-J TABLE B-I MINIMUM STAFFING REQUIREMENTS (Including Capability for Additional Staffing)
MAJOR FUNCTIONAL AREA Plant Operations POSITION/TITLE or EXPERTISE Shift Manager (SRO) 4 Control Room Supervisor (SRO)
Control Room Operators Auxiliary Operators Shift Technical Advisor (Shift Engineer)7 Waste Control Operator (Radwaste)
ON-SHIFT' U-i U-2 2 2 1
AVAILABLE3 IN 60 N4N 1
2 2
2 I
AVAILABLE3 IN 90 MIN I
Emergency Direction and Control (Emer. Coord.)
Notification/
Communication 2
Communicator Control RoomITSC/EOF Communications Personnel Radiological Accident Assessment and Support of Operational Accident Assessment, and Protective Actions (in plant) aJ (0
Dose Assessment Supervisor Nuclear Chemists (Offsite Dose Projections)
Health Physics Technician' (In-Plant Surveys)
Health Physics Technician (Onsite Out-of-Plant Surveys)
Health Physics Technicians (Protective Actions-In Plant)
Health Physics Technicians (Offsite Surveys) 110 mI 1
1 1
1 I
32 32 2
2 Nuclear Chemistsi' I
I 14 14 2
2 1
1 I
-4 m
2 2
S..
- 11 C
Iii
'Si I
Chemistry/Radiochemistry
C:,
7U TABLE B-I (Continued)
GROUP Repair and Corrective Actions Plant System Engineering POSITION/TITLE Electrical Maintenance I&C Technician Mechanic Core/Thermal Hydraulics Electrical Engineer Mechanical Engineer ON-SHIFT U-1 U-2 32 32 32 AVAILABLE1 IN 60 MIN AVAILABLE3 IN 90 MIN 16 32 2
1 1 1 Unit 1 SAR, Sec. 9.8 Unit 2 SAR, App. 9A Rescue Operations and First-Aid Site Access Control and Personnel Accountability 22 Security Personnel Local Support (30 Minute Response)
Local Support (30 Minute Response)
All per Security Plan Firefighting
-I 0
U, 0
0 a,
a, "3
I
-4 TABLE B-I (Continued)
"e These ERO positions may be vacant for not more than two hours, in order to provide for unexpected absences, provided immediate action is taken to rill the required position.
2 May be provided by shift personnel assigned other functions.
3 Once notified, emergency responders are to report to their assigned facility as soon as possible and without delay.
4 The Shift Manager initially assumes the responsibility for Emergency Direction and Control, then is relieved by the TSC Director or EOF Director.
3 Electrical Maintenance personnel.
6 I&C Maintenance personnel.
7 The duties of the Shift Technical Advisor are performed by the Shift Engineer of the affected unit.
8 The duties of the Communicator are performed by the Shift Engineer of the unaffected unit.
9 STA duties encompass the Core/Thermal Hydraulics function.
10 There are two Nuclear Chemists on shift qualified to perform offsite dose projections and chemistry/radiochemistry functions for either unit.
"1 Health Physics Technicians are qualified to perform Protective Actions In-Plant and In-Plant Surveys.