Revised Emergency Plan Implementing Procedures, EP-PS-244, Revision 6, Dose Assessment Staffer
ML030290311
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 01/20/2003
From:
Susquehanna
To:
Document Control Desk, Office of Nuclear Security and Incident Response
References
EP-PS-244, Rev 6
Download: ML030290311 (36)


Text

Jan.

20, 2003 Page 1

of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2003-3364 USER INFORMATION:

CA#:

0363 TRANSMITTAL INFORMATION:

01/20/2003 LOCATION:

DOCUMENT CONTROL DESK FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER "NUCSA-2)

<-PfHE FOLLOWING CHANGES-HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:

244 244 DOSE ASSESSMENT STAFFER REMOVE MANUAL TABLE OF CONTENTS DATE:

01/08/2003 ADD MANUAL TABLE OF CONTENTS DATE:

01/17/2003 CATEGORY:

PROCEDURES TYPE:

EP ID:

EP-PS-244 REPLACE:

REV:6 REPLACE:

REV:6 UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5

DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY.

FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

Tab 7 EP-PS-244-7

/

MIDAS OPERATING PROCEDURE TABLE OF CONTENTS SECTION PAGE A.

INTRODUCTION/SYSTEM STARTUP 2

EVALUATION OF UNMONITORED RELEASES FROM STATION I

BLOWOUT PANELS "

41 SSES BLOWOUT PANEL LOCATIONS 51 B.

MENU B: FORWARD CALCULATIONS 61 C.

MENU C: EVENT TREE NUREG-1228 CALCULATIONS 12 D.

MENU D: DEFAULT ACCIDENT CALCULATIONS 16 I E.

MENU E-W: BACK CALCULATIONS 19 I F.

DESCRIPTION OF INFORMATION PROVIDED ON THE MIDAS DOSE

SUMMARY

REPORT 24 J G.

INFORMATION FOR DISTANCES BETWEEN 10 AND 50 MILES 28 J H.

ACCIDENT DESCRIPTIONS 291 EP-AD-000-1 12, Revision 20, Page 1 of 35

Tab 7 EP-PS-244-7 A.

INTRODUCTION/SYSTEM STARTUP

1.

The following conventions are used in this procedure to describe computer operations:

a.

Bold, upper case text (i.e., CURRENT DATE), denotes text which appears on the screen.

b.

Underlined, uppercase text (i.e., LOGIN) denotes text to be typed.

c.

Bracketed, upper case text (i.e., [ENTER]), denotes special keys which are to be pressed.

d.

Most mouse selections can be made with a single click.

Single click RESET to cancel previous screen selections.

Double click RESET to back out of present menu.

Double click to EXIT menu.

2.

The met and vent spreadsheet will appear with all of the meteorological and ventilation release rate parameters across the top of the page. The current time period is highlighted in the left-hand column. The first time interval is 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> before the current time and the last time interval is 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> after the current time.

3.

All required meteorological and ventilation data for MIDAS can be obtained using the METNENT DATA ACQUISITION OPTIONS tab.

4.

To start MIDAS on a DOS computer:

a.

Turn ON each component (monitor, computer, and printer) of the computer system on which MIDAS is loaded.

b.

At the MIDAS logon screen, enter the password MIDAS and [ENTER].

c.

At the MIDAS MAIN MENU screen, select A: MIDAS (Dose Calculator) and [ENTER].

d.

The system will then display the CURRENT DATE. If the date is correct, press [ENTER]. If this date is incorrect, type the correct date using the format which is illustrated in the prompt and press [ENTER].

e.

The system will then display the CURRENT TIME, which is stored in the computer system's clock (24-hour clock format). If the time is correct, press [ENTER]. If this time is incorrect, type the correct time using the format which is illustrated in the prompt and press [ENTER].

EP-AD-000-1 12, Revision 20, Page 2 of 35

Tab 7 EP-PS-244-7

f.

The MIDAS logon screen will now appear for 20 seconds.

g.

The ACCIDENT MENU SELECTION screen will appear. Select the appropriate calculation option and CONFIRM your selection.

5.

To exit MIDAS on a DOS computer, double-click EXIT on each menu screen that appears. At the SECURITY MENU, press [F8] to log off.

6.

To start MIDAS on a Windows computer:

a.

Turn on each component (monitor, computer, and printer) of the computer system on which MIDAS is loaded.

b.

At the WINDOWS LOGIN Screen, press [CANCEL].

c.

On the System Desktop, double click on the MIDAS Icon.

d.

The system will then display the CURRENT DATE. If the date is correct, press [ENTER]. If the date is incorrect, type the correct date using the format which is illustrated in the prompt and press [ENTER].

e.

The system will then display the CURRENT TIME, which is stored in the computer system's clock (24-hour clock format). If the date is correct, press [ENTER]. If the date is incorrect, type the correct time using the format which is illustrated in the prompt and press [ENTER].

f.

The MIDAS logon screen will now appear for a short time.

g.

The ACCIDENT MENU SELECTION screen will appear. Select the appropriate calculation option and CONFIRM your selection.

7.

To exit MIDAS on a Windows computer, double-clock EXIT on each menu screen that appears until you return to the System Desktop.

a.

On the System Desktop, select START, SHUTDOWN, SHUTDOWN THE COMPUTER, and press [YES].

EP-AD-000-1 12, Revision 20, Page 3 of 35

Tab 7 EP-PS-244-7 EVALUATION OF UNMONITORED RELEASES FROM STATION BLOWOUT PANELS DIRECTIONS

1.
2.
3.

4.

Select the appropriate station blowout panel location.

Select an appropriate accident source term mix.

Use the corresponding design base release rates for input into MENU B.

Enter the release rates for one (1) fifteen-minute time period.

NOTE:

If Clad Failure or Fuel Melt mixes are selected, multiply the site total noble gas, I-131, and particulate release rates by the appropriate fraction of clad failure or fuel melt prior to entering the values onto the vent spreadsheet (e.g., the multiplier for 50% FUEL MELT would be 0.5).

[1] BLOWOUT PANEL LOCATION 13 ] DESIGN BASIS (SITE TOTAL) RELEASE RATES NOBLE GAS 1-131 PARTICULATE RCIC PUMP ROOM (pCi/min)

(pCi/min)

(pCi/min)

[2 ] ACCIDENT SOURCE TERM Normal Reactor Coolant Activity 1.2E+02*

1.8E+02 -

1.1 E+03 (LOCA) Reactor Depressurization-No FD 2.6E+06 8.4E+04 2.2E+04 (LOCA) 100% Clad Failure 2.1 E+09 2.4E+08 9.1E+07 (LOCA) 100% Fuel Melt 4.3E+10 1.3E+09 1.7E+09 HPCI PUMP ROOM (pCi/min)

(pCi/min)

(pCVminm)

Normal Reactor Coolant Activity 2.1 E+03*

3.2E+03 1.9E+04 (LOCA) Reactor Depressurization-No FD 4.6E+07 1.5E+06 3.8E+05 (LOCA) 100% Clad Failure 3.7E+10 4.3E+09 1.6E+09 (LOCA) 100% Fuel Melt 7.5E+11 2.3E+10 3.0E+10 HPCI/RCIC ROUTING AREA J

(lCi/min)

(pCi/min)

(pCi/min)

Normal Reactor Coolant Activity 3.2E+03*

4.9E+03 2.9E+04 (LOCA) Reactor Depressurization-No FD 7.OE+07 2.2E+06 5.8E+05 (LOCA) 100% Clad Failure 5.7E+10 6.5E+09 2.4E+09 (LOCA) 100% Fuel Melt 1.1 E+12 3.5E+10 4.6E+10 RWCU PENETRATION ROOM (pCi/min)

(pCi/min)

(pCVmm)

Normal Reactor Coolant Activity 7.3E+03*

5.8E+03 6.6E+04 (LOCA) Reactor Depressurization-No FD 1.6E+08 2.6E+06 1.3E+06 (LOCA) 100% Clad Failure 1.3E+1 1 7.6E+09 5.5E+09 (LOCA) 100% Fuel Melt 2.6E+12 4.1 E+1 0 1.0E+1 1 RB/TB MAIN STEAM TUNNEL, (pCi/min)

- (pCi/min)

(pCi/min)

Normal Reactor Coolant Activity 2.6E+04*

3.9E+04 2.3E+05 (LOCA) Reactor Depressurization-No FD 5.6E+08 1.8E+07 4.7E+06 (LOCA) 100% Clad Failure 4.6E+11 5.2E+10 1.9E+10 (LOCA) 100% Fuel Melt 9.1E+12 2.8E+11 3.7E+11 FD = FUEL DAMAGE Value less than that defining a release.

REFERENCE:

EC-RADN-1018, Evaluation of Unmonitored Releases from Station Blowout Panels, Revision 1, File R2-1.

EP-AD-000-1 12, Revision 20, Page 4 of 35

6 Kr m

r 00 00 zV Z

~

~

i; IjI-

~

14 ]l w 1 a ii!i m

N, r

~

Z 4;

~

0 CO

Tab 7 EP-PS-244-7 B.

MENU B: FORWARD CALCULATIONS REQUIRED INPUTS ENGINEERING OR OPERATIONS SUPPORT IS REQUESTED FOR THESE CALCULATIONS.

PLANT CONDITIONS TIME OF REACTOR SHUTDOWN RELEASE START TIME DURATION OF RELEASE PROJECTION TIME ACCIDENT SOURCE TERM SELECTION MET DATA 10 MWIND SPEED 10 MWIND DIRECTION STABILITY CLASS PRECIPITATION RATE VENT DATA SITE TOTAL NOBLE GAS RELEASE RATES SITE TOTAL 1-131 RELEASE RATES SITE TOTAL PARTICULATE RELEASE RATES

1.

The METNENT DATA CONTROL TABLE screen will appear.

a.

Select START NEW SCENARIO and then CONFIRM, OR

b.

If you have already initiated calculations and wish to modify either the existing met spreadsheet file or vent spreadsheet, select CURRENT SCENARIO EDIT and CONFIRM.

NOTE:

CURRENT SCENARIO EDIT will include releases/doses from previous time steps, if applicable.

c.

Other options are available in the lower right hand section of the display if you wish to RESET or change your initial selection or EXIT the screen.

EP-AD-000-1 12, Revision 20, Page 6 of 35

Tab 7 EP-PS-244-7

2.

The METEOROLOGICAL DATA spreadsheet will appear with all of the required meteorological parameters across the top of the page. Place the cursor on the data period corresponding to the start of release. Input the following met data:

NOTE 1:

If the met data remains the same for successive time periods, the operator need only enter the met data once. MIDAS will persist the data to future time periods automatically.

NOTE 2:

If a value is to be repeated in a field it can still be manually copied down the spreadsheet using the K (copy last) key while that value is highlighted.

-a.

In the column labeled 1OM SPD, enter the wind speed from the 10 meter onsite (primary) meteorological tower in MILES PER HOUR (MPH).

NOTE:

If the primary meteorological tower data is not available, refer to the Met Vent Data Acquisition Options tab for other options.

b.

In the column labeled 1 OM WD, enter the wind direction from the 10-meter onsite (primary) meteorological tower in DEGREES FROM (DEG FM).

c.

In the column labeled STAB CLS, enter the actual value for AT in DEGREES CENTIGRADE (preferred method) or the wind speed corrected stability class (Letter Code) if the primary tower data is not available. MIDAS will convert the letter entry to a numerical value.

d.

In the column labeled RAIN-LMH, enter the precipitation rate in INCHES PER 15 MINUTES (IN/15M). Divide the PICSY precipitation rate (inches/hr) by 4. If the precipitation rate is not available, estimation may be made by using the following table:

e.

Type X when all data has been entered to save the data and exit out of the meteorological spreadsheet.

EP-AD-000-1 12, Revision 20, Page 7 of 35 NO PRECIPITATION O(zero)

DRIZZLE or MIST LIGHT STEADY RAIN MEDIUM HEAVY DOWNPOUR HEAVY

Tab 7 EP-PS-244-7

3.

A WEATHER SELECTION screen will appear if any of the meteorological data inputs are missing from the spreadsheet.

a.

If this screen appears, select RESET until you have returned to the METNENT DATA CONTROL TABLE screen.

b.

Select CURRENT SCENARIO EDIT and enter any missing meteorological values on the spreadsheet.

c.

Type X when all data has been entered to save the data and exit out of the meteorological spreadsheet.

4.

-The vent (GASEOUS VENT AND FLOW) spreadsheet will appear next. Enter current vent data. The data entry for each 15-minute period is as follows:

NOTE:

Vent data may be entered in a regular numerical presentation (10000) or in scientific notation (1.OE+04).

a.

In the column labeled TOT NG RELEASE, enter the site total noble gas release rate in.Ci/min.

b.

In the column labeled TOT 1-131 RELEASE, enter the site total 1-131 release rate in jiCi/min.

c.

In the column labeled TOT P RELEASE, enter the site total particulate release rate in gCi/min.

d.

When the data entry is complete, press the X key to-save the information and exit the spreadsheet.

5.

From the ACCIDENT SOURCE TERM SELECTION screen, select an appropriate accident source term, then CONFIRM. Select RESET if you wish to change your previous selection.

If no specific information on the type of release is available from Engineering, use the following as a guide in the selection of appropriate accident source term.

a.

Obtain Reactor Power from Engineering, Operations, or as follows:

1)

From PICSY, select Unit #1 or Unit #2 formats to view affected unit.

2)

Type STA and press [ENTER].

3)

"Reactor Power" is in the top left section.

4)

Click on MET VENT to return to the Met/Vent data display.

EP-AD-000-1 12, Revision 20, Page 8 of 35

Tab 7 EP-PS-244-7

b.

If the reactor is operating at or greater than 10% power, select the ATWS source term.

c.

If reactor power is at less than 10%, select the LOCA (Clad Failure) source term.

d.

If conditions indicate a fuel handling incident and a release from the refueling floor (Reactor Building floor 818'), select Fuel Handling Accident.

6.

The RELEASE TIMING SELECTION screen will appear next. There are three lines to the screen.

a.

On Line 1, select TRIP DATE (date and time of reactor trip). Using the calendar wheel, enter the appropriate date and time of reactor trip.

CONFIRM to close the calendar wheel.

1)

The time of reactor trip must be equal to or earlier than the START OF RELEASE.

2)

The time of reactor trip can be set up to roughly one year (8,190 hours0.0022 days <br />0.0528 hours <br />3.141534e-4 weeks <br />7.2295e-5 months <br />) prior to the START OF RELEASE.

NOTE (1):

MIDAS assumes the reactor must be shutdown before a release can occur. The TRIP DATE triggers the start of decay for the accident mix.

NOTE (2):

Even during an ATWS, where a release is in-progress and the reactor has not shut down, a TRIP DATE must be entered to run MIDAS. It is recommended the same date and time for the START OF RELEASE be used for the TRIP DATE. Entering a date and time for reactor trip has no impact on decay of the ATWS mix.

b.

On Line 2, select START OF RELEASE. Using the calendar wheel, enter the appropriate date and time of the start of release. CONFIRM to close the calendar wheel.

1)

If START NEW SCENARIO was selected, the START OF RELEASE date/time entered should be the current date/time at I which you are starting the calculation.

EP-AD-000-1 12, Revision 20, Page 9 of 35

Tab 7 EP-PS-244-7

2)

If CURRENT SCENARIO EDIT was selected, the previously entered START OF RELEASE should still be used, if met/vent date have been entered for each 15-minute period since that START OF RELEASE. Otherwise, select RESET until START NEW SCENARIO is selected.

NOTE:

The START OF RELEASE is defined as the date and time of the first vent data entry.

c.

On Line 3, select REMAINING DURATION of the release. Using the NUMPAD enter the duration of release, in minutes, and select EN or press [ENTER] to close the numpad. If the duration of release is not known, use the default of 360 minutes, except that for blow-out panel calculations, the assumed release duration is 15 minutes.

NOTE:

The REMAINING DURATION (DURATION OF RELEASE) can use forecasted or persisted data for up to 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> into the future.

d.

Select CONFIRM to continue with the calculation or RESET to change any of your previous choices.

7.

The PPL

SUMMARY

DATA SELECTION screen allows the user to select different options for the MIDAS DOSE

SUMMARY

REPORT.

a.

Select the projection time from the left-hand column if other than the default of six hours is needed.

b.

Select the PEAK SECTOR dose rate option; then CONFIRM. If you wish to change any of your previous choices, select RESET.

NOTE:

The PEAK SECTOR is used to determine the highest dose rate in all 16 sectors. The alternate selection (CURRENT AFFECTED SECTOR) is applicable only when estimated dose rates from the current release period alone are requested by the RPC/DASU.

8.

After the calculations have completed, the MIDAS DOSE

SUMMARY

REPORT will be displayed on the screen.

a.

If you want to select a different projection time or sector designation from the PPL

SUMMARY

DATA SELECTION screen, select RESTART REPORT.

b.

If you wish to view additional report options, select CONTINUE and, on the next page, MORE REPORTS.

EP-AD-000-112, Revision 20, Page 10 of 35

Tab 7 EP-PS-244-7

c.

If you wish to continue with the next calculation, double click EXIT. This will return you to the ACCIDENT MENU SELECTION screen where the dose calculation process can be repeated using updated input values.

d.

If a hard copy is desired of any printout or plot displayed on the screen, press [PRINT SCRN].

NOTE:

If a hard-copy printout is made of the MIDAS DOSE

SUMMARY

REPORT, be sure to fill in the required information documenting the name of the dose calculator, reviewer, and date the calculation was performed.

EP-AD-000-1 12, Revision 20, Page 11 of 35

Tab 7 EP-PS-244-7 C.

MENU C: EVENT TREE NUREG-1228 CALCULATIONS REQUIRED INPUTS ENGINEERING OR OPERATIONS SUPPORT IS REQUESTED FOR THESE CALCULATIONS.

PLANT CONDITIONS RELEASE PATHWAY CORE CONDITION CONTAINMENT CONDITIONS FILTRATION PROJECTION TIME MET DATA 10 MWIND SPEED 10 MWIND DIRECTION STABILITY CLASS PRECIPITATION RATE

1.

The EVENT TREE NUREG-1228 SELECTION screen will appear.

a.

Using information provided by Engineering Support or Operations, select one cell in each row of the menu. When a cell in the current row is selected, the next row then appears.

NOTE:

Event tree menu selections, which include a definition of plant release parameters, are included (Section H) for each NUREG-1228 accident release scenario.

b.

[PRINT SCREEN] when final selections are made on the EVENT TREE NUREG-1228 SELECTION screen to document the calculation inputs.

NOTE:

Engineering Support or Operations concurrence with the selections may be documented by their representatives' signatures on the printout.

c.

CONFIRM entries to continue with the calculation or RESET if you wish to change any of your selections. You may also double-click EXIT to return to the ACCIDENT MENU SELECTION screen.

2.

The METNENT DATA CONTROL TABLE screen will appear.

a.

Select START NEW SCENARIO and then CONFIRM.

EP-AD-000-1 12, Revision 20, Page 12 of 35

Tab 7 EP-PS-244-7

b.

Other options are available in the lower right hand section of the display if you wish to RESET your initial entries or EXIT the screen.

3.

The METEOROLOGICAL DATA spreadsheet will appear with all of the required meteorological parameters across the top of the page.

NOTE:

Ensure met data is entered for the current time. MIDAS will persist the data to future time periods automatically.

a.

In the column labeled 10M SPD, enter the wind speed from the 10-meter onsite (primary) meteorological tower in MILES PER HOUR (MPH).

NOTE:

If the primary meteorological tower data is not available, refer to the Met Vent Data Acquisition Options tab for other options.

b.

In the column labeled 1OM WD, enter the wind direction from the 10-meter onsite (primary) meteorological tower in DEGREES FROM (DEG FM).

c.

In the column labeled STAB CLS, enter the actual value for AT in DEGREES CENTIGRADE (preferred method) or the wind speed corrected stability class (Letter Code) if the primary tower data is not available. MIDAS will convert the letter entry to a numerical value.

d.

In the column labeled RAIN-LMH, enter the precipitation rate in INCHES PER 15 MINUTES (IN/15M). Divide the PICSY precipitation rate (inches/hr) by 4. If the precipitation rate is not available, estimation may be made by using the following table:

NO PRECIPITATION O(zero)

DRIZZLE or MIST LIGHT STEADY RAIN MEDIUM HEAVY DOWNPOUR HEAVY

e.

Type X when all data has been entered to save the data and exit out of the meteorological spreadsheet.

4.

A WEATHER SELECTION screen will appear if any of the meteorological data inputs are missing from the spreadsheet.

a.

If this screen appears, select RESET until you have returned to the METNENT DATA CONTROL TABLE screen.

EP-AD-000-1 12, Revision 20, Page 13 of 35

Tab 7 EP-PS-244-7

b.

Select CURRENT SCENARIO EDIT and enter any missing meteorological values on the spreadsheet.

c.

Type X when all data has been entered to save the data and exit out of the meteorological spreadsheet.

5.

The PPL

SUMMARY

DATA SELECTION screen allows the user to select different options for the MIDAS DOSE

SUMMARY

REPORT.

a.

Select the projection time from the left-hand column if other than the default of six hours is needed.

-b.

Select the PEAK SECTOR dose rate option; then CONFIRM. If you wish to change any of your previous choices, select RESET.

NOTE:

The PEAK SECTOR is used to determine the highest dose rate in all 16 sectors. The alternate selection (CURRENT AFFECTED SECTOR) is applicable only when estimated dose rates from the current release period alone are requested by the RPC/DASU.

6.

After the calculations have completed, the MIDAS DOSE

SUMMARY

REPORT will be displayed on the screen.

a.

If you want to select a different projection time or sector designation from the PPL

SUMMARY

DATA SELECTION screen, select RESTART PROGRAM.

b.

If you wish to view additional report options, select CONTINUE and, on the next page, MORE REPORTS.

c.

If you wish to continue with the next calculation, double click EXIT. This will return you to the ACCIDENT MENU SELECTION screen where the dose calculation process can be repeated using updated input values.

d.

If a hard copy is desired of any printout or plot displayed on the screen, press [PRINT SCRN].

NOTE:

If a hard-copy printout is made of the MIDAS DOSE

SUMMARY

REPORT, be sure to fill in the required information documenting the name of the dose calculator, reviewer, and date the calculation was performed.

EP-AD-000-1 12, Revision 20, Page 14 of 35

Tab 7 EP-PS-244-7

7.

Adjust the results to reflect the percentage of clad failure or fuel melt applicable to the current scenario.

a.

Multiply calculated dose rates and doses by the appropriate fraction of clad failure or fuel melt. Example: The multiplier for 50% FUEL MELT would be 0.5.

EP-AD-O00-1 12, Revision 20, Page 15 of 35

Tab 7 EP-PS-244-7 D.

MENU D: DEFAULT ACCIDENT CALCULATIONS REQUIRED INPUTS ENGINEERING OR OPERATIONS SUPPORT IS REQUESTED FOR THESE CALCULATIONS.

MET DATA 1OMWINDSPEED 10 M WIND DIRECTION STABILITY CLASS PRECIPITATION RATE SOURCE TERM ACCIDENT SOURCE TERM SELECTION PERCENT OF CLAD FAILURE OR FUEL MELT PROJECTION TIME

1.

The METNVENT DATA CONTROL TABLE screen will appear.

a.

Select START NEW SCENARIO and then CONFIRM.

b.

Other options are available in the lower right hand section of the display if f you wish to RESET your initial entries or EXIT the screen.

2.

The METEOROLOGICAL DATA spreadsheet will appear with all of the required meteorological parameters across the top of the page.

NOTE:

Ensure met data is entered for the current time. MIDAS will persist the data to future time periods automatically.

a.

In the column labeled 10M SPD, enter the wind speed from the 10-meter onsite (primary) meteorological tower in MILES PER HOUR (MPH).

NOTE:

If the primary meteorological tower data is not available, refer to the Met Vent Data Acquisition Options tab for other options.

b.

In the column labeled 10M WD, enter the wind direction from the 10-meter onsite (primary) meteorological tower in DEGREES FROM (DEG FM).

EP-AD-000-1 12, Revision 20, Page 16 of 35

Tab 7 EP-PS-244-7

c.

In the column labeled STAB CLS, enter the actual value for AT in DEGREES CENTIGRADE (preferred method) or the wind speed corrected stability class (Letter Code) if the primary tower data is not available. MIDAS will convert the letter entry to a numerical value.

d.

In the column labeled RAIN-LMH, enter the precipitation rate in INCHES PER 15 MINUTES (IN/15M). Divide the PICSY precipitation rate (inches/hr) by 4. If the precipitation rate is not available, estimation may be made by using the following table:

NO PRECIPITATION O(zero)

DRIZZLE or MIST LIGHT STEADY RAIN MEDIUM HEAVY DOWNPOUR HEAVY

e.

Type X when all data has been entered to save the data and exit out of the meteorological spreadsheet.

3.

A WEATHER SELECTION screen will appear if any of the meteorological data inputs are missing from the spreadsheet.

a.

If this screen appears, select RESET until you have returned to the METNENT DATA CONTROL TABLE screen.

b.

Select CURRENT SCENARIO EDIT and enter any missing meteorological values on the spreadsheet.

c.

Type X when all data has been entered to save the data and exit out of the meteorological spreadsheet.

4.

From the ACCIDENT SOURCE TERM SELECTION screen, select an appropriate accident source term, then CONFIRM.

5.

A PERCENT FAILURE FOR LOCA screen will appear if the clad failure or fuel melt accident source term is selected. Input the percent of clad failure or fuel melt using the numpad and CONFIRM.

6.

The PPL

SUMMARY

DATA SELECTION screen allows the user to select different options for the MIDAS DOSE

SUMMARY

REPORT.

a.

Select the projection time from the left-hand column if other than the default of six hours is needed.

EP-AD-000-1 12, Revision 20, Page 17 of 35

Tab 7 EP-PS-244-7

b.

Select the PEAK SECTOR dose rate option; then CONFIRM. If you wish to change any of your previous choices, select RESET.

NOTE:

The PEAK SECTOR is used to determine the highest dose rate in all 16 sectors. The alternate selection (CURRENT AFFECTED SECTOR) is applicable only when estimated dose rates from the current release period alone are requested by the RPC/DASU.

7.

After the calculations have completed, the MIDAS DOSE

SUMMARY

REPORT will be displayed on the screen.

-a.

If you want to select a different projection time or sector designation from the PPL

SUMMARY

DATA SELECTION screen, select RESTART PROGRAM.

b.

If you wish to view additional report options, select CONTINUE and, on the next page, MORE REPORTS.

c.

If you wish to continue with the next calculation, double click EXIT. This will return you to the ACCIDENT MENU SELECTION screen where the dose calculation process can be repeated using updated input values.

d.

If a hard copy is desired of any printout or plot displayed on the screen, press [PRINT SCRN].

NOTE:

If a hard-copy printout is made of the MIDAS DOSE

SUMMARY

REPORT, be sure to fill in the required information documenting the name of the dose calculator, reviewer, and date the calculation was performed.

EP-AD-000-1 12, Revision 20, Page 18 of 35

Tab 7 EP-PS-244-7 E.

MENU E-W: BACK CALCULATIONS REQUIRED INPUTS ENGINEERING OR OPERATIONS SUPPORT IS REQUESTED FOR THESE CALCULATIONS.

PLANT CONDITIONS TIME OF REACTOR SHUTDOWN RELEASE START TIME DURATION OF RELEASE ACCIDENT SOURCE TERM SELECTION PROJECTION TIME MET DATA 10 MWIND SPEED 10 M WIND DIRECTION STABILITY CLASS PRECIPITATION RATE FIELD DATA 3 FT (CW) SURVEY METER READING DISTANCE FROM PLANT IODINE CARTRIDGE NET CPM OR DEFAULT IODINE MIX

1.

The METNENT DATA CONTROL TABLE screen will appear.

a.

Select START NEW SCENARIO and then CONFIRM.

b.

If you have already initiated calculations and wish to modify the existing met spreadsheet file, select CURRENT SCENARIO EDIT and CONFIRM.

c.

Other options are available in the lower right hand section of the display if you wish to RESET your initial entries or EXIT the screen.

EP-AD-000-112, Revision 20, Page 19 of 35

Tab 7 EP-PS-244-7

2.

The METEOROLOGICAL DATA spreadsheet will appear with all of the required meteorological parameters across the top of the page.

NOTE:

Ensure met data is entered for the current time. MIDAS will persist the data to future time periods automatically.

a.

In the column labeled IOM SPD, enter the wind speed from the 10-meter onsite (primary) meteorological tower in MILES PER HOUR (MPH).

NOTE:

If the primary meteorological tower data is not available, refer to the Met Vent Data Acquisition Options tab for other options.

-b.

In the column labeled 1OM WD, enter the wind direction from the 10-meter onsite (primary) meteorological tower in DEGREES FROM (DEG FM).

c.

In the column labeled STAB CLS, enter the actual value for AT in DEGREES CENTIGRADE (preferred method) or the wind speed corrected stability class (Letter Code) if the primary tower data is not available. MIDAS will convert the letter entry to a numerical value.

d.

In the column labeled RAIN-LMH, enter the precipitation rate in INCHES PER 15 MINUTES (IN/15M). Divide the PICSY precipitation rate (inches/hr) by 4. If the precipitation rate is not available, estimation may be made by using the following table:

NO PRECIPITATION O(zero)

DRIZZLE or MIST LIGHT STEADY RAIN MEDIUM HEAVY DOWNPOUR HEAVY

e.

Type X when all data has been entered to save the data and exit out of the meteorological spreadsheet.

3.

A WEATHER SELECTION screen will appear if any of the meteorological data inputs are missing from the spreadsheet.

a.

If this screen appears, select RESET until you have returned to the METNENT DATA CONTROL TABLE screen.

b.

Select CURRENT SCENARIO EDIT and enter any missing meteorological values on the spreadsheet.

c.

Type X when all data has been entered to save the data and exit out of the meteorological spreadsheet.

EP-AD-000-1 12, Revision 20, Page 20 of 35

Tab 7 EP-PS-244-7

4.

From the ACCIDENT SOURCE TERM SELECTION screen, select an appropriate accident source term, then CONFIRM.

If no specific information on the type of release is available from Engineering, use the following as a guide in the selection of an appropriate accident source term:

a.

Obtain Reactor Power from Engineering, Operations, or as follows:

1)

From PICSY, select Unit #1 or Unit #2 formats to view affected unit.

2)

Type STA and press [ENTER].

3)

"Reactor Power" is in the top left section.

4)

Click on MET VENT to return to the Met/Vent data display.

b.

If the reactor is operating at or greater than 10% power, select the ATWS source term.

c.

If reactor power is at less than 10%, select the LOCA (Clad Failure) source term.

d.

If conditions indicate a fuel handling incident and a release from the refueling floor (Reactor Building floor 818'), select Fuel Handling Accident.

5.

The next screen is the FIELD MONITOR PARAMETER SELECTION screen.

Select the appropriate cells and input the information requested using the numpad on the screen or enter the data using the computer keyboard. Once the data entry is complete, CONFIRM to continue with the calculation.

a.

Enter Field Team or ERMS Fixed Monitor gamma (EDE) dose rate whichever is appropriate.

b.

Enter the distance of the Field Team or Fixed Monitor from the plant as noted on the RMS Report or for the on-site team as noted on Table 4 of EP-AD-000-124.

c.

If iodine air sample data is available, enter either the IODINE CARTRIDGE reading in net counts per minute or an IODINE CONCENTRATION value in gCi/cc. A zero (0) value may be entered for the net count per minute or p.Ci/cc measurement, if indicated.

d.

If iodine data is not available, select the DEFAULT MIX option to characterize the iodine source term.

EP-AD-000-1 12, Revision 20, Page 21 of 35

Tab 7 EP-PS-244-7

6.

On the RELEASE TIMING SELECTION screen, enter the estimated remaining duration for the release, then CONFIRM. If the duration of release is not known, use the default of 360 minutes.

7.

The PPL

SUMMARY

DATA SELECTION screen allows the user to select different options for the MIDAS DOSE

SUMMARY

REPORT.

a.

Select the projection time from the left-hand column if other than the default of six hours is needed.

b.

Select the PEAK SECTOR dose rate option; then CONFIRM. If you wish to change any of your previous choices, select RESET.

NOTE:

The PEAK SECTOR is used to determine the highest dose rate in all 16 sectors. The alternate selection (CURRENT AFFECTED SECTOR) is applicable only when estimated dose rates from the current release period alone are requested by the RPC/DASU.

8.

After the calculations have completed, the MIDAS DOSE

SUMMARY

REPORT will be displayed on the screen.

a.

If you want to select a different projection time or sector designation from the PPL

SUMMARY

DATA SELECTION screen, select RESTART PROGRAM.

b.

If you wish to view additional report options, select CONTINUE and, on the next page, MORE REPORTS.

c.

If you wish to continue with the next calculation, double click EXIT. This will return you to the ACCIDENT MENU SELECTION screen where the dose calculation process can be repeated using updated input values.

d.

If a hard copy is desired of any printout or plot displayed on the screen, press [PRINT SCRN].

NOTE:

If a hard-copy printout is made of the MIDAS DOSE

SUMMARY

REPORT, be sure to fill in the required information documenting the name of the dose calculator, reviewer, and date the calculation was performed.

EP-AD-000-1 12, Revision 20, Page 22 of 35

Tab 7 EP-PS-244-7

e.

Remote Monitoring System perimeter monitoring location dose rates can be displayed by MIDAS using the perimeter monitoring dose rate screen option.

NOTE:

The displayed values are only numeric dose estimates based on MIDAS calculations. They are not "real-time" readings from the perimeter monitor system.

Directions for accessing the MIDAS perimeter monitor dose rate screen option are as follows:

1)

At the MIDAS DOSE

SUMMARY

REPORT screen, select CONTINUE.

2)

On the next screen select MORE REPORTS.

3)

From the MORE REPORTS SELECTION screen, select FM GAMMA DOSE RATE PLOT and CONFIRM.

4)

From the REPORT PARAMETER SELECTION screen, choose the appropriate projection time and CONFIRM.

5)

From the MAP SELECTION screen, select MAP SCALE and input 1.25 miles, then CONFIRM.

6)

On the next screen, select MAP FEATURES.

7)

On the next screen, select CALCULATED PERIMETER MON DOSE RATES and CONFIRM.

8)

To exit, select CONTINUE, MORE REPORTS, and EXIT.

EP-AD-000-1 12, Revision 20, Page 23 of 35

Tab 7 EP-PS-244-7 F.

DESCRIPTION OF INFORMATION PROVIDED ON THE MIDAS DOSE

SUMMARY

REPORT

1.

PRINT DATE/TIME Date and time MIDAS DOSE

SUMMARY

REPORT was printed.

2.

CURRENT TIME PERIOD Current meteorological time period used for dose projections provided on quarter hour increments to match met spreadsheet entries.

3.

-REACTOR SHUTDOWN Date and time of reactor shutdown.

4.

START OF RELEASE This is the date and time of first dose calculation as indicated by the first positive vent release rate value entered on the vent data spreadsheet or if the vent spreadsheet is not used, the date and time of the met data used for the current projection period.

NOTE:

For MENU C: NUREG-1228 CALCULATIONS, MENU D:

DEFAULT CALCULATIONS, and MENU E-W: BACK CALCULATIONS, it is conservatively assumed that the date and time of reactor shutdown is concurrent with the start of release.

5.

MENU SELECTION Identifies the dose calculation option used for the current dose projection summary report. Choice of four options:

MENU B: FORWARD CALCULATIONS MENU C: NR-1228 CALCULATIONS MENU D: DEFAULT CALCULATIONS MENU E-W: BACK CALCULATIONS EP-AD-O00-112, Revision 20, Page 24 of 35

Tab 7 EP-PS-244-7

6.

SOURCE TERM Identifies the source term used for the current dose projection summary report calculations. Choice of six options:

ATWS-Normal Reactor Coolant Activity (UNDECAYED)

Normal Reactor Coolant Activity (DECAYED)

(LOCA) Coolant Activity Leak with Depressurization Spike-No Fuel Damage (LOCA) Cladding Failure-Gap Release (LOCA) Fuel Melt-Early In-Vessel Release Fuel Handling Accident

7.

-MET DATA Meteorological data (wind speed, wind direction, stability class, and precipitation rate) used for the summary report dose projections.

8.

CURRENT AFFECTED SECTOR OR PEAK SECTOR DOSE RATES This table provides the TEDE, EDE, and THYROID CDE dose rates calculated at the OSCAR and EPB distances. These rate calculations are based on a variable projection/integration period for the current affected sector or peak sector.

9.

PROJECTED DOSES This table provides a TEDE and THYROID CDE dose projection calculated at the OSCAR, EPB, 2-mile, and 10-mile distances for varying projection times. The projection time will appear in the header line e.g., 4 HOUR PROJECTED DOSES on the MIDAS DOSE

SUMMARY

REPORT. The sector designation for this dose projection is based on the maximum calculated dose determined from all sixteen sectors for the given projection time. Information for distances between 10 and 50 miles is available using the "More Reports" feature.

10.

CALCULATEDIREVIEWED BY The sign-off for review of calculation results is done for documentation purposes.

The intended review does not necessarily mean an independent verification of each input to the calculation but more an interactive discussion between the RPC/HP Level II Dose Calculator and/or DASU/DAST (or dose calculator) to ensure the calculated results are reasonable based on current plant and environmental information.

This review should occur before the calculated results are used for any emergency classification determinations or protective action recommendations.

EP-AD-000-112, Revision 20, Page 25 of 35

Tab 7 EP-PS-244-7

11.

COMMENTS Section added to provide space for additional statements of qualification or background information pertaining to the dose projections.

EP-AD-000-1 12, Revision 20, Page 26 of 35

Tab 7 EP-PS-244-7 MIDAS DOSE

SUMMARY

REPORT SPRINT DATE/'TIE:

8/19/97 11:25 CURRENT TIME PEIOD:

9ej997 11:3g MIDAS DOSE

SUMMARY

REPORT SREACTOR SHUTDOWN:

8119o97 18:53 WIND SPEED (MPH):

5 START OF RfELEASE:

8/19/97 18:53 WIND FROM (DEC):

120 CESE)

HEM SELECTION:

FORIWARD CALCULATIONS STABILITY CLASS:

D SOURCE TEIM:

LOCA (CLAD FAILURE)

PRECIPITATION:

NO CURRENT (SITE TOTAL)

RELEASE RATE (uCi/stin)

NOBLE CAS 1--131 FART ICULATES 6.98E+99 9.96E+J81 9.96E÷81 CURRENT~~~~.

AFETDSCORDS AE UNITS DOSE RATE I ArFE C0494^-3 SEC TEDE RATE 883.42 NH KDVE ]NElT'-'

883.4 I

THV C.22 RATE DOSE RATE AFFECTED (Crn cwf*,)

SECTOR 775.98 NNH 775.98 8.16 CALCULATED BY:

REUIEWED BY:

COMMENTS:

DATE:

DATE:

I T52XJfl I~~E

+-I dHINUE Il EP-AD-000-1 12, Revision 20, Page 27 of 35 t©l

.. _-L L;

I

-- ?--

I I

II

Tab 7 EP-PS-244-7 G.

INFORMATION FOR DISTANCES BETWEEN 10 AND 50 MILES

1.

From the MIDAS DOSE

SUMMARY

REPORT screen, select CONTINUE and, on the next page, MORE REPORTS.

2.

Select TEDE 4-DAY DOSE REPORT or THYROID CDE DOSE REPORT, depending on which PAR guide has been exceeded at the 10-mile distance.

3.

On the REPORT PARAMETER SELECTION screen, select PROJECTION TIME until the appropriate PROJECTION TIME (0.25, 4, 6, or 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />) is displayed on the screen; then select CONFIRM.

4.

-The screen will now display projected doses at the EPB and at 2, 5, 10, 25, and 50 miles. To obtain finer increments of distance, select CONTINUE until the desired range of distances is displayed.

NOTE:

An objective is to determine the approximate distance from the plant at which dose projections are less than 1 rem TEDE and 5 rem THYROID CDE. A PAR is then likely to be issued to the next furthest 5-mile distance increment from the plant.

Example:

A PAR for distances to 30 miles may be selected if projected doses become less than the PAG values (1 rem TEDE, 5 rem THYROID CDE) between 25 and 30 miles from the plant.

EP-AD-000-1 12, Revision 20, Page 28 of 35

Tab 7 EP-PS-244-7 H.

ACCIDENT DESCRIPTIONS DEFAULT ACCIDENT DESCRIPTIONS (MENU B AND MENU D)

1.

NORMAL REACTOR COOLANT ACTIVITY This accident scenario is defined as the release of reactor coolant system liquid and steam activity from the primary coolant system with no damage to the fuel and no activity spiking. The source term for this accident is normal reactor coolant system liquid and steam activity.

2.

-LOCA (RX DP-NO FD)

This accident scenario is defined as the release of reactor coolant system liquid and steam activity from the primary coolant system. Depressurization of the primary coolant system is assumed, resulting in an activity spike in the reactor coolant. The source term for this accident is normal reactor coolant liquid and steam activity plus the depressurization activity spike. There is no fuel damage.

3.

LOCA (CLAD FAILURE)

This accident scenario is defined as a Loss-of-Coolant Accident which results in damage to the reactor fuel cladding. The source term for this accident is normal reactor coolant liquid and steam activity and a percentage of the activity in the fuel clad gap. For Menu D calculations, that percentage is entered as part of the calculation process. For Menu B calculations, the valid vent data entered define the severity of the event.

4.

LOCA (FUEL MELT)

This accident scenario is defined as a Loss-of-Coolant Accident which results in damage to the reactor fuel. The source term for this accident is normal reactor coolant liquid and steam activity and a percentage of the activity in the reactor fuel. For Menu D calculations, that percentage is entered as part of the calculation process. For Menu B calculations, the valid vent data entered define the severity of the event.

5.

FUEL HANDLING ACCIDENT This accident scenario is defined as a fuel handling accident which results in the release of spent fuel activity. The source term for this accident is spent fuel gap activity assuming a decay time after shutdown of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

EP-AD-000-1 12, Revision 20, Page 29 of 35

Tab 7 EP-PS-244-7

6.

ATWS This accident scenario is used for releases from a reactor unit continuing to operate at or greater than 10% power. The source term for this accident is normal reactor coolant system liquid and steam activity. The source term is undecayed; that is, no reactor trip is assumed to have occurred.

NOTE (1):

-NOTE (2):

For Menu D calculations, design basis assumptions are utilized.

For example, design basis leakage rates are assumed and iodine filtration efficiency of 99% is assumed in those pathways for which filters are in place.

The source term for Menu D accident types is fixed. Release rate is calculated by MIDAS by dividing the total activity released by a predetermined release duration (6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> for all but fuel handling accidents, for which release duration is 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />).

NUREG 1228 ACCIDENT TYPES (MENU C)

1.

LOCA-DRYWELL RELEASE This accident is a Loss-of-Coolant Accident with an activity release into the drywell which bypasses the suppression pool for which filtration of activity by the Standby Gas Treatment System takes place before release to the environment.

2.

LOCA - WETWELL RELEASE This accident is a Loss-of-Coolant Accident with an activity release through the suppression pool for which filtration of activity by the Standby Gas Treatment System takes place before release to the environment.

3.

LOCA - CONTAINMENT BYPASS RELEASE This accident is a Loss-of-Coolant Accident with an activity release to the environment that bypasses the containment and the Standby Gas Treatment System.

4.

ZIRCALLOY FIRE IN ONE THREE MONTH OLD BATCH This accident is a zircalloy fire in spent fuel that results in an activity release similar to a core melt. It assumes that the activity is filtered by the Standby Gas Treatment System prior to release.

EP-AD-000-1 12, Revision 20, Page 30 of 35 I

Tab 7 EP-PS-244-7

5.

SPENT FUEL GAP RELEASE This accident is a release of fuel gap activity from the spent fuel pool with treatment by the Standby Gas Treatment System prior to release.

NOTE:

Menu C (from NUREG-1 228 Event Tree Analyses) is used to relatively quickly provide a bounding estimate of offsite dose, for situations where there are substantial uncertainties in prediction of source term and any resultant doses.

EP-AD-000-1 12, Revision 20, Page 31 of 35

Tab 7 EP-PS-244-7 NUREG 1228 MENU STRUCTURE FOR DRYWELL RELEASE WE1'ELL RELEASE CONTAINMENT

-BYPASS

.RELEASE

" SPENT FUEL "POOL RELEASE (100% Fuel Melt)

IN-VESSEL SEVERE DAMAGE UNCOVERED

>30MIN (100% Fuel Melt)

VESSEL MELT THROUGH SPRAY ON SPRAY OFF HOLDUP TIME

<1 HOUR CATASTROPHIC CONTAINMENT FAILURE HOLDUP TIME 2-12 HOURS (DEFAULT)

HOLDUP TIME 24 HOURS DELAYED RELEASE Status of Drywell Containment Spray Drywell Holdup Time:

Time from Release into Containment to Start of Release into

-Environment(')

LEAK RATE 100%/HOUR LEAK RATE 100%/DAY UNFILTERED LEAK RATE 100%/DAY FILTERED DESIGN LEAK RATE UNFILTERED DESIGN LEAK RATE FILTERED Catastrophic Containment Failure Failure to Isolate Containment 1%/Day (1)

HOLDUP TIME is defined as drywell holdup time prior to release to the environment.

During this time period, credit is taken for drywell airborne activity removal due to plateout by natural processes and water sprays prior to release to the environment.

EP-AD-000-1 12, Revision 20, Page 32 of 35 DRYWELL RELEASE (100% Clad Failure)

GAP RELEASE UNCOVERED 15-30 MIN Core Condition I -

i

Tab 7 EP-PS-244-7 NUREG 1228 MENU STRUCTURE FOR WETWELL RELEASE DRYWELL "RELEASE (100% Clad Failure)

GAP RELEASE UNCOVERED 15-30 MIN SATURATED I

HOLDUP TIME

<1 HOUR CATASTROPHIC CONTAINMENT FAILURE WETWELL RELEASE (100% Fuel Melt)

IN-VESSEL SEVERE DAMAGE UNCOVERED

> 30 MIN CONTAINMENT

-BYPASS

'RELEASE (100% Fuel Melt)

VESSEL MELT THROUGH SUB-COOLED HOLDUP TIME 2-12 HOURS (DEFAULT)

HOLDUP TIME 24 HOURS DELAYED RELEASE "SPENT FUEL POOL RELEASE Core Condition Conditions in Suppression Pool Wetwell Holdup Time:

Time from Release into Wetwell to Start of Release into Environment(1)

LEAK RATE 100%/HOUR LEAK RATE 100%/DAY UNFILTERED LEAK RATE 100%/DAY FILTERED DESIGN LEAK RATE UNFILTERED DESIGN LEAK RATE FILTERED Catastrophic Containment Failure Failure to Isolate Containment (1)

HOLDUP TIME is defined as wetwell holdup time prior to release to the environment.

During this time period, credit is taken for wetwell airborne activity removal due to plateout by natural processes and water sprays prior to release to the environment.

EP-AD-000-112, Revision 20, Page 33 of 35 1%/Day 3/4

-

Tab 7 EP-PS-244-7 NUREG 1228 MENU STRUCTURE FOR CONTAINMENT BYPASS RELEASE DRYWELL RELEASE (100% Clad Failure)

GAP RELEASE UNCOVERED 15-30 MIN UNFILTERED RELEASE RATE 100%/HOUR Catastrophic Containment Failure WETWELL RELEASE (100% Fuel Melt)

IN-VESSEL SEVERE DAMAGE UNCOVERED

> 30 MIN FILTERED RELEASE RATE 100%/DAY Failure to Isolate Containment CONTAINMENT BYPASS RELEASE (100% Fuel Melt)

VESSEL MELT THROUGH TYPICAL DESIGN RELEASE RATE "SPENT FUEL POOL RELEASE Core Condition Is Release Filtered?

Release Rate, in Terms of Percent of Core Inventory 1%/Day EP-AD-000-1 12, Revision 20, Page 34 of 35

Tab 7 EP-PS-244-7 NUREG 1228 MENU STRUCTURE FOR SPENT FUEL POOL RELEASE ZIRCALLOY FIRE IN ONE 3 MONTH OLD BATCH GAP RELEASE FROM ONE 3 MONTH OLD BATCH SPRAY OFF (Default)

HOLDUP TIME 2-12 HOURS (DEFAULT)

GAP RELEASE FROM 15 BATCHES (TOTAL POOL)

SPENT FUEL POOL RELEASE Condition of Spent Fuel Status of Containment Spray into Pool Time from Release from Fuel to Start of Release into Environment(1)

LEAK RATE 100%/HOUR LEAK RATE 100%/DAY UNFILTERED LEAK RATE 100%/DAY FILTERED Release Rate, in Terms of Percent of Source InVentory Catastrophic Failure of Secondary Containment (1)

HOLDUP TIME for a spent fuel pool release is defined as reactor building holdup time prior to release to the environment. During this time period, credit is taken for reactor building airborne activity removal due to plateout by natural processes and water sprays prior to release to the environment.

EP-AD-000-1 12, Revision 20, Page 35 of 35 HOLDUP TIME

<1 HOUR CATASTROPHIC FAILURE OF REACTOR BUILDING