ML031220172

From kanterella
Jump to navigation Jump to search
Annual Radioactive Effluent Release Report - January Through December 2002
ML031220172
Person / Time
Site: Browns Ferry  
(DPR-033, DPR-052, DPR-068)
Issue date: 04/30/2003
From: Abney T
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML031220172 (169)


Text

Tennessee Valley Authority, Post Office Box 2000, Decatur, Alabama 35609-2000 April 30, 2003 10 CFR 50.36a(a) (2) 10 CFR 50, Appendix I,Section IV.B.1 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Mail Stop:

OWFN, P1-35 Washington, D.C. 20555-0001 Gentlemen:

In the Matter of

)

Docket Nos. 50-259 Tennessee Valley Authority

)

50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN) -

UNITS 1, 2, AND 3 -

ANNUAL RADIOACTIVE EFFLUENT RELEASE (ARER) REPORT -

JANUARY THROUGH DECEMBER 2002 In accordance with 10 CFR 50.36a(a)(2); 10 CFR 50, Appendix I,Section IV.B; and the BFN Technical Specification (TS) 5.6.3, TVA is submitting the BFN ARER report for January through December 2002.

Also, in accordance with the BFN Offsite Dose Calculation Manual (ODCM) Section 1.1.1, Action (b), and Section 1.1.2, Action (c), TVA is providing the BFN's Inoperable Radioactive Effluent Instrumentation Report.

However, TVA is not submitting any revision of the ODCM since no ODCM changes were made during this reporting period.

This report includes the following:

Radiological Impact Assessment Report (Enclosure 1)

Meteorological Data Tables (Enclosure 2)

DoY Pnnted on recycled paper

U.S. Nuclear Regulatory Commission Page 2 April 30, 2003 Effluent and Waste Disposal Annual Report (Enclosure 3)

Inoperable Radiological Effluent Instrumentation Report (Enclosure 4)

If you have any questions concerning this submittal, please contact me at (256) 729-2636.

2ncerelY T. E. Abn Manager e sing and dustry Affai s Enclosur cc (w/o Enc es (via NRC Electronic Distribution)

Mr. Stephen J. Cahill, Branch Chief U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth Street S.W., Suite 23T85 Atlanta, Georgia 30303-8931 NRC Resident Inspector Browns Ferry Nuclear Plant 10833 Shaw Road Athens, Alabama 35611-6970 Mr. Kahtan N. Jabbour, Senior Project Manager U.S. Nuclear Regulatory Commission (MS 08G9)

One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852-2739 Mr. Ronald Sanacore (w/Enclosures)

American Nuclear Insurers Town Center, Suite 300S 29 South Main Street West Hartford, Connecticut 06107-2445

ENCLOSURE 1 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 RADIOLOGICAL IMPACT ASSESSMENT REPORT JANUARY THROUGH DECEMBER 2002 TABLE OF CONTENTS I.

Introduction E1-2 II.

Dose Limits El-2 III.

Dose Calculations E1-3 IV.

Doses from Airborne Effluents E1-3 V.

Doses from Liquid Effluents EI-5 VI.

Population Doses E1-5 VII.

Offsite Direct Radiation Dose E1-6 VIII.

Dose to a Member of the Public Inside the Site Boundary E1-6 IX Total Dose El-7 El-l

TABLE OF CONTENTS (Continued)

Listing of Tables Table I - Doses from Airborne Effluents - First Quarter El-8 Table 2 - Doses from Airborne Effluents - Second Quarter El-9 Table 3 - Doses from Airborne Effluents - Third Quarter El-10 Table 4 - Doses from Airborne Effluents - Fourth Quarter El-l1 Table 5 - Doses from Liquid Effluents - First Quarter EI-12 Table 6 - Doses from Liquid Effluents - Second Quarter El-13 Table 7 - Doses from Liquid Effluents - Third Quarter E1-14 Table 8 - Doses from Liquid Effluents - Fourth Quarter EI-15 Table 9 - Total Dose from Fuel Cycle EI-16 Table 10 - Joint Frequency Distribution in Percent for Ground E2 Level Releases - First Quarter E2-9 Table 11 - Joint Frequency Distribution in Percent for Ground E2 Level Releases - Second Quarter E2-17 Table 12 - Joint Frequency Distribution in Percent for Ground E2 Level Releases - Third Quarter E2-25 Table 13 - Joint Frequency Distribution in Percent for Ground E2 Level Releases - Fourth Quarter E2-33 Table 14 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Ground Level Portion) - First Quarter E2-41 Table 15 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Ground Level Portion) - Second Quarter E2-49 Table 16 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Ground Level Portion) - Third Quarter E2-57 Table 17 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Ground Level Portion) - Fourth Quarter E2-65 Table 18 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Elevated Level Portion) - First Quarter E2-73 El-la

TABLE OF CONTENTS (Continued)

Listing of Tables Table 19 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Elevated Level Portion) - Second Quarter E2-81 Table 20 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Elevated Level Portion) - Third Quarter E2-89 Table 21 - Joint Frequency Distribution in Percent for Split Level E2 Releases (Elevated Level Portion) - Fourth Quarter E2-97 Table 22 - Joint Frequency Distribution in Percent for Elevated E2 Releases - First Quarter E2-105 Table 23 - Joint Frequency Distribution in Percent for Elevated E2-106-Releases - Second Quarter E2-113 Table 24 - Joint Frequency Distribution in Percent for Elevated E2-114-Releases - Third Quarter E2-121 Table 25 - Joint Frequency Distribution in Percent for Elevated E2-122-Releases - Fourth Quarter E2-129 El-lb

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 I. INTRODUCTION Potential doses to the "maximum exposed individual" and the population around Browns Ferry are calculated for each quarter as required in Section 5.2 of the Offsite Dose Calculation Manual (ODCM). The methodology for determining plant releases for the reporting period used to estimate dose is specified in Sections 6 and 7 of the ODCM. Dispersion of radioactive effluents in the environment is estimated using meteorological data and river flow measured during the period. In this report, the doses resulting from releases are described and compared to limits established for Browns Ferry.

II. DOSE LIMITS The ODCM specifies limits for the release of radioactive effluents, as well as limits for doses to the general public from the release of radioactive effluents. These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.

The air dose limits in areas at and beyond the Site Boundary due to noble gases released in gaseous effluents per unit are:

< 5 mrad per quarter and

< 10 mrad per year for gamma radiation

- and -

< 10 mmd per quarter and

< 20 mrad per year for beta radiation.

The dose limits to a Member of the Public in an unrestricted area from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives > 8 days released in gaseous effluents for each unit are:

< 7.5 mrem per quarter and

< 15 mrem per year to any organ.

The dose or dose commitment to a Member of the Public from radioactive material in liquid effluents released to unrestricted areas are:

< 1.5 mrem per quarter and

< 3 mrem per year to the total body,

- and -

< 5 mrem per quarter and

< 10 mrem per year to any organ.

The limit for the total effective dose equivalent to an individual Member of the Public inside the site boundary is:

100 mrem per year.

The EPA limits for total dose to any Member of the Public in the vicinity of a nuclear power plant, established in the Environmental Dose Standard of 40 CFR 190, are:

< 25 mrem per year to the whole body,

< 75 mrem per year to the thyroid,

- and -

< 25 mrem per year to any other organ.

El-2

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002

m. DOSE CALCULATIONS Estimated doses to Members of the Public are determined using computer models (the Gaseous Effluent Licensing Code, GELC, and the Quarterly Water Dose Assessment Code, QWATA). These models are based on guidance provided by the NRC (in Regulatory Guides 1.109, 1.111 and 1.113) for determining the potential dose to individuals and populations living in the vicinity of the plant. The area around the plant is analyzed to determine the pathways through which the public may receive a dose The doses calculated are a representation of the dose to a "maximum exposed individual." Some of the factors used in these calculations (such as ingestion rates) are maximum values to ensure conservative reporting data. Many of these factors are obtained from NUREG/CR-1004. The values chosen will tend to overestimate the dose.

The expected dose to actual individuals is lower. The calculated doses are presented in Tables 1, 2, 3, 4, 5, 6, 7, 8, and 9.

IV. DOSES FROM AIRBORNE EFFLUENTS For airborne effluents, Members of the Public can be exposed to radiation from several sources: direct radiation from the radioactivity in the air, direct radiation from radioactivity deposited on the ground, inhalation of airborne radioactivity, ingestion of vegetation which contains radioactivity deposited from the atmosphere, and ingestion of milk and beef which contains radioactivity deposited from the atmosphere onto vegetation and subsequently consumed by milk and beef animals.

Airborne Release Points There are four monitored release points from Browns Ferry Nuclear Plant: the turbine building, the radwaste building, the reactor building, and the stack.

Releases from the turbine building are considered ground-level releases. The ground-level Joint Frequency Distribution (JFD) is derived from windspeeds and directions measured 10 meters above ground and from the vertical temperature difference between 10 and 45 meters, and are presented for each quarter in Tables 10, 11, 12, and 13.

Releases from the radwaste and reactor buildings are considered split-level releases. Portions of the release are treated as ground-level while other portions are considered elevated depending on the ratio of the vertical exit velocity to the horizontal wind speed. The split-level dispersion approach is implemented using a model that requires twvo complete quarterly JFDs for each effluent vent, one for the ground-level releases and one for the elevated releases. The ground-level portion of the split-level JFD is based on wind speeds and directions measured 10 meters above ground-level and from the vertical temperature difference between 10 and 45 meters. The elevated portion of the split-level JFD is based on Nwind speeds and direction measurements at the 45 meter level and the vertical temperature difference between 45 and 91 meters. Both of these JFDs are given for each quarter in Tables 14, 15, 16, 17, 18, 19, 20, and 21.

Releases from the stack are considered to be elevated releases. The JFDs for elevated releases are based on wind directions and wind speeds measured at 91 meters and the vertical temperature difference between 45 and 91 meters, and are given for each quarter in Tables 22, 23, 24, and 25.

El-3

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Meteorolozical Data Meteorological variables at BFN are measured continuously. Measurements collected include wind speed, wind direction, and temperature at heights of 10, 45, and 91 meters above the ground. Quarterly JFDs are calculated for each release point using the appropriate levels of meteorological data. A quarterly JFD gives the percentage of the time that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine wind speed ranges. Calms are distributed by direction in proportion to the distribution of noncalm wind directions less than 1.6 m/s (3.5 mph). Stability classes are determined from the vertical temperature difference between two measurement levels.

The generally open terrain around BFN does not cause any significant effects on the transport and dispersion of gaseous effluents from the plant. Within 30 kilometers of BFN, the terrain is mostly gently rolling hills (30-60 meters). Between 30 and 80 kilometers the hills become larger to the north and south, and mountainous to the east and northeast. The Tennessee River/Wheeler Lake may have a minor effect on transport and dispersion in the immediate vicinity of BFN during periods of winds with a southerly component, overcast skies, and relatively high wind speeds. Also, the lower layer (10-45 meters) stability class tends to be more stable. However, during this infrequent condition, dose estimates will be conservative.

External Exposure Dose Dose calculated for maximum external air dose (gamma-air and beta-air ) are made for points at and beyond the unrestricted area boundary as described in the BFN ODCM. The highest of these doses is then selected.

Submersion Dose External doses to the skin and total body, due to submersion in a cloud of noble gases, are calculated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.

Organ Dose Dose to an organ due to releases of airborne effluents are estimated for the inhalation, ground contamination, and ingestion pathways. The ingestion pathway is further divided into three possible contributing pathways: ingestion of cowv/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor.

For the ingestion dose, however, only those pathways that exist for each receptor are considered in the sum, i.e., milk ingestion doses are included only for locations where milk was consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden was identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contamination, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.

The maximum organ dose, thyroid dose, and total body dose from airborne effluents are presented in Tables 1, 2, 3, and4.

El-4

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 V. DOSES FROM LIQUID EFFLUENTS For liquid effluents, the public can be exposed to radiation from three sources: the ingestion of water from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactive material deposited on the river shoreline sediment (recreation)

The concentration of radionuclides in the Tennessee River are calculated by a computer model which uses measured hydraulic data downstream of BFN. Parameters used to determine the doses are based on guidance given by the NRC (in Regulatory Guides 1.109) for maximum ingestion rates, exposure times, etc.

Wherever possible, parameters used in the dose calculation are site specific. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the BFN ODCM.

Liquid Release Points and River Data Radionuclide concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. When necessary, liquid releases from BFN, located at Tennessee River Mile 294, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-fifth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at the first downstream dam (Wheeler Dam), at Tennessee River Mile 283.0.

Doses are calculated for locations within a 50 mile radius downstream of the plant site. The maximum potential recreation dose is calculated for a location immediately downstream from the plant's release point.

The maximum exposed individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught anywhere between the plant and the first downstream dam. The maximum exposed individual dose from drinking water is assumed to be that calculated at the nearest downstream public water supply [West Morgan - East Lawrence (WMVIEL)].

This could be interpreted as indicating that the maximum exposed individual, as assumed for liquid releases from Browns Ferry, is an individual who obtains all of his drinking water at WMEL, consumes fish caught from the Tennessee River between BFN and Wheeler Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just downstream of the plant's release point. Doses calculated for the maximum exposed individual due to liquid effluents for each quarter in the period are presented in Tables 5, 6, 7, and 8, along with the average river flows past the plant site for the periods.

VI. POPULATION DOSES Population doses due to airborne effluents are calculated for an estimated 627,000 persons living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distribution. Ingestion population doses are calculated assuming that each individual consumed milk, vegetables, and meat produced within the sector in which the individual resides.

Population doses due to liquid effluents are calculated for the entire downstream Tennessee River population. Water ingestion population doses are calculated using actual population figures for downstream public water supplies Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population Recreation population doses are calculated using historical recreational data on the number of shoreline visits at downstream locations.

Population doses calculated for airborne and liquid effluents are presented in Tables 1, 2, 3, 4, 5, 6, 7, and 8.

El-5

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 VII. OFFSITE DIRECT RADIATION DOSE External ganmma radiation levels were measured by thermoluminescent dosimeters (TLDs) deployed around BFN as part of the offsite Radiological Environmental Monitoring Program (REMP). The quarterly gamma radiation levels determined from these TLDs during this reporting period averaged approximately 16.0 inrem/quarter at onsite (at or near the site boundary) stations and approximately 14.3 mrem/quarter at offsite stations or approximately 1.7 mrem/quarter higher onsite than at offsite stations. This difference is consistent with levels measured for pre-operation and construction phases of TVA nuclear plants where the average radiation levels onsite were generally 2-6 nirem/quarter higher than the levels offsite. This may be attributable to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plants, or other undetermined influences. Fluctuations in natural background dose rates and in TLD readings tend to mask any small increments which may be due to plant operations. Thus, there was no identifiable increase in dose rate levels attributable to direct radiation from plant equipment and/or gaseous effluents.

VIII. DOSE TO A MEMBER OF THE PUBLIC INSIDE THE SITE BOUNDARY Pursuant to ODCM section 7.7.5, a review was performed to determine the highest dose to a member of the public in the site boundary. This review assumed that onsite TVA employees engaged in work activities not associated with nuclear power electric generation were considered as members of the public. The dose to a member of the public consists of the sum of dose commitments from effluent releases as well as any direct radiation dose. The effluent dose commitment is negligible compared to the direct radiation dose.

The direct radiation dose was determined from area TLDs located onsite. It consisted of gamma dose from the plume, ground contamination and from equipment sources (i.e., tanks, turbine shine, radioactive material storage areas, etc.). The highest direct radiation dose accounting for background and occupancy was 5.0 mrem during 2002.

The total annual dose commitment to the member of the public for 2002 is 5.0 mrem; the direct radiation dose while in the site boundary. It can be concluded that the dose limit for a member of the public inside the site boundary as specified in 10 CFR 20.1301 was not exceeded.

El-6

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 IX. TOTAL DOSE To determine compliance with 40 CFR 190, annual total dose contributions to the maximum exposed individual from BFN radioactive effluents and all other nearby uranium fuel cycle sources are considered The annual dose to any organ other than thyroid for the maximum exposed individual is conservatively calculated by summing the following doses: the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFER 190 limit for total body or any organ dose (other than thyroid) to determine compliance.

The annual thyroid dose to the maximum exposed individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for thyroid dose to determine compliance.

Total dose from the fuel cycle is presented in Table 9.

El-7

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 1 Doses from Airborne Effluents First Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 5.8E-06 mrad 5 mrad

< 1 %

S/6800 meters Beta Air 9.3E-06 mrad 10 mrad

< 1 %

S/6800 meters Submersion Total Body 2.7E-04 mrem NA NA N/2000 meters Skin 3.2E-04 mrem NA NA N!2000 meters Organ Doses Child/Bone 1.4E-02 mrem 7.5 mrem

< 1 %

NNW/1770 meters Child/Thyroid 4.1E-02 mrem 7.5 mrem

< 1 %

NNW/1770 meters Child/Total Body 1.2E-02 mrem 7.5 mrem

< 1 %

NNW/1770 meters Population Doses Total Body Dose 1.9E-02 man-rem Maximum Organ Dose (organ)

8. JE-02 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

E1-8

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 2 Doses from Airborne Effluents Second Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 1.1E-05 mrad 5 mrad

<1 %

WNW/5500 meters Beta Air 3.0E-05 mrad 10 mrad

<1 %

WNW/5500 meters Submersion Total Body 9.4E-04 mrem NA NA NNW/1639 meters Skin L. l03 mrem NA NA NNW/1639 meters Organ Doses Child/Liver 8.3E-03 mrem 7.5 mrem

< 1 %

NNW/1770 meters Child/Thyroid 2.4E-01 mrem 7.5 mrem 3 %

NNW/1770 meters Child /Total Body 4.6E-03 mrem 7.5 mrem

< 1 %

NNW/1770 meters Population Doses Total Body Dose 1.3E-02 man-rem Maximum Organ Dose (organ) 7.7E-01 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

El-9

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 3 Doses from Airborne Effluents Third Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 9.1E-04 mrad 5 mrad

< 1 %

NNW/5600 meters Beta Air 1.2E-03 mrad 10 mrad

< 1 %

NNW/5600 meters Submersion Total Body 1.6E-03 mrem NA NA NNW/1639 meters Skin 1.9E-03 mrem NA NA NNW/1639 meters Organ Doses Child/Bone 1.6E-02 mrem 7.5 mrem

< 1 %

NNW/1770 meters Child/Thyroid 1.9E-02 mrem 7.5 mrem

< 1 %

NNW/1770 meters Adult/Total Body 6.1E-03 mrem 7.5 mrem

< 1 %

NNW/1770 meters Population Doses Total Body Dose 3.2E-02 man-rem Maximum Organ Dose (organ) 7.9E-02 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-remlyear (based on 90 mrem/yr for natural background).

EI-10

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Tablc 4 Doses from Airborne Effluents Fourth Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 5.3E-04 mrad 5 mrad

<1 %

SSE/7800 meters Beta Air 5.7E-04 mrad 10 mrad

<1 %

SSE/7800 meters Submersion Total Body 2.8E-03 mrem NA NA NNW/1639 meters Skin 3.3E-03 mrem NA NA NNW/1639 meters Organ Doses Child/ Bone 4.4E-02 mrem 7.5 nirem

<1 %

NNW/1770 meters Child/Thyroid 6.5E-01 mrem 7.5 mrem

<1 %

NNW/1770 meters Child /Total Body 2.1E-02 mrem 7.5 nrem

<1 %

NNW/1770 meters Population Doses Total Body Dose 8.2E-02 man-rem Maximum Organ Dose (organ)

2. lE+00 man-rem (thyroid)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

El-ll

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 5 Doses from Liquid Effluents First Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

1.5 mnrem 0 %

Liver Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0 %

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0 %

  • No liquid releases were made this quarter.

Average Riverflow past BFN (cubic feet per second): No Release Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dose for the entire SO-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

El-12

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 6 Doses from Liquid Effluents Second Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

1.5 mrem 0 %

Liver Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0 %

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0 %

  • No liquid releases were made this quarter.

Average Riverflow past BFN (cubic feet per second): No Release Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-ren/year (based on 90 mrem/yr for natural background).

EI-13

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 7 Doses from Liquid Effluents Third Quarter Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

1.5 mrem 0 %

Liver Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0 %

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0 %

  • No liquid releases were made this quarter.

Average Riverflow past BFN (cubic feet per second): No Release Population Doses Total Body Dose 0 man-rem Maxmum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yrfor natural background).

EI-14

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 8 Doses from Liquid Effluents Fourth Quarter Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Total Body Fish Ingestion 0

Recreation 0

Water Ingestion 0

l Total 0

1.5 mrem 0 %

Liver Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mremr 0 %

Thyroid Fish Ingestion 0

Recreation 0

Water Ingestion 0

Total 0

5 mrem 0 %

  • No liquid releases were made this quarter.

Average Riverflow past BFN (cubic feet per second): No Release Population Doses Total Body Dose 0 man-rem Maximum Organ Dose (organ) 0 man-rem (organ)

Population doses can be compared to the natural background dose for the entire SO-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

El-15

Radiological Impact Assessment Browns Ferry Nuclear Plant January - December 2002 Table 9 Total Dose from Fuel Cycle First Second Third Fourth Dose Quarter Quarter Quarter Quarter Total Body or any Organ (except thyroid)

Total body air submersion 2.7E-04 9.4E-04 1.6E-03 2.8E-03 Critical organ dose (air) 1.4E-02 8.3E-03 1.6E-02 4.4E-02 Total body dose (liquid) 0 0

0 0

Maximum organ dose (liquid) 0 0

0 0

Direct Radiation Dose 0

0 0

0 Total 1.4E-02 9.2E-03 1.8E-02 4.7E-02 Cumulative Total Dose (mrem)

(Total body or any other organ) 8.8E-02 Annual Dose Limit (mrem) 2.5E+01 Percent of Limit

< 1 %

Thyroid Dose (mrem)

Total body air submersion 2.7E-04 9.4E-04 1.6E-03 2.8E-03 Thyroid dose (airborne) 4.1E-02 3.4E-01 l.9E-02 6.5E-01 Total bodv dose (liquid) 0 0

0 0

Thyroid dose (liquid) 0 0

0 0

Direct Radiation Dose 0

0 0

0 Total 4.1E-02 3.7E-01 2.1E-02 6.5E-01 Cumulative Total Dose (Thyroid) mrem 9.6E-01 Annual Dose Limit (mrem) 7.5E+01 Percent of Limit

=

1.3 %

E1-16

ENCLOSURE 2 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 METEOROLIGICAL DATA TABLES JANUARY THROUGH DECEMBER 2002 E2-1

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY DECEMBER 2002 TABLE 10 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FIRST QUARTER E2-2

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.047 0.189 0.047 0.047
0. 000 0.000 0.000 0.000 0.473 0.000 0.095 0.000 0.000 0.000 0.000 1.040 0.615 0.709 0.5 67 0.000 0.047 0.095 0.047 0.000 0.000 3.215 0.236 0.095 0.000
0. 000 0.000 0.000 0.473 0.047 0.378 0.095 0.047 0.000 0.142 0.095 0.047 0.189 1.844 0.567 0.331 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.615 0.804 0.757 3.262 0.142 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.047 0.284 0.189 0.615 1.371 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.946 0.615
0. 000 0.000 0.000 0.095 1.560 0.757 1.135 0.851 0.095 0.095 0.378 1.040 1.040 1.560
10. 165 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 215 215 2115 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED =

7.66 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-3

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.189 0.142 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.473
0. 000 0.000 0.000
0. 000 0.047 0.000 0.236 0.142 0.047 0.000 0.000 0.047 0.142 0.047 0.047 0.000 0.757 0.047 0.426 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.000 0.000 0.047 0.000 0.142 0.000 0.000 0.804 0.142 0.095 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.189 0.236 0.189 0.993 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.331 0.189 0.000 0.567 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.189 0.520 0.047 0.000 0.047 0.047 0.331 0.331 0.284 0.000 0.047 0.142 0.236 0.709 0.473 0.189 3.593 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 76 76 2115 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED =

7.89 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-4

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000

0. 000 0.000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.047 0.095 0.095 0.000 0.095
0. 000 0.000 0.000 0.000 0.000 0.331
0. 000
0. 000 0.000 0.000 0.000 0.047 0.284 0.095 0.189 0.095 0.000 0.000 0.047 0.000 0.047 0.047 0.851 0.142 0.331 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.095 0.095 0.000 0.000 0.757 0.000 0.095 0.047
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.047
0. 000 0.047
0. 000 0.142 0.236 0.331 0.946
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.236 0.189 0.095 0.520 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.095 0.000 0.000 0.095
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.142 0.426 0.047 0.000 0.000 0.047 0.378 0.236 0.284 0.142 0.095 0.047 0.142 0.567 0.473
0. 473 3.499 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 74 74 2 115 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED =

8.02 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-5

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBToTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.047 0.000 0.095
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.142 0.142 0.331 0.236 0.331 0.284 0.189 0.520 0.615 0.378 0.331 0.142 0.236 0.142 0.095 0.095 0.095 4.161 0.426 0.709 0.520 0.520 0.236 0.236 0.709 0.5 67 0.189 0.331 0.142 0.095 0.284 0.142 0.236 0.378 5.721 0.662 1.040 0.757 0.189 0.142 0.142 0.189 0.047 0.473 0.000 0.000 0.142 0.520 0.236 0.473 0.709 5.721 2.364 0.757 0.378
0. 000 0.047 0.142 0.284
0. 000 0.142 0.047 0.047 0.142
0. 662 0.804 2.270
2. 128 10.213 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 1.229 1.986 0.473 3.783 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.142 0.142 0.047 0.378 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 3.688 2.837 1.891 1.087 0.709 0.804 1.702 1.229
1. 182 0.709 0.331 0.615
1. 655 2.648 5.201 3.830 0.000 30.118 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 641 637 2115 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED:

2002/05/15 MEAN WIND SPEED =

7.73 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-6

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.095 0.047 0.047

0. 000 0.047 0.000 0.047 0.047 0.426 0.426 0.284 0.142 0.142 0.473 0.993 1.087 0.898 0.851 0.662 0.426 0.520 0.520
0. 000 0.284 0.189 7.896 0.567 0.331 0.615 0.095 0.095 0.284 0.615 1.466 2.175 0.709 0.047 0.095 0.426 0.000 0.426 0.757 8.700 0.426 0.426 0.236 0.142 0.047 0.142 0.236
0. 095 1>182 0.189 0.047
0. 000 0.473 0.236 0.378 0.520 4.775 0.331 0.142 0.047 0.000 0.000 0.000 0.047 0.189 0.709 0.142 0.047 0.047 0.000 0.236 0.520 0.331 2.790 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.047 0.047 0.095 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 1.749
1. 182 1.040 0.378 0.615 1.418 1.986 2.742 5.012 1.749 0.615 0.662 1.466 0.473 1.702 1.891
24. 681 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 525 522 2115 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED =

4.65 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-7

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.004 0.001 0.001 0.003 0.003 0.002 0.010 0.010 0.004 0.002 0.001 0.000 0.001 0.001 0.001 0.003 0.047 0.047

0. 000
0. 000 0.000 0.047 0.047 0.095 0.142 0.189 0.142 0.095 0.047
0. 095 0.000 0.000 0.142 1.087 0.615 0.236 0.236 0.520 0.473 0.378 1.702 1.513 0.473 0.236 0.095 0.000 0.000 0.095 0.142 0.331 7.045 0.567 0.378 0.142 0.095 0.567 0.047 0.567 0.378 1.135 0.331 0.095 0.000 0.000 0.047 0.095 0.898 5.343 0.000 0.095 0.047 0.047
0. 000 0.000 0.047 0.236 0.898 0.236 0.000 0.000 0.000 0.000 0.095 0.095 1.797
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.047 0.993 0.047 0.000 0.000 0.000
0. 000 0.000 0.000 1.087 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.233 0.711 0.427 0.665 1.090 0.475 2.422 2.326
3. 692 0.995 0.285 0.048 0.095 0.142 0.332 1.468 0.000 16.407 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 350 347 2115 1

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED =

3.78 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-8

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.236 0.095
0. 000 0.000 0.000 0.095 0.047 0.662 0.095 0.000 0.000 0.000 0.095 0.047 0.095 0.047 1.513 0.426 0.189 0.047 0.284 0.047 0.047 0.898 3.546 1.087
0. 000 0.047 0.000
0. 000 0.142 0.047 0.615 7.423 0.378 0.142 0.000 0.000 0.000 0.047 0.047 0.804 0.615 0.000 0.000 0.000 0.000 0.000 0.000 0.095
2. 128 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.331 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.473
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 1.040 0.426 0.047 0.284 0.047 0.189 1.040 5.059
2. 128 0.000 0.047 0.000 0.095 0.189 0.142 0.804
11. 537 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2125 244 244 2115 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED =

2.73 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-9

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 11 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES SECOND QUARTER E2-10

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant APR 1,

2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.473 0.757 1.041 0.237 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.473 2.366 0.615 0.899 0.805 0.331 0.331
0. 095 0.047 0.047 0.047 0.142 0.142 0.000 0.047 0.000 0.947 0.426 0.095
0. 000 0.000 0.000 0.000 0.095 0.095 0.142 0.047 1.609 0.663 0.000 0.000 0.000 0.237 0.095 0.000 0.000 0.000 0.000 0.047 0.000 0.331 0.473 0.284 0.047
0. 000 0.047 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000
0. 000 0.047
0. 095 0.142 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.846 0.805 0.047 0.047 0.000
1. 656 3.360 1.467 1.940 1.041 0.379 0.379 0.189 0.521 0.805 0.521 SUBTOTAL 0.000 0.000 2.556 6.105 2.177 3.739 0.379 0.047 0.000 15.002 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 317 317 2113 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =

6.09 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-11

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.237 0.284 0.237 0.379 0.189 0.095
0. 000 0.047
0. 000
0. 000 1.467 0.047 0.047
0. 000
0. 000
0. 000 0.284 0.189 0.047 0.237 0.331 0.331 0.473 0.142 0.000 0.000 0.000
2. 130 0.000 0.095 0.000 0.047 0.000 0.095 0.095 0.000 0.047
0. 000 0.000
0. 000 0.000 0.047 0.095 0.047 0.568 0.189 0.189 0.189 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000 0.047 0.047 0.047 0.189
0. 000 0.899
0. 000 0.047 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.047 0.000 0.095
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.237 0.379 0.189 0.047 0.000 0.379 0.521 0.331 0.521 0.710 0.521 0.615 0.189 0.142 0.331 0.047 5.159 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 110 109 2113 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =

5.22 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-12

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.047 0.142 0.331 0.284 0.284 0.237 0.000 0.047 0.000 0.000 0.000 1.372 0.000
0. 000 0.000 0.095 0.047 0.284 0.142 0.142 0.095 0.189 0.237 0.047 0.095 0.000 0.047 0.047 1.467 0.000 0.095 0.000 0.142 0.000 0.095 0.047 0.000
0. 095 0.000 0.000 0.047 0.047 0.095 0.189 0.000 0.852 0.189 0.047 0.142 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.284 0.095 0.852
0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.095 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.189 0.142 0.142 0.237 0.047 0.473 0.331 0.473 0.473 0.473 0.473 0.095 0.189 0.142 0.615 0.142 4. 638 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 101 98 2113 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =

5.48 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-13

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.047 0.000 0.000 0.000 0.047 0.000 0.237 0.047 0.142 0.047 0.142 0.142 0.473 1.230 0.947 1.514 1.514 0.568 0.615 0.331 0.237 0.142 0.047 8.140 0.237 0.284 0.237 0.237 0.473 1.609 1.325 0.284 0.426 1.088 0.237 0.331 0.331 0.568 0.331 0.331 8.329 0.379 0.426 0.426 0.095 0.142 1.183 0.331 0.047 0.237 0.379 0.000 0.095 0.095 0.237 0.710 0.237 5.017 0.757 0.568 0.142 0.000 0.000

0. 189 0.047 0.000 0.000 0.000 0.000 0.284 0.047 0.284 0.899 0.663 3.881 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.426 0.521 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.047
0. 000 0.000 0.047 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 1.420 1.420 0.852 0.473 0.757 3.455 2.934 1.278 2.224 3.076 0.852 1.325 0.805 1.372 2.224 1.704 0.000 26.171 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 562 553 2113 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =

5.12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-14

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000

0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.047 0.095 0.142 0.095 0.095 0.331 0.095 0.189 0.189 0.095 0.000 0.142 0.095 0.047 0.047 0.000 0.710 0.331 0.805 0.757 1.325 2.035 1.562 0.899 1.183 0.615 0.284 0.284 0.521 0.000 0.142 0.237 0.994 0.473 0.473 0.757 2.035
1. 562 0.379 0.284 0.426 0.805 0.000 0.189 0.331 0.047 0.189 0.142 0.710 0.284 0.615 0.189 0.142 0.379 0.047 0.237 0.142 0.379
0. 000 0.000 0.000 0.047 0.095 0.284 0.331 0.237 0.237 0.000 0.047 0.000 0.000 0.095 0.189 0.047 0.000 0.047 0.000 0.047 0.142 0.095 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.047
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 2.792 1.420 2.272 1.798 3.644 4.307 2.082 1.704
2. 177 1.940 0.284
0. 663 0.947 0.189 0.615 0.757 SUBTOTAL 0.000 1.704 11.690 9.087 3.549 1.514 0.047 0.000 0.000 27.591 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 585 583 2113 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =

3.89 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-15

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 095 0.095 0.237 0.095 0.237 0.142 0.521 0.568 0.189
0. 095 0.142 0.047 0.142 0.095 0.047 0.047 2.792 0.521 0.473 0.805 0.663 1.088 0.852 0.899 0.379 0.379 0.331 0.095 0.095 0.331 0.000 0.047 0.284 7.241 0.379 0.663 0.142 0.189 0.568 0.095 0.095 0.142 0.237 0.000 0.000 0.000 0.047
0. 000 0.142 0.189 2.887 0.095 0.095 0.142 0.095 0.047 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.663
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 1.088 1.325
1. 325 1.041 1.940 1.088 1.514 1.278
0. 805 0.426 0.237 0.142 0.521 0.095 0.237 0.615
13. 677 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 290 289 2113 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =

2.69 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-16

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.331 0.189 0.095 0.237 0.237 0.142 0.284 0.284 0.047

0. 000 0.047 0.000 0.047 0.189 0.095 0.142 2.366 1.183 0.710 0.473 0.568 0.142 0.047 0.047 0.189
0. 189 0.047 0.047 0.000 0.000 0.000 0.142 0.757 4.543 0.331 0.189 0.000 0.095 0.095 0.000 0.000 0.047 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.852 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 1.846 1.088 0.568 0.899 0.473 0.189 0.331 0.521 0.331 0.047 0.095 0.000 0.047 0.189 0.237 0.899 7.761 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2130 165 164 2113 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =

2.07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 7

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 12 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES THIRD QUARTER E2-18

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.185 1.066 0.974 0.278 0.139 0.046
0. 000 0.000 0.000 0.000 2.689
0. 000
0. 000 0.000 0.000 0.000 0.278 1.437 1.762
1. 113 0.788 0.742 0.417 0.000 0.000 0.046 0.000 6.583 0.000 0.000 0.000 0.000 0.046 0.371 0.046 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.556 0.185 0.139
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.046 0.371
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.185 0.139 0.000 0.000 0.046 0.649 1.669 2.828 2.086 1.066
0. 927 0.510
0. 000 0.000 0.046 0.046
10. 199 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 221 220 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

4.16 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-19

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.046 0.046 0.185 0.834 0.510 0.556 0.232 0.046
0. 000
0. 000
0. 000
0. 000
2. 457 0.046 0.000 0.000 0.000 0.093 0.139 0.185 0.278 0.232 0.232 0.464 0.371 0.185 0.046 0.093 0.046 2.411 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.093 0.000 0.046 0.325 0.046 0.371 0.046 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.093 0.000 0.046 0.603 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.093 0.371 0.046
0. 000 0.139 0.278 0.371 1.113 0.742 0.788
0. 695 0.417 0.278 0.232 0.093 0.139 5.795 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 126 125 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

4.20 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-20

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WI ND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.093 0.603 0.325 0.695 0.695 0.417 0.093 0.046 0.046 0.046 0.000 3.106 0.093 0.093 0.093 0.000 0.093 0.232
0. 000
0. 000 0.093 0.139 0.232 0.556 0.185 0.093 0.000 0.000 1.901
0. 000 0.139
0. 000 0.000 0.000 0.046 0.000
0. 000
0. 000 0.000 0.000 0.046 0.139 0.185 0.093 0.093 0.742 0.139 0.232 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.185 0.046 0.649 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.278 0.464 0.093
0. 000 0.093 0.371 0.603
0. 325 0.788 0.834 0.649 0.695 0.417 0.325 0.325 0.139 6.398 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 139 138 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

4.32 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-21

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.046 0.046 0.046 0.139
0. 000 0.093 0.000 0.000
0. 000
0. 000 0.371 0.417 0.371 0.417 0.417 0.510 0.881 1.391 1.205 1.854 2.550 1.484 1.854 0.881 0.278 0.185 0.278 14.975 0.417 0.417 0.510 0.371 0.603 1.808 0.464 0.139 0.185 0.185 0.232 0.695 1.205 0.742 0.510 0.278 8.762 0.695 0.556 0.185 0.325 0.185 0.881 0.185 0.000 0.000 0.046
0. 000 0.046 0.325 0.788 0.556 0.417
5. 192 0.278 0.649 0.325 0.232 0.139 0.139 0.000 0.000 0.046 0.185 0.000 0.000 0.093 0.464 0.695 0.464 3.709 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.808 2.040 1.437 1.344 1.437 3.709 2.086 1.391 2.133 3.106 1.715 2.689 2.503 2.272 1.994
1. 437 0.000 33.102 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 728 714 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

4.36 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-22

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.046 0.185 0.278 0.232 0.185
0. 000 0.139 0.232 0.325 0.185 0.139 0.046 0.046 0.046 0.046 0.139 0.927 0.788 1.020 1.391 1.576 1.947 1.020 0.510 0.927 0.927 0.603 0.649 0.510 0.232 0.325 0.464 0.927 0.788 0.510 0.742 1.576 1.252 0.139 0.000 0.000 0.000
0. 000 0.046 0.371 0.000 0.139 0.417 0.510 0.695 0.649 0.232 0.185 0.139 0.093
0. 000 0.04 6 0.093 0.000 0.000 0.232 0.093 0.000 0.046 0.093 0.371 0.232 0.000 0.139 0.046 0.000 0.046 0.046 0.139 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 2.503 2.828 2.689 2.596 3.662 3.384 1.391 0.788 1.344 1.344 0.742 0.742 1.252 0.371 0.510 1.066 SUBTOTAL 0.000 2.272 13.815 6.908 3.013 1.205 0.000 0.000 0.000 27.214 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 598 587 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

3.49 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-23

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000 0.000 0.000 0.232 0.325 0.000 0.139 0.046 0.093 0.278 0.139 0.000 0.000 0.093 0.000 0.093 0.139 0.000 0.139 1.715 1.159 0.881 0.417 0.881 0.556 0.185 0.093 0.093 0.000 0.000 0.046 0.046 0.093 0.185 0.325 0.417 5.378 1.066 1.252 0.185 0.417 0.603
0. 000 0.000 0.000
0. 000
0. 000 0.046 0.000 0.046 0.046 0.046 0.046 3.755 0.046 0.185 0.046 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.278
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 2.503 2.643 0.649 1.437 1.205 0.278 0.371 0.232 0.000 0.000 0.185 0.046 0.232 0.371 0.371 0.603
11. 127 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 241 240 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

2.89 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-24

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.371 0.371 0.510 0.046 0.046 0.000 0.046 0.000 0.000 0.000 0.093 0.000 0.046 0.000 0.000 0.325 1.854 0.881 0.695 0.556 0.649 0.325 0.093

0. 000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.371 3.616 0.278 0.000 0.046 0.139 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.649 0.000 0.046 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.046
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 1.530 1.113 1.113 0.834 0.417 0.093 0.046 0.000
0. 000 0.046 0.093
0. 000 0.046
0. 000 0.000 0.834 6.166 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2188 135 133 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

2.14 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-25

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 13 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FOURTH QUARTER E2-26

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24. 4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046
0. 000 0.139 0.277 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.462 0.000 0.000 0.000 0.000 0.000 0.092 0.416 0.139 0.4 62 0.185 0.046 0.000 0.000 0.000 0.000 0.000 1.341 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.046 0.046 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000
0. 000 0.000 0.000 0.139 0.416 0.277 0.740 0.185 0.046 0.000 0.000
0. 000 0.092 0.046 2.034 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 44 44 2163 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =

4.86 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-27

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.185 0.185 0.046 0.046 0.000
0. 000 0.000 0.000 0.000 0.555
0. 000 0.000 0.000 0.046 0.046 0.000 0.324 0.046 0.139 0.092 0.092 0.000 0.000 0.000 0.000 0.000 0.786 0.000 0.092
0. 000
0. 000
0. 000 0.046
0. 000 0.000 0.000 0.000 0.000 0.046 0.046
0. 000 0.000 0.092 0.324 0.139 0.000 0.046
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.046 0.046
0. 000 0.046 0.139 0.462 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.046 0.231 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.185 0.092 0.046 0.046 0.046 0.046 0.416 0.231 0.324 0.139 0.139 0.092 0.092 0.046 0.139 0.277 2.358 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 51 51 2163 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =

6.31 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-28

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.185 0.139 0.185 0.000 0.046
0. 000 0.000 0.000 0.000 0.693 0.046
0. 000 0.000 0.000 0.000 0.185 0.046 0.046 0.092 0.185 0.046 0.092 0.000 0.092 0.000 0.092 0.925 0.000 0.000 0.046 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.231
0. 000 0.416 0.185 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.185 0.185 0.370 0.971 0.046
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.046 0.139 0.139 0.046 0.416 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000 0.277
0. 000 0.046 0.000
0. 000 0.185 0.185 0.231 0.231 0.370 0.046 0.231 0.092 0.4 62 0.555 0.509 3.421 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2172 74 74 2163 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =

7.06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-29

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4' CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.046 0.046 0.046 0.092 0.000
0. 000 0.000 0.000 0.092 0.647 0.277 0.4 62 0.740 0.925 0.647 1.526 1.757 1.479 0.647 0.555 0.416 0.4 62 0.185 0.277 0.370 1.341 1.248 1.156 0.370 1.248 1.942 0.555 0.693 0.370 0.092 0.324 0.277 0.555 0.832 1.248 1.110 1.017 1.017 0.462 0.324 0.046 1.526 0.185 0.046 0.046 0.092 0.000 0.231 0.832 0.878 0.509 1.202 0.555 0.693 0.324 0.046 0.092 0.277 0.185 0.046 0.000 0.000 0.000 0.277 0.971 1.248 1.849 3.282 0.000 0.092 0.139 0.046 0.000 0.046 0.000
0. 000 0.000 0.000 0.000 0.000 0.231 1.110 1.063 0.370 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 3.560 3.329 2.589 1.526 2.312 4.438 2.497 2.589 1.942 0.878 0.971 1.202 3.051 4.300 4.993 6.426 SUBTOTAL 0.000 0.416 11.373 13.361 8.414 9.847 3.098 0.092 0.000 46.602 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 1013 1008 2163 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED = 6.05 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-30

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.046 0.092 0.046 0.185 0.046 0.185 0.324 0.139 0.139 0.139 0.000 0.185 0.046 0.092 0.092
0. 139 0.509 0.601 0.370 0.509 0.740 1.063 0.878 1.618 1.711 0.370 0.555 0.509 0.277 0.139 0.324 0.647 0.878 0.370 0.092 0.277 0.370 0.509 0.324 0.647 0.878 0.509 0.092 0.370 0.231 0.092 0.231 0.878 6.750 0.4 62 0.277 0.185 0.046 0.000 0.416 0.324 0.509 0.647 0.092
0. 000 0.370 0.139 0.139 0.185 0.509 4.300 0.185 0.000 0.000 0.092 0.000 0.185 0.231 0.000 0.462 0.231 0.000 0.046 0.046 0.000 0.092 0.324 1.896 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 2.080 1.341 0.693 1.110 1.156 2.358 2.080 2.913 3.837 1.341 0.647 1.479 0.740 0.4 62 1.017 2.543 25.798 1.896 10.818 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 561 558 2163 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =

4.01 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-31

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.185 0.092 0.000 0.092 0.092 0.277 0.231 0.046 0.092 0.046 0.139

0. 000 0.046 0.000 0.046 1.433 1.063 0.416 0.277 0.231 0.740 0.555 0.740 1.341 0.786 0.324 0.185 0.092 0.092 0.046 0.092 0.601 7.582 0.971 0.277 0.000 0.046 0.231 0.000 0.324 0.370 0.416 0.000 0.000 0.000 0.000 0.000 0.000 0.416 3.051 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.231
0. 000 0.000 0.000
0. 000 0.000 0.046 0.046 0.462 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.277 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 2.080 0.878 0.370 0.277 1.063 0.647 1.433 2.034 1.618 0.416 0.231 0.231 0.092 0.092 0.139 1.202 12.806 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 278 277 2163 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =

2.90 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-32

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.509 0.416 0.139 0.046 0.092 0.231
0. 092
0. 185 0.185
0. 000
0. 000
0. 000 0.046 0.046 0.092 0.092
2. 173 1.063 0.416 0.462 0.509 0.092 0.139 0.139 1.063 0.139 0.000 0.000 0.000 0.046 0.000 0.046 0.277
4. 392 0.277 0.000 0.000
0. 000 0.000 0.000
0. 000 0.092
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.370 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 1.849 0.832 0.601 0.555 0.185 0.370 0.231 1.341 0.370 0.000 0.000 0.000 0.092 0.046 0.139 0.370 6.981 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2172 151 151 2163 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =

2.03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-33

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 14 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

FIRST QUARTER E2-34

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 009 0.000
0. 000
0. 000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.059 0.033 0.070 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.209 0.019 0.010 0.000 0.000 0.000 0.000 0.070 0.008 0.072 0.018 0.007 0.000 0.015 0.004 0.002 0.014 0.240 0.078 0.051 0.000 0.000 0.000 0.017 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.087 0.122 0.117 0.490 0.034 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.054 0.037 0.124 0.279
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.130 0.080 0.000 0.000 0.000 0.017 0.129 0.041 0.142 0.075 0.007 0.000 0.043 0.145 0.162 0.255 1.227 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2108.000 310. 980 25.860 25.860 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-35

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.003 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 011 0.006
0. 000
0. 000
0. 000 0.002 0.000 0.000 0.000 0.000 0.019 0.006 0.040
0. 000
0. 000 0.000
0. 009 0.009
0. 000 0.009 0.000 0.000 0.007 0.000 0.009 0.000 0.000 0.087 0.022 0.011 0.007 0.000 0.000 0.000 0.000 0.000 0.016 0.000 0.000 0.000 0.009 0.027 0.037 0.031 0.160 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 009 0.096 0.043
0. 000 0.148 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.028 0.051 0.007 0.000 0.000 0.009 0.022 0.007 0.025
0. 000
0. 000 0.009 0.018 0.131 0.080 0.031 0.418 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2 108.000 310. 980 8.810 8.810 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-36

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24. 5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.009 0.000 0.010 0.010 0.000 0.000 0.000 0.000 0.000 0.001 0.035 0.017 0.027 0.000
0. 000 0.000 0.000 0.007 0.026 0.000 0.000 0.000 0.000 0.003 0.004 0.000 0.000 0.083 0.000 0.014 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.009 0.000 0.022 0.037 0.057 0.155 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.062 0.059 0.019 0.139
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.075
0. 000 0.000 0.075 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.041 0.006 0.000
0. 000 0.004 0.017 0.026 0.010 0.020 0.000 0.009 0.003 0.163 0.096 0.077 0.488 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2108.000 310.980 13.020 10.280 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-37

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.001 0.000 0.002 0.010 0.011 0.000
0. 010 0.000
0. 001
0. 000 0.000 0.000 0.000 0.036 0.023 0.040 0.015 0.019 0.009 0.014 0.055 0.080 0.027 0.048 0.019 0.004 0.013 0.001 0.002 0.019 0.386 0.082 0.127 0.064 0.020 0.020 0.026 0.035 0.014
0. 101 0.000
0. 000 0.023 0.058 0.018 0.042 0.085 0.713 0.424 0.126 0.056 0.000 0.009 0.022
0. 126 0.000 0.054 0.018 0.010 0.028 0.103 0.126 0.381 0.363 1.846 0.029 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.016 0.384 0.646 0.198 1.273 0.047
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.094 0.097 0.045 0.284 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.605 0.294 0.135 0.040 0.038 0.065 0.225 0.104 0.181 0.076 0.029 0.056
0. 190 0.622 1.169 0.710 4.538 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2108.000 310. 980 1007.200 95.660 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-38

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.003 0.003 0.000 0.021 0.033 0.068 0.061 0.057 0.035 0.013 0.025 0.017 0.000 0.004 0.002 0.348 0.077 0.037 0.059
0. 009 0.011 0.038 0.142 0.319 0.348
0. 114 0.005
0. 009 0.038 0.000 0.036 0.075 1.317 0.064 0.060 0.036 0.014 0.008 0.025 0.123 0.042 0.301 0.044 0.008 0.000 0.063 0.026 0.050 0.072 0.935 0.052 0.027 0.008 0.000 0.000 0.000 0.047 0.190 0.503 0.062 0.009 0.009 0.000 0.040 0.093 0.049 1.090 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 009 0O.011 0.020 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.196 0.127 0.106 0.023 0.040 0.096 0.381 0.611 1.210 0.255 0.035 0.044 0.118 0.066
0. 192 0.209 3.711 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2108.000 310. 980 822.100 78.230 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-39

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.010 0.004 0.000 0.000 0.001 0.001 0.000 0.000 0.000 0.022 0.035 0.006 0.006 0.026 0.030 0.034 0.148 0.170 0.065 0.025 0.000
0. 000 0.000 0.002 0.001 0.020 0.569 0.065 0.049
0. 019 0.013 0.063 0.008 0.093 0.116 0.220 0.057 0.013
0. 000
0. 000 0.005 0.009 0.106 0.835 0.000 0.015 0.008
0. 000
0. 000 0.000
0. 010 0.158 0.229 0.044
0. 000 0.000 0.000 0.000 0.016 0.015 0.495 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.723 0.010
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.781
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 101 0.070 0.032 0.039 0.097 0.041 0.251 0.501 1.242 0.136 0.013 0.001 0.001 0.008 0.027 0.141 2.702 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS F GROUND LEVEL STABILITY CLASS F 2108.000 310.980 159. 840
56. 950 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-40

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1,

2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.001 0.080 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.096 0.009 0.001 0.000 0.015 0.003 0.002 0.122 0.596
0. 175 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.947 0.033 0.011 0.000 0.000 0.000 0.007 0.010 0.240 0.132 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.444 0.000 0.000
0. 000 0.000 0.000 0.000 0.027 0.043 0.103 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.042 0.012
0. 000
0. 015 0.003 0.019 0.160 0.959 0.416
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.043
1. 669 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2108.000 310. 980 71.170 35.190 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-41

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY DECEMBER 2002 TABLE 15 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

SECOND QUARTER E2-42

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<--l.9 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.028 0.053 0.094 0.007 0.000
0. 000 0.000 0.000 0.000 0.000 0.183
0. 000 0.000 0.000 0.000 0.000 0.055 0.213 0.043 0.147 0.144 0.024 0.017 0.003 0.000 0.000 0.000 0.646 0.013 0.012 0.000 0.004 0.000 0.166 0.078 0.047 0.000 0.000 0.000 0.000 0.002 0.004 0.007 0.005 0.338 0.286 0.113
0. 000
0. 000
0. 000 0.071 0.022 0.000
0. 000 0.000 0.000 0.009 0.000 0.043 0.070 0.046 0.658 0.016
0. 000 0.009
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.02 6 0.031 0.028
0. 111 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.000 0.032 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.315 0.124 0.009 0.004 0.000 0.292 0.341 0.143 0.241
0. 151 0.024 0.025 0.005 0.073 0.139 0.079 1.967 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2114.000 231.920
41. 580
41. 580 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 -METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-43

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.009 0.006 0.005 0.007 0.000 0.000 0.000 0.000
0. 000 0.040 0.000 0.000 0.000 0.000 0.000 0.034 0.016
0. 000 0.032 0.029 0.023 0.028 0.002 0.000 0.000 0.000 0.164 0.000 0.008
0. 000 0.004
0. 000 0.014 0.018 0.000 0.010 0.000 0.000
0. 000 0.000 0.001
0. 009 0.003 0.067 0.036 0.029 0.026 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.009
0. 009 0.006 0.030 0.000 0.147
0. 000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.024 0.000 0.034 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.036 0.047 0.026 0.004
0. 000 0.048 0.046
0. 009 0.048 0.034 0.030 0.038 0.011 0.007 0.064 0.003 0.451 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2114.000 231.920 9.540 9.540 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-44

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.004 0.000 0.015 0.022 0.005 0.005 0.000 0.000
0. 000 0.000 0.000 0.052 0.000 0.000 0.000 0.001 0.001 0.034 0.017 0.000 0.009 0.041 0.018 0.004 0.000
0. 000 0.000 0.000 0.124 0.000 0.009 0.000
0. 011 0.000 0.013 0.008
0. 000 0.018 0.000
0. 000 0.005 0.003 0.007 0.014
0. 000 0.087 0.038 0.007 0.023 0.000 0.000 0.023 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.008 0.045 0.016 0.158 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.022
0. 000 0.022 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.015 0.023 0.012 0.001 0.074 0.024 0.015 0.049 0.046 0.023 0.009 0.003 0.015 0.080 0.016 0.443 TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C 2114.000 231.920
14. 150 9.360 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS C METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-45

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000

0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 001 0.032 0.078 0.047
0. 110 0.098 0.019 0.010 0.000 0.000 0.000 0.000 0.396 0.009 0.020
0. 000 0.009 0.038 0.198 0.180 0.023 0.080 0.175 0.031 0.027 0.010
0. 000 0.004 0.012 0.818 0.046 0.053 0.038 0.008 0.018 0.232 0.064 0.022 0.053
0. 099 0.000 0.016 0.011 0.012 0.051 0.022 0.744 0.163 0.102
0. 019 0.000 0.000 0.048 0.020 0.000 0.000 0.000
0. 000 0.053 0.009 0.038 0.115 0.117 0.684
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.019 0.153 0.172 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.043 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.218 0.175 0.058 0.018 0.056 0.510 0.342 0.091 0.242 0.373 0.050
0. 106 0.031 0.093 0.189 0.305 2.858 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2114.000 231. 920 1073.710
60. 410 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-46

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.004 0.000 0.002 0.001 0.000 0.007 0.000 0.002 0.008 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.024 0.015 0.005 0.015 0.029 0.063 0.157 0.159 0.128 0.178 0.064 0.010 0.008 0.007 0.000 0.000 0.001 0.839 0.106 0.049 0.042 0.057 0.242 0.245 0.072 0.114 0.081 0.160 0.000 0.018 0.030 0.004 0.021 0.018 1.260 0.124 0.041 0.090 0.027 0.021 0.076
0. 020 0.221 0.060 0.124 0.000 0.000 0.000 0.004 0.012 0.037 0.858 0.062 0.044 0.043 0.000 0.008 0.000 0.000 0.095 0.178 0.035 0.000 0.029
0. 000 0.008 0.025 0.017 0.544
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.047 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.047 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.311 0.139
0. 191 0.114 0.334 0.485 0.252 0.559 0.552 0.385 0.010 0.056 0.037 0.017 0.059 0.073 3.571 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2114. 000 231.920 741.240 75.500 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-47

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 I

CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004
0. 000 0.013 0.005 0.010 0.000 0.035 0.027 0.000 0.001
0. 009
0. 000 0.003 0.000 0.000 0.000 0.108 0.018 0.008 0.034 0.032 0.049 0.042 0.070 0.033 0.073 0.020 0.001 0.000 0.003 0.000 0.000 0O.011 0.393 0.049 0.092 0.020 0.017 0.070 0.016 0.014 0.063 0.054
0. 000
0. 000
0. 000 0.002 0.000 0.011 0.024 0.432 0.016 0.016 0.024 0.016 0.009
0. 000
0. 000 0.069
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.015 0.165 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.088 0.115 0.091 0.070 0.137 0.058 0.118 0.288 0.128 0.021
0. 010
0. 000 0.008
0. 000
0. 011 0.050 1.192 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2114.000 231.920 207.340
25. 200 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-48

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.004 0.020 0.024 0.014 0.035 0.037 0.000 0.000 0.006 0.000 0.006 0.000
0. 000 0.000 0.149 0.056 0.019 0.017 0.028 0.010 0.006 0.006 0.027 0.027 0.000
0. 000
0. 000
0. 000 0.000 0.003 0.019 0.219 0.039 0.018 0.000 0.011 0.005 0.000 0.000 0.032 0.017
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 122 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.041 0.021 0.059 0.039 0.020 0.041 0.096 0.044
0. 000 0.006
0. 000 0.006 0.000 0.003 0.019 0.489 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2114.000 231.920
26. 440
10. 330 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-49

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 16 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

THIRD QUARTER E2-50

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.024 0.045 0.057 0.031 0.003 0.000 0.000 0.000 0.000 0.000 0.159 0.000 0.000 0.000 0.000 0.000 0.035 0.118 0.098 0.078 0.062 0.027 0.016 0.000 0.000 0.000 0.000 0.435 0.000 0.000 0.000 0.000 0.003 0.064 0.007
0. 000
0. 000 0.000 0.009 0.005 0.000 0.000 0.000
0. 000 0.087 0.031 0.025 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.064
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.031 0.025 0.000 0.000 0.003 0.098 0.149 0.143 0.135 0.093 0.039 0.021
0. 000 0.000 0.000 0.008 0.745 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2156.000 139. 510 18.920
16. 060 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-51

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 001 0.006 0.008 0.030
0. 000 0.008 0.004
0. 000 0.000
0. 000
0. 000
0. 000 0.058 0.000 0.000 0.000 0.000 0.000 0.017 0.010 0.003 0.009 0.000 0.007 0.005 0.002 0.000 0.000 0.000 0.053 0.000
0. 000
0. 000 0.000 0.000 0.013 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.006
0. 000 0.005 0.028 0.007 0.052 0.005 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010
0. 000 0.007 0.082 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.052 0.005 0.000 0.001 0.036 0.018 0.033 0.010 0.008 0.011 0.005 0.006 0.017 0.000 0.012 0.221 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2156.000 139.510 9.590 4.760 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-52

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.032 0.012 0.007 0.011 0.007 0.000 0.000
0. 000 0.000 0.000 0.069 0.000 0.003 0.000 0.000 0.000 0.015 0.000 0.000 0.018 0.017 0.000 0.002 0.002 0.000 0.000 0.000 0.058 0.000 0.008 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.006 0.009 0.011 0.009 0.008 0.058 0.020 0.035
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.007 0.000 0.025 0.007 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.020 0.046 0.000 0.000
0. 000 0.022 0.032 0.012 0.026 0.028 0.007 0.008 0.019 0.011 0.034 0.016 0.279 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2156.000 139.510 31.740 6.020 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-53

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1,

2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.052 0.078 0.075 0.081 0.096 0.012 0.003 0.001 0.000 0.000 0.000 0.398 0.006 0.015 0.004 0.008 0.034 0.296 0.087 0.028 0.053 0.020 0.008
0. 019 0.037 0.008 0.016 0.009 0.649 0.079 0.053 0.014 0.040 0.025 0.184 0.042 0.000 0.000 0.006 0.000 0.006 0.023 0.046 0.032 0.050 0.602 0.046 0.107 0.052 0.038 0.046 0.068 0.000 0.000 0.008 0.034 0.000 0.000 0.014 0.058 0.081 0.068 0.621 0.000 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.012 0.000 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.131 0.193
0. 070 0.087 0.105
0. 600 0.208 0.103
0. 142 0.156 0.020 0.029 0.075 0.113 0.142
0. 127 2.300 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2156.000 139.510 1182. 010
49. 580 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-54

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24. 4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.005 0.002

0. 000
0. 000 0.000
0. 001 0.001
0. 001 0.01 1 0.000 0.000
0. 000 0.003
0. 000 0.029 0.022 0.014 0.014 0.033 0.061 0.099 0.074 0.028 0.073 0.055 0.019 0.000 0.002 0.000 0.003 0.006 0.503 0.108 0.078 0.044 0.060 0.201 0.193 0.023 0.000 0.000 0.000 0.000 0.005 0.018 0.000 0.007 0.036 0.772 0.086 0.106 0.083 0.027 0.027 0.023 0.050 0.000 0.045 0.040
0. 000
0. 000 0.028 0.008
0. 000 0.006 0.529 0.015 0.061 0.035 0.000 0.053 0.028
0. 000 0.007 0.009 0.035 0.000 0.000 0.015 0.000 0.000 0.000 0.260 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.236 0.258 0.181 0.122 0.342 0.344 0.146 0.037 0.129 0.132 0.030 0.005 0.063 0.008 0.013 0.048 2.093 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2156.000 139.510 717.040 45.130 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-55

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.069 0.026 0.010 0.026 0.018 0.005
0. 001
0. 001
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.012 0.167 0.121 0.167 0.026 0.034 0.077 0.000
0. 000 0.000 0.000 0.000 0.001 0.000 0.001 0.003 0.005 0.004 0.439 0.007 0.031 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.197 0.226 0.042 0.060 0.095 0.005 0.001 0.001 0.000 0.000
0. 001 0.000 0.001 0.003 0.005 0.016
0. 653 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2156.000 139.510 180. 080 14.070 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-56

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW sw SW WNW NW NNW SUBTOTAL

0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.039 0.013 0.006
0. 009 0.003 0.003 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.091 0.037 0.000 0.000 0.019 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.080 0.000 0.008 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.008 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.076 0.021 0.007 0.029 0.008 0.003 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.036 0.180 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2156.000 139.510
16. 620 3.890 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-57

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 17 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL PORTION)

FOURTH QUARTER E2-58

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.006 0.023 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.029 0.000 0.000 0.000 0.000 0.000 0.012 0.032 0.012 0.065 0.024 0.006 0.000 0.000 0.000 0.000 0.000 0.151 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.01 1
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.006 0.000 0.017 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.009 0.009 0.027 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.000 0.000 0.000 0.000 0.012 0.032 0.018 0.088 0.024 0.006 0.000 0.000
0. 000 0.015 0.009 0.224 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2163.000 267.730 4.850 4.850 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-59

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.012 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.030
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.018 0.000 0.015 0.006 0.000
0. 000
0. 000 0.000 0.000 0.000 0.040 0.000
0. 011 0.000
0. 000 0.000 0.007 0.000
0. 000
0. 000 0.000
0. 000 0.005 0.006 0.000 0.000 0.008 0.037 0.024 0.000 0.006 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.008 0.008 0.000 0.007 0.025 0.079
0. 010 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 009 0.019
0. 010 0.048 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.033 0.011 0.006 0.000 0.000 0.007 0.020 0.012 0.030 0.006
0. 000 0.013 0.014 0.009 0.026 0.043 0.233 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2163.000 267.730 5.040 5.040 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-60

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA Tc=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.007 0.006 0.008 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.022
0. 001
0. 000 0.000 0.000 0.000 0.018 0.000 0.043 0.007 0.008
0. 000 0.000 0.000 0.000 0.000 0.000 0.079 0.000 0.000
0. 005 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.006 0.004 0.002 0.018 0.000 0.036 0.032
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.008 0.000 0.027 0.028 0.058 0.153 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.01 1 0.051 0.028 0.018 0.127 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.052 0.000 0.005 0.000 0.000 0.018 0.007 0.050 0.016 0.008 0.000 0.014
0. 015 0.080 0.075 0.076 0.417 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2163.000 267.730 11.780 9.020 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-61

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.003 0.000 0.000 0.000 0.007 0.026 0.066 0.157
0. 111 0.013 0.000 0.000 0.000 0.000 0.000
0. 000 0.382 0.075 0.046 0.018 0.017 0.073 0.271 0.076 0.165 0.052 0.016 0.029 0.019 0.023 0.009 0.035 0.036 0.961 0.121 0.117 0.035 0.030 0.007 0.304 0.123 0.046 0.008 0.018 0.000 0.036 0.092 0.074 0.050 0.136 1.196 0.095 0.114 0.051 0.008 0.017 0.151 0.145 0.008 0.000 0.000 0.000 0.051 0.163 0.189 0.305 0.564 1.862 0.000 0.036 0.069 0.010 0.000 0.035 0.000 0.000 0.000 0.000 0.000
0. 000 0.049 0.313 0.271 0.084 0.866 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.031 0.038 0.000 0.069 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.294 0.313 0.174 0.064 0.104 0.787 0.410 0.382 0.174 0.047 0.029
0. 105 0.327 0.616 0.699 0.820 5.347 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS D GROUND LEVEL STABILITY CLASS D 2163.000 267.730 1226.710 115.650 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-62

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.015 0.009 0.008

0. 010 0.040 0.055 0.096 0.185 0.176 0.019 0.016 0.003 0.005 0.000 0.003 0.029
0. 670 0.101 0.037 0.008 0.030 0.035 0.061 0.120 0.330 0.184 0.074 0.012 0.049 0.023 0.008 0.016 0.086
1. 174 0.075 0.043 0.024 0.006 0.000
0. 101 0.280 0.444 0.255 0.018 0.000 0.055
0. 019 0.014 0.026 0.073 1.432 0.035 0.000
0. 000 0.017 0.000 0.071 0.093
0. 000 0.269 0.174
0. 000 0.008 0.008 0.000 0.016 0.059 0.750 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.012 0.046
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.227 0.088 0.040 0.063 0.075 0.289 0.594 0.963 0.885 0.285 0.028 0.115 0.055 0.022 0.095 0.259 4.081 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2163.000 267.730 738.670
88. 280 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-63

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.015 0.002 0.002 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.023 0.058 0.025 0.007 0.003 0.045 0.029 0.051 0.105 0.098 0.015 0.004 0.004 0.001 0.000 0.000 0.033 0.478 0.123 0.038
0. 000
0. 000 0.026 0.000 0.123 0.220 0.097
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.055 0.683 0.000 0.000 0.000 0.000 0.000 0.000 0.069 0.046 0.108 0.000 0.000 0.000 0.000 0.000 0.006 0.008 0.238 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.041 0.127
0. 000 0.000 0.000 0.000 0.000 0.000 0.018 0.185 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 182 0.063 0.007 0.003 0.071 0.029 0.258 0.415 0.432 0.018 0.004 0.004 0.001 0.000 0.006 0.114
1. 607 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2163.000 267.730 153.490 34.770 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-64

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.010 0.000 0.015 0.003

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.057 0.007 0.002 0.005 0.005 0.011 0.012 0.227 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.349 0.033 0.000
0. 000 0.000 0.000 0.000 0.000 0.040 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.073 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.012
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.012 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.090 0.007 0.002 0.005 0O.011 0.020 0.012 0.282 0.030 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.008 0.468 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2163.000 267.730
22. 460 10.120 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-65

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 18 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

FIRST QUARTER E2-66

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2108.000 1797.020
25. 860 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-67

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 - MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2108.000 1797.020 8.810 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-68

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000

0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.035 0.000 0.000 0.035 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.035 0.000 0.000 0.130 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2108.000 1797.020 13.020

. 2.740 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-69

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.047 0.047
0. 190 0.237 0.190 0.285 0.380 0.190 0.047 0.095 0.047 0.047 0.095 0.047 0.047 0.142 0.285 0.095 0.285 0.095 0.664 0.522 0.190 0.427 0.142 0.237 0.427
0. 095 0.190 0.047 0.275 0.591 0.363 0.134 0.094 0.278 0.785 0.047 0.045 0.138 0.227 0.185 0.231 0.452 0.185 0.181 2.684 2.751 0.761 0.211 0.169 0.423 0.719 0.367 0.812 1.106 0.579 0.246 1.208 1.371 1.728 2.007 2.277 0.698 0.039
0. 000 0.038 0.426 0.192 0.383 1.578 0.850 0.269
0. 191 0.346 1.579
2. 196 1.853 0.214 0.000 0.000 0.000 0.000 0.062 0.140 0.268 0.302 0.238 0.000 0.000 0.068 0.603 0.901 0.067 0.008 0.000
0. 000 0.000 0.000
0. 000 0.021
0. 000 0.027 0.012
0. 000 0.000 0.000 0.004
0. 011 0.003 5.553 4.277
1. 496 0.487 0.777 1.522 2.759 1.871 3.332 2.960 1.265 0.954 2.326 4.153 5.306 4.205 SUBTOTAL 0.000 0.047 2.087 3.890 4.210 17.142 12.917 2.863 0.086 43.242 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2108.000 1797.020 1007.200 911. 540 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-70

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.047 0.047
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 095 0.095 0.142 0.142 0.285 0.047 0.237 0.237 0.095 0.095 0.142 0.095 0.095 0.095 0.047 0.095 0.047 1.992 0.095 0.332 0.237
0. 190 0.285 0.142
0. 190 0.427 0.380 0.237 0.237 0.332 0.285 0.142 0.142 0.332 3.985 0.180 0.185 0.223 0.141 0.512 0.225 0.811 0.680 0.727 0.179 0.182 0.184 0.409 0.182 0.414 0.181 1.594 1.154 0.750 0.597 0.298 0.793 1.545 2.361 2.068 0.782 0.502 0.259 0.334 0.126 0.375 1.121 0.154
0. 000 0.000 0.079 0.000 0.194 0.653
1. 895 2.507 0.966 0.273 0.000 0.000 0.078 0.233 0.390 7.422 0.000 0.037 0.000 0.000 0.000 0.000 0.268 0.472 0.789 0.068 0.000 0.000 0.000 0.000 0.000 0.000 1.635 0.000
0. 000 0.000 0.000 0.000 0.000 0.007 0.021 0.042 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.081 2.119 1.851 1.353 1.291 1.142 1.592 3.711 5. 952 6.655 2.435 1.289 0.869 1.123 0.576 1.259
2. 072 35.288 5.416 14.662 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2108.000 1797.020 822.100 743. 870 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-71

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000

0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.095 0.095 0.047
0. 000 0.190
0. 000 0.047
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.5 69 0.047 0.047
0. 095 0.047 0.047 0.047 0.095 0.095 0.237 0.142 0.000 0.000 0.047
0. 000 0.000 0.047 0.996 0.000 0.045 0.142 0.092 0.045 0.138 0.182 0.094 0.374 0.000 0.047 0.000 0.000 0.000 0.000 0.046 1.204 0.165 0.083 0.250 0.042 0.125 0.254 0.371 0.333 0.124 0.043 0.040
0. 000
0. 000
0. 000
0. 000 0.126
1. 954 0.000 0.000 0.000 0.000 0.000 0.000 0.079 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.157 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.259 0.222 0.581 0.276 0.264 0.439 0.916 0.561 0.782 0.185 0.088 0.000 0.047 0.000 0.000 0.259 4.881 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2108.000 1797.020 159. 840 102. 890 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-72

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW sUBToTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.095 0.000
0. 190 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.380 0.000 0.000 0.000 0.000 0.047 0.047 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.095 0.332 0.045 0.046 0.000 0.000 0.000 0.185 0.047 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.368 0.000 0.000 0.000 0.040 0.085 0.127 0.210 0.042 0.000 0.042 0.000 0.000 0.000 0.000 0.000 0.043 0.588
0. 000 0.000 0.039 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.045 0.046 0.087 0.040 0.228 0.359 0.541 0.087 0.000 0.089 0.000
0. 000
0. 000 0.047 0.000 0.138 1.707 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2108.000 1797.020 71.170 35.980 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/05/15 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-73

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY DECEMBER 2002 TABLE 19 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

SECOND QUARTER E2-74

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2114.000 1882.080 41.580 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-75

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000

0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2114.000 1882.080 9.540 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-76

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.043 0.043
0. 000 0.000 0.000 0.000 0.000 0.128 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.004 0.000
0. 000 0.004
0. 000
0. 000
0. 000
0. 000 0.000 0.042 0.000 0.000 0.047 0.090 0.043 0.000
0. 000 0.004
0. 000
0. 000 0.227 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2114. 000 1882.080 14.150 4.790 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-77

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000
0. 000 0.000
0. 000 0.047 0.000 0.047 0.095 0.000 0.047 0.047 0.284 0.473 0.378 0.662 0.520 0.473 0.142 0.095 0.142 0.047 3.453 0.331 0.237 0.142 0.189 0.047 0.237 0.757 0.662 0.757 0.5 68 0.615 0.851 0.520 0.378 0.473 0.095 6.859 0.228 0.272 0.225 0.185 0.136 0.862 1.139 0.682 0.548 0.496 0.543 0.139 0.318 0.320 0.731 0.364 7.186 1.277 1.414 0.703 0.258 0.170 2.324 2.642 1.820 1.257 1.878 1.208 0.125 0.042 0.701 1.551 0.695 1.920 0.965 0.077
0. 000 0.000 0.655 1.922 0.735 1.461 1.432 0.193 0.229
0. 000
0. 000 0.427 0.576 0.414 0.110 0.000 0.000 0.000 0.000 0.393 0.111 0.246 0.212 0.000 0.018 0.000 0.021 0.064 0.121 1.711 0.000 0.000
0. 000 0.000 0.000
0. 000 0.001 0.004 0.011
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.017 4.170 3.045 1.241 0.632 0.401
4. 124 7.139 4. 487 4. 659 5.248 3.079 1.883 1.022 1.515 3.388 1.898 47.933 18.066 10.593 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2114. 000 18 82.080 1073.710 1013.300 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-78

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION CALM WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000
0. 000 0.047
0. 000
0. 000
0. 000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.095 0.189 0.142 0.047 0.189 0.189 0.237 0.142 0.378 0.284 0.189 0.426 0.284 0.142 0.189 0.095 0.331 0.378 0.331 0.378 0.520 0.662 0.378 0.331 0.378 0.142 0.426 0.142 0.047 0.237 0.363 0.687 0.412 0.273 0.591 0.912 0.681 0.637 0.277 0.271 0.316 0.276 0.367 0.045 0.047 0.136 0.494 1.206 0.832 0.502 0.853 2.277 1.711 1.037 1.118 0.821 0.169 0.254 0.125 0.128 0.371 0.250 0.348 0.154 0.196 0.194 0.000 0.118 0.888 0.853 0.653 0.733 0.000 0.078 0.000 0.039 0.077 0.039 0.000 0.000
0. 000
0. 000 0.000 0.000 0.155 0.359
0. 000 0.056
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.008 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.441 2.189 1.866 1.536 1.965 3.733
4. 155 3.745 2.669 2.353 1.289 1.034
1. 107 0.780 0.827 0.803 SUBTOTAL 0.000 0.095 3.027 4.967 6.294
12. 147 4.369 0.570 0.024 31.492 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2114.000 1882. 080 741. 240 665.740 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-79

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.047 0.095
0. 000 0.095 0.095 0.047
0. 000 0.000 0.000 0.095 0.568 0.047 0.047 0.047 0.237 0.095 0.047 0.237 0.189 0.142 0.237 0.237 0.095 0.142 0.284
0. 000 0.047 2.129 0.045 0.088 0.226 0.408 0.311 0.088 0.184 0.272 0.455 0.091 0.140 0.000 0.047 0.000 0.000
0. 000 2.355 0.000 0.739 0.377 0.254 0.378 0.288 0.376 0.291 0.168 0.126 0.043 0.000
0. 000 0.000 0.087 0.084 3.211 0.000 0.000 0.157 0.157 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.353 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.092 0.875 0.854 1.055 0.831 0.463 0.844 0.847 0.765 0.548 0.514 0.142 0.189 0.284 0.087 0.226 8.616 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2114.000 1882. 080 207.340 182. 140 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-80

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.047 0.047 0.000 0.000 0.000 0.000
0. 000 0.000 0.095 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.189 0.000 0.044 0.047 0.000 0.000 0.000 0.092 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.228
0. 000 0.041 0.043 0.123 0.000
0. 000 0.044 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.250 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.086 0.137 0.123 0.000 0.000 0.183 0.095 0.092 0.047 0.000 0.000 0.000 0.000 0.000
0. 000 0.762 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2114.000 1882.080
26. 440 16.110 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/08/06 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-81

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 20 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

THIRD QUARTER E2-82

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.090 0.000 0.000 0.000 0.000 0.000 0.090 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.043 0.000 0.000 0.000 0.000 0.000 0.043 0.000
0. 000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.133 0.000
0. 000 0.000 0.000
0. 000 0.133 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2156.000 2016.490 18.920
2. 860 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-83

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.093
0. 000
0. 000
0. 000
0. 000 0.000 0.093 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.043 0.042 0.000 0.000
0. 000
0. 000 0.085 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.182 0.042 0.000
0. 000
0. 000
0. 000 0.224 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS B ELEVATED STABILITY CLASS B 2156.000 2016.490 9.590 4.830 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-84

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 - SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.093 0.046 0.046 0.046 0.000 0.000 0.000 0.232
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.045 0.000 0.000 0.089 0.449 0.045 0.089 0.000 0.000 0.000 0.716 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.126 0.000 0.000 0.042 0.000 0.000 0.000 0.207 0.000 0.038 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.038
0. 000 0.000
0. 000 0.000 0.045 0.000
0. 000 0.308 0.495 0.092
0. 177
0. 000
0. 000 0.000
1. 193 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 215 6.000 2016. 4 90
31. 740 25.720 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-85

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW

0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.046 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.046
0. 000 0.000
0. 000
0. 000 0.000 0.371 0.186 0.139 0.093 0.186 0.139 0.603 0.835 0.881 1.160 0.881 0.557 0.417 0.278 0.371 0.186 0.417 0.325 0.464 0.093 0.186 0.325 1.020 2.365 1.623 1.855 1.902 2.041 0.974 0.510 0.232 0.093 0.183 0.492 0.179 0.000 0.314 0.403 0.945 1.609 1.512 0.937 0.905 0.634 1.035 1.115 0.705 0.229 1.129 1.212 0.487 0.366 0.203 0.851 1.922 2.401 1.718 1.229 0.207 0.000 0.417 0.581 0.942 0.775
0. 190 0.457 0.077 0.000 0.037 0.154
1. 624 1.093 0.340 0.376 0.000 0.000 0.000 0.038
0. 000 0.075 0.000 0.000 0.000 0.000 0.000 0.000 0.404 0.173 0.013 0.030 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.006 0.001 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 2.291 2.671 1.392 0.551 0.926 1.872 6.519
8. 482 6.087 5.587 3.942 3.231 2.844
2. 523 2.250 1.357 SUBTOTAL
0. 000 0.093 7.282 14.425 11.197 14.440 4.461 0.620 0.007 52.525 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2 156.000 2016.490 1182. 010 1132.430 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY -

12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-86

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.046 0.000 0.186 0.000
0. 000 0.139 0.000 0.046 0.000 0.139
0. 000 0.000
0. 000 0.557 0.139 0.417 0.278 0.232 0.464 0.232 0.278 0.510 0.325 0.325 0.557 0.510 0.325 0.139 0.232 0.093 5.056 0.371 0.4 17 0.881 0.417 0.928 0.788 0.557 0.742 0.788 0.881 0.742 0.742 0.510 0.186 0.232 0.278 9.462 0.313 0.398 0.442 0.578 0.401 0.497 0.675 0.537 0.269 0.130 0.134 0.089 0.134 0.179 0.224 0.312 5.312 0.604 1.661 1.132 0.488 0.283 1.822 0.528 0.592 0.576 0.573 0.082 0.125 0.409 0.081 0.250 0.166 9.372 0.231 0.460 0.115 0.000 0.037 0.113 0.037
0. 151 0.038 0.000 0.000 0.000 0.000 0.038 0.000 0.000 1.219 0.000 0.029 0.000 0.000 0.029 0.077 0.018 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.034 0.000 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
1. 657 3.383 2.849 1.762 2.141 3.715 2.093 2.532
2. 135 1.910 1.561 1.466 1.516 0.623 0.973 0.849 0.000 31.165 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS E ELEVATED STABILITY CLASS E 2156.000 2016. 4 90 717.040 671.910 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-87

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.186 0.139 0.046 0.093 0.046 0.046 0.000 0.093
0. 000 0.04 6 0.046 0.046 0.000 0.000 0.000 0.046 0.835 0.139 0.046 0.139 0.139 0.046 0.093 0.186 0.232 0.093
0. 000 0.186
0. 000 0.000 0.000 0.046 0.139 1.484 0.220 0.134 0.135 0.179 0.177 0.046 0.044 0.043 0.000 0.136 0.000 0.045 0.000 0.000 0.046 0.132 1.339 0.412
1. 173 0.769 0.332 0.500 0.359 0.000 0.000
0. 000 0.084 0.000 0.000
0. 000
0. 000 0.000 0.167 3.795
0. 000 0.115 0.038
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.154
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.957
1. 608 1.128 0.789 0.769 0.545 0.229 0.368 0.139 0.267 0.232 0.092
0. 000 0.000 0.093 0.484 7.700 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2156.000 2016.490 180. 080 166. 010 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-88

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.046
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.046 0.000
0. 000 0.088 0.045
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.133 0.161 0.122 0.082
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.365 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.161 0.168 0.169 0.045 0.000 0.000 0.046 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.590 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2156.000 2016. 4 90
16. 620 12.730 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-89

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 21 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (ELEVATED PORTION)

FOURTH QUARTER E2-90

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-l.9 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2163.000 1895.270 4.850 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-91

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2163. 000 1895.270 5.040 0.000 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-92

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.046 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.035
0. 000
0. 000
0. 000 0.035 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.046 0.000 0.000 0.035 0.000 0.000 0.046 0.128 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2163.000 1895.270 11.780 2.760 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT, 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-93

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL CALM 0.6-1.4 1.5-3.4 0.000 0.000 0.185 0.000 0.000 0.139 0.000 0.000 0.092 0.000 0.000 0.139 0.000 0.000 0.231 0.000 0.000 0.139 0.000 0.000 0.231 0.000 0.000 0.416 0.000 0.046 0.370 0.000 0.000 0.185 0.000 0.000 0.601 0.000 0.000 0.231 0.000 0.046 0.139 0.000 0.046 0.185 0.000 0.046 0.277 0.000 0.000 0.277 0.000 0.185 3.837 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D

?ART 2 OF 2 ELEVATED RELEASE MOD OCT 1, 2002 -

DEC 31, 2002 WIND SPEED(MPH) 3.5-5.4 5.5-7.4 7.5-12.4 0.416 0.669 1.953 0.693 0.798 1.460 0.693 0.671 0.607 0.231 0.223 0.208 0.462 0.489 0.164 0.416 1.024 0.977 0.509 0.669 1.344 0.601 0.539 1.212 0.370 0.133 1.526 0.509 0.223 0.605 0.462 0.043 0.686 0.462 0.136 0.720 0.509 0.404 1.220 0.555 0.488 1.510 0.555 0.713 1.418 0.832 0.706 2.250 8.276 7.928 17.861 E

12.5-18.4 1.137 0.306 0.000 0.075 0.038 0.112 1.274 1.317 0.712 0.263 0.152 0.379 0.600 0.977 1.608 2.067 11.017 18.5-24.4 0.167 0.033 0.043 0.000 0.000 0.012 0.381 0.210 0.249 0.120 0.000 0.000 0.078 0.440 0.267 0.170

2. 170

>=24.5 0.000

0. 000 0.000 0.000 0.000 0.000 0.042 0.006
0. 009 0.028 0.000 0.000 0.000 0.008 0.000 0.000 0.093 TOTAL 4.527 3.429 2.108 0.877 1.385 2.680 4.449 4.302 3.413 1.933 1.944 1.929 2.995 4.209 4.886 6.301 51.367 HOURS HOURS HOURS HOURS 2163.000 18 95.270 1226.710 1111. 060 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-94

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24. 4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.092 0.046 0.000 0.092 0.000
0. 000 0.046 0.000 0.046 0.000 0.046 0.046 0.092 0.139 0.000 0.000 0.647 0.139 0.092 0.092 0.277 0.139 0.046 0.277 0.277 0.324 0.370 0.509 0.231 0.092 0.185 0.139 0.185 3.375 0.370 0.416 0.185 0.324 0.231 0.324 0.416 0.647 0.509 0.462 0.370 0.370 0.324 0.092 0.185 0.231 5.455 0.406 0.618 0.404 0.221 0.536 0.571 0.794 0.675 0.496 0.488 0.353 0.315 0.183 0.043 0.266 0.659 7.028 1.061 1.216 0.243 0.247 0.245 0.661 1.070 0.676 0.878 0.406 0.247 0.408
0. 119 0.043 0.200 1.137 8.857 0.228 0.075 0.075 0.037 0.037 0.150 0.564 0.790 0.905 0.112 0.000
0. 000 0.153 0.037 0.077 0.227 3.468 0.000 0.024 0.027 0.000 0.000 0.012 0.385 0.410 0.254 0.050 0.000 0.000
0. 000 0.000 0.000 0.000
1. 160
0. 000 0.000
0. 000 0.000 0.000 0.000 0.043 0.014 0.008 0.012 0.000 0.000 0.000
0. 000 0.000 0.000 0.078 2.296 2.487 1.026
1. 198
1. 188 1.763 3.595 3.490 3.420 1.902 1.525 1.371 0.963 0.540 0.866 2.439
30. 069 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2163.000 18 95.270 738. 670 650. 390 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-95

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE WIND DIRECTION N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL CALM 0.6-1.4 1.5-3.4 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.139 0.000 0.000 0.046 0.000 0.000 0.092 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.601 OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F OCT 1, 2002 -

DEC 31, 2002 WIND SPEED(MPH) 3.5-5.4 5.5-7.4 7.5-12.4 0.046 0.046 0.413 0.092 0.087 0.279 0.000 0.224 0.126 0.000 0.000 0.082 0.000 0.087 0.000 0.092 0.046 0.207 0.139 0.491 0.248 0.324 0.088 0.000 0.277 0.228 0.041 0.324 0.178 0.042 0.185 0.000 0.000 0.000 0.000 0.000 0.092 0.045 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.280 1.618 1.519 1.718 12.5-18.4 0.000 0.000 0.000

0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 18.5-24. 4 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032

>=24.5

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 TOTAL 0.506 0.551 0.350 0.128 0.087 0.438 1.048 0.458 0.639 0.589 0.185 0.000 0.137 0.046 0.046 0.280 5.489 HOURS HOURS HOURS HOURS 2 163.000 1895.270 153. 4 90 118.720 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-96

SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24. 4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW -

WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000 0.000 0.046
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.046 0.000 0.000 0.000-
0. 000
0. 000 0.000 0.000 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.000 0.131 0.000 0.000 0.000 0.046 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.177 0.123 0.039 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.162 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.123 0.039 0.131 0.000 0.000 0.046 0.046 0.092 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.571 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2163.000 1895.270 22.460 12.340 METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2003/02/07 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-97

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 22 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FIRST QUARTER E2-98

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 0

0 2120 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-99

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000

0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 0

0 2120 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 00

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000

0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.047
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000
0. 000 0.047 0.000 0.000 0.142 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 3

3 2120 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED = 10.90 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 01

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.047
0. 000
0. 000 0.000
0. 000 0.000
0. 000
0. 000 0.047 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.094 0.047 0.094 0.094 0.142 0.094 0.236 0.283 0.142 0.236 0.094 0.094 0.047 0.047 0.000 0.189 0.047 0.142 0.047 0.142 0.189 0.377 0.377 0.142 0.330 0.236 0.142 0.142 0.189 0.094 0.047 0.236 0.377 0.236 0.047 0.142 0.236 0.519 0.283 0.047 0.094 0.047 0.236 0.425 0.283 0.189 0.142 2.500 2.783 0.896 0.236 0.330 0.660 0.425 0.377 0.660 0.708 0.472 0.377 0.991 1.509 0.849 1.509 3.208
1. 557 0.236 0.094 0.094 0.330 0.189 0.519 1.840
1. 462 0.566 0.236 0.708
2. 170 2.170 2.689 0.708 0.142 0.000 0.000 0.047 0.330 0.236 0.613 0.896 0.566 0.142 0.236 0.377 1.415 1.934 0.566 0.189 0.000
0. 000
0. 000 0.000 0.047 0.236 0.000 0.283 0.142
0. 000 0.000 0.094 0.566 0.236 0.142 7.075 5.000 1.557 0.519 0.849
1. 934 2.075 2.406
4. 198 3.443 1.698 1.321 2.830 6.179 5.519 5.094 SUBTOTAL 0.000 0.094 1.745 2.830 3.538 15.283 18.066 8.208 1.934
51. 698 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2132 1100 1096 2120 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED = 13.42 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-102

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.047 0.236 0.142 0.094 0.142 0.189 0.000 0.047 0.142 0.094 0.047 0.047 0.000 0.047 0.047 1.415 0.047 0.142 0.142 0.236 0.094 0.094 0.047 0.142 0.189 0.142 0.189 0.094 0.094 0.094 0.142 0.047
1. 934 0.094 0.189 0.142 0.094 0.142 0.189 0.283 0.142 0.283 0.377 0.189 0.189 0.000 0.094 0.330 0.236 2.972 0.896 0.613 0.472 0.660 0.472 0.472 1.038 1.462 2.594
0. 991 0.566 0.283 0.613 0.472 0.189 0.472 12.264 1.321 1.038 0.377 0.425 0.142 0.236 0.755 2.453 4.340 1.462 0.708 0.283 0.330 0.189 0.377 0.849
15. 283 0.047 0.094 0.047 0.047 0.000 0.142 0.472 1.509 2.075 0.519 0.047 0.000 0.000 0.000 0.142 0.094 5.236 0.000 0.000 0.000 0.000 0.000 0.000 0.330 0.566 0.896 0.283
0. 000 0.000
0. 000 0.000 0.000 0.000 2.075 2.500
2. 123 1.415
1. 604 0.943 1.274 3.113 6.274
10. 425 3.915 1.792 0.896 1.085 0.849 1.226 1.745
41. 179 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 881 873 2120 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED:

2002/05/15 MEAN WIND SPEED = 13.54 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-103

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.189 0.000 0.000 0.047 0.047 0.094 0.000 0.047 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.330 0.047 0.000 0.047 0.000 0.142 0.000 0.094 0.047 0.094 0.094 0.047 0.000 0.047 0.000 0.000 0.000 0.660 0.094 0.094 0.189 0.189 0.000 0.094 0.425 0.236 0.425 0.425 0.000 0.000 0.000 0.000 0.000 0.047 2.217 0.094 0.142 0.236 0.047 0.047 0.047 0.142 0.472 0.094 0.142 0.094 0.000 0.000
0. 000
0. 000 0.047 1.604 0.000 0.000 0.047
0. 000
0. 000 0.000 0.000 0.000 0.094 0.000 0.000
0. 000 0.000 0.000
0. 000 0.047 0.189 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.236 0.236 0.613 0.283 0.330 0.142 0.802 0.802 0.708 0.708 0.142
0. 000 0.047 0.000
0. 000 0.142 5.189 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 110 110 2120 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED = 10.97 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 04

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant JAN 1, 2002 -

MAR 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.142 0.000 0.000 0.000 0.094 0.047 0.047 0.047 0.000 0.047 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.377 0.000 0.094 0.000 0.000
0. 000 0.142 0.377 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.755 0.000 0.094 0.000 0.047 0.047 0.047 0.094 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.425 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000
0. 000 0.000 0.094
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 O. 000 0.000 0.000 0.000 0.000 0.189 0.000 0.142 0.094 0.236 0.566 0.142 0.189 0.189 0.000 0.000 0.000 0.000 0.000 0.047 1.792 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2132 38 38 2120 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/05/15 MEAN WIND SPEED = 10.36 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 05

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 23 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES SECOND QUARTER E2-106

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS OF VALID STABILITY OBSERVATIONS HOURS OF STABILITY CLASS A HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 0

0 2134 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 07

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 0

0 2134 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-108

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047
0. 000 0.047 0.000 0.000 0.000 0.000 0.000 0.094 0.000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.141 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000
0. 000
0. 000 0.000 0.047 0.000
0. 000 0.047 0.047 0.094 0.000
0. 000 0.047
0. 000
0. 000 0.281 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 6

6 2 134 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED = 12.33 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-109

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24. 4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.000 0.047 0.047 0.094 0.094 0.234 0.375 0.187 0.515 0.375 0.375 0.047 0.047 0.000 2.484 0.141 0.187 0.187 0.141 0.000 0.141 0.422 0.515 0.328 0.656 0.515 0.703 0.422 0.515 0.4 69 0.047 5.389 0.281 0.234 0.141 0.187 0.000 0.515 0.890 0.703 0.422 0.281 0.234 0.281 0.422 0.515 0.609 0.187 0.984 1.687 0.750 0.375 0.281 3.140 2.156 1.687 1.359 1.640 0.984 0.141 0.281 0.937 1.500 0.609 2.015 1.265 0.328 0.000 0.047 1.781 1.968 1.218 1.453 1.781 1.312 0.141 0.047 0.187 0.562 0.656
1. 172 0.281 0.000
0. 000 0.000 0.234 1.500 0.422 0.750
1. 125 0.375 0.281 0.000 0.000 0.094 0.469 6.701 0.047 0.000
0. 000
0. 000 0.000 0.000 0.187 0.281 0.141 0.187 0.000 0.094 0.000 0.047 0.094 0.047
1. 125
4. 639 3.702 1.406 0.750 0.375 5.904 7.216 S.061 4.827 5.858 3.936 2.015 1.546 2.249 3.374 2.062 54.920 5.904 18.510 14.761 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 1180 1172 2134 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED = 11.82 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 10

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 O.000 0.000 0.000 0.000 0.000

0. 000 0.047 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.000 0.047
0. 000 0.000 0.047 0.000 0.000 0.141 0.000 0.141 0.187 0.234
0. 000 0.234 0.328 0.141 0.187 0.234 0.094 0.047 0.000 0.094 0.000 0.094 0.234 0.281 0.234 0.094 0.141 0.094 0.234 0.234 0.375 0.094 0.047 0.234 0.328 0.234 0.094 0.281 0.281 0.422 0.422 0.234 0.375 0.234 0.094 0.187 0.281 0.141 0.141 0.187 0.890 0.843 0.609 0.656 1.359 1.453 1.687 1.500 0.515 0.469 0.515 0.281 0.328 0.141 0.281 0.609 0.843 0.656 0.328 0.234 1.734 1.828 0.984 1.500 1.172 0.281 0.187 0.141 0.047 0.234 0.234 0.281 0.141 0.234 0.187 0.000 0.000 0.328 0.562 0.422 0.656 0.047 0.000
0. 000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.141 0.422 0.094 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.359 2.296 2.062 1.218 1.406 3.655 4.592 4.499 4.077 2.905 1.406 1.359 1.031 1.218 0.937 0.843 SUBTOTAL 0.000 0.281 1.968 2.296 3.983 11.715 11.012
2. 952 0.656 34.864 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 747 744 2134 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED = 11.68 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-111

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.094 0.047 0.000 0.000 0.047 0.047 0.047 0.000 0.000 0.047 0.000 0.000
0. 000 0.328 0.047 0.000 0.047 0.000 0.047 0.000 0.094 0.000 0.047 0.047 0.000 0.094 0.094 0.047 0.000 0.094 0.656 0.000 0.000 0.000 0.047 0.000 0.047 0.094 0.234 0.000 0.141 0.047 0.000 0.000 0.141 0.000 0.047 0.797 0.047 0.187 0.328 0.281 0.469 0.469 0.375 0.187 0.422 0.234 0.422 0.094 0.047 0.187 0.000 0.047 3.796 0.000 0.422 0.234 0.375 0.141 0.234 0.187 0.515 0.562 0.187 0.234 0.000 0.000 0.000 0.047 0.047 3.187 0.000 0.094 0.141 0.141
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.375 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.094 0.703 0.750 0.937 0.703 0.750 0.750 0.984 1.078 0.656 0.703 0.187 0.187 0.375 0.047 0.234 9.138 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS TOTAL HOURS TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 195 195 2134 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED = 11.21 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-112

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant APR 1, 2002 -

JUN 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000
0. 000 0.047 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.094
0. 000 0.047 0.000 0.000 0.000 0.000 0.141 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.094 0.000 0.047 0.000 0.000
0. 000 0.000 0.000 0.234 0.000 0.047 0.094 0.047 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.187 0.000 0.000
0. 000 0.000 0.141 0.000 0.000 0.000 0.047 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.187 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.094 0.094 0.047 0.141 0.000 0.000 0.047 0.141 0.094 0.094 0.047 0.000 0.000 0.000 0.000 0.797 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2145 17 17 2 134 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/08/06 MEAN WIND SPEED =

8.85 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-113

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY DECEMBER 2002 TABLE 24 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES THIRD QUARTER E2-114

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000

0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.139 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 139 0.000 0.000
0. 000
0. 000 0.000
0. 139 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 3

3 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

9.70 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-115

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA Tc=-1.7 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.185 0.000 0.000 0.000 0.000 0.000 0.185 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.232
0. 000
0. 000
0. 000
0. 000 0.000 0.232 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 5

5 2 157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

8.12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-116

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000

0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000
0. 000 0.000 0.000
0. 000 0.000 0.046 0.000 0.000 0.046 0.139 0.046 0.093 0.000 0.000 0.000 0.371 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.278 0.325 0.046 0.093 0.000 0.000 0.000 0.742 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.371 0.464 0.093 0.185
0. 000
0. 000 0.000 1.252 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 27 27 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

8.55 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-117 J

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000
0. 000 0.04 6 0.325 0.185 0.093 0.232 0.139 0.093 0.371 0.742 0.788 1.020 0.834 0.371 0.232 0.417 0.185 0.185 0.556 0.232 0.185 0.232 0.093 0.325 1.020 1.298 1.344 0.834 1.113 1.623 0.742 0.464 0.232 0.093 0.139 0.464 0.232 0.000 0.139 0.278 1.066 1.669 0.834 0.881 0.742 1.113 1.205 0.927 0.464 0.232 0.742 0.974 0.278 0.185 0.278 1.066 1.854 2.411 2.364 1.808 1.484 0.417 0.881 1.113 1.205 0.603 0.974 0.881 0.371 0.325 0.139 0.881 2.086 1.391 0.649 0.834 0.046 0.000 0.093 0.000 0.093 0.325 0.000 0.046 0.000 0.000 0.046 0.046 1.066 0.649 0.139 0.232 0.000
0. 000 0.000 0.000 0.000 0.046
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.139 0.046 0.093 0.046 0.000
0. 000 0.000 0.000 0.000
0. 000 2.735 2.782 1.159 0.974 0.834
2. 689 7.603 8.206 6.259 5.656 4.219 3.523 3.153 2.92 1
2. 179 1.530 SUBTOTAL 0.000 0.093 6.212 10.385
10. 385
17. 663 9.087 2.272 0.325
56. 421 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =

8.71 2189 1233 1217 2157 0

DATE PRINTED: 2002/12/03 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-118

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NB W SUBTOTAL 0.000

0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.093 0.000 0.139 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.278 0.185 0.139 0.139 0.046 0.232 0.232 0.371 0.139 0.093 0.371 0.232 0.232 0.232 0.046 0.139 0.139 2.967 0.371 0.093 0.232 0.185 0.325 0.371 0.927 0.510 0.464 0.556 0.649 0.649 0.742 0.139 0.139 0.278 6.630 0.139 0.325 0.371 0.325 0.046 0.325 0.649 0.603 0.556 0.325 0.278 0.278 0.464 0.232 0.232 0.139 5.285 0.417 0.742 0.742 0.834 0.371 1.113 0.974 0.927 0.603 0.464 0.556 0.232 0.4 17 0.139 0.510 0.232 9.272 0.695 1.484 1.020 0.556 0.185 0.974 0.788 0.139 0.417 0.603 0.046 0.046 0.139 0.232 0.046 0.046 7.418 0.046 0.371 0.278 0.000 0.000 0.093 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.881 0.000
0. 000
0. 000
0. 000 0.185 0.093 0.046 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.325 1.854 3.153 2.782
1. 947 1.344 3.199 3.848 2.364 2.272 2.318 1.762 1.437 1.994 0.788
1. 159 0.834 33.055 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 726 713 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED =

9.05 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-119

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.046 0.000 0.046
0. 000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.093
0. 000 0.000 0.000 0.093 0.046 0.046 0.000 0.046 0.046 0.000 0.046 0.000 0.000
0. 000 0.000 0.000 0.325 0.093 0.139 0.046 0.046 0.046 0.000 0.093 0.046 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.046 0.695 0.000 0.139
0. 000
0. 000 0.185 0.185 0.093 0.185 0.139 0.093
0. 000
0. 000 0.000 0.000 0.000 0.046 1.066 0.371 0.232 0.278 0.185 0.417 0.278 0.093 0.093 0.139 0.139 0.093 0.000 0.000 0.046 0.093 0.000 2.457 0.371 0.927 0.556 0.4 17 0.093 0.371 0.139 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.093 3.060 0.000 0.185 0.325 0.046 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.556 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.834 1.623 1.205 0.788 0.788 0.927 0.4 17 0.417 0.325 0.325 0.185 0.046 0.046 0.046 0.093 0.185 8.252 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 180 178 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED = 11.12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-120

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant JUL 1, 2002 -

SEP 30, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.046
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.046 0.185 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.232 0.046 0.046 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.232 0.046 0.046
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.046 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.093 0.093 0.139 0.046 0.185 0.000 0.046 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.046 0.649 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2189 15 14 2157 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2002/12/03 MEAN WIND SPEED = 13.66 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 21

RADIOLOGICAL IMPACT ASSESSMENT BROWNS FERRY NUCLEAR PLANT JANUARY -

DECEMBER 2002 TABLE 25 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FOURTH QUARTER E2-1 22

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 0

0 2176 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-123

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B

(-1.9< DELTA T<=-1.7 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.000 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 0

0 2 176 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =

0.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 24

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C

(-1.7< DELTA T<=-1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24. 4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000

0. 000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000
0. 000 0.046
0. 000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.046 0.046
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000
0. 000
0. 000 0.000
0. 000 0.000 0.046
0. 000 0.000 0.046 0.000
0. 000 0.046 0.138 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 3

3 2176 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED = 11.13 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-125

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D

(-1.5< DELTA T<=-0.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000 0.000
0. 000 0.000
0. 000
0. 000 0.000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.138 0.046 0.138 0.046 0.138 0.000 0.046 0.230 0.414 0.230 0.230 0.184 0.276 0.138 0.276 0.322 0.184 2.895 0.276 0.506 0.276 0.046 0.368 0.276 0.230 0.551 0.368 0.092 0.873 0.368 0.551 0.414 0.551 0.506 6.250 0.597 0.551 0.643 0.138 0.276 0.689 0.506 0.597 0.092 0.092 0.184 0.230 0.368 0.322 0.643 0.368 2.022
1. 654 0.827 0.368 0.643 1.425 1.103 1.241
1. O11 0.597 0.551 0.276 1.057 1.700 1.149 2.390 1.471 0.827 0.368 0.092 0.138 0.551 1.563 1.379 1.379 0.460 0.643
0. 919 0.873 1.057 1.700 2.619
16. 039 0.414 0.046 0.000 0.092 0.046 0.046 1.149 0.827 0.551 0.276 0.046 0.230 0.735 1.011 0.827 1.057 7.353 0.000 0.000 0.092 0.000
0. 000 0.092 0.689 0.460 0.276 0.368
0. 000
0. 000 0.138
0. 138 0.092
0. 000 2.344 4.825 3.722 2.298 0.873 1.471 3.125 5.469 5.469 3.906 2.114 2.482 2.298 3.860 4.917 5.331 7.169
59. 329 6.296 18.015 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 1296 1291 2176 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED = 12.12 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-126

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E

(-0.5< DELTA T<= 1.5 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.046 0.046

0. 000 0.000 0.092 0.092 0.046 0.092 0.000 0.046 0.046 0.046 0.000 0.046 0.092 0.046 0.184 0.046 0.138 0.322 0.322 0.230 0.138 0.276 0.046 0.046 0.138 0.092 0.092 0.276 0.184 0.138 0.046 0.046 0.138 0.138 0.092 0.322 0.092 0.276 0.046 0.184 0.276 0.230 0.092 0.138 0.184 0.046 0.230 0.184 0.138 0.230 0.368 0.460 0.4 60 0.276 0.276 0.138 0.138 0.092 0.138 1.057 1.149 0.873 0.322 0.506 0.827
1. 195 1.195 0.597 0.827 0.643 0.551 0.230 0.138 0.368 0.506 0.965 0.965 0.322 0.138 0.230 0.368 0.368 1.057 1.746 0.414 0.414 0.551 0.230 0.000 0.276 0.735 0.046 0.046 0.138 0.000 0.046 0.138 0.781
0. 919 0.919 0.046 0.046 0.046 0.092 0.046
0. 000 0.092 0.000 0.046 0.046 0.046 0.000 0.046 0.781 0.735 0.184 0.138 0.000 0.000 0.000
0. 000
0. 000 0.000 2.528 2.757 1.654
1. O11
1. 103 1.792 3.814 4.779 4.550 2.160 2.022 1.517 0.965 0.781
1. 103 1.654 SUBTOTAL 0.000 0.689 2.252 2.574 3.493 10.983 8.778 3.401 2.022 34.191 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 749 744 2176 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED = 12.00 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-127

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F

( 1.5< DELTA T<= 4.0 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.092 0.000 0.000 0.000 0.000 0.138 0.138 0.046 0.000 0.000 0.046 0.000 0.597 0.000 0.092 0.046 0.000 0.000 0.000 0.046 0.046 0.000 0.092 0.092 0.046 0.000 0.046 0.000 0.000 0.506 0.000 0.000 0.046 0.046

0. 000 0.046 0.092 0.138 0.230 0.184 0.138 0.184 0.046 0.000 0.000 0.000 1.149 0.184 0.276
0. 000 0.092
0. 000 0.000 0.368 0.322 0.092 0.138 0.322 0.184 0.138 0.000 0.000 0.000 2.114 0.092 0.276 0.138 0.092 0.000 0.000 0.000 0.046 0.138 0.092 0.000 0.000 0.000 0.000 0.000 0.322 1.195
0. 000 0.092 0.046
0. 000
0. 000
0. 000 0.046
0. 000
0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000 0.000 0.184 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.276 0.735 0.322 0.322 0.092 0.046 0.551 0.551 0.460 0.643 0.689 0.460 0.184 0.046 0.046 0.322 5.744 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WINtD DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 125 125 2176 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =

9.34 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-128

JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

Browns Ferry Nuclear Plant OCT 1, 2002 -

DEC 31, 2002 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4

>=24.5 TOTAL N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW SUBTOTAL

0. 000
0. 000
0. 000 0.000 0.000
0. 000
0. 000
0. 000
0. 000
0. 000 0.000
0. 000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.046 0.046
0. 000 0.000 0.092
0. 000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.046 0.000 0.000
0. 000 0.000 0.000
0. 000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.046 0.092 0.000 0.000 0.000 0.000 0.000 0.138 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.092 0.138
0. 000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000
0. 000 0.000 0.000 0.000
0. 000 0.000 0.184 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0. 000
0. 000 0.138 0.000 0.046 0.092 0.046 0.000 0.000 0.000 0.046 0.046 0.092 0.000 0.046 0.046 0.000 0.000 0.597 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2186 13 13 2176 0

METEOROLOGICAL FACILITY:

Browns Ferry Nuclear Plant STABILITY BASED ON DELTA-T BETWEEN 45.30 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2003/02/07 MEAN WIND SPEED =

9.95 NOTE:

TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-129

ENCLOSURE 3 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JANUARY THROUGH DECEMBER 2002 E3-1

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 Regulatory and BFN ODCM Limits A.

Fission and Activation Gases in Gaseous Effluent:

The release of fission and activation gases is regulated by the dose limits of 10 CFR 50 Appendix I and BFN Offsite Dose Calculation Manual (ODCM). The air dose to areas at and beyond the site boundary due to noble gases released in gaseous effluents per unit, shall be limited during any calendar quarter to < 5 nillirad (mrad) for gamma radiation and < 10 mrad for beta radiation; and during any calendar year to < 10 mrad for gamma radiation and < 20 mrad for beta radiation.

B.

Iodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents.

The release of iodines and particulates in gaseous effluent is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The dose to a member of the public from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives greater than eight days in gaseous effluent released per unit to areas at and beyond the site boundary shall be limited to any organ during any calendar quarter to < 7.5 millirem (mrem), and during any calendar year to < 15 mrem.

C.

Liquid Effluents The release of radioactive liquid effluents is regulated by the dose limits of 10 CFR 50, Appendix I, and the BFN ODCM. The doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas shall be limited during any calendar quarter to < 1.5 mrem to the total body and <5 mrem to any organ and during any calendar year to < 3 mrem to the total body and < 10 mrem to any organ.

II.

Limitation on Dose Rate A.

Fission and Activation Gases in Gaseous Effluent:

1. The instantaneous release rate of fission and activation gases is based on the dose rate limits of 10 CFR 20.1301 and the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary due to noble gases released in gaseous effluents from the site shall be limited to

< 500 mrem per year to the total body and < 3000 mrem per year to the skin.

2. The BFN ODCM Section 7.2 determines the maximum noble gas release rate.

E3-2

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 II.

Limitations on Dose Rate (Continued)

B.

lodines and Particulates with Half-Lives Greater than Eight Days in gaseous effluents.

1.

The instantaneous release rate of particulates and iodines is regulated by the dose rate limits of the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary, due to 1-131, 1-133, H-3 and particulates with greater than eight days half-lives released in gaseous effluents from the site, shall be limited to < 1500 mrem per year to any organ.

2.

The BFN ODCM Section 7.3 determines the maximum particulate and iodine dose rates.

C.

Liquid Effluents

1. The concentration of radionuclides in liquid effluents released at any time from the site to unrestricted areas shall be limited to the concentrations specified in 10 CFR 20.1001 -

20.2402, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases.

2. For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 pCi per milliliter (ml) total activity.
m.

Measurements and Approximations of Total Radioactivity A.

Fission and Activation Gases:

1. Noble gases in the building vent and stack (elevated) gaseous effluents are continuously monitored. The flow rate of the stack is continuously monitored and the building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans. The vent flow is calculated for each release. Gas grab samples of the stack are taken and analyzed weekly. Gas grab samples of in-service vents are taken and analyzed monthly. The specific noble gas activity concentrations and total volume of the gases are used to calculate the total curies of noble gases released.
2. The tritium concentration is determined by the analysis of a monthly grab sample for each release point.

E3-3

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 mII.

Measurements and Approximations of Total Radioactivity (continued)

B.

Iodines and Particulates I.

lodines and particulates are continuously sampled on impregnated charcoal filters and particulate filters, respectively. The charcoal and particulate samples are replaced at least weekly and analyzed to determine specific activity concentrations. The specific activity concentrations and vent flow rate data are used weekly to verify that release rate limits were not exceeded. The specific activity concentrations and total volume of gaseous effluent are used on a monthly basis to determine the total curies of each particulate and iodine released during the month.

2.

The gross alpha concentration is determined by analysis of a monthly particulate filter composite sample and strontium -89 and -90 are determined by analysis of a quarterly particulate filter composite sample for each release point.

C.

Liquid Effluents

1.

The gamma ray emitting radionuclide concentrations are determined for each batch by gamma ray spectroscopy analysis of a grab sample. The allowable release rate is calculated for each batch based upon the known dilution flow. The flow rate of the liquid effluent is continuously monitored and the total volume released in each batch is determined. The total gamma activity released in each batch is determined by multiplying the radionuclide concentrations by the total volume discharged. The total gamma activity released during the month is then determined by summing the gamma activity content of each batch discharged during the month.

2.

The gross alpha and tritium concentrations are measured on a monthly composite sample.

The strontium -89 and -90 and iron -55 are measured on a quarterly composite sample.

D.

The Radioactive Gaseous and Liquid Waste Monitoring Sampling and Analysis Program is specified in ODCM Sections 1/2.2.1 and 1/2.2.2.

E3-4

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION 2002 IV.

Batch Quarter Quarter Quarter Quarter 1

2 3

4 A. Liquid Units 1.

2.

3.

4.

5.

6.

Number of batches released Each Total time for batches released Minutes Maximum time period for a batch release Minutes Average time period for a batch release Minutes Minimum time period for a batch release Minutes Average stream flow during period of release into a flowing stream Cubic feet per second 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 B. Gaseous None C. Abnormal/Unplanned Releases*

Type Liquid Gaseous Number of Releases None None Total Activity Releases (Curies)

None None

  • An explanation of any liquid or gaseous abnorrnal/unexplained release shall be documented in the summary.

E3-5

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES YEAR 2002 Units Quarter Quarter A. Fission and Activation Products (Does not include tritium, gases, Alpha)

1. Total Release
2. Average Diluted Concentration Released During Period
3. Percent of Applicable Limit B. Tritium
1. Total Releases
2. Average Diluted Concentration Released During Period
3. Percent of Applicable Limit C. Dissolved and Entrained Noble Gases
1. Total Releases
2. Average Diluted Concentration Released During Period
3. Percent of Applicable Limit D. Gross Alpha Radioactivity
1. Total Releases
2. Average Diluted Concentration Released During Period E. Volume of Liquid Waste to Discharge Canal (Prior to dilution)

F. Volume of Dilution Water for Period G. Total CCW gil I

2 Curies NR*

liCi/ml NR Curies NR

,uCi/ml NR Curies NR NR NR NR NR NR NR NR NR NR NR NR Quarter 3

NR NR NR NR NR NR NR NR NR NR NR NR NR 6

Quarter Error 4

NR NR 9

NR 8

~tCi/ml NR NR NR 48 NR Curies NR

[+/-Ci/ml Liters Liters igagallons NR NR NR NR NR NR NR 3

10

  • NR - No liquid releases were made in the Ist 2nd 3rd and 4h quarters.
    • The applicable limit is expressed in terms of dose. See Enclosure 1, Tables 5 through 8.

E3-6

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID RELEASES FOR YEAR 2002 - BATCH MODE CURIES Isotope Ouarter Ouarter Quarter Quarter (Required by Regulatory 1

2 3

4 (REG) Guide 1.21)

1.

Ba-140 NR*

NR NR NR

2.

Ce-141 NR NR NR NR

3.

Co-58 NR NR NR NR

4.

Co-60 NR NR NR NR

5.

Cr-51 NR NR NR NR

6.

Cs-134 NR NR NR NR

7.

Cs-137 NR NR NR NR

8.

Fe-59 NR NR NR NR

9.

I-131 NR NR NR NR

10.

La-140 NR NR NR NR

11.

Mn-54 NR NR NR NR

12.

Mo-99 NR NR NR NR

13.

Nb-95 NR NR NR NR

14.

Sr-89 NR NR NR NR

15.

Sr-90 NR NR NR NR

16.

Tc-99m NR NR NR NR

17.

Xe-133 NR NR NR NR

18.

Xe-135 NR NR NR NR

19.

Zn-65 NR NR NR NR

20.

Zr-95 NR NR NR NR Others (Not Required by REG Guide 1.21)

NONE

  • NR -- No liquid releases were made during the 1st 2nd 3rd and 4th quarters E3-7

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES YEAR 2002 Units Quarter 1

A. Fission and Activation Gases

1. Total Releases
2. Average Release Rate for Period
3. Percent of Applicable Limit B. Iodines
1. Total Iodine-131
2. Average Release Rate for Period
3. Percent of Applicable Limit C. Particulates
1. Particulates with half-lives

> eight days

2. Average Release Rate for Period
3. Percent of Applicable Limit
4. Gross Alpha Radioactivity D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Applicable Limit Curies

[iCi/sec Curies tCi/sec Curies utCi/sec Curies Curies Ci/sec 1.59E+01 2.05E+00 4.03E-03 5.18E-04 1.15E-03 1.48E-04 ND**

3.1 OE+0 I 3.99E+00 Quarter 2

6.13E+01 7.79E+00 8.73E-02 1.1 E-02 1.13E-03 1.44E-04 ND 1.32E+01 1.67E+00 Quarter 3

1.20E+03 1.51 E+02 4.588E-03 5.77E-04 1.41E-03 1.78E-04 ND 1.06E+01 1.34E+00 Quarter 4

1.63E+03 2.05E+02 Error 45 1.80E-01 36 2.26E-02 2.42E-03 35 3.05E-04 ND 6.38E+01 21 8.02E+00

  • Applicable Limits are expressed in terms of dose. See Enclosure 1, Tables 1 through 4.
    • ND - Not Detected.

E3-8

EFFLUENT AN CURIES

1. Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Others (specify)

N-13 Total for Period

2.

Iodines 1-131 1-133 Total for Period

  • ND - Not Detected.

D WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - ELEVATED RELEASE Quarter Quarter Quarter 1

2 3

1.59E+01 ND*

ND ND ND ND ND ND ND 1.59E+01 2.44E-04 2.111E-04 4.55E-04 2.59E+00 ND ND ND 5.87E+01 ND ND ND ND 6 12E+01 4.03E-03 4.26E-04 4 46E-03 1.09E+02 ND ND 4.51E+01 1.04E+03 ND 3.65E+00 ND 7.72 E+00 1.20E+03 5.3 1E-04 2.61E-04 7.92E-04 Quarter 4

2.03E+02 ND ND 8.82E+01 1.33E+03 ND 3.63E+00 ND ND I 63E+03 5.42E-03 8.88E-04 6.3 1E-03 E3-9

EFFLUENT AND WASTE DISPOSAL ANNUAL REPOR1 YEAR 2002 GASEOUS EFFLUENTS - ELEVATED RELEASE Quarter Quarter Quarter 1

2 3

CURIES

3.

Particulates*

Sr-89 Sr-90 9.95E-05 ND**

Cs-134 Cs-137 Ba-140 La-140 Others (specify)

Rb-88 Rb-89 Sr-91 Y-91m Cs-138 Ba-139 Au-199 Total for Period*

4.

Tritium ND ND 9.211E-05 4.29E-05 ND 1.061E-01 2.3 SE-04 6.81E-04 2.35E-01 9.52E-02 2.16E-05 4 37E-01 7.27E-01 4.96E-05 ND 2.51E-06 2.05E-06 4.58E-05 1.62E-05 ND 2.21E-02 3.18E-04 5.02E-04 7.66E-02 5.60E-02 ND 1.56E-01 9.62E-01 8.66E-05 ND ND ND 5.13E-05 1.84E-05 ND 1.62E-01 6.21E-05 4.16E-04 2.74E-01 8.56E-02 ND 5.23E-01 1.60E+00 Quarter 4

1. I 9E-04 ND ND ND 7.60E-05 2.32E-05 1.32E-01 3.25E-02 3.65E-04 5.98E-04 9.60E-01 1.21E-01 ND I 25E+00 I 84E+00
  • Includes all nuclides, even those with less than an eight day half-life.
    • ND - Not Detected.

E3-10

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - GROUND RELEASE CURIES Quarter Quarter Quarter Quarter 1

2 3

4

1. Fission Gases Kr-85m ND*

ND ND ND Kr-85 ND ND ND ND Kr-87 ND ND ND ND Kr-88 ND ND ND ND Xe-133 ND ND ND ND Xe-135m ND ND ND ND Xe-135 ND ND ND ND Xe-138 ND ND ND ND Others(specify)

NONE Total for Period ND ND ND ND

2.

lodines 1-131 1.88E-03 2.12E-03 1.O1E-03 9.45E-03 1-132 ND ND ND 2.74E-04 1-133 4.20E-03 9.1 OE-04 1.03E-03 7.111E-03 1-135 ND ND ND 3.48E-04 Total for Period 6.08E-03 3.03E-03 2.04E-03 1.72E-02

  • ND - Not Detected.

E3-11

CURIES

3. Particulates*

Sr-89 Sr-90 Cs-134 Cs-137 Ba-140 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - GROUND RELEASE Quarter Quarter Quarter 1

2 3

4.13E-05 1.45E-07 1.63E-05 ND**

ND ND ND ND ND ND ND ND 6.54E-05 ND ND 1.24E-05 ND ND La-140 Others (specify)

Quarter 4

1.15E-04 ND ND ND 2.47E-05 ND ND ND ND ND 7.11E-04 3.68E-01 3.98E-02 4.08E-01 4.14E+00 Cr-51 ND 4.02E-05 Mn-54 1.22E-06 1.55E-05 Co-60 ND 1.69E-05 Sr-91 1.311E-04 ND Y-91m 1.42E-03 6.71E-06 Cs-138 3.16E-02 1.39E-02 Ba-139 2.71E-02 7.18E-04 Total for Period*

6.04E-02 1.47E-02

4.

Tritium 6.04E+00 2.03E+00

  • Include all nuclides even those with less than an eight day half-life.
    • ND - Not Detected.

ND ND ND ND 6.1lE-05 5.60E-02 8.67E-03 6.47E-02 2 3 1E+00 E3-12

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

CURIES Quarter Quarter Quarter Quarter 1

2 3

4

1.

Fission Gases Kr-85m ND**

ND ND ND Kr-85 ND ND ND ND Kr-87 ND ND ND ND Kr-88 ND ND ND ND Xe-133 ND ND ND 3.86E-02 Xe-135m ND ND ND ND Xe-135 ND ND ND 8.13E-03 Xe-138 ND ND ND ND Others(specify)

NONE Total for Period ND ND ND 4.68E-02

2.

lodines I-131 1.91E-03 8.12E-02 3.04E-03 1.65E-01 I-133 4.29E-03 4.33E-03 4.53E-03 4.65E-02 I-135 1.02E-04 ND ND ND Total for Period 6 30E-03 8 55E-02 7.57E-03 2.111E-01

  • The Reactor Building and Radwaste Building are treated as split-level releases.
    • ND - Not Detected E3-13

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

CURIES Quarter Quarter Quarter Quarter 1

2 3

4

3.

Particulates**

Sr-89 7.82E-05 3.35E-05 3.29E-05 8.82E-05 Sr-90 ND***

ND ND ND Cs-134 ND 1.12E-04 2.21E-04 4.60E-04 Cs-137 4.13E-06 1.70E-04 4.90E-04 7.90E-04 Ba-140 3.1 lE-04 7.85E-05 8.97E-05 2.54E-04 La-140 2.16E-04 1.14E-05 4.97E-05 7.87E-05 Others (specify)

Na-24 2.06E-04 2.36E-03 2.89E-03 1.34E-03 Cr-51 2.08E-04 1.52E-04 ND ND Mn-54 6.68E-05 1.21E-04 1.18E-04 1.05E-04 Co-58 1.18E-05 4.15E-05 6.76E-05 2.53E-05 Fe-59 1.48E-05 2.65E-06 ND ND Co-60 9.OOE-05 1.89E-04 1.12E-04 1.23E-04 Zn-65 ND 3.36E-05 5.40E-05 1.06E-04 Y-9lm 2.93E-03 1.17E-03 2.50E-03 3.06E-03 Sr-91 2.96E-03 ND 2.53E-04 2.01E-03 Sr -92 2.47E-04 ND ND ND

  • The Reactor Building and Radwaste Building are treated as split-level releases.
    • Includes all nuclides, even those with less than an eight day half-life.
      • ND - Not Detected.

E3-14

EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT YEAR 2002 GASEOUS EFFLUENTS - MIXED MODE RELEASE*

CURIES Particulates** (Continued)

Others (specify)

Quarter I

Quarter 2

Ouarter 3

Mo-99 Tc-99m Ag-1Orm 5.53E-06 5.40E-06 3.86E-05 5.20E-03 6.63E-02 ND Cs-138 ND 2.OOE-05 ND 2.50E-02 1.54E-06 ND***

2.96E-05 Ba-139 2.89E-05 6.73E-05 ND 5.19E-03 ND 1.22E-02 Quarter 4

3.01E-05 2.94E-05 1.33E-04 2.26E-02 8.51E-02 ND 1.1 6E-01 Au-I99 Total for Period**

7.90E-02 2.95E-02

4.

Tritium 2.42E+01 1.02E+01 6.70E+00 5.78E+01

  • The Reactor Building and Radwaste Building are treated as split-level releases.
    • Includes all nuclides, even those with less than an eight day half-life.
      • ND - Not Detected.

E3-15

BROWNS FERRY NUCLEAR PLANT ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 2002 SOLID WASTE AND IRRADIATED FUEL A.

Solid Waste Shipped Off-site for Burial or Disposal (Not Irradiated Fuel)

1.

Type of Waste

a.

Spent resins, filter sludge evaporator bottoms, etc.

Units m3 ci Amount 0.00E+00 0.00E+00 1.71 E+02 6.47E+01 Error %

+/-25.0

b.

Dry compressible waste, contaminated m3 equipment, etc.

Ci

c.

Irradiated components, control rod drives m3 ci 0.OOE+00 0.OOE+00

d.

Cartridge filters m3 0.OOE+00 Ci 0.OOE+00

2. Estimate of Major Nuclide Composition by Waste Type
a.

Dry compressible waste, Nuclide

1. Iron55 (1)
2.

Cobalt60 (1)

3. Manganese5 4 (1)
4. Silver11 0m (1)
5. Cesium1 37 (1)
6. Chromium51 (1)
7. Iron59 (1)
8. Zinc6 5 (1)
9. Cesium1 34 (1)
10. Cobalt58 (1)
11. Nickel63 (1)
12. Antimony 124 (1)
13. Antimony125 (1)
14. Zirconium95 (1)
15. Cerium 14 4 (1)
16. Strontium89 (1)
17. Tin113 (1)
18. Strontium90 (1)
19. Curium2 43/244 (1) contaminated equipment, etc.

Percentage 7.62E+01 9.54E+00 7.1 OE+00 2.06E+00 1.24E+00 9.76E-01 8.85E-01 7.45E-01 3.91 E-01 3.27E-01 1.96E-01 1.19E-01 8.95E-02 6.96E-02 3.98E-02 1.99E-02 9.95E-03 3.71 E-05 3.09E-06 Activity (Curies) 4.98E+01 6.17E+01 4.60E+00 1.34E+00 8.05E-01 6.32E-01 7.73E-01 4.82E-01 2.53E-01 2.12E-01 1.27E-01 7.72E-02 5.79E-02 4.51 E-02 2.57E-02 1.29E-02 6.44E-03 2.40E-05 2.OOE-06 (1) Calculated E3-16

BROWNS FERRY NUCLEAR PLANT ANNUAL EFFLUENT AND WASTE DISPOSAL REPORT 2002 SOLID WASTE AND IRRADIATED FUEL

3. Solid Waste Disposition Number of Shipments 1

Mode of Transportation (1) Non Sole Use Truck Destination US Ecology Oak Ridge, TN 42 1

(24) Sole Use Truck (18) Non Sole Use Truck (1) Non Sole Use Truck Duratek Oak Ridge, TN Tennessee Valley Authority Mixed Waste Storage Facility Muscle Shoals, AL B.

Irradiated Fuel Disposition Number of Shipments None Mode of Transportation N/A Destination N/A C.

Description of Shipments Number of Shipments 44 Type Container Strong Tight Package Type Quantity A-LSA II LTD QTY Number of Containers 52 Container Volume See Note Waste Type DAW Solidification Agents Used:

Absorbents Used:

None None NOTE: The 44 shipments of waste packaged in strong tight packages consisted of the following:

Type of STC 40' "Sealand" 20'"Sealand" 55 Gal drum Number of Packages 30 21 1

Volume of Packages (i 3 )

2.31 E+03 7.64E+02 2.12E-01 E3-17

BROWNS FERRY NUCLEAR PLANT EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT

SUMMARY

OF ABNORMAL/UNPLANNED RELEASES 2002 The release of radioactive material to the environment from Browns Ferry has been a small fraction of the 10 CFR 20 Appendix B and 10 CFR 50 Appendix I limits. There were no limits exceeded as specified in 10 CFR2OAppendixB and 10 CFR5OAppendixI.

No abnormal gaseous or liquid releases occurred in 2002.

During the reporting period, January I through December 31, 2002, there was no missed compensatory measures.

In calendar year 2002 Browns Ferry had no changes to the radwaste system or the Process Control Program (PCP).

E3-18

ENCLOSURE 4 TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 INOPERABLE RADIOLOGICAL EFFLUENT INSTRUMENTATION REPORT JANUARY THROUGH DECEMBER 2002 E4-1

INOPERABLE RADIOLOGICAL EFFLUENT INSTRUMENTATION REPORT 2002 This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (Offsite Dose Calculation Manual (ODCM)) Sections 1/2.1.1 and 1/2.1.2. The ODCM requires the exertion of best efforts to return inoperable instruments to operable status within 30 days. Failure to return such instruments to an operable status within the prescribed interval requires a description in the Annual Radioactive Effluent Release Report.

During the reporting period, January I through December 31, 2002, there were no radioactive gaseous effluent monitoring instrumentation out of service for greater than 30 days; however, one liquid effluent monitor was out of service for greater than 30 days. The Unit I RHR service water monitor (1-RM-90-134) was considered inoperable between the times of December 08, 2001, at 0045 hours5.208333e-4 days <br />0.0125 hours <br />7.440476e-5 weeks <br />1.71225e-5 months <br /> through January 7, 2002 at 1207 hours0.014 days <br />0.335 hours <br />0.002 weeks <br />4.592635e-4 months <br />. The monitor had tripped due to low flow conditions. Work Orders were initiated in a timely manner and work packages were planned for implementation based on a priority status of not exceeding 21 days. Initial troubleshooting of the flow problem was completed on 12-29-2001 and had resolved the flow problem. However, during post maintenance testing activities, it was determined that a wiring error existed with a hand-switch in the pump start logic. A second work order was prepared to troubleshoot the wiring problem and was successfully completed on 01-07-2003. The monitor was then returned to service having exceeded 30 days by a few hours.

Some effluent monitors and flow instrumentation were placed in "out-of-service" status because these monitors' effluent streams were isolated. Therefore, these monitors are not included in this report.

E4-2