ML030090478
| ML030090478 | |
| Person / Time | |
|---|---|
| Site: | River Bend |
| Issue date: | 01/06/2003 |
| From: | Gramm R NRC/NRR/DLPM/LPD4 |
| To: | Hinnenkamp P Entergy Operations |
| Webb M, NRR/DLPM, 415-1347 | |
| Shared Package | |
| ml030090515 | List: |
| References | |
| TAC MB5094 | |
| Download: ML030090478 (3) | |
Text
January 6, 2003 Mr. Paul D. Hinnenkamp Vice President - Operations Entergy Operations, Inc.
River Bend Station P. O. Box 220 St. Francisville, LA 70775
SUBJECT:
RIVER BEND STATION, UNIT 1 - RE: DRAFT SAFETY EVALUATION FOR PROPOSED 1.7 PERCENT INCREASE IN LICENSED POWER LEVEL (TAC NO. MB5094)
Dear Mr. Hinnenkamp:
We have reviewed the application from River Bend Station, Unit 1 (RBS) dated May 14, 2002, as supplemented by letters dated July 9, August 2, September 16, and November 7 and 22, 2002. The proposed amendment would increase the licensed power level by approximately 1.7 percent from 3,039 megawatts thermal (MWt) to 3,091 MWt. These changes would result from increased feedwater flow measurement accuracy to be achieved by utilizing high accuracy ultrasonic flow measurement instrumentation.
Enclosed is a draft safety evaluation (SE) for RBS. This draft SE is being withheld from public disclosure at this time because it may contain proprietary information.
We are providing this draft SE for the purpose of identifying if it contains any proprietary information pursuant to Section 2.790 of Title 10 of the Code of Federal Regulations. Please provide any comments that you may have on the enclosed draft SE with regard to the inclusion of proprietary information by January 17, 2003. Should a situation occur that prevents you from meeting that date, please contact Michael Webb of my staff at (301) 415-1347.
Sincerely,
/RA/
Robert A. Gramm, Chief, Section 1 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-458
Enclosure:
Draft Safety Evaluation cc w/o encl: See next page
ML030090478 OFFICE PDIV-1/PM PDIV-1/LA PDIV-1/SC NAME MWebb:db DJohnson RGramm DATE 1/6/2003 1/6/03 1/6/03
River Bend Station cc:
Winston & Strawn 1400 L Street, N.W.
Washington, DC 20005-3502 Manager - Licensing Entergy Operations, Inc.
River Bend Station P. O. Box 220 St. Francisville, LA 70775 Senior Resident Inspector P. O. Box 1050 St. Francisville, LA 70775 President of West Feliciana Police Jury P. O. Box 1921 St. Francisville, LA 70775 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76011 Ms. H. Anne Plettinger 3456 Villa Rose Drive Baton Rouge, LA 70806 Mr. Michael E. Henry, Administrator and State Liaison Officer Department of Environmental Quality P. O. Box 82135 Baton Rouge, LA 70884-2135 Wise, Carter, Child & Caraway P. O. Box 651 Jackson, MS 39205 Executive Vice President and Chief Operating Officer Entergy Operations, Inc.
P. O. Box 31995 Jackson, MS 39286-1995 General Manager - Plant Operations Entergy Operations, Inc.
River Bend Station P. O. Box 220 St. Francisville, LA 70775 Director - Nuclear Safety Entergy Operations, Inc.
River Bend Station P. O. Box 220 St. Francisville, LA 70775 Vice President - Operations Support Entergy Operations, Inc.
P. O. Box 31995 Jackson, MS 39286-1995 Attorney General State of Louisiana P. O. Box 94095 Baton Rouge, LA 70804-9095 Brian Almon Public Utility Commission William B. Travis Building P.O. Box 13326 1701 North Congress Avenue Austin, Texas 78701-3326