From:

Peter Tam To:

Gregory Hatchett; INTernet:David.distel@exeloncorp.com; INTernet:John.Hufnagel@exeloncorp.com Date:

8/13/02 10:00AM

Subject:

Oyster Creek refueling interlock amendment (TAC MB2893)

John:

Our reviewer, Greg Hatchett, reviewed your 6/27/02 supplement re. compensatory mesaures regarding the refueling interlocks. Please call me to set up a conference call to clarify the following:

- To prevent criticality during refueling, the refueling interlocks ensure that fuel asseblies are not loaded with any control rod withdrawn. To prevent these conditions from developing, the all-rods-in, the refueling platform position, the refueling platform fuel grapple fuel loaded, the refueling platform trolley frame mounted hoist fuel loaded, the refueling platform monorail mounted hoist fuel loaded, the refueling platform fuel grapple fully retracted position, and the service platform hoist fuel loaded inputs are required to be operable. Are these inputs combined in logic circuits which provide refueling equipment or control rod blocks to prevent operations that could result in criticality during refueling operations? How does an inoperable ARI permissive effect the above?

- Does an inoperable ARI result in not meeting TS 3.9.C? If it does why? If it does not, why not?

- If TS 3.9.C is not met due to an inoperable ARI permissive that combines in the logic for the refueling interlocks, when will the ARI permissive be restored allowing the LCO to be met?

- In the 6/27/02 supplement, you indicated that you would complete the initial testing of the interlock prior to in-vessel fuel movement. The staff finds that refuel interlocks should be tested every 7 days to demonstrate that the interlock will function properly when simulated or actual signal indicative of a required condition is injected into the logic. What is Oyster Creeks SR frequency for the refueling interlocks?

This e-mail aims solely to prepare you for the requested conference call. It does not formally request additional information, nor does it convey a formal NRC staff position.

The above issues will be dispositioned in the conference call.

Peter S. Tam, Senior Project Manager Project Directorate I-1 Division of Licensing Project Management Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451 Mail Envelope Properties (3D591107.B79 : 10 : 20510)

Subject:

Oyster Creek refueling interlock amendment (TAC MB2893)

Creation Date:

8/13/02 10:00AM From:

Peter Tam Created By:

PST@nrc.gov Recipients Action Date & Time David Transferred 08/13/02 10:00AM distel (INTernet:David.distel@exeloncorp.

John Transferred 08/13/02 10:00AM Hufnagel (INTernet:John.Hufnagel@exelonco nrc.gov owf2_po.OWFN_DO Delivered 08/13/02 10:00AM GXH (Gregory Hatchett)

Opened 08/13/02 10:29AM Post Office Delivered Route David INTernet:exeloncorp.

com John INTernet:exeloncorp.

com owf2_po.OWFN_DO 08/13/02 10:00AM nrc.gov Files Size Date & Time MESSAGE 3384 08/13/02 10:00AM Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard Reply Requested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened