ODCM APPENDIX COLUMBIA GENERATING STATION Radiological Effluent And Radiological Environmental Monitoring Controls
OFFSITE DOSE CALCULATION MANUAL APPENDIX LIST OF EFFECTIVE PAGES AMEND.
NO.
35 35 PAGE i
ii 6.0-1 6.0.1-1 6.0.1-2 6.0.1-3 6.1.1-1 6.1.1-2 6.1.1-3 6.1.1-4 6.1.2-1 6.1.2-2 6.1.2-3 6.1.2-4 6.1.2-5 6.1.2-6 6.1.2-7 AMEND.
NO.
35 35 35 35 35 35 35 35 35 37 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 Amendment 37, January 2003 PAGE 6.2.2.4-1 6.2.2.4-2 6.2.2.5-1 6.2.2.5-2 6.2.2.6-1 6.2.2.6-2 6.2.3-1 6.2.3-2 6.2.3-3 6.3.1-1 6.3.1-2 6.3.1-3 6.3.1-4 6.3.1-5 6.3.1-6 6.3.1-7 6.3.1-8 6.3.1-9 6.3.1-10 6.3.1-11 6.3.1-12 6.3.1-13 6.3.2-1 6.3.2-2 6.3.3-1 6.4.1-1 6.4.2-1 6.4.2-2 6.4.3-1 6.4.3-2 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 6.2.1.1-1 6.2.1.1-2 6.2.1.1-3 6.2.1.2-1 6.2.1.2-2 6.2.1.3-1 6.2.1.3-2 6.2.2.1-1 6.2.2.1-2 6.2.2.1-3 6.2.2.1-4 6.2.2.1-5 6.2.2.1-6 6.2.2.1-7 6.2.2.2-1 6.2.2.2-2 6.2.2.3-1 6.2.2.3-2 ODCM LEP-1
OFFSITE DOSE CALCULATION MANUAL APPENDIX LIST OF EFFECTIVE PAGES PAGE AMEND.
NO.
35 36 36 37 36 36 36 36 6.1.1-1 6.1.1-2 6.1.1-3 6.1.1-4 6.1.1-5 6.1.1-6 6.1.1-7 6.1.1-8 6.1.2-1 6.1.2-2 6.1.2-3 6.1.2-4 6.1.2-5 6.1.2-6 6.1.2-7 6.1.2-8 6.1.2-9 6.1.2-10 6.1.2-11 6.1.2-12 6.1.2-13 6.1.2-14 6.2.1.1-1 6.2.1.1-2 6.2.1.1-3 6.2.1.1-4 6.2.1.2-1 6.2.1.2-2 6.2.1.2-3 6.2.1.3-1 6.2.1.3-2 6.2.1.3-3 6.2.2.1-1 6.2.2.1-2 6.2.2.1-3 6.2.2.1-4 6.2.2.1-5 6.2.2.1-6 6.2.2.1-7 6.2.2.1-8 6.2.2.1-9 B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B B
B 6.2.2.2-1 6.2.2.2-2 6.2.2.2-3 6.2.2.3-1 6.2.2.3-2 6.2.2.3-3 6.2.2.4-1 6.2.2.4-2 6.2.2.4-3 6.2.2.5-1 6.2.2.5-2 6.2.2.5-3 6.2.2.6-1 6.2.2.6-2 6.2.2.6-3 6.2.3-1 6.2.3-2 6.2.3-3 6.3.1-1 6.3.1-2 6.3.1-3 6.3.1-4 6.3.1-5 6.3.1-6 6.3.1-7 6.3.2-1 6.3.2-2 6.3.2-3 B 6.3.3-1 35 B 6.3.3-2 35 35 35 35 35 35 35 35 PAGE Amendment 37, January 2003 AMEND.
NO.
35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 ODCM LEP-2
OFFSITE DOSE CALCULATION MANUAL APPENDIX TABLE OF CONTENTS RADIOLOGICAL EFFLUENT AND RADIOLOGICAL ENVIRONMENTAL MONITORING CONTROLS
6.0 INTRODUCTION
6.0.1 DEFINITIONS 6.1 INSTRUMENTATION 6.1.1 Radioactive Liquid Effluent Monitoring Instrumentation 6.1.2 Radioactive Gaseous Effluent Monitoring Instrumentation 6.2 6.2.1 6.2.1.1 6.2.1.2 6.2.1.3 6.2.2 6.2.2.1 6.2.2.2 6.2.2.3 6.2.2.4 6.2.2.5 6.2.2.6 6.2.3 6.3 6.3.1 6.3.2 6.3.3 6.4 6.4.1 6.4.2 6.4.3 S..
6.0-1 6.0.1-1 6.1.1-1 6.1.2-1 RADIOACTIVE EFFLUENTS Liquid Effluents.............
6.2.1.1-1 Liquid Concentration...........
6.2.1.1-1 Liquid Dose..............
6.2.1.2-1 Liquid Waste Management System.......
6.2.1.3-1 Gaseous Effluents............
6.2.2.1-1 Dose Rate..............
6.2.2.1-1 Dose - Noble Gases...............................
6.2.2.2-1 Dose - 131.
133, Tritium, and Radionuclides in Particulate Form.......
6.2.2.3-1 Gaseous Offgas Treatment System....
6.2.2.4-1 Reactor Building Sump Vent Exhaust Filter System 6.2.2.5-1 VENTING or PURGING.........
6.2.2.6-1 Total Dose................
6.2.3-1 RADIOLOGICAL ENVIRONMENTAL MONITORING Radiological Environmental Monitoring Program 6.3.1-1 Land Use Census..........
6.3.2-1 Interlaboratoiy,omparison Program........
6.3.3-1 REPORTING REOUIREMENTS Annual Radiological Environmental Operating Report 6.4.1-1 Radioactive Effluent Release Report.......
6.4.2-1 Major Changes to Radioactive Liquid, Gaseous, and Solid Waste Treatment Systems.......
6.4.3-1 Columbia Generating Station Amendment 35, MAR 2002 i
OFFSITE DOSE CALCULATION MANUAL APPENDIX BASES BASES FOR RADIOLOGICAL EFFLUENT AND RADIOLOGICAL ENVIRONMENTAL MONITORING CONTROLS INSTRUMENTATION Radioactive Liquid Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation RADIOACTIVE EFFLUENTS Liquid Concentration Liquid Dose Liquid Waste Management System Dose Rate Dose - Noble Gases Dose - 131, 133, Tritium, and Radionuclides in Particulate Form Gaseous Offgas Treatment System Reactor Building Sump Vent Exhaust Filter System VENTING or PURGING Total Dose RADIOLOGICAL ENVIRONMENTAL MONITORING Radiological Environmental Monitoring Program Land Use Census Interlaboratory Comparison Program B 6.1.1-1 B 6.1.2-1 B
B B
B B
B B
B B
6.2.1.1-1 6.2.1.2-1 6.2.1.3-1 6.2.2.1-1 6.2.2.2-1 6.2.2.3-1 6.2.2.4-1 6.2.2.5-1 6.2.2.6-1 B 6.2.3-1 B 6.3.1-1 B 6.3.2-1 B 6.3.3-1 Columbia Generating Station B 6.1 B 6.1.1 B 6.1.2 6.2 6.2.1.1 6.2.1.2 6.2.1.3 6.2.2.1 6.2.2.2 6.2.2.3 6.2.2.4 6.2.2.5 6.2.2.6 6.2.3 6.3 6.3.1 6.3.2 6.3.3 ii Amendment 35, MAR 2002
Introduction 6.0 Introduction
6.0 INTRODUCTION
The Columbia Generating Station Off-Site Dose Calculation Manual (ODCM)
Appendix contains the Radiological Effluent and Radiological Environmental Monitoring Controls required by Technical Specification 5.5.1.b.
These controls are written in the format of the Columbia Generating Station Licensee Controlled Specifications (LCS) to provide a consistent set of requirements for the station.
The definitions contained in the Technical Specifics and the LCS apply to this Appendix.
In addition, Section 1.0 of the LCS that gives the Requirements for OPERABILITY (RFO)
Applicability (RFOs 1.0.1 through 1.0.6) and Surveillance Requirement (SR)
Applicability (SR 1.0.1 through SR 1.0.4) also apply to all RFOs and SRs in this Appendix.
Columbia Generating Station 6.0-1 Amendment 35, MAR 2002
Definitions 6.0.1 6.0.1 Definitions The following definitions and definitions of Technical Specifications and Licensee Controlled Specifications apply to the Appendix of the ODCM.
They are defined so that uniform interpretation of these requirements for OPERABILITY may be achieved.
The defined terms appear in capitalized type and shall be applicable throughout the ODCM.
Term DEFINITIONS GASEOUS OFFGAS TREATMENT SYSTEM LOWER LIMIT OF DETECTION (LLD)
A GASEOUS OFFGAS TREATMENT SYSTEM (e.g., the "augmented offgas system") is any system designed and installed to reduce radioactive gaseous effluents by collecting primary coolant system offgases from the main condenser evacuation system and providing for delay or holdup for the purpose of reducing the total radioactivity prior to release to the environment.
The LLD is defined, for purposes of this ODCM Specification, as the smallest concentration of radioactive material in a sample that will yield a net count above system background that will be detected with 95% probability with only 5% probability of falsely concluding that a blank observation represents a "real" signal.
For a particular measurement system which may include radiochemical separation:
LLD =
4.66 Sb E - V o 222 x10 6
- Y ° exp (-XA-t)
Where:
LLD is the "a priori" lower limit of detection as defined above as microcuries per unit mass or volume.
Sb is the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate as counts per minute.
E is the counting efficiency as counts per disintegration.
V is the sample size in units of mass or volume.
(continued)
Columbia Generating Station 6.0.1-1 Amendment 35, MAR 2002
Definitions 6.0.1 6.0.1 Definitions LOWER LIMIT OF DETECTION (LLD)
(continued)
MEMBER(S)
OF THE PUBLIC OPERATIONAL CONDITION CONDITION PURGE - PURGING SITE BOUNDARY 2.22 x 106 is the number of disintegrations per minute per microcurie.
Y is the fractional radiochemical yield when applicable.
X is the radioactive decay constant for the particular radionuclides and AT for plant effluents is the lapsed time between the midpoint of sample collection and time of counting.
Typical values of E, V, Y, and Atshould be used in the calculation.
It should be recognized that the LLD is defined as an a priori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (afer the fact) limit for a particular measurement.
MEMBERS OF THE PUBLIC shall include all persons who are not occupationally associated with the plant.
This category does not include employees of the utility, its contractors or vendors.
Also excluded from this category are persons who enter the site to service equipment or to make deliveries.
This category does include persons who use portions of the site for recreational, occupational or other purposes not associated with the plant.
See Technical Specification definition of MODE.
PURGE PURGING shall be the controlled process of discharging air or gas from a containment to maintain temperature, pressure, humidity, concentration or other operating condition, in such a manner that replacement air or gas is required to purify the containment.
The SITE BOUNDARY shall be as generally depicted in
- ODCM, Figure 3-1.
The SITE BOUNDARY shall be that line beyond which the land is neither owned, nor leased, nor otherwise controlled by the licensee.
(continued)
Columbia Generating Station 6.0.1-2 Amendment 35, MAR 2002
Definitions 6.0.1 6.0.1 Definitions (continued)
SOURCE CHECK UNRESTRICTED AREA VENTILATION EXHAUST TREATMENT SYSTEM VENTING A SOURCE CHECK shall be the qualitative assessment of channel response when the channel sensor is exposed to a radioactive source.
An UNRESTRICTED AREA shall be any area at or beyond the SITE BOUNDARY access which is not controlled by the licensee for purposes of protection of individuals from exposure to radiation and radioactive materials, or any area within the site boundary used for residential quarters or for industrial, commercial, institutional, and/or recreational purposes.
A VENTILATION EXHAUST TREATMENT SYSTEM shall be any system designed and installed to reduce gaseous radioiodine or radioactive material in particulate form in effluents by passing ventilation or vent exhaust gases through charcoal adsorbers and/or HEPA filters for the purpose of removing iodines or particulates from the gaseous exhaust stream prior to the release to the environment.
Such a system is not considered to have any effect on noble gas effluents.
Engineered Safety Features Atmospheric Cleanup Systems are not considered to be VENTILATION EXHAUST TREATMENT SYSTEM components.
At Columbia Generating Station the "Reactor Building Sump Vent Exhaust Filter System" is the only VENTILATION EXHAUST TREATMENT SYSTEM.
VE!NTP'3 shall be the controlled process of discharging air gr jas from a containment to maintain temperature, pressure, humidity, concentration, or other operating co,:rliion, in such a manner that replacement air or gas is not provided or required during VENTING.
- Vent, used in system names, does not imply a VENTING process.
Columbia Generating Station Amendment 35, MAR 2002 6.0.1-3
Radioactive Liquid Effluent Monitoring Instrumentation 6.1.1 6.1 INSTRUMENTATION 6.1.1 Radioactive Liquid Effluent Monitoring Instrumentation RFO 6.1.1.1 APPLICABILITY:
The radioactive liquid effluent monitoring instrumentation channels in Table 6.1.1-1 shall be OPERABLE.
In accordance with Table 6.1.1-1.
COMPENSATORY MEASURES
NOTE --------------------------------------
Separate condition entry is allowed for each channel.
CONDITION REOUIRED COMPENSATORY MEASURE COMPLETION TIME A.
One or more required A.1 Enter the condition Immediately radioactive liquid referenced in effluent monitoring Table 6.1.1-1 for the instrumentation channel.
channels inoperable.
B.
As required by B.1 Perform SR 6.2.1.1.1 on Prior to Compensatory Measure two independent samples radioactive A.1 and referenced in of the batch to be liquid release Table 6.1.1-1.
released.
through the radwaste AND effluent line B.2 Verify the associated Prior to release rate radioactive calculations and the liquid release discharge valve lineup through the using two qualified radwaste members of the technical effluent line staff.
AND (continued)
Columbia Generating Station 6.1.1-1 Amendment 35, MAR 2002
Radioactive Liquid Effluent Monitoring Instrumentation 6.1.1 COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME B.
(continued)
B.3 Restore the channel to 30 days OPERABLE status.
C.
As required by C.1 Analyze a grab sample Once per 12 Compensatory Measure for radioactivity (beta hours A.1 and referenced in or gamma) of the Table 6.1.1-1.
associated pathway.
The LLD shall be < 1E-7 ACi/ml.
AND C.2 Restore the channel to 30 days OPERABLE status.
D.
As required by D.1 Estimate the flow rate At the beginning Compensatory Measure through the associated of the release A.1 and referenced in pathway.
and once per 4 Table 6.1.1-1.
hours during releases through the associated line AND D.2 Restore the channel to 30 days OPERABLE status.
E.
Required Compensatory E.1 Prepare and submit, in Upon submittal Measure B.3, C.2, or the Radioactive Effluent of current D.2 and associated Release Report, the calendar year Completion Time not reason the channel was Radioactive met.
not restored to OPERABLE Effluent Release status within 30 days.
Report Columbia Generating Station 6.1.1-2 Amendment 35, MAR 2002
Radioactive Liquid Effluent Monitoring Instrumentation 6.1.1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.1.1.1 Perform CHANNEL CHECK.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> SR 6.1.1.2 Perform SOURCE CHECK.
Prior to each radioactive release SR 6.1.1.3 Perform SOURCE CHECK.
31 days SR 6.1.1.4 Perform CHANNEL FUNCTIONAL TEST.
92 days SR 6.1.1.5 Perform CHANNEL CALIBRATION.
18 months Columbia Generating Station Amendment 35, MAR 2002 6.1.1-3
Radioactive Liquid Effluent Monitoring Instrumentation 6.1.1 Table 6.1.1-1 Radioactive Liquid Effluent Monitoring Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM ALARM/
SPECIFIED PER COMPENSATORY SURVEILLANCE TRIP FUNCTION CONDITIONS FUNCTION MEASURE A.1 REQUIREMENTS SETPOINT
- 1. Liquid Radwaste Effluent Line (a) 1 B
SR 6.1.1.1 (b)
Gross Radioactivity Monitor SR 6.1.1.2 SR 6.1.1.4 SR 6.1.1.5
- 2. Deleted
- 3. Turbine Service Water System (d) 1 C
SR 6.1.1.1 BE-6 Gross Radioactivity Monitor SR 6.1.1.3 pCi/ml SR 6.1.1.4 Cs-137 SR 6.1.1.5
- 4. Standby Service Water Gross (d) 1 per C
SR 6.1.1.1 8E-6 Radioactivity Monitor loop SR 6.1.1.3 UCi/ml SR 6.1.1.4 Cs-137 SR 6.1.1.5
- 5. Liquid Radwaste Effluent Line (a) 1 D
SR 6.1.1.1 (c)
Flow Rate Monitor SR 6.1.1.4 SR 6.1.1.5
- 6. Plant Discharge Blowdown Line (a) 1 D
SR 6.1.1.1 (c)
Flow Rate Monitor SR 6.1.1.4 SR 6.1.1.5 (a)
When radioactive effluents are being discharged through this pathway.
(b)
The alarm/trip setpoint of the Liquid Radwaste Effluent Line Gross Radioactivity Monitor shall be set to ensure the limits of RFO 6.2.1.1 are not exceeded for each batch of radioactive liquid effluent released.
The alarm/trip setpoint of this channel shall be determined and adjusted in accordance with the methodology and parameters described in the ODCM and plant procedures.
(c)
No alarm setpoints are required for these record only instruments.
(d)
When there is flow in the system identified by this function.
Columbia Generating Station I
6.1.1-4 Amendment 37, January 2003
Radioactive Gaseous Effluent Monitoring Instrumentation 6.1.2 6.1 INSTRUMENTATION 6.1.2 Radioactive Gaseous Effluent Monitoring Instrumentation RFO 6.1.2.1 APPLICABILITY:
The radioactive gaseous effluent monitoring instrumentation channels in Table 6.1.2-1 shall be OPERABLE.
In accordance with Table 6.1.2-1.
COMPENSATORY MEASURES
NOTE --------------------------------------
Separate condition entry is allowed for each channel.
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
One or more required A.1 Enter the condition Immediately channels inoperable, referenced in Table 6.1.2-1 for the channel.
B.
As required by B.1 Verify the Reactor Immediately Compensatory Measure Building Elevated A.1 and referenced ir Discharge Radiation Table 6.1.2-1.
Monitor is OPERABLE.
OR B.2 Verify the Condition C Immediately Compensatory Actions are being met.
(continued)
Amendment 35, MAR 2002 Columbia Generating Station 6.1.2-1
Radioactive Gaseous Effluent Monitoring Instrumentation 6.1.2 COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME C.
As required by C.1 Take a noble gas grab 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Compensatory Measure sample at the associated A.1 and referenced in sample location.
AND Table 6.1.2-1.
once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter AND C.2 Analyze the grab sample 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after for gamma emmiters as completion of required by Required Required Compensatory Measure Compensatory C.1.
Measure C.1 AND 30 days C.3 Restore the channel to OPERABLE status.
D.
As required by D.1 Estimate the flow rate 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Compensatory Measure through the associated A.1 and referenced in pathway.
AND Table 6.1.2-1.
Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> thereafter AND D.2 Restore the channel to 30 days OPERABLE status.
(continued)
Columbia Generating Station 6.1.2-2 Amendment 35, MAR 2002
Radioactive Gaseous Effluent Monitoring Instrumentation 6.1.2 COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME E.
As required by E.1 Establish auxiliary 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Compensatory Measure sampling equipment to A.1 and referenced in continuously collect AND Table 6.1.2-1.
samples from the associated effluent Continuously release pathway as thereafter required in Table 6.2.2.1-1.
OR E.2 Collect relevant Immediately information to provide an estimate of effluent releases.
AND E.3 Restore the channel to 30 days OPERABLE status.
F.
Required Compensatory F.1 Prepare and submit, in Upon submittal Measure C.3, D.2, or the Radioactive Effluent of current E.3 and associated Release Report, the calendar year Completion Time not reason the channel was Radioactive met or Compensatory not restored to OPERABLE Effluent Release Measure E.2 status within the Report performed.
required completion time or the use of Compensatory Measure E.2.
(continued)
Columbia Generating Station 6.1.2-3 Amendment 35, MAR 2002
Radioactive Gaseous Effluent Monitoring Instrumentation 6.1.2 COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME G.
As required by G.1 Verify the Offgas Immediately Compensatory Measure Treatment System A.1 and referenced (RECHAR) is not in Table 6.1.2-1.
bypassed.
AND G.2 Install a temporary In 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> portable Area Radiation Monitor and record AND radiation levels.
Every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> thereafter AND G.3 Restore the channel to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> OPERABLE status.
H.
Required Compensatory H.1 Be in MODE 2.
12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Measure and associated Completion Time of Condition G not met.
SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.1.2.1 Perform CHANNEL CHECK.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> SR 6.1.2.2 Perform SOURCE CHECK.
24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (continued)
Columbia Generating Station Amendment 35, MAR 2002 6.1.2-4
Radioactive Gaseous Effluent Monitoring Instrumentation 6.1.2 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.1.2.3 Perform CHANNEL CHECK.
7 days SR 6.1.2.4 Perform SOURCE CHECK.
31 days SR 6.1.2.5 Perform CHANNEL FUNCTIONAL TEST.
92 days SR 6.1.2.5a Perform CHANNEL CHECK.
Prior to mechanical vacuum pump use SR 6.1.2.6 Perform CHANNEL CALIBRATION.
18 months SR 6.1.2.7 Perform CHANNEL CALIBRATION.
Each refueling outage Columbia Generating Station 6.1.2-5 Amendment 35, MAR 2002
Radioactive Gaseous Effluent Monitoring Instrumentation 6.1.2 Radioactive Table 6.1.2-1 (page I of 2)
Gaseous Effluent Monitoring Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM ALARM/
SPECIFIED PER COMPENSATORY SURVEILLANCE TRIP FUNCTION CONDITIONS FUNCTION MEASURE A.1 REQUIREMENTS SETPOINT
- 1. Main Condenser Offgas Post-(a) 1 C
SR 6.1.2.1 (c)
Treatment Radiation Monitor SR 6.1.2.2 SR 6.1.2.5 SR 6.1.2.6
- 2.
Main Condenser Offgas Pre-(a) 1 G
SR 6.1.2.1 1.5 Treatment Radiation Monitor SR 6.1.2.4 times SR 6.1.2.5 steady SR 6.1.2.6 state full power 2a. Mechanical Vacuum Pump Discharge (f) 1 B
SR 6.1.2.5a (c)
Radiation Monitor SR 6.1.2.7
- 3.
Reactor Building Elevated Discharge Radiation Monitor (b) a)
Low Range Activity Monitor (e) 1 C
SR 6.1.2.1 (c)
SR 6.1.2.4 SR 6.1.2.5 SR 6.1.2.6 b)
Iodine Sampler (e) 1 E
SR 6.1.2.3 N/A c)
Particulate Sampler (e) 1 E
SR 6.1.2.3 N/A d)
Effluent System Flow Rate (e) 1 D
SR 6.1.2.1 (d)
Monitor SR 6.1.2.5 SR 6.1.2.6 e)
Sampler Flow Rate Monitor (e) 1 D
SR 6.1.2.1 (d)
SR 6.1.2.5 SR 6.1.2.6 (continued)
(a)
When an Offgas Steam Jet Air Ejector is operating.
(b)
When building exhaust is secured collect building ambient air samples and other data to characterize building out-leakage.
(c)
Alarm/trip setpoints shall be determined in accordance with OCDM methodology and set to ensure the limits of RFO 6.2.2.1. Dose Rate-Gaseous Effluents are not exceeded.
(d)
Alarm/trip setpoints shall be determined in accordance with the associated instrumentation specifications and set to ensure a representative sample is obtained.
(e)
During building exhaust system operation.
(f)
During startup and shutdown when vacuum is being maintained with a Mechanical Vacuum Pump and the Steam Seal System is operational.
Columbia Generating Statlon Amendment 35, MAR 2002 6.1.2-6
Radioactive Gaseous Effluent Monitoring Instrumentation 6.1.2 Table 6.1.2-1 (page 2 of 2)
Radioactive Gaseous Effluent Monitoring Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM ALARM/
SPECIFIED PER COMPENSATORY SURVEILLANCE TRIP FUNCTION CONDITIONS FUNCTION MEASURE A.1 REQUIREMENTS SETPOINT
- 4. Turbine Building Ventilation Exhaust Radiation Monitor (b) a)
Noble Gas Activity Monitor Low Range b)
Iodine Sampler c)
Particulate Sampler d)
Effluent System Flow Rate Monitor e)
Sampler Flow Rate Monitor
- 5. Radwaste Building Ventilation Exhaust Radiation Monitor (b) a)
Noble Gas Activity Monitor Low Range b)
Iodine Sampler c)
Particulate Sampler d)
Effluent System Flow Rate Monitor e)
Sampler Flow Rate Monitor (e)
(e)
(e)
(e)
(e)
(e)
(e)
(e)
(e)
(e) 1 1
1 1
1 SR SR SR SR C
E E
D D
6.1.2.1 6.1.2.4 6.1.2.5 6.1.2.6 SR 6.1.2.3 SR 6.1.2.3 SR SR SR SR SR SR C
E E
D D
SR SR SR SR 6.1.2.1 6.1.2.5 6.1.2.6 6.1.2.1 6.1.2.5 6.1.2.6 6.1.2.1 6.1.2.4 6.1.2.5 6.1.2.6 SR 6.1.2.3 SR 6.1.2.3 SR 6.1.2.1 SR 6.2.1.5 SR 6.1.2.6 SR SR SR 6.1.2.1 6.1.2.5 6.1.2.6 (c)
N/A N/A (d)
(d)
(c)
N/A N/A (d)
(d)
(b)
When building exhaust is secured collect building ambient air samples and other data to characterize building out-leakage..
(c)
Alarm/trip setpoints shall be determined in accordance with OCDM methodology and set to ensure the limits of RFO 6.2.2.1. Dose Rate-Gaseous Effluents are not exceeded..
(d)
Alarm/trip setpoints shall be determined in accordance with the associated instrumentation specifications and set to ensure a representative sample is obtained..
(e)
During building exhaust system operation.
Columbia Generating Station 1
Amendment 35, MAR 2002 6.1.2-7
Liquid Concentration 6.2.1.1 6.2 RADIOACTIVE EFFLUENTS 6.2.1 Liquid Effluents 6.2.1.1 Liquid Concentration RFO 6.2.1.1 APPLICABILITY:
The concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS (see Figure 3-1) shall be limited to:
- a.
Ten times the concentration specified in Table 2, Column 2 of Appendix B to 10 CFR Part 20 for radionuclides other than dissolved or entrained noble gases; and
- b.
2 X lO' 4gCi/ml total activity concentration for all dissolved or entrained noble gases.
At all times.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Concentration of A.1 Initiate action to Immediately radioactive material restore concentration to released to within limits.
UNRESTRICTED AREAS not within limits.
Columbia Generating Station Amendment 35, MAR 2002 6.2.1.1-1
Liquid Concentration 6.2.1.1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.2.1.1.1 The radioactivity content of each batch Prior to each of radioactive liquid waste shall be batch release determined prior to release by sampling and analysis in accordance with Table 6.2.1.1-1.
The results of pre-release analyses shall be used with the calculational methods in the ODCM to assure that the concentration at the point of release is maintained within the limits of RFO 6.2.1.1.
SR 6.2.1.1.2 Post-release analysis of samples In accordance composited from batch releases shall be with Table performed in accordance with Table 6.2.1.1-1 6.2.1.1-1.
The results of the post release analyses shall be used with the calculational methods in the ODCM to assure that the concentrations at the point of release were maintained within the limits of RFO 6.2.1.1.
Columbia Generating Station 6.2.1.1-2 Amendment 35, MAR 2002
Liquid Concentration 6.2.1.1 Radioactive Liquid Table 6.2.1.1-1 Waste Sampling a nd Analysis Program MINIMUM SAMPLE LOWER SAMPLE TYPE OF LIMIT OF LIQUID RELEASE SAMPLE ANALYSIS ACTIVITY DETECTION TYPE FREQUENCY FREQUENCY ANALYSIS (LLD)
Batch waste tank release Prior to release of each batch Prior to release of each batch Principal Gamma Emitters 1-131 Dissolved and entrained gases (gamma emitters)
Batch waste tank release Prior to release of each batch Gross Alpha Batch waste tank release Prior to release of each batch Columbia Generating Station 5 X 10-7 yCi /ml 1 X 10-6 pCi /ml 1 X 10-5 pCi/ml 31 days composite Trl ti um 92 days composite Fe-55 1 x 10-5 pCi /ml 1 X 10-7 yCi /ml 1 X 10-6 pCi/ml 5 X I0-8 yCi /ml 5 X 10- 8 pCi /ml Sr-89 Sr-90 6.2.1.1-3 Amendment 35, MAR 2002
Liquid Dose 6.2.1.2 6.2 RADIOACTIVE EFFLUENTS 6.2.1 Liquid Effluents 6.2.1.2 Liquid Dose RFO 6.2.1.2 APPLICABILITY:
The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released to UNRESTRICTED AREAS (see ODCM Figure 3-1) shall be limited to:
- a.
< 1.5 mrem to the total body and < 5 mrem to any organ during any calendar quarter; and
- b.
< 3 mrem to the total body and < 10 mrem to any organ during any calendar year.
When radioactive liquid effluents are released.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 6.2.1.2-1
Liquid Dose 6.2.1.2 COMPENSATORY MEASURES
NOTE --------------------------------------
Enter applicable Conditions and Required Compensatory Measures of ODCM 6.2.3, "Total Dose," when the calculated dose from liquid effluents exceeds twice the limits of RFO 6.2.1.2.
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Calculated dose from A.1 Submit a Special Report 30 days the release of to the NRC that radioactive materials identifies causes for in liquid effluents to exceeding limits, Unrestricted Areas not corrective actions taken within limits, to reduce releases, corrective actions to assure that subsequent releases will be in compliance with the required limits, results of radiological analyses of drinking water
- source, and the radiological impact on potentially affected drinking water supplies with regard to 40 CFR 141.
SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.2.1.2.1 Verify the cumulative dose contributions 31 days from radioactive liquid effluents for the current calendar quarter and current calendar year are within limits in accordance with the methodology and parameters in the ODCM.
Columbia Generating Station 6.2.1.2-2 Amendment 35, MAR 2002
Liquid Waste Management System 6.2.1.3 6.2 RADIOACTIVE EFFLUENTS 6.2.1 Liquid Effluents 6.2.1.3 Liquid Waste Management System RFO 6.2.1.3 APPLICABILITY:
The Liquid Waste Management System shall be OPERABLE.
Appropriate portions of the system shall be used to reduce the radioactive materials in liquid waste prior to discharge when the projected doses due to the liquid effluent, from the reactor unit to UNRESTRICTED AREAS, would exceed 0.06 mrem to the total body or 0.2 mrem to any organ in a 31 day period.
At all times.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Liquid waste being A.1 Submit a Special Report 30 days discharged without to the NRC that includes treatment when RFO explanation of why the 6.2.1.3 limits are Liquid Waste Management exceeded.
System was not OPERABLE or why liquid radwaste was being discharged without treatment.
The Special Report shall identify any required inoperable equipment and the reasons for the inoperability, the corrective actions taken to restore the required inoperable equipment to OPERABLE status, and the corrective actions to prevent recurrence.
Columbia Generating Station Amendment 35, MAR 2002 6.2.1.3-1
Liquid Waste Management System 6.2.1.3 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.2.1.3.1 Dose due to liquid releases to Prior to each UNRESTRICTED AREAS shall be projected in batch release accordance with the methodology and parameters in the ODCM.
SR 6.2.1.3.2 The installed Liquid Waste Management See RFOs System shall be demonstrated OPERABLE by 6.2.1.1 and meeting RFOs 6.2.1.1 and 6.2.1.2.
6.2.1.2 Columbia Generating Station Amendment 35, MAR 2002 6.2.1.3-2
Dose Rate 6.2.2.1 6.2 RADIOACTIVE EFFLUENTS 6.2.2 Gaseous Effluents 6.2.2.1 Dose Rate RFO 6.2.2.1 APPLICABILITY:
The dose rate at and beyond the SITE BOUNDARY (See Figure 3-1) due to radioactive materials released in gaseous effluents from the site shall be limited to the following:
- a.
For nobles gases, less than or equal to 500 mrem per year to the total body and less than or equal to 3000 mrem per year to the skin; and
- b.
For iodine-131, iodine-133, tritium, and all radionuclides in particulate form with half lives >8 days, less than or equal to 1500 mrem per year to any organ.
At all times.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Dose rate from the A.1 Initiate action to Immediately release of radioactive restore dose rate to materials in gaseous within limits.
effluents at and beyond the SITE BOUNDARY not within limits.
Columbia Generating Station 6.2.2.1-1 Amendment 35, MAR 2002
Dose Rate 6.2.2.1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.2.2.1.1 Verify the dose rate due to noble gases In accordance in gaseous effluents is within limits in with Table accordance with methodology and 6.2.2.1-1 parameters in the ODCM.
SR 6.2.2.1.2 Verify dose rate due to iodine-131, In accordance iodine-133, tritium, and all with Table radionuclides in particulate form with 6.2.2.1-1 half lives >8 days in gaseous effluents is within limits in accordance with the methodology and parameters in the ODCM by obtaining representative samples and performing analyses.
Columbia Generating Station 6.2.2.1-2 Amendment 35, MAR 2002
Dose Rate 6.2.2.1 Table 6.2.2.1-1 Part 1 (Page 1 of 5)
Radioactive Gaseous Waste Sampling and Analysis Program Requirements Applicable At All Times SAMPLE TYPE SAMPLE MINIMUM TYPE OF SAMPLE LOWER FREQUENCY ANALYSIS ACTIVITY LIMIT OF FREQUENCY ANALYSIS DETECTION (LLD)
Primary Containment 31 days 31 days Tritium I X 10.6 Tritium Grab Sample(a) yCi/ml Reactor Building 7 days 7 days Tritium I X 10.6 Elevated Discharge Vent pCi/ml Tritium Grab Sample Reactor Building 31 Days 31 Days Principal 1 X 10,4 Elevated Discharge Gamma pCi/ml Noble Gas Grab Sample Emitters Turbine and Radwaste 31 Days 31 Days Principal i X 10.1 Building Vent Noble Gas Gamma pCi/ml and Tritium Grab Emitters Samples Tritium 1 X 10.6 pCi/ml Charcoal Filter Sample C-"tinuous 7 days 1-131 1 X 10.12 (All Building Vents)
,D)(c)
Ci /ml 1-133 1 X 10"10 pCi/ml Particulate Filter Continuous 7 days Principal 1 X 1011 Sample (All Building (b)(c)
Gamma pCi/ml Vents)
Emitters (continued)
(a)
Not required when Primary Containment is not required.
(b)
The ratio of the sample flow rate to the sampled stream flow rate shall be known for the time period covered by each dose or dose rate calculation made in accordance with RFOs 6.2.2.1, 6.2.2.2, and 6.2.2.3.
(c)
Analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after changing, or after removal from the sampler.
Columbia Generating Station 6.2.2.1-3 Amendment 35, MAR 2002
Dose Rate 6.2.2.1 Table 6.2.2.1-1 Part 1 (Page 2 of 5)
Radioactive Gaseous Waste Sampling and Analysis Program Requirements Applicable At All Times SAMPLE TYPE SAMPLE MINIMUM TYPE OF SAMPLE LOWER FREQUENCY ANALYSIS ACTIVITY LIMIT OF FREQUENCY ANALYSIS DETECTION (LLD)
Composite of Continuous 31 days Gross Alpha 1 X 10.11 Particulate Filter (b) pCi/ml Samples (All Building Vents)
Composite of Continuous 92 days Sr-89, 1 X 10.11 Particulate Filter (b)
Sr-90 pCi/ml Samples (All Building Vents)
Noble Gas (All Building Continuous Gross Beta 1 X 10.6 Vents) or Gamma kCi/ml (Xe-133 Equivalent)
(b)
The ratio of the sample flow rate to the sampled stream flow rate shall be known for the time period covered by each dose or dose rate calculation made in accordance with RFOs 6.2.2.1, 6.2.2.2, and 6.2.2.3.
Columbia Generating Station Amendment 35, MAR 2002 6.2.2.1-4
Dose Rate 6.2.2.1 Table 6.2.2.1-1 Part 2 (Page 3 of 5)
Radioactive Gaseous Waste Sampling and Analysis Program Requirements Applicable During PURGE and VENT SAMPLE TYPE SAMPLE MINIMUM TYPE OF SAMPLE LOWER FREQUENCY ANALYSIS ACTIVITY LIMIT OF FREQUENCY ANALYSIS DETECTION (LLD)
Primary Containment 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> 8 hours Principal 1 X 10-4 Purge and Vent Noble prior to prior to Gamma yCi/ml
- Gas, Iodine, and each PURGE each PURGE Emitters Particulate Grab and VENT and VENT Sample(d)(e)
(d)
Sampling and analysis is not required for a Primary Containment VENT when the VENT path is through the Standby Gas Treatment System via the two-inch bypass line and when containment noble gas monitoring instrumentation indicates less than the alarm setpoint.
(e)
If the Reactor Building Elevated Discharge Low Range Radiation Monitor is not OPERABLE, sampling and analysis of the containment shall be completed at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> during VENT or PURGE.
Columbia Generating Station Amendment 35, MAR 2002 6.2.2.1-5
Dose Rate 6.2.2.1 Table 6.2.2.1-1 Part 3 (Page 4 of 5)
Radioactive Gaseous Waste Sampling and Analysis Program Requirements During Startup and Shutdown SAMPLE TYPE SAMPLE MINIMUM TYPE OF SAMPLE LOWER FREQUENCY ANALYSIS ACTIVITY LIMIT OF FREQUENCY ANALYSIS DETECTION (LLD)
Primary Containment and Once Once Principal 1 X 10.1 Reactor Building following following Gamma ASCi/ml Elevated Discharge startup or startup or Emitters Noble Gas, Iodine, and shutdown shutdown Particulate Grab Sample Charcoal Filter Sample Continuous (f) 1-131 1 X 10-12 (All Building Vents)
(b) yCi/ml 1-133 1 X 10"10
- tCi /ml Particulate Filter Continuous (f)
Principal 1 X 10.11 Sample (All Building (b)
Gamma ACi/ml Vents)
Emitters (continued)
(b)
The ratio of the sample flow rate to the sampled stream flow rate for the time period covered by each dose or dose rate calculation accordance with RFOs 6.2.2.1. 6.2.2.2, and 6.2.2.3.
shall be known made in (f)
Filters shall be removed from the continuous sampler at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for at least 7 days following each shutdown or startup, and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of filter removal.
When samples collected for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> are analyzed, the corresponding LLDs may be increased by a factor of 10.
Requirement (1) a.
(f) does not apply if:
Analysis shows that the DOSE EQUIVALENT 1-131 concentration in the primary coolant is less than or equal to 1.OE-03 pCi/cc.
Or
- b.
When the DOSE EQUIVALENT 1-131 concentration in the primary coolant is greater than 1.OE-03 pCi/cc, but has not increased more than a factor of 3; And (2)
- a.
When any building vent noble gas monitor is less than or equal to 2.0% of the setpoint determined in accordance with ODCM Section 3.4.
Or
- b.
When any building vent noble gas monitor is greater than 2.0% of its setpoint. but shows that effluent activity has not increased by more than a factor of 3.
Columbia Generating Station 6.2.2.1-6 Amendment 35, MAR 2002
Dose Rate 6.2.2.1 Table 6.2.2.1-1 Part 4 (Page 5 of 5)
Radioactive Gaseous Waste Sampling and Analysis Program Requirements During Reactor Power Changes SAMPLE TYPE SAMPLE MINIMUM TYPE OF SAMPLE LOWER FREQUENCY ANALYSIS ACTIVITY LIMIT OF FREQUENCY ANALYSIS DETECTION (LLD)
Primary Containment and (g)
(g)
Principal 1 X 10-4 Reactor Building Gamma
'aCi/ml Elevated Discharge Emitters Noble Gas, Iodine, and Particulate Grab Sample Charcoal Filter Sample Continuous (h) 1-131 1 X 10.12 (All Building Vents)
(b) jiCi/ml 1-133 1 X 10"10 yCi/ml Particulate Filter Continuous (h)
Principal 1 X 1011 Sample (All Building (b)
Gamma
'Ci/ml Vents)
Emitters (b)
The ratio of the sample flow rate to the sampled stream flow rate shall be known for the time period covered by each dose or dose rate calculation made in accordance with RFOs 6.2.2.1.
6.2.2.2, and 6.2.2.3.
(g)
Grab sampling and analysis shall be performed following a THERMAL POWER change exceeding 15%
of RATED THERMAL POWER within a 1-hour period when the noble gas release rate, as indicated by the main condenser offgas pretreatment monitor, is greater than 15,000 pCi/sec.
(h)
Filters shall be removed from the continuous samplers at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for at least 7 days following each THERMAL POWER change exceeding 15% of RATED THERMAL POWER in one hour when the noble gas release rate, as indicated by the main condenser offgas pretreatment monitor, is greater than 15,000 ACi/sec.
Analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of filter change.
When samples collected for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> are analyzed, the corresponding LLDs may be increased by a factor of 10.
Requirement (h)
(1) a.
does not apply if:
Analysis shows that the DOSE EQUIVALENT 1-131 concentration in the primary coolant is less than or equal to 1.0E-03 pCi/cc.
Or b
When the DOSE EQUIVALENT 1-131 concentration in the primary coolant is greater than I.OE-03 kCi/cc, but has not increased more than a factor of 3:
And (2)
- a.
When any building vent noble gas monitor is less than or equal to 2.0% of the setpoint determined in accordance with ODCM Section 3.4.
Or
- b.
When any building vent noble gas monitor is greater than 2.0% of its setpoint, but shows that effluent activity has not increased by more than a factor of 3.
Columbia Generating Station 6.2.2.1-7 Amendment 35, MAR 2002
Dose - Noble gases 6.2.2.2 6.2 RADIOACTIVE EFFLUENTS 6.2.2 Gaseous Effluents 6.2.2.2 Dose - Noble Gases RFO 6.2.2.2 APPLICABILITY:
The air dose at and beyond the SITE BOUNDARY from noble gases in gaseous effluents from the site shall be limited to the following:
- a.
< 5 mrads gamma radiation and <= 10 mrads beta radiation during any calendar quarter; and
- b.
< 10 mrads gamma radiation and <= 20 mrads beta radiation during any calendar year.
At all times.
COMPENSATORY MEASURES
NOTE --------------------------------------
Enter applicable Conditions and Required Compensatory Measures of 6.2.3. Total Dose, when gaseous effluent (noble gas) dose exceeds twice the limits of RFO 6.2.2.2.
CONDITION REOUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Calculated air dose A.1 Submit a Special Report 30 days from radioactive noble to the NRC that gases in gaseous identifies causes for effluents in the exceeding the limits, UNRESTRICTED AREA not corrective actions taken within limits, to reduce releases, and corrective actions to assure that subsequent releases are within limits.
Columbia Generating Station Amendment 35, MAR 2002 6.2.2.2-1
Dose - Noble gases 6.2.2.2 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.2.2.2.1 Verify the cumulative dose contributions 31 days from noble gases in gaseous effluents for the current calendar quarter and current calendar year are within limits in accordance with the methodology and parameters in the ODCM.
Columbia Generating Station 6.2.2.2-2 Amendment 35, MAR 2002
Dose -
1-131, 1-133, Tritium, and Radionuclides in Particulate Form 6.2.2.3 6.2 RADIOACTIVE EFFLUENTS 6.2.2 Gaseous Effluents 6.2.2.3 Dose -
1-131, 1-133, Tritium, and Radionuclides in Particulate Form RFO 6.2.2.3 APPLICABILITY:
The dose to any organ of a MEMBER OF THE PUBLIC from iodine
- 131, iodine-133, tritium, and all radionuclides in particulate form with half lives > 8 days in gaseous effluents released to the UNRESTRICTED AREA shall be limited to the following:
- a.
< 7.5 mrems during any calendar quarter; and
- b.
< 15 mrems during any calendar year.
At all times.
COMPENSATORY MEASURES
NOTE --------------------------------------
Enter applicable Conditions and Required Compensatory Measures of 6.2.3, Total Dose, when gaseous effluent dose from 1-131, 1-133, Tritium, and Radionuclides in Particulate Form exceeds twice the limits of RFO 6.2.2.3.
CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Calculated dose from A.1 Submit a Special Report 30 days the release of iodine-to the NRC that
- 131, iodine-133, identifies causes for tritium, and exceeding the limits, radionuclides in corrective actions taken particulate form with to reduce releases, and half-lives > 8 days, corrective actions to in gaseous effluents assure that subsequent in the UNRESTRICTED releases are within AREA not within limits.
limits.
Columbia Generating Station Amendment 35, MAR 2002 6.2.2.3-1
Dose 1-131, 1-133, Tritium, and Radionuclides in Particulate Form 6.2.2.3 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.2.2.3.1 Verify the cumulative dose contributions 31 days from iodine-131, iodine-133, tritium, and radionuclides in particulate form with half lives > 8 days, in gaseous effluents for the current calendar quarter and current calendar year are within limits in accordance with the methodology and parameters in the ODCM.
Columbia Generating Station 6.2.2.3-2 Amendment 35, MAR 2002
Gaseous Offgas Treatment System 6.2.2.4 6.2 RADIOACTIVE EFFLUENTS 6.2.2 Gaseous Effluents 6.2.2.4 Gaseous Offgas Treatment System RFO 6.2.2.4 APPLICABILITY:
The Gaseous Offgas Treatment System shall be in operation in either:
- a.
The normal mode; or
- b.
The charcoal bypass mode, provided the offgas post treatment radiation monitor is OPERABLE as specified in Table 6.1.2-1.
Whenever the main condenser steam jet air ejector system is in operation.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Gaseous Offgas A.1 Place Gaseous Offgas 7 days Treatment System not Treatment System in the in the normal mode of normal mode of operation.
operation.
B.
Required B.1 Submit a Special Report 30 days Compensatory Measure to the NRC that A.1 and associated identifies the required Completion Time not inoperable equipment and met.
the reasons for the inoperability, corrective actions taken to restore the required inoperable equipment to OPERABLE status, and the corrective actions to prevent recurrence.
Columbia Generating Station Amendment 35, MAR 2002 6.2.2.4-1
Gaseous Offgas Treatment System 6.2.2.4 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.2.2.4.1 Verify Gaseous Offgas Treatment System in 7 days operation in either:
a) The normal mode; or b)
The charcoal bypass mode, provided the offgas post-treatment radiation monitor is OPERABLE.
Columbia Generating Station 6.2. 2.4-L Amendment 35, MAR 2002
Reactor Building Sump Vent Exhaust Filter System 6.2.2.5 6.2 RADIOACTIVE EFFLUENTS 6.2.2 Gaseous Effluents 6.2.2.5 Reactor Building Sump Vent Exhaust Filter System RFO 6.2.2.5 APPLICABILITY:
The appropriate portions of the Reactor Building Sump Vent Exhaust Filter System shall be OPERABLE.
The system shall be used to reduce radioactive materials in gaseous waste prior to their discharge when the projected doses due to gaseous effluent, from the reactor unit to a MEMBER OF THE PUBLIC in the UNRESTRICTED AREAS when averaged over 31 days, would exceed 0.3 mrem to any organ in a 31 day period.
At all times.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Gaseous waste being A.1 Submit a Special Report 30 days discharged without to the NRC that Reactor Building Sump identifies inoperable Vent Exhaust Filter equipment or subsystems System treatment when and the reasons for projected organ dose inoperability, the exceeds 0.3 mrem.
corrective actions taken to restore the inoperable equipment to OPERABLE status, and the corrective actions to prevent recurrence.
Columbia Generating Station Amendment 35, MAR 2002 6.2.2.5-1
Reactor Building Sump Vent Exhaust Filter System 6.2.2.5 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.2.2.5.1 Determine the projected organ doses due 31 days to gaseous releases to a MEMBER OF THE PUBLIC in the UNRESTRICTED AREA in accordance with the methodology and parameters in the ODCM.
SR 6.2.2.5.2 The Reactor Building Sump Vent Exhaust Once per 92 Filter System shall be demonstrated days OPERABLE by operating the system for at least I0 minutes unless the system has been utilized to process radioactive gaseous effluents during the previous 92 days.
Columbia Generating Station 6.2.2.5-2 Amendment 35, MAR 2002
VENTING or PURGING 6.2.2.6 6.2 RADIOACTIVE EFFLUENTS 6.2.2 Gaseous Effluents 6.2.2.6 VENTING or PURGING RFO 6.2.2.6 APPLICABILITY:
VENTING or PURGING of the primary containment shall be:
- a.
Through one functional-for-filtration Standby Gas Treatment (SGT)
System train during MODES 1, 2, or 3 provided the other train is OPERABLE during the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of any VENTING or PURGING operation; or
- b.
Through one or two functional-for-filtration SGT System train(s) when deinerting the containment in MODE 4 during the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of any VENTING or PURGING operation; or
- c.
Through the Primary Containment VENT and PURGE System when not using SGT following the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of any VENTING and PURGING operation.
MODES 1, 2, and 3 when VENTING or PURGING and when deinerting the containment.
Not applicable during containment depressurization following 10 CFR 50, Appendix J, Type A testing.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Requirements of A.1 Suspend VENTING and Immediately 6.2.2.6 not met.
PURGING of the containment.
Columbia Generating Station Amendment 35, MAR 2002 6.2.2.6-1
VENTING or PURGING 6.2.2.6 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.2.2.6.1 Verify the containment is aligned for Within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> VENTING or PURGING through the SGT system prior to the or the Primary Containment VENT and PURGE start and once System.
per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> during PURGING or VENTING Columbia Generating Station 6.2.2.6-2 Amendment 35, MAR 2002
Total Dose 6.2.3 6.2 RADIOACTIVE EFFLUENTS 6.2.3 Total Dose The annual dose or dose commitment to a MEMBER OF THE PUBLIC in the UNRESTRICTED AREA due to releases of radioactivity and radiation from uranium fuel cycle sources shall be limited to:
- a.
< 25 mrem to the total body or any organ except the thyroid; and
- b.
< 75 mrem to the thyroid.
APPLICABILITY:
At all times.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Calculated dose to any A.1 --------- NOTE ----------- Immediately MEMBER OF THE PUBLIC Calculations shall in the UNRESTRICTED include direct radiation AREA exceeds twice the contributions from the limits of 6.2.1.2 or reactor, outside storage 6.2.2.2 or 6.2.2.3.
tanks, and the Independent Spent Fuel Storage Installation (ISFSI).
Calculate the dose or dose commitment to a MEMBER OF THE PUBLIC from all uranium fuel cycle sources to determine if specified limits of RFO 6.2.3 were exceeded.
(continued)
Columbia Generating Station RFO 6.2.3 Amendment 35, MAR 2002 6.2.3-1
Total Dose 6.2.3 COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME B.
Calculated dose or B.1 Submit a Special Report 30 days dose commitment to the NRC pursuant to exceeds specified 10 CFR 50, Appendix I, limits of RFO 6.2.3.
Section IV.A, that includes corrective actions taken to prevent recurrence, the schedule for achieving conformance with required limits, an analysis that estimates the radiation exposure to a MEMBER OF THE PUBLIC from uranium fuel cycle sources for the calendar year, descriptions of the levels of radiation and concentrations of radioactive material involved, and the cause of the exposure levels or concentrations.
AND (continued)
Columbia Generating Station 6.2.3-2 Amendment 35, MAR 2002
Total Dose 6.2.3 COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME B.
(continued)
B.2 ---------- NOTE ------------
30 days
- 1. Only applicable if the release condition resulting in violation of 40 CFR 190 has not been corrected.
- 2. Special Report submitted is considered a timely request and a variance is granted until NRC action on the request is complete.
Submit a request for a variance in accordance with 40 CFR 190 in the Special Report to the NRC.
SURVEILLANCE REQUIREMENTS SUI.,"LILLANCE FREOUENCY SR 6.2.3.1 Cumulative dose contributions from liquid 31 days and gaseous effluents shall be determined in accordance with SRs 6.2.1.2.1, 6.2.2.2.1, and 6.2.2.3.1.
Columbia Generating Station Amendment 35, MAR 2002 6.2.3-3
Radiological Environmental Monitoring Program 6.3.1 6.3 RADIOLOGICAL ENVIRONMENTAL MONITORING 6.3.1 Radiological Environmental Monitoring Program RFO 6.3.1 The Radiological Environmental Monitoring Program shall be as follows:
- a.
Radiological Environmental Monitoring samples shall be collected at locations and analyzed as specified in Table 6.3.1-1;
- b.
The level of radioactivity as the result of plant effluents for a single radionuclide in each environmental sampling medium at a required location shall be less than the limits specified in Table 6.3.1-2, when averaged over the calendar quarter;
- c.
The total level of radioactivity in multiple detected radionuclides as the result of plant effluents in each environmental sampling medium at a required location shall be less than the limit specified in Table 6.3.1-2, when averaged over the calendar quarter; and
- d.
The potential annual dose to the MEMBER OF THE PUBLIC from all radionuclides other than those in Table 6.3.1-2 in each environmental sampling medium at a required location shall be less than the calendar year limits of RFOs 6.2.1.2. 6.2.2.2, and 6.2.2.3.
APPLICABILITY:
At all times.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 6.3.1-1
Radiological Environmental Monitoring Program 6.3.1 COMPENSATORY MEASURES CONDITION REOUIRED COMPENSATORY MEASURE COMPLETION TIME A.
One or more samples A.1 Prepare and submit, in Upon submittal not collected or the Annual Radiological of current analyzed as specified Environmental Operating Annual in Table 6.3.1-1.
- Report, a description Radiological for not conducting the Environmental Radiological Operating Report Environmental Monitoring sampling and analysis requirements as required and the corrective actions to prevent recurrence.
B. --------
NOTE---------- B.1 Identify locations for 30 days Separate Condition obtaining replacement entry is allowed for samples and replace, in each sample location, the Radiological Environmental Monitoring Program, the location(s)
One or more sample from which samples are locations required by unavailable with the new Table 6.3.1-1 with location(s).
milk or fresh leafy vegetable samples AND unavailable.
B.2 Prepare and submit, in Upon submittal the Radiological of current Environmental Operating Radiological Report, the cause of the Environmental unavailability of Operating Report samples, the new locations for obtaining replacement samples, and the revised figure(s) and table(s) for the ODCM reflecting the new locations.
(continued)
Columbia Generating Station 6.3.1-2 Amendment 35, MAR 2002
Radiological Environmental Monitoring Program 6.3.1 COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME C. - -------- NOTE-------
Separate Condition entry is allowed for each sample location.
One or more sample locations with the level of radioactivity for one radionuclide as the result of plant effluents in an environmental sampling medium not within the limits of Table 6.3.1 2 when averaged over the calendar quarter.
O R One or more sample locations with the total level of radioactivity for more than one radionuclide as a result of plant effluents in an environmental sampling medium not within the limits of Table 6.3.1 2 when averaged over the calendar quarter.
L C.1 Submit a Special Report to the NRC which includes the cause(s) for exceeding the limit(s) and the corrective actions to reduce radioactive effluents so that the potential annual dose to a MEMBER OF THE PUBLIC is less than the calendar year reporting limits of RFOs 6.2.1.2, 6.2.2.2, and 6.2.2.3.
30 days (continued)
Columbia Generating Station 6.3.1-3 Amendment 35, MAR 2002
Radiological Environmental Monitoring Program 6.3.1 COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME D.
One or more sample locations with the potential annual dose to the MEMBER OF THE PUBLIC from radionuclides other than those in Table 6.3.1-2 not within lmits.
D.1
NOTE--------
Only required if the radionuclides are the result of plant effluents.
Submit a Special Report to the NRC which includes the cause(s) for exceeding the limit(s) and the corrective actions to reduce radioactive effluents so that the potential annual dose to a MEMBER OF THE PUBLIC is less than the calendar year limits of RFOs 6.2.1.2, 6.2.2.2, and 6.2.2.3.
AND D.2 ---------- NOTE-------
Only required if the radionuclides are not the result of plant effluents.
Describe the condition in the Annual Radiological Environmental Operating Report.
30 days Upon submittal of the current calendar year Annual Radiological Environmental Operating Report Columbia Generating Station Amendment 35, MAR 2002 6.3.1-4
Radiological Environmental Monitoring Program 6.3.1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.3.1.1 Verify radiological environmental In accordance monitoring samples collected at the with Table locations and analyzed as specified in 6.3.1-1 Table 6.3.1-1 are within limits.
Detection capabilities for the analysis are specified in Table 6.3.1-3.
Columbia Generating Station Amendment 35, MAR 2002 6.3.1-5
Radiological Environmental Monitoring Program 6.3.1 TABLE 6.3.1-1 (page I of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM EXPOSURE PATHWAY NUMBER OF REPRESENTATIVE SAMPLES SAMPLING AND TYPE AND AND/OR SAMPLE AND SAMPLE LOCATIONS(a)
COLLECTION FREQUENCY OF FREQUENCY ANALYSIS
- 1.
DIRECT Thirty-four routine monitoring Quarterly.
Gamma dose RADIATION(b) stations either with two or more quarterly.
dosimeters or with one instrument for measuring and recording dose rate continuously, placed as follows:
An inner ring of stations, one in each meteorological sector in the general area of the SITE BOUNDARY.
An outer ring of stations, one in each of the meteorological sectors of NE,
- ENE, E. ESE, SE in the six to nine km range from the site, and one in each of the meteorological sectors of N, NNE, SSE.
S. SSW in the nine to twelve km range from the site.
The balance of the stations to be placed in special interest areas such as population centers, nearby residences, schools, and one or two areas to serve as control stations.
Additional monitoring stations for the Independent Spent Fuel Storage Installation (ISFSI).
(continued)
(a)
Specific parameters of distance and direction sector relative to the reactor are provided for each sample location in Table 5.1.
Refer to Radiological Assessment Branch Technical Position, Revision 1, November 1979.
Deviations are permitted from the required sampling schedule if specimens are unobtainable due to circumstances such as hazardous conditions, seasonal unavailability, and malfunction of automatic sampling equipment.
(b)
One or more instruments, such as a pressurized ion chamber, for measuring and recording dose rate continuously may be used in place of, or in addition to, integrating dosimeters.
For the purposes of this table, a thermoluminescent dosimeter (TLD) is considered to be one phosphor card with multiple readout areas; a phosphor card in a packet is considered to be equivalent to two or more dosimeters.
Film badges shall not be used as dosimeters for measuring direct radiation.
(The number of direct radiation monitoring stations may be reduced according to geographical limitations.
The frequency of analysis or readout for TLD systems will depend upon the characteristics of the specific system used and should be selected to obtain optimum dose information with minimal fading.)
Columbia Generating Station 6.3.1-6 Amendment 35, MAR 2002
Radiological Environmental Monitoring Program 6.3.1 TABLE 6.3.1-1 (page 2 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM EXPOSURE PATHWAY NUMBER OF REPRESENTATIVE SAýMPLES SAMPLING AND TYPE AND AND/OR SAMPLE AND SAMPLE LOCATIONS(a)
COLLECTION FREQUENCY OF FREQUENCY ANALYSIS
- 2.
AIRBORNE Radiolodine Samples from six locations:
Continuous sampler Radioiodine and operation with Canister:
Particulates One sample from close to the SITE sample collection 1-131 analysis BOUNDARY location, having a high weekly, or more weekly.
calculated annual average ground-frequently if level D/Q.
required by dust Particulate loading.
Sampler:
Three samples from close to the Gross beta three Columbia River locations radioactivity having the highest calculated D/0.
analysis following One sample from the vicinity of a filter community having the highest change,(c) calculated annual average ground level D/Q.
One sample from a control location, Gamma isotpic as for example 30-50 km distant and analysis in the least prevalent wind of composite direction.
(by location) quarterly.
(continued)
(a)
Specific parameters of distance and direction sector relative to the reactor are provided for each sample location in Table 5.1.
Refer to Radiological Assessment Branch Technical Position, Revision 1, November 1979.
Deviations are permitted from the required sampling schedule if specimens are unobtainable due to circumstances such as hazardous conditions, seasonal unavailability, and malfunction of automatic sampling equipment.
(c)
Airborne hours or activity
- samples, particulate sample filters shall be analyzed for gross beta radioactivity 24 more after sampling to allow for radon and thorium daughter decay.
If gross beta in air particulate samples is greater than 10 times the yearly mean of control gamma isotopic analysis shall be performed on the individual samples.
(d)
Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.
Columbia Generating Station 6.3.1-7 Amendment 35, MAR 2002
Radiological Environmental Monitoring Program 6.3.1 TABLE 6.3.1-1 (page 3 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM EXPOSURE PATHWAY NUMBER OF REPRESENTATIVE SAMPLES SAMPLING AND TYPE AND AND/OR SAMPLE AND SAMPLE LOCATIONS(a)
COLLECTION FREQUENCY OF FREQUENCY ANALYSIS
- 3.
WATERBORNE One sample upstream Composite sample Gamma is9tMPIC
- a.
Surface(e)
One sample downstream over onefmonth analysis period.
monthly.
Composite for tritium analysis quarterly.
Gamma Samples from one or two source Quarterly.
isotopic~d)
- b. Ground only if likely to be affected.
and tritium analysis quarterly.
(continued)
(a)
Specific parameters of distance and direction sector relative to the reactor are provided for each sample location in Table 5.1.
Refer to Radiological Assessment Branch Technical Position, Revision 1. November 1979.
Deviations are permitted from the required sampling schedule if specimens are unobtainable due to circumstances such as hazardous conditions.
seasonal unavailability, and malfunction of automatic sampling equipment.
(d)
Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.
(e)
The "upstream sample" shall be taken at a distance beyond significant influence of the discharge.
The "downstream" sample shall be taken in an area beyond but near the mixing zone Cf)
A composite sample is one in which the quantity (aliquot) of liquid is proportional to the quantity of flowing liquid and in which the method of sampling employed results in a
specimen that is representative of the liquid flow.
In this program composite sample aliquots shall be collected at time intervals that are very short (e.g., hourly) relative to the compositing period (e.g.,
monthly) in order to assure obtaining a representative sample.
(g)
Groundwater samples shall be taken when this source is tapped for drinking or irrigation purposes in areas where the hydraulic gradient or recharge properties are suitable for contamination.
Columbia Generating Station Amendment 35, MAR 2002 6.3.1-8
Radiological Environmental Monitoring Program 6.3.1 TABLE 6.3.1-1 (page 4 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM EXPOSURE PATHWAY NUMBER OF REPRESENTATIVE SAMPLES SAMPLING AND TYPE AND AND/OR SAMPLE AND SAMPLE LOCATIONS(a)
COLLECTION FREQUENCY OF FREQUENCY ANALYSIS
- 3.
WATERBORNE C(conti nued)
One sample of each of one to three Composite sample 1-131 analysis
- c.
Drinking of the nearest water supplies that over tw?)week on each could be affected by its discharge.
period when composite when 1-131 analysis is the dose performed; monthly calculated for composite the otherwise.
consumption of the water is greater than one mrem per year.(h)
One sample from a control location.
Composite for gross beta and gamma is plc analysis monthly.
Composite for tritium analysis quarterly.
- d.
Sediment One sample from downstream area Semiannually.
Gamma isotopic from with existing or potential analysis shoreline recreational value semiannually.
(continued)
(a)
Specific parameters of distance and direction sector relative to the reactor are provided for each sample location in Table 5.1.
Refer to Radiological Assessment Branch Technical Position, Revision 1, November 1979.
Deviations are permitted from the required sampling schedule if specimens are unobtainable due to circumstances such as hazardous conditions, seasonal unavailability, and malfunction of automatic sampling equipment.
(d)
Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.
(f)
A composite sample is one in which the quantity (aliquot) of liquid is proportional to the quantity of flowing liquid and in which the method of sampling employed results in a specimen that is representative of the liquid flow.
In this program composite sample aliquots shall be collected at time intervals that are very short (e.g.,
hourly) relative to the compositing period (e.g., monthly) in order to assure obtaining a representative sample.
(h)
The dose shall be calculated for the maximum organ and age group, using the methodology and parameters in the ODCM.
Columbia Generating Station Amendment 35, MAR 2002 6.3.1-9
Radiological Environmental Monitoring Program 6.3.1 TABLE 6.3.1-1 (page 5 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM EXPOSURE PATHWAY NUMBER OF REPRESENTATIVE SAMPLES SAMPLING AND TYPE AND AND/OR SAMPLE AND SAMPLE LOCATIONS(a COLLECTION FREQUENCY OF FREOUENCY ANALYSIS
- 4.
INGESTION
- a.
Milk Samples from milking animals in Semimonthly when Gamma three locations within five km animals are on isotopic(d)(k) distance having the highest dose pasture, monthly and 1-131 potential.
If there are none, then at other times, analysis semi one sample from milking animals in monthly when each of three areas between 5-16 km animals are on distant where doses are calculated pasture; to beageater than 1 mrem per monthly at year.
other times.
One sample from milking animals at a control location, 30-50 km distant and in the least prevalent wind direction.
- b. Fish and One sample of each of three Sample annually, Gamma is pic Invertebrates recreationally important species unless an impact analysis on (one anadromous and two resident) is indicated, then edible in vicinity of plant discharge semiannually. (i) portions.
area.
One sample of same species in areas not influenced by plant discharge.
(continued)
(a)
Specific parameters of distance and direction sector relative to the reactor are provided for each sample location in Table 5.1.
Refer to Radiological Assessment Branch Technical Position, Revision 1, November 1979.
Deviations are permitted from the required sampling schedule if specimens are unobtainable due to circumstances such as hazardous conditions, seasonal unavailability, and malfunction of automatic sampling equipment.
(d)
Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.
(h)
The dose shall be calculated for the maximum organ and age group, using the methodology and parameters in the ODCM.
0i)
If any of the analytical results for Columbia River fish samples are significantly higher than the results of the Snake River samples or the results of previous fish samples, sampling will be conducted semiannually.
(k)
If Cs-134 or Cs-137 is measured in an individual milk sample in excess of 30 pCIce, then Sr-90 analysis shall be performed.
Columbia Generating Station Amendment 35, MAR 2002 6.3. 1-1C
Radiological Environmental Monitoring Program 6.3.1 TABLE 6.3.1-1 (page 6 of 6)
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM EXPOSURE PATHWAY NUMBER OF REPRESENTATIVE SAýMPLES SAMPLING AND TYPE AND AND/OR SAMPLE AND SAMPLE LOCATIONS(a COLLECTION FREQUENCY OF FREQUENCY ANALYSIS
- 4.
INGESTION (continued)
- c.
Food 1 sample of each principal class of At time of Gamma isMpi c Products food products from any area that is harvest.J) analyses on irrigated by water in which liquid edible plant wastes have been discharged.
portion.
Samples of three different kinds of Monthly during Gamma broad leaf vegetation grown nearest growing season.
isotopic(d) each of two different offsite and 1-131 locations of highest predicted analysis.
annual average ground-level D/Q if milk sampling is not performed.
One sample of each of the similar Monthly during Gamma broad leaf vegetation grown 30-50 growing season.
isotopic(d) km distant ;n the least prevalent and 1-131 wind direction if milk sampling is analysis.
not performed.
(a)
Specific parameters of distance and direction sector relative to the reactor are provided for each sample location in Table 5.1.
Refer to Radiological Assessment Branch Technical Position. Revision 1. November 1979.
Deviations are permitted from the required sampling schedule if specimens are unnbtainable due to circumstances such as hazardous conditions, seasonal unavailability, a - r~jlfunction of automatic sampling equipment.
(d)
Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be c'tifbutable to the effluents from the facility.
(3)
If harvest occurs more than onre a year, sampling shall be performed harvest.
If harvest occurs continuously, sampling shall be monthly.
paid to including samples of tuberous and root food products.
during each discrete Attention shall be Columbia Generating Station Amendment 35, MAR 2002 6.3.1-11
Radiological Environmental Monitoring Program 6.3.1 TABLE 6.3.1-2 REPORTING LEVELS FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES(2)
AIRBORNE FOOD PARTICULATE PRODUCTS WATER OR GASES FISH MILK (pCi/kg, ANALYSIS (pCi/L)
(pCi/m 3 )
(pCi/kg, wet)
(pCi/L) wet)
H-3(1) 2 x 10' Mn-54 1 x 10i 3 x 10' Fe-59 4 x 102 1 x 10i Co-58 1 x 10, 3 x 10' Co-60 3 x 102 1 x 104 Zn-65 3 x 102 2 x 104 Zr-Nb-95 4 x 102 1-131 2
0.9 3
1 x 102 Cs-134 30 10 1 x 103 60 1 x 10, Cs-137 50 20 2 x 103 70 2 x 101 Ba-La-140 2 x 102 3 x 101 (1)
For drinking water samples.
The value given is the 40 CFR Part 141 value.
If no drinking water pathway exists, a value of 30,000 pCi/L may be used.
(2)
The limits are for samples that have only one radionuclide detected.
When a sample contains more than one radionuclide, the total level of radioactivity limit is concentration (1) reporting level (1) concentration (2) reporting level (2)
Columbia Generating Station 6.3.1-12 Amendment 35, MAR 2002
Radiological Environmental Monitoring Program 6.3.1 TABLE 6.3.1-3 DETECTION CAPABILITIES FOR ENVIRONMENTAL SAMPLE ANALYSIS(a)
LOWER LIMIT OF DETECTION (LLD)(b)(c)
AIRBORNE FOOD PARTICULATE FISH PRODUCTS SEDIMENT WATER OR GASES (pCi/kg.
MILK (pCi/kg, (pCi/kg, ANALYSIS (pCi/L)
(pCi/M 3 )
wet)
(pCi/L) wet) dry)
Gross beta 4
1 x 10.2 H-3 2000*
Mn-54 15 130 Fe-59 30 260 Co-58,60 15 130 Zn-65 30 260 Zr-95 15 Nb-95 15 1-131 7 x 10.2 1
60 Cs-134 15 5 x 102 130 15 60 150 Cs-137 18 6 x 102 150 18 80 180 Ba-140 15 15 La-140 15 15
(*)
If no drinking water pathway exists, a value of 3,000 pCi/L may be used.
(a)
This list does not mean that only these nuclides are to be considered.
Other peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Annual Radiological Environmental Operating Report.
(b)
Required detection capabilities for thermoluminescent dosimeters used for environmental measurements shall be in accordance with the recommendations of Regulatory Guide 4.13, except for specification regarding energy dependence.
Correction factors shall be provided for energy ranges not meeting the energy dependence specification.
(c)
The LLD is defined in the ODCM definitions section.
Analyses shall be performed in such a manner that the stated LLDs will be achieved under routine conditions.
Occasionally background fluctuations, unavoidable small sample sizes, the presence of interfering nuclides, or other uncontrollable circumstances may render these LLDs unachievable.
In such cases, the contributing factors shall be identified and described in the Annual Radiological Environmental Operating Report.
Columbia Generating Station 6.3.1-13 Amendment 35, MAR 2002
Land Use Census 6.3.2 6.3 RADIOLOGICAL ENVIRONMENTAL MONITORING 6.3.2 Land Use Census A Land Use Census shall be conducted and:
- a.
Shall identify the location of the nearest milk animal, residence, and garden of greater than 500 ft 2 producing broad leaf vegetation in each of the 16 meteorological sectors within a distance of 5 miles;
- b.
The calculated dose and dose commitment at each newly identified census location shall be less than the most recent values calculated by SR 6.2.2.3.1 at the previous census location.
APPLICABILITY:
At all times.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Land Use Census not A.1 Prepare and submit the Upon submittal conducted.
reasons for not of current conducting the Land Use calendar year OR Census and the Radiological corrective actions to Environmental All required locations prevent recurrence.
Operating Report not identified.
B.
One or more newly B.1 Identify new location(s)
Upon submittal identified census in the Radioactive of the current locations with the Effluent Release Report.
calendar year calculated dose or Radioactive dose commitment Effluent Release greater than the Report values calculated by SR 6.2.2.3.1 at the current census locations.
(continued)
Columbia Generating Station RFO 6.3.2 Amendment 35. MAR 2002
Land Use Census 6.3.2 COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME C.
One or more newly C.1 Add the new location to 30 days identified census the Radiological locations with the Environmental Monitoring calculated dose or Program.
dose commitment, via the same exposure AND
- pathway,
> 120% of the calculated dose or C.2 Delete the sampling After October 31 dose commitment from location having the of the year in the current sample lowest calculated dose which Land Use location identified in or dose commitment, via Census was Table 6.3.1-1.
the same exposure conducted pathway, from the Radiological Monitoring Program.
AND C.3 Identify the new Upon submittal location(s) in the of the current Radioactive Effluent calendar year Release Report, and the Radioactive revised figures and Effluent Release tables for the ODCM Report reflecting the new location.
SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.3.2.1 Conduct a Land Use Census during the Each calendar growing season by a door-to-door survey, year during the aerial survey, or by consulting local growing season agriculture authorities and report the results in the Annual Radiological Environmental Operating Report.
Columbia Generating Station 6.3.2-2 Amendment 35, MAR 2002
Interlaboratory Comparison Program 6.3.3 6.3 RADIOLOGICAL ENVIRONMENTAL MONITORING 6.3.3 Interlaboratory Comparison Program RFO 6.3.3 APPLICABILITY:
Analyses shall be performed on all radioactive materials supplied as part of an Interlaboratory Comparison Program approved by the NRC.
At all times.
COMPENSATORY MEASURES CONDITION REQUIRED COMPENSATORY MEASURE COMPLETION TIME A.
Requirements of RFO A.1 Prepare and submit, in Upon submittal 6.3.3 not met.
the Annual Radiological of current Environmental Operating calendar year Report, corrective Annual actions to prevent Radiological recurrence.
Environmental Operating Report SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 6.3.3.1 Perform analysis on all radioactive Annually material supplied as part of the Interlaboratory Comparison Program as described in the OCDM and submit the results in the next annual Radiological Environmental Operating Report.
Columbia Generating Station Amendment 35, MAR 2002 6.3.3-1
Annual Radiological Environmental Operating Report 6.4.1 6.4 REPORTING REQUIREMENTS 6.4.1 Annual Radiological Environmental Operating Report Routine Radiological Environmental Operating Reports covering the operation of the unit during the previous calendar year shall be submitted prior to May 15 of each year.
The Annual Radiological Environmental Operating Reports shall include summaries, interpretations, and an analysis of trends of the results of the radiological environmental surveillance activities for the report period, including a comparison with preoperational studies, with operational controls as appropriate, and with previous environmental surveillance reports, and an assessment of the observed impacts of the plant operation on the environment.
The reports shall also include the results of Land Use Censuses required by Requirement for OPERABILITY 6.3.2.
The Annual Radiological Environmental Operating Reports shall include the results of analysis of all radiological environmental samples and of all environmental radiation measurements taken during the period pursuant to the locations specified in the table and figures in the ODCM, as well as summarized and tabulated results of these analyses and measurements in the format of the table in the Radiological Assessment Branch Technical Position, Revision 1, November 1979.
In the event that some individual results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results.
The missing data shall be submitted as soon as possible in a supplementary report.
The reports shall also include the following:
a summary description of the radiological environmental monitoring program, at least two legible maps* covering all sampling locations keyed to a table giving distances and directions from the centerline of the reactor; the results of license participation in the Interlaboratory Comparison Program, required by Requirement for OPERABILITY 6.3.3: discussion of all deviations from the sampling schedule of Table 6.3.1-1; and discussion of all analyses in which the LLD required by Table 6.3.1-3 was not achievable.
- One map shall cover stations near the SITE BOUNDARY; a second shall include the more distant stations.
Columbia Generating Station 6.4.1-1 Amendment 35, MAR 2002
Radioactive Effluent Release Report 6.4.2 6.4 REPORTING REQUIREMENTS 6.4.2 Radioactive Effluent Release Report The routine Radioactive Effluent Release Report covering the operation of the unit shall be submitted within 60 days after January 1 of each year in accordance with 10 CFR 50.36a(a)(2).
The Radioactive Effluent Release Report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit as outlined in Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," Revision 1, June 1974, with data summarized on a quarterly basis following the format of Appendix B thereof.
The Radioactive Effluent Release Report shall include an annual summary of hourly meteorological data collected over the previous year.
This annual summary may be either in the form of an hour-by-hour listing on magnetic tape of wind speed, wind direction, atmospheric stability, and precipitation (if measured), or in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability.
This same report shall include an assessment of the radiation doses due to the radioactive liquid and gaseous effluents released from the unit or station during the previous calendar year.
This same report shall also include an assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY (ODCM Figure 3-1) during the report period.
All assumptions used in making these assessments, i.e., specific activity, exposure time and location, shall be included in these reports.
The meteorological conditions concurrent with the time of release of radioactive materials in gaseous effluents, as determined by sampling frequency and measurement, shall be used for determining the gaseous pathway doses.
The assessment of radiation doses shall be performed in accordance with the methodology and parameters in the ODCM.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 6.4.2-1
Radioactive Effluent Release Report 6.4.2 6.4.2 Radioactive Effluent Release Report (continued)
The Radioactive Effluent Release Report shall also include an assessment of radiation doses to the likely most exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources, including doses from primary effluent pathways and direct radiation, for the previous calendar year to show conformance with 40 CFR Part 190, Environmental Radiation Protection Standards for Nuclear Power Operation.
Acceptable methods for calculating the dose contribution from liquid and gaseous effluents are given in Regulatory Guide 1.109, Rev.
1, October 1977.
The Radioactive Effluent Release Report shall include a report of solid waste transported from the site during the year as specified by Regulatory Guide 1.2.1, Revision 1, June 1974, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water Cooled Nuclear Power Plants."
The Radioactive Effluent Release Reports shall include a list and description of unplanned releases from the site to UNRESTRICTED AREAS of radioactive materials in gaseous and liquid effluents made during the reporting period.
The Radioactive Effluent Release Reports shall include any changes made during the reporting period to the Process Control Program (PCP) and to the ODCM, as well as a listing of new locations for dose calculations and/or environmental monitoring identified by the Land Use Census pursuant to RFO 6.3.2.
Columbia Generating Station 6.4.2-2 Amendment 35, MAR 2002
Major Changes To Radioactive Liquid, Gaseous, and Solid Waste Treatment Systems 6.4.3 6.4 REPORTING REQUIREMENTS 6.4.3 Major Changes To Radioactive Liquid, Gaseous, and Solid Waste Treatment Systems*
Licensee initiated major changes to the radioactive waste systems (liquid, gaseous, and solid):
- a.
Shall be reported to the Commission in the Radioactive Effluent Release Report for the period in which the evaluation was reviewed by the POC.,
The discussion of each change shall contain:
- 1.
A summary of the evaluation that led to the determination that the change could be made without prior NRC approval;
- 2.
Sufficient detailed information to totally support the reason for the change without benefit of additional or supplemental information;
- 3.
A detailed description of the equipment, components, and processes involved and the interface with other plant systems;
- 4.
An evaluation of the change, which shows the predicted releases of radioactive materials in liquid and gaseous effluents and/or quantity of solid waste that differ from those previously predicted in the license application and amendments thereto;
- 5.
An evaluation of the change, which shows the expected maximum exposures to a MEMBER OF THE PUBLIC in the UNRESTRICTED AREA and to the general population that differ from those previously estimated in the license application and amendments thereto; (continued)
Columbia Generating Station Amendment 35, MAR 2002 6.4.3-1
Major Changes To Radioactive Liquid, Gaseous, and Solid Waste Treatment Systems 6.4.3 6.4.3 Major Changes To Radioactive Liquid, Gaseous, And Solid Waste Treatment Systems*
(continued)
- 6.
A comparison of the predicted releases of radioactive materials, in liquid and gaseous effluents and in solid waste, to the actual releases for the period prior to when the changes are to be made;
- 7.
An estimate of the exposure to plant operating personnel as a result of the change; and
- 8.
Documentation of the fact that the change was reviewed and found acceptable by the POC.
- b.
Shall become effective upon review and acceptance by the POC.
- Licensees may choose to submit the information called for in this specification as part of the periodic FSAR update.
Columbia Generating Station 6.4.3-2 Amendment 35, MAR 2002
ODCM APPENDIX COLUMBIA GENERATING STATION Bases For Radiological Effluent And Radiological Environmental Monitoring Controls
Radioactive Liquid Effluent Monitoring Instrumentation B 6.1.1 B 6.1 INSTRUMENTATION B 6.1.1 Radioactive Liquid Effluent Monitoring Instrumentation BASES BACKGROUND APPLICABLE SAFETY ANALYSES REOUIREMENTS FOR OPERABILITY The radioactive liquid effluent monitoring instrumentation is provided to monitor and control, as applicable, releases of radioactive material in liquid effluents during normal plant operation.
They are also provided to monitor potential releases from anticipated operational transients.
These instruments are required by General Design Criteria 60, 63, and 64 of Ref. 1.
Setpoints for these instruments are established by the methodology of ODCM Section 2.0 to ensure compliance with the limits of Ref. 2.
Specific requirements for this instrumentation are provided in the Radiological Effluent Technical Specifications for BWRs (Ref.
3).
Additional guidance is provided in Refs. 4 and 5.
The radioactive liquid effluent monitoring instrumentation provides assurance that radioactive releases resulting from normal operation and any potential radioactive releases caused by Anticipated Operational Transients are monitored.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 6) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased radioactive liquid effluent releases.
Additional information on the Radioactive Liquid Process and Effluent Radiation Monitoring System can be found in Ref.
- 7.
The liquid process and effluent radiation monitors are listed in Ref.
8.
- 1. Liquid Radwaste Effluent Line Gross Radioactivity Monitor This monitor measures the radioactivity in the liquid effluent prior to its entering the cooling tower blowdown line.
All radioactive liquid effluent passes through this four inch line.
The detector has seven decades of range and has a sensitivity of 1OE-6 uCi/cc for Cs-137.
This monitor will automatically close a valve stopping the effluent release if its setpoint is exceeded.
Ref. 9 provides additional information on this monitor.
(continued)
Columbia Generating Station B 6.1.1-1 Amendment 35, MAR 2002
Radioactive Liquid Effluent Monitoring Instrumentation B 6.1.1 BASES REQUIREMENTS
- 2. Deleted FOR OPERABILITY (continued)
- 3. Turbine Service Water (TSW)
System Gross Radioactivity Monitor The TSW system provides for the removal of heat from balance of plant auxiliary equipment (Ref.
11).
It is normally a non-radioactive system but it has the potential to become contaminated because it provides cooling to some reactor auxiliary systems.
This radioactivity monitor is provided to detect that off-normal condition by monitoring for radioactivity in the TSW return header to the Circulating Water System.
The monitor is located on the 441' level of the turbine building.
The readout meter and recorder is located in the main control room panel BD-RAD-24.
If the setpoint is exceeded, an alarm will activate in the main control room.
The control room operator can then evaluate and take action to terminate the discharge and mitigate any uncontrolled release of radioactive material.
Ref.
12 provides additional information on this subsystem.
- 4. Standby Service Water (SW)
System Gross Radioactivity Monitor The Standby Service Water System provides cooling to the reactor during normal shutdown conditions.
It also provides cooling of the reactor during emergency conditions (Ref.
13).
The SW system has the potential to become contaminated because of its interface with the heat exchangers that cool the reactor.
This radiation monitor is provided to detect any increase in radioactivity in the system.
The Standby Service Water Monitors are located on the 501 and 522 foot level of the reactor building.
The meter is located in the main control room on panel P-604.
If the setpoint is exceeded, an alarm will activate in the main control room.
The control room operator can then evaluate and take action to terminate the discharge and mitigate any uncontrolled release of radioactive material.
Reference 14 provides further information on this subsystem.
(continued)
Columbia Generating Station B 6.1.1-2 Amendment 36, June 2002
Radioactive Liquid Effluent Monitoring Instrumentation Radioactive Liquid Effluent Monitoring Instrumentation B 6.1.1 BASES REQUIREMENTS
- 5. Liquid Radwaste Effluent Line Flow Rate Monitor FOR OPERABILITY (continued)
This flow rate monitor measures the flow of effluent from the Liquid Waste Management System.
This flow is variable from zero to 190 gpm.
The flow rate recorder is located in the radwaste control room.
Two displays of flow are provided:
the red pen spans a flow rate from zero to 270 gpm and the green pen from zero to 35 gpm.
- 6. Plant Discharge Blowdown Line Flow Rate Monitor This instrument measures the flow in the circulating water (CW) blowdown line.
Water from the CW system is returned to the Columbia River in order to prevent the buildup of dissolved solids in the cooling water.
This flow is recorded (range 0 - 7500 gpm) in the main control room.
The radioactive liquid effluent from the plant is normally mixed with this blowdown flow to provide dilution before release into the river (Ref.
15).
- 7. Alarm/Trip Setpoints For function 1 the set point is adjusted based on the material to be released.
The monitor is set to ensure the concentration limits of RFO 6.2.1.1 are not exceeded during the release.
The setpoint is adjusted to make sure the release into the Columbia River is below the required limits taking into account the amount of radioactivity in the batch being released and the dilution flow in the blowdown line.
For Functions 2 through 4 the alarm/trip setpoints are based on Ref.
2 limits.
To ensure these limits are never exceeded, the alarm setpoint shall be established at 80% or less of the maximum setpoint plus background.
This setpoint corresponds to a Cs-137 concentration of 8E-6 pCi/ml.
Functions 5 and 6 are record only and have no setpoints.
A record of the flow is important to verify dilution parameters.
(continued)
Columbia Generating Station B 6.1.1-31 Amendment 36, June 2002
Radioactive Liquid Effluent Monitoring Instrumentation B 6.1.1 BASES APPLICABILITY Gross radioactivity monitors on the Standby Service Water (SSW)
System and Turbine Service Water (TSW)
System are required to be in service when there is flow in the respective system.
The SSW monitors are not required to be operable when there is no flow in the SSW system.
Similarly, when there is no flow in the TSW system, the TSW radioactivity monitors are not required to be operable.
Without flow, the monitors are not able to detect leakage.
The Liquid Radwaste Effluent Line Gross Radioactivity Monitor and its corresponding Liquid Radwaste Effluent Line Flow Rate Monitor and the Plant Discharge Blowdown Line Flow Rate Monitor are only required when radioactive effluents are being discharged through this pathway.
COMPENSATORY MEASURES A.1, B.1, B.2, B.3, and E.1 These Compensatory Measures give the actions required to be taken if Le Liquid Radwaste Effluent Line Gross Radioactivity Monitor (Function 1) is inoperable and batch releases are to continue.
Two independent samples must be taken and analyzed from the batch to be released.
The calculations and valve lineups must be verified by two qualified members of the technical staff.
These actions are necessary to provide assurance that a controlled release can occur wil,,.i inoperable monitor.
If the monitor is not restored Lu operable status in 30 days this must be reported in the Radioactive Effluent Release Report.
This provides the NRC wit information on the status of inoperable equipment.
(continued)
Columbia Generating Station B 6.1.1-4 Amendment 37, January 2003
Radioactive Liquid Effluent Monitoring Instrumentation S,
B 6.1.1 BASES COMPENSATORY MEASURES (continued)
A.I.
C.I. C.2. and E.1 These Compensatory Measures are required to be taken if the
- TSW, or SW Gross Radioactivity Monitors (Functions 3, and 4) are inoperable.
Grab samples are required to be taken and analyzed every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> frequency provides an adequate indication of the trend of radioactivity in these locations when the monitor is not OPERABLE.
The channel instrument must also be restored to OPERABLE status within 30 days.
The 30 day limit provides an acceptable risk for this loss of monitoring condition.
If the monitor is not restored to OPERABLE status in 30 days this must be reported in the Radioactive Effluent Release Report.
A.1, D.1, D.2, and E.1 These Compensatory Measures are associated with the Liquid Radwaste Effluent Line and Plant Discharge Line Flow Rates.
These flow rates are required to determine the concentration of the effluents released.
If the Liquid Radwaste Effluent Flow Monitor is not OPERABLE and a release is to occur the flow must be estimated.
This is done by observing the level in the tank being pumped initially and every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
The combination of tank level and time can be used to estimate the flow.
If the Plant Discharge Blowdown Line Flow Rate Monitor is not OPERABLE during a radioactive release this must also be estimated.
Methods of estimating this flow rate using pump differential pressure are given in plant procedures.
A release can occur with no dilution from the blowdown line if the concentration of radioactivity being releases is low enough to meet limits without dilution.
SURVEILLANCE SR 6.1.1.1 REQUIREMENTS A CHANNEL CHECK is required every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when a monitor is required to be functional.
The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time interval provides assurance that the instrument will perform its function if needed.
(continued)
Columbia Generating Station I
B 6.1.1-5 Amendment 36, June 2002
Radioactive Liquid Effluent Monitoring Instrumentation B 6.1.1 BASES SURVEILLANCE SR 6.1.1.1 (continued)
REOUIREMENTS A CHANNEL CHECK for the flow instruments associated with a batch release is required before a radioactive release and every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter until the release is complete.
This ensures the flow instruments are operational prior to and during a batch release.
SR 6.1.1.2 The Liquid Radwaste Effluent Line Monitor is used for batch releases and a SOURCE CHECK must be performed prior to each release.
This provides increased confidence that the instrument will operate as required to prevent further releases if its trip setpoint is exceeded.
SR 6.1.1.3 A SOURCE CHECK is required monthly to ensure all gross radioactivity monitors are functional.
The monthly interval provides adequate reliability of instrument operation if needed to perform its function.
SR 6.1.1.4 A CHANNEL FUNCTIONAL TEST is required on all Radioactive Liquid Monitoring Instrumentation listed on Table 6.1.1-1 quarterly.
This test interval is adequate to ensure the instrument will perform its complete function.
The CHANNEL FUNCTIONAL TEST for the Liquid Radwaste Effluent Line must demonstrate automatic isolation of the effluent pathway.
(continued)
Columbia Generating StatioB B 6.1.1-6 Amendment 36, June 2002
Radioactive Liquid Effluent Monitoring Instrumentation Radioactive Liquid Effluent Monitoring Instrumentation B 6.1.1 BASES SURVEILLANCE SR 6.1.1.4 (continued)
REOUIREMENTS The CHANNEL FUNCTIONAL TEST for all gross radioactivity monitors must demonstrate that control room annunciation occurs if the:
a) instrument indicates measured levels above the alarm
- setpoint, b) high voltage abnormally low, and c) instrument indicates downscale failure.
These tests are required to provide assurance of channel operation.
In addition, the Liquid Radwaste Effluent Line and SW Gross Radioactivity Monitors must demonstrate control room alarm annunciation if the instrument controls are not set in the operate mode.
This test provides increased assurance that the plant operator are aware of an inoperable instrument.
SR 6.1.1.5 A CHANNEL CALIBRATION shall be performed on all Radioactive Liquid Monitoring Instrumentation listed on Table 6.1.1-1 every 18 months.
This time interval provides adequate protection against drift and other changes in the instrument performance.
For the gross radioactivity monitors the initial CHANNEL CALIBRATION shall be performed using one or more reference standards certified by the National Institute of Science and Technology (NIST) or using standards that have been obtained from suppliers that participate in measurement assurance activities with NIST.
These standards shall permit calibrating the system.
For subsequent CHANNEL CALIBRATION, sources that have been related to the initial calibration shall be used.
These standards provide assurance of instrument accuracy.
(continued)
Columbia Generating Station Amendment 36, June 2002 B 6.1.1-7
Radioactive Liquid Effluent Monitoring Instrumentation B 6.1.1 BASES REFERENCES 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
- 9.
- 10.
- 11.
- 12.
- 13.
- 14.
15.
10 CFR 20.1001-20.2402.
NUREG-0473, Revision 2.
NUREG-1302 FSAR Section 15.0.3.
FSAR Section 11.5.2.2.2.
FSAR Table 11.5-2.
FSAR Section 11.5.2.2.2.3.
FSAR Section 11.5.2.2.2.5.
FSAR Section 9.2.1.
FSAR Section 11.5.2.2.2.4.
FSAR Section 9.2.7.
FSAR Section 11.5.2.1.4.
FSAR Section 11.2.3.1.
Columbia Generating Station B 6.1.1-8 Amendment 36, June 2002
Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 B 6.1 INSTRUMENTATION B 6.1.2 Radioactive Gaseous Effluent Monitoring Instrumentation BASES BACKGROUND APPLICABLE SAFETY ANALYSES REOUIREMENTS FOR OPERABILITY The radioactive gaseous effluent monitoring instrumentation is provided to monitor and control, as applicable, releases of radioactive material in gaseous effluents.
These instruments are required by General Design Criteria 60, 63, and 64 of Ref. 1. Setpoints for these instruments are established by the methodology of ODCM Section 3.0 to ensure compliance with the limits of Ref. 2.
Specific requirements for this instrumentation are provided in the Radiological Effluent Technical Specifications for BWRs (Ref.
3).
Additional guidance is provided in Refs.
4 and 5.
The radioactive gaseous effluent monitoring instrumentation provides assurance that radioactive releases resulting from normal operation and any potential radioactive releases caused by Anticipated Operational Transients are monitored.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 6) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased gaseous effluent releases.
The FSAR (Ref.
- 7) provides additional information on the Gaseous Process and Effluent Radiation Monitoring System.
Ref.
8 provides additional detail on the Gaseous Process and Effluent Radiation Monitors.
- 1. Main Condenser Offqas Post-Treatment Radiation Monitors Two monitors measure the radioactivity in the offgas piping downstream of the off gas system charcoal vessels and upstream of the offgas system discharge valve.
The purpose of these radiation monitors is to provide information on the amount of gamma radiation in the offgas process stream after treatment and to automatically isolate the offgas system or to automatically initiate offgas treatment if the system is being operated in the bypass mode.
Radiation is measured by a GM detector and countrate meters display the results in the main control room.
An auxiliary trip unit uses the signal from these two detectors to isolate the charcoal system if the logic is satisfied by a combination of high-(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.1.2-1
Radioactive Gaseous Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES REQUIREMENTS
- 1. Main Condenser Offqas Post-Treatment Radiation Monitors FOR OPERABILITY (continued) high-high radiation and downscale trips.
This is the normal Mode of operation with the charcoal beds in service.
Another trip signal from these monitors initiates opening of the charcoal absorber treatment valve and closure of the bypass valve if the system is being run in the bypass mode during plant startup.
Alarms are provided in the main control room that show monitor system status.
Further information on the subsystem can be found in Ref.
- 9.
- 2. Main Condenser Offqas Pre-Treatment Radiation Monitor This monitor is located at the outlet of the water separator downstream of the catalytic recombiners.
The monitor measures the radioactivity due to fission gases and activation products produced in the reactor and transported with the steam through the turbine to the condenser.
The purpose of inis monitor is to provide the main control room with information on the amount of gamma radioactivity in the untreated offgas stream.
The detector is a gamma-sensitive ion chamber.
Trip outputs are used for alarm only.
Further information on this subsystem can be found in Ref.
- 10.
2a. Mechanical Vacuum Pump Discharge Radiation Monitor This Geiyg:,Aeller type radiation monitor is designed to alarm, stop, and isolate the mechanical vacuum pumps in the event of or_-i levels of radioactive gases in the air being exhausted f,,*i the condenser.
The mechanical vacuum pumps are operated during plant start-ups to remove bulk air from the condenser.
They are stopped when the steam jet air ejectors are put into service.
Further information on this radiation monitoring system can be found in Ref.
- 11.
- 3. Reactor Building Elevated Discharge Radiation Monitor This monitoring system measures radioactivity in the reactor building elevated release duct from the a)
Offgas effluent, b) the gland seal system, (continued)
Columbia Generating Station B 6.1.2-2 Amendment 35, MAR 2002
Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES REQUIREMENTS
- 3. Reactor Building Elevated Discharge Radioactivity Monitor FOR OPERABILITY (continued) c)
Mechanical vacuum pump, d) the Standby Gas Treatment System, and e) the exhaust air from the Reactor Building Ventilation System.
The purpose of this monitoring subsystem is to characterize the radioactivity being released through the reactor building elevated discharge vent and to provide alarms in the event of abnormal operation.
The monitor has no control function but an alarm is provided in the control room if the setpoint is exceeded.
A continuous representative sample is extracted from the elevated release duct through an isokinetic probe.
The sample is filtered to collect particulates and passes through an impregnated charcoal cartridge to collect iodine.
The sample travels through a flow indicator that provides flow rate and totalized flow.
Both the sample flow rate and the exhaust duct flow rate and their totalized flow are recorded and alarmed in the control room.
These samples are collected and analyzed per SR 6.2.2.1.2 and Table 6.2.2.1-1.
Further information on this subsystem can be found in Ref.
- 12.
Footnote (b) is intended to address the condition when neither the Reactor Building Ventilation System nor the Standby Gas Treatment System is operating.
If there is no flow through the elevated discharge point this monitor is not OPERABLE and the Compensatory Measures are also not effective.
The reactor building is a confinement structure which acts as a secondary containment so leakage of radioactive material should be limited.
Under these no effluent flow conditions building ambient air samples, building equipment status, including the identification of possible sources of radioactivity, and meteorological data (continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.1.2-3
Radioactive Gaseous Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES REQUIREMENTS
- 3. Reactor Building Elevated Discharge Radioactivity Monitor FOR OPERABILITY (continued) can be used to estimate the out-leakage from the building.
The Technical Specifications place severe limits on the amount of time that can be spent without secondary containment so this condition is not likely to persist for any length of time.
- 4. Turbine Building Exhaust Radiation Monitor This monitoring system measures radioactivity in the turbine building exhaust.
The monitor detects fission and activation products from the steam which may leak from the turbine or other equipment in the building.
The purpose of this monitoring subsystem is to characterize the radioactivity being released through the turbine building discharge vent and to provide alarms in the event of abnormal operation.
The monitor is read and recorded in the main control room.
An alarm is provided in the control room if the setpoint is exceeded.
A continuous representative sample is extracted from the exhaust duct through an multi-ported isokinetic probe.
The sample is filtered to collect particulates and passes through an impregnated charcoal cartridge to collect iodine.
Both the sample flow rate and the exhaust duct flow rate are recorded and alarmed in the control room.
These samples are collected and analyzed per SR 6.2.2.1.2 and Table 6.2.2.1-1.
Further information on this subsystem can be found in Ref.
- 13.
Footnote (b) is intended to address the condition when the Turbine Building Ventilation System is not operating.
If there is no flow through the turbine building exhaust this monitor is not OPERABLE and the Compensatory Measures are also not effective.
The turbine building is a conventional steel structure so leakage of radioactive material could be significant.
Under these conditions building ambient air samples, building equipment status including potential radioactivity sources, and meteorological data can be used to estimate the out-leakage from the building.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.1.2-4
Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES REQUIREMENTS FOR OPERABILITY (continued)
- 5.
Radwaste Building Ventilation Exhaust Radiation Monitor This monitoring system measures radioactivity in the radwaste building ventilation air exhaust.
Radioactivity originates from radwaste tank vents, processing equipment, sampling hoods, as well as from process treatment systems within the building.
The purpose of this monitoring subsystem is to characterize the radioactivity being released through radwaste building discharge vent and to provide alarms in the event of abnormal operation.
The monitor is read and recorded in the main control room.
An alarm is provided in the control room if the setpoint is exceeded.
A continuous sample is extracted from the exhaust duct, through a multi-ported isokinetic probe.
The sample is filtered to collect particulates and passes through an impregnated charcoal cartridge to collect iodine.
These samples are collected and analyzed per SR 6.2.2.1.2 and Table 6.2.2.1-1.
Further information on this subsystem can be found in Ref.
- 14.
Footnote (b) is intended to address the condition when the Radwaste Building Ventilation System is not operating.
If there is no flow through the radwaste building exhaust this monitor is not OPERABLE and the Compensatory Measures are also not effective.
Under these conditions building ambient air samples, building equipment status including potential radioactive sources, and meteorological data can be used to estimated the out-leakage from the building.
- 6. Alarm/Trio SetDoints The Function 1 monitors are normally operated in the mode where they are monitoring the output of the gaseous effluent stream from the charcoal beds.
Under these conditions a High-High-High Radiation signal from both monitors initiates closure of OG-V-60 terminating the effluent release.
The setpoints are established to assure the valve will be closed before the site boundary dose rate criteria is exceeded.
A downscale trip of both monitors or a combination of downscale trip and High-High-High radiation will also cause (continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.1.2-5
Radioactive Gaseous Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES REQUIREMENTS
- 6. Alarm/Trip Setpoints (continued)
FOR OPERABILITY isolation of the effluent release.
The Function 1 monitors can also be operated in the mode where the charcoal beds are being bypassed.
In this case a High radiation trip from either monitor will cause closure of the bypass valve, OG-V
- 45.
Prior to placing the gaseous radwaste treatment system in the charcoal bypass mode, the alarm setpoints on the main plant vent release monitor shall be set to account for the increased percentages of short-lived noble gases.
Noble gas percentages shall be based either on actual measured values or on primary coolant design base noble gas concentration percentages adjusted for 30-minute decay.
Table 3-15 lists the percentage values for 30-minute decay.
The setpoint for this action is well below the site boundary dose rate criteria.
Control room alarms are provided for a downscale condition, High Radiation, and High-High-High Radiation.
The Function 2, High Radiation alarm setpoint is required to be set at 1.5 times the steady state full power nominal radiation level per Ref. 15.
This provides assurance that the control room will be aware of increasing radiation levels in the untreated gaseous effluent stream from the main condenser.
A second High-High Radiation alarm is provided giving the control room indication if the level continues to rise.
The Function 2a, 3a, 4a, and 5a monitors have their setpoints established in a manner that assures the instantaneous dose rate limits to the unrestricted area are less than the limits given in RFO 6.2.2.1.
ODCM Section 3.4 provides the methodology for establishing these setpoints.
The calculations take into account the partition of the limiting dose rate between the three release points.
The maximum normalized diffusion coefficient (XWO) at and beyond the site boundary is used to model the decrease in radionuclide concentration between the point of release and the receptor location.
Both whole body and skin dose setpoints are calculated and the lower setpoint is used for the instrument.
The dose rate limits are provided in Ref. 2.
(continued)
Columbia Generating Station B 6.1.2-6 Amendment 35, MAR 2002
Radioactive Gaseous Effluent Monitoring Instrumentation 1-1i B 6.1.2 BASES REQUIREMENTS FOR OPERABILITY
- 6.
Alarm/Trip Setpoints (continued)
Functions 3b, 3c, 4b, 4c, 5b, and 5c do not have established setpoints.
These functions collect iodine and particulate samples for further analysis and no setpoints are associated with these activities.
It is not considered to be practicable to apply instantaneous alarm/trip setpoints to integrating radiation monitors sensitive to radioiodines or radioactive materials in particulate form.
Functions 3d, 4d, and 5d are associated with the flow rate of effluent from the three buildings.
Design ventilation rates are given in Ref.
- 16.
These setpoints are established to provide the plant operators with an alarm indicating abnormal flow conditions.
Functions 3e, 4e, and 5e are associated with flow rate in the iodine and particulate sampling devices.
The flow through these filters must be maintained to obtain a representative sample.
Setpoints are established to provide plant operators with an alarm if the sample flow fails to register the required value.
Further guidance on setpoint determination can be found in Ref.
4.
APPLICABILITY The Main Condenser Offgas Post-Treatment and Pre-Treatment Monitors are required to be OPERABLE when the steam jet air ejectors are put into operation.
Prior to this time condenser offgas is exhausted by the mechanical vacuum pump.
The Mechanical Vacuum Pump Radiation Monitor is required to be OPERABLE when the Mechanical Vacuum Pumps are being used to create and maintain a condenser vacuum and there is a
potential for radioactive release from the condenser area.
During startup and shutdown when vacuum is being maintained with a Mechanical Vacuum Pump and the Steam Seal System is operational the Mechanical Vacuum Pump Radiation Monitor must be OPERABLE.
All other instruments are required to be OPERABLE when there is exhaust flow through the building exhaust vent.
If there is no flow through the exhaust, the monitors do not provide any useful information.
in this case footnote (b) of Table 6.1.2-1 shall be followed to prevent an unmonitored release condition.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.1.2-7
Radioactive Gaseous Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES COMPENSATORY Separate entry is allowed for each channel.
The note allows MEASURES a Condition to be entered separately for each inoperable instrument and completion times tracked on a per instrument basis.
A.1 and B.1 This Compensatory Measure gives the action required if the Mechanical Vacuum Pump Radiation Monitor is not OPERABLE when it is required.
The Reactor Building Elevated Discharge Radiation Monitor monitors the effluent pumped from the condenser by the Mechanical Vacuum Pump.
If the Reactor Building Elevated Discharge Radiation Monitor is OPERABLE this provides adequate assurance that potential releases will be monitored.
If this monitor is also INOPERABLE then sampling is required.
A.1, C.1, C.2. C.3, and F.1 The Compensatory Measures give the actions required to be taken if the Main Condenser Offgas Post-Treatment Radiation Monitor, the Reactor Building Elevated Discharge Low Range Activity Monitor, the Turbine Building Ventilation Exhaust Noble Gas Activity Monitors, or the Radwaste Building Ventilate
- v>haust Noble Gas Activity Monitors are inoperab.
I grab sample must be taken at the associated sample location within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and every 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter.
The grab >Dole must be analyzed for noble gas gamma emmiters within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after the sample is taken.
This sampling and analysis provides adequate assurance that the noble gases being released are characterized.
If the channel is not restored to OPERABLE status in 30 days, the event must be reported to the NRC in the calendar year Radioactive Effluent Release Report.
This allows the NRC to monitor equipment that has been inoperable for an extended time period.
(continued)
Columbia Generating Station B 6.1.2-8 Amendment 35, MAR 2002
Radioactive Gaseous Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES COMPENSATORY A.1, D.1, D.2, and F.1 MEASURES (continued)
These COMPENSATORY MEASURES are required to be taken if the Effluent Flow Rate Monitors in the Reactor Building Elevated Discharge, the Turbine Building Ventilation Exhaust, or the Radwaste Building Ventilation Exhaust are INOPERABLE.
An estimate of the flow rate from the associated building is required every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
An estimate of the flow can be obtained by noting the number of fans in operation.
These same COMPENSATORY MEASURES are also required to be taken if associated building Iodine and Particulate Sampler Flow Rate Monitors are INOPERABLE.
If the Sampler Flow Rate Monitors are out of service auxiliary sampling equipment is used to provide sample flow.
The operation of the sampling equipment and sample flow is recorded every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
If any flow related channel above is not restored to OPERABLE status in 30 days the event must be reported to the NRC in the calendar year Radioactive Effluent Release Report.
This allows the NRC to monitor equipment that has been inoperable for an extended time period.
A.1, E.1, E.2, E.3, and F.1 These Compensatory Measures are required to be taken if the Iodine and Particulate Samplers associated with the Reactor Building Elevated Discharge, the Turbine Building Ventilation Exhaust, or the Radwaste Building Ventilation Exhaust are inoperable.
Auxiliary sampling equipment is used to collect samples from the associated effluent release pathway within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
This auxiliary sampler is to be used continuously to provide a sample for later analysis.
Compensatory Measure E.2 can be used if auxiliary sampling is not available.
Relevant information should be collected to characterize the particulate and iodine effluent releases during the period of time the auxiliary sampling equipment was not available when required by Compensatory Measure E.I.
If Compensatory Measure E.2 is used this must be reported to the NRC upon submittal of the current calendar year Radioactive Effluent Release Report.
(continued)
Columbia Generating Station B 6.1.2-9 Amendment 35, MAR 2002
Radioactive Gaseous Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES COMPENSATORY A.1, G.1, G.2, G.3 and H.1 MEASURES (continued)
If the normal sampling equipment is not restored to OPERABLE status in 30 days the event must be reported to the NRC in the calendar year Radioactive Effluent Release Report.
This allows the NRC to monitor equipment that has been inoperable for an extended time period.
These Compensatory Measures are associated with the Main Condenser Offgas Pre-Treatment Radiation Monitor.
If this monitor is inoperable immediate action must be taken to verify the Offgas Treatment System (RECHAR) is in operation.
Within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> a temporary Area Radiation Monitor (ARM) shall be put in place to monitor pre-treatment radiation levels.
The operation of the ARM is verified every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
Efforts must be made to restore the Main Condenser Offgas Pre-Treatment Radiation Monitor to OPERABLE status in 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.
If this is not done, the plant must be in Hot Standby within the following 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
Plant shutdown is required because continuous monitoring of the pre-treatment radiation level provides a direct indication of the condition of the reactor fuel.
Continued power operation beyond 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is not allowed.
SURVEILLANCE SR 6.1.2.1 REOUIREMENTS A CHANNEL CHECK is required every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for the gamma and flow rate monitors.
The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time interval provides assurance that the instrument will perform its function if needed.
A CHANNEL CHECK for the Main Condenser Offgas Post Treatment and Pre-Treatment Radiation Monitors is required every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the Steam Jet Air Ejectors are in operation.
A CHANNEL CHECK of the building noble gas gamma monitors is required every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> at all times.
For the building flow rate instruments, a CHANNEL CHECK is required every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the associated building exhaust system is operational.
The CHANNEL CHECK for the Radwaste Building Effluent System Flow Rate Monitor shall be performed by comparing a computer reading or power signal comparing each fan's local amperage reading with pre-established baseline values.
(continued)
Columbia Generating Station B 6.1.2-10 Amendment 35, MAR 2002
Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES SURVEILLANCE SR 6.1.2.2 REQUIREMENTS (continued)
A daily SOURCE CHECK is required for the Main Condenser Offgas Post-Treatment Radiation Monitors.
This provides increased confidence that the instruments will operate as required to detect excess gamma radioactivity in the treated gas process stream.
This test is required whenever the steam jet air ejectors are in operation.
SR 6.1.2.3 A CHANNEL CHECK for the iodine and particulate samplers is required weekly.
The change-out of the filters is considered the equivalent of a CHANNEL CHECK.
The weekly check of sampler operation is sufficient to provide assurance of a quality sample for analysis.
This CHANNEL CHECK is required at all times.
SR 6.1.2.4 The monthly SOURCE CHECK is required for the Main Condenser Offgas Pre-Treatment Monitor whenever the steam jet air ejectors are in operation.
A monthly SOURCE CHECK is also required for the Reactor Building Elevated Discharge Low Range Activity Monitor, the Turbine Building Ventilation Exhaust Noble Gas Activity Monitor, and the Radwaste Building Ventilation Exhaust Noble Gas Activity Monitor.
The building effluent noble gas gamma monitors require a source check at all times.
The monthly SOURCE CHECK provides adequate assurance of channel OPERABILITY.
SR 6.1.2.5 A CHANNEL FUNCTIONAL TEST is required for all instruments except the iodine and particulate samplers and the Mechanical Vacuum Pump Discharge Radiation Monitor quarterly or every 92 days.
This test frequency provides adequate assurance of the channel function.
A CHANNEL FUNCTIONAL TEST is not required for the samplers as the routine analysis of the samples provides assurance of sample function.
The CHANNEL FUNCTIONAL TEST for the Main (conti nued) rnimhin annortiinn Statinn R 6.1.2-11 Amendment 35. MAR 2002
- .*U I I..llllU I U U*II*I lll*
b*
- I vl*
Radioactive Gaseous Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES SURVEILLANCE SR 6.1.2.5 (continued)
REQUIREMENTS Condenser Offgas Post and Pre-Treatment Monitors, the Reactor Building Elevated Discharge Low Range Noble Gas Monitor require a demonstration that control room alarm annunciation occurs if:
a) the instrument indicates measured levels above the alarm setpoint, and b) circuit failure occurs.
The CHANNEL FUNCTIONAL TEST for the Turbine Building Ventilation Exhaust and Radwaste Building Ventilation Exhaust Noble Gas Monitors must demonstrate that circuit failures or instrument controls when set in the off position produce control room alarm annunciation.
The CHANNEL FUNCTION TEST for the Radwaste Building Ventilation Exhaust Effluent System Flow Rate Monitor shall be performed by measurement of the phase currents for each fan.
SR 6.1.2.5a A CHANNEL CHECK of the Mechanical Vacuum Pump Radiation Monitor is required prior to its use.
This check is required only if it has not been performed during the past 30 days.
During shutdowns this check can be performed by verifying that the instrument was on-scale prior to shutdown.
SR 6.1.2.6 A CHANNEL CALIBRATION is required for all instruments except the iodine and particulate samplers and the Mechanical Vacuum Pump Discharge Radiation Monitor every 18 months.
This test frequency provides adequate protection against drift or other instrument inaccuracies.
The CHANNEL CALIBRATION is not required for the samplers as the routine analysis of the samples provides assurance of sample integrity.
The CHANNEL CALIBRATION of the Main Condenser Offgas Post and Pre-Treatment Monitors, the Reactor Building Elevated Discharge Low Range Activity Monitor, and the (continued)
Columbia Generating Station B 6.1.2-12 Amendment 35, MAR 2002
Radioactive Gaseous Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES SURVEILLANCE SR 6.1.2.6 (continued)
REQUIREMENTS Turbine and Radwaste Building Low Range Noble Gas Activity Monitors have special requirements.
For these gross radioactivity monitors the initial CHANNEL CALIBRATION shall be performed using one or more reference standards traceable to the National Institute of Science and Technology (NIST) or using standards that have been obtained from suppliers that participate in measurement assurance activities with NIST.
These standards shall permit calibrating the system over its intended range of energy and monitor response.
Subsequent CHANNEL CALIBRATION shall be performed using the equivalent quality and radioactive sources that have been related to the initial calibration.
The CHANNEL CALIBRATION for the Radwaste Building Ventilation Effluent System Flow Rate Monitor shall be performed by using a flow measurement device to determine the fan current to flow relationship.
SR 6.1.2.7 The CHANNEL CALIBRATION for the Mechanical Vacuum Pump Discharge Radiation Monitor is required during refueling outages.
This longer frequency is acceptable since this monitor is backed up by the Reactor Building Elevated Discharge Radiation Monitor.
REFERENCES
- 1.
- 2.
10 CFR 20.1-20.602.
- 3.
NUREG-0473, Revision 2.
- 4.
- 5.
- 6.
FSAR Section 15.0.3.
- 7.
FSAR Section 11.5.2.2.1.
- 8.
FSAR Table 11.5-1.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.1.2-13
Radioactive Gaseous Effluent Monitoring Instrumentation B 6.1.2 BASES REFERENCES (continued)
- 9.
- 10.
- 11.
- 12.
- 13.
- 14.
- 15.
16.
FSAR Section 11.5.2.2.1.2.
FSAR Section 11.5.2.2.1.1.
FSAR Section 11.5.2.2.1.4.
FSAR Section 11.5.2.2.1.5.
FSAR Section 11.5.2.2.1.6.
FSAR Section 11.5.2.2.1.7.
Technical Specification Amendment 112 (G12-93-028).
FSAR Table 11.3-8.
Columbia Generating Station B 6.1.2-14 Amendment 35, MAR 2002
Liquid Concentration B 6.2.1.1 B 6.2 RADIOACTIVE EFFLUENTS B 6.2.1 Liquid Effluents B 6.2.1.1 Liquid Concentration BASES BACKGROUND APPLICABLE SAFETY ANALYSES REOUIREMENTS FOR OPERABILITY APPLICABILITY This RFO is focused on the concentration of radionuclides released to the Columbia River.
The radionuclide concentrations shall not exceed 10 times those given in Appendix B, Table 2, Column 2 of Ref. 1.
The RFO also implements the requirements of Technical Specification 5.5.4.b.
The radionuclide concentration limits provide assurance that any liquid radioactive releases caused by normal operation and Anticipated Operational Transients result in very low exposures to the general public.
A hypothetical person using water at the outlet of the blowdown line at the RFO limits would receive a whole body dose of 500 mrem/year.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 2) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased liquid effluent release concentrations.
Further information on liquid radioactive releases can be found in Chapter 11 of the FSAR (Ref.
3).
Ref. 4 provides initial estimated isotopic annual releases of liquid effluent.
This RFO provides assurance that the concentration of radioactive materials in bodies of water in UNRESTRICTED AREAS will result in exposures within the limits of Part 20.1302(b)(2)(1) of Ref.
- 1. The concentration limit for dissolved or entrained noble gases is based upon the assumption that Xe-135 is the controlling radioisotope and its concentration in air (submersion) was converted to an equivalent concentration in water using the methods described in Ref.
6.
This RFO is applicable at all times since liquid effluents can be released at any time.
Columbia Generating Station (continued)
Amendment 35. MAR 2002 B 6.2.1.1-1
Liquid Concentration B 6.2.1.1 BASES COMPENSATORY MEASURES SURVEILLANCE REQUIREMENTS The concentration of radionuclides being released can be decreased by decreasing the amount of activity being released or by increasing the dilution.
The amount of radioactivity will decrease with time due to decay.
The recycling of water within the plant prior to release will, therefore, decrease the amount of activity available.
The dilution of the waste can occur within the plant prior to release or during blowdown to the river.
This SR defines the radioactive liquid waste sampling and analysis needed to determine the radionuclide concentrations in the effluent.
This program meets the requirements of General Design Criteria 64 in Appendix A of Ref. 5.
It also uses the guidance provided in References 7 and 8.
Liquid Release Type At Columbia Generating Station batch releases are the only release type.
A batch release is the discharge of liquid wastes of a discrete volume.
Prior to sampling for analyses, each batch shall be isolated, and then thoroughly mixed by a method described in plant procedures to assure representative sampling.
SR 6.2.1.1.1 requires a pre release analyses of each batch release.
SamDle and Analysis Freouencv A sample is required to be taken prior to the release of each batch.
This provides assurance of a representative sample of the radioactivity to be released.
The samples must be analyzed prior to the release of each batch.
This allows for a review of the results of the analysis prior to release.
SR 6.2.1.1.2 requires a post-release analysis of samples composited from the batch releases.
For tritium and gross alpha a composite sample is collected prior to the release of each batch.
A composite sample is one in which the quantity of liquid sampled is proportional to the quantity of liquid waste discharged and in which the method of sampling employed results in a specimen that is representative of the liquids released.
This may be (continued)
Columbia Generating Station B 6.2.1.1-2 Amendment 35, MAR 2002
Liquid Concentration Liquid Concentration B 6.2.1.1 BASES SURVEILLANCE Sample and Analysis Frequency (continued)
REQUIREMENTS accomplished through composites of grab samples obtained prior to discharge after the tanks have been recirculated.
Every 31 days the composite sample made up of all the releases during the prior 31 days must be analyzed.
If no releases are made during the previous 31 day period no analysis is required.
This 31 day composite analysis for tritium and gross alpha is considered adequate to characterize the liquid release during this time period.
For Fe-55, Sr-89, and Sr-90 a composite sample is also required for each batch released.
In this case the composite samples may be collected for 92 days prior to analysis.
If no releases occur during the previous 92 day period no analysis is required.
Sample Lower Limit of Detection The LLD is defined in the definitions section of the ODCM Appendix.
The principle gamma emitters for which the LLD definition applies in this RFO includes the following radionuclides: Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs 134, Cs-137, and Ce-141.
Ce-144 shall also be measured, but with an LLD of 5 x 10.6.
This list does not mean that only these nuclides are to be considered.
Other gamma peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Radioactive Effluent Release Report.
Detailed discussions of the LLD and other detections limits can be found in References 9, 10, and 11.
REFERENCES
- 1.
10 CFR 20.1001
- 20.2402.
- 2.
FSAR Section 15.0.3.
- 3.
FSAR 11.2.3.
- 4.
FSAR Table 11.2-14.
- 5.
10 CFR 50.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.1.1-3
Liquid Concentration B 6.2.1.1 BASES REFERENCES (continued)
- 6.
ICRP Publication 2.
- 7.
Reg.
Guide 1.21.
- 8.
Reg.
Guide 4.15.
- 9.
HASL Procedures Manuals, HASL-300 (revised annually).
- 10.
- Currie, L.A. "Limits for Qualitative Detection and Quantitative Determination
- Application to Radiochemistry" Anal.
Chem. 40, 586-93 (1968).
- 11.
- Hartwell, J.K.,
"Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975).
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.1.1-4
Liquid Dose B 6.2.1.2 B 6.2 RADIOACTIVE EFFLUENTS B 6.2.1 Liquid Effluents B 6.2.1.2 Liquid Dose BASES BACKGROUND APPLICABLE SAFETY ANALYSES REOUIREMENTS FOR OPERABILITY This RFO requires a calculation of the dose resulting from the routine release of liquid radioactive effluents.
It implements the requirements of Sections II.A, III.A, and IV.A of Appendix I of Ref. 1.
It should be noted that these RFO limits apply to a MEMBER OF THE PUBLIC.
The dose calculation models are, therefore, allowed to take into account dilution and other factors which decrease the dose between the point of release and the person's location.
This dose calculation provides assurance that any liquid radioactive releases caused by normal operation and Anticipated Operational Transients are evaluated to determine their impact on a MEMBER OF THE PUBLIC.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 2) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased liquid effluent releases.
The FSAR (Ref.
- 3) and the Columbia Generating Station Environmental Report (Ref.
- 4) calculate estimated annual exposure due to liquid effluent release.
The estimated total body dose of 2.3 mrem per year and the largest calculated single organ dose of 1.6 mrem per year to the bone are well below the guidelines of Appendix I of Ref.
1.
The dose calculation methodology and parameters in the ODCM implement the requirements of Section III.A of Appendix I, Conformance with the guidance of Appendix I must be shown by calculational procedures based on models and data, such that the actual exposure of the MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated.
The equations specified in the ODCM for calculating the dose due to the actual release rates of radioactive materials in liquid effluents are consistent with the methodology provided in Ref. 5 and Ref. 6.
For fresh water sites with drinking water supplies that can be (continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.1.2 1
Liquid Dose B 6.2.1.2 BASES REQUIREMENTS FOR OPERABILITY (continued)
APPLICABILITY COMPENSATORY MEASURES SURVEI LLANCE REQUIREMENTS potentially affected by plant operations, there is reasonable assurance that the operation of the facility will not result in radionuclide concentrations in the finished drinking water that are in excess of the requirements of Ref.
7.
This RFO is applicable when radioactive liquid effluents are released.
During the periods of time when no radioactive liquids are released this RFO is not applicable.
The general note is provided to implement the guidance in Ref. 8.
This NUREG states that as long as the calculated dose does not exceed twice the limits of this RFO no extra analysis is required to demonstrate compliance with RFO 6.2.3.1.
If the dose levels exceed twice those cited in this RFO additional analysis must be performed to determine if additional limitations on plant operation will be necessary tc, ensure compliance with Ref. 9.
The COMPENSATORY MEASURES statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I of Ref.
1 to ensure that the releases of radioactive material in liquid effluents to UNRESTRICTED AREAS will be kept "as low as is reasonabi
-- 1'ievable."
This SR
-or this RFO requires a dose calculation every 31 days t rovide assurance that the radioactive liquid effluents released do not result in a dose above the limits stated.
The dose to the total body is calculated for the quarter and year prior to the date of the calculation.
The dose to each organ is calculated for the quarter and year prior to the date of the calculation.
All calculated doses must be below the limits given in this RFO or the COMPENSATORY MEASURES must be implemented.
When no liquid radioactive releases occur during the time period no new calculation is required since the RFO is not applicable.
(continued)
Columbia Generating Station B 6.2.1.2-2 Amendment 35, MAR 2002
Liquid Dose B 6.2.1.2 BASES REFERENCES
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
9.
10 CFR 50.
FSAR Section 15.0.3.
FSAR 11.2.3.3.
Columbia Generating Station Environmental Report, Operating License Stage, Section 5.2.
40 CFR 141.
40 CFR 190.
Columbia Generating Station Amendment 35. MAR 2002 B 6.2.1.2-3
Liquid Waste Management System B 6.2.1.3 B 6.2 RADIOACTIVE EFFLUENTS B 6.2.1 Liquid Effluents B 6.2.1.3 Liquid Waste Management System BASES BACKGROUND APPLICABLE SAFETY ANALYSES REQUIREMENTS FOR OPERABILITY This RFO requires the Liquid Waste Management System to be OPERABLE at all times.
In addition it requires the Liquid Waste Management System to be in service whenever the projected dose calculated prior to release indicates a value above the limit given in the RFO.
The requirement that the appropriate portions of this system be used, when specified, provides assurance that the release of radioactive materials in liquid effluent will be kept "as low as is reasonably achievable."
This RFO implements the requirements of Part 50.36a, General Design Criterion 60 of Appendix A and the design objective given in Section II.D of Appendix I to Ref. 1.
It also implements the requirements of Technical Specification Section 5.5.4.f.
Further guidance on the implementation of the RFO is provided in Refs. 2, 3, and 4.
This RFO provides assurance that liquid radioactive releases caused by normal operating and Anticipated Operational Transients are treated if they are above the given limits.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 5) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased liquid effluent releases.
The OPERABILITY of the Liquid Radioactive Waste Management System ensures that this system will be available for use whenever liquid effluents require treatment prior to release to the environment.
The term "Liquid Waste Management System" involves all of the installed and available Liquid Radioactive Waste Management System equipment, as well as their controls, power, instrumentation, and services that make the system function.
Equipment that is considered standby or redundant is also included, since their function is to assure OPERABILITY.
The RFO also permits alternate treatment paths using alternate subsystems and equipment to (continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.1.3-1
Liquid Waste Management System B 6.2.1.3 BASES REQUIREMENTS FOR OPERABILITY (continued)
APPLICABILITY COMPENSATORY MEASURES SURVEILLANCE REQUIREMENTS be used in the event that the normal treatment equipment is inoperable.
Further information on the design bases, system description, and process description of the Liquid Waste Management System is given in Ref.
- 6.
This RFO requires the Liquid Waste Management System to be in use when the projected doses due to the liquid effluent released to the UNRESTRICTED AREA would exceed 0.06 mrem to the total body or 0.2 mrem to any organ in a 31 day period.
- Thus, the Liquid Waste Management System is required to be in use well before the limits of RFO 6.2.1.2 are reached as required by Section II.A of Appendix I to Ref.
- 1.
If the system is in use radioactive liquid waste can be released up to the limits of RFO 6.2.1.2.
This RFO is applicable at all times since the Liquid Waste Management System must be OPERABLE at all times.
A Special Report to the NRC is required if the Liquid Waste Management System is not OPERABLE for more than 31 days or if the system was not in use and the calculated dose values were found to be above those given in the RFO.
This allows the NRC to be kept informed of any inoperable or unused equipment needed to reduce the dose and the corrective actions being taken to restore it to OPERABLE status.
SR 6.2.1.3.1 To determine if use of the installed equipment is necessary, the cumulative liquid effluent releases over the ensuing 31 days must be projected.
These releases should include all plant effluents from all Liquid Radioactive Waste Management and Liquid Waste Disposal System components that are planned to be operated.
These releases should include a margin, based on operating data, for anticipated and unplanned operational occurrences.
The ODCM methodology used to project the dose shall be the same as that used for SR 6.2.1.2.1.
The impact of this projected cumulative release is to be compared to 0.06 mrem for the total body and 0.2 (continued)
Columbia Generating Station B 6.2.1.3-2 Amendment 35, MAR 2002
Liquid Waste Management System B 6.2.1.3 BASES SURVEILLANCE REQUIREMENTS SR 6.2.1.3.1 (continued) mrem for any organ.
If the projection indicates these values will be exceeded, then the installed Liquid Waste Management System components that will reduce these radioactive materials in the liquid effluent and their projected dose impact must be used.
SR 6.2.1.3.2 The Liquid Waste Management System is considered OPERABLE if the requirements of RFO 6.2.1.1, Liquid Concentration and RFO 6.2.1.2, Liquid Dose are met.
RFO 6.2.1.1 limits the concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS.
These low concentration limits are an indicator of a properly functioning Liquid Waste Management System.
In a similiar manner, RFO 6.2.1.2 limits the dose from liquid effluents.
A low dose from liquid effluents is an indication of an OPERABLE Liquid Waste Management System.
REFERENCES
- 1.
10 CFR 50.
- 2.
NUREG-0473, Revision 2.
- 3.
- 4.
- 5.
FSAR Section 15.0.3.
- 6.
FSAR Section 11.2.
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.1.3 3
Dose Rate B 6.2.2.1 B 6.2 RADIOACTIVE EFFLUENTS B 6.2.2 Gaseous Effluents B 6.2.2.1 Dose Rate BASES BACKGROUND APPLICABLE SAFETY ANALYSES This ODCM Requirement for OPERABILITY (RFO) is provided to ensure the dose rate at any time at and beyond the SITE BOUNDARY from gaseous effluents will be within the annual dose limits of Ref.
- 1. The annual dose limits are the dose rates associated with the concentrations of Appendix B, Table II, Column 1 of Ref.
- 1. These limits provide reasonable assurance that radioactive material discharged in gaseous effluents will not result in the exposures at or beyond the SITE BOUNDARY, that exceed the limits specified.
For MEMBERS OF THE PUBLIC who may at times be within the SITE BOUNDARY, the occupancy of that MEMBER OF THE PUBLIC will be sufficiently low to compensate for any increase in the atmo:1)cric diffusion factor above that for the SITE BOUNDARY.
Examples of calculations for such MEMBERS OF THE PUBLIC, with the appropriate occupancy factors, are provided in the ODCM.
The specified release rate limits restrict, at all times, the corresponding gamma and beta dose rates above background at or beyond the SITE BOUNDARY to less than or equal to 500 mrems/year to the total body or to less than or equal to ?"'i mrems/year to the skin.
These release rate limits al.ý cstrict, at all times the corresponding thyroid dose rate above background to a child via the inhalation pathway to iss than or equal to 1500 mrems/year.
The gaseous effluent dose rate limits provide assurance that any gaseous effluent releases caused by normal operation and Anticipated Operational Transients result in very low exposures to the general public.
A hypothetical person living at or beyond the SITE BOUNDARY would receive a whole body dose of <= 500 mrem/year. Chapter 15, Accident Analysis, of the FSAR (Ref.
- 2) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased gaseous effluent dose rates.
Further information on gaseous radioactive releases can be found in Chapter 11 of the FSAR (Ref.
3).
Estimated gaseous releases from the plant are given in Ref. 4.
(continued)
Columbia Generating Station B 6.2.2.1-1 Amendment 35, MAR 2002
Dose Rate B 6.2.2.1 BASES REQUIREMENTS This RFO provides the dose rate limits for FOR OPERABILITY gaseous radioactive materials released from the plant.
APPLICABILITY This RFO is applicable at all times since gaseous effluents can be released at any time.
COMPENSATORY The dose rate resulting from the release of gaseous MEASURES radionuclides can be decreased by decreasing the amount of radioactivity being released.
The amount of radioactivity will decrease with time due to decay.
The use of the charcoal beds greatly decreases the Iodine and Particulates released and will delay the release of Noble Gases.
This will decrease the amount of activity available for release.
Other actions that would result in a decreased source of radioactivity should be considered. The Reactor Building Sump Vent Exhaust Filter System can be used to decrease the amount of radioactivity released.
SURVEILLANCE These surveillance requirements define the radioactive REQUIREMENTS gaseous waste sampling and analysis needed to determine the radionuclide concentrations and dose rates in the effluent.
This program meets the requirements of General Design Criteria 64 in Appendix A of Ref. 5.
It also conforms to the Refs.
6 and 7.
Table 6.2.2.1-1 defines the radioactive gaseous waste sampling and analysis program.
The table is divided into four sections: 1) those sampling and analysis requirements that are required to be in place at the plant at all times,
- 2) those requirements applicable during purge and vent operations, 3) additional sampling and analysis required during startup and shutdown, and 4) additional requirements that must be followed during significant reactor power changes.
Radioactive Gaseous Samplinq and Analysis Required at All Times (Table 6.2.2.1-1, Part 1)
A primary containment grab sample for Tritium is required to be taken and analyzed every 31 days.
This analysis provides information on any releases that might be occurring within the primary containment structure.
The 31 day sampling (continued)
Columbia Generating Station B 6.2.2.1-2 Amendment 35, MAR 2002
Dose Rate Dose Rate B 6.2.2.1 BASES SURVEILLANCE period is sufficient to identify trends during power REQUIREMENTS operation.
Footnote (a) recognizes the plant configuration (continued) when the primary containment is open and the reactor building becomes the primary confinement space.
In this case the grab sampling being done at the Reactor Building Elevated discharge is representative of all space inside the Reactor Building including primary containment.
A reactor building elevated discharge grab sample for tritium is required every 7 days.
This analysis determines the tritium release in the ventilation exhaust from the spent fuel pool area.
It is required whenever spent fuel is in the fuel pool.
A reactor building elevated discharge noble gas grab sample and analysis for gamma emitters is required every 31 days.
The principal gamma emitters for noble gas effluents are defined under the LLD discussion in this bases.
This analysis identifies the gamma emitters in the gaseous effluent stream that are needed to perform the dose rate calculations.
A 31 day sampling and analysis period is sufficient to characterize this release.
Turbine and radwaste building vent noble gas and tritium grab samples and analysis for principal gamma emitters and tritium are required every 31 days.
The principal gamma emitters for noble gas effluents are defined under the LLD discussion in this bases.
This analysis identifies the gamma emitters and tritium in the gaseous effluent stream that is needed to perform the dose rate calculations.
The tritium analysis provides information on the trend of steam leaks in these two areas.
A 31 day analysis period is sufficient to characterize this release.
Continuous charcoal filter samples are collected from all three building vent gaseous effluent streams.
Every seven days the charcoal filters are to be removed and analyzed.
This analysis provides information on the halogen (iodine) isotopes being released from the plant and is used to calculate the halogen dose rate due to gaseous effluents.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.2.1-3
Dose Rate B 6.2.2.1 BASES SURVEILLANCE Continuous particulate filter samples are collected from all REQUIREMENTS three building vent gaseous effluent streams.
Every seven (continued) days these particulate filters are removed and analyzed.
This analysis provides information on the gamma emitters collected in the sample.
A composite of the continuous particulate filter sample is collected from all building vents.
Every 31 days these samples are totalized for gross alpha.
Every 92 days these composite samples are analyzed for strontium. These analyses provide information on possible trends in fuel performance.
The noble gas monitor provides a continuous record of noble gas release from the plant.
The gross gamma and beta count rates along with the periodic grab samples are used to characterize the noble gas release and calculate the dose rate.
Footnote (b) notes the importance of the ratio of sample flow rate to the sampled effluent stream flow.
This provides one of several values needed for estimating the dose rate.
Radioactive Gaseous Sampling and Analysis Required During PURGE or VENT (Table 6.2.2.1-1, Part 2)
Primary Containment grab sampling and analysis is not required if a VENT release (by the two inch exhaust lines) is through the Standby Gas Treatment System and the noble gas monitors in containment are reading below their setpoint as stated in footnote (d).
Under these conditions, grab sampling is not required as the gaseous effluent will be released at a slow rate, will be filtered, and will be measured by the Reactor Building Elevated Discharge noble gas, iodine, and particulate monitors.
Additional requirements on VENTING and PURGING are found in RFO 6.2.2.6.
During other PURGE or VENT conditions, primary containment noble gas, iodine, and particulate grab samples are required prior to each PURGE or VENT.
The sample must be taken no more than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> before the PURGE or VENT.
The sample must be analyzed for gamma emitters prior to the PURGE or VENT.
This analysis determines the status of radioactivity in the primary containment atmosphere prior to the release.
(continued)
Columbia Generating Station B 6.2.2.1 4 Amendment 35, MAR 2002
Dose Rate B 6.2.2.1 BASES SURVEILLANCE REQUIREMENTS (continued)
If the Reactor Building Elevated Discharge Low Range Radiation Monitor is not OPERABLE, sampling and analysis of the containment shall be completed at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> during PURGE AND VENT.
With an inoperable Reactor Building Elevated Discharge Low Range Radiation Monitor this additional sampling provides additional data to characterize the release from containment.
This additional sampling is required for a VENT release through the Standby Gas Treatment System even when the noble gas monitors in containment are reading below their setpoint if the VENT exceeds 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
Radioactive Gaseous Sampling and Analysis Required During Startup and Shutdown (Table 6.2.2.1-1, Part 3)
Noble gas, iodine, and particulate grab samples are required from the Primary Containment and the Reactor Building following startup and shutdown. These grab samples are analyzed for gamma emitters to provide information about any changes in gaseous activity during large power changes.
Grab samples in the reactor building vent are normally taken during startup following the start of the Steam Jet Air Ejectors and shutdown of the Mechanical Vacuum Pump.
During shutdown, reactor building vent samples are taken after the Steam Jet Air Ejector is turned off and transition is made to the Mechanical Vacuum Pump. Taking grab samples at this time allows a better definition of the radioactivity being released during this transition.
Additional steps must be taken during Startup and Shutdown to determine if additional sampling is required. The first step is taken between 2 to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> after the beginning of a startup or shutdown.
At this point, the DOSE EQUIVALENT 1-131 concentration in the primary coolant is evaluated.
If it is less than 1.OE-03 yCi/cc or if it is above 1.OE-03 pCi/cc but has not changed more than a factor of three, additional sampling is not required because of high iodine concentration in the primary coolant.
The low concentration or lack of change of concentration in the primary coolant is an indication of stable fuel performance that does not require additional effluent sampling.
The second step to determine if additional sampling is required involves the building vent Noble Gas Monitors.
If all of the building vent monitors are less than or equal (continued)
Columbia Generating Station Amendment 35, MAR 2002 8 6.2.2.1-5
Dose Rate Dose Rate B 6.2.2.1 BASES SURVEILLANCE to two percent of their setpoint or if they are greater than REQUIREMENTS two percent of the setpoint but have not increased more than (continued) a factor of three then additional tests are not required.
A high and changing noble gas radioactivity reading from the building monitors during startup or shutdown operation could be an indication of an unusual condition within that building and additional sampling is required.
If the high and changing primary coolant radioactivity or high and changing building vent activity triggers additional testing, filters shall be removed from the continuous sampler at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
This additional sampling must take place for at least seven days following shutdown or startup.
The analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of filter removal.
When samples collected for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> are analyzed, the corresponding LLDs may be increased by a factor of 10.
Once this condition is entered it must be followed to completion for the seven day time period even if the primary coolant or building vent radioactivity levels decrease below the trigger point.
Footnote (b) notes the importance of the ratio of sample flow rate to the sampled effluent stream flow.
This provides one of several values needed for estimating the dose rate.
Radioactive Gaseous Sampling and Analysis Required During Reactor Power Changes (Table 6.2.2.1-1, Part 4)
Following THERMAL POWER changes exceeding 15% of RATED THERMAL POWER within a 1-hour period a determination must be made to see if radioactive grab sampling is required from the Containment and Reactor Building Elevated Discharge.
If the main condenser offgas pre-treatment monitor is indicating less than or equal to 15,000 pCi/sec, no sampling is required.
To convert the pretreatment monitor reading from mr/hr to yCi/sec multiply the average monitor reading from OG-RR-604 in mr/hr by the Offgas System flow rate from OG-FR-620 in cfm. A low pre-treatment monitor reading is an indication of stable fuel performance during Reactor Power Changes that does not require sampling.
If the main (continued)
Columbia Generating Station B 6.2.2.1-6 Amendment 35, MAR 2002
Dose Rate Dose Rate B 6.2.2.1 BASES SURVEILLANCE condenser offgas pre-treatment monitor is greater than REQUIREMENTS 15,000 pCi/sec, Noble Gas, Iodine, and Particulate Grab (continued) samples are required from the Primary Containment and the the Reactor Building.
Additional steps must also be taken during Reactor Power changes to determine if additional continuous filter sampling is required. Between 2 to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> after the beginning of a reactor power change, with the off-gas pre treatment monitor greater than 15,000 pCi/sec, the DOSE EQUIVALENT 1-131 concentration in the primary coolant is evaluated.
If it is less than the 1.OE-03 vCi/cc or if it is above 1.OE-03 jCi/cc but has not changed more than a factor of three additional sampling is not required because of high iodine concentration in the primary coolant.
The low concentration or lack of change of concentration in the primary coolant is an indication of stable fuel performance that does not require additional effluent sampling.
The second step to determine if additional continuous filter sampling is required involves the building vent Noble Gas Monitors.
If all of the building vent monitors are less than or equal to two percent of their setpoint or if they are greater than two percent of the setpoint but have not increased more than a factor of three, then additional tests are not required.
A high and changing noble gas radioactivitv reading from the building monitors during startup :
hutdown operation could be an indication of an unusual condition within that building and additional sampling ic required.
If the DOSE EQUIVALENT 1-131 concentrc,,un and the building vent monitors meet the criteria above, no additional continuous filter sampling is required even if the main condenser off-gas pre-treatment monitor reading is greater than 15,000 pCi/sec.
- However, a high and changing primary coolant radioactivity or high and changing building vent activity requires additional continuous filter testing.
Filters shall be removed from the continuous samplers in all building vents at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
This additional sampling must take place for at least seven days following THERMAL POWER changes as defined above.
The analyses shall be completed (continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.2.1-7
Dose Rate B 6.2.2.1 BASES SURVEILLANCE REOUIREMENTS (continued) within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of filter removal.
When samples collected for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> are analyzed, the corresponding LLDs may be increased by a factor of 10. Once this condition is entered it must be followed to completion for the seven day time period even if the primary coolant or building vent radioactivity levels decrease below the trigger point.
Footnote (b) flow rate to provides one dose rate.
notes the importance of the ratio of sample the sampled effluent stream flow.
This of several parameters needed for estimating the Sample Lower Limit of Detection The LLD is defined in the definitions section of the ODCM.
The principal gamma emitters for which the LLD specification applies in this RFO includes the following radionuclides:
Kr-87, Kr-88, Xe-133, Xe-133m, Xe-135, and Xe-138 in noble gas releases and Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, 1-131, Cs-134, Cs-137, Ce-141, and Ce-144 in iodine and particulate releases.
Other gamma peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Radioactive Effluent Release Report.
Detailed discussion of the LLD and other can be found in References 8, 9 and 10.
REFERENCES detections limits
- 1.
10 CFR 20.1-20.602.
- 2.
FSAR Section 15.0.3.
- 3.
FSAR Section 11.3.3.
- 4.
FSAR Section 11.3.3.3.
- 5.
10 CFR 50.
- 6.
- 7.
(continued)
Columbia Generating Station B 6.2.2.1-8 Amendment 35, MAR 2002
Dose Rate B 6.2.2.1 BASES REFERENCES
- 8.
HASL Procedures Manuals, HASL-300 (revised annually).
(continued)
- 9.
Currie, L.A.,
"Limits for Qualitative Detection and Quantitative Determination
- Application to Radiochemistry" Anal.
Chem. 40, 586-93 (1968).
- 10.
- Hartwell, J.K., "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975).
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.2.1-9
Dose
- Noble Gases B 6.2.2.2 B 6.2 RADIOACTIVE EFFLUENTS B 6.2.2 Gaseous Effluents B 6.2.2.2 Dose - Noble Gases BASES BACKGROUND This ODCM Requirement for OPERABILITY (RFO) requires a calculation of the noble gas air dose resulting from gaseous effluent release.
It implements the requirements of Sections II.B, III.A, and IV.A of Appendix I, of Ref. 1.
It also implements Technical Specification Sections 5.5.4.e and 5.5.4.h.
These RFO limits apply at any location at or beyond the site boundary.
APPLICABLE This air dose calculation provides assurance that any SAFETY ANALYSES gaseous noble gas radioactive releases caused by normal operation and Anticipated Operational Transients are evaluated to determine their impact on a MEMBER OF THE PUBLIC.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 2) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased gaseous effluent releases. The FSAR (Ref.
- 3) lists a number of events that result in steam being discharged to the suppression pool.
The non-condensible noble gases present in this steam will migrate from the primary containment to the Reactor Building and be released through the Reactor Building Elevated Release vent. The Columbia Generation Station Environmental Report (Ref.
- 4) calculates the estimated annual exposure due to gaseous effluent release.
REQUIREMENTS The dose calculation methodology and parameters in the ODCM FOR OPERABILITY implement the requirements of Section III.A of Appendix I of Ref.
- 1. Conformance with the guidance of Appendix I must be shown by calculational procedures based on models and data, such that the actual exposure at locations at or beyond the SITE BOUNDARY is unlikely to be substantially underestimated.
The equations specified in the ODCM for calculating the doses due to the actual release rates of noble gases in gaseous effluents are consistent with the methodology provided in Refs.
5 and 6.
(continued)
Columbia Generating Station B 6.2.2.2-1 Amendment 35, MAR 2002
Dose - Noble Gases B 6.2.2.2 BASES APPLICABILITY COMPENSATORY MEASURES This RFO is applicable at all times since gaseous effluents can be released at any time.
The general note is provided to implement the guidance in Ref.
- 7.
This NUREG states that as long as a nuclear plant operates at a level below twice the reporting requirement of this RFO no extra analysis is required to demonstrate compliance with RFO 6.2.3.1.
If the dose levels cited in this RFO are exceeded by a factor of two, additional analysis must be performed to determine if additional limitations on plant operation will be necessary to ensure compliance with Ref.
8.
The COMPENSATORY MEASURES statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I of Ref. 1 to assure that the releases of radioactive material in gaseous effluents to UNRESTRICTED AREAS will be kept "as low as is reasonably achievable."
SURVEILLANCE The surveillance requirement for this RFO requires a dose REQUIREMENTS calculation every 31 days to provide assurance that the air dose due to noble gases does not result in a dose above the limits stated.
The dose is calculated for the quarter and year based on actual and projected effluents for the 31 day period being analyzed.
All calculated doses must be below the limits given in this RFO or the COMPENSATORY MEASURES must be implemented.
REFERENCES
- 1.
10 CFR 50.
- 2.
FSAR Section 15.0.3.
- 3.
FSAR Table 11.3-10 Section 11.3.3.3.
- 4.
Columbia Generating Station Environmental Report, Operating License Stage, Table 5.2-14.
(continued)
Columbia Generating Station B 6.2.2.2-2 Amendment 35, MAR 2002
Dose - Noble Gases B 6.2.2.2 BASES REFERENCES
- 5.
(continued)
- 6.
- 7.
- 8.
40 CFR 190.
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.2.2-3
Dose 131, 1-133, Tritium, and Radionuclides in Particulate Form B 6.2.2.3 B 6.2 RADIOACTIVE EFFLUENTS B 6.2.2 Gaseous Effluents B 6.2.2.3 Dose 131, 1-133, Tritium, and Radionuclides in Particulate Form BASES BACKGROUND APPLICABLE SAFETY ANALYSES REQUIREMENTS FOR OPERABILITY This ODCM Requirement for OPERABILITY (RFO) requires a calculation of the dose resulting from gaseous effluent release containing 1-131, 1-133, Tritium, and Radionuclides in Particulate Form (I-T-P).
It implements the requirements of Sections II.C, III.A, and IV.A of Appendix I, of Ref. 1.
It also implements Technical Specification Sections 5.5.4.e and 5.5.4.i.
These RFO limits apply to a MEMBER OF THE PUBLIC.
The dose calculation models are, therefore, allowed to take into account the additional diffusion and other source depletion between the point of release and locations occupied by individuals in the UNRESTRICTED AREA.
This organ dose calculation provides assurance that any I-T-P radioactive releases caused by normal operation and Anticipated Operational Transients are evaluated to determine their impact on a MEMBER OF THE PUBLIC.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 2) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased I-T-P gaseous effluent releases. The Columbia Generating Station Environmental Report (Ref.
- 3) calculates the estimated annual exposure due to gaseous effluent release.
Gaseous Waste Management System radioactive releases are discussed in Ref. 4.
The dose calculation methodology and parameters in the ODCM implement the requirements of Section III.A of Appendix I of Ref.
- 1. Conformance with the guidance of Appendix I must be shown by calculational procedures based on models and data, such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated.
The equations specified in the ODCM for calculating the doses due to the actual release rates of I-T-P in gaseous effluents are consistent with the methodology provided in Refs.
5 and 6.
The release rate (continued)
Columbia Generating Station B 6.2.2.3-1 Amendment 35, MAR 2002
Dose 131, 1-133, Tritium, and Radionuclides in Particulate Form B 6.2.2.3 BASES REQUIREMENTS FOR OPERABILITY (continued)
APPLICABILITY COMPENSATORY MEASURES specifications for I-T-P are dependent upon the existing radionuclide pathways to man in UNRESTRICTED AREAS.
The pathways that were examined in the development of these calculations were:
(1) individual inhalation of airborne radionuclides, (2) deposition of radionuclides onto green leafy vegetation with subsequent consumption by man, (3) deposition onto grassy areas where milk animals and meat-producing animals graze with consumption of the milk and meat by man, and (4) deposition on the ground with subsequent exposure of man.
This RFO is applicable at all times since I-T-P effluents can be released at any time.
The general note is provided to implement the guidance in Ref.
- 7.
This NUREG states that as long as a nuclear plant operates at a level below twice the reporting requirement of this RFO no extra analysis is required to demonstrate compliance with RFO 6.2.3.1.
If the dose levels cited in this RFO are exceeded by a factor of two, additional analysis must be performed to determine if additional limitations on plant operation will be necessary to ensure compliance with Ref.
8.
The COMPENSATORY MEASURES statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I of Ref 1 to assure that the releases of I-T-P radioactive material in gaseous effluents to UNRESTRICTED AREAS will be kept "as low as is reasonably achievable."
SURVEILLANCE REQUIREMENT The surveillance requirement for this RFO requires a dose calculation every 31 days to provide assurance that the organ dose due to I-T-P does not result in a dose above the limits stated.
The dose is calculated for the quarter and year based on actual and projected effluents for the 31 day period being analyzed.
All calculated doses must be below the limits given in this RFO or the COMPENSATORY MEASURES must be implemented.
(continued)
Columbia Generating Station B 6.2.2.3-^
Amendment 35, MAR 2002
Dose -
1-131. 1-133. Tritium, and Radionuclides in Particulate Form Dose 131, 1-133, Tritium. and Radionuclides in Particulate Form B 6.2.2.3 BASES (continued)
REFERENCES
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
8.
10 CFR 50.
FSAR Section 15.0.3.
Columbia Generating Station Environmental Report, Operating License Stage, Table 5.2-14.
FSAR Section 11.3.3.
40 CFR 190.
Columbia Generating Station Amendment 35. MAR 2002 B 6.2.2.3-3
GASEOUS OFFGAS TREATMENT SYSTEM B 6.2.2.4 B 6.2 RADIOACTIVE EFFLUENTS B 6.2.2 Gaseous Effluents B 6.2.2.4 GASEOUS OFFGAS TREATMENT SYSTEM BASES BACKGROUND APPLICABLE SAFETY ANALYSES This ODCM Requirement for OPERABILITY (RFO) requires the GASEOUS OFFGAS TREATMENT SYSTEM be available for use in either the normal or charcoal bypass mode of operation.
The requirement that the appropriate portions of these systems be used, when specified, provides reasonable assurance that the releases of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable."
This Requirement for OPERABILITY implements the requirements of 10 CFR 50.36a, General Design Criterion 60 of Appendix A of Ref.
- 1.
It also implements the design objectives given in Section II.D of Appendix I of Ref 1 and Technical Specification Section 5.5.4.f.
Further guidance on the implemenT-it-on of this RFO is provided in Refs.
2, 3 and 4.
A GASEOUS OFFGAS TREATMENT SYSTEM is defined as any system designed and installed to reduce radioactive gaseous effluents by collecting primary coolant system offgases from the primary system and providing for delay or holdup for the purpose of reducing the total radioactivity prior to release to the en 'i-onment.
This RFO p, vides assurance that gaseous radioactive releases
- -m the main condenser when the steam jet air ejectors are in service are monitored or processed.
These radioactive releases occur as a result of normal operation or could be caused by Anticipated Operational Transients.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 5) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased gaseous effluent releases.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.2.4-1
GASEOUS OFFGAS TREATMENT SYSTEM B 6.2.2.4 BASES REQUIREMENTS FOR OPERABILITY APPLICABILITY COMPENSATORY MEASURES The OPERABILITY of the GASEOUS OFFGAS TREATMENT SYSTEM ensures that this system will be available for use whenever these gaseous effluents require treatment prior to release to the environment.
The term "gaseous offgas treatment system" involves all of the installed and available gaseous radioactive waste management system equipment, as well as their controls, power, instrumentation, and services that make the system functional.
Equipment that is considered standby or redundant is also included, since their function is to assure OPERABILITY.
The RFO also permits alternate treatment paths using alternate subsystems and equipment to be used in the event that the normal treatment equipment is inoperable.
In the bypass mode of operation the offgas post-treatment monitors must be operational and capable of automatically changing to normal mode of operation if their setpoint is exceeded.
Further information on the design bases, system description, and process description of the Gaseous Waste Management System is given in Ref. 6.
This RFO is applicable when the main condenser steam jet air ejector (evacuation) system is in operation.
During plant startup, prior to the use of the steam jet air ejector, the mechanical vacuum pump is used to remove air from the condenser.
The normal mode of operation of the GASEOUS OFFGAS TREATMENT SYSTEM is with the charcoal beds in operation.
This provides for the removal of most iodine and particulate radioactive isotopes and delays the release of noble gases.
If the system is not being operated in the normal mode compensatory measure A.1 requires it to be placed in the normal mode in 7 days.
If the required compensatory measure A.1 and the associated 7 day completion time is not met a Special Report must be submitted to the NRC that identifies the required inoperable equipment and the reasons for the inoperability, corrective actions taken to restore the required inoperable equipment to OPERABLE status, and the corrective actions to prevent recurrence.
(continued)
Columbia Generating Station B 6.2.2.4-2 Amendment 35, MAR 2002
GASEOUS OFFGAS TREATMENT SYSTEM B 6.2.2.4 BASES COMPENSATORY The NRC requires the report once the GASEOUS OFFGAS MEASURES TREATMENT SYSTEM is not in the normal mode of operation for (continued) more than 7 days.
The report must be completed 30 days after condition B is entered.
SURVEILLANCE SR 6.2.2.4.1 REQUIREMENTS This surveillance provides verification of GASEOUS OFFGAS TREATMENT SYSTEM operation in either the normal mode or the bypass mode provided the offgas post-treatment radiation monitor is OPERABLE every 7 days.
The main purpose of this surveillance is to provide assurance that the system is being operated in the normal mode with the charcoal beds in service.
REFERENCES
- 1.
10 CFR 50.
- 2.
NUREG-0473, Rev.
- 2.
- 3.
- 4.
- 5.
FSAR Section 15.0.3.
- 6.
FSAR Section 11.3.
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.2.4-3
Reactor Building Sump Vent Exhaust Filter System B 6.2.2.5 B 6.2 RADIOACTIVE EFFLUENTS B 6.2.2 Gaseous Effluents B 6.2.2.5 Reactor Building Sump Vent Exhaust Filter System BASES BACKGROUND This ODCM Requirement for OPERABILITY (RFO) is required for the "Ventilation Exhaust Treatment Systems" in the Standard Radiological Effluent Technical Specifications for BWRs (Refs.
1 and 2).
The only VENTILATION EXHAUST TREATMENT SYSTEM at Columbia Generating Station is the Reactor Building Sump Vent Exhaust Filter System.
This system collects effluent from the building sumps and processes it through a filter system.
In the Reactor Building all potentially radioactive leaks and/or spills are channeled to the equipment and floor drain system.
To minimize the release of radioactive contaminants from the building, the drain system sumps and drain headers are maintained at a negative pressure and vented through this filter system.
The Reactor Building Sump Vent Exhaust Filter System is composed of two, full-capacity, filter units that draw air from the sumps and drain headers and pass it through filters, a moisture separator, and electric heater before discharge to the main reactor building exhaust system.
Further information on this system can be found in Ref.
- 3.
The OPERABILITY of the Reactor Building Sump Vent Exhaust Filter System ensures that the system will be available for use whenever gaseous effluents require treatment prior to release to the environment.
The requirement that the appropriate portions of this system be used, when specified, provides assurance that the releases of radioactive materials in gaseous effluent will be kept "as low as is reasonably achievable."
This RFO implements the requirements of Part 50.36a, General Design Criterion 60 of Appendix A and the design objective given in Section II.D of Appendix I of Ref. 4.
The specified limits governing the use of appropriate portions of the system were specified as a suitable fraction of the dose design objectives set forth in Sections II.B and II.C of Appendix I of Ref.
4 for gaseous effluents.
Columbia Generating Station (continued)
Amendment 35. MAR 2002 B 6.2.2.5-1
Reactor Building Sump Vent Exhaust Filter System B 6.2.2.5 BASES APPLICABLE SAFETY ANALYSES REQUIREMENTS FOR OPERABILITY APPLICABILITY This RFO provides assurance that gaseous radioactive releases caused by normal operation and Anticipated Operational Transients associated with the Reactor Building sumps are treated.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 5) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased gaseous effluent releases.
This RFO has two parts.
The first requirement is for the system to be operable and the second is for the system to be used.
The Reactor Building Sump Vent Exhaust Filter System involves all of the installed and available system equipment, as well as their controls, power, instrumentation, and services that make the system functional.
Equipment that is considered standby or redundant is also included, since their function is to assure OPERABILITY.
The Reactor Building Sump Vent Exhaust Filter System is to be used whenever the projected gaseous effluent 31 day organ dose is above 0.3 mrem.
This dose is calculated for all gaseous releases from all buildings.
The 0.3 mrem organ dose specified in this RFO is a fraction of the quarterly limit of RFO 6.2.2.3.
The Reactor Building Sump Vent Exhaust Filter System must be used when the projected organ dose reaches the 0.3 mrem limit.
This RFO is applicable at all times as the Reactor Building Sump Vent Exhaust Filter System may be required at any time.
COMPENSATORY If the Reactor Building Sump Vent Exhaust Filter System is MEASURES not OPERABLE for more than 31 days at any time a Special Report must be written to the NRC.
This allows the NRC to be kept informed of any inoperable equipment needed to reduce the dose and the corrective actions being taken to restore it to OPERABLE status.
(continued)
Columbia Generating Station B 6.2.2.5-2 Amendment 35, MAR 2002
Reactor Building Sump Vent Exhaust Filter System B 6.2.2.5 BASES COMPENSATORY If the Reactor Building Sump Vent Exhaust Filter System is MEASURES not in service when the projected 31 day organ dose is (continued) above 0.3 mrem a Special Report must be written to the NRC in the next 30 days.
This 31 day organ dose calculation is required by SR 6.2.2.5.1.
SURVEILLANCE SR 6.2.2.5.1 REQUIREMENTS This surveillance requires a projection of the 31 day organ dose every 31 days.
This dose calculation is used to determine if the Reactor Building Sump Vent Exhaust Filter System must be used during that time period.
SR 6.2.2.5.2 The Reactor Building Sump Vent Exhaust Filter System must be demonstrated to be OPERABLE every 92 days by operating the system for at least 10 minutes.
This surveillance is not required if the system has been utilized to process radioactive gaseous effluents during the previous 92 days.
REFERENCES
- 1.
NUREG-0473, Rev.
- 2.
- 2.
- 3.
FSAz. ction 9.4.2.2.3.
- 4.
10 rcR 50.
- 5.
FSAR Section 15.0.3.
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.2.5-3
VENTING or PURGING B 6.2.2.6 B 6.2 RADIOACTIVE EFFLUENTS B 6.2.2 Gaseous Effluents B 6.2.2.6 VENTING or PURGING BASES BACKGROUND This ODCM Requirement for OPERABILITY (RFO) provides assurance that releases from primary containment during VENTING or PURGING operations will be as low as reasonably achievable.
This RFO implements the requirement of Appendix I to Ref.
1 and Technical Specification Section 5.5.4.k.
A description of the PURGE and VENT System is provided in Ref.
- 2.
Sampling requirements during PURGE and VENT operation are given in RFO 6.2.2.1. Gaseous Effluents-Dose Rate.
APPLICABLE This RFO provides assurance that gaseous radioactive SAFETY ANALYSES releases from the containment caused by normal operation and Anticipated Operational Transients are filtered during the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of release.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 3) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased gaseous effluent releases to containment.
REQUIREMENTS This RFO provides three different conditions that must be FOR OPERABILITY considered during VENTING and PURGING.
The first two state the requirements that must be met during the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of VENTING and PURGING operation when the Standby Gas Treatment (SGT) must be used to filter the releases from the Primary Containment.
The SGT train(s) being used for filtration must be "functional for filtration."
SGT functionality as used in this RFO shall include the ability to accept the exhaust gases from primary containment, process the gases through the filtration unit, and discharge the gases to either the reactor building stack or the reactor building.
In Modes 1, 2, or 3, the SGT train not being used for filtration is required to be OPERABLE.
The requirement to have the second train OPERABLE addresses the fact that when the 24-inch or 30-inch exhaust valves are used the (continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.2.6-1
VENTING or PURGING B 6.2.2.6 BASES REQUIREMENTS FOR OPERABILITY (continued) in-service standby gas treatment system train used for filtration of the exhaust gases is inoperable. This is due to the potential for post-LOCA over-pressurization of that train.
The over-pressurization could be caused by the postulated rapid pressurization of containment during LOCA conditions before the qualified containment isolation valves close.
This condition does not exist if the 2-inch valves are being used as the SGT and the valve closure are designed to maintain SGT integrity in response to post-LOCA pressurization.
There are also control considerations that impact SGT operability.
The train being used for filtration requires its SGT controller to be placed in the manual mode which makes that train inoperable since it cannot automatically perform its safety related function if required.
The use of manual control is required to initiate all VENTING and PURGING configurations including the use of the 2 inch lines. The assurance of an OPERABLE second SGT train avoids the potential of having the plant enter LCO 3.0.3 as a result of two inoperable SGT trains.
In Mode 4 when VENTING or PURGING for deinerting it is acceptable to have both standby gas treatment system trains in service supporting filtration for the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of any VENTING and PURGING operation.
In Mode 4 there are no postulated accidents that could result in over pressurization of the standby gas treatment system trains.
- However, if manual control is used for both SGT trains resulting in both trains being INOPERABLE Technical Specification LCO 3.6.4.3 is applicable.
It requires no movement of irradiated fuel assemblies in secondary containment, suspension of CORE ALTERATIONS, and suspension of OPDRVs.
Following the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of any VENTING and PURGING operation filtration through SGT is no longer required.
potential for contamination of the primary containment atmosphere is highest during this initial time period.
The APPLICABILITY This RFO is applicable in MODES 1, 2, and 3 when VENTING and PURGING.
It is also applicable when deinerting the containment.
This RFO is not APPLICABLE during primary (continued)
Columbia Generating Station B 6.2.2.6-21 Amendment 35. MAR 2002
VENTING or PURGING B 6.2.2.6 w
BASES APPLICABILITY containment depressurization following Type A testing (continued) required by Ref. 4.
However, during primary containment depressurization following Type A testing appropriate radioactive sampling shall be performed.
COMPENSATORY If RFO 6.2.2.6 is not met VENTING and PURGING of the MEASURES containment must be discontinued immediately.
SURVEILLANCE SR 6.2.2.6.1 REQUIREMENTS This surveillance requires verification that the containment VENT and PURGE system is aligned in the correct manner.
This verification is required no more than 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> before the start of VENT and PURGE operations and every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> thereafter.
This provides assurance that equipment will function in the manner intended.
REFERENCES
- 1.
10 CFR 50.
- 2.
FSAR Section 6.2.1.1.8.2.
- 3.
FSAR Section 15.0.3.
- 4.
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.2.6-3
Total Dose B 6.2.3 B 6.2 RADIOACTIVE EFFLUENTS B 6.2.3 Total Dose BASES BACKGROUND This RFO is provided to ensure conformance to the U. S. Environmental Protection Agency (EPA) radiation protection standard contained in Ref.
- 1. In Ref.
2 the NRC issued guidance on how the EPA standard is to be implemented and interfaced with its own regulations.
The NRC guidance states that compliance with the EPA regulations is assured if the calculated dose from liquid and gaseous effluents remains below twice the limits of Ref.
- 3.
This RFO implements this guidance.
APPLICABLE This dose calculation provides assurance that all SAFETY ANALYSES radioactive releases and direct radiation caused by normal operation and Anticipated Operational Transients are evaluated tO determine their impact on a MEMBER OF THE PUBLIC.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 4) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased effluent releases and direct radiation.
The Columbia Generating Station Environmental Report (Ref.
- 5) provides estimated calculated annual doses for Columbia Generatir" "tation.
REQUIREMENTS This RFO reo:jires a calculation of the dose or dose FOR OPERABILITY commitmer'
- rom all uranium fuel cycle sources.
The method of calculation is given in the ODCM and uses the standard methodology required to satisfy the requirements of Ref.
- 6.
The dose is to be calculated for a MEMBER OF THE PUBLIC in the UNRESTRICTED AREA surrounding the plant.
This RFO adds the additional requirement that direct radiation must be added to the total dose.
While the direct radiation from Turbine Building shine can be measurable at distances near the building it is not expected to be significant in the UNRESTRICTED AREA beyond the SITE BOUNDARY.
This calculation must also consider other direct radiation sources such as spent fuel storage facilities. A direct measurement of the direct radiation can be obtained from Environmental Monitoring devices.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.2.3-1
Total Dose B 6.2.3 BASES APPLICABILITY COMPENSATORY MEASURES This RFO is applicable at all times since effluents can be released at any time.
This RFO is related to RFOs 6.2.1.2, (Dose-Liquid Effluent), 6.2.2.2, (Dose-Noble Gases),
and 6.2.2.3, (Dose I-T-P). Condition A is entered when the dose calculated by the surveillance requirements associated with any of these RFOs reaches twice the limit specified.
The compensatory measure requires a calculation of the total dose including the contribution from direct radiation.
The direct radiation calculation shall include the contribution from the plant, outside storage tanks, and any outside fuel storage facilities.
If the calculated total dose exceeds the limits of this RFO compensatory measure B.1 must be implemented.
This requires a Special Report to the NRC within 30 days.
The Special Report shall be submitted pursuant to Appendix I,Section IV.A of Ref. 3.
The Special Report shall define the corrective action to be taken to reduce subsequent releases to prevent recurrence of exceeding the RFO limits including a schedule for achieving conformance with the above limits.
This Special Report must also conform to the requirements of Part 20.2203.A of Ref. 7. The special report shall include an analysis that estimates the radiation exposure (dose) to a MEMBER OF THE PUBLIC from uranium fuel cycle sources including all effluent pathways and direct radiation within a radius of eight km, for the calendar year that includes release(s) covered by the report.
An individual is not considered a MEMBER OF THE PUBLIC during any period in which he/she is engaged in carrying out any operation that is part of the nuclear fuel cycle.
It shall also describe levels of radiation and concentrations of radioactive material involved, and the cause of the exposure levels or concentrations.
If the estimated dose(s) exceeds the limits of this RFO, and if the release condition resulting in violation of Ref.
1 has not already been corrected, the Special Report shall include a request for a variance in accordance with the provision of Ref. 1. Submittal of the report is considered a timely request, and a variance is granted until staff action on the request is complete.
The variance only relates to the limits of Ref. 1, and does not apply in any way to the other requirements for dose limitation of Refs.
3 and 7.
(continued)
Columbia Generating Station B 6.2.3-2 Amendment 35, MAR 2002
Total Dose B 6.2.3 BASES SURVEILLANCE REOUIREMENTS REFERENCES This surveillance requires a determination of the dose or dose commitment to any MEMBER OF THE PUBLIC in the UNRESTRICTED AREA from liquid and gaseous effluents.
This surveillance requirement is related to the surveillance requirements 6.2.1.2.1, (Dose-Liquid Effluent), 6.2.2.2.1, (Dose-Noble Gases),
and 6.2.2.3.1, (Dose-I-T-P).
When the calculated dose in these surveillances reach twice the limit specified it triggers a calculation of the total dose.
- 1.
40 CFR Part 190.
- 2.
- 3.
- 4.
FSAR Section 15.0.3.
- 5.
Columbia Generating Station Environmental Report, Operating License Stage, Table 5.2-14.
- 6.
- 7.
10 CFR Part 20.
Columbia Generating Station B 6.2.3-3 Amendment 35, MAR 2002
Radiological Environmental Monitoring Program B 6.3.1 B 6.3 RADIOLOGICAL ENVIRONMENTAL MONITORING B 6.3.1 Radiological Environmental Monitoring Program BASES BACKGROUND APPLICABLE SAFETY ANALYSES REQUIREMENTS FOR OPERABILITY The Radiological Environmental Monitoring Program (REMP) required by this Requirement for OPERABILITY (RFO) provides representative measurements of radiation and of radioactive materials in the environment near Columbia Generating Station.
It includes all exposure pathways for those radionuclides that lead to the highest potential radiation exposures of members of the public resulting from the plant operation.
This monitoring program implementsSection IV.B.2 of Appendix I to Ref.
1 and thereby supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways.
Guidance for this monitoring program is provided by Ref.
2.
This Radiological Environmental Monitoring Program provides assurance that radiation levels in the environment caused by normal operation and Anticipated Operational Transients are evaluated to determine their impact on a MEMBER OF THE PUBLIC.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 3) analyzes a number of anticipated process disturbances and component failures that have the potential of causing increased environmental impact.
This RFO, through Table 6.3.1-1, specifies sample locations,
- analyses, and frequencies for several different exposure pathways.
The RFO is a comprehensive radiological environmental surveillance program to assess the impact of plant operation on the environment.
The results of this program are intended to supplement the results of the Radiological Effluent Monitoring Program.
The REMP verifies that the measurable concentrations of radioactive materials and levels of radiation are no higher than expected based on the effluent measurements and modeling of the exposure pathways.
The program uses the guidance of Refs. 2, 4, 5,
6, and 7.
The following describes the environmental sampling categories of Table 6.3.1-1.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.3.1-1
Radiological Environmental Monitoring Program B 6.3.1 BASES REQUIREMENTS FOR OPERABILITY (continued)
Direct Radiation Pathway Thirty-four direct radiation monitoring stations are required.
One or two of these are to serve as control stations located in area(s) not impacted by direct radiation from the plant.
The other stations are to be located at various distances from the plant (as noted to Table 6.3.1-1) in order to obtain a representative measurement of possible direct radiation in the environment surrounding Columbia Generating Station.
These measurements are normally made with thermoluminescent dosimeter (TLDs).
- However, one or more instruments, such as a pressurized ion chamber, for measuring and recording dose rate continuously may be used in place of, or in addition to, integrating dosimeters.
For the purposes of Table 6.3.1-1, a TLD is considered to be one phosphor card with multiple readout areas; a phosphor card in a packet is considered to be equivalent to two or more dosimeters.
Film badges shall not be used as dosimeters for measuring direct radiation.
The frequency of analysis or readout for TLD systems will depend upon the characteristics of the specific system used and selected to obtain optimum dose information with minimal fading.
TLDs are to meet the requirements of Ref.
6 except for specified energy dependence response.
Airborne Pathway-Particulate/lodine Samples are required from 6 locations.
One of these locations is to be a control location located in a direction not expected to be impacted by plant airborne effluents.
The other five locations are to be indicator stations located in a direction that are most likely to be impacted by plant gaseous effluents.
Samples are obtained through the use of constant flow-rate sampling units that collect both particulate and iodine samples.
Gross beta, gamma isotopic and radioiodine analysis are required.
Waterborne Pathway-Surface Water An upstream and a downstream sample are required.
At Columbia Generating Station the upstream sample is considered the control sample.
It is taken from the plant (continued)
Columbia Generating Station B 6.3.1-2 Amendment 35, MAR 2002
Radiologi cal Envi ronmental Moni taring Program Radiological Environmental Monitoring Program B 6.3.1 BASES REQUIREMENTS Waterborne Pathway-Surface Water (continued)
FOR OPERABILITY water intake which is located upstream of the plant discharge into the river.
The downstream sample requirement allows for dilution in the mixing zone associated with the plant discharge line into the Columbia River.
- However, it is not feasible to perform flow-proportional composite sampling in the mixing zone area of the river downstream from the plant discharge point.
Therefore, the downstream sample is taken from the plant discharge prior to river dilution.
This provides a very conservative measurement.
Gamma isotopic, gross beta, and tritium analyses are required for these samples.
Waterborne Pathway-Ground Water Groundwater samples from one or two sources are required when the source is tapped for drinking or irrigation purposes in areas where the hydraulic gradient or recharge properties are suitable for contamination.
At Columbia Generating Station the deep well just north of the Reactor Building is sampled as it is a backup source of drinking water at the plant.
Two wells at WNP-1 that provide drinking water for that site are also sampled.
Gamma isotopic and tritium analysis are required.
Waterborn,!P'&+hway-Drinkinq Water One sample is required of each of one to three of the nearest xatr supplies that could be affected.
A sample is also required from a control location.
The primary indicator station for drinking water is the City of Richland Water Treatment Plant that obtains its drinking water from the Columbia River.
The control location is the plant intake water sampler that provides a sample of the Columbia River water upstream of the discharge line.
Gross beta, gamma isotopic, and tritium analysis is required periodically.
If the calculated dose from the consumption of water is greater than 1 mrem per year 1-131 analysis is also performed.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.3.1-3
Radiological Environmental Monitoring Program Radiological Environmental Monitoring Program B 6.3.1 BASES REQUIREMENTS Waterborne Pathway -
Sediment From Shoreline FOR OPERABILITY (continued)
One sample is required from a downstream area with existing or potential recreational value.
This sample is collected approximately one mile downstream from the plant effluent line.
Gamma isotopic analysis is required of this sample.
Ingestion-Milk Samples are required from milking animals in three locations within five kilometers having the highest dose potential.
At Columbia Generating Station there are no milking animals at this distance as the area inside a five kilometer radius is all on the Hanford Site.
In this case, a sample is required from milking animals in each of three areas between five and sixteen kilometers distant where doses are calculated to be greater than one mrem per year to the maximum organ and age group.
Even at this distance, the availability of samples is limited and may not be available at all times.
A sample from milking animals is also required at a control location, 30-50 kilometers distant and in the least prevalent wind direction.
Indicator samples are obtained from cattle across the Columbia River in Franklin County.
The control sample is obtained from the Sunnyside/Grandview area.
- However, it is sometimes difficult to obtain a control sample because most of the cattle in this area use feed from the area east of the plant.
This invalidates this milk as a control sample.
Gamma isotopic and 1-131 analysis are required.
In addition, if Cs-134 or Cs-137 is measured in an individual milk sample in excess of 30 pCi/liter, then Sr-90 analysis shall be performed.
Ingestion-Fish One sample of each of three recreationally important species (one anadromous and two resident) is required from the vicinity of the plant discharge.
A control sample, of the same three species is required from an area not influenced by the plant discharge.
Resident samples are taken from the vicinity of the plant discharge.
Anadromous species are obtained from the Ringold Fish Hatchery.
Control samples for resident fish are collected from the Snake River.
(continued)
Columbia Generating Station B 6.3.1-4 Amendment 35, MAR 2002
'Radiological Environmental Monitoring Program B 6.3.1 BASES REQUIREMENTS Ingestion-Fish (continued)
FOR OPERABILITY Anadromous control samples are obtained from the Lyon's Ferry Fish Hatchery on the Snake River.
Gamma isotopic analysis is required on the edible portions.
Ingestion-Food Products One sample of each principal class of food products is required from any area that is irrigated by water in which liquid plant wastes have been discharged.
In addition samples of three different kinds of broad leaf vegetation grown nearest each of two different offsite locations of highest predicted annual average ground-level D/0 are required if milk sampling is not performed.
A control sample of broad leaf vegetation grown 30-50 kilometers in the least prevalent wind direction if milk sampling is not performed is also required.
Garden produce is routinely obtained from farms or gardens using Columbia River water for irrigation.
One sample of a root crop, leafy vegetable, and a fruit should be collected each sample period if available.
Gamma isotopic analysis is required for all samples.
In addition, broad leaf vegetation requires an 1-131 analysis if milk sampling is not performed.
APPLICABILITY This RFO is applicable at all times since effluents can be released at any time.
COMPENSATORY Required Compensatory Measure A.1 requires any deviations MEASURES from the program to be reported in the next annual Radiological Environmental Operating Report. This allows the NRC to be aware of any samples not collected and analyzed in compliance with the program detailed in Table 6.3.1-1.
The Condition B note allows separate condition entry for each milk and fresh leafy vegetable sample.
If one or more of the milk and leafy vegetable samples are unavailable, a location for replacement samples must be identified within 30 days.
The new sample locations along with revised tables and figures must be submitted in the next Radiological Environmental Operating Report.
The NRC considers the sampling of milk and fresh leafy vegetables important and thus requires replacement sample locations to be identified within 30 days.
(continued)
Columbia Generating Station B 6.3.1-5 Amendment 35, MAR 2002
Radiological Environmental Monitoring Program B 6.3.1 BASES COMPENSATORY MEASURES (continued)
The Condition C note allows separate condition entry for each sample.
The first condition involves the detection of the concentration of any single radionuclide in the environment exceeding the value given in Table 6.3.1-2.
The concentrations given approximate the dose levels allowed by Appendix I or Ref. 1. The detection of this level of radioactivity in the environment requires a Special Report to the NRC within 30 days.
If more than one radionuclide is detected, the concentration level that requires a report is decreased.
The formula given in the footnote of Table 6.3.1-2 requires a report whenever the sum of the detected concentrations divided by the concentration limits is greater than one.
The Special Report must describe the corrective actions being taken to reduce the dose below those given in the Appendix I of Ref. 1 RFOs (RFOs 6.2.1.2, 6.2.2.2, and 6.2.2.3).
The methodology and parameters used to estimate the potential annual dose to a member of the public shall be indicated in this report.
Condition D involves the detection of radionuclides other than those listed on Table 6.3.1-2.
If these radionuclides are detected, a dose calculation is required to determine the annual dose that would result if this concentration were present in the environment for a year.
If the dose is equal to or greater than the limits given by RFOs 6.2.1.2, 6.2.2.2, or 6.2.2.3, the condition is reportable unless it can be shown that the radionuclides were not the result of Columbia Generating Station operation.
The Special Report must state the corrective actions being taken to reduce the dose below the limits and must be written in 30 days.
The NRC requires timely information on unexpected radionuclides in the environment.
The detection of these non Table 6.3.1.-2 radionuclides must also be reported in the Annual Radiological Environmental Operating Report.
In this report, the detection of any non Table 6.3.1-2 radionuclides regardless of the calculated dose and source of the radiation is to be reported.
The methodology and parameters used to estimate the potential annual dose to a member of the public shall be indicated in this report.
(continued)
Columbia Generating Station B 6.3.1-6 Amendment 35, MAR 2002
Radiological-Environmental Monitoring Program B 6.3.1 BASES (continued)
SURVEILLANCE This surveillance requires sampling and analysis presented REQUIREMENTS in Table 6.3.1-1 be performed to verify all environmental radiological conditions are within limits.
All sampling and analysis is to be performed according to the frequency given in the Table.
The detection capabilities for the analysis are given in Table 6.3.1-3.
The required detection capabilities for environmental sample analyses are tabulated in terms of the Lower Limits of Detection (LLDs).
The LLDs required by Table 6.3.1-3 are considered optimum for routine environmental measurements in industrial laboratories.
It should be recognized that the LLD is defined as an a priori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement.
The formula to be used for LLD is given in the definition section of this ODCM Appendix.
Detailed discussions of the LLD and other detections limits can be found in References 8, 9,
and 10.
REFERENCES
- 1.
10 CFR 50.
- 2.
- 3.
FSAR 15.0.3.
- 4.
Regulatory Guide 4.1, Rev.
- 1.
- 5.
- 6.
Regulatory Guide 4.13, Rev.
- 1.
- 7.
Regulatory Guide 4.15, Rev.
- 1.
- 8.
HASL Procedures Manuals, HASL-300 (revised annually).
- 9.
- Currie, L.A.
"Limits for Qualitative Detection and Quantitative Determination - Application to Radiochemistry" Anal.
Chem.
40, 586-93 (1968).
- 10.
- Hartwell, J.K. "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975).
Columbia Generating Station Amendment 35, MAR 2002 B 6.3.1-7
Land Use Census B 6.3.2 B 6.3 RADIOLOGICAL ENVIRONMENTAL MONITORING B 6.3.2 Land Use Census BASES BACKGROUND APPLICABLE SAFETY ANALYSES REQUIREMENTS FOR OPERABILITY The Land Use Census required by this RFO provides assurance that changes in the use of land in the unrestricted area are identified and that modifications to the radiological environmental monitoring program are made, if required, by the results of this census.
The best information from a door-to-door survey, from an aerial survey or from consulting with local agricultural authorities shall be used.
This census satisfies the requirements of Section IV.B.3 of Appendix I to Ref. 1.
Guidance for the Land Use Census is provided by Ref. 2.
This Land Use Census provides assurance that changing conditions in the environment surrounding Columbia Generatir-Station are identified.
This allows more accurate evaluation of the impact of radionuclide releases caused by normal operation and Anticipated Operational Transients.
Chapter 15, Accident Analysis, of the FSAR (Ref.
- 3) analyzes a number of anticipated process disturbances and component failures that have the potential of causing measurable environmental impact.
This RFO provides for a periodic update of the location of the nearcst milk animal, residence, and garden greater than 500 squar-ceet.
At Columbia Generating Station the closest residence is across the Columbia River at a distance of approximately 4 miles.
Because of the restrictions of the Hanford Site, the only land use area that has the potential for milk animals, residences, or gardens within 5 miles is a narrow strip of land just east of the Columbia River.
However, the Radiological Environmental Monitoring Program evaluates land use beyond the 5 mile limit.
Restricting the census to gardens of greater than 500 square feet provides assurance that significant exposure pathways via leafy vegetables will be identified and monitored since a garden of this size is the minimum required to produce the quantity (continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.3.2-1
Land Use Census B 6.3.2 BASES REQUIREMENTS (26 kg/year) of leafy vegetables assumed in Ref. 4 for FOR OPERABILITY consumption by a child.
To determine this minimum garden (continued) size, the following assumptions were made:
a) 20% of the garden was used for growing broad leaf vegetation (i.e., similar to lettuce and cabbage, and b) a vegetation yield of 2 kg/m 2.
APPLICABILITY The RFO is applicable at all times.
COMPENSATORY MEASURES If a Land Use Census is not conducted or if all required locations are not identified Compensatory Measure A.1 requires this condition to be reported in the next Annual Radiological Environmental Operating Report.
Condition B requires notification in the next submission of the Radioactive Effluent Release Report if the new Land Use Census identifies a new location of a milk animal, residence, or garden greater than 500 square feet and the calculated dose of dose commitment at this new location is greater than that calculated by the current census at the current locations.
Condition C is an escalation of Condition B.
It occurs if one of the newly identified census locations has a calculated dose greater than 120 percent of the dose from the current locations via the same exposure pathway.
In this case the new location must be added to the Radiological Environmental Monitoring Program within 30 days.
The compensatory measures also state that the sample location having the lowest calculated dose can be deleted from the Radiological Monitoring Program after October 31 of the year the newly discovered location was found.
In addition, the NRC is to be notified in the next Effluent Release Report.
This notification must include a revised figure(s) and table for the ODCM reflecting the new location(s).
The Compensatory Measures associated with Conditions B and C are structured to assure action is taken to evaluate and implement the results of the Land Use Census.
(continued)
Columbia Generating Station B 6.3.2-2 Amendment 35, MAR 2002
Land Use Census B 6.3.2 BASES (continued)
SURVEILLANCE REQUIREMENTS This surveillance requires a Land Use Census to be conducted every year.
The results of the Land Use Census are to be included in the annual Radiological Environmental Operating Report.
REFERENCES
- 1.
10 CFR 50.
- 2.
- 3.
FSAR 15.0.3.
- 4.
Columbia Generating Station Amendment 35, MAR 2002 B 6.3.2-3
Interlaboratory Comparison Program B 6.3.3 B 6.3 RADIOLOGICAL ENVIRONMENTAL MONITORING B 6.3.3 Interlaboratory Comparison Program BASES BACKGROUND The requirement for participation in an approved Interlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices are performed.
This comparison is part of the quality assurance program for environmental monitoring to demonstrate that the sampling results are valid for the purposes of Section IV.B.2 of Appendix I to Ref. 1.
APPLICABLE This Interlaboratory Comparison Program contributes to SAFETY ANALYSES safety by providing assurance that environmental sampling will be accurate and precise.
This allows more accurate evaluation of the impact of radionuclide releases caused by normal operation and Anticipated Operational Transients.
REQUIREMENTS The Interlaboratory Comparison Program is a major component FOR OPERABILITY of the quality assurance program for the Radiological Environmental Monitoring Program.
It involves the comparison of Columbia Generating Station analytical results obtained and compared to samples containing known concentrations of various radionuclides.
The program participates in the Environmental Measurements Laboratory (EML) intercomparison program.
It also participates in local and regional intercomparison studies.
APPLICABILITY This RFO is applicable at all times.
COMPENSATORY Failures associated with the Interlaboratory Comparison MEASURES Program must be reported to the NRC in the next Radiological Environmental Operating Report.
(continued)
Columbia Generating Station Amendment 35, MAR 2002 B 6.3.3-1
Interlaboratory Comparison Program B 6.3.3 BASES (continued)
SURVEILLANCE This surveillance requires analysis of radioactive material REQUIREMENTS supplied as part of the Interlaboratory Comparison Program.
REFERENCES
- 1.
Columbia Generating Station B 6.3.3-2 Amendment 35, MAR 2002