-01 2.49E+00 1.21E+01 5.11E-01 2.25E-02 3.13E-01 3.83E-01 Ci 1.15E-05 6.08E-04 pCi/sec 1.48E-06 7.73E-05 0.OOE+00 2.10E-05 6.40E-04 O.OOE+00 2.65E-06 2.03E-05
>= 8 days Ci 0.OOE+00 pCi/sec 0.OOE+00 Ci 3.OOE+01 pCi/sec 3.86E+00 2.38E-06 4.83E-06 5.53E-07 7.76E-06 3.03E-07 6.07E-07 6.96E-08 2.46E-07 1.76E+01 2.34E+01 1.42E+01 2.24E+00 2.95E+00 1.78E+00 8.53E+01 2.70E+00
TABLE 1B EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS EFFLUENTS -
ELEVATED RELEASES -
CONTINUOUS MODE Oconee Nuclear Station Units 1, 2, & 3 REPORT FOR 2001
- 1. Fission and Activation XE-133 XE-135 Totals for Period...
- 2. lodines I-131 1-133 Totals for Period...
Unit QTR 1 QTR 2 QTR 3 QTR 4 Gases Ci 8.72E-02 Ci 0.OOE+00 Ci 8.72E-02 Ci 1.14E-05 Ci 1.15E-05 Ci 2.29E-05 0.OOE+00 0.OOE+00 0.OOE+00 5.98E-04 7.77E-05 6.76E-04 2.25E-06 2.25E-06 0.OOE+00
- 6. 84E-02 6.84E-02 0.OOE+00 2.42E-05 2.42E-05 2.65E-06 2.65E-06 0.OOE+00 0.0OE+00 0.OOE+00 1.87E-05 1.06E-05 2.93E-05 0.0OE+00 0.0OE+00 YEAR 8.72E-02 6.84E-02 1.56E-01 6.28E-04 1.24E-04 7.52E-04 4.91E-06 4.91E-06
- 3. Particulates Half Life >= 8 days CS-137 Ci 0.0OE+00 Ci 0.OOE+00 Totals for Period...
- 4. Tritium H-3 Ci 2.63E+01 1.63E+01 2.21E+01 1.35E+01 7.81E+01 Ci 2.63E+01 1.63E+01 2.21E+01 1.35E+01 7.81E+01 Totals for Period...
TABLE IC EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS EFFLUENTS -
GROUND RELEASES -
CONTINUOUS MODE Oconee Nuclear Station Units 1, 2, & 3 REPORT FOR 2001 Unit QTR 1 QTR 2 QTR 3 QTR 4 YEAR
- 1. Fission and Activation XE-133 Totals for Period...
- 2. lodines 1-131 1-133 Totals for Period...
Gases Ci 0.OOE+00 Ci O.OOE+00 Ci 0.OOE+00 Ci 0.OOE+00 6.43E-01 6.43E-01 6.02E-06
- 0. OOE+00 6.02E-06 0.0 OE+00 1.11E-07 1.1lE-07 O.OOE+00 0.0OE+00 0.OOE+00 0.OOE+00 0.OOE+00 8.80E-07 1.29E-06 2____E__
2.17E-06 0.OOE+00 0.OOE+00 8.91E-07 7.90E-07 1.68E-06 0.OOE+00 0.OOE+00 0.OOE+00 6.43E-01 6.43E-01 6.91E-06 7.90E-07 7.70E-06 8.80E-07 1.40E-06 2.28E-06
- 3. Particulates Half Life >= 8 days CO-58 Ci CS-137 Ci 0.OOE+00 0.OOE+00 0.OOE+00 Totals for Period...
Ci
- 6. 89E+00 6.89E+00 Totals for Period...
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS ANNUAL DOSE
SUMMARY
REPORT Oconee Nuclear Station Units 1, 2, & 3 1St Quarter 2001 IODINE, H3, and PARTICULATE DOSE LIMIT ANALYSIS======= Quarter 1 2001 Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem)
(mrem)
Limit QI - Maximum Organ Dose CHILD THYROID 9.85E-03 2.25E+01 4.38E-02 Maximum Organ Dose Receptor Location: 1.0 Mile SW Critical Pathway: Vegetation Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 9.77E+01 NOBLE GAS DOSE LIMIT ANALYSIS========================= Quarter 1 2001====
Dose Limit
% of Period-Limit (mrad)
(mrad)
Limit Ql - Maximum Gamma Air Dose 1.0SE-04 1.50E+01 7.OOE-04 Maximum Gamma Air Dose Receptor Location:
1.0 Mile SW Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage XE-133 9.05E+01 Ql - Maximum Beta Air Dose 3.14E-04 3.OOE+01 1.05E-03 Maximum Beta Air Dose Receptor Location:
1.0 Mile SW Major Contributors (5% or greater to total)
Nuclide Percentage XE-133 8.99E+01 KR-85 5.14E+00
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS ANNUAL DOSE
SUMMARY
REPORT Oconee Nuclear Station Units 1, 2, & 3 3rd Quarter 2001 IODINE, H3, and PARTICULATE DOSE LIMIT ANALYSIS======= Quarter 3 2001 Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem)
(mrem)
Limit 03 -
Maximum Organ Dose CHILD LIVER 6.97E-03 2.25E+01 3.10E-02 Maximum Organ Dose Receptor Location: 1.0 Mile SW Critical Pathway: Vegetation Major Isotopic Nuclide H-3 Contributors (5% or greater to total)
Percentage 9.92E+01
NOBLE GAS DOSE LIMIT ANALYSIS==
==
====== Quarter 3 2001
Dose Limit
% of Period-Limit (mrad)
(mrad)
Limit Q3 -
Maximum Gamma Air Dose 1.86E-05 1.50E+01 1.24E-04 Maximum Gaymma Air Dose Receptor Location:
1.0 Mile SW Major Isotopic Nuclide AR-41 XE-135 XE-133 Contributors (5% or greater to total)
Percentage 5.09E+01 4.05E+01 8.50E+00 Q3 - Maximum Beta Air Dose 1.77E-05 3.OOE+01 5.90E-05 Maximum Beta Air Dose Receptor Location:
1.0 Mile SW Major Contributors (5% or greater to total)
Nuclide Percentage XE-135 5.43E+01 XE-133 2.65E+01 AR-41 1.88E+01
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS ANNUAL DOSE
SUMMARY
REPORT Oconee Nuclear Station Units 1, 2, & 3 4th Quarter 2001 IODINE, H3, and PARTICULATE DOSE LIMIT ANALYSIS======= Quarter 4 2001
==
Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem)
(mrem)
Limit Q4 -
Maximum Organ Dose CHILD THYROID 4.50E-03 2.25E+01 2.00E-02 Maximum Organ Dose Receptor Location: 1.0 Mile SW Critical Pathway: Vegetation Major Isotopic Nuclide H-3 I-131 Contributors (5% or greater to total)
Percentage 9.04E+01 9.34E+00
-== NOBLE GAS DOSE LIMIT ANALYSIS--======================= Quarter Dose Limit 4 2001
=
% of Period-Limit (mrad)
(mrad)
Limit Q4 -
Maximum Gamma Air Dose 5.20E-05 1.50E+01 3.47E-04 Maximum Gamma Air Dose Receptor Location:
1.0 Mile SW Major Isotopic Nuclide
_-_______3 XE-133 XE-135 Contributors (5% or greater to total)
Percentage 8.55E+01 1.39E+01 Q4 -
Maximum Beta Air Dose 1.45E-04 3.OOE+01 4.83E-04 Maximum Beta Air Dose Receptor Location:
1.0 Mile SW Major Contributors (5% or greater to total)
Nuclide Percentage XE-133 9.10E+01 XE-135 6.38E+00
EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT PERIOD 1/1/01 TO 1/1/02 GASEOUS ANNUAL DOSE
SUMMARY
REPORT Oconee Nuclear Station Units 1, 2, & 3 ANNUAL 2001
-== IODINE, H3, and PARTICULATE DOSE LIMIT ANALYSIS======= Annual 2001=======
Critical Critical Dose Limit Max % of Period-Limit Age Organ (mrem)
(mrem)
Limit Yr - Maximum Organ Dose CHILD THYROID 3.83E-02 4.50E+01 8.51E-02 Maximum Organ Dose Receptor Location: 1.0 Mile SW Critical Pathway: Vegetation Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage H-3 6.77E+01 1-131 3.20E+01 NOBLE GAS DOSE LIMIT ANALYSIS========================= Annual 2001
=
Dose Limit
% of Period-Limit (mrad)
(nrad)
Limit Yr - Maximum Gamma Air Dose 2.75E-04 3.00E+01 9.17E-04 Maximum Gamma Air Dose Receptor Location:
1.0 Mile SW Major Isotopic Contributors (5% or greater to total)
Nuclide Percentage XE-133 8.46E+01 XE-135 7.80E+00 AR-41 6.39E+00 Yr - Maximum Beta Air Dose 7.62E-04 6.OOE+01 1.27E-03 Maximum Beta Air Dose Receptor Location:
1.0 Mile SW Major Contributors (5% or greater to total)
Nuclide Percentage XE-133 9.08E+01
Oconee Nuclear Station 2001 Radioactive Effluent Releases 40CFR190 Uranium Fuel Cycle Dose* Calculation Results Maximum Total Body Dose = 3.82E-01 mrem Maximum Location:
Site Boundary (1.0 mile), South-West Sector Critical Age = Adult Liquid and Gas Effluent Contribution to Maximum Total Body Dose Liquid Effluent Dose = 3.64E-01 mrem = 95% of total Critical Path = Fish Major Contributors = Cs-137 (86.4%)
H-3 (8.0%)
Gas Effluent Dose = 1.78E-02 mrem = 5% of total Critical Path = Vegetable Major Contributor = H-3 (99.6%)
Maximum Organ Dose = 6.32E-01 mrem Maximum Location:
Site Boundary (1.0 mile), South-West Sector Critical Age = Adult Critical Organ = GILLI Liquid and Gas Effluent Contribution to Maximum Organ Dose Liquid Effluent Dose = 6.14E-01 mrem = 97% of total Critical Path = Fish Major Contributors = Nb-95 (88.4%)
Gas Effluent Dose = 1.78E-02 mrem = 3% of total Critical Path = Vegetable Major Contributors = H-3 (99.8%)
Annual dose limits from 40CFRl90.10(a) of 25 mrem whole body, 75 mrem to the thyroid, and 25 mrem to any other organ.