{{#Wiki_filter:North Atlantic Energy Service Corporation North P.O. Box 300 Seabrook, NH 03874 Atlantic (603) 474-9521 The Northeast Utilities System April 29, 2002 Docket No. 50-443 NYN-02042 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001 Seabrook Station 2001 Annual Radiological Environmental Operating Report North Atlantic Energy Service Corporation (North Atlantic) hereby submits the 2001 Annual Radiological Environmental Operating Report for Seabrook Station. This report summarizes the implementation of North Atlantic's Radiological Environmental Monitoring Program (REMP). to the enclosure is the complete data set for the REMP samples. This report is being submitted pursuant to the requirements of 10CFR 50.36a(a)(2) and Seabrook Station Technical Specification 6.8.1.3. Should you require further information regarding this matter, please contact William T. Cash, Manager - Health Physics Department, at (603) 773-7315. Very truly yours, NORTH ATLANTIC ENERGY SERVICE CORP.
- Regulatory Programs cc: without enclosure I H. J. Miller, NRC Region I Administrator R. D. Starkey, NRC Project Manager, Project Directorate 1-2 G. T. Dentel, NRC Senior Resident Inspector I10,5
ENCLOSURE TO NYN-02042 SEABROOK STATION ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT For the Period January - December 2001 April 2002 Prepared By: Jerry Kwasnik, Ph.D. North Atlantic Energy Service Corporation Health Physics Department Seabrook Station and Duke Engineering & Services Environmental Engineering Department Marlborough, Massachusetts 01752
TABLE OF CONTENTS Section Page EXECUTIVE
SUMMARY
ii LIST OF TABLES iii LIST OF FIGURES iv
1.0 INTRODUCTION
............................................. 1 2.0 ENVIRONMENTAL MONITORING PROGRAM ........................ 2 3.0
SUMMARY
OF RADIOLOGICAL ENVIRONMENTAL DATA ................ 13 A. Air Particulate ...................................... 14 B. Charcoal Filter ...................................... 22 C. Milk ................................................. 24 D. Surface Water ........................................ 31 E. Ground Water ......................................... 34 F. Sediment ............................................. 39 G. Fish ................................................. 42 H. Lobsters ............................................. 45 I . Shellfish ............................................ 48 J . Irish Moss ........................................... 51 K. Food Crops ........................................... 54 L. Direct Radiation ..................................... 57 4.0 QUALITY ASSURANCE PROGRAM ............................... 78 5.0 LAND USE CENSUS ......................................... 87
6.0 REFERENCES
.............................................. 89 a
Executive Summary The Radiological Environmental Monitoring Program for Seabrook Station operated without interruption for the period of January through December 2001. This report describes the REMP program and its implementation as required by Technical Specifications as defined in the Technical Requirements Manual. It also contains analytical results, data evaluation, dose assessment, and data trends for each environmental sample media. Also included are the results of the Land Use Census, historical data, and the Duke Engineering and Services Environmental Laboratory (DESEL) performance in the Quality Assurance Intercomparison Program required by the Technical Requirements Manual. Samples collected as part of the radiological environmental program included air particulates, charcoal filters, milk, ground water, surface (sea) water, sediment, fish, lobsters, shellfish, algae, vegetation and direct radiation. Radiological analysis on each sample included determination for both gamma and/or beta radiation. Any variability observed in the data is based on natural variables that can influence background radiation. The radionuclides identified as naturally occurring are K-40, Be-7, Th-232 and its daughter products. Cesium-137 was detected in milk as the result of fallout from atmospheric nuclear weapons testing. The levels detected are similar to those levels measured during the preoperational phase of the monitoring program. There is a decreasing trend in the number of positive samples identified. This is due to the natural decay of the residual Cs-137. Condition Reports relating to the REMP were entered into the Station Corrective Action Program. Specific condition reports are discussed in the applicable report section. In 2001, the maximum whole body dose to the hypothetically exposed individual was 0.0198 millirem. This whole body dose is the sum of all the exposure pathways for liquid and gaseous effluents, plus the direct whole body dose from station operations. This total dose represents approximately 0.08% of the whole body dose limit for a member of the public as set forth in 40CFRl90. The complete calculational methodology is submitted to the NRC as part of the Annual Radioactive Effluent Release Report. The results of the 2001 Radiological Environmental Surveillance Program continues to clearly demonstrate that there is no significant short term or chronic long term radiological impact on the environment in the vicinity of Seabrook Station from plant operations. No abnormal radiological characteristics were identified or observed in the surrounding environs. Plant effluents contribute no measurable radiation exposure to the general public as confirmed and assessed by the REMP. Environmental radiation levels measured on site, at the site boundary and near the nearest resident are at background levels. This is consistent with previous data. As a result, no increasing or decreasing trend exists. ii
LIST OF TABLES Number Title Page 2.1 Radiological Environmental Monitoring Program 3 2.2 Radiological Environmental Monitoring Locations 4 3.1 Environmental TLD Measurements ................... 58 4.1 Summary of Process Control Analysis Results ... 81 4.2 Summary of DESEL/Analytics crosscheck Results.. 82 4.3 Summary of Blind Duplicate Samples Submitted . 85 4.4 Summary of Blind Duplicate Results ............... 86 5.1 Land Use Census Results ....................... 88 iii
LIST OF FIGURES Number Title Page 2.1 Radiological Environmental Monitoring Locations Within 4 Kilometers of Seabrook Station .................. 7 2.2 Radiological Environmental Monitoring Locations Between 4 Kilometers and 12 Kilometers from Seabrook Station ...................................... 8 2.3 Radiological Environmental Monitoring Locations Outside 12 Kilometers of Seabrook Station ................ 9 2.4 Direct Radiation Monitoring Locations Within 4 Kilometers of Seabrook Station ........................ 10 2.5 Direct Radiation Monitoring Locations between 4 Kilometers and 12 Kilometers from Seabrook Station.. 11 2.6 Direct Radiation Monitoring Locations Outside 12 Kilometers of Seabrook Station ......................... 12 3.1 Gross Beta Measurements of Air Particulate Filters ..... 15 3.1.1 Gross Beta Quarterly Averages 1986-99 (AP 01,02,03,06) 16 3.1.2 Gross Beta Quarterly Averages 1986-99 (AP 04,05,06) .... 17 3.1.3 Gross Beta Quarterly Averages 1986-99 (AP 07,08,06) .... 18 3.2 Gross Beta Quarterly Average Air Particulate Filters... 19 1994-2001 Indicators vs. Control 3.3 Cesium-137 in Milk (Stations TM-04, 09, 15, 16) ........... 25 3.3.1 Cesium-137 (Milk) Annual Average Concentrations 1986-2001 (TM -04 , 09, 15) ...................................... 26 3.4 Cesium-137 in Milk (Stations TM-16, 20) ................ 27 3.4.1 Cesium-137 (Milk) Annual Average Concentrations 1986-2001 (TM -16 , 20, 21) ........................................ 28 3.5 Gross Beta Measurements of Ground Water .................... 35 3.5.1 Gross Beta Measurements of Ground Water Semi-Annual Averages 1986-2001 ..................................... 36 3.6 Environmental Radiation Measurements, TL 01-05 ............ 60 3.6.1 Environmental Radiation Measurements, 1986-2001 TL-01, 02, 03, 04, 05 ................................ 61 3.7 Environmental Radiation Measurements, TL 06-10 ............ 62 3.7.1 Environmental Radiation Measurements, 1986-2001 TL-06, 07, 08, 09, 10 ................................ 63 3.8 Environmental Radiation Measurements, TL 11-15 ............ 64 3.8.1 Environmental Radiation Measurements, 1986-2001 TL-11 , 12, 13, 14, 15 ................................. 65 iv
3.9 Environmental Radiation Measurements, TL 16-20 ......... 66 3.9.1 Environmental Radiation Measurements, 1986-2001 T1-16, 17, 18, 19, 20 ................ 67 3.10 Environmental Radiation Measurements, TL 21-25 ......... 68 3.10.1 Environmental Radiation Measurements, 1986-2001 TL-21, 22, 23, 24, 25 ............... 69 3.11 Environmental Radiation Measurements, TL 26-30 ......... 70 3.11 1 Environmental Radiation Measurements, 1986-2001 TL-26, 27, 28, 29, 30 ............... 71 3 .12 Environmental Radiation Measurements, TL 31-35 ......... 72 3.12.1 Environmental Radiation Measurements, 1986-2001 TL-31, 32, 33, 34, 35 ............... 73 3.13 Environmental Radiation Measurements, TL 36-40 ......... 74 3.13 1 Environmental Radiation Measurements, 1986-2001 TL-36, 37, 38, 39, 40 ............... 75 3 .14 Environmental Radiation Measurements, TL 41-47 ......... 76 3.14.1 Environmental Radiation Measurements, 1986-2001 TL-41, 42, 43, 44, 45, 46, 47 ....... 77 v
ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT 1.0 Introduction The North Atlantic Energy Service Corporation's (NAESCO) Radiological Environmental Monitoring Program at Seabrook Station has been designed and carried out to achieve the following specific objectives: To provide an indication of the appearance or accumulation of any radioactive material in the environment caused by the operation of the nuclear power station. To provide assurance to regulatory agencies and the public that the station's environmental impact is known and within anticipated limits. To verify the adequacy and proper functioning of station effluent controls and monitoring systems. To provide standby monitoring capability for rapid assessment of risk to the general public in the event of unanticipated or accidental releases of radioactive material. North Atlantic Energy Service Corporation collected the terrestrial samples. Normandeau Associates, Inc. collected the marine and sediment samples. After initial processing, the samples were sent to the Duke Engineering & Services Environmental Laboratory (DESEL) in Marlborough, Massachusetts for further processing and radionuclide analysis. The DESEL also processed the environmental thermoluminescent dosimeters (TLD's). This report is a summary of the findings of the Radiological Environmental Monitoring Program for 2001. It is being provided in compliance with Part A of Seabrook Stations Offsite Dose Calculation Manual (ODCM) and Technical Specification 6.8.1.3 as defined in the Technical Requirements Program (TRP) Manual 5.2-10.1. 1
2.0 Environmental Monitoring Program In this section, Table 2.1 outlines the monitoring program as specified in section TRP5.2-9.1 of the Technical Requirements Manual. Table 2.2 lists the operational sampling stations and their specific locations (distances are measured from the center of the Unit 1 Containment Building). The sampling locations are shown on maps in Figures 2.1 through 2.6 Below are listed the two-letter media codes and what they represent: AP Air Particulate CF Charcoal Filter TM Milk WG Ground Water WS Surface (Sea) Water SE Sediment FH Fin fish HA Lobsters MU Mussels (Shellfish) TL Direct Radiation (TLD) AL Irish Moss (algae) TF Food Crop 2
Table 2.1 Radioloqical Environmental Monitoring Program Media Sampling Frequency Required Analyses Air Particulate (AP) -Weekly Gross Beta
-Quarterly Composite Gamma spectroscopy Charcoal Filter (CF) -Weekly 1-131 Milk (TM) -Monthly; semimonthly Gamma spectroscopy When animals 1-131 are on pasture Surface (Sea) Water (WS) -Monthly Gamma spectroscopy -Quarterly Composite H-3 (composite)
Sediment (SE) -Semiannually Gamma spectroscopy Fish & Invertebrates -Quarterly or Gamma spectroscopy (FH, HA, MU) -Semiannually Direct Radiation (TL) -Quarterly Integrated gamma exposure Irish Moss (AL) -Semiannually Gamma Spectroscopy Ground Water (WG) -Quarterly Gamma Spectroscopy Gross Beta H-3 Food Crops (TF) -Monthly/Growing Season Gamma Spectroscopy
- 3
Table 2.2 Radiological Environmental Monitoring Locations 2001 Distance From Direction Station Code Station Plant From (Media - Sta. No.) Description Zone (km) Plant AP/CF-01+ PSNH Barge Landing Area 1 2.7 ESE AP/CF-02+ Hampton Marina 1 2.7 E AP/CF-03+ Southwest Boundary 1 0.8 SW AP/CF-04+ West Boundary 1 1.0 W AP/CF-05 Winnacunnet High School 1 4.0 NNE AP/CF-06+ Georgetown Substation 2 24.0 SSW AP/CF-07 PSNH Substation 1 5.7 NNW AP/CF-08 E&H Substation 1 3.4 SSE TM-04+ Salisbury, MA 1 5.2 SW TM-09+ Hampton, NH 1 5.3 NNW TM-15+ Hampton Falls, NH 1 6.9 NW TM-16 Kensington, NH 1 7.6 WNW TM-20+ Rowley, MA 2 17.0 S WG-01 Seabrook Town Wells 1 5.6 W WG-04 Seabrook Station Well No.4 1 1.0 N WG-13 Seabrook Station Well No.13 1 1.0 N WS-01+ Hampton-Discharge Area 1 5.3 E WS-51+ Ipswich Bay 2 16.9 SSE SE-02 Hampton-Discharge Area 1 5.3 E SE-07+ Hampton Beach 1 3.1 E SE-08 Seabrook Beach 1 3.2 ESE SE-52 Ipswich Bay 1 16.9 SSE SE-57 Plum Island Beach 2 15.9 SSE FH-03+ Hampton-Discharge Area 1 4.5 ESE FH-53+ Ipswich Bay 2 16.4 SSE HA-04+ Hampton-Discharge Area 1 5.5 E HA-54+ Ipswich 2 17.2 SSE MU-06+ Hampton-Discharge Area 1 5.2 E MU-09 Hampton Harbor 1 2.6 E MU-56+ Ipswich Bay 2 17.4 SSE MU-59 Plum Island 2 15.8 SSE AL-05 Hampton-Discharge Area 1 5.2 E AL-55 Ipswich Bay 2 17.4 SSE TF-01 Hampton Falls, NH 1 1.5 WNW TF-02 Hampton Falls, NH 1 5.0 WNW TF-03 Salisbury, Ma 1 5.1 SW TF-06 Ipswich, Ma 2 26.0 S 4
Table 2.2 (Cont'd) Radiological Environmental Monitoring Locations 2001 Distance From Direction Station Code Station Plant From (Media - Sta. No.) Description Zone (km) Plant TL-l+ Brimmer's Lane, 1 1.1 N Hampton Falls TL-2+ Landing Road, Hampton I 3.2 NNE TL-3+ Glade Path, Hampton Beach I 3.1 NE TL-4+ Island Path, Hampton Beach I 2.4 ENE TL-5+ Harbor Road, Hampton Beach I 2.7 E TL-6+ PSNH Barge Landing Area I 2.7 ESE TL-7+ Cross Road, Seabrook Beach I 2.6 SE TL-8+ Farm Lane, Seabrook I 1.1 SSE TL-9+ Farm Lane, Seabrook I 1.1 S TL-10+ Site Boundary Fence I 1.0 SSW TL-ll+ Site Boundary Fence I 1.0 SW TL-12+ Site Boundary Fence I 1.0 WSW TL-13+ Inside Site Boundary I 0.8 W TL-14+ Trailer Park, Seabrook I 1.1 WNW TL-15+ Brimmer's Lane, I 1.4 NW Hampton Falls TL-16+ Brimmer's Lane 1 1.1 NNW Hampton Falls TL-17+ South Road, North Hampton 0 7.9 N TL-18+ Mill Road, North Hampton 0 7.6 NNE TL-19+ Appledore Avenue, 0 7.9 NE North Hampton TL-20+ Ashworth Avenue, 0 4.1 ENE Hampton Beach TL-21+ Route 1A, Seabrook Beach 0 3.7 SE TL-22+ Cable Avenue, Salisbury 0 7.6 SSE Beach TL-23+ Ferry Road, Salisbury 0 8.1 S TL-24+ Ferry Lots Lane, 0 7.2 SSW Salisbury TL-25+ Elm Street, Amesbury 0 7.6 SW TL-26+ Route 107A, Amesbury 0 8.1 WSW TL-27+ Highland St. S. Hampton 0 7.6 W TL-28+ Rte. 150, Kensington 0 7.9 WNW TL-29+ Frying Pan Ln., Hampton Falls 0 7.4 NW TL-30+ Route 27, Hampton 0 7.9 NNW 5
Table 2.2 (Cont'd) Radiological Environmental Monitoring Locations 2001 Distance From Direction Station Code Station Plant From (Media - Sta. No.) Description Zone (km) Plant TL-31+ Alumni Drive, Hampton S 4.0 NNE TL-32+ Seabrook Elementary School S 1.9 S TL-33+ Dock Area, Newburyport S 9.7 S TL-34+ Bow Street, Exeter S 12.1 NW TL-35+ Lincoln Ackerman School S 2.4 NNW TL-36+ Route 97, Georgetown 2 22.0 SSW TL-37+ Post Office Plaistow, NH 2 26.0 WSW TL-38+ Emerson St. Hampstead, NH 2 29.0 W TL-39+ Fremont, NH 2 27.0 NW TL-40+ Newmarket, NH 2 24.0 NNW TL-41 Portsmouth, NH 2 21.0 NNE TL-42 Ipswich, MA 2 27.0 SSE TL-43 Education Center S 0.3 ENE TL-44 Rocks Road Landing S 0.5 SW TL-45 Hampton Fire Station S 4.5 NE TL-46 Seabrook Beach S 2.9 ESE TL-47 Hampton Falls, NH S 4.2 WNW 1 = Indicator Stations; 2 = Control Stations; 0 = Outer Ring TLD; I = Inner Ring TLD; S = Special Interest TLD
+ = Sample Locations Required by the Off-Site Dose Calculation Manual (ODCM) 6
Atlantic Ocean SE-07 A SE-08 At&,,d Radiological Environmental Monitoring Locations Within 4 Kilometers i ( C , , Precision Mapping, Copyright 1995,96, Just Softworks Inc. Portions Copyright 1992-1996 TRIUSIno. FIGURE 2.1 RADIOLOGICAL ENVIRONMENTAL MONITORING LOCATIONS WITHIN 4 KILOMETERS OF SEABROOKSTATION Kittery Portsmouth jRadiological Environmental Monitoring Locations Between 4 & 12 Kilometers ^' AP/CF-05 A A TM-15 T TM-16 W WG-01 Seabrook Station
- A Discharge Site WS-01 AL-05 o *"Uz IVIU-{o FH-03 HA-04 4
Salisbury Atlantic Ocean Precision Mapping, Copyright 1995,96, Just Softworks Inc., Portions Copyright 1992-1996 TRIUS, Inc. Figure 2.2 Radiological Environmental Monitoring Locations Between 4 & 12 Kilometers From Seabrook Station 8
Precision Mapping, Copyrght 1995,96, Just Softworks Inc., Portions Copyright 1992-1996 TRIUSInc. Figure 2.3 Radiological Environmental Monitoring Locations Outside 12 Kilometers of Seabrook Station 9
Atlantic Ocean L-05 L-46 Direct Radiation Monitoring Locations Within 4 Kilometers Precision Mapping, Copyright 1995,96, Just Softworks Inc.,Portions Copyright 1992-1996 TRIUS,Inc. FIGURE 2.4 DIRECT RADIATION MONITORING LOCATIONS WITHIN 4 KILOMETERS OF SEABROOK STATION L X- /
/ /
Portsmouth v/ A TL-18 A 1' TL-19 A A ATL-45 ,A, I TL-28 TL-29 J ATL .31 K \/ A TL-20 o . iston A TL--47 Sea brook tation AI Discharge Site/
- -- - - - - - - - -.I Atlantic Ocean Direct Radiation TL-22 Monitoring Locations Be een 4 - 12 Kilometers N
K Precision Mapping, Copyrght 1995,96, Just Softworks Ic., Portions Copyrght 1992-19W TRIUS,kIc, FIGURE 2.5 DIRECT RADIATION MONITORING LOCATIONS BETWEEN 4 and 12 KILOMETERS FROM SEABROOK STATION
/
K~tery TL-41 \* mouth "\
/ "
Station Atlantic Ocean TL-42 A Gloucester I
/ /
Precision Mapping, Copyright 1995,96, Just Softworks Inc., Portions Copyright 1992-1996 TRIUS, nc. FIGURE 2.6 DIRECT RADIATION MONITORING LOCATIONS OUTSIDE 12 KILOMETERS OF SEABROOK STATION 3.0 Summary of Radiological Environmental Data The following pages summarize the analytical results of the environmental samples, which were collected in 2001. Each environmental media category is presented as a separate subsection. A table that summarizes the data follows a discussion of the sampling requirements and results for each program. Listed at the top of each table are the units of measurement for each medium. The left-hand column contains the radionuclide, which is being reported, total number of analyses of that radionuclide, and the number of measurements that exceed ten times the yearly average of control measurements. The latter are classified as "non- routine" measurements. The next column lists the Lower Limit of Detection (LLD) for those radionuclides which have detection capability requirements specified in the Off-Site Dose Calculation Manual. Those sampling stations which are adjacent to the plant and which could conceivably be affected by the operation of Seabrook Station are called "Indicator" or "Zone 1" stations. Distant stations, which are beyond potential plant influences, are called "Control" or "Zone 2" stations. Direct radiation (TLD) monitoring locations are subdivided into site boundary, inner ring, and outer ring (emergency response) stations. A set of statistical parameters is calculated for each radionuclide. This set of statistical parameters includes separate analyses for (1) the indicator stations, (2) the station having the highest annual mean concentration for that radionuclide, (3) and control stations. For each of these three groups of data, these parameters are as follows:
- The mean value of all concentrations.
- The range of values.
The number of positive measurements (a concentration which is greater than the a posteriori LLD for that analysis) divided by the total number of measurements. Each single radioactivity measurement in media datum in this report is based on a single measurement and is reported as a concentration plus or minus a one standard deviation uncertainty. The quoted uncertainty term represents only the random uncertainty associated with the radioactive decay process (counting statistics), and not the propagation of all possible uncertainties in the analytical procedure. Attachment I contains the data for the samples collected in 2001. The results are organized by sample type, within each sample type listing the data is alphabetical by nuclide, within each nuclide listing the data is chronologically arranged by end date (date of sample collection). The radionuclide value concentrations (charcoal media) have been corrected for radioactive decay to the end of the collection. The airborne radioiodine (charcoal) concentrations have been calculated assuming a constant flow rate and concentration throughout the collection period and correcting for decay while sampling as well as between sample collection termination and analysis. Pursuant to ODCM requirements, any concentration below the LLD for its analysis is reported as "not detected". These values are set to zero for averaging purposes. Where a range of values is reported in the tables of this section, values less than the a posteriori LLD for the analysis are reported as zero. 13
A) Air Particulate Air monitoring stations were established at a total of eight locations (Five are required by the Offsite Dose Calculation Manual). Seven of the locations are indicators, while the remaining one is a control station. Airborne particulates are collected by passing the air through a glass-fiber filter. These filters are collected weekly and held for at least 100 hours before being analyzed for gross-beta activity (indicated as GR-B in tables) to allow for the decay of radon daughter products. For the year, 423 particulate filters were collected for gross beta activity. One weekly air sample was not collected and analyzed. The gross beta activity for the indicator locations is statistically equivalent to that seen at the control station. The gross beta results for all stations is also similar to what was seen in the preoperational program and for the last nine years of commercial operation. Fluctuations seen in the gross beta activity throughout the year can be attributed to changes in the environment. Concentrations of naturally occurring radionuclides in the atmosphere directly above land are affected by natural environmental processes such as wind direction, precipitation, snow cover, and soil temperature and moisture. No plant related gamma-emitting radionuclides were detected in any of the quarterly composite air filters samples analyzed. Therefore no increasing or decreasing trend exists. In 2001, naturally occurring Be-7 was the only nuclide detected. Be-7 is of cosmogenic origin. This is consistent with previous years both pre and post operationally. For week #32, air sample station #1 was found to be off at the time of filter change out. A sample was not available for collection. Two Condition Reports (CR) were initiated. The second CR provides more detail as to disposition. The Kurz air sample pump was replaced. The air particulate sampling program demonstrated no off-site dose to the public or impact to the environment, from this pathway, as the result of plant operations. This is consistent with previous years and the preoperational program. 14
FIGURE 3.1 GROSS-BETA MEASUREMENTS OF AIR PARTICULATE FILTERS SEABROOK STATION 0.08 0.08 0.07 0.07 0.06 0.06 0.05 0.05 E - 0.04 0.04 0.03 A 0.03 0.02 0.02 0.01 0.01 00 January March May July September November January 2001
-a-AP-01 Barge Landing Area 4-AP-02 Hampton Marina -j----AP-03 SW Boundary -AP-04 W Boundary -A--AP-05 Winnacunnet High School -- *-- AP-06 Georgetown Substation (Control) -*AP-07 PSNH Substation, Hampton - AP-08 Exeter & Hampton Electric Co.
Page 15
FIGURE 3.1.1 GROSS-BETA MEASUREMENTS OF AIR PARTICULATE FILTERS QUARTERLY AVERAGES SEABROOK STATION 0.16 0.16 Chernobyl May, 1986 0.14 0.14 0.12 0.12 0.1 0.1 E . 0.08 0.08 "5%Criticality o.. June, 1989 a- 0.06 0.06 Full Power 0.04 ~May, 1990 00 0.04 -- 0.04 0.02 0.02 1986 1988 1990 1992 1994 1996 1998 2000 2002
-o--- AP-01 Barge Landing Area -....-AP-02 Hampton Marina ---- AP-03 SW Boundary -- X- AP-06 Georgetown Substation (Control) 16
FIGURE 3.1.2 GROSS-BETA MEASUREMENTS OF AIR PARTICULATE FILTERS QUARTERLY AVERAGES SEABROOK STATION 0.16 Chernobyl May, 1986 0.14 0.12 0.1 E Z 0.08 0 5% Criticality "-0. June, 1989 o0.06 Full Power 0.04 May, 1990 0.02 1986 1988 1990 1992 1994 1996 1998 2000 2002
-o-- AP-04 W Boundary --El-- AP-05 Winnacunnet High School -i-- AP-06 Georgetown Substation (Control) 17
FIGURE 3.1.3 GROSS-BETA MEASUREMENTS OF AIR PARTICULATE FILTERS QUARTERLY AVERAGES SEABROOK STATION 0.16 Chernobyl May, 1986 0.14 0.12 0.1 E Z 0.08 0 z 5% Criticality o_ 0.06 *1 June, 1989I Full Power 0.04 May, 1990 0.02 1986 1988 1990 1992 1994 1996 1998 2000 2002
-o- AP-06 Georgetown Substation (Control) -- AP-07 PSNH Substation, Hampton -&AP-08 Exeter & Hampton Electric Co.
18
FIGURE 3.2 GROSS-BETA ON AIR PARTICULATE FILTERS QUARTERLY AVERAGES SEABROOK STATION 0.08 0.08 0.06 - 0.06 E 0.04- 0.04 0 0 0-) 0.02 0.02 11-
%0%1 0ýv 0 -I. S 0
1994 1995 1996 1997 1998 1999 2000 2001
-l-- Indicators .- O Control 19
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Air Particulates (AP) UNITS: pCVcublc meter Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected**) (No. Detected**) (No. Detected-*) GR-B (423) 0.01 2.0E -2 05 2.5E -2 2.OE -2 (0) ( 4.9 - 49.6)E -3 6.3 - 49.6)E -3 6.1 - 35.5)E -3 (370/ 370) (53/ 53) (53/ 53) Be-7 (32) 8.9E -2 05 1.3E -1 8.OE -2 (0) 4.5 - 17.1)E -2 9.2 - 17.1)E -2 5.3 - 12.1)E -2 (28/ 28) (4/ 4) (4/ 4) K-40 (32) 1.8E -3 04 4.9E -3 -1.5E -3 (0) ( -6.2 - 13.0)E -3 -4.4 - 72.3)E -4 -3.3 - 0.3)E -3 (0/ 28) (0/ 4) (0/ 4) Cr-51 (32) 2.2E -4 04 8.8E -3 4.1E -3 (0) -2.5 - 2.3)E -2 -3.3 - 20.0)E -3 -9.4 - 16.8)E -3 (0/ 28) (0/ 4) (0/ 4) Mn-54 (32) -5.2E -5 06 2.4E -4 2.4E -4 (0) -6.7 - 6.6)E -4 0.0 - 6.8)E -4 ( 0.0 - 6.8)E -4 (0/ 28) (0/ 4) (0/ 4) 1.3E -5 08 9.2E -5 -1.7E -4 Co-57 (32) (0) -2.6 - 3.2)E -4 4.2 - 15.1)E -5 -2.8 - 0.0)E -4 (0/ 28) (D/ 4) (0/ 4) Co-58 (32) -5.8E -5 07 3.9E -4 -3.2E -4 (0) -1.0 - 1.2)E -3 -1.6 - 7.6)E -4 -6.5 - -1.0)E -4 (0/ 28) (0/ 4) (0/ 4) Fe-59 (32) -3.1E -4 07 9.2E -4 -4.4E -4 (0) -6.0 - 6.0)E -3 -4.2 - 6.0)E -3 -2.1 - 1.0)E -3 (01 28) (0/ 4) (0/ 4) Co-60 (32) 7.4E -5 02 4.3E -4 -4.OE -4 (0) -9.1 - 13.4)E -4 -2.1 - 133.6)E -5 -8.0 - 3.6)E -4 (0/ 28) (0/ 4) (0/ 4)
-1.2E -3 06 -1.4E -4 -1.4E -4 Zn-65 (32) -4.6 - 1.0)E -3 -1.1 - 1.1)E -3 -1.1 - 1.1)E -3 (0)
(0/ 28) (0/ 4) (0/ 4)
-2.4E -5 06 4.6E -4 4.6E -4 Se-75 (32)
(0) -8.1 - 8.7)E -4 0.0 - 1.6)E -3 0.0 - 1.6)E -3 (0/ 28) (0/ 4) (0/ 4) O.OE 0 08 3.2E -4 2.4E -4 Zr-95 (32)
-2.1 - 2.0)E -3 -5.8 - 16.6)E -4 -1.1 - 2.7)E -3 (0)
(0/ 28) (0/ 4) (0/ 4) 20
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Air Particulates (AP) UNITS: PCi/cubic meter Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected-) (No. Detected*) (No. Detected*) Ru-103 (32) -1.8E -4 03 1.3E -4 -8.6E -5 (0) -1.2 - 1.2)E -3 -6.2 - 7.7)E -4 -7.6 - 6.3)E -4 (0/ 28) (O/ 4) (O/ 4) Ru-106 (32) 4.8E -4 05 4.OE -3 -2.1E -4 (0) -8.8 - 6.8)E -3 ( 2.1 - 5.7)E -3 -4.3 - 2.7)E -3 (0/ 28) (O/ 4) (O/ 4) Ag-110M (32) -2.9E -5 05 3.1E -4 -1.3E -4 (0) -1.0 - 0.8)E -3 1 -9.2 - 56.8)E -5 -5.4 - 4.2)E -4 (0/ 28) (O/ 4) (O/ 4) Sb-124 (30) 4.5E -4 03 1.6E -3 -8.1E -4 (0) -2.6 - 3.6)E -3 -1.1 - 3.6)E -3 -1.4 - 00)E -3 (0/ 27) (O/ 4) (O/ 3) 1-131 (32) 9.8E -3 03 8.7E -2 -1.1E -1 (0) -2.9 - 2.0)E -1 -6.5 - 197.2)E -3 -5.4 - 0.9)E -1 (O/ 28) (O/ 4) (O/ 4) Cs-134 (32) 0.05 0.OE 0 06 1.2E -4 1.2E -4 (0) -6.1 - 6.7)E -4 1.6 - 37.8)E -5 1.6 - 37.8)E -5 (0/ 28) (O/ 4) (O/ 4) Cs-137 (32) 0.06 -8.8E -5 01 9.6E -5 -2.1E -4 (0) -6.5 - 4.0)E -4 -2.3 - 4.0)E -4 -5.3 - 0.2)E -4 (O 28) (O/ 4) (O/ 4) Ba-140 (29) -4.1E -3 03 1.2E -2 4.0E -3 (0) -4.0 - 3.6)E -2 -5.8 - 36.0)E -3 -5.7 - 17.7)E -3 (0/ 26) (O/ 4) (O/ 3) Ce-141 (32) 2.4E -4 07 1.2E -3 5.1E -4 (0) -2.6 - 5.3)E -3 -1.1 - 5.3)E -3 -4.8 - 16.6)E -4 (O/ 28) (O/ 4) (O/ 4) Ce-144 (32) -3.3E -4 07 1.3E -3 3.1E -4 (0) -3.5 - 2.1)E -3 -2.6 - 20.6)E -4 -5.9 - 19.3)E -4 (0/ 28) (O0 4) (O/ 4) Th-232 (32) 1.6E -4 02 8.9E -4 -4.2E -4 (0) -2.3 - 2.4)E -3 6.9 - 13.3)E -4 -1.3 - 0.3)E -3 (0/ 28) (O0 4) (O/ 4)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
**The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
21
B) Charcoal Filters Charcoal filter cartridges are in series with the air particulate glass-fiber filters. Monitoring stations were established at a total of eight locations (five are required by the ODCM) . Seven of these are indicators and one is a control. Charcoal filters from the air sampling stations were collected and analyzed weekly for 1-131 activity. During 2001, A total of 423 charcoal cartridges from all eight locations were analyzed. As was the case with particulate air samples, one samples were missed for the year (see section A). No sample analysis indicated a detectable measurement for 1-131 that was statistically relevant (positive) at the air sampling locations stated in the ODCM and as stated in the Technical Requirements Manual. The REMP program has detected no radioiodine at any offsite air sample location, since Seabrook Station's initial criticality of June 1989. There is no dose to the public or impact to the environment from this pathway. The preoperational data for 1-131 are consistent with present data. Therefore, no increasing or decreasing trend exists. 22
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Charcoal Cartridge (OF) UNITS: pCi/cublc meter Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected-) (No. Detected*) (No. Detected*) 1-131 (423) 0.07 1.4E -4 08 1.7E -3 8.9E -4 (0) -2.9 - 2.6)E -2 ( -2.9 - 1.9)E -2 ( -1.7 - 1.7)E -2 (0/ 370) (0/ 53) (0/ 53) Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3. The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses. 23
C) Milk Milk samples were collected every two weeks during the pasture season and monthly at other times. Samples are analyzed for 1-131 and gamma-emitting radionuclides. Milk samples were collected from four indicator and two control locations for the year. Three of the indicator locations and one control are required by Technical Specifications. The required Indicator locations range from 5.2 to 6.9 km from the Plant while the Control location is 17 km from the Plant. A CR was generated in the first quarter of 2001 to document the fact that a backup control station went out of business. This occurrence was documented in the 2000 submittal. A total of 90 milk samples were collected within the year. Each sample was analyzed for gamma emitting radionuclides. In addition, all samples are evaluated for 1-131 through an iodine extraction process. Gamma analysis indicated only potassium-40 and cesium-137 was present. Detectable concentrations of Cs-137 were measured in several samples collected in 2001. Four positive results for Cs-137 were detected at required location TM
- 16. It has been shown in the preoperational program that this nuclide is the result of atmospheric nuclear weapons testing that persists in the environment. The levels of Cs-137 detected in 2001 are consistent with that detected in the pre-operational phase and during the first nine years of commercial operations.
Potassium-40 was detected in all indicator and control locations. Potassium-40 is a naturally occurring nuclide detected in many environmental sample media. Iodine-131 was not positively identified at any required or added location for the year. The samples met the Lower Limit of Detection (LLD) requirements (1 pCi's/kg) for 1-131 in milk. This is consistent with previous years for both the pre-operational and operational phases of the program. The calculated dose as the result of plant effluents is not evaluated due to the fact that no plant related radionuclides were detected. The milk-sampling program demonstrated that there is no impact to the public or environment, through this pathway, from plant operations. Therefore, no increasing or decreasing trend exists. 24
FIGURE 3.3 CESIUM-137 IN MILK SEABROOK STATION 30 25 20 15 C- 10 0
-10 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2001 ---- TM-04 Dairy Farm, Salisbury, MA -a-TM-09 Dairy Farm, Hampton NH -&-TM-15 Goat Herd, Hampton Falls NH -TM-16 Goat Herd, Kensington, NH --- TM-16 Positive Concentration 25
FIGURE 3.3.1 CESIUM-137 IN MILK ANNUAL AVERAGE CONCENTRATIONS 50 50 40 40 30 30 __ Chernobyl o May, 1986 CL 20 20 5% Criticality June, 1989 Full Power 0 00 0* i 0 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 TM-04 Dairy Farm, Salisbury MA
-o--TM-08 (prior to 1995 TM-10) Dairy Farm, Hampton Falls NH --O-TM-09 Dairy Farm, Hampton NH -A-TM-15 Goat Herd, Hampton Falls NH 26
FIGURE 3.4 CESIUM -137 IN MILK SEABROOK STATION 30 25 20 15 C0O 10 5 0
-5 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 2001 -- -- TM-16 Goat Herd, Kensington, NH -O--TM-20 Dairy Farm, Rowley MA (Control) - TM-16 Positive Concentration 27
FIGURE 3.4.1 CESIUM-137 IN MILK ANNUAL AVERAGE CONCENTRATIONS 50 50 40 40 30 30 0) S~20 o Chernobyl C" May, 1986 20 5% Criticality June,1989 10 Full Power EL. "-* iqk May, 1990 1.10 100 0- -10 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001
-*-TM-16 Goat Herd, Kensington NH -A-TM-21 Dairy Farm, N. Andover MA (Control) --TM-20 Dairy Farm, Rowley MA (Control) 28
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Milk (TM'I UNITS: nCl/ka Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected*) (No. Detected*-) (No. Detected*) Be-7 (90) -1.1E 0 15 4.7E 0 3.6E 0
-3.8 - 3.2)E 1 -2.8 - 3.2)E 1 -2.2 - 2.9)E 1 (0)
(0/ 72) (0/ 18) (0/ 18) 1.5E 3 16 1.9E 3 1.4E 3 K-40 (90) (0) 1.1 - 2.1)E 3 1.6 - 2.1)E 3 1.2 - 1.5)E 3 (72/ 72) (18/ 18) (18/ 18) Cr-51 (90) -1.2E 0 09 2.2E 0 6.2E -1 (0) -3.9 - 4.5)E 1 -3.9 - 4.5)E 1 -2.4 - 2.9)E 1 (0/ 72) (0/ 18) (0/ 18) M n-54 (90) -2.7E -1 04 4.3E -2 -7.7E -3 (0) -3.1 - 2.8)E 0 -2.7 - 1.8)E 0 -2.0 - 2.0)E 0 (0/ 72) (0/ 18) (0/ 18) Co-57 (90) -8.8E -3 04 3.1E -1 -1.4E -1
-2.3 - 2.3)E 0 -1.4 - 2.2)E 0 -2.0 - 1.9)E 0 (0)
(0/ 72) (0/ 18) (0/ 18) Co-58 (90) -5.2E -1 09 -2.4E -1 -8.5E -1 (0) -4.6 - 2.8)E 0 -2.7 - 2.1)E 0 -3.0 - 2.1)E 0 (0/ 72) (0/ 18) (0/ 18) Fe-59 (90) -6.2E -1 16 3.5E -1 4.0E -2 (0) -1.2 - 1.2)E 1 -1.2 - 0.9)E 1 -6.6 - 8.5)E 0 (0/ 72) (0/ 18) (0/ 18) Co-60 (90) 1.6E -1 15 2.8E -1 -5.2E -1 (0) -3.3 - 3.7)E 0 -3.3 - 3.7)E 0 -4.5 - 3.6)E 0 (0/ 72) (0/ 18) (0/ 18) (90) -2.9E 0 16 -1.5E 0 -1.8E 0 Zn-65 (0) -1.2 - 0.7)E 1 -9.0 - 7.2)E 0 -6.7 - 18.1)E 0 (0/ 72) (0/ 18) (0/ 18) Se-75 (90) 2.6E -1 04 5.8E -1 5.1E -1
-4.5 - 4.3)E 0 -4.1 - 4.3)E 0 -2.8 - 4.1)E 0 (0)
(0/ 72) (0/ 18) (0/ 18) 8.5E -2 15 3.7E -1 -7.7E -1 Zr-95 (90) (0) -6.3 - 7.0)E 0 -6.3 - 4.1)E 0 -3.8 - 2.6)E 0 (0/ 72) (0/ 18) (0/ 18) Ru-103 (90) -1.1E 0 09 -3.6E -1 -1.6E 0
-3.9 - 3.0)E 0 -2.9 - 3.0)E 0 -3.2 - -0.4)E 0 (0)
(0/ 72) (0/ 18) (0/ 18)
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Milk (TM) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected**) (No. Detected-) (No. Detected*) Ru-106 (90) -6.6E -1 15 5.6E 0 4.1E 0 (0) -2.9 - 2.7)E 1 -2.5 - 2.7)E 1 -1.6 - 2.3)E 1 (0/ 72) (0/ 18) (0/ 18) Ag-110M (90) 2.4E -1 09 6.5E -1 -7.0E -2 (0) -4.8 - 6.2)E 0 -3.7 - 4.1)E 0 -4.7 - 1.8)E 0 (0/ 72) (0/ 18) (0/ 18) Sb-124 (90) 2.8E -1 04 1.2E 0 -1.4E -1 (0) -9.0 - 7.3)E 0 -2.9 - 7.3)E 0 -3.2 - 5.2)E 0 (0/ 72) (0/ 18) (0/ 18) 1-131 (90) 1 9.OE -2 09 1.4E -1 7.5E -2 (0) -8.6 - 75.8)E -2 -8.3 - 75.8)E -2 -9.3 - 50.1)E -2 (0/ 72) (0/ 18) (0/ 18) Cs-1i34 (90) 15 1.2E -1 16 3.OE -1 -9.OE -2 (0) -3.5 - 4.9)E 0 -3.5 - 4.9)E 0 -3.0 - 3.0)E 0 (0/ 72) (0/ 18) (o/ 18) Cs-137 (90) 18 2.1E 0 16 3.8E 0 6.4E -1 (0) -3.3 - 12.9)E 0 -3.3 - 12.9)E 0 -1.9 - 2.4)E 0 (4/ 72) (4/ 18) (0/ 18) Ba-140 (90) 15 2.8E -1 16 9.9E -1 8.8E -1 (0) -5.7 - 6.7)E 0 -2.0 - 6.7)E 0 -2.1 - 3.7)E 0 (0/ 72) (0/ 18) (0/ 18) Ce-141 (90) -4.2E -1 15 2.4E -1 -1.2E 0 (0) -7.2 - 6.3)E 0 -5.0 - 5.2)E 0 -4.2 - 3.2)E 0 (0/ 72) (0/ 18) (0/ 18) Ce-144 (90) 2.2E 0 09 5.8E 0 -2.2E 0 (0) -1.8 - 2.3)E 1 -1.8 - 2.3)E 1 -2.0 - 1.4)E 1 (0/ 72) (0/ 18) (o/ 18) Th-232 (90) 6.7B -1 09 1.8E 0 9.2E -1 (0) -1.2 - 1.7)E 1 -8.5 - 16.8)E 0 -9.3 - 8.2)E 0 (0/ 72) (0/ 18) (0/ 18)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
30
D) Surface Water Surface water (seawater) grab samples are required at two locations (control and indicator) monthly. The indicator (01) is over the vicinity of the plant discharge. The control location (51) is located in Ipswich Bay, MA. A gamma analysis is performed on each sample. A tritium analysis is performed on the quarterly composite of these samples. For the year, 23-gamma analyses were performed on surface water samples. A CR was generated to document the fact that a seawater sample was not collected from the control location (Ipswich Bay) for week #8. This was due to heavy weather and high seas for the prescribed collection period. The only radionuclide detected in 2001 was naturally occurring K-40. No plant related nuclides were detected. The present data for gamma emitters in seawater is consistent with that of the pre-operational program and the last twelve years of operations. Therefore, no increasing or decreasing trend exists. Quarterly composites from the same gamma collection samples were analyzed for tritium. Eight samples were analyzed in 2001. The monthly composites showed no presence of tritium. The composites met the required LLD (3000 pCi's/kg) for tritium in seawater. These results are consistent with preoperational tritium data. The calculated dose, as the result of plant effluents is not evaluated due to the fact that no plant related radionuclides were or have been detected. Therefore, no increasing or decreasing trend exists. This sampling program demonstrates that there is no impact to the public or environment, through this pathway, from plant operations. 31
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Sea Water (WS) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected*) (No. Detected*) (No. Detected*) H-3 (8) 3000 1.4E 2 01 . 4E 2 3.2E 1 (0) -2.1 - 8.0)E 2 -2.1 - 8.0)E 2 -2.1 - 2.2)E 2 (0/ 4) (0/ 4) (0/ 4) Be-7 (23) 1.2E 0 01 1.2E 0 -6.3E 0 (0) -1.5 - 1.4)E 1 -1.5 - 1.4)E 1 -1.7 - 0.7)E 1 (0/ 12) (0/ 12) (0/ 11) K-40 (23) 3.OE 2 01 3.OE 2 3.OE 2 (0) 2.5 - 3.6)E 2 2.5 - 3.6)E 2 ( 2.1 - 3.7)E 2 (12/ 12) (12/ 12) (11/ 11) Cr-51 (23) -3.7E -1 01 -3.7E -1 -1.7E 0 (0) -2.2 - 1.9)E 1 -2.2 - 1.9)E 1 -1.7 - 1.B)E 1 (0/ 12) (0/ 12) (0/ 11) Mn-54 (23) 15 -5.OE -1 51 2.9E -2 2.9E -2 (0) -2.3 - 1.2)E 0 -1.8 - 1.7)E 0 -1.8 - 1.7)E 0 (0/ 12) (0/ 11) (0/ 11) Co-57 (23) 1.8E -1 51 3.1E -1 3.1E -1 (0) -1.6 - 1.7)E 0 -1.4 - 2.0)E 0 -1.4 - 2.0)E 0 (0/ 12) (0/ 11) (01 11) Co-58 (23) 15 -6.3E -1 51 -4.3E -1 -4.3E -1 (0) -1.9 - 0.6)E 0 -2.2 - 0.5)E 0 -2.2 - 0.5)E 0 (0/ 12) (0/ 11) (0/ 11) Fe-59 (23) 30 1.4E -1 01 1.4E -1 -1.1E 0 (0) -4.9 - 4.3)E 0 -4.9 - 4.3)E 0 -4.2 - 5.3)E 0 (0/ 12) (0/ 12) (0/ 11) Co-60 (23) 15 6.8E -1 01 6.8E -1 7.4E -3 (0) -9.5 - 27.2)E -1 -9.5 - 27.2)E -1 -1.7 - 1.5)E 0 (0/ 12) (0/ 12) (0/ 11) Zn-65 (23) 30 -3.7E -1 01 -3.7E -1 -2.4E 0 (0) -1.0 - 1.4)E 1 -1.0 - 1.4)E 1 -9.1 - 6.7)E 0 (0/ 12) (0/ 12) (0/ 11) Se-75 (23) -6.5E -1 51 -6.3E -1 -6.3E -1 (0) -4.6 - 2.5)E 0 -3.0 - 1.8)E 0 -3.0 - 1.8)E 0 (0/ 12) (0/ 11) (0/ 11) Zr-95 (23) 15 -4.9E -2 51 2.9E -1 2.9E -1 (0) -2.2 - 2.7)E 0 -2.9 - 2.6)E 0 -2.9 - 2.6)E 0 (0/ 12) (0/ 11) (0/ 11) 32
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Sea Water (WS) UNITS: oCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected*) (No. Detected-) (No. Detected-) Ru-103 (23) -5.6E -1 01 -5.6E -1 -6.4E -1
-2.5 - 0.9)E 0 -2.5 - 0.9)E 0 -2.6 - 1.3)E 0 (0)
(0/ 12) (0/ 12) (0/ 11)
-4.6E 0 51 -3.2E 0 -3.2E 0 Ru-106 (23)
(0) -2.7 - 1.4)E 1 -1.2 - 0.2)E 1 -1.2 - 0.2)E 1 (0/ 12) (0/ 11) (0/ 11)
-4.4E -1 51 5.5E -1 5.5E -1 Ag-i 1DM (23)
(0) ( -1.8 - 2.3)E 0 -1.5 - 4.6)E 0 -1.5 - 4.6)E 0 (0/ 12) (0/ 11) (0/ 11)
-6.OE -3 51 3.1E -1 3.1E -1 Sb-1i24 (23) -4.3 - 4.4)E 0 -2.8 - 3.6)E 0 -2.8 - 3.6)E 0 (0)
(0/ 12) (0/ 11) (0/ 11) 1-131 (23) 15 2.3E -1 51 3.9E -1 3.9E -1
-2.5 - 4.6)E 0 -1.7 - 5.2)E 0 -1.7 - 5.2)E 0 (0)
(0/ 12) (0/ 11) (0/ 11) 15 -2.6E -1 51 -1.2E -2 -1.2E -2 Cs-1 34 (23)
-2.9 - 1.9)E 0 -1.4 - 2.1)E 0 -1.4 - 2.1)E 0 (0)
(0/ 12) (0/ 11) (0/ 11) 18 -9.6E -1 51 -2.4E -1 -2.4E -1 Cs-1i37 (23) (0) -3.9 - 0.5)E 0 -2.0 - 1.3)E 0 -2.0 - 1.3)E 0 (0/ 12) (0/ 11) (0/ 11) 15 9.5E -2 01 9.5E -2 -2.8E -1 Ba-140 (23)
-2.2 - 2.7)E 0 -2.2 - 2.7)E 0 -4.7 - 3.1)E 0 (0)
(0/ 12) (0/ 12) (0/ 11) 01 7.5E -1 -3.0E -1 Ce-141 (23) 7.5E -1
-1.9 - 2.5)E 0 -1.9 - 2.5)E 0 -3.7 - 5.1)E 0 (0)
(0/ 12) (0/ 12) (0/ 11)
-2.7E 0 51 -1.7E 0 -1.7E 0 Ce-144 (23) -1.6 - 1.2)E 1 -1.5 - 1.1)E 1 -1.5 - 1.1)E 1 (0)
(0/ 12) (0/ 11) (0/ 11) 1.4E 0 01 1.4E 0 -2.3E 0 Th-232 (23)
-3.1 - 8.7)E 0 -3.1 - 8.7)E 0 -6.2 - 3.7)E 0 (0)
(0/ 12) (0/ 12) (0/ 11)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
** The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
33
E) Ground Water There is no requirement to collect ground water samples. For the year, four quarterly ground water samples were collected from two locations. These samples were analyzed for gross-beta activity, gamma-emitters and tritium. These samples were collected from the drinking water line supplied to the Site (by the Town of Seabrook) and from an inactive well located approximately 1 km North of the plant. One CR was generated that concerned a missed gross beta analysis for week #49. The samples were subsequently reanalyzed for the missed gross beta test. Gross beta activity was detected in seven of the eight samples taken and is due to naturally occurring radium and its daughter products. The gross beta activity seen at both locations is similar to what was seen in the preoperational program and are consistent with results over the last ten years of commercial operations. No tritium or gamma emitters were detected. The calculated dose is not evaluated due to the fact that plant related radionuclides have not been detected. Therefore no increasing or decreasing trend exists. There is no impact to the public, through this pathway, from plant operations. 34
FIGURE 3.5 GROSS-BETA MEASUREMENTS OF GROUND WATER SEABROOK STATION 20.00 20.00 18.00 18.00 16.00 16.00 14.00 14.00 12.00 12.00 10.00 10.00 8.00 8.00 6.00 6.00 4.00 -4.00 2.00 2.00 0.00 I I I I I J I 0.00 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan 2001
----- WG-01 Seabrook Town Wells -x- WG-13 Seabrook Station Well No. 13 35
FIGURE 3.5.1 GROSS-BETA MEASUREMENTS OF GROUND WATER SEMI-ANNUAL AVERAGES SEABROOK STATION 20 20 15 15 S10 10 5 5 0 I I 1n 1 I I I I i I 1 0 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002
-X- WG-01 Seabrook Town Wells -WG-13 Seabrook Station Well No. 13 36
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Ground Water (WG) UNITS: pCVkg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected*-) (No. Detected**) (No. Detected*) GR-B (8) 4 5.1E 0 01 6.7E 0 NO DATA (0) 1.6 - 7.5)E 0 5.5 - 7.5)E 0 (7/ 8) (4/ 4) H-3 (8) 3000 1.3E 2 01 1.6E 2 NO DATA (0) -1.6 - 5.4)E 2 0.0 - 5.4)E 2 (0/ 8) (0/ 4) Be-7 (8) -1.5E 0 13 -6.5E -1 NO DATA (0) -1.2 - 1.3)E 1 -3.6 - 2.2)E 0 (0/ 8) (0/ 4) K-40 (8) -7.6E 0 13 -3.4E 0 NO DATA (0) -3.3 - 1.7)E 1 -1.8 - 1.7)E 1 (0/ 8) (0/ 4) Cr-51 (8) 4.0E 0 13 1.2E 1 NO DATA (0) -2.3 - 3.6)E 1 0.0 - 3.6)E 1 (0/ 8) (0/ 4) Mn-54 (8) 15 1.4E -1 01 2.4E -1 NO DATA (0) -1.3 - 2.8)E 0 -1.1 - 2.8)E 0 (0/ 8) (0/ 4) Co-57 (8) -1.8B -1 13 2.1E -1 NO DATA (0) -1.1 - 0.9)E 0 -6.2 - 8.5)E -1 (0/ 8) (0/ 4) Co-58 (8) 15 -5.6E -1 13 -2.7E -1 NO DATA (0) -1.8 - 1.6)E 0 -1.8 - 1.6)E 0 (0/ 8) (0/ 4) Fe-59 (8) 30 -1.0E 0 13 -8.9E -1 NO DATA (0) -4.8 - 4.7)E 0 -4.8 - 4.7)E 0 (0/ 8) (0/ 4) Co-60 (8) 15 -1.2E -2 13 3.OE -2 NO DATA (0) -2.1 - 1.3)E 0 -1.8 - 1.2)E 0 (0/ 8) (0/ 4) Zn-65 (8) 30 -1.2E 0 01 -2.2E -1 NO DATA (0) -1.0 - 1.2)E 1 -7.4 - 11.9)E 0 (0/ 8) (0/ 4) Se-75 (8) 4.6E -1 13 1.6E 0 NO DATA (0) -4.1 - 3.3)E 0 -1.2 - 32.6)E -1 (0/ 8) (0/ 4) 37
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Ground Water (WG) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected-) (No. Detected**) (No. Detected-) Zr-95 (8) 15 7.4E -1 01 1.2E 0 NO DATA (0) -3.2 - 3.3)E 0 -8.1 - 32.9)E -1 (0/ 8) (0/ 4) Ru-103 (8) -3.9E -1 13 -3.1E -1 NO DATA (0) -2.0 - 1.2)E 0 -8.2 - 4.5)E -1 (0/ 8) (0/ 4) Ru-106 (8) -3.1E 0 13 -2.5E 0 NO DATA (0) -3.3 - 1.4)E 1 -1.3 - 1.3)E 1 (0/ 8) (0/ 4) Ag-110M (8) -6.3E -1 13 -3.6E -1 NO DATA (0) -2.5 - 2.0)E 0 -2.5 - 2.0)E 0 (0/ 8) (0/ 4) Sb-124 (8) -5.5E -1 01 4.9E -1 NO DATA (0) -6.3 - 3.1)E 0 -9.7 - 15.3)E -1 (0/ 8) (0/ 4) 1-131 (8) 15 1.1E -1 13 1.OE 0 NO DATA (0) -2.6 - 1.7)E 0 -2.8 - 16.9)E -1 (0/ 8) (0/ 4) Cs-134 (8) 15 7.1E -1 01 8.6E -1 NO DATA (0) -2.9 - 19.7)E -1 -2.3 - 19.7)E -1 (0/ 8) (0/ 4) Cs-137 (8) 18 -1.0E 0 13 -8.2E -1 NO DATA (0) -1.8 - 0.0)E 0 -1.4 - 0.0)E 0 (0/ 8) (0/ 4) Ba-140 (8) 15 -3.6E -1 13 1.1E -1 NO DATA (0) -3.5 - 3.8)E 0 -1.9 - 3.8)E 0 (0/ 8) (0/ 4) Ce-141 (8) -2.1E 0 01 -4.2E -1 NO DATA (0) -6.3 - 1.4)E 0 -2.5 - 1.4)E 0 (0/ 8) (0/ 4) Ce-144 (8) 6.4E 0 13 8.5E 0 NO DATA (0) 2.0 - 176.4)E -1 2.0 - 176.4)E -1 (0/ 8) (D/ 4) Th-232 (8) -3.9E -1 01 1.6E 0 NO DATA (0) -6.3 - 9.6)E 0 -4.3 - 9.6)E 0 (0/ 8) (0/ 4)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
**The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
38
F) Sediment Semiannual sediment sampling is required at one location, although a total of five locations, three indicators and two controls, are collected. The indicator stations are comprised of two beach sediment cores from Seabrook Beach and one subtidal sediment core taken from near the discharge structure. The control locations, both beach and subtidal, are both located within Ipswich Harbor. A total of 30 samples were collected for the year from all locations. Each sediment core was sectioned into 5-centimeter segments. Segment 1 extends from the top of the core to 5 centimeters, segment two extends from 5 to 10 centimeters and the third segment extends from 10 to 15 centimeters in depth. A gamma analysis was performed on each segment. The only radionuclides detected in 2001 were naturally occurring K-40 and Th-232 with its natural daughters. Potassium-40 was detected in all core samples at all depths from all locations. Thorium-232 and its daughters were present in 13 of the 18 indicator segments and in 9 of the 12 control segments. No plant related radionuclides were detected in any segment. No increasing or decreasing trend exists. This is consistent with the preoperational program and with previous years of plant operations. There is no dose to the public or impact to the environment from any pathways associated with these media. 39
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Sediment (SE) UNITS: Cil/ka Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected*) (No. Detected-) (No. Detected*) Be-7 (30) 3.7E 1 02 8.9E 1 -2.2E 0
-3.1 - 3.3)E 2 -3.1 - 3.3)E 2 -2.6 - 6.6)E 2 (0)
(0/ 18) (0/ 6) (0/ 12) 1.7E 4 08 2.OE 4 1.3E 4 K-40 (30) (0) 1.1 - 2.2)E 4 1.7 - 2.2)E 4 1.1 - 1.6)E 4 (18/ 18) (6/ 6) (12/ 12) 9.BE 1 07 1.5E 2 -2.4E 0 Cr-Si (30)
-4.3 - 4.6)E 2 -6.2 - 37.5)E 1 -3.3 - 3.4)E 2 (0)
(0/ 18) (0/ 6) (0/ 12) (30) 1.4E 0 52 1.3E 1 6.5E 0 Mn-54
-4.0 - 4.3)E 1 ( -3.5 - 7.6)E 1 -3.5 - 7.6)E 1 (0)
(0/ 18) (0/ 6) (0/ 12) 1.7E 0 07 1.9E 0 -7.2E 0 Co-57 (30)
-8.8 - 22.2)E 0 -7.3 - 14.6)E 0 -3.8 - 1.4)E 1 (0)
(0/ 18) (0/ 6) (0/ 12) Co-S8 (30) -9.1E 0 07 -2.2E 0 -1.1E 1 (0) -4.7 - 4.2)E 1 ( -2.0 - 2.3)E 1 -5.1 - 2.2)E 1 (0/ 18) (0/ 6) (0/ 12) (30) -1.6E 1 57 1.6E 1 1.3E 1 Fe-59 (0) -1.1 - 0.9)E 2 ( -1.1 - 1.0)E 2 -1.1 - 1.0)E 2 (0/ 18) 10/ 6) (0/ 12) Co-60 (30) 4.2E 0 07 1.7E 1 -9.3E -2 (0) -1.9 - 3.1)E 1 ( 7.8 - 31.4)E 0 -2.0 - 1.7)E 1 (0/ 18) (0/ 6) (0/ 12) 3.6E 1 52 1.OE 2 4.9E 1 Zn-65 (30) (0) -1.4 - 2.3)E 2 -9.9 - 32.7)E 1 -1.5 - 3.3)E 2 (0/ 18) (0/ 6) (0/ 12) (30) -5.7E 0 07 1.5E 0 -2.1E 0 Se-75 (0) -3.9 - 4.0)E 1 -2.6 - 2.0)E 1 -3.8 - 3.1)E 1 (0/ 18) (0/ 6) (0/ 12) 1.6E 1 52 6.OE 1 3.1E 1 Zr-95 (30) (0) -4.0 - 9.8)E 1 -1.6 - 15.3)E 1 -3.8 - 15.3)E 1 (0/ 18) (0/ 6) (0/ 12)
-3.2E 0 57 6.6E 0 -4.6E 0 Ru-103 (30)
( -4.0 - 2.5)E 1 -7.4 - 21.1)E 0 -6.8 - 2.1)E 1 (0) (0/ 18) (0/ 6) (0/ 12) 40
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Sediment (SE'/ UNITS: UNITS: oCi/ko oCi/ko MEDIUM: Sediment (SE) Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected-) (No. Detected-) (No. Detected*) Ru-106 (30) -4.1E 1 57 2.3E 1 2.3E 1 (0) -2.6 - 2.2)E 2 -1.4 - 1.9)E 2 -2.2 - 2.8)E 2 (0/ 18) (0/ 6) (0/ 12) Ag-110M (30) -1.5E 1 52 1.9E 1 9.3E 0 (0) -7.6 - 1.6)E 1 -9.7 - 53.9)E 0 -3.8 - 5.4)E 1 (0/ 18) (0/ 6) (0/ 12) Sb-1i24 (30) -2.3E 0 02 6.6E 0 -1.2E 1 (0) -3.8 - 5.1)E 1 -2.5 - 5.1)E 1 -1.1 - 0.6)E 2 (0/ 18) (0/ 6) (0/ 12) 1-131 (30) -2.2E 1 52 1.OE 2 -2.1E 1
-3.3 - 4.8)E 2 -6.7 - 24.8)E 1 -3.4 - 2.5)E 2 (0)
(0/ 18) (0/ 6) (0/ 12) Cs-1i34 (30) 150 -2.1E 1 02 1.4E 1 -I.OE 0 (0) -3.3 - 0.6)E 2 -5.8 - 6.2)E 1 -5.3 - 2.5)E 1 (0/ 18) (0/ 6) (0/ 12) Cs-137 (30) 180 4.3E 0 07 1.1E 1 -2.1E 1 (0) -2.5 - 3.6)E 1 -1.5 - 3.3)E 1 -6.7 - 0.6)E 1 (0/ 18) (0/ 6) (0/ 12) Ba-140 (30) 5.9E 0 07 7.8E 1 -1.3E 2 (0) -6.0 - 3.4)E 2 -1.4 - 2.6)E 2 -5.0 - 4.6)E 2 (0/ 18) (0/ 6) (0/ 12) Ce-1 41 (30) -9.5E 0 52 4.OE 1 1.1E 1 (0) -7.8 - 2.0)E 1 -1.0 - 10.4)E 1 -8.8 - 10.4)E 1 (0/ 18) (0/ 6) (01 12) Ce-1 44 (30) -1.7E 1 08 5.7E 0 -9.5E 0 (0) -3.1 - 1.1)E 2 -9.9 - 7.9)E 1 -1.5 - 1.2)E 2 (0/ 18) (0/ 6) (0/ 12) Th-232 (30) 5.6E 2 52 1.9E 3 1.1E 3 (0) 1.2 - 18.9)E 2 1.0 - 3.6)E 3 -1.9 - 36.3)E 2 (13/ 18) (6/ 6) (9/ 12)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
**The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
41
G) Fish Semiannual fish and invertebrate samples are required from two locations. The Program calls for samples to be collected quarterly from two locations. This section presents the results for fish sampling only. Invertebrate results may be found in sections entitled Lobsters and Shellfish. A CR was generated to document that fish were not collected for the first Quarter. This was due to the lack of fish in the prescribed areas. The contractor Normandeau Associates was unable to collect fish from either the indicator or control locations. Procedural collection steps were met as net towing was attempted for approximately 4 hours at the designated locations. During the year, the fish species collected from station no.03 (indicator station) were Winter and Yellow Tail Flounder. Species collected from station no.53 (control station) were Winter Flounder. A gamma analysis was performed on each sample collected. In 2001, the only radionuclide detected in fish samples was natural occurring K-40. No plant related radionuclides were detected. No increasing or decreasing trend exists. Subsequently, there is no dose to the public or impact to the environment, through this pathway, from plant operations. This is consistent with the last twelve years of plant operations, as well as the preoperational program. 42
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Fish (FH- UNITS: pCI/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected*) (No. Detected**) (No. Detected**) Be-7 (6) -1.2E 1 03 -1.2E 1 -6.OE 1 (0) -3.7 - 0.0)E 1 -3.7 - 0.0)E 1 -1.1 - 0.0)E 2 (0/ 3) (0/ 3) (0/ 3) K-40 (6) 3.5E 3 53 3.7E 3 3.7E 3 (0) ( 3.4 - 3.6)E 3 3.4 - 3.9)E 3 ( 3.4 - 3.9)E 3 (3/ 3) (3/ 3) (3/ 3) 7.9E 1 53 1.4Z 2 1.4E 2 Cr-51 (6) (0) -5.2 - 15.7)E 1 3.5 - 31.0)E 1 ( 3.5 - 31.0)E 1 (0/ 3) (0/ 3) (0/ 3) Mn-54 (6) 130 -4.2E 0 53 -4.2E 0 -4.2E 0
-1.9 - 1.2)E 1 -1.9 - 0.8)E 1 -1.9 - 0.8)E 1 (0)
(0/ 3) (0/ 3) (0/ 3)
-3.1E 0 53 -4.5E -2 -4.5E -2 Co-57 (6)
(0) -7.4 - -0.3)E 0 -4.8 - 9.4)E 0 ( -4.8 - 9.4)E 0 (0/ 3) (0/ 3) (0/ 3) 130 1.5E 0 03 1.5E 0 -2.4E 0 Co-58 (6) (0) -9.0 - 18.2)E 0 -9.0 - 18.2)E 0 -1.1 - 0.7)E 1 (0/ 3) (0/ 3) (0/ 3) Fe-59 (6) 260 1.4E 1 03 1.4AE 1 -3.5E 1 (0) ( -8.4 - 44.6)E 0 -8.4 - 44.6)E 0 -9.7 - 0.O)E 1 (0/ 3) (0/ 3) (0/ 3) Co-60 (6) 130 7.8E 0 53 8.OE 0 8.OE 0 (0) -9.1 - 166.2)E -1 5.7 - 11.9)E 0 ( 5.7 - 11.9)E 0 (0/ 3) (0/ 3) (0/ 3) 260 -3.3E 1 53 -1.8E 1 -1.8E 1 Zn-65 (6) (0) -5.9 - 0.6)E 1 -3.5 - O.O)E 1 -3.5 - 0.0)E 1 (0/ 3) (0/ 3) (0/ 3) Se-75 (6) -8.8E 0 53 -8.3E -1 -8.3E -1
-1.2 - -0.5)E 1 -2.6 - 1.8)E 0 -2.6 - 1.8)E 0 (0)
(0/ 3) (0/ 3) (0/ 3)
-1.4E 1 53 1.7E 1 1.7E 1 Zr-95 (6)
(0) ( -4.0 - 1.0)E 1 6.6 - 262.9)E -1 ( 6.6 - 262.9)E -1 (0/ 3) (0/ 3) (o/ 3) 4.7E 0 03 4.7E 0 2.9E 0 Ru-103 (6) (0) ( -9.9 - 16.8)E 0 -9.9 - 16.8)E 0 ( 2.5 - 3.5)E 0 (0/ 3) (0/ 3) (0/ 3) 43
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Fish (FH) UNITS: oCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected*) (No. Detected*) (No. Detected**) Ru-106 (6) -7.6E I 53 -3.5E 1 -3.5E 1 (0) -1.2 - -0.4)E 2 -1.4 - 0.3)E 2 -1.4 - 0.3)E 2 (0/ 3) (0/ 3) (0/ 3) Ag-110M (6) 1.2E . 03 1.2E 1 -9.2E 0 (0) 0.0 - 1.9)E 1 0.0 - 1.9)E 1 -1.5 - -0.5)E I (0/ 3) (0/ 3) (0/ 3) Sb-124 (6) -1.4E 1 53 1.4E 1 1.4E 1 (0) -2.1 - -1.1)E 1 -1.2 - 6.3)E 1 -1.2 - 6.3)E 1 (0/ 3) (0/ 3) (0/ 3) 1-131 (6) -1.9E 1 53 -6.2E 0 -6.2E 0 (0) -1.2 - 1.0)E 2 -1.3 - 0.7)E 1 -1.3 - 0.7)E 1 (0/ 3) (0/ 3) (0/ 3) Cs-134 (6) 130 1.1E 1 03 1.1E 1 7.9E 0 (0) 6.0 - 17.3)E 0 6.0 - 17.3)E 0 0.0 - 2.3)E 1 (0/ 3) (0/ 3) (0/ 3) Cs-137 (6) 150 -3.4E 0 03 -3.4E 0 -1.3E 1 (0) -8.7 - 2.9)E 0 -8.7 - 2.9)E 0 -1.7 - -0.8)3 1 (0/ 3) (0/ 3) (0/ 3) Ba-1 40 (6) 4.2E 0 53 1.6E 1 1.6E 1 (0) -5.9 - 23.8)E 0 0.0 - 4.1)E 1 0.0 - 4.1)E 1 (0/ 3) (0/ 3) (0/ 3) Ce-141 (6) 1.13 1 03 1.1E 1 -1.6E 0 (0) -3.5 - 210.2)E -1 -3.5 - 210.2)E -1 -2.0 - 2.0)E 1 (0/ 3) (0/ 3) (0/ 3) Ce-1 44 (6) 1.5E 1 03 1.5E 1 -I.5E 1 (0) -3.3 - 6.8)E 1 -3.3 - 6.8)E 1 -3.2 - 0.8)E 1 (0/ 3) (0/ 3) (0/ 3) Th-232 (6) 2.9E 1 03 2.9E 1 -3.1E 1 (0) -2.7 - 10.5)E 1 -2.7 - 10.5)E 1 -6.7 - -0.4)E 1 (0/ 3) (0/ 3) (0/ 3)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
**The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown In parentheses.
44
H) Lobsters Semiannual fish and invertebrate samples were required from two locations. This section provides the results for one type of invertebrate - Homarus americanus (American lobsters). Fish and other invertebrate results may be found in the sections entitled Fish and Shellfish, respectively. Samples were collected from two locations semiannually. During the year, lobsters were collected from an indicator location near the discharge and from a control location within Ipswich Bay. A total of four samples were collected for the year. A gamma analysis was performed on each sample. The only radionuclide detected in lobster samples in 2001 was natural occurring K-40. No plant related radionuclides were detected. Therefore, no increasing or decreasing trend exists. Subsequently, there is no dose to the public or impact to the environment, from this pathway, from plant operations. This is consistent with the last twelve years of plant operations as well as the preoperational program. 45
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: American Lobster (HA) UNITS: pCVkg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected-) (No. Detected*) (No. Detected-) Be-7 (4) 9.1E 0 54 7. 1E 1 7.1E 1 (0) -1.7 - 3.6)E 1 -7.7 - 21.9)E 1 -7.7 - 21.9)E 1 (0/ 2) (0/ 2) (0/ 2) (4) 2.0E 3 04 2.OE 3 1.7E 3 K-40 (0) 1.9 - 2.0)E 3 1.9 - 2.0)E 3 ( 1.4 - 2.0)E 3 (2/ 2) (2/ 2) (2/ 2) 7.2E 0 04 7.2E 0 -5.5E 1 Cr-51 (4) (0) -3.2 - 4.6)E 1 -3.2 - 4.6)E 1 -6.0 - -5.0)E 1 (01 2) (0/ 2) (0/ 2) Mn-54 (4) 130 2.6E 0 04 2.6E 0 -7.7E -1 (0) ( 0.0 - 5.2)E 0 0.0 - 5.2)E 0 -4.0 - 2.4)E 0 (0/ 2) (0/ 2) (0/ 2) Co-57 (4) -9.3E 0 54 -3.9E -2 -3.9E -2 (0) -9.4 - -9.2)E 0 -1.1 - 1.0)E 0 -1.1 - 1.0)E 0 (0/ 2) (0/ 2) (0/ 2) 130 9.3E -1 04 9.3E -1 6.0E -2 Co-58 (4) (0) -5.3 - 7.1)E 0 -5.3 - 7.1)E 0 -1.1 - 1.1)E 1 (0/ 2) (0/ 2) (0/ 2) 260 2.2E -1 04 2.2E -1 -3.4E 1 Fe-59 (4) (0) -4.0 - 4.0)E 1 -4.0 - 4.0)E 1 -4.3 - -2.5)E 1 (0/ 2) (0/ 2) (0/ 2) 130 2.2E 0 54 4.3E 0 4.3E 0 Co-60 (4) (0) -1.9 - 6.2)E 0 -1.5 - 10.2)E 0 -1.5 - 10.2)E 0 (0/ 2) (0/ 2) (0/ 2) Zn-65 (4) 260 -3.0E 1 54 -2.6E 1 -2.6E 1 (0) -6.0 - 0.0)E 1 -5.2 - 0.0)E 1 -5.2 - 0.0)E 1 (0/ 2) (0/ 2) (0/ 2)
-8.9E 04 -8.9E -1 -6.9E 0 Se-75 (4) -1 (0) -1.3 - 1.2)E 1 -1.3 - 1.2)E 1 -7.0 - -6.9)E 0 (0/ 2) (0/ 2) (0/ 2) 1.4E 1 04 1.4E 1 -2.8E 0 Zr-95 (4)
(0) 6.1 - 21.7)E 0 6.1 - 21.7)E 0 -1.0 - 0.4)E 1 (0/ 2) (0/ 2) (0/ 2) 1.4E 1 04 1.4E 1 -1.6E 1 Ru-103 (4) (0) 9.3 - 18.1)E 0 9.3 - 18.1)E 0 -1.8 - -1.4)E 1 (0/ 2) (0/ 2) (0/ 2) 46
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: American Lobster (HA) UNITS: pCI/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected*) (No. Detected-*) (No. Detected**) Ru-106 (4) 1.5E 1 04 1.5E 1 -5.1E 1 (0) -3.7 - 6.7)E 1 -3.7 - 6.7)E 1 -1.2 - 0.2)E 2 (0/ 2) (0/ 2) (0/ 2) Ag-i10M (4) 2.9E 1 04 2.9E 1 8.9E 0 (0) 2.4 - 3.4)E 1 ( 2.4 - 3.4)E 1 0.0 - 1.8)E 1 (0/ 2) (0/ 2) (0/ 2) Sb-1i24 (4) 54 -5.8E 0 -5.8E 0 (0) -2.3 - 0.0)E 1 -1.2 - 0.0)E 1 -1.2 - 0.0)E 1 (0/ 2) (0/ 2) (0/ 2) 1-131 (4) -2.7E 0 54 9.8E 0 9.8E 0 (0) -5.5 - O.0)E 0 ( 3.5 - 16.1)E 0 3.5 - 16.1)E 0 (0/ 2) (0/ 2) (0/ 2) Cs-134 (4) 130 -1.3E 0 54 5.3E 0 5.3E 0 (0) -1.2 - 1.0)E 1 ( 4.7 - 5.9)E 0 4.7 - 5.9)E 0 (0/ 2) (0/ 2) (0/ 2) Cs-137 (4) 150 -1.6E 0 54 -4.5E -1 -4.5E -1 (0) -6.0 - 2.8)E 0 -9.9 - 9.0)E 0 -9.9 - 9.0)E 0 (0/ 2) (0/ 2) (0/ 2) Ba-140 (4) 1.8E 1 54 2.5E 1 2.5E 1 (0) 8.7 - 28.0)E 0 -6.6 - 56.0)E 0 -6.6 - 56.0)E 0 (0/ 2) (0/ 2) (0/ 2) Ce-141 (4) -1.7E 1 54 -1.6E 1 -1.6E 1 (0) -1.8 - -1.6)E 1 -3.2 - 0.0)E 1 -3.2 - 0.0)E 1 (0/ 2) (0/ 2) (0/ 2) Ce-1 44 (4) -1.2E 1 04 -1.2E 1 -2.9E 1 (0) -2.1 - -0.2)E 1 -2.1 - -0.2)E 1 -7.4 - 1.6)E 1 (0/ 2) (0/ 2) (0/ 2) Th-232 (4) 1.5E 1 54 1.6E 1 1.6E 1 (0) ( 4.9 - 25.8)E 0 -1.7 - 4.9)E 1 -1.7 - 4.9)E 1 (0/ 2) (0/ 2) (0/ 2)
- Non-Routine refers to those radlonuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
**The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown In parentheses.
47
I) Shellfish Semiannual fish and invertebrate samples are required from two locations. This section provides the results for shellfish samples only. Fish and other invertebrate results may be found in the sections entitled Fish and Lobsters, respectively. During the year there were two species of mussels harvested for analysis. Modiolus (horse mussels) were collected, by divers, from near the discharge outfall (indicator station) and from Ipswich Bay (control). Mytilus (blue mussels) were collected from the intratidal areas of Seabrook Harbor (indicator) and Plum Island, MA (control). Eight samples were collected for the year. A gamma analysis was performed on each sample. The only radionuclide detected in shellfish samples in 2001 was natural occurring K-40. No plant related radionuclides were detected. Therefore, no increasing or decreasing trend exists. Subsequently, there is no dose to the public or impact to the environment, from this pathway, from plant operations. This is consistent with the preoperational program and with previous years of plant operations. 48
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Mussel (MU) UNITS: pCI/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected*) (No. Detected**) (No. Detected*)
-9.5E 1 56 5.7E 0 -1.5E 1 Be-7 (8)
(0) -1.7 - -0.3)E 2 -1.0 - 1.1)E 2 -1.1 - 1.1)E 2 (0/ 4) (0/ 2) (0/ 4) K-40 (8) 1.2E 3 56 1.7E 3 1.3E 3 (0) ( 8.2 - 13.6)E 2 1.6 - 1.7)E 3 ( 8.3 - 17.1)E 2 (4/ 4) (2/ 2) (4/ 4) Cr-51 (8) -6.9E 1 59 9.9E 1 1.9E 1 (0) -1.6 - 0.2)E 2 0.0 - 2.0)E 2 -8.8 - 19.8)E 1 (0/ 4) (0/ 2) (0/ 4) Mn-54 (8) 130 1.2E 0 09 5.7E 0 1.3E -1 (0) -2.3 - 1.6)E 1 1.5 - 9.9)E 0 -3.2 - 5.6)E 0 (0/ 4) (0/ 2) (0/ 4) Co-57 (8) 2.1E 0 09 5.9E 0 1.3E 0 (0) -8.8 - 10.1)E 0 ( 1.7 - 10.1)E 0 -4.9 - 8.7)E 0 (0/ 4) (0/ 2) (o/ 4) Co-58 (8) 130 -2.5E 0 56 5.8E 0 3.4E 0 (0) -7.3 - 2.3)E 0 -2.4 - 14.1)E 0 -2.4 - 14.1)E 0 (0/ 4) (0/ 2) (0/ 4) Fe-59 (8) 260 -3.6E 1 56 1.8E 1 5.0E 0 (0) -8.8 - -0.9)E 1 3.3 - 32.$)E 0 -1.7 - 3.3)E 1 (0/ 4) (0/ 2) (0/ 4) Co-60 (8) 130 9.4E 0 06 9.7E 0 3.3E 0 (0) -3.8 - 22.2)E 0 4.5 - 14.8)E 0 -3.6 - 13.5)E 0 (0/ 4) (0/ 2) (0/ 4) Zn-65 (8) 260 -2.3E 1 06 -1.5E 1 -2.6E 1 (0) ( -5.0 - 0.6)E 1 -3.6 - 0.6)E 1 -6.8 - 0.7)E 1 (0/ 4) (0/ 2) (0/ 4) Se-75 (8) -3.3E 0 59 5.5E 0 -1.8E 0 (0) -8.0 - 6.2)E 0 ( -2.0 - 12.9)E 0 -1.6 - 1.3)E 1 (D/ 4) (0/ 2) (0/ 4) Zr-95 (8) 2.3E -1 09 3.8E 0 -9.6E -1 (0) -1.4 - 0.8)E 1 ( 3.7 - 4.0)E 0 ( -1.7 - 1.3)E 1 (0/ 4) (0/ 2) (0/ 4) Ru-1i03 (8) -1.6E 0 06 1.1E 0 -1.8E 1 (0) ( -1.2 - 1.4)E 1 -1.2 - 1.4)E 1 ( -3.3 - -0.7)E 1 (0/ 4) (0/ 2) (0/ 4) 49
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Mussel (MU) UNITS: oCilko Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected*) (No. Detected**) (No. Detected**) Ru-106 (8) -6.9E 1 56 7.4E 1 3.5E 1 (0) -1.3 - -0.2)E 2 -3.7 - 18.6)E 1 -3.7 - 18.6)E 1 (0/ 4) (0/ 2) (0/ 4) Ag-110M (8) -1.7E 0 56 1.9E 1 I.0E 1 (0) -1.3 - 0.5)E 1 ( 1.8 - 2.0)E 1 -8.2 - 19.6)E 0 (0/ 4) (0/ 2) (0/ 4) Sb-124 (8) -2.0E 1 56 1.1E 1 5.5E 0 (0) -5.2 - 0.7)E 1 ( 3.5 - 18.4)E 0 ( 0.0 - 1.8)E 1 (0/ 4) (0/ 2) (0/ 4) 1-131 (8) 8.0E 0 56 3.3E 1 2.OE 1 (0) -1.1 - 3.5)E 1 ( 1.4 - 5.3)z 1 ( 0.0 - 5.3)E 1 (0/ 4) (0/ 2) (0/ 4) Cs-134 (8) 130 5.OE 0 59 8.2E 0 8.0E 0 (0) 3.4 - 8.0)E 0 ( 4.6 - 159.5)E -1 ( 4.6 - 159.5)E -1 (0/ 4) (0/ 2) (0/ 4) Cs-137 (8) 150 -5.4E 0 09 3.2E 0 -2.6E 0 (0) -1.6 - 0.6)E 1 ( 9.7 - 55.2)E -1 -2.0 - 1.3)E 1 (0/ 4) (0/ 2) (0/ 4) Ba-1 40 (8) 7.8E 0 09 1.0E 1 -2.1E 1 (0) -1.3 - 2.4)E 1 ( 6.7 - 13.6)E 0 -4.4 - 1.9)E 1 (0/ 4) (0/ 2) (0/ 4) Ce-141 (8) 1.0E 1 09 1.9E 1 -9.1E 0 (0) -1.1 - 3.6)E 1 ( 2.6 - 35.7)E 0 -8.0 - 3.1)E 1 (0/ 4) (0/ 2) (0/ 4) Ce-1 44 (8) -7.4E 0 59 5.6E I 2.7E 1 (0) -4.8 - 4.4)E 1 4.5 - 6.8)E 1 -3.1 - 6.8)E 1 (0/ 4) (0/ 2) (0/ 4) Th-232 (8) 1.6E 1 09 2.7E 1 -1.3E 1
-1.7 - 3.8)E 1 ( 1.7 - 3.8)E 1 -3.0 - 0.4)E 1 (0)
(0/ 4) (0/ 2) (0/ 4)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels In ODCM Table A.5-3.
**The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
50
J) Irish Moss There is no requirement to collect Irish Moss samples. Semiannual Chondrus (Irish Moss) samples were collected from an indicator area near plant discharge and a control location within Ipswich Bay. Four samples were collected for the year. A gamma analysis was performed on each sample. The only radionuclides detected in 2001 were naturally occurring Be-7 and K-40. Potassium 40 was found in all samples analyzed. No plant related radionuclides were detected. Therefore no increasing or decreasing trend exists. Subsequently, there is no dose to the public or impact to the environment, through this pathway, from plant operations. This is consistent with the preoperational program and with previous years of plant operations. 51
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MI=I'hIIM* lIrih MnP* IAI) [INITq." nCilka "fiEDIUmm Irish mn Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine) LLD (No. Detected-) (No. Detected**) (No. Detected*) Be-7 (4) 1.6E 1 55 3.3E 1 3.3E 1 3.2 - 28.9)E 0 2.3 - 4.3)E 1 2.3 - 4.3)E 1 (0) (0/ 2) (0/ 2) (0/ 2) 7.2E 3 05 7.2E 3 4.BE 3 K-40 (4) ( 6.8 - 7.5)E 3 6.8 - 7.5)E 3 3.9 - 5.8)E 3 (0) (2/ 2) (2/ 2) (2/ 2)
-4.13 1 55 -2.4E 1 -2.4E 1 Cr-51 (4) -6.5 -1.6)E 1 1 -2.6 - -2.2)E 1 -2.6 - -2.2)E 1 (0) -
(0/ 2) (0/ 2) (0/ 2)
-2.5E 0 55 1.9E 0 1.9E 0 Mn-54 (4) -6.7 - 1.7)E 0 1.3 - 2.6)E 0 1.3 - 2.6)E 0 (0)
(0/ 2) (0/ 2) (0/ 2) 2.1E 0 05 2.1E 0 3.7E -1 Co-57 (4)
-7.0 - 48.2)E -1 -7.0 - 48.2)E -1 -6.1 - 13.6)E -1 (0)
(0/ 2) (0/ 2) (0/ 2) 5.4E -1 05 5.4E -1 -5.7E 0 Co-58 (4)
-3.1 - 4.2)E 0 -3.1 - 4.2)E 0 -7.9 - -3.5)E 0 (0)
(0/ 2) (0/ 2) (0/ 2) 1.5E 0 55 7.8E 0 7.8E 0 Fe-59 (4)
-3.8 - 4.1)E 1 2.0 - 13.6)E 0 2.0 - 13.6)E 0 (0)
(0/ 2) (0/ 2) (0/ 2)
-8.6E 0 55 4.7E 0 4.7E 0 Co-60 (4) -1.3 - -0.4)E 1 4.5 - 4.9)E 0 4.5 - 4.9)E 0 (0)
(0/ 2) (0/ 2) (0/ 2)
-2.7E 1 55 -1.5E 1 -1.5E 1 Zn-65 (4) -5.4 - 0.0)E 1 -1.9 - -1.1)E 1 -1.9 - -1.1)E 1 (0)
(0/ 2) (0/ 2) (0/ 2)
-2.8E 0 55 2.4E 0 2.4E 0 Se-75 (4) -6.9 - 1.3)E 0 ( 1.4 - 3.4)E 0 1.4 - 3.4)E 0 (0)
(0/ 2) (0/ 2) (0/ 2)
-1.2E 1 55 -5.3E 0 -5.3E 0 Zr-95 (4) -1.9 - -0.4)E 1 -7.3 - -3.3)E 0 -7.3 - -3.3)E 0 (0)
(0/ 2) (0/ 2) (0/ 2) 7.7E 0 05 7.7E 0 -2.9E 0 Ru-103 (4) ( 7.4 - 8.1)E 0 7.4 - 8.1)E 0 -4.9 - -0.9)E 0 (0) (0/ 2) (0/ 2) (0/ 2)
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Irish Moss (AL) UNITS: pCI/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected-) (No. Detected**) (No. Detected-) Ru-106 (4) -5.9E 1 55 -2.0E 1 -2.OE 1 (0) -1.4 - 0.2)E 2 -5.5 - 1.6)E 1 -5.5 - 1.6)E 1 (0/ 2) (0/ 2) (0/ 2) Ag-110M (4) 5.2E 0 05 5.2E 0 -9.OE 0 (0) -1.9 - 12.3)E 0 -1.9 - 12.3)E 0 -1.1 - -0.8)E 1 (0/ 2) (0/ 2) (0/ 2) Sb-124 (4) 9.2E 0 05 9.2E 0 8.9E 0 (0) -1.6 - 19.9)E 0 -1.6 - 19.9)E 0 ( 4.5 - 13.4)E 0 (0/ 2) (0/ 2) (0/ 2) 1-131 (4) -1.3E 1 05 -1.3E 1 -1.7E 1 (0) -2.6 - 0.0)E 1 -2.6 - 0.0)E 1 -3.1 - -0.3)E 1 (0/ 2) (0/ 2) (0/ 2) Cs-1 34 (4) -5.4E 0 55 2.3E 0 2.3E 0 (0) -9.1 - -1.7)E 0 ( 2.0 - 2.6)E 0 2.0 - 2.6)E 0 (0/ 2) (0/ 2) (0/ 2) Cs-137 (4) 2.6E 0 05 2.6E 0 -3.4E 0 (0) 0.0 - 5.1)E 0 0.0 - 5.1)E 0 -5.2 - -1.5)E 0 (0/ 2) (0/ 2) (0/ 2) Ba-140 (4) -3.0E 1 55 6.7E 0 6.7E 0 (0) -6.3 - 0.3)E 1 ( 0.0 - 1.3)E 1 0.0 - 1.3)E 1 (0/ 2) (0/ 2) (0/ 2) Ce-141 (4) 1.1E 0 05 1.1E 0 -4.9E 0 ( 1.1 - 1.1)E 0 (1.1 -1.1)E 0 -5.0 - -4.7)E 0 (0) (0/ 2) (0/ 2) (0/ 2) Ce-1 44 (4) -1.1E 1 55 -7.1E 0 -7.1E 0 (0) -2.1 - -O.1)E 1 -1.9 - 0.5)E 1 -1.9 - 0.5)E 1 (0/ 2) (0/ 2) (0/ 2) Th-232 (4) -1.6E 1 55 1.4E 1 1.4E 1 (0) -4.5 - 1.4)E 1 -3.7 - 31.0)E 0 -3.7 - 31.0)E 0 (0/ 2) (0/ 2) (0/ 2)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
** The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
53
K) Food Crop There is no requirement for food crop samples as long as the required milk locations are available. Samples were collected from three to four locations in the growing season months. Strawberries (June), green beans (July), and corn (August) were collected. For the year, a total of nine samples were collected. A CR was generated to reflect a name change to one of the farms where food crops are collected. This CR also addressed the issue of utilizing a scale that is more user friendly regarding alignment and calibration. A gamma analysis was performed on each sample. The only radionuclide detected in 2001 was natural occurring K-40. Potassium 40 was detected at all locations both indicator and control for the three months sampled. Potassium 40 was not detected at the control station for the June time period. No plant related radionuclides were detected. Therefore, no increasing or decreasing trend exists. Subsequently, there is no dose to the public or impact on the environment, through this pathway, from plant operations. This is consistent with the preoperational program and with previous years of plant operations. 54
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Food Crop (TF) UNITS: pCI/ka Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine*) LLD (No. Detected**) (No. Detected**) (No. Detected*) Be-7 (9) -1.3E 1 02 -1.2E 1 -5.5E 1 (0) -3.8 - 1.7)E 1 -3.7 - O.0)E 1 -1.0 - 0.0)E 2 (0/ 6) (0/ 3) (0/ 3) K-40 (9) 2.OE 3 02 2.4E 3 1.6E 3 (0) ( 1.1 - 2.7)E 3 ( 1.7 - 2.7)E 3 1.1 - 2.0)E 3 (6/ 6) (3/ 3) (3/ 3) Cr-51 (9) -1.3E 1 03 5.2E 1 -1.2E 1 (0) -2.0 - 1.7)E 2 -4.5 - 16.7)E 1 ( -1.0 - 0.7)E 2 (0/ 6) (0/ 3) (0/ 3) Mn-54 (9) -5.9E 0 03 6.2E 0 2.3E 0 (0) -2.0 - 1.4)E 1 -6.0 - 14.1)E 0 -2.8 - 7.0)E 0 (0/ 6) (0/ 3) (01 3) Co-57 (9) 4.2E 0 02 1.2E 1 -5.6E 0 (0) -6.8 - 25.1)E 0 ( 0.0 - 2.5)E 1 -9.8 - -0.8)E 0 (0/ 6) (0/ 3) (0/ 3) Co-58 (9) 2.4E 0 03 8.0E 0 4.1E 0 (0) -7.2 - 21.1)E 0 -2.8 - 21.1)E 0 -1.1 - 2.1)E 1 (0/ 6) (0/ 3) (0/ 3) Fe-59 (9) 2.8E 0 02 3.2E 1 2.8E 0 (0) -9.5 - 5.1)E 1 1.4 - 5.1)E 1 -2.6 - 2.0)E 1 (0/ 6) (0/ 3) (0/ 3) Co-60 (9) -1.6E 0 03 8.OE 0 -9.7E 0 (0) -2.0 - 2.5)E 1 -1.5 - 2.5)E 1 -2.6 - 0.1)E 1 (0/ 6) (0/ 3) (0/ 3) Zn-65 (9) -1.OE 1 02 -8.5E 0 -2.OE 1 (0) -3.6 - 0.7)E 1 -1.8 - 0.6)E 1 -7.1 - 3.0)E 1 (0/ 6) (0/ 3) (0/ 3) Se-75 (9) -l.1E 0 03 4.7E 0 -3.6E 0
-1.9 - 0.8)E 1 0.0 - 7.6)E 0 -1.1 - 0.7)E 1 (0)
(0/ 6) (0/ 3) (0/ 3) Zr-95 (9) 5.6E 0 03 1.3E 1 -9.7E 0 (0) -3.4 - 3.1)E 1 ( 0.0 - 3.1)E 1 ( -1.8 - -0.3)E 1 (0/ 6) (0/ 3) (0/ 3) Ru-103 (9) -5.1E -1 03 -2.5E -1 -3.4E 0 (0) -1.3 - 1.7)E 1 -1.3 - 1.7)E 1 ( -6.7 - 0.0)E 0 (0/ 6) (0/ 3) (0/ 3) 55
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 2001) MEDIUM: Food Crop (TF) UNITS: pCI/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine) LLD (No. Detected*) (No. Detected*) (No. Detected*) Ru-106 (9) -6.5E 1 02 -5.OE 1 -1.1E 2 (0) -1.1 - 0.5)E 2 -1.1 - 0.5)E 2 -2.0 - 0.6)E 2 (0/ 6) (0/ 3) (0/ 3) Ag-110M (9) -4.3E 0 02 2.1E 0 -1.0E 1 (0) -3.4 - 1.6)E 1 -1.1 - 1.6)E 1 -1.6 - -0.4)E 1 (0/ 6) (0/ 3) (0/ 3) Sb-124 (9) 1.7E 1 02 1.8E 1 -2.7E -1 (0) ( -2.5 - 5.4)E 1 -2.0 - 5.4)E 1 -2.5 - 3.3)E 1 (0/ 6) (0/ 3) (0/ 3) 1-131 (9) 60 1.4E 1 02 2.1E 1 -1.8E 1 (0) 0.0 - 3.2)E 1 0.0 - 3.2)E 1 -3.9 - 0.5)E 1 (0/ 6) (0/ 3) (0/ 3) Cs-134 (9) 60 6.2E 0 03 1.3E 1 5.0E 0 (0) -2.2 - 2.0)E 1 1.2 - 19.9)E 0 -1.4 - 1.6)E 1 (0/ 6) (0/ 3) (0/ 3) Cs-137 (9) 80 -4.1E 0 02 -2.0Z 0 -6.93 0
-2.1 - 0.6)E 1 -9.6 - 5.5)E 0 -1.9 - 0.6)E 1 (0)
(0/ 6) (0/ 3) (0/ 3) Ba-140 (9) 6.8E 0 02 2.3E 1 -1.3E 1 (0) -4.5 - 3.2)E 1 1.5 - 3.2)E 1 -5.2 - 0.9)E 1 (o/ 6) (0/ 3) (0/' 3) Ce-141 (9) 6.4E 0 02 1.1E 1 9.0E 0 (0) -1.4 - 1.9)E 1 8.4 - 14.0)E 0 0.0 - 2.0)E 1 (0/ 6) (0/ 3) (0/ 3) Ce-144 (9) 1.3E -2 06 2.9E 1 2.9E 1 (0) -6.3 - 2.5)E 1 7.7 - 46.9)E 0 7.7 - 46.9)E 0 (0/ 6) (0/ 3) (0/ 3) Th-232 (9) 1.2E 1 03 1.2E 1 4.4E -1 (0) -1.7 - 3.5)E 1 -1.7 - 3.5)E 1 -1.7 - 1.5)E 1 (0/ 6) (0/ 3) (0/ 3) Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
** The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) Is shown in parentheses.
56
L) Direct Radiation Direct gamma radiation exposure was measured with thermoluminescent dosimeters (TLDs). Two Panasonic UD-814 TLD badges are placed at each of the monitoring stations. Each TLD badge has 3 CaSO4 :Tm elements. A location result is an average of six independent readings per quarter. A total of forty-seven stations are located offsite, forty of which are required. The badges were collected and readout on a quarterly schedule. The exposure rates were normalized to a 91-day quarter. A summary of the data is shown in Table 3.1. Overall, the REMP direct radiation program showed no indication of increased direct radiation above background either within the owner-controlled area or beyond the site boundary. This is demonstrated by the fact that indicator location results are statistically identical to control locations. The annual mean of all indicator locations was 16.2 mrem while the mean of all control locations was 17.4 mrem. This verifies that there is no difference in the annual dose as a function of distance from the plant. The 2001 TLD direct radiation program, when compared to the previous years of operational data and the pre-operational program, shows no significant trends relative to increased dose rates in the environment. A CR was generated in January 2001 for a missing TLD (badge #23) that was part of the 2000 fourth quarter change out. The local utility company (where the TLD was located) unintentionally destroyed the badge when it replaced the utility pole where the badge was located. No further corrective actions were implemented. The direct radiation-monitoring program demonstrated that there was no offsite dose to the public or impact to the environment from the operation of the plant. 57
TABLE 3.1 Environmental TLD Measurements Net Exposure in mR/Standard Quarter (91 days) 2001 Annual Sta. 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Ave. No. Description EXp. S.D. Exo. S.D. EXV. S.D. EXp. S.D. Exp. TL-01 BrimmerIs Lane 13.0 +/- 0.6 15.5 +/- 0.6 17.4 + 1.0 16.3 + 0.7 15.6 TL-02 Landing Road 12.9 +/- 0.7 13.8 + 0.7 15.1 + 0.5 15.0 +/- 0.9 14.2 TL-03 Glade Path 15.2 +/- 0.7 14.7 + 0.7 16.5 + 0.7 15.9 +/- 0.6 15.6 TL-04 Island Path 14.0 +/- 0.6 14.6 + 0.5 16.4 + 0.7 16.1 + 0.6 15.3 TL-05 Harbor Road 14.8 +/- 0.6 15.4 +/- 0.7 17.0 +/- 0.8 16.4 +/- 0.7 15.9 TL-06 Barge Landing 12.7 +/- 0.6 14.3 +/- 0.6 15.4 +/- 0.6 15.1 +/- 0.7 14.4 TL-07 Cross Road 12.5 +/- 0.6 12.7 +/- 0.7 14.1 +/- 0.8 13.7 +/- 0.8 13.3 TL-08 Farm Lane 14.1 +/- 0.7 14.4 +/- 0.6 17.2 +/- 0.8 16.0 +/- 0.7 15.4 TL-09 Farm Lane 15.1 +/- 0.7 16.1 +/- 0.6 18.4 + 0.7 17.0 +/- 0.8 16.7 TL-10 Site Boundary 13.5 +/- 0.8 17.8 +/- 0.7 19.3 +/- 0.8 18.1 +/- 1.3 17.2 TL-11 Site Boundary 11.6 + 0.6 14.1 + 0.5 15.5 +/- 0.7 14.5 + 0.6 13.9 TL-12 Site Boundary 15.0 + 0.7 18.4 +/- 0.6 20.3 +/- 0.7 19.1 +/- 0.9 18.2 TL-13 Inside Site Boundary 18.5 + 1.0 19.5 +/- 0.9 21.3 +/- 0.9 20.3 +/- 1.2 19.9 TL-14 Trailer Park 13.9 +/- 0.9 14.8 +/- 0.4 17.0 + 0.6 16.3 + 0.6 15.5 TL-15 Brimmer's Lane 13.0 +/- 0.7 15.1 +/- 0.7 19.0 +/- 1.1 18.1 +/- 0.9 16.3 TL-16 Brimmer's Lane 12.7 +/- 0.8 13.6 + 0.4 15.5 +/- 0.6 14.7 +/- 0.7 14.1 TL-17 South Road 12.4 + 0. 6 15.2 +/- 0.6 17.3 +/- 0.8 16.1 + 0.6 15.3 TL-18 Mill Road 12.2 +/- 0.5 14.7 + 0.4 17.0 +/- 0.7 16.2 +/- 0.7 15.0 TL-19 Appledore Avenue 14.7 + 0.6 14.9 +/- 0.6 16.9 +/- 0.6 16.9 +/- 1.8 15.9 TL-20 Ashworth Avenue 17.8 +/- 0.7 18.7 +/- 0.5 20.0 +/- 0.9 19.1 +/- 0.9 18.9 TL-21 Route 1A 14.8 + 0.7 16.1 + 0.6 17.4 +/- 0.6 17.2 +/- 0.8 16.4 TL-22 Cable Avenue 15.6 +/- 0.7 16.0 +/- 0.8 17.7 +/- 0.9 16.7 +/- 0.7 16.5 TL-23 Ferry Road 14.0 +/- 0.7 15.1 +/- 0.6 17.0 +/- 0.8 16.8 +/- 0.7 15.7 TL-24 Ferry Lots Lane 13.8 +/- 0.7 15.2 + 0.5 17.9 +/- 0.9 17.0 + 0.6 16.0 TL-25 Elm Street 16.0 + 1.3 16.2 +/- 1.0 17.7 + 1.0 17.1 +/- 0.8 16.8 TL-26 Route 107A 14.1 +/- 0.7 17.1 + 0.5 18.8 +/- 0.7 17.6 + 0.7 16.9 TL-27 Highland Street 14.3 +/- 0.7 16.2 + 0.6 17.2 +/- 0.9 15.8 + 0.8 15.9 TL-28 Route 150 14.0 + 0.7 17.0 + 0.9 18.1 + 0.7 17.7 +/- 0.7 16.7 TL-29 Frying Pan Lane 13.8 +/- 0.7 16.2 +/- 0.6 17.6 +/- 0.7 16.4 +/- 0.8 16.0 TL-30 Route 27 12.4 +/- 1.3 16.0 : 0.5 17.9 + 0.7 17.0 +/- 0.6 15.8 TL-31 Alumni Drive 11.4 +/- 0.8 15.0 + 0.8 17.2 + 2.6 15.5 + 0.9 14.8 TL-32 SB Elementary School 16.6 +/- 0.8 17.9 + 1.0 19.6 + 0.7 18.1 + 0.7 18.1 TL-33 Dock Area 17.5 +/- 1.1 18.5 +/- 0.8 19.6 + 1.0 18.6 + 0.7 18.6 TL-34 Bow Street 17.8 +/- 1.0 20.1 +/- 1.0 21.6 + 1.1 20.0 +/- 0.8 19.9 TL-35 Lincoln Ack. School 15.7 +/- 0.9 19.2 +/- 0.6 20.3 : 0.9 19.0 +/- 0.9 18.6 TL-36 Route 97(Control) 15.8 +/- 0.9 17.1 +/- 0.6 18.0 +/- 0.9 17.1 + 0.9 17.0 TL-37 Plaistow, NH (Control) 15.4 +/- 0.9 18.6 +/- 0.8 20.5 +/- 1.2 18.3 +/- 0.6 18.2 TL-38 Hampstead, NH (Control) 16.5 +/- 0.8 20.7 + 0.7 22.3 +/- 1.2 20.1 +/- 0.8 19.9 TL-39 Fremont, NH (Control) 16.8 +/- 0.8 18.9 +/- 0.9 21.5 + 0.9 19.4 + 0.9 19.2 TL-40 Newmarket, NH (Control) 13.0 + 1.0 17 7 + 0.6 20.2 +/- 1.1 17.4 + 0.8 17.1 58
TABLE 3.1 Environmental TLD Measurements Net Exposure in mR/Standard Quarter (91 days) 2001 Annual Sta. 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Ave. No. Description EXp. S.D. ExP. S.D. Exp. S.D. Exp. S.D. Exnp. TL-41 Portsmouth, NH (Control) 15.0 + 0.7 15.9 _+ 0.6 17.3 + 0.8 16.0 + 0.6 16.1
+ 1.0 14.6 + 0.5 15.3 + 0.7 14.6 + 0.6 14.7 TL-42 Ipswich, MA (Control) 14.3 + 0.7 14.6 + 0.5 16.0 + 0.7 14.6 + 0.6 14.5 TL-43 Rocks Road Landing 12.8 + + + 0.5 16.7 0.8 15.1 + 0.6 15.0 TL-44 SB Education Center 13.3 1.2 15.0 + + 18.2 + 0.8 19.3 0.8 17.9 + 0.8 17.9 TL-45 Hampton Fire Station 16.3 0.9 +
16.5 + 1.1 17.7 + 0.6 18.4 0.8 16.7 + 0.8 17.3 TL-46 SB Police Station +
+ 16.7 + 0.9 17.5 0.7 16.2 + 0.7 15.9 TL-47 Route 84 13.3 0.6 Mean of Indicators 14.3 16.1 17.8 16.8 16.2 Mean of Controls 15.3 17.6 19.3 17.6 17.4 59
FIGURE 3.6 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 L... 20 20 E 10 10 0 Qtr. 1 Qtr. 2 Qtr. 3 Qtr. 4 2001
--- TL-01 Brimmer's Lane e----TL-02 Landing Road --A-. TL-03 Glade Path -- TL-04 Island Path ---- TL-05 Harbor Road 60
FIGURE 3.6.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 220 20 (D E 10 10 0 ....... 0 1986 1988 1990 1992 1994 1996 1998 2000 2002 E3 TL-01 Brimmer's Lane
-*--TL-02 Landing Road -*-TL-03 Glade Path TL-04 Island Path --x--TL-05 Harbor Road 61
FIGURE 3.7 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 c. 020 20 E 10- 10 0 -0 Qtr-1 Qtr-2 Qtr-3 Qtr-4 2001
-B--TL-06 Barge Landing -e--TL-07 Cross Road -*-TL-08 Farm Lane -e--TL-09 Farm Lane -- TL-10 Site Boundary 62
FIGURE 3.7.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 30 30 c 20 20 20 2 "E 10- 10 18198 19192 19 96199 200100 10 1 20 Retrieval Date E3- TL-06 Barge Landing e6 TL-07 Cross Road
--A--- TL-08 Farm Lane -e-TL-09Farm Lane -x-TL-10 Site Boundary 63
FIGURE 3.8 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 c 020 -- 20 E ... 10 10 0 - -0 Qtr. I Qtr. 2 Qtr. 3 Qtr. 4 2001 E-B-TL-1 I Site Boundary
--e--TL-12 Site Boundary 6 TL-13 Inside Site Boundary --- TL-14 Trailer Park -x-TL-15 Brimmer's Lane 64
FIGURE 3.8.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 t 020 20 CL E 10 10 1986 1988 1990 1992 1994 1996 1998 2000 2002
-E- TL-1 1 Site Boundary -- TL-12 Site Boundary A TL-13 Inside Site Boundary -o-TL-14 Trailer Park x TL-15 Brimmer's Lane 65
FIGURE 3.9 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 220 -- 20 (D ry E 10 10 0 0 Qtr. 1 Qtr. 2 Qtr. 3 Qtr. 4 2001
-B-TL-16 Brimmer's Lane -G--TL-17 South Road
- TL-18 Mill Road
-*-TL-19 Appledore Avenue -i-TL-20 Ashworth Avenue 66
FIGURE 3.9.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 cu 20 20 E 10 10 0... 0 1986 1988 1990 1992 1994 1996 1998 2000 2002
-E- TL-16 Brimmers Lane -o-- TL-17 South Road - -- TL-1 8 Mill Road --o- TL-1 9 Appiedore Avenue --x--TL-20 Ashworth Avenue 67
FIGURE 3.10 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40- 40 30 30 20 20 a) E 10 10 0 0 Qtr. 1 Qtr. 2 Qtr. 3 Qtr. 4 2001
--- TL-21 Route 1A -e--TL-22 Cable Avenue -A-TL-23 Ferry Road 0 TL-24 Ferry Lots Lane -X--TL-25 Elm Street 68
FIGURE 3.10.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40- 40 30 30 "If O20 20 00. E 10 10 0 11 11112 0 1986 1988 1990 1992 1994 1996 1998 2000 2002
-- 3TL-21 Route 1A -G-- TL-22 Cable Avenue --A- TL-23 Ferry Road -o-- TL-24 Ferry Lots Lane -x-- TL-25 Elm Street 69
FIGURE 3.11 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 c 220 20 i._ E 10 10 0 4 0 Qtr. 1 Qtr. 2 Qtr. 3 Qtr. 4 2001
-B-- TL-26 Route 107A -*-- TL-27 Highland Street ---A-- TL-28 Route 150 -o--TL-29 Frying Pan Lane -x-TL-30 Route 27 70
FIGURE 3.11.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40- 40 30 30 cu 20 -20 E 10 10 019 11199 2 0 1986 1988 1990 1992 1994 1996 1998 2000 2002
-E- TL-26 Route 107A - TL-27 Highland Street ---A-. TL-28 Route 150 -o-TL-29 Frying Pan Lane -x- TL-30 Route 27 71
FIGURE 3.12 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 Cu
~20- 20 U,
E 10 10 Qtr. 1 Qtr. 2 Qtr. 3 Qtr. 4 2001
-B--TL-31 Alumni Drive -e-TL-32 SB Elementarty School
- TL-33 Dock Area
-TL-34 Bow Street -x-TL-35 Lincoln Ackerman School 72
FIGURE 3.12.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 cc S20 -20 CL E 10 10
- 0. 0 1986 1988 1990 1992 1994 1996 1998 2000 2002
--B-TL-31 Alumni Drive -e-TL-32 SB Elementary School
- TL-33 Dock Area
- TL-34 Bow Street -X--TL-35 Lincoln Ackerman School 73
FIGURE 3.13 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40- 40 30 30
-20 ca0 20-E 10 10 0 *0 Qtr. 1 Qtr. 2 Qtr. 3 Qtr. 4 2001 -a-TL-36 Route 97 (Control) -e--TL-37 Plaistow, NH (Control) --- TL-38 Hampstead NH (Control) -*-TL-39 Fremont, NH (Control) -*X--TL-40 Newmarket, NH (Control) 74
FIGURE 3.13.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 u. a) O 20 -'-.i* , 20 E , 10 10 0 ... 0 1986 1988 1990 1992 1994 1996 1998 2000 2002
-- 3 TL-36 Route 97 (Control) - TL-37 Plaistow, NH (Control) ,&-TL-38 Hampstead NH (Control) -- o-TL-39 Fremont, NH (Control) -x- TL-40 Newmarket, NH (Control) 75
FIGURE 3.14 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 O20 20 E 10- 10 0- 0 Qtr. 1 Qtr. 2 Qtr. 3 Qtr. 4 2001
-E-TL-41 Portsmouth, NH (Control) -e-TL-42 Ipswich, MA (Control) -- TL-43 Rocks Road Landing -e- TL-44 SB Education Center -*-TL-45 Hampton Fire Station -*- TL-46 SB Beach Police Station -- *--TL-47 Hampton Falls, Route 84 76
FIGURE 3.14.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 30 0) 0 20 20 CL. E 10 10 0 9 1111 12 0 1986 1988 1990 1992 1994 1996 1998 2000 2002
-E--TL-41 Portsmouth, NH (Control)
TL-42 Ipswich, MA (Control)
---A--TL-43 Rocks Road Landing TL-44 SB Education Center -x---TL-45 Hampton Fire Station -.- TL-46 SB Beach Police Station TL-47 Hampton Falls, Route 84 77
4.0 Quality Assurance Program The quality assurance program at the Duke Engineering & Services Environmental Laboratory is designed to serve two overall purposes:
- 1) Establish a level of confidence in the measurement process to assure the licensee, regulatory agencies and the public that analytical results are accurate and precise; and 2) Identify deficiencies in the sampling or the measurement process to those responsible for these operations so that corrective actions can be taken. Quality assurance is applied to all steps of the measurement process, including the collection, reduction, evaluation and the reporting of data, as well as the record keeping of the final results. Quality control, as part of the quality assurance program, provides a means to control and measure the characteristics of measurement equipment and processes, relative to established requirements.
The DESEL employs a comprehensive program to monitor the quality of analytical processing to ensure reliable environmental monitoring data. The program includes the use of approved and controlled procedures for all work activities, a nonconformance and corrective action tracking program, systematic internal audits, audits by external groups, a laboratory quality control program, and a staff training and retraining program. Monitoring programs include the Intralaboratory Quality Control Program administered by the Laboratory QA Officer (used in conjunction with National Institute Standards and Technology's Measurement Assurance Program, NIST MAP) and the third party interlaboratory programs administered by the US EPA and Analytics, Inc. These programs are targeted to supply QC\QA sources at 5% of the routine sample analysis load. In addition, the Laboratory Quality Control Audit Committee administers and approves a blind duplicate quality assurance program conducted through client environmental monitoring programs. Environmental TLD Program The Panasonic environmental dosimeters are processed by the DESEL, which is a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory. The NVLAP is conducted through the Battelle Pacific Northwest Laboratories. The DESEL environmental TLD program has its own quality assurance program, through the Laboratory Quality Assurance Officer, as well as the NVLAP program. Under these programs, dosimeters are irradiated to ANSI specified testing criteria and submitted for processing to the Dosimetry Services Group as "unknowns". The bias and precision of TLD processing is measured against this standard and is used to indicate trends and changes in performance. Instrument checks, although routinely performed by the Dosimetry Services Group and representing between 5-10% of the TLD's processed, are not part of this report because they do not represent a true process check sample since the doses are known. The DESEL and the third party tester conducted eighty-four independent performance tests in 2001. Of these, 60 TLD's were submitted to the Dosimetry Services Group and 24 were submitted to the Battelle Pacific Northwest Laboratories testing program. The TLD's met the acceptance criteria for bias (+/- 20.1%) and precision (+/- 12.8%). Test Number of Bias % +/- Precision Organization Dosimeters (Std. Dev) % (Std Dev)% Tested Third Party 24 2.7 +/- 5.3 1.1 DESEL 60 0.9 +/- 3.3 1.4 All irradiation's made to Category IV (Cs-137) 78
Intralaboratory Quality Control Program The DESEL conducts an extensive intralaboratory quality control program to assure the validity and reliability of the data. This program includes quality control of laboratory equipment, use of reference standards for calibration, and analysis of blank and spiked samples. Process check samples are either samples submitted in duplicate to evaluate the precision of the measurement or spiked with a known quantity of radioactive material to assess the bias in the measurement. The Laboratory QA Officer reviews the records of the quality control program. Corrective measures are taken whenever applicable. Summaries of the program process check results are found in Table 4.1. Of the 290 analyses, 97.9% passed the bias criteria and 100% of the results evaluated for precision were acceptable. Third Party Intercomparison Program The DESEL participates in a third party cross check program managed by Analytics Inc. to satisfy the requirement of the Environmental Technical Specification/ODCM. The DESEL Analytics program was originally used to augment the EPA Intercomparison Program that it now replaces. The current program is designed to be comparable to the pre-1996 EPA PE Program in terms of the number of samples, matrices and nuclides. The results for the 4 th quarter 2000 through the 3 rd quarter 2001 are summarized in Table 4.2. Each sample is analyzed in triplicate and the results are evaluated against the internal acceptance criteria described in the DESEL Manual 100-Laboratory Quality Assurance Plan. This acceptance protocol is used for all inter-laboratory programs with no pre-set acceptance criteria. When results fall outside of the acceptance criteria, an investigation is initiated to determine the cause of the problem and if appropriate, corrective measures are taken. The DESEL internal acceptance criteria are summarized at the end of Table 7.2. During this reporting period, 96.5% passed the bias criteria and 99.2% passed the criteria for precision. There were three DESEL Condition Reports (CR's) for third party intercomparison "Analytics Inc" that were described in the 2000 Report, they are: DESEL CR 00 a non-agreement for gross alpha/radium in water was a sample preparation issue; DESEL CR 00 Non-agreement for Cr-521 in milk was due to poor counting statistics; DESEL CR 01 Non-agreement for 1-131 in milk involved sample control; All the above issues have been addressed and closed out. In 2001, three Analytics results fell outside the 'agreement' category. Three CR's were issued. DESEL CR 01-07 A non-agreement for Sr-89 on a filter. This CR has been closed out; DESEL CR 01-41 Np-237 in a water sample fell outside the acceptance criteria for bias. Prior residual contamination was the cause for the high sample bias; DESEL CR 02-01 Acceptance criteria exceeded for Sr-89 in milk. Evaluation is pending and will be reported in the 2002 submittal. 79
Blind Duplicate Quality Assurance Program The Laboratory Quality Control Audit Committee (LQCAC) is comprised of representatives from several New England DESEL clients. Two of the primary functions of the LQCAC have been to conduct an annual audit of Laboratory operations and to coordinate the Blind Duplicate Quality Assurance Program. Under the Blind Duplicate Quality Assurance Program, samples are split from homogeneous environmental media by the client and sent to the DESEL for analysis. They are "blind" in that the identification of the matching sample is not identified to the Laboratory. Participating clients submitted a total of 31 paired samples in 2001. The measurements evaluated include twenty-five gamma emitting radionuclides, H-3, Sr-89, Sr-90, 1-131 and gross-beta. All measurements are evaluated, whether the results are statistically positive or not, and whether the net concentration is positive or negative. The samples submitted as part of this program are listed in Table 4.3. Table 4.4 presents the results of the Blind Duplicate Program by analysis type for each participating company. For the 2001 program, 99.4% of the measurements met the DESEL internal acceptance criteria as specified in reference #3. The number of paired references falling outside the acceptance criteria are listed before the dash (/) in each company column. Totals are presented for each participating company as well as the entire program. 80
TABLE 4.1
SUMMARY
OF PROCESS CONTROL ANALYSES RESULTS IN THE INTRALABORATORY PROCESS CONTROL PROGRAM JANUARY-DECEMBER 2001 Media Bias Criteria (1) Precision Criteria (2) Analysis 1 2 3 4 1 2 3 4 I. Air Charcoal Gamma 36 5 0 0 0 0 0 0 II. Air Filter Alpha Beta 100 2 0 0 0 0 0 0 Gamma III. Milk Gamma Iodine-LL 7 3 0 0 15 0 0 0 Strontium-89 0 1 9 0 8 2 0 0 Strontium-90 6 3 1 0 7 3 0 0 IV. Water Gross Alpha 7 6 17 3 4 1 0 0 Gross Beta 25 5 10 3 5 0 0 0 Gamma 0 0 0 0 6 4 6 0 Iodine-LL Radium 226 11 7 2 0 15 4 1 0 Radium-228 3 1 2 0 3 0 2 0 Tritium 4 1 0 0 0 0 0 0 V. Sediment/Soil Gamma Radium-226 VI. Vegetation Gamma Total Number in 199 40 45 6 63 14 9 0 Range Sum of Analyses 290 86 (1) Percent Bias Criteria by Category (2) Percent Precision by Category Bias Category 1 > 0% & </= 5% Precision Category 1> 0% & </= 5% Bias Category 2 > 5% & </=10% Precision Category 2 > 5% & </=10% Bias Category 3 > 10% & </= 15% Precision Category 3 >10% & </=15% Gross alpha, Sr89/90 >10% & </=25% Gross alpha, Sr89/90 >10% & </=25% TRU >10% & </= 20% TRU >10 % & </=20% Bias Category 4 = OUTSIDE CRITERIA Precision Category = OUTSIDE CRITERIA 81
TABLE 4.2 DESEL RESULTS IN THE ANALYTICS INC. CROSS CHECK PROGRAM Quarter 4, 2000 - Quarter 3, 2001 Sample Quarter Sample Nuclide Reported Known Ratio Evaluation Year Media Value* Value
- DESEL/
E2477-162 4"'00 Filter I Sr-89 60 ________Analytics4 85 0.70 Non agreement Sr-90 42 41 1.03 Agreement 4th/o0 E2478-162 Filter Gross 20 21 0.97 Agreement Alpha Gross 136 114 1.19 Agreement 4th/00 Beta E2479-162 4t/00 Water H-3 9657 10082 0.96 Agreement E2480-162 Milk I-131LL 89 85 1.05 Agreement 1-131 86 85 1.01 Agreement Ce-141 362 356 1.02 Agreement Cr-51 521 503 1.04 Agreement Cs-134 84 85 0.99 Agreement Cs-137 204 199 1.02 Agreement Co-58 79 76 1.04 Agreement Mn-54 162 152 1.06 Agreement Fe-59 93 82 1.13 Agreement Zn-65 148 148 1.00 Agreement Co-60 185 184 1.00 Agreement E2592-162 ist/01 Water 1-131 88 90 0.98 Agreement 1-131LL 89 90 0.99 Agreement Ce-141 100 94 1.06 Agreement Cr-51 236 242 0.98 Agreement Cs-134 120 129 0.93 Agreement Cs-137 97 102 0.95 Agreement Co-58 48 48 1.00 Agreement Mn-54 103 101 1.02 Agreement Fe-59 88 84 1.05 Agreement Zn-65 187 186 1.01 Agreement ist/01 Co-60 144 147 0.98 Agreement E2593-162 Water Gross 40 39 1.03 Agreement Alpha Gross 300 268 1.12 Agreement ist/01 Beta E2598A Filter Gross 30 30 1.00 Agreement 162 Alpha Gross 229 211 1.18 Agreement is/01 Beta E2594-162 Water Ra-226 51 5O 1.02 Agreement Ra-228 63 63 1.00 Agreement
- pCi/Liter (Filters in pCi) 82
DESEL RESULTS IN THE ANALYTICS INC. CROSS CHECK PROGRAM Quarter 4, 2000 - Quarter 3, 2001 Sample Quarter Sample Nuclide Reported Known Ratio Evaluation Year Media Value DESL/ yValue
- 1. __________1 I_________Analytics ________
E2595 ir/01 Milk 1-131 78 77 1.01 Agreement 162 1-131LL 74 77 0.96 Agreement Ce-141 166 162 1.02 Agreement Cr-51 455 418 1.09 Agreement Cs-134 217 223 0.97 Agreement Cs-137 173 176 0.98 Agreement Co-58 86 82 1.05 Agreement Mn-54 185 175 1.06 Agreement Fe-59 151 146 1.03 Agreement Zn-65 328 322 1.02 Agreement Co-60 252 254 0.99 Agreement E2597 ISt/ 01 Water Am-241 5.6 6.0 0.93 Agreement 162 Pu-238 7.2 7.5 0.96 Agreement Pu-239 5.5 5.5 1.00 Agreement Np-237 9.6 7.9 1.22 Non-Agreement Cm-244 5.6 6.3 0.89 Agreement 2nd/01 Agreement E2670 Milk 1-131 63 69 0.91 162 I-131LL 66 69 0.96 Agreement Ce-141 165 163 1.01 Agreement Cr-51 228 224 1.02 Agreement Cs-134 131 134 0.98 Agreement Cs-137 128 121 1.06 Agreement Co-58 97 96 1.01 Agreement Mn-54 154 150 1.03 Agreement Fe-59 91 88 1.03 Agreement Zn-65 180 182 0.99 Agreement Co-60 138 135 1.03 Agreement E2666 Filter Ce-141 91 96 0.95 Agreement 162 Cr-51 130 132 0.98 Agreement Cs-134 74 79 0.94 Agreement Cs-137 77 71 1.08 Agreement Co-58 57 57 1.00 Agreement Mn-54 99 88 1.13 Agreement Fe-59 58 51 1.14 Agreement Zn-65 118 107 1.10 Agreement Co-60 77 79 0.97 Agreement
- Units in pCi/Liter (filter in pCi) 83
DESEL RESULTS IN THE ANALYTICS INC. CROSS CHECK PROGRAM Quarter 4, 2000 - Quarter 3, 2001 Sample Quarter Sample Nuclide Reported Known Ratio Evaluation Year Media Value
- Value
- ESEL!
.Analytics E2669 2 "/01 Water H-3 7007 7494 0.94 Agreement 162 2n1/01 Agreement E2667 Filter Sr-89 89 84 1.06 162 Sr-90 75 64 1.17 Agreement 3r1/01 E2806 Water 1-131 63 60 1.05 Agreement 162 1-13ILL 62 60 1.04 Agreement Ce-141 96 88 1.09 Agreement Cr-51 275 265 1.04 Agreement Cs-134 113 116 0.97 Agreement Cs-137 234 232 1.01 Agreement Co-58 132 128 1.03 Agreement Mn-54 153 149 1.03 Agreement Fe-59 66 62 1.06 Agreement Zn-65 184 184 1.00 Agreement Co-60 195 193 1.01 Agreement 3 rd/01 E2805 Water Gross 84 78 1.08 Agreement 162 Alpha Gross 175 205 0.85 Agreement Beta E2808 Filter Gross 51 50 1.02 Agreement 162 Alpha Gross 136 133 1.02 Agreement Beta E2809 3 rd/01 Milk 1-131 90 91 0.99 Agreement 162 1-131LL 91 91 1.00 Agreement Ce-141 131 121 1.08 Agreement Cr-51 374 366 1.02 Agreement Cs-134 157 160 0.98 Agreement Cs-137 323 319 1.01 Agreement Co-58 182 177 1.03 Agreement Mn-54 211 205 1.03 Agreement Fe-59 87 86 1.01 Agreement Zn-65 261 254 1.03 Agreement Co-60 274 266 1.03 Agreement 3 rd/01 E2807 Water Sr-89 87 85 1.02 Agreement 162 Sr-90 61 59 1.03 Agreement E2810 Milk Sr-89 121 75 1.61 Non 162 Agreement Sr-90 49 50 0.98 Agreement *Units in pCi/Liter (filters in pCi)
If known value falls within 2 sigma range acceptance criteria is met Bias Acceptance Criteria +/- 15%, or as noted below: Precision Acceptance Criteria +/- 15%, or Gross alpha, Sr89/90 +/- 25% as noted below: TRU and Radium +/- 20% or, if known value falls Gross alpha, Sr89/90 +/-25% Within 2 sigma range acceptance criteria is met TRU and Radium +/- 20 % 84
TABLE 4.3
SUMMARY
OF BLIND DUPLICATE SAMPLES SUBMITTED TO January - December 2001 TYP OF SAPL NUBROFPIE 8 cow milk Ground Water 2 Surface Water 14 Irish Moss 2 Mussels 4 Food Product -Cranberries 1 TOTAL 31 85
TABLE 4.4 Summary of Blind Duplicate Results Acceptance Criteria January -December 2001
- Analysis Yankee Maine Seabrook Entergy Total Type Atomic Yankee Station Gamma** 0 / 225 1 / 125 1 / 200 2 / 225 4 / 775 Gross Beta 1 /5 - - - 1/ 5 1-131 LL - - - 0 / 8 0 / 8 Sr-89 - - - 0 /4 0/ 4 Sr-90 - - - 0 /4 0/ 4 H-3 015 - - - 0 5 Total 1 / 235 1/ 125 1/ 200 2 / 241 1 5 / 801
- The number of measurements that fail to meet the acceptance criteria is shown before the slash.
- The gamma numbers represent the total radionuclide measurements in a gamma isotopic analysis.
86
5.0 Land Use Census Technical Requirements Program (TRP 5.2C.9.2.1) requires that a Land Use Census be conducted annually to identify the location of the nearest residence, milk animal and nearest garden of greater than 50 square meters producing broad leaf vegetation in each of the 16 meteorological sectors within five miles of the plant. The 2001 census was completed in accordance with the requirements of the ODCM. The census is used to identify the location of the nearest milk animal, the nearest residence, and the nearest garden of 50 square meters within five miles of plant. In 2001, A global positioning system was used. The nearest resident, garden and milk animal locations identified in the 2001 Land Use Census and their distances are shown in Table 5.1. The results of this census showed that the sampling locations currently being used have the highest calculated dose commitment. 87
Table 5.1 Land Use Census Results Sector (kmn) (kin) (kin) N 4.3 4.5 NNE 3.0 3.1 NE 2.9 3.0 ENE 2.3 E 2.6 ESE 2.7 SE 2.4 SSE 3.4 S 1.2 3.4 SSW 1.1 1.4 SW 1.1 1.7 5.2 WSW 1.6 2.3 W 1.3 1.4 WNW 1.1 1.4 6.1 NW 1.3 1.3 6.9 NNW 1.0 1.2 5.3 88
6.0 Reference 6.1 Seabrook Station Technical Requirements Manual 6.2 Seabrook Station Off-Site Dose Calculation Manual 89
ATTACHMENT I Sample Analysis Data
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) IRISH MOSS AL 05 60119 05/21/01 Th-232 1. 41E+01 1. 61E+01 5. 49E+01 AL 05 60119 05/2 1/01 Ag-IIOM -1. 92E+00 5. 41E+00 1. 99E+01 AL 05 60119 05/2 1/01 Ba-140 3. 09E+00 1. 05E+01 4. 08E+01 AL 05 60119 05/21/01 Be-7 3. 20E+00 3. 24E+01 1. 15E+02 AL 05 60119 05/21/01 Ce-141 1. 09E+00 4. 95E+00 1.70E+01 AL 05 60119 05/21/01 Ce-144 -2. 11E+01 1. 39E+01 5. 01E+01 AL 05 60119 05/21/01 Co-57 -0.70E+00 1. 65E+00 5. 78E+00 AL 05 60119 05/21/01 Co-58 -3. 08E+00 3. 97E+00 1. 51E+01 AL 05 60119 05/21/01 Co-60 -3. 99E+00 4.77E+00 1. 83E+01 AL 05 60119 05/21/01 Cr-51 -1. 57E+01 3. 38E+01 1.22E+02 AL 05 60119 05/21/01 Cs-134 -1. 72E+00 3. 91E+00 1. 45E+01 AL 05 60119 05/21/01 Cs-137 0. OOE+00 3. 69E+00 1. 32E+01 AL 05 60119 05/21/01 Fe-59 4. 09E+01 1. 84E+01 5. 80E+01 AL 05 60119 05/21/01 1-131 -2.59E+01 2. 16E+01 8. 02E+01 AL 05 60119 05/21/01 K-40 7. 52E+03 2. 28E+02 1.69E+02 AL 05 60119 05/21/01 Mn-54 1. 74E+00 3. 89E+00 1. 36E+01 AL 05 60119 05/21/01 Ru-103 7.42E+00 3. 93E+00 1. 27E+01 AL 05 60119 05/21/01 Ru-106 2.21E+01 3. 36E+01 1. 16E+02 AL 05 60119 05/21/01 Sb-124 1. 99E+01 8. 56E+00 2.38E+01 AL 05 60119 05/21/01 Se-75 -6. 87E+00 3. 97E+00 1. 45E+01 AL 05 60119 05/21/01 Zn-65 0. OOE+00 1. 17E+01 4.17E+01 AL 05 60119 05/21/01 Zr-95 -4.21E+00 7. 10E+00 2. 66E+01 AL 05 63064 11/19/01 Th-232 -4 .53E+01 2. 92E+01 1. 27E+02 AL 05 63064 11/19/01 Ag-11GM 1.23E+01 1. 18E+01 4. 09E+01 AL 05 63064 11/19/01 Ba-140 -6. 35E+01 3. 36E+01 1.79E+02 AL 05 63064 11/19/01 Be-7 2.8 9E+01 8. 67E+01 3. 17E+02 AL 05 63064 11/19/01 Ce-141 1. 15E+00 1. 71E+01 6. 10E+01 AL 05 63064 11/19/01 Ce-144 -1. 47E+00 3.70E+01 1. 34E+02 AL 05 63064 11/19/01 Co-57 4 .82E+00 4. 94E+00 1. 69E+01 AL 05 63064 11/19/01 Co-58 4. 16E+00 1. 14E+01 4.18E+01 AL 05 63064 11/19/01 Co-60 -1. 32E+01 8. 75E+00 4. 02E+01 AL 05 63064 11/19/01 Cr-51 -6. 54E+01 1. 22E+02 4. 61E+02 AL 05 63064 11/19/01 Cs-134 -9. 06E+00 8. 30E+00 3.53E+01 AL 05 63064 11/19/01 Cs-137 5. 10E+00 8. 19E+00 2. 95E+01 AL 05 63064 11/19/01 Fe-59 -3. 79E+01 3. 63E+01 1. 55E+02 AL 05 63064 11/19/01 1-131 0. OOE+00 8. 49E+01 3. 19E+02 AL 05 63064 11/19/01 K-40 6. 81E+03 4. 15E+02 4.93E+02 AL 05 63064 11/19/01 Mn-54 -6. 69E+00 8. 20E+00 3. 37E+01 AL 05 63064 11/19/01 Ru-103 8. 07E+00 1. 11E+01 3. 93E+01 AL 05 63064 11/19/01 Ru-106 -1. 41E+02 7. 02E+01 3. 08E+02 AL 05 63064 11/19/01 Sb-124 -1. 59E+00 1. 67E+01 7. 76E+01 AL 05 63064 11/19/01 Se-75 1.29E+00 1.OOE+01 3. 62E+01 AL 05 63064 11/19/01 Zn-65 -5. 38E+01 2. 66E+01 1. 12E+02 AL 05 63064 11/19/01 Zr-95 -1. 92E+01 1.54E+01 6. 75E+01
- Concentration Greater than 3 Standard Deviations 2
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) IRISH MOSS AL 55 60121 05/21/01 Th-232 -3. 73E+00 1. 51E+01 5. 47E+01 AL 55 60121 05/21/01 Ag-IlOM -1. 05E+01 5. 51E+00 2. 19E+01 AL 55 60121 05/21/01 Ba-140 0. OOE+00 1. 26E+01 4 .86E+01 AL 55 60121 05/21/01 Be-7 2. 27E+01 3. 23E+01 1. 11E+02 AL 55 60121 05/21/01 Ce-141 -4. 99E+00 4. 90E+00 1.75E+01 AL 55 60121 05/21/01 Ce-144 -1. 89E+01 1. 41E+01 5. 07E+01 AL 55 60121 05/21/01 Co-57 -0. 61E+00 1. 60E+00 5. 61E+00 AL 55 60121 05/21/01 Co-58 -3. 53E+00 4 13E+00 1. 57E+01 AL 55 60121 05/21/01 Co-60 4.51E+00 4. 72E+00 1. 62E+01 AL 55 60121 05/21/01 Cr-51 -2.22E+01 3. 82E+01 1. 37E+02 AL 55 60121 05/21/01 Cs-134 2. 64E+00 3. 94E+00 1. 37E+01 AL 55 60121 05/21/01 Cs-137 -1. 52E+00 3. 31E+00 1. 23E+01 AL 55 60121 05/21/01 Fe-59 1. 36E+01 1. 66E+01 5. 76E+01 AL 55 60121 05/21/01 1-131 -3. 06E+01 2. 03E+01 7. 64E+01 AL 55 60121 05/21/01 K-40 5. 84E+03 2 . 07E+02 1.98E+02 AL 55 60121 05/21/01 Mn-54 1. 34E+00 4.16E+00 1. 46E+01 AL 55 60121 05/21/01 Ru-103 -0. 88E+00 3. 65E+00 1. 34E+01 AL 55 60121 05/21/01 Ru-106 -5. 55E+01 3. 03E+01 1. 19E+02 AL 55 60121 05/21/01 Sb-124 4. 50E+00 7. 12E+00 2. 70E+01 AL 55 60121 05/21/01 Se-75 3.4 4E+00 3. 85E+00 1.30E+01 AL 55 60121 05/21/01 Zn-65 -1. 06E+01 1. 03E+01 3. 91E+01 AL 55 60121 05/21/01 Zr-95 -7. 34E+00 7. 50E+00 2.85E+01 AL 55 63065 11/19/01 Th-232 3. 10E+01 1.26E+01 4. 02E+01 AL 55 63065 11/19/01 Ag-iIGM -7. 55E+00 4. 65E+00 1. 73E+01 AL 55 63065 11/19/01 Ba-140 1. 33E+01 1.33E+01 4. 56E+01 AL 55 63065 11/19/01 Be-7 4.28E+01 3.22E+01 1. 07E+02 AL 55 63065 11/19/01 Ce-141 -4.74E+00 6. 43E+00 2.19E+01 AL 55 63065 11/19/01 Ce-144 4. 69E+00 1. 15E+01 3. 89E+01 AL 55 63065 11/19/01 Co-57 1.36E+00 1.41E+00 4. 70E+00 AL 55 63065 11/19/01 Co-58 -7. 89E+00 3.28E+00 1.28E+01 AL 55 63065 11/19/01 Co-60 4. 94E+00 3. 59E+00 1.20E+01 AL 55 63065 11/19/01 Cr-51 -2.59E+01 3.53E+01 1. 24E+02 AL 55 63065 11/19/01 Cs-134 2. 03E+00 3. 29E+00 1. 13E+01 AL 55 63065 11/19/01 Cs-137 -5. 18E+00 2. 97E+00 1. 10E+01 AL 55 63065 11/19/01 Fe-59 1. 97E+00 1.36E+01 4.79E+01 AL 55 63065 11/19/01 1-131 -3. 10E+00 2. 60E+01 9. 01E+01 AL 55 63065 11/19/01 K-40 3. 85E+03 1. 30E+02 1.59E+02 AL 55 63065 11/19/01 Mn-54 2 . 55E+00 3. 23E+00 1. 10E+01 AL 55 63065 11/19/01 Ru-103 -4.86E+00 3. 50E+00 1.28E+01 AL 55 63065 11/19/01 Ru-106 1. 59E+01 2. 77E+01 9. 44E+01 AL 55 63065 11/19/01 Sb-124 1.34E+01 8. 88E+00 2. 93E+01 AL 55 63065 11/19/01 Se-75 1. 44E+00 3. 18E+00 1. 08E+01 AL 55 63065 11/19/01 Zn-65 -1. 89E+01 9. 13E+00 3. 41E+01 AL 55 63065 11/19/01 Zr-95 -3. 28E+00 6. 26E+00 2. 25E+01
- Concentration Greater than 3 Standard Deviations 3
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 57907 01/03/01 GR-B 7. 76E-03 1. 42E-03 4 . 1OE-03 AP 02 57908 01/03/01 GR-B 6.4 6E-03 1. 47E-03 4 .33E-03 AP 03 57909 01/03/01 GR-B 8. 87E-03 1. 58E-03 4 .45E-03 AP 04 57910 01/03/01 GR-B 8.88E-03 1 49E-03 4. 21E-03 AP 05 57911 01/03/01 GR-B 9.23E-03 1. 45E-03 4 01E-03 AP 06 57912 01/03/01 GR-B 8.79E-03 1. 51E-03 4 .25E-03 AP 07 57913 01/03/01 GR-B 6.30E-03 1 .40E-03 4 14E-03 AP 08 57914 01/03/01 GR-B 8. 10E-03 1. 50E-03 4. 20E-03 AP 01 57971 01/10/01 GR-B 2. 65E-02 1. 83E-03 4. 51E-03 AP 02 57972 01/10/01 GR-B 2. 84E-02 1. 96E-03 4. 82E-03 AP 03 57973 01/10/01 GR-B 3. 01E-02 1. 92E-03 4. 62E-03 AP 04 57974 01/10/01 GR-B 3. 09E-02 1.86E-03 4 38E-03 AP 05 57975 01/10/01 GR-B 3 90E-02 2. 01E-03 4. 57E-03 AP 06 57976 01/10/01 GR-B 3. 18E-02 1. 96E-03 4. 64E-03 AP 07 57977 01/10/01 GR-B 2. 38E-02 1.86E-03 4. 59E-03 AP 08 57978 01/10/01 GR-B 3. 61E-02 1. 99E-03 4 .58E-03 AP 01 58112 01/17/01 GR-B 1 .78E-02 1.76E-03 4. 50E-03 AP 02 58113 01/17/01 GR-B 2. 13E-02 1. 90E-03 4. 73E-03 AP 03 58114 01/17/01 GR-B 2. 17E-02 1. 88E-03 4. 65E-03 AP 04 58115 01/17/01 GR-B 2. 15E-02 1. 83E-03 4. 50E-03 AP 05 58116 01/17/01 GR-B 2. 61E-02 1.85E-03 4 .28E-03 AP 06 58117 01/17/01 GR-B 2. 03E-02 1. 81E-03 4 .48E-03 AP 07 58118 01/16/01 GR-B 2. 07E-02 2. 03E-03 5. 21E-03 AP 08 58119 01/17/01 GR-B 2. 08E-02 1.8 9E-03 4. 60E-03 AP 01 58186 01/24 /01 GR-B 2. 18E-02 1. 75E-03 4 .13E-03 AP 02 58187 01/24 /01 GR-B 2. 63E-02 1. 90E-03 4.34E-03 AP 03 58188 01/24 /01 GR-B 2. 31E-02 1. 81E-03 4.25E-03 AP 04 58189 01/24 /01 GR-B 2. 45E-02 1. 81E-03 4.04E-03 AP 05 58190 01/24 /01 GR-B 3. 14E-02 1.90E-03 3.99E-03 AP 06 58191 01/24 /01 GR-B 2. 15E-02 1. 78E-03 4.21E-03 AP 07 58192 01/24 /01 GR-B 1. 69E-02 1. 53E-03 3. 71E-03 AP 08 58193 01/24 /01 GR-B 2 .27E-02 1. 82E-03 4.21E-03 AP 01 58334 01/31 /01 GR-B 2 .26E-02 1. 77E-03 4. 12E-03 AP 02 58335 01/31 /01 GR-B 2. OOE-02 1. 87E-03 4 .53E-03 AP 03 58336 01/31 /01 GR-B 2. 53E-02 1. 96E-03 4 .40E-03 AP 04 58337 01/31 /01 GR-B 2. 56E-02 1. 85E-03 4. 22E-03 AP 05 58338 01/31 /01 GR-B 3. 1OE-02 1. 95E-03 4 . 10E-03 AP 06 58339 01/31 /01 GR-B 2. 65E-02 1. 86E-03 4. 20E-03 AP 07 58340 01/31 /01 GR-B 2 45E-02 1. 85E-03 4 17E-03 AP 08 58341 01/31 /01 GR-B 2. 17E-02 1. 81E-03 4. 21E-03
- Concentration Greater than 3 Standard Deviations 4
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 58480 02/07/01 GR-B 1. 90E-02 1. 76E-03 4. 50E-03 AP 02 58481 02/07/01 GR-B 2. 02E-02 2 00E-03 5. 15E-03 AP 03 58482 02/07/01 GR-B 2. 12E-02 1. 82E-03 4 .72E-03 AP 04 58483 02/07/01 GR-B 2. 26E-02 1. 84E-03 4 .65E-03 AP 05 58484 02/07/01 GR-B 2 .48E-02 1.76E-03 4. 39E-03 AP 06 58485 02/07/01 GR-B 2. 01E-02 1.76E-03 4. 58E-03 AP 07 58486 02/07/01 GR-B 2. 01E-02 1 77E-03 4 54E-03 AP 08 58487 02/07/01 GR-B 1. 94E-02 1. 76E-03 4. 60E-03 AP 01 58585 02/14 /01 GR-B 2. 01E-02 1. 79E-03 4. 29E-03 AP 02 58586 02/14 /01 GR-B 2 48E-02 1. 88E-03 4 41E-03 AP 03 58587 02/14 /01 GR-B 1. 92E-02 1. 85E-03 4 .46E-03 AP 04 58588 02/14 /01 GR-B 2 .21E-02 1 . 77E-03 4 19E-03 AP 05 58589 02/14 /01 GR-B 2 64E-02 1. 87E-03 4 .25E-03 AP 06 58590 02/14 /01 GR-B 1. 83E-02 1. 75E-03 4. 37E-03 AP 07 58591 02/14 /01 GR-B 1. 99E-02 1. 85E-03 4 43E-03 AP 08 58592 02/14 /01 GR-B 2. 03E-02 1. 78E-03 4 38E-03 AP 01 58665 02/21 /01 GR-B 3. 15E-02 1. 88E-03 4. 51E-03 AP 02 58666 02/21 /01 GR-B 2. 84E-02 1. 91E-03 4. 66E-03 AP 03 58667 02/21 /01 GR-B 2. 73E-02 1. 96E-03 4 .84E-03 AP 04 58668 02/21 /01 GR-B 3. 32E-02 1. 98E-03 4. 66E-03 AP 05 58669 02/21 /01 GR-B 3. 64E-02 1. 98E-03 4. 54E-03 AP 06 58670 02/21 /01 GR-B 3. 07E-02 1. 94E-03 4. 60E-03 AP 07 58671 02/21 /01 GR-B 3. 08E-02 1. 87E-03 4 45E-03 AP 08 58672 02/21 /01 GR-B 2.86E-02 1. 91E-03 4. 61E-03 AP 01 58764 02/28/01 GR-B 1.57E-02 1.66E-03 4.54E-03
- AP 02 58765 02/28/01 GR-B 1.74E-02 1.71E-03 4.64E-03
- AP 03 58766 02/28/01 GR-B 1. 61E-02 1.75E-03 4. 74E-03 AP 04 58767 02/28/01 GR-B 1.89E-02 1.72E-03 4. 55E-03 AP 05 58768 02/28/01 GR-B 1.88E-02 1. 72E-03 4. 57E-03 AP 06 58769 02/28/01 GR-B 1. 68E-02 1. 68E-03 4. 56E-03 AP 07 58770 02/28/01 GR-B 1. 82E-02 1. 77E-03 4. 63E-03 AP 08 58771 02/28/01 GR-B 1. 55E-02 1. 71E-03 4. 62E-03 AP 01 58877 03/07/01 GR-B 1.71E-02 1. 68E-03 4 .53E-03
- AP 02 58878 03/07/01 GR-B 1.79E-02 1. 75E-03 4. 68E-03
- AP 03 58879 03/07/01 GR-B 2. 27E-02 1. 82E-03 4. 74E-03 AP 04 58880 03/07/01 GR-B 1. 84E-02 1.76E-03 4. 52E-03
- AP 05 58881 03/07/01 GR-B 2 . 27E-02 1. 76E-03 4. 54E-03 AP 06 58882 03/07/01 GR-B 1.74E-02 1. 73E-03 4. 69E-03 AP 07 58883 03/07/01 GR-B 1. 80E-02 1. 73E-03 4. 53E-03 AP 08 58884 03/07/01 GR-B 1. 99E-02 1. 72E-03 4. 55E-03
- Concentration Greater than 3 Standard Deviations 5
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 58987 03/14/01 GR-B 1. 01E-02 1. 57E-03 4 . 4 6E-03 AP 02 58988 03/14/01 GR-B 1. 05E-02 1. 64E-03 4. 68E-03 AP 03 58989 03/14/01 GR-B 1. 33E-02 1.73E-03 4. 88E-03 AP 04 58990 03/14/01 GR-B 1. 20E-02 1. 63E-03 4. 65E-03 AP 05 58991 03/14/01 GR-B 1. 4 9E-02 1. 67E-03 4. 58E-03 AP 06 58992 03/14/01 GR-B 1. 45E-02 1.71E-03 4 .60E-03 AP 07 58993 03/14/01 GR-B 1.21E-02 1. 64E-03 4. 56E-03 AP 08 58994 03/14/01 GR-B 1. 27E-02 1. 62E-03 4. 54E-03 AP 01 59087 03/20/01 GR-B 1. 4 6E-02 1. 58E-03 4. 18E-03 AP 02 59088 03/20/01 GR-B 1. 64E-02 1. 69E-03 4 41E-03 AP 03 59089 03/21/01 GR-B 1. 36E-02 1. 45E-03 3. 80E-03 AP 04 59090 03/21/01 GR-B 1. 39E-02 1. 45E-03 3. 82E-03 AP 05 59091 03/21/01 GR-B 1. 94E-02 1. 58E-03 3. 77E-03 AP 06 59092 03/21/01 GR-B 1. 52E-02 1. 44E-03 3. 73E-03 AP 07 59093 03/21/01 GR-B 1. 1OE-02 1. 35E-03 3. 67E-03 AP 08 59094 03/20/01 GR-B 1. 58E-02 1. 47E-03 3. 77E-03 AP 01 59162 03/28/01 GR-B 6. 56E-03 1. 31E-03 3. 80E-03 AP 02 59163 03/28/01 GR-B 1. 01E-02 1. 37E-03 3.69E-03 AP 03 59164 03/28/01 GR-B 1. 13E-02 1. 55E-03 4. 34E-03 AP 04 59165 03/28/01 GR-B 1. 14E-02 1. 64E-03 4. 57E-03 AP 05 59166 03/28/01 GR-B 1. 55E-02 2. 16E-03 6. 06E-03 AP 06 59167 03/28/01 GR-B 1. OOE-02 1. 52E-03 4. 35E-03 AP 07 59168 03/28/01 GR-B 1. 17E-02 1. 55E-03 4.31E-03 AP 08 59169 03/28/01 GR-B 9. 93E-03 1. 53E-03 4. 36E-03 AP 01 59279 04/04/01 GR-B 1. 37E-02 1. 33E-03 3. 35E-03 AP 02 59280 04/04/01 GR-B 1. 18E-02 1. 25E-03 3. 25E-03 AP 03 59281 04/04/01 GR-B 1. 05E-02 1.29E-03 3. 38E-03 AP 04 59282 04/04/01 GR-B 1. 20E-02 1.40E-03 3. 55E-03 AP 05 59283 04/04/01 GR-B 1. 42E-02 1.4 8E-03 3. 71E-03 AP 06 59284 04/04/01 GR-B 9. 45E-03 1. 23E-03 3. 39E-03 AP 07 59285 04/04/01 GR-B 9. 4 6E-03 1. 25E-03 3. 4 1E-03 AP 08 59286 04/04/01 GR-B 9. 60E-03 1. 26E-03 3. 4 1E-03 AP 01 59433 04/11/01 GR-B 1. 16E-02 1. 63E-03 4. 23E-03 AP 02 59434 04/11/01 GR-B 1. 30E-02 1. 56E-03 4. 12E-03 AP 03 59435 04/11/01 GR-B 1. 60E-02 1. 66E-03 4. 21E-03 AP 04 59436 04/11/01 GR-B 1. 57E-02 1. 71E-03 4. 38E-03 AP 05 59437 04/11/01 GR-B 1. 82E-02 1. 81E-03 4 .49E-03 AP 06 59438 04/11/01 GR-B 1. 60E-02 1. 72E-03 4 .37E-03 AP 07 59439 04/11/01 GR-B 1. 4 6E-02 1. 67E-03 4. 26E-03 AP 08 59440 04/11/01 GR-B 1. 58E-02 1. 68E-03 4 .32E-03
- Concentration Greater than 3 Standard Deviations 6
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 59519 04/17/01 GR-B 1 . 68E-02 1.79E-03 4. 67E-03 AP 02 59520 04/17/01 GR-B 1.75E-02 1.75E-03 4. 60E-03 AP 03 59521 04/18/01 GR-B 1.75E-02 1. 68E-03 4.24E-03 AP 04 59522 04/18/01 GR-B 1.47E-02 1. 65E-03 4.44E-03 AP 05 59523 04/18/01 GR-B 2. 15E-02 1. 75E-03 4.44E-03 AP 06 59524 04/17/01 GR-B 1.70E-02 1.79E-03 4.73E-03 AP 07 59525 04/17/01 GR-B 1.20E-02 1.76E-03 4.73E-03 AP 08 59526 04/17/01 GR-B 1. 43E-02 1. 77E-03 4.78E-03 AP 01 59616 04/25/01 GR-B 1. 99E-02 1. 55E-03 3.89E-03 AP 02 59617 04/25/01 GR-B 2. 09E-02 1. 52E-03 3. 81E-03 AP 03 59618 04/25/01 GR-B 2.21E-02 1. 72E-03 4.44E-03 AP 04 59619 04/25/01 GR-B 2.26E-02 1.84E-03 4. 64E-03 AP 05 59620 04/25/01 GR-B 2. 87E-02 1. 91E-03 4. 63E-03 AP 06 59621 04/25/01 GR-B 2. 05E-02 1.59E-03 3. 99E-03 AP 07 59622 04/25/01 GR-B 2. 09E-02 1.58E-03 3. 91E-03 AP 08 59623 04/25/01 GR-B 2.18E-02 1. 62E-03 3. 96E-03 AP 01 59792 05/02/01 GR-B 1. 69E-02 1. 64E-03 4. 07E-03 AP 02 59793 05/02/01 GR-B 2. 82E-02 1.85E-03 3. 97E-03 AP 03 59794 05/02/01 GR-B 2. 57E-02 1. 85E-03 4.16E-03 AP 04 59795 05/02/01 GR-B 2. 20E-02 1.86E-03 4.38E-03 AP 05 59796 05/02/01 GR-B 3. 30E-02 2. 05E-03 4.34E-03 AP 06 59797 05/02/01 GR-B 2.84E-02 1. 90E-03 4. 11E-03 AP 07 59798 05/02/01 GR-B 1. 73E-02 1. 68E-03 4 .07E-03 AP 08 59799 05/02/01 GR-B 1. 96E-02 1. 76E-03 4 .17E-03 AP 01 59871 05/09/01 GR-B 1. 98E-02 1. 65E-03 4.14E-03 AP 02 59872 05/09/01 GR-B 2. 66E-02 1. 72E-03 4. 11E-03 AP 03 59873 05/09/01 GR-B 2. 57E-02 1. 83E-03 4.42E-03 AP 04 59874 05/09/01 GR-B 2 . 56E-02 1. 91E-03 4.70E-03 AP 05 59875 05/09/01 GR-B 2. 95E-02 1. 88E-03 4 .46E-03 AP 06 59876 05/09/01 GR-B 2. 33E-02 1. 72E-03 4.29E-03 AP 07 59877 05/09/01 GR-B 2. 16E-02 1.71E-03 4.33E-03 AP 08 59878 05/09/01 GR-B 2. 02E-02 1.70E-03 4.23E-03 AP 01 59952 05/16/01 GR-B 2. 01E-02 1.70E-03 4.37E-03 AP 02 59953 05/16/01 GR-B 2. 1OE-02 1. 70E-03 4.36E-03 AP 03 59954 05/16/01 GR-B 2. 07E-02 1.77E-03 4.55E-03 AP 04 59955 05/16/01 GR-B 1.84E-02 1.7 6E-03 4. 61E-03 AP 05 59956 05/16/01 GR-B 2. 16E-02 1.83E-03 4.74E-03 AP 06 59957 05/16/01 GR-B 2. 07E-02 1.71E-03 4.38E-03 AP 07 59958 05/16/01 GR-B 1. 58E-02 1. 64E-03 4.32E-03 AP 08 59959 05/16/01 GR-B 1. 92E-02 1.74E-03 4.45E-03
- Concentration Greater than 3 Standard Deviations 7
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 60083 05/22/01 GR-B 6.52E-03 1.56E-03 4. 66E-03 AP 02 60084 05/23/01 GR-B 1. 14E-02 1. 43E-03 3. 75E-03 AP 03 60085 05/23/01 GR-B 1. 08E-02 1. 50E-03 4. 06E-03 AP 04 60086 05/23/01 GR-B 1.27E-02 1. 62E-03 4.20E-03 AP 05 60087 05/23/01 GR-B 1. 60E-02 1. 60E-03 4 . OOE-03 AP 06 60088 05/23/01 GR-B 1. 12E-02 1. 51E-03 4. 06E-03 AP 07 60089 05/23/01 GR-B 1 .lIE-02 1.50E-03 4. 06E-03 AP 08 60090 05/23/01 GR-B 1.29E-02 1.56E-03 4. 03E-03 AP 01 60232 05/30/01 GR-B 8. 38E-03 1. 35E-03 3. 71E-03 AP 02 60233 05/30/01 GR-B 8. 97E-03 1.52E-03 4.08E-03 AP 03 60234 05/30/01 GR-B 9. 32E-03 1. 59E-03 4.38E-03 AP 04 60235 05/30/01 GR-B 1. 12E-02 1. 65E-03 4 .4 9E-03 AP 05 60236 05/30/01 GR-B 1. 45E-02 1. 69E-03 4. 32E-03 AP 06 60237 05/30/01 GR-B 1. 14E-02 1. 61E-03 4. 36E-03 AP 07 60238 05 /30/01 GR-B 9. 11E-03 1. 51E-03 4.19E-03 AP 08 60239 05/30/01 GR-B 8. 28E-03 1. 59E-03 4.38E-03 AP 01 60409 06/06/01 GR-B 4. 93E-03 1. 43E-03 4. 20E-03 AP 02 60410 06/06/01 GR-B 7 45E-03 1. 28E-03 3. 61E-03 AP 03 60411 06/06/01 GR-B 5. 49E-03 1. 47E-03 4 40E-03 AP 04 60412 06/06/01 GR-B 7 .42E-03 1. 55E-03 4 .48E-03 AP 05 60413 06/06/01 GR-B 6. 34E-03 1 49E-03 4 .34E-03 AP 06 60414 06/06/01 GR-B 6. 19E-03 1. 47E-03 4 .29E-03 AP 07 60415 06/06/01 GR-B 8. 76E-03 1. 51E-03 4 .28E-03 AP 08 60416 06/06/01 GR-B 6. 94E-03 1 49E-03 4 .27E-03 AP 01 60500 06/13/01 GR-B 1. 88E-02 1. 48E-03 3. 59E-03 AP 02 60501 06/13/01 GR-B 1. 77E-02 1. 44E-03 3. 4 9E-03 AP 03 60502 06/13/01 GR-B 1. 63E-02 1. 51E-03 3. 85E-03 AP 04 60503 06/13/01 GR-B 1. 95E-02 1. 62E-03 3. 96E-03 AP 05 60504 06/13/01 GR-B 2. 41E-02 1. 62E-03 3. 74E-03 AP 06 60505 06/13/01 GR-B 1. 48E-02 1. 43E-03 3. 63E-03 AP 07 60506 06/13/01 GR-B 1 11E-02 1. 33E-03 3. 59E-03 AP 08 60507 06/13/01 GR-B 1. 52E-02 1. 46E-03 3. 67E-03 AP 01 60565 06/20/01 GR-B 1. 83E-02 1. 71E-03 4 .49E-03 AP 02 60566 06/20/01 GR-B 2. 45E-02 1. 78E-03 4. 36E-03 AP 03 60567 06/20/01 GR-B 2. 42E-02 1. 92E-03 4. 89E-03 AP 04 60568 06/20/01 GR-B 2. 41E-02 1. 98E-03 5. 00E-03 AP 05 60569 06/20/01 GR-B 3. OOE-02 1. 97E-03 4. 82E-03 AP 06 60570 06/20/01 GR-B 2 .29E-02 1. 84E-03 4. 67E-03 AP 07 60571 06/20/01 GR-B 1.76E-02 1.81E-03 4.78E-03
- AP 08 60572 06/20/01 GR-B 2.13E-02 1.77E-03 4.56E-03 *
- Concentration Greater than 3 Standard Deviations 8
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 60744 06/27/01 GR-B 1. 50E-02 1 46E-03 3. 56E-03 AP 02 60745 06/27/01 GR-B 1. 87E-02 1 47E-03 3. 45E-03 AP 03 60746 06/27/01 GR-B 1. 73E-02 1. 55E-03 3. 81E-03 AP 04 60747 06/27/01 GR-B 1. 68E-02 1. 58E-03 3. 89E-03 AP 05 60748 06/27/01 GR-B 1. 94E-02 1. 57E-03 3. 76E-03 AP 06 60749 06/27/01 GR-B 1. 83E-02 1. 50E-03 3.55E-03 AP 07 60750 06/27/01 GR-B 1.21E-02 1. 38E-03 3. 59E-03 AP 08 60751 06/27/01 GR-B 1. 08E-02 1. 41E-03 3. 62E-03 AP 01 60816 07/03/01 GR-B 1. 83E-02 1. 96E-03 5. 24E-03 AP 02 60817 07/03/01 GR-B 2. 31E-02 1. 99E-03 5. 07E-03 AP 03 60818 07/03/01 GR-B 1. 85E-02 2. 05E-03 5. 51E-03 AP 04 60819 07/03/01 GR-B 1. 66E-02 2. 07E-03 5 .74E-03 AP 05 60820 07/03/01 GR-B 3. 07E-02 2. 16E-03 5.24E-03 AP 06 60821 07/03/01 GR-B 2. 01E-02 2. 03E-03 5 .27E-03 AP 07 60822 07/03/01 GR-B 1. 73E-02 1. 90E-03 5. 11E-03 AP 08 60823 07/03/01 GR-B 1. 67E-02 2. OOE-03 5. 39E-03 AP 01 60960 07/11/01 GR-B 8. 51E-03 1. 36E-03 3. 89E-03 AP 02 60961 07/11/01 GR-B 1. 13E-02 1. 39E-03 3.75E-03 AP 03 60962 07/11/01 GR-B 1. 15E-02 1. 58E-03 4.36E-03 AP 04 60963 07/11/01 GR-B 1. 45E-02 1. 66E-03 4.46E-03 AP 05 60964 07/11/01 GR-B 1. 66E-02 1.59E-03 4. 13E-03 AP 06 60965 07/11/01 GR-B 1.27E-02 1. 47E-03 4.04E-03 AP 07 60966 07/11/01 GR-B 1. 15E-02 1. 48E-03 4.08E-03 AP 08 60967 07/11/01 GR-B 1. 05E-02 1. 45E-03 3. 95E-03 AP 01 61051 07/18/01 GR-B 6.75E-03 1. 30E-03 3. 65E-03 AP 02 61052 07/18/01 GR-B 7. 37E-03 1. 24E-03 3. 53E-03 AP 03 61053 07/18/01 GR-B 6.39E-03 1.40E-03 4.04E-03 AP 04 61054 07/18/01 GR-B 7. 80E-03 1. 51E-03 4 .17E-03 AP 05 61055 07/18/01 GR-B 9.45E-03 1.37E-03 3.79E-03 AP 06 61056 07/18/01 GR-B 6. 07E-03 1. 27E-03 3. 71E-03 AP 07 61057 07/18/01 GR-B 7.4 9E-03 1.29E-03 3. 61E-03 AP 08 61058 07/18/01 GR-B 6. 68E-03 1. 31E-03 3. 71E-03 AP 01 61196 07/25/01 GR-B 1.75E-02 1. 46E-03 3. 56E-03 AP 02 61197 07/25/01 GR-B 2. 01E-02 1. 49E-03 3.4 6E-03 AP 03 61198 07/25/01 GR-B 2 08E-02 1. 63E-03 3.85E-03 AP 04 61199 07/25/01 GR-B 2. 06E-02 1. 67E-03 3. 92E-03 AP 05 61200 07/25/01 GR-B 2 . 94E-02 1. 73E-03 3.75E-03 AP 06 61201 07/25/01 GR-B 1. 87E-02 1. 53E-03 3. 65E-03 AP 07 61202 07/25/01 GR-B 1 48E-02 1. 47E-03 3.67E-03 AP 08 61203 07/25/01 GR-B 1. 90E-02 1. 52E-03 3. 60E-03
- Concentration Greater than 3 Standard Deviations 9
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 61318 08/01/01 GR-B 1 41E-02 1. 50E-03 3. 81E-03 AP 02 61319 08/01/01 GR-B 1. 59E-02 1. 50E-03 3. 67E-03 AP 03 61320 08/01/01 GR-B 1. 34E-02 1.56E-03 4 . 10E-03 AP 04 61321 08/01/01 GR-B 1. 60E-02 1.66E-03 4 .25E-03 AP 05 61322 08/01/01 GR-B 2. 14E-02 1. 64E-03 3. 90E-03 AP 06 61323 08/01/01 GR-B 1. 56E-02 1. 50E-03 3. 85E-03 AP 07 61324 08/01/01 GR-B 1. 50E-02 1. 50E-03 3. 81E-03 AP 08 61325 08/01/01 GR-B 1. 38E-02 1. 50E-03 3. 90E-03 AP 01 61436 08/07/01 GR-B 2. 94E-02 1.74E-03 3. 85E-03 AP 02 61437 08/08/01 GR-B 3. 91E-02 1.86E-03 3.75E-03 AP 03 61438 08/08/01 GR-B 4.71E-02 1. 95E-03 3. 67E-03 AP 04 61439 08/08/01 GR-B 3.24E-02 1.73E-03 3. 58E-03 AP 05 61440 08/08/01 GR-B 3.88E-02 1.88E-03 3. 71E-03 AP 06 61441 08/08/01 GR-B 3. 06E-02 1. 73E-03 3. 62E-03 AP 07 61442 08/08/01 GR-B 2.4 1E-02 1. 63E-03 3 64E-03 AP 08 61443 08/08/01 GR-B 2. 64E-02 1. 63E-03 3 64E-03 AP 01 61492 08/15/01 GR-B 2. 29E-02 1. 57E-03 3. 55E-03 AP 02 61493 08/15/01 GR-B 2 .4 9E-02 1.55E-03 3. 50E-03 AP 03 61494 08/15/01 GR-B 2. 33E-02 1. 53E-03 3. 47E-03 AP 04 61495 08/15/01 GR-B 2. 38E-02 1. 52E-03 3 40E-03 AP 05 61496 08/15/01 GR-B 3. 28E-02 1.79E-03 3. 73E-03 AP 06 61497 08/15/01 GR-B 2.23E-02 1.56E-03 3. 58E-03 AP 07 61498 08/15/01 GR-B 2. 29E-02 1. 60E-03 3.59E-03 AP 08 61499 08/15/01 GR-B 2. 19E-02 1.57E-03 3. 60E-03 AP 01 61564 08/22/01 GR-B 1 .45E-02 1. 63E-03 4 .48E-03 AP 02 61565 08/22/01 GR-B 2. 53E-02 1.76E-03 4. 38E-03 AP 03 61566 08/22/01 GR-B 2 44E-02 1.77E-03 4. 51E-03 AP 04 61567 08/22/01 GR-B 2. 19E-02 1.71E-03 4 .41E-03 AP 05 61568 08/22/01 GR-B 2.87E-02 1.88E-03 4 68E-03 AP 06 61569 08/22/01 GR-B 2. 22E-02 1.79E-03 4. 64E-03 AP 07 61570 08/22/01 GR-B 1. 68E-02 1. 69E-03 4. 54E-03 AP 08 61571 08/22/01 GR-B 1. 72E-02 1. 68E-03 4. 55E-03 AP 02 61662 08/29/01 GR-B 2. 17E-02 1. 75E-03 4. 29E-03 AP 03 61663 08/29/01 GR-B 2 42E-02 1. 85E-03 4.4 8E-03 AP 04 61664 08/29/01 GR-B 2. 29E-02 1. 83E-03 4 .45E-03 AP 05 61665 08/29/01 GR-B 1. 75E-02 1.81E-03 4. 58E-03 AP 06 61666 08/29/01 GR-B 1 .86E-02 1.81E-03 4 .48E-03 AP 07 61667 08/29/01 GR-B 2. 34E-02 1.79E-03 4.39E-03 AP 08 61668 08/29/01 GR-B 2. 07E-02 1.84E-03 4 .49E-03
- Concentration Greater than 3 Standard Deviations 10
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 61810 09/05/01 GR-B 1. 71E-02 1. 52E-03 3. 67E-03 AP 02 61811 09/05/01 GR-B 1. 64E-02 1. 39E-03 3. 31E-03 AP 03 61812 09/05/01 GR-B 1. 78E-02 1. 42E-03 3. 36E-03 AP 04 61813 09/05/01 GR-B 1. 72E-02 1. 41E-03 3. 24E-03 AP 05 61814 09/05/01 GR-B 2. 26E-02 1. 61E-03 3. 56E-03 AP 06 61815 09/05/01 GR-B 1. 54E-02 1. 47E-03 3. 4 9E-03 AP 07 61816 09/05/01 GR-B 1. 48E-02 1. 35E-03 3. 30E-03 AP 08 61817 09/05/01 GR-B 1. 58E-02 1. 45E-03 3. 4 9E-03 AP 01 61847 09/12/01 GR-B 1. 87E-02 1. 64E-03 3. 91E-03 AP 02 61848 09/12/01 GR-B 2. 45E-02 1. 85E-03 4. 24E-03 AP 03 61849 09/12/01 GR-B 2. 4 8E-02 1. 92E-03 4 48E-03 AP 04 61850 09/12/01 GR-B 2 .27E-02 1. 85E-03 4 42E-03 AP 05 61851 09/12/01 GR-B 2. 79E-02 2. 01E-03 4. 54E-03 AP 06 61852 09/12/01 GR-B 2 .23E-02 1. 84E-03 4 .46E-03 AP 07 61853 09/12/01 GR-B 1. 81E-02 1. 64E-03 4 05E-03 AP 08 61854 09/12/01 GR-B 1. 87E-02 1. 79E-03 4 .4 6E-03 AP 01 62001 09/19/01 GR-B 1. 64E-02 1. 68E-03 4. 36E-03 AP 02 62002 09/19/01 GR-B 2 . 37E-02 1. 75E-03 4. 29E-03 AP 03 62003 09/19/01 GR-B 2. 04E-02 1. 75E-03 4. 34E-03 AP 04 62004 09/19/01 GR-B 2. 36E-02 1. 70E-03 4. 23E-03 AP 05 62005 09/19/01 GR-B 2. 55E-02 1. 94E-03 4.56E-03 AP 06 62006 09/19/01 GR-B 2 .22E-02 1. 80E-03 4. 55E-03 AP 07 62007 09/19/01 GR-B 1. 69E-02 1. 65E-03 4. 27E-03 AP 08 62008 09/19/01 GR-B 1. 72E-02 1. 79E-03 4 .52E-03 AP 01 62174 09/26/01 GR-B 2. 23E-02 1. 57E-03 3. 58E-03 AP 02 62175 09/26/01 GR-B 2. 28E-02 1. 54E-03 3. 54E-03 AP 03 62176 09/26/01 GR-B 2. 07E-02 1. 55E-03 3. 67E-03 AP 04 62177 09/26/01 GR-B 2 . OOE-02 1. 54E-03 3. 55E-03 AP 05 62178 09/26/01 GR-B 2.76E-02 1 69E-03 3. 75E-03 AP 06 62179 09/26/01 GR-B 2. 03E-02 1. 62E-03 3. 71E-03 AP 07 62180 09/26/01 GR-B 1.74E-02 1. 45E-03 3. 49E-03 AP 08 62181 09/26/01 GR-B 1 .76E-02 1. 51E-03 3. 73E-03 AP 01 62190 10/03/01 GR-B 1. 61E-02 1. 41E-03 3. 43E-03 AP 02 62191 10/03/01 GR-B 1. 76E-02 1. 46E-03 3. 4 4E-03 AP 03 62192 10/03/01 GR-B 1 .35E-02 1. 43E-03 3. 67E-03 AP 04 62193 10/03/01 GR-B 1. 74E-02 1 46E-03 3. 58E-03 AP 05 62194 10/03/01 GR-B 2. 26E-02 1. 63E-03 3. 66E-03 AP 06 62195 10/03/01 GR-B 1. 60E-02 1. 51E-03 3. 70E-03 AP 07 62196 10/03/01 GR-B 1 .48E-02 1. 40E-03 3. 48E-03 AP 08 62197 10/03/01 GR-B 1 64E-02 1 . 52E-03 3. 69E-03
- Concentration Greater than 3 Standard Deviations 11
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 62369 10/10/01 GR-B 3. 36E-02 1. 79E-03 3. 60E-03 AP 02 62370 10/10/01 GR-B 3. 13E-02 1. 79E-03 3. 69E-03 AP 03 62371 10/10/01 GR-B 3. 19E-02 1. 74E-03 3. 56E-03 AP 04 62372 10/10/01 GR-B 3. 33E-02 1. 71E-03 3. 46E-03 AP 05 62373 10 /10/01 GR-B 4. 29E-02 2. 03E-03 3. 83E-03 AP 06 62374 10 /10/01 GR-B 3. 30E-02 1. 79E-03 3. 69E-03 AP 07 62375 10/10/01 GR-B 2. 93E-02 1. 71E-03 3. 62E-03 AP 08 62376 10/10/01 GR-B 2. 90E-02 1. 77E-03 3. 72E-03 AP 01 62475 10/17/01 GR-B 1.71E-02 1. 60E-03 3. 92E-03 AP 02 62476 10/17/01 GR-B 1. 67E-02 1. 65E-03 4. 12E-03 AP 03 62477 10/17/01 GR-B 1. 83E-02 1. 70E-03 4. 22E-03 AP 04 62478 10/17/01 GR-B 1. 50E-02 1. 63E-03 4.02E-03 AP 05 62479 10/17/01 GR-B 2. 33E-02 1.7 6E-03 4. 11E-03 AP 06 62480 10/17/01 GR-B 1. 47E-02 1. 64E-03 4.19E-03 AP 07 62481 10/17/01 GR-B 1. 63E-02 1.56E-03 3. 85E-03 AP 08 62482 10/17/01 GR-B 1. 61E-02 1. 63E-03 4 .13E-03 AP 01 62560 10/23/01 GR-B 2.52E-02 1.73E-03 3. 91E-03 AP 02 62561 10/23/01 GR-B 2.35E-02 1.76E-03 4.07E-03 AP 03 62562 10/23 /0 1 GR-B 2.4 9E-02 1.58E-03 3.47E-03 AP 04 62563 10/23/01 GR-B 2. 13E-02 1.45E-03 3.28E-03 AP 05 62564 10/23/01 GR-B 3.40E-02 1.76E-03 3. 60E-03 AP 06 62565 10/23/01 GR-B 2. 67E-02 1.84E-03 4.12E-03 AP 07 62566 10/23/01 GR-B 2. 28E-02 1.49E-03 3.29E-03 AP 08 62567 10/23/01 GR-B 2.43E-02 1.81E-03 4.18E-03 AP 01 62693 10 /31/0 1 GR-B 1.25E-02 1.30E-03 3. 31E-03 AP 02 62694 10 /31/0 1 GR-B 1. 4 6E-02 1.39E-03 3. 49E-03 AP 03 62695 10 /31/0 1 GR-B 1. 35E-02 1.54E-03 4. 02E-03 AP 04 62696 10 /31/0 1 GR-B 1. 36E-02 1.4 6E-03 3. 79E-03 AP 05 62697 10 /31/0 1 GR-B 1. 72E-02 1.57E-03 4 . OOE-03 AP 06 62698 10 /31/01 GR-B 1. 4 9E-02 1 . 42E-03 3. 58E-03 AP 07 62699 10 /31/01 GR-B 1. 34E-02 1.44E-03 3.73E-03 AP 08 62700 10 /31/01 GR-B 1.56E-02 1.43E-03 3. 58E-03 AP 01 62835 11/07/01 GR-B 2. 20E-02 1. 81E-03 4 16E-03 AP 02 62836 11/07/01 GR-B 1. 90E-02 1. 82E-03 4 43E-03 AP 03 62837 11/07/01 GR-B 2. 42E-02 1. 93E-03 4. 34E-03 AP 04 62838 11/07/01 GR-B 2. 16E-02 1. 81E-03 4 19E-03 AP 05 62839 11/07/01 GR-B 2.90E-02 2. 03E-03 4 44E-03 AP 06 62840 11/07/01 GR-B 2. 36E-02 1. 94E-03 4 47E-03 AP 07 62841 11/07/01 GR-B 2. 34E-02 1.83E-03 4 19E-03 AP 08 62842 11/07/01 GR-B 1. 95E-02 1. 85E-03 4 .48E-03
- Concentration Greater than 3 Standard Deviations 12
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 62927 11/14/01 GR-B 1. 32E-02 1. 32E-03 3. 32E-03 AP 02 62928 11/14/01 GR-B 1. 66E-02 1. 47E-03 3. 53E-03 AP 03 62929 11/14/01 GR-B 1. 65E-02 1. 48E-03 3. 61E-03 AP 04 62930 11/14/01 GR-B 1. 51E-02 1. 40E-03 3.4 8E-03 AP 05 62931 11/14/01 GR-B 2. 09E-02 1. 55E-03 3. 56E-03 AP 06 62932 11/14/01 GR-B 1. 75E-02 1. 52E-03 3. 73E-03 AP 07 62933 11/14/01 GR-B 1 .49E-02 1. 40E-03 3. 53E-03 AP 08 62934 11/14/01 GR-B 1. 45E-02 1. 47E-03 3. 68E-03 AP 01 63015 11/21/01 GR-B 3. 45E-02 1. 72E-03 3. 23E-03 AP 02 63016 11/21/01 GR-B 3. 81E-02 1. 85E-03 3. 40E-03 AP 03 63017 11/21/01 GR-B 3. 80E-02 1. 77E-03 3. 26E-03 AP 04 63018 11/21/01 GR-B 3. 69E-02 1. 69E-03 3. 14E-03 AP 05 63019 11/21/01 GR-B 4. 96E-02 1. 99E-03 3. 48E-03 AP 06 63020 11/21/01 GR-B 3. 55E-02 1. 80E-03 3. 4 1E-03 AP 07 63021 11/21/01 GR-B 3. 93E-02 1. 80E-03 3. 22E-03 AP 08 63022 11/21/01 GR-B 3. 39E-02 1. 79E-03 3. 50E-03 AP 01 63086 11/28/01 GR-B 2. 47E-02 1. 60E-03 3. 61E-03 AP 02 63087 11/28/01 GR-B 2. 50E-02 1. 64E-03 3.7 9E-03 AP 03 63088 11/28/01 GR-B 2. 60E-02 1 .73E-03 3. 88E-03 AP 04 63089 11/28/01 GR-B 2. 39E-02 1. 62E-03 3. 78E-03 AP 05 63090 11/28/01 GR-B 2. 97E-02 1. 76E-03 3. 83E-03 AP 06 63091 11/28/01 GR-B 2. 65E-02 1. 74E-03 3. 90E-03 AP 07 63092 11/28/01 GR-B 2.73E-02 1. 66E-03 3. 70E-03 AP 08 63093 11/28/01 GR-B 2. 58E-02 1. 73E-03 4 . OOE-03 AP 01 63197 12/05/01 GR-B 2.40E-02 1. 90E-03 4.40E-03 AP 02 63198 12/05/01 GR-B 2. 54E-02 2. OOE-03 4. 64E-03 AP 03 63199 12/05/01 GR-B 2. 61E-02 2. 03E-03 4. 63E-03 AP 04 63200 12/05/01 GR-B 2. 59E-02 2. OOE-03 4. 57E-03 AP 05 63201 12/05/01 GR-B 3. 48E-02 2 .18E-03 4. 67E-03 AP 06 63202 12/05/01 GR-B 2. 56E-02 2. 06E-03 4 75E-03 AP 07 63203 12/05/01 GR-B 2. 46E-02 1. 97E-03 4. 54E-03 AP 08 63204 12/05/01 GR-B 2. 69E-02 2.08E-03 4 76E-03 AP 01 63342 12/12/01 GR-B 2.40E-02 1.78E-03 4. 05E-03 AP 02 63343 12/12/01 GR-B 2.87E-02 1. 90E-03 4.16E-03 AP 03 63344 12/12/01 GR-B 2. 95E-02 1. 90E-03 4. 11E-03 AP 04 63345 12/12/01 GR-B 2. 84E-02 1. 85E-03 4. 05E-03 AP 05 63346 12/12/01 GR-B 3. 27E-02 2. 17E-03 4 .75E-03 AP 06 63347 12/12/01 GR-B 2. 69E-02 1. 95E-03 4.43E-03 AP 07 63348 12/12/01 GR-B 2.73E-02 1. 84E-03 4. 08E-03 AP 08 63349 12/12/01 GR-B 2.71E-02 1. 93E-03 4. 33E-03
- Concentration Greater than 3 Standard Deviations 13
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pci/cu.m) AIR PARTICULATES AP 01 63424 12/19/01 GR-B 1. 29E-02 1. 40E-03 3. 54E-03 AP 02 63425 12/19/01 GR-B 1. 88E-02 1. 53E-03 3. 69E-03 AP 03 63426 12/19/01 GR-B 1.7 6E-02 1. 53E-03 3. 77E-03 AP 04 63427 12/19/01 GR-B 1. 72E-02 1. 54E-03 3. 68E-03 AP 05 63428 12/19/01 GR-B 2. 33E-02 1.73E-03 4. 05E-03 AP 06 63429 12/19/01 GR-B 1.71E-02 1. 58E-03 3.7 6E-03 AP 07 63430 12/19/01 GR-B 1. 80E-02 1. 53E-03 3. 72E-03 AP 08 63431 12/19/01 GR-B 1. 81E-02 1. 55E-03 3. 81E-03 AP 01 63520 12/26/01 GR-B 2. 09E-02 1.55E-03 3. 70E-03 AP 02 63521 12/26/01 GR-B 2. 09E-02 1.58E-03 3. 82E-03 AP 03 63522 12/26/01 GR-B 2. 1OE-02 1.56E-03 3. 80E-03 AP 04 63523 12/26/01 GR-B 2. 27E-02 1.56E-03 3. 70E-03 AP 05 63524 12/26/01 GR-B 2. 59E-02 1.70E-03 4 . OOE-03 AP 06 63525 12/26/01 GR-B 2. 34E-02 1. 65E-03 3. 93E-03 AP 07 63526 12/26/01 GR-B 2. 13E-02 1. 60E-03 3. 88E-03 AP 08 63527 12/26/01 GR-B 2. 30E-02 1. 65E-03 3. 93E-03 AP 01 63585 01/02/02 GR-B 2. 62E-02 1. 64E-03 3. 83E-03 AP 02 63586 01/02/02 GR-B 2 .48E-02 1. 69E-03 3. 91E-03 AP 03 63587 01/02/02 GR-B 2.80E-02 1.71E-03 3. 84E-03 AP 04 63588 01/02/02 GR-B 2.81E-02 1. 65E-03 3. 77E-03 AP 05 63589 01/02/02 GR-B 2. 92E-02 1.79E-03 4 . 1OE-03 AP 06 63590 01/02/02 GR-B 2. 66E-02 1.78E-03 4. 06E-03 AP 07 63591 01/02/02 GR-B 2.89E-02 1.77E-03 4 .07E-03 AP 08 63592 01/02/02 GR-B 2.55E-02 1.70E-03 4 .07E-03
- Concentration Greater than 3 Standard Deviations 14
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 59647 03/28/01 Th-232 -1.23E-04 1.14E-03 4.97E-03 AP 01 59647 03/28/01 Ag-IIOM 2.01E-04 6.02E-04 2.41E-03 AP 01 59647 03/28/01 Ba-140 2.17E-02 1.53E-02 2.93E-02 AP 01 59647 03/28/01 Be-7 6.25E-02 1.56E-02 4.26E-02
- AP 01 59647 03/28/01 Ce-141 1.27E-03 1.37E-03 4.79E-03 AP 01 59647 03/28/01 Ce-144 -1.78E-03 1.43E-03 5.76E-03 AP 01 59647 03/28/01 Co-57 1.72E-04 1.65E-04 5.69E-04 AP 01 59647 03/28/01 Co-58 -3.08E-04 7.23E-04 3.21E-03 AP 01 59647 03/28/01 Co-60 -1.99E-04 1.99E-04 1.38E-03 AP 01 59647 03/28/01 Cr-51 -1.98E-02 1.75E-02 7.23E-02 AP 01 59647 03/28/01 Cs-134 -1.95E-04 2.93E-04 1.45E-03 AP 01 59647 03/28/01 Cs-137 1.34E-04 3.39E-04 1.32E-03 AP 01 59647 03/28/01 Fe-59 1.27E-03 2.62E-03 1.13E-02 AP 01 59647 03/28/01 1-131 -4.50E-02 0.10E+00 0.41E+00 AP 01 59647 03/28/01 K-40 1.17E-03 5.36E-03 2.18E-02 AP 01 59647 03/28/01 Mn-54 -2.62E-04 4.14E-04 1.85E-03 AP 01 59647 03/28/01 Ru-103 -3.19E-04 8.45E-04 3.83E-03 AP 01 59647 03/28/01 Ru-106 3.54E-03 2.85E-03 9.74E-03 AP 01 59647 03/28/01 Sb-124 2.42E-03 1.71E-03 3.27E-03 AP 01 59647 03/28/01 Se-75 0.OOE+00 4.88E-04 1.87E-03 AP 01 59647 03/28/01 Zn-65 -7.29E-04 7.29E-04 3.92E-03 AP 01 59647 03/28/01 Zr-95 1.24E-03 1.60E-03 5.87E-03 AP 01 61241 06/27/01 Th-232 9.88E-04 1.05E-03 3.82E-03 AP 01 61241 06/27/01 Ag-IIOM -9.29E-05 4.58E-04 2.07E-03 AP 01 61241 06/27/01 Ba-140 4.60E-03 3.57E-02 0.16E+00 AP 01 61241 06/27/01 Be-7 8.41E-02 1.60E-02 3.76E-02
- AP 01 61241 06/27/01 Ce-141 -1.36E-03 1.59E-03 6.44E-03 AP 01 61241 06/27/01 Ce-144 -1.38E-03 1.45E-03 5.74E-03 AP 01 61241 06/27/01 Co-57 1.28E-04 1.72E-04 6.06E-04 AP 01 61241 06/27/01 Co-58 1.52E-04 7.23E-04 2.95E-03 AP 01 61241 06/27/01 Co-60 4.34E-04 4.34E-04 1.56E-03 AP 01 61241 06/27/01 Cr-51 2.32E-02 1.82E-02 6.14E-02 AP 01 61241 06/27/01 Cs-134 -6.10E-04 3.OOE-04 1.65E-03 AP 01 61241 06/27/01 Cs-137 -2.29E-04 4.13E-04 1.69E-03 AP 01 61241 06/27/01 Fe-59 2.78E-03 3.06E-03 1.15E-02 AP 01 61241 06/27/01 1-131 0.OOE+00 0.18E+00 0.71E+00 AP 01 61241 06/27/01 K-40 -5.56E-03 3.78E-03 2.OOE-02 AP 01 61241 06/27/01 Mn-54 5.14E-04 3.32E-04 1.05E-03 AP 01 61241 06/27/01 Ru-103 -6.89E-04 1.29E-03 5.46E-03 AP 01 61241 06/27/01 Ru-106 -8.99E-04 3.38E-03 1.39E-02 AP 01 61241 06/27/01 Sb-124 1.18E-03 2.04E-03 8.66E-03 AP 01 61241 06/27/01 Se-75 7.66E-04 5.42E-04 1.80E-03 AP 01 61241 06/27/01 Zn-65 -1.34E-03 8.20E-04 4.39E-03 AP 01 61241 06/27/01 Zr-95 -1.80E-03 1.36E-03 6.59E-03
- Concentration Greater than 3 Standard Deviations 15
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 01 62423 09/26/01 Th-232 2. 12E-03 1. 67E-03 5. 66E-03 AP 01 62423 09/26/01 Ag-IIOM -1. 05E-03 5. 55E-04 2. 96E-03 AP 01 62423 09/26/01 Be-7 7. 90E-02 1. 27E-02 2.2 9E-02 AP 01 62423 09/26/01 Ce-141 1. 38E-03 1. 32E-03 4.53E-03 AP 01 62423 09/26/01 Ce-144 -3. 53E-03 1. 36E-03 6. 04E-03 AP 01 62423 09/26/01 Co-57 -1. 41E-04 1. 44E-04 5. 96E-04 AP 01 62423 09/26/01 Co-58 -5. 32E-04 6. 52E-04 3. 08E-03 AP 01 62423 09/26/01 Co-60 -7. 15E-05 4. 97E-04 2. 20E-03 AP 01 62423 09/26/01 Cr-51 -5.2 6E-03 1. 29E-02 5. 13E-02 AP 01 62423 09/26/01 Cs-134 -6. 94E-05 3. 42E-04 1.55E-03 AP 01 62423 09/26/01 Cs-137 3. 97E-04 3.20E-04 1.09E-03 AP 01 62423 09/26/01 Fe-59 -1. 62E-03 2.44E-03 1.29E-02 AP 01 62423 09/26/01 1-131 5. 96E-02 3. 30E-02 0. 10E+00 AP 01 62423 09/26/01 K-40 2 .74E-03 5.59E-03 2. 20E-02 AP 01 62423 09/26/01 Mn-54 -4.13E-04 4.57E-04 2. 07E-03 AP 01 62423 09/26/01 Ru-103 -8. 35E-04 9. 23E-04 4. 18E-03 AP 01 62423 09/26/01 Ru-106 6. 79E-04 2.44E-03 1. 03E-02 AP 01 62423 09/26/01 Sb-124 0. OOE+00 2.78E-03 1 22E-02 AP 01 62423 09/26/01 Se-75 -9. 19E-I1 5. 10E-04 1 . 94E-03 AP 01 62423 09/26/01 Zn-65 -1. 52E-03 1.08E-03 5 .37E-03 AP 01 62423 09/26/01 Zr-95 9. 61E-04 1. 00E-03 3.70E-03 AP 01 63619 01/02/02 Th-232 -1.27E-03 8.45E-04 4.42E-03 AP 01 63619 01/02/02 Ag-IIGM -3. 80E-05 3.23E-04 1.50E-03 AP 01 63619 01/02/02 Ba-140 -1. 20E-02 5. 98E-03 3.4 6E-02 AP 01 63619 01/02/02 Be-7 6. 48E-02 1. 06E-02 2.31E-02
- AP 01 63619 01/02/02 Ce-141 -3.87E-04 1. 20E-03 4.41E-03 AP 01 63619 01/02/02 Ce-144 -3. 38E-03 1. 4 1E-03 5. 85E-03 AP 01 63619 01/02/02 Co-57 1. 98E-04 1.83E-04 6.23E-04 AP 01 63619 01/02/02 Co-58 0. 00E+00 4. 01E-04 1.76E-03 AP 01 63619 01/02/02 Co-60 1. 38E-04 3.65E-04 1.48E-03 AP 01 63619 01/02/02 Cr-51 6. 96E-03 1. 15E-02 4. 06E-02 AP 01 63619 01/02/02 Cs-134 4. 09E-04 2.89E-04 9. 50E-04 AP 01 63619 01/02/02 Cs-137 8. 07E-05 2.42E-04 9.70E-04 AP 01 63619 01/02/02 Fe-59 -1. 69E-03 1. 19E-03 7.84E-03 AP 01 63619 01/02/02 1-131 -6. 60E-03 1. 34E-02 5.42E-02 AP 01 63619 01/02/02 K-40 -1. 81E-03 3. 18E-03 1.54E-02 AP 01 63619 01/02/02 Mn-54 -1. 63E-04 3. 22E-04 1.41E-03 AP 01 63619 01/02/02 Ru-103 -5. 55E-04 6. 66E-04 2. 93E-03 AP 01 63619 01/02/02 Ru-106 -7. 53E-04 3. lOE-03 1.25E-02 AP 01 63619 01/02/02 Sb-124 1. 43E-03 1. 55E-03 5.80E-03 AP 01 63619 01/02/02 Se-75 3. OOE-04 4. 94E-04 1.75E-03 AP 01 63619 01/02/02 Zn-65 -3. 82E-04 8. 13E-04 3. 62E-03 AP 01 63619 01/02/02 Zr-95 2. 94E-04 8.82E-04 3. 53E-03
- Concentration Greater than 3 Standard Deviations 16
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 02 59648 03/28/01 Th-232 8. 06E-04 1.01E-03 3. 85E-03 AP 02 59648 03/28/01 Ag-IIOM -4 .76E-05 5. 89E-04 2. 48E-03 AP 02 59648 03/28/01 Be-7 0. 10E+00 1. 50E-02 2 70E-02
- AP 02 59648 03/28/01 Ce-141 -6. 61E-04 1.52E-03 5. 90E-03 AP 02 59648 03/28/01 Ce-144 3. 54E-04 1.54E-03 5. 62E-03 AP 02 59648 03/28/01 Co-57 -7.7 6E-05 1. 77E-04 6. 82E-04 AP 02 59648 03/28/01 Co-58 -8. 79E-05 6. 56E-04 2 84E-03 AP 02 59648 03/28/01 Co-60 1. 03E-04 4. 61E-04 1. 90E-03 AP 02 59648 03/28/01 Cr-51 1. 96E-02 1.73E-02 5. 92E-02 AP 02 59648 03/28/01 Cs-134 6. 18E-05 3. 29E-04 1. 38E-03 AP 02 59648 03/28/01 Cs-137 -3. 20E-05 2. 09E-04 9. 71E-04 AP 02 59648 03/28/01 Fe-59 1. 02E-03 3. 19E-03 1. 34E-02 AP 02 59648 03/28/01 1-131 0. 18E+00 0. 11E+00 0. 37E+00 AP 02 59648 03/28/01 K-40 1. 77E-04 3. 86E-03 1. 70E-02 AP 02 59648 03/28/01 Mn-54 7 77E-05 3. 69E-04 1. 51E-03 AP 02 59648 03/28/01 Ru-103 -9. 29E-04 1. 03E-03 4. 65E-03 AP 02 59648 03/28/01 Ru-106 -9. 57E-04 2.57E-03 1. 15E-02 AP 02 59648 03/28/01 Sb-124 1. 12E-03 2. 50E-03 1. 04E-02 AP 02 59648 03/28/01 Se-75 -3. 82E-04 5.05E-04 2 . 04E-03 AP 02 59648 03/28/01 Zn-65 -3. 42E-04 5. 93E-04 3. 18E-03 AP 02 59648 03/28/01 Zr-95 -5. 37E-04 1.26E-03 5. 60E-03 AP 02 61242 06/27/01 Th-232 7 . 25E-04 1. 08E-03 4 16E-03 AP 02 61242 06/27/01 Ag-IIOM 5. 82E-04 4.34E-04 1. 43E-03 AP 02 61242 06/27/01 Ba-140 0. OOE+00 2.37E-02 0. 12E+00 AP 02 61242 06/27/01 Be-7 0. 12E+00 1.59E-02 2. 19E-02
- AP 02 61242 06/27/01 Ce-141 1 . 50E-04 1.74E-03 6. 46E-03 AP 02 61242 06/27/01 Ce-144 1. 17E-03 1. 14E-03 3. 94E-03 AP 02 61242 06/27/01 Co-57 1. 67E-04 1.38E-04 4.71E-04 AP 02 61242 06/27/01 Co-58 -4 . 1OE-04 4. 59E-04 2 .53E-03 AP 02 61242 06/27/01 Co-60 -2. 13E-05 2. 56E-04 1. 33E-03 AP 02 61242 06/27/01 Cr-51 -1. 13E-02 1.88E-02 7.56E-02 AP 02 61242 06/27/01 Cs-134 -4. 62E-05 3. 45E-04 1. 49E-03 AP 02 61242 06/27/01 Cs-137 3. 44E-04 2. 77E-04 9. 47E-04 AP 02 61242 06/27/01 Fe-59 1. 39E-03 2. 87E-03 1.24E-02 AP 02 61242 06/27/01 1-131 -0. 13E+00 0. 17E+00 0. 73E+00 AP 02 61242 06/27/01 K-40 1. 96E-03 4. 21E-03 1.71E-02 AP 02 61242 06/27/01 Mn-54 1. 26E-04 2. 81E-04 1. 17E-03 AP 02 61242 06/27/01 Ru-103 -6. 89E-04 1. 29E-03 5 47E-03 AP 02 61242 06/27/01 Ru-106 -8 .84E-03 3. 61E-03 1 .76E-02 AP 02 61242 06/27/01 Sb-124 -2. 58E-03 2. 58E-03 1 .39E-02 AP 02 61242 06/27/01 Se-75 1. 84E-04 4 11E-04 1 .53E-03 AP 02 61242 06/27/01 Zn-65 -1. 78E-03 1. 07E-03 5 . 34E-03 AP 02 61242 06/27/01 Zr-95 5. 81E-04 9. 90E-04 4 . 03E-03
- Concentration Greater than 3 Standard Deviations 17
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE . STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 02 62424 09/26/01 Th-232 1.33E-03 1.42E-03 5.05E-03 AP 02 62424 09/26/01 Ag-IlOM -3.42E-04 5.70E-04 2.50E-03 AP 02 62424 09/26/01 Ba-140 1.06E-02 1. 14E-02 4.24E-02 AP 02 62424 09/26/01 Be-7 9.03E-02 1.4 1E-02 3.18E-02
- AP 02 62424 09/26/01 Ce-141 7.85E-04 1. 23E-03 4.34E-03 AP 02 62424 09/26/01 Ce-144 1.28E-03 1. 39E-03 4.81E-03 AP 02 62424 09/26/01 Co-57 2.14E-04 1. 95E-04 6. 65E-04 AP 02 62424 09/26/01 Co-58 1.45E-04 6. 29E-04 2. 52E-03 AP 02 62424 09/26/01 Co-60 1.34E-03 5. 62E-04 1. 51E-03 AP 02 62424 09/26/01 Cr-51 0.00E+00 1. 18E-02 4. 50E-02 AP 02 62424 09/26/01 Cs-134 -2.84E-05 3. 52E-04 1.48E-03 AP 02 62424 09/26/01 Cs-137 -2.53E-04 2. 80E-04 1.29E-03 AP 02 62424 09/26/01 Fe-59 -1.43E-03 2. 51E-03 1.20E-02 AP 02 62424 09/26/01 1-131 -4.33E-02 2.88E-02 0. 13E+00 AP 02 62424 09/26/01 K-40 -2.38E-03 4. 26E-03 1. 95E-02 AP 02 62424 09/26/01 Mn-54 -5.06E-04 4. 38E-04 1. 95E-03 AP 02 62424 09/26/01 Ru-103 0.00E+00 7. 35E-04 3. 05E-03 AP 02 62424 09/26/01 Ru-106 5.61E-04 2. 01E-03 8. 50E-03 AP 02 62424 09/26/01 Sb-124 0.00E+00 1. 80E-03 8. 37E-03 AP 02 62424 09/26/01 Se-75 2.48E-04 5.42E-04 1. 94E-03 AP 02 62424 09/26/01 Zn-65 -2.46E-03 1. 15E-03 5.57E-03 AP 02 62424 09/26/01 Zr-95 2.19E-04 1. 04E-03 4.25E-03 AP 02 63620 01/02/02 Th-232 6.91E-04 1.39E-03 5.27E-03 AP 02 63620 01/02/02 Ag-IlOM 0.OOE+00 4.85E-04 2. 06E-03 AP 02 63620 01/02/02 Ba-140 -3.21E-03 5. 56E-03 2.98E-02 AP 02 63620 01/02/02 Be-7 8.34E-02 1. 14E-02 2.05E-02
- AP 02 63620 01/02/02 Ce-141 5.17E-04 8 .32E-04 2. 98E-03 AP 02 63620 01/02/02 Ce-144 -4.44E-04 1 .06E-03 4.14E-03 AP 02 63620 01/02/02 Co-57 -2.34E-04 1.21E-04 5.29E-04 AP 02 63620 01/02/02 Co-58 -7.80E-04 4. 34E-04 2. 39E-03 AP 02 63620 01/02/02 Co-60 3.21E-04 2 . 27E-04 4.34E-04 AP 02 63620 01/02/02 Cr-51 -3.51E-03 8. 22E-03 3.30E-02 AP 02 63620 01/02/02 Cs-134 1.86E-04 3. 59E-04 1.39E-03 AP 02 63620 01/02/02 Cs-137 -5.94E-05 2.74E-04 1. 17E-03 AP 02 63620 01/02/02 Fe-59 -2.33E-03 2. 15E-03 1. 13E-02 AP 02 63620 01/02/02 1-131 6.22E-03 1.16E-02 4. 39E-02 AP 02 63620 01/02/02 K-40 2.19E-03 4. 51E-03 1 .78E-02 AP 02 63620 01/02/02 Mn-54 4.51E-04 3. 19E-04 1.05E-03 AP 02 63620 01/02/02 Ru-103 -1.20E-03 6. 93E-04 3. 33E-03 AP 02 63620 01/02/02 Ru-106 -1.38E-03 2.40E-03 1.09E-02 AP 02 63620 01/02/02 Sb-124 8.92E-04 2. 00E-03 8. 28E-03 AP 02 63620 01/02/02 Se-75 1.49E-04 2. 99E-04 1. 12E-03 AP 02 63620 01/02/02 Zn-65 -9.40E-04 7 . 01E-04 3. 77E-03 AP 02 63620 01/02/02 Zr-95 -4.10E-04 9. 62E-04 4 .28E-03
- Concentration Greater than 3 Standard Deviations 18
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 03 59649 03/28/01 Th-232 7.72E-04 1. 52E-03 5. 80E-03 AP 03 59649 03/28/01 Ag-IIOM -4.12E-04 7. 14E-04 3. 09E-03 AP 03 59649 03/28/01 Ba-140 2.27E-02 2 .78E-02 0. 11E+00 AP 03 59649 03/28/01 Be-7 8.52E-02 1. 34E-02 2.13E-02
- AP 03 59649 03/28/01 Ce-141 5.84E-04 1. 45E-03 5. 28E-03 AP 03 59649 03/28/01 Ce-144 1.51E-04 1. 33E-03 4. 95E-03 AP 03 59649 03/28/01 Co-57 -8.86E-05 1. 34E-04 5. 45E-04 AP 03 59649 03/28/01 Co-58 -7.57E-04 8. 03E-04 3. 69E-03 AP 03 59649 03/28/01 Co-60 1.84E-04 1. 84E-04 4. 99E-04 AP 03 59649 03/28/01 Cr-51 6.57E-03 1. 47E-02 5. 47E-02 AP 03 59649 03/28/01 Cs-134 1.66E-04 2. 83E-04 1. 15E-03 AP 03 59649 03/28/01 Cs-137 -1.87E-04 3. 35E-04 1. 47E-03 AP 03 59649 03/28/01 Fe-59 -3.77E-04 3. 21E-03 1. 49E-02 AP 03 59649 03/28/01 1-131 0.11E+00 7.44E-02 0.24E+00 AP 03 59649 03/28/01 K-40 4.23E-03 4. 94E-03 1. 84E-02 AP 03 59649 03/28/01 Mn-54 1.34E-04 4. 02E-04 1. 61E-03 AP 03 59649 03/28/01 Ru-103 0.OOE+00 9. 09E-04 3.8 6E-03 AP 03 59649 03/28/01 Ru-106 -1.79E-03 3. 22E-03 1.4 1E-02 AP 03 59649 03/28/01 Sb-124 2.54E-03 1.79E-03 3. 43E-03 AP 03 59649 03/28/01 Se-75 2.85E-04 4. 14E-04 1. 51E-03 AP 03 59649 03/28/01 Zn-65 -7.54E-04 7. 54E-04 4.06E-03 AP 03 59649 03/28/01 Zr-95 2.30E-04 1. 22E-03 5. 13E-03 AP 03 61243 06/27/01 Th-232 2.85E-04 1.48E-03 5.91E-03 AP 03 61243 06/27/01 Ag-IIOM -2.14E-04 6.41E-04 2.80E-03 AP 03 61243 06/27/01 Ba-140 3.60E-02 3. 60E-02 0. 13E+00 AP 03 61243 06/27/01 Be-7 9.53E-02 1. 68E-02 3.55E-02
- AP 03 61243 06/27/01 Ce-141 -1.43E-03 1. 67E-03 6.79E-03 AP 03 61243 06/27/01 Ce-144 3.21E-04 1. 36E-03 5. 04E-03 AP 03 61243 06/27/01 Co-57 2.66E-04 2. OOE-04 6.70E-04 AP 03 61243 06/27/01 Co-58 -4.18E-04 6. 27E-04 3. 1OE-03 AP 03 61243 06/27/01 Co-60 -4.39E-04 4. 04E-04 2. 13E-03 AP 03 61243 06/27/01 Cr-51 4.26E-03 1.8 6E-02 7. 10E-02 AP 03 61243 06/27/01 Cs-134 -4.43E-04 3. 50E-04 1. 77E-03 AP 03 61243 06/27/01 Cs-137 3.47E-05 3. 37E-04 1. 37E-03 AP 03 61243 06/27/01 Fe-59 -3.88E-03 2. 75E-03 1.71E-02 AP 03 61243 06/27/01 1-131 0.20E+00 0. 20E+00 0. 70E+00 AP 03 61243 06/27/01 K-40 2.09E-03 3. 28E-03 1. 36E-02 AP 03 61243 06/27/01 Mn-54 0.OOE+00 3. 40E-04 1.4 9E-03 AP 03 61243 06/27/01 Ru-103 3.86E-04 1. 16E-03 4. 64E-03 AP 03 61243 06/27/01 Ru-106 -5.94E-03 2. 66E-03 1.47E-02 AP 03 61243 06/27/01 Sb-124 1.39E-03 1. 39E-03 3.7 6E-03 AP 03 61243 06/27/01 Se-75 -6.28E-04 6. 1OE-04 2. 46E-03 AP 03 61243 06/27/01 Zn-65 -1.17E-03 1. 03E-03 5. 09E-03 AP 03 61243 06/27/01 Zr-95 1.35E-03 1. 69E-03 6. 24E-03
- Concentration Greater than 3 Standard Deviations 19
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 03 62425 09/26/01 Th-232 3.49E-04 1. 37E-03 5.4 9E-03 AP 03 62425 09/26/01 Ag-IIOM 5. 88E-04 5. 19E-04 1. 82E-03 AP 03 62425 09/26/01 Ba-140 -5.77E-03 5. 77E-03 4.25E-02 AP 03 62425 09/26/01 Be-7 8. 53E-02 1.4 1E-02 3.16E-02
- AP 03 62425 09/26/01 Ce-141 -4.43E-04 1. 18E-03 4 .51E-03 AP 03 62425 09/26/01 Ce-144 5.43E-04 1.28E-03 4. 63E-03 AP 03 62425 09/26/01 Co-57 -1. 02E-04 1. 34E-04 5.45E-04 AP 03 62425 09/26/01 Co-58 -5. 23E-04 5.32E-04 2. 67E-03 AP 03 62425 09/26/01 Co-60 8. 58E-04 5. 58E-04 1.79E-03 AP 03 62425 09/26/01 Cr-51 -7 .15E-03 1. 14E-02 4. 65E-02 AP 03 62425 09/26/01 Cs-134 2 . 75E-04 2.51E-04 8. 96E-04 AP 03 62425 09/26/01 Cs-137 -1. 67E-04 2 . 91E-04 1. 32E-03 AP 03 62425 09/26/01 Fe-59 -1. 54E-03 2. 31E-03 1. 22E-02 AP 03 62425 09/26/01 1-131 4. 64E-02 3. 28E-02 0. 11E+00 AP 03 62425 09/26/01 K-40 1. 30E-02 6.33E-03 1. 83E-02 AP 03 62425 09/26/01 Mn-54 6. 42E-04 4. 63E-04 1. 54E-03 AP 03 62425 09/26/01 Ru-103 7 66E-04 7. 66E-04 2. 75E-03 AP 03 62425 09/26/01 Ru-106 -2. 98E-03 3. 59E-03 1. 56E-02 AP 03 62425 09/26/01 Sb-124 -1.09E-03 2 .43E-03 1. 17E-02 AP 03 62425 09/26/01 Se-75 8. 71E-04 4 444E-04 1. 38E-03 AP 03 62425 09/26/01 Zn-65 -3. 59E-04 8. 02E-04 3. 86E-03 AP 03 62425 09/26/01 Zr-95 -9. 93E-04 8 01E-04 4 .42E-03 AP 03 63621 01/02/02 Th-232 1. 81E-03 1. 31E-03 4.35E-03 AP 03 63621 01/02/02 Ag-IIOM -1.75E-04 3. 92E-04 1.89E-03 AP 03 63621 01/02/02 Ba-140 -3.20E-03 8.48E-03 3.85E-02 AP 03 63621 01/02/02 Be-7 7 .83E-02 1. 1OE-02 1.85E-02
- AP 03 63621 01/02/02 Ce-141 3. 59E-04 8.82E-04 3.21E-03 AP 03 63621 01/02/02 Ce-144 1. 56E-03 1. 16E-03 3.89E-03 AP 03 63621 01/02/02 Co-57 -1. 47E-04 1.35E-04 5 . 53E-04 AP 03 63621 01/02/02 Co-58 -6. 11E-04 4.83E-04 2.45E-03 AP 03 63621 01/02/02 Co-60 -9. 1OE-04 4. 07E-04 2.28E-03 AP 03 63621 01/02/02 Cr-51 -1. 85E-03 8. 46E-03 3. 35E-02 AP 03 63621 01/02/02 Cs-134 4. 85E-04 2 .82E-04 8.13E-04 AP 03 63621 01/02/02 Cs-137 -4.76E-04 3.26E-04 1. 52E-03 AP 03 63621 01/02/02 Fe-59 -3. 71E-04 2.58E-03 1. 14E-02 AP 03 63621 01/02/02 1-131 -6. 50E-03 1.45E-02 5.89E-02 AP 03 63621 01/02/02 K-40 -3. 01E-03 4. 64E-03 2. 13E-02 AP 03 63621 01/02/02 Mn-54 1. 16E-04 3.83E-04 1. 51E-03 AP 03 63621 01/02/02 Ru-103 -6. 24E-04 5.51E-04 2. 73E-03 AP 03 63621 01/02/02 Ru-106 6. 85E-03 2.42E-03 2. 32E-03 AP 03 63621 01/02/02 Sb-124 3.57E-03 1.78E-03 2.41E-03 AP 03 63621 01/02/02 Se-75 -7 . 10E-04 4. 10E-04 1.77E-03 AP 03 63621 01/02/02 Zn-65 3. 18E-04 7 . 11E-04 2. 95E-03 AP 03 63621 01/02/02 Zr-95 3.79E-04 5. 61E-04 2. 33E-03
- Concentration Greater than 3 Standard Deviations 20
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 04 59650 03/28/01 Th-232 2.44E-03 1.56E-03 5.04E-03 AP 04 59650 03/28/01 Ag-IIOM 0.OOE+00 6.44E-04 2.67E-03 AP 04 59650 03/28/01 Ba-140 -1. 1OE-02 1. 1OE-02 8. 08E-02 AP 04 59650 03/28/01 Be-7 6. 48E-02 1. 44E-02 3.57E-02
- AP 04 59650 03/28/01 Ce-141 3. 52E-03 1. 52E-03 4. 58E-03 AP 04 59650 03/28/01 Ce-144 -2. 69E-03 1. 41E-03 5. 92E-03 AP 04 59650 03/28/01 Co-57 2. 35E-05 1. 46E-04 5. 50E-04 AP 04 59650 03/28/01 Co-58 5. 93E-04 6. 75E-04 2. 50E-03 AP 04 59650 03/28/01 Co-60 8. 76E-04 4. 84E-04 1. 40E-03 AP 04 59650 03/28/01 Cr-51 -3. 35E-03 1. 53E-02 6. 07E-02 AP 04 59650 03/28/01 Cs-134 3. 29E-05 2.48E-04 1. 14E-03 AP 04 59650 03/28/01 Cs-137 2. 88E-04 2 . 35E-04 8. 07E-04 AP 04 59650 03/28/01 Fe-59 -1. 84E-03 2.77E-03 1. 4 6E-02 AP 04 59650 03/28/01 1-131 6. 83E-02 9. 92E-02 0. 36E+00 AP 04 59650 03/28/01 K-40 6.55E-03 5. 13E-03 1. 74E-02 AP 04 59650 03/28/01 Mn-54 6. 63E-04 4.40E-04 1. 43E-03 AP 04 59650 03/28/01 Ru-103 6. 47E-04 1. 12E-03 4. 24E-03 AP 04 59650 03/28/01 Ru-106 -4.07E-03 3. 60E-03 1. 62E-02 AP 04 59650 03/28/01 Sb-124 0. OOE+00 2. 45E-03 1. 14E-02 AP 04 59650 03/28/01 Se-75 -4 .85E-04 4.45E-04 1.89E-03 AP 04 59650 03/28/01 Zn-65 0. OOE+00 1. 05E-03 4 .44E-03 AP 04 59650 03/28/01 Zr-95 -2.86E-04 9. 47E-04 4 57E-03 AP 04 61244 06/27/01 Th-232 -5. 78E-04 1. 13E-03 5. 14E-03 AP 04 61244 06/27/01 Ag-IIOM 7. 25E-04 6. 88E-04 2.43E-03 AP 04 61244 06/27/01 Ba-140 -3. 96E-02 4. 62E-02 0. 22E+00 AP 04 61244 06/27/01 Be-7 0. 10E+00 1.81E-02 4.17E-02
- AP 04 61244 06/27/01 Ce-141 -2. OOE-03 2. OOE-03 7. 99E-03 AP 04 61244 06/27/01 Ce-144 -2. 06E-04 1. 69E-03 6. 26E-03 AP 04 61244 06/27/01 Co-57 -2. 65E-04 1. 70E-04 7.16E-04 AP 04 61244 06/27/01 Co-58 -6. 55E-05 8. 11E-04 3.4 1E-03 AP 04 61244 06/27/01 Co-60 -3. 82E-04 2. 70E-04 1 . 68E-03 AP 04 61244 06/27/01 Cr-51 1. 25E-02 2. 39E-02 8.63E-02 AP 04 61244 06/27/01 Cs-134 -1. 60E-04 3. 75E-04 1. 67E-03 AP 04 61244 06/27/01 Cs-137 -3. 78E-04 2. 93E-04 1.42E-03 AP 04 61244 06/27/01 Fe-59 -4 .18E-03 4. 86E-03 2.24E-02 AP 04 61244 06/27/01 1-131 -0.29E+00 0.29E+00 1. 15E+00 AP 04 61244 06/27/01 K-40 7.23E-03 6. 74E-03 2. 35E-02 AP 04 61244 06/27/01 Mn-54 -3. 90E-04 4. 14E-04 1. 90E-03 AP 04 61244 06/27/01 Ru-103 0. OOE+00 1.74E-03 6.72E-03 AP 04 61244 06/27/01 Ru-106 3. 87E-03 4.23E-03 1.50E-02 AP 04 61244 06/27/01 Sb-124 -1. 27E-03 1.27E-03 9. 31E-03 AP 04 61244 06/27/01 Se-75 2. 06E-04 6.01E-04 2.20E-03 AP 04 61244 06/27/01 Zn-65 -3. 24E-03 1. 65E-03 7.46E-03 AP 04 61244 06/27/01 Zr-95 2. OOE-03 1. 16E-03 3.35E-03
- Concentration Greater than 3 Standard Deviations 21
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 04 62426 09/26/01 Th-232 -5. 86E-04 1. 33E-03 5.84E-03 AP 04 62426 09/26/01 Ag-11OM 0. OOE+00 4. 89E-04 2. 15E-03 AP 04 62426 09/26/01 Ba-140 5. 76E-03 5. 76E-03 1.56E-02 AP 04 62426 09/26/01 Be-7 8. 85E-02 1. 28E-02 2. 02E-02
- AP 04 62426 09/26/01 Ce-141 3. 03E-04 1. 17E-03 4.31E-03 AP 04 62426 09/26/01 Ce-144 -1. 32E-03 1.29E-03 5. 22E-03 AP 04 62426 09/26/01 Co-57 -1. 53E-04 1. 66E-04 6. 62E-04 AP 04 62426 09/26/01 Co-58 -1. 12E-04 5.54E-04 2. 50E-03 AP 04 62426 09/26/01 Co-60 -2. 27E-05 2.73E-04 1. 41E-03 AP 04 62426 09/26/01 Cr-51 2. OOE-02 1.23E-02 3. 97E-02 AP 04 62426 09/26/01 Cs-134 4. 63E-04 4.19E-04 1. 47E-03 AP 04 62426 09/26/01 Cs-137 -6. 52E-04 3. 84E-04 1. 80E-03 AP 04 62426 09/26/01 Fe-59 4 .79E-03 3.09E-03 9. 63E-03 AP 04 62426 09/26/01 1-131 7.28E-02 3. 52E-02 0. 11E+00 AP 04 62426 09/26/01 K-40 6. 23E-03 5. 91E-03 2. 09E-02 AP 04 62426 09/26/01 Mn-54 -6. 55E-04 4.72E-04 2. 18E-03 AP 04 62426 09/26/01 Ru-103 -1. 06E-03 9. 17E-04 4.20E-03 AP 04 62426 09/26/01 Ru-106 1. 13E-03 3. 60E-03 1. 40E-02 AP 04 62426 09/26/01 Sb-124 -1. 08E-03 1. 08E-03 7. 95E-03 AP 04 62426 09/26/01 Se-75 4.59E-04 4.59E-04 1. 60E-03 AP 04 62426 09 /26/01 Zn-65 -3. 62E-04 9. 58E-04 4. 35E-03 AP 04 62426 09/26/01 Zr-95 -5. 08E-04 1. 19E-03 5. 29E-03 AP 04 63622 01/02/02 Th-232 -1.45E-03 1.33E-03 5.87E-03 AP 04 63622 01/02/02 Ag-lIOM -9.20E-04 5.56E-04 2.62E-03 AP 04 63622 01/02/02 Ba-140 -3.57E-03 6. 51E-03 3. 12E-02 AP 04 63622 01/02/02 Be-7 5.58E-02 1. 06E-02 2. 60E-02
- AP 04 63622 01/02/02 Ce-141 1.74E-03 1. 39E-03 4. 67E-03 AP 04 63622 01/02/02 Ce-144 -1.85E-03 1. 67E-03 6. 35E-03 AP 04 63622 01/02/02 Co-57 3.93E-06 2. 02E-04 7 . 28E-04 AP 04 63622 01/02/02 Co-58 3.30E-04 5. 72E-04 2. 17E-03 AP 04 63622 01/02/02 Co-60 -2.78E-04 3. 94E-04 1 83E-03 AP 04 63622 01/02/02 Cr-51 5.90E-03 1. 09E-02 3 87E-02 AP 04 63622 01/02/02 Cs-134 -1.03E-04 2. 31E-04 1 11E-03 AP 04 63622 01/02/02 Cs-137 1.63E-04 3. 05E-04 1 15E-03 AP 04 63622 01/02/02 Fe-59 -5.96E-03 2. 56E-03 1. 35E-02 AP 04 63622 01/02/02 1-131 1.41E-02 1.56E-02 5 47E-02 AP 04 63622 01/02/02 K-40 -4.40E-04 4 01E-03 1. 72E-02 AP 04 63622 01/02/02 Mn-54 -6.71E-04 5. 01E-04 2. 13E-03 AP 04 63622 01/02/02 Ru-103 5.60E-04 7. 23E-04 2. 63E-03 AP 04 63622 01/02/02 Ru-106 3.80E-03 3. 31E-03 1. 14E-02 AP 04 63622 01/02/02 Sb-124 -7.60E-05 1. 13E-03 5. 86E-03 AP 04 63622 01/02/02 Se-75 4.12E-04 4. 66E-04 1 . 62E-03 AP 04 63622 01/02/02 Zn-65 -4.63E-03 1. 26E-03 6. 31E-03 AP 04 63622 01/02/02 Zr-95 0.00E+00 1. 19E-03 4. 71E-03
- Concentration Greater than 3 Standard Deviations 22
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 05 59651 03/28/01 Th-232 -3. 82E-04 1. 31E-03 5. 55E-03 AP 05 59651 03/28/01 Ag-IIOM -9. 23E-05 4.55E-04 2. 06E-03 AP 05 59651 03/28/01 Ba-140 -1. 56E-02 2. 23E-02 0. 11E+00 AP 05 59651 03/28/01 Be-7 0. 12E+00 1. 48E-02 1.99E-02 AP 05 59651 03/28/01 Ce-141 -5. 57E-04 1. 55E-03 5. 94E-03 AP 05 59651 03/28/01 Ce-144 7.25E-04 1. 30E-03 4. 67E-03 AP 05 59651 03/28/01 Co-57 -8. 0OE-05 1. 45E-04 5.77E-04 AP 05 59651 03/28/01 Co-58 -3. 70E-04 4. 13E-04 2.28E-03 AP 05 59651 03/28/01 Co-60 7.81E-04 4. 32E-04 1.25E-03 AP 05 59651 03/28/01 Cr-51 -6. 34E-03 1. 62E-02 6. 38E-02 AP 05 59651 03/28/01 Cs-134 5. 1OE-04 3. 30E-04 1. 04E-03 AP 05 59651 03/28/01 Cs-137 1.40E-04 2. 81E-04 1. 10E-03 AP 05 59651 03/28/01 Fe-59 -1. 48E-03 1.48E-03 1. 03E-02 AP 05 59651 03/28/01 1-131 4. 30E-02 0. 11E+00 0.41E+00 AP 05 59651 03/28/01 K-40 -1. 42E-03 3. 39E-03 1. 65E-02 AP 05 59651 03/28/01 Mn-54 0. OOE+00 4.37E-04 1.7 6E-03 AP 05 59651 03/28/01 Ru-103 -6. 01E-04 1. 20E-03 5. 01E-03 AP 05 59651 03/28/01 Ru-106 4.32E-03 3. 60E-03 1.24E-02 AP 05 59651 03/28/01 Sb-124 -1. 08E-03 1. 88E-03 1. 01E-02 AP 05 59651 03/28/01 Se-75 2.78E-04 5. 79E-04 2.08E-03 AP 05 59651 03/28/01 Zn-65 9. 96E-04 9. 96E-04 3. 58E-03 AP 05 59651 03/28/01 Zr-95 1.04E-03 1.26E-03 4. 65E-03 AP 05 61245 06/27/01 Th-232 3. 58E-04 1.41E-03 5. 63E-03 AP 05 61245 06/27/01 Ag-IlOM 4.26E-04 6. 74E-04 2. 56E-03 AP 05 61245 06/27/01 Ba-140 0.OOE+00 4.51E-02 0 . 20E+00 AP 05 61245 06/27/01 Be-7 0. 17E+00 1. 99E-02 2.82E-02
- AP 05 61245 06/27/01 Ce-141 4.74E-04 1.70E-03 6. 29E-03 AP 05 61245 06/27/01 Ce-144 -8.58E-04 1.21E-03 4. 89E-03 AP 05 61245 06/27/01 Co-57 -3. 85E-05 1. 86E-04 6. 99E-04 AP 05 61245 06/27/01 Co-58 9. 01E-04 7.09E-04 2. 40E-03 AP 05 61245 06/27/01 Co-60 -2 . 33E-04 3. 51E-04 1. 85E-03 AP 05 61245 06/27/01 Cr-51 -2 48E-02 2. 11E-02 8 80E-02 AP 05 61245 06/27/01 Cs-134 -3. 21E-04 3.27E-04 1 . 64E-03 AP 05 61245 06/27/01 Cs-137 -6. 86E-05 3.16E-04 1. 36E-03 AP 05 61245 06/27/01 Fe-59 3. 06E-03 4.46E-03 1.73E-02 AP 05 61245 06/27/01 1-131 -9. 66E-02 0. 18E+00 0. 77E+00 AP 05 61245 06/27/01 K-40 9. 57E-03 6.48E-03 2. 12E-02 AP 05 61245 06/27/01 Mn-54 5. 52E-04 5.16E-04 1. 81E-03 AP 05 61245 06/27/01 Ru-103 -3 .79E-04 1.47E-03 6.01E-03 AP 05 61245 06/27/01 Ru-106 3. 85E-03 2. 53E-03 7 . 96E-03 AP 05 61245 06/27/01 Sb-124 0. OOE+00 2. OOE-03 1 . 04E-02 AP 05 61245 06/27/01 Se-75 -3. 02E-04 5. 96E-04 2 32E-03 AP 05 61245 06/27/01 Zn-65 -2 . 34E-03 1. 35E-03 6.50E-03 AP 05 61245 06/27/01 Zr-95 -1. 15E-03 1. 41E-03 6. 66E-03
- Concentration Greater than 3 Standard Deviations 23
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 05 62427 09/26/01 Th-232 2.34E-04 1.34E-03 5.37E-03 AP 05 62427 09/26/01 Ag-lIOM 5.68E-04 3.97E-04 1.26E-03 AP 05 62427 09/26/01 Ba-140 -1. 34E-02 1.06E-02 5.81E-02 AP 05 62427 09/26/01 Be-7 0. 14E+00 1. 63E-02 2 .89E-02
- AP 05 62427 09/26/01 Ce-141 1. 07E-03 1.35E-03 4 .70E-03 AP 05 62427 09/26/01 Ce-144 -2. 00E-03 1.56E-03 6. 21E-03 AP 05 62427 09/26/01 Co-57 5. 58E-05 1. 73E-04 6. 31E-04 AP 05 62427 09/26/01 Co-58 3. 09E-04 5. 84E-04 2. 29E-03 AP O5 62427 09/26/01 Co-60 -4. 06E-04 4.32E-04 2. 09E-03 AP O5 62427 09/26/01 Cr-51 2. 14E-02 1.24E-02 3. 97E-02 AP 05 62427 09/26/01 Cs-134 -7. 56E-05 2. 51E-04 1. 21E-03 AP 05 62427 09/26/01 Cs-137 7. 91E-05 4.09E-04 1. 57E-03 AP O5 62427 09/26/01 Fe-59 -1 . 39E-04 1. 67E-03 8. 65E-03 AP 05 62427 09/26/01 1-131 0. OOE+00 3. 60E-02 0. 14E+00 AP 05 62427 09/26/01 K-40 -6. 17E-03 5.21E-03 2. 44E-02 AP 05 62427 09/26/01 Mn-54 -4. 63E-04 3. 95E-04 1. 84E-03 AP 05 62427 09/26/01 Ru-103 4. 94E-04 6. 99E-04 2. 66E-03 AP O5 62427 09/26/01 Ru-106 2.09E-03 3. 16E-03 1. 18E-02 AP 05 62427 09/26/01 Sb-124 -9. 59E-04 9. 59E-04 7. 06E-03 AP 05 62427 09/26/01 Se-75 0. 00E+00 5. 13E-04 1. 93E-03 AP 05 62427 09/26/01 Zn-65 -1. 31E-03 1. 03E-03 4 .91E-03 AP 05 62427 09/26/01 Zr-95 -5. 59E-04 8. 39E-04 4. 15E-03 AP 05 63623 01/02/02 Th-232 -1. 65E-03 1.20E-03 5. 82E-03 AP 05 63623 01/02/02 Ag-lIOM 3. 55E-04 S. 02E-04 1. 91E-03 AP 05 63623 01/02/02 Ba-140 0. OOE+00 8. 14E-03 3. 58E-02 AP 05 63623 01/02/02 Be-7 9. 17E-02 1. 17E-02 1.76E-02
- AP 05 63623 01/02/02 Ce-141 5. 35E-04 1. 08E-03 3. 83E-03 AP 05 63623 01/02/02 Ce-144 2 . 95E-04 1.29E-03 4. 69E-03 AP 05 63623 01/02/02 Co-57 -7. 66E-05 1. 37E-04 5. 37E-04 AP 05 63623 01/02/02 Co-58 -9. 98E-04 4. 07E-04 2. 48E-03 AP 05 63623 01/02/02 Co-60 -2. 08E-04 3. 12E-04 1. 65E-03 AP 05 63623 01/02/02 Cr-51 2. 00E-02 9.77E-03 3. 03E-02 AP 05 63623 01/02/02 Cs-134 1.48E-04 2. 52E-04 1. 03E-03 AP 05 63623 01/02/02 Cs-137 4. 62E-05 2.63E-04 1. 09E-03 AP 05 63623 01/02/02 Fe-59 1. 02E-03 1.02E-03 2. 75E-03 AP 05 63623 01/02/02 1-131 3. 22E-02 1.37E-02 3. 87E-02 AP 05 63623 01/02/02 K-40 7.27E-03 5.4 9E-03 1. 85E-02 AP 05 63623 01/02/02 Mn-54 -1. 17E-04 3.50E-04 1. 53E-03 AP 05 63623 01/02/02 Ru-103 4 . 14E-04 5. 86E-04 2. 23E-03 AP 05 63623 01/02/02 Ru-106 5. 7 1E-03 2. 93E-03 8. 66E-03 AP 05 63623 01/02/02 Sb-124 -1. 85E-03 1.31E-03 8. 58E-03 AP 05 63623 01/02/02 Se-75 -3.86E-04 4.16E-04 1. 69E-03 AP 05 63623 01/02/02 Zn-65 6. 49E-04 9. 18E-04 3.4 9E-03 AP 05 63623 01/02/02 Zr-95 -9. 77E-04 1. 17E-03 S. 22E-03
- Concentration Greater than 3 Standard Deviations 24
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 06 59652 03/28/01 Th-232 -9. 32E-05 1.06E-03 4. 68E-03 AP 06 59652 03/28/01 Ag-IlOM -4 . 01E-04 5. 67E-04 2. 63E-03 AP 06 59652 03/28/01 Be-7 5. 71E-02 1.33E-02 3.38E-02
- AP 06 59652 03/28/01 Ce-141 1.06E-03 1.46E-03 5. 15E-03 AP 06 59652 03/28/01 Ce-144 1. 47E-04 1. 11E-03 4.19E-03 AP 06 59652 03/28/01 Co-57 -2. 36E-04 1.73E-04 6. 99E-04 AP 06 59652 03/28/01 Co-58 -3. 99E-04 4.46E-04 2. 46E-03 AP 06 59652 03/28/01 Co-60 -4. 26E-04 3. 93E-04 2.07E-03 AP 06 59652 03/28/01 Cr-51 3. 20E-03 1. 60E-02 6.03E-02 AP 06 59652 03/28/01 Cs-134 4. 85E-05 2. 98E-04 1.29E-03 AP 06 59652 03/28/01 Cs-137 1. 65E-05 3. 55E-04 1.43E-03 AP 06 59652 03/28/01 Fe-59 -1. 84E-04 2.21E-03 1. 15E-02 AP 06 59652 03/28/01 1-131 8. 80E-02 6. 96E-02 0. 24E+00 AP 06 59652 03/28/01 K-40 -3. 04E-03 4.09E-03 2. 03E-02 AP 06 59652 03/28/01 Mn-54 2. 61E-04 3. 20E-04 1.21E-03 AP 06 59652 03/28/01 Ru-103 6. 26E-04 1. 09E-03 4. 11E-03 AP 06 59652 03/28/01 Ru-106 2. 70E-03 2. 20E-03 7. 55E-03 AP 06 59652 03/28/01 Se-75 9. 24E-05 4.23E-04 1. 61E-03 AP 06 59652 03/28/01 Zn-65 1. 1OE-03 9. 71E-04 3. 41E-03 AP 06 59652 03/28/01 Zr-95 2. 75E-03 1. 25E-03 3. 1OE-03 AP 06 61246 06/27 /01 Th-232 2. 80E-04 1. 31E-03 5. 34E-03 AP 06 61246 06/27 /01 Ag-IIOM 4 .19E-04 5. 13E-04 1. 95E-03 AP 06 61246 06/27 /01 Ba-140 1.77E-02 1.77E-02 4 .80E-02 AP 06 61246 06/27 /01 Be-7 0. 12E+00 1. 86E-02 3.76E-02
- AP 06 61246 06/27 /01 Ce-141 -2. 09E-04 1. 95E-03 7. 33E-03 AP 06 61246 06/27 /01 Ce-144 -5. 91E-04 1.29E-03 5. 05E-03 AP 06 61246 06/27 /01 Co-57 -1. 50E-04 1. 59E-04 6. 45E-04 AP 06 61246 06/27 /01 Co-58 -6. 50E-04 6. 61E-04 3. 32E-03 AP 06 61246 06/27 /01 Co-60 3. 62E-04 2.56E-04 4. 90E-04 AP 06 61246 06/27 /01 Cr-51 1 .68E-02 1. 87E-02 6. 64E-02 AP 06 61246 06/27 /01 Cs-134 5. 01E-05 3. 07E-04 1. 34E-03 AP 06 61246 06/27 /01 Cs-137 -5. 28E-04 3. 62E-04 1. 69E-03 AP 06 61246 06/27 /01 Fe-59 -2. 12E-03 3. 19E-03 1. 68E-02 AP 06 61246 06/27 /01 1-131 -0. 54E+00 0. 24E+00 1. 09E+00 AP 06 61246 06/27 /01 K-40 -3. 34E-03 3. 68E-03 1. 94E-02 AP 06 61246 06/27 /01 Mn-54 6. 80E-04 4. 08E-04 1.26E-03 AP 06 61246 06/27 /01 Ru-103 0. OOE+00 1. 07E-03 4. 56E-03 AP 06 61246 06/27 /01 Ru-106 1. 17E-03 3. 71E-03 1. 44E-02 AP 06 61246 06/27 /01 Sb-124 -1.36E-03 1. 36E-03 1. 00E-02 AP 06 61246 06/27 /01 Se-75 1. 64E-03 5. 98E-04 1. 71E-03 AP 06 61246 06/27 /01 Zn-65 3. 81E-04 1. 01E-03 4 . 1OE-03 AP 06 61246 06/27 /01 Zr-95 -1. 07E-03 1. 55E-03 7 . OOE-03
- Concentration Greater than 3 Standard Deviations 25
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 06 62428 09/26/01 Th-232 -1. 34E-03 1. 06E-03 5.41E-03 AP 06 62428 09/26/01 Ag-IIOM 0 OOE+00 4.74E-04 2.08E-03 AP 06 62428 09/26/01 Ba-140 -5. 73E-03 5. 73E-03 4.21E-02 AP 06 62428 09/26/01 Be-7 8. 77E-02 1.29E-02 2.36E-02
- AP 06 62428 09/26/01 Ce-141 1. 66E-03 1. 04E-03 3.40E-03 AP 06 62428 09/26/01 Ce-144 1. 93E-03 1. 12E-03 3. 60E-03 AP 06 62428 09/26/01 Co-57 -2. 81E-04 1. 42E-04 6. 17E-04 AP 06 62428 09/26/01 Co-58 -1.36E-04 4. 51E-04 2. 18E-03 AP 06 62428 09/26/01 Co-60 -8. 02E-04 4 . 01E-04 2. 30E-03 AP 06 62428 09/26/01 Cr-51 -9. 43E-03 1. 11E-02 4. 59E-02 AP 06 62428 09/26/01 Cs-134 1. 60E-05 1. 70E-04 8.83E-04 AP 06 62428 09/26/01 Cs-137 -4. 94E-05 2. 63E-04 1. 16E-03 AP 06 62428 09/26/01 Fe-59 -4. 56E-04 3. 17E-03 1. 40E-02 AP 06 62428 09/26/01 1-131 0. OOE+00 2.67E-02 0. 11E+00 AP 06 62428 09/26/01 K-40 2.86E-04 3. 20E-03 1. 51E-02 AP 06 62428 09/26/01 Mn-54 0. OOE+00 3. 58E-04 1. 52E-03 AP 06 62428 09/26/01 Ru-103 -7. 57E-04 7. 57E-04 3.56E-03 AP 06 62428 09/26/01 Ru-106 -4. 64E-04 2.47E-03 1.09E-02 AP 06 62428 09/26/01 Sb-124 -1. 07E-03 1. 07E-03 7.89E-03 AP 06 62428 09/26/01 Se-75 8. 59E-05 5. 08E-04 1.88E-03 AP 06 62428 09/26/01 Zn-65 -1. 06E-03 1. 28E-03 5. 61E-03 AP 06 62428 09/26/01 Zr-95 -8. 82E-04 1. 08E-03 5. 11E-03 AP 06 63624 01/02/02 Th-232 -5. 39E-04 1.34E-03 5. 7 6E-03 AP 06 63624 01/02/02 Ag-IIOM -5. 41E-04 5. 98E-04 2. 71E-03 AP 06 63624 01/02/02 Ba-140 0. OOE+00 6. 63E-03 3. 08E-02 AP 06 63624 01/02/02 Be-7 5. 32E-02 1. 02E-02 2.25E-02
- AP 06 63624 01/02/02 Ce-141 -4 .76E-04 9. 20E-04 3. 59E-03 AP 06 63624 01/02/02 Ce-144 -2.40E-04 1. 02E-03 4 . OOE-03 AP 06 63624 01/02/02 Co-57 4.19E-06 1. 36E-04 5.13E-04 AP 06 63624 01/02/02 Co-58 -9. 68E-05 4.77E-04 2. 16E-03 AP 06 63624 01/02/02 Co-60 -7. 49E-04 3. 74E-04 2. 14E-03 AP 06 63624 01/02/02 Cr-51 5. 71E-03 9. 13E-03 3. 32E-02 AP 06 63624 01/02/02 Cs-134 3. 78E-04 2. 64E-04 8. 36E-04 AP 06 63624 01/02/02 Cs-137 -2. 68E-04 2.97E-04 1. 36E-03 AP 06 63624 01/02/02 Fe-59 1. 02E-03 1. 02E-03 2.76E-03 AP 06 63624 01/02/02 1-131 1. 01E-02 1.01E-02 3. 64E-02 AP 06 63624 01/02/02 K-40 2. 33E-04 4 .15E-03 1. 80E-02 AP 06 63624 01/02/02 Mn-54 0. OOE+00 3. 76E-04 1.56E-03 AP 06 63624 01/02/02 Ru-103 -2. 15E-04 8.84E-04 3. 57E-03 AP 06 63624 01/02/02 Ru-106 -4. 26E-03 2.46E-03 1. 27E-02 AP 06 63624 01/02/02 Sb-124 0. OOE+00 1. 30E-03 6.76E-03 AP 06 63624 01/02/02 Se-75 0. OOE+00 3.45E-04 1. 35E-03 AP 06 63624 01/02/02 Zn-65 -9. 81E-04 7. 31E-04 3. 93E-03 AP 06 63624 01/02/02 Zr-95 1.74E-04 9.22E-04 3. 86E-03
- Concentration Greater than 3 Standard Deviations 26
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 07 59653 03/28/01 Th-232 -1.25E-04 1. 30E-03 5.50E-03 AP 07 59653 03/28/01 Ag-IIOM 0. OOE+00 5.74E-04 2.44E-03 AP 07 59653 03/28/01 Ba-140 -2. 19E-02 2. 19E-02 0. 12E+00 AP 07 59653 03/28/01 Be-7 7 .19E-02 1. 56E-02 3. 97E-02
- AP 07 59653 03/28/01 Ce-141 -1. 08E-03 1. 35E-03 5. 46E-03 AP 07 59653 03/28/01 Ce-144 1. 42E-03 1. 36E-03 4. 69E-03 AP 07 59653 03/28/01 Co-57 5. 16E-05 1.48E-04 5. 48E-04 AP 07 59653 03/28/01 Co-58 -1. 56E-04 5.16E-04 2 .49E-03 AP 07 59653 03/28/01 Co-60 1. 12E-04 5.00E-04 2 . 06E-03 AP 07 59653 03/28/01 Cr-51 -1. 34E-02 1.49E-02 6. 28E-02 AP 07 59653 03/28/01 Cs-134 6. 73E-04 3. 42E-04 9. 09E-04 AP 07 59653 03/28/01 Cs-137 -1. 18E-04 4. 12E-04 1. 68E-03 AP 07 59653 03/28/01 Fe-59 4 40E-03 2.54E-03 3. 97E-03 AP 07 59653 03/28/01 1-131 -4. 55E-02 9.66E-02 0. 40E+00 AP 07 59653 03/28/01 K-40 2. 97E-03 5. 11E-03 1. 98E-02 AP 07 59653 03/28/01 Mn-54 0. OOE+00 3.24E-04 1. 42E-03 AP 07 59653 03/28/01 Ru-103 3. 23E-04 1.07E-03 4. 23E-03 AP 07 59653 03/28/01 Ru-106 6. 4 9E-04 2.33E-03 9.84E-03 AP 07 59653 03/28/01 Sb-124 -2. 44E-03 2 .44E-03 1. 32E-02 AP 07 59653 03/28/01 Se-75 0. 00E+00 5. 12E-04 1. 95E-03 AP 07 59653 03/28/01 Zn-65 3. 68E-04 9.75E-04 3. 97E-03 AP 07 59653 03/28/01 Zr-95 -5 .70E-04 1. 34E-03 5. 94E-03 AP 07 61247 06/27/01 Th-232 -5.44E-04 1. 19E-03 5.25E-03 AP 07 61247 06/27/01 Ag-lIOM -2.36E-04 5. 52E-04 2.45E-03 AP 07 61247 06/27/01 Ba-140 -1.25E-02 2. 53E-02 0. 14E+00 AP 07 61247 06/27/01 Be-7 9. 86E-02 1.70E-02 3.81E-02
- AP 07 61247 06/27/01 Ce-141 5.26E-03 2. 08E-03 6. 26E-03 AP 07 61247 06/27/01 Ce-144 2.06E-03 1. 54E-03 5. 17E-03 AP 07 61247 06/27/01 Co-57 3.21E-04 1. 82E-04 5 .88E-04 AP 07 61247 06/27/01 Co-58 6. 17E-04 7 43E-04 2 .75E-03 AP 07 61247 06/27/01 Co-60 -4.20E-04 4. 89E-04 2 .25E-03 AP 07 61247 06/27/01 Cr-51 -1. 18E-02 2. 04E-02 8. 15E-02 AP 07 61247 06/27/01 Cs-134 1.81E-04 3.42E-04 1 .34E-03 AP 07 61247 06/27/01 Cs-137 -4. 65E-04 2.96E-04 1 .44E-03 AP 07 61247 06/27/01 Fe-59 6. 01E-03 3. 00E-03 4. 06E-03 AP 07 61247 06/27/01 1-131 0. 18E+00 0. 19E+00 0. 69E+00 AP 07 61247 06/27/01 K-40 -5. 44E-03 3. 00E-03 1.81E-02 AP 07 61247 06/27/01 Mn-54 9. 19E-05 3. 99E-04 1. 60E-03 AP 07 61247 06/27/01 Ru-103 -6. 99E-04 1.21E-03 5.25E-03 AP 07 61247 06/27/01 Ru-106 3. 79E-03 3. 73E-03 1. 31E-02 AP 07 61247 06/27/01 Sb-124 2. 39E-03 1. 69E-03 3.23E-03 AP 07 61247 06/27/01 Se-75 -6. 80E-04 5. 05E-04 2. 13E-03 AP 07 61247 06/27/01 Zn-65 -1. 36E-03 1. 18E-03 5.38E-03 AP 07 61247 06/27/01 Zr-95 -2.06E-03 1. 78E-03 7. 91E-03
- Concentration Greater than 3 Standard Deviations 27
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 07 62429 09/26/01 Th-232 -9.83E-04 1.34E-03 6.03E-03 AP 07 62429 09/26/01 Ag-lIOM -7.69E-04 5.44E-04 2.71E-03 AP 07 62429 09/26/01 Ba-140 -1.l1E-02 7.87E-03 5.17E-02 AP 07 62429 09/26/01 Be-7 9.38E-02 1.30E-02 2.10E-02
- AP 07 62429 09/26/01 Ce-141 -3.25E-05 1.15E-03 4.33E-03 AP 07 62429 09/26/01 Ce-144 1.82E-03 1.19E-03 3.91E-03 AP 07 62429 09/26/01 Co-57 -1.87E-04 1.46E-04 6.05E-04 AP 07 62429 09/26/01 Co-58 7.59E-04 6.88E-04 2.41E-03 AP 07 62429 09/26/01 Co-60 3.28E-04 3.61E-04 1.36E-03 AP 07 62429 09/26/01 Cr-51 -1.45E-02 1.23E-02 5.15E-02 AP 07 62429 09/26/01 Cs-134 -3.02E-04 3.07E-04 1.54E-03 AP 07 62429 09/26/01 Cs-137 -2.65E-04 2.71E-04 1.31E-03 AP 07 62429 09/26/01 Fe-59 -4.17E-03 2.93E-03 1.54E-02 AP 07 62429 09/26/01 1-131 7.83E-03 3.41E-02 0.13E+00 AP 07 62429 09/26/01 K-40 5.48E-03 3.98E-03 1.30E-02 AP 07 62429 09/26/01 Mn-54 -6.31E-04 2.82E-04 1.65E-03 AP 07 62429 09/26/01 Ru-103 2.55E-04 9.21E-04 3.60E-03 AP 07 62429 09/26/01 Ru-106 -6.22E-04 2.87E-03 1.23E-02 AP 07 62429 09/26/01 Se-75 -3.54E-04 4.15E-04 1.72E-03 AP 07 62429 09/26/01 Zn-65 -1.74E-03 1.05E-03 5.24E-03 AP 07 62429 09/26/01 Zr-95 -1.47E-04 1.10E-03 4.75E-03 AP 07 63625 01/02/02 Th-232 1.10E-03 1.25E-03 4.50E-03 AP 07 63625 01/02/02 Ag-IlOM 2.71E-04 3.95E-04 1.53E-03 AP 07 63625 01/02/02 Ba-140 1.11E-02 5.55E-03 7.50E-03 AP 07 63625 01/02/02 Be-7 4.50E-02 1.10E-02 3.05E-02
- AP 07 63625 01/02/02 Ce-141 6.41E-04 1.41E-03 4.91E-03 AP 07 63625 01/02/02 Ce-144 -2.57E-04 1.55E-03 5.67E-03 AP 07 63625 01/02/02 Co-57 -2.38E-05 2.06E-04 7.45E-04 AP 07 63625 01/02/02 Co-58 3.33E-04 5.27E-04 2.OOE-03 AP 07 63625 01/02/02 Co-60 1.40E-04 3.14E-04 1.30E-03 AP 07 63625 01/02/02 Cr-51 -7.09E-03 1.13E-02 4.34E-02 AP 07 63625 01/02/02 Cs-134 -2.08E-04 3.29E-04 1.47E-03 AP 07 63625 01/02/02 Cs-137 0.00E+00 3.07E-04 1.23E-03 AP 07 63625 01/02/02 Fe-59 -2.58E-03 1.92E-03 1.03E-02 AP 07 63625 01/02/02 1-131 -6.36E-03 1.42E-02 5.70E-02 AP 07 63625 01/02/02 K-40 7.95E-03 4.91E-03 1.57E-02 AP 07 63625 01/02/02 Mn-54 -8.93E-05 4.07E-04 1.65E-03 AP 07 63625 01/02/02 Ru-103 5.65E-04 9.78E-04 3.54E-03 AP 07 63625 01/02/02 Ru-106 -2.30E-03 3.16E-03 1.33E-02 AP 07 63625 01/02/02 Sb-124 2.30E-03 1.33E-03 2.08E-03 AP 07 63625 01/02/02 Se-75 -8.06E-04 5.17E-04 2.08E-03 AP 07 63625 01/02/02 Zn-65 -2.83E-03 1.26E-03 5.82E-03 AP 07 63625 01/02/02 Zr-95 5.99E-04 9.47E-04 3.60E-03
- Concentration Greater than 3 Standard Deviations 28
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 08 59654 03/28/01 Th-232 3. 95E-04 1. 19E-03 4 .76E-03 AP 08 59654 03/28/01 Ag-11OM -3. 93E-04 5. 66E-04 2. 56E-03 AP 08 59654 03/28/01 Ba-140 -3. 43E-02 2.20E-02 0. 12E+00 AP 08 59654 03/28/01 Be-7 7.44E-02 1. 38E-02 3. 08E-02
- AP 08 59654 03/28/01 Ce-141 -7.29E-04 1. 60E-03 6. 16E-03 AP 08 59654 03/28/01 Ce-144 -3. 44E-04 1. 27E-03 4 .89E-03 AP 08 59654 03/28/01 Co-57 4. 24E-05 1. 64E-04 6. 04E-04 AP 08 59654 03/28/01 Co-58 1. 20E-03 6. 66E-04 1. 98E-03 AP 08 59654 03/28/01 Co-60 -4. 01E-04 4. 26E-04 2. 07E-03 AP 08 59654 03/28/01 Cr-51 1. 59E-02 1. 59E-02 5. 54E-02 AP 08 59654 03/28/01 Cs-134 -3. 61E-04 3. 83E-04 1. 7 6E-03 AP 08 59654 03/28/01 Cs-137 -1. 87E-04 3. 39E-04 1. 45E-03 AP 08 59654 03/28/01 Fe-59 1. 15E-03 2. 38E-03 1. 03E-02 AP 08 59654 03/28/01 1-131 6. 49E-02 9. 92E-02 0. 36E+00 AP 08 59654 03/28/01 K-40 1.76E-03 4. 07E-03 1. 65E-02 AP 08 59654 03/28/01 Mn-54 2. 72E-04 2. 84E-04 1. 05E-03 AP 08 59654 03/28/01 Ru-103 1.21E-03 1. 13E-03 3. 95E-03 AP 08 59654 03/28/01 Ru-106 4. 62E-03 3. 03E-03 9.80E-03 AP 08 59654 03/28/01 Sb-124 3.26E-03 1.88E-03 2. 94E-03 AP 08 59654 03/28/01 Se-75 -5. 57E-04 5.4 1E-04 2. 18E-03 AP 08 59654 03/28/01 Zn-65 -9. 98E-04 8. 80E-04 4.36E-03 AP 08 59654 03/28/01 Zr-95 -5. 75E-04 1.09E-03 5 . 07E-03 AP 08 61248 06/27/01 Th-232 -1. 34E-03 1. 22E-03 5.85E-03 AP 08 61248 06/27/01 Ag-liIM 8. 22E-04 7.12E-04 2.47E-03 AP 08 61248 06/27/01 Ba-140 -1.78E-02 1.78E-02 0. 13E+00 AP 08 61248 06/27/01 Be-7 8.70E-02 1. 61E-02 3.62E-02
- AP 08 61248 06/27/01 Ce-141 -2. 57E-03 1.57E-03 6. 72E-03 AP 08 61248 06/27/01 Ce-144 -9. 03E-04 1.29E-03 5. 11E-03 AP 08 61248 06/27/01 Co-57 6. 03E-05 1 . 55E-04 5. 68E-04 AP 08 61248 06/27/01 Co-58 -3. 68E-04 6. 99E-04 3.24E-03 AP 08 61248 06/27/01 Co-60 1. 57E-04 3.25E-04 1. 40E-03 AP 08 61248 06/27/01 Cr-51 -7. 97E-03 1. 87E-02 7.50E-02 AP 08 61248 06/27/01 Cs-134 4.89E-05 3. 00E-04 1. 30E-03 AP 08 61248 06/27/01 Cs-137 4. 96E-05 2.82E-04 1. 17E-03 AP 08 61248 06/27/01 Fe-59 -2. 11E-03 3. 17E-03 1. 67E-02 AP 08 61248 06/27/01 1-131 -9. 34E-02 0. 19E+00 0. 78E+00 AP 08 61248 06/27/01 K-40 2. 86E-04 5. 99E-03 2.44E-02 AP 08 61248 06/27/01 Mn-54 -1. 33E-04 3. 99E-04 1. 74E-03 AP 08 61248 06/27/01 Ru-103 -1. 1OE-03 8. 17E-04 4. 39E-03 AP 08 61248 06/27/01 Ru-106 1.29E-03 3. 27E-03 1.27E-02 AP 08 61248 06/27/01 Sb-124 1. 37E-03 2.37E-03 1. 01E-02 AP 08 61248 06/27/01 Se-75 3. 89E-04 5 . 32E-04 1.8 9E-03 AP 08 61248 06/27/01 Zn-65 -2. 26E-03 1. 19E-03 5. 97E-03 AP 08 61248 06/27/01 Zr-95 1. 66E-03 1.42E-03 4. 93E-03
- Concentration Greater than 3 Standard Deviations 29
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AIR PARTICULATES AP 08 62430 09/26/01 Th-232 -2. 30E-03 1.57E-03 7 .27E-03 AP 08 62430 09/26/01 Ag-IlOM -3. 95E-04 5. 59E-04 2. 59E-03 AP 08 62430 09/26/01 Ba-140 -1. 72E-02 1.28E-02 6.88E-02 AP 08 62430 09/26/01 Be-7 0. 11E+00 1.49E-02 2. 85E-02 AP 08 62430 09/26/01 Ce-141 -6. 01E-04 1. 16E-03 4.53E-03 AP 08 62430 09/26/01 Ce-144 7.48E-04 1. 31E-03 4. 69E-03 AP 08 62430 09/26/01 Co-57 1. 51E-04 1. 68E-04 5. 86E-04 AP 08 62430 09/26/01 Co-58 -2. 78E-04 6.53E-04 2. 90E-03 AP 08 62430 09/26/01 Co-60 1. 7 9E-04 1.79E-04 4. 85E-04 AP 08 62430 09/26/01 Cr-51 -4. 97E-03 9. 93E-03 4. 14E-02 AP 08 62430 09/26/01 Cs-134 -2. 13E-04 2.37E-04 1. 31E-03 AP 08 62430 09/26/01 Cs-137 -4. 25E-04 3.75E-04 1. 69E-03 AP 08 62430 09/26/01 Fe-59 2. 30E-03 2. 53E-03 9.54E-03 AP 08 62430 09/26/01 1-131 -4. 04E-02 3. 13E-02 0. 14E+00 AP 08 62430 09/26/01 K-40 -1. OOE-03 4. 62E-03 2.07E-02 AP 08 62430 09/26/01 Mn-54 -1. 30E-04 3. 89E-04 1. 70E-03 AP 08 62430 09/26/01 Ru-103 -1. 05E-03 7.42E-04 3.70E-03 AP 08 62430 09/26/01 Ru-106 -7. 99E-04 3.29E-03 1.38E-02 AP 08 62430 09/26/01 Sb-124 -1.07E-03 1. 85E-03 9. 94E-03 AP 08 62430 09/26/01 Se-75 -4. 54E-04 5. 22E-04 2.09E-03 AP 08 62430 09/26/01 Zn-65 -2. 15E-03 1. 24E-03 5. 97E-03 AP 08 62430 09/26/01 Zr-95 1.51E-04 9. 26E-04 4. 03E-03 AP 08 63626 01/02/02 Th-232 1. 50E-03 1.32E-03 4. 60E-03 AP 08 63626 01/02/02 Ag-lIOM -1. 77E-04 4. 68E-04 2. 13E-03 AP 08 63626 01/02/02 Ba-140 3.32E-03 3. 32E-03 8. 99E-03 AP 08 63626 01/02/02 Be-7 6. 71E-02 1. 02E-02 1.76E-02 AP 08 63626 01/02/02 Ce-141 1.31E-04 8. 65E-04 3.22E-03 AP 08 63626 01/02/02 Ce-144 -7. 52E-04 1. 15E-03 4.52E-03 AP 08 63626 01/02/02 Co-57 1. 13E-04 1. 49E-04 5.25E-04 AP 08 63626 01/02/02 Co-58 -1. 90E-04 6. 60E-04 2.77E-03 AP 08 63626 01/02/02 Co-60 1 .24E-04 3.89E-04 1. 64E-03 AP 08 63626 01/02/02 Cr-51 -7 .25E-03 8. 10E-03 3. 41E-02 AP 08 63626 01/02/02 Cs-134 -3.84E-04 3. 03E-04 1.54E-03 AP 08 63626 01/02/02 Cs-137 -2. 61E-04 2.88E-04 1. 33E-03 AP 08 63626 01/02/02 Fe-59 -2.28E-03 1. 61E-03 1. OOE-02 AP 08 63626 01/02/02 1-131 -6. 46E-03 9. 13E-03 4.23E-02 AP 08 63626 01/02/02 K-40 -5. 72E-03 4.22E-03 2. 17E-02 AP 08 63626 01/02/02 Mn-54 -4. 65E-04 4.03E-04 1.85E-03 AP 08 63626 01/02/02 Ru-103 2 . 07E-04 6. 85E-04 2. 71E-03 AP 08 63626 01/02/02 Ru-106 -1. 99E-03 3. 61E-03 1.4 9E-02 AP 08 63626 01/02/02 Sb-124 1. 84E-03 1. 30E-03 2.49E-03 AP 08 63626 01/02/02 Se-75 5. 39E-04 3.85E-04 1 .28E-03 AP 08 63626 01/02/02 Zn-65 -9. 71E-04 7 . 23E-04 3.89E-03 AP 08 63626 01/02/02 Zr-95 4. 24E-05 4.50E-04 2. 35E-03
- Concentration Greater than 3 Standard Deviations 30
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 57899 01/03/01 1-131 -1.08E-02 1.14E-02 4.49E-02 CF 02 57900 01/03/01 1-131 -7.59E-03 1.17E-02 4.56E-02 CF 03 57901 01/03/01 1-131 -5.93E-03 1.10E-02 4.33E-02 CF 04 57902 01/03/01 1-131 0.OOE+00 1.12E-02 4.20E-02 CF 05 57903 01/03/01 1-131 -1.77E-03 1.08E-02 4.08E-02 CF 06 57904 01/03/01 1-131 0.OOE+00 1.32E-02 4.85E-02 CF 07 57905 01/03/01 1-131 -1.29E-02 1.06E-02 4.32E-02 CF 08 57906 01/03/01 1-131 1.88E-02 1.22E-02 4.OOE-02 CF 01 57963 01/10/01 1-131 0.OOE+00 8.42E-03 3.07E-02 CF 02 57964 01/10/01 1-131 1.93E-02 9.03E-03 2.84E-02 CF 03 57965 01/10/01 1-131 2.34E-03 7.03E-03 2.56E-02 CF 04 57966 01/10/01 1-131 1.11E-03 7.47E-03 2.73E-02 CF 05 57967 01/10/01 1-131 -3.50E-03 8.50E-03 3.19E-02 CF 06 57968 01/10/01 1-131 7.20E-03 7.96E-03 2.76E-02 CF 07 57969 01/10/01 1-131 2.46E-02 8.54E-03 2.50E-02 CF 08 57970 01/10/01 1-131 1.18E-03 9.03E-03 3.27E-02 CF 01 58104 01/17/01 1-131 -1.71E-03 9.18E-03 3.54E-02 CF 02 58105 01/17/01 1-131 -9.01E-03 1.10E-02 4.33E-02 CF 03 58106 01/17/01 1-131 -3.54E-03 9.70E-03 3.77E-02 CF 04 58107 01/17/01 1-131 -1.72E-02 1.03E-02 4.29E-02 CF 05 58108 01/17/01 1-131 -4.96E-03 9.50E-03 3.71E-02 CF 06 58109 01/17/01 1-131 1.39E-02 9.85E-03 3.28E-02 CF 07 58110 01/16/01 1-131 2.10E-03 1.17E-02 4.35E-02 CF 08 58111 01/17/01 1-131 0.OOE+00 8.35E-03 3.23E-02 CF 01 58178 01/24/01 1-131 -9.47E-03 7.67E-03 3.08E-02 CF 02 58179 01/24/01 1-131 8.74E-03 6.95E-03 2.35E-02 CF 03 58180 01/24/01 1-131 -1.34E-02 7.40E-03 3.10E-02 CF 04 58181 01/24/01 1-131 -5.79E-03 6.66E-03 2.66E-02 CF 05 58182 01/24/01 1-131 -6.94E-03 7.31E-03 2.89E-02 CF 06 58183 01/24/01 1-131 2.46E-03 7.97E-03 2.89E-02 CF 07 58184 01/24/01 1-131 -1.23E-02 6.61E-03 2.80E-02 CF 08 58185 01/24/01 1-131 1.48E-02 7.40E-03 2.32E-02 CF 01 58326 01/31/01 1-131 0.OOE+00 9.74E-03 3.61E-02 CF 02 58327 01/31/01 1-131 -1.33E-02 9.37E-03 3.90E-02 CF 03 58328 01/31/01 1-131 -1.60E-02 1.01E-02 4.16E-02 CF 04 58329 01/31/01 1-131 -6.17E-03 9.25E-03 3.62E-02 CF 05 58330 01/31/01 1-131 0.OOE+00 9.57E-03 3.56E-02 CF 06 58331 01/31/01 1-131 -3.12E-03 1.01E-02 3.83E-02 CF 07 58332 01/31/01 1-131 -6.18E-03 8.74E-03 3.47E-02 CF 08 58333 01/31/01 1-131 1.10E-02 9.55E-03 3.25E-02
- Concentration Greater than 3 Standard Deviations 31
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 58472 02/07/01 1-131 -1.78E-03 1.l1E-02 4.19E-02 CF 02 58473 02/07/01 1-131 1.02E-02 1.14E-02 3.98E-02 CF 03 58474 02/07/01 1-131 1.12E-02 1.09E-02 3.76E-02 CF 04 58475 02/07/01 1-131 -1.86E-03 9.99E-03 3.85E-02 CF 05 58476 02/07/01 1-131 -1.05E-02 1.08E-02 4.31E-02 CF 06 58477 02/07/01 1-131 1.29E-02 1.03E-02 3.47E-02 CF 07 58478 02/07/01 1-131 1.64E-02 1.01E-02 3.30E-02 CF 08 58479 02/07/01 1-131 1.86E-03 1.19E-02 4.37E-02 CF 01 58577 02/14/01 1-131 1.53E-03 8.22E-03 3.07E-02 CF 02 58578 02/14/01 1-131 -3.15E-03 9.70E-03 3.70E-02 CF 03 58579 02/14/01 1-131 -4.76E-03 1.07E-02 4.05E-02 CF 04 58580 02/14/01 1-131 0.OOE+00 9.97E-03 3.69E-02 CF 05 58581 02/14/01 1-131 -6.11E-03 8.08E-03 3.26E-02 CF 06 58582 02/14/01 1-131 -6.33E-03 1.05E-02 4.04E-02 CF 07 58583 02/14/01 1-131 -2.10E-02 1.13E-02 4.62E-02 CF 08 58584 02/14/01 1-131 4.98E-03 1.16E-02 4.15E-02 CF 01 58657 02/21/01 1-131 -3.30E-03 8.73E-03 3.42E-02 CF 02 58658 02/21/01 1-131 -1.71E-03 1.01E-02 3.83E-02 CF 03 58659 02/21/01 1-131 -1.78E-03 9.26E-03 3.58E-02 CF 04 58660 02/21/01 1-131 -1.64E-09 9.09E-03 3.46E-02 CF 05 58661 02/21/01 1-131 3.36E-03 1.04E-02 3.77E-02 CF 06 58662 02/21/01 1-131 1.37E-02 1.08E-02 3.65E-02 CF 07 58663 02/21/01 1-131 1.50E-02 8.96E-03 2.90E-02 CF 08 58664 02/21/01 1-131 1.72E-02 9.44E-03 3.00E-02 CF 01 58756 02/28/01 1-131 0.00E+00 9.43E-03 3.51E-02 CF 02 58757 02/28/01 1-131 -1.07E-02 8.77E-03 3.59E-02 CF 03 58758 02/28/01 1-131 -7.86E-03 1.06E-02 4.09E-02 CF 04 58759 02/28/01 1-131 3.03E-03 9.10E-03 3.32E-02 CF 05 58760 02/28/01 1-131 6.08E-03 9.37E-03 3.33E-02 CF 06 58761 02/28/01 1-131 6.07E-03 9.10E-03 3.23E-02 CF 07 58762 02/28/01 1-131 6.19E-03 9.79E-03 3.47E-02 CF 08 58763 02/28/01 1-131 3.10E-03 1.05E-02 3.80E-02 CF 01 58869 03/07/01 1-131 1.85E-02 1.21E-02 3.96E-02 CF 02 58870 03/07/01 1-131 -2.73E-03 1.25E-02 4.96E-02 CF 03 58871 03/07/01 1-131 1.11E-02 1.30E-02 4.60E-02 CF 04 58872 03/07/01 1-131 1.06E-02 1.40E-02 4.97E-02 CF 05 58873 03/07/01 1-131 2.67E-03 1.16E-02 4.44E-02 CF 06 58874 03/07/01 1-131 -8.27E-03 1.14E-02 4.80E-02 CF 07 58875 03/07/01 1-131 -2.67E-03 1.33E-02 5.20E-02 CF 08 58876 03/07/01 1-131 5.35E-03 1.14E-02 4.24E-02
- Concentration Greater than 3 Standard Deviations 32
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 58979 03/14/01 1-131 -9.17E-03 7.25E-03 3.44E-02 CF 02 58980 03/14/01 1-131 -4.82E-03 9.01E-03 3.82E-02 CF 03 58981 03/14/01 1-131 1.OOE-02 1.37E-02 4.88E-02 CF 04 58982 03/14/01 1-131 2.38E-03 8.56E-03 3.35E-02 CF 05 58983 03/14/01 1-131 -7.11E-03 9.18E-03 3.95E-02 CF 06 58984 03/14/01 1-131 -7.20E-03 1.20E-02 4.82E-02 CF 07 58985 03/14/01 1-131 -2.13E-02 1.09E-02 4.91E-02 CF 08 58986 03/14/01 1-131 1.18E-02 1.18E-02 4.10E-02 CF 01 59079 03/20/01 1-131 -1.29E-02 1.06E-02 4.33E-02 CF 02 59080 03/20/01 1-131 -5.85E-03 9.36E-03 3.80E-02 CF 03 59081 03/21/01 1-131 8.02E-03 8.33E-03 2.91E-02 CF 04 59082 03/21/01 1-131 -9.65E-03 8.81E-03 3.61E-02 CF 05 59083 03/21/01 1-131 1.13E-02 9.27E-03 3.14E-02 CF 06 59084 03/21/01 1-131 0.00E+00 9.65E-03 3.61E-02 CF 07 59085 03/21/01 1-131 6.32E-03 8.37E-03 2.98E-02 CF 08 59086 03/21/01 1-131 4.89E-03 8.77E-03 3.17E-02 CF 01 59154 03/28/01 1-131 -1.83E-02 1.01E-02 4.17E-02 CF 02 59155 03/28/01 1-131 0.OOE+00 7.56E-03 2.89E-02 CF 03 59156 03/28/01 1-131 -6.73E-03 9.51E-03 3.77E-02 CF 04 59157 03/28/01 1-131 0.00E+00 1.15E-02 4.26E-02 CF 05 59158 03/28/01 1-131 2.38E-03 1.37E-02 5.07E-02 CF 06 59159 03/28/01 1-131 6.87E-03 1.06E-02 3.76E-02 CF 07 59160 03/28/01 1-131 -2.21E-02 9.75E-03 4.25E-02 CF 08 59161 03/28/01 1-131 0.00E+00 1.17E-02 4.32E-02 CF 01 59271 04/04/01 1-131 8.96E-03 8.96E-03 3.10E-02 CF 02 59272 04/04/01 1-131 -1.89E-02 7.27E-03 3.34E-02 CF 03 59273 04/04/01 1-131 -7.59E-03 8.45E-03 3.41E-02 CF 04 59274 04/04/01 1-131 -8.OOE-03 7.67E-03 3.22E-02 CF 05 59275 04/04/01 1-131 6.69E-03 1.03E-02 3.66E-02 CF 06 59276 04/04/01 1-131 7.67E-03 8.26E-03 2.89E-02 CF 07 59277 04/04/01 1-131 -4.65E-03 8.90E-03 3.48E-02 CF 08 59278 04/04/01 1-131 -3.11E-03 9.06E-03 3.49E-02 CF 01 59425 04/11/01 1-131 -7.39E-03 1.37E-02 5.40E-02 CF 02 59426 04/11/01 1-131 2.64E-02 1.10E-02 3.15E-02 CF 03 59427 04/11/01 1-131 9.85E-03 1.21E-02 4.29E-02 CF 04 59428 04/11/01 1-131 -1.80E-02 9.93E-03 4.65E-02 CF 05 59429 04/11/01 1-131 -5.28E-03 1.35E-02 5.31E-02 CF 06 59430 04/11/01 1-131 1.55E-02 1.26E-02 4.29E-02 CF 07 59431 04/11/01 1-131 1.26E-02 1.31E-02 4.57E-02 CF 08 59432 04/11/01 1-131 -7.66E-03 1.28E-02 5.13E-02
- Concentration Greater than 3 Standard Deviations 33
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 59511 04/17/01 1-131 -7.85E-03 1.05E-02 4.08E-02 CF 02 59512 04/17/01 1-131 6.22E-03 9.33E-03 3.32E-02 CF 03 59513 04/18/01 1-131 -5.55E-03 9.40E-03 3.60E-02 CF 04 59514 04/18/01 1-131 -1.75E-02 1.01E-02 4.10E-02 CF 05 59515 04/18/01 1-131 2.94E-03 9.75E-03 3.53E-02 CF 06 59516 04/17/01 1-131 0.OOE+00 1.06E-02 3.92E-02 CF 07 59517 04/17/01 1-131 0.OOE+00 1.11E-02 4.10E-02 CF 08 59518 04/17/01 1-131 3.33E-03 1.13E-02 4.09E-02 CF 01 59608 04/25/01 1-131 -2.16E-02 1.04E-02 4.39E-02 CF 02 59609 04/25/01 1-131 1.63E-03 9.38E-03 3.48E-02 CF 03 59610 04/25/01 1-131 9.24E-03 1.06E-02 3.72E-02 CF 04 59611 04/25/01 1-131 2.13E-02 1.04E-02 3.22E-02 CF 05 59612 04/25/01 1-131 0.OOE+00 1.20E-02 4.46E-02 CF 06 59613 04/25/01 1-131 -1.74E-03 1.09E-02 4.09E-02 CF 07 59614 04/25/01 1-131 1.53E-02 1.12E-02 3.73E-02 CF 08 59615 04/25/01 1-131 -8.63E-03 1.02E-02 4.06E-02 CF 01 59784 05/02/01 1-131 1.67E-03 9.88E-03 3.66E-02 CF 02 59785 05/02/01 1-131 1.64E-02 8.35E-03 2.60E-02 CF 03 59786 05/02/01 1-131 -1.71E-03 9.22E-03 3.55E-02 CF 04 59787 05/02/01 1-131 7.23E-03 9.89E-03 3.52E-02 CF 05 59788 05/02/01 1-131 0.OOE+00 8.83E-03 3.39E-02 CF 06 59789 05/02/01 1-131 6.89E-03 1.03E-02 3.67E-02 CF 07 59790 05/02/01 1-131 3.41E-03 1.02E-02 3.73E-02 CF 08 59791 05/02/01 1-131 1.93E-02 1.01E-02 3.18E-02 CF 01 59863 05/09/01 1-131 3.83E-03 1.08E-02 3.97E-02 CF 02 59864 05/09/01 1-131 7.65E-03 1.08E-02 3.85E-02 CF 03 59865 05/09/01 1-131 4.15E-03 1.10E-02 4.04E-02 CF 04 59866 05/09/01 1-131 8.87E-03 1.22E-02 4.32E-02 CF 05 59867 05/09/01 1-131 -6.31E-03 1.13E-02 4.48E-02 CF 06 59868 05/09/01 1-131 6.14E-03 1.02E-02 3.71E-02 CF 07 59869 05/09/01 1-131 -1.66E-02 1.25E-02 5.09E-02 CF 08 59870 05/09/01 1-131 -8.07E-03 1.21E-02 4.74E-02 CF 01 59944 05/16/01 1-131 -1.46E-03 9.32E-03 3.50E-02 CF 02 59945 05/16/01 1-131 1.31E-02 1.04E-02 3.50E-02 CF 03 59946 05/16/01 1-131 -6.13E-03 1.13E-02 4.25E-02 CF 04 59947 05/16/01 1-131 1.56E-02 9.85E-03 3.23E-02 CF 05 59948 05/16/01 1-131 1.28E-02 1.13E-02 3.86E-02 CF 06 59949 05/16/01 1-131 -1.20E-02 1.02E-02 4.04E-02 CF 07 59950 05/16/01 1-131 2.86E-09 1.08E-02 3.96E-02 CF 08 59951 05/16/01 1-131 -7.66E-03 9.81E-03 3.83E-02
- Concentration Greater than 3 Standard Deviations 34
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 60075 05/22/01 1-131 -8.92E-03 1.11E-02 4.38E-02 CF 02 60076 05/23/01 1-131 -1.17E-02 8.99E-03 3.75E-02 CF 03 60077 05/23/01 1-131 1.45E-02 1.14E-02 3.86E-02 CF 04 60078 05/23/01 1-131 0.OOE+00 8.53E-03 3.24E-02 CF 05 60079 05/23/01 1-131 -1.80E-03 1.07E-02 4.04E-02 CF 06 60080 05/23/01 1-131 1.29E-02 9.91E-03 3.34E-02 CF 07 60081 05/23/01 1-131 9.31E-03 1.22E-02 4.28E-02 CF 08 60082 05/23/01 1-131 0.OOE+00 9.31E-03 3.44E-02 CF 01 60224 05/30/01 1-131 2.88E-03 9.10E-03 3.31E-02 CF 02 60225 05/30/01 1-131 1.98E-02 8.46E-03 2.53E-02 CF 03 60226 05/30/01 1-131 -1.63E-03 9.65E-03 3.66E-02 CF 04 60227 05/30/01 1-131 -6.70E-03 1.01E-02 3.94E-02 CF 05 60228 05/30/01 1-131 9.74E-03 8.59E-03 2.94E-02 CF 06 60229 05/30/01 1-131 -1.68E-02 8.86E-03 3.85E-02 CF 07 60230 05/30/01 1-131 -3.23E-03 7.22E-03 2.93E-02 CF 08 60231 05/30/01 1-131 3.37E-03 1.09E-02 3.96E-02 CF 01 60401 06/06/01 1-131 9.78E-03 9.78E-03 3.45E-02 CF 02 60402 06/06/01 1-131 -1.05E-02 1.01E-02 4.24E-02 CF 03 60403 06/06/01 1-131 -2.56E-03 1.28E-02 4.99E-02 CF 04 60404 06/06/01 1-131 2.61E-03 1.25E-02 4.74E-02 CF 05 60405 06/06/01 1-131 -1.53E-02 1.53E-02 6.12E-02 CF 06 60406 06/06/01 1-131 0.OOE+00 1.34E-02 5.11E-02 CF 07 60407 06/06/01 1-131 0.OOE+00 1.07E-02 4.20E-02 CF 08 60408 06/06/01 1-131 7.56E-03 1.21E-02 4.39E-02 CF 01 60492 06/13/01 1-131 -9.81E-03 8.95E-03 3.67E-02 CF 02 60493 06/13/01 1-131 -6.36E-03 8.42E-03 3.39E-02 CF 03 60494 06/13/01 1-131 -1.39E-03 8.23E-03 3.12E-02 CF 04 60495 06/13/01 1-131 1.OOE-02 9.84E-03 3.37E-02 CF 05 60496 06/13/01 1-131 -1.37E-03 8.10E-03 3.07E-02 CF 06 60497 06/13/01 1-131 -1.34E-02 8.48E-03 3.48E-02 CF 07 60498 06/13/01 1-131 3.98E-03 6.89E-03 2.50E-02 CF 08 60499 06/13/01 1-131 -1.36E-03 9.33E-03 3.47E-02 CF 01 60557 06/20/01 1-131 -1.45E-02 8.65E-03 3.55E-02 CF 02 60558 06/20/01 1-131 1.03E-02 7.93E-03 2.67E-02 CF 03 60559 06/20/01 1-131 0.OOE+00 8.89E-03 3.32E-02 CF 04 60560 06/20/01 1-131 1.48E-03 9.93E-03 3.63E-02 CF 05 60561 06/20/01 1-131 -1.44E-03 1.07E-02 3.93E-02 CF 06 60562 06/20/01 1-131 -1.41E-03 7.83E-03 3.OOE-02 CF 07 60563 06/20/01 1-131 4.32E-03 9.22E-03 3.31E-02 CF 08 60564 06/20/01 1-131 -1.38E-03 9.64E-03 3.58E-02
- Concentration Greater than 3 Standard Deviations 35
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 60736 06/27/01 1-131 -3.69E-03 8.15E-03 3.00E-02 CF 02 60737 06/27/01 1-131 -1.26E-02 7.95E-03 3.09E-02 CF 03 60738 06/27/01 1-131 9.98E-04 8.76E-03 3.13E-02 CF 04 60739 06/27/01 1-131 2.36E-02 9.23E-03 2.85E-02 CF 05 60740 06/27/01 1-131 4.02E-03 8.65E-03 3.04E-02 CF 06 60741 06/27/01 1-131 8.61E-03 9.02E-03 3.07E-02 CF 07 60742 06/27/01 1-131 -9.73E-03 9.73E-03 3.62E-02 CF 08 60743 06/27/01 1-131 9.85E-04 8.98E-03 3.20E-02 CF 01 60808 07/03/01 1-131 1.85E-03 1.03E-02 3.83E-02 CF 02 60809 07/03/01 1-131 1.62E-02 8.61E-03 2.70E-02 CF 03 60810 07/03/01 1-131 7.72E-03 1.16E-02 4.11E-02 CF 04 60811 07/03/01 1-131 -1.73E-03 8.99E-03 3.48E-02 CF 05 60812 07/03/01 1-131 -9.28E-03 9.65E-03 3.96E-02 CF 06 60813 07/03/01 1-131 -3.75E-03 9.56E-03 3.77E-02 CF 07 60814 07/03/01 1-131 -7.28E-03 1.03E-02 4.09E-02 CF 08 60815 07/03/01 1-131 -3.89E-03 1.17E-02 4.47E-02 CF 01 60952 07/11/01 1-131 0.OOE+00 1.08E-02 4.02E-02 CF 02 60953 07/11/01 1-131 1.69E-03 8.45E-03 3.18E-02 CF 03 60954 07/11/01 1-131 -1.76E-02 1.22E-02 4.98E-02 CF 04 60955 07/11/01 1-131 2.20E-02 1.22E-02 3.90E-02 CF 05 60956 07/11/01 1-131 -7.47E-03 1.24E-02 4.76E-02 CF 06 60957 07/11/01 1-131 3.68E-03 1.14E-02 4.13E-02 CF 07 60958 07/11/01 1-131 -7.45E-03 1.15E-02 4.47E-02 CF 08 60959 07/11/01 1-131 -3.63E-03 9.95E-03 3.87E-02 CF 01 61043 07/18/01 1-131 -1.29E-03 8.86E-03 3.30E-02 CF 02 61044 07/18/01 1-131 -1.26E-03 8.24E-03 3.08E-02 CF 03 61045 07/18/01 1-131 -1.16E-02 1.10E-02 4.26E-02 CF 04 61046 07/18/01 1-131 -1.37E-03 9.57E-03 3.55E-02 CF 05 61047 07/18/01 1-131 1.78E-02 1.09E-02 3.55E-02 CF 06 61048 07/18/01 1-131 -1.08E-02 9.57E-03 3.76E-02 CF 07 61049 07/18/01 1-131 0.00E+00 9.52E-03 3.49E-02 CF 08 61050 07/18/01 1-131 -8.18E-03 9.64E-03 3.72E-02 CF 01 61188 07/25/01 1-131 1.79E-03 9.61E-03 3.59E-02 CF 02 61189 07/25/01 1-131 6.95E-03 1.13E-02 4.00E-02 CF 03 61190 07/25/01 1-131 -3.89E-03 1.10E-02 4.26E-02 CF 04 61191 07/25/01 1-131 -1.99E-03 1.14E-02 4.34E-02 CF 05 61192 07/25/01 1-131 -1.91E-03 1.16E-02 4.38E-02 CF 06 61193 07/25/01 1-131 1.68E-02 1.08E-02 3.52E-02 CF 07 61194 07/25/01 1-131 1.31E-02 8.99E-03 2.98E-02 CF 08 61195 07/25/01 1-131 -3.69E-03 1.08E-02 4.14E-02
- Concentration Greater than 3 Standard Deviations 36
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 61310 08/01/01 1-131 5.02E-03 9.33E-03 3.37E-02 CF 02 61311 08/01/01 1-131 -1.62E-03 9.31E-03 3.55E-02 CF 03 61312 08/01/01 1-131 1.80E-03 1.10E-02 4.05E-02 CF 04 61313 08/01/01 1-131 0.OOE+00 1.48E-02 5.37E-02 CF 05 61314 08/01/01 1-131 1.91E-02 1.11E-02 3.60E-02 CF 06 61315 08/01/01 1-131 1.73E-03 1.05E-02 3.88E-02 CF 07 61316 08/01/01 1-131 2.06E-02 1.14E-02 3.65E-02 CF 08 61317 08/01/01 1-131 5.26E-03 1.04E-02 3.74E-02 CF 01 61428 08/07/01 1-131 -2.91E-03 1.09E-02 4.04E-02 CF 02 61429 08/08/01 1-131 -4.16E-03 1.01E-02 3.78E-02 CF 03 61430 08/08/01 1-131 2.15E-02 1.06E-02 3.36E-02 CF 04 61431 08/08/01 1-131 -7.53E-03 1.08E-02 4.12E-02 CF 05 61432 08/08/01 1-131 -4.68E-03 1.09E-02 4.12E-02 CF 06 61433 08/08/01 1-131 9.20E-03 1.04E-02 3.61E-02 CF 07 61434 08/08/01 1-131 -1.55E-03 1.17E-02 4.30E-02 CF 08 61435 08/08/01 1-131 1.40E-02 9.19E-03 3.03E-02 CF 01 61484 08/15/01 1-131 8.23E-03 1.08E-02 3.78E-02 CF 02 61485 08/15/01 1-131 -1.62E-03 9.61E-03 3.65E-02 CF 03 61486 08/15/01 1-131 3.25E-03 8.59E-03 3.16E-02 CF 04 61487 08/15/01 1-131 -4.79E-03 8.60E-03 3.41E-02 CF 05 61488 08/15/01 1-131 -1.23E-02 1.25E-02 4.87E-02 CF 06 61489 08/15/01 1-131 1.02E-02 1.15E-02 3.98E-02 CF 07 61490 08/15/01 1-131 -6.83E-03 1.03E-02 4.02E-02 CF 08 61491 08/15/01 1-131 -3.43E-03 1.06E-02 4.03E-02 CF 01 61556 08/22/01 1-131 4.42E-03 8.71E-03 3.14E-02 CF 02 61557 08/22/01 1-131 -1.44E-02 9.13E-03 3.75E-02 CF 03 61558 08/22/01 1-131 -2.97E-03 9.62E-03 3.64E-02 CF 04 61559 08/22/01 1-131 4.38E-03 9.11E-03 3.28E-02 CF 05 61560 08/22/01 1-131 1.40E-02 1.11E-02 3.75E-02 CF 06 61561 08/22/01 1-131 -7.34E-03 9.72E-03 3.91E-02 CF 07 61562 08/22/01 1-131 1.80E-03 9.02E-03 3.40E-02 CF 08 61563 08/22/01 1-131 -5.42E-03 9.73E-03 3.85E-02 CF 02 61655 08/29/01 1-131 -4.19E-03 9.98E-03 3.76E-02 CF 03 61656 08/29/01 1-131 -5.87E-03 1.06E-02 4.01E-02 CF 04 61657 08/29/01 1-131 -1.32E-02 1.03E-02 4.08E-02 CF 05 61658 08/29/01 1-131 1.80E-02 1.20E-02 3.97E-02 CF 06 61659 08/29/01 1-131 1.49E-03 1.11E-02 4.01E-02 CF 07 61660 08/29/01 1-131 2.92E-03 1.11E-02 3.99E-02 CF 08 61661 08/29/01 1-131 1.05E-02 9.85E-03 3.37E-02
- Concentration Greater than 3 Standard Deviations 37
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 61802 09/05/01 1-131 -2.12E-02 1.29E-02 5.25E-02 CF 02 61803 09/05/01 1-131 -5.22E-03 1.l1E-02 4.27E-02 CF 03 61804 09/05/01 1-131 1.62E-02 1.15E-02 3.83E-02 CF 04 61805 09/05/01 1-131 -3.47E-03 1.13E-02 4.26E-02 CF 05 61806 09/05/01 1-131 -1.34E-02 1.29E-02 5.06E-02 CF 06 61807 09/05/01 1-131 -1.89E-03 1.09E-02 4.14E-02 CF 07 61808 09/05/01 1-131 -1.97E-02 9.31E-03 4.12E-02 CF 08 61809 09/05/01 1-131 1.91E-03 1.13E-02 4.17E-02 CF 01 61855 09/12/01 1-131 1.47E-02 7.70E-03 2.43E-02 CF 02 61856 09/12/01 1-131 1.60E-02 1.04E-02 3.43E-02 CF 03 61857 09/12/01 1-131 -3.09E-03 9.78E-03 3.72E-02 CF 04 61858 09/12/01 1-131 -1.53E-03 9.80E-03 3.68E-02 CF 05 61859 09/12/01 1-131 -1.57E-02 1.07E-02 4.29E-02 CF 06 61860 09/12/01 1-131 -1.71E-02 1.05E-02 4.26E-02 CF 07 61861 09/12/01 1-131 -5.66E-03 9.59E-03 3.67E-02 CF 08 61862 09/12/01 1-131 4.69E-03 9.25E-03 3.33E-02 CF 01 61993 09/19/01 1-131 -1.01E-02 1.01E-02 3.93E-02 CF 02 61994 09/19/01 1-131 -1.42E-03 8.15E-03 3.10E-02 CF 03 61995 09/19/01 1-131 -4.33E-03 1.07E-02 4.01E-02 CF 04 61996 09/19/01 1-131 -1.41E-02 9.78E-03 3.92E-02 CF 05 61997 09/19/01 1-131 -4.59E-03 1.15E-02 4.31E-02 CF 06 61998 09/19/01 1-131 -1.38E-02 1.08E-02 4.27E-02 CF 07 61999 09/19/01 1-131 1.15E-02 9.33E-03 3.15E-02 CF 08 62000 09/19/01 1-131 1.23E-02 8.94E-03 2.99E-02 CF 01 62166 09/26/01 1-131 1.71E-02 1.42E-02 4.80E-02 CF 02 62167 09/26/01 1-131 -9.57E-03 1.24E-02 4.77E-02 CF 03 62168 09/26/01 1-131 4.78E-03 1.41E-02 5.03E-02 CF 04 62169 09/26/01 1-131 -4.28E-03 1.40E-02 5.18E-02 CF 05 62170 09/26/01 1-131 -1.60E-02 1.42E-02 5.52E-02 CF 06 62171 09/26/01 1-131 -7.60E-04 1.54E-02 5.59E-02 CF 07 62172 09/26/01 1-131 -4.28E-03 1.31E-02 4.88E-02 CF 08 62173 09/26/01 1-131 1.07E-02 1.40E-02 4.89E-02 CF 01 62182 10/03/01 1-131 2.29E-03 1.19E-02 4.46E-02 CF 02 62183 10/03/01 1-131 2.14E-02 1.53E-02 5.10E-02 CF 03 62184 10/03/01 1-131 -6.58E-03 1.61E-02 6.41E-02 CF 04 62185 10/03/01 1-131 -9.63E-03 1.40E-02 5.82E-02 CF 05 62186 10/03/01 1-131 1.64E-02 1.18E-02 3.93E-02 CF 06 62187 10/03/01 1-131 0.OOE+00 1.25E-02 5.02E-02 CF 07 62188 10/03/01 1-131 6.22E-03 1.39E-02 5.18E-02 CF 08 62189 10/03/01 1-131 -2.67E-02 1.56E-02 6.91E-02
- Concentration Greater than 3 Standard Deviations 38
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 62361 10/10/01 1-131 -1.18E-02 1.40E-02 5.66E-02 CF 02 62362 10/10/01 1-131 1.27E-03 1.06E-02 4.16E-02 CF 03 62363 10/10/01 1-131 9.03E-03 1.34E-02 4.82E-02 CF 04 62364 10/10/01 1-131 1.20E-03 1.23E-02 4.69E-02 CF 05 62365 10/10/01 1-131 6.29E-04 1.11E-02 4.21E-02 CF 06 62366 10/10/01 1-131 6.09E-04 1.15E-02 4.32E-02 CF 07 62367 10/10/01 1-131 -8.03E-03 9.88E-03 4.13E-02 CF 08 62368 10/10/01 1-131 1.28E-02 1.14E-02 3.93E-02 CF 01 62467 10/17/01 1-131 4.80E-03 1.05E-02 3.76E-02 CF 02 62468 10/17/01 1-131 6.74E-03 9.23E-03 3.28E-02 CF 03 62469 10/17/01 1-131 5.23E-03 9.06E-03 3.28E-02 CF 04 62470 10/17/01 1-131 -5.OOE-03 9.57E-03 3.74E-02 CF 05 62471 10/17/01 1-131 -1.02E-02 9.61E-03 3.91E-02 CF 06 62472 10/17/01 1-131 -1.74E-02 9.86E-03 4.19E-02 CF 07 62473 10/17/01 1-131 0.OOE+00 8.19E-03 3.13E-02 CF 08 62474 10/17/01 1-131 -3.44E-03 9.09E-03 3.56E-02 CF 01 62552 10/23/01 1-131 -3.90E-03 1.43E-02 5.47E-02 CF 02 62553 10/23/01 1-131 -1.16E-02 1.48E-02 5.84E-02 CF 03 62554 10/23/01 1-131 2.95E-03 1.12E-02 4.16E-02 CF 04 62555 10/23/01 1-131 -9.43E-03 1.13E-02 4.55E-02 CF 05 62556 10/23/01 1-131 -8.08E-03 1.09E-02 4.45E-02 CF 06 62557 10/23/01 1-131 1.12E-02 1.30E-02 4.61E-02 CF 07 62558 10/23/01 1-131 -3.34E-03 1.08E-02 4.22E-02 CF 08 62559 10/23/01 1-131 -1.20E-02 1.24E-02 5.18E-02 CF 01 62685 10/31/01 1-131 1.57E-02 9.94E-03 3.26E-02 CF 02 62686 10/31/01 1-131 -1.66E-03 1.07E-02 4.OOE-02 CF 03 62687 10/31/01 1-131 0.OOE+00 1.12E-02 4.17E-02 CF 04 62688 10/31/01 1-131 1.76E-03 1.13E-02 4.14E-02 CF 05 62689 10/31/01 1-131 -7.42E-03 1.17E-02 4.55E-02 CF 06 62690 10/31/01 1-131 -1.46E-02 1.21E-02 4.81E-02 CF 07 62691 10/31/01 1-131 7.31E-03 1.18E-02 4.20E-02 CF 08 62692 10/31/01 1-131 0.OOE+00 1.OOE-02 3.79E-02 CF 01 62827 11/07/01 1-131 0.OOE+00 1.28E-02 5.12E-02 CF 02 62828 11/07/01 1-131 7.88E-03 1.08E-02 3.94E-02 CF 03 62829 11/07/01 1-131 0.OOE+00 1.01E-02 4.02E-02 CF 04 62830 11/07/01 1-131 1.39E-02 1.47E-02 5.21E-02 CF 05 62831 11/07/01 1-131 -1.05E-02 9.86E-03 4.39E-02 CF 06 62832 11/07/01 1-131 1.31E-02 1.14E-02 3.92E-02 CF 07 62833 11/07/01 1-131 5.25E-03 9.10E-03 3.44E-02 CF 08 62834 11/07/01 1-131 -2.87E-03 1.44E-02 5.60E-02
- Concentration Greater than 3 Standard Deviations 39
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 62919 11/14/01 1-131 -5.39E-03 8.44E-03 3.29E-02 CF 02 62920 11/14/01 1-131 6.12E-03 9.93E-03 3.51E-02 CF 03 62921 11/14/01 1-131 4.81E-03 9.95E-03 3.56E-02 CF 04 62922 11/14/01 1-131 -4.28E-03 9.63E-03 3.68E-02 CF 05 62923 11/14/01 1-131 -1.33E-02 8.99E-03 3.71E-02 CF 06 62924 11/14/01 1-131 -6.18E-03 9.68E-03 3.78E-02 CF 07 62925 11/14/01 1-131 -1.04E-02 8.53E-03 3.50E-02 CF 08 62926 11/14/01 1-131 -7.66E-03 1.02E-02 3.96E-02 CF 01 63007 11/21/01 1-131 1.11E-02 1.11E-02 3.84E-02 CF 02 63008 11/21/01 1-131 5.87E-03 1.22E-02 4.39E-02 CF 03 63009 11/21/01 1-131 3.78E-03 1.22E-02 4.44E-02 CF 04 63010 11/21/01 1-131 1.65E-02 1.23E-02 4.11E-02 CF 05 63011 11/21/01 1-131 0.OOE+00 1.28E-02 4.76E-02 CF 06 63012 11/21/01 1-131 1.99E-03 1.15E-02 4.25E-02 CF 07 63013 11/21/01 1-131 -1.90E-03 1.09E-02 4.16E-02 CF 08 63014 11/21/01 1-131 -2.87E-02 1.51E-02 6.12E-02 CF 01 63094 11/28/01 1-131 1.74E-02 7.91E-03 2.37E-02 CF 02 63095 11/28/01 1-131 -8.32E-03 8.65E-03 3.55E-02 CF 03 63096 11/28/01 1-131 0.OOE+00 1.11E-02 4.10E-02 CF 04 63097 11/28/01 1-131 3.34E-03 8.18E-03 3.03E-02 CF 05 63098 11/28/01 1-131 -5.10E-03 1.01E-02 3.91E-02 CF 06 63099 11/28/01 1-131 1.56E-02 1.21E-02 4.07E-02 CF 07 63100 11/28/01 1-131 -1.16E-02 9.22E-03 3.81E-02 CF 08 63101 11/28/01 1-131 1.07E-02 1.19E-02 4.11E-02 CF 01 63189 12/05/01 1-131 -4.56E-03 9.13E-03 3.60E-02 CF 02 63190 12/05/01 1-131 -1.73E-02 1.05E-02 4.38E-02 CF 03 63191 12/05/01 1-131 2.39E-02 1.10E-02 3.37E-02 CF 04 63192 12/05/01 1-131 9.41E-03 1.02E-02 3.57E-02 CF 05 63193 12/05/01 1-131 1.72E-03 6.44E-03 2.29E-02 CF 06 63194 12/05/01 1-131 -2.91E-03 7.08E-03 2.59E-02 CF 07 63195 12/05/01 1-131 -1.03E-02 6.75E-03 2.61E-02 CF 08 63196 12/05/01 1-131 1.28E-02 7.18E-03 2.33E-02 CF 01 63334 12/12/01 1-131 1.55E-03 8.90E-03 3.30E-02 CF 02 63335 12/12/01 1-131 0.OOE+00 9.84E-03 3.67E-02 CF 03 63336 12/12/01 1-131 -1.58E-03 1.04E-02 3.88E-02 CF 04 63337 12/12/01 1-131 1.09E-02 8.97E-03 3.04E-02 CF 05 63338 12/12/01 1-131 5.48E-03 9.83E-03 3.56E-02 CF 06 63339 12/12/01 1-131 1.73E-03 9.95E-03 3.69E-02 CF 07 63340 12/12/01 1-131 0.OOE+00 8.99E-03 3.39E-02 CF 08 63341 12/12/01 1-131 6.76E-03 1.04E-02 3.70E-02
- Concentration Greater than 3 Standard Deviations 40
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CHARCOAL FILTERS CF 01 63416 12/19/01 1-131 4.77E-03 1.07E-02 3.82E-02 CF 02 63417 12/19/01 1-131 1.50E-02 1.06E-02 3.54E-02 CF 03 63418 12/19/01 1-131 -5.12E-03 1.15E-02 4.36E-02 CF 04 63419 12/19/01 1-131 -8.36E-03 1.07E-02 4.19E-02 CF 05 63420 12/19/01 1-131 1.47E-02 1.19E-02 4.03E-02 CF 06 63421 12/19/01 1-131 5.20E-03 1.29E-02 4.58E-02 CF 07 63422 12/19/01 1-131 1.69E-02 1.69E-02 6.08E-02 CF 08 63423 12/19/01 1-131 -1.75E-02 1.02E-02 4.30E-02 CF 01 63512 12/26/01 1-131 -1.88E-02 9.25E-03 3.82E-02 CF 02 63513 12/26/01 1-131 -1.46E-03 9.48E-03 3.53E-02 CF 03 63514 12/26/01 1-131 1.25E-02 9.11E-03 3.04E-02 CF 04 63515 12/26/01 1-131 -1.43E-03 9.10E-03 3.40E-02 CF 05 63516 12/26/01 1-131 -2.79E-02 1.08E-02 4.54E-02 CF 06 63517 12/26/01 1-131 -4.43E-03 8.80E-03 3.41E-02 CF 07 63518 12/26/01 1-131 9.93E-03 9.55E-03 3.27E-02 CF 08 63519 12/26/01 1-131 1.16E-02 1.05E-02 3.56E-02 CF 01 63577 01/02/02 1-131 8.07E-03 1.01E-02 3.54E-02 CF 02 63578 01/02/02 1-131 1.65E-02 1.02E-02 3.32E-02 CF 03 63579 01/02/02 1-131 -9.77E-03 1.00E-02 4.OOE-02 CF 04 63580 01/02/02 1-131 6.43E-03 7.54E-03 2.68E-02 CF 05 63581 01/02/02 1-131 -1.92E-02 9.08E-03 4.02E-02 CF 06 63582 01/02/02 1-131 5.23E-03 9.71E-03 3.51E-02 CF 07 63583 01/02/02 1-131 1.03E-02 1.18E-02 4.07E-02 CF 08 63584 01/02/02 1-131 1.33E-02 1.14E-02 3.84E-02
- Concentration Greater than 3 Standard Deviations 41
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) FISH FH 03 60422 05/29/01 Th-232 9. 83E+00 4. 54E+01 1. 70E+02 FH 03 60422 05/29/01 Ag-IIOM 1.76E+01 1. 54E+01 5.28E+01 FH 03 60422 05/29/01 Ba-140 -5. 90E+00 3. 35E+01 1.46E+02 FH 03 60422 05/29/01 Be-7 -3. 69E+01 1. 08E+02 4. 14E+02 FH 03 60422 05/29/01 Ce-141 -0. 35E+00 1. 91E+01 6.88E+01 FH 03 60422 05/29/01 Ce-144 6. 76E+01 5. 31E+01 1. 78E+02 FH 03 60422 05/29/01 Co-57 -7 .43E+00 6. 51E+00 2. 48E+01 FH 03 60422 0/29/01 Co-58 1.82E+01 1. 45E+01 4. 92E+01 FH 03 60422 05/29/01 Co-60 7. 82E+00 1. 25E+01 4. 64E+01 FH 03 60422 0/29/01 Cr-51 1. 31E+02 1.29E+02 4 41E+02 FH 03 60422 05/29/01 Cs-134 6. O1E+00 1. 11E+01 4. 10E+01 FH 03 60422 05/29/01 Cs-137 2. 91E+00 1. 13E+01 4. 21E+01 FH 03 60422 05/29/01 Fe-59 5. 25E+00 3. 33E+01 1. 35E+02 FH 03 60422 05/29/01 1-131 1. O1E+02 6. 40E+01 2. 10E+02 FH 03 60422 05/29/01 K-40 3. 60E+03 3. 85E+02 6.57E+02
- FH 03 60422 05/29/01 Mn-54 -1.89E+01 1. 01E+01 4. 61E+01 FH 03 60422 05/29/01 Ru-103 -9. 91E+00 1.57E+01 6.08E+01 FH 03 60422 05/29/01 Ru-106 -1.22E+02 1.06E+02 4. 32E+02 FH 03 60422 05/29/01 Sb-124 -2. 10E+01 2. 10E+01 1. 13E+02 FH 03 60422 05/29/01 Se-75 -1.21E+01 1. 37E+01 5. 22E+01 FH 03 60422 05/29/01 Zn-65 -5. 95E+01 2. 79E+01 1. 27E+02 FH 03 60422 05/29/01 Zr-95 -1. 14E+01 2. 08E+01 8.57E+01 FH 03 61542 08/21/01 Th-232 -2. 75E+01 5. 17E+01 2. 05E+02 FH 03 61542 08/21/01 Ag-11OM 1. 94E+01 1. 69E+01 5. 82E+01 FH 03 61542 08/21/01 Ba-140 -5. 29E+00 2.20E+01 9. 97E+01 FH 03 61542 08/21/01 Be-7 0. 00E+00 9. 21E+01 3. 54E+02 FH 03 61542 08/21/01 Ce-141 1. 36E+01 1.89E+01 6. 53E+01 FH 03 61542 08/21/01 Ce-144 1. OOE+01 6. 29E+01 2.23E+02 FH 03 61542 08/21/01 Co-57 -0. 28E+00 7.83E+00 2. 81E+01 FH 03 61542 08/21/01 Co-58 -8. 98E+00 1.33E+01 5.47E+01 FH 03 61542 08/21/01 Co-60 1. 66E+01 1.39E+01 4. 76E+01 FH 03 61542 08/21/01 Cr-51 1. 57E+02 1. 32E+02 4 46E+02 FH 03 61542 08/21/01 Cs-134 1. 73E+01 1.26E+01 4. 21E+01 FH 03 61542 08/21/01 Cs-137 -4. 50E+00 1.25E+01 4. 93E+01 FH 03 61542 08/21/01 Fe-59 4 .4 6E+01 4.53E+01 1. 59E+02 FH 03 61542 08/21/01 1-131 -1.24E+02 4.31E+01 1 . 84E+02 FH 03 61542 08/21/01 K-40 3. 48E+03 3. 98E+02 6.62E+02
- FH 03 61542 08/21/01 Mn-54 -6. 19E+00 1. 14E+01 4. 67E+01 FH 03 61542 08/21/01 Ru-103 7. 32E+00 1.31E+01 4. 75E+01 FH 03 61542 08/21/01 Ru-106 -6. 61E+01 1. 14E+02 4. 50E+02 FH 03 61542 08/21/01 Sb-124 -1. 08E+01 2. 86E+01 1. 30E+02 FH 03 61542 08/21/01 Se-75 -9. 30E+00 1. 43E+01 5.40E+01 FH 03 61542 08/21/01 Zn-65 -4. 58E+01 2. 85E+01 1.28E+02 FH 03 61542 08/21/01 Zr-95 -3. 97E+01 2. 12E+01 9. 70E+01
- Concentration Greater than 3 Standard Deviations 42
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) FISH FH 03 63068 11/26/01 Th-232 1. 05E+02 4.86E+01 1.48E+02 FH 03 63068 11/26/01 Ag-lIOM 0. OOE+00 1. 99E+01 7. 54E+01 FH 03 63068 11/26/01 Ba-140 2. 38E+01 2. 38E+01 8. 74E+01 FH 03 63068 11/26/01 Be-7 0.OOE+00 9. 19E+01 3. 51E+02 FH 03 63068 11/26/01 Ce-141 2. 10E+01 1. 87E+01 6. 30E+01 FH 03 63068 11/26/01 Ce-144 -3. 26E+01 4.45E+01 1. 68E+02 FH 03 63068 11/26/01 Co-57 -1. 68E+00 6.18E+00 2.25E+01 FH 03 63068 11/26/01 Co-58 -4. 62E+00 1. 15E+01 4. 74E+01 FH 03 63068 11/26/01 Co-60 -0. 91E+00 7.73E+00 3. 60E+01 FH 03 63068 11/26/01 Cr-51 -5. 18E+01 1. 05E+02 4. 06E+02 FH 03 63068 11/26/01 Cs-134 9. 13E+00 1.25E+01 4 51E+01 FH 03 63068 11/26/01 Cs-137 -8. 66E+00 1. 11E+01 4. 53E+01 FH 03 63068 11/26/01 Fe-59 -8 40E+00 4. 13E+01 1. 70E+02 FH 03 63068 11/26/01 1-131 -3. 33E+01 5. 52E+01 2. 12E+02 FH 03 63068 11/26/01 K-40 3. 36E+03 3. 70E+02 4 83E+02 FH 03 63068 11/26/01 Mn-54 1.24E+01 1. 19E+01 4 .13E+01 FH 03 63068 11/26/01 Ru-103 1. 68E+01 1. 25E+01 4 19E+01 FH 03 63068 11/26/01 Ru-106 -3. 85E+01 1. 03E+02 4 01E+02 FH 03 63068 11/26/01 Sb-124 -1. 16E+01 2. 59E+01 1. 25E+02 FH 03 63068 11/26/01 Se-75 -4 87E+00 1. 14E+01 4. 29E+01 FH 03 63068 11/26/01 Zn-65 6. 42E+00 2. 94E+01 1. 12E+02 FH 03 63068 11/26/01 Zr-95 1. 04E+01 2. 01E+01 7. 52E+01 FH 53 60127 05/21/01 Th-232 -1. 96E+01 3. 29E+01 1. 31E+02 FH 53 60127 05/21/01 Ag-IIOM -4. 73E+00 1. 26E+01 4. 93E+01 FH 53 60127 05/21/01 Ba-140 7. 35E+00 2. 65E+01 1. 04E+02 FH 53 60127 05/21/01 Be-7 -1. 06E+02 7 72E+01 3. 18E+02 FH 53 60127 05/21/01 Ce-141 -2. OOE+01 1. 59E+01 6. 01E+01 FH 53 60127 05/21/01 Ce-144 8. 21E+00 4. 91E+01 1.74E+02 FH 53 60127 05/21/01 Co-57 -4 80E+00 5. 84E+00 2. 17E+01 FH 53 60127 05/21/01 Co-58 -3. 61E+00 9. 81E+00 3. 86E+01 FH 53 60127 05/21/01 Co-60 5. 68E+00 7. 88E+00 2. 92E+01 FH 53 60127 05/21/01 Cr-51 8. 13E+01 1. 13E+02 3. 93E+02 FH 53 60127 05/2 1/01 Cs-134 0 .4 6E+00 9. 99E+00 3. 77E+01 FH 53 60127 05/21/01 Cs-137 -1. 65E+01 1.20E+01 4. 70E+01 FH 53 60127 05/21/01 Fe-59 -7 . 07E+00 3. 15E+01 1.25E+02 FH 53 60127 05/21/01 1-131 6. 54E+00 4 .85E+01 1.76E+02 FH 53 60127 05/21/01 K-40 3. 63E+03 3. 17E+02 5. 05E+02
- FH 53 60127 05/21/01 Mn-54 -1. 67E+00 8. 37E+00 3. 26E+01 FH 53 60127 05/21/01 Ru-103 3. 52E+00 1. 03E+01 3. 76E+01 FH 53 60127 05/21/01 Ru-106 2. 90E+01 9. 17E+01 3. 31E+02 FH 53 60127 05/21/01 Sb-124 -7. OOE+00 1. 85E+01 8. 41E+01 FH 53 60127 05/21/01 Se-75 -2. 61E+00 1.21E+01 4. 37E+01 FH 53 60127 05/21/01 Zn-65 -1. 98E+01 5. 71E+01 2. 01E+02 FH 53 60127 05/21/01 Zr-95 2. 63E+01 1. 70E+01 5. 55E+01
- Concentration Greater than 3 Standard Deviations 43
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) FISH FH 53 61543 08/21/01 Th-232 -6. 75E+01 5. 93E+01 2.43E+02 FH 53 61543 08/21/01 Ag-lIOM -8. 21E+00 1. 54E+01 6. 52E+01 FH 53 61543 08/21/01 Ba-140 0. OOE+00 2. 03E+01 9. 41E+01 FH 53 61543 08/21/01 Be-7 0. OOE+00 9. 03E+01 3. 49E+02 FH 53 61543 08/21/01 Ce-141 -4. 91E+00 1. 60E+01 5. 86E+01 FH 53 61543 08/21/01 Ce-144 -2. 15E+01 4. 96E+01 1. 84E+02 FH 53 61543 08/21/01 Co-57 -4. 69E+00 6. 16E+00 2. 33E+01 FH 53 61543 08/21/01 Co-58 7. 33E+00 1.40E+01 5. 15E+01 FH 53 61543 08/21/01 Co-60 1. 20E+01 9. 54E+00 3. 24E+01 FH 53 61543 08/21/01 Cr-51 3. 45E+01 1. 01E+02 3. 68E+02 FH 53 61543 08/21/01 Cs-134 2. 31E+01 1. 16E+01 3. 44E+01 FH 53 61543 08/21/01 Cs-137 -7. 77E+00 1. 35E+01 5. 39E+01 FH 53 61543 08/21/01 Fe-59 -9. 73E+01 4. 67E+01 2.22E+02 FH 53 61543 08/21/01 1-131 -1. 19E+01 2. 79E+01 1. 12E+02 FH 53 61543 08/21/01 K-40 3. 94E+03 4. 38E+02 6.40E+02
- FH 53 61543 08/21/01 Mn-54 8.42E+00 1. 29E+01 4.68E+01 FH 53 61543 08/21/01 Ru-103 2. 51E+00 1 .25E+01 4.72E+01 FH 53 61543 08/21/01 Ru-106 1.09E+01 1. 05E+02 4. 02E+02 FH 53 61543 08/21/01 Sb-124 -1.25E+01 3. 74E+01 1. 63E+02 FH 53 61543 08/21/01 Se-75 1.80E+00 1. 24E+01 4.51E+01 FH 53 61543 08/21/01 Zn-65 0 . OOE+00 2. 71E+01 1.09E+02 FH 53 61543 08 /21/01 Zr-95 0. 66E+00 2. 04E+01 8. 13F+01 FH 53 63067 11/19/01 Th-232 -4.4 9E+00 4 45E+01 1. 70E+02 FH 53 63067 11/19/01 Ag-IIOM -1. 45E+01 1. 56E+01 6. 51E+01 FH 53 63067 11/19/01 Ba-140 4 . 05E+01 4. 66E+01 1.71E+02 FH 53 63067 11/19/01 Be-7 -7.52E+01 1. 50E+02 5. 61E+02 FH 53 63067 11/19/01 Ce-141 2.01E+01 2. 90E+01 9. 89E+01 FH 53 63067 11/19/01 Ce-144 -3.21E+01 7. 58E+01 2 69E+02 FH 53 63067 11/19/01 Co-57 9. 35E+00 8. 52E+00 2. 87E+01 FH 53 63067 11/19/01 Co-58 -1. 10E+01 1. 41E+01 5. 71E+01 FH 53 63067 11/19/01 Co-60 6. 28E+00 1. 17E+01 4 .43E+01 FH 53 63067 11/19/01 Cr-51 3. 10E+02 1. 75E+02 5. 68E+02 FH 53 63067 11/19/01 Cs-134 0 OOE+00 1. 35E+01 5. 11E+01 FH 53 63067 11/19/01 Cs-137 -1. 46E+01 1. 16E+01 4. 78E+01 FH 53 63067 11/19/01 Fe-59 0. OOE+00 4. 34E+01 1. 72E+02 FH 53 63067 11/19/01 1-131 -1. 34E+01 9. 67E+01 3. 63E+02 FH 53 63067 11/19/01 K-40 3 43E+03 3. 57E+02 5. 51E+02
- FH 53 63067 11/19/01 Mn-54 -1. 93E+01 1. 42E+01 5. 77E+01 FH 53 63067 11/19/01 Ru-103 2. 59E+00 1. 66E+01 6. 09E+01 FH 53 63067 11/19/01 Ru-106 -1. 45E+02 1. 09E+02 4. 44E+02 FH 53 63067 11/19/01 Sb-124 6. 27E+01 3. 04E+01 8. 19E+01 FH 53 63067 11/19/01 Se-75 -1. 69E+00 1.74E+01 6. 20E+01 FH 53 63067 11/19/01 Zn-65 -3. 50E+01 2. 95E+01 1. 23E+02 FH 53 63067 11/19/01 Zr-95 2. 41E+01 2. 69E+01 9. 40E+01
- Concentration Greater than 3 Standard Deviations 44
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) LOBSTER HA 04 60397 06/06/01 Th-232 4. 91E+00 3. 97E+01 1. 55E+02 HA 04 60397 06/06/01 Ag-IIOM 2. 36E+01 1.30E+01 3. 95E+01 HA 04 60397 06/06/01 Ba-140 2. 80E+01 2.09E+01 6. 87E+01 HA 04 60397 06/06/01 Be-7 3. 56E+01 7. 96E+01 2. 97E+02 HA 04 60397 06/06/01 Ce-141 -1. 78E+01 1.54E+01 5. 86E+01 HA 04 60397 06/06/01 Ce-144 -2. 39E+00 4.78E+01 1.73E+02 HA 04 60397 06/06/01 Co-57 -9. 39E+00 5. 31E+00 2. 13E+01 HA 04 60397 06/06/01 Co-58 7.14E+00 1. 35E+01 4. 94E+01 HA 04 60397 06/06/01 Co-60 -1. 92E+00 1. 16E+01 4. 96E+01 HA 04 60397 06/06/01 Cr-51 -3. 19E+01 1 01E+02 3. 83E+02 HA 04 60397 06/06/01 Cs-134 9. 75E+00 1. 17E+01 4.22E+01 HA 04 60397 06/06/01 Cs-137 -5. 99E+00 1. 08E+01 4.41E+01 HA 04 60397 06/06/01 Fe-59 -3. 95E+01 3. 15E+01 1. 54E+02 HA 04 60397 06/06/01 1-131 -5.47E+00 3. 42E+01 1.29E+02 HA 04 60397 06/06/01 K-40 2. 01E+03 2. 98E+02 4.42E+02
- HA 04 60397 06/06/01 Mn-54 5. 20E+00 8. 22E+00 3. 12E+01 HA 04 60397 06/06/01 Ru-103 9. 27E+00 1. 14E+01 4. 04E+01 HA 04 60397 06/06/01 Ru-106 6. 75E+01 1. 08E+02 3. 90E+02 HA 04 60397 06/06/01 Sb-124 0. 00E+00 1. 63E+01 8.49E+01 HA 04 60397 06/06/01 Se-75 -1. 34E+01 1. 11E+01 4.43E+01 HA 04 60397 06/06/01 Zn-65 -6. 04E+01 2. 23E+01 1. 17E+02 HA 04 60397 06/06/01 Zr-95 6. 13E+00 2. 06E+01 7.86E+01 HA 04 63069 11/27/01 Th-232 2. 58E+01 4. 41E+01 1. 62E+02 HA 04 63069 11/27/01 Ag-ilOM 3. 40E+01 1. 56E+01 4. 54E+01 HA 04 63069 11/27/01 Ba-140 8. 67E+00 2. 29E+01 9. 34E+01 HA 04 63069 11/27/01 Be-7 -1. 75E+01 7. 61E+01 3. 04E+02 HA 04 63069 11/27/01 Ce-141 -1. 57E+01 1.4 9E+01 5.63E+01 HA 04 63069 11/27/01 Ce-144 -2. 07E+01 4.82E+01 1.78E+02 HA 04 63069 11/27/01 Co-57 -9. 21E+00 5. 76E+00 2. 26E+01 HA 04 63069 11/27/01 Co-58 -5. 27E+00 1. 01E+01 4.32E+01 HA 04 63069 11/27/01 Co-60 6. 24E+00 1. 14E+01 4.42E+01 HA 04 63069 11/27/01 Cr-51 4. 62E+01 1. 03E+02 3. 70E+02 HA 04 63069 11/27/01 Cs-134 -1. 25E+01 1. 17E+01 5. 10E+01 HA 04 63069 11/27/01 Cs-137 2.79E+00 8. 88E+00 3. 44E+01 HA 04 63069 11/27/01 Fe-59 4 . OOE+01 3. 11E+01 1. 06E+02 HA 04 63069 11/27/01 1-131 0. OOE+00 2. 93E+01 1. 09E+02 HA 04 63069 11/27/01 K-40 1. 90E+03 3. 07E+02 5.74E+02
- HA 04 63069 11/27/01 Mn-54 0. OOE+00 1.03E+01 4 . 10E+01 HA 04 63069 11/27/01 Ru-103 1. 81E+01 1.20E+01 3. 93E+01 HA 04 63069 11/27/01 Ru-106 -3. 69E+01 1. 03E+02 4. 04E+02 HA 04 63069 11/27/01 Sb-124 -2. 27E+01 3. 93E+01 1.70E+02 HA 04 63069 11/27/01 Se-75 1. 16E+01 1. 18E+01 4. 06E+01 HA 04 63069 11/27/01 Zn-65 0. OOE+00 2. 49E+01 1. 00E+02 HA 04 63069 11/27/01 Zr-95 2. 17E+01 1. 60E+01 5. 37E+01
- Concentration Greater than 3 Standard Deviations 45
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) LOBSTER HA 54 60398 06/06/01 Th-232 -1. 66E+01 4.48E+01 1.80E+02 HA 54 60398 06/06/01 Ag-11CM 0. 00E+00 1. 54E+01 6.12E+01 HA 54 60398 06/06/01 Ba-140 5. 60E+01 2. 64E+01 6.86E+01 HA 54 60398 06/06/01 Be-7 2. 19E+02 9.31E+01 2.74E+02 HA 54 60398 06/06/01 Ce-141 -3. 20E+01 1. 38E+01 5. 69E+01 HA 54 60398 06/06/01 Ce-144 -7.40E+01 4. 98E+01 1. 95E+02 HA 54 60398 06/06/01 Co-57 1. 02E+00 6. 12E+00 2.20E+01 HA 54 60398 06/06/01 Co-58 -1. 09E+01 1. 03E+01 4. 65E+01 HA 54 60398 06/06/01 Co-60 1. 02E+01 1.21E+01 4.47E+01 HA 54 60398 06/06/01 Cr-51 -4. 95E+01 1.11E+02 4.21E+02 HA 54 60398 06/06/01 Cs-134 4.72E+00 9.11E+00 3. 53E+01 HA 54 60398 06/06/01 Cs-137 8. 97E+00 1. 20E+01 4.28E+01 HA 54 60398 06/06/01 Fe-59 -4. 25E+01 3.94E+01 1. 77E+02 HA 54 60398 06/06/01 1-131 1. 61E+01 3.37E+01 1. 22E+02 HA 54 60398 06/06/01 K-40 1. 43E+03 3.08E+02 7 .52E+02
- HA 54 60398 06/06/01 Mn-54 2 42E+00 1.21E+01 4. 62E+01 HA 54 60398 06/06/01 Ru-103 -1. 43E+01 1. 01E+01 4 47E+01 HA 54 60398 06/06/01 Ru-106 -1. 24E+02 1. 02E+02 4. 31E+02 HA 54 60398 06/06/01 Sb-124 -1. 16E+01 2. 58E+01 1. 24E+02 HA 54 60398 06/06/01 Se-75 -6. 96E+00 1. 13E+01 4. 35E+01 HA 54 60398 06/06/01 Zn-65 0 OOE+00 2. 14E+01 8. 89E+01 HA 54 60398 06/06/01 Zr-95 -9. 97E+00 1. 66E+01 7.29E+01 HA 54 63103 11/28/01 Th-232 4.86E+01 3. 72E+01 1. 25E+02 HA 54 63103 11/28/01 Ag-11CM 1.79E+01 1. 38E+01 4 .63E+01 HA 54 63103 11/28/01 Ba-140 -6. 62E+00 1. 66E+01 7. 17E+01 HA 54 63103 11/28/01 Be-7 -7. 70E+01 7. 03E+01 2. 88E+02 HA 54 63103 11/28/01 Ce-141 0. 25E+00 1. 30E+01 4. 67E+01 HA 54 63103 11/28/01 Ce-144 1. 65E+01 4. 02E+01 1. 43E+02 HA 54 63103 11/28/01 Co-57 -1. 10E+00 5. 35E+00 1. 96E+01 HA 54 63103 11/28/01 Co-58 1. 10E+01 1. 03E+01 3. 53E+01 HA 54 63103 11/28/01 Co-60 -1 . 52E+00 8. 21E+00 3. 43E+01 HA 54 63103 11/28/01 Cr-51 -5. 95E+01 9. 14E+01 3.46E+02 HA 54 63103 11/28/01 Cs-134 5. 88E+00 7 .86E+00 2. 86E+01 HA 54 63103 11/28/01 Cs-137 -9. 88E+00 7. 94E+00 3.40E+01 HA 54 63103 11/28/01 Fe-59 -2. 52E+01 2. 18E+01 1.02E+02 HA 54 63103 11/28/01 1-131 3. 48E+00 2. 18E+01 8 .01E+01 HA 54 63103 11/28/01 K-40 2. 03E+03 2 70E+02 5.67E+02
- HA 54 63103 11/28/01 Mn-54 -3. 97E+00 8. 03E+00 3.26E+01 HA 54 63103 11/28/01 Ru-103 -1. 79E+01 1. 06E+01 4.36E+01 HA 54 63103 11/28/01 Ru-106 2. 16E+01 7. 08E+01 2. 65E+02 HA 54 63103 11/28/01 Sb-124 0. 00E+00 1.68E+01 7.39E+01 HA 54 63103 11/28/01 Se-75 -6. 92E+00 8. 38E+00 3. 30E+01 HA 54 63103 11/28/01 Zn-65 -5.22E+01 2.4 6E+01 1. 07E+02 HA 54 63103 11/28/01 Zr-95 4.41E+00 1.71E+01 6.37E+01
- Concentration Greater than 3 Standard Deviations 46
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MUSSELS MU 06 60122 05/21/01 Th-232 -1. 74E+01 3. 65E+01 1. 56E+02 MU 06 60122 05/21/01 Ag-lIOM 4 11E+00 9. 20E+00 3. 82E+01 MU 06 60122 05/21/01 Ba-140 -1. 34E+01 3. OOE+01 1. 44E+02 MU 06 60122 05/21/01 Be-7 -1. 65E+02 7. 73E+01 3. 75E+02 MU 06 60122 05/21/01 Ce-141 -1. 11E+01 1.70E+01 6.42E+01 MU 06 60122 05/21/01 Ce-144 4. 36E+01 5.26E+01 1. 82E+02 MU 06 60122 05/21/01 Co-57 -8. 76E+00 6.28E+00 2. 46E+01 MU 06 60122 05/21/01 Co-58 -4. 03E+00 9.4 4E+00 4.20E+01 MU 06 60122 05/21/01 Co-60 1. 48E+01 1. 34E+01 4. 69E+01 MU 06 60122 05/21/01 Cr-51 -1. 60E+02 1.39E+02 5.47E+02 MU 06 60122 05/21/01 Cs-134 8. 04E+00 1.01E+01 3. 72E+01 MU 06 60122 05/21/01 Cs-137 -1.24E+01 1.23E+01 5.15E+01 MU 06 60122 05/21/01 Fe-59 -8 82E+01 4. 39E+01 2. 15E+02 MU 06 60122 05/21/01 1-131 -1. 10E+01 5. 15E+01 1. 99E+02 MU 06 60122 05/21/01 K-40 8. 20E+02 2.4 6E+02 6.50E+02
- MU 06 60122 05/21/01 Mn-54 -2. 27E+01 1.13E+01 5.29E+01 MU 06 60122 05/21/01 Ru-103 1. 38E+01 1.26E+01 4. 38E+01 MU 06 60122 05/21/01 Ru-106 -1.28E+02 1. 03E+02 4.40E+02 MU 06 60122 05/21/01 Sb-124 -5. 18E+01 3. 66E+01 1. 83E+02 MU 06 60122 05/21/01 Se-75 -7. 55E+00 1.46E+01 5.48E+01 MU 06 60122 05/21/01 Zn-65 -3. 61E+01 2. 80E+01 1.26E+02 MU 06 60122 05/21/01 Zr-95 7. 66E+00 2.45E+01 9.29E+01 MU 06 63070 11/19/01 Th-232 2. 64E+01 3. 88E+01 4. 59E+02 MU 06 63070 11/19/01 Ag-IIOM -1. 34E+01 1.34E+01 5. 84E+01 MU 06 63070 11/19/01 Ba-140 2. 42E+01 4.20E+01 1. 59E+02 MU 06 63070 11/19/01 Be-7 -1.20E+02 9. 87E+01 4. 04E+02 MU 06 63070 11/19/01 Ce-141 1. 31E+01 1. 86E+01 6. 39E+01 MU 06 63070 11/19/01 Ce-144 -4 .85E+01 5. 02E+01 1. 88E+02 MU 06 63070 11/19/01 Co-57 5.39E+00 6. 01E+00 2. 06E+01 MU 06 63070 11/19/01 Co-58 -7. 32E+00 9. 84E+00 4. 27E+01 MU 06 63070 11/19/01 Co-60 4 . 54E+00 1. 21E+01 4. 65E+01 MU 06 63070 11/19/01 Cr-51 1.71E+01 1. 24E+02 4. 51E+02 MU 06 63070 11/19/01 Cs-134 4 . 04E+00 1. 19E+01 4.45E+01 MU 06 63070 11/19/01 Cs-137 -1. 56E+01 1. 40E+01 5. 55E+01 MU 06 63070 11/19/01 Fe-59 -3. 69E+01 2 . 59E+01 1. 36E+02 MU 06 63070 11/19/01 1-131 0. OOE+00 6. 08E+01 2. 25E+02 MU 06 63070 11/19/01 K-40 1. 36E+03 2 . 50E+02 5.17E+02
- MU 06 63070 11/19/01 Mn-54 1. 60E+01 1. 27E+01 4. 30E+01 MU 06 63070 11/19/01 Ru-103 -1. 16E+01 1. 25E+01 5. 07E+01 MU 06 63070 11/19/01 Ru-106 -8. 62E+01 8. 55E+01 3. 58E+02 MU 06 63070 11/19/01 Sb-124 -3.22E+01 2 84E+01 1. 41E+02 MU 06 63070 11/19/01 Se-75 6. 19E+00 1. 26E+01 4.43E+01 MU 06 63070 11/19/01 Zn-65 5.89E+00 3. 06E+01 1. 15E+02 MU 06 63070 11/19/01 Zr-95 -1. 44E+01 2. 14E+01 8.77E+01
- Concentration Greater than 3 Standard Deviations 47
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MUSSELS MU 56 60124 05/21/01 Th-232 0.28E+00 3. 93E+01 1. 52E+02 MU 56 60124 05/21/01 Ag-IIOM 1. 96E+01 1. 43E+01 4.77E+01 MU 56 60124 05/21/01 Ba-140 -3. 85E+01 1. 57E+01 9.45E+01 MU 56 60124 05/21/01 Be-7 1. 12E+02 9. 45E+01 3.21E+02 MU 56 60124 05/21/01 Ce-141 8 .80E+00 1.74E+01 6. 03E+01 MU 56 60124 05/21/01 Ce-144 2.88E+01 4.45E+01 1.56E+02 MU 56 60124 05/21/01 Co-57 0. OOE+00 6. 51E+00 2. 34E+01 MU 56 60124 05/21/01 Co-58 1. 41E+01 9. 67E+00 3.19E+01 MU 56 60124 05/21/01 Co-60 1. 35E+01 1.37E+01 4 .83E+01 MU 56 60124 05/21/01 Cr-51 -8.7 9E+01 9. 93E+01 3. 87E+02 MU 56 60124 05/21/01 Cs-134 4. 34E+00 1. 23E+01 4. 58E+01 MU 56 60124 05/21/01 Cs-137 -9. 18E+00 1. 18E+01 4. 72E+01 MU 56 60124 05/21/01 Fe-59 3. 34E+00 3. 12E+01 1. 25E+02 MU 56 60124 05/21/01 1-131 1. 39E+01 3. 17E+01 1. 13E+02 MU 56 60124 05/21/01 K-40 1.71E+03 2.74E+02 5.52E+02
- MU 56 60124 05/21/01 Mn-54 -1. 96E+00 8. 36E+00 3. 44E+01 MU 56 60124 05/21/01 Ru-103 -1. 03E+01 1.07E+01 4. 39E+01 MU 56 60124 05/21/01 Ru-106 -3.7 1E+01 1. 01E+02 3. 92E+02 MU 56 60124 05 /21/01 Sb-124 1.84E+01 1. 84E+01 6.78E+01 MU 56 60124 05 /21/01 Se-75 -1.59E+00 1.22E+01 4.49E+01 MU 56 60124 05 /21/01 Zn-65 0. OOE+00 2. 11E+01 8.45E+01 MU 56 60124 05 /21/01 Zr-95 -1. 69E+01 1.28E+01 6. 18E+01 MU 56 63071 11/19/01 Th-232 -2. 96E+01 3. 75E+01 1. 53E+02 MU 56 63071 11/19/01 Ag-IlOM 1. 81E+01 1. 13E+01 3. 62E+01 MU 56 63071 11/19/01 Ba-140 -1.91E+01 3. 81E+01 1. 59E+02 MU 56 63071 11/19/01 Be-7 -1.00E+02 1. 03E+02 4 . 10E+02 MU 56 63071 11/19/01 Ce-141 -8. 01E+01 2. 25E+01 9. 13E+01 MU 56 63071 11/19/01 Ce-144 -3. 09E+01 5. 45E+01 2. 02E+02 MU 56 63071 11/19/01 Co-57 8. 66E+00 7. 23E+00 2 43E+01 MU 56 63071 11/19/01 Co-58 -2 41E+00 1. 05E+01 4. 20E+01 MU 56 63071 11/19/01 Co-60 -3 65E+00 9. 16E+00 3 95E+01 MU 56 63071 11/19/01 Cr-51 -3. 47E+01 1. 32E+02 4. 89E+02 MU 56 63071 11/19/01 Cs-134 1. 14E+01 9. 38E+00 3. 21E+01 MU 56 63071 11/19/01 Cs-137 1. 30E+01 1. 01E+01 3 42E+01 MU 56 63071 11/19/01 Fe-59 3. 28E+01 3. 51E+01 1. 25E+02 MU 56 63071 11/19/01 1-131 5. 31E+01 6. 13E+01 2. 13E+02 MU 56 63071 11/19/01 K-40 1. 61E+03 2. 44E+02 4. 73E+02
- MU 56 63071 11/19/01 Mn-54 0. OOE+00 9. 72E+00 3. 76E+01 MU 56 63071 11/19/01 Ru-103 -2. 01E+01 1. 36E+01 5. 59E+01 MU 56 63071 11/19/01 Ru-106 1. 86E+02 8. 65E+01 2. 62E+02 MU 56 63071 11/19/01 Sb-124 3. 4 9E+00 3. 29E+01 1. 30E+02 MU 56 63071 11/19/01 Se-75 -1. 64E+01 1. 31E+01 5. 09E+01 MU 56 63071 11/19/01 Zn-65 -6. 78E+01 2 79E+01 1 . 24E+02 MU 56 63071 11/19/01 Zr-95 6. 32E+00 1. 94E+01 7. 29E+01
- Concentration Greater than 3 Standard Deviations 48
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MUSSELS MU 09 60125 05/23/01 Th-232 1. 66E+01 1. 83E+01 9. 25E+01 MU 09 60125 05/23/01 Ag-IIOM -2. 25E+00 6. 10E+00 2.22E+01 MU 09 60125 05/23/01 Ba-140 1. 36E+01 9. 68E+00 3.22E+01 MU 09 60125 05/23/01 Be-7 -3. 29E+01 3. 76E+01 1.37E+02 MU 09 60125 05/23/01 Ce-141 2. 56E+00 6. 83E+00 2.33E+01 MU 09 60125 05/23/01 Ce-144 1 .71E+00 2. 04E+01 7. 04E+01 MU 09 60125 05/23/01 Co-57 1. 66E+00 2. 72E+00 9. 22E+00 MU 09 60125 05/23/01 Co-58 -1. 15E+00 4 . 10E+00 1.50E+01 MU 09 60125 05/23/01 Co-60 -3. 81E+00 3. 74E+00 1.4 9E+01 MU 09 60125 05/23/01 Cr-51 -9. 88E+01 4 47E+01 1. 67E+02 MU 09 60125 05/23/01 Cs-134 3. 43E+00 4 50E+00 1.55E+01 MU 09 60125 05/23/01 Cs-137 0. 97E+00 4. 52E+00 1.58E+01 MU 09 60125 05/23/01 Fe-59 -1. 17E+01 1. 40E+01 5. 32E+01 MU 09 60125 05/23/01 1-131 3 48E+01 1. 54E+01 4. 92E+01 MU 09 60125 05/23/01 K-40 1. 36E+03 1. 13E+02 2.38E+02 MU 09 60125 05/23/01 Mn-54 1.47E+00 4. 06E+00 1. 43E+01 MU 09 60125 05/23/01 Ru-103 -6. 43E+00 5. 20E+00 1. 91E+01 MU 09 60125 05/23/01 Ru-106 -4. 62E+01 4.94E+01 1.78E+02 MU 09 60125 05/23/01 Sb-124 -3. 50E+00 1. 02E+01 3. 93E+01 MU 09 60125 05/23/01 Se-75 -4. 02E+00 4. 97E+00 1.77E+01 MU 09 60125 05/23/01 Zn-65 -1. 40E+01 1. 00E+01 3. 83E+01 MU 09 60125 05/23/01 Zr-95 3. 65E+00 8. 01E+00 2.80E+01 MU 09 63073 11/20/01 Th-232 3. 82E+01 3. 93E+01 1 . 37E+02 MU 09 63073 11/20/01 Ag-lIOM 4. 71E+00 1. 53E+01 5. 67E+01 MU 09 63073 11/20/01 Ba-140 6. 75E+00 2. 66E+01 1. 10E+02 MU 09 63073 11/20/01 Be-7 -6. 17E+01 1. 07E+02 4. 08E+02 MU 09 63073 11/20/01 Ce-141 3. 57E+01 2. 31E+01 7 .60E+01 MU 09 63073 11/20/01 Ce-144 -2. 63E+01 6.52E+01 2. 32E+02 MU 09 63073 11/20/01 Co-57 1.01E+01 7. 51E+00 2. 50E+01 MU 09 63073 11/20/01 Co-58 2. 30E+00 1. 06E+01 4. 01E+01 MU 09 63073 11/20/01 Co-60 2. 22E+01 1. 30E+01 4.17E+01 MU 09 63073 11/20/01 Cr-51 -3. 38E+01 1.36E+02 4. 96E+02 MU 09 63073 11/20/01 Cs-134 4. 34E+00 1. 19E+01 4. 36E+01 MU 09 63073 11/20/01 Cs-137 5. 52E+00 1. 09E+01 3. 92E+01 MU 09 63073 11/20/01 Fe-59 -8. 77E+00 2. 91E+01 1.24E+02 MU 09 63073 11/20/01 1-131 8. 11E+00 5. 93E+01 2. 15E+02 MU 09 63073 11/20/01 K-40 1.29E+03 2. 25E+02 4.72E+02 MU 09 63073 11/20/01 Mn-54 9. 91E+00 9. 74E+00 3. 39E+01 MU 09 63073 11/20/01 Ru-103 -2. 07E+00 1. 45E+01 5.37E+01 MU 09 63073 11/20/01 Ru-106 -1.58E+01 9. 10E+01 3. 47E+02 MU 09 63073 11/20/01 Sb-124 7.03E+00 2. 05E+01 8.59E+01 MU 09 63073 11/20/01 Se-75 -7. 97E+00 1.40E+01 5. 13E+01 MU 09 63073 11/20/01 Zn-65 -4. 95E+01 2. 55E+01 1. 12E+02 MU 09 63073 11/20/01 Zr-95 4. 01E+00 1.84E+01 6. 98E+01
- Concentration Greater than 3 Standard Deviations 49
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MUSSELS MU 59 60126 05/22/01 Th-232 4.45E+00 4. 03E+01 1. 60E+02 MU 59 60126 05/22/01 Ag-IIOM -8. 23E+00 1. 54E+01 6. 53E+01 MU 59 60126 05/22/01 Ba-140 -4.42E+01 1. 98E+01 1. 16E+02 MU 59 60126 05/22/01 Be-7 -1. 14E+02 8 51E+01 3.71E+02 MU 59 60126 05/22/01 Ce-141 3. 06E+01 1.57E+01 5. 03E+01 MU 59 60126 05/22/01 Ce-144 4.45E+01 5. 78E+01 1. 99E+02 MU 59 60126 05/22/01 Co-57 1.49E+00 6. 04E+00 2. 17E+01 MU 59 60126 05/22/01 Co-58 3. 81E+00 1.28E+01 4 .88E+01 MU 59 60126 05/22/01 Co-60 2. 60E+00 1. 16E+01 4. 79E+01 MU 59 60126 05/22/01 Cr-51 0. 00E+00 1. 00E+02 3. 76E+02 MU 59 60126 05/22/01 Cs-134 1. 60E+01 8. 10E+00 2. 15E+01 MU 59 60126 05/22/01 Cs-137 -2. 01E+01 1. 10E+01 5. 05E+01 MU 59 60126 05/22/01 Fe-59 -1. 71E+01 3. 23E+01 1. 47E+02 MU 59 60126 05/22/01 1-131 1. 49E+01 2. 67E+01 9. 64E+01 MU 59 60126 05/22/01 K-40 8. 34E+02 2. 56E+02 6. 88E+02
- MU 59 60126 05/22/01 Mn-54 5. 64E+00 9. 77E+00 3. 70E+01 MU 59 60126 05/22/01 Ru-103 -7. 35E+00 1. 17E+01 4 .77E+01 MU 59 60126 05/22/01 Ru-106 -2. 21E+01 1. 20E+02 4. 60E+02 MU 59 60126 05/22/01 Sb-124 0. 00E+00 2. 96E+01 1. 30E+02 MU 59 60126 05/22 /01 Se-75 1.29E+01 1. 18E+01 4. 03E+01 MU 59 60126 05/22/01 Zn-65 7. 23E+00 1. 91E+01 7 78E+01 MU 59 60126 05/22/01 Zr-95 -5. 87E+00 1. 68E+01 7 . 23E+01 MU 59 63074 11/20/01 Th-232 -2. 58E+01 2. 98E+01 2.63E+02 MU 59 63074 11/20/01 Ag-lIOM 1. 23E+01 1.33E+01 4. 64E+01 MU 59 63074 11/20/01 Ba-140 1. 91E+01 2.42E+01 9. OOE+01 MU 59 63074 11/20/01 Be-7 4. 09E+01 8. 07E+01 2.91E+02 MU 59 63074 11/20/01 Ce-141 4. 30E+00 1. 63E+01 5. 75E+01 MU 59 63074 11/20/01 Ce-144 6.76E+01 4. 54E+-01 1. 50E+02 MU 59 63074 11/2 0/01 Co-57 -4. 88E+00 5. 61E+00 2. 11E+01 MU 59 63074 11/20/01 Co-58 -1. 97E+00 6. 87E+00 2. 88E+01 MU 59 63074 11/20/01 Co-60 0. 86E+00 8. 08E+00 3. 24E+01 MU 59 63074 11/20/01 Cr-51 1. 98E+02 1. 06E+02 3. 40E+02 MU 59 63074 11/20/01 Cs-134 0 46E+00 7 58E+00 2. 98E+01 MU 59 63074 11/20/01 Cs-137 5. 84E+00 7.79E+00 2.79E+01 MU 59 63074 11/20/01 Fe-59 0. 91E+00 3. 00E+01 1. 18E+02 MU 59 63074 11/20/01 1-131 0. 00E+00 4 41E+01 1 . 65E+02 MU 59 63074 11/20/01 K-40 1. 14E+03 2. 09E+02 4.98E+02
- MU 59 63074 11/20/01 Mn-54 -3. 17E+00 8. 63E+00 3. 40E+01 MU 59 63074 11/20/01 Ru-103 -3. 29E+01 1. 23E+01 5. 27E+01 MU 59 63074 11/20/01 Ru-106 1. 15E+01 7. 99E+01 2 . 97E+02 MU 59 63074 11/20/01 Sb-124 0. 00E+00 2. 03E+01 8. 64E+01 MU 59 63074 11/20/01 Se-75 -1. 99E+00 1. 09E+01 3. 99E+01 MU 59 63074 11/20/01 Zn-65 -4.20E+01 2. 06E+01 9. 19E+01 MU 59 63074 11/20/01 Zr-95 1.26E+01 1. 68E+01 6. 03E+01
- Concentration Greater than 3 Standard Deviations 50
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 02 60140 05/21/01 Ag-11GM -7. 60E+01 2. 87E+01 1.26E+02 SE 02 60140 05/21/01 Ba-140 -2. 87E+01 2. 72E+02 9. 77E+02 SE 02 60140 05/21/01 Be-7 2. 02E+02 2. 29E+02 7.83E+02 SE 02 60140 05/21/01 Ce-141 1. 98E+01 5. 79E+01 1. 97E+02 SE 02 60140 05/21/01 Ce-144 -3. 10E+02 1. 49E+02 5. 41E+02 SE 02 60140 05/21/01 Co-57 0. 35E+00 2. 01E+01 6. 88E+01 SE 02 60140 05/21/01 Co-58 -1.89E+01 2. 21E+01 8. 81E+01 SE 02 60140 05/21/01 Co-60 7. 96E+00 2. 31E+01 8.55E+01 SE 02 60140 05/21/01 Cr-51 -4. 33E+02 3. 33E+02 1. 22E+03 SE 02 60140 05/21/01 Cs-134 8. 32E+00 2. 55E+01 8. 93E+01 SE 02 60140 05/21/01 Cs-137 -5. 03E+00 2. 51E+01 9. 18E+01 SE 02 60140 05/21/01 Fe-59 3.59E+01 8. 01E+01 2. 92E+02 SE 02 60140 05/21/01 1-131 -3.28E+02 1. 43E+02 5. 54E+02 SE 02 60140 05/21/01 K-40 1. 18E+04 7.85E+02 1.03E+03
- SE 02 60140 05/21/01 Mn-54 4. 27E+01 2.39E+01 7. 73E+01 SE 02 60140 05/21/01 Ru-103 0. OOE+00 2 .79E+01 1. 01E+02 SE 02 60140 05/21/01 Ru-106 -2. 55E+02 2.30E+02 8.74E+02 SE 02 60140 05/21/01 Sb-124 0. OOE+00 4. 99E+01 2. 03E+02 SE 02 60140 05/21/01 Se-75 2. 38E+00 3. 42E+01 1. 19E+02 SE 02 60140 05/21/01 Th-232 1. 90E+03 1.20E+02 2.89E+02
- SE 02 60140 05/21/01 Zn-65 -3. 62E+01 1. 12E+02 3. 95E+02 SE 02 60140 05/21/01 Zr-95 5. 74E+00 5.29E+01 1. 91E+02 SE 02 60141 05/21/01 Ag-IIOM -7 . 38E+00 2. 75E+01 1.07E+02 SE 02 60141 05/21/01 Ba-140 -2 48E+02 2.55E+02 9. 68E+02 SE 02 60141 05/21/01 Be-7 1. 06E+02 2. 31E+02 8. 11E+02 SE 02 60141 05/21/01 Ce-141 -7. 79E+01 4. 70E+01 1. 69E+02 SE 02 60141 05/21/01 Ce-144 1. 80E+01 1 . 37E+02 4. 69E+02 SE 02 60141 05/21/01 Co-57 -7 80E+00 1. 70E+01 5. 93E+01 SE 02 60141 05/21/01 Co-58 -1. 97E+01 2. 07E+01 8. 56E+01 SE 02 60141 05/21/01 Co-60 3. 94E+00 2. 61E+01 9. 87E+01 SE 02 60141 05/21/01 Cr-51 2. 32E+02 2. 69E+02 9. 18E+02 SE 02 60141 05/21/01 Cs-134 5. 31E+01 2. 20E+01 6. 83E+01 SE 02 60141 05/21/01 Cs-137 3. 65E+01 2 40E+01 7. 92E+01 SE 02 60141 05/21/01 Fe-59 2. 68E+01 8. 72E+01 3. 23E+02 SE 02 60141 05/21/01 1-131 -1. 34E+01 1. 20E+02 4. 32E+02 SE 02 60141 05/21/01 K-40 1. 14E+04 8 14E+02 9. 31E+02
- SE 02 60141 05/21/01 Mn-54 1. 80E+01 2 41E+01 8. 44E+01 SE 02 60141 05/21/01 Ru-103 2 49E+01 2. 78E+01 9. 57E+01 SE 02 60141 05/21/01 Ru-106 2. 19E+02 2. 09E+02 7 .12E+02 SE 02 60141 05/21/01 Sb-124 5. 10E+01 5. 10E+01 1. 83E+02 SE 02 60141 05/21/01 Se-75 -3. 90E+01 2. 92E+01 1. 08E+02 SE 02 60141 05/21/01 Th-232 1. 60E+03 1 .22E+02 2.87E+02
- SE 02 60141 05/21/01 Zn-65 -1. 64E+01 1. 10E+02 3. 89E+02 SE 02 60141 05/21/01 Zr-95 4. 76E+01 5. 29E+01 1. 83E+02
- Concentration Greater than 3 Standard Deviations 51
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 02 60142 05/21/01 Ag-11GM -4. 29E+01 2. 63E+01 1. 14E+02 SE 02 60142 05/21/01 Ba-140 3. 36E+02 2. 70E+02 9. 05E+02 SE 02 60142 05/21/01 Be-7 3. 27E+02 2. 18E+02 7.21E+02 SE 02 60142 05/21/01 Ce-141 1. 62E+01 4. 73E+01 1. 62E+02 SE 02 60142 05/21/01 Ce-144 -2. 17E+01 1.4 6E+02 5. 06E+02 SE 02 60142 05/21/01 Co-57 -8.80E+00 1.78E+01 6. 23E+01 SE 02 60142 05/21/01 Co-58 4.24E+01 2. 04E+01 6. 20E+01 SE 02 60142 05/21/01 Co-60 1. 66E+01 2. 36E+01 8. 57E+01 SE 02 60142 05/21/01 Cr-51 4. 56E+02 2 80E+02 9. 18E+02 SE 02 60142 05/21/01 Cs-134 -5. 76E+01 2 .30E+01 9. 35E+01 SE 02 60142 05/21/01 Cs-137 7 . 24E+00 2. 59E+01 9. 28E+01 SE 02 60142 05/21/01 Fe-59 -5. 42E+01 7. 58E+01 3. 14E+02 SE 02 60142 05/21/01 1-131 -7. 89E+00 1. 40E+02 4. 98E+02 SE 02 60142 05/2 1/01 K-40 1. 28E+04 8. 55E+02 8 .55E+02 SE 02 60142 05/21/01 Mn-54 -4. 04E+01 2. 52E+01 1. 02E+02 SE 02 60142 05/21/01 Ru-103 -1. 47E+01 2. 64E+01 1. OOE+02 SE 02 60142 05/21/01 Ru-106 -2 43E+02 2. 21E+02 8. 55E+02 SE 02 60142 05/21/01 Sb-124 1.71E+01 4. 52E+01 1.84E+02 SE 02 60142 05/21/01 Se-75 3. 95E+01 2. 84E+01 9. 42E+01 SE 02 60142 05/21/01 Th-232 9.08E+02 8. 82E+01 2.03E+02
- SE 02 60142 05/21/01 Zn-65 1. 19E+02 1. 17E+02 3. 93E+02 SE 02 60142 05/21/01 Zr-95 9.81E+01 4.89E+01 1.55E+02 SE 02 63134 11/19/01 Ag-11OM -2. 11E+00 2. 80E+01 1. 02E+02 SE 02 63134 11/19/01 Ba-140 4. 17E+01 9. 48E+01 3. 43E+02 SE 02 63134 11/19/01 Be-7 -3. 09E+02 2.06E+02 7. 76E+02 SE 02 63134 11/19/01 Ce-141 3. 13E+00 5. 62E+01 1. 91E+02 SE 02 63134 11/19/01 Ce-144 1. 15E+02 1. 36E+02 4. 56E+02 SE 02 63134 11/19/01 Co-57 2. 22E+01 1.70E+01 5. 65E+01 SE 02 63134 11/19/01 Co-58 -2. 54E+01 2. 24E+01 8. 63E+01 SE 02 63134 11/19/01 Co-60 -1. 91E+01 1.80E+01 7. 31E+01 SE 02 63134 11/19/01 Cr-51 1. 17E+02 2.84E+02 9. 78E+02 SE 02 63134 11/19/01 Cs-134 6. 24E+01 2. 13E+01 6. 37E+01 SE 02 63134 11/19/01 Cs-137 1. 90E+01 2. 05E+01 6. 99E+01 SE 02 63134 11/19/01 Fe-59 -1. 12E+02 7.23E+01 2. 95E+02 SE 02 63134 11/19/01 1-131 -1. 64E+02 1 . 88E+02 6. 88E+02 SE 02 63134 11/19/01 K-40 1.31E+04 6. 67E+02 6.41E+02
- SE 02 63134 11/19/01 Mn-54 3. 91E+01 1. 99E+01 6. 36E+01 SE 02 63134 11/19/01 Ru-103 2. 40E+01 2. 52E+01 8. 57E+01 SE 02 63134 11/19/01 Ru-106 -2.39E+02 1 . 57E+02 6. 09E+02 SE 02 63134 11/19/01 Sb-124 -1.74E+01 3. 81E+01 1. 63E+02 SE 02 63134 11/19/01 Se-75 2.88E+00 2. 64E+01 9. 12E+01 SE 02 63134 11/19/01 Th-232 9. 06E+02 8. 84E+01 3.16E+02
- SE 02 63134 11/19/01 Zn-65 1. 12E+02 1. 09E+02 3. 63E+02 SE 02 63134 11/19/01 Zr-95 -2. 96E+01 4. 36E+01 1. 62E+02
- Concentration Greater than 3 Standard Deviations 52
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 02 63135 11/19/01 Ag-11OM 3. 98E+00 2. 73E+01 9. 96E+01 SE 02 63135 11/19/01 Ba-140 -1. 70E+02 3. 10E+02 1. 14E+03 SE 02 63135 11/19/01 Be-7 1. 29E+02 2. 10E+02 7. 28E+02 SE 02 63135 11/19/01 Ce-141 -8. 27E+00 4. 24E+01 1. 47E+02 SE 02 63135 11/19/01 Ce-144 -7. 70E+01 1. 10E+02 3. 84E+02 SE 02 63135 11/19/01 Co-57 3. 43E+00 1. 32E+01 4. 51E+01 SE 02 63135 11/19/01 Co-58 -4. 66E+01 2. 33E+01 9. 57E+01 SE 02 63135 11/19/01 Co-60 1.27E+01 2. 36E+01 8. 47E+01 SE 02 63135 11/19/01 Cr-51 -1. 37E+02 2. 79E+02 9. 97E+02 SE 02 63135 11/19/01 Cs-134 2. 23E+01 1. 83E+01 6. 15E+01 SE 02 63135 11/19/01 Cs-137 -1. 57E+01 2. 12E+01 7. 91E+01 SE 02 63135 11/19/01 Fe-59 3. 24E+01 7. 88E+01 2.87E+02 SE 02 63135 11/19/01 1-131 1. 65E+02 2. 06E+02 7. 03E+02 SE 02 63135 11/19/01 K-40 1. 30E+04 7. 37E+02 6.92E+02 SE 02 63135 11/19/01 Mn-54 0. 00E+00 2. 29E+01 8.27E+01 SE 02 63135 11/19/01 Ru-103 -2. 98E+00 2.48E+01 9. 01E+01 SE 02 63135 11/19/01 Ru-106 1. 43E+02 1. 75E+02 6. 04E+02 SE 02 63135 11/19/01 Sb-124 1. 36E+01 4. 09E+01 1. 64E+02 SE 02 63135 11/19/01 Se-75 -7. 29E+00 2. 73E+01 9. 55E+01 SE 02 63135 11/19/01 Th-232 8 72E+02 8.82E+01 3.30E+02 SE 02 63135 11/19/01 Zn-65 1. 88E+02 1.11E+02 3. 65E+02 SE 02 63135 11/19/01 Zr-95 2. 15E+01 3. 62E+01 1.29E+02 SE 02 63136 11/19/01 Ag-IIOM 2. 60E+00 1. 93E+01 6. 98E+01 SE 02 63136 11/19/01 Ba-140 1. 90E+02 2.44E+02 8. 39E+02 SE 02 63136 11/19/01 Be-7 7. 94E+01 1. 38E+02 4.80E+02 SE 02 63136 11/19/01 Ce-141 -1. 89E+01 3. 45E+01 1.21E+02 SE 02 63136 11/19/01 Ce-144 7. 36E+01 8. 94E+01 3. 01E+02 SE 02 63136 11/19/01 Co-57 -1. OOE+00 1. 10E+01 3. 80E+01 SE 02 63136 11/19/01 Co-58 -2. 53E+01 1.56E+01 6. 31E+01 SE 02 63136 11/19/01 Co-60 -1. 60E+01 1. 60E+01 6. 29E+01 SE 02 63136 11/19/01 Cr-51 2. 22E+02 2. 16E+02 7. 29E+02 SE 02 63136 11/19/01 Cs-134 -5. 94E+00 1.31E+01 4.79E+01 SE 02 63136 11/19/01 Cs-137 -3. 82E+00 1. 45E+01 5. 28E+01 SE 02 63136 11/19/01 Fe-59 -1. 06E+02 6. 01E+01 2.45E+02 SE 02 63136 11/19/01 1-131 -3. 50E+01 1. 90E+02 6. 78E+02 SE 02 63136 11/19/01 K-40 1. 58E+04 6. 29E+02 5.75E+02 SE 02 63136 11/19/01 Mn-54 -2. 62E+01 1.31E+01 5. 33E+01 SE 02 63136 11/19/01 Ru-103 -5. 67E+00 1. 94E+01 7. 08E+01 SE 02 63136 11/19/01 Ru-106 2. 64E+01 1. 16E+02 4.15E+02 SE 02 63136 11/19/01 Sb-124 -2.48E+01 3. 20E+01 1. 38E+02 SE 02 63136 11/19/01 Se-75 -1. 47E+01 1. 68E+01 6. 11E+01 SE 02 63136 11/19/01 Th-232 6. 42E+02 6. 37E+01 1.99E+02 SE 02 63136 11/19/01 Zn-65 2. 26E+02 7.86E+01 2.4 9E+02 SE 02 63136 11/19/01 Zr-95 5. 24E+01 3.26E+01 1. 07E+02
- Concentration Greater than 3 Standard Deviations 53
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 07 60146 05/23/01 Ag-110M -1. 76E+01 1. 93E+01 8. 11E+01 SE 07 60146 05/23/01 Ba-140 1. 52E+02 1. 73E+02 5. 98E+02 SE 07 60146 05/23/01 Be-7 -2. 25E+02 1.4 6E+02 5. 94E+02 SE 07 60146 05/23/01 Ce-141 1.7 9E+01 2. 87E+01 9. 88E+01 SE 07 60146 05/23/01 Ce-144 -3. 87E+01 8.57E+01 3. 08E+02 SE 07 60146 05/23/01 Co-57 2. 65E+00 1. 17E+01 4 .08E+01 SE 07 60146 05/23/01 Co-58 -5. 05E+00 1.44E+01 5. 83E+01 SE 07 60146 05/23/01 Co-60 1. 69E+01 1.87E+01 6. 61E+01 SE 07 60146 05/23/01 Cr-51 1. 57E+02 1.81E+02 6. 23E+02 SE 07 60146 05/23/01 Cs-134 1. 35E+01 2.50E+01 8.42E+01 SE 07 60146 05/23/01 Cs-137 3. 17E+00 1. 80E+01 6. 59E+01 SE 07 60146 05/23/01 Fe-59 -5. 73E+01 6. 26E+01 2. 59E+02 SE 07 60146 05/23/01 1-131 -3. 30E+01 7.21E+01 2. 75E+02 SE 07 60146 05/23/01 K-40 1. 72E+04 8. 55E+02 6.38E+02
- SE 07 60146 05/23/01 Mn-54 -2. 81E+01 1. 36E+01 6. 15E+01 SE 07 60146 05/23/01 Ru-103 0. OOE+00 1. 80E+01 6. 72E+01 SE 07 60146 05/23/01 Ru-106 -1. 21E+02 1 .23E+02 5. 03E+02 SE 07 60146 05/23/01 Sb-124 -3. 85E+01 2 87E+01 1. 54E+02 SE 07 60146 05/23/01 Se-75 -6. 38E+00 2. O1E+01 7. 29E+01 SE 07 60146 05/23/01 Th-232 3. 88E+02 7. 67E+01 2.82E+02
- SE 07 60146 05/23/01 Zn-65 7. 36E+00 4. 60E+01 1. 69E+02 SE 07 60146 05/23/01 Zr-95 -1.54E+01 3. 13E+01 1. 23E+02 SE 07 60147 05/23/01 Ag-lIOM 2. 88E+00 2. 68E+01 1. OOE+02 SE 07 60147 05/23/01 Ba-140 -4.42E+01 1. 65E+02 6. 26E+02 SE 07 60147 05/23/01 Be-7 2. 39E+01 1. 41E+02 5. 23E+02 SE 07 60147 05/23/01 Ce-141 -7. 01E+00 2. 81E+01 1. OOE+02 SE 07 60147 05/23/01 Ce-144 -1. 11E+01 8. 31E+01 2. 94E+02 SE 07 60147 05/23/01 Co-57 9.18E+00 1. 09E+01 3. 70E+01 SE 07 60147 05/23/01 Co-58 2.35E+00 1. 76E+01 6. 74E+01 SE 07 60147 05/23/01 Co-60 7. 79E+00 1. 42E+01 5. 52E+01 SE 07 60147 05/23/01 Cr-51 4 .61E+01 1. 81E+02 6. 50E+02 SE 07 60147 05/23/01 Cs-134 1.71E+01 1. 49E+01 5. 08E+01 SE 07 60147 05/23/01 Cs-137 2. 68E+01 1. 87E+01 6. 21E+01 SE 07 60147 05/23/01 Fe-59 -2. 23E+01 7 76E+01 3. 02E+02 SE 07 60147 05/23/01 1-131 6. 85E+01 8. 39E+01 2. 91E+02 SE 07 60147 05/23/01 K-40 1.81E+04 9. 45E+02 5. 37E+02
- SE 07 60147 05/23/01 Mn-54 -3. 27E+00 1. 43E+01 5. 70E+01 SE 07 60147 05/23/01 Ru-103 0. OOE+00 1. 75E+01 6. 63E+01 SE 07 60147 05/23/01 Ru-106 -8.4 8E+00 1. 51E+02 5. 67E+02 SE 07 60147 05/23/01 Sb-124 -1.54E+01 4. 06E+01 1. 84E+02 SE 07 60147 05/23/01 Se-75 9. 67E+00 1. 91E+01 6. 70E+01 SE 07 60147 05/23/01 Th-232 1. 22E+02 1. 40E+02 4 .57E+02 SE 07 60147 05/23/01 Zn-65 1. 20E+02 8 .23E+01 2. 73E+02 SE 07 60147 05/23/01 Zr-95 -1.30E+01 3. 20E+01 1. 27E+02
- Concentration Greater than 3 Standard Deviations 54
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 07 60148 05/23/01 Ag-IIOM -5. 37E+01 2. 44E+01 1. 10E+02 SE 07 60148 05/23/01 Ba-140 -1. 38E+02 1. 74E+02 6. 81E+02 SE 07 60148 05/23/01 Be-7 1. 48E+02 1. 52E+02 5. 24E+02 SE 07 60148 05/23/01 Ce-141 -2. 33E+01 3. 11E+01 1. 13E+02 SE 07 60148 05/23/01 Ce-144 8. 95E+01 9. 39E+01 3. 18E+02 SE 07 60148 05/23/01 Co-57 1.46E+01 1. 13E+01 3. 77E+01 SE 07 60148 05/23/01 Co-58 -1. 63E+01 1. 66E+01 7.08E+01 SE 07 60148 05/23/01 Co-60 3. 14E+01 1. 94E+01 6. 23E+01 SE 07 60148 05/23/01 Cr-51 2.87E+02 1. 66E+02 5 . 37E+02 SE 07 60148 05/23/01 Cs-134 -1. 67E+00 2. 56E+01 9. 13E+01 SE 07 60148 05/23/01 Cs-137 -1. 47E+01 1.88E+01 7. 39E+01 SE 07 60148 05/23/01 Fe-59 -2. 07E+01 7. 50E+01 2. 94E+02 SE 07 60148 05/23/01 1-131 -1.85E+01 6. 84E+01 2. 62E+02 SE 07 60148 05/23/01 K-40 1. 87E+04 9.78E+02 8. 30E+02
- SE 07 60148 05/23/01 Mn-54 -6. 80E+00 1. 84E+01 7.15E+01 SE 07 60148 05/23/01 Ru-103 -2.30E+01 1. 77E+01 7. 39E+01 SE 07 60148 05/23/01 Ru-106 -6. 51E+01 1. 55E+02 5. 98E+02 SE 07 60148 05/23/01 Sb-124 3. 09E+01 3. 09E+01 1. 14E+02 SE 07 60148 05/23/01 Se-75 0. 00E+00 2. 10E+01 7. 53E+01 SE 07 60148 05/23/01 Th-232 3. 79E+02 7. 18E+01 2. 56E+02 SE 07 60148 05/23/01 Zn-65 7.72E+01 5. 22E+01 1. 73E+02 SE 07 60148 05/23/01 Zr-95 -3. 98E+01 2. 98E+01 1. 30E+02 SE 07 63140 11/20/01 Ag-IIOM -7 86E+00 2. 44E+01 9. 01E+01 SE 07 63140 11/20/01 Ba-140 2. 62E+02 2. 35E+02 7. 96E+02 SE 07 63140 11/20/01 Be-7 1. 75E+02 1.4 4E+02 4 .86E+02 SE 07 63140 11/20/01 Ce-141 -2. 96E+01 4 .12E+01 1. 44E+02 SE 07 63140 11/20 /01 Ce-144 -2. 80E+01 1. OOE+02 3. 4 6E+02 SE 07 63140 11/20 /01 Co-57 -3. 93E+00 1.29E+01 4.4 6E+01 SE 07 63140 11/20 /01 Co-58 -2. 03E+01 1. 90E+01 7. 37E+01 SE 07 63140 11/20/01 Co-60 8 .4 1E+00 1.51E+01 5. 4 6E+01 SE 07 63140 11/20/01 Cr-51 3. 75E+02 2. 21E+02 7. 23E+02 SE 07 63140 11/2 0/01 Cs-134 -1. 48E+02 1. 94E+01 8. 53E+01 SE 07 63140 11/20/01 Cs-137 -5. 57E+00 1. 45E+01 5. 39E+01 SE 07 63140 11/20/01 Fe-59 0. 00E+00 7. 05E+01 2. 60E+02 SE 07 63140 11/20/01 1-131 -1. 80E+02 1.75E+02 6. 55E+02 SE 07 63140 11/20/01 K-40 1. 86E+04 7.42E+02 6.59E+02 SE 07 63140 11/20/01 Mn-54 1. 30E+01 1.53E+01 5. 30E+01 SE 07 63140 11/20/01 Ru-103 -4 89E+00 2. 24E+01 8. 12E+01 SE 07 63140 11/20/01 Ru-106 4 87E+01 1.29E+02 4 .58E+02 SE 07 63140 11/20/01 Sb-124 6. 89E+00 2.72E+01 1. 12E+02 SE 07 63140 11/20/01 Se-75 -2. 57E+01 2. 04E+01 7. 44E+01 SE 07 63140 11/20/01 Th-232 3. 64E+02 6. 89E+01 2.50E+02 SE 07 63140 11/20/01 Zn-65 5.71E+00 8. 32E+01 2. 87E+02 SE 07 63140 11/20/01 Zr-95 -1.34E+01 2.99E+01 1. 14E+02
- Concentration Greater than 3 Standard Deviations 55
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 07 63141 11/20/01 Ag-IIOM -3. 08E+01 1. 90E+01 8.04E+01 SE 07 63141 11/20/01 Ba-140 1. 17E+01 1. 77E+02 6. 65E+02 SE 07 63141 11/20/01 Be-7 7. 55E+01 1. 39E+02 4. 90E+02 SE 07 63141 11/20/01 Ce-141 9. 10E+00 2. 86E+01 9. 85E+01 SE 07 63141 11/20/01 Ce-144 -2. 29E+01 6. 71E+01 2. 37E+02 SE 07 63141 11/20/01 Co-57 -7 .25E+00 8. 59E+00 3. 08E+01 SE 07 63141 11/20/01 Co-58 2. 34E+01 1 38E+01 4. 41E+01 SE 07 63141 11/20/01 Co-60 1. 41E+01 1 44E+01 5. 05E+01 SE 07 63141 11/20/01 Cr-51 -6. 16E+01 1. 96E+02 7 .11E+02 SE 07 63141 11/20/01 Cs-134 5. 11E+00 1 19E+01 4. 24E+01 SE 07 63141 11/20/01 Cs-137 2. 17E+01 1 44E+01 4. 74E+01 SE 07 63141 11/20/01 Fe-59 -4 67E+01 6.81E+01 2 70E+02 SE 07 63141 11/20/01 1-131 1. 14E+02 1. 81E+02 6.28E+02 SE 07 63141 11/20/01 K-40 1. 51E+04 7 .17E+02 4. 28E+02
- SE 07 63141 11/20/01 Mn-54 6. 95E+00 1. 37E+01 4. 94E+01 SE 07 63141 11/20/01 Ru-103 5.29E+00 1. 50E+01 5. 4 9E+01 SE 07 63141 11/20/01 Ru-106 -1.26E+02 1. 11E+02 4. 47E+02 SE 07 63141 11/20/01 Sb-124 -1.19E+01 1.19E+01 8.79E+01 SE 07 63141 11/20/01 Se-75 1. 10E+01 1. 55E+01 5.35E+01 SE 07 63141 11/20/01 Th-232 3.25E+02 6. 34E+01 2. 14E+02 SE 07 63141 11/20//01 Zn-65 1. 39E+01 7. 36E+01 2. 57E+02 SE 07 63141 11/20/01 Zr-95 1.69E+01 2. 95E+01 1. 06E+02 SE 07 63142 11/20/01 Ag-IIOM -1. 94E+01 2. 23E+01 8. 93E+01 SE 07 63142 11/20/01 Ba-140 2 . 25E+02 2. 56E+02 8. 85E+02 SE 07 63142 11/20 /01 Be-7 2. 17E+01 1. 61E+02 5 .835+02 SE 07 63142 11/20 /01 Ce-141 1. 60E+01 3. 43E+01 1. 18E+02 SE 07 63142 11/20 /01 Ce-144 -1. 34E+02 8. 24E+01 3. 03E+02 SE 07 63142 11/20 /01 Co-57 -3. 56E+00 1 .00E+01 3. 55E+01 SE 07 63142 11/20 /01 Co-58 2 .8 6E+00 1.65E+01 6. 23E+01 SE 07 63142 11/20 /01 Co-60 2. 30E+01 1.79E+01 6. 07E+01 SE 07 63142 11/20/01 Cr-51 7. 15E+01 2.20E+02 7 75E+02 SE 07 63142 11/20/01 Cs-134 -5. 86E+00 1. 48E+01 5. 53E+01 SE 07 63142 11/20/01 Cs-137 3. 34E+01 1. 53E+01 4 73E+01 SE 07 63142 11/20/01 Fe-59 -4. 76E+01 6. 82E+01 2 76E+02 SE 07 63142 11/20/01 1-131 -1. 53E+02 1. 77E+02 6. 70E+02 SE 07 63142 11/20/01 K-40 1. 59E+04 7. 93E+02 6. 81E+02
- SE 07 63142 11/20/01 Mn-54 2. 11E+01 1. 62E+01 5. 4 6E+01 SE 07 63142 11/20/01 Ru-103 1. 52E+01 1. 95E+01 6. 83E+01 SE 07 63142 11/20/01 Ru-106 -2 .74E+01 1. 44E+02 5. 36E+02 SE 07 63142 11/20/01 Sb-124 -1. 34E+01 3. 55E+01 1. 61E+02 SE 07 63142 11/20/01 Se-75 2.02E+01 2. 06E+01 6. 96E+01 SE 07 63142 11/20/01 Th-232 3. 59E+02 6. 17E+01 2. 59E+02
- SE 07 63142 11/20/01 Zn-65 -8. 88E+01 4.78E+01 1. 96E+02 SE 07 63142 11/20/01 Zr-95 7 87E+00 3.26E+01 1. 21E+02
- Concentration Greater than 3 Standard Deviations 56
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 08 60149 05/23/01 Ag-liOM 3. 22E+00 1. 90E+01 7. 04E+01 SE 08 60149 05/23/01 Ba-140 6.42E+01 1. 48E+02 5. 25E+02 SE 08 60149 05/23/01 Be-7 -2. 66E+02 1. 21E+02 5. 07E+02 SE 08 60149 05/23/01 Ce-141 -7. 4 6E+00 2 .79E+01 9. 89E+01 SE 08 60149 05/23/01 Ce-144 5 40E+01 8. 26E+01 2. 83E+02 SE 08 60149 05/23/01 Co-57 1.21E+01 1. 02E+01 3. 40E+01 SE 08 60149 05/23/01 Co-58 -1 . 32E+01 1. 72E+01 6. 66E+01 SE 08 60149 05/23/01 Co-60 -1. 1IE+01 1. 29E+01 5. 47E+01 SE 08 60149 05/23/01 Cr-51 4 . OOE+02 1. 76E+02 5. 57E+02 SE 08 60149 05/23/01 Cs-134 -1. 04E+01 1. 29E+01 4. 93E+01 SE 08 60149 05/23/01 Cs-137 -1. O1E+01 1. 53E+01 5. 82E+01 SE 08 60149 05/23/01 Fe-59 9. 45E+01 5. 03E+01 1.59E+02 SE 08 60149 05/23/01 1-131 -9. 12E+01 8. 01E+01 3. 04E+02 SE 08 60149 05/23/01 K-40 1. 99E+04 7. 88E+02 6.37E+02
- SE 08 60149 05/23/01 Mn-54 8.85E+00 1. 66E+01 5.85E+01 SE 08 60149 05/23/01 Ru-103 1. 41E+01 1. 63E+01 5. 66E+01 SE 08 60149 05/23/01 Ru-106 -1. 81E+01 1. 20E+02 4. 50E+02 SE 08 60149 05/23/01 Sb-124 -7. 27E+00 1. 99E+01 9. 59E+01 SE 08 60149 05/23/01 Se-75 -1.75E+00 1.87E+01 6. 66E+01 SE 08 60149 05/23/01 Th-232 2. 09E+02 7. 48E+01 2.27E+02 SE 08 60149 05/23/01 Zn-65 -7. 65E+01 4.32E+01 1. 72E+02 SE 08 60149 05/23/01 Zr-95 2. 62E+01 2. 95E+01 1. 02E+02 SE 08 60150 05/23/01 Ag-IlOM -1. 03E+01 2.OOE+01 7. 63E+01 SE 08 60150 05/23/01 Ba-140 -1. 22E+01 1.22E+02 4. 52E+02 SE 08 60150 05/23/01 Be-7 -4 .87E+01 1.20E+02 4. 51E+02 SE 08 60150 05/23/01 Ce-141 0. 11E+00 2.52E+01 8.82E+01 SE 08 60150 05/23/01 Ce-144 -1. 01E+00 7.71E+01 2. 70E+02 SE 08 60150 05/23/01 Co-57 -6. 90E+00 9. 85E+00 3. 54E+01 SE 08 60150 05/23/01 Co-58 -2. 03E+01 1. 41E+01 5. 80E+01 SE 08 60150 05/23/01 Co-60 -0. 69E+00 1.35E+01 5. 22E+01 SE 08 60150 05/23/01 Cr-51 1. 50E+02 1. 53E+02 5. 22E+02 SE 08 60150 05/23/01 Cs-134 7. 18E+00 1.24E+01 4. 37E+01 SE 08 60150 05/23/01 Cs-137 2. 50E+01 1.27E+01 4. 01E+01 SE 08 60150 05/23/01 Fe-59 8. 13E+01 6. 17E+01 2 . 07E+02 SE 08 60150 05/23/01 1-131 -1. 54E+02 6. 31E+01 2. 60E+02 SE 08 60150 05/23/01 K-40 2. 17E+04 7 86E+02 4.91E+02
- SE 08 60150 05/23/01 Mn-54 1. 28E+01 1. 22E+01 4. 20E+01 SE 08 60150 05/23/01 Ru-103 -2. 81E+01 1. 54E+01 6. 27E+01 SE 08 60150 05/23/01 Ru-106 -1. 96E+01 1. 12E+02 4. 19E+02 SE 08 60150 05/23/01 Sb-124 -8. 58E+00 1. 49E+01 7. 97E+01 SE 08 60150 05/23/01 Se-75 -2. 23E+01 1. 69E+01 6. 33E+01 SE 08 60150 05/23/01 Th-232 2. 15E+02 7. 96E+01 2. 47E+02 SE 08 60150 05/23/01 Zn-65 -1. 37E+02 4 14E+01 1. 75E+02 SE 08 60150 05/23/01 Zr-95 -1. 18E+01 2. 54E+01 9. 78E+01
- Concentration Greater than 3 Standard Deviations 57
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 08 60151 05/23/01 Ag-IIOM 1. 64E+01 1. 56E+01 5.4 9E+01 SE 08 60151 05/23/01 Ba-140 2. 10E+02 1. 62E+02 5. 4 6E+02 SE 08 60151 05/23/01 Be-7 2. 39E+01 1. 45E+02 5. 36E+02 SE 08 60151 05/23/01 Ce-141 3. 63E+00 3. 13E+01 1. 10E+02 SE 08 60151 05/23/01 Ce-144 -9. 95E+01 8 .73E+01 3. 23E+02 SE 08 60151 05/23/01 Co-57 -6. 29E+00 1. 13E+01 4. 06E+01 SE 08 60151 05/23/01 Co-58 5. 81E+00 1.71E+01 6.4 OE+01 SE 08 60151 05/23/01 Co-60 0. OOE+00 1. 90E+01 7 .4 3E+01 SE 08 60151 05/23/01 Cr-51 -9. 54E+01 1. 88E+02 7. 02E+02 SE 08 60151 05/23/01 Cs-134 -1.75E+01 2. 20E+01 8.47E+01 SE 08 60151 05/23/01 Cs-137 -1. 01E+01 1. 69E+01 6. 62E+01 SE 08 60151 05/23/01 Fe-59 0. OOE+00 5. 92E+01 2 . 31E+02 SE 08 60151 05/23/01 1-131 3. 51E+01 8.83E+01 3. 14E+02 SE 08 60151 05/23/01 K-40 1. 81E+04 8.94E+02 5 . 04E+02
- SE 08 60151 05/23/01 Mn-54 -1. 55E+01 1.43E+01 6. 06E+01 SE 08 60151 05/23/01 Ru-103 -1. 27E+01 1. 68E+01 6. 78E+01 SE 08 60151 05/23/01 Ru-106 -2. 48E+01 1. 65E+02 6. 17E+02 SE 08 60151 05/23/01 Sb-124 -2. 72E+01 3. 85E+01 1 .79E+02 SE 08 60151 05/23/01 Se-75 -2. 94E+01 2. 06E+01 7. 89E+01 SE 08 60151 05/23/01 Th-232 2. 01E+02 7 .40E+01 2. 72E+02 SE 08 60151 05/23/01 Zn-65 -1.4 1E+02 5. 41E+01 2. 30E+02 SE 08 60151 05/23/01 Zr-95 2. 4 9E+01 3. 42E+01 1. 22E+02 SE 08 63143 11/20/01 Ag-IIOM -2. 56E+01 1.56E+01 6. 36E+01 SE 08 63143 11/20/01 Ba-140 -6. 65E+01 2. 17E+02 7. 90E+02 SE 08 63143 11/20/01 Be-7 -7. 11E+01 1.25E+02 4. 62E+02 SE 08 63143 11/20/01 Ce-141 -6. 73E+00 3. 03E+01 1. 06E+02 SE 08 63143 11/20/01 Ce-144 1. 67E+01 7.20E+01 2. 48E+02 SE 08 63143 11/20/01 Co-57 3. 14E+00 9. 50E+00 3. 26E+01 SE 08 63143 11/20/01 Co-58 -2. 19E+01 1 50E+01 5. 93E+01 SE 08 63143 11/20/01 Co-60 1. 27E+00 1. 12E+01 4. 22E+01 SE 08 63143 11/20/01 Cr-51 -1. 16E+02 1. 81E+02 6. 59E+02 SE 08 63143 11/20/01 Cs-134 1. 24E+00 1. 08E+01 3. 88E+01 SE 08 63143 11/20/01 Cs-137 -1. 15E+01 1. 19E+01 4. 55E+01 SE 08 63143 11/20/01 Fe-59 -1. 54E+00 5. 32E+01 1. 96E+02 SE 08 63143 11/20/01 1-131 7 44E+01 1. 50E+02 5. 20E+02 SE 08 63143 11/20/01 K-40 1 . 72E+04 6. 11E+02 4 .1E+02
- SE 08 63143 11/20/01 Mn-54 -1. 59E+01 1. 27E+01 4. 94E+01 SE 08 63143 11/20/01 Ru-103 -9. 91E+00 1. 60E+01 5. 99E+01 SE 08 63143 11/20/01 Ru-106 1.30E+01 1. 14E+02 4. 06E+02 SE 08 63143 11/20/01 Sb-124 2. 70E+01 2. 38E+01 8. 31E+01 SE 08 63143 11/20/01 Se-75 1. 30E+00 1. 67E+01 5 84E+01 SE 08 63143 11/20/01 Th-232 2 .26E+02 5. 27E+01 1 .84E+02
- SE 08 63143 11/20/01 Zn-65 1. 05E+02 6. 09E+01 1. 99E+02 SE 08 63143 11/20/01 Zr-95 4.30E+01 2. 60E+01 8.49E+01
- Concentration Greater than 3 Standard Deviations 58
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 08 63144 11/20/01 Ag-IlOM -1. 01E+01 1. 65E+01 6. 18E+01 SE 08 63144 11/20/01 Ba-140 -8. 11E+01 1. 72E+02 6. 36E+02 SE 08 63144 11/20/01 Be-7 2. 45E+01 1. 14E+02 4. 03E+02 SE 08 63144 11/20/01 Ce-141 -3.70E+01 2. 50E+01 9. 06E+01 SE 08 63144 11/20/01 Ce-144 -1. 50E+01 6. 43E+01 2. 24E+02 SE 08 63144 11/20/01 Co-57 9. 54E+00 8.53E+00 2. 85E+01 SE 08 63144 11/20/01 Co-58 -2. 80E+00 1.29E+01 4 .76E+01 SE 08 63144 11/20/01 Co-60 -9. 22E+00 1.34E+01 5. 10E+01 SE 08 63144 11/20/01 Cr-51 -1 . 42E+02 1. 69E+02 6. 13E+02 SE 08 63144 11/20/01 Cs-134 1.37E+01 9. 31E+00 3. 08E+01 SE 08 63144 11/20/01 Cs-137 6. 16E+00 1. 05E+01 3. 68E+01 SE 08 63144 11/20/01 Fe-59 -2.35E+01 5. 35E+01 1. 99E+02 SE 08 63144 11/20/01 1-131 -1.41E+02 1.25E+02 4 .68E+02 SE 08 63144 11/20/01 K-40 2. 24E+04 6. 48E+02 3. 65E+02 SE 08 63144 11/20/01 Mn-54 8 .28E+00 1. 06E+01 3. 66E+01 SE 08 63144 11/20/01 Ru-103 0. 77E+00 1. 31E+01 4. 77E+01 SE 08 63144 11/20/01 Ru-106 7. 65E+01 9. 36E+01 3. 23E+02 SE 08 63144 11/20/01 Sb-124 -3. 19E+01 1. 69E+01 9. OOE+01 SE 08 63144 11/20/01 Se-75 -1. 68E+01 1. 28E+01 4. 76E+01 SE 08 63144 11/20/01 Th-232 2. 58E+02 4. 58E+01 1 .77E+02
- SE 08 63144 11/20/01 Zn-65 5. 72E+01 6. 05E+01 2. 03E+02 SE 08 63144 11/20/01 Zr-95 2. 13E+01 2. 50E+01 8. 60E+01 SE 08 63145 11/20/01 Ag-IIOM 2 . 34E+00 2. 47E+01 8. 93E+01 SE 08 63145 11/20/01 Ba-140 -5. 95E+02 2. 99E+02 1. 19E+03 SE 08 63145 11/20/01 Be-7 2 44E+02 1. 88E+02 6.29E+02 SE 08 63145 11/20/01 Ce-141 -4 16E+01 4 75E+01 1. 66E+02 SE 08 63145 11/20/01 Ce-144 7 91E+01 1. 09E+02 3. 68E+02 SE 08 63145 11/20/01 Co-57 -1. 48E+00 1. 36E+01 4. 66E+01 SE 08 63145 11/20/01 Co-58 -5. 39E+00 2. 19E+01 8. 04E+01 SE 08 63145 11/20/01 Co-60 -1. 16E+01 1. 79E+01 6. 97E+01 SE 08 63145 11/20/01 Cr-51 2. 30E+02 2. 58E+02 8 .76E+02 SE 08 63145 11/20/01 Cs-134 -3. 27E+02 2. 64E+01 1. 19E+02 SE 08 63145 11/20/01 Cs-137 -2 49E+01 1. 64E+01 6. 37E+01 SE 08 63145 11/20/01 Fe-59 -6. 59E+01 7. 92E+01 3. 05E+02 SE 08 63145 11/20/01 1-131 4 75E+02 2. 37E+02 7. 60E+02 SE 08 63145 11/20/01 K-40 2 . 21E+04 8. 18E+02 6. 34E+02 *k SE 08 63145 11/20/01 Mn-54 -9. 01E+00 1. 86E+01 6. 86E+01 SE 08 63145 11/20/01 Ru-103 -3. 98E+01 2. 14E+01 8. 53E+01 SE 08 63145 11/20/01 Ru-106 -1. 18E+02 1 55E+02 5. 78E+02 SE 08 63145 11/20/01 Sb-124 8 40E+00 2 44E+01 1. 03E+02 SE 08 63145 11/20/01 Se-75 -2. 61E+01 2. 28E+01 8.24E+01 SE 08 63145 11/20/01 Th-232 2. 73E+02 9. 57E+01 2. 97E+02 SE 08 63145 11/20/01 Zn-65 1. 19E+02 9. 74E+01 3.24E+02 SE 08 63145 11/20/01 Zr-95 3. 80E+01 4 08E+01 1. 40E+02
- Concentration Greater than 3 Standard Deviations 59
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 52 60143 05/21/01 Ag-IIOM 1. 13E+01 2.75E+01 1 OOE+02 SE 52 60143 05/21/01 Ba-140 -3. 8 6E+01 2. 82E+02 1. 01E+03 SE 52 60143 05/21/01 Be-7 -2. 53E+02 2. 77E+02 1. 02E+03 SE 52 60143 05/21/01 Ce-141 7. 22E+01 6. 19E+01 2. 06E+02 SE 52 60143 05/21/01 Ce-144 -1. 53E+02 1.78E+02 6. 21E+02 SE 52 60143 05/21/01 Co-57 -1. 96E+01 2. 28E+01 7. 93E+01 SE 52 60143 05/21/01 Co-58 -2. 4 6E+01 2. 74E+01 1. 06E+02 SE 52 60143 05/21/01 Co-60 2 84E+00 2. 36E+01 8. 91E+01 SE 52 60143 05/21/01 Cr-51 -7 68E+01 3. 59E+02 1. 26E+03 SE 52 60143 05/21/01 Cs-134 -5. 33E+01 2. 37E+01 9. 34E+01 SE 52 60143 05/21/01 Cs-137 -5. 59E+01 3. 17E+01 1. 21E+02 SE 52 60143 05/21/01 Fe-59 5. 03E+01 8. 16E+01 2. 92E+02 SE 52 60143 05/2 1/01 1-131 -6. 66E+01 1. 44E+02 5. 20E+02 SE 52 60143 05/21/01 K-40 1. 13E+04 7 70E+02 1. 03E+03
- SE 52 60143 05/21/01 Mn-54 0. 81E+00 2 43E+01 8. 87E+01 SE 52 60143 05/21/01 Ru-103 -6. 78E+01 3. 39E+01 1. 31E+02 SE 52 60143 05/21/01 Ru-106 -1. 47E+02 2. 33E+02 8. 63E+02 SE 52 60143 05/21/01 Sb-124 -7.21E+01 4. 78E+01 2 .29E+02 SE 52 60143 05/21/01 Se-75 -3. 81E+01 3. 89E+01 1. 38E+02 SE 52 60143 05/21/01 Th-232 2.75E+03 1.29E+02 3.57E+02
- SE 52 60143 05/21/01 Zn-65 2. 97E+02 1. 18E+02 3.7 6E+02 SE 52 60143 05/21/01 Zr-95 6. 25E+01 5. 94E+01 2. 02E+02 SE 52 60144 05/21/01 Ag-iIOM -2. 16E+00 3.43E+01 1. 28E+02 SE 52 60144 05/21/01 Ba-140 1. 42E+02 2. 68E+02 9. 39E+02 SE 52 60144 05/21/01 Be-7 -1. 36E+02 2. 19E+02 8. 22E+02 SE 52 60144 05/21/01 Ce-141 -1.04E+01 5. 01E+01 1. 73E+02 SE 52 60144 05/21/01 Ce-144 9. 38E+01 1.37E+02 4. 62E+02 SE 52 60144 05/21/01 Co-57 -9. 66E+00 1. 82E+01 6. 36E+01 SE 52 60144 05/21/01 Co-58 1. 07E+00 2.33E+01 8.78E+01 SE 52 60144 05/21/01 Co-60 1. 55E+01 2. 66E+01 9. 67E+01 SE 52 60144 05/21/01 Cr-51 3.45E+02 2 . 97E+02 9. 96E+02 SE 52 60144 05/21/01 Cs-134 -2. 29E+01 2. 34E+01 8. 86E+01 SE 52 60144 05/21/01 Cs-137 -3. 46E+01 2.49E+01 9. 83E+01 SE 52 60144 05/21/01 Fe-59 6.36E+01 8. 92E+01 3. 19E+02 SE 52 60144 05/21/01 1-131 0. OOE+00 1. 41E+02 5. 02E+02 SE 52 60144 05/21/01 K-40 1. 19E+04 8. 41E+02 9.55E+02
- SE 52 60144 05/21/01 Mn-54 3. 68E+00 2. 73E+01 9. 90E+01 SE 52 60144 05/21/01 Ru-103 -2. 56E+01 2. 90E+01 1. 11E+02 SE 52 60144 05/21/01 Ru-106 8. 11E+01 2. 04E+02 7. 30E+02 SE 52 60144 05/21/01 Sb-124 1. 74E+01 5. 79E+01 2. 29E+ 02 SE 52 60144 05/21/01 Se-75 -2. 06E+01 3. 05E+01 1. 10E+02 SE 52 60144 05/21/01 Th-232 1. 38E+03 1. 12E+02 3 .54E+02
- SE 52 60144 05/21/01 Zn-65 -9. 94E+01 1. 21E+02 4 .35E+02 SE 52 60144 05/21/01 Zr-95 7 47E+01 5. 28E+01 1. 75E+02
- Concentration Greater than 3 Standard Deviations 60
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 52 60145 05/21/01 Ag-IIOM 4. 59E+01 3.63E+01 1.22E+02 SE 52 60145 05/21/01 Ba-140 4. 63E+02 2.31E+02 7.31E+02 SE 52 60145 05/21/01 Be-7 -1.75E+02 2. 22E+02 8.47E+02 SE 52 60145 05/21/01 Ce-141 6. 78E+01 4. 66E+01 1. 54E+02 SE 52 60145 05/21/01 Ce-144 -1. 24E+02 1.43E+02 5. 06E+02 SE 52 60145 05/21/01 Co-57 -9. 58E+00 1.77E+01 6. 22E+01 SE 52 60145 05/21/01 Co-58 5. 10E+00 2 .44E+01 9. 10E+01 SE 52 60145 05/21/01 Co-60 -1. 34E+01 2.77E+01 1.11E+02 SE 52 60145 05/21/01 Cr-51 5. 74E+01 2.76E+02 9. 74E+02 SE 52 60145 05/21/01 Cs-134 2. 44E+01 2. 05E+01 6. 92E+01 SE 52 60145 05/21/01 Cs-137 -5. 17E+01 2.61E+01 1. 07E+02 SE 52 60145 05/21/01 Fe-59 -6. 92E+01 1. O1E+02 4 . OOE+02 SE 52 60145 05/21/01 1-131 2. 48E+02 1. 47E+02 4 .82E+02 SE 52 60145 05/21/01 K-40 1. 14E+04 8. 50E+02 1.03E+03
- SE 52 60145 05/21/01 Mn-54 -3. 53E+01 2. 69E+01 1. 07E+02 SE 52 60145 05/21/01 Ru-103 -1. 57E+01 2. 77E+01 1. 05E+02 SE 52 60145 05/21/01 Ru-106 5. 09E+01 2.21E+02 7. 97E+02 SE 52 60145 05/21/01 Sb-124 -1. 10E+02 5. 17E+01 2.74E+02 SE 52 60145 05/21/01 Se-75 -2. 64E+01 3. 10E+01 1. 13E+02 SE 52 60145 05/21/01 Th-232 1. 01E+03 1. 24E+02 3.66E+02
- SE 52 60145 05/21/01 Zn-65 -7. 04E+01 1.21E+02 4. 35E+02 SE 52 60145 05/21/01 Zr-95 -1. 57E+01 4.79E+01 1. 83E+02 SE 52 63137 11/19/01 Ag-IIOM 5. 39E+01 4 00E+01 1. 33E+02 SE 52 63137 11/19/01 Ba-140 -1.51E+02 4. 51E+02 1. 60E+03 SE 52 63137 11/19/01 Be-7 6. 57E+02 2. 96E+02 9. 50E+02 SE 52 63137 11/19/01 Ce-141 1. 04E+02 7. 57E+01 2. 50E+02 SE 52 63137 11/19/01 Ce-144 1. OOE+02 1. 85E+02 6.19E+02 SE 52 63137 11/19/01 Co-57 -3. 76E+01 2. 38E+01 8. 25E+01 SE 52 63137 11/19/01 Co-58 -4. 30E+01 3. 19E+01 1. 22E+02 SE 52 63137 11/19/01 Co-60 -3. 52E+00 2. 96E+01 1. 09E+02 SE 52 63137 11/19/01 Cr-51 -7. 28E+01 4. 35E+02 1. 50E+03 SE 52 63137 11/19/01 Cs-134 2. 48E+01 2. 70E+01 9. 11E+01 SE 52 63137 11/19/01 Cs-137 -6. 75E+01 3. 26E+01 1. 22E+02 SE 52 63137 11/19/01 Fe-59 8. 82E+00 9. 58E+01 3. 51E+02 SE 52 63137 11/19/01 1-131 1. 17E+02 3. 14E+02 1. 07E+03 SE 52 63137 11/19/01 K-40 1. 07E+04 7 41E+02 1.24E+03
- SE 52 63137 11/19/01 Mn-54 7. 60E+01 3. 20E+01 1.01E+02 SE 52 63137 11/19/01 Ru-103 1. 89E+01 3. 67E+01 1. 27E+02 SE 52 63137 11/19/01 Ru-106 -2. 16E+02 2 .73E+02 9. 85E+02 SE 52 63137 11/19/01 Sb-124 5. 62E+01 6. 59E+01 2. 34E+02 SE 52 63137 11/19/01 Se-75 -5. 85E+00 4 .08E+01 1. 40E+02 SE 52 63137 11/19/01 Th-232 3. 63E+03 1. 34E+02 3.51E+02
- SE 52 63137 11/19/01 Zn-65 3.27E+02 1. 42E+02 4. 57E+02 SE 52 63137 11/19/01 Zr-95 1. 53E+02 6. 68E+01 2. 12E+02
- Concentration Greater than 3 Standard Deviations 61
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 52 63138 11/19/01 Ag-11CM 1. 53E+01 2. 16E+01 7 .49E+01 SE 52 63138 11/19/01 Ba-140 -2. 57E+02 3. 16E+02 1. 13E+03 SE 52 63138 11/19/01 Be-7 -1. 82E+02 1. 90E+02 6. 8 9E+02 SE 52 63138 11/19/01 Ce-141 -7 . 82E+00 4. 81E+01 1. 64E+02 SE 52 63138 11/19/01 Ce-144 1. 19E+02 1. 27E+02 4 .22E+02 SE 52 63138 11/19/01 Co-57 6. 97E+00 1. 54E+01 5. 19E+01 SE 52 63138 11/19/01 Co-58 0. OOE+00 2. 12E+01 7. 54E+01 SE 52 63138 11/19/01 Co-60 1. 21E+01 1. 80E+01 6. 29E+01 SE 52 63138 11/19/01 Cr-51 -3. 27E+02 2. 85E+02 1. 02E+03 SE 52 63138 11/19/01 Cs-134 1. 27E+01 1. 61E+01 5. 48E+01 SE 52 63138 11/19/01 Cs-137 -2. 16E+00 1. 81E+01 6. 43E+01 SE 52 63138 11/19/01 Fe-59 6. 39E+01 6. 11E+01 2.09E+02 SE 52 63138 11/19/01 1-131 1.09E+02 1. 95E+02 6. 66E+02 SE 52 63138 11/19/01 K-40 1 .29E+04 5. 83E+02 7.36E+02 SE 52 63138 11/19/01 Mn-54 -5. 23E+00 1. 90E+01 6. 80E+01 SE 52 63138 11/19/01 Ru-103 8. 39E+00 2.43E+01 8.43E+01 SE 52 63138 11/19/01 Ru-106 8. 27E+01 1. 52E+02 5.25E+02 SE 52 63138 11/19/01 Sb-124 -2. 19E+01 3. 10E+01 1. 32E+02 SE 52 63138 11/19/01 Se-75 3. 11E+01 2. 55E+01 8. 47E+01 SE 52 63138 11/19/01 Th-232 1. 49E+03 7.22E+01 2.38E+02 SE 52 63138 11/19/01 Zn-65 9. 03E+01 8.37E+01 2.79E+02 SE 52 63138 11/19/01 Zr-95 5. 32E+01 3.66E+01 1.21E+02 SE 52 63139 11/19/01 Ag-IIOM -9. 71E+00 1. 97E+01 7. 34E+01 SE 52 63139 11/19/01 Ba-140 -5. 02E+02 2. 34E+02 9. 03E+02 SE 52 63139 11/19/01 Be-7 2. 45E+02 1. 66E+02 5. 50E+02 SE 52 63139 11/19/01 Ce-141 1. 09E+01 4.18E+01 1. 42E+02 SE 52 63139 11/19/01 Ce-144 -9. 44E+01 1. 05E+02 3. 66E+02 SE 52 63139 11/19/01 Co-57 9. 60E+00 1.34E+01 4.51E+01 SE 52 63139 11/19/01 Co-58 2. 24E+01 1. 63E+01 5. 41E+01 SE 52 63139 11/19/01 Co-60 -1. 28E+01 1.53E+01 5. 93E+01 SE 52 63139 11/19/01 Cr-51 9. 75E+01 2.36E+02 8. 08E+02 SE 52 63139 11/19/01 Cs-134 1. 55E+01 2. 18E+01 7.21E+01 SE 52 63139 11/19/01 Cs-137 -1. 64E+01 1.58E+01 5. 89E+01 SE 52 63139 11/19/01 Fe-59 -5. 69E+01 5.82E+01 2 . 25E+02 SE 52 63139 11/19/01 1-131 1. 93E+02 1. 64E+02 5. 50E+02 SE 52 63139 11/19/01 K-40 1. 20E+04 5.4 8E+02 6.61E+02 SE 52 63139 11/19/01 Mn-54 3. 88E+01 1.72E+01 5. 45E+01 SE 52 63139 11/19/01 Ru-103 -1. 30E+01 2.05E+01 7.49E+01 SE 52 63139 11/19/01 Ru-106 2. 83E+02 1. 33E+02 4. 23E+02 SE 52 63139 11/19/01 Sb-124 -3. 01E+01 2.38E+01 1. 13E+02 SE 52 63139 11/19/01 Se-75 2. 97E+01 2.01E+01 6. 64E+01 SE 52 63139 11/19/01 Th-232 1. 40E+03 6. 75E+01 2.03E+02 SE 52 63139 11/19/01 Zn-65 6. 65E+01 7. 56E+01 2. 54E+02 SE 52 63139 11/19/01 Zr-95 3. 17E+01 3. 89E+01 1. 33E+02 Concentration Greater than 3 Standard Deviations 62
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 57 60152 05/22/01 Ag-IIOM -2.25E+01 2.62E+01 1.07E+02 SE 57 60152 05/22/01 Ba-140 -1.70E+02 1.78E+02 7.08E+02 SE 57 60152 05/22/01 Be-7 -1.28E+02 1.52E+02 6.03E+02 SE 57 60152 05/22/01 Ce-141 -1.60E+01 2.63E+01 9.63E+01 SE 57 60152 05/22/01 Ce-144 -9.71E+01 8.10E+01 3.02E+02 SE 57 60152 05/22/01 Co-57 -1.53E+01 9.54E+00 3.63E+01 SE 57 60152 05/22/01 Co-58 -4.58E+01 1.94E+01 8.87E+01 SE 57 60152 05/22/01 Co-60 0.OOE+00 2.23E+01 8.72E+01 SE 57 60152 05/22/01 Cr-51 -7.47E+01 1.91E+02 7.12E+02 SE 57 60152 05/22/01 Cs-134 1.21E+01 1.30E+01 4.55E+01 SE 57 60152 05/22/01 Cs-137 -6.34E+00 1.69E+01 6.60E+01 SE 57 60152 05/22/01 Fe-59 -4.59E+01 5.95E+01 2.58E+02 SE 57 60152 05/22/01 1-131 -2.56E+01 9.23E+01 3.44E+02 SE 57 60152 05/22/01 K-40 1.32E+04 8.49E+02 8.12E+02
- SE 57 60152 05/22/01 Mn-54 1.40E+01 1.56E+01 5.53E+01 SE 57 60152 05/22/01 Ru-103 1.72E+01 2.15E+01 7.54E+01 SE 57 60152 05/22/01 Ru-106 1.22E+02 1.77E+02 6.22E+02 SE 57 60152 05/22/01 Sb-124 3.29E+01 2.33E+01 4.45E+01 SE 57 60152 05/22/01 Se-75 -5.74E+00 2.06E+01 7.49E+01 SE 57 60152 05/22/01 Th-232 2.1lE+02 9.81E+01 3.08E+02 SE 57 60152 05/22/01 Zn-65 -1.54E+02 5.03E+01 2.31E+02 SE 57 60152 05/22/01 Zr-95 3.92E+01 3.61E+01 1.25E+02 SE 57 60153 05/22/01 Ag-IIOM -3.83E+01 2.74E+01 1.17E+02 SE 57 60153 05/22/01 Ba-140 -4.90E+02 1.94E+02 8.44E+02 SE 57 60153 05/22/01 Be-7 2.22E+02 1.42E+02 4.62E+02 SE 57 60153 05/22/01 Ce-141 7.18E+01 3.09E+01 9.74E+01 SE 57 60153 05/22/01 Ce-144 2.97E+01 9.11E+01 3.18E+02 SE 57 60153 05/22/01 Co-57 1.40E+01 1.16E+01 3.89E+01 SE 57 60153 05/22/01 Co-58 9.17E+00 2.36E+01 8.66E+01 SE 57 60153 05/22/01 Co-60 8.79E+00 1.61E+01 6.23E+01 SE 57 60153 05/22/01 Cr-51 -1.09E+02 1.96E+02 7.43E+02 SE 57 60153 05/22/01 Cs-134 -8.40E+00 1.82E+01 6.97E+01 SE 57 60153 05/22/01 Cs-137 5.68E+00 2.07E+01 7.59E+01 SE 57 60153 05/22/01 Fe-59 2.12E+01 6.70E+01 2.57E+02 SE 57 60153 05/22/01 1-131 -1.05E+02 9.40E+01 3.72E+02 SE 57 60153 05/22/01 K-40 1.49E+04 9.27E+02 8.72E+02
- SE 57 60153 05/22/01 Mn-54 -0.16E+00 2.06E+01 7.80E+01 SE 57 60153 05/22/01 Ru-103 -7.44E+00 1.90E+01 7.49E+01 SE 57 60153 05/22/01 Ru-106 -1.94E+01 1.84E+02 6.89E+02 SE 57 60153 05/22/01 Sb-124 -1.74E+01 3.01E+01 1.61E+02 SE 57 60153 05/22/01 Se-75 2.01E+01 1.98E+01 6.77E+01 SE 57 60153 05/22/01 Th-232 -1.94E+02 1.39E+02 5.53E+02 SE 57 60153 05/22/01 Zn-65 -1.15E+02 5.27E+01 2.31E+02 SE 57 60153 05/22/01 Zr-95 -3.83E+01 3.29E+01 1.42E+02
- Concentration Greater than 3 Standard Deviations 63
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 57 60154 05/22/01 Ag-IIOM 3. 06E+01 1. 83E+01 5. 93E+01 SE 57 60154 05/22/01 Ba-140 -1. 72E+02 1.56E+02 6. 07E+02 SE 57 60154 05/22/01 Be-7 -2. 64E+02 1.28E+02 5. 31E+02 SE 57 60154 05/22/01 Ce-141 -3. 62E+00 2. 99E+01 1. 05E+02 SE 57 60154 05/22/01 Ce-144 2. 10E+01 8. 01E+01 2. 79E+02 SE 57 60154 05/22/01 Co-57 1. 35E+01 1. 07E+01 3. 57E+01 SE 57 60154 05/22/01 Co-58 -1. 40E+01 1. 70E+01 6. 68E+01 SE 57 60154 05/22/01 Co-60 -7. 28E+00 9. 85E+00 4 .46E+01 SE 57 60154 05/22/01 Cr-51 -7 .80E+01 1. 43E+02 5. 41E+02 SE 57 60154 05/22/01 Cs-134 -1. 93E+01 1. 40E+01 5. 49E+01 SE 57 60154 05/22/01 Cs-137 -1.55E+01 1.37E+01 5. 50E+01 SE 57 60154 05/22/01 Fe-59 5. 19E+01 5. 06E+01 1.7 6E+02 SE 57 60154 05/22/01 1-131 6. 61E+00 7.44E+01 2.70E+02 SE 57 60154 05/22/01 K-40 1. 55E+04 7. 25E+02 7.25E+02
- SE 57 60154 05/22/01 Mn-54 7. 02E+00 1. 57E+01 5. 62E+01 SE 57 60154 05/22/01 Ru-103 1.26E+01 1. 65E+01 5. 78E+01 SE 57 60154 05/22/01 Ru-106 1. 88E+02 1. 45E+02 4 .87E+02 SE 57 60154 05/22/01 Sb-124 6. 20E+01 3. 02E+01 5. 84E+02 SE 57 60154 05/22/01 Se-75 -2. 59E+01 1. 68E+01 6. 47E+01 SE 57 60154 05/22/01 Th-232 2. 50E+02 6. 99E+01 2.12E+02
- SE 57 60154 05/22/01 Zn-65 1. 95E+01 4.23E+01 1. 50E+02 SE 57 60154 05/22/01 Zr-95 3. 50E+01 2. 95E+01 1. OOE+02 SE 57 63146 11/20/01 Ag-110M -1.39E+01 2. 08E+01 8. 15E+01 SE 57 63146 11/20/01 Ba-140 -7.95E+01 3. 04E+02 1. 12E+03 SE 57 63146 11/20/01 Be-7 -3. 94E+01 1.31E+02 4. 93E+02 SE 57 63146 11/20/01 Ce-141 -4 .46E+01 3. 16E+01 1. 15E+02 SE 57 63146 11/20/01 Ce-144 7. 81E+01 7. 61E+01 2. 56E+02 SE 57 63146 11/20/01 Co-57 -8. 21E+00 9. 24E+00 3. 30E+01 SE 57 63146 11/20/01 Co-58 -5. 13E+01 1. 68E+01 7. 67E+01 SE 57 63146 11/20/01 Co-60 -2.01E+01 1. 90E+01 7.73E+01 SE 57 63146 11/20/01 Cr-51 1. 33E+02 1. 91E+02 6. 62E+02 SE 57 63146 11/20/01 Cs-134 7.4 6E+00 1.33E+01 4. 69E+01 SE 57 63146 11/20/01 Cs-137 -1. 14E+01 1. 65E+01 6. 21E+01 SE 57 63146 11/20/01 Fe-59 -1. 12E+02 6. 58E+01 2.84E+02 SE 57 63146 11/20/01 1-131 -3. 40E+02 2. 12E+02 8. 24E+02 SE 57 63146 11/20/01 K-40 1. 36E+04 6. 86E+02 4.42E+02
- SE 57 63146 11/20/01 Mn-54 -1. 17E+01 1.57E+01 6. 09E+01 SE 57 63146 11/20/01 Ru-103 -5. 60E+00 1. 98E+01 7.40E+01 SE 57 63146 11/20/01 Ru-106 -1. 42E+02 1.29E+02 5. 05E+02 SE 57 63146 11/20/01 Sb-124 -6. 21E+01 3. 73E+01 1.8 6E+02 SE 57 63146 11/20/01 Se-75 9. 68E+00 1. 92E+01 6. 62E+01 SE 57 63146 11/20/01 Th-232 3. 32E+02 5. 80E+01 2.42E+02
- SE 57 63146 11/20/01 Zn-65 4 .21E+01 6. 92E+01 2. 38E+02 SE 57 63146 11/20/01 Zr-95 -3. 45E+01 3.20E+01 1. 28E+02
- Concentration Greater than 3 Standard Deviations 64
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEDIMENT SE 57 63147 11/20/01 Ag-11CM 1. 11E+01 2.06E+01 7.43E+01 SE 57 63147 11/20/01 Ba-140 -1. 34E+02 3. 17E+02 1. 18E+03 SE 57 63147 11/20/01 Be-7 1.70E+02 1. 62E+02 5. 52E+02 SE 57 63147 11/20/01 Ce-141 -1. 95E+01 3. 39E+01 1.21E+02 SE 57 63147 11/20/01 Ce-144 5. 42E+01 8. 13E+01 2. 77E+02 SE 57 63147 11/20/01 Co-57 -1. 58E+01 1. 03E+01 3. 75E+01 SE 57 63147 11/20/01 Co-58 1. 11E+01 1. 91E+01 6. 84E+01 SE 57 63147 11/20/01 Co-60 1. 73E+01 1.82E+01 6. 37E+01 SE 57 63147 11/20/01 Cr-51 1. 45E+02 2.42E+02 8. 36E+02 SE 57 63147 11/20/01 Cs-134 4. OOE+00 1. 43E+01 5. 13E+01 SE 57 63147 11/20/01 Cs-137 2. 22E+00 1. 52E+01 5. 54E+01 SE 57 63147 11/20/01 Fe-59 7. 87E+01 7 O1E+01 2.4 1E+02 SE 57 63147 11/20/01 1-131 -2. 90E+02 2. 31E+02 8. 85E+02 SE 57 63147 11/20/01 K-40 1. 42E+04 7. 29E+02 6.08E+02
- SE 57 63147 11/20/01 Mn-54 2. 50E+00 1. 48E+01 5. 48E+01 SE 57 63147 11/20/01 Ru-103 2. 11E+01 1. 93E+01 6. 61E+01 SE 57 63147 11/20/01 Ru-106 -3. 89E+01 1. 49E+02 5. 52E+02 SE 57 63147 11/20/01 Sb-124 0. OOE+00 3. 20E+01 1.41E+02 SE 57 63147 11/20/01 Se-75 5. 29E+00 1. 86E+01 6. 51E+01 SE 57 63147 11/20/01 Th-232 1. 40E+02 7 76E+01 2. 51E+02 SE 57 63147 11/20/01 Zn-65 3. 17E+00 7 82E+01 2. 75E+02 SE 57 63147 11/20/01 Zr-95 -1. 04E+01 3. 48E+01 1. 32E+02 SE 57 63148 11/20/01 Ag-IIOM 2. 96E+01 1. 84E+01 6. 03E+01 SE 57 63148 11/20/01 Ba-140 -1. 99E+02 2. 93E+02 1. 07E+03 SE 57 63148 11/20/01 Be-7 -1. 43E+02 1. 56E+02 5. 72E+02 SE 57 63148 11/20/01 Ce-141 -8.81E+01 3. 57E+01 1. 31E+02 SE 57 63148 11/20/01 Ce-144 -1.4 1E+02 8. 27E+01 2. 98E+02 SE 57 63148 11/20/01 Co-57 -1. 44E+01 1. 04E+01 3. 70E+01 SE 57 63148 11/20/01 Co-58 -1. 98E+00 1. 76E+01 6. 38E+01 SE 57 63148 11/20/01 Co-60 -0. 4 1E+00 1. 14E+01 4. 32E+01 SE 57 63148 11/20/01 Cr-51 -6. 88E+01 2. 24E+02 7. 93E+02 SE 57 63148 11/20/01 Cs-134 -9. 63E+00 1. 19E+01 4.41E+01 SE 57 63148 11/20/01 Cs-137 2. 86E+00 1. 38E+01 4.88E+01 SE 57 63148 11/20/01 Fe-59 1. 03E+02 5. 48E+01 1. 75E+02 SE 57 63148 11/20/01 1-131 -9. 23E+01 2. 22E+02 7. 93E+02 SE 57 63148 11/20/01 K-40 1.31E+04 5. 47E+02 6.39E+02
- SE 57 63148 11/20/01 Mn-54 -1. 25E+01 1. 30E+01 4. 94E+01 SE 57 63148 11/20/01 Ru-103 2. 02E+00 1. 80E+01 6. 43E+01 SE 57 63148 11/20/01 Ru-106 2. 74E+01 1. 10E+02 3. 90E+02 SE 57 63148 11/20/01 Sb-124 -5. 13E+00 2. 88E+01 1. 17E+02 SE 57 63148 11/20/01 Se-75 1. 29E+00 1. 81E+01 6. 28E+01 SE 57 63148 11/20/01 Th-232 3. 31E+02 5. 92E+01 2.O0E+02
- SE 57 63148 11/20/01 Zn-65 1.79E+02 7. 09E+01 2. 27E+02 SE 57 63148 11/20/01 Zr-95 1. 93E+01 2. 82E+01 9. 83E+01
- Concentration Greater than 3 Standard Deviations 65
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) FOOD CROP TF 02 60620 06/21/01 Th-232 -8. 27E+00 3. 98E+01 1. 60E+02 TF 02 60620 06/21/01 Ag-ilOM -1. 15E+01 1. 06E+01 5. 09E+01 TF 02 60620 06/21/01 Ba-140 1. 53E+01 1. 42E+01 5. 11E+01 TF 02 60620 06/21/01 Be-7 0 OOE+00 9. 99E+01 3. 77E+02 TF 02 60620 06/21/01 Ce-141 1 .40E+01 1. 72E+01 5. 92E+01 TF 02 60620 06/21/01 Ce-144 0. OOE+00 5. 55E+01 2. OOE+02 TF 02 60620 06/21/01 Co-57 2. 51E+01 1. 24E+01 3. 71E+01 TF 02 60620 06/21/01 Co-58 -7. 15E+00 1. 07E+01 4. 55E+01 TF 02 60620 06/21/01 Co-60 -7 .22E+00 1 49E+01 6. 17E+01 TF 02 60620 06/21/01 Cr-51 -1. 58E+01 1 15E+02 4. 25E+02 TF 02 60620 06/21/01 Cs-134 7. 02E+00 1. 32E+01 4.86E+01 TF 02 60620 06/21/01 Cs-137 -9. 61E+00 1.23E+01 5.OOE+01 TF 02 60620 06/21/01 Fe-59 3. 06E+01 4. 36E+01 1.58E+02 TF 02 60620 06/21/01 1-131 3. 11E+01 3. 36E+01 1. 16E+02 TF 02 60620 06/21/01 K-40 1. 69E+03 3. 04E+02 6.79E+02
- TF 02 60620 06/21/01 Mn-54 -1. 96E+01 1. 18E+01 5.21E+01 TF 02 60620 06/21/01 Ru-103 9. 04E+00 1. 20E+01 4.25E+01 TF 02 60620 06/21/01 Ru-106 5. 07E+01 1.29E+02 4. 66E+02 TF 02 60620 06/21/01 Sb-124 2. 04E+01 2. 04E+01 7.52E+01 TF 02 60620 06/21/01 Se-75 1.87E+00 1. 22E+01 5. 03E+01 TF 02 60620 06/21/01 Zn-65 6. 35E+00 2. 91E+01 1. 11E+02 TF 02 60620 06/21/01 Zr-95 -3. 40E+01 1. 86E+01 8. 67E+01 TF 02 61209 07/26/01 Th-232 3. 18E+01 4. 92E+01 1. 78E+02 TF 02 61209 07/26/01 Ag-11OM 1. 56E+01 1. 62E+01 5. 71E+01 TF 02 61209 07/26/01 Ba-140 2. 20E+01 1.27E+01 1. 98E+01 TF 02 61209 07/26/01 Be-7 -3. 71E+01 9. 82E+01 3. 85E+02 TF 02 61209 07/26/01 Ce-141 8.4 1E+00 1. 64E+01 5. 76E+01 TF 02 61209 07/26/01 Ce-144 2. 4 1E+01 6. 22E+01 2. 19E+02 TF 02 61209 07/26/01 Co-57 0. OOE+00 7. 36E+00 2. 65E+01 TF 02 61209 07/26/01 Co-58 -2. 51E+00 1.07E+01 4.41E+01 TF 02 61209 07/26/01 Co-60 -6. 72E+00 1.36E+01 5. 83E+01 TF 02 61209 07/26/01 Cr-51 -1. 64E+01 1. 17E+02 4. 34E+02 TF 02 61209 07/26/01 Cs-134 1.37E+01 1. 46E+01 5. 14E+01 TF 02 61209 07/26/01 Cs-137 5. 54E+00 1.40E+01 5. 13E+01 TF 02 61209 07/26/01 Fe-59 5. 13E+01 2.29E+01 2. 77E+01 TF 02 61209 07/26/01 1-131 0. OOE+00 2. 66E+01 9. 91E+01 TF 02 61209 07/26/01 K-40 2. 74E+03 3. 58E+02 6.OOE+02
- TF 02 61209 07/26/01 Mn-54 -1. 61E+01 1 .21E+01 5. 26E+01 TF 02 61209 07/26/01 Ru-103 -4. 72E+00 1. 20E+01 4.75E+01 TF 02 61209 07/26/01 Ru-106 -9. 34E+01 1. 20E+02 4 .80E+02 TF 02 61209 07/26/01 Sb-124 5. 37E+01 2 84E+01 7. 91E+01 TF 02 61209 07/26/01 Se-75 -3. 78E+00 1. 54E+01 5. 64E+01 TF 02 61209 07/26/01 Zn-65 -1. 35E+01 3. 16E+01 1. 27E+02 TF 02 61209 07/26/01 Zr-95 1. 36E+01 1. 75E+01 6. 43E+01
- Concentration Greater than 3 Standard Deviations 66
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) FOOD CROP TF 02 61553 08/23/01 Th-232 1. 08E+01 4. 48E+01 1. 69E+02 TF 02 61553 08/23/01 Ag-IIOM 2. 21E+00 1. 65E+01 6. 32E+01 TF 02 61553 08/23/01 Ba-140 3. 16E+01 2.26E+01 7.47E+01 TF 02 61553 08/23/01 Be-7 1. 63E-05 9. 69E+01 3. 65E+02 TF 02 61553 08/23/01 Ce-141 1. 00E+01 1. 57E+01 5. 47E+01 TF 02 61553 08/23/01 Ce-144 2 49E+01 5. 47E+01 1. 92E+02 TF 02 61553 08/23/01 Co-57 9. 70E+00 7 . OOE+00 2. 33E+01 TF 02 61553 08/23/01 Co-58 0.OOE+00 9. 54E+00 3. 85E+01 TF 02 61553 08/23/01 Co-60 -1. 99E+01 1. 01E+01 5. 24E+01 TF 02 61553 08/23/01 Cr-51 -2. 02E+02 1. 06E+02 4. 37E+02 TF 02 61553 08/23/01 Cs-134 -2. 19E+01 1.09E+01 5. 12E+01 TF 02 61553 08/23/01 Cs-137 -1. 92E+00 1. 19E+01 4.61E+01 TF 02 61553 08/23/01 Fe-59 1. 43E+01 3. 16E+01 1. 23E+02 TF 02 61553 08/23/01 1-131 3. 23E+01 2. 96E+01 1. 01E+02 TF 02 61553 08/23/01 K-40 2. 63E+03 3. 42E+02 6. 20E+02
- TF 02 61553 08/23/01 Mn-54 -1. 85E+01 1. 18E+01 5. 12E+01 TF 02 61553 08/23/01 Ru-103 -6. 60E+00 1. 10E+01 4 42E+01 TF 02 61553 08/23/01 Ru-106 -1. 07E+02 1. 11E+02 4 47E+02 TF 02 61553 08/23/01 Sb-124 -1. 98E+01 1. 98E+01 1. 07E+02 TF 02 61553 08/23/01 Se-75 -1. 89E+01 1. 39E+01 S. 40E+01 TF 02 61553 08/23/01 Zn-65 -1. 83E+01 2.20E+01 9. 67E+01 TF 02 61553 08/23/01 Zr-95 1. 48E+01 2. 01E+01 7. 28E+01 TF 03 60621 06/21/01 Th-232 3. 49E+01 4. 39E+01 1. 58E+02 TF 03 60621 06/21/01 Ag-lIOM -1.07E+01 1.36E+01 5. 99E+01 TF 03 60621 06/21/01 Ba-140 0. 00E+00 1. 13E+01 5. 89E+01 TF 03 60621 06/21/01 Be-7 1.74E+01 7. 96E+01 3. 02E+02 TF 03 60621 06/21/01 Ce-141 1 . 07E+00 1. 18E+01 4. 30E+01 TF 03 60621 06/21/01 Ce-144 -6.26E+01 4 .61E+01 1.80E+02 TF 03 60621 06/2 1/01 Co-57 1 .77E+00 5. 16E+00 1.85E+01 TF 03 60621 06/2 1/01 Co-58 -2. 81E+00 9. 80E+00 4. 11E+01 TF 03 60621 06/21/01 Co-60 1.37E+01 1. 41E+01 5.03E+01 TF 03 60621 06/2 1/01 Cr-51 -4. 50E+01 9. 36E+01 3.60E+02 TF 03 60621 06/2 1/01 Cs-134 1. 19E+00 1. 08E+01 4.28E+01 TF 03 60621 06/21/01 Cs-137 -2 84E+00 9.89E+00 4. 03E+01 TF 03 60621 06/21/01 Fe-59 4. 88E+01 3. 62E+01 1.22E+02 TF 03 60621 06/21/01 1-131 8 49E+00 2. 33E+01 8. 54E+01 TF 03 60621 06/21/01 K-40 1. 15E+03 2. 62E+02 6.08E+02 TF 03 60621 06/21/01 Mn-54 1. 05E+01 1. 11E+01 3. 94E+01 TF 03 60621 06/21/01 Ru-103 -1. 34E+01 9. 96E+00 4.34E+01 TF 03 60621 06/21/01 Ru-106 -8. 86E+01 8. 15E+01 3. 58E+02 TF 03 60621 06/21/01 Sb-124 3. 39E+01 2. 53E+01 8.31E+01 TF 03 60621 06/21/01 Se-75 6. 66E+00 1. 16E+01 4. 10E+01 TF 03 60621 06/21/01 Zn-65 6. 75E+00 2. 62E+01 1. 01E+02 TF 03 60621 06/21/01 Zr-95 8 .42E+00 1. 64E+01 6. 27E+01 Concentration Greater than 3 Standard Deviations 67
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) FOOD CROP TF 03 61210 07/26/01 Th-232 -1. 71E+01 4.61E+01 1. 89E+02 TF 03 61210 07/26/01 Ag-IIOM -3. 40E+01 1. 61E+01 7. 82E+01 TF 03 61210 07/26/01 Ba-140 1. 73E+01 2.44E+01 9.28E+01 TF 03 61210 07/26/01 Be-7 -1. 96E+01 9. 38E+01 3. 68E+02 TF 03 61210 07/26/01 Ce-141 1. 88E+01 1.38E+01 4 .60E+01 TF 03 61210 07/26/01 Ce-144 1. 47E+01 5. 47E+01 1. 95E+02 TF 03 61210 07/26/01 Co-57 -4. 71E+00 5. 75E+00 2 22E+01 TF 03 61210 07/26/01 Co-58 2. 11E+01 1.22E+01 3. 86E+01 TF 03 61210 07/26/01 Co-60 2. 51E+01 1.59E+01 5. 13E+01 TF 03 61210 07/26/01 Cr-51 1. 67E+02 10. OE+01 3. 25E+02 TF 03 61210 07/26/01 Cs-134 1. 99E+01 1.26E+01 4. 07E+01 TF 03 61210 07/26/01 Cs-137 -2. 13E+01 1. 17E+01 5. 35E+01 TF 03 61210 07/26/01 Fe-59 -9. 48E+01 3. 95E+01 2. 03E+02 TF 03 61210 07/26/01 1-131 4 .42E+00 2. 30E+01 8. 61E+01 TF 03 61210 07/26/01 K-40 1. 82E+03 3. 38E+02 7. 13E+02 TF 03 61210 07/26/01 Mn-54 -5. 97E+00 1. 12E+01 4. 74E+01 TF 03 61210 07/26/01 Ru-103 1. 75E+01 1 .09E+01 3. 52E+01 TF 03 61210 07/26/01 Ru-106 -8. 15E+01 1. 02E+02 4. 29E+02 TF 03 61210 07/26/01 Sb-124 -2. 55E+01 3. 12E+01 1. 53E+02 TF 03 61210 07/26/01 Se-75 7. 56E+00 1. 42E+01 5. 01E+01 TF 03 61210 07/26/01 Zn-65 -7 . 69E+00 2. 31E+01 1. 01E+02 TF 03 61210 07/26/01 Zr-95 0 OOE+00 1. 97E+01 7. 94E+01 TF 03 61554 08/23/01 Th-232 1.75E+01 3. 60E+01 1.39E+02 TF 03 61554 08/23/01 Ag-IIOM 1.24E+01 1.24E+01 4. 44E+01 TF 03 61554 08/23/01 Ba-140 -4. 54E+01 2.40E+01 1. 28E+02 TF 03 61554 08/23/01 Be-7 -3. 78E+01 1. 00E+02 3. 92E+02 TF 03 61554 08/23/01 Ce-141 -1.41E+01 1.47E+01 5. 60E+01 TF 03 61554 08/23/01 Ce-144 -1. 03E+00 4.88E+01 1. 78E+02 TF 03 61554 08/23/01 Co-57 -6. 75E+00 5.76E+00 2. 25E+01 TF 03 61554 08/23/01 Co-58 5. 73E+00 1. 12E+01 4. 23E+01 TF 03 61554 08/23/01 Co-60 -1.47E+01 1.03E+01 5. 41E+01 TF 03 61554 08/23/01 Cr-51 3. 30E+01 1 . 07E+02 3. 88E+02 TF 03 61554 08/23/01 Cs-134 1.75E+01 1. 16E+01 3. 78E+01 TF 03 61554 08/23/01 Cs-137 5.23E+00 1.08E+01 4. 06E+01 TF 03 61554 08/23/01 Fe-59 -3.31E+01 4.29E+01 1.86E+02 TF 03 61554 08/23/01 1-131 9. 93E+00 2.81E+01 1.03E+02 TF 03 61554 08/23/01 K-40 1 . 82E+03 3. 32E+02 7 .10E+02 TF 03 61554 08/23/01 Mn-54 1.41E+01 1. 41E+01 4 92E+01 TF 03 61554 08/23/01 Ru-103 -4. 87E+00 1.24E+01 4. 90E+01 TF 03 61554 08/23/01 Ru-106 -6. 97E+01 1.20E+02 4. 75E+02 TF 03 61554 08/23/01 Sb-124 3. 69E+01 3.25E+01 1. 14E+02 TF 03 61554 08/23/01 Se-75 0. OOE+00 1.25E+01 4. 59E+01 TF 03 61554 08/23/01 Zn-65 -3. 64E+01 3. 64E+01 1. 51E+02 TF 03 61554 08/23/01 Zr-95 3. 07E+01 2. 18E+01 7. 25E+01
- Concentration Greater than 3 Standard Deviations 68
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) FOOD CROP TF 06 60622 06/21/01 Th-232 1.4 6E+01 5. 51E+01 2.06E+02 TF 06 60622 06/21/01 Ag-IlOM -4.22E+00 1. 40E+01 5. 95E+01 TF 06 60622 06/21/01 Ba-140 8. 73E+00 1. 51E+01 6. 43E+01 TF 06 60622 06/21/01 Be-7 0. 00E+00 9. 87E+01 3. 77E+02 TF 06 60622 06/21/01 Ce-141 0. 00E+00 1. 54E+01 5. 59E+01 TF 06 60622 06/21/01 Ce-144 3. 37E+01 5. 08E+01 1. 78E+02 TF 06 60622 06/21/01 Co-57 -0. 82E+00 6.41E+00 2. 35E+01 TF 06 60622 06/21/01 Co-58 2. 10E+01 1.27E+01 4. 05E+01 TF 06 60622 06/21/01 Co-60 -2. 61E+01 1. 67E+01 7. 67E+01 TF 06 60622 06/21/01 Cr-51 -1. 01E+02 1. 14E+02 4 .4 6E+02 TF 06 60622 06/21/01 Cs-134 1. 64E+01 1. 42E+01 4. 90E+01 TF 06 60622 06/21/01 Cs-137 -1. 93E+01 1.37E+01 5. 81E+01 TF 06 60622 06/21/01 Fe-59 2. 02E+01 2. 95E+01 1. 14E+02 TF 06 60622 06/21/01 1-131 -3. 88E+01 2.75E+01 1. 14E+02 TF 06 60622 06/21/01 K-40 1. 15E+03 3. 10E+02 8. 29E+02
- TF 06 60622 06/21/01 Mn-54 2. 65E+00 1.26E+01 4. 84E+01 TF 06 60622 06/21/01 Ru-103 0 OOE+00 1. 05E+01 4. 14E+01 TF 06 60622 06/21/01 Ru-106 5. 67E+01 1. 14E+02 4 .17E+02 TF 06 60622 06/21/01 Sb-124 -2. 46E+01 3. 01E+01 1. 48E+02 TF 06 60622 06/21/01 Se-75 -1. 13E+01 1. 36E+01 5.23E+01 TF 06 60622 06/21/01 Zn-65 2. 96E+01 2. 10E+01 6.88E+01 TF 06 60622 06/21/01 Zr-95 -8. 64E+00 2. 16E+01 8.87E+01 TF 06 61211 07/26/01 Th-232 3. 33E+00 3. 50E+01 1. 41E+02 TF 06 61211 07/26/01 Ag-IIOM -1. 15E+01 1. 58E+01 6. 68E+01 TF 06 61211 07/26/01 Ba-140 -5. 24E+01 2. 70E+01 1. 30E+02 TF 06 61211 07/26/01 Be-7 -1. 04E+02 8. 52E+01 3. 61E+02 TF 06 61211 07/26/01 Ce-141 6. 85E+00 1. 41E+01 4. 98E+01 TF 06 61211 07/26/01 Ce-144 4. 69E+01 4. 96E+01 1. 70E+02 TF 06 61211 07/26/01 Co-57 -9. 83E+00 6. 13E+00 2. 41E+01 TF 06 61211 07/26/01 Co-58 2. 10E+00 9. 11E+00 3. 65E+01 TF 06 61211 07/26/01 Co-60 -3. 89E+00 1. 66E+01 6. 65E+01 TF 06 61211 07/26/01 Cr-51 7.48E+01 8. 59E+01 3. 01E+02 TF 06 61211 07/26/01 Cs-134 -1.42E+01 9. 15E+00 4.47E+01 TF 06 61211 07/26/01 Cs-137 -7. 37E+00 1.29E+01 5. 12E+01 TF 06 61211 07/26/01 Fe-59 1. 42E+01 3. 78E+01 1. 4 6E+02 TF 06 61211 07/26/01 1-131 -2. 03E+01 2. 17E+01 8.77E+01 TF 06 61211 07/26/01 K-40 1. 55E+03 3. 03E+02 6.83E+02
- TF 06 61211 07/26/01 Mn-54 -2. 85E+00 1.02E+01 4.19E+01 TF 06 61211 07/26/01 Ru-103 -6. 66E+00 1. 02E+01 4. 18E+01 TF 06 61211 07/26/01 Ru-106 -1. 96E+02 1. 10E+02 4.74E+02 TF 06 61211 07/26/01 Sb-124 3.32E+01 1. 92E+01 3. 00E+01 TF 06 61211 07/26/01 Se-75 6. 83E+00 1.25E+01 4.43E+01 TF 06 61211 07/26/01 Zn-65 -2.02E+01 3. 37E+01 1. 35E+02 TF 06 61211 07/26/01 Zr-95 -1.80E+01 1.70E+01 7.68E+01
- Concentration Greater than 3 Standard Deviations 69
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) FOOD CROP TF 06 61555 08 /23/01 Th-232 -1 66E+01 2. 92E+01 1. 12E+02 TF 06 61555 08 /23/01 Ag-IIOM -1 56E+01 1. 05E+01 4. 34E+01 TF 06 61555 08 /23/01 Ba-140 3. 65E+00 8. 15E+00 3. 39E+01 TF 06 61555 08 /23/01 Be-7 -6. 17E+01 5. 50E+01 2. 20E+02 TF 06 61555 08 /23/01 Ce-141 2 02E+01 1. 07E+01 3. 47E+01 TF 06 61555 08 /23/01 Ce-144 7 65E+00 3. 61E+01 1. 27E+02 TF 06 61555 08 /23/01 Co-57 -6. 28E+00 4. 60E+00 1. 73E+01 TF 06 61555 08 /23/01 Co-58 -1. 06E+01 7. 12E+00 3. 00E+01 TF 06 61555 08 /23/01 Co-60 1. 03E+00 8. 57E+00 3. 23E+01 TF 06 61555 08 /23/01 Cr-51 -8. 27E+00 7. 62E+01 2. 75E+02 TF 06 61555 08 /23/01 Cs-134 1. 29E+01 7. 59E+00 2. 45E+01 TF 06 61555 08 /23/01 Cs-137 6. 11E+00 6.34E+00 2. 21E+01 TF 06 61555 08 /23/01 Fe-59 -2. 60E+01 2. 33E+01 9. 71E+01 TF 06 61555 08 /23/01 1-131 5. 16E+00 2. 03E+01 7. 28E+01 TF 06 61555 08 /23/01 K-40 1. 96E+03 2. 05E+02 3. 72E+02
- TF 06 61555 08 /23/01 Mn-54 7. 03E+00 6. 60E+00 2. 28E+01 TF 06 61555 08 /23/01 Ru-103 -3. 51E+00 8. 04E+00 3. 03E+01 TF 06 61555 08 /23/01 Ru-106 -1. 89E+02 6. 64E+01 2. 87E+02 TF 06 61555 08 /23/01 Sb-124 -9. 41E+00 1. 88E+01 7. 84E+01 TF 06 61555 08 /23/01 Se-75 -6. 38E+00 8. 21E+00 3. 06E+01 TF 06 61555 08 /23/01 Zn-65 -7. 08E+01 1. 87E+01 8. 56E+01 TF 06 61555 08 /23/01 Zr-95 -2. 64E+00 1. 28E+01 4 89E+01
- Concentration Greater than 3 Standard Deviations 70
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 04 58091 01/10/01 Th-232 -0. 45E+00 7. 10E+00 2. 61E+01 TM 04 58091 01/10/01 Ag-11OM 3. 69E+00 2. 56E+00 8. 4 9E+00 TM 04 58091 01/10/01 Ba-140 -0. 74E+00 3. 54E+00 1. 39E+01 TM 04 58091 01/10/01 Be-7 5. 28E+00 1. 42E+01 5. 04E+01 TM 04 58091 01/10/01 Ce-141 3. 09E+00 3. 03E+00 1. 01E+01 TM 04 58091 01/10/01 Ce-144 -1. 09E+01 1. 10E+01 3. 88E+01 TM 04 58091 01/10/01 Co-57 0. 77E+00 1. 38E+00 4 .68E+00 TM 04 58091 01/10/01 Co-58 -1. 61E+00 1. 90E+00 7 . 36E+00 TM 04 58091 01/10/01 Co-60 0 .23E+00 1. 89E+00 7. 13E+00 TM 04 58091 01/10/01 Cr-51 -2. 20E+01 1. 69E+01 6. 31E+01 TM 04 58091 01/10/01 Cs-134 1.72E+00 1. 64E+00 5. 65E+00 TM 04 58091 01/10/01 Cs-137 0. 28E+00 1. 85E+00 6. 68E+00 TM 04 58091 01/10/01 Fe-59 -2. 22E+00 6. 30E+00 2.40E+01 TM 04 58091 01/10/01 1-131 -7. 09E-02 7. 98E-02 0.70E+00 TM 04 58091 01/10/01 K-40 1. 33E+03 7. 32E+01 8.18E+01
- TM 04 58091 01/10/01 Mn-54 0. OOE+00 2. OOE+00 7 . 27E+00 TM 04 58091 01/10/01 Ru-103 -0. 68E+00 2. 53E+00 9. 12E+00 TM 04 58091 Ol/ 10/01 Ru-106 -2. 57E+01 1. 55E+01 6. 16E+01 TM 04 58091 Ol/ 10/01 Sb-124 -2. 07E+00 4. 39E+00 1. 80E+01 TM 04 58091 Ol/ 10/01 Se-75 1. 77E+00 2. 21E+00 7. 50E+00 TM 04 58091 01/ 10/01 Zn-65 -1. 15E+01 5. 57E+00 2.40E+01 TM 04 58091 Ol/ 10/01 Zr-95 0. 65E+00 3. 18E+00 1. 16E+01 TM 04 58593 02/14/01 Th-232 -3. 32E+00 6. 98E+00 2. 53E+01 TM 04 58593 02/14/01 Ag-11CM 3. 28E+00 2.4 4E+00 8. 11E+00 TM 04 58593 02/14/01 Ba-140 3. 47E+00 2.75E+00 9. 26E+00 TM 04 58593 02/14/01 Be-7 6. 63E+00 1.32E+01 4. 54E+01 TM 04 58593 02/14/01 Ce-141 2. 34E+00 2.22E+00 7. 39E+00 TM 04 58593 02/14/01 Ce-144 -1. 96E+00 7. 91E+00 2. 73E+01 TM 04 58593 02/14/01 Co-57 -0. 79E+00 1. 04E+00 3. 62E+00 TM 04 58593 02/14/01 Co-58 -4 .57E+00 1.58E+00 6. 49E+00 TM 04 58593 02/14/01 Co-60 3. 44E+00 2. 11E+00 6. 89E+00 TM 04 58593 02/14/01 Cr-51 -3. 10E+01 1. 42E+01 5. 22E+01 TM 04 58593 02/14/01 Cs-134 -2. 60E+00 1.86E+00 7. 05E+00 TM 04 58593 02/14/01 Cs-137 3. 90E+00 1. 96E+00 6. 32E+00 TM 04 58593 02/14/01 Fe-59 -7.78E+00 5. 13E+00 2. 03E+01 TM 04 58593 02/14/01 1-131 -2. 63E-02 7.14E-02 0. 57E+00 TM 04 58593 02/14/01 K-40 1. 42E+03 6. 69E+01 9.57E+01
- TM 04 58593 02/14/01 Mn-54 0. 69E+00 1.75E+00 6. 11E+00 TM 04 58593 02/14/01 Ru-103 -1. 67E+00 1.75E+00 6. 35E+00 TM 04 58593 02/14/01 Ru-106 1.72E+01 1. 60E+01 5. 38E+01 TM 04 58593 02/14/01 Sb-124 -0. 72E+00 4. 01E+00 1. 53E+01 TM 04 58593 02/14/01 Se-75 -1. 53E+00 2. O1E+00 7. 06E+00 TM 04 58593 02/14/01 Zn-65 1. 18E+00 9. 95E+00 3. 39E+01 TM 04 58593 02/14/01 Zr-95 -1.81E+00 2.89E+00 1. 06E+01
- Concentration Greater than 3 Standard Deviations 71
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 04 58995 03/14/01 Th-232 -4. 39E+00 6. 17E+00 2. 31E+01 TM 04 58995 03/14/01 Ag-IIOM 1. 31E+00 1.77E+00 6.21E+00 TM 04 58995 03/14/01 Ba-140 -0.44E+00 1. 77E+00 7. 18E+00 TM 04 58995 03/14/01 Be-7 1. 30E+00 1. 11E+01 3. 97E+01 TM 04 58995 03/14/01 Ce-141 -3. 69E+00 2. 39E+00 8. 62E+00 TM 04 58995 03/14/01 Ce-144 -7. 87E+00 8. 99E+00 3. 18E+01 TM 04 58995 03/14/01 Co-57 0. 65E+00 1. 15E+00 3. 90E+00 TM 04 58995 03/14/01 Co-58 -3. 27E+00 1. 33E+00 5 . 65E+00 TM 04 58995 03/14/01 Co-60 0. 44E+00 1. 8 6E+00 6.73E+00 TM 04 58995 03/14/01 Cr-51 -1. 12E+00 1. 37E+01 4 .83E+01 TM 04 58995 03/14/01 Cs-134 -6. 96E-02 1. 53E+00 5. 64E+00 TM 04 58995 03/14/01 Cs-137 2. 11E+00 1. 64E+00 5. 49E+00 TM 04 58995 03/14/01 Fe-59 -5 80E+00 5. 19E+00 2.02E+01 TM 04 58995 03/14/01 1-131 -2 . OOE-03 8. 1lE-02 0.59E+00 TM 04 58995 03/14/01 K-40 1. 43E+03 6. 57E+01 7.50E+01
- TM 04 58995 03/14/01 Mn-54 0. 72E+00 1. 39E+00 4 92E+00 TM 04 58995 03/14/01 Ru-103 -2. 11E+00 1. 33E+00 5.23E+00 TM 04 58995 03/14/01 Ru-106 1. 29E+01 1. 37E+01 4. 69E+01 TM 04 58995 03/14/01 Sb-124 4. 37E+00 2. 06E+00 5. 36E+00 TM 04 58995 03/14/01 Se-75 -2 . 07E+00 1. 86E+00 6.74E+00 TM 04 58995 03/14/01 Zn-65 -0. 95E+00 4. 07E+00 1. 49E+01 TM 04 58995 03/14/01 Zr-95 0. 90E+00 2. 09E+00 7 55E+00 TM 04 59441 04/11/01 Th-232 2. 88E+00 5. 90E+00 2. 08E+01 TM 04 59441 04/11/01 Ag-IIOM 0. 17E+00 1. 64E+00 6. 08E+00 TM 04 59441 04/11/01 Ba-140 -1. 58E+00 1. 98E+00 8 27E+00 TM 04 59441 04/11/01 Be-7 3. 89E+00 1. 17E+01 4. 12E+01 TM 04 59441 04/11/01 Ce-141 -4 67E+00 2. 29E+00 8. 39E+00 TM 04 59441 04/11/01 Ce-144 -2 44E+00 9. 15E+00 3. 18E+01 TM 04 59441 04/11/01 Co-57 1. 75E+00 1. 10E+00 3. 63E+00 TM 04 59441 04/11/01 Co-58 0. 55E+00 1. 44E+00 5 .14E+00 TM 04 59441 04/11/01 Co-60 -0. 64E+00 1. 32E+00 5 .30E+00 TM 04 59441 04/11/01 Cr-51 6. 74E+00 1. 32E+01 4. 55E+01 TM 04 59441 04/11/01 Cs-134 -0. 39E+00 1. 61E+00 5. 95E+00 TM 04 59441 04/11/01 Cs-137 2 42E+00 1. 55E+00 5. 11E+00 TM 04 59441 04/11/01 Fe-59 -6. 92E+00 4. 76E+00 1. 91E+01 TM 04 59441 04/11/01 1-131 2. 88E-02 0. 14E+00 0. 96E+00 TM 04 59441 04/11/01 K-40 1. 28E+03 6. 25E+01 7 .60E+01
- TM 04 59441 04/11/01 Mn-54 7. 1SE-02 1. 45E+00 5. 27E+00 TM 04 59441 04/11/01 Ru-103 -1. 95E+00 1 .40E+00 5 .40E+00 TM 04 59441 04/11/01 Ru-106 -4 .12E+00 1.27E+01 4. 69E+01 TM 04 59441 04/11/01 Sb-124 -0. 73E+00 2. 82E+00 1. 16E+01 TM 04 59441 04/11/01 Se-75 2.21E+00 1. 80E+00 6.02E+00 TM 04 59441 04/11/01 Zn-65 -5.68E+00 3. 54E+00 1.41E+01 TM 04 59441 04/11/01 Zr-95 2.4 4E+00 2. 68E+00 9.22E+00
- Concentration Greater than 3 Standard Deviations 72
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 04 59603 04/25/01 Th-232 -7. 73E+00 4. 21E+00 1. 67E+01 TM 04 59603 04/25/01 Ag-11CM 0 . 40E+00 1.59E+00 5. 70E+00 TM 04 59603 04/25/01 Ba-140 2. 57E+00 1.76E+00 5. 82E+00 TM 04 59603 04/25/01 Be-7 -4.13E+00 9. 13E+00 3. 36E+01 TM 04 59603 04/25/01 Ce-141 -3. 99E+00 2 .29E+00 8. 24E+00 TM 04 59603 04/25/01 Ce-144 -7. 22E+00 7. 97E+00 2. 82E+01 TM 04 59603 04/25/01 Co-57 -0. 18E+00 1 07E+00 3. 69E+00 TM 04 59603 04/25/01 Co-58 -0. 90E+00 1. 32E+00 4. 91E+00 TM 04 59603 04/25/01 Co-60 0. 58E+00 1. 16E+00 4. 17E+00 TM 04 59603 04/25/01 Cr-51 -2. 14E+01 1. 19E+01 4 .46E+01 TM 04 59603 04/25/01 Cs-134 1. 23E+00 1. 31E+00 4 47E+00 TM 04 59603 04/25/01 Cs-137 -1. 17E+00 1. 30E+00 4 .83E+00 TM 04 59603 04/25/01 Fe-59 -5. 72E+00 3. 65E+00 1. 4 6E+01 TM 04 59603 04/25/01 1-131 -9. 69E-03 8. 33E-02 0. 63E+00 TM 04 59603 04/25/01 K-40 1. 39E+03 5. 32E+01 5. 90E+01
- TM 04 59603 04/25/01 Mn-54 0. 28E+00 1. 07E+00 3. 84E+00 TM 04 59603 04/25/01 Ru-103 2. 10E+00 1.29E+00 4. 22E+00 TM 04 59603 04/25/01 Ru-106 -7. 85E+00 1.13E+01 4 16E+01 TM 04 59603 04/25/01 Sb-124 1. 02E+00 2. 56E+00 9.46E+00 TM 04 59603 04/25/01 Se-75 -1. 69E+00 1. 63E+00 5. 87E+00 TM 04 59603 04/25/01 Zn-65 -3. 88E+00 2.93E+00 1. 12E+01 TM 04 59603 04/25/01 Zr-95 -1.59E+00 1. 97E+00 7 . 52E+00 TM 04 59888 05/09/01 Th-232 3. 40E+00 6.84E+00 2.43E+01 TM 04 59888 05/09/01 Ag-IIOM -4 43E+00 2. 15E+00 9. 24E+00 TM 04 59888 05/09/01 Ba-140 1. 48E+00 2. 96E+00 1. 11E+01 TM 04 59888 05/09/01 Be-7 -2. 12E+01 1.30E+01 5. 19E+01 TM 04 59888 05/09/01 Ce-141 0. 21E+00 2. 63E+00 9. 12E+00 TM 04 59888 05/09/01 Ce-144 -8. 73E+00 9. 63E+00 3. 44E+01 TM 04 59888 05/09/01 Co-57 -0. 88E+00 1.20E+00 4.26E+00 TM 04 59888 05/09/01 Co-58 -2. 09E+00 1. 66E+00 6. 73E+00 TM 04 59888 05/09/01 Co-60 -1. 96E+00 2. 30E+00 9. 06E+00 TM 04 59888 05/09/01 Cr-51 -1. 10E+01 1. 60E+01 5. 85E+01 TM 04 59888 05/09/01 Cs-134 0 . OOE+00 1. 77E+00 6. 57E+00 TM 04 59888 05/09/01 Cs-137 0. 68E+00 1. 95E+00 6. 94E+00 TM 04 59888 05/09/01 Fe-59 3. 58E+00 5. 41E+00 1. 94E+01 TM 04 59888 05/09/01 1-131 6. 44E-02 0. 12E+00 0. 60E+00 TM 04 59888 05/09/01 K-40 1. 36E+03 7. 33E+01 7.48E+01
- TM 04 59888 05/09/01 Mn-54 1. 78E+00 1. 78E+00 6. 10E+00 TM 04 59888 05/09/01 Ru-103 -3. 38E+00 1. 87E+00 7.41E+00 TM 04 59888 05/09/01 Ru-106 0. 0OE+00 1. 37E+01 5. 05E+01 TM 04 59888 05/09/01 Sb-124 3. 11E+00 4. 27E+00 1.55E+01 TM 04 59888 05/09/01 Se-75 -2. 12E+00 2 17E+00 7.88E+00 TM 04 59888 05/09/01 Zn-65 0. 64E+00 3. 78E+00 1.40E+01 TM 04 59888 05/09/01 Zr-95 -3. 12E+00 2 89E+00 1. 16E+01
- Concentration Greater than 3 Standard Deviations 73
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 04 60114 05/23/01 Th-232 -0.76E+00 5.58E+00 2. 05E+01 TM 04 60114 05/23/01 Ag-IIOM 2. 63E+00 2. 06E+00 6. 93E+00 TM 04 60114 05/23/01 Ba-140 -1. 17E+00 2. 25E+00 9. 05E+00 TM 04 60114 05/23/01 Be-7 -1. 18E+01 1. 17E+01 4.42E+01 TM 04 60114 05/23/01 Ce-141 2.85E4-00 2 .4 6E+00 8. 19E+00 TM 04 60114 05/23/01 Ce-144 1. 41E+01 8. 51E+00 2.79E+01 TM 04 60114 05/23/01 Co-57 -0. 31E+00 1.06E+00 3. 71E+00 TM 04 60114 05/23/01 Co-58 -0. 53E+00 1.49E+00 5. 57E+00 TM 04 60114 05/23/01 Co-60 0. 34E+00 1 . 60E+00 5. 89E+00 TM 04 60114 05/23/01 Cr-51 -1. 16E+01 1.31E+01 4.78E+01 TM 04 60114 05/23/01 Cs-134 0. 89E+00 1.50E+00 5. 31E+00 TM 04 60114 05/23/01 Cs-137 2. 51E+00 1. 64E+00 5. 40E+00 TM 04 60114 05/23/01 Fe-59 2. 11E+00 4. 52E+00 1. 62E+01 TM 04 60114 05/23/01 1-131 0. 12E+00 0. 16E+00 0. 77E+00 TM 04 60114 05/23/01 K-40 1. 31E+03 6. 27E+01 7. 20E+01
- TM 04 60114 05/23/01 Mn-54 -2. 73E+00 1. 33E+00 5. 4 9E+00 TM 04 60114 05/23/01 Ru-103 -2. 16E+00 1. 44E+00 5. 57E+00 TM 04 60114 05/23/01 Ru-106 3.87E+00 1. 15E+01 4.13E+01 TM 04 60114 05/23/01 Sb-124 2. 95E+00 2. 56E+00 8.87E+00 TM 04 60114 05/23/01 Se-75 -0.70E+00 1. 85E+00 6. 55E+00 TM 04 60114 05/23/01 Zn-65 -8. 08E+00 3. 4 6E+00 1. 44E+01 TM 04 60114 05/23/01 Zr-95 0. 56E+00 2. 43E+00 8. 81E+00 TM 04 60417 06/06/01 Th-232 7. 97E+00 5. 95E+00 1. 99E+01 TM 04 60417 06/06/01 Ag-IIOM -2. 64E+00 1.74E+00 7. 15E+00 TM 04 60417 06/06/01 Ba-140 6. 23E+00 2.99E+00 9. 05E+00 TM 04 60417 06/06/01 Be-7 -2.84E+00 1. 33E+01 4 .82E+01 TM 04 60417 06/06/01 Ce-141 -6. 75E+00 2. 66E+00 9. 88E+00 TM 04 60417 06/06/01 Ce-144 4.23E+00 9. 08E+00 3. 09E+01 TM 04 60417 06/06/01 Co-57 -0. 34E+00 1. 15E+00 4. O1E+00 TM 04 60417 06/06/01 Co-58 -0. 51E+00 1. 63E+00 6. 05E+00 TM 04 60417 06/06/01 Co-60 1. 66E+00 1 .76E+00 6. 08E+00 TM 04 60417 06/06/01 Cr-51 9. 37E+00 1. 61E+01 5 . 54E+01 TM 04 60417 06/06/01 Cs-134 -3.45E+00 1. 55E+00 6. 42E+00 TM 04 60417 06/06/01 Cs-137 4 .17E+00 1. 57E+00 4.80E+00 TM 04 60417 06/06/01 Fe-59 -1. 54E+00 5. 74E+00 2. 13E+01 TM 04 60417 06/06/01 1-131 0. 64E+00 0 .29E+00 0. 91E+00 TM 04 60417 06/06/01 K-40 1. 35E+03 6. 50E+01 8.53E+01
- TM 04 60417 06/06/01 Mn-54 1. 45E+00 1 .23E+00 4.18E+00 TM 04 60417 06/06/01 Ru-103 -0. 92E+00 1. 59E+00 5. 91E+00 TM 04 60417 06/06/01 Ru-106 -1. 25E+01 1. 29E+01 4. 91E+01 TM 04 60417 06/06/01 Sb-124 1. 58E+00 3. 53E+00 1. 32E+01 TM 04 60417 06/06/01 Se-75 3. 31E+00 1. 88E+00 6. 15E+00 TM 04 60417 06/06/01 Zn-65 -1. 93E+00 3. 80E+00 1. 42E+01 TM 04 60417 06/06/01 Zr-95 -i .80E+00 2. 59E+00 9. 95E+00 Concentration Greater than 3 Standard Deviations 74
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 04 60614 06/20/01 Th-232 1. 40E+01 6.73E+00 2. 14E+01 TM 04 60614 06/20/01 Ag-IIOM -0.41E+00 1.70E+00 6.51E+00 TM 04 60614 06/20/01 Ba-140 -1.70E+00 2.33E+00 9. 92E+00 TM 04 60614 06/20/01 Be-7 2. 90E+00 1. 41E+01 4. 97E+01 TM 04 60614 06/20/01 Ce-141 0.81E+00 2. 87E+00 9. 80E+00 TM 04 60614 06/20/01 Ce-144 4.74E+00 9. 95E+00 3. 39E+01 TM 04 60614 06/20/01 Co-57 2. 04E+00 1. 33E+00 4. 39E+00 TM 04 60614 06/20/01 Co-58 -1. 82E+00 1. 62E+00 6. 31E+00 TM 04 60614 06/20/01 Co-60 -1. 44E+00 1. 66E+00 6. 62E+00 TM 04 60614 06/20/01 Cr-51 -5. 29E+00 1.53E+01 5. 47E+01 TM 04 60614 06/20/01 Cs-134 1.41E+00 1. 60E+00 S. 53E+00 TM 04 60614 06/20/01 Cs-137 3. 11E+00 1 .70E+00 5. 51E+00 TM 04 60614 06/20/01 Fe-59 -6. 94E+00 5. 31E+00 2. 12E+01 TM 04 60614 06/20/01 1-131 -7. 21E-02 6. 65E-02 0. 45E+00 TM 04 60614 06/20/01 K-40 1.26E+03 6. 41E+01 7.96E+01
- TM 04 60614 06/20/01 Mn-54 0. 69E+00 1. 41E+00 5. 02E+00 TM 04 60614 06/20/01 Ru-103 -3. 89E+00 1. 67E+00 6. 66E+00 TM 04 60614 06/20/01 Ru-106 -1. 18E+01 1. 39E+01 S. 24E+01 TM 04 60614 06/20/01 Sb-124 7 .29E+00 3. 34E+00 9. 73E+00 TM 04 60614 06/20/01 Se-75 1. 95E+00 1. 90E+00 6.41E+00 TM 04 60614 06/20/01 Zn-65 5. 12E+00 8. 75E+00 2. 97E+01 TM 04 60614 06/20/01 Zr-95 1. 33E+00 2. 67E+00 9. 50E+00 TM 04 60912 07 /11/01 Th-232 4. 33E+00 5. 53E+00 1. 92E+01 TM 04 60912 07 /11/01 Ag-IIOM 2. 73E+00 1. 91E+00 6.35E+00 TM 04 60912 07 /11/01 Ba-140 1. 25E+00 1.78E+00 6. 54E+00 TM 04 60912 07 /11/01 Be-7 -7 88E+00 1. 12E+01 4. 17E+01 TM 04 60912 07 /11/01 Ce-141 -2. 33E+00 2. 48E+00 8.78E+00 TM 04 60912 07 /11/01 Ce-144 1. 01E+01 9. 25E+00 3. 09E+01 TM 04 60912 07 /11/01 Co-57 -0. 14E+00 1. 14E+00 3. 94E+00 TM 04 60912 07 /11/01 Co-58 0. 00E+00 1. 4 6E+00 5. 35E+00 TM 04 60912 07 /11/01 Co-60 -1. 39E+00 1. 61E+00 6. 4 1E+00 TM 04 60912 07 /11/01 Cr-51 2. 07E+01 1. 45E+01 4 80E+01 TM 04 60912 07 /11/01 Cs-134 -0. 71E+00 1. 4 9E+00 5. 64E+00 TM 04 60912 07 /11/01 Cs-137 3. 22E+00 1. 85E+00 6. 02E+00 TM 04 60912 07 /11/01 Fe-59 1. 14E+00 4 .82E+00 1. 75E+01 TM 04 60912 07 /11/01 1-131 -1. 48E-02 6. 75E-02 0. 42E+00 TM 04 60912 07 /11/01 K-40 1. 40E+03 6. 44E+01 6. 80E+01
- TM 04 60912 07 /11/01 Mn-54 -0. 36E+00 1. 38E+00 5. 15E+00 TM 04 60912 07 /11/01 Ru-103 -0. 83E+00 1. 53E+00 5. 61E+00 TM 04 60912 07/11/01 Ru-106 2. 06E+01 1. 28E+01 4.21E+01 TM 04 60912 07/11/01 Sb-124 3.69E+00 3. 38E+00 1. 17E+01 TM 04 60912 07/11/01 Se-75 0. 69E+00 1. 92E+00 6. 61E+00 TM 04 60912 07/11/01 Zn-65 1. 90E+00 5. 37E+00 1.84E+01 TM 04 60912 07/11/01 Zr-95 1. 34E+00 2. 24E+00 7. 94E+00
- Concentration Greater than 3 Standard Deviations 75
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 04 61169 07/25/01 Th-232 1. 09E+01 6. 62E+00 2. 17E+01 TM 04 61169 07/25/01 Ag-11GM -1. 73E+00 1. 81E+00 7. 12E+00 TM 04 61169 07/25/01 Ba-140 -1. 50E+00 1. 15E+00 5. 84E+00 TM 04 61169 07/25/01 Be-7 -1. 30E+01 1. 19E+01 4 .49E+01 TM 04 61169 07/25/01 Ce-141 -4. 36E+00 2. 35E+00 8. 54E+00 TM 04 61169 07/25/01 Ce-144 4.25E+00 9. 11E+00 3. 10E+01 TM 04 61169 07/25/01 Co-57 -0. 79E+00 1. 16E+00 4. 08E+00 TM 04 61169 0,7/25/01 Co-58 -1. OOE+00 1. 38E+00 5. 30E+00 TM 04 61169 07/25/01 Co-60 1. 56E+00 1. 47E+00 5. 09E+00 TM 04 61169 07/25/01 Cr-51 9. OOE+00 1. 44E+01 4. 93E+01 TM 04 61169 07/25/01 Cs-134 0. 84E+00 1. 45E+00 5. 14E+00 TM 04 61169 07/25/01 Cs-137 3. 64E+00 1. 82E+00 5. 85E+00 TM 04 61169 07/25/01 Fe-59 -4. 59E+00 4. 57E+00 1. 80E+01 TM 04 61169 07/25/01 1-131 0. 17E+00 0. 12E+00 0 49E+00 TM 04 61169 07/25/01 K-40 1. 38E+03 6. 42E+01 7.OOE+01
- TM 04 61169 07/25/01 Mn-54 -0. 60E+00 1. 32E+00 4. 99E+00 TM 04 61169 07/25/01 Ru-103 -1.4 6E+00 1. 12E+00 4 45E+00 TM 04 61169 07/25/01 Ru-106 8. 23E+00 1. 05E+01 3. 65E+01 TM 04 61169 07/25/01 Sb-124 4.37E+00 3. 57E+00 1. 22E+01 TM 04 61169 07/25/01 Se-75 -0.28E+00 1. 74E+00 6. 13E+00 TM 04 61169 07/25/01 Zn-65 1. 42E+00 4 . 10E+00 1. 45E+01 TM 04 61169 07/25/01 Zr-95 -1.54E+00 2. 21E+00 8 . 57E+00 TM 04 61368 08/08/01 Th-232 -2 . 38E+00 6. 56E+00 2 48E+01 TM 04 61368 08/08/01 Ag-IIOM -1. 46E+00 2. 53E+00 9. 65E+00 TM 04 61368 08/08/01 Ba-140 -1 79E+00 2. 31E+00 9. 92E+00 TM 04 61368 08/08/01 Be-7 -1. 1E+01 1. 35E+01 5. 19E+01 TM 04 61368 08/08/01 Ce-141 3. 85E+00 2. 36E+00 7 .75E+00 TM 04 61368 08/08/01 Ce-144 1. 06E+01 9. 11E+00 3. 05E+01 TM 04 61368 08/08/01 Co-57 -1. 45E+00 1. 11E+00 4. 03E+00 TM 04 61368 08/08/01 Co-58 0. 85E+00 1. 51E+00 5 41E+00 TM 04 61368 08/08/01 Co-60 -2 14E+00 1. 99E+00 8. 15E+00 TM 04 61368 08/08/01 Cr-51 -8. 53E+00 1. 60E+01 5. 76E+01 TM 04 61368 08/08/01 Cs-134 0. 11E+00 1. 87E+00 6. 90E+00 TM 04 61368 08/08/01 Cs-137 4 49E+00 2. 12E+00 6.73E+00 TM 04 61368 08/08/01 Fe-59 -3. 37E+00 4. 87E+00 1. 95E+01 TM 04 61368 08/08/01 1-131 3. 12E-02 0. 11E+00 0. 73E+00 TM 04 61368 08/08/01 K-40 1. 17E+03 6.87E+01 7 .70E+01
- TM 04 61368 08/08/01 Mn-54 0. 25E+00 1. 80E+00 6.54E+00 TM 04 61368 08/08/01 Ru-103 -2. 73E+00 1. 59E+00 6.35E+00 TM 04 61368 08/08/01 Ru-106 -1.34E+00 1. 49E+01 5. 49E+01 TM 04 61368 08/08/01 Sb-124 -1. 98E+00 2. 79E+00 1 .30E+01 TM 04 61368 08/08/01 Se-75 -4 .15E+00 2 OOE+00 7. 61E+00 TM 04 61368 08/08/01 Zn-65 -1. 14E+01 4. 29E+00 1. 83E+01 TM 04 61368 08/08/01 Zr-95 -0. 84E+00 2. 30E+00 9. 05E+00
- Concentration Greater than 3 Standard Deviations 76
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 04 61548 08/22/01 Th-232 3. 40E+00 6. 84E+00 2. 43E+01 TM 04 61548 08/22/01 Ag-liOM -2. 59E+00 2. 65E+00 1. 03E+01 TM 04 61548 08/22/01 Ba-140 0.78E+00 3. 23E+00 1. 24E+01 TM 04 61548 08/22/01 Be-7 0. OOE+00 1.26E+01 4. 64E+01 TM 04 61548 08/22/01 Ce-141 5. 05E+00 2.78E+00 9. 06E+00 TM 04 61548 08/22/01 Ce-144 2. 56E+00 9. 38E+00 3. 23E+01 TM 04 61548 08/22/01 Co-57 0. 83E+00 1.29E+00 4. 38E+00 TM 04 61548 08/22/01 Co-58 1. 07E+00 1. 78E+00 6. 33E+00 TM 04 61548 08/22/01 Co-60 2. 73E+00 1. 50E+00 4.69E+00 TM 04 61548 08/22/01 Cr-51 2. 58E+01 1.74E+01 5. 75E+01 TM 04 61548 08/22/01 Cs-134 -0. 74E+00 1. 82E+00 6. 93E+00 TM 04 61548 08/22/01 Cs-137 3. 4 1E+00 1. 82E+00 5. 83E+00 TM 04 61548 08/22/01 Fe-59 -1. 04E+01 5. 95E+00 2.50E+01 TM 04 61548 08/22/01 1-131 2 . 90E-02 0. 13E+00 0.80E+00 TM 04 61548 08/22/01 K-40 1.32E+03 7. 29E+01 8.18E+01
- TM 04 61548 08/22/01 Mn-54 -1. 53E+00 1. 80E+00 6. 96E+00 TM 04 61548 08/22/01 Ru-103 -0. 69E+00 1. 96E+00 7.21E+00 TM 04 61548 08/22/01 Ru-106 -1. 15E+01 1. 64E+01 6. 18E+01 TM 04 61548 08/22/01 Sb-124 0 . OOE+00 3. 31E+00 1.37E+01 TM 04 61548 08/22/01 Se-75 4.27E+00 2. 16E+00 7 . OOE+00 TM 04 61548 08/22/01 Zn-65 -7. 05E+00 4. 30E+00 1.75E+01 TM 04 61548 08/22/01 Zr-95 -2 . 02E+00 2. 69E+00 1. 07E+01 TM 04 61797 09/05/01 Th-232 -6. 23E+00 7. 10E+00 2. 73E+01 TM 04 61797 09/05/01 Ag-11OM 3. 29E+00 2. 50E+00 8. 40E+00 TM 04 61797 09/05/01 Ba-140 1. 19E+00 2. 38E+00 8. 95E+00 TM 04 61797 09/05/01 Be-7 -3. 85E+01 1. 35E+01 5. 62E+01 TM 04 61797 09/05/01 Ce-141 0. 62E+00 2. 71E+00 9. 30E+00 TM 04 61797 09/05/01 Ce-144 8. 64E+00 1.03E+01 3. 48E+01 TM 04 61797 09/05/01 Co-57 1. 14E+00 1. 35E+00 4. 55E+00 TM 04 61797 09/05/01 Co-58 1. 45E+00 1. 89E+00 6. 58E+00 TM 04 61797 09/05/01 Co-60 0. 86E+00 2. 10E+00 7. 65E+00 TM 04 61797 09/05/01 Cr-51 4. 27E+00 1. 63E+01 5. 68E+01 TM 04 61797 09/05/01 Cs-134 -0.4 9E+00 1.79E+00 6.79E+00 TM 04 61797 09/05/01 Cs-137 0. 92E+00 1. 97E+00 6. 93E+00 TM 04 61797 09/05/01 Fe-59 0.70E+00 6. 15E+00 2. 26E+01 TM 04 61797 09/05/01 1-131 0. 37E+00 0. 20E+00 0. 68E+00 TM 04 61797 09/05/01 K-40 1. 20E+03 7. 01E+01 8.57E+01
- TM 04 61797 09/05/01 Mn-54 0. 50E+00 1. 74E+00 6. 30E+00 TM 04 61797 09/05/01 Ru-103 -1. 68E+00 1. 60E+00 6. 19E+00 TM 04 61797 09/05/01 Ru-106 -7. 38E+00 1. 45E+01 5. 49E+01 TM 04 61797 09/05/01 Sb-124 2. 96E+00 3.56E+00 1. 30E+01 TM 04 61797 09/05/01 Se-75 0. 69E+00 2.34E+00 8. 09E+00 TM 04 61797 09/05/01 Zn-65 0. 62E+00 1.07E+01 3. 69E+01 TM 04 61797 09/05/01 Zr-95 0. 39E+00 2. 80E+00 1. 03E+01
- Concentration Greater than 3 Standard Deviations 77
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 04 61982 09/19/01 Th-232 4. 33E+00 6.25E+00 2. 17E+01 TM 04 61982 09/19/01 Ag-IIOM 0. 48E+00 1 .70E+00 6. 21E+00 TM 04 61982 09/19/01 Ba-140 0. 40E+00 1.79E+00 6. 92E+00 TM 04 61982 09/19/01 Be-7 6. 50E+00 1. 06E+01 3. 72E+01 TM 04 61982 09/19/01 Ce-141 -3. 65E+00 2. 25E+00 8. 18E+00 TM 04 61982 09/19/01 Ce-144 3. 62E+00 8. 61E+00 2. 94E+01 TM 04 61982 09/19/01 Co-57 -0. 64E+00 1. 11E+00 3. 91E+00 TM 04 61982 09/19/01 Co-58 0. 95E+00 1. 28E+00 4 .4 9E+00 TM 04 61982 09/19/01 Co-60 -2. 13E+00 1. 86E+00 7. 34E+00 TM 04 61982 09/19/01 Cr-51 2. 60E+01 1. 32E+01 4. 27E+01 TM 04 61982 09/19/01 Cs-134 3. 07E+00 1. 51E+00 4. 77E+00 TM 04 61982 09/19/01 Cs-137 -0 58E+00 1.42E+00 5. 30E+00 TM 04 61982 09/19/01 Fe-59 7 63E+00 4. 87E+00 1. 60E+01 TM 04 61982 09/19/01 1-131 9. 01E-02 0. 14E+00 0. 71E+00 TM 04 61982 09/19/01 K-40 1. 32E+03 6.39E+01 8. 13E+01
- TM 04 61982 09/19/01 Mn-54 0. 17E+00 1. 37E+00 4. 99E+00 TM 04 61982 09/19/01 Ru-103 -0. 16E+00 1.35E+00 4. 93E+00 TM 04 61982 09/19/01 Ru-106 -3. 86E+00 1. 10E+01 4 12E+01 TM 04 61982 09/19/01 Sb-124 1. 46E+00 2.73E+00 1.03E+01 TM 04 61982 09/19/01 Se-75 1. 66E+00 1.81E+00 6. 13E+00 TM 04 61982 09/19/01 Zn-65 -5. 69E+00 3. 42E+00 1.38E+01 TM 04 61982 09/19/01 Zr-95 -1. 89E+00 2. 51E+00 9. 61E+00 TM 04 62462 10/17/01 Th-232 2.44E+00 4. 27E+00 1. 73E+01 TM 04 62462 10/17/01 Ag-lIOM 0. 40E+00 1. 63E+00 5. 82E+00 TM 04 62462 10/17/01 Ba-140 -1. 27E+00 1. 90E+00 7.44E+00 TM 04 62462 10/17/01 Be-7 1. 10E+01 1. 01E+01 3. 42E+01 TM 04 62462 10/17/01 Ce-141 -0. 83E+00 2. 18E+00 7. 57E+00 TM 04 62462 10/17/01 Ce-144 2. 75E+00 8 16E+00 2. 78E+01 TM 04 62462 10/17/01 Co-57 -0. 30E+00 1. 04E+00 3. 61E+00 TM 04 62462 10/17/01 Co-58 -0. 87E+00 1. 36E+00 5. 03E+00 TM 04 62462 10/17/01 Co-60 -0.4 1E+00 1. 25E+00 4.73E+00 TM 04 62462 10/17/01 Cr-51 1.36E+01 1. 16E+01 3. 88E+01 TM 04 62462 10/17/01 Cs-134 0. 31E+00 1. 41E+00 5. 00E+00 TM 04 62462 10/17/01 Cs-137 4. 12E+00 1. 55E+00 4 .83E+00 TM 04 62462 10/17/01 Fe-59 -2. 38E+00 3. 36E+00 1.29E+01 TM 04 62462 10/17/01 1-131 6. 05E-03 8. 16E-02 0. 58E+00 TM 04 62462 10/17/01 K-40 1.4 6E+03 5.41E+01 5.46E+01
- TM 04 62462 10/17/01 Mn-54 0. 55E+00 1.26E+00 4 . 4 1E+00 TM 04 62462 10/17/01 Ru-103 -1.75E+00 1. 28E+00 4 .82E+00 TM 04 62462 10/17/01 Ru-106 8. 00E+00 1. 13E+01 3. 90E+01 TM 04 62462 10/17/01 Sb-124 -2.42E+00 3. 09E+00 1. 21E+01 TM 04 62462 10/17/01 Se-75 3. 65E+00 1. 67E+00 5. 37E+00 TM 04 62462 10/17/01 Zn-65 -3.48E+00 3 . 54E+00 1.31E+01 TM 04 62462 10/17/01 Zr-95 0 . 66E+00 2. 20E+00 7. 79E+00
- Concentration Greater than 3 Standard Deviations 78
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 04 62935 11/14/01 Th-232 -6. 03E+00 6.62E+00 2. 48E+01 TM 04 62935 11/14/01 Ag-IIOM 1. 42E+00 2. 15E+00 7. 50E+00 TM 04 62935 11/14/01 Ba-140 -1. 02E+00 2. 35E+00 9. 30E+00 TM 04 62935 11/14/01 Be-7 -7V.88E+00 1.39E+01 5. 05E+01 TM 04 62935 11/14/01 Ce-141 -1. 28E+00 3. 12E+00 1. 08E+01 TM 04 62935 11/14/01 Ce-144 -1. 38E+01 1. 13E+01 3. 99E+01 TM 04 62935 11/14/01 Co-57 1. 96E+00 1. 50E+00 4. 97E+00 TM 04 62935 11/14/01 Co-58 2. 22E+00 1. 62E+00 5. 42E+00 TM 04 62935 11/14/01 Co-60 1. 62E+00 1.76E+00 6. 08E+00 TM 04 62935 11/14/01 Cr-51 -2. 30E+00 1.41E+01 4. 98E+01 TM 04 62935 11/14/01 Cs-134 1. 29E+00 1.58E+00 5. 47E+00 TM 04 62935 11/14/01 Cs-137 0. 74E+00 1.70E+00 5. 97E+00 TM 04 62935 11/14/01 Fe-59 3. 51E+00 4. 71E+00 1. 65E+01 TM 04 62935 11/14/01 1-131 0. 16E+00 0. 18E+00 0. 84E+00 TM 04 62935 11/14/01 K-40 1. 20E+03 6. 07E+01 7.40E+01
- TM 04 62935 11/14/01 Mn-54 -1.4 6E+00 1. 50E+00 5. 76E+00 TM 04 62935 11/14/01 Ru-103 -0. 50E+00 1. 58E+00 5. 73E+00 TM 04 62935 11/14/01 Ru-106 -1. 86E+01 1.31E+01 5. 08E+01 TM 04 62935 11/14/01 Sb-124 7. 37E-02 3. 37E+00 1. 31E+01 TM 04 62935 11/14/01 Se-75 -0.49E+00 2. 12E+00 7. 39E+00 TM 04 62935 11/14/01 Zn-65 -5. 18E+00 4.15E+00 1. 59E+01 TM 04 62935 11/14/01 Zr-95 3.4 6E+00 2.45E+00 8. 15E+00 TM 04 63301 12/12/01 Th-232 -4. 75E+00 6. 88E+00 2. 54E+01 TM 04 63301 12/12/01 Ag-IlOM -0.4 8E+00 2. 31E+00 8.4 4E+00 TM 04 63301 12/12/01 Ba-140 -0. 66E+00 2. 53E+00 9. 69E+00 TM 04 63301 12 /12/01 Be-7 -3. 89E+00 1. 30E+01 4.70E+01 TM 04 63301 12/12/01 Ce-141 2.51E+00 2. 92E+00 9. 7 9E+00 TM 04 63301 12/12/01 Ce-144 1. 16E+01 1. 10E+01 3. 67E+01 TM 04 63301 12/12/01 Co-57 2. 18E+00 1. 52E+00 5. 01E+00 TM 04 63301 12/12/01 Co-58 -0. 60E+00 1. 66E+00 6. 11E+00 TM 04 63301 12/12/01 Co-60 0.00E+00 1. 75E+00 6. 50E+00 TM 04 63301 12/12/01 Cr-51 -1. 87E+00 1. 49E+01 5. 22E+01 TM 04 63301 12/12/01 Cs-134 1.29E+00 1. 71E+00 5. 94E+00 TM 04 63301 12/12/01 Cs-137 2. 57E+00 1. 66E+00 5. 48E+00 TM 04 63301 12/12/01 Fe-59 6.91E+00 5. 36E+00 1.80E+01 TM 04 63301 12/12/01 1-131 5. 50E-02 0. 13E+00 0. 70E+00 TM 04 63301 12/12/01 K-40 1 .25E+03 6. 25E+01 8.24E+01
- TM 04 63301 12/12/01 Mn-54 0. 29E+00 1. 58E+00 5. 65E+00 TM 04 63301 12/12/01 Ru-103 -0. 81E+00 1. 57E+00 5. 73E+00 TM 04 63301 12/12/01 Ru-106 6. 17E+00 1. 20E+01 4. 22E+01 TM 04 63301 12/12/01 Sb-124 -2. 91E+00 3. 18E+00 1.35E+01 TM 04 63301 12/12/01 Se-75 3. 29E+00 2. 20E+00 7. 27E+00 TM 04 63301 12/12/01 Zn-65 -4. 97E+00 3. 86E+00 1.50E+01 TM 04 63301 12/12/01 Zr-95 0. 34E+00 2. 72E+00 9. 80E+00
- Concentration Greater than 3 Standard Deviations 79
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 09 58092 01/10/01 Th-232 -4 .15E+00 4.39E+00 1. 67E+01 TM 09 58092 01/10/01 Ag-11GM -0.41E+00 1. 67E+00 6. 14E+00 TM 09 58092 01/10/01 Ba-140 -0.76E+00 1. 62E+00 6. 63E+00 TM 09 58092 01/10/01 Be-7 1. 06E+00 1.00E+01 3. 57E+01 TM 09 58092 01/10/01 Ce-141 -2. 26E+00 2.14E+00 7. 64E+00 TM 09 58092 01/10/01 Ce-144 3. 16E+00 7. 92E+00 2.70E+01 TM 09 58092 01/10/01 Co-57 1. 02E-02 1 .00E+00 3. 47E+00 TM 09 58092 01/10/01 Co-58 -0. 42E+00 1.12E+00 4. 21E+00 TM 09 58092 01/10/01 Co-60 1. 35E+00 1.30E+00 4.44E+00 TM 09 58092 01/10/01 Cr-51 -6. 98E+00 1. 23E+01 4.42E+01 TM 09 58092 01/10/01 Cs-134 -0. 32E+00 1. 27E+00 4. 67E+00 TM 09 58092 01/10/01 Cs-137 3.4 6E+00 1. 41E+00 4.43E+00 TM 09 58092 01/10/01 Fe-59 0. 85E+00 4. 26E+00 1. 53E+01 TM 09 58092 01/10/01 1-131 9. 85E-02 0. 12E+00 0. 61E+00 TM 09 58092 01/10/01 K-40 1.46E+03 5. 49E+01 5.45E+01
- TM 09 58092 01/ 10/0 1 Mn-54 -0.86E+00 1. 21E+00 4. 53E+00 TM 09 58092 01/10/01 Ru-103 0. 54E+00 1. 28E+00 4. 50E+00 TM 09 58092 01 /10/01 Ru-106 5. 53E+00 9. 94E+00 3.4 8E+01 TM 09 58092 01 /10/01 Sb-124 -2. 12E+00 2.49E+00 1.03E+01 TM 09 58092 01 /10/01 Se-75 -0. 12E+00 1. 67E+00 5.82E+00 TM 09 58092 01 /10/01 Zn-65 -4.84E+00 3.24E+00 1.24E+01 TM 09 58092 01 /10/01 Zr-95 0. 43E+00 2. 11E+00 7. 59E+00 TM 09 58594 02/14/01 Th-232 -8. 20E+00 7. 65E+00 2 .94E+01 TM 09 58594 02/14/01 Ag-IlOM -0. 73E+00 2. 20E+00 8 .44E+00 TM 09 58594 02/14/01 Ba-140 -0. 60E+00 1. 98E+00 8 .42E+00 TM 09 58594 02/14/01 Be-7 0. OOE+00 1. 43E+01 5. 15E+01 TM 09 58594 02/14/01 Ce-141 1. 98E+00 2. 66E+00 9.01E+00 TM 09 58594 02/14/01 Ce-144 1. 37E+01 1. 02E+01 3. 37E+01 TM 09 58594 02/14/01 Co-57 -0. 85E+00 1 .34E+00 4. 71E+00 TM 09 58594 02/14/01 Co-58 -2. 7 1E+00 1. 91E+00 7 .58E+00 TM 09 58594 02/14/01 Co-60 -1. 23E+00 1.75E+00 7. 16E+00 TM 09 58594 02/14/01 Cr-51 2. 43E+01 1.51E+01 4. 94E+01 TM 09 58594 02/14/01 Cs-134 0. 14E+00 1. 63E+00 6.08E+00 TM 09 58594 02/14/01 Cs-137 2. 34E+00 2. 10E+00 7. 10E+00 TM 09 58594 02/14/01 Fe-59 1. 52E+00 6. 40E+00 2. 32E+01 TM 09 58594 02/14/01 1-131 4 .82E-02 7.87E-02 0. 44E+00 TM 09 58594 02/14/01 K-40 1. 20E+03 6. 94E+01 7. 49E+01
- TM 09 58594 02/14/01 Mn-54 0. OOE+00 1. 83E+00 6. 69E+00 TM 09 58594 02/14/01 Ru-103 0. 21E+00 1.70E+00 6. 13E+00 TM 09 58594 02/14/01 Ru-106 -2. 50E+01 1.48E+01 5 95E+01 TM 09 58594 02/14/01 Sb-124 1. 99E+00 3.4 4E+00 1.30E+01 TM 09 58594 02/14/01 Se-75 -1. 91E+00 2.37E+00 8. 51E+00 TM 09 58594 02/14/01 Zn-65 -1. 14E+01 4.49E+00 1. 90E+01 TM 09 58594 02/14/01 Zr-95 -2. 60E+00 3. 60E+00 1.36E+01
- Concentration Greater than 3 Standard Deviations 80
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 09 58996 03/14/01 Th-232 -2. 01E+00 4. 26E+00 1. 59E+01 TM 09 58996 03/14/01 Ag-IIOM 1. 63E+00 1 68E+00 5. 74E+00 TM 09 58996 03/14/01 Ba-140 0. 31E+00 1 65E+00 6. 16E+00 TM 09 58996 03/14/01 Be-7 -1. 82E+01 1. 07E+01 4. 06E+01 TM 09 58996 03/14/01 Ce-141 -1. 50E+00 2 . 07E+00 7. 30E+00 TM 09 58996 03/14/01 Ce-144 1. OOE+01 7. 88E+00 2. 62E+01 TM 09 58996 03/14/01 Co-57 -1. 06E+00 1. 02E+00 3. 61E+00 TM 09 58996 03/14/01 Co-58 1. 22E+00 1. 19E+00 4. 04E+00 TM 09 58996 03/14/01 Co-60 0. 65E+00 1. 41E+00 5. 00E+00 TM 09 58996 03/14/01 Cr-51 -2. 25E+01 1. 15E+01 4 31E+01 TM 09 58996 03/14/01 Cs-134 0. 18E+00 1. 18E+00 4 .27E+00 TM 09 58996 03/14/01 Cs-137 3. 85E+00 1. 61E+00 5. 09E+00 TM 09 58996 03/14/01 Fe-59 -2. 65E+00 3. 79E+00 1. 43E+01 TM 09 58996 03/14/01 1-131 0. 12E+00 0. 13E+00 0. 57E+00 TM 09 58996 03/14/01 K-40 1. 39E+03 5. 37E+01 5. 43E+01
- TM 09 58996 03/14/01 Mn-54 0. 28E+00 1. 30E+00 4 60E+00 TM 09 58996 03/14/01 Ru-103 -2. 90E+00 1. 30E+00 5. 07E+00 TM 09 58996 03/14/01 Ru-106 -1. 57E+00 1. 05E+01 3. 80E+01 TM 09 58996 03/14/01 Sb-124 5. 06E+00 2. 37E+00 7 . 14E+00 TM 09 58996 03/14/01 Se-75 0 45E+00 1. 56E+00 5. 38E+00 TM 09 58996 03/14/01 Zn-65 -6. 50E+00 2. 88E+00 1. 16E+01 TM 09 58996 03/14/01 Zr-95 -2. 24E+00 2. 19E+00 8 33E+00 TM 09 59442 04/11/01 Th-232 1. 68E+01 6.84E+00 2. 08E+01 TM 09 59442 04/11/01 Ag-IIOM -3. 70E+00 2. 34E+00 9. 60E+00 TM 09 59442 04/11/01 Ba-140 0. 60E+00 2.16E+00 8.45E+00 TM 09 59442 04/11/01 Be-7 -1. 86E+01 1.30E+01 5.12E+01 TM 09 59442 04/11/01 Ce-141 3. 48E+00 2. 63E+00 8. 75E+00 TM 09 59442 04/11/01 Ce-144 1.78E+01 9. 90E+00 3. 24E+01 TM 09 59442 04/11/01 Co-57 1. 05E+00 1.21E+00 4. 08E+00 TM 09 59442 04/11/01 Co-58 -6. 65E-02 1. 86E+00 6. 86E+00 TM 09 59442 04/11/01 Co-60 -2. 53E+00 1. 98E+00 8.24E+00 TM 09 59442 04/11/01 Cr-51 -1. 44E+00 1. 60E+01 5. 67E+01 TM 09 59442 04/11/01 Cs-134 3. 27E+00 1. 89E+00 6. 12E+00 TM 09 59442 04/11/01 Cs-137 0. 69E+00 1. 98E+00 7. 02E+00 TM 09 59442 04/11/01 Fe-59 -4.81E+00 5.59E+00 2. 22E+01 TM 09 59442 04 /11/01 1-131 3. 54E-02 0. 14E+00 0. 96E+00 TM 09 59442 04 /11/01 K-40 1. 08E+03 6. 76E+01 8.92E+01
- TM 09 59442 04 /11/01 Mn-54 2. 80E+00 1.46E+00 4.62E+00 TM 09 59442 04/11/01 Ru-103 1.06E+00 1.71E+00 5.99E+00 TM 09 59442 04 /11/01 Ru-106 -1. 36E+00 1.51E+01 5.56E+01 TM 09 59442 04/11/01 Sb-124 2. 00E+00 3. 16E+00 1.20E+01 TM 09 59442 04/11/01 Se-75 0. OOE+00 2.15E+00 7. 55E+00 TM 09 59442 04/11/01 Zn-65 -7. 67E+00 4.24E+00 1. 75E+01 TM 09 59442 04/11/01 Zr-95 3. 59E+00 2. 60E+00 8.67E+00
- Concentration Greater than 3 Standard Deviations 81
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 09 59604 04/25/01 Th-232 8. 49E+00 4.51E+00 1. 46E+01 TM 09 59604 04/25/01 Ag-110M 2 . 28E+00 1. 37E+00 4.48E+00 TM 09 59604 04/25/01 Ba-140 -1. 41E+00 1.79E+00 7. 29E+00 TM 09 59604 04/25/01 Be-7 -1. 96E+00 8. 86E+00 3. 22E+01 TM 09 59604 04/25/01 Ce-141 -0. 10E+00 2.42E+00 8. 31E+00 TM 09 59604 04/25/01 Ce-144 2. 32E+01 9. 09E+00 2. 92E+01 TM 09 59604 04/25/01 Co-57 0. 61E+00 1.20E+00 4. 04E+00 TM 09 59604 04/25/01 Co-58 3. 56E-02 1. 18E+00 4. 27E+00 TM 09 59604 04/25/01 Co-60 0.25E+00 1. 28E+00 4. 64E+00 TM 09 59604 04/25/01 Cr-51 -2. 57E+01 1. 18E+01 4.45E+01 TM 09 59604 04/25/01 Cs-134 1.29E+00 1. 12E+00 3. 79E+00 TM 09 59604 04/25/01 Cs-137 0. 15E+00 1.22E+00 4. 32E+00 TM 09 59604 04/25/01 Fe-59 -1. 15E+00 3. 82E+00 1.4 1E+01 TM 09 59604 04/25/01 1-131 0. 10E+00 0. 12E+00 0. 57E+00 TM 09 59604 04/25/01 K-40 1.42E+03 5. 17E+01 4.60E+01
- TM 09 59604 04/25/01 Mn-54 -0.7 9E+00 0. 90E+00 3. 50E+00 TM 09 59604 04/25/01 Ru-103 -0. 37E+00 1. 19E+00 4. 31E+00 TM 09 59604 04/25/01 Ru-106 1. 33E+01 9. 16E+00 3 . 04E+01 TM 09 59604 04/25/01 Sb-124 4. 92E+00 2 41E+00 7 . 38E+00 TM 09 59604 04/25/01 Se-75 -2. 55E+00 1. 67E+00 6. 03E+00 TM 09 59604 04/25/01 Zn-65 -1. 28E+00 2. 83E+00 1. 04E+01 TM 09 59604 04/25/01 Zr-95 2. 96E+00 1. 87E+00 6.15E+00 TM 09 59889 05/09/01 Th-232 4. 94E+00 4. 68E+00 3. 98E+01 TM 09 59889 05/09/01 Ag-lIOM 1. 03E+00 1. 74E+00 6.06E+00 TM 09 59889 05/09/01 Ba-140 1. 15E+00 1. 99E+00 7 . 20E+00 TM 09 59889 05/09/01 Be-7 -1. 49E+01 1. 03E+01 3. 93E+01 TM 09 59889 05/09/01 Ce-141 -1. 69E+00 2. 21E+00 7. 78E+00 TM 09 59889 05/09/01 Ce-144 1. 16E+01 7 74E+00 2. 56E+01 TM 09 59889 05/09/01 Co-57 -0. 37E+00 1. 02E+00 3. 57E+00 TM 09 59889 05/09/01 Co-58 2. 14E+00 1. 24E+00 4. 04E+00 TM 09 59889 05/09/01 Co-60 -2. 17E+00 1. 37E+00 5. 52E+00 TM 09 59889 05/09/01 Cr-51 -1. 20E+01 1. 16E+01 4. 24E+01 TM 09 59889 05/09/01 Cs-134 0. 24E+00 1. 10E+00 3. 98E+00 TM 09 59889 05/09/01 Cs-137 3. 11E+00 1. 23E+00 3. 79E+00 TM 09 59889 05/09/01 Fe-59 -3. 41E+00 4. 08E+00 1.55E+01 TM 09 59889 05/09/01 1-131 -8. 26E-02 4. 85E-02 0. 38E+00 TM 09 59889 05/09/01 K-40 1. 45E+03 5 47E+01 5 .24E+01
- TM 09 59889 05/09/01 Mn-54 1. 71E+00 1. 18E+00 3. 90E+00 TM 09 59889 05/09/01 Ru-103 -0. 95E+00 1. 44E+00 5. 25E+00 TM 09 59889 05/09/01 Ru-106 -4. 54E+00 9.87E+00 3. 66E+01 TM 09 59889 05/09/01 Sb-124 0. OOE+00 2. 12E+00 8 .42E+00 TM 09 59889 05/09/01 Se-75 -2. 19E+00 1. 59E+00 5. 80E+00 TM 09 59889 05/09/01 Zn-65 0. 69E+00 3. 09E+00 1. 10E+01 TM 09 59889 05/09/01 Zr-95 0. 74E+00 2. 16E+00 7. 68E+00
- Concentration Greater than 3 Standard Deviations 82
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 09 60115 05/23/01 Th-232 -8.53E+00 6.26E+00 2.53E+01 TM 09 60115 05/23/01 Ag-lIOM 4.08E+00 2.75E+00 9.10E+00 TM 09 60115 05/23/01 Ba-140 -0.64E+00 2.48E+00 1.02E+01 TM 09 60115 05/23/01 Be-7 -5.16E+00 1.39E+01 5.14E+01 TM 09 60115 05/23/01 Ce-141 -3.33E+00 2.41E+00 8.80E+00 TM 09 60115 05/23/01 Ce-144 1.98E+01 9.80E+00 3.18E+01 TM 09 60115 05/23/01 Co-57 -0.46E+00 1.20E+00 4.21E+00 TM 09 60115 05/23/01 Co-58 -0.71E+00 1.74E+00 6.63E+00 TM 09 60115 05/23/01 Co-60 3.04E+00 1.75E+00 5.58E+00 TM 09 60115 05/23/01 Cr-51 1.49E+01 1.46E+01 4.93E+01 TM 09 60115 05/23/01 Cs-134 -7.11E-02 1.70E+00 6.39E+00 TM 09 60115 05/23/01 Cs-137 1.54E+00 1.92E+00 6.63E+00 TM 09 60115 05/23/01 Fe-59 1.21E+01 5.97E+00 1.87E+01 TM 09 60115 05/23/01 1-131 0.76E+00 0.31E+00 0.85E+00 TM 09 60115 05/23/01 K-40 1.34E+03 7.44E+01 8.76E+01
- TM 09 60115 05/23/01 Mn-54 -0.26E+00 1.56E+00 5.88E+00 TM 09 60115 05/23/01 Ru-103 -0.22E+00 1.61E+00 5.94E+00 TM 09 60115 05/23/01 Ru-106 -1.23E+01 1.51E+01 5.79E+01 TM 09 60115 05/23/01 Sb-124 -1.01E+00 3.36E+00 1.43E+01 TM 09 60115 05/23/01 Se-75 1.77E+00 2.02E+00 6.85E+00 TM 09 60115 05/23/01 Zn-65 1.93E+00 4.31E+00 1.54E+01 TM 09 60115 05/23/01 Zr-95 -1.68E+00 2.95E+00 1.14E+01 TM 09 60418 06/06/01 Th-232 1.22E+00 7.87E+00 2.83E+01 TM 09 60418 06/06/01 Ag-IIOM -0.38E+00 2.80E+00 1.03E+01 TM 09 60418 06/06/01 Ba-140 0.00E+00 3.50E+00 1.39E+01 TM 09 60418 06/06/01 Be-7 1.85E+00 1.24E+01 4.55E+01 TM 09 60418 06/06/01 Ce-141 -2.23E+00 2.89E+00 1.03E+01 TM 09 60418 06/06/01 Ce-144 4.28E+00 9.61E+00 3.29E+01 TM 09 60418 06/06/01 Co-57 -1.22E+00 1.24E+00 4.42E+00 TM 09 60418 06/06/01 Co-58 1.07E+00 1.47E+00 5.26E+00 TM 09 60418 06/06/01 Co-60 -0.88E+00 1.80E+00 7.22E+00 TM 09 60418 06/06/01 Cr-51 4.46E+01 1.71E+01 5.32E+01 TM 09 60418 06/06/01 Cs-134 0.11E+00 1.61E+00 6.02E+00 TM 09 60418 06/06/01 Cs-137 1.75E+00 1.97E+00 6.77E+00 TM 09 60418 06/06/01 Fe-59 5.62E+00 6.31E+00 2.20E+01 TM 09 60418 06/06/01 1-131 9.43E-02 0.16E+00 0.80E+00 TM 09 60418 06/06/01 K-40 1.33E+03 7.30E+01 7.56E+01
- TM 09 60418 06/06/01 Mn-54 -2.33E+00 1.88E+00 7.41E+00 TM 09 60418 06/06/01 Ru-103 -0.48E+00 1.63E+00 6.13E+00 TM 09 60418 06/06/01 Ru-106 -2.14E+01 1.54E+01 6.07E+01 TM 09 60418 06/06/01 Sb-124 3.25E+00 3.90E+00 1.42E+01 TM 09 60418 06/06/01 Se-75 -1.28E+00 2.04E+00 7.40E+00 TM 09 60418 06/06/01 Zn-65 -9.13E+00 5.05E+00 2.02E+01 TM 09 60418 06/06/01 Zr-95 1.05E+00 3.23E+00 1.17E+01
- Concentration Greater than 3 Standard Deviations
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 09 60615 06/20/01 Th-232 2. 58E+00 7. 09E+00 2. 55E+01 TM 09 60615 06/20/01 Ag-IlOM 3. 17E+00 2.69E+00 9. 10E+00 TM 09 60615 06/20/01 Ba-140 0. OOE+00 3. 39E+00 1.33E+01 TM 09 60615 06/20/01 Be-7 7.58E+00 1. 42E+01 5. O1E+01 TM 09 60615 06/20/01 Ce-141 -1. 04E+00 3. 13E+00 1. 10E+01 TM 09 60615 06/20/01 Ce-144 9. 47E+00 1.09E+01 3. 69E+01 TM 09 60615 06/20/01 Co-57 -0. 55E+00 1. 34E+00 4. 69E+00 TM 09 60615 06/20/01 Co-58 -0. 95E+00 1. 99E+00 7. 58E+00 TM 09 60615 06/20/01 Co-60 0. 54E+00 2.22E+00 8.21E+00 TM 09 60615 06/20/01 Cr-51 -3. 90E+01 1.72E+01 6. 73E+01 TM 09 60615 06/20/01 Cs-134 0. 45E+00 1. 77E+00 6. 51E+00 TM 09 60615 06/20/01 Cs-137 -0. 43E+00 1.89E+00 7. 02E+00 TM 09 60615 06/20/01 Fe-59 0. 13E+00 6. 37E+00 2. 38E+01 TM 09 60615 06/20/01 1-131 7. 93E-02 0. 10E+00 0. 4 6E+00 TM 09 60615 06/20/01 K-40 1. 32E+03 7.79E+01 1.08E+02
- TM 09 60615 06/20/01 Mn-54 0 . 54E+00 1. 97E+00 7. 08E+00 TM 09 60615 06/20/01 Ru-103 -2. 19E+00 1. 90E+00 7. 34E+00 TM 09 60615 06/20/01 Ru-106 -1.81E+00 1. 65E+01 6. 05E+01 TM 09 60615 06/20/01 Sb-124 -2. 22E+00 4. 15E+00 1. 76E+01 TM 09 60615 06/20/01 Se-75 -0. 38E+00 2.29E+00 8. 09E+00 TM 09 60615 06/20/01 Zn-65 -6. 17E+00 5. 17E+00 2. 02E+01 TM 09 60615 06/20/01 Zr-95 0.76E+00 3. 48E+00 1. 26E+01 TM 09 60913 07/11/01 Th-232 5. 11E+00 6. 10E+00 2. 13E+01 TM 09 60913 07/11/01 Ag-IIOM 1. 48E+00 2.29E+00 8. 12E+00 TM 09 60913 07/11/01 Ba-140 -0. 63E+00 2.29E+00 9. 53E+00 TM 09 60913 07/11/01 Be-7 -5. 15E+00 1. 47E+01 5. 39E+01 TM 09 60913 07/11/01 Ce-141 -1. 94E+00 2. 50E+00 8. 92E+00 TM 09 60913 07/11/01 Ce-144 -3.57E+00 9.81E+00 3. 44E+01 TM 09 60913 07/11/01 Co-57 -1. 15E+00 1. 21E+00 4. 32E+00 TM 09 60913 07/11/01 Co-58 0. 13E+00 1. 83E+00 6. 72E+00 TM 09 60913 07/11/01 Co-60 -0. 32E+00 1. 47E+00 5. 95E+00 TM 09 60913 07/11/01 Cr-51 -1.33E+01 1. 53E+01 5. 64E+01 TM 09 60913 07/11/01 Cs-134 0. 64E+00 1. 60E+00 5. 85E+00 TM 09 60913 07/11/01 Cs-137 0. 65E+00 2. 01E+00 7. 15E+00 TM 09 60913 07/11/01 Fe-59 -1. 23E+01 6. 19E+00 2. 59E+01 TM 09 60913 07/11/01 1-131 0. 11E+00 8. lOE-02 0. 33E+00 TM 09 60913 07/11/01 K-40 1.23E+03 7.14E+01 8.67E+01
- TM 09 60913 07/11/01 Mn-54 1. 02E+00 1. 98E+00 6. 98E+00 TM 09 60913 07/11/01 Ru-103 -1.08E+00 1. 52E+00 5. 82E+00 TM 09 60913 07/11/01 Ru-106 6. 13E+00 1. 18E+01 4. 26E+01 TM 09 60913 07/11/01 Sb-124 1.01E+00 3. 91E+00 1. 52E+01 TM 09 60913 07/11/01 Se-75 -0. 18E+00 2. 10E+00 7.40E+00 TM 09 60913 07/11/01 Zn-65 -2.57E+00 4. 35E+00 1. 67E+01 TM 09 60913 07/11/01 Zr-95 -3. 29E+00 3. 05E+00 1.21E+01
- Concentration Greater than 3 Standard Deviations 84
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 09 61170 07/25/01 Th-232 -1.71E+00 6. 33E+00 2. 39E+01 TM 09 61170 07/25/01 Ag-IIOM -1. 85E+00 2. 25E+00 8 88E+00 TM 09 61170 07/25/01 Ba-140 -1.20E+00 2. 25E+00 9. 53E+00 TM 09 61170 07/25/01 Be-7 1. 19E+01 1. 19E+01 4. 07E+01 TM 09 61170 07/25/01 Ce-141 -0. 43E+00 2.52E+00 8 .82E+00 TM 09 61170 07/25/01 Ce-144 1. 17E+01 9. 80E+00 3. 27E+01 TM 09 61170 07/25/01 Co-57 -0. 32E+00 1.24E+00 4. 33E+00 TM 09 61170 07/25/01 Co-58 1. 40E+00 1. 57E+00 5. 48E+00 TM 09 61170 07/25/01 Co-60 -0. 87E+00 1. 80E+00 7 .20E+00 TM 09 61170 07/25/01 Cr-51 1. 73E+01 1. 40E+01 4. 69E+01 TM 09 61170 07/25/01 Cs-134 -3. 55E-02 2. 02E+00 7. 43E+00 TM 09 61170 07/25/01 Cs-137 1. 22E+00 1. 97E+00 6.90E+00 TM 09 61170 07/25/01 Fe-59 -3. 29E+00 6. 25E+00 2. 39E+01 TM 09 61170 07/25/01 1-131 0. 29E+00 0. 17E+00 0. 57E+00 TM 09 61170 07/25/01 K-40 1. 43E+03 7. 48E+01 6.73E+01
- TM 09 61170 07/25/01 Mn-54 -1. 02E+00 1. 80E+00 6. 85E+00 TM 09 61170 07/25/01 Ru-103 -1. 28E+00 1. 68E+00 6. 35E+00 TM 09 61170 07/25/01 Ru-106 -2. 18E+01 1. 37E+01 5. 56E+01 TM 09 61170 07/25/01 Sb-124 0 00E+00 4. 24E+00 1. 66E+01 TM 09 61170 07/25/01 Se-75 1. 05E+00 2. 11E+00 7 .26E+00 TM 09 61170 07/25/01 Zn-65 1. 28E+00 4 .95E+00 1. 75E+01 TM 09 61170 07/25/01 Zr-95 -1. 54E+00 3. 03E+00 1. 16E+01 TM 09 61369 08/08/01 Th-232 4 .17E+00 4.24E+00 1. 45E+01 TM 09 61369 08/08/01 Ag-11OM 0.79E+00 1. 85E+00 6. 48E+00 TM 09 61369 08/08/01 Ba-140 -0. 59E+00 1. 62E+00 6. 31E+00 TM 09 61369 08/08/01 Be-7 -1. 37E+01 9. 72E+00 3. 68E+01 TM 09 61369 08/08/01 Ce-141 -2. 24E+00 2 . 08E+00 7. 37E+00 TM 09 61369 08/08/01 Ce-144 -9. 36E+00 7. 60E+00 2. 72E+01 TM 09 61369 08/08/01 Co-57 -0. 56E+00 1. 04E+00 3. 63E+00 TM 09 61369 08/08/01 Co-58 -0. 14E+00 1. 21E+00 4.40E+00 TM 09 61369 08/08/01 Co-60 1. 30E+00 1. 19E+00 4. 07E+00 TM 09 61369 08/08/01 Cr-51 -1. 14E+01 1. 03E+01 3. 79E+01 TM 09 61369 08/08/01 Cs-134 -0. 15E+00 1. 26E+00 4 .58E+00 TM 09 61369 08/08/01 Cs-137 2. 86E+00 1. 41E+00 4. 54E+00 TM 09 61369 08/08/01 Fe-59 -1. 14E+00 3. 66E+00 1. 36E+01 TM 09 61369 08/08/01 1-131 0.28E+00 0. 21E+00 0. 77E+00 TM 09 61369 08/08/01 K-40 1.45E+03 5. 34E+01 4.88E+01
- TM 09 61369 08/08/01 Mn-54 -1.23E+00 1. 14E+00 4. 35E+00 TM 09 61369 08/08/01 Ru-103 0. 74E+00 1. 20E+00 4. 16E+00 TM 09 61369 08/08/01 Ru-106 9. 12E+00 9. 45E+00 3. 23E+01 TM 09 61369 08/08/01 Sb-124 -4. 10E+00 2. 39E+00 1. 05E+01 TM 09 61369 08/08/01 Se-75 1. 43E+00 1. 57E+00 5. 31E+00 TM 09 61369 08/08/01 Zn-65 -3. 18E+00 3. 27E+00 1.22E+01 TM 09 61369 08/08/01 Zr-95 -1. 49E+00 1. 92E+00 7. 29E+00
- Concentration Greater than 3 Standard Deviations 85
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 09 61549 08/22/01 Th-232 -1. OOE+00 4. 36E+00 1. 59E+01 TM 09 61549 08/22/01 Ag-IIOM 0. 40E+00 1. 57E+00 5. 63E+00 TM 09 61549 08/22/01 Ba-140 1. 17E+00 2. 30E+00 8. 28E+00 TM 09 61549 08/22/01 Be-7 3. 14E+00 9. 77E+00 3. 44E+01 TM 09 61549 08/22/01 Ce-141 0. 31E+00 2 18E+00 7 51E+00 TM 09 61549 08/22/01 Ce-144 1. 16E+00 7. 76E+00 2. 67E+01 TM 09 61549 08/22/01 Co-57 -0. 33E+00 1. 03E+00 3. 57E+00 TM 09 61549 08/22/01 Co-58 0. 90E+00 1. 15E+00 3. 99E+00 TM 09 61549 08/22/01 Co-60 0. 37E+00 1. 12E+00 4. 08E+00 TM 09 61549 08/22/01 Cr-51 1.20E+01 1. 29E+01 4. 35E+01 TM 09 61549 08/22/01 Cs-134 1. 08E+00 1. 26E+00 4. 35E+00 TM 09 61549 08/22/01 Cs-137 1. 91E+00 1. 26E+00 4. 17E+00 TM 09 61549 08/22/01 Fe-59 -7. 20E+00 3. 79E+00 1. 54E+01 TM 09 61549 08/22/01 1-131 0. 15E+00 0. 17E+00 0. 78E+00 TM 09 61549 08/22/01 K-40 1. 36E+03 5. 23E+01 5. 58E+01
- TM 09 61549 08/22/01 Mn-54 0. 14E+00 1. 17E+00 4. 19E+00 TM 09 61549 08/22/01 Ru-103 -0. 94E+00 1.29E+00 4. 77E+00 TM 09 61549 08/22/01 Ru-106 -1. 65E+01 1.04E+01 4. 02E+01 TM 09 61549 08/22/01 Sb-124 0 . 88E+00 2.91E+00 1.07E+01 TM 09 61549 08/22/01 Se-75 -0. 57E+00 1. 68E+00 5. 90E+00 TM 09 61549 08/22/01 Zn-65 -3. 48E+00 3. 22E+00 1.21E+01 TM 09 61549 08/22/01 Zr-95 -0. 56E+00 2. 06E+00 7. 61E+00 TM 09 61798 09/05/01 Th-232 0. 66E+00 5.47E+00 1. 93E+01 TM 09 61798 09/05/01 Ag-iIOM -0. 61E+00 1. 83E+00 6. 69E+00 TM 09 61798 09/05/01 Ba-140 0. 61E+00 1. 68E+00 6. 18E+00 TM 09 61798 09/05/01 Be-7 -3. 03E+00 1. 08E+01 3. 88E+01 TM 09 61798 09/05/01 Ce-141 -0. 51E+00 2. 58E+00 8 .85E+00 TM 09 61798 09/05/01 Ce-144 4 . OOE+00 9. 90E+00 3. 35E+01 TM 09 61798 09/05/01 Co-57 1. 11E+00 1.25E+00 4.19E+00 TM 09 61798 09/05/01 Co-58 -1. 63E+00 1. 33E+00 5. 08E+00 TM 09 61798 09/05/01 Co-60 0. 31E+00 1. 56E+00 5. 60E+00 TM 09 61798 09/05/01 Cr-51 9. 03E+00 1.32E+01 4.49E+01 TM 09 61798 09/05/01 Cs-134 -1. 33E+00 1. 41E+00 5. 29E+00 TM 09 61798 09/05/01 Cs-137 -1. 21E+00 1. 81E+00 6. 47E+00 TM 09 61798 09/05/01 Fe-59 3. 88E+00 4. 05E+00 1. 39E+01 TM 09 61798 09/05/01 1-131 0. 26E+00 0. 18E+00 0. 65E+00 TM 09 61798 09/05/01 K-40 1. 39E+03 5. 45E+01 6.32E+01
- TM 09 61798 09/05/01 Mn-54 1. 42E+00 1. 51E+00 5. 13E+00 TM 09 61798 09/05/01 Ru-103 3. 03E+00 1. 52E+00 4.89E+00 TM 09 61798 09/05/01 Ru-106 -2. 92E+01 1. 23E+01 4.80E+01 TM 09 61798 09/05/01 Sb-124 0. 51E+00 3. OOE+00 1. 11E+01 TM 09 61798 09/05/01 Se-75 2. 59E+00 1. 94E+00 6. 43E+00 TM 09 61798 09/05/01 Zn-65 -1. 69E+00 7 .80E+00 2. 67E+01 TM 09 61798 09/05/01 Zr-95 -0. 19E+00 2 12E+00 7.70E+00
- Concentration Greater than 3 Standard Deviations 86
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 09 61983 09/19/01 Th-232 -1. 71E+00 6. 48E+00 2 44E+01 TM 09 61983 09/19/01 Ag-110M -1. 11E+00 2. 25E+00 8. 70E+00 TM 09 61983 09/19/01 Ba-140 1. 21E+00 1 91E+00 7.26E+00 TM 09 61983 09/19/01 Be-7 -5. 09E+00 1 28E+01 4. 78E+01 TM 09 61983 09/19/01 Ce-141 -1. 30E+00 2. 50E+00 8 83E+00 TM 09 61983 09/19/01 Ce-144 -1. 80E+01 9. 64E+00 3. 54E+01 TM 09 61983 09/19/01 Co-57 0. 15E+00 1. 25E+00 4. 31E+00 TM 09 61983 09/19/01 Co-58 -1. 40E+00 1. 48E+00 5. 99E+00 TM 09 61983 09/19/01 Co-60 0. 60E+00 1 94E+00 7 .20E+00 TM 09 61983 09/19/01 Cr-51 1. 45E+01 1 57E+01 5. 33E+01 TM 09 61983 09/19/01 Cs-134 -2. 06E+00 1 84E+00 7 . 32E+00 TM 09 61983 09/19/01 Cs-137 3. 33E+00 1 71E+00 5 42E+00 TM 09 61983 09/19/01 Fe-59 1. 18E+00 5. 54E+00 2. 04E+01 TM 09 61983 09/19/01 1-131 -2. 73E-03 7. 72E-02 0. 56E+00 TM 09 61983 09/19/01 K-40 1. 28E+03 7. 19E+01 7 .86E+01
- TM 09 61983 09/19/01 Mn-54 -3. 06E+00 1. 77E+00 7 19E+00 TM 09 61983 09/19/01 Ru-103 -0. 21E+00 1. 58E+00 5. 83E+00 TM 09 61983 09/19/01 Ru-106 -6. 46E+00 1. 58E+01 5. 89E+01 TM 09 61983 09/19/01 Sb-124 1.00E+00 3. 32E+00 1. 31E+01 TM 09 61983 09/19/01 Se-75 -1. 23E+00 1. 88E+00 6. 86E+00 TM 09 61983 09/19/01 Zn-65 -3. 20E+00 4. 66E+00 1.78E+01 TM 09 61983 09/19/01 Zr-95 -0. 63E+00 2. 63E+00 1. 01E+01 TM 09 62463 10/17/01 Th-232 -0. 42E+00 4 40E+00 1. 59E+01 TM 09 62463 10/17/01 Ag-11CM 2. 64E+00 1. 69E+00 5. 56E+00 TM 09 62463 10/17/01 Ba-140 0. 30E+00 1. 63E+00 6. 09E+00 TM 09 62463 10/17/01 Be-7 -9. 44E+00 9. 82E+00 3. 63E+01 TM 09 62463 10/17/01 Ce-141 -0. 62E+00 1. 93E+00 6.73E+00 TM 09 62463 10/17/01 Ce-144 -0. 95E+00 7. 20E+00 2 50E+01 TM 09 62463 10/17/01 Co-57 0. 35E+00 0. 90E+00 3. 06E+00 TM 09 62463 10/17/01 Co-58 -3. 4 6E-02 0. 97E+00 3. 57E+00 TM 09 62463 10/17/01 Co-60 0. 94E+00 1. 36E+00 4. 74E+00 TM 09 62463 10/17/01 Cr-51 5. 99E+00 1. 11E+01 3. 82E+01 TM 09 62463 10/17/01 Cs-134 -0. 53E+00 1. 20E+00 4 45E+00 TM 09 62463 10/17/01 Cs-137 1.26E+00 1. 31E+00 4 43E+00 TM 09 62463 10/17/01 Fe-59 3. 83E+00 3. 62E+00 1.23E+01 TM 09 62463 10/17/01 1-131 0. 11E+00 0. 13E+00 0. 63E+00 TM 09 62463 10/17/01 K-40 1. 30E+03 5. 07E+01 5. 87E+01 TM 09 62463 10/17/01 Mn-54 -0. 21E+00 0. 98E+00 3. 62E+00 TM 09 62463 10/17/01 Ru-103 0. 83E+00 1. 17E+00 4. 02E+00 TM 09 62463 10/17/01 Ru-106 2.72E+00 1. 01E+01 3. 56E+01 TM 09 62463 10/17/01 Sb-124 -0. 48E+00 2. 28E+00 8. 96E+00 TM 09 62463 10/17/01 Se-75 -5. 23E-02 1. 16E+00 4. 11E+00 TM 09 62463 10/17/01 Zn-65 -6. 99E+00 3. 05E+00 1.20E+01 TM 09 62463 10/17/01 Zr-95 -0. 56E+00 1. 91E+00 7. 04E+00
- Concentration Greater than 3 Standard Deviations 87
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 09 62936 11/14/01 Th-232 0. 24E+00 7. 04E+00 2.58E+01 TM 09 62936 11/14/01 Ag-11CM 2. 60E+00 2.32E+00 7. 90E+00 TM 09 62936 11/14/01 Ba-140 -5. 73E+00 2.47E+00 1.20E+01 TM 09 62936 11/14/01 Be-7 1. 03E+01 1. 14E+01 3. 95E+01 TM 09 62936 11/14/01 Ce-141 -7. 24E+00 2.43E+00 9. 29E+00 TM 09 62936 11/14/01 Ce-144 1. 19E+00 9. 23E+00 3.20E+01 TM 09 62936 11/14/01 Co-57 -0. 65E+00 1. 18E+00 4.18E+00 TM 09 62936 11/14/01 Co-58 -0. 84E+00 1. 58E+00 6. 16E+00 TM 09 62936 11/14/01 Co-60 -0. 55E+00 1. 92E+00 7.48E+00 TM 09 62936 11/14/01 Cr-51 2. 52E+01 1. 41E+01 4. 59E+01 TM 09 62936 11/14/01 Cs-134 2. 95E+00 1. 83E+00 5. 99E+00 TM 09 62936 11/14/01 Cs-137 0. 69E+00 1. 74E+00 6. 21E+00 TM 09 62936 11/14/01 Fe-59 6. 44E+00 5. 29E+00 1.79E+01 TM 09 62936 11/14/01 1-131 7 . 01E-02 0. 14E+00 0. 83E+00 TM 09 62936 11/14/01 K-40 1. 50E+03 7. 77E+01 8.07E+01 TM 09 62936 11/14/01 Mn-54 2. 30E+00 1. 93E+00 6. 52E+00 TM 09 62936 11/14/01 Ru-103 -1. 08E+00 1. 64E+00 6. 21E+00 TM 09 62936 11/14/01 Ru-106 -2. 79E+01 1. 55E+01 6. 21E+01 TM 09 62936 11/14/01 Sb-124 6. 07E+00 4. 04E+00 1. 33E+01 TM 09 62936 11/14/01 Se-75 -1.41E+00 2. 03E+00 7. 35E+00 TM 09 62936 11/14/01 Zn-65 -5. 13E+00 4. 35E+00 1.72E+01 TM 09 62936 11/14/01 Zr-95 1. 56E+00 2. 71E+00 9. 72E+00 TM 09 63302 12/12/01 Th-232 1. 66E+01 6.82E+00 2. 08E+01 TM 09 63302 12/12/01 Ag-IIOM 0. 37E+00 2. 19E+00 8. 09E+00 TM 09 63302 12/12/01 Ba-140 1. 80E+00 2. 47E+00 9. 01E+00 TM 09 63302 12/12/01 Be-7 -1.02E+01 1.27E+01 4. 85E+01 TM 09 63302 12/12/01 Ce-141 2. 82E+00 2.4 6E+00 8. 21E+00 TM 09 63302 12/12/01 Ce-144 5. 94E+00 1. 02E+01 3. 48E+01 TM 09 63302 12/12/01 Co-57 0. 98E+00 1. 19E+00 4 . 01E+00 TM 09 63302 12/12/01 Co-58 -2. 30E+00 1.59E+00 6.55E+00 TM 09 63302 12/12/01 Co-60 2. 76E+00 1. 52E+00 4. 74E+00 TM 09 63302 12/12/01 Cr-51 4.32E+00 1.45E+01 5. 08E+01 TM 09 63302 12/12/01 Cs-134 -2. 06E+00 1.84E+00 7. 32E+00 TM 09 63302 12/12/01 Cs-137 0. 20E+00 1. 95E+00 7. 02E+00 TM 09 63302 12/12/01 Fe-59 -7.39E+00 6.44E+00 2. 54E+01 TM 09 63302 12/12/01 1-131 2. 81E-02 0. 11E+00 0.76E+00 TM 09 63302 12/12/01 K-40 1. 30E+03 7. 26E+01 8.07E+01
- TM 09 63302 12/12/01 Mn-54 0. 25E+00 1.78E+00 6. 50E+00 TM 09 63302 12/12/01 Ru-103 -1. 28E+00 1.56E+00 6. 00E+00 TM 09 63302 12/12/01 Ru-106 1. 19E+01 1.50E+01 5. 20E+01 TM 09 63302 12/12/01 Sb-124 0. 00E+00 3. 99E+00 1.58E+01 TM 09 63302 12/12/01 Se-75 -0.35E+00 2. 09E+00 7.4 OE+00 TM 09 63302 12/12/01 Zn-65 5.76E+00 4.74E+00 1. 60E+01 TM 09 63302 12/12/01 Zr-95 7. 01E+00 2. 64E+00 7.61E+00 TM 15 58093 01/10/01 Th-232 1 . 07E+00 4. 11E+00 1.47E+01
- Concentration Greater than 3 Standard Deviations 88
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 15 58093 01/10/01 Ag-lIIM -0. 60E+00 1. 70E+00 6.25E+00 TM 15 58093 01/10/01 Ba-140 0. 36E+00 1. 82E+00 6.87E+00 TM 15 58093 01/ 10/0 1 Be-7 7 .22E+00 9. 95E+00 3. 43E+01 TM 15 58093 01/ 10/0 1 Ce-141 -1. 10E+00 2 41E+00 8. 36E+00 TM 15 58093 01/10/01 Ce-144 -8 .22E+00 8 . 74E+00 3. 07E+01 TM 15 58093 01/10/01 Co-57 0. 86E+00 1. 09E+00 3. 66E+00 TM 15 58093 01/10/01 Co-58 -3. 13E+00 1. 31E+00 5. 26E+00 TM 15 58093 01/10/01 Co-60 -0. 89E+00 1. 06E+00 4. 25E+00 TM 15 58093 01/10/01 Cr-51 1. 94E+00 1. 21E+01 4. 22E+01 TM 15 58093 01/10/01 Cs-134 0. 00E+00 1. 33E+00 4. 78E+00 TM 15 58093 01/ 10/0 1 Cs-137 0. 45E+00 1. 38E+00 4. 83E+00 TM 15 58093 01/10/01 Fe-59 0. 35E+00 3. 4 6E+00 1. 27E+01 TM 15 58093 01/10/01 1-131 5. 60E-02 0. 10E+00 0. 52E+00 TM 15 58093 01/10/01 K-40 1. 53E+03 5. 59E+01 6. 20E+01 k TM 15 58093 01/10/01 Mn-54 -0. 55E+00 1. 24E+00 4. 54E+00 TM 15 58093 01/10/01 Ru-103 -1. 18E+00 1. 43E+00 5. 24E+00 TM 15 58093 01 /10/01 Ru-106 1. 78E+01 9.51E+00 3. 06E+01 TM 15 58093 01 /10/01 Sb-124 3. 77E+00 2. 35E+00 7. 63E+00 TM 15 58093 01 /10/01 Se-75 -1. 57E+00 1. 63E+00 5. 84E+00 TM 15 58093 01 /10/01 Zn-65 -6. 44E+00 6.54E+00 2.29E+01 TM 15 58093 01 /10/01 Zr-95 -0. 78E+00 2. 25E+00 8.26E+00 TM 15 58595 02/14/01 Th-232 1. 07E+00 5. 15E+00 1.82E+01 TM 15 58595 02/14/01 Ag-11GM -0. 59E+00 1.71E+00 6.26E+00 TM 15 58595 02/14/01 Ba-140 -1. 18E+00 1.39E+00 5. 76E+00 TM 15 58595 02/14/01 Be-7 2. 94E+00 1.05E+01 3. 68E+01 TM 15 58595 02/14/01 Ce-141 1. 41E+00 2. 26E+00 7. 62E+00 TM 15 58595 02/14/01 Ce-144 0. 91E+00 8. 87E+00 3. 04E+01 TM 15 58595 02/14/01 Co-57 -1. 58E+00 1.09E+00 3. 89E+00 TM 15 58595 02/14/01 Co-58 0. 00E+00 1. 24E+00 4 45E+00 TM 15 58595 02/14/01 Co-60 1. 02E+00 1.29E+00 4 49E+00 TM 15 58595 02/14/01 Cr-51 -2. 64E+01 1. 16E+01 4 38E+01 TM 15 58595 02/14/01 Cs-134 -1. 23E+00 1.41E+00 5 26E+00 TM 15 58595 02/14/01 Cs-137 -2. 25E-02 1.41E+00 4. 99E+00 TM 15 58595 02/14/01 Fe-59 -3. 33E+00 3. 73E+00 1. 42E+01 TM 15 58595 02/14/01 1-131 7 .40E-02 0. 12E+00 0. 65E+00 TM 15 58595 02/14/01 K-40 1 46E+03 5. 41E+01 5 56E+01 TM 15 58595 02/14/01 Mn-54 0. 96E+00 1. 10E+00 3. 80E+00 TM 15 58595 02/14/01 Ru-103 -2. 70E+00 1. 61E+00 6.26E+00 TM 15 58595 02/14/01 Ru-106 6. 84E+00 1. 12E+01 3. 89E+01 TM 15 58595 02/14/01 Sb-124 -0. 20E+00 2 .7 6E+00 1. 05E+01 TM 15 58595 02/14/01 Se-75 -0. 55E+00 1. 71E+00 5. 99E+00 TM 15 58595 02/14/01 Zn-65 -7 .72E+00 6.32E+00 2. 24E+01 TM 15 58595 02/14/01 Zr-95 1. 74E+00 2. 12E+00 7 . 29E+00
- Concentration Greater than 3 Standard Deviations 89
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 15 58997 03/14/01 Th-232 -1. 24E+01 4. 99E+00 1. 98E+01 TM 15 58997 03/14/01 Ag-IIOM -1. 38E+00 1. 73E+00 6. 48E+00 TM 15 58997 03/14/01 Ba-140 0. OOE+00 1. 67E+00 6. 30E+00 TM 15 58997 03/14/01 Be-7 9. 81E+00 9. 20E+00 3. 12E+01 TM 15 58997 03/14/01 Ce-141 -5. 02E+00 2. 14E+00 7 . 82E+00 TM 15 58997 03/14/01 Ce-144 1. 07E+01 8. 18E+00 2.72E+01 TM 15 58997 03/14/01 Co-57 -0. 40E+00 1. 04E+00 3. 61E+00 TM 15 58997 03/14/01 Co-58 -0. 14E+00 1. 38E+00 4. 97E+00 TM 15 58997 03/14/01 Co-60 -1.21E+00 1.36E+00 5. 22E+00 TM 15 58997 03/14/01 Cr-51 -7. 04E+00 1. 15E+01 4. 10E+01 TM 15 58997 03/14/01 Cs-134 -0. 61E+00 1. 34E+00 4. 93E+00 TM 15 58997 03/14/01 Cs-137 0. 22E+00 1. 33E+00 4. 72E+00 TM 15 58997 03/14/01 Fe-59 0. 95E+00 3. 99E+00 1. 42E+01 TM 15 58997 03/14/01 1-131 1. 81E-02 7. 24E-02 0. 44E+00 TM 15 58997 03/14/01 K-40 1. 47E+03 5.47E+01 5.90E+01
- TM 15 58997 03/14/01 Mn-54 0. 55E+00 1.21E+00 4. 25E+00 TM 15 58997 03/14/01 Ru-103 -2. 21E+00 1. 16E+00 4. 52E+00 TM 15 58997 03/14/01 Ru-106 -0. 38E+00 1. 12E+01 3. 98E+01 TM 15 58997 03/14/01 Sb-124 -1.80E+00 2. 91E+00 1. 14E+01 TM 15 58997 03/14/01 Se-75 -0. 88E+00 1.55E+00 5. 49E+00 TM 15 58997 03/14/01 Zn-65 -3. 35E+00 3.71E+00 1. 36E+01 TM 15 58997 03/14/01 Zr-95 0. 47E+00 2. 01E+00 7. 20E+00 TM 15 59443 04/11/01 Th-232 -5. 27E+00 6. 91E+00 2. 65E+01 TM 15 59443 04/11/01 Ag-IIOM -1.4 6E+00 2. 37E+00 9. 14E+00 TM 15 59443 04/11/01 Ba-140 4 .15E+00 2. 58E+00 8. 36E+00 TM 15 59443 04/11/01 Be-7 -6. 68E+00 1.25E+01 4.71E+01 TM 15 59443 04/11/01 Ce-141 2. 13E+00 2. 60E+00 8. 79E+00 TM 15 59443 04/11/01 Ce-144 1. 02E+01 9. 36E+00 3. 14E+01 TM 15 59443 04/11/01 Co-57 0. 49E+00 1.24E+00 4. 23E+00 TM 15 59443 04/11/01 Co-58 -1. 97E+00 1. 63E+00 6. 57E+00 TM 15 59443 04/11/01 Co-60 3.32E+00 1. 85E+00 5.88E+00 TM 15 59443 04/11/01 Cr-51 -4.26E+00 1.59E+01 5. 66E+01 TM 15 59443 04/11/01 Cs-134 -0. 91E+00 1. 61E+00 6.30E+00 TM 15 59443 04/11/01 Cs-137 2. 24E+00 1. 70E+00 5. 68E+00 TM 15 59443 04/11/01 Fe-59 4.52E+00 4. 76E+00 1. 67E+01 TM 15 59443 04/11/01 1-131 6. 67E-02 0. 11E+00 0. 56E+00 TM 15 59443 04/11/01 K-40 1.50E+03 7. 77E+01 8.57E+01
- TM 15 59443 04/11/01 Mn-54 -0.25E+00 1. 69E+00 6. 30E+00 TM 15 59443 04/11/01 Ru-103 -3. 15E+00 1. 61E+00 6. 51E+00 TM 15 59443 04/11/01 Ru-106 1. 17E+01 1. 48E+01 5. 14E+01 TM 15 59443 04/11/01 Sb-124 2. 96E+00 2. 61E+00 9. 16E+00 TM 15 59443 04/11/01 Se-75 -0. 52E+00 2.19E+00 7.74E+00 TM 15 59443 04/11/01 Zn-65 -5. 69E+00 5.25E+00 2. 01E+01 TM 15 59443 04/11/01 Zr-95 2. 08E+00 2.81E+00 9. 91E+00
- Concentration Greater than 3 Standard Deviations 90
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 15 59605 04/25/01 Th-232 7. 97E+00 6. 12E+00 2. 05E+01 TM 15 59605 04/25/01 Ag-IIOM 4 .15E+00 1. 75E+00 5. 31E+00 TM 15 59605 04/25/01 Ba-140 0. 38E+00 1. 93E+00 7. 65E+00 TM 15 59605 04/25/01 Be-7 1. 23E+01 1. 23E+01 4. 18E+01 TM 15 59605 04/25/01 Ce-141 0. 74E+00 2 42E+00 8.29E+00 TM 15 59605 04/25/01 Ce-144 -2.47E+00 8. 62E+00 3. 01E+01 TM 15 59605 04/25/01 Co-57 2. 34E+00 1. 16E+00 3. 76E+00 TM 15 59605 04/25/01 Co-58 -2.4 6E+00 1. 35E+00 5. 58E+00 TM 15 59605 04/25/01 Co-60 -0.81E+00 1. 61E+00 6.25E+00 TM 15 59605 04/25/01 Cr-51 -9. 91E+00 1. 41E+01 5. 12E+01 TM 15 59605 04/25/01 Cs-134 -3. 36E+00 1. 43E+00 6. 04E+00 TM 15 59605 04/25/01 Cs-137 1. 16E+00 1. 61E+00 5. 59E+00 TM 15 59605 04/25/01 Fe-59 -4. 50E+00 5. 38E+00 2. 07E+01 TM 15 59605 04/25/01 1-131 -8. 63E-02 7. 08E-02 0. 55E+00 TM 15 59605 04/25/01 K-40 1. 38E+03 6. 43E+01 7. 20E+01
- TM 15 59605 04/25/01 Mn-54 -1. 40E+00 1. 43E+00 5. 52E+00 TM 15 59605 04/25/01 Ru-103 1.22E+00 1. 57E+00 5 40E+00 TM 15 59605 04/25/01 Ru-106 2. 59E+00 1. 28E+01 4. 57E+01 TM 15 59605 04/25/01 Sb-124 4. 57E+00 2. 64E+00 8. 20E+00 TM 15 59605 04/25/01 Se-75 1. 98E+00 1. 78E+00 5. 96E+00 TM 15 59605 04/25/01 Zn-65 -2. 39E+00 3. 28E+00 1. 27E+01 TM 15 59605 04/25/01 Zr-95 -0. 31E+00 2. 27E+00 8. 50E+00 TM 15 59890 05/09/01 Th-232 -3. 38E+00 4. 51E+00 1. 68E+01 TM 15 59890 05/09/01 Ag-IlOM 1. 52E+00 1. 72E+00 5. 90E+00 TM 15 59890 05/09/01 Ba-140 0. 35E+00 2. 04E+00 7. 55E+00 TM 15 59890 05/09/01 Be-7 5. 88E+00 1. 03E+01 3. 56E+01 TM 15 59890 05/09/01 Ce-141 5. 19E+00 2. 33E+00 7. 52E+00 TM 15 59890 05/09/01 Ce-144 -1. 35E+01 7. 99E+00 2. 87E+01 TM 15 59890 05 /09/01 Co-57 9. 41E-03 1. 03E+00 3. 54E+00 TM 15 59890 05 /09/01 Co-58 1. 44E+00 1. 14E+00 3. 84E+00 TM 15 59890 05 /09/01 Co-60 0. 96E+00 1. 33E+00 4. 64E+00 TM 15 59890 05 /09/01 Cr-51 -2. 39E+01 1. 27E+01 4. 70E+01 TM 15 59890 05/09/01 Cs-134 0. 11E+00 1. 04E+00 3. 79E+00 TM 15 59890 05/09/01 Cs-137 -1. 95E+00 1. 43E+00 S. 33E+00 TM 15 59890 05/09/01 Fe-59 0. 97E+00 3. 75E+00 1. 34E+01 TM 15 59890 05/09/01 1-131 6. OOE-02 0. 15E+00 0. 85E+00 TM 15 59890 05/09/01 K-40 1. 51E+03 5. 34E+01 4 .90E+01
- TM 15 59890 05/09/01 Mn-54 -1.78E+00 1. 01E+00 4. 04E+00 TM 15 59890 05/09/01 Ru-103 -0. 12E+00 1. 30E+00 4 .65E+00 TM 15 59890 05/09/01 Ru-106 -3. 28E+00 1. 11E+01 4 00E+01 TM 15 59890 05/09/01 Sb-124 0.4 9E+00 2. 03E+00 7. 81E+00 TM 15 59890 05/09/01 Se-75 1. 17E+00 1. 64E+00 5. 55E+00 TM 15 59890 05/09/01 Zn-65 -2. 24E+00 4. 03E+00 1.47E+01 TM 15 59890 05/09/01 Zr-95 -0. 87E+00 2. 21E+00 8. 10E+00
- Concentration Greater than 3 Standard Deviations 91
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 15 60116 05/23/01 Th-232 -1. 42E+00 6. 20E+00 2. 34E+01 TM 15 60116 05/23/01 Ag-11CM 2. 20E+00 2.4 8E+00 8. 61E+00 TM 15 60116 05/23/01 Ba-140 3. 77E+00 2. 81E+00 9. 42E+00 TM 15 60116 05/23/01 Be-7 5. 08E+00 1.35E+01 4.78E+01 TM 15 60116 05/23/01 Ce-141 -0. 80E+00 2.4 9E+00 8.76E+00 TM 15 60116 05/23/01 Ce-144 1. 01E+01 9. 35E+00 3. 13E+01 TM 15 60116 05/23/01 Co-57 -1. 25E+00 1.21E+00 4.32E+00 TM 15 60116 05/23/01 Co-58 0. 66E+00 1.58E+00 5. 72E+00 TM 15 60116 05/23 /01 Co-60 2. 86E+00 1. 97E+00 6.53E+00 TM 15 60116 05/23/01 Cr-51 1.46E+00 1.46E+01 5. 19E+01 TM 15 60116 05/23/01 Cs-134 0. 28E+00 1.78E+00 6. 55E+00 TM 15 60116 05/23/01 Cs-137 2 . 68E+00 1.50E+00 4 . 82E+00 TM 15 60116 05/23/01 Fe-59 -6. 25E+00 6. 22E+00 2.45E+01 TM 15 60116 05/23/01 1-131 0. 19E+00 0. 17E+00 0 . 73E+00 TM 15 60116 05/23/01 K-40 1. 43E+03 7. 66E+01 9.29E+01
- TM 15 60116 05/23/01 Mn-54 -0. 76E+00 1. 91E+00 7. 11E+00 TM 15 60116 05/23/01 Ru-103 -2. 99E+00 1. 63E+00 6. 55E+00 TM 15 60116 05/23/01 Ru-106 1.58E+01 1.70E+01 5.82E+01 TM 15 60116 05/23/01 Sb-124 -1. 00E+00 2. 64E+00 1.20E+01 TM 15 60116 05/23/01 Se-75 -0. 52E+00 2. 05E+00 7. 28E+00 TM 15 60116 05/23/01 Zn-65 3. 80E+00 4. 30E+00 1. 49E+01 TM 15 60116 05/23/01 Zr-95 -1. 82E+00 2.71E+00 1. 06E+01 TM 15 60419 06/06/01 Th-232 5. 32E+00 7.49E+00 2. 61E+01 TM 15 60419 06/06/01 Ag-IlOM 0. 74E+00 2. 47E+00 8. 94E+00 TM 15 60419 06/06/01 Ba-140 -1.73E+00 3. 24E+00 1. 37E+01 TM 15 60419 06/06/01 Be-7 1. 83E+01 1. 44E+01 4.84E+01 TM 15 60419 06/06/01 Ce-141 -0. 75E+00 2.7 6E+00 9. 70E+00 TM 15 60419 06/06/01 Ce-144 -8.89E+00 9. 47E+00 3. 39E+01 TM 15 60419 06/06/01 Co-57 0. 66E+00 1. 17E+00 3. 98E+00 TM 15 60419 06/06/01 Co-58 1. 83E+00 1.76E+00 6. 06E+00 TM 15 60419 06/06/01 Co-60 -3. 33E+00 2. 05E+00 8. 63E+00 TM 15 60419 06/06/01 Cr-51 -1. 52E+01 1.8 9E+01 6. 89E+01 TM 15 60419 06/06/01 Cs-134 1. 55E+00 2. 02E+00 7. 06E+00 TM 15 60419 06/06/01 Cs-137 -1. 88E+00 1. 95E+00 7.42E+00 TM 15 60419 06/06/01 Fe-59 -2. 20E+00 6.4 1E+00 2. 45E+01 TM 15 60419 06/06/01 1-131 5. 62E-02 0. 15E+00 0. 77E+00 TM 15 60419 06/06/01 K-40 1. 61E+03 7. 96E+01 8.05E+01
- TM 15 60419 06/06/01 Mn-54 -0. 51E+00 2. 08E+00 7. 63E+00 TM 15 60419 06/06/01 Ru-103 -0. 95E+00 1. 87E+00 6. 98E+00 TM 15 60419 06/06/01 Ru-106 -2. 52E+01 1.4 9E+01 5. 99E+01 TM 15 60419 06/06/01 Sb-124 -4.28E+00 3. 38E+00 1. 61E+01 TM 15 60419 06/06/01 Se-75 2. 34E+00 2. 03E+00 6. 80E+00 TM 15 60419 06/06/01 Zn-65 -0. 64E+00 4. 60E+00 1. 70E+01 TM 15 60419 06/06/01 Zr-95 -2.61E+00 3. 15E+00 1.23E+01
- Concentration Greater than 3 Standard Deviations 92
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 15 60616 06/20/01 Th-232 -3. 21E+00 7. 38E+00 2. 77E+01 TM 15 60616 06/20/01 Ag-IIOM -2. 35E+00 2. 93E+00 1. 12E+01 TM 15 60616 06/20/01 Ba-140 1. 58E+00 3. 54E+00 1. 32E+01 TM 15 60616 06/20/01 Be-7 3. 74E+00 1.73E+01 6. 14E+01 TM 15 60616 06/20/01 Ce-141 -9. 77E-02 3. 32E+00 1. 15E+01 TM 15 60616 06/20/01 Ce-144 -1.41E+01 1. 14E+01 4. 06E+01 TM 15 60616 06/20/01 Co-57 -0. 24E+00 1. 42E+00 4. 92E+00 TM 15 60616 06/20/01 Co-58 -0. 87E+00 2 . 04E+00 7.70E+00 TM 15 60616 06/20/01 Co-60 0. 92E+00 2.23E+00 8. 11E+00 TM 15 60616 06/20/01 Cr-51 -6. 69E+00 1. 92E+01 6. 86E+01 TM 15 60616 06/20/01 Cs-134 -0. 75E+00 1. 96E+00 7.45E+00 TM 15 60616 06/20/01 Cs-137 -1. 23E+00 2. 11E+00 7. 86E+00 TM 15 60616 06/20/01 Fe-59 -1. 57E+00 7.14E+00 2. 67E+01 TM 15 60616 06/20/01 1-131 0. 11E+00 0. 17E+00 0. 85E+00 TM 15 60616 06/20/01 K-40 1. 52E+03 8.13E+01 9. 79E+01
- TM 15 60616 06/20/01 Mn-54 1. 61E+00 2. 08E+00 7. 23E+00 TM 15 60616 06/20/01 Ru-103 -3. 35E+00 2. 06E+00 8. 04E+00 TM 15 60616 06/20/01 Ru-106 5. O1E+00 1. 84E+01 6. 53E+01 TM 15 60616 06/20/01 Sb-124 -4. 39E+00 4. 66E+00 1. 99E+01 TM 15 60616 06/20/01 Se-75 1. 50E+00 2.46E+00 8 .40E+00 TM 15 60616 06/20/01 Zn-65 -2 89E+00 1. 19E+01 4 13E+01 TM 15 60616 06/20/01 Zr-95 3. 49E+00 3. 40E+00 1. 17E+01 TM 15 60914 07 /11/01 Th-232 0. 51E+00 6. 49E+00 2. 38E+01 TM 15 60914 07 /11/01 Ag-IIOM -1. 47E+00 2. 37E+00 9. 16E+00 TM 15 60914 07 /11/01 Ba-140 -0. 63E+00 2. 26E+00 9. 42E+00 TM 15 60914 07 /11/01 Be-7 3. 22E+01 1. 45E+01 4. 55E+01 TM 15 60914 07 /11/01 Ce-141 -1. 81E+00 2. 52E+00 8. 96E+00 TM 15 60914 07 /11/01 Ce-144 4 .12E+00 1. 02E+01 3. 48E+01 TM 15 60914 07 /11/01 Co-57 1. 46E+00 1. 23E+00 4. 11E+00 TM 15 60914 07 /11/01 Co-58 -4. 25E+00 1. 87E+00 7. 80E+00 TM 15 60914 07 /11/01 Co-60 0. 64E+00 2 43E+00 8. 83E+00 TM 15 60914 07 /11/01 Cr-51 5. 83E+00 1. 53E+01 5. 33E+01 TM 15 60914 07 /11/01 Cs-134 1. 97E+00 1. 91E+00 6.55E+00 TM 15 60914 07 /11/01 Cs-137 3. 81E+00 2. 56E+00 8 47E+00 TM 15 60914 07 /11/01 Fe-59 0. 24E+00 5 47E+00 2. 05E+01 TM 15 60914 07 /11/01 1-131 7. 71E-02 0. 10E+00 0. 50E+00 TM 15 60914 07 /11/01 K-40 1. 67E+03 8. 03E+01 6. 90E+01
- TM 15 60914 07 /11/01 Mn-54 2. 02E+00 1. 56E+00 5. 23E+00 TM 15 60914 07 /11/01 Ru-103 -i. 28E+00 2. 38E+00 8. 78E+00 TM 15 60914 07 /11/01 Ru-106 -1.75E+01 1. 38E+01 5. 50E+01 TM 15 60914 07 /11/01 Sb-124 -8. 99E+00 3. 87E+00 1. 88E+01 TM 15 60914 07 /11/01 Se-75 -4. 52E+00 2. 28E+00 8. 51E+00 TM 15 60914 07 /11/01 Zn-65 -9. 51E+00 4. 95E+00 1. 99E+01 TM 15 60914 07 /11/01 Zr-95 -0. 34E+00 2. 95E+00 1. 10E+01
- Concentration Greater than 3 Standard Deviations 93
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 15 61171 07/25/01 Th-232 1. 47E+00 6.70E+00 2. 43E+01 TM 15 61171 07/25/01 Ag-11OM -0.73E+00 2. 37E+00 8. 96E+00 TM 15 61171 07/25/01 Ba-140 -2. 99E+00 1. 98E+00 9. 48E+00 TM 15 61171 07/25/01 Be-7 -8. 37E+00 1. 24E+01 4. 72E+01 TM 15 61171 07/25/01 Ce-141 -1. 16E+00 2. 58E+00 9. 07E+00 TM 15 61171 07/25/01 Ce-144 1. 62E+01 9. 85E+00 3.24E+01 TM 15 61171 07/25/01 Co-57 -1. 87E+00 1. 24E+00 4.47E+00 TM 15 61171 07/25/01 Co-58 -0. 53E+00 1. 61E+00 6. 15E+00 TM 15 61171 07/25/01 Co-60 -0. 68E+00 2. 12E+00 8. 15E+00 TM 15 61171 07/25/01 Cr-51 -8. 54E+00 1. 52E+01 5. 52E+01 TM 15 61171 07/25/01 Cs-134 1. 30E+00 1.75E+00 6. 18E+00 TM 15 61171 07/25/01 Cs-137 -0. 40E+00 2. 00E+00 7 . 30E+00 TM 15 61171 07/25/01 Fe-59 -1. 28E+00 6. 17E+00 2. 31E+01 TM 15 61171 07/25/01 1-131 4.7 9E-02 8.84E-02 0. 48E+00 TM 15 61171 07/25/01 K-40 1. 47E+03 7.71E+01 8 82E+01 TM 15 61171 07/25/01 Mn-54 -1.01E+00 1.75E+00 6. 66E+00 TM 15 61171 07/25/01 Ru-103 -0. 84E+00 1.76E+00 6. 52E+00 TM 15 61171 07/25/01 Ru-106 2. 22E+01 1.51E+01 5. 01E+01 TM 15 61171 07/25/0 1 Sb-124 6. 92E+00 3. 28E+00 9. 18E+00 TM 15 61171 07/25/01 Se-75 3. 63E+00 2. 02E+00 6. 59E +00 TM 15 61171 07/25/01 Zn-65 -9. 48E+00 4. 94E+00 1. 98E+01 TM 15 61171 07/25/01 Zr-95 2. 42E+00 2. 73E+00 9. 50E+00 TM 15 61370 08/08/01 Th-232 0. 57E+00 4.72E+00 1. 68E+01 TM 15 61370 08/08/01 Ag-IIOM -0. 94E+00 1. 47E+00 5. 54E+00 TM 15 61370 08/08/01 Ba-140 -1. 14E+00 1. 28E+00 5. 37E+00 TM 15 61370 08/08/01 Be-7 2.42E+01 9. 58E+00 2.99E+01 TM 15 61370 08/08/01 Ce-141 4. 22E+00 1. 98E+00 6.4 1E+00 TM 15 61370 08/08/01 Ce-144 0. 87E+00 7. 60E+00 2. 61E+01 TM 15 61370 08/08/01 Co-57 0. 11E+00 0. 99E+00 3.40E+00 TM 15 61370 08/08/01 Co-58 -1. 32E+00 1. 07E+00 4. 16E+00 TM 15 61370 08/08/01 Co-60 0. 49E+00 1. 44E+00 5. 10E+00 TM 15 61370 08/08/01 Cr-51 -6. 66E+00 1. 07E+01 3. 84E+01 TM 15 61370 08/08/01 Cs-134 -0. 57E+00 1. 17E+00 4. 35E+00 TM 15 61370 08/08/01 Cs-137 0. OOE+00 1. 23E+00 4.38E+00 TM 15 61370 08/08/01 Fe-59 -0. 86E+00 3. 88E+00 1.42E+01 TM 15 61370 08/08/01 1-131 0. 13E+00 0. 15E+00 0. 69E+00 TM 15 61370 08/08/01 K-40 1. 68E+03 5. 71E+01 5.93E+01
- TM 15 61370 08/08/01 Mn-54 -0. 69E+00 0. 99E+00 3. 75E+00 TM 15 61370 08/08/01 Ru-103 -1. 98E+00 1. 13E+00 4. 37E+00 TM 15 61370 08/08/01 Ru-106 -9. 94E+00 1. 08E+01 4. 01E+01 TM 15 61370 08/08/01 Sb-124 0. 94E+00 2. 21E+00 8.19E+00 TM 15 61370 08/08/01 Se-75 -0. 10E+00 1. 54E+00 5. 37E+00 TM 15 61370 08/08/01 Zn-65 -6. 65E+00 3. 09E+00 1.21E+01 TM 15 61370 08/08/01 Zr-95 3. 85E+00 2. 01E+00 6. 46E+00
- Concentration Greater than 3 Standard Deviations 94
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 15 61550 08/22/01 Th-232 2.06E+00 4.26E+00 1.50E+01 TM 15 61550 08/22/01 Ag-IlOM -0.76E+00 1.62E+00 5.99E+00 TM 15 61550 08/22/01 Ba-140 -1.12E+00 1.72E+00 7.05E+00 TM 15 61550 08/22/01 Be-7 1.39E+01 9.94E+00 3.30E+01 TM 15 61550 08/22/01 Ce-141 2.93E+00 2.22E+00 7.37E+00 TM 15 61550 08/22/01 Ce-144 -0.74E+00 7.69E+00 2.66E+01 TM 15 61550 08/22/01 Co-57 0.28E+00 0.95E+00 3.24E+00 TM 15 61550 08/22/01 Co-58 -0.23E+00 1.20E+00 4.37E+00 TM 15 61550 08/22/01 Co-60 -0.98E+00 1.40E+00 5.29E+00 TM 15 61550 08/22/01 Cr-51 9.44E+00 1.16E+01 3.96E+01 TM 15 61550 08/22/01 Cs-134 -1.01E+00 1.14E+00 4.37E+00 TM 15 61550 08/22/01 Cs-137 1.24E+00 1.22E+00 4.15E+00 TM 15 61550 08/22/01 Fe-59 -0.25E+00 4.02E+00 1.46E+01 TM 15 61550 08/22/01 1-131 0.12E+00 0.15E+00 0.74E+00 TM 15 61550 08/22/01 K-40 1.79E+03 5.81E+01 5.09E+01 TM 15 61550 08/22/01 Mn-54 -1.93E+00 1.10E+00 4.34E+00 TM 15 61550 08/22/01 Ru-103 -1.53E+00 1.08E+00 4.18E+00 TM 15 61550 08/22/01 Ru-106 1.50E+01 9.75E+00 3.22E+01 TM 15 61550 08/22/01 Sb-124 -1.49E+00 2.39E+00 9.70E+00 TM 15 61550 08/22/01 Se-75 1.28E+00 1.52E+00 5.14E+00 TM 15 61550 08/22/01 Zn-65 -2.57E+00 2.65E+00 1.01E+01 TM 15 61550 08/22/01 Zr-95 2.29E+00 2.27E+00 7.72E+00 TM 15 61799 09/05/01 Th-232 -4.37E+00 4.29E+00 1.63E+01 TM 15 61799 09/05/01 Ag-IIOM -0.19E+00 1.65E+00 5.98E+00 TM 15 61799 09/05/01 Ba-140 0.OOE+00 1.50E+00 5.70E+00 TM 15 61799 09/05/01 Be-7 4.65E+00 9.53E+00 3.31E+01 TM 15 61799 09/05/01 Ce-141 -1.17E+00 1.99E+00 6.95E+00 TM 15 61799 09/05/01 Ce-144 -3.92E+00 7.58E+00 2.65E+01 TM 15 61799 09/05/01 Co-57 1.27E+00 1.02E+00 3.38E+00 TM 15 61799 09/05/01 Co-58 -0.10E+00 1.23E+00 4.45E+00 TM 15 61799 09/05/01 Co-60 0.78E+00 1.53E+00 5.36E+00 TM 15 61799 09/05/01 Cr-51 4.15E+00 1.08E+01 3.72E+01 TM 15 61799 09/05/01 Cs-134 0.00E+00 1.19E+00 4.30E+00 TM 15 61799 09/05/01 Cs-137 2.12E+00 1.38E+00 4.54E+00 TM 15 61799 09/05/01 Fe-59 3.93E+00 3.90E+00 1.33E+01 TM 15 61799 09/05/01 1-131 4.13E-02 0.11E+00 0.64E+00 TM 15 61799 09/05/01 K-40 1.75E+03 5.73E+01 4.84E+01 TM 15 61799 09/05/01 Mn-54 -0.98E+00 1.05E+00 4.01E+00 TM 15 61799 09/05/01 Ru-103 -3.02E+00 1.21E+00 4.74E+00 TM 15 61799 09/05/01 Ru-106 -5.24E+00 1.08E+01 3.93E+01 TM 15 61799 09/05/01 Sb-124 0.OOE+00 2.48E+00 9.44E+00 TM 15 61799 09/05/01 Se-75 0.73E+00 1.66E+00 5.66E+00 TM 15 61799 09/05/01 Zn-65 7.28E+00 4.32E+00 1.32E+01 TM 15 61799 09/05/01 Zr-95 2.05E+00 2.04E+00 6.95E+00 TM 15 61984 09/19/01 Th-232 -0.76E+00 6.21E+00 2.25E+01
- Concentration Greater than 3 Standard Deviations 95
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
- Concentration Greater than 3 Standard Deviations 96
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 15 61984 09/19/01 Ag-IIOM -1 . 59E+00 1. 96E+00 7. 56E+00 TM 15 61984 09/19/01 Ba-140 1. 82E+00 2. 05E+00 7. 29E+00 TM 15 61984 09/19/01 Be-7 -3. 95E+00 1. 1lE+01 4. 08E+01 TM 15 61984 09/19/01 Ce-141 -3. 76E+00 2. 24E+00 8. 17E+00 TM 15 61984 09/19/01 Ce-144 1.81E+00 8 83E+00 3. 03E+01 TM 15 61984 09/19/01 Co-57 2.29E-02 1. 1lE+00 3. 83E+00 TM 15 61984 09/19/01 Co-58 -1.l IE+00 1. 48E+00 5. 65E+00 TM 15 61984 09/19/01 Co-60 0. 34E+00 1. 60E+00 5. 89E+00 TM 15 61984 09/19/01 Cr-51 2. 77E+01 1. 27E+01 4. 04E+01 TM 15 61984 09/19/01 Cs-134 1. 34E+00 1.56E+00 5. 40E+00 TM 15 61984 09/19/01 Cs-137 3. 37E+00 1.21E+00 3. 55E+00 TM 15 61984 09/19/01 Fe-59 1. 23E+00 4.71E+00 1. 71E+01 TM 15 61984 09/19/01 1-131 8.86E-02 9. 70E-02 0. 45E+00 TM 15 61984 09/19/01 K-40 1.48E+03 6. 55E+01 6.OOE+01
- TM 15 61984 09/19/01 Mn-54 0. 62E+00 1. 30E+00 4. 63E+00 TM 15 61984 09/19/01 Ru-103 -2. 16E+00 1. 30E+00 5. 14E+00 TM 15 61984 09/19/01 Ru-106 1. 73E+01 1. 42E+01 4. 78E+01 TM 15 61984 09/19/01 Sb-124 0. OOE+00 3. 13E+00 1. 23E+01 TM 15 61984 09/19/01 Se-75 -0. 42E+00 1. 90E+00 6. 68E+00 TM 15 61984 09/19/01 Zn-65 -7. 13E+00 3. 95E+00 1. 56E+01 TM 15 61984 09/19/01 Zr-95 -3. 04E+00 2. 38E+00 9.4 6E+00 TM 15 62464 10/17/01 Th-232 4 .4 1E+00 5. 06E+00 1. 73E+01 TM 15 62464 10/17/01 Ag-11CM 0.21E+00 1. 58E+00 5. 72E+00 TM 15 62464 10/17/01 Ba-140 1. 14E+00 2. 19E+00 7.89E+00 TM 15 62464 10/17/01 Be-7 -4.25E+00 9.27E+00 3. 42E+01 TM 15 62464 10/17/01 Ce-141 3. 14E+00 2. 31E+00 7. 66E+00 TM 15 62464 10/17/01 Ce-144 5. 14E+00 7. 87E+00 2. 67E+01 TM 15 62464 10/17/01 Co-57 -0. 77E+00 1. 07E+00 3. 75E+00 TM 15 62464 10/17/01 Co-58 -0. 75E+00 1. 08E+00 4 .15E+00 TM 15 62464 10/17/01 Co-60 -0.39E+00 1.43E+00 5. 32E+00 TM 15 62464 10/17/01 Cr-51 2. 99E+00 1. 23E+01 4. 26E+01 TM 15 62464 10/17/01 Cs-134 -1. 99E-02 1. 13E+00 4. 17E+00 TM 15 62464 10/17/01 Cs-137 1.4 9E+00 1. 33E+00 4.50E+00 TM 15 62464 10/17/01 Fe-59 -6. 55E+00 4 . 50E+00 1.74E+01 TM 15 62464 10/17/01 1-131 5. 25E-02 8. 98E-02 0.4 9E+00 TM 15 62464 10/17/01 K-40 1. 54E+03 5. 69E+01 6.14E+01
- TM 15 62464 10/17/01 Mn-54 -1. 57E+00 1. 19E+00 4. 59E+00 TM 15 62464 10/17/01 Ru-103 -0.81E+00 1. 27E+00 4.68E+00 TM 15 62464 10/17/01 Ru-106 9. 67E+00 1. 16E+01 3. 99E+01 TM 15 62464 10/17/01 Sb-124 -0. 53E+00 2. 05E+00 8.41E+00 TM 15 62464 10/17/01 Se-75 2. 76E+00 1. 62E+00 5. 31E+00 TM 15 62464 10/17/01 Zn-65 -5. 19E+00 3. 88E+00 1.52E+01 TM 15 62464 10/17/01 Zr-95 0. 27E+00 1. 96E+00 7. 11E+00
- Concentration Greater than 3 Standard Deviations 97
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 15 62937 11/14/01 Th-232 -6. 23E+00 7. 36E+00 2.81E+01 TM 15 62937 11/14/01 Ag-11GM 2.20E+00 2. 26E+00 7. 80E+00 TM 15 62937 11/14/01 Ba-140 -3. 13E+00 2.42E+00 1.09E+01 TM 15 62937 11/14/01 Be-7 -3. 39E+00 1. 31E+01 4.84E+01 TM 15 62937 11/14/01 Ce-141 -0. 32E+00 2. 55E+00 8.89E+00 TM 15 62937 11/14/01 Ce-144 5. 07E+00 9. 57E+00 3.26E+01 TM 15 62937 11/14/01 Co-57 -1. 45E+00 1.21E+00 4.35E+00 TM 15 62937 11/14/01 Co-58 0. OOE+00 1. 67E+00 6. 20E+00 TM 15 62937 11/14/01 Co-60 3. 73E+00 1.80E+00 5. 52E+00 TM 15 62937 11/14/01 Cr-51 -2. 62E+01 1. 65E+01 6.17E+01 TM 15 62937 11/14/01 Cs-134 0. 77E+00 1.75E+00 6. 31E+00 TM 15 62937 11/14/01 Cs-137 2. 52E+00 1. 92E+00 6. 41E+00 TM 15 62937 11/14/01 Fe-59 4. 94E+00 5.86E+00 2. 05E+01 TM 15 62937 11/14/01 1-131 0.21E+00 0. 15E+00 0. 58E+00 TM 15 62937 11/14/01 K-40 1. 52E+03 7. 65E+01 6.53E+01
- TM 15 62937 11/14/01 Mn-54 0. 76E+00 1 . 77E+00 6. 31E+00 TM 15 62937 11/14/01 Ru-103 -1. 92E+00 1 . 85E+00 7. 01E+00 TM 15 62937 11/14/01 Ru-106 1. 18E+01 1. 48E+01 5. 14E+01 TM 15 62937 11/14/01 Sb-124 -2. 99E+00 2. 99E+00 1. 41E+01 TM 15 62937 11/14/01 Se-75 -1.22E+00 2. 20E+00 7. 87E+00 TM 15 62937 11/14/01 Zn-65 -3. 17E+00 4 16E+00 1. 62E+01 TM 15 62937 11/14/01 Zr-95 4. 10E+00 2. 70E+00 8. 90E+00 TM 15 63303 12/12/01 Th-232 -1. 42E+00 6. 20E+00 2. 34E+01 TM 15 63303 12/12/01 Ag-IIOM 6. 21E+00 2. 39E+00 7. 11E+00 TM 15 63303 12/12/01 Ba-140 -0. 59E+00 2. 44E+00 9. 86E+00 TM 15 63303 12/12/01 Be-7 -2 84E+01 1. 45E+01 5. 72E+01 TM 15 63303 12/12/01 Ce-141 0. 62E+00 2. 39E+00 8 .26E+00 TM 15 63303 12/12/01 Ce-144 8 74E+00 9. 63E+00 3. 24E+01 TM 15 63303 12/12/01 Co-57 2. 21E+00 1. 15E+00 3. 72E+00 TM 15 63303 12/12/01 Co-58 1. 15E+00 1. 57E+00 5. 54E+00 TM 15 63303 12/12/01 Co-60 -1.73E+00 1. 95E+00 7. 90E+00 TM 15 63303 12/12/01 Cr-51 -1. 56E+01 1.55E+01 5. 70E+01 TM 15 63303 12/12/01 Cs-134 -3. 12E+00 1 .77E+00 7. 34E+00 TM 15 63303 12/12/01 Cs-137 -1. 20E+00 1 .79E+00 6. 81E+00 TM 15 63303 12/12/01 Fe-59 -1. 62E+00 5. 22E+00 2. 02E+01 TM 15 63303 12/12/01 1-131 0. 11E+00 9. 87E-02 0. 43E+00 TM 15 63303 12/12/01 K-40 1. 32E+03 7.42E+01 9. 47E+01
- TM 15 63303 12/12/01 Mn-54 1.26E+00 1. 69E+00 5. 92E+00 TM 15 63303 12/12/01 Ru-103 -3. 15E+00 1. 66E+00 6. 66E+00 TM 15 63303 12/12/01 Ru-106 2. 68E+01 1. 67E+01 5. 48E+01 TM 15 63303 12/12/01 Sb-124 -3. 95E+00 4.19E+00 1. 79E+01 TM 15 63303 12/12/01 Se-75 -0. 69E+00 2. 06E+00 7. 33E+00 TM 15 63303 12/12/01 Zn-65 2.53E+00 4 . OOE+00 1. 42E+01 TM 15 63303 12/12/01 Zr-95 -6. 30E+00 2. 79E+00 1. 19E+01 TM 16 58094 01/11/01 Th-232 9. 46E+00 4. 61E+00 1. 47E+01
- Concentration Greater than 3 Standard Deviations 98
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 16 58094 01/11/01 Ag-IIOM 0. 76E+00 1.89E+00 6. 61E+00 TM 16 58094 01/11/01 Ba-140 0. 30E+00 1. 94E+00 7. 21E+00 TM 16 58094 01/11/01 Be-7 -2. 24E+01 1. 19E+01 4 46E+01 TM 16 58094 01/11/01 Ce-141 0. 43E+00 2. 76E+00 9.37E+00 TM 16 58094 01/11/01 Ce-144 -i.41E+01 9. 86E+00 3. 47E+01 TM 16 58094 01/11/01 Co-57 -0. 24E+00 1. 28E+00 4 .37E+00 TM 16 58094 01/11/01 Co-58 -1. 35E+00 1.43E+00 5. 31E+00 TM 16 58094 01/11/01 Co-60 3. 05E+00 1. 55E+00 4. 96E+00 TM 16 58094 01/11/01 Cr-51 0. OOE+00 1.37E+01 4. 76E+01 TM 16 58094 01/11/01 Cs-134 0 .41E+00 1.41E+00 4. 97E+00 TM 16 58094 01/11/01 Cs-137 -8. 61E-02 1.48E+00 5 22E+00 TM 16 58094 01/11/01 Fe-59 S. 14E+00 3. 88E+00 1.30E+01 TM 16 58094 01/11/01 1-131 9. 02E-02 9.23E-02 0. 42E+00 TM 16 58094 01/11/01 K-40 1. 83E+03 5. 91E+01 5 42E+01
- TM 16 58094 01/11/01 Mn-54 -i .24E+00 1. 17E+00 4 42E+00 TM 16 58094 01/11/01 Ru-103 -1. 1IE+00 1.45E+00 5 .26E+00 TM 16 58094 01/11/01 Ru-106 4.20E+00 1.08E+01 3. 79E+01 TM 16 58094 01/11/01 Sb-124 2. 93E+00 2. 59E+00 8. 87E+00 TM 16 58094 01/11/01 Se-75 1. 12E+00 1. 78E+00 6. 03E+00 TM 16 58094 01/11/01 Zn-65 -2. 09E+00 7.40E+00 2. 54E+01 TM 16 58094 01/11/01 Zr-95 -1. 72E+00 2.45E+00 9. 00E+00 TM 16 58596 02/14/01 Th-232 1. 01E+00 4. 53E+00 1. 61E+01 TM 16 58596 02/14/01 Ag-11GM -0. 19E+00 1.86E+00 6. 68E+00 TM 16 58596 02/14/01 Ba-140 0. 57E+00 1.22E+00 4.54E+00 TM 16 58596 02/14/01 Be-7 -5. 62E+00 1.03E+01 3. 71E+01 TM 16 58596 02/14/01 Ce-141 1. 02E+00 2. 13E+00 7 .23E+00 TM 16 58596 02/14/01 Ce-144 -1. 29E+01 8. 31E+00 2. 96E+01 TM 16 58596 02/14/01 Co-57 0. 41E+00 1. 05E+00 3. 57E+00 TM 16 58596 02/14/01 Co-58 0. 34E+00 1. 08E+00 3. 86E+00 TM 16 58596 02/14/01 Co-60 -0. 56E+00 1. 35E+00 5. 04E+00 TM 16 58596 02/14/01 Cr-51 1. 17E+01 1. 16E+01 3. 90E+01 TM 16 58596 02/14/01 Cs-134 1. 73E+00 1. 27E+00 4. 23E+00 TM 16 58596 02/14/01 Cs-137 3. 51E+00 1. 48E+00 4. 67E+00 TM 16 58596 02/14/01 Fe-59 8. 52E+00 3. 45E+00 1. 05E+01 TM 16 58596 02/14/01 1-131 0. 16E+00 0. 13E+00 0. 50E+00 TM 16 58596 02/14/01 K-40 1. 62E+03 5. 61E+01 5.70E+01
- TM 16 58596 02/14/01 Mn-54 -0. 33E+00 1. 10E+00 4. 03E+00 TM 16 58596 02/14/01 Ru-103 -i . 87E+00 1. 17E+00 4 .4 6E+00 TM 16 58596 02/14/01 Ru-106 5. 09E+00 1. 01E+01 3. 52E+01 TM 16 58596 02/14/01 Sb-124 -I .42E+00 2. 06E+00 8. 57E+00 TM 16 58596 02/14/01 Se-75 -0. 71E+00 1. 43E+00 5. 07E+00 TM 16 58596 02/14/01 Zn-65 1 .59E+00 7. 22E+00 2.45E+01 TM 16 58596 02/14/01 Zr-95 0. 20E+00 2 12E+00 7. 58E+00
- Concentration Greater than 3 Standard Deviations 99
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 16 58998 03/15/01 Th-232 3.48E+00 4. 75E+00 1. 63E+01 TM 16 58998 03/15/01 Ag-IIOM -0. 38E+00 1. 70E+00 6. 19E+00 TM 16 58998 03/15/01 Ba-140 -1. 99E+00 1.36E+00 5.88E+00 TM 16 58998 03/15/01 Be-7 2.79E+00 9. 34E+00 3.28E+01 TM 16 58998 03/15/01 Ce-141 -1. 38E+00 1.86E+00 6. 57E+00 TM 16 58998 03/15/01 Ce-144 6. 53E+00 7. 65E+00 2. 57E+01 TM 16 58998 03/15/01 Co-57 -1. 16E+00 0. 99E+00 3. 51E+00 TM 16 58998 03/15/01 Co-58 -0. 72E+00 1. 03E+00 3. 93E+00 TM 16 58998 03/15/01 Co-60 0. 96E+00 1. 33E+00 4. 64E+00 TM 16 58998 03/15/01 Cr-51 1. 83E+01 1. 12E+01 3. 68E+01 TM 16 58998 03/15/01 Cs-134 2. 09E+00 1.23E+00 4 . OOE+00 TM 16 58998 03/15/01 Cs-137 5. 29E+00 1. 35E+00 3. 86E+00
- TM 16 58998 03/15/01 Fe-59 4. 79E+00 4. 01E+00 1 . 35E+01 TM 16 58998 03/15/01 1-131 -1. 60E-02 3. 26E-02 0. 26E+00 TM 16 58998 03/15/01 K-40 1. 87E+03 5. 94E+01 5 28E+01
- TM 16 58998 03/15/01 Mn-54 -1. 73E+00 0. 92E+00 3. 75E+00 TM 16 58998 03/15/01 Ru-103 -1. 97E+00 1. 16E+00 4 43E+00 TM 16 58998 03/15/01 Ru-106 2. 53E+00 1. 02E+01 3. 60E+01 TM 16 58998 03/15/01 Sb-124 0 . OOE+00 2. 30E+00 8. 84E+00 TM 16 58998 03/15/01 Se-75 1. 77E+00 1. 44E+00 4 .79E+00 TM 16 58998 03/15/01 Zn-65 7. 17E+00 5. 68E+00 1.89E+01 TM 16 58998 03/15/01 Zr-95 -1. 62E+00 2. 14E+00 7 96E+00 TM 16 59444 04/11/01 Th-232 -4. 69E+00 4.42E+00 1. 69E+01 TM 16 59444 04/11/01 Ag-liOM 1. 02E+00 1. 74E+00 6. 08E+00 TM 16 59444 04/11/01 Ba-140 -1.23E+00 1. 15E+00 5. 10E+00 TM 16 59444 04/11/01 Be-7 5. 05E+00 8. 97E+00 3. 13E+01 TM 16 59444 04/11/01 Ce-141 0. 35E+00 2 . 07E+00 7. 10E+00 TM 16 59444 04/11/01 Ce-144 3. 76E+00 8.40E+00 2.86E+01 TM 16 59444 04/11/01 Co-57 -1. 49E+00 1. 02E+00 3. 66E+00 TM 16 59444 04/11/01 Co-58 2.80E+00 1.24E+00 3. 88E+00 TM 16 59444 04/11/01 Co-60 -1. 78E+00 1. 40E+00 5. 51E+00 TM 16 59444 04/11/01 Cr-51 -1. 44E+01 1. 16E+01 4.25E+01 TM 16 59444 04/11/01 Cs-134 1. 27E+00 1.23E+00 4. 21E+00 TM 16 59444 04/11/01 Cs-137 3. 76E+00 1. 97E+00 6. 39E+00 TM 16 59444 04/11/01 Fe-59 4. 68E+00 3.73E+00 1.25E+01 TM 16 59444 04/11/01 1-131 -2. 78E-02 7. 60E-02 0. 60E+00 TM 16 59444 04/11/01 K-40 1. 89E+03 6. 18E+01 5.34E+01
- TM 16 59444 04/11/01 Mn-54 -0. 99E+00 1. 24E+00 4. 65E+00 TM 16 59444 04/11/01 Ru-103 -1. 64E+00 1.27E+00 4.77E+00 TM 16 59444 04/11/01 Ru-106 -1. 53E+01 1. 14E+01 4. 30E+01 TM 16 59444 04/11/01 Sb-124 1. 01E+00 2. 15E+00 8. 03E+00 TM 16 59444 04/11/01 Se-75 1. 24E+00 1. 71E+00 5. 79E+00 TM 16 59444 04/11/01 Zn-65 -5. 47E+00 3. 52E+00 1. 34E+01 TM 16 59444 04/11/01 Zr-95 1.70E+00 1. 89E+00 6. 51E+00
- Concentration Greater than 3 Standard Deviations 100
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 16 59606 04/25/01 Th-232 2. 19E+00 6. 91E+00 2. 48E+01 TM 16 59606 04/25/01 Ag-11OM 1. 50E+00 2. 30E+00 8. 18E+00 TM 16 59606 04/25/01 Ba-140 6.69E+00 2. 68E+00 6. 90E+00 TM 16 59606 04/25/01 Be-7 1. 25E+01 1. 42E+01 4.87E+01 TM 16 59606 04/25/01 Ce-141 -1. 53E+00 2. 84E+00 1.OOE+01 TM 16 59606 04/25/01 Ce-144 0. 33E+00 1. 00E+01 3. 47E+01 TM 16 59606 04/25/01 Co-57 -2. 18E+00 1. 20E+00 4.40E+00 TM 16 59606 04/25/01 Co-58 0.21E+00 1. 68E+00 6. 22E+00 TM 16 59606 04/25/01 Co-60 -1. 34E+00 1. 93E+00 7.75E+00 TM 16 59606 04/25/01 Cr-51 -1. 91E+01 1. 58E+01 5. 92E+01 TM 16 59606 04/25/01 Cs-134 -0. 53E+00 1. 45E+00 5. 72E+00 TM 16 59606 04/25/01 Cs-137 -0. 12E+00 2. 00E+00 7. 28E+00 TM 16 59606 04/25/01 Fe-59 -2.4 9E+00 6. 72E+00 2. 54E+01 TM 16 59606 04/25/01 1-131 -5. 31E-02 3. 16E-02 0. 30E+00 TM 16 59606 04/25/01 K-40 1. 81E+03 8. 42E+01 7.56E+01
- TM 16 59606 04/25/01 Mn-54 -1. 03E+00 1. 74E+00 6. 68E+00 TM 16 59606 04/25/01 Ru-103 -0.4 6E+00 1. 85E+00 6. 80E+00 TM 16 59606 04/25/01 Ru-106 -1. 44E+01 1.71E+01 6. 44E+01 TM 16 59606 04/25/01 Sb-124 3. 14E+00 4. 05E+00 1. 47E+01 TM 16 59606 04/25/01 Se-75 4 .13E+00 2. 18E+00 7. 06E+00 TM 16 59606 04/25/01 Zn-65 4. 53E+00 4. 62E+00 1. 59E+01 TM 16 59606 04/25/01 Zr-95 3. 27E+00 3. 62E+00 1. 25E+01 TM 16 59891 05/09/01 Th-232 -5. 14E+00 4. 54E+00 1. 73E+01 TM 16 59891 05/09/01 Ag-11CM 0. 40E+00 1. 62E+00 5. 78E+00 TM 16 59891 05/09/01 Ba-140 2. 93E+00 1.87E+00 6. 11E+00 TM 16 59891 05/09/01 Be-7 2. 07E+00 1. 01E+01 3. 57E+01 TM 16 59891 05/09/01 Ce-141 2. 92E+00 2. 33E+00 7.73E+00 TM 16 59891 05/09/01 Ce-144 1. 84E+00 8. 19E+00 2. 80E+01 TM 16 59891 05/09/01 Co-57 0. 22E+00 1. 03E+00 3. 52E+00 TM 16 59891 05/09/01 Co-58 0. OOE+00 1. 28E+00 4. 63E+00 TM 16 59891 05/09/01 Co-60 -1. 26E+00 1. 29E+00 5. 02E+00 TM 16 59891 05/09/01 Cr-51 1. 85E+01 1. 19E+01 3. 94E+01 TM 16 59891 05/09/01 Cs-134 -0. 92E+00 1. 45E+00 S. 33E+00 TM 16 59891 05/09/01 Cs-137 2. 25E+00 1. 33E+00 4. 36E+00 TM 16 59891 05/09/01 Fe-59 -5. 06E-02 3. 56E+00 1. 31E+01 TM 16 59891 05/09/01 1-131 -4.76E-03 0. 12E+00 0. 89E+00 TM 16 59891 05/09/01 K-40 1. 58E+03 5. 64E+01 5.90E+01
- TM 16 59891 05/09/01 Mn-54 -0. 14E+00 1. 10E+00 4 . O1E+00 TM 16 59891 05/09/01 Ru-103 1. 31E+00 1. 30E+00 4.41E+00 TM 16 59891 05/09/01 Ru-106 -1. 91E+00 1. 05E+01 3. 81E+01 TM 16 59891 05/09/01 Sb-124 2. 20E+00 2. 31E+00 8. 14E+00 TM 16 59891 05/09/01 Se-75 1. 12E+00 1. 65E+00 5. 61E+00 TM 16 59891 05/09/01 Zn-65 -3. 17E+00 3. 58E+00 1. 32E+01 TM 16 59891 05/09/01 Zr-95 -1. 13E+00 1. 95E+00 7. 34E+00
- Concentration Greater than 3 Standard Deviations 101
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 16 60117 05/23/01 Th-232 3. 87E+00 4.79E+00 1. 65E+01 TM 16 60117 05/23/01 Ag-11CM 1.84E+00 2. O1E+00 6. 86E+00 TM 16 60117 05/23/01 Ba-140 -0. 65E+00 1. 65E+00 6.52E+00 TM 16 60117 05/23/01 Be-7 5. 12E+00 9. 76E+00 3. 40E+01 TM 16 60117 05/23/01 Ce-141 -0. 79E+00 2.21E+00 7. 68E+00 TM 16 60117 05/23/01 Ce-144 6.91E+00 7. 98E+00 2. 68E+01 TM 16 60117 05/23/01 Co-57 0. 69E+00 1. 04E+00 3. 50E+00 TM 16 60117 05/23/01 Co-58 -0. 60E+00 1. 18E+00 4 40E+00 TM 16 60117 05/23/01 Co-60 -1. 18E+00 1. 41E+00 5. 41E+00 TM 16 60117 05/23/01 Cr-51 -1. 48E+01 1. 16E+01 4. 27E+01 TM 16 60117 05/23/01 Cs-134 9. 92E-02 1. 24E+00 4 . 50E+00 TM 16 60117 05/23/01 Cs-137 3. 25E+00 1. 71E+00 5 . 55E+00 TM 16 60117 05/23/01 Fe-59 -2. 06E+00 4. 33E+00 1. 60E+01 TM 16 60117 05/23/01 1-131 0. 17E+00 0. 18E+00 0. 81E+00 TM 16 60117 05/23/01 K-40 1. 98E+03 6. 39E+01 6.23E+01
- TM 16 60117 05/23/01 Mn-54 -0. 71E+00 1. 28E+00 4 .71E+00 TM 16 60117 05/23/01 Ru-103 -1. 41E+00 1. 34E+00 4. 98E+00 TM 16 60117 05/23/01 Ru-106 -1. 45E+01 1. 08E+01 4.12E+01 TM 16 60117 05/23/01 Sb-124 -5. 63E+00 1. 98E+00 9. 98E+00 TM 16 60117 05/23/01 Se-75 1. 81E+00 1. 77E+00 5. 95E+00 TM 16 60117 05/23/01 Zn-65 4.46E+00 4. 20E+00 1.35E+01 TM 16 60117 05/23/01 Zr-95 -2.14E+00 1. 91E+00 7.44E+00 TM 16 60420 06/06/01 Th-232 -0. 41E+00 4. 86E+00 1.75E+01 TM 16 60420 06/06/01 Ag-11OM 1. 04E+00 1.70E+00 5. 94E+00 TM 16 60420 06/06/01 Ba-140 -0. 45E+00 1. 95E+00 7.79E+00 TM 16 60420 06/06/01 Be-7 4 .42E+00 1. 09E+01 3. 82E+01 TM 16 60420 06/06/01 Ce-141 -0. 64E+00 2. 40E+00 8. 33E+00 TM 16 60420 06/06/01 Ce-144 9. 08E+00 8. 45E+00 2. 82E+01 TM 16 60420 06/06/01 Co-57 -1. 20E+00 1. 10E+00 3. 89E+00 TM 16 60420 06/06/01 Co-58 -1. 97E+00 1.24E+00 4. 92E+00 TM 16 60420 06/06/01 Co-60 -1. 52E+00 1. 32E+00 5. 22E+00 TM 16 60420 06/06/01 Cr-51 2. 15E+00 1. 27E+01 4.44E+01 TM 16 60420 06/06/01 Cs-134 0. 42E+00 1. 27E+00 4. 52E+00 TM 16 60420 06/06/01 Cs-137 3. 13E+00 1. 63E+00 5.26E+00 TM 16 60420 06/06/01 Fe-59 -3. 84E+00 4.58E+00 1. 73E+01 TM 16 60420 06/06/01 1-131 -2.4 9E-02 0. 11E+00 0. 70E+00 TM 16 60420 06/06/01 K-40 1. 92E+03 6.25E+01 5.52E+01
- TM 16 60420 06/06/01 Mn-54 -1.29E+00 1.21E+00 4. 62E+00 TM 16 60420 06/06/01 Ru-103 -0.29E+00 1. 29E+00 4. 69E+00 TM 16 60420 06/06/01 Ru-106 2. 78E+00 1. 02E+01 3. 62E+01 TM 16 60420 06/06/01 Sb-124 0. 55E+00 2. 39E+00 9. 14E+00 TM 16 60420 06/06/01 Se-75 1. 99E+00 1. 72E+00 5.76E+00 TM 16 60420 06/06/01 Zn-65 -1. 40E+00 3. 04E+00 1. 12E+01 TM 16 60420 06/06/01 Zr-95 -0. 90E+00 2. 13E+00 7. 93E+00
- Concentration Greater than 3 Standard Deviations 102
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 16 60617 06/20/01 Th-232 9.04E-02 3. 72E+00 1.30E+01 TM 16 60617 06/20/01 Ag-IIOM -0.33E+00 1. 33E+00 4.71E+00 TM 16 60617 06/20/01 Ba-140 -0. 86E+00 1. 53E+00 5.81E+00 TM 16 60617 06/20/01 Be-7 0.58E+00 8. 00E+00 2.78E+01 TM 16 60617 06/20/01 Ce-141 -3. 05E+00 1. 80E+00 6.30E+00 TM 16 60617 06/20/01 Ce-144 2. 58E+00 6. 21E+00 2. 09E+01 TM 16 60617 06/20/01 Co-57 -0.74E+00 0.78E+00 2.71E+00 TM 16 60617 06/20/01 Co-58 -0.26E+00 0. 98E+00 3.49E+00 TM 16 60617 06/20/01 Co-60 -1. 16E+00 0. 97E+00 3. 66E+00 TM 16 60617 06/20/01 Cr-51 -6. 02E+00 9. 59E+00 3.36E+01 TM 16 60617 06/20/01 Cs-134 0. 53E+00 0. 96E+00 3.31E+00 TM 16 60617 06/20/01 Cs-137 3.7 6E+00 1. 30E+00 4. 10E+00 TM 16 60617 06/20/01 Fe-59 3. 70E+00 3. 22E+00 1.08E+01 TM 16 60617 06/20/01 1-131 -8. 07E-02 0. 11E+00 0.94E+00 TM 16 60617 06/20/01 K-40 1. 95E+03 4. 57E+01 3.50E+01
- TM 16 60617 06/20/01 Mn-54 -0. 15E+00 0. 98E+00 3. 44E+00 TM 16 60617 06/20/01 Ru-103 -1. 84E+00 1. 04E+00 3. 83E+00 TM 16 60617 06/20/01 Ru-106 5. 07E+00 8. 73E+00 2.98E+01 TM 16 60617 06/20/01 Sb-124 -0.8 6E+00 1. 69E+00 6.58E+00 TM 16 60617 06/20/01 Se-75 -1.73E+00 1. 28E+00 4.51E+00 TM 16 60617 06/20/01 Zn-65 0. 74E+00 2. 96E+00 1. 01E+01 TM 16 60617 06/20/01 Zr-95 1.8 6E+00 1.73E+00 5. 81E+00 TM 16 60915 07/11/01 Th-232 -4. 69E+00 4. 97E+00 1. 86E+01 TM 16 60915 07/11/01 Ag-IIOM -2. 04E+00 1. 83E+00 6. 93E+00 TM 16 60915 07/11/01 Ba-140 1. 30E+00 1.52E+00 5. 40E+00 TM 16 60915 07/11/01 Be-7 -5. 12E+00 1. 12E+01 4. 03E+01 TM 16 60915 07/11/01 Ce-141 -0. 93E+00 2.33E+00 8. 07E+00 TM 16 60915 07/11/01 Ce-144 1. 01E+01 8. 89E+00 2. 96E+01 TM 16 60915 07/11/01 Co-57 -0. 57E+00 1. 18E+00 4. 08E+00 TM 16 60915 07/11/01 Co-58 -3. 37E+00 1.31E+00 5. 30E+00 TM 16 60915 07/11/01 Co-60 2. 57E+00 1.53E+00 5. 00E+00 TM 16 60915 07/11/01 Cr-51 7 .41E+00 1.26E+01 4. 29E+01 TM 16 60915 07/11/01 Cs-134 -0. 32E+00 1.39E+00 5.06E+00 TM 16 60915 07/11/01 Cs-137 2. 16E+00 1. 03E+00 3. 27E+00 TM 16 60915 07/11/01 Fe-59 3. 32E+00 4.22E+00 1. 46E+01 TM 16 60915 07/11/01 1-131 -3. 42E-02 6.81E-02 0. 56E+00 TM 16 60915 07/11/01 K-40 1. 92E+03 6.26E+01 5.65E+01
- TM 16 60915 07/11/01 Mn-54 -1. 99E+00 1. 30E+00 5. OOE+00 TM 16 60915 07/11/01 Ru-103 0. 13E+00 1.29E+00 4. 57E+00 TM 16 60915 07/11/01 Ru-106 1. 04E+01 1. 10E+01 3. 75E+01 TM 16 60915 07/11/01 Sb-124 2. 56E+00 2. 35E+00 8.13E+00 TM 16 60915 07/11/01 Se-75 -2. 83E+00 1.85E+00 6. 67E+00 TM 16 60915 07/11/01 Zn-65 -5. 09E+00 7.26E+00 2.52E+01 TM 16 60915 07/11/01 Zr-95 -3. 18E+00 2. 06E+00 8. 11E+00
- Concentration Greater than 3 Standard Deviations 103
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 16 61172 07/25/01 Th-232 -5. 22E+00 5. 39E+00 2.OOE+01 TM 16 61172 07/25/01 Ag-IIOM 0. 61E+00 1. 83E+00 6. 47E+00 TM 16 61172 07/25/01 Ba-140 0. 31E+00 1. 41E+00 5. 37E+00 TM 16 61172 07/25/01 Be-7 -7. 08E+00 8. 99E+00 3. 36E+01 TM 16 61172 07/25/01 Ce-141 -0. 22E+00 2. 16E+00 7.45E+00 TM 16 61172 07/25/01 Ce-144 -2. 59E+00 8. 29E+00 2.88E+01 TM 16 61172 07/25/01 Co-57 -0. 69E+00 1. 08E+00 3. 78E+00 TM 16 61172 07/25/01 Co-58 2. 41E+00 1.26E+00 4. 05E+00 TM 16 61172 07/25/01 Co-60 1 .25E+00 1. 42E+00 4. 89E+00 TM 16 61172 07/25/01 Cr-51 -8 14E+00 1. 17E+01 4. 19E+01 TM 16 61172 07/25/01 Cs-134 -0. 73E+00 1.29E+00 4 .81E+00 TM 16 61172 07/25/01 Cs-137 4. 75E+00 1.76E+00 5. 53E+00 TM 16 61172 07/25/01 Fe-59 7. 03E+00 4.57E+00 1.51E+01 TM 16 61172 07/25/01 1-131 0. 15E+00 0. 13E+00 0. 55E+00 TM 16 61172 07/25/01 K-40 2. 00E+03 6. 38E+01 5.65E+01 TM 16 61172 07/25/01 Mn-54 -1. 98E+00 1. 30E+00 4. 99E+00 TM 16 61172 07/25/01 Ru-103 -1. 52E+00 1. 21.E+00 4. 58E+00 TM 16 61172 07/25/01 Ru-106 7. 06E+00 1. 06E+01 3. 69E+01 TM 16 61172 07/25/01 Sb-124 -1. 52E+00 2. 53E+00 1.02E+01 TM 16 61172 07/25/01 Se-75 -0. 90E+00 1 . 65E+00 5. 82E+00 TM 16 61172 07/25/01 Zn-65 2. 39E+00 3.33E+00 1. 15E+01 TM 16 61172 07/25/01 Zr-95 -1. 12E+00 2 .14E+00 7. 95E+00 TM 16 61371 08/08/01 Th-232 5.46E+00 5. 04E+00 1.71E+01 TM 16 61371 08/08/01 Ag-IIOM 0.20E+00 1. 69E+00 6. 08E+00 TM 16 61371 08/08/01 Ba-140 3. 23E+00 1.58E+00 4.85E+00 TM 16 61371 08/08/01 Be-7 0. OOE+00 9.4 6E+00 3. 39E+01 TM 16 61371 08/08/01 Ce-141 6. 28E+00 2 . 20E+00 6. 98E+00 TM 16 61371 08/08/01 Ce-144 6. 81E+00 8. 31E+00 2. 80E+01 TM 16 61371 08/08/01 Co-57 2. 17E+00 1. 11E+00 3. 62E+00 TM 16 61371 08/08/01 Co-58 1.38E+00 1. 08E+00 3. 61E+00 TM 16 61371 08/08/01 Co-60 0. 86E+00 1.39E+00 4. 88E+00 TM 16 61371 08/08/01 Cr-51 1.85E+00 1. 16E+01 4. 04E+01 TM 16 61371 08/08/01 Cs-134 -0. 36E+00 1. 23E+00 4. 54E+00 TM 16 61371 08/08/01 Cs-137 4 16E+00 1.81E+00 5.78E+00 TM 16 61371 08/08/01 Fe-59 8 48E+00 4. 30E+00 1.38E+01 TM 16 61371 08/08/01 1-131 0. 16E+00 0. 16E+00 0.75E+00 TM 16 61371 08/08/01 K-40 1. 96E+03 6.34E+01 6.03E+01 TM 16 61371 08/08/01 Mn-54 -1. 13E+00 1. 28E+00 4. 80E+00 TM 16 61371 08/08/01 Ru-103 -1. 15E+00 1. 33E+00 4. 89E+00 TM 16 61371 08/08/01 Ru-106 -1. 29E+01 1. 15E+01 4. 30E+01 TM 16 61371 08/08/01 Sb-124 1. 53E+00 2. 1]E+00 7. 67E+00 TM 16 61371 08/08/01 Se-75 0. 68E+00 1. 82E+00 6. 22E+00 TM 16 61371 08/08/01 Zn-65 -7. 52E+00 3. 78E+00 1.44E+01 TM 16 61371 08/08/01 Zr-95 -1. 13E+00 2. 15E+00 8.01E+00
- Concentration Greater than 3 Standard Deviations 104
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 16 61551 08/22/01 Th-232 5. 32E+00 7. 36E+00 2. 57E+01 TM 16 61551 08/22/01 Ag-11OM 0. 37E+00 2.54E+00 9. 27E+00 TM 16 61551 08/22/01 Ba-140 1. 57E+00 3. 33E+00 1.25E+01 TM 16 61551 08/22/01 Be-7 1. 79E+00 1. 28E+01 4. 64E+01 TM 16 61551 08/22/01 Ce-141 1. 29E+00 3. 10E+00 1. 06E+01 TM 16 61551 08/22/01 Ce-144 -5. O1E+00 9.75E+00 3. 44E+01 TM 16 61551 08/22/01 Co-57 1. 35E+00 1.36E+00 4. 56E+00 TM 16 61551 08/22/01 Co-58 -1. 45E+00 1. 83E+00 7. 13E+00 TM 16 61551 08/22/01 Co-60 -2. 73E+00 2.31E+00 9. 27E+00 TM 16 61551 08/22/01 Cr-51 -1.29E+01 1. 81E+01 6. 59E+01 TM 16 61551 08/22/01 Cs-134 4. 86E+00 1. 93E+00 5. 80E+00 TM 16 61551 08/22/01 Cs-137 -3. 33E+00 2. 08E+00 8. 09E+00 TM 16 61551 08/22/01 Fe-59 -8. 79E+00 6. 65E+00 2. 67E+01 TM 16 61551 08/22/01 1-131 7. 23E-02 0. 11E+00 0. 55E+00 TM 16 61551 08/22/01 K-40 2. 03E+03 8. 90E+01 8.18E+01
- TM 16 61551 08/22/01 Mn-54 -2. 55E+00 1. 84E+00 7. 29E+00 TM 16 61551 08/22/01 Ru-103 0. 92E+00 1. 92E+00 6.77E+00 TM 16 61551 08/22/01 Ru-106 0. 34E+00 1.74E+01 6.28E+01 TM 16 61551 08/22/01 Sb-124 -3. 14E+00 4.80E+00 1. 97E+01 TM 16 61551 08/22/01 Se-75 3. 02E+00 2. 30E+00 7. 65E+00 TM 16 61551 08/22/01 Zn-65 -7. 69E+00 5. 52E+00 2. 13E+01 TM 16 61551 08/22/01 Zr-95 3. 63E+00 3. 09E+00 1.05E+01 TM 16 61800 09/05/01 Th-232 0. 24E+00 8. 53E+00 3. 07E+01 TM 16 61800 09/05/01 Ag-IIOM -4 .82E+00 2. 65E+00 1. 08E+01 TM 16 61800 09/05/01 Ba-140 0. 60E+00 2. 77E+00 1. 05E+01 TM 16 61800 09/05/01 Be-7 1.70E+00 1. 39E+01 5. 01E+01 TM 16 61800 09/05/01 Ce-141 0.26E+00 2. 7 6E+00 9.54E+00 TM 16 61800 09/05/01 Ce-144 -0.22E+00 1. 09E+01 3. 76E+01 TM 16 61800 09/05/01 Co-57 0. 99E+00 1. 33E+00 4. 51E+00 TM 16 61800 09/05/01 Co-58 -2. 81E+00 2. 10E+00 8.19E+00 TM 16 61800 09/05/01 Co-60 -1. 57E+00 2. 30E+00 8. 96E+00 TM 16 61800 09/05/01 Cr-51 -1.88E+01 1. 59E+01 5. 91E+01 TM 16 61800 09/05/01 Cs-134 0. 14E+00 1. 94E+00 7. 12E+00 TM 16 61800 09/05/01 Cs-137 -8. 14E-02 2. 19E+00 7. 88E+00 TM 16 61800 09/05/01 Fe-59 -1.18E+01 8. 08E+00 3. 13E+01 TM 16 61800 09/05/01 1-131 -4.37E-03 8. 90E-02 0. 65E+00 TM 16 61800 09/05/01 K-40 2 . 05E+03 8 88E+01 6.25E+01
- TM 16 61800 09/05/01 Mn-54 -0.26E+00 2. 06E+00 7. 53E+00 TM 16 61800 09/05/01 Ru-103 0.21E+00 1. 80E+00 6.4 6E+00 TM 16 61800 09/05/01 Ru-106 -0. 68E+00 1. 65E+01 6.01E+01 TM 16 61800 09/05/01 Sb-124 -2.01E+00 2. 84E+00 1. 31E+01 TM 16 61800 09/05/01 Se-75 0. OOE+00 2. 20E+00 7.71E+00 TM 16 61800 09/05/01 Zn-65 -3.85E+00 4. 35E+00 1.70E+01 TM 16 61800 09/05/01 Zr-95 -2.4 6E+00 2. 97E+00 1.16E+01
- Concentration Greater than 3 Standard Deviations 105
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 16 61985 09/19/01 Th-232 -7.55E+00 7.31E+00 2. 83E+01 TM 16 61985 09/19/01 Ag-IIOM -3.71E+00 2. 52E+00 1.01E+01 TM 16 61985 09/19/01 Ba-140 2. 56E+00 2. 72E+00 9. 61E+00 TM 16 61985 09/19/01 Be-7 -6. 88E+00 1.26E+01 4.78E+01 TM 16 61985 09/19/01 Ce-141 -6. 87E+00 2. 68E+00 1.OOE+01 TM 16 61985 09/19/01 Ce-144 -1.72E+01 9. 56E+00 3. 51E+01 TM 16 61985 09/19/01 Co-57 -2. 26E+00 1. 33E+00 4. 80E+00 TM 16 61985 09/19/01 Co-58 -1. 48E+00 1. 71E+00 6. 73E+00 TM 16 61985 09/19/01 Co-60 1. 70E+00 2 05E+00 7.21E+00 TM 16 61985 09/19/01 Cr-51 1. 93E+01 1. 69E+01 5. 66E+01 TM 16 61985 09/19/01 Cs-134 -3. 48E+00 1. 73E+00 7.33E+00 TM 16 61985 09/19/01 Cs-137 6. 25E+00 2. 60E+00 8. 21E+00 TM 16 61985 09/19/01 Fe-59 4.42E+00 5. 32E+00 1. 87E+01 TM 16 61985 09/19/01 1-131 3. 24E-02 7. 57E-02 0. 41E+00 TM 16 61985 09/19/01 K-40 1. 89E+03 8. 70E+01 8.98E+01
- TM 16 61985 09/19/01 Mn-54 -2. 30E+00 1. 96E+00 7. 63E+00 TM 16 61985 09/19/01 Ru-103 -2. 61E+00 1. 74E+00 6. 82E+00 TM 16 61985 09/19/01 Ru-106 4.77E+00 1. 34E+01 4.83E+01 TM 16 61985 09/19/01 Sb-124 -2. 03E+00 3. 20E+00 1. 43E+01 TM 16 61985 09/19/01 Se-75 -0. 88E+00 2. 13E+00 7. 60E+00 TM 16 61985 09/19/01 Zn-65 -8. 98E+00 4 .80E+00 1. 94E+01 TM 16 61985 09/19/01 Zr-95 0. 12E+00 3.4 6E+00 1. 26E+01 TM 16 62465 10/17/01 Th-232 -3. 59E+00 5. 12E+00 1. 89E+01 TM 16 62465 10/17/01 Ag-11CM -0. 40E+00 1. 67E+00 6. 10E+00 TM 16 62465 10/17/01 Ba-140 1. 47E+00 1. 64E+00 S. 83E+00 TM 16 62465 10/17/01 Be-7 -1. 45E+01 1. OOE+01 3. 81E+01 TM 16 62465 10/17/01 Ce-141 1. 37E+00 2. 57E+00 8. 69E+00 TM 16 62465 10/17/01 Ce-144 8. 99E+00 8. 78E+00 2. 94E+01 TM 16 62465 10/17/01 Co-57 0. 15E+00 1. 10E+00 3.76E+00 TM 16 62465 10/17/01 Co-58 -2. 39E+00 1. 27E+00 S. 01E+00 TM 16 62465 10/17/01 Co-60 -1. 95E+00 1. 31E+00 5. 23E+00 TM 16 62465 10/17/01 Cr-51 2. 92E+00 1. 27E+01 4. 39E+01 TM 16 62465 10/17/01 Cs-134 -0. 92E+00 1. 45E+00 5. 33E+00 TM 16 62465 10/17/01 Cs-137 1. 30E+01 2. 08E+00 5.67E+00
- TM 16 62465 10/17/01 Fe-59 -5. 36E+00 4. 07E+00 1. 58E+01 TM 16 62465 10/17/01 1-131 7.48E-03 7. 57E-02 0. 53E+00 TM 16 62465 10/17/01 K-40 2. 02E+03 6. 30E+01 5. 58E+01 TM 16 62465 10/17/01 Mn-54 0.4 1E+00 1.21E+00 4. 28E+00 TM 16 62465 10/17/01 Ru-103 -1. 45E+00 1. 40E+00 5. 17E+00 TM 16 62465 10/17/01 Ru-106 1. 47E+01 1. 10E+01 3. 66E+01 TM 16 62465 10/17/01 Sb-124 -1. 28E+00 2. 90E+00 1. 13E+01 TM 16 62465 10/17/01 Se-75 -0.56E+00 1. 69E+00 5. 92E+00 TM 16 62465 10/17/01 Zn-65 -2. 38E+00 3. 51E+00 1.28E+01 TM 16 62465 10/17/01 Zr-95 1. 30E+00 2. 37E+00 8.27E+00
- Concentration Greater than 3 Standard Deviations 106
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 16 62938 11/14/01 Th-232 2. 80E+00 4. 55E+00 1.59E+01 TM 16 62938 11/14/01 Ag-ilOM -1. 02E+00 1. 82E+00 6. 71E+00 TM 16 62938 11/14/01 Ba-140 -1.29E+00 1.71E+00 6. 88E+00 TM 16 62938 11/14/01 Be-7 0. OOE+00 1. 08E+01 3. 84E+01 TM 16 62938 11/14/01 Ce-141 -3. 34E+00 2. 08E+00 7.51E+00 TM 16 62938 11/14/01 Ce-144 4. 87E+00 7. 74E+00 2. 63E+01 TM 16 62938 11/14/01 Co-57 -0. 84E+00 1.09E+00 3. 81E+00 TM 16 62938 11/14/01 Co-58 -0.71E+00 1. 20E+00 4.49E+00 TM 16 62938 11/14/01 Co-60 1. 30E+00 1.36E+00 4. 67E+00 TM 16 62938 11/14/01 Cr-51 3. 70E+00 1. 19E+01 4 .12E+01 TM 16 62938 11/14/01 Cs-134 0. 20E+00 1. 20E+00 4. 33E+00 TM 16 62938 11/14/01 Cs-137 9. 05E+00 1.89E+00 S.39E+00
- TM 16 62938 11/14/01 Fe-59 -9. 44E+00 4.31E+00 1.72E+01 TM 16 62938 11/14/01 1-131 0.26E+00 0. 17E+00 0. 59E+00 TM 16 62938 11/14/01 K-40 2. 11E+03 6.4 9E+01 4.76E+01
- TM 16 62938 11/14/01 Mn-54 0. 14E+00 1.31E+00 4. 66E+00 TM 16 62938 11/14/01 Ru-103 -0. 51E+00 1. 19E+00 4. 35E+00 TM 16 62938 11/14/01 Ru-106 1. 77E+00 9. 84E+00 3. 52E+01 TM 16 62938 11/14/01 Sb-124 -2. 56E+00 2.23E+00 9. 63E+00 TM 16 62938 11/14/01 Se-75 0. 57E+00 1. 61E+00 5. 54E+00 TM 16 62938 11/14/01 Zn-65 -1.71E+00 3. 68E+00 1. 33E+01 TM 16 62938 11/14/01 Zr-95 0.23E+00 1. 86E+00 6. 78E+00 TM 16 63304 12/12/01 Th-232 9.22E+00 5.20E+00 1. 69E+01 TM 16 63304 12/12/01 Ag-lIOM -0.81E+00 1. 82E+00 6. 69E+00 TM 16 63304 12/12/01 Ba-140 2. 75E+00 1. 53E+00 4 .85E+00 TM 16 63304 12/12/01 Be-7 1. 72E+01 1. 10E+01 3. 63E+01 TM 16 63304 12/12/01 Ce-141 -1. 77E+00 2. 12E+00 7.48E+00 TM 16 63304 12/ 12/01 Ce-144 -3. 92E+00 8.39E+00 2. 92E+01 TM 16 63304 12/12/01 Co-57 0. 32E+00 1. 04E+00 3. 55E+00 TM 16 63304 12/12/01 Co-58 -0. 76E+00 1.26E+00 4. 68E+00 TM 16 63304 12/12/01 Co-60 2. 84E+00 1. 69E+00 5. 51E+00 TM 16 63304 12/12/01 Cr-51 -2. 07E+01 1. 11E+01 4 .18E+01 TM 16 63304 12/12/01 Cs-134 0. 85E+00 1.26E+00 4. 38E+00 TM 16 63304 12/12/01 Cs-137 7. 24E+00 2.09E+00 6.39E+00
- TM 16 63304 12/12/01 Fe-59 0 . 00E+00 3.73E+00 1. 36E+01 TM 16 63304 12/12/01 1-131 7. 06E-02 0. 12E+00 0. 64E+00 TM 16 63304 12/12/01 K-40 1. 94E+03 6. 32E+01 5.95E+01
- TM 16 63304 12/12/01 Mn-54 0. 14E+00 1. 14E+00 4. 11E+00 TM 16 63304 12/12/01 Ru-103 -2. 27E+00 1.27E+00 4.88E+00 TM 16 63304 12/12/01 Ru-106 1. 18E+00 1.22E+01 4. 30E+01 TM 16 63304 12/12/01 Sb-124 -2. 02E+00 2 . 77E+00 1. 11E+01 TM 16 63304 12/12/01 Se-75 -0. 90E+00 1.71E+00 6. 03E+00 TM 16 63304 12/12/01 Zn-65 2. 05E+00 2 . 98E+00 1. 03E+01 TM 16 63304 12/12/01 Zr-95 1.70E+00 2. 10E+00 7. 26E+00
- Concentration Greater than 3 Standard Deviations 107
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 20 58095 01/10/01 Th-232 8.21E+00 7 .04E+00 2. 38E+01 TM 20 58095 01/10/01 Ag-IlOM 1. 11E+00 2. 69E+00 9. 59E+00 TM 20 58095 01/10/01 Ba-140 2. 23E+00 3. 23E+00 1. 18E+01 TM 20 58095 01/10/01 Be-7 1.4 1E+01 1. 37E+01 4. 66E+01 TM 20 58095 01/10/01 Ce-141 0. 64E+00 2.83E+00 9. 75E+00 TM 20 58095 01/10/01 Ce-144 -9. 05E+00 1. 03E+01 3. 65E+01 TM 20 58095 01/10/01 Co-57 -0. 66E+00 1. 27E+00 4 .4 6E+00 TM 20 58095 01/10/01 Co-58 1. 81E+00 1. 75E+00 6.03E+00 TM 20 58095 01/10/01 Co-60 3. 60E+00 2. 04E+00 6. 54E+00 TM 20 58095 01/10/01 Cr-51 -2. 36E+01 1. 60E+01 6.05E+01 TM 20 58095 01/10/01 Cs-134 2. 96E+00 1. 85E+00 6.07E+00 TM 20 58095 01/10/01 Cs-137 2. 32E+00 1. 87E+00 6.27E+00 TM 20 58095 01/10/01 Fe-59 -1.73E+00 5. 57E+00 2. 15E+01 TM 20 58095 01/10/01 1-131 4.43E-02 9. 86E-02 0. 52E+00 TM 20 58095 01/10/01 K-40 1.33E+03 7. 26E+01 7.71E+01
- TM 20 58095 01/10/01 Mn-54 2. 03E+00 1. 7 6E+00 5. 97E+00 TM 20 58095 01/10/01 Ru-103 -2.26E+00 1. 78E+00 6. 91E+00 TM 20 58095 01 /10/01 Ru-106 1.73E+01 1. 59E+01 5. 4 1E+01 TM 20 58095 01 /10/01 Sb-124 5 .18E+00 3. 11E+00 9. 61E+00 TM 20 58095 01 /10/01 Se-75 4. 07E+00 2. 23E+00 7.26E+00 TM 20 58095 01 /10/01 Zn-65 -3. 84E+00 5. 19E+00 1. 96E+01 TM 20 58095 01 /10/01 Zr-95 -3. 83E*00 2. 56E+00 1.08E+01 TM 20 58597 02 /14/01 Th-232 6. 63E+00 4. 94E+00 1. 64E+01 TM 20 58597 02 /14/01 Ag-IlOM -0. 27E+00 1. 52E+00 5.41E+00 TM 20 58597 02 /14/01 Ba-140 1 51E+00 1. 66E+00 5. 70E+00 TM 20 58597 02 /14/01 Be-7 -1. 35E+01 9. 25E+00 3. 37E+01 TM 20 58597 02 /14/01 Ce-141 2. 67E+00 1. 58E+00 5. 20E+00 TM 20 58597 02 /14/01 Ce-144 -2. 63E+00 5. 89E+00 2. 03E+01 TM 20 58597 02 /14/01 Co-57 -1. 80E+00 0. 7 6E+00 2. 73E+00 TM 20 58597 02 /14/01 Co-58 -0. 43E+00 1. 08E+00 3. 90E+00 TM 20 58597 02 /14/01 Co-60 -1. 19E+00 1. 23E+00 4.60E+00 TM 20 58597 02 /14/01 Cr-51 -2. 18E+01 1. O1E+01 3. 67E+01 TM 20 58597 02 /14/01 Cs-134 -0. 98E+00 1. 13E+00 4. 15E+00 TM 20 58597 02 /14/01 Cs-137 2 .22E+00 1. 23E+00 4 . OOE+00 TM 20 58597 02 /14/01 Fe-59 0. 59E+00 3. 42E+00 1.21E+01 TM 20 58597 02 /14/01 1-131 -5.43E-02 7 46E-02 0. 64E+00 TM 20 58597 02 /14/01 K-40 1. 30E+03 4 46E+01 5.77E+01
- TM 20 58597 02 /14/01 Mn-54 1. 11E+00 1 O1E+00 3. 39E+00 TM 20 58597 02 /14/01 Ru-103 -3.22E+00 1. 33E+00 4. 90E+00 TM 20 58597 02 /14/01 Ru-106 2.28E+00 1. 04E+01 3. 59E+01 TM 20 58597 02 /14/01 Sb-124 -1. 06E+00 2. 22E+00 8. 52E+00 TM 20 58597 02 /14/01 Se-75 0. 63E+00 1 . 20E+00 4. 07E+00 TM 20 58597 02 /14/01 Zn-65 -0.4 6E+00 2 80E+00 9. 90E+00 TM 20 58597 02 /14/01 Zr-95 -1. 97E+00 1. 96E+00 7. 18E+00
- Concentration Greater than 3 Standard Deviations 108
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 20 58999 03/14/01 Th-232 -4 44E+00 3. 50E+00 1. 38E+01 TM 20 58999 03/14/01 Ag-lIOM -1. 69E+00 1. 47E+00 5. 69E+00 TM 20 58999 03/14/01 Ba-140 3. 14E+00 1.59E+00 4. 97E+00 TM 20 58999 03/14/01 Be-7 0. 93E+00 8. 98E+00 3. 19E+01 TM 20 58999 03/14/01 Ce-141 -0. 69E+00 1. 83E+00 6. 41E+00 TM 20 58999 03/14/01 Ce-144 6.53E+00 7. 06E+00 2. 37E+01 TM 20 58999 03/14/01 Co-57 -0 80E+00 0. 96E+00 3. 38E+00 TM 20 58999 03/14/01 Co-58 2. 14E+00 1. 09E+00 3. 48E+00 TM 20 58999 03/14/01 Co-60 -2. 92E+00 1.24E+00 5. 19E+00 TM 20 58999 03/14/01 Cr-51 6. 66E+00 1. 01E+01 3. 44E+01 TM 20 58999 03/14/01 Cs-134 -0. 51E+00 1.09E+00 4 . 10E+00 TM 20 58999 03/14/01 Cs-137 1. 65E+00 1. 12E+00 3. 71E+00 TM 20 58999 03/14/01 Fe-59 4. 65E+00 3. 94E+00 1.33E+01 TM 20 58999 03/14/01 1-131 -1.72E-02 7. 61E-02 0.59E+00 TM 20 58999 03/14/01 K-40 1.36E+03 5. 13E+01 5.28E+01
- TM 20 58999 03/14/01 Mn-54 4. 90E-02 0. 99E+00 3. 61E+00 TM 20 58999 03/14/01 Ru-103 -2. 09E+00 1.21E+00 4. 61E+00 TM 20 58999 03/14/01 Ru-106 -6. 15E+00 1.06E+01 3. 88E+01 TM 20 58999 03/14/01 Sb-124 -1.88E+00 2.30E+00 9. 46E+00 TM 20 58999 03/14/01 Se-75 3. 03E+00 1 . 27E+00 4. 04E+00 TM 20 58999 03/14/01 Zn-65 -4.43E+00 2. 83E+00 1. 10E+01 TM 20 58999 03/14/01 Zr-95 -0.20E+00 2. 40E+00 8. 57E+00 TM 20 59445 04/11/01 Th-232 -9. 28E+00 4.48E+00 1. 78E+01 TM 20 59445 04/11/01 Ag-iIOM -0. 39E+00 1. 60E+00 5.88E+00 TM 20 59445 04/11/01 Ba-140 0. 00E+00 1. 62E+00 6. 13E+00 TM 20 59445 04/11/01 Be-7 6. 87E+00 9. 56E+00 3. 29E+01 TM 20 59445 04/11/01 Ce-141 3. 00E+00 2.14E+00 7. 07E+00 TM 20 59445 04/11/01 Ce-144 -1. 33E+01 8. 02E+00 2.88E+01 TM 20 59445 04/11/01 Co-57 1. 12E+00 1. 02E+00 3. 41E+00 TM 20 59445 04/11/01 Co-58 -0. 43E+00 1.24E+00 4.56E+00 TM 20 59445 04/11/01 Co-60 -2 . 04E+00 1. 18E+00 4 .87E+00 TM 20 59445 04/11/01 Cr-51 -3. 52E+00 1. 13E+01 4 . 01E+01 TM 20 59445 04/11/01 Cs-134 2. 15E+00 1 . 42E+00 4. 70E+00 TM 20 59445 04/11/01 Cs-137 -0. 25E+00 1. 36E+00 4.88E+00 TM 20 59445 04/11/01 Fe-59 -1. 85E+00 3. 87E+00 1. 44E+01 TM 20 59445 04/11/01 1-131 -7. 1OE-02 7. 92E-02 0. 70E+00 TM 20 59445 04/11/01 K-40 1. 41E+03 5. 28E+01 5.13E+01 TM 20 59445 04/11/01 Mn-54 1. 37E+00 1. 19E+00 4. 03E+00 TM 20 59445 04/11/01 Ru-103 -2. 82E+00 1. 22E+00 4. 78E+00 TM 20 59445 04/11 /01 Ru-106 4. 56E+00 1. 11E+01 3. 89E+01 TM 20 59445 04/11 /01 Sb-124 2. 39E+00 2. 69E+00 9. 41E+00 TM 20 59445 04/11 /01 Se-75 -0. 88E+00 1. 59E+00 5. 64E+00 TM 20 59445 04/11 /01 Zn-65 -6. 285+00 3. 23E+00 1. 25E+01 TM 20 59445 04/11 /01 Zr-95 -3. 1OE-02 1. 98E+00 7. 21E+00
- Concentration Greater than 3 Standard Deviations 109
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 20 59607 04/25/01 Th-232 -0. 45E+00 6. 42E+00 2. 38E+01 TM 20 59607 04/25/01 Ag-iIOM -0. 37E+00 2. 06E+00 7.87E+00 TM 20 59607 04/25/01 Ba-140 3. 68E+00 2. 44E+00 7. 92E+00 TM 20 59607 04/25/01 Be-7 -3. 52E+00 1. 49E+01 5. 46E+01 TM 20 59607 04/25/01 Ce-141 -1. 28E+00 2. 68E+00 9. 44E+00 TM 20 59607 04/25/01 Ce-144 -1. 19E+01 9. 12E+00 3. 31E+01 TM 20 59607 04/25/01 Co-57 -1. 77E+00 1. 14E+00 4 .17E+00 TM 20 59607 04/25/01 Co-58 -0. 41E+00 1. 53E+00 5. 8 9E+00 TM 20 59607 04/25/01 Co-60 -4 .46E+00 2. 02E+00 8.84E+00 TM 20 59607 04/25/01 Cr-51 2. 82E+01 1. 52E+01 4. 92E+01 TM 20 59607 04/25/01 Cs-134 0.28E+00 1.47E+00 5. 51E+00 TM 20 59607 04/25/01 Cs-137 -1. 88E+00 1. 71E+00 6. 68E+00 TM 20 59607 04/25/01 Fe-59 -5. 43E+00 6. 42E+00 2. 51E+01 TM 20 59607 04/25/01 1-131 2. 90E-02 0. 10E+00 0. 69E+00 TM 20 59607 04/25/01 K-40 1.4 1E+03 7.56E+01 8.57E+01
- TM 20 59607 04/25/01 Mn-54 0. 76E+00 1.59E+00 5. 70E+00 TM 20 59607 04/25/01 Ru-103 -0. 45E+00 1.71E+00 6. 34E+00 TM 20 59607 04/25/01 Ru-106 -1. 62E+01 1.47E+01 5. 75E+01 TM 20 59607 04/25/01 Sb-124 -3. 10E+00 3. 43E+00 1. 55E+01 TM 20 59607 04/25/01 Se-75 0. 88E+00 1. 99E+00 6. 90E+00 TM 20 59607 04/25/01 Zn-65 -4.47E+00 4.47E+00 1. 75E+01 TM 20 59607 04/25/01 Zr-95 0. 82E+00 2. 89E+00 1. 06E+01 TM 20 59892 05/09/01 Th-232 3. 54E+00 4. 62E+00 1. 59E+01 TM 20 59892 05/09/01 Ag-IIOM -1. 52E+00 1. 66E+00 6. 26E+00 TM 20 59892 05/09/01 Ba-140 1. 06E+00 1. 91E+00 6. 90E+00 TM 20 59892 05/09/01 Be-7 1. 18E+01 8. 77E+00 2. 93E+01 TM 20 59892 05/09/01 Ce-141 -3. 98E+00 1. 92E+00 7. 06E+00 TM 20 59892 05/09/01 Ce-144 -7. 33E-02 7.51E+00 2. 59E+01 TM 20 59892 05/09/01 Co-57 -0. 20E+00 0. 94E+00 3. 26E+00 TM 20 59892 05/09/01 Co-58 -0. 98E+00 1. 11E+00 4. 23E+00 TM 20 59892 05/09/01 Co-60 2.23E-02 1. 07E+00 4. OOE+00 TM 20 59892 05/09/01 Cr-51 1. 20E+01 1. 11E+01 3. 73E+01 TM 20 59892 05/09/01 Cs-134 -0. 88E+00 1. 14E+00 4. 32E+00 TM 20 59892 05/09/01 Cs-137 2. 01E+00 1. 16E+00 3. 77E+00 TM 20 59892 05/09/01 Fe-59 -1. 15E+00 3. 83E+00 1. 42E+01 TM 20 59892 05/09/01 1-131 5. 19E-02 0. 11E+00 0. 55E+00 TM 20 59892 05/09/01 K-40 1. 42E+03 5. 24E+01 5.44E+01
- TM 20 59892 05/09/01 Mn-54 -1. 25E+00 0. 93E+00 3. 69E+00 TM 20 59892 05/09/01 Ru-103 -0. 37E+00 1. 23E+00 4.45E+00 TM 20 59892 05/09/01 Ru-106 0. OOE+00 9. 52E+00 3. 43E+01 TM 20 59892 05/09/01 Sb-124 -1. 48E+00 2. 36E+00 9. 59E+00 TM 20 59892 05/09/01 Se-75 -1. 06E+00 1. 47E+00 5. 23E+00 TM 20 59892 05/09/01 Zn-65 -4.16E+00 3. 02E+00 1. 15E+01 TM 20 59892 05/09/01 Zr-95 -1. 98E+00 2. 04E+00 7. 75E+00
- Concentration Greater than 3 Standard Deviations 110
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 20 60118 05/23/01 Th-232 -4. 62E+00 4. 01E+00 1. 55E+01 TM 20 60118 05/23/01 Ag-IIOM 0. 79E+00 1. 61E+00 5. 66E+00 TM 20 60118 05/23/01 Ba-140 0. 63E+00 1. 54E+00 5. 69E+00 TM 20 60118 05/23/01 Be-7 -8. 96E+00 9. 80E+00 3. 64E+01 TM 20 60118 05/23/01 Ce-141 -4.16E+00 2. 06E+00 7. 51E+00 TM 20 60118 05/23/01 Ce-144 5. 42E+00 7. 61E+00 2. 57E+01 TM 20 60118 05/23/01 Co-57 -0. 54E+00 1. 03E+00 3. 61E+00 TM 20 60118 05/23/01 Co-58 -1. 31E+00 1. 19E+00 4. 56E+00 TM 20 60118 05/23/01 Co-60 1. 15E+00 1. 45E+00 5. 02E+00 TM 20 60118 05/23/01 Cr-51 -7. 24E+00 1.11E+01 3. 99E+01 TM 20 60118 05/23/01 Cs-134 0. 61E+00 1.36E+00 4.77E+00 TM 20 60118 05/23/01 Cs-137 0. 40E+00 1. 20E+00 4. 23E+00 TM 20 60118 05/23/01 Fe-59 0. 44E+00 3. 44E+00 1. 25E+01 TM 20 60118 05/23/01 1-131 0. 50E+00 0. 22E+00 0. 68E+00 TM 20 60118 05/23/01 K-40 1. 30E+03 5. 18E+01 6.11E+01
- TM 20 60118 05/23/01 Mn-54 -0. 55E+00 1. 15E+00 4. 26E+00 TM 20 60118 05/23/01 Ru-103 -0. 75E+00 1. 22E+00 4 .49E+00 TM 20 60118 05/23/01 Ru-106 2. 27E+01 1. 13E+01 3. 64E+01 TM 20 60118 05/23/01 Sb-124 -0. 8 9E+00 2. 02E+00 8. 32E+00 TM 20 60118 05/23/01 Se-75 -0. 11E+00 1.70E+00 5. 89E+00 TM 20 60118 05/23/01 Zn-65 -0. 75E+00 4. 17E+00 1.48E+01 TM 20 60118 05/23/01 Zr-95 -3. 55E+00 1.77E+00 7.29E+00 TM 20 60421 06/06/01 Th-232 7.28E+00 4.77E+00 1. 58E+01 TM 20 60421 06/06/01 Ag-11CM 1. 61E+00 1. 68E+00 5. 75E+00 TM 20 60421 06/06/01 Ba-140 -0. 43E+00 1.88E+00 7. 53E+00 TM 20 60421 06/06/01 Be-7 -6. 45E+00 9. 73E+00 3. 61E+01 TM 20 60421 06/06/01 Ce-141 -3. 02E+00 2. 37E+00 8.44E+00 TM 20 60421 06/06/01 Ce-144 0. 31E+00 8. 04E+00 2. 77E+01 TM 20 60421 06/06/01 Co-57 0. 86E+00 1. 08E+00 3. 64E+00 TM 20 60421 06/06/01 Co-58 -2. 31E+00 1. 24E+00 4. 94E+00 TM 20 60421 06/06/01 Co-60 0. 99E+00 1. 24E+00 4. 34E+00 TM 20 60421 06/06/01 Cr-51 -1. 05E+00 1. 30E+01 4. 57E+01 TM 20 60421 06/06/01 Cs-134 -2. O1E+00 1. 25E+00 4. 91E+00 TM 20 60421 06/06/01 Cs-137 1. 10E+00 1. 22E+00 4. 17E+00 TM 20 60421 06/06/01 Fe-59 -0. 69E+00 4 .17E+00 1. 53E+01 TM 20 60421 06/06/01 1-131 -8.70E-02 9.50E-02 0. 70E+00 TM 20 60421 06/06/01 K-40 1. 37E+03 5. 28E+01 5.80E+01
- TM 20 60421 06/06/01 Mn-54 0. 42E+00 1. 24E+00 4. 37E+00 TM 20 60421 06/06/01 Ru-103 -1. 39E+00 1. 43E+00 5. 29E+00 TM 20 60421 06/06/01 Ru-106 -1. 16E+01 1.04E+01 3. 94E+01 TM 20 60421 06/06/01 Sb-124 5.29E-02 2. 42E+00 9. 36E+00 TM 20 60421 06/06/01 Se-75 -0. 80E+00 1. 57E+00 5. 55E+00 TM 20 60421 06/06/01 Zn-65 -6. 36E+00 3. 26E+00 1. 27E+01 TM 20 60421 06/06/01 Zr-95 2. 61E+00 2. 06E+00 6. 91E+00
- Concentration Greater than 3 Standard Deviations Iil
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 20 60618 06/20/01 Th-232 1.24E+00 5. 19E+00 2. 43E+01 TM 20 60618 06/20/01 Ag-11GM -1.41E+00 1.75E+00 6. 55E+00 TM 20 60618 06/20/01 Ba-140 -1. 90E+00 1. 65E+00 7. 13E+00 TM 20 60618 06/20/01 Be-7 4. 16E+00 1. 08E+01 3.77E+01 TM 20 60618 06/20/01 Ce-141 0. 68E+00 2.28E+00 7.78E+00 TM 20 60618 06/20/01 Ce-144 4. 74E+00 8.73E+00 2. 96E+01 TM 20 60618 06/20/01 Co-57 1. 93E+00 1. 05E+00 3.44E+00 TM 20 60618 06/20/01 Co-58 1.55E+00 1.23E+00 4 .12E+00 TM 20 60618 06/20/01 Co-60 1.56E+00 1. 47E+00 5. 02E+00 TM 20 60618 06/20/01 Cr-51 -8.81E+00 1. 18E+01 4. 26E+01 TM 20 60618 06/20/01 Cs-134 1.36E+00 1. 31E+00 4.47E+00 TM 20 60618 06/20/01 Cs-137 -0. 79E+00 1. 35E+00 4. 92E+00 TM 20 60618 06/20/01 Fe-59 0. 90E+00 3. 45E+00 1. 25E+01 TM 20 60618 06/20/01 1-131 0. 16E+00 0. 17E+00 0. 82E+00 TM 20 60618 06/20/01 K-40 1. 43E+03 5. 40E+01 5.43E+01
- TM 20 60618 06/20/01 Mn-54 0. 82E+00 1. 17E+00 4. 06E+00 TM 20 60618 06/20/01 Ru-103 -0. 80E+00 1. 39E+00 5.06E+00 TM 20 60618 06/20/01 Ru-106 -7 14E+00 1. 08E+01 4.00E+01 TM 20 60618 06/20/01 Sb-124 4. 70E+00 2 .28E+00 6.85E+00 TM 20 60618 06/20/01 Se-75 0. 1lE+00 1. 67E+00 5. 78E+00 TM 20 60618 06/20/01 Zn-65 1. 81E+01 6. 96E+00 2.23E+01 TM 20 60618 06/20/01 Zr-95 -0. 44E+00 2. 18E+00 7. 97E+00 TM 20 60916 07/11/01 Th-232 1. 07E+00 4. 94E+00 1. 75E+01 TM 20 60916 07/11/01 Ag-lIOM 1. 78E+00 1. 69E+00 5. 74E+00 TM 20 60916 07/11/01 Ba-140 0. 62E+00 1. 59E+00 5.8 6E+00 TM 20 60916 07/11/01 Be-7 0 . OOE+00 8 78E+00 3.16E+01 TM 20 60916 07/11/01 Ce-141 -2. 33E+00 2 . 24E+00 7.89E+00 TM 20 60916 07/11/01 Ce-144 -1. 97E+01 8. 23E+00 3. 01E+01 TM 20 60916 07/11/01 Co-57 0. 70E+00 1. 01E+00 3.4 1E+00 TM 20 60916 07/11/01 Co-58 0. 72E+00 1. 35E+00 4.71E+00 TM 20 60916 07/11/01 Co-60 0. 39E+00 1. 14E+00 4.16E+00 TM 20 60916 07/11/01 Cr-51 -8 . 1lE+00 1. 16E+01 4. 16E+01 TM 20 60916 07/11/01 Cs-134 -1. 38E+00 1. 26E+00 4 .82E+00 TM 20 60916 07/11/01 Cs-137 -1. 64E+00 1. 43E+00 5. 31E+00 TM 20 60916 07/11/01 Fe-59 -1.30E+00 3. 54E+00 1. 32E+01 TM 20 60916 07/11/01 1-131 0. 13E+00 8 .74E-02 0. 35E+00 TM 20 60916 07/11/01 K-40 1. 26E+03 5. 08E+01 5.75E+01
- TM 20 60916 07/11/01 Mn-54 -1. 92E+00 1. 18E+00 4. 61E+00 TM 20 60916 07/11/01 Ru-103 -1. 37E+00 1. 27E+00 4.72E+00 TM 20 60916 07/11/01 Ru-106 1. 90E+00 1. 13E+01 3. 99E+01 TM 20 60916 07/11/01 Sb-124 0. 99E+00 2.47E+00 9.13E+00 TM 20 60916 07/11/01 Se-75 1. 1lE+00 1. 66E+00 5. 64E+00 TM 20 60916 07/11/01 Zn-65 -4.87E+00 6. 94E+00 2. 41E+01 TM 20 60916 07/11/01 Zr-95 -1. 32E+00 2. 10E+00 7.85E+00
- Concentration Greater than 3 Standard Deviations 112
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 20 61173 07 /25/01 Th-232 4.17E+00 4. 60E+00 1. 58E+01 TM 20 61173 07 /25/01 Ag-11OM 0.79E+00 1. 87E+00 6. 55E+00 TM 20 61173 07 /25/01 Ba-140 -2. 08E+00 1. 65E+00 6. 81E+00 TM 20 61173 07 /25/01 Be-7 2. 86E+01 1. 46E+01 4.75E+01 TM 20 61173 07 /25/01 Ce-141 -3. 59E+00 2. 16E+00 7. 74E+00 TM 20 61173 07 /25/01 Ce-144 -1. 58E+01 8. 24E+00 2. 98E+01 TM 20 61173 07 /25/01 Co-57 0. 48E+00 1. 05E+00 3. 56E+00 TM 20 61173 07 /25/01 Co-58 -2.44E+00 1.29E+00 5. 07E+00 TM 20 61173 07 /25/01 Co-60 -1. 95E+00 1. 30E+00 5. 22E+00 TM 20 61173 07 /25/01 Cr-51 -2. 12E+01 1. 16E+01 4. 32E+01 TM 20 61173 07 /25/01 Cs-134 -1. 08E+00 1. 38E+00 5. 15E+00 TM 20 61173 07 /25/01 Cs-137 0. 67E+00 1. 32E+00 4. 60E+00 TM 20 61173 07 /25/01 Fe-59 -1.4 8E+00 3. 24E+00 1. 23E+01 TM 20 61173 07 /25/01 1-131 0.27E+00 0. 18E+00 0. 65E+00 TM 20 61173 07 /25/01 K-40 1.34E+03 5. 19E+01 S.32E+01
- TM 20 61173 07 /25/01 Mn-54 1 . 64E+00 1. 23E+00 4. 09E+00 TM 20 61173 07 /25/01 Ru-103 -0. 37E+00 1. 23E+00 4.45E+00 TM 20 61173 07 /25/01 Ru-106 1. 24E+01 1. 08E+01 3. 63E+01 TM 20 61173 07 /25/01 Sb-124 -2. 54E+00 2. 32E+00 9. 77E+00 TM 20 61173 07 /25/01 Se-75 1. 87E+00 1. 69E+00 5. 64E+00 TM 20 61173 07 /25/01 Zn-65 2. 82E+00 6. 7 9E+00 2. 30E+01 TM 20 61173 07 /25/01 Zr-95 -1. 06E+00 2. 10E+00 7. 77E+00 TM 20 61372 08 /08/01 Th-232 -1. 42E+00 6. 35E+00 2. 38E+01 TM 20 61372 08 /08/01 Ag-IIOM 0. 37E+00 2. 29E+00 8.42E+00 TM 20 61372 08 /08/01 Ba-140 0. OOE+00 2. 68E+00 1. 05E+01 TM 20 61372 08 /08/01 Be-7 5. 09E+00 1. 39E+01 4 .92E+01 TM 20 61372 08 /08/01 Ce-141 -3. 40E+00 2. 52E+00 9. 12E+00 TM 20 61372 08 /08/01 Ce-144 -4. 75E+00 9. 14E+00 3. 23E+01 TM 20 61372 08 /08/01 Co-57 0. 71E+00 1. 15E+00 3. 91E+00 TM 20 61372 08 /08/01 Co-58 -2 82E+00 1. 54E+00 6. 54E+00 TM 20 61372 08 /08/01 Co-60 0. 68E+00 2. 37E+00 8. 61E+00 TM 20 61372 08 /08/01 Cr-51 -2. 92E+00 1. 52E+01 5. 43E+01 TM 20 61372 08 /08/01 Cs-134 -2. 98E+00 1. 92E+00 7. 76E+00 TM 20 61372 08 /08/01 Cs-137 1. 40E+00 1. 7 6E+00 6. 13E+00 TM 20 61372 08 /08/01 Fe-59 0. 83E+00 6. 08E+00 2. 24E+01 TM 20 61372 08 /08/01 1-131 -1. 80E-02 6. 18E-02 0. 48E+00 TM 20 61372 08 /08/01 K-40 1. 38E+03 7 42E+01 7.95E+01
- TM 20 61372 08 /08/01 Mn-54 0. OOE+00 1. 67E+00 6. 19E+00 TM 20 61372 08 /08/01 Ru-103 -1. 71E+00 1. 54E+00 6. 04E+00 TM 20 61372 08 /08/01 Ru-106 1. 45E+01 1. 43E+01 4. 90E+01 TM 20 61372 08 /08/01 Sb-124 4 . OOE+00 3. 16E+00 1. 08E+01 TM 20 61372 08 /08/01 Se-75 0. 35E+00 2. OOE+00 6. 99E+00 TM 20 61372 08 /08/01 Zn-65 -3 17E+00 4. 61E+00 1. 76E+01 TM 20 61372 08 /08/01 Zr-95 0. 85E+00 2. 87E+00 1. 04E+01
- Concentration Greater than 3 Standard Deviations 113
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 20 61552 08/22/01 Th-232 -3. 59E+00 4. 33E+00 1. 63E+01 TM 20 61552 08/22/01 Ag-IIOM -1. 20E+00 1. 67E+00 6. 27E+00 TM 20 61552 08/22/01 Ba-140 -1. 17E+00 1. 79E+00 7. 36E+00 TM 20 61552 08/22/01 Be-7 2. 10E+00 1 O1E+01 3. 56E+01 TM 20 61552 08/22/01 Ce-141 3. 19E+00 2. 37E+00 7. 87E+00 TM 20 61552 08/22/01 Ce-144 0. 15E+00 8 .20E+00 2. 82E+01 TM 20 61552 08/22/01 Co-57 -1. 40E+00 1. 06E+00 3. 77E+00 TM 20 61552 08/22/01 Co-58 -1. 81E+00 1. 23E+00 4 80E+00 TM 20 61552 08/22/01 Co-60 -0. 87E+00 1. 09E+00 4. 34E+00 TM 20 61552 08/22/01 Cr-51 -7. 01E+00 1. 33E+01 4 .72E+01 TM 20 61552 08/22/01 Cs-134 0. OOE+00 1. 31E+00 4 .72E+00 TM 20 61552 08/22/01 Cs-137 2. OOE+00 1. 30E+00 4 .30E+00 TM 20 61552 08/22/01 Fe-59 2. 63E+00 3. 30E+00 1. 16E+01 TM 20 61552 08/22/01 1-131 -9. 34E-02 6.40E-02 0. 61E+00 TM 20 61552 08/22/01 K-40 1. 35E+03 5. 25E+01 5. 80E+01
- TM 20 61552 08/22/01 Mn-54 -i .39E+00 1. 04E+00 4. 08E+00 TM 20 61552 08/22/01 Ru-103 -2. 95E+00 1.26E+00 4 99E+00 TM 20 61552 08/22 /01 Ru-106 -6. 14E+00 1. 19E+01 4.31E+01 TM 20 61552 08/22 /01 Sb-124 -0. 62E+00 2. 67E+00 1.04E+01 TM 20 61552 08/22 /01 Se-75 -2.83E+00 1. 74E+00 6.31E+00 TM 20 61552 08/22 /01 Zn-65 -6.71E+00 3. 26E+00 1.27E+01 TM 20 61552 08/22 /01 Zr-95 0.39E+00 2. 04E+00 7. 35E+00 TM 20 61801 09/05/01 Th-232 3. 14E+00 4. 66E+00 1. 61E+01 TM 20 61801 09/05/01 Ag-IIOM -4.73E+00 1. 85E+00 7.40E+00 TM 20 61801 09/05/01 Ba-140 0. 30E+00 1. 90E+00 6. 96E+00 TM 20 61801 09/05/01 Be-7 1. 47E+01 1.09E+01 3. 62E+01 TM 20 61801 09/05/01 Ce-141 -2. 68E+00 2. 45E+00 8. 60E+00 TM 20 61801 09/05/01 Ce-144 1. 39E+01 9.54E+00 3. 15E+01 TM 20 61801 09/05/01 Co-57 -0. 80E+00 1. 26E+00 4.37E+00 TM 20 61801 09/05/01 Co-58 -3. 02E+00 1. 53E+00 5. 86E+00 TM 20 61801 09/05/01 Co-60 0. 71E+00 1. 33E+00 4.73E+00 TM 20 61801 09/05/01 Cr-51 4 40E+00 1.40E+01 4.78E+01 TM 20 61801 09/05/01 Cs-134 -1. 08E+00 1.43E+00 5.31E+00 TM 20 61801 09/05/01 Cs-137 0. 56E+00 1. 50E+00 5.20E+00 TM 20 61801 09/05/01 Fe-59 -2 90E+00 3. 70E+00 1.41E+01 TM 20 61801 09/05/01 1-131 4. 51E-02 0. 12E+00 0.70E+00 TM 20 61801 09/05/01 K-40 1.24E+03 5. 07E+01 6.00E+01
- TM 20 61801 09/05/01 Mn-54 -1. 51E+00 1. 57E+00 5. 74E+00 TM 20 61801 09/05/01 Ru-103 -0. 49E+00 1. 29E+00 4. 64E+00 TM 20 61801 09/05/01 Ru-106 4 .75E+00 1. 10E+01 3. 84E+01 TM 20 61801 09/05/01 Sb-124 -2. 20E+00 2. 68E+00 1.08E+01 TM 20 61801 09/05/01 Se-75 0. 44E+00 1. 88E+00 6. 43E+00 TM 20 61801 09/05/01 Zn-65 4. 59E+00 7. 98E+00 2. 69E+01 TM 20 61801 09/05/01 Zr-95 -1. 06E+00 2. 10E+00 7. 77E+00
- Concentration Greater than 3 Standard Deviations 114
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 20 61986 09/19/01 Th-232 8.21E+00 8. 25E+00 2. 81E+01 TM 20 61986 09/19/01 Ag-IIOM 0.73E+00 2. 37E+00 8. 61E+00 TM 20 61986 09/19/01 Ba-140 3. 17E+00 2.7 6E+00 9. 51E+00 TM 20 61986 09/19/01 Be-7 -2. 21E+01 1.26E+01 5. 07E+01 TM 20 61986 09/19/01 Ce-141 -2. 59E+00 2. 58E+00 9. 25E+00 TM 20 61986 09/19/01 Ce-144 -3. 91E+00 9.82E+00 3. 44E+01 TM 20 61986 09/19/01 Co-57 -0. 13E+00 1. 25E+00 4. 33E+00 TM 20 61986 09/19/01 Co-58 -1. 73E+00 1. 36E+00 5. 73E+00 TM 20 61986 09/19/01 Co-60 -3. 59E+00 1. 85E+00 8. 15E+00 TM 20 61986 09/19/01 Cr-51 8. 78E+00 1.55E+01 5. 35E+01 TM 20 61986 09/19/01 Cs-134 2. 18E+00 1.56E+00 5. 19E+00 TM 20 61986 09/19/01 Cs-137 -0. 88E+00 1.73E+00 6. 55E+00 TM 20 61986 09/19/01 Fe-59 8. 51E+00 6. 50E+00 2. 18E+01 TM 20 61986 09/19/01 1-131 9. 15E-02 0. 10E+00 0.47E+00 TM 20 61986 09/19/01 K-40 1. 37E+03 7. 43E+01 8.31E+01
- TM 20 61986 09/19/01 Mn-54 -1. 51E+00 1.79E+00 6. 90E+00 TM 20 61986 09/19/01 Ru-103 -2. 14E+00 1. 72E+00 6. 65E+00 TM 20 61986 09/19/01 Ru-106 2. 09E+01 1.44E+01 4. 77E+01 TM 20 61986 09/19/01 Sb-124 -3. 00E+00 3. 61E+00 1.59E+01 TM 20 61986 09/19/01 Se-75 0. 52E+00 2.05E+00 7. 14E+00 TM 20 61986 09/19/01 Zn-65 -5. 71E+00 4.25E+00 1.70E+01 TM 20 61986 09/19/01 Zr-95 -1. 94E+00 2.57E+00 1. 03E+01 TM 20 62466 10/17/01 Th-232 -3. 80E+00 6. 15E+00 4.80E+01 TM 20 62466 10/17/01 Ag-IIOM 0 OOE+00 2.06E+00 7. 31E+00 TM 20 62466 10/17/01 Ba-140 3. 50E+00 2.73E+00 9. 15E+00 TM 20 62466 10/17/01 Be-7 -4. 93E+00 1. 19E+01 4. 24E+01 TM 20 62466 10/17/01 Ce-141 1 .71E+00 2.14E+00 7 19E+00 TM 20 62466 10/17/01 Ce-144 -3. 73E+00 7.38E+00 2. 57E+01 TM 20 62466 10/17/01 Co-57 0. 40E+00 0. 96E+00 3. 28E+00 TM 20 62466 10/17/01 Co-58 0. 22E+00 1. 39E+00 4 .92E+00 TM 20 62466 10/17/01 Co-60 1. 23E+00 1. 68E+00 5. 80E+00 TM 20 62466 10/17/01 Cr-51 2. 88E+01 1.35E+01 4. 35E+01 TM 20 62466 10/17/01 Cs-134 -2. 11E+00 1. 38E+00 5. 33E+00 TM 20 62466 10/17/01 Cs-137 2 .40E+00 1.4 6E+00 4. 78E+00 TM 20 62466 10/17/01 Fe-59 1. 77E+00 5. 03E+00 1. 77E+01 TM 20 62466 10/17/01 1-131 3. 17E-02 7. 64E-02 0. 44E+00 TM 20 62466 10/17/01 K-40 1. 34E+03 5.50E+01 7. 34E+01
- TM 20 62466 10/17/01 Mn-54 -2. 00E+00 1.26E+00 4 88E+00 TM 20 62466 10/17/01 Ru-103 -1. 95E+00 1. 62E+00 5 92E+00 TM 20 62466 10/17 /01 Ru-106 4 . 10E+00 1.20E+01 4.19E+01 TM 20 62466 10/17 /01 Sb-124 -3. 25E+00 3. 06E+00 1. 25E+01 TM 20 62466 10/17 /01 Se-75 -1. 47E+00 1.4 6E+00 5. 25E+00 TM 20 62466 10/17 /01 Zn-65 4. 79E+00 5. 16E+00 1. 68E+01 TM 20 62466 10/17 /01 Zr-95 -1. 07E+00 2.43E+00 8. 87E+00
- Concentration Greater than 3 Standard Deviations 115
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MILK TM 20 62939 11/14/01 Th-232 5.79E+00 5. 60E+00 1. 89E+01 TM 20 62939 11/14/01 Ag-IIOM 1. 38E+00 1. 80E+00 6. 20E+00 TM 20 62939 11/14/01 Ba-140 1.25E+00 1.40E+00 4. 96E+00 TM 20 62939 11/14/01 Be-7 2. 59E+01 1. 01E+01 3. 16E+01 TM 20 62939 11/14/01 Ce-141 -4.16E+00 2. 22E+00 8. OOE+00 TM 20 62939 11/14/01 Ce-144 1. 30E+01 8. 01E+00 2. 63E+01 TM 20 62939 11/14/01 Co-57 -1. 99E+00 1. 02E+00 3. 71E+00 TM 20 62939 11/14/01 Co-58 -2. 18E+00 1. 13E+00 4. 55E+00 TM 20 62939 11/14/01 Co-60 -2.41E+00 1. 15E+00 4 .88E+00 TM 20 62939 11/14/01 Cr-51 1. 45E+01 1. 18E+01 3. 93E+01 TM 20 62939 11/14/01 Cs-134 -0. 4 6E+00 1. 16E+00 4. 33E+00 TM 20 62939 11/14/01 Cs-137 1.21E+00 1. 35E+00 4. 60E+00 TM 20 62939 11/14/01 Fe-59 -6. 62E+00 3. 74E+00 1. 49E+01 TM 20 62939 11/14/01 1-131 0. 16E+00 0. 13E+00 0. 53E+00 TM 20 62939 11/14/01 K-40 1. 4 6E+03 5. 36E+01 5.01E+01
- TM 20 62939 11/14/01 Mn-54 1. 78E+00 1. 16E+00 3. 81E+00 TM 20 62939 11/14/01 Ru-103 -1. 62E+00 1. 23E+00 4. 64E+00 TM 20 62939 11/14/01 Ru-106 5. 90E+00 1. 11E+01 3. 84E+01 TM 20 62939 11/14/01 Sb-124 1.28E+00 2. 92E+00 1. 06E+01 TM 20 62939 11/14/01 Se-75 1.22E+00 1. 52E+00 5. 15E+00 TM 20 62939 11/14/01 Zn-65 -5. 70E+00 6.20E+00 2. 18E+01 TM 20 62939 11/14/01 Zr-95 -1.29E+00 1. 93E+00 7. 29E+00 TM 20 63305 12/12/01 Th-232 -5. 10E+00 4.50E+00 1. 71E+01 TM 20 63305 12/12/01 Ag-IlOM 1. 77E+00 1.54E+00 5. 21E+00 TM 20 63305 12/12/01 Ba-140 0. 29E+00 1. 64E+00 6. 11E+00 TM 20 63305 12/12/01 Be-7 9. 81E+00 9.30E+00 3. 15E+01 TM 20 63305 12/12/01 Ce-141 -1. 62E+00 2.04E+00 7 .18E+00 TM 20 63305 12/12/01 Ce-144 1. 45E+00 8. 35E+00 2. 86E+01 TM 20 63305 12/12/01 Co-57 1. 44E+00 1.01E+00 3. 33E+00 TM 20 63305 12/12/01 Co-58 -1. 87E+00 1.21E+00 4.72E+00 TM 20 63305 12/12/01 Co-60 -0. 30E+00 1. 17E+00 4.41E+00 TM 20 63305 12/12/01 Cr-51 1. 32E+01 1.08E+01 3. 61E+01 TM 20 63305 12/12/01 Cs-134 2. 30E+00 1. 20E+00 3. 84E+00 TM 20 63305 12/12/01 Cs-137 -0. 92E+00 1. 22E+00 4. 54E+00 TM 20 63305 12/12/01 Fe-59 3. 56E+00 3. 37E+00 1. 15E+01 TM 20 63305 12/12/01 1-131 0. 17E+00 0. 14E+00 0. 56E+00 TM 20 63305 12/12/01 K-40 1. 31E+03 5. 12E+01 5.25E+01
- TM 20 63305 12/12/01 Mn-54 0. OOE+00 1. 27E+00 4. 55E+00 TM 20 63305 12/12/01 Ru-103 -2. 08E+00 1. 22E+00 4. 67E+00 TM 20 63305 12/12/01 Ru- 106 1. 01E+01 9.67E+00 3.29E+01 TM 20 63305 12/12/01 Sb-124 -1. 07E+00 2.4 6E+00 9. 76E+00 TM 20 63305 12/12/01 Se-75 2. 20E+00 1. 66E+00 5. 51E+00 TM 20 63305 12/12/01 Zn-65 -6. 15E+00 3. 12E+00 1 . 22E+01 TM 20 63305 12/12/01 Zr-95 1.09E+00 1. 73E+00 6. 10E+00
- Concentration Greater than 3 Standard Deviations 116
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) GROUND WATER WG 01 59076 03/20/01 Th-232 -4. 29E+00 3. 17E+00 1. 22E+01 WG 01 59076 03/20/01 Ag-IIGM -2. 03E+00 1. 16E+00 4. 59E+00 WG 01 59076 03/20/01 Ba-140 0. OOE+00 1. 17E+00 4. 51E+00 WG 01 59076 03/20/01 Be-7 -5. 88E+00 7. 63E+00 2.80E+01 WG 01 59076 03/20/01 Ce-141 1.43E+00 1.75E+00 5. 87E+00 WG 01 59076 03/20/01 Ce-144 2. 96E+00 6. 48E+00 2. 20E+01 WG 01 59076 03/20/01 Co-57 -1. 13E+00 0. 83E+00 2. 94E+00 WG 01 59076 03/20/01 Co-58 -0. 11E+00 0. 98E+00 3. 55E+00 WG 01 59076 03/20/01 Co-60 0. 27E+00 0. 99E+00 3. 56E+00 WG 01 59076 03/20/01 Cr-51 -3. 37E+00 8. 61E+00 3. 06E+01 WG 01 59076 03/20/01 Cs-134 0. 34E+00 0. 89E+00 3. 17E+00 WG 01 59076 03/20/01 Cs-137 -0. 21E+00 0. 94E+00 3. 40E+00 WG 01 59076 03/20/01 Fe-59 -2. 18E+00 2. 36E+00 9. 25E+00 WG 01 59076 03/20/01 GR-B 5. 54E+00 1. 02E+00 3. 13E+00
- WG 01 59076 03/20/01 H-3 5.36E+02 3. 69E+02 1. 22E+03 WG 01 59076 03/20/01 1-131 -2. 13E+00 2. 08E+00 7. 56E+00 WG 01 59076 03/20/01 K-40 1.38E+01 1. 06E+01 3. 56E+01 WG 01 59076 03/20/01 Mn-54 -I. 00E+00 0. 88E+00 3. 34E+00 WG 01 59076 03/20/01 Ru-103 -i. 85E+00 0. 98E+00 3. 75E+00 WG 01 59076 03/20/01 Ru-106 1. 10E+01 7 77E+00 2. 58E+01 WG 01 59076 03/20/01 Sb-124 -0. 1IE+00 1. 99E+00 7. 55E+00 WG 01 59076 03/20/01 Se-75 0. 89E+00 1. 29E+00 4. 36E+00 WG 01 59076 03/20/01 Zn-65 -5. 39E+00 4. 98E+00 1.75E+01 WG 01 59076 03/20/01 Zr-95 0. 44E+00 1. 43E+00 5. 12E+00 WG 01 60450 06/11/01 Th-232 2. 59E+00 3. 30E+00 1. 15E+01 WG 01 60450 06/11/01 Ag-IIOM 1. 73E+00 1. 47E+00 4. 98E+00 WG 01 60450 06/11/01 Ba-140 -0. 64E+00 1. 91E+00 7. 30E+00 WG 01 60450 06/11/01 Be-7 -4 83E+00 9. 41E+00 3 44E+01 WG 01 60450 06/11/01 Ce-141 -0. 82E+00 2. 06E+00 7 . 18E+00 WG 01 60450 06/11/01 Ce-144 0. 67E+00 7. 56E+00 2. 60E+01 WG 01 60450 06/11/01 Co-57 -0. 98E+00 1. 01E+00 3. 55E+00 WG 01 60450 06/11/01 Co-58 -1. 48E+00 1. 1IE+00 4 .33E+00 WG 01 60450 06/11/01 Co-60 1. 33E+00 1. 12E+00 3. 81E+00 WG 01 60450 06/11/01 Cr-51 1. 85E+01 1. 12E+01 3. 67E+01 WG 01 60450 06/11/01 Cs-134 1. 97E+00 0. 97E+00 3. 06E+00 WG 01 60450 06/11/01 Cs-137 -1. 80E+00 1. 23E+00 4. 72E+00 WG 01 60450 06/11/01 Fe-59 0. 95E+00 3. 02E+00 1. 10E+01 WG 01 60450 06/11/01 GR-B 7. 52E+00 0. 96E+00 2. 83E+00
- WG 01 60450 06/11/01 H-3 1. 07E+02 3. 67E+02 1. 26E+03 WG 01 60450 06/11/01 1-131 1. 28E+00 2. 31E+00 7. 99E+00 WG 01 60450 06/11/01 K-40 -7. 99E+00 1. 51E+01 5. 61E+01 WG 01 60450 06/11/01 Mn-54 0. 23E+00 0. 82E+00 2. 99E+00 WG 01 60450 06/11/01 Ru-103 0 . 73E+00 1. 12E+00 3. 86E+00 WG 01 60450 06/11/01 Ru-106 -5. 89E+00 9. 59E+00 3. 56E+01 WG 01 60450 06/11/01 Sb-124 -0. 97E+00 2. 66E+00 1. 04E+01
- Concentration Greater than 3 Standard Deviations 117
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) WG 01 60450 06/11/01 Se-75 0.21E+00 1.53E+00 5. 29E+00 WG 01 60450 06/11/01 Zn-65 1. 19E+01 5. 93E+00 1. 93E+01 WG 01 60450 06/11/01 Zr-95 2. 05E+00 1. 78E+00 6.02E+00
- Concentration Greater than 3 Standard Deviations 118
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) GROUND WATER WG 01 61942 09/10/01 Th-232 9.55E+00 5.76E+00 1.88E+01 WG 01 61942 09/10/01 Ag-lIOM -0.78E+00 2.06E+00 7.70E+00 WG 01 61942 09/10/01 Ba-140 0.83E+00 2.81E+00 1.04E+01 WG 01 61942 09/10/01 Be-7 -1.23E+01 1.13E+01 4.34E+01 WG 01 61942 09/10/01 Ce-141 -2.54E+00 2.95E+00 1.03E+01 WG 01 61942 09/10/01 Ce-144 9.15E+00 1.01E+01 3.39E+01 WG 01 61942 09/10/01 Co-57 0.63E+00 1.31E+00 4.43E+00 WG 01 61942 09/10/01 Co-58 -1.80E+00 1.45E+00 5.75E+00 WG 01 61942 09/10/01 Co-60 -2.10E+00 1.79E+00 7.15E+00 WG 01 61942 09/10/01 Cr-51 -2.33E+01 1.61E+01 5.91E+01 WG 01 61942 09/10/01 Cs-134 -0.23E+00 1.39E+00 5.22E+00 WG 01 61942 09/10/01 Cs-137 -1.18E+00 1.77E+00 6.51E+00 WG 01 61942 09/10/01 Fe-59 -1.19E+00 3.98E+00 1.54E+01 WG 01 61942 09/10/01 GR-B 7.23E+00 1.54E+00 4.80E+00
- WG 01 61942 09/10/01 H-3 0.OOE+00 3.82E+02 1.30E+03 WG 01 61942 09/10/01 1-131 -2.56E+00 3.33E+00 1.22E+01 WG 01 61942 09/10/01 K-40 -2.03E+01 1.91E+01 7.50E+01 WG 01 61942 09/10/01 Mn-54 -1.07E+00 1.24E+00 4.87E+00 WG 01 61942 09/10/01 Ru-103 1.21E+00 1.48E+00 5.11E+00 WG 01 61942 09/10/01 Ru-106 1.39E+01 1.34E+01 4.54E+01 WG 01 61942 09/10/01 Sb-124 1.53E+00 3.90E+00 1.44E+01 WG 01 61942 09/10/01 Se-75 0.28E+00 2.06E+00 7.11E+00 WG 01 61942 09/10/01 Zn-65 8.77E-02 8.24E+00 2.84E+01 WG 01 61942 09/10/01 Zr-95 -0.81E+00 2.09E+00 8.06E+00 WG 01 63211 12/05/01 Th-232 -1.62E+00 5.70E+00 2.02E+01 WG 01 63211 12/05/01 Ag-IIOM -2.48E+00 1.90E+00 7.11E+00 WG 01 63211 12/05/01 Ba-140 -3.54E+00 2.30E+00 9.21E+00 WG 01 63211 12/05/01 Be-7 1.33E+01 1.07E+01 3.57E+01 WG 01 63211 12/05/01 Ce-141 0.25E+00 1.80E+00 6.09E+00 WG 01 63211 12/05/01 Ce-144 4.12E+00 6.52E+00 2.19E+01 WG 01 63211 12/05/01 Co-57 -0.77E+00 0.83E+00 2.86E+00 WG 01 63211 12/05/01 Co-58 -4.78E-02 1.27E+00 4.54E+00 WG 01 63211 12/05/01 Co-60 0.27E+00 1.70E+00 6.02E+00 WG 01 63211 12/05/01 Cr-51 -9.18E+00 1.22E+01 4.28E+01 WG 01 63211 12/05/01 Cs-134 1.36E+00 1.43E+00 4.87E+00 WG 01 63211 12/05/01 Cs-137 -1.79E+00 1.38E+00 5.09E+00 WG 01 63211 12/05/01 Fe-59 -2.29E+00 3.92E+00 1.46E+01 WG 01 63211 12/05/01 GR-B 6.63E+00 0.52E+00 1.21E+00
- WG 01 63211 12/05/01 H-3 8.70E+00 1.22E+02 3.87E+02 WG 01 63211 12/05/01 1-131 0.32E+00 2.68E+00 9.21E+00 WG 01 63211 12/05/01 K-40 -3.30E+01 2.17E+01 8.09E+01 WG 01 63211 12/05/01 Mn-54 2.79E+00 1.38E+00 4.44E+00 WG 01 63211 12/05/01 Ru-103 -1.98E+00 1.40E+00 5.08E+00 WG 01 63211 12/05/01 Ru-106 -3.35E+01 1.28E+01 4.85E+01 WG 01 63211 12/05/01 Sb-124 1.53E+00 3.63E+00 1.30E+01
- Concentration Greater than 3 Standard Deviations 119
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) WG 01 63211 12/05/01 Se-75 -4 .14E+00 1. 54E+00 5. 61E+00 WG 01 63211 12/05/01 Zn-65 -7.45E+00 6. 99E+00 2.44E+01 WG 01 63211 12/05/01 Zr-95 3. 29E+00 2. 13E+00 7 . 01E+00
- Concentration Greater than 3 Standard Deviations 120
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) GROUND WATER WG 13 59075 03/20/01 Th-232 -2. 64E+00 4 41E+00 1. 64E+01 WG 13 59075 03/20/01 Ag-11OM 1. 98E+00 1. 37E+00 4 55E+00 WG 13 59075 03/20/01 Ba-140 -1. 89E+00 1. 74E+00 7. 27E+00 WG 13 59075 03/20/01 Be-7 1. 94E+00 1. 04E+01 3. 64E+01 WG 13 59075 03/20/01 Ce-141 -5. 38E+00 1. 99E+00 7. 30E+00 WG 13 59075 03/20/01 Ce-144 0. 20E+00 7. 29E+00 2. 50E+01 WG 13 59075 03/20/01 Co-57 -6. 71E-02 0. 95E+00 3. 25E+00 WG 13 59075 03/20/01 Co-58 -0. 11E+00 0. 96E+00 3. 59E+00 WG 13 59075 03/20/ 01 Co-60 1. 11E+00 1. 12E+00 3. 87E+00 WG 13 59075 03/20/01 Cr-51 0. OOE+00 1. 18E+01 4 11E+01 WG 13 59075 03/20/01 Cs-134 -0. 29E+00 1. 08E+00 4. 04E+00 WG 13 59075 03/20/01 Cs-137 0. 0OE+00 1. 28E+00 4.58E+00 WG 13 59075 03/20/01 Fe-59 -1. 04E+00 3. 13E+00 1. 20E+01 WG 13 59075 03/20/01 GR-B 5 .42E+00 1. 03E+00 3. 17E+00
- WG 13 59075 03/20/ 01 H-3 5. 40E+02 3. 71E+02 1. 23E+03 WG 13 59075 03/20/ 01 1-131 1. 69E+00 2 49E+00 8. 52E+00 WG 13 59075 03/20/ 01 K-40 -1. 22E+01 1. 53E+01 5. 83E+01 WG 13 59075 03/20/ 01 Mn-54 0. 16E+00 0. 91E+00 3. 33E+00 WG 13 59075 03/20/01 Ru-103 -0. 61E+00 0. 97E+00 3 66E+00 WG 13 59075 03/20/01 Ru-106 2. 64E+00 9. 67E+00 3 44E+01 WG 13 59075 03/20/01 Sb-124 -1. 63E+00 2 . 37E+00 9. 86E+00 WG 13 59075 03/20/01 Se-75 2. 24E+00 1. 45E+00 4. 78E+00 WG 13 59075 03/20/01 Zn-65 7. 71E+00 5. 45E+00 1.80E+01 WG 13 59075 03/20/01 Zr-95 0. 73E+00 1. 87E+00 6. 68E+00 WG 13 60451 06/11/01 Th-232 -2. 58E+00 4. 21E+00 1. 59E+01 WG 13 60451 06/11/01 Ag-11CM 0.21E+00 1. 54E+00 5. 58E+00 WG 13 60451 06/11/01 Ba-140 3. 80E+00 1. 98E+00 6.26E+00 WG 13 60451 06/11/01 Be-7 -3. 15E+00 9. 91E+00 3. 60E+01 WG 13 60451 06/11/ 01 Ce-141 -1.33E+00 2 .20E+00 7. 72E+00 WG 13 60451 06/11/01 Ce-144 9. 90E+00 7. 93E+00 2. 64E+01 WG 13 60451 06/11/01 Co-57 -0. 62E+00 1 01E+00 3. 54E+00 WG 13 60451 06/11/ 01 Co-58 -1. 82E+00 1. OE+00 4 .12E+00 WG 13 60451 06/11/01 Co-60 1. 24E+00 1. 19E+00 4 11E+00 WG 13 60451 06/11/01 Cr-51 1. 25E+01 1. 08E+01 3. 63E+01 WG 13 60451 06/11/01 Cs-134 -0. 12E+00 1. 04E+00 3. 90E+00 WG 13 60451 06/11/01 Cs-137 -1. 15E+00 1. 18E+00 4 .49E+00 WG 13 60451 06/11/01 Fe-59 -4. 83E+00 3. 09E+00 1. 28E+01 WG 13 60451 06/11/01 GR-B 3. 60E+00 0. 92E+00 2. 88E+00
- WG 13 60451 06/11/01 H-3 -1. 06E+02 3. 57E+02 1. 25E+03 WG 13 60451 06/11/01 1-131 0. 94E+00 2.58E+00 9. 0OE+00 WG 13 60451 06/11/01 K-40 -1. 81E+01 1. 17E+01 4 83E+01 WG 13 60451 06/11/01 Mn-54 -1. 30E+00 1. 18E+00 4. 52E+00 WG 13 60451 06/11/01 Ru-103 -0. 26E+00 1. 08E+00 3. 95E+00 WG 13 60451 06/11/01 Ru-106 1. 26E+01 8.33E+00 2. 75E+01 WG 13 60451 06/11/01 Sb-124 3. 15E+00 2 . 57E+00 8 74E+00 WG 13 60451 06/11/01 Se-75 -0. 12E+00 1.57E+00 5. 49E+00
- Concentration Greater than 3 Standard Deviations 121
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) WG 13 60451 06/11/01 Zn-65 -4. 36E+00 5.97E+00 2.10E+01 WG 13 60451 06/11/01 Zr-95 2. 36E+00 1.81E+00 6.08E+00
- Concentration Greater than 3 Standard Deviations 122
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) GROUND WATER WG 13 61943 09/10/01 Th-232 2. 22E+00 6. 57E+00 2. 37E+01 WG 13 61943 09/10/01 Ag-IIOM -1. 13E+00 2. 04E+00 8. 06E+00 WG 13 61943 09/10/01 Ba-140 -0.71E+00 2. 94E+00 1. 19E+01 WG 13 61943 09/10/01 Be-7 -3. 57E+00 1. 18E+01 4.47E+01 WG 13 61943 09/10/01 Ce-141 -6. 30E+00 2.79E+00 1.04E+01 WG 13 61943 09/10/01 Ce-144 1.76E+01 9. 52E+00 3. 10E+01 WG 13 61943 09/10/01 Co-57 0. 85E+00 1. 29E+00 4. 37E+00 WG 13 61943 09/10/01 Co-58 -0. 69E+00 1. 53E+00 5. 99E+00 WG 13 61943 09/10/01 Co-60 -1 . 77E+00 2. OOE+00 8. 12E+00 WG 13 61943 09/10/01 Cr-51 3. 62E+01 1. 64E+01 5. 22E+01 WG 13 61943 09/10/01 Cs-134 1. 19E+00 1. 63E+00 5. 80E+00 WG 13 61943 09/10/01 Cs-137 -I .40E+00 1. 46E+00 5. 83E+00 WG 13 61943 09/10/01 Fe-59 -2. 37E+00 4 .87E+00 1. 95E+01 WG 13 61943 09/10/01 GR-B 1 .58E+00 1. 4 6E+00 4. 78E+00 WG 13 61943 09/10/01 H-3 1. 50E+02 3. 85E+02 1. 30E+03 WG 13 61943 09/10/01 1-131 1. 65E+00 3. 51E+00 1. 23E+01 WG 13 61943 09/10/01 K-40 1. 72E+01 2. 23E+01 7. 84E+01 WG 13 61943 09/10/01 Mn-54 0. 26E+00 1. 67E+00 6.12E+00 WG 13 61943 09/10/01 Ru-103 0. 45E+00 1. 85E+00 6.59E+00 WG 13 61943 09/10/01 Ru-106 -i .32E+01 1. 38E+01 5. 43E+01 WG 13 61943 09/10/01 Sb-124 -6. 28E+00 4 44E+00 1. 97E+01 WG 13 61943 09/10/01 Se-75 3. 26E+00 1. 88E+00 6. 14E+00 WG 13 61943 09/10/01 Zn-65 -i 05E+01 3. 70E+00 1. 67E+01 WG 13 61943 09/10/01 Zr-95 -3. 16E+00 2. 37E+00 1. 01E+01 WG 13 63212 12/05/01 Th-232 -6. 33E+00 3. 62E+00 1. 48E+01 WG 13 63212 12/05/01 Ag-IIOM -2. 51E+00 1. 48E+00 5. 98E+00 WG 13 63212 12/05/01 Ba-140 -0. 77E+00 1. 81E+00 7. 28E+00 WG 13 63212 12/05/01 Be-7 2. 16E+00 9. 16E+00 3. 26E+01 WG 13 63212 12/05/01 Ce-141 -1. 91E+00 1. 94E+00 6. 95E+00 WG 13 63212 12/05/01 Ce-144 6. 26E+00 7. 35E+00 2 48E+01 WG 13 63212 12/05/01 Co-57 0. 67E+00 0. 94E+00 3. 19E+00 WG 13 63212 12/05/01 Co-58 1. 56E+00 1. 10E+00 3. 65E+00 WG 13 63212 12/05/01 Co-60 -0. 46E+00 0. 96E+00 3. 82E+00 WG 13 63212 12/05/01 Cr-51 1. 01E+00 1. 15E+01 4. 04E+01 WG 13 63212 12/05/01 Cs-134 1. 49E+00 1. 01E+00 3. 32E+00 WG 13 63212 12/05/01 Cs-137 -0. 73E+00 1. 21E+00 4 .49E+00 WG 13 63212 12/05/01 Fe-59 4. 65E+00 3. 04E+00 9. 99E+00 WG 13 63212 12/05/01 GR-B 3. 30E+00 0. 80E+00 2. 38E+00
- WG 13 63212 12/05/01 H-3 -i . 64E+02 1. 20E+02 3. 8 9E+02 WG 13 63212 12/05/01 1-131 -0. 28E+00 2. 62E+00 9. 41E+00 WG 13 63212 12/05/01 K-40 -0. 42E+00 1. 33E+01 4. 91E+01 WG 13 63212 12/05/01 Mn-54 1. 01E+00 1. 03E+00 3. 55E+00 WG 13 63212 12/05/01 Ru-103 -0. 82E+00 1. 37E+00 5. 02E+00 WG 13 63212 12/05/01 Ru-106 -i .22E+01 8. 75E+00 3. 47E+01 WG 13 63212 12/05/01 Sb-124 -I. 61E+00 2. 08E+00 8. 96E+00
- Concentration Greater than 3 Standard Deviations 123
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) WG 13 63212 12/05/01 Se-75 1. 05E+00 1. 4 9E+00 5. 08E+00 WG 13 63212 12/05/01 Zn-65 -1. 31E+00 5. 51E+00 1. 92E+01 WG 13 63212 12/05/01 Zr-95 1. 05E+00 1. 75E+00 6. 22E+00
- Concentration Greater than 3 Standard Deviations 124
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 01 58217 01/22/01 Th-232 -0. 49E+00 4.33E+00 1.58E+01 WS 01 58217 01/22/01 Ag-lIOM -0. 80E+00 1. 39E+00 5.29E+00 WS 01 58217 01/22/01 Ba-140 0. 94E+00 1. 75E+00 6.31E+00 WS 01 58217 01/22/01 Be-7 1. 41E+01 8 .42E+00 2.75E+01 WS 01 58217 01/22/01 Ce-141 -0. 61E+00 2. 09E+00 7.26E+00 WS 01 58217 01/22/01 Ce-144 -4. 25E+00 7 .80E+00 2.73E+01 WS 01 58217 01/22/01 Co-57 -1. 61E+00 0. 98E+00 3.55E+00 WS 01 58217 01/22/01 Co-58 -1. 47E+00 1. 12E+00 4.38E+00 WS 01 58217 01/22/01 Co-60 2. 30E+00 1. 08E+00 3.31E+00 WS 01 58217 01/22/01 Cr-51 1. 82E+00 1. 17E+01 4.06E+01 WS 01 58217 01/22/01 Cs-134 -1. 87E+00 1. 06E+00 4. 33E+00 WS 01 58217 01/22/01 Cs-137 0. 16E+00 1. 18E+00 4.22E+00 WS 01 58217 01/22/01 Fe-59 4 . 05E+00 2. 70E+00 8. 90E+00 WS 01 58217 01/22/01 1-131 -2. 49E+00 2. 33E+00 8. 59E+00 WS 01 58217 01/22/01 K-40 3. 14E+02 2. 85E+01 5.44E+01
- WS 01 58217 01/22/01 Mn-54 0. 70E+00 1. 17E+00 4. 10E+00 WS 01 58217 01/22/01 Ru-103 0. 88E+00 1. 19E+00 4. 10E+00 WS 01 58217 01/22/01 Ru-106 -2. 70E+01 9. 88E+00 4. 05E+01 WS 01 58217 01/22/01 Sb-124 -1. 65E+00 2. 58E+00 1. 04E+01 Ws 01 58217 01/22/01 Se-75 2.4 6E+00 1. 57E+00 5.16E+00 WS 01 58217 01/22/01 Zn-65 2. 42E+00 5. 92E+00 2. 02E+01 WS 01 58217 01/22/01 Zr-95 -0. 60E+00 1.71E+00 6. 45E+00 WS 01 58772 02/20/01 Th-232 -3.12E+00 4.17E+00 1.58E+01 WS 01 58772 02/20/01 Ag-11CM -1. 22E+00 1. 63E+00 6. 16E+00 WS 01 58772 02/20/01 Ba-140 2. 64E+00 2. 78E+00 9. 63E+00 WS 01 58772 02/20/01 Be-7 5. 45E+00 1.06E+01 3. 70E+01 WS 01 58772 02/20/01 Ce-141 2. 06E+00 2. 05E+00 6. 91E+00 WS 01 58772 02/20/01 Ce-144 -5. 57E+00 9. 00E+00 3. 14E+01 WS 01 58772 02/20/01 Co-57 -0. 64E+00 1. 16E+00 4. 03E+00 WS 01 58772 02/20/01 Co-58 -0. 62E+00 1. 34E+00 4. 96E+00 WS 01 58772 02/20/01 Co-60 2. 72E+00 1. 17E+00 3. 55E+00 WS 01 58772 02/20/01 Cr-51 6. 39E+00 1. 51E+01 5. 17E+01 WS 01 58772 02/20/01 Cs-134 1. 88E+00 1. 35E+00 4. 48E+00 WS 01 58772 02/20/01 Cs-137 -3. 95E+00 1. 18E+00 4. 96E+00 WS 01 58772 02/20/01 Fe-59 4. 25E+00 3. 42E+00 1. 16E+01 WS 01 58772 02/20/01 1-131 -2.4 9E+00 4. 62E+00 1. 65E+01 WS 01 58772 02/20/01 K-40 3. 30E+02 2. 92E+01 5.55E+01
- WS 01 58772 02/20/01 Mn-54 -2. 12E+00 1. 27E+00 4. 93E+00 WS 01 58772 02/20/01 Ru-103 0. 42E+00 1. 50E+00 5. 24E+00 WS 01 58772 02/20/01 Ru-106 1. 15E+01 1. 10E+01 3. 73E+01 WS 01 58772 02/20/01 Sb-124 -4. 29E+00 3. 32E+00 1.35E+01 WS 01 58772 02/20/01 Se-75 -1. 28E+00 1. 88E+00 6. 61E+00 WS 01 58772 02/20/01 Zn-65 6. 81E+00 6.27E+00 2.09E+01 WS 01 58772 02/20/01 Zr-95 -0. 10E+00 1. 87E+00 6. 90E+00
- Concentration Greater than 3 Standard Deviations 125
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 01 59073 03/19/01 Th-232 8. 67E+00 5.45E+00 1.79E+01 WS 01 59073 03/19/01 Ag-IIOM 0. OOE+00 1.56E+00 5.87E+00 WS 01 59073 03/19/01 Ba-140 -1. 94E+00 1. 94E+00 8.43E+00 WS 01 59073 03/19/01 Be-7 1. 25E+00 9.12E+00 3. 31E+01 WS 01 59073 03/19/01 Ce-141 2. 36E+00 2.OOE+00 6. 66E+00 WS 01 59073 03/19/01 Ce-144 -1. 60E+01 7.26E+00 2. 68E+01 WS 01 59073 03/19/01 Co-57 -0.41E+00 0.89E+00 3. 14E+00 WS 01 59073 03/19/01 Co-58 -0. 66E+00 1.30E+00 4. 97E+00 WS 01 59073 03/19/01 Co-60 -0. 63E+00 1.30E+00 5. 20E+00 WS 01 59073 03/19/01 Cr-51 -1.20E+01 1.23E+01 4. 51E+01 WS 01 59073 03/19/01 Cs-134 -0. 31E+00 1. 15E+00 4.42E+00 WS 01 59073 03/19/01 Cs-137 -0. 20E+00 1. 38E+00 5. 06E+00 WS 01 59073 03/19/01 Fe-59 -4. 89E+00 3. 91E+00 1. 61E+01 WS 01 59073 03/19/01 1-131 4. 62E+00 2.45E+00 7. 89E+00 WS 01 59073 03/19/01 K-40 3. 13E+02 3. 45E+01 6.90E+01
- WS 01 59073 03/19/01 Mn-54 -0. 55E+00 1. 09E+00 4. 24E+00 WS 01 59073 03/19/01 Ru-103 -0 .48E+00 1.26E+00 4. 68E+00 WS 01 59073 03/19/01 Ru-106 -1. 57E+01 1. 14E+01 4.48E+01 WS 01 59073 03/19/01 Sb-124 4. 43E+00 3. 62E+00 1. 23E+01 WS 01 59073 03/19/01 Se-75 0.OOE+00 1. 58E+00 5. 55E+00 WS 01 59073 03/19/01 Zn-65 -1.39E+00 2. 50E+00 9. 89E+00 WS 01 59073 03/19/01 Zr-95 -1. 85E+00 1. 76E+00 7.24E+00 WS 01 59672 03/19/01 H-3 -2. 12E+02 3. 55E+02 1. 23E+03 WS 01 59548 04/16/01 Th-232 0. 57E+00 5. 80E+00 2. 09E+01 WS 01 59548 04/16/01 Ag-11CM -1.70E+00 2. 16E+00 8. 22E+00 WS 01 59548 04/16/01 Ba-140 2.72E+00 2.49E+00 8. 63E+00 WS 01 59548 04/16/01 Be-7 -4. 02E+00 1. 05E+01 3. 89E+01 WS 01 59548 04/16/01 Ce-141 1. 83E+00 2. 33E+00 7 .85E+00 WS 01 59548 04/16/01 Ce-144 3. 84E+00 8.35E+00 2.84E+01 WS 01 59548 04/16/01 Co-57 0. 94E+00 1. 05E+00 3. 52E+00 WS 01 59548 04/16/01 Co-58 -0. 99E+00 1.28E+00 5. 05E+00 WS 01 59548 04/16/01 Co-60 1.08E+00 1. 41E+00 5. 03E+00 WS 01 59548 04/16/01 Cr-51 -2. 13E+01 1.37E+01 5. 12E+01 WS 01 59548 04/16/01 Cs-134 -0.4 6E+00 1.29E+00 4. 95E+00 WS 01 59548 04/16/01 Cs-137 -0. 80E+00 1. 45E+00 5. 43E+00 WS 01 59548 04/16/01 Fe-59 -1. 22E+00 4. 07E+00 1. 58E+01 WS 01 59548 04/16/01 1-131 0. 95E+00 3. 50E+00 1. 22E+01 WS 01 59548 04/16/01 K-40 3.57E+02 3. 58E+01 6.21E+01
- WS 01 59548 04/16/01 Mn-54 1. 17E+00 1. 41E+00 4 .88E+00 WS 01 59548 04/16/01 Ru-103 -1.37E+00 1. 49E+00 5. 61E+00 WS 01 59548 04/16/01 Ru-106 -1. 82E+00 1.37E+01 4. 96E+01 WS 01 59548 04/16/01 Sb-124 0. OOE+00 3. 34E+00 1. 31E+01 WS 01 59548 04/16/01 Se-75 -4. 60E+00 1. 62E+00 6. 30E+00 WS 01 59548 04/16/01 Zn-65 1.35E+01 7. 39E+00 2. 41E+01 WS 01 59548 04/16/01 Zr-95 0.36E+00 2.28E+00 8. 37E+00
- Concentration Greater than 3 Standard Deviations 126
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 01 60135 05/21/01 Th-232 0. 82E+00 2. 50E+00 2.29E+01 WS 01 60135 05/21/01 Ag-IIOM -1. 16E+00 0. 86E+00 1. 99E+00 WS 01 60135 05/21/01 Ba-140 -0. 96E+00 1. 86E+00 6.96E+00 WS 01 60135 05/21/01 Be-'7 -5. 31E+00 6.07E+00 2. 18E+01 WS 01 60135 05/21/01 Ce-141 -1. 90E+00 1.4 6E+00 5. 09E+00 WS 01 60135 05/21/01 Ce-144 -5. 09E+00 4.38E+00 1.52E+01 WS 01 60135 05/21/01 Co-57 1 .20E+00 0. 56E+00 1. 81E+00 WS 01 60135 05/21/01 Co-58 0. 57E+00 0. 67E+00 2. 30E+00 WS 01 60135 05/21/01 Co-60 0. 25E+00 0.59E+00 2. 09E+00 WS 01 60135 05/21/01 Cr-51 1. 08E+01 8. 29E+00 2. 75E+01 WS 01 60135 05/21/01 Cs-134 0. 50E+00 0. 61E+00 2. 07E+00 WS 01 60135 05/21/01 Cs-137 0. 47E+00 0. 61E+00 2. 07E+00 WS 01 60135 05/21/01 Fe-59 -0.76E+00 2. 23E+00 8. 07E+00 WS 01 60135 05/21/01 1-131 0. 96E+00 4.01E+00 1.38E+01 WS 01 60135 05/21/01 K-40 2. 81E+02 1. 68E+01 3.25E+01
- WS 01 60135 05/21/01 Mn-54 1.23E+00 0. 63E+00 2. 03E+00 WS 01 60135 05/21/01 Ru-103 5. 90E-02 0. 84E+00 2. 93E+00 WS 01 60135 05/21/01 Ru-106 -4. 04E+00 6.08E+00 2. 17E+01 WS 01 60135 05/21/01 Sb-124 0. 43E+00 1. 44E+00 5.22E+00 WS 01 60135 05/21/01 Se-75 0. 62E+00 0. 92E+00 3. 09E+00 01 60135 05/21/01 Zn-65 -1. 56E+00 1.34E+00 5. OOE+00 WS 05/21/01 Zr-95 -2. 19E+00 1.21E+00 4. 58E+00 01 60135 WS ws 01 60632 06/19/01 Th-232 3. 89E+00 3.79E+00 1.27E+01 WS Ag-IIOM -0. 80E+00 0. 94E+00 3. 50E+00 01 60632 06/19/01 WS -2.23E+00 1.26E+00 5. 13E+00 01 60632 06/19/01 Ba-140 WS 06/19/01 Be-7 -0. 97E+00 7. 05E+00 2. 46E+01 01 60632 WS -1.26E+00 1. 40E+00 4.83E+00 01 60632 06/19/01 Ce-141 WS 06/19/01 Ce-144 -6. 08E+00 5.26E+00 1.82E+01 01 60632 WS -2. 10E-02 0. 66E+00 2. 26E+00 01 60632 06/19/01 Co-57 WS 0. 24E+00 0. 74E+00 2 01 60632 06/19/01 Co-58 .59E+00 WS 1.06E+00 0. 84E+00 2. 83E+00 01 60632 06/19/01 Co-60 WS 60632 06/19/01 Cr-51 1.86E+01 7. 57E+00 2. 43E+01 01 WS 60632 06/19/01 Cs-134 0. 40E+00 0. 82E+00 2. 83E+00 01 WS -1. 87E+00 0. 74E+00 2. 88E+00 01 60632 06/19/01 Cs-137 WS Fe-59 2. 71E+00 2. 33E+00 7. 85E+00 01 60632 06/19/01 WS 06/19/01 1-131 -1. 83E+00 1. 70E+00 6. 07E+00 01 60632 WS K-40 2 2. 14E+01 4.73E+01 01 60632 06/19/01 .75E+02 WS 0.71E+00 2. 60E+00 01 60632 06/19/01 Mn-54 -0. 39E+00 WS Ru-103 -2. 4 6E+00 0. 85E+00 3. 25E+00 01 60632 06/19/01 WS 60632 06/19/01 Ru-106 -8. 21E+00 7.4 9E+00 2.72E+01 01 WS 0 1. 91E+00 6.95E+00 01 60632 06/19/01 Sb-124 .27E+00 WS Se-75 -0. 4 1E+00 1. 08E+00 3. 71E+00 01 60632 06/19/01 WS Zn-65 -5. 16E+00 4. 09E+00 1. 43E+01 01 60632 06/19/01 WS 60632 06/19/01 Zr-95 0. 80E+00 1.29E+00 4.45E+00 01 WS H-3 -1. 23E+02 4. 37E+02 1. 52E+03 01 61090 06/19/01
- Concentration Greater than 3 Standard Deviations 127
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 01 61212 07/23/01 Th-232 -0.36E+00 4. 33E+00 1. 58E+01 WS 01 61212 07/23/01 Ag-lIOM -0.70E+00 1. 23E+00 4.81E+00 WS 01 61212 07/23/01 Ba-140 0. 48E+00 1. 87E+00 7 . 05E+00 WS 01 61212 07/23/01 Be-7 -7.27E+00 9. 23E+00 3. 45E+01 WS 01 61212 07/23/01 Ce-141 2. 53E+00 2. 18E+00 7.26E+00 WS 01 61212 07/23/01 Ce-144 -6. 52E+00 7. 18E+00 2. 54E+01 WS 01 61212 07/23/01 Co-57 1. 31E+00 0. 97E+00 3. 21E+00 WS 01 61212 07/23/01 Co-58 -0. 89E+00 1. 14E+00 4. 37E+00 WS 01 61212 07/23/01 Co-60 1. 02E+00 1. 07E+00 3.74E+00 WS 01 61212 07/23/01 Cr-51 0. 93E+00 1. 16E+01 4.07E+01 WS 01 61212 07/23/01 Cs-134 0. 39E+00 1. 18E+00 4. 24E+00 WS 01 61212 07/23/01 Cs-137 -0. 16E+00 1. 11E+00 4. 08E+00 WS 01 61212 07/23/01 Fe-59 0. 77E+00 3. 18E+00 1. 18E+01 WS 01 61212 07/23/01 1-131 0. 74E+00 2.88E+00 1. 00E+01 WS 01 61212 07/23/01 K-40 3. 15E+02 3. 19E+01 6.82E+01
- WS 01 61212 07/23/01 Mn-54 -0. 18E+00 1. 02E+00 3. 81E+00 WS 01 61212 07/23/01 Ru-103 -1. 45E+00 1. 19E+00 4. 52E+00 WS 01 61212 07/23/01 Ru-106 -1. 59E+00 9. 58E+00 3. 51E+01 WS 01 61212 07/23/01 Sb-124 -0. 58E+00 3. 13E+00 1.20E+01 WS 01 61212 07/23/01 Se-75 -1. 51E+00 1.44E+00 5. 20E+00 WS 01 61212 07/23/01 Zn-65 -6. 24E+00 2. 87E+00 1.17E+01 WS 01 61212 07/23/01 Zr-95 -0. 41E+00 1.82E+00 6.81E+00 WS 01 61544 08/21/01 Th-232 -2. 98E+00 5. 83E+00 2.19E+01 WS 01 61544 08/21/01 Ag-IIOM 2 . 07E+00 1.80E+00 6.14E+00 WS 01 61544 08/21/01 Ba-140 0. 97E+00 2. 65E+00 9.74E+00 WS 01 61544 08/21/01 Be-7 4. 07E+00 1. 14E+01 4. 05E+01 WS 01 61544 08/21/01 Ce-141 0. 62E+00 2.27E+00 7.79E+00 WS 01 61544 08/21/01 Ce-144 1. 18E+01 9. 12E+00 3.03E+01 WS 01 61544 08/21/01 Co-57 0. 36E+00 1. 08E+00 3. 70E+00 WS 01 61544 08/21/01 Co-58 -1. 90E+00 1. 44E+00 5. 75E+00 WS 01 61544 08/21/01 Co-60 -3. 69E-02 1. 36E+00 5. 30E+00 WS 01 61544 08/21/01 Cr-51 1. 39E+01 1. 39E+01 4.68E+01 WS 01 61544 08/21/01 Cs-134 -2. 93E+00 1. 46E+00 6. 12E+00 WS 01 61544 08/21/01 Cs-137 -2 . 57E+00 1. 57E+00 6.21E+00 WS 01 61544 08/21/01 Fe-59 1. 79E+00 4. 36E+00 1. 59E+01 WS 01 61544 08/21/01 1-131 1.28E+00 2 84E+00 9. 84E+00 WS 01 61544 08/21/01 K-40 3. 00E+02 3. 56E+01 7.17E+01
- WS 01 61544 08/21/01 Mn-54 -1. 02E+00 1 57E+00 5. 93E+00 WS 01 61544 08/21/01 Ru-103 0.68E+00 1. 47E+00 5. 16E+00 WS 01 61544 08/21/01 Ru-106 1. 44E+01 1. 23E+01 4. 17E+01 WS 01 61544 08/21/01 Sb-124 2.41E+00 3. 31E+00 1.20E+01 WS 01 61544 08/21/01 Se-75 -3. 64E+00 1. 94E+00 7. 19E+00 WS 01 61544 08/21/01 Zn-65 -1. 02E+01 8. 32E+00 2.98E+01 WS 01 61544 08/21/01 Zr-95 1. 92E+00 2. 53E+00 8. 85E+00
- Concentration Greater than 3 Standard Deviations 128
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 01 61987 09/17/01 Th-232 3.34E+00 5. 17E+00 1. 80E+01 WS 01 61987 09/17/01 Ag-11CM -1.37E+00 1. 32E+00 5. 32E+00 WS 01 61987 09/17/01 Ba-140 -1.23E+00 2. 36E+00 9. 51E+00 WS 01 61987 09/17/01 Be-7 1. 14E+01 9. 64E+00 3. 25E+01 WS 0l 61987 09/17/01 Ce-141 2.28E+00 2. OOE+00 6. 69E+00 WS 01 61987 09/17/01 Ce-144 -6. 26E+00 7 . 34E+00 2. 60E+01 ws 0l 61987 09/17/01 Co-57 0. 56E+00 0. 92E+00 3. 13E+00 WS 01 61987 09/17/01 Co-58 -0. 26E+00 1. 14E+00 4. 29E+00 WS 01 61987 09/17/01 Co-60 0. 72E+00 1. 33E+00 4. 78E+00 WS 01 61987 09/17/01 Cr-51 2. 11E+00 1. 25E+01 4. 37E+01 WS 01 61987 09/17/01 Cs-134 -1. 66E+00 1. 24E+00 4. 91E+00 WS 01 61987 09/17/01 Cs-137 4. 97E-02 1. 12E+00 4. 06E+00 WS 01 61987 09/17/01 Fe-59 -0. 77E+00 3. 98E+00 1. 49E+01 WS 0l 61987 09/17/01 1-131 1. 33E+00 3. 19E+00 1. 12E+01 WS 01 61987 09/17/01 K-40 2. 60E+02 2. 87E+01 5. 82E+01 WS 01 61987 09/17/01 Mn-54 -1. 71E+00 1. 03E+00 4. 22E+00 WS 01 61987 09/17/01 Ru-103 -0. 88E+00 1. 26E+00 4 .70E+00 WS 01 61987 09/17/01 Ru-106 -9. 71E+00 1. 01E+01 3. 85E+01 WS 01 61987 09/17/01 Sb-124 0. 63E+00 2. 76E+00 1. 05E+01 WS 01 61987 09/17/01 Se-75 -0. 93E+00 1. 48E+00 5. 29E+00 WS 01 61987 09/17/01 Zn-65 -2. 74E+00 2. 95E+00 1. 13E+01 WS 01 61987 09/17/01 Zr-95 2. 70E+00 2. 10E+00 7 05E+00 WS 01 62539 09/17/01 H-3 9. 99E+01 2. 71E+02 8. 78E+02 WS 01 62657 10/22/01 Th-232 2. 18E+00 3. 59E+00 1. 25E+01 WS 01 62657 10/22/01 Ag-IIOM 0. OOE+00 1. 32E+00 4 .76E+00 WS 01 62657 10/22/01 Ba-140 0. 99E+00 2. 10E+00 7 55E+00 WS 01 62657 10/22/01 Be-7 -1.54E+01 9. 32E+00 3 50E+01 WS 01 62657 10/22/01 Ce-141 0. 22E+00 1. 99E+00 6.81E+00 WS 01 62657 10/22/01 Ce-144 -3. 78E+00 6. 60E+00 2 .30E+01 WS 01 62657 10/22/01 Co-57 -0. 86E+00 0. 84E+00 2. 97E+00 WS 01 62657 10/22/01 Co-58 -0. 55E+00 0. 83E+00 3. 17E+00 WS 01 62657 10/22/01 Co-60 -0. 95E+00 1. 13E+00 4 .30E+00 WS 01 62657 10/22/01 Cr-51 4 72E+00 1. 09E+01 3. 74E+01 WS 01 62657 10/22/01 Cs-134 0. 89E+00 0. 87E+00 2. 96E+00 WS 01 62657 10/22/01 Cs-137 -1. 39E+00 1. 03E+00 3. 88E+00 WS 01 62657 10/22/01 Fe-59 -3. 56E+00 2. 73E+00 1 .09E+01 WS 01 62657 10/22/01 1-131 -1.31E+00 3. 38E+00 1. 20E+01 WS 01 62657 10/22/01 K-40 3. 03E+02 2. 37E+01 4.24E+01
- WS 01 62657 10/22/01 Mn-54 -1. 05E+00 0. 88E+00 3. 37E+00 WS 01 62657 10/22/01 Ru-103 -0. 83E+00 1. 04E+00 3. 85E+00 WS 01 62657 10/22/01 Ru-106 -6. 38E+00 8. 87E+00 3. 25E+01 WS 01 62657 10/22/01 Sb-124 -2. O1E+00 2. 08E+00 8. 55E+00 WS 01 62657 10/22/01 Se-75 0. 94E+00 1. 42E+00 4 .80E+00 WS 01 62657 10/22/01 Zn-65 2. 23E+00 4.71E+00 1.60E+01 WS 01 62657 10/22/01 Zr-95 -0. 15E+00 1.67E+00 6.07E+00
- Concentration Greater than 3 Standard Deviations 129
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
- Concentration Greater than 3 Standard Deviations 130
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 01 63060 11/19/01 Th-232 1. 40E+00 3. 64E+00 1. 28E+01 WS 01 63060 11/19/01 Ag-IIOM 2.28E+00 1. 22E+00 3. 94E+00 WS 01 63060 11/19/01 Ba-140 0. 33E+00 1. 96E+00 7. 24E+00 WS 01 63060 11/19/01 Be-7 5. 67E+00 8. 30E+00 2. 86E+01 WS 01 63060 11/19/01 Ce-141 0. 95E+00 1. 84E+00 6. 23E+00 WS 01 63060 11/19/01 Ce-144 4 .48E+00 6. 45E+00 2. 18E+01 WS 01 63060 11/19/01 Co-57 -0. 34E+00 0. 82E+00 2.84E+00 WS 01 63060 11/19/01 Co-58 -0.29E+00 0. 87E+00 3. 25E+00 WS 01 63060 11/19/01 Co-60 1.06E+00 0. 85E+00 2.8 6E+00 WS 01 63060 11/19/01 Cr-51 -8. 68E+00 1. 16E+01 4 .12E+01 WS 01 63060 11/19/01 Cs-134 -0. 19E+00 0. 87E+00 3. 22E+00 WS 01 63060 11/19/01 Cs-137 0. 19E+00 0. 91E+00 3. 24E+00 WS 01 63060 11/19/01 Fe-59 1. 16E+00 2. 65E+00 9. 53E+00 WS 01 63060 11/19/01 1-131 0. 53E+00 2. 81E+00 9. 89E+00 WS 01 63060 11/19/01 K-40 2. 95E+02 2. 35E+01 4.30E+01
- WS 01 63060 11/19/01 Mn-54 -2. 31E+00 0. 85E+00 3. 52E+00 WS 01 63060 11/19/01 Ru-103 -1. 05E+00 1.09E+00 4. 02E+00 WS 01 63060 11/19/01 Ru-106 -6. 67E+00 7. 70E+00 2.89E+01 WS 01 63060 11/19/01 Sb-124 -2. 01E+00 1.84E+00 7 .82E+00 ws 01 63060 11/19/01 Se-75 -8. 56E-02 1.27E+00 4.43E+00 WS 01 63060 11/19/01 Zn-65 -3. 82E+00 2.35E+00 9. 07E+00 Ws 01 63060 11/19/01 Zr-95 -0. 20E+00 1. 63E+00 5. 94E+00 WS 01 63432 12/19/01 Th-232 3. 27E+00 3.54E+00 1.21E+01 WS 01 63432 12/19/01 Ag-IIOM -1. 83E+00 1.38E+00 5. 29E+00 WS 01 63432 12/19/01 Ba-140 -1. 57E+00 1.28E+00 5. 29E+00 WS 01 63432 12/19/01 Be-7 6.04E+00 8.27E+00 2. 83E+01 wS 01 63432 12/19/01 Ce-141 -9. 20E-02 1.76E+00 6. 05E+00 WS 01 63432 12/19/01 Ce-144 1. 18E+00 6.66E+00 2. 28E+01 WS 01 63432 12/19/01 Co-57 1. 74E+00 0. 90E+00 2. 92E+00 WS 01 63432 12/19/01 Co-58 -0.71E+00 0. 91E+00 3. 44E+00 WS 01 63432 12/19/01 Co-60 -0. 38E+00 1.OOE+00 3. 76E+00 Ws 01 63432 12/19/01 Cr-51 -2. 16E+01 9. 92E+00 3. 68E+01 WS 01 63432 12/19/01 Cs-134 0. 24E+00 0. 98E+00 3.49E+00 WS 01 63432 12/19/01 Cs-137 -1.4 9E+00 1. 03E+00 3. 90E+00 Ws 01 63432 12/19/01 Fe-59 -1. 90E+00 2. 74E+00 1. 04E+01 WS 01 63432 12/19/01 1-131 0. 44E+00 1. 84E+00 6.4 1E+00 WS 01 63432 12/19/01 K-40 2. 55E+02 2. 24E+01 4.18E+01
- WS 01 63432 12/19/01 Mn-54 0.29E+00 0. 86E+00 3. 04E+00 WS 01 63432 12/19/01 Ru-103 -0. 28E+00 0. 94E+00 3. 39E+00 WS 01 63432 12/19/01 Ru-106 -0.29E+00 8. 61E+00 3. 08E+01 WS 01 63432 12/19/01 Sb-124 2. 29E+00 2. 09E+00 7 .18E+00 WS 01 63432 12/19/01 Se-75 0. 60E+00 1. 20E+00 4. 09E+00 WS 01 63432 12/19/01 Zn-65 1.70E+00 6.88E+00 2. 32E+01 WS 01 63432 12/19/01 Zr-95 -0. 86E+00 1.86E+00 6.7 9E+00 WS 01 63617 12/19/01 H-3 8. OOE+02 3.80E+02 1. 11E+03
- Concentration Greater than 3 Standard Deviations 131
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 51 58218 01/22/01 Th-232 -3. OOE+00 3.85E+00 1. 47E+01 WS 51 58218 01/22/01 Ag-IlOM 0. 38E+00 1. 30E+00 4. 69E+00 WS 51 58218 01/22/01 Ba-140 -1 . 24E+00 1. 61E+00 6. 50E+00 WS 51 58218 01/22/01 Be-7 -2.86E+00 9. 40E+00 3. 40E+01 WS 51 58218 01/22/01 Ce-141 -1. OOE+00 1. 93E+00 6. 77E+00 WS 51 58218 01/22/01 Ce-144 1. 18E+00 7.09E+00 2.44E+01 WS 51 58218 01/22/01 Co-57 -7.57E-02 0.89E+00 3. 08E+00 WS 51 58218 01/22/01 Co-58 -0. 47E+00 0. 93E+00 3. 56E+00 WS 51 58218 01/22/01 Co-60 -1. 72E+00 1. 12E+00 4. 60E+00 WS 51 58218 01/22/01 Cr-51 -1.73E+01 1.06E+01 3. 96E+01 WS 51 58218 01/22/01 Cs-134 1. 86E-02 0. 95E+00 3. 54E+00 WS 51 58218 01/22/01 Cs-137 0. 61E+00 1.09E+00 3. 83E+00 WS 51 58218 01/22/01 Fe-59 -1. 50E+00 3. 29E+00 1.24E+01 WS 51 58218 01/22/01 1-131 0. 20E+00 2. 29E+00 8. 04E+00 WS 51 58218 01/22/01 K-40 3. 01E+02 2. 74E+01 5.23E+01
- WS 51 58218 01/22/01 Mn-54 1. 35E+00 0. 95E+00 3. 16E+00 WS 51 58218 01/22/01 Ru-103 0. 84E+00 1. 19E+00 4 . 10E+00 WS 51 58218 01/22/01 Ru-106 2. 20E+00 1.06E+01 3. 76E+01 Ws 51 58218 01/22/01 Sb-124 1. 93E+00 2. 26E+00 8. 02E+00 WS 51 58218 01/22/01 Se-75 -2. 96E+00 1. 28E+00 4.88E+00 WS 51 58218 01/22/01 Zn-65 6. 67E+00 5. 72E+00 1. 91E+01 WS 51 58218 01/22/01 Zr-95 -2. 87E+00 1. 90E+00 7.48E+00 WS 51 59074 03/19/01 Th-232 3. 71E+00 4. 37E+00 1. 53E+01 WS 51 59074 03/19/01 Ag-IIOM 1. 10E+00 1. 35E+00 4 .80E+00 WS 51 59074 03/19/01 Ba-140 -2. 20E+00 2. 01E+00 8. 56E+00 WS 51 59074 03/19/01 Be-7 6. 89E+00 1.OOE+01 3. 51E+01 WS 51 59074 03/19/01 Ce-141 -2. 95E+00 1. 90E+00 7 .12E+00 WS 51 59074 03/19/01 Ce-144 -1. 48E+01 8. 03E+00 3. OOE+01 WS 51 59074 03/19/01 Co-57 -1. 11E+00 1. 05E+00 3. 82E+00 Ws 51 59074 03/19/01 Co-58 -1. 09E+00 1. 09E+00 4 45E+00 Ws 51 59074 03/19/01 Co-60 -1. 73E+00 1. 29E+00 5.48E+00 Ws 51 59074 03/19/01 Cr-51 4. 99E+00 1. 06E+01 3. 72E+01 Ws 51 59074 03/19/01 Cs-134 -0. 64E+00 1. 03E+00 4. 19E+00 Ws 51 59074 03/19/01 Cs-137 0.59E+00 1. 04E+00 3. 76E+00 WS 51 59074 03/19/01 Fe-59 0. 53E+00 3. 29E+00 1.25E+01 Ws 51 59074 03/19/01 1-131 2. 30E+00 2.44E+00 8. 35E+00 Ws 51 59074 03/19/01 K-40 2. 42E+02 3. 04E+01 6.35E+01
- WS 51 59074 03/19/01 Mn-54 0. 38E+00 1. 02E+00 3. 74E+00 Ws 51 59074 03/19/01 Ru-103 0. 52E+00 1.16E+00 4 15E+00 Ws 51 59074 03/19/01 Ru-106 -3. 44E+00 1. 07E+01 4. 05E+01 WS 51 59074 03/19/01 Sb-124 -2. 78E+00 2. 60E+00 1. 16E+01 Ws 51 59074 03/19/01 Se-75 1. 83E+00 1.41E+00 4. 71E+00 Ws 51 59074 03/19/01 Zn-65 -7. 88E+00 2. 82E+00 1.25E+01 WS 51 59074 03/19/01 Zr-95 0. 41E+00 1. 88E+00 7 .01E+00 Ws 51 59673 03/19/01 H-3 1.46E+02 3. 65E+02 1.24E+03
- Concentration Greater than 3 Standard Deviations 132
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 51 59549 04/16/01 Th-232 -0.79E+00 3. 45E+00 1. 26E+01 WS 51 59549 04/16/01 Ag-IIOM 1. 42E+00 1. 39E+00 4. 71E+00 WS 51 59549 04/16/01 Ba-140 3. 09E+00 1. 71E+00 5. 48E+00 WS 51 59549 04/16/01 Be-7 -9. 72E+00 8. 57E+00 3. 19E+01 WS 51 59549 04/16/01 Ce-141 3. 21E+00 1.89E+00 6. 19E+00 WS 51 59549 04/16/01 Ce-144 -0. 67E+00 6. 88E+00 2. 37E+01 WS 51 59549 04/16/01 Co-57 1. l1E+00 0. 93E+00 3. 11E+00 WS 51 59549 04/16/01 Co-58 -1. 02E+00 1. 02E+00 3. 86E+00 WS 51 59549 04/16/01 Co-60 0. 39E+00 1. 03E+00 3. 68E+00 WS 51 59549 04/16/01 Cr-51 -1. 73E+01 1.09E+01 3. 97E+01 WS 51 59549 04/16/01 Cs-134 -0.84E+00 0. 84E+00 3. 29E+00 WS 51 59549 04/16/01 Cs-137 -1. 73E+00 1. 03E+00 3. 96E+00 WS 51 59549 04/16/01 Fe-59 -3. 88E+00 2. 61E+00 1. 06E+01 WS 51 59549 04/16/01 1-131 -0. 20E+00 2. 57E+00 9. 02E+00 WS 51 59549 04/16/01 K-40 2. 14E+02 2. 24E+01 4.89E+01
- WS 51 59549 04/16/01 Mn-54 -0. 44E+00 0. 90E+00 3. 35E+00 WS 51 59549 04/16/01 Ru-103 -1. 03E+00 1. 13E+00 4. 16E+00 WS 51 59549 04/16/01 Ru-106 -5. 61E+00 9. 86E+00 3. 58E+01 WS 51 59549 04/16/01 Sb-124 3. 63E+00 2. 25E+00 7. 32E+00 vWS 51 59549 04/16/01 Se-75 -0.70E+00 1.39E+00 4 .87E+00 WS 51 59549 04 /16/01 Zn-65 -8. 80E+00 5.33E+00 1. 90E+01 WS 51 59549 04/16/01 Zr-95 2. 07E+00 1 . 64E+00 5. 4 9E+00 WS 51 60136 05 /21/01 Th-232 -3. 73E+00 2.26E+00 8. 45E+00 WS 51 60136 05 /21/01 Ag-11CM 0. 45E+00 0.86E+00 2. 97E+00 WS 51 60136 05 /21/01 Ba-140 3. 03E+00 1. 96E+00 6.4 6E+00 WS 51 60136 05 /21/01 Be-7 -1. 72E+00 6. 12E+00 2. 15E+01 WS 51 60136 05 /21/01 Ce-141 0. 93E+00 1.59E+00 5. 34E+00 WS 51 60136 05 /21/01 Ce-144 -4.4 9E+00 4.34E+00 1. 51E+01 WS 51 60136 05 /21/01 Co-57 0. 14E+00 0. 58E+00 1. 95E+00 WS 51 60136 05 /21/01 Co-58 0.24E+00 0 .74E+00 2. 56E+00 WS 51 60136 05 /21/01 Co-60 -0. 57E+00 0. 57E+00 2. 17E+00 WS 51 60136 05 /21/01 Cr-51 -0.4 6E+00 8.83E+00 3. 03E+01 WS 51 60136 05 /21/01 Cs-134 0. 85E+00 0. 69E+00 2. 30E+00 WS 51 60136 05 /21/01 Cs-137 0.4 1E+00 0. 61E+00 2. 10E+00 WS 51 60136 05 /21/01 Fe-59 5. 32E+00 2. 20E+00 6. 90E+00 WS 51 60136 05 /21/01 1-131 -1. 65E+00 3. 89E+00 1.36E+01 WS 51 60136 05/21/01 K-40 2. 91E+02 1. 65E+01 3.02E+01
- WS 51 60136 05 /21/01 Mn-54 -0. 15E+00 0. 63E+00 2 . 22E+00 WS 51 60136 05 /21/01 Ru-103 -2. 07E+00 0.83E+00 3. 11E+00 WS 51 60136 05 /21/01 Ru-106 -6. 63E+00 5. 88E+00 2. 13E+01 WS 51 60136 05 /21/01 Sb-124 1.59E+00 1. 67E+00 5. 70E+00 WS 51 60136 05 /21/01 Se-75 0.78E+00 0. 93E+00 3. 11E+00 WS 51 60136 05 /21/01 Zn-65 3. 20E+00 2. 13E+00 6. 69E+00 WS 51 60136 05 /21/01 Zr-95 1.44E+00 1. 13E+00 3.7 6E+00
- Concentration Greater than 3 Standard Deviations 133
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 51 60633 06/18/01 Th-232 -5. 73E+00 3.71E+00 1.40E+01 WS 51 60633 06/18/01 Ag-lIOM -0. 68E+00 1.24E+00 4. 57E+00 WS 51 60633 06/18/01 Ba-140 -1. 81E+00 1. 66E+00 6. 61E+00 WS 51 60633 06/18/01 Be-7 -1. 16E+01 7. 17E+00 2.70E+01 WS 51 60633 06/18/01 Ce-141 0.25E+00 1.53E+00 5.20E+00 WS 51 60633 06/18/01 Ce-144 -3. 50E+00 5 .19E+00 1.80E+01 WS 51 60633 06/18/01 Co-57 0. 67E+00 0 . 68E+00 2.27E+00 WS 51 60633 06/18/01 Co-58 -0. 88E+00 0. 93E+00 3. 49E+00 WS 51 60633 06/18/01 Co-60 1. 23E+00 1. 08E+00 3. 64E+00 WS 51 60633 06/18/01 Cr-51 2. 27E+00 9. 10E+00 3. 12E+01 WS 51 60633 06/18/01 Cs-134 0. 34E+00 0. 88E+00 3. 12E+00 WS 51 60633 06/18/01 Cs-137 1. 32E+00 0.86E+00 2. 83E+00 WS 51 60633 06/18/01 Fe-59 0. 13E+00 2. 56E+00 9. 35E+00 WS 51 60633 06/18/01 1-131 1. 36E+00 2. 16E+00 7. 37E+00 WS 51 60633 06/18/01 K-40 2. 60E+02 2.26E+01 4.52E+01
- WS 51 60633 06/18/01 Mn-54 1. 69E+00 0. 85E+00 2.72E+00 WS 51 60633 06/18/01 Ru-103 1. 31E+00 0. 94E+00 3. 10E+00 WS 51 60633 06/18/01 Ru-106 -0. 37E+00 7. 97E+00 2. 83E+01 WS 51 60633 06/18/01 Sb-124 1. 13E+00 2 17E+00 7 .83E+00 Ws 51 60633 06/18/01 Se-75 -0. 59E+00 1. 21E+00 4.22E+00 WS 51 60633 06/18/01 Zn-65 -2. 59E+00 1. 90E+00 7. 39E+00 WS 51 60633 06/18/01 Zr-95 1. 59E+00 1. 52E+00 5. 17E+00 WS 51 61091 06/19/01 H-3 -2. 10E+02 4. 30E+02 1.51E+03 WS 51 61213 07 /23/01 Th-232 -0. 90E+00 5. 61E+00 2. 06E+01 WS 51 61213 07 /23/01 Ag-11OM 1. 98E+00 1. 81E+00 6. 20E+00 WS 51 61213 07 /23/01 Ba-140 0. OOE+00 2. 30E+00 9. 05E+00 WS 51 61213 07 /23/01 Be-7 -4. 02E+00 1. 01E+01 3. 78E+01 WS 51 61213 07 /23/01 Ce-141 -1.4 8E+00 2. 11E+00 7.47E+00 WS 51 61213 07 /23/01 Ce-144 2. 37E+00 7. 90E+00 2. 71E+01 WS 51 61213 07 /23/01 Co-57 1. 73E+00 1. 02E+00 3. 35E+00 WS 51 61213 07 /23/01 Co-58 0. 52E+00 1. 24E+00 4.49E+00 WS 51 61213 07 /23/01 Co-60 0. 28E+00 1. 26E+00 4.78E+00 WS 51 61213 07 /23/01 Cr-51 1.18E+01 1. 28E+01 4. 36E+01 WS 51 61213 07 /23/01 Cs-134 2. 14E+00 1. 27E+00 4. 11E+00 WS 51 61213 07 /23/01 Cs-137 -2. 00E+00 1. 46E+00 5.70E+00 WS 51 61213 07/23/01 Fe-59 -3. 19E+00 3. 32E+00 1.41E+01 WS 51 61213 07 /23/01 1-131 0. 00E+00 3. 32E+00 1. 18E+01 WS 51 61213 07 /23/01 K-40 3. 27E+02 3. 43E+01 6.03E+01
- WS 51 61213 07/23/01 Mn-54 -1.75E+00 1. 15E+00 4.78E+00 WS 51 61213 07/23/01 Ru-103 -2. 56E+00 1. 40E+00 5. 55E+00 WS 51 61213 07/23/01 Ru-106 -7.01E+00 1. 09E+01 4 .15E+01 WS 51 61213 07/23/01 Sb-124 -0.79E+00 3. 43E+00 1. 37E+01 WS 51 61213 07/23/01 Se-75 -2. 16E+00 1. 67E+00 6. 13E+00 WS 51 61213 07/23/01 Zn-65 -0. 98E+00 2. 68E+00 1. 05E+01 WS 51 61213 07/23/01 Zr-95 -2. 78E+00 2. 12E+00 8. 67E+00
- Concentration Greater than 3 Standard Deviations 134
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 51 61545 08/21/01 Th-232 -7. 15E-02 3. 60E+00 1.30E+01 WS 51 61545 08/21/01 Ag-liIM -0. 32E+00 1. 38E+00 5. 02E+00 WS 51 61545 08/21/01 Ba-140 0. OOE+00 1.28E+00 4 .87E+00 WS 51 61545 08/21/01 Be-7 -1. 68E+01 8. 10E+00 3. 14E+01 WS 51 61545 08/21/01 Ce-141 5. 11E+00 1. 82E+00 5. 79E+00 WS 51 61545 08/21/01 Ce-144 1. 05E+01 6. 58E+00 2. 17E+01 WS 51 61545 08/21/01 Co-57 0. 51E+00 0.86E+00 2. 92E+00 WS 51 61545 08/21/01 Co-58 -0. 12E+00 0. 96E+00 3. 48E+00 WS 51 61545 08/21/01 Co-60 -0. 44E+00 0.86E+00 3. 38E+00 WS 51 61545 08/21/01 Cr-51 -1. OOE+01 8. 96E+00 3. 27E+01 WS 51 61545 08 /21/01 Cs-134 -1. 37E+00 1.OOE+00 3. 91E+00 WS 51 61545 08 /21/01 Cs-137 -0. 31E+00 0. 92E+00 3. 38E+00 WS 51 61545 08 /21/01 Fe-59 -1. 74E+00 2.39E+00 9. 37E+00 WS 51 61545 08 /21/01 1-131 -0. 31E+00 1.83E+00 6.4 9E+00 WS 51 61545 08 /21/01 K-40 3. 56E+02 2. 61E+01 4.43E+01
- WS 51 61545 08 /21/01 Mn-54 -0.78E+00 0 .79E+00 3. 09E+00 WS 51 61545 08 /21/01 Ru-103 0. 30E+00 0. 93E+00 3. 28E+00 WS 51 61545 08 /21/01 Ru-106 -1. 20E+01 8. 93E+00 3. 39E+01 WS 51 61545 08/21/01 Sb-124 3. 65E+00 2. 09E+00 6. 68E+00 WS 51 61545 08 /21/01 Se-75 -1.43E+00 1. 36E+00 4 .87E+00 WS 51 61545 08 /21/01 Zn-65 -2. 12E+00 5. 35E+00 1. 85E+01 WS 51 61545 08 /21/01 Zr-95 -2.70E+00 1.73E+00 6. 74E+00 WS 51 61988 09/17/01 Th-232 -6. 24E+00 6. 04E+00 2. 33E+01 WS 51 61988 09/17/01 Ag-lIOM 4.57E+00 1. 75E+00 5. 08E+00 WS 51 61988 09/17/01 Ba-140 -4.71E+00 3.23E+00 1.40E+01 WS 51 61988 09/17/01 Be-7 1.4 9E+00 1.08E+01 3. 93E+01 WS 51 61988 09/17/01 Ce-141 -3. 68E+00 2.32E+00 8.46E+00 WS 51 61988 09/17/01 Ce-144 -0. 98E+00 7. 39E+00 2. 59E+01 WS 51 61988 09/17/01 Co-57 -0. 62E+00 1. OOE+00 3. 54E+00 WS 51 61988 09/17/01 Co-58 -2. 20E+00 1. 35E+00 5. 63E+00 WS 51 61988 09/17/01 Co-60 1.4 6E+00 1.54E+00 5. 37E+00 WS 51 61988 09/17/01 Cr-51 1. 77E+01 1.25E+01 4.16E+01 WS 51 61988 09/17/01 Cs-134 -1. 07E+00 1.46E+00 5. 70E+00 WS 51 61988 09/17/01 Cs-137 -0. 79E+00 1. 27E+00 4. 92E+00 WS 51 61988 09/17/01 Fe-59 -2. 72E+00 3. 80E+00 1. 57E+01 WS 51 61988 09/17/01 1-131 5. 17E+00 3. 66E+00 1. 21E+01 WS 51 61988 09/17/01 K-40 3. 39E+02 3. 62E+01 6.43E+01
- WS 51 61988 09/17/01 Mn-54 1. 05E+00 1. 31E+00 4. 59E+00 WS 51 61988 09/17/01 Ru-103 -0. 19E+00 1. 42E+00 5. 24E+00 WS 51 61988 09/17/01 Ru-106 1. 67E+00 1. 14E+01 4.17E+01 WS 51 61988 09/17/01 Sb-124 0. OOE+00 3.47E+00 1. 38E+01 WS 51 61988 09/17/01 Se-75 -1. 33E+00 1.79E+00 6. 46E+00 WS 51 61988 09/17/01 Zn-65 -5. 81E+00 3. 21E+00 1. 35E+01 WS 51 61988 09/17/01 Zr-95 2. 57E+00 2.48E+00 8. 51E+00 WS 51 62540 09/17/01 H-3 -2.4 9E+01 2. 69E+02 8.75E+02
- Concentration Greater than 3 Standard Deviations 135
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 51 62658 10/22/01 Th-232 1.68E+00 3.29E+00 1.15E+01 WS 51 62658 10/22/01 Ag-IlOM -0.56E+00 1.17E+00 4.35E+00 WS 51 62658 10/22/01 Ba-140 -0.61E+00 2.12E+00 7.94E+00 WS 51 62658 10/22/01 Be-7 -0.75E+00 8.13E+00 2.89E+01 WS 51 62658 10/22/01 Ce-141 -1.86E+00 1.69E+00 6.00E+00 WS 51 62658 10/22/01 Ce-144 3.56E+00 5.73E+00 1.94E+01 WS 51 62658 10/22/01 Co-57 0.37E+00 0.73E+00 2.49E+00 WS 51 62658 10/22/01 Co-58 8.04E-02 0.85E+00 3.08E+00 WS 51 62658 10/22/01 Co-60 0.13E+00 1.OOE+00 3.60E+00 WS 51 62658 10/22/01 Cr-51 6.54E+00 9.82E+00 3.35E+01 WS 51 62658 10/22/01 Cs-134 -0.34E+00 0.93E+00 3.40E+00 WS 51 62658 10/22/01 Cs-137 0.33E+00 0.79E+00 2.80E+00 WS 51 62658 10/22/01 Fe-59 0.88E+00 2.70E+00 9.69E+00 WS 51 62658 10/22/01 1-131 -0.97E+00 3.OOE+00 1.07E+01 WS 51 62658 10/22/01 K-40 3.66E+02 2.43E+01 3.87E+01 WS 51 62658 10/22/01 Mn-54 -0.18E+00 0.78E+00 2.88E+00 WS 51 62658 10/22/01 Ru-103 -1.93E+00 1.02E+00 3.90E+00 WS 51 62658 10/22/01 Ru-106 -1.07E+00 7.81E+00 2.81E+01 WS 51 62658 10/22/01 Sb-124 -0.74E+00 1.97E+00 7.72E+00 WS 51 62658 10/22/01 Se-75 -1.03E+00 1.20E+00 4.26E+00 WS 51 62658 10/22/01 Zn-65 -2.12E+00 2.03E+00 8.08E+00 WS 51 62658 10/22/01 Zr-95 1.96E+00 1.49E+00 4.98E+00 WS 51 63061 11/19/01 Th-232 -5.38E+00 4.55E+00 1.82E+01 WS 51 63061 11/19/01 Ag-IlOM -0.83E+00 1.53E+00 6.03E+00 WS 51 63061 11/19/01 Ba-140 -0.65E+00 3.24E+00 1.26E+01 WS 51 63061 11/19/01 Be-7 -1.63E+01 1.07E+01 4.21E+01 WS 51 63061 11/19/01 Ce-141 -0.56E+00 2.27E+00 7.94E+00 WS 51 63061 11/19/01 Ce-144 -1.11E+01 7.50E+00 2.71E+01 WS 51 63061 11/19/01 Co-57 1.99E+00 0.94E+00 3.04E+00 WS 51 63061 11/19/01 Co-58 0.13E+00 1.24E+00 4.59E+00 WS 51 63061 11/19/01 Co-60 1.08E+00 1.30E+00 4.60E+00 WS 51 63061 11/19/01 Cr-51 -2.52E+00 1.31E+01 4.69E+01 WS 51 63061 11/19/01 Cs-134 -0.63E+00 1.26E+00 4.87E+00 WS 51 63061 11/19/01 Cs-137 -1.04E+00 1.46E+00 5.49E+00 WS 51 63061 11/19/01 Fe-59 -1.34E+00 4.32E+00 1.67E+01 WS 51 63061 11/19/01 1-131 -1.72E+00 3.90E+00 1.43E+01 WS 51 63061 11/19/01 K-40 2.88E+02 3.42E+01 7.20E+01 WS 51 63061 11/19/01 Mn-54 -0.95E+00 1.21E+00 4.73E+00 WS 51 63061 11/19/01 Ru-103 -0.53E+00 1.47E+00 5.40E+00 WS 51 63061 11/19/01 Ru-106 1.76E+00 1.16E+01 4.20E+01 WS 51 63061 11/19/01 Sb-124 -1.58E+00 3.88E+00 1.54E+01 WS 51 63061 11/19/01 Se-75 0.40E+00 1.61E+00 5.60E+00 WS 51 63061 11/19/01 Zn-65 -9.06E+00 3.54E+00 1.48E+01 WS 51 63061 11/19/01 Zr-95 0.27E+00 2.19E+00 8.09E+00
- Concentration Greater than 3 Standard Deviations 136
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 2001 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEA WATER WS 51 63433 12/19/01 Th-232 -5. 06E+00 3. 51E+00 1. 35E+01 WS 51 63433 12/19/01 Ag-IIOM -1.51E+00 1. 39E+00 5 . 24E+00 WS 51 63433 12/19/01 Ba-140 2. 04E+00 1. 42E+00 4 .70E+00 WS 51 63433 12/19/01 Be-7 -1. 43E+01 8.4 9E+00 3. 20E+01 WS 51 63433 12/19/01 Ce-141 -1.27E+00 1 . 85E+00 6. 45E+00 WS 51 63433 12/19/01 Ce-144 -0.70E+00 7.03E+00 2. 41E+01 WS 51 63433 12/19/01 Co-57 -1. 36E+00 0. 91E+00 3. 22E+00 WS 51 63433 12/19/01 Co-58 0. 11E+00 0. 94E+00 3. 38E+00 WS 51 63433 12/19/01 Co-60 -2.85E-02 0. 98E+00 3. 63E+00 WS 51 63433 12/19/01 Cr-51 -1.49E+01 1. O1E+01 3. 67E+01 WS 51 63433 12/19/01 Cs-134 1. 42E+00 1. 17E+00 3. 92E+00 WS 51 63433 12/19/01 Cs-137 -3.4 6E-02 1. 09E+00 3. 88E+00 WS 51 63433 12/19/01 Fe-59 -4.16E+00 2. 59E+00 1. 04E+01 WS 51 63618 12/19/01 H-3 2. 16E+02 3. 70E+02 1. 10E+03 WS 51 63433 12/19/01 1-131 0. 15E+00 1.92E+00 6.68E+00 WS 51 63433 12/19/01 K-40 2 .8 9E+02 2 44E+01 4. 86E+01 WS 51 63433 12/19/01 Mn-54 0. 11E+00 0.94E+00 3. 34E+00 WS 51 63433 12/19/01 Ru-103 -1. 69E+00 1.06E+00 3. 97E+00 WS 51 63433 12/19/01 Ru-106 -4. 38E+00 8.81E+00 3. 21E+01 WS 51 63433 12/19/01 Sb-124 -2. 66E+00 2.4 1E+00 9. 60E+00 WS 51 63433 12/19/01 Se-75 0. 25E+00 1.47E+00 5 . 02E+00 WS 51 63433 12/19/01 Zn-65 3. 43E+00 2.88E+00 9. 09E+00 WS 51 63433 12/19/01 Zr-95 1. 19E+00 1. 65E+00 5. 72E+00
- Concentration Greater than 3 Standard Deviations 137 of 137}}