STATION:
SYSTEM:
TASK:
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM Rod Control (001)
Respond to a dropped rod with the reactor critical <POAH TASK NUMBER:
JPM NUMBER:
1140330401 2002 NRC COMMON S1 ALTERNATE PATH:
APPLICABILITY:
EOW ROW-K/A NUMBER:
IMPORTANCE FACTOR:
APE 003 AA1.03 3.6 RO 3.3 SRO EVALUATION SETTINGIMETHOD:
Simulator/Perform
REFERENCES:
$2.OP-IO.ZZ-0003, Rev. 16 S2.OP-AB.ROD-0002, Rev. 5 TOOLS AND EQUIPMENT:
VALIDATED JPM COMPLETION TIME:
13 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
D AINIMI*NIT REPRESENTAIE TRAINING SUPERVISOR or designee C1/--RO NS MA AGER or design e CAUTION:
A No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE:
ISAT D UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
eVA01----
Rev. 0 Nuclear Common Page 1 of 5
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
Rod Control (001)
Respond to a dropped rod with the reactor critical <POAH.
TASK NUMBER:
1140330401 INITIAL CONDITIONS:
The reactor is critical below P-6.
SIMULATOR SETUP:
- 2. MALF - Drop any single control bank rod shortly after the manual block of the Source Range NIS.
- 3. Mark up a copy of S2.OP-IO.ZZ-0003. Cross out all Precautions and Limitations that do NOT apply directly to the JPM task.
INITIATING CUE:
You have been assigned to complete a startup in accordance with S2.OP-IO.ZZ 0003. Assume all INITIAL CONDITIONS have been met and a proper watch relief has occurred. For the sake of expediting the JPM, only those PRECAUTIONS AND LIMITATIONS applying to the task-at-hand will be reviewed. Beginning at step 5.3.17 (CONTINUE with reactor power ascension.... ), continue the startup and level off at 1OE-8 amps at step 5.3.20.
Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Rev. 0 Nuclear Common SYSTEM:
TASK:
Page 2 of 5
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
ROD Control (001)
TASK:
Respond to a dropped rod with the reactor critical <POAH STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for NO.____
(#Denotes a Sequential Step)
STANDARD_
S/U UNSAT evaluation)
START TIME:
Provide a marked up copy of S2.OP-IO.ZZ-0003.
NOTE: Category I procedure use requirements apply.
5.3.17 CONTINUE with reactor power Withdraws Bank D rods to establish a ascension, with positive stable SUR not SUR < 1.0 DPM.
to exceed 1.0 DPM, by adjusting Control Bank D as needed.
5.3.18 OBSERVE source range and Monitors all channels of SR/IR NIS.
intermediate range levels on NIS for one decade overlap during performance of next step.
5.3.19 When P-6 (SR Permissive) green light is energized, as indicated on 2RP4:
A. SELECT one pen of NR-45 to an IR One pen selected to IR the other to a PR.
and the other pen to a PR channel.
B. BLOCK SR High Flux Trip by Depresses both trains of pushbuttons.
depressing both "BLOCK SOURCE RANGE A" AND "BLOCK SOURCE RANGE B" pushbuttons on console.
C. ENSURE SR Trains A&B TRIP Both trains blocked BLOCKED blue light is illuminated on 2RP4 AND OHA E-5, SR DET VOLT TRBL alarms.
2 Insert RT-1, Dropped rod in Control Bank "D"
Rev. 0 Page 3 of 5 Nuclear Common
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NC.TQ-WB.ZZ-031 0(Z)
NAME:
DATE:
SYSTEM:
ROD Control (001)
TASK:
Respond to a dropped rod with the reactor critical <POAH STEP COMMENTS STEP
(*Denotes a Critical Step)
EVAL (Required for NO.
(#Denotes a Sequential Step)
STANDARDS UNSAT evaluation) 3 Responds to OHA alarms for dropped rod Enters S2.OP-AB.ROD-0002.
and/or RPI.
3.1 PLACE the Rod Bank Selector Switch to Verifies switch in MANUAL.
MANUAL.
3,2 STABILIZE plant conditions as follows:
A. Stop any turbine load change.
No turbine load change or boron change in progress.
B. Stop any boron change in progress.
3.3 Adjust TAVG to within 1.5°F - - -
No action - reactor is < POAH.
3.4 Is the Reactor subcritical as a result of Answers YES.
the dropped rod?
3.5 Fully INSERT ALL Control and Shutdown Using MANUAL on Rod Bank Selector Banks.
Switch, begins inserting the Control Banks.
NOTE: Terminate the JPM after action to insert rods is initiated.
STOP TIME:
Terminating Cue: Acknowledge operator action and then state "this JPM is complete".
Nuclear Common Rev. 0 Page 4 of 5
NC.TQ-WB.ZZ-0310(Z)
INITIAL CONDITIONS:
The reactor is critical below P-6.
INITIATING CUE:
You have been assigned to complete the startup in accordance with S2.OP-IO.ZZ 0003. Assume all INITIAL CONDITIONS have been met and a proper watch relief has occurred. For the sake of expediting the JPM, only those PRECAUTIONS AND LIMITATIONS applying to the task-at-hand will be reviewed. Beginning at step 5.3.17 (CONTINUE with reactor power ascension.... ), continue the startup and level off at 1 OE-8 amps at step 5.3.20.
Nuclear Common Page 5 of 5
NC.TQ-WB.ZZ-031 0(Z)
STATION:
SYSTEM:
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM ECCS TASK:
TASK NUMBER:
JPM NUMBER:
Align for CL recirculation with 21 SJ44 AUTO ARMED failed lAW 2-EOP-LOCA-3 1150100501 2002 GOLF NRC RO S2 ALTERNATE PATH: W APPLICABILITY:
EO --
RO W
K/A NUMBER:
IMPORTANCE FACTOR:
STA EPE 011 EA1.11 4.2 RO 4.2 SRO SRO [X EVALUATION SETTING/METHOD:
Simulator/Perform
REFERENCES:
2-EOP-LOCA-3, Revision 22 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
14 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
BARMINING NIT REPRESENTA IVE TRAINING SUPERVISOR or designee "OPERATIONS lANAGER or designee CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: 11 SAT R UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
zlvldjý4--
Page 1 of 5 Rev. 0 Nuclear Common
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRA JOB PERFORMANCE MEASURE NAME:
DATE:
ECCS Align for CL Recirculation with 21SJ44 AUTO ARMED failed lAW 2 EOP-LOCA-3 TASK NUMBER:
1150100501 INITIAL CONDITIONS:
- 2. All vital buses are energized.
- 3. The Crew has just transitioned to LOCA-3.
SIMULATOR SETUP:
- 1.
Reset to IC-191.
- 2.
Perform EOP's until transition to LOCA-3.
INITIATING CUE:
Perform the steps of LOCA-3.
Nuclear Common SYSTEM:
TASK:
Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Page 2 of 5 Rev. 0
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
SYSTEM:
ECCS TASK:
Align for CL Recirculation with 21SJ44 AUTO ARMED failed lAW 2-EOP-LOCA-3 STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
Provide "Tear Off Sheet" to Candidate.
START TIME:
1 Do not implement any FRP's until Reads CAUTION directed by this EOP.
2 Is Containment Recirc Sump level Checks level and answers YES.
>62%?
3 Depress SUMP AUTO ARMED Depresses correct pushbuttons.
pushbuttons on 21 and 22SJ44 bezels.
4 Remove lockouts from the following:
Selects VALVE OPERABLE at RP-4:
"* 2SJ67 SI Pp Miniflow e SJ67 SI Pp Miniflow
"* 2SJ68 SI Pp Miniflow SJ68 SI Pp Miniflow
"* 2SJ69 Common Suction SJ69 Common Suction 5
Are 21 and 22 SJ44 open?
Answers NO, 21SJ44 is closed.
5.1 Reset SI.
Verifies SI RESET, both trains.
Reset EACH SEC.
Verifies all SECs RESET.
5.2 Is 21SJ44 Open.
NO.
Stop 21 RHR Pump.
21 RHR Pump stopped.
Close 2SJ69.
2SJ69 closed.
Start 22 RHR Pump.
Verifies 22 RHR Pump running.
Nuclear Common Page 3 of 5 Rev. 0
SYSTEM:
- TAI, OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE ECCS Alian for CL Recirculation with 21SJ44 AUTO ARMED failed lAW 2-EOP-LOCA-3 NC.TQ-WB.ZZ-031 0(Z)
NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
- ____O._
(#Denotes a Sequential Step)
STANDARD_
SIU UNSAT evaluation)
Initiate CLOSE on 21RH4 and continue.
21RH4 CLOSE initiated.
13 Initiate OPEN on 21SJ44 and continue.
21SJ44 OPEN initiated.
5.4 When 21SJ44 opens then start 21 RHR 21 RHR pump running with 21SJ44 OPEN pump.
indication STOP TIME:
Terminating Cue: When 21 RHR pump is running with 21SJ44 OPEN then state "This JPM is complete".
Nuclear Common Rev. 0 Page 4 of 5
NC.TQ-WB.ZZ-031 0(Z)
INITIAL CONDITIONS:
- 2. All vital buses are energized.
- 3. The Crew has just transitioned to LOCA-3.
INITIATING CUE:
Perform the steps of LOCA-3.
Nuclear Common Page 5 of 5
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM STATION:
SYSTEM:
PZR Pressure TASK:
TASK NUMBER:
JPM NUMBER:
ALTERNATE PATH: [
APPLICABILITY:
EO W
Re-energize Pressurizer Heaters in accordance with 2-EOP TRIP-2 1150360501 2002 GOLF NRC RO S3 iK/A NUMBER:
EPE 007 EA1.03 IMPORTANCE FACTOR:
4 -.-
4,1 RO SRO ROW STA SRO EVALUATION SETTING/METHOD:
Simulator/Perform
REFERENCES:
2-EOP-TRIP-2, Rev. 24 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
5 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
GAIN NIT RRG GAIENT IT REPRESENTA IVE y/2fl TRAINING SUPERVISOR or designee O1PERATIONS M/NAGER or designee CAUTION:
No Ilant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: F SAT R UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Page 1 of 4 Rev. 0 Nuclear Common
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
TASK:
PZR Pressure Re-energize Pressurizer Heaters in accordance with 2-EOP-TRIP-2 TASK NUMBER:
1150030501 INITIAL CONDITIONS:
A manual reactor trip was initiated due to a main turbine bearing oil pump failure.
SIMULATOR SETUP:
- 1. Reset to IC-183 INITIATING CUE:
The control room crew has completed TRIP-2 through Step 12, directing them to Step 15 (PZR Heater Power Availability). Beginning at Step 15, perform 2-EOP-TRIP-2.
Rev. 0 Nuclear Common Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Page 2 of 4
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
TASK:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
SIU UNSAT evaluation)
START TIME:
15 Is 2E Group Bus energized and 2E6D Checks status of 2E6D and answers NO.
closed?
Is 2G Group Bus energized and 2G6D Checks status of 2G6D and answers NO.
closed?
Send Operators to open the Rod Drive CUE:
CRS has already dispatched a MG set motor breakers.
NEO.
Simulator Operator: Insert RT-1 Are Rod Drive MG set breakers open?
CUE:
Simulator Operator reports back as (NEO) that Rod Drive MG Set motor breakers are open.
15.1 Close 2E6D and 2G6D closed.
Closes 2E6D and 2G6D.
Is 2E Group Bus energized and 2E6D Answers YES closed?
STOP TIME:
Terminating Cue: Acknowledge 2E Group Bus energized and 2E6D closed and state "this JPM is complete".
Nuclear Common Rev. 0 Page 3 of 4
NC.TQ-WB.ZZ-0310(Z)
INITIAL CONDITIONS:
A manual reactor trip was initiated due to a main turbine bearing oil pump failure.
INITIATING CUE:
The control room crew has completed 2-EOP-TRIP-2 through Step 12, directing them to Step 15 (PZR Heater Power Availability). Beginning at Step 15, perform 2-EOP TRIP-2.
Nuclear Common Page 4 of 4
STATION:
SYSTEM:
TASK:
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM AFW (061)
Initiate AFW flow/AF21 Pressure Override TASK NUMBER:
JPM NUMBER:
0610020101 2002 GOLF NRC RO/SRO S4 ALTERNATE PATH:
APPLICABILITY:
EO W
RO K/A NUMBER:
IMPORTANCE FACTOR:
STA =
061 A2.05 3.1 3.4 RO SRO SRO EVALUATION SETTING/METHOD:
Simulator/Perform
REFERENCES:
EOP-TRIP-2, Rev. 24 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
5 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
B
!AR*GAININ UNIT REPRESENTfTIVE A4
NJZ
-TRAINING SUPtRVISOR or designee AS
ýNAGER or designee CAUTION:
J No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: F SAT D UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Page 1 of 8 "Oz, Rev. 0 Nuclear Common
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
Initiate AFW flow/AF21 Pressure Override TASK NUMBER:
0610020101 / 1150020501 INITIAL CONDITIONS:
- 1.
A manual reactor trip was initiated due to the simultaneous loss of both SGFP's.
- 2.
The Crew has just transitioned to 2-EOP-TRIP-2.
SIMULATOR SETUP:
Reset to IC-184 INITIATING CUE:
You are the Control Board Operator. Starting at Step 1, execute the steps of 2 EOP-TRIP-2.
Rev. 0 Nuclear Common SYSTEM:
AFW TASK:
Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Page 2 of 8
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
AFW Initiate AFW flow/AF21 Pressure Override "1Q, W 0 In ti t
errid STEP rll~
- kI""I STEP
(*Denotes a Critical Step)
(#Denotes a Sequential Step)
START TIMEF STANDARD i
I EVAL S/U U,,UIVII lrml* I a+
(Required for UNSAT evaluation)
Announce twice on Station PA "Unit 2 Makes announcement.
2 Implement the Event Classification CUE: Event Classification Guide.is being Guide.
implemented.
3 Is total AFW >22E41bm/hr?
Answers NO.
Start 21-23 AFW Pumps.
Determines that 21 and 22 AFW Pumps are running and 23 AFW Pump is tripped.
"* Open 21-24AF21 Presses open on 21-24AF21 and notes that they did not open. Should note that
"* Open 21-24AF11 AFW Pump discharge pressure is above the opening interlock setpoint.
Verifies AF11 s open.
Rev. 0 Nuclear Common
I(.
TA
-- I
-!I STEP NO.
I I
NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
Page 3 of 8
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
SYSTEM:
AFW Initiate AFW flow/AF21 Pressure Override Nuclear Common TA5RK:
STEP COMMENTS STEP
(*Denotes a Critical Step)
EVAL (Required for
- __NO._
(#Denotes a Sequential Step)
STANDARD S/U UNSAT evaluation)
Depress PRESSURE OVERRIDE PRESSURE OVERRIDE DEFEAT This Step is Critical if DEFEAT.
depressed. It is acceptable to estabish FRHS-1 is NOT valve demand before depressing entered.
PRESSURE OVERRIDE DEFEAT.
Operates AF21's to establish AFW flow to greater than 22E41bm/hr NOTE: This is not a specific procedural step in 2-EOP-TRIP-2 but is a step in other procedures. Operators are expected to take compensatory action for failures. It is acceptable to transition to FRHS-1 in order to initiate AFW flow. If Candidate implements FRHS-1 go to next page. If Candidate attempts to continue in EOP TRIP-2 then Cue CUE: CRS has implemented 2-FRHS-1 due to Red Path for HS Rev. 0 Page 4 of 8
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
AFW Initiaite AFW flnw/AF29 Press~ure Override NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
- _NO.
(#Denotes a Sequential Step)
SSU UNSAT evaluation)
Is AFW Flow >22E41bm/hr?
Answers YES.
JPM complete at this point if FRHS is not implemented.
IF 2-EOP-FRHS-1 IS IMPLEMENTED:
1 IS TOTAL AFW <22E4LBM/HR DUE TO Answers NO OPERATOR ACTIONS?
2 IF AT LEAST ONE INTACT OR Acknowledges Step. Determines no RUPTURED SG IS AVAILABLE THEN FAULTED SG DO NOT FEED A FAULTED SG 3
IS RCS PRESSURE GREATER THAN Answers YES ANY INTACT OR RUPTURED SG PRESSURE?
3.1 ARE RCS T-HOTS GREATER THAN Answers YES 350' 4
IF WR LEVELS IN AT LEAST THREE SG'S ARE LESS THAN 32% (36%
ADVERSE) THEN IMMEDIATELY STOP ALL RCP'S AND GO TO STEP 23 TO INTITIATE RCS FEED AND BLEED 5
IF RCS PRESSURE IS 2335 PSIG OR Determines RCS pressure is less than GREATER DUE TO LOSS OF 2335 psig.
SECONDARY HEAT SINK THEN IMMEDIATELY STOP ALL RCP'S AND GO TO STEP 23 TO INTITIATE RCS FEED AND BLEED Rev. 0 Nuclear Common TA *V.'
Page 5 of 8
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
AFW I A %) :
III IL I L
- 1 V
u J vv
, u u
v STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
- _NO.
(#Denotes a Sequential Step)
S/U UNSAT evaluation) 6 IF 'AFWST LEVEL LO-LO' ALARM Acknowledges Step. Determines the alarm ACTUATES (10.3%) THEN SHIFT AFW is not actuated.
PUMP SUCTION TO AN ALTERNATE SOURCE 7
IS 21 OR 22 CHARGING PUMP Answers YES AVAILABLE 8
CLOSE THE FOLLOWING VALVES:
21 THROUGH 24GB4 (SG CLOSES 21 THROUGH 24GB4 OUTLET) 21 THROUGH 24SS94 (SG BID SAMPLING)
CLOSES 21 THROUGH 24SS94 8.1 START AT LEAST ONE AFW PUMP Determines 21 and 22 AFW Pumps are running IS AT LEAST ONE AFW PUMP Answers YES RUNNING OPEN INTACT OR RUPTURED AF1 1 Attempts to open AF21 valves AND AF21 (SG INLET VALVES)
ARE AF21 VALVES OPEN ON INTACT Answers NO OR RUPTURED SG'S FOR EACH AF21 NOT OPENED FO EAC AF2 NOT_________OPENED___________
Rev. 0 Nuclear Common
- A IP* lJ I
Page 6 of 8
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
SYSTEM:
TAK*K AFW Initiate AFW flow/AF21 Pressure Override STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
- __O.
(#Denotes a Sequential Step)
SIU UNSAT evaluation)
- SET AF21 VALVE DEMAND TO Sets all AF21 demands to 95%
95%
DEPRESS 'PRESSURE OVERRIDE DEFEAT' Depresses defeat pushbuttons PUSHBUTTONS ARE INTACT OR RUPTURED AF1 1 Answers YES AND AF21 VALVES OPEN?
IS TOTAL AFW FLOW GREATER THAN Answers YES 22E4 LBM/HR?
STOP TIME:
Terminating Cue: Reports AFW Flow >22E41bm/hr. State "this JPM is complete".
Rev. 0 Nuclear Common Page 7 of 8
NC.TQ-WB.ZZ-031 0(Z)
INITIAL CONDITIONS:
- 1.
2.
A manual reactor trip was initiated due to the simultaneous loss of both SGFP's.
The Crew has just transitioned to 2-EOP-TRIP-2.
INITIATING CUE:
You are the Control Board Operator. Starting at Step 1, execute the steps of 2-EOP TRIP-2.
Nuclear Common Page 8 of 8
STATION:
SYSTEM:
TASK:
TASK NUMBER:
JPM NUMBER:
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM Containment Spray (026)
Containment Spray Failure During LBLOCA 1150360501 2002 GOLF NRC RO/SRO 85 ALTERNATE PATH:
KIA NUMBER:
E IMPORTANCE FACTOR:
3.7 APPLICABILITY
SRO L-EVALUATION SETTING/METHOD:
Simulator/Perform
REFERENCES:
2-EOP-FRCE-1, Rev. 21 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
5 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
A
^
E14 EA1.1 3.7 SRO REPRESENTAIVE or designee or designee ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: E] SAT r UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
Rev. 0 Nuclear Common Page 1 of 5
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
TASK:
Containment Spray (026)
Containment Spray failure during LBLOCA TASK NUMBER:
1150360501 INITIAL CONDITIONS:
- 1. A rapidly progressing LOCA occurred after a reactor trip.
- 2.
AUTO SI has actuated.
- 3.
The CRS has transitioned to 2-EOP-FRCE-1, from 2-EOP-LOCA-1.
SIMULATOR SETUP:
- 1. Reset to IC-188
- 2. FRCE-1 Attachment 1 Phase A valve alignment filled out.
INITIATING CUE:
You are the Control Board Operator. Perform the steps of 2-EOP-FRCE-1.
Nuclear Common Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Rev. 0 Page 2 of 5
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
Containment Spray (026)
TASK:
Containment Spray failure during LBLOCA STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
START TIME:
1 Close Phase A Isolation Valves not CUE: Provide filled out copy of FRCE-1 needed for plant recovery...
2 Close the following valves:
"* 2VC1 and 2VC2
"* 2VC3 and 2VC4 Verifies 2VC1 - 6 closed.
"* 2VC5 and 2VC6 3
Has Containment Pressure remained Checks and answers NO.
less than 15 psig?
3.1 Is EOP-LOCA-5 in effect?
Answers NO or CUE: NO 3.2 Start both CS Pumps.
Starts both CS Pumps.
3.3 Open 21 and 22CS2 (CS Pump Opens 21CS2 and 22CS2.
Discharge Valves).
Open 2CS14, 2CS16, 2CS17 (Tank Opens 2CS14, 2CS16, 2CS17.
Discharge Valves).
3.4 Close Phase B Isolation Valves.
From Table B closes at least:
"* 2CCl17or118
"* 2CC131 or 190
"* 2CC136or187 Nuclear Common Page 3 of 5 Rev. 0
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
TASK:
Containment Spray (026)
Containment Spray failure during LBLOCA NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
SIU UNSAT evaluation) 3.5 Stop ALL RCPs.
Verifies all RCP's stopped.
STOP TIME:
Terminating Cue: Acknowledge RCP's stopped and state "this JPM is complete".
Nuclear Common Page 4 of 5 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
INITIAL CONDITIONS:
A rapidly progressing LOCA occurred after a reactor trip.
AUTO SI has actuated.
The CRS has transitioned to 2-EOP-FRCE-1, from 2-EOP-LOCA-1.
INITIATING CUE:
You are the Control Board Operator. Perform the steps of 2-EOP-FRCE-1.
Nuclear Common
- 1.
- 2.
3.
Page 5 of 5
STATION:
SYSTEM:
TASK:
TASK NUMBER:
JPM NUMBER:
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM AC Electrical (062)
Energize a 4KV Vital Bus from a Station Power Transformer (SPT) in accordance with 2-EOP-LOPA-1.
1150140501 2002 GOLF NRC RO S6 ALTERNATE PATH:
APPLICABILITY:
EOW K/A NUMBER:
IMPORTANCE FACTOR:
RO STA EPE 055 EA1.07 4.3 RO 4.5 SRO SRO L-X-EVALUATION SETTING/METHOD:
Simulator/Perform
REFERENCES:
S2.OP-SO.DG-0001, Rev. 26; S2.OP-SO.4KV-0001, Rev. 23 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
13 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
BA RRNING UNI REPRESENTATIV TRoAINING SUPRVISOR or designee OPERTINS MAdsg AGER or designee CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE:
SAT UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Nuclear Common Page 1 of 7 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
AC Electrical (062)
TASK:
Energize a 4KV Vital Bus from a Station Power Transformer (SPT) lAW LOPA-1.
TASK NUMBER:
1150140501 INITIAL CONDITIONS:
- 1.
Unit 2 experienced a loss of all AC Power.
- 2.
2A EDG is providing power to 2A Vital Bus and the following running equipment: 21 CCW Pump, 21 SW Pump, 21 CFCU (LOW), 21 SWGR Room Supply Fan, 21 SWGR Room Exhaust Fan.
- 3.
2B EDG was just started. 24 SW Pump is running.
- 4.
24 Station Power Transformer (SPT) has just been energized.
- 5.
The CRS has specified that S2.OP-SO.DG-0001 Section 5.8 and S2.OP-SO.4KV-0001 Section 5.3.4 will be utilized to energize 2A Vital Bus from 24 SPT.
SIMULATOR SETUP:
Reset to IC-186 Sign off all procedure Prerequisites and Precautions and Limitations that do NOT apply directly to the task.
INITIATING CUE:
You are the Control Board Operator. Complete Section 5.8 of S2.OP-SO.DG-0001, and then utilize Section 5.3.4 of S2.OP-SO.4KV-0001 to restore power to 2A Vital Bus from 24 SPT. For the purpose of expediting the JPM, all procedure Prerequisites and Precautions and Limitations that do NOT apply directly to the task have been signed off.
Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Nuclear Common Rev. 0 Page 2 of 7
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
AC Electrical (062)
TASK:
Energize a 4KV Vital Bus from a Station Power Transformer (SPT) lAW STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
SIU UNSAT evaluation)
START TIME:
Provide marked up copies of S2.OP SO.DG-0001 and S2.OP-SO.4KV-0001.
1 S2.OP-SO.DG-0001, Section 5.8 5.8.1 If 2A Diesel Generator is paralleled on 2A Marks step N/A.
4KV Vital Bus ----
Nuclear Common Page 3 of 7 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE AC Electrical (062)
Eneraize a 4KV Vital Bus from a Station Power Transformer (SPT) lAW STEP STEP NO.
(*Denotes a Critical Step)
STANDARD
(#Denotes a Sequential Step) 5.8.2 IF 2A Vital Bus is isolated and energized from 2A Diesel Generator, THEN:
A. PLACE redundant equipment in service as necessary to support de energizing 2A Vital Bus.
One-by-one, provide the following CUES:
"* Start 21 Charging Pump*
"* Start 22 CCW Pump*
"* Start 22 CFCU in LOW
"* Start 22 CFCU in LOW
"* Start 22 SWGR Room Supply Fan
"* Start 22 SWGR Room Exhaust Fan STARTS each piece of equipment.
NAME:
DATE:
I I
t I
B. STOP all 2A Vital Bus loads using.
One-by-one, provide the following CUES:
"* Stop 21 CCW Pump*
"* Stop 21 SW Pump*
"* Stop 21 CFCU in LOW*
"* Stop 21 SWGR Room Supply Fan*
Stop 21 SWGR Room Exhaust Fan*
STOPS each piece of equipment.
Rev. 0 Nuclear Common SYSTEM:
(Required for UNSAT evaluation)
I I
I Page 4 of 7
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
AC Electrical (062)
E~nerize. a 4KV Vital Bus from a Station Power Transformer (SPT) lAW NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
- _NO_
(#Denotes a Sequential Step)
S/U UNSAT evaluation) 5.8.3 OPEN 2A DIESEL GENERATOR Should open breaker from Control Console BREAKER BY PERFORMING ONE OF THE FOLLOWING:
B. Press 2A BREAKER OPEN Opens 2A EDG Breaker from 2CC3.
pushbutton. (2CC3) 5.8.4 ALLOW diesel to run unloaded for >3 Marks the time.
minutes prior to stopping.
If necessary provide:
CUE: Perform S2.OP-SO.4KV, Section 5.3.4 while 2A EDG continues to run.
2 S2.OP-SO.4KV, Section 5.3.4 5.3.4 IF 2A 4KV Vital Bus is to be energized from 24 SPT, THEN:
A. Direct NEO to rack up Pages NEO.
2AD1AX24ASD, 24 SPT INFEED BREAKER.
CUE: 2AD1AX24ASD, 24 SPT INFEED BREAKER is racked up.
7 B. PRESS Mimic Bus 2A VITAL BUS Presses Mimic Bus 2A VITAL BUS INFEED 24ASD BREAKER INFEED 24ASD BREAKER pushbutton pushbutton and ensure console bezel and verifies 24 ASD MIMIC BUS INTLK 24 ASD MIMIC BUS INTLK CLOSE CLOSE selection illuminated.
selection illuminates.
Rev. 0 Nuclear Common TAV*
Page 5 of 7
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
AC Electrical (062)
TASK:
Energize a 4KV Vital Bus from a Station Power Transformer (SPT) lAW STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
- _NO.
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
C. PERFORM the following:
- 1. PRESS AND HOLD control console 24ASD CLOSE pushbutton.
- 2. RELEASE pushbutton when 24 ASD Presses 24 ASD CLOSE pushbutton and indicates closed, releases when breaker indicates closed.
- 3. ENSURE the following:
Verifies:
- a. Console bezel 24 ASD MIMIC o Console bezel 24 ASD MIMIC BUS BUS INTLK CLOSE selection INTLK CLOSE selection extinguished.
extinguished.
- b. 2A 4KV Vital Bus voltage is 0
2A 4KV Vital Bus voltage is 4.22-4.36KV 4.22-4.36KV
- c. OHAJ-17, 2A4KVVTL BUS OHAJ-17, 2A4KVVTL BUS UNDRVOLT is clear.
UNDRVOLT is clear.
D. Complete Attachment 3.
See Terminating Cue STOP TIME:
Terminating Cue: At Step D to complete Attachment 3, state "this JPM is complete".
Rev. 0 Nuclear Common Page 6 of 7
NC.TQ-WB.ZZ-031 0(Z)
INITIAL CONDITIONS:
- 1.
Unit 2 experienced a loss of all AC Power.
- 2.
2A EDG is providing power to 2A Vital Bus and the following running equipment:
21 CCW Pump, 21 SW Pump, 21 CFCU (LOW), 21 SWGR Room Supply Fan, 21 SWGR Room Exhaust Fan.
- 3.
2B EDG was just started. 24 SW Pump is running.
- 4.
24 Station Power Transformer (SPT) has just been energized.
- 5.
The CRS has specified that S2.OP-SO.DG-0001 Section 5.8 and S2.OP-SO.4KV-0001 Section 5.3.4 will be utilized to energize 2A Vital Bus from 24 SPT.
INITIATING CUE:
You are the Control Board Operator. Complete Section 5.8 of S2.OP-SO.DG-0001, and then utilize Section 5.3.4 of S2.OP-SO.4KV-0001 to restore power to 2A Vital Bus from 24 SPT. All procedure Prerequisites and Precautions and Limitations that do NOT apply directly to the task have been signed off Nuclear Common Page 7 of 7
STATION:
SYSTEM:
TASK:
TASK NUMBER:
JPM NUMBER:
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM Component Cooling Water Split the Component Cooling Water Headers in accordance with 2-EOP-LOCA-3 1150040501 2002 GOLF NRC RO S7 ALTERNATE PATH: r APPLICABILITY:
EO =
ROW-K/A NUMBER:
IMPORTANCE FACTOR:
STA =--
008 A4.01 3.3 RO 3.1 SRO SROFl EVALUATION SETTING/METHOD:
Simulator/Perform
REFERENCES:
2-EOP-LOCA-3, Rev.22 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
8 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
'3 ARGATNINr3 UNIT REPRESEN)ATIVE CAUTION:
TRAINING SOR or designee OPMANAGER No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE:
SAT UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Nuclear Common Page I of 4 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRA JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
TASK:
Component Cooling Water Split the CCW Headers TASK NUMBER:
1150040501 INITIAL CONDITIONS:
- 1.
The operating Crew is responding to a LOCA.
- 2.
2-EOP-LOCA-3 has been initiated and is complete through Step 22, 21 & 22 CCW HX SW ALIGNMENT.
SIMULATOR SETUP:
- 1.
Reset to IC-187.
- 3.
Complete EOP-LOCA-3 to Step 23, 21 & 22 CCW HX SW ALIGNMENT.
INITIATING CUE:
Perform 2-EOP-LOCA-3, beginning at Step 23.
Nuclear Common Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Page 2 of 4 Rev. 0
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
Emergency Response TASK:
Perform the actions for SI Termination (Split CCW Headers)
NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
START TIME:
23 Is SW available to BOTH CCW Hxs?
Checks SW PumpNalve alignment and answers YES.
24 Are at least two CCW Pumps running?
Verifies 22 and 23 CCW Pumps running.
Is 21 CCW Pump running?
Answers NO.
OPEN the following valves:
- 2CC17, CCW Pump Suction Verifies 2CC17 OPEN.
Crossover.
- 21CC3, Pump Outlet X-Conn Verifies 21CC3 OPEN.
CLOSE the following valves:
2CC18, CCW Pump suction Presses the CLOSE pushbutton for 2CC18 crossover and verifies indication.
22CC3, Pump outlet X-Conn Presses the CLOSE pushbutton for 22CC3 and verifies indication.
e 2CC31, 22 CC Hx out to Aux HDR Presses the CLOSE pushbutton for 2CC31 and verifies indication.
STOP TIME:
Terminating Cue: Reads step "RETURN TO PROCEDURE IN EFFECT".
Nuclear Common Page 3 of 4 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
INITIAL CONDITIONS:
The operating Crew is responding to a LOCA.
2-EOP-LOCA-3 has been initiated and is complete through Step 22, 21 & 22 CCW HX SW ALIGNMENT.
INITIATING CUE:
Perform 2-EOP-LOCA-3, beginning at Step 23.
Nuclear Common
- 1.
2.
Page 4 of 4
NC.TQ-WB.ZZ-031 0(Z)
STATION:
SYSTEM:
TASK:
TASK NUMBER:
JPM NUMBER:
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM Pressurizer Place POPS in service 0100060101 2002 GOLF NRC SROI S3/SROU S1 ALTERNATE PATH: LJ K/A NUMBER:
(
IMPORTANCE FACTOR:
4.0 APPLICABILITY
RO EOW ROLE STALZ SROfl EVALUATION SETTING/METHOD:
Simulator/Perform
REFERENCES:
S2.OP-SO.PZR-0004, Rev. 11 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
10 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A
)10 A4.03 3.8 SRO APPROVAL:
ICGAININq UNIT REPRESENT TIVE
,1 TRAINING SUPERVISOR or designee OPERAT[ONS MYNAGER or desigrnee ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: F SAT R UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Nuclar CmmonPag 1 o 6 Rv.
CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
Rev. 0 Nuclear Common Page 1 of 6
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
TASK:
Pressurizer Place POPS in service TASK NUMBER:
0100060101 INITIAL CONDITIONS:
Unit 2 is in HSD.
Provide Candidate copy of marked up S2.OP-SO.PZR-0004 SIMULATOR SETUP:
Reset to IC-181 INITIATING CUE:
Place Channel I and II of POPS in service in accordance with S2.OP-SO.PZR 0004.
Rev. 0 Nuclear Common Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Page 2 of 6
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
Pressurizer Place POPS in service NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
START TIME:
1 Evaluator should provide a properly marked up copy of S2.OP-SO.PZR-0004.
Candidate reviews procedure.
NOTE: Category II procedure use requirements apply.
5.1.1 Ensure 2PC405C-D, 2 REACT POPS NOT SIMULATED CHAN I PRESS PROT SIGNAL COMPARATOR, #1 OUT not energized CUE:
Fuse light is extinguished.
(fuse light extinguished).
5.1.2 Ensure 2PR6 STOP VALVE OPEN.
Verifies 2PR6 OPEN.
5.1.3 Insert key in POPS Channel I ON/OFF Inserts key in Ch. I.
Key Slot.
5.1.4 Rotate Channel I Key Switch Rotates key CLOCKWISE and obtains red CLOCKWISE.
ON indicating light.
5.1.5 Ensure Channel I ON red indicating light Verifies red light is illuminated.
illuminates.
5.1.6 Rotate Channel I Key Switch Returns key to original position.
COUNTERCLOCKWISE.
5.1.7 REMOVE key from the POPS Channel I Removes key.
ON/OFF key slot.
Nuclear Common TASK:
Page 3 of 6 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
Pressurizer TPSK:
Place POPS in service NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation) 5.1.8 Complete Att. 1, Section 1.0.
CUE:
Substitute self-check for Independent Verification.
Enters information on Att. 1 and corrects any operational errors.
5.1.9 If a PORV blocking device is installed...
CUE:
No PORV blocking device is installed.
5.1.10 If 2PR1 is open, then select 2PR1 to Verifies 2PR1 closed.
MANUAL/CLOSE 5.2.1 Ensure 2PC403C-D, 2 REACT POPS NOT SIMULATED CHAN I PRESS PROT SIGNAL COMPARATOR, #1 OUT not energized CUE:
Fuse light is extinguished.
(fuse light extinguished).
5.2.2 ENSURE 2PR7 STOP VALVE OPEN.
Verifies 2PR6 OPEN.
5.2.3 Insert key in POPS Channel II ON/OFF Inserts key in Ch. I1.
Key Slot.
5.2.4 ROTATE Channel II Key Switch Rotates key CLOCKWISE and obtains red CLOCKWISE.
ON indicating light.
5.2.5 ENSURE Channel II ON red indicting Verifies red light is illuminated.
light illuminates.
5.2.6 ROTATE Channel II Key Switch Returns key to original position.
COUNTERCLOCKWISE.
5.2.7 Nuclear Common REMOVE key from the POPS Channel II ON/OFF key slot.
Removes key.
Page 4 of 6 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
Pressurizer I
f1 I
l*3O
- , n
-.. ~,.-E,.-a NAME:
DATE:
I Abi\\:
Pldace rjr.
III "Sul VlDo STEP COMMENTS STEP
(*Denotes a Critical Step)
EVAL (Required for I
(#Denotes a Sequential Step)
STNDR S/U UNSAT evaluation) 5.2.8 Complete Att. 1, Section 2.0.
CUE:
Substitute self-check for Independent Verification.
Enters information on Att. 1 and corrects any operational errors.
5.2.9 If a PORV blocking device is installed...
CUE:
No PORV blocking device is installed.
5.2.10 If 2PR2 is open, then select 2PR2 to Verifies 2PR2 closed.
MANUAL/CLOSE.
STOP TIME:
Terminating Cue: Acknowledge report and state "this JPM is complete".
Rev. 0 Page 5 of 6 Nuclear Common
NC.TQ-WB.ZZ-0310(Z)
INITIAL CONDITIONS:
Unit 2 is in Hot Shutdown.
INITIATING CUE:
Place Channel I and II of POPS in service in accordance with S2.OP-SO.PZR-0004.
Nuclear Common Page 6 of 6
STATION:
SYSTEM:
TASK:
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM EDG (064)
Start and load an EDG from the Control Room lAW LOPA-1 TASK NUMBER:
JPM NUMBER:
1150140501 2002 GOLF NRC SRO S6 ALTERNATE PATH:
APPLICABILITY:
EO W
RO-K/A NUMBER:
IMPORTANCE FACTOR:
STA =
EPE 055 EA1.02 4.3 RO 4.4 SRO SRO EVALUATION SETTING/METHOD:
Simulator / Perform
REFERENCES:
2-EOP-LOPA-1, Rev.24 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
8 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
DARGAININ UNIT REPRESENTTIVE V TRAINING SUPERVISOR or designee X
- 3 (5-ERA(f"ONS M,$NAGER or designee CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE:
ISAT
[:] UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Nuclear Common m
Rev. 0 Page 1 of 5
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
TASK:
EDG (064)
Start and load an EDG from the Control Room in accordance with 2 EOP-LOPA-1 (ALTERNATE PATH)
TASK NUMBER:
1150140501 INITIAL CONDITIONS:
- 1.
The unit was at 100% power with 2B EDG in LOCKOUT for DUTR replacement.
- 2.
A loss of off-site power occurred and 2A and 2C EDG's failed to start.
- 3.
A NEO has de-energized all SEC's and Maintenance reports that 2B EDG can be started.
SIMULATOR SETUP:
- 1. Reset to IC-185
- 2. Perform the actions of 2-EOP-TRIP-1 and LOPA-1 through Step 11.
INITIATING CUE:
Beginning at Step 12, perform the actions of 2-EOP-LOPA-1.
Nuclear Common Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Rev. 0 Page 2 of 5
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
EDG TASK:
Start and load an EDG from the Control Room lAW LOPA-1 (SW Pp fails to start)
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
START TIME:
12 Depress bezel STOP pushbuttons for all Depresses STOP pushbutton for each of loads in Table A.
the following:
- 21/22/23/24/25/26 SW Pumps
- 21/22 SI Pumps
- 21/22/23/24/25 CFCUs (HI & LO Speed)
- 21/22 CS Pumps
- 21/22 Charging Pumps 13 CAUTION step for Diesel Loading limits Reviews Diesel Loading Limits 14 Restore power to de-energized 4KV vital buses:
- Start 2B DG Depresses 2B EDG START CLOSE 2B DG output breaker Observes that 2B EDG comes up to operating speed and voltage then:
- Depresses 2BDG Mimic Bus Interlock PB Nuclear Common Page 3 of 5 Rev. 0
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE EDG Start and load an EDG from the Control Room lAW LOPA-1 (SW Pp fails to start)
STEP
- Denotes a Critical Ste When any 4KV Vital Bus is energized then:
"* Start only one SW Pump on that bus
"* Close the associated Turbine Area SW Stop Valve.
STOP TIME:
1 STANDARD Depresses 2BDG Breaker CLOSE PB, energizing the bus Depresses START pushbutton for 23 or 24 SW Pump and recognizes pump fails to start.
" Attempts to start the other SW Pp and recognizes pump failed to start.
" Stops 2B EDG in accordance with Continuous Action Summary, prior to applying any loads*
Terminating Cue: After 2B EDG is stopped, state "this JPM is complete".
Nuclear Common SYSTEM:
TASK:
NAME:
DATE:
COMMENTS (Required for UNSAT evaluation) i Rev. 0 Page 4 of 5
NC.TQ-WB.ZZ-0310(Z)
INITIAL CONDITIONS:
The unit was at 100% power with 2B EDG in LOCKOUT for DUTR replacement.
A loss of off-site power occurred and 2A and 2C EDG's failed to start.
2-EOP-LOPA-1 has been implemented up to Step 12. 2B Diesel Generator is ready to start.
INITIATING CUE:
Beginning at Step 12, perform the actions of 2-EOP-LOPA-1.
Nuclear Common 1.
- 2.
3.
Page 5 of 5
NC.TQ-WB.ZZ-031 0(Z)
STATION:
SYSTEM:
TASK:
TASK NUMBER:
JPM NUMBER:
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM Component Cooling Water (008)
Shift Operating CCW Pumps 0080010101 2002 GOLF NRC SRO S7 ALTERNATE PATH:
K/A NUMBER:
IMPORTANCE FACTOR:
APPLICABILITY:
EO RO STA [-3 SRO EVALUATION SETTING/METHOD:
Simulator/Perform
REFERENCES:
S2.OP-SO.CC-0001, Rev. 8 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
5 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
APPROVAL:
X 008000 A4.01 3.3 3.1 RO SRO Minutes REPRESENTATIVE or designee or designee ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: E SAT []
UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Nuclear Common Page 1 of 4 Rev. 0 CAUTION:
No p~ant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRA JOB PERFORMANCE MEASURI NAME:
DATE:
SYSTEM:
TASK:
Component Cooling Water (008)
Shift Operating CCW Pumps TASK NUMBER:
0080010101 INITIAL CONDITIONS:
Unit 2 is at full power.
SIMULATOR SETUP:
- Any Mode 1, 100% power IC.
21 and 22 CCW Pumps in service.
0 CC Surge Tank level between 42-58%
INITIATING CUE:
Shift operating CCW pumps by placing 23 CCW Pump in operation, stopping 21 CCW Pump and placing it in AUTO control.
Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Nuclear Common Page 2 of 4 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
Component Cooling Water TASK:
Shift operating pumps PSTEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
_NO.
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
START TIME:
Operator obtains procedure.
Operator obtains current revision or is provided with a properly marked up copy of S2.OP-SO.CC-0001(Q).
NOTE: Category II procedure use requirements apply.
5.5.1 Ensure CC Surge Tank Level is 42-58%.
Verifies Surge Tank Level indication is within specified range.
5.5.2 IF 2CC131 is selected to AUTO THEN Depresses 2CC131 MANUAL button and place 2CC131 in MANUAL.
verifies indication.
5.5.3 Select MANUAL and START 23 CCW Depresses #23 CCW pump MANUAL Pump.
button Depresses #23 CCW pump START button Verifies amps and flow respond as expected.
5.5.4 STOP 21 CCW Pump.
Depresses #21 CCW pump STOP button 5.5.5 Select one CCW Pump to AUTO.
Depresses the AUTO button for #21 CCW pump 5.5.6 IF 2CC 131 was selected to MANUAL, Depresses the AUTO button for 2CC131 THEN SELECT 2CC131 to AUTO.
STOP TIME:
Terminating Cue: After 2CC131 is in AUTOMATIC then state "this JPM is complete".
Rev. 0 Nuclear Common Page 3 of 4
NC.TQ-WB.ZZ-0310(Z)
INITIAL CONDITIONS:
Unit 2 is at full power.
INITIATING CUE:
Shift operating CCW pumps by placing 23 CCW Pump in operation, stopping 21 CCW Pump and placing it in AUTO control.
Nuclear Common Page 4 of 4
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE STATION:
SALEM SYSTEM:
Containment Cooling System (022)
TASK:
Respond to High Containment Sump Lev TASK NUMBER:
1150370501 JPM NUMBER:
GOLF NRC - SROU S3 ALTERNATE PATH:
K/A NUMBER:
IMPORTANCE FACTOR:
APPLICABILITY:
SRO L-I EVALUATION SETTINGIMETHOD:
Simulator/Perform
REFERENCES:
2-EOP-FRCE-2, Rev. 20 TOOLS AND EQUIPMENT:
None VALIDATED JPM COMPLETION TIME:
8 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
APPROVAL:
/
el (CFCU SW Leak)
E15 EA1.1 2.9 RO 3.0 SRO N/A or designee ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: E SAT-] UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
NucearComonPag 1
f CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
Rev. 0 Nuclear Common Page I of 5
NC.TQ-WB.ZZ-0310(Z)
SYSTEM:
TASK:
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
Containment Cooling System (022)
Respond to High Containment Sump Level (CFCU SW Leak)
TASK NUMBER:
1150370501 INITIAL CONDITIONS:
- 1. A large break LOCA has occurred.
SIMULATOR SETUP:
- 1. Reset to IC-189 INITIATING CUE:
You are the control board operator. Implement 2-EOP-FRCE-2.
Nuclear Common Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Rev. 0 Page 2 of 5
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
Containment Cooling System (022)
TASK:
Respond to High Containment Sump Level (CFCU SW Leak)
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
- _NO.
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
START TIME:
1 Is SW flow to 21-25 CFCUs normal?
Answers NO, after checking SW flow on all CFCU's and determining that #23 is not normal Identify and stop the AFFECTED Stops 23 CFCU CFCU Close SW58 (Inlet Valve) on Closes 23SW58 AFFECTED CFCU Close SW72 (Outlet Valve) on Closes 23SW72 AFFECTED CFCU 1.1 Is 2FP147 (CIV) open?
Checks RP-5 and answers NO 1.2 Is CCW Surge Tk Level dropping in Checks level and answers NO an uncontrolled or unexplained manner?
1.3 Is DEMIN WATER STORAGE TANK CUE: Unit 1 reports DEMIN WATER Level dropping in an uncontrolled or STORAGE TANK level is NOT unexplained manner as determined dropping.
by Unit 1 indication?
1.4 Is PRIMARY WATER STORAGE Checks indication and answers NO TANK Level dropping in an uncontrolled or unexplained manner?
Nuclear Common Rev. 0 Page 3 of 5
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NC.TQ-WB.ZZ-031 0(Z)
NAME:
DATE:
SYSTEM:
Containment Cooling System (022)
TASK:
Respond to High Containment Sump Level (CFCU SW Leak)
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
- ___NO._
(#Denotes a Sequential Step)
STANDARD_
S/U UNSAT evaluation)
STOP TIME:
Terminating Cue: When candidate is preparing to notify Chemistry to sample the CNMT Sump, state "this JPM is complete".
Rev. 0 Nuclear Common Page 4 of 5
NC.TQ-WB.ZZ-031 0(Z)
INITIAL CONDITIONS:
- 1. A large break LOCA has occurred.
INITIATING CUE:
You are the control board operator. Implement 2-EOP-FRCE-2.
Page 5 of 5 Nuclear Common
NC.TQ-WB.ZZ-0310(Z)
STATION:
SYSTEM:
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM ECCS TASK:
TASK NUMBER:
JPM NUMBER:
Shift to the HL Recirculation ECCS mode with 22 RHR Pump OOS 1150110501 2002 GOLF NRC SROI/SROU S2 ALTERNATE PATH:
APPLICABILITY:
EO W
RO W--
K/A NUMBER:
IMPORTANCE FACTOR:
STA 006 A4.07 4.4 4.4 RO SRO SRO EVALUATION SETTING/METHOD:
Simulator/Perform
REFERENCES:
2-EOP-LOCA-4, Rev. 22 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
11 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
'ISARGAINI J G UNIT REPRESEIYTATIVE TRAINING SUPERVISOR or designee 71O*A 0 NS V/ANA GE R or desig'nee CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: F SAT U
ONSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Page 1 of 4 Rev. 0 Nuclear Common
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
Shift to the HL Recirculation ECCS mode with 22 RHR Pump OOS.
TASK NUMBER:
1150110501 INITIAL CONDITIONS:
- 1.
Unit 2 experienced a large break LOCA.
- 2.
The ECCS is aligned for cold leg recirculation.
SIMULATOR SETUP:
- 1. ResettoIC-190 INITIATING CUE:
The CRS has directed you to implement LOCA-4, Transfer to Hot Leg Recirculation.
Nuclear Common SYSTEM:
ECCS TASK:
Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Rev. 0 Page 2 of 4
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
SYSTEM:
ECCS TASK:
Shift to the HL Recirculation ECCS mode with 22 RHR Pump OOS.
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
- __NO._
(#Denotes a Sequential Step)
STANDARD_
S/U UNSAT evaluation)
START TIME:
1 Are both RHR Pumps running?
Answers NO then proceeds to Step 3.
3 Is 22 RHR Pump running?
Answers NO then proceeds to Step 5.
5 Is 21 RHR Pump running?
Answers YES 6
CLOSE 21CS36 (RHR Hx Supply to CS Depresses CLOSE for 21CS36 and verifies Valve).
closed indication.
Is 22SJ45 (RHR Discharge to SI Pumps Answers YES.
Valve) OPEN?
6.1 STOP 21 SI Pump.
Depresses STOP for 221SI Pump and verifies indication.
CLOSE 21SJ134 (Cold Leg Discharge Depresses CLOSE for 21SJ134 and Valve).
verifies indication.
OPEN 21SJ40 (Hot Leg Discharge Depresses OPEN for 21SJ40 and verifies Valve).
indication.
START 21 SI Pump.
Depresses START for 21 SI Pump and verifies indication.
STOP TIME:
Terminating Cue: Returns to procedure in effect. State "this JPM is complete".
Nuclear Common Rev. 0 Page 3 of 4
NC.TQ-WB.ZZ-031 0(Z)
INITIAL CONDITIONS:
- 1.
2.
Unit 2 experienced a large break LOCA.
The ECCS is aligned for cold leg recirculation.
INITIATING CUE:
The CRS has directed you to implement LOCA-4, Transfer to Hot Leg Recirculation.
Nuclear Common Page 4 of 4
STATION:
SYSTEM:
TASK:
TASK NUMBER:
JPM NUMBER:
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM CVCS (004)
Control charging flow after Control Room evacuation.
1130070501 2002 GOLF NRC RO P1 ALTERNATE PATH:
APPLICABILITY:
EO --
K/A NUMBER:
IMPORTANCE FACTOR:
RO STA L-068 AA1.22 4.0 RO 4.3 SRO SROFT EVALUATION SETTING/METHOD:
Plant/Simulate
REFERENCES:
S2.OP-AB.CR-0001, Rev. 11 TOOLS AND EQUIPMENT:
JAM Key VALIDATED JPM COMPLETION TIME:
15 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
SARO3AIN 4G UNIT REPRESEITATIVE I
UPERVISOR or designee OPERATIONS MIANAGER or designee CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE:0 SAT
] UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
I Page 1 of 5 Rev. 0 Nuclear Common
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
CVCS (004)
Control charging flow after Control Room evacuation.
TASK NUMBER:
1130070501 INITIAL CONDITIONS:
1 The Control Room has been evacuated in accordance with AB.CR-0001, Control Room Evacuation.
- 2.
A reactor trip from 100% was initiated prior to evacuating the Control Room.
SIMULATOR SETUP:
N/A INITIATING CUE:
You have been directed to take local control of charging flow per AB.CR-1, Att. 5, Step 8.0. Steps 1.0-7.0 have been completed.
Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Nuclear Common SYSTEM:
TASK:
Rev. 0 Page 2 of 5
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE Control charging flow after Control Room evacuation.
Nuclear Common SYSTEM:
CVCS (004)
TASK:
NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
START TIME:
Operator reviews a copy of Evaluator provides copy of Attachment 5.
S2.OP-AB.CR-0001, Att. 5, and proceeds to Charging Pump Alley, El. 84.
NOTE: Category I procedure use requirements apply.
8.0 Take local control of 2CV55, Cent. Chg Locates the local control panel in the Pump Flow Control Valve, by performing Charging Pump alley the following:
8.1 Record the charging flow as indicated Records charging flow.
on 2FI-128A.
8.2 0 Place local E/P Bypass Line Selector
- Places local E/P Bypass Line Selector in Valve in MAN.
MANUAL.
8.3 Using MANUAL hand air operator, CUE: Charging flow rate is acceptable as ensure that the flow rate as noted is indicated and is stable.
being maintained by CV55.
8.4 Observe air pressure indicator at the CUE:
Air pressure is approximately 9 psi MANUAL/AUTO Station to verify local control.
Page 3 of 5 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
CVCS (004)
TASK:
Control charging flow after Control Room evacuation.
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation) 9.0 Notify the STA and HSD Panel Operator Locates page or phone.
that Steps 1.0-8.0 of Att. 5 are completed.
CUE: Acknowledge report. Adjust charging flow to 75 gpm (or a value not currently read on FI-128A).
Adjusts flow using MANUAL hand air Raises air pressure to raise flow or operator.
vice-versa.
CUE: Provide feedback as to whether flow has increased or decreased STOP TIME:
Terminating Cue: Adjusts air pressure to match increase or decrease flow cue. State "this JPM is terminated".
Nuclear Common Rev. 0 Page 4 of 5
NC.TQ-WB.ZZ-0310(Z)
INITIAL
- 1.
2.
CONDITIONS:
The Control Room has been evacuated in accordance with AB.CR-0001, Control Room Evacuation.
A reactor trip from 100% was initiated prior to evacuating the Control Room.
INITIATING CUE:
You have been directed to take local control of charging flow per AB.CR-1, Aft. 5, Step 8.0. Steps 1.0-7.0 have been completed.
Nuclear Common Page 5 of 5
_L AC-.,\\-iO-T-SPOT CHANGES MUST BE ATTACHED FOR FIELD S
ATTACHMENT 5 (Page 1 of 4)
REACTOR OPERATOR OBTAIN the following:
One copy of this procedure.
One radio (located in Appendix "R" Cabinet)
Key ring set and tools (Security Master, JA Master, Breaker Keyswitch, screwdriver and adjustable wrench).
NOTE Steps 2.0 through 4.0 will be performed in the 460V Vital Bus Room-El 84'.
/4t2.0 PROCEED to Rod Drive MG Set Control Panel, AND OPEN the following breakers:
J*
2.1 f*2.2
'It2.3
/ ýý-2.4 3.0 Reactor Trip Breaker A Reactor Trip Breaker B Reactor Trip Bypass Breaker A Reactor Trip Bypass Breaker B.
CONFIRM with the Operator at the Hot Shutdown Panel that 21 or 22 Charging Pump is operating.
4.0 PROCEED to 2AX1AX7X, #23 Charging Pump, breaker AND TRIP the breaker.
5.0 PROCEED to 2C West Valve & Misc 230V Control Center-El 84',
AND OPEN Breaker 2CY2AX4I, 2CV175-Rapid Borate Stop Valve.
6.0 NOTIFY the CRS that the Reactor Trip and Bypass breakers, and #23 Charging Pump Breaker are OPEN.
7.0 CONFIRM with NEO #1 that 2CV71, Chr Hdr PCV, is isolated (2CV70) and bypassed (2CV73) and that flow is being maintained to RCP seals at flowrate of 6 to 10 gpm to each seal.
Page 25 of 83 s2.OP-AB.CR-0001(Q)
[C03631 Sr7;d1.0 1191-1 al Salem 2 Rev. 11
-7AC-V O-T---
S-ANGES MUST BE ATTACHED
-Sý s2.oP-AB.CR-0001(Q)
ATTACHMENT 5 (Page 2 of 4)
REACTOR OPERATOR NOTE The following indications and controls are available for local operation at Unit 2 CVC Chg Prmps FL & PR Inst Pnl, Panel 216-2:
2CV55 AUTO/MANUAL Selector Switch (2HC-128G No. 21 & 22 Charging Pumps Flow to Regen HX) 2CV55 Manual HAND/AIR Regulator Control Charging Pump Flow Indication, 2F1-1 28A 21 and 22 Charging Pump Pressure Indication, 2PI-142B VCT Level Indication 2LT-1 14.
8.0 TAKE control of 2CV55, Cent Chg Pmp Flow Cont Valve, by performing the following:
8.1 RECORD the charging flow as indicated on 2FI-128A.
gpm indicated on 2FI-128A 8.2 PLACE local E/P Bypass Line Selector Valve in Manual.
8.3 Using the MANUAL hand air operator, ENSURE that the flow rate as noted in Step 8.1 is being maintained with 2CV55.
8.4 OBSERVE local air pressure indicator to verify local control.
9.0 NOTIFY the CRS and STA that steps 1 through 8 of Attachment 5 are completed.
Rev. 11 Page 26 of 83 Salem 2
7; AV7VE ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD USE ATTACHMENT 5 (Page 3 of 4)
REACTOR OPERATOR s2.oP-AB.cR-01(Q) 10.0 WHEN directed by the CRS, THEN:
10.1 PROCEED to Unit 2 Cont Air Redundant Air Supply Wall Mntd Pnl 701-2A, El 122', near the Boric Acid Storage Tanks.
10.2 CLOSE the Air Supply Isolation Valve, 21CV160 A/S, 21CV160 LOCAL AIR SUPPLY.
10.3 OPEN draincock for control air regulator for 21CV160.
10.4 PROCEED to Unit 2 Cont Air Redundant Air Supply Wall Mntd Pnl 701-2B, El 122", near the Boric Acid Storage Tanks.
10.5 CLOSE the Air Supply Isolation Valve, 22CV160 A/S, 22CV160 LOCAL AIR SUPPLY.
10.6 OPEN draincock for control air regulator for 22CV160.
10.7 OPEN 2CV175, Rapid Borate Stop Valve.
10.8 PROCEED to 2CV55 and ADJUST the flow for 75 gpm above existing total flow for all RCP seal flows.
11.0 REQUEST NEO #1 to adjust 2CV73 to maintain flow to RCP seals between 6 and 10 gpm.
12.0 NOTIFY the operator at the CRS that Rapid Boration has commenced.
13.0 REMAIN in the area of the Charging Pumps.
Page 27 of 83 NOTE Step 10.0 through Step 15.0 will only be performed if an Emergency Boration is required for stuck rod.
S ae2 Rev. 11
ACTIVE ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD JSE D21015_
ATTACHMENT 5 (Page 4 of 4)
REACTOR OPERATOR 14.0 WHEN directed by CRS to terminate Rapid Boration, THEN:
S.OP-AB.cR-ooo0(Q 14.1 IF necessary, THEN ADJUST 2CV55 to reduce flow to maintain Pressurizer level.
14.2 REQUEST the operator in the Inner Pen Area to adjust 2CV73 to maintain RCP Seal flow between 6 and 10 gpm for each RCP seal.
14.3 PROCEED to Unit 2 Cont Air Redundant Air Supply Wall Mntd Pnl 701-2A, El 122', near the Boric Acid Storage Tanks.
14.4 CLOSE draincock for control air regulator for 21CV160, BA Xfr Recirc Cont Valve.
14.5 OPEN the Air Supply Isolation Valve, 21CV160 A/S, 21CV160 LOCAL AIR SUPPLY.
14.6 PROCEED to Unit 2 Cont Air Redundant Air Supply Wall Mntd Pnl 701-2B, El 122", near the Boric Acid Storage Tanks.
14.7 CLOSE draincock for control air regulator for 22CV160, BAT Recirc Cont Valve.
14.8 OPEN the Air Supply Isolation Valve, 22CV160 A/S, 22CV160 LOCAL AIR SUPPLY.
14.9 CLOSE 2CV175, Rapid Borate Stop Valve.
15.0 NOTIFY CRS that Rapid Boration is terminated.
16.0 PROCEED to the Hot Shutdown Panel and assist where necessary.
Page 28 of 83 Rev. I11 S emn2
STATION:
SYSTEM:
TASK:
TASK NUMBER:
JPM NUMBER:
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM 1 & 2 MRSS (035)
Locally close a Main Steamline Isolation Valve (MS167) and operate the associated Atmospheric Steam Relief Valve (MS1 0).
1140130401 2002 GOLF NRC RO P2 ALTERNATE PATH:
APPLICABILITY:
EO --
K/A NUMBER:
IMPORTANCE FACTOR:
ROW-STA 068 AA1.01 4.3 4.5 RO SRO SRO EVALUATION SETTING/METHOD:
Plant/Simulate
REFERENCES:
S2.OP-AB.CR-0001, Rev. 11 TOOLS AND EQUIPMENT:
Adjustable Wrench, Flashlight VALIDATED JPM COMPLETION TIME:
15 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
BAGAININ UNIT REPRESENT TIVE 7
TRAINING SUPERVISOR or designee OPERATIONS,IMANAGER or designee
/
CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE:
7 SAT D UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Z
ý Z; "/,
X,
'I"A
- f k V, 0", W4-Rev. 0 Nuclear Common Page 1 of 5
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
MRSS (035)
Locally close a Main Steamline Isolation Valve (MS167) and operate the associated Atmospheric Steam Relief Valve (MS10).
TASK NUMBER:
1140130401 INITIAL CONDITIONS:
1 A Control Room Evacuation has taken place due to a noxious fumes problem.
- 2.
A manual trip was initiated from 100% power.
- 3.
S2-OP-AB.CR-0001 is being utilized to control the plant.
SIMULATOR SETUP:
N/A INITIATING CUE:
The CRS has directed you to locally close 21MS167, place 21MS10 in LOCAL and then standby to operate 21MS10. The operations are to be accomplished JAW S2.OP-AB.CR-0001, Attachment 7, Step 7, 9 and Step 14. The other steps of the attachment have been completed or are being performed by another operator Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Nuclear Common SYSTEM:
TASK:
Rev. 0 Page 2 of 5
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
MRSS (035)
TASK:
Locally close 21MS167 and operate 21MS10 PSTEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
"_NO.
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
START TIME:
Evaluator should provide a marked up copy Obtains a copy of the procedure.
of S2.OP-AB-CR-0001, Attachment 7.
NOTE: Category 1 procedure use standards apply.
1 (9.0)
Proceed to 21 Mn Stm & Trb Bypass Stm Gen Press Cont PnI 684-2A, and perform the following for 21MS10:
(9.1)
PLACE the selector valve in the E/P 21 MS1 0 selector valve to LOCAL.
bypass line to the LOCAL position (9.2)
- Operate hand sender in E/P line to PL-8907 should indicate zero.
ensure that PL-8907 indicates zero.
2 (14.0)
PERFORM either of the following to Main Steam Isolate 21MS167, MSIV:
(14.1)
Perform the following to fail open NOTE: If Candidate chose Panel 689-2A 21 MS171, MS ISOL VLV STM ASSIST, at these steps will NOT be performed.
No. 2 Unit Main Steam Vent VLV Control Panel 688-2A:
(14.1.A)
Close 2CA1318, SUP TO PNL 688-2A.
Closes 2CA1318, SUP TO PNL 688-2A.
(14.1. B)
- Close 2CA1319, SUP TO PNL 688-2A Closes 2CA1319, SUP TO PNL 688-2A (14.1.C)
° Open drain-cock of pressure regulator Opens drain-cock for pressure regulator.
for SV275 (inside Panel 688-2A)
CUE: 21MS167 closed.
Rev. 0 Nuclear Common Page 3 of 5
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
SYSTEM:
MRSS (035)
TASK:
Locally close 21 MS167 and operate 21MS10 STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
(14.2)
Perform the following to fail open NOTE: If Candidate chose Panel 688-2A 21 MS169, MS ISOL VLV STM ASSIST, at these steps will NOT be performed.
No. 2 Unit Main Steam Vent VLV Control Panel 689-2A:
(14.2.A)
- Close 2CA1 320, SUP TO PNL 689-2A.
Closes 2CA1320, SUP TO PNL 689-2A.
(14.2.B)
- Close 2CA1321, SUP TO PNL 689-2A Closes 2CA1321, SUP TO PNL 689-2A (14.2.C) e Open drain-cock of pressure regulator Opens drain-cock for pressure regulator.
for SV274 (inside Panel 689-2A)
CUE: 21MS167 closed.
3 Makes report to HSD Panel Operator.
CUE: Acknowledge report. Open 21MS10 approximately 50%
4 OPERATE hand sender in E/P line to Candidate returns to 21 Mn Stm & Trb increase pressure indicated on PL-8907.
Bypass Stm Gen Press Cont Pnl 684-2A and operates hand sender to raise air pressure* to approx. 8-12 psig on PL-8907.
CUE: Provide feedback consistent with action (21MS10 is opening)
STOP TIME:
Terminating Cue: Acknowledge report/action and state "this JPM is complete".
Nuclear Common Page 4 of 5 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
INITIAL CONDITIONS:
- 1.
A Control Room Evacuation has taken place due to a noxious fumes problem.
- 2.
A manual trip was initiated from 100% power.
- 3.
S2-OP-AB.CR-0001 is being utilized to control the plant.
INITIATING CUE:
The CRS has directed you to locally close 21MS167, place 21MS10 in LOCAL and then standby to operate 21MS10. The operations are to be accomplished lAW S2.OP AB.CR-0001, Attachment 7, Step 7, 9 and Step 14. The other steps of the attachment have been completed or are being performed by another operator.
Nuclear Common Page 5 of 5
N-THE-SPOT C-ANGES MUST BE AT:AS-z.
-- ELD USE S2.OP-AB.CR-01(Q)
ATTACBNMENT 7 (Page 1 of 7)
- 1 NEO Operator rFfr
1.0 OBTAIN the following:
One copy of this procedure.
One radio (located in Appendix "R" Cabinet)
Key ring set and tools (Security Master, JA Master, Breaker Keyswitch, screwdriver and adjustable wrench).
2.0 DEFEAT Safety Injection by opening the following breakers:
.1 Breaker 2AVIB5, Reactor Protection Output Cabinet Train A #103 in 2A 1l5VAC Vital Instrument Bus for Train "A" in Relay Room Elev 100'.
/_
2.2 Breaker 2AVIB24, 2A Safeguard Emergency Cabinet.
2.3 Breaker 2BVIB8, Reactor Protection Output Cabinet Train B #37 in 2B 115 VAC Vital Instrument Bus for Train "B" in Relay Room Elev 100'.
.4 Breaker 2BVIB27, 2B Safeguard Emergency Cabinet.
- ,14 2.5 Breaker 2CVIB9, 2C Safeguard Emergency Cabinet.
[C03631 6ýL&3.0 f
- 4. 0 REQUEST Charging flow rate from the RO who is performing Attachment 5.
PROCEED to 2CV70, Chg Hdr PCV Inlet Vlv, and 2CV73, Chg Hd PCV Byp Valve, AND SIMIULTANEOUSLY CLOSE 2CV70 while OPENING 2CV73.
After 2CV70 is CLOSED, REQUEST the charging flowrate from RO, AND ADJUST 2CV73 to the flowrate identified in Step 3.0.
Page 33 of 83 NOTE The following steps will be performed in Mech Pen, Elev 78'.
The following steps assume the charging system was in a normal operating condition prior to Control Room evacuation.
2ýfý Salem 2 Rev. 11
ON-THE-SPOT CHANGES MIST BE ATTACHED FOý IELD SE S2.OP-AB.CR-0001(Q)
ATTACHMENT 7 (Page 2 of 7)
- 1 NEO Operator S6.0 VERIFY that a 6-10 gpm flow is maintained for each RCP pump seal as indicated on the following:
T1t 6.1 2FI144A, 21 CVC React Cool Pmp Seal Water Flow Ind 916.2 2FI143A, 22 CVC React Cool Pmp Seal Water Flow Ind It 6.3 2FI116A, 23 CVC React Cool Prop Seal Water Flow Ind fl -6.4 2FI1 15A, 24 CVC React Cool Pmp Seal Water Flow Ind 7.0 PROCEED to the Inner Pen Area.
CAUTION The following steps, MSIV Isolation, should be coordinated with the CRS.
9-6 8.0 PROCEED to No. 21 Steam Gen Press Cont Pnl, 683-2A, CLOSE 21MS18A/S, A/S to SV587 in Pnl 683-2A.
9.0 PROCEED to No. 21 Mn Stm & Trb Bypass Stm Gen Press Cont Pnl, 684-2A, AND PERFORM the following for 21MS10 Atmospheric Relief Valve:
9.1 PLACE the selector valve in E/P bypass line to LOCAL position.
9.2 OPERATE hand sender in E/P line to ensure that PL-8907 indicates zero.
,jt*-
10.0 PROCEED to No. 23 Steam Gen Press Cont Pnl, 683-2C, CLOSE 23MS18A/S, A/S to SV585 in Pnl 683-2C.
,J-(4 11.0 PROCEED to 23 Mn Stm & Trb Bypass Stm Gen Press Cont Pnl, 684-2C, AND PERFORM the following for 23MS10 Atmospheric Relief Valve:
.)L&
11.1 PLACE the selector valve in B/P bypass line to LOCAL position.
1% 11.2 OPERATE hand sender in E/P line to ensure that PL-8909 indicates zero.
Page 34 of 83 Salem 2 Rev. 11
ILL ACTIVE ON-0-HE-SPOT CHANGES MUST BE ATTACHED FOR FIELD USE 0021015 s2.oP-AB.CR-0001(Q)
ATTACHMENT 7 (Page 3 of 7)
- 1 NEO Operator
)J(A 12.0 At 23MS18, OPEN the drain cock on the pressure regulator.
A) It 13.0 At 21MS18, OPEN the drain cock on the pressure regulator.
14.0 PERFORM either of the following to Main Steam Isolate 21MS167, MS ISOL VLV:
NOTE It is only necessary to fail either 21MS171 or 21MS169 to CLOSE 21MS167.
CAUTION Steam hazard when opening 21MS169 or 21MS171 because of telltale leakoff drain pinholes downstream of valves.
14.1 PERFORM the following to fail open 21MS171, MS ISO V STEAM ASSIST, at No. 2 Unit Main Stm Vent Vlv Control Panel 688-2A:
A CLOSE 2CA1318, SUP TO PNL 688-2A.
B CLOSE 2CA1319, SUP TO PNL 688-2A.
C OPEN drain cock of pressure regulator for SV-275 (located inside No. 2 Unit Main Stm Vent Vlv Control Panel 688-2A).
OR 14.2 PERFORM the following to fail open 21MS169, MS ISOL V STEAM ASSIST, at No. 2 Unit Main Stm Vent Vlv Control Panel 689-2A:
A CLOSE 2CA1320, SUP TO PNL 689-2A.
B CLOSE 2CA1321, SUP TO PNL 689-2A.
C OPEN drain cock of pressure regulator for SV-274 (located inside No. 2 Unit Main Stn Vent Vlv Control Panel 689-2A).
Salem 2 Pv 3,, -f
%;;vl
¥.
AC TVE ON-THE-SPOT CHANGES MUST BE ATTACHE? FOR FIELD USE Q1ý 115 s2.OP-AB.CR-0001(Q)
ATTACHMENT 7 (Page 6 of 7)
- 1 NEO Operator 23.0 PERFORM either of the following to Main Steam Isolate 22MS167, MS ISOL VLV:
NOTE It is only necessary to fail either 22MS171 or 22MS169 to CLOSE 22MS1 67.
CAUTION Steam hazard when opening 22MS169 or 22MS171 because of telltale leakoff drain pinholes downstream of valves.
23.1 A4A?
)iK 23.2 PERFORM the following to fail open 22MS171, MS ISO V STEAM ASSIST, inside No. 2 Unit Main Stm Vent Vlv Control Panel 688-2B:
A.
CLOSE 22MS171-A/S, 22MS171 AIR SUPPLY.
B.
OPEN draincock of pressure regulator for SV-281.
OR PERFORM the following to fail open 22MS169, MS ISO V STEAM ASSIST, inside No. 2 Unit Main Stm Vent Vlv Control Panel 689-2B:
A. CLOSE 22MS169-A/S, 22MS169 AIR SUPPLY.
B.
OPEN draincock of pressure regulator for SV-280.
Rev. 11 Page 38 of 83 I3ŽLA Salem2
L ACTIVE ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD JSE 1021015 s2.OP-AB.CR-0001(Q)
ATTACHMENT 7 (Page 7 of 7)
- 1 NEO Operator
'{
24.0 PERFORM either of the following to Main Steam Isolate 24MS167, MS ISOL VLV:
NOTE It is only necessary to fail either 24MS1 71 or 24MS1 69 to CLOSE 24MS1 67.
CAUTION Steam hazard when opening 24MS169 or 24MS171 because of telltale leakoff drain pinholes downstream of valves.
4k 24.1 PERFORM the following to fail open 24MS171, MS ISO V STEAM ASSIST, inside No. 2 Unit Main Stm Vent Vlv Control Panel 688-2D:
Aj4 A.
CLOSE 24MS171-A/S, 24MS171 AIR SUPPLY.
B.
OPEN draincock of pressure regulator for SV-285.
OR 24.2 PERFORM the following to fail open 24MS169, MS ISO V STEAM ASSIST, inside No. 2 Unit Main Stm Vent Vlv Control Panel 689-2D:
A.
CLOSE 24MS169-A/S, 24MS169 AIR SUPPLY.
B.
OPEN draincock of pressure regulator for SV-284.
25.0 NOTIFY the CRS and STA that steps 1 through 24 of Attachment 7 are completed.
26.0 REMAIN in the Outer Pen Area.
CAUTION When operating hand sender in E/P bypass line, DO NOT exceed a maximum of 20 psig indicated pressure on PL-8909 & PL-8910 27.0 When directed by the CRS, SLOWLY THROTTLE OPEN 22 & 24 MS1Os and MAINTAIN Steam Generator Pressures @ 1005 psig (Tave = 547"F), by operating the hand sender in E/P bypass line at No. 2 Unit 22 & 24 Steam Generator Press Control Panels 684-2B and 684-2D respectively.
28.0 VERIFY opening of the MS10s by observing pressure indication on PL-8908 and PL-8910, respectively.
Page 39 of 83 Salem2 Rev. 11
STATION:
SYSTEM:
TASK:
TASK NUMBER:
JPM NUMBER:
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM RPS (012)
Locally open the Reactor Trip Breakers and the Rod Drive MG Set Breakers 1130110501 2002 GOLF NRC RO P3 ALTERNATE PATH:
APPLICABILITY:
EO W
RO W
K/A NUMBER:
IMPORTANCE FACTOR:
STA r=
SRO 2.1.30 3.9 RO 3.4 SRO EVALUATION SETTING/METHOD:
Plant/Simulate
REFERENCES:
EOP-FRSM-1 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
5 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
B AINING UIT REPRESENTATI E dTRAINsINgne or designee OPERATIO*I MANAGER or designee CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE:
1--
SAT 0 UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Rev. 0 Page I of 4 Nuclear Common
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
RPS (012)
Locally open the Reactor Trip breakers and the Rod Drive MG Set breakers.
TASK NUMBER:
1130110501 INITIAL CONDITIONS:
- 1.
The Unit 2 reactor was at 100% when a reactor trip was demanded.
- 2.
All efforts to trip the reactor from the Control Room have been unsuccessful.
SIMULATOR SETUP:
N/A INITIATING CUE:
In accordance with 2-EOP-FRSM-1, the CRS has directed you to open the Unit 2 reactor trip breakers and rod drive MG set breakers using their local controls.
Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Nuclear Common SYSTEM:
TASK:
Page 2 of 4 Rev. 0
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
SYSTEM:
RPS (012)
TASK:
Locally open the Reactor Trip breakers and the Rod Drive MG Set breakers.
Terminating Cue: Acknowledge report and then state "this JPM is complete".
Nuclear Common
.1 STEP COMMENTS
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
SIU UNSAT evaluation)
START TIME:
This is a "skill of the operator" task Proceed to the Electrical Switchgear Operator enters the correct Unit Electrical Room (El 84).
Switchgear Room.
Trips the Reactor Trip Breakers.
Operator identifies the correct breakers, describes how to remove the trip guard and depresses the trip pushbutton on at least one breaker.
CUE: For each breaker "the breaker is OPEN".
Trips Rod Drive MG Sets.
Operator identifies the correct breakers and trips BOTH Rod Drive MG Sets by opening at least a motor or generator breaker on each MG set CUE: For each breaker operated "the breaker is OPEN".
Notifies control room Locates nearest page or phone STOP TIME:
Page.3 of 4 Rev. 0
NC.TQ-WB.ZZ-031 0(Z)
INITIAL CONDITIONS:
- 1.
The Unit 2 reactor was at 100% when a reactor trip was demanded.
- 2.
All efforts to trip the reactor from the Control Room have been unsuccessful.
INITIATING CUE:
In accordance with 2-EOP-FRSM-1, the CRS has directed you to open the Unit 2 reactor trip breakers and rod drive MG set breakers using their local controls.
Nuclear Common Page 4 of 4
STATION:
SYSTEM:
TASK:
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM AFW Align AFW to an Alternate Source - DM Water TASK NUMBER:
JPM NUMBER:
ALTERNATE PATH:
APPLICABILITY:
EO =
1130050501 2002 GOLF NRC SROI/SROU P1 ROLT-Z K/A NUMBER:
IMPORTANCE FACTOR:
=
SRO W 2.1.30 3.9 3.4 RO SRO EVALUATION SETTING/METHOD:
Plant/Simulate
REFERENCES:
S2.OP-SO.AF-0001, Rev. 21 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
15 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
NA APPROVAL:
GAINING NIT REPRESENT TIVE
-- `IRAINIING SUPERVISOR or designee OPERATIONS ý'ANAGER or designee CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: F7SAT
] UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
Rev. 0 Nuclear Common Page 1 of 7
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
Align AFW to an Alternate Source - DM Water.
- 1.
The unit is in HSB with AFW supplying the SG's. An accident involving a large truck has caused a hole in the AFWST.
SIMULATOR SETUP:
N/A INITIATING CUE:
Align the Demineralized Water Tanks to the AFW pump suction lAW S2.OP-SO.AF-0001. Another Operator is standing by to operate valves located outside the RCA. Inform the Evaluator when a valve located outside of the Control Point must be operated. The AF52 valves will be operated from the Control Room in accordance with Step 5.8.2.D of the procedure.
Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Nuclear Common SYSTEM:
AFW TASK:
TASK NUMBER:
INITIAL CONDITIONS:
Rev. 0 Page 2 of 7
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
AFW Alian AFW PumD Suction header to DMST NAME:
DATE:
PSTEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
- __NO.__
(#Denotes a Sequential Step)
STANDARD_
SIU UNSAT evaluation)
START TIME:
Operator reviews applicable sections of Evaluator provides copy of properly marked S2.OP-SO.AF-0001 (Q).
up procedure and Attachment 4.
NOTE: Category II procedure use requirements apply.
CUE:
Step 5.8.2.A has been completed.
Beginning at Step 5.8.2.B, perform the NEO steps. The AFW PUMP BACKUP SUCTION VALVES (21, 22, 23AF52) valves will be operated from the control room.
5.8.2.B: Direct NEO to align DMWater to AFW lAW Attachment 4.
Att. 4, 1.0 CLOSE the following ALTERNATE NOTE: sequence Critical to close drains in SUCTION PIPING DRAIN VALVEs:
1.0 prior to performing 2.0 e
2AF94 (Elev. 64 Switchgear Room)
Candidate should indicate AF94 valves are located outside the Control Point 0 1AF94 (Elev. 64 Switchgear Room)
CUE: The Operator outside the control point has closed the AF94's 1AF142 (Elev. 64 Aux Bldg., near 1 Locates 1AF142, 1AF95 and 2AF95 Waste Monitor Hold-up Tank Pump)
(directly below AFW pumps on 64' El.) and simulates closing.
1AF95 (Elev. 64 Aux Bldg. corridor)
- 2AF95 (Elev. 64 Aux Bldg. corridor)
Nuclear Common TASK:
Rev. 0 Page 3 of 7
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE Alian AFW Pumn Suction header to DMST NAME:
DATE:
STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
_NO.
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
UNIT 2 OPEN 1AF51, AF BU TIE TO ALT Candidate should indicate 1AF51 valve is Only 2.0 WTR SUP VALVE (Elev. 84' outside located outside the Control Point Swgr. Rms.)
CUE: The Operator outside the control point has opened 1AF51.
3.0 SLOWLY OPEN 1 DM254, AFW PUMP Candidate should indicate 1 DM254 valve is DM WTR SUP LINE FILL VALVE, to fill located outside the Control Point AFW Pumps alternate suction piping (Elev. 88' TGA, above 15 TGA Sump CUE: Operator outside the control point Pump).
has slowly opened 1DM254.
4.0 IF any AUTO VENT valve fails to close after all air is expelled from alternate suction piping, THEN CLOSE associated AUTO VENT ISOL VALVE:
Unit 1: 1DM256, 1AF137, 1AF139, CUE: The NEO located outside the Control 11AF141, 12AF141, 13AF141 Point reports that 1DM256 and 1AF137 are closed. A Unit 1 NEO reports all Unit 1 AUTO VENT valves are closed. Check only the Unit 2 AUTO VENT valves.
Unit 2: 2AF139, 21AF141, 22AF141, 23AF141 Locates:
- AF141's-directly above each respective AF52.
- 2AF139-next to the AFW/SW spoolpiece CUE: As each valve is located the AUTO VENT valve is closed.
Rev. 0 Nuclear Common SYSTEM:
AFW TA VI*
I Page 4 of 7
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NC.TQ-WB.ZZ-031 0(Z)
NAME:
DATE:
SYSTEM:
AFW TASK:
Align AFW Pump Suction header to DMST STEP COMMENTS STE STEP NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
___NO__
(#Denotes a Sequential Step)
S/U UNSAT evaluation) 5.0 When suction piping is filled, OPEN Candidate should indicate 1DM216 valve is 1DM216, AF PUMP DM WTR SUP located outside the Control Point VALVE (Elev. 84' TGA)
CUE: Alternate Suction piping is full.
1DM216 is open.
6.0 CLOSE 1 DM254.
CUE: Operator outside the control point has closed 1DM254.
7.0 NOTIFY NCO that DM Water is aligned Notifies Control Room by page.
to alternate suction piping.
CUE: Continue with the steps of SO.AF-0001 for Control Room operation of AFW Pp Backup Suction Valves.
5.8.2.C If AUXILIARY FEED PUMP BACKUP N/A's steps for local operation.
SUCTION VALVES are to be operated locally 5.8.2.D.
If AUXILIARY FEED PUMP BACKUP Proceeds with Step 5.8.2.D SUCTION VALVES are to be operated from the Control Room, THEN:
1 Open air supplies to: 21, 22, 23AF52 Locates the air supply valve for at least one valves.
AF52 inside the respective AF Panel (205, 206, 207). The Evaluator may elect to just have the Candidate point out the other two panels.
_____________________________________________________________I Nuclear Common Rev. 0 Page 5 of 7
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
AFW Align AFW Pump Suction header to DMST NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation) 2 Locally UNJACK: 21, 22, 23AF52 Locates all AF52 valves and demonstrates valves.
how to UNJACK one of them. (Removes locking collar and jacking wheel)
CUE: 21, 22, 23AF52's are UNJACKED.
Reports AF52 status to Control Room.
3 Open the following valves from the CUE:
21, 22, and 23AF52 are open.
Control Room:
f 21-23AF52 5.8.2.E CLOSE AFW Pp SUCTION VALVES:
Locates each valve and demonstrates how 21, 22, and 23AF3.
to close at least one.
STOP TIME:
Terminating Cue: Acknowledge 21, 22, 23AF3 closed and state "this JPM is complete."
Nuclear Common TASK:
Rev. 0 Page 6 of 7
NC.TQ-WB.ZZ-031 0(Z)
INITIAL CONDITIONS:
- 1. The unit is in HSB with AFW supplying the SG's. An accident involving a large truck has caused a hole in the AFWST.
INITIATING CUE:
Align the Demineralized Water Tanks to the AFW pump suction lAW S2.OP-SO.AF-0001. Another Operator is standing by to operate valves located outside the RCA. Inform the Evaluator when a valve located outside of the Control Point must be operated. The AF52 valves will be operated from the Control Room in accordance with Step 5.8.2.D of the procedure.
Nuclear Common Page 7 of 7
ON-THE-SPOT C ANGES MUST BE ATACHED
-FIELD USE PSEG Internal Use Only PSEG NUCLEAR L.L.C.
SALEM/OPERATIONS S2.OP-SO.AF-0001(Q) - REV. 21 AUXILIARY FEEDWATER SYSTEM OPERATION USE CATEGORY: II FIELD COPY EXISTS Biennial Review Performed: Yes No _'_ N/A Change Package(s) and Affected Document Number(s) incorporated into this revision: None OTSC(s) incorporated into this Revision: None REVISION
SUMMARY
1.1.3 and Sections 5.5 and 5.6 - added to provide direction in the swapping of Auxiliary Feedwater to the Steam Generators from the Motor Driven Pumps to the Steam Driven Pump and back again.
(80043192)
Updated to incorporate current administrative standards for format and personnel titles. Due to the number of editorial changes, no revision bars were used.
IMPLEMENTATION REQUIREMENTS Effective Date None APPROVED:
Operations Manager - Salem Page 1_L of 1 Date
I
,A-.E ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD USE 2
5s 2.OP-SO.AF-0001 (Q)
AUXILIARY FEEDWATER SYSTEM OPERATION TABLE OF CONTENTS SECTION 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Rev. 21 Page 1 of 78 TITLE PAGE PU R PO SE.............................................. 3 PREREQUISITES.
3 PRECAUTIONS AND LIMITATIONS 4
EQUIPMENT/MATERIAL REQUIRED 6
PRO CED U RE 7
5.1 AFW System Fill and Vent 7
5.2 Feeding Steam Generators with Motor-Driven AFW Pump(s)........
10 5.3 Feeding Steam Generators with Turbine-Driven AFW Pump 15 5.4 Transferring From CN Pumps to AFW Pumps for Steam Generator Level Control.
22 5.5 Transferring from Motor Driven AFW Pumps to Steam Driven AFW Pump for Steam Generator Level Control.
24 5.6 Transferring from Steam Driven AFW Pump to Motor Driven AFW Pumps for Steam Generator Level Control........................
30 5.7 AFW System Mode 1, 2, and 3 Standby Alignment...............
36 5.8 Alternate Water Source Alignments........................
38 5.9 Restoring AFW Pumps Suction to AFWST....................
43 5.10 Preparation for Draining the AFWST 47 5.11 Slow Start Turbine-Driven AFW Pump 48 5.12 Completion and Review...............................
55 REC ORD S
. 56 REFERENCES..........................................
56 Salem 2
_L ^--
ON-THE-SPO-
ý-ANGES MUST BE ATTAC-ED
-OR
-'L
, S 21'_
D 15 AUXILIARY FEEDWATER SYSTEM OPERATION TABLE OF CONTENTS ATTACHMENTS AFW System Fill and Vent............................
58 Turbine-Driven AFW Pump Restoration.......................
60 Independent Verification Mode 1, 2, & 3 AFW Standby Alignment 64 Demin Water to AFW Alignment.........................
65 Fire Water to AFW Alignment..........................
67 Service Water to AFW Alignment 69 Restoration from Alternate Water Sources.....................
72 Restoration of Turbine Driven AFW Pump After Slow Start........
76 Completion Sign-Off Sheet.............................
77 Rev. 21 Page 2 of 78 S2.OP-SO.AF-0001(Q)
Salem 2
AC-VE ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD USE s2.OP-SO.AF-OOO1(Q) 1.0 PURPOSE 1.1 To provide instructions necessary to:
1.1.1 Fill and Vent Aux Feedwater (AFW) System.
1.1.2 Feed Steam Generators with AFW Pumps.
1.1.3 Transfer between Motor Driven and Steam Driven AFW Pumps to feed Steam Generators.
1.1.4 Align AFW System for operation in Modes 1, 2, and 3 lAW Technical Specification 3.7.1.2.
1.1.5 Remove AFW System from AFW Storage Tank (AFWST) and align to alternate water sources.
1.1.6 Remove AFW System from alternate water sources and align to AFWST.
1.1.7 Prepare to drain AFW Storage Tank (AFWST).
1.1.8 Slow start Turbine-Driven AFW Pump after maintenance for adjustments.
1.2 This procedure is applicable in any Mode.
2.0 PREREQUISITES 2.1 IDENTIFY sections of this procedure that are NOT to be performed with "N/A".
/1
-2.2 REVIEW Components "Off Normal and Off-Normal Tagged" List(s) for system and support system(s) associated with evolution to be performed in this procedure.
/5;e--2.3 IF aligning Service Water to supply AFW System, THEN OBTAIN EDO/OS permission for aligning Service Water to supply AFW System.
2.4 IF aligning Service Water to supply AFW System per EOP-FRHS-1, AND AFW pumps are NOT available, THEN ENSURE Steam Generator pressure is less than Service Water Header pressure.
Fýý -2.5 IF restoring AFW suction to normal alignment (Section 5.9) following Demin Water to AFW alignment, THEN ENSURE that Demin Water to AFW alignment is not required for Unit I AFW suction.
tý&
2.6 IF performing slow start of the Turbine-Driven AFW Pump, THEN ENSURE personnel from Mechanical Maintenance/I&C are available to observe slow start for proper governor operation.
Page 3 of 78 Salem 2 Rev. 21
£-',
ON-TE-SPOT CHANGES MUST KE ATTACHED FOR :ELZ 7j2
- O015C, S.OP-SO.AF-0001(Q)
IF supplying the AFW System via the AFWST, THEN:
2q-2.7.1
/Q 2.7.2
/-2.8 Chemistry Department is operating the AFWST nitrogen blanket IAW SC.CH-TI.ZZ-0123(Q), Chemistry Shift Turnover.
Chemistry Department is controlling the nitrogen blanket for the AFWST IAW SC.CH-TI.NT-0861(Q), AFST Nitrogen Purge Rig Operation.
IF preparing to drain the AFWST, THEN:
/Z 2.8.1
/_ý4 2.8.2 REVIEW Technical Specification 3.7.1.3 for applicability.
ENSURE Chemistry Department available to support draining.
3.0 PRECAUTIONS AND LIMITATIONS 3.1 Procedure Use and adherence policy as found in NC.NA-AP.ZZ-0001(Q). Nuclear Procedure System, is applicable to this procedure.
3.2 Multiple starts of Motor-Driven AFW Pumps may result in deterioration of pump motor windings. SC.OP-DD.ZZ-0003(Z), Large Motor Starting Criteria, contains starting restrictions for operation of Motor-Driven AFW Pumps.
3.3 Maximum permissible winding temperature is 266°F for 21 and 22 AFW Pumps. The normal operating winding temperature (fully loaded) is 230°F for 21 AFW Pump, and 209'F for 22 AFW Pump.
3.4 AFW Pumps must be run for a minimum of 5 minutes following the completion of chemical addition to flush the lines clear of residual chemicals.
(PR990526150) 3.5 Operation of AFW Pumps low suction pressure trip circuit is dictated by high wind and flooding conditions IAW S2.OP-AB.ZZ-0001(Q), Adverse Environmental Conditions.
[C03231 3.6 Coordination between Unit 2 and Unit 1 is required for placing AFW alternate suction piping in service and restoring to normal alignment.
3.7 DO NOT Trip Turbine-Driven AFW Pump with local trip switch unless the Local/Remote switch is in the Local position. This will prevent damage to the SSPS test curcuit.
3.8 Leaving local CMC switch in TRIP will damage trip solenoid control coil that would render all trip capability inoperable except Hand Trip Lever and Emergency Trip Lever.
3.9 Minimum allowable AFWST level during Modes 1, 2, and 3 is 200,000 gallons (91.09%) (TS 3.7.1.3).
Page 4 of 78 b42.7 Salem 2 Rev. 21
LL A-'
VE ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD USE s2.oP-so.AF-0001(Q) 3.10 Aligning Fresh Water and Fire Protection Water to AFW System renders one Fire Protection System inoperable.
3.11 Continuously monitor AFWST level during fills to prevent overflow.
3.12 Both steam supplies to 23 AFW Pump must be OPERABLE to consider 23 AFW Pump OPERABLE IAW Technical Specification 3.7.1.2.
3.13 An unavailable motor-driven AFW Pump must have its 125VDC control power energized prior to selecting PRESSURE OVERRIDE DEFEAT in Step 5.2.3, 5.6.3.
This allows the associated AF21 valve to be controlled from the Control Room console bezel.
3.14 When operating the Turbine-Driven AFW Pump knurled knob, DO NOT apply excessive force so as to move the knob past the minimum and maximum stops.
Applying excessive force may loosen knob, causing a loss of local control and damage to governor internals. Should the knurled knob loosen, contact maintenance to tighten knob. Should the internals of the governor move, as determined by maintenance, the governor must be removed and sent out for repair.
3.15 22 Blowdown tank will spill over into 23 Aux Feed Pump Turbine Steam Header Drain Line at =91.6% (66") level. Line will fill with water and present backpressure problems for drains.
3.16 The following are applicable when performing section 5.11, Slow Start Turbine-Driven AFW Pump:
3.16.1 When Main Steam Isolation Valves are closed, varying the steam flow rate to No. 23 AF Turbine has the potential to cause a Safety Injection actuation due to Steam Line Differential Pressure.
3.16.2 IF Unit 2 is in Mode 1 or 2, THEN the time that 23 AF Pump watertight door is open should be minimized AND the NEO is to inform the NCO of door opening and closing times for recording IAW SC.OP-AP.ZZ-0004(Q), Cyclic Data Monitoring Program.
3.16.3 The Governor Oil Reservoir level is to remain observable in the sightglass during 23 AF Pump operation.
3.16.4 Turbine speed is not to exceed 4000 rpm under any circumstances. If a control problem arises, abnormal noises are heard, or excessive vibration occurs, the operator is to trip the turbine with the 2MS52 Hand Trip Lever.
3.16.5 Technical Specification 3.7.1.2 is applicable when 2MS52, 23 AF PMP TURB TRIP V is tripped.
3.16.6 IF any turbine bearing temperature exceeds 165 0F, THEN 23 AF Turbine should be immediately tripped.
3.16.7 DO NOT operate the Turbine-Driven AFW Pump if suction pressure is
< 8.0 psig.
Page 5 of 78 Salem 2 Rev. 21
L ACT V.
ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD USE S.OP-SO.AF-001(Q) 4.0 EQUIPMENT/MATERIAL REQUIRED 4.1 Additional Tools and Equipment:
Pipe wrench for removal and installation of pipe caps (Section 5.1)
Wrenches for Fire Water to AFW Spool Piece installation and removal (Sections 5.8, 5.9)
JA Master Key for locked valves and access to 2MS52 (Sections 5.3, 5.4, 5.7, 5.8, 5.9)
Ladder for access to AFW alternate suction line drain valves on Elev. 64' Aux Bldg (Sections 5.8, 5.9)
Ladder for access to AFW alternate suction line drain valves in Elev. 64' Switchgear Rooms (Sections 5.8, 5.9)
Aux Feedwater Spool Piece installation toolbox for installation and removal of Service Water to AFW Spool Piece (Sections 5.8, 5.9)
Hose or sleeving for draining AFW alternate suction line (Section 5.9)
+
Locking tab cutting device for locked valves not secured with JA locks.
Page 6 of 78 Salem 2 Rev. 21
LL ATV-E ON-THE-SPOT CHANGES MUST BE ATTACHED FOR F1ELD USE D021,15 S2.OP-SO.AF-0001(Q) 5.8 Alternate Water Source Alignments NOTE Preferred sequence of alternate water sources in event AFWST is NOT available is as follows:
- 1.
Demin Water Storage Tanks
- 2.
Fresh Water and Fire Protection Water Storage Tanks
- 3.
Service Water When either Demin Water Storage Tanks or Fresh Water and Fire Protection Water Storage Tanks are relied upon as operable AFW supply, performance of S2.OP-ST.AF-001 1 (Q), Auxiliary Feed Water Alternate Suction Source Verification Modes 1-3, is required at least once every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
/**
- 8. 1 ENSURE all AFW Pumps are out-of-service.
2_-5.8.2 IF Demin Water Storage Tank is to be aligned to AFW, THEN:
AJ{/
A. IF the in-service Demin Storage Tank level is < 38% (200,000 gallons),
THEN ENTER TSAS 3.7.1.3.b.
B.
Direct NEO to ALIGN Demain Water to AFW IAW Attachment 4.
C.
IF AUXILIARY FEED PUMP BACKUP SUCTION VALVES are to be operated locally, THEN:
- 1.
UNJACK the following valves from closed position, AND REMOVE jacking wheel:
./V
- a.
21AF52
/4
- b.
22AF52
- c.
23AF52 4A)4
- 2.
INSERT jacking wheel on other side of jacking mechanism, AND JACK OPEN the following valves:
- a.
21AF52
- b.
22AF52 c(t 23AF52 (step continued on next page)
Rev. 21 Page 38 of 78 Saem 2
L.AT, O-TH-E-SPOT CHANGES MUST BE ATTACHED FOR F:EL.
J 1 'D 1 S2.OP-SO.AF-0001(Q) 5.8.2 (continued)
D.
IF AUXILIARY FEED PUMP BACKUP SUCTION VALVES are to be operated from the Control Room, THEN:
- 1.
OPEN air supplies to the following:
- a.
21AF52 (Inside 21 Aux Feedwater Panel 205)
- b.
22AF52 (Inside 22 Aux Feedwater Panel 206)
- c.
23AF52 (Inside 23 Aux Feedwater Panel 207)
- 2.
UNJACK the following valves locally:
- a.
21AF52
- b.
22AF52
- c.
23AF52
- 3.
OPEN the following valves from the Control Room:
- a.
21AF52
- b.
22AF52
- c.
23AF52 E.
Direct NEO to CLOSE the following AUX FEED PUMP SUCTION VALVEs:
S1.
21AF3
- 2.
22AF3
- 3.
23AF3 F.
IF required to feed Steam Generators from Demin Water Storage Tank, THEN:
- 1.
NOTIFY Chemistry that Steam Generators are to be fed from Demin Water Storage Tank.
- 2.
START AFW Pump(s) IAW section(s) of this procedure.
G.
UPDATE WCM to reflect off-normal valve positions.
H.
INITIATE performance of S2.OP-ST.AF-0011(Q)
AND RECORD time and date of initiation IAW SH.OP-AP.ZZ-0108(Q), Operability Assessment and Equipment Control Program.
Page 39 of 78 Salem 2 Rev. 21
Li AC -vE ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD USE 02 10 !51 S2.OP-SO.AF-0001(Q)
CAUTION Aligning Fresh Water and Fire Protection Water to Auxiliary Feedwater System renders one Fire Protection System inoperable.
5.8.3 IF Fresh Water and Fire Protection Water Storage Tank is to be aligned to AFW, THEN:
A. IF #1 Fresh Water and Fire Protection Water Storage Tank level is
<54% (200,000 gallons),
THEN ENTER TSAS 3.7.1.3.b.
B.
C/T 1NA16847, #1 FIRE PUMP CONTROLLER MODE SELECTOR SWITCH, in the OFF position for OS/CRS to prevent a pump start with the suction valve closed.
C.
Direct NEO to ALIGN #1 Fresh Water and Fire Protection Water Storage Tank to AFW IAW Attachment 5.
D. IF AUXILIARY FEED PUMP BACKUP SUCTION VALVES are to be operated locally, THEN:
- 1.
UNJACK the following valves from closed position, AND REMOVE jacking wheel:
- a.
21AF52
- b.
22AF52
- c.
23AF52
- 2.
INSERT jacking wheel on other side of jacking mechanism, AND JACK OPEN the following valves:
- a.
21AF52
- b.
22AF52
- c.
23AF52 (step continued on next page)
Page 40 of 78 Salem 2 Rev. 21
A.
Acv 0\\--1E-SPO-CHANGES MUST BE ATTACHED -FOR F
UEL S
U j3021015 S.OP-SO.AF-000I(Q) 5.8.3 (continued)
E.
IF AUXILIARY FEED PUMP BACKUP SUCTION VALVES are to be operated from the Control Room, THEN:
- 1.
OPEN air supplies to the following:
- a.
21AF52 (Inside 21 Aux Feedwater Panel 205)
- b.
22AF52 (Inside 22 Aux Feedwater Panel 206)
- c.
23AF52 (Inside 23 Aux Feedwater Panel 207)
- 2.
UNJACK the following valves locally:
- a.
21AF52
- b.
22AF52
- c.
23AF52
- 3.
OPEN the following valves from the Control Room:
- a.
21AF52
- b.
22AF52
- c.
23AF52 F.
Direct NEO to CLOSE the following AUX FEED PUMP SUCTION VALVEs:
- 1.
21AF3
- 2.
22AF3
- 3.
23AF3 G. IF required to feed Steam Generators from Fresh Water and Fire Protection Water Storage Tank, THEN:
- 1.
START AFW Pump(s) IAW section(s) of this procedure.
- 2.
NOTIFY Chemistry that Steam Generators are being fed Fresh Water and Fire Protection Water Tanks.
H. UPDATE WCM to reflect off-normal valve positions.
I.
INITIATE performance of S2.OP-ST.AF-0011(Q),
AND RECORD time and date of initiation IAW SH.OP-AP.ZZ-0108(Q), Operabioity Assessment and Equipment Control Program.
Page 41 of 78 Salem 2 Rev. 21 from
,LL ACTIVE ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD USE
.0021015 s2.OP-SO.AF-0001(Q)
CAUTION EDO/OS permission is required for aligning Service Water to supply AFW System.
5.8.4 IF all other feedwater sources are depleted or unavailable, THEN ALIGN Service Water to AFW, as follows:
A.
OBTAIN EDO/OS permission to align Service Water to supply AFW System.
B.
Direct NEO to ALIGN Service Water to AFW JAW Attachment 6.
C.
IF required to feed Steam Generators from Service Water, THEN:
- 1.
IF 21 - 23AF3, AUX FEED PUMP SUCTION VALVEs, are open, THEN direct NEO to CLOSE the following AUX FEED PUMP SUCTION VALVEs:
- a.
21AF3
- b.
22AF3
- c.
23AF3
- 2.
START AFW Pump(s) lAW appropriate Subsection(s) of this procedure.
- 3.
NOTIFY Chemistry that Steam Generators are being fed from Service Water.
D. UPDATE WCM to reflect off-normal valve positions.
Page 42 of 78 Salem 2 Rev. 21
"LL ACTIVE ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD USE 1 02 1015 s 2.OP-SO.AF-0001(Q)
ATTACHMENT 4 (Page 1 of 2)
DEMIN WATER TO AFW ALIGNMENT NOTE When AFW Alternate Suction piping filled, inspections of Unit 1 and Unit 2 Elev. 64' Switchgear Rooms are required at least once per shift with results recorded in Control Room Narrative Log.
1.0 CLOSE the following ALTERNATE SUCTION PIPING DRAIN VALVEs:
2AF94 (Elev. 64' Switchgear Room) 1AF94 (Elev. 64' Switchgear Room) 1AF142 (Elev. 64' Aux Bldg, near 1 Waste Monitor Hold-Up Tank Pump) 2AF95 (Elev. 64' Aux Bldg corridor) 1AF95 (Elev. 64' Aux Bldg corridor) 2.0 OPEN 1AF51, AF BU TIE TO ALT WT SUP VALVE (Elev. 84', outside Swgr Rms).
3.0 Slowly OPEN 1DM254, AFW PUMP DM WTR SUP LINE FILL VALVE, to fill AFW Pump alternate suction piping (Elev. 88' TGA, above 15 TGA Sump Pump).
Page 65 of 78 Salem 2 Rev. 21
-L ACTIVE ON-THE-SPOT CHANGES MUST BE ATTACHED" FOR FIELD USE
)0211015 S.OP-SO.AF-0001(Q)
ATTACHMENT 4 (Page 2 of 2)
DEMIN WATER TO AFW ALIGNMENT 4.0 IF any AUTO VENT valve fails to CLOSE after all air is expelled from alternate suction piping, THEN CLOSE associated AUTO VENT ISOL VALVE:
[C0455]
AUTO VENT
(
M)
AUTO VENT ISOL VALVE LOCATION 1DM256 1DM255 El. 88' TGA 1AF137 1AF136 El. 84', outside Switchgear rooms 1AF139 1AF138 El. 84' Aux Bldg, 11 CC Hx room 11AF141 llAF140 El. 84' Aux Bldg, 11 AFW Pump alt. suction line 12AF141 12AF140 El. 84' Aux Bldg, 12 AFW Pump alt. suction line 13AF141 13AF140 El. 84' Aux Bldg, 13 AFW Pump alt. suction line 2AF139 2AF138 El. 84' Aux Bldg, 21 CC Hx room 21AF141 21AF140 El. 84' Aux Bldg, 21 AFW Pump alt. suction line 22AF141 22AF140 El. 84' Aux Bldg, 22 AFW Pump alt. suction line 23AF141 23AF140 El. 84' Aux Bldg, 23 AFW Pump alt. suction line 5.0 WHEN suction piping is filled, THEN OPEN 1DM216, AF PUMP DM WTR SUP VALVE (Elev. 88' TGA).
6.0 CLOSE 1DM254, AFW PUMP DM WTR SUP LINE FILL VALVE 7.0 NOTIFY NCO that Demin Water is aligned to AFW alternate suction piping.
Page 66 of 78 Salem 2 Rev-21
NC.TQ-WB.ZZ-031 0(Z)
STATION:
SYSTEM:
TASK:
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM ESFAS (013)
De-energize SEC's lAW LOPA-1 TASK NUMBER:
JPM NUMBER:
ALTERNATE PATH:
APPLICABILITY:
EO fl-1150140501 2002 GOLF NRC SRO P2 ROrFl KIA NUMBER:
IMPORTANCE FACTOR:
STA =jj SRO EZZI 2.1.30 3.9 RO EVALUATION SETTING/METHOD:
Plant/Simulate
REFERENCES:
1-EOP-LOPA-1, Rev. 22 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
10 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
ARGAININP UNIT REPRESENT TIVE A
S-TRAINING SUPERVISOR or designee OPERATIONS 9eNAGER or desi ee CAUTION:
No plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: E SAT R UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
3.4 SRO Nuclear Common Page 1 of 4 Rev. 0 I
4AIýv
OPERATOR TRAINING PROGRA JOB PERFORMANCE MEASURE NAME:
DATE:
NC.TQ-WB.ZZ-0310(Z)
SYSTEM:
TASK:
ESFAS (013)
De-energize SEC's lAW LOPA-1 TASK NUMBER:
1150140501 INITIAL CONDITIONS:
- 1.
A station blackout has occurred.
- 2.
The operating crew has implemented 1-EOP-LOPA-1.
SIMULATOR SETUP:
N/A INITIATING CUE:
You have been dispatched from the WCC to de-energize all Unit 1 SEC's by opening 1AVIB24, 1BVIB27, and 1CVIB9.
Nuclear Common Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Page 2 of 4 Rev. 0
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
SYSTEM:
ESFAS (013)
TASK:
De-energize SEC's lAW LOPA-1 STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
START TIME:
1 Provide Candidate with tearoff sheet.
NOTE: Breakers can be operated in any sequence.
2 1AVIB24, 1A SEC Locates 1AVIB24 (1A VIB Bus Panel, Relay Room) and points out OPEN position.
3 1BVIB27, 1B SEC Locates 1BVIB27 (1B VIB Bus Panel, Relay Room) and points out OPEN position.
4 1CVIB9, 1C SEC Locates 1CVIB9 (1C VIB Bus Panel, Relay Room) and points out OPEN position.
5 Makes report to control room Locates nearest phone or page STOP TIME:
Terminating Cue: Acknowledge report and state "this JPM is complete".
Nuclear Common Page 3 of 4 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
INITIAL CONDITIONS:
- 1.
A station blackout has occurred.
- 2.
The operating crew has implemented 1-EOP-LOPA-1.
INITIATING CUE:
You have been dispatched from the WCC to de-energize all Unit 1 SEC's by opening 1AVIB24, 1BVIB27, and 1CVIB9.
Nuclear Common Page 4 of 4
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SALEM STATION:
SYSTEM:
Pressurizer Pressure (010)
TASK:
TASK NUMBER:
JPM NUMBER:
Take local control of the PZR backup heaters 1140130401 2002 GOLF NRC SROI P3/SROU P2 ALTERNATE PATH:
APPLICABILITY:
EO-K/A NUMBER:
IMPORTANCE FACTOR:
ROW STA =
SRO Eli!
2.1.30 3.9 3.4 RO SRO EVALUATION SETTING/METHOD:
Plant/Simulate
REFERENCES:
S1.OP-AB.CR-0001, Rev. 7 TOOLS AND EQUIPMENT:
NONE VALIDATED JPM COMPLETION TIME:
15 Minutes TIME PERIOD IDENTIFIED FOR TIME CRITICAL STEPS:
N/A APPROVAL:
or designee or designee CAUTION:
N~o plant equipment shall be operated during the performance of a JPM without the following:
- 1. Permission from the OS or Unit CRS;
- 2. Direct oversight by a qualified individual (determined by the individual granting permission based on plant conditions).
- 3. Verification of the "as left" condition by a qualified individual.
Rev. 0 ACTUAL JPM COMPLETION TIME:
Minutes ACTUAL TIME CRITICAL COMPLETION:
Minutes JPM PERFORMED BY:
GRADE: rISAT []
UNSAT REASON, IF UNSATISFACTORY:
EVALUATOR'S SIGNATURE:
DATE:
FATIVE
/7 Page 1 of 5 Nuclear Common
NC.TQ-WB.ZZ-031 0(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE NAME:
DATE:
SYSTEM:
TASK:
Pressurizer Pressure (010)
Take local control of the PZR backup heaters.
TASK NUMBER:
1140130401 INITIAL CONDITIONS:
- 1.
The Control Rooms have been evacuated in accordance with S1 and S2.OP-AB.CR-0001.
- 2.
The Hot Shutdown Panels are manned.
- 3.
Remote panel operators are being dispatched.
- 4.
All pressurizer pressure controls were in MANUAL when the Control Room was evacuated SIMULATOR SETUP:
N/A INITIATING CUE:
You have been assigned to operate the Unit 1 pressurizer heaters in accordance with S1.OP-AB.CR-0001 (AB.CR-1), Attachment 12. Report to the local pressurizer heater control station and simulate establishing communications.
Nuclear Common Successful Completion Criteria:
- 1. All critical steps completed.
- 2. All sequential steps completed in order.
- 3. All time-critical steps completed within allotted time.
- 4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.
Page 2 of 5 Rev. 0
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
Pressurizer Pressure (010)
Take local control of the PZR backup heaters.
Nuclear Common TASK:
NC.TQ-WB.ZZ-0310(Z)
NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
START TIME:
Provide a copy of Si.OP-AB.CR-0001, 2.
1 Candidate proceeds to the Unit 1 Electrical Penetration Area, El. 78.
(1.0)
Establish communications with the Hot Locates/points out headset and jack.
Shutdown Panel (HSD) Operator.
(2.0)
Locally close the following PZR Heater supply breakers:
1EX1EPX, 1EP 480V PZR HTR BUS Locates 1EX1EPX, Ven os,.4 MN BKR 1GX1EP1GP, 1GP 480V PZR HTR Locates 1GX1EP1GP,r,,C 1 -'foseJ.
BUS B/U SECT MN BKR Page 3 of 5 Rev. 0
NC.TQ-WB.ZZ-0310(Z)
OPERATOR TRAINING PROGRAM JOB PERFORMANCE MEASURE SYSTEM:
Pressurizer Pressure (010)
Take local control of the PZR backup heaters.
NAME:
DATE:
STEP STEP COMMENTS NO.
(*Denotes a Critical Step)
STANDARD EVAL (Required for
(#Denotes a Sequential Step)
S/U UNSAT evaluation)
(3.0)
Determine if PZR Pressure is controlling Simulates communications with HSD pressure at 2235 psig in AUTO by Operator.
communicating with HSD Panel Operator.
(3.1)
If Pressurizer pressure is not Locates the LOCAL and MANUAL control controlling in AUTO, then manually stations (There is one station for LOCAL control Pressurizer pressure at 2200 control and one station for MANUAL control psig to 2250 psig by taking for 11 Backup heaters. There is one LOCAL/MANUAL control and station for LOCAL control and one station operating Pressurizer heater breakers for MANUAL control for 12 Backup heaters.
as required to stabilize pressure.
Both are attached on the upper right end of the heater busses. Candidate takes manual control by selecting LOCAL/REMOTE switches to LOCAL for 11 and 12 Backup heaters.
(3.2)
When directed by the HSD Panel CUE: An RCS cooldown is in progress, de Operator, reduce pressure by energize 11 Backup heaters.
deenergizing Pressurizer heaters during RCS cooldown.
Candidate locates MANUAL station on 1 GP Heater bus and selects OFF for 11 Backup heaters.
CUE: The heaters are off.
STOP TIME:
Terminating Cue: Once heater breakers are off then state "this JPM is complete".
Nuclear Common TASK:
Page 4 of 5 Rev. 0
NC.TQ-WB.ZZ-031 0(Z)
INITIAL CONDITIONS:
- 1.
The Control Rooms have been evacuated in accordance with S1 and S2.OP AB.CR-0001.
- 2.
The Hot Shutdown Panels are manned.
- 3.
Remote panel operators are being dispatched.
- 4.
All pressurizer pressure controls were in MANUAL when the Control Room was evacuated INITIATING CUE:
You have been assigned to operate the Unit 1 pressurizer heaters in accordance with S1.OP-AB.CR-0001 (AB.CR-1), Attachment 12. Report to the local pressurizer heater control station and simulate establishing communications.
Nuclear Common Page 5 of 5
ALL ACTIVE ON-THE-SPOT CHANGES MUST BE ATTACHED FOR FIELD USE 20020922 Sl.OP-AB.CR-0001(Q)
ATTACHMENT 12 (Page 1 of 1)
LOCAL PRESSURIZER HEATER CONTROL (Electrical Penetration Area elevation 78', Panels 1GP and 1EP)
CA AIJ 0 (M 1.0 ESTABLISH communications with the Hot Shutdown Panel Operator.
CA0tP/4-A___ 2.0 Locally CLOSE Pressurizer Heater supply breakers.
1EXlEPX, 1EP 480V PZR HTR BUS MN BKR 1GXIEP1GP, IGP 480V PZR HTR BUS BIU SECT MN BKR 3.0 DETERMINE if Pressurizer Pressure is controlling pressure at 2235 psig in Automatic by communicating with Hot Shutdown Panel Operator.
O4*IP Q4 7,6 3.1 IF Pressurizer pressure is not controlling in automatic, THEN MANUALLY control Pressurizer pressure at 2200 psig to 2250 psig by taking LOCAIJMANUAL control and operating pressurizer heater breakers as required to stabilize pressure.
When directed by Hot Shutdown Panel Operator, REDUCE pressure by deenergizing Pressurizer Heaters during RCS cooldown.
4.0 MAINTAIN communications with the Hot Shutdown Panel Operator until access is restored to Control Room.
Page 65 of 83 NOTE
+
All operations at local control stations are directed by the Hot Shutdown Panel Operator.
+
The following indications and controls are available for local operation:
Pressurizer Heater Backup Group LOCAL/REMOTE Switch Pressurizer Heater Backup Group ON/OFF Switches Pressurizer Heater Backup Group power supply breakers
+
Pressurizer Heater AUTO cutout at 17% level is defeated only when the control power is removed from the breaker and the breaker is operated with the Close/Trip buttons located on the breaker.
OUOINT'g A__I_
3.2 Sallem 1 Rev. 7