ML021430464 From:
Peter Tam To:
INTernet:David.distel@exeloncorp.com; INTernet:george.rombold@exeloncorp.com; internet:paul.czaya@exelon.com Date:
5/23/02 11:42AM
Subject:
Request telecon re. 2 proposed amendments (TAC MB2890 and MB2893)
David, Paul:
Our review of your Change Requests 292 and 298 is ongoing. We need to discuss with you the following issues. Can we have a telecon next week with our reviewer, Zena Abdullahi?
This e-mail does not state an NRC staff position, and does not formally request information. The disposition of the issues will be discussed in the telecon.
Both proposed amendments refer to SRM channels as opposed to SRMs or SRM detectors. In some cases, you changed the term "SRMs" to "SRM channels or SRM channel detectors."
Is there a specific reason for this? If there is one detector per SRM channel, why use the term "channel" instead of SRM? How many SRM system channels are available? How many channels can be bypassed per time?
Change Request 292 The second paragraph of page 2 of 4 states that when fuel is shuffled in the core, two locations are involved in the core alteration. In this case, how many SRMs need to be operable in order to meet the requirement - one SRM in the quadrant, where core alterations are being performed and one SRM in the adjacent quadrant? Can you explain why the TS requires a minimum of two SRMs to be operable during core alteration - at least for fuel shuffling?
TS Change 298 Explain why the proposed change is necessary. Are the refueling interlocks unreliable and become inoperable often? What are the reliability records of the refueling equipment interlocks.
The staff is concerned that the proposed alternative would be used to intentionally declare the interlocks inoperable. How about some specific statements in the Bases that would explicitly state the purpose of the alternative method. State that the first SR will be performed before starting the fuel movement. Specify any other procedures that require the SR to be performed before performing core alteration.
Peter S. Tam, Senior Project Manager Project Directorate I-1 Division of Licensing Project Management Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451 cc. G. Hatchett; S. Mazumdar; Zena Abdullahi Mail Envelope Properties (3CED0DFF.501 : 10 : 20510)
Subject:
Request telecon re. 2 proposed amendments (TAC MB2890 and MB2893)
Creation Date:
5/23/02 11:42AM From:
Peter Tam Created By:
PST@nrc.gov Recipients Action Date & Time David Transferred 05/23/02 11:43AM distel (INTernet:David.distel@exeloncorp.
george Transferred 05/23/02 11:43AM rombold (INTernet:george.rombold@exelonco paul Transferred 05/23/02 11:43AM czaya (internet:paul.czaya@exelon.com) nrc.gov owf2_po.OWFN_DO Delivered 05/23/02 11:43AM GXH CC (Gregory Hatchett)
Opened 05/23/02 11:48AM SXM3 CC (Subinoy Mazumdar)
Opened 05/23/02 01:15PM ZXA CC (Zena Abdullahi)
Opened 05/23/02 12:07PM Post Office Delivered Route David INTernet:exeloncorp.
com george INTernet:exeloncorp.
com paul internet:exeloncorp.c om owf2_po.OWFN_DO 05/23/02 11:43AM nrc.gov Files Size Date & Time MESSAGE 3712 05/23/02 11:42AM Options Auto Delete:
No Expiration Date:
None Notify Recipients:
Yes Priority:
Standard Reply Requested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard To Be Delivered:
Immediate Status Tracking:
Delivered & Opened