Text
VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 April 15, 2002 U.S. Nuclear Regulatory Commission Serial No.02-238 Attention: Document Control Desk NAPS/MPW Washington, D.C. 20555 Docket Nos. 50-338 50-339 License Nos. NPF-4 Gentlemen:
NPF-7 VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNITS 1 AND 2 REVISION TO EMERGENCY PLAN IMPLEMENTING PROCEDURE Pursuant to 10 CFR 50.54(q), enclosed are recent revisions to a North Anna Power Station Emergency Plan Implementing Procedures. The revisions do not implement actions that decrease the effectiveness of our Emergency Plan. The Emergency Plan and Implementing Procedures continue to meet the standards of 10 CFR 50.47(b).
Please update your manual by performing the actions described in Attachment 1, Tabulation of Changes.
Very truly yours, D. A. Heacock Site Vice President Commitments Stated or Implied: None.
Enclosures cc:
U.S. Nuclear Regulatory Commission (2 copies)
Region II Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, GA 30303 Mr. M. J. Morgan NRC Senior Resident Inspector North Anna Power Station
ATTACHMENT 1 TABULATION OF CHANGES VIRGINIA ELECTRIC AND POWER COMPANY REVISION TO NORTH ANNA POWER STATION EMERGENCY PLAN IMPLEMENTING PROCEDURES Enclosed is a recent revision to a North Anna Power Station Emergency Plan Implementing Procedure (EPIP). Please take the following actions in order to keep your manual updated.
REMOVE AND DESTROY DATED INSERT EFFECTIVE DATE EPIP-3.02, Rev. 18 12/17/97 EPIP-3.02, Rev. 19 04/09/02 EPIP-4.01, Rev. 17 10/17/01 EPIP-4.01, Rev. 18 04/09/02 EPIP-4.22, Rev. 13 04/02/93 EPIP-4.22, Rev. 14 04/09/02 EPIP-4.23, Rev. 13 03/13/96 EPIP-4.23, Rev. 14 04/09/02 EPIP-4.30, Rev. 4 01/04/99 EPIP-4.30, Rev. 5 04/09/02 EPIP-2.04, Rev. 3 08/07/92 Note Note: The requirements in EPIP 2.04, Transmittal of Plant, Radiological, Status have been incorporated in to revision 19 of EPIP-3.02.
and Emergency Emerqency Plan Privacy and Proprietary Material has been removed. Reference Generic Letter No. 81-27.
PAGE:
1 NORTH ANNA POWER STATION LIST OF NAPS EMERGENCY PLAN IMPLEMENTATION PROCEDURES CHECK DMIS FOR LATEST DOCUMENT INFORMATION DOCUMENT NUMBER EPIP-1.01 EPIP-1.02 EPIP-1.03 EPIP-1.04 EPIP-1.05 EPIP-1.06 EPIP-2.01 EPIP-2.02 EPIP-3.02 EPIP-3.03 EPIP-3.04 EPIP-3.05 EPIP-4.01 EPIP-4.02 EPIP-4.03 EPIP-4.04 EPIP-4.05 EPIP-4.06 EPIP-4.07 EPIP-4.08 EPIP-4.09 EPIP-4.10 EPIP-4.13 REV 035 011 014 014 016 004 024 014 019 012 015 001 018 012 011 009 009 009 014 013 012 010 009 APPROVAL
- DATE**
02/11/02 09/07/99 09/07/99 09/07/99 09/07/99 09/05/01 09/24/01 01/04/99 04/05/02 12/20/93 07/14/98 09/07/99 04/05/02 07/25/00 12/20/93 11/21/94 01/28/00 12/21/95 09/29/00 07/26/01 07/26/01 04/23/98 09/29/00 EFFECT**
- DATE**
03/14/02 10/01/99 10/01/99 10/01/99 10/01/99 09/05/01 09/26/01 01/29/99 04/09/02 01/01/94 07/20/98 10/01/99 04/09/02 08/02/00 01/01/94 11/28/94 02/04/00 12/28/95 10/06/00 09/13/01 09/13/01 04/28/98 10/06/00 DOCUMENT TITLE EMERGENCY MANAGER CONTROLLING PROCEDURE RESPONSE TO NOTIFICATION OF UNUSUAL EVENT RESPONSE TO ALERT RESPONSE TO SITE AREA EMERGENCY RESPONSE TO GENERAL EMERGENCY PROTECTIVE ACTION RECOMMENDATIONS NOTIFICATION OF STATE AND LOCAL GOVERNMENTS NOTIFICATION OF NRC ACTIVATION OF TECHNICAL SUPPORT CENTER ACTIVATION OF OPERATIONAL SUPPORT CENTER ACTIVATION OF LOCAL EMERGENCY OPERATIONS FACILITY AUGMENTATION OF EMERGENCY RESPONSE ORGANIZATION RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING PROCEDURE RADIATION PROTECTION SUPERVISOR CONTROLLING PROCEDURE DOSE ASSESSMENT TEAM CONTROLLING PROCEDURE EMERGENCY PERSONNEL RADIATION EXPOSURE RESPIRATORY PROTECTION AND KI ASSESSMENT PERSONNEL MONITORING AND DECONTAMINATION PROTECTIVE MEASURES INITIAL OFFSITE RELEASE ASSESSMENT SOURCE TERM ASSESSMENT DETERMINATION OF X/Q OFFSITE RELEASE ASSESSMENT WITH ENVIRONMENTAL DATA
PAGE:
2 NORTH ANNA POWER STATION LIST OF NAPS EMERGENCY PLAN IMPLEMENTATIoN PROCEDURES CHECK DMIS FOR LATEST DOCUMENT INFORMATION DOCUMENT NUMBER 4.14 EPIP-4.14 EPIP-4.15 EPIP-4.16 EPIP-4.17 EPIP-4.18 EPIP-4.21 EPIP-4.22 EPIP-4.23 EPIP-4.24 EPIP-4.25 EPIP-4.26 EPIP-4.28 EPIP-4.30 EPIP-4.31 EPIP-4.33 EPIP-4.34 EPIP-5.01 EPIP-5.03 EPIP-5.04 EPIP-5.05 EPIP-5.07 EPIP-5.08 EPIP-5.09 REV 007 011 014 014 011 008 014 014 011 008 011 007 005 003 003 002 011 016 008 013 011 007 003 APPROVAL
- *DATE*
- 12/20/93 02/18/00 02/18/00 08/12/98 08/12/98 12/20/93 04/05/02 04/05/02 01/25/02 07/23/93 07/26/01 01/09/97 04/05/02 06/20/94 11/28/00 02/18/00 12/11/96 02/18/00 07/20/99 06/25/96 07/25/00 11/28/00 03/26/99 EFFECT**
- DATE**
01/01/94 02/28/00 02/28/00 08/14/98 08/14/98 01/01/94 04/09/02 04/09/02 01/28/02 07/23/93 09/13/01 01/14/97 04/09/02 06/20/94 11/30/00 02/28/00 12/17/96 02/28/00 07/22/99 07/02/96 08/02/00 11/30/00 03/31/99 DOCUMENT TITLE INPLANT MONITORING ONSITE MONITORING OFFSITE MONITORING MONITORING OF EMERGENCY RESPONSE FACILITIES MONITORING OF LEOF EVACUATION AND REMOTE ASSEMBLY AREA MONITORING POST ACCIDENT SAMPLING OF CONTAINMENT AIR POST ACCIDENT SAMPLING OF REACTOR COOLANT GASEOUS EFFLUENT SAMPLING DURING AN EMERGENCY LIQUID EFFLUENT SAMPLING DURING AN EMERGENCY HIGH LEVEL ACTIVITY SAMPLE ANALYSIS TSC/LEOF RADIATION MONITORING SYSTEM USE OF MIDAS CLASS A MODEL USE OF MIDAS CLASS B MODEL HEALTH PHYSICS NETWORK COMMUNICATIONS FIELD TEAM RADIO OPERATOR INSTRUCTIONS TRANSPORTATION OF CONTAMINATED INJURED PERSONNEL PERSONNEL ACCOUNTABILITY ACCESS CONTROL SITE EVACUATION ADMINISTRATION OF RADIOPROTECTIVE DRUGS DAMAGE CONTROL GUIDELINE SECURITY TEAM LEADER CONTROLLING PROCEDURE
PAGE:
3 NORTH ANNA POWER STATION LIST OF NAPS EMERGENCY PLAN IMP1LEMENTATION PROCEDURES CHECK DMIS FOR LATEST DOCUMENT INFORMATION DOCUMENT NUMBER EPIP-6.01 APPROVAL REV
- DATE**
007 05/12/99 EFFECT**
- DATE**
05/17/99 DOCUMENT TITLE RE-ENTRY/RECOVERY GUIDELINE
VIRGINIA POWER NORTH ANNA POWER STATION EMERGENCY PLAN IMPLEMENTING PROCEDURE NUMBER PROCEDURE TITLE REVISION EPIP-3.02 ACTIVATION OF TECHNICAL SUPPORT CENTER 19 (With 14 Attachments)
PAGE 1 of 4 PURPOSE
- 1.
To provide guidance to personnel responsible for TSC Activation.
- 2.
To provide guidance to TSC members._
~,) d ýs't itiLrr1O l This DOciVwA Snoui' 3c V.rled AndAnnu-te(
f' AControlled Source As ReL ulred to pfrform
- Work ENTRY CONDITIONS Any one of the following:
- 1.
Declaration of Alert, Site Area Emergency or General Emergency.
- 2.
Entry from another EPIP.
- 3.
Direction of the Station Emergency Manager.
Approvals on File Effective Date 4 /
/gOo2.
I
STiEPK ACTION/EXPECTED RESPONSE H-H RESPONSE NOT OBTAINED NOTE:
The first person to report procedure and then give it upon his/her arrival.
to the TSC should implement this to the Emergency Administrative Director 1 INITIATE PROCEDURE:
- By:
Date:
Time:
2 CHECK ACCOUNTABILITY IN SERVICE CARD READER -
IF accountability card reader NOT in-service, THEN do the following:
a) Initiate Attachment 1, Entry/
Exit Log.
b)
WHEN Emergency Assembly Area Leaders are directed to report results of accountability, THEN use Attachment 1 to provide badge numbers of personnel in TSC.
3 HAVE PERSONNEL MEETING EITHER OF THE FOLLOWING CRITERIA RECORD INFORMATION ON ATTACHMENT 1, ENTRY/EXIT LOG
"* Entering TSC after accountability completed 4
SET UP TSC USING ATTACHMENT 2 NUMBER PROCEDURE TITLE REVISION EPIP-3.02 ACTIVATION OF TECHNICAL SUPPORT CENTER 19 PAGE 2 of 4 l
ACTION/EXPECTED RESPONSE
[-
RESPONSE NOT OBTAINED NOTE:
- Some of the directors may be in the Control Room with the SEM.
e Minimum staff positions shown on the facility staffing board must be filled prior to TSC activation.
5 DETERMINE STATUS OF MINIMUM REQUIRED TSC STAFF POSITIONS 6
NOTIFY STATION EMERGENCY MANAGER OF TSC MINIMUM STAFFING AND EQUIPMENT STATUS SO THAT TSC MAY BE DECLARED ACTIVATED 7
DETERMINE STATUS OF TSC FULL STAFF POSITIONS IF any positions vacant, THEN do the following:
a) Get EPNL to identify designees for vacant position(s).
b) Compare list of persons notified by automated notification (if available) to determine if any designees for vacant positions are enroute.
c) Attempt to contact personnel using contact numbers in EPNL.
IF any positions vacant, THEN do the following:
a) Get EPNL to identify designees for vacant position(s).
b) Compare list of persons notified by automated notification (if available) to determine if any designees for vacant positions are enroute.
c) Attempt to contact personnel using contact numbers in EPNL.
NUMBER PROCEDURE TITLE REVISION EPIP-3.02 ACTIVATION OF TECHNICAL SUPPORT CENTER 19 PAGE 3 of 4 1-l
ACTION/EXPECTED RESPONSE F-]
8 WHEN STATION EMERGENCY MANAGER DIRECTS TSC DEACTIVATION, THEN SECURE TSC:
a)
Restore TSC to original status using Attachment 2, TSC Set-Up and Take-Down b) Affix completed Attachments to this EPIP:
"* Attachment 1, Entry/Exit Log
"* Attachment 3, page 3, Resource Request Log
"* Attachment 12, Shift Rotation Schedule
"* Attachment 13, Data Sheet for Injured Person
"* Attachment 14, Plant Status 9
TERMINATE EPIP-3.02:
° Give completed EPIP-3.02, forms and other applicable records to the Emergency Procedures Coordinator o Completed by:
Date:
Time:
Retain this procedure deactivated.
-END-NUMBER PROCEDURE TITLE REVISION EPIP-3.02 ACTIVATION OF TECHNICAL SUPPORT CENTER 19 PAGE 4 of 4 RESPONSE NOT OBTAINED F-until TSC l
Enter name, badge number, and time of arrival of personnel in the appropriate columns below.
As personnel exit the TSC, enter departure time and destination in the far right columns.
New line entries should be made for returning personnel.
Continue this log on additional pages as required.
IN OUT (Use 24-Hour Time)
NAME Name:
Date:
Page of NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 ENTRY/EXIT LOG 19 ATTACHMENT PAGE 1
1 of 1 BADGE NO DESTI NATION
- 1.
SET-UP TSC:
a)
Distribute supplies:
"* Position binders from Emergency Admin.
Closet
"* EPIP-3.02 Director Guidelines (Attachments 3 -
10 of this EPIP) b)
Activate the following equipment:
"* Alarm and Utility Printers using Attachment 11
"* CRTs and Terminals
"* PA System
"* Verify Gai-Tronics audible (adjust volume as necessary)
NOTE: The following items are to be completed as you are able.
The EAD is to be informed of those items which have not been accomplished.
c)
Do the following checks and tests:
"* Verify back entrance sealed (blast door CLOSED)
"* Verify photo copier working
"* Check paper level in printer(s), copier(s) and facsimile machine(s)
"* Synchronize the clocks to SPDS time
"* Test telecopier
"* Test Aperture Card Reader/Printer
"* Verify telephones operable d)
Report any discrepancies to the EAD
- 2.
TAKE-DOWN (RESTORE)
TSC:
a)
Restock procedures b)
Turn all CRTs screen brightness down c)
Turn off Alarm and Utility Printers d)
Verify Operations has realigned ventilation system to normal mode e)
Direct HP to perform PT on emergency kits f)
Check emergency supplies and restock as required g)
Arrange for laborers to clean TSC h)
Clean all Status Boards i)
Replace break-away lock(s) j)
Submit work orders on any equipment malfunctions NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 TSC SET-UP AND TAKE-DOWN 19 ATTACHMENT PAGE 2
1 of 1
- 1.
Verify Organization:
a)
Emergency Communicators b)
Administrative Support Team:
"* Administrative Support Team Leader
"* Safety/Loss Prevention Support (OSC)
"* Clerks c)
TSC Logkeeper d)
Security Team:
"* Security Shift Supv.
(Team Leader)
"* Security Officers
- 2.
Assist in logistics of TSC activation and operation.
- 3.
Provide clerical and records support.
- 4.
Ensure TSC Logkeeper maintains chronology of key events, including status changes, management decisions in response to event assessment and response, etc.
- 5.
Ensure TSC accountability is maintained.
- 6.
Direct Security Team activities:
- Personnel Accountability Access control
- LEOF activation
- Liaison with local law enforcement agencies
- Notification of offsite assistance (police, fire and rescue units)
- 7.
Get information regarding any injury and assure it is forwarded to LEOF and CERC.
Use EPIP-3.02, Attachment 13, DATA SHEET FOR INJURED PERSONS.
- 8.
Coordinate acquisition of equipment, supplies and personnel.
Offsite support should be coordinated through the LEOF.
Use Resource Request Log (page 3 of this attachment) to track status.
- 9.
Coordinate waiver or provision for Nuclear Power Station Plant Access Training for offsite agencies called in to assist in emergency response.
- 10. IF ERFCS is NOT operable, THEN make sure EPIP-3.02 Attachment 14, Plant Status, reports are sent to both the LEOF and CERC (e.g.,
via facsimile).
(Get status report form from TSC-LEOF Phonetalker.)
- 11.
Ensure Safety/Loss Prevention Support advises the Station Emergency Manager on fire protection and first aid matters.
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 EMERGENCY ADMINISTRATIVE DIRECTOR GUIDELINE 19 ATTACHMENT PAGE 3
1 of 3
- 12.
Ensure the Security Team Leader advises the SEM on Security matters.
- 13.
Ensure arrangements are made for relief of the following personnel:
- Administrative Support Team Security Team Fire Team First Aid Team
- Emergency Communicators
- 14. Coordinate station shift relief:
a)
Determine relief requirements for the following:
- 1)
Refer to EPIP-3.02, Attachment 12, SHIFT ROTATION SCHEDULE
- 2)
Additional support staff requirements from Emergency Directors b)
Identify standby personnel (personnel who are available but not filling positions as primary responders) c)
Develop shift relief schedule:
"* Use Emergency Personnel Notification List (EPNL) to identify designated qualified personnel (Numbers following position titles on Attachment 12 correspond with position numbers appearing on EPNL.
"* Ask Emergency Directors to help select personnel for assignment
"* Verify personnel are available and capable of responding
"* Consider alternative personnel resources (Surry personnel with similar assignments or persons who can be provided ad hoc training)
"* Consider implementation of a split shift turnover (stagger turnover times by discipline)
"* Record assignments on Attachment 12 d)
Ask SEM to approve schedule e)
Give instructions to standby personnel who are not presently needed (e.g., send home or remain on standby) f)
Notify relief shifts (Refer to EPNL for contact numbers):
- 1)
Consider asking LEOF for assistance in making notifications
- 2)
Notify relief personnel of the following:
"* Reporting time
"* Ingress route to the station
"* Reporting location NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 EMERGENCY ADMINISTRATIVE DIRECTOR GUIDELINE 19 ATTACHMENT PAGE 3
2 of 3
NAME OF ITEM SOURCE/
OR SERVICE:
REQUESTED BY:
CONTACT:
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 RESOURCE REQUEST LOG 19 ATTACHMENT PAGE 3
3 of 3 Status:
- 1. Verify Technical Support Team Organization:
- Team Leader
- Operational Advisor
- Reactor Engineer
- Mechanical Engineer Electrical Engineer
- 2.
Notify Westinghouse (NSSS Vendor).
- 3.
Use ERFCS to assess emergency conditions.
- 4.
Periodically assess need for ERFCS Historical File download to magnetic tape.
The ERFCS archive memory limit is 21 hours2.430556e-4 days <br />0.00583 hours <br />3.472222e-5 weeks <br />7.9905e-6 months <br />.
- 5.
Analyze and develop solutions to problems in the following areas:
Engineering Reactor Physics
- Instrumentation and Control
- 6.
Periodically assess need for Chemistry sampling.
- 7.
Assist in development of procedures as required.
_8. Interface with NRC and aid in resolution of questions concerning licensing requirements.
- 9.
IF LESS THAN one SAMG Decision Maker and three SAMG Evaluators available, THEN initiate actions to augment the TSC staff with qualified personnel.
(Qualified personnel are listed at Positions 475 and 476 on the Emergency Personnel Notification List which is available from the EAD.)
- 10.
IF event transitions into SAMG implementation, THEN do the following:
"* Have the SAMG Evaluators continually review the Diagnostic Flow Chart (DFC) and Severe Challenge Status Tree (SCST),
and assure results are made available to the SEM and EOD.
Consider designating one Evaluator to track DFC and SCST status.
"* Assure the SEM and EOD are advised of SAMG-suggested methods of implementation.
"* Direct the SAMG Evaluators to use the SAMG indicated by the DFC and SCST, as appropriate.
- 11. Assure arrangements are made for relief of Technical Support Team and that the TSC relief shift includes at least one SAMG Decision Maker and three SAMG Evaluators.
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 EMERGENCY TECHNICAL DIRECTOR GUIDELINE 19 ATTACHMENT PAGE 4
I of 1
- 1.
Establish communications with Control Room to obtain operational status and to direct response as required.
- 2.
Ensure TSC on emergency ventilation in accordance with-1-OP-21.10, TSC Emergency Ventilation upon a Safety Injection and/or as required by radiological conditions.
- 3.
Verify availability of Operations personnel in OSC and request additional personnel as required.
- 4.
Use ERFCS to assess emergency conditions.
- 5.
Ensure TSC-Control Room phonetalker in position to maintain communication with the Control Room and update Plant Status boards (as required).
- 6.
Evaluate status of unaffected unit.
- 7.
Assess events for reportability to outside agencies.
- 8.
Provide status change data and recommendations to SEM as required.
- 9.
Assist in procedure development as necessary.
- 10.
IF event transitions into SAMG implementation, THEN do the following:
"* Assure the SEM is kept informed of strategies being considered by the Control Room.
"* Maintain cognizance of the responsibility for directing Operations personnel in the development of possible methods to implement the SAMG recommended (or being considered) by the SAMG Evaluators.
Determine if equipment manipulations being requested by the Control Room should be evaluated by the SAMG Evaluators prior to the activity taking place.
- 11.
Ensure arrangements are made for relief of:
a) Control Room personnel (including on-shift STA) b) Standby Operations personnel in OSC NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 EMERGENCY OPERATIONS DIRECTOR GUIDELINE 19 ATTACHMENT PAGE 5
1 of 1
- 1. Verify emergency response organization (ERO):
- Emergency Operations Director (EOD)
- Emergency Maintenance Director (EMD)
- Emergency Technical Director (ETD)
- Emergency Administrative Director (EAD)
- Radiological Assessment Director (RAD)
- Emergency Procedures Coordinator (EPC)
- Emergency Communicators (3)
- 2.
WHEN ready to activate TSC, THEN do the following:
a)
Announce facility activation to staff b) Identify yourself as SEM c)
Provide initial status briefing NOTE: The following responsibilities may not be delegated:
- Classifying the emergency
- Notifying NRC, State and local governments of emergency status
- Recommending protective measures Authorizing emergency exposure
- 3.
WHEN LEOF is activated, THEN do the following:
a)
Transfer the following responsibilities to the Recovery Manager:
"* Notifying State and local governments of emergency status
"* Recommending offsite protective measures
"* Performing offsite dose projections
"* Providing radiological status to the NRC (after the NRC asks that the Health Physics Network (HPN) be established over ENS) b)
Notify TSC staff that above responsibilities transferred to LEOF.
- 4.
Ensure timely notifications are made to offsite authorities.
- 5.
Approve temporary procedures/changes as required.
Procedures may be changed at the discretion of the SEM during emergency conditions.
- 6.
Use ERFCS to assess emergency conditions and response actions.
- 7.
Periodically reference EPIP-1.01, EMERGENCY MANAGER CONTROLLING PROCEDURE, to assess and manage the emergency.
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 STATION EMERGENCY MANAGER GUIDELINE 19 ATTACHMENT PAGE 6
1 of 2
- 8.
Ensure suitable arrangements for relief of ERO through emergency directors.
- 9.
Keep station personnel informed about event status and their expected actions using Gai-Tronics or by other available means of communication.
- 10.
IF TSC must be evacuated, THEN designate TSC team members who will report to the alternate TSC in the Control
- Room, and those members who will report to the Alternate OSC.
- 11.
IF event transitions into SAMG implementation, THEN take responsibility for authorizing the SAMG strategy to be implemented based on recommendations from the EOD and/or ETD.
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 STATION EMERGENCY MANAGER GUIDELINE 19 ATTACHMENT PAGE 6
2 of 2
- 1. Assist SEM in review and adherence to controlling procedures.
- 2.
Monitor Emergency Action Level entry conditions.
- 3.
Assure appropriate procedures are initiated as required.
- 4.
Assure SEM periodically updates TSC staff and station personnel on the following:
Emergency status Mitigation goals and techniques Direction of overall response
- 5.
Assure Emergency Communicators make periodic updates to offsite authorities as required.
- 6.
Track and hold completed procedures and logs until TSC deactivation.
- 7.
Assure procedures are properly completed and made available to Nuclear Emergency Preparedness for preparation of the Summary Report to the State, and ensure subsequent review by the SNSOC.
The report for a Notification of Unusual Event is due to the State 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> after the event is declared.
All higher classifications require a report within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> after termi nation.
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 EMERGENCY PROCEDURES COORDINATOR GUIDELINE 19 ATTACHMENT PAGE 7
1 of 1
- 1.
Verify Organization:
Dose Assessment Team Offsite Monitoring Team
- Evacuation Monitoring Team Inplant Monitoring Team
- Onsite Monitoring Team
- Sample Analysis Team
- Personnel Monitoring and Decontamination Team
- Chemistry Team
- 2.
Direct HP response using EPIP-4.01, RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING PROCEDURE.
- 3.
Use ERFCS to assess emergency conditions.
- 4.
Direct activities of the following emergency response personnel:
- Radiation Protection Supervisor
- Dose Assessment Team
- Offsite and Evacuation Monitoring Teams
- Chemistry Team
- 5.
Assure communicator is assigned to Health Physics Network (HPN) phone in Dose Assessment Office.
(The Health Physics Network (HPN) is established after the NRC announces it is warranted over the ENS.)
- 6.
Give results of Chemistry sampling to ETD for evaluation.
- 7.
WHEN LEOF activated, THEN do the following:
"* Direct Dose Assessment Team Leader to transfer Offsite Dose Assessment to the LEOF Radiological Assessment Coordinator
"* Transfer direction of Offsite and Evacuation Monitoring Teams to Radiological Assessment Coordinator
- Confer with Radiological Assessment Coordinator for consensus on accident type (to yield consistency in dose assessments).
- 8.
Determine release status and evaluate offsite dose assessment data until assumed by LEOF.
- 9.
Give SEM periodic updates on the following:
Radiological status Emergency exposure NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 RADIOLOGICAL ASSESSMENT DIRECTOR GUIDELINE 19 ATTACHMENT PAGE 8
1 of 2
- 10.
Make recommendation for onsite and offsite protective actions to SEM when appropriate.
- 12. Assist in development of procedures as necessary.
- 13. Assure relief available for HP and Chemistry emergency response personnel.
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 RADIOLOGICAL ASSESSMENT DIRECTOR GUIDELINE 19 ATTACHMENT PAGE 8
2 of 2
- 1.
Verify organization:
a)
Maintenance Support Team:
"* Team Leader
"* Mechanical Department Representative
"* Electrical Department Representative
"* Planning Representative
"* I&C Representative b)
OSC personnel
- 2.
Direct activities of Maintenance Support Team and Damage Control Team:
- Monitor task status and location of teams
- Continually reassess priority assignments with SEM
- 3.
Direct damage control activities using EPIP-5.08, DAMAGE CONTROL GUIDELINE.
- 4.
Periodically update SEM on damage control activities.
- 5.
Assist in procedure development as necessary
- 6.
Ensure arrangements are made for relief of:
- Maintenance Support Team
- OSC personnel NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 EMERGENCY MAINTENANCE DIRECTOR GUIDELINE 19 ATTACHMENT PAGE 9
1 of 1
- 1. NRC Communicator Assume NRC notification responsibility from onshift NRC Communicator.
Continue notifications IAW EPIP-2.02, NOTIFICATION OF NRC.
Use the ERFCS to obtain plant parameter data.
NOTE: Follow-up reports of emergency conditions should be provided to state and local governments approximately every 60 minutes or when there are changes in emergency conditions, unless otherwise agreed upon by the State.
A termination notification must always be transmitted following close-out of the event.
- 2.
State and Local Communicator/LEOF Phonetalker Assume State and local notification responsibility from onshift State and Local Communicator.
Continue notifications IAW EPIP-2.01, NOTIFICATION OF STATE AND LOCAL GOVERNMENTS, until the LEOF/CEOF assumes this function.
"* IF either of the following emergency messages transmitted from TSC:
EPIP-2.01 Attachment 2, Notification of State and Local Governments E-PIP-2.01 Attachment 3, Report of Radiological Conditions to the State THEN ask Administrative Services support to telecopy message(s) to LEOF and CERC (or CERC/CEOF only if CEOF activated).
"* Assure Plant Status forms (EPIP-3.02 Attachment 14, Plant Status) are telecopied to LEOF and CERC (or CERC/CEOF only if CEOF activated) if ERFCS is inoperable or if directed by SEM. 4 may be filled-out in any of the following ways:
s Recorded in Control Room and sent to TSC (e.g., via facsimile).
0 Recorded in TSC by the Plant Status Communicator/Control Room Phonetalker.
n Copied from the Plant Status Boards maintained by the Plant Status Communicator/Control Room Phonetalker.
- 3.
Plant Status Communicator/Control Room Phonetalker Assure Plant Status Boards are maintained, if required.
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 GUIDELINE FOR EMERGENCY COMMUNICATORS 19 ATTACHMENT PAGE 10 1 of 1
NOTE: Both the Alarm and Utility Printers are in the Technical Services Area of the Technical Support Center.
- 1.
SET UP ALARM PRINTER:
a)
Verify alarm modem indicates as follows:
"* Ready LED -
GREEN
"* Carrier LED -
RED b)
Select the affected unit (Unit 1 or Unit 2) on the Alarm printer switch box c)
Verify Online/Offline button indicates OFFLINE d)
Turn Alarm printer power switch ON e)
Depress "ESC 99" f)
Depress the following keys:
- 1) "ESC"
- 2)
Simultaneously depress "BRK" and "I" g)
Verify the Alarm printer prints "BPYAIF h)
Depress the Alarm printer Online/
Offline button to indicate ONLINE c) Change button positions as required.
g)
GO TO the CAUTION prior to Step 3 and perform Step 3.
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 ACTIVATION OF ALARM AND UTILITY PRINTERS 19 ATTACHMENT PAGE 11 1 of 3
- 2.
SET UP UTILITY PRINTER:
a)
Verify utility modem a) Verify power switch at rear indicates as follows:
of modem is ON.
"* Power LED - ON
"* Carrier LED ON b)
Verify all front panel b) Change button positions buttons NOT depressed as required.
c)
Select the affected unit (Unit 1 or Unit 2) on the Utility printer switch box d)
Turn Utility printer power switch ON e)
Depress "ESC 99" f)
Depress the following keys:
- 1)
"ESC"
- 2)
Simultaneously depress "BRK" and "1" g)
Verify the Utility printer g)
GO TO the CAUTION prior prints BPYAIF Step 3 and perform Step 3.
h)
Depress the utility printer Online/Offline button to indicate ONLINE NOTE: The BAUD RATE switch is on the back of the printer.
i)
IF Unit 1 is selected on the i)
IF Unit 2 is selected THEN switch box, THEN do the following:
do the following:
- 1)
Set BAUD rate to 96
- 1)
Set BAUD rate to 96
- 2)
Depress front panel switches
- 2) Depress front panel "ANL" and "ALF" switch to "ANL" j)
GO TO END NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 ACTIVATION OF ALARM AND UTILITY PRINTERS 19 ATTACHMENT PAGE 11 2 of 3
CAUTION:
The following step reprograms the printer and should only when directed by another step in the procedure.
be performed
- 3.
REPROGRAM PRINTER:
a)
Do the following on the side keyboard:
- 1)
"ESC 82"
- 2)
"ESC 87"
- 3)
"ESC 91"
- 4)
"ESC 81"
- 5)
"ESC 93" b)
Depress the following keys:
- 1)
"ESC"
- 2)
Simultaneously depress "BRK" and "1" c)
IF the printer prints "BPYAIF" THEN return to Step 1.h or 2.h as required c) Notify Emergency Administrative Director that printer is out of service AND Set up other printer.
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 ACTIVATION OF ALARM AND UTILITY PRINTERS 19 ATTACHMENT PAGE 11 3 of 3
NOTE: The TSC shift relief complement is normally the full staff organization (positions listed below).
The Station Emergency Manager has the authority to modify this organization.
FIRST SHIFT SECOND SHIFT EMERGENCY
RESPONSE
POSITION NAME NAME Station Emergency Manager (401)
Emergency Procedures Coordinator (437)
Emergency Operations Director (401)
NRC ENS Emergency Communicator (405)
TSC-to-LEOF Communicator (406)
Plant Status Communicator (From Operations)
Emergency Technical Director (402)
Technical Support Team Leader (453)
Electrical Engineer (409)
Mechanical Engineer (408)
Reactor Engineer (407)
Operational Advisor (467)
Emergency Maintenance Director (403)
Maintenance Support Team Leader (454)
Mechanical Department Representative (455)
Electrical Department Representative (458)
Planning Representative (456)
I & C Representative (459)
Radiological Assessment Director (404)
Dose Assessment Team Leader (412)
Dose Assessment Team Member (411 Or 438)
Emergency Administrative Director (413)
Administrative Support Team Leader (460)
Administrative Support Team Clerk (463)
Administrative Support Team Clerk (463)
Administrative Support Team Clerk (463)
Technical Support Center Logkeeper (461)
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 SHIFT ROTATION SCHEDULE 19 ATTACHMENT PAGE 12 1 of 1
NAME OF INJURED PERSON:
EMPLOYER:
DATE/TIME OF INJURY:
DESCRIPTION OF EVENT:
SUMMARY
OF INJURIES:
EXPOSURE/CONTAMINATION INFORMATION:
TRANSPORT INFORMATION:
- a.
Transported to:
- b. Mode of transport:
- c.
Time departed station:
- d.
Expected time of arrival at medical facility:
REMARKS:
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 DATA SHEET FOR INJURED PERSONS 19 ATTACHMENT PAGE 13 1 of 1
UNIT TIME MwE REACTOR POWER PRIMARY SYSTEM REACTOR COOLANT SYSTEM (T=TEMPERATURE)
HOTTEST TH OF; HOTTEST TC
°F LOOP "A" DELTA T
%; LOOP "B" DELTA T
%: LOOP "C" DELTA T PRESSURE PSIG; PRESSURIZER LEVEL REACTOR COOLANT PUMP A:
A R
OOC; B:
A R
OOC:
C:
A R
OOC CORE PARAMETERS CORE EXIT THERMOCOUPLE 0 F (Average of highest 5)
MARGIN TO SATURATION:
Ch A -
OF; Ch B --
F SOURCE RANGE COUNTS:
N 31 -
N 32 INTERMEDIATE RANGE AMPS:
N 35 -
N 36 RVLIS: DYNAMIC
%; FULL -
CONTAINMENT TEMPERATURE OF; PRESSURE PSIA; CONTAINMENT ISOLATION PHASE: A B
SUMP LEVEL FT HYDROGEN SECONDARY SYSTEM STEAM GENERATOR LEVEL WIDE RANGE:
A
%: B
%; C (0
100%)
(0 100%)
(0 100%)
NARROW RANGE:
A
%; B
%; C (NR 0 = 75%)
(0 100%)
(0 100%)
(0 100%)
AUXILIARY FEEDWATER:
AUXILIARY FEEDWATER FLOW GPM; CN-TK-1/2 LEVEL_
3A: A R
OOC; 3B: A R
OOC; FW-P-2: A R
OOC ENGINEERED SAFEGUARDS:
OOC; B: A R
OOC; C: A R
OOC; OSRS A:
A R
OOC; B: A R
OOC LHSI A: A R
OOC; B: A R
OOC ISRS A:
A R
OOC; B: A R
OOC OS A:
A R
OOC; B: A R
OOC RS-P-3A: A R
OOC; B: A R
OOC RS-TK-1:
ELECTRICAL DISTRIBUTION EMERGENCY BUS (SUPPLY)
H:
- RSS, DIESEL,
- DEAD, BACKFEED EMERGENCY DIESEL GENERATOR (EDG)
H: OPERATING, AVAILABLE, OOC J: RSS,
- DIESEL, DEAD, BACKFEED J: OPERATING, AVAILABLE, OOC RESERVE STATION SERVICE A: HOT/DEAD B: HOT/DEAD C: HOT/DEAD RADIATION MONITORS PROCESS VENT:
- VENT A:
- VENT B
MAIN STEAM A:
- B:
- C
OTHER (Specify):
OTHER (Specify):
REMARKS:
(24-hour);
DATE:
NUMBER ATTACHMENT TITLE REVISION EPIP-3.02 PLANT STATUS 19 ATTACHMENT PAGE 14 1 of 1 PREPARER:
TIME:-
VIRGINIA POWER NORTH ANNA POWER STATION EMERGENCY PLAN IMPLEMENTING PROCEDURE NUMBER PROCEDURE TITLE REVISION RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING E P IIP-4.01 PROCEDURE 18 (With 1 Attachment)
PAGE 1 of 27 PURPOSE To initially assess emergency conditions, provide recommendations for protective measures, establish an emergency organization and direct Health Physics response to an emergency.
LEVEL. 2 CWaTRUM4 ON This Documen.t Should Bt Verified And Annotateo ro A Controlled &.urce As Required to P orftr Work ENTRY CONDITIONS Activation by EPIP-1.01, EMERGENCY MANAGER CONTROLLING PROCEDURE.
Approvals on File Effective Date b*DŽ1220
-LFSTEP ACTION/EXPECTED RESPOjNSE RESPONSE NOT OBTAINED 1
INITIATE PROCEDURE:
a)
By:
Date:
Time:
b) Assume position of Radiological Assessment Director (RAD) c) Initiate a chronological log to record sequence of events, key decisions, action taken, and other applicable information related to the event 2
GO TO THE CONTROL ROOM IF conditions require your presence in another location, THEN inform SEM AND Report to the Control Room immediately upon completion of task.
NOTE:
During the initial stages of the emergency the Operations Shift Supervisor may assume the position of Station Emergency Manager.
3 ASK SEM FOR BRIEFING ON THE FOLLOWING PARAMETERS:
- Plant status o Emergency Action Levels (EALs) exceeded e Emergency Classification NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 2 of 27 F-l
-EIiEH ACTION/EXPECTED RESPONSE F-RESPONSE NOT OBTAINED 4
CHECK IF EMERGENCY FACILITIES ARE BEING ACTIVATED GO TO Step 6.
5 MOVE TO TSC NOTE:
A minimum of 2 (two) Offsite Monitoring Teams must be dispatched (i.e.,
sent into the field) upon a Site Area Emergency or higher emergency class.
6 CHECK HP SUPPORT REQUIRED IF HP support NOT immediately required, THEN do the following:
° WHEN HP support GO TO Step 7.
7 CHECK IF EVENT INVOLVES ACTUAL OR POTENTIAL OFFSITE RELEASE 8
INITIATE SAMPLING OF EFFLUENT PATHWAY 9
DIRECT INITIATION OF EPIP-4.03, DOSE ASSESSMENT TEAM CONTROLLING PROCEDURE required, THEN
- WHEN emergency is terminated, THEN GO TO Step 38.
GO TO Step 25.
IF unable to get effluent sample, THEN initiate source term sampling.
NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 3 of 27 F-
-LIKSTEH ACTION/!EXPECTED RESPONSE 10 DIRECT INITIATION OF EPIP-4.30, USE OF MIDAS CLASS A MODEL 11 DIRECT RPS TO INITIATE EPIP-4.02, RADIATION PROTECTION SUPERVISOR CONTROLLING PROCEDURE 12 DETERMINE EVENT CLASSIFICATION:
13 GIVE ASSESSMENT BASED CLASSIFICATION TO SEM I
RESPONSE NOT OBTAINED IF MIDAS NOT operable, THEN initiate back-up assessment using desk-top calculations:
"* EPIP-4.08, INITIAL OFFSITE RELEASE ASSESSMENT.
"* EPIP-4.09, SOURCE TERM ASSESSMENT.
"* EPIP-4.10, DETERMINATION OF X/O.
NUMBER PROCEDURE TITLE REVISION EPIP-4.01 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 4 of 27 H-ASSESSMENT RESULTS CLASSIFICATION Normal range monitors ONSCALE N/A: Below classification and indicate < 100% TS limits Normal range monitors ONSCALE Notification of Unusual and indicate Ž 100% TS (but < 1000%)
Event
% TS calculations indicate Ž 1000%
Alert Site Boundary dose Ž 100 mrem TEDE Site Area Emergency 500 mrem Thyroid CDE Site Boundary dose Ž 1 Rem TEDE General Emergency or 5 Rem Thyroid CDE I
m I
-LIKJ-t ACTION/EXPECTED RESPONSE
[-1 RESPONSE NOT OBTAINED 14 CHECK NOTIFICATION OF UNUSUAL EVENT IN EFFECT OR EVENT IS BELOW CLASSIFICATION LIMITS:
a)
Report percent Tech.
Spec.
and Site Boundary dose rate to Station Emergency Manager b)
Get backup sample of the effluent release path c) Have sample analyzed using Health Physics Procedures d)
GO TO Step 20 for follow up assessment 15 INITIATE RESPONSE ACTIONS FOR CONDITION IV LIMITING FAULT ACCIDENT:
GO TO Step 15.
b)
IF unavailable, THEN GO TO Step 20.
IF event NOT Limiting Fault, THEN GO TO Step 20.
- Fuel Handling Accident -
GO TO Step 16
- Steam Generator Tube Rupture GO TO Step 17
- Main Steam Line Rupture -
GO TO Step 18
- LOCA GO TO Step 19 NUMBER PROCEDURE TITLE REVISION EPIP-4.01 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 5 of 27 F-l l
-LIIEJ-t ACTION/EXPECTED RESPONSE F-H RESPONSE NOT OBTAINED NOTE:
Analysis of accidents involving decayed spent fuel should include consideration of onsite skin dose due to Kr-85.
16 INITIATE RESPONSE ACTIONS FOR FUEL HANDLING ACCIDENT:
a)
Recommend evacuation of the Fuel Building and affected containment b) Restrict access until radiological assessment can be made c)
Have EPIP-4.06, PERSONNEL MONITORING AND DECONTAMINATION, initiated to monitor individuals evacuated from accident area d)
Report dose assessment (MIDAS or desk-top) results to SEM e)
GO TO Step 21 NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 6 of 27 F-
ACTION/EXPECTED RESPONSE 1-I 17 INITIATE RESPONSE ACTIONS FOR STEAM GENERATOR TUBE RUPTURE:
a)
Get release parameters from SEM:
- 1) Note length of time between initiation of release and when Air Ejector diverted to containment:
(min.)
(if Air Ejector diverted)
- 2)
Number of Steam Generator Relief or Safety Valves which have lifted:
- 3)
Length of time Relief or Safety Valves remained open:
(min.)
- 4)
Number of relief or Safety Valves which may potentially lift:
- 5) Status of main steam supply to the Steam Driven Auxiliary Feedwater Pump:
Steam isolation from "A" S/G at "B" S/G at "C" S/G at
- 6) Current Steam Generator Blowdown pathway:
- 7)
Length of time until blowdown isolated:-(min.)
b)
Check Air Ejector - DIVERTED TO CONTAINMENT RESPONSE NOT OBTAINED (time) b)
IF Air Ejector NOT diverted, THEN GO TO Step 17.d.
c)
Request immediate evacuation of containment building (STEP 17 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.01 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 7 of 27 H-
-EIi1-E ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 17 INITIATE RESPONSE ACTIONS FOR STEAM GENERATOR TUBE RUPTURE: (Continued) d) Check Steam Driven Auxiliary Feedwater Pump (SDAFWP)
Turbine ISOLATED d)
IF SDAFWP Turbine NOT ISOLATED, THEN do the following:
- 1) Ask SEM to isolate main steam supply from affected generator to Steam Driven Auxiliary Feedwater Pump.
- 2) GO TO Step 17.f.
e) Disregard SDAFWPT as a release pathway f)
Ask SEM for placement of individual to report the following data:
- 1)
Initial monitor readings
- 2)
Increase or decrease in Main Steam and SDAFWP exhaust radiation monitors
- 3) Meteorological panel indications g)
Report dose assessment (MIDAS or desk-top) results to SEM (STEP 17 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING PROCEDURE 18 PAGE 8 of 27 H-l l
ACTION/EXPECTED RESPONSE I-I 17 INITIATE RESPONSE ACTIONS FOR STEAM GENERATOR TUBE RUPTURE: (Continued) h) Restrict access in the following areas until survey(s) confirm no radiological hazards:
"* Steam Generator Blowdown Cooler area
"* Steam Generator Blowdown Lines and Vent area
"* Steam Generator Relief Valve area
"* Steam Driven Auxiliary Feedwater Pump Turbine exhaust area
- Powdex Area
- Turbine Building, 303' level
° Main Steam Valve House i) Consider sampling of Steam Generator Blowdown and Main Steam of affected unit j)
Determine potential for liquid release pathway through the Main Steam Safety Valve k) GO TO Step 21 NUMBER PROCEDURE TITLE REVISION EPIP-4.01 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING PROCEDURE 18 PAGE 9 of 27 RESPONSE NOT OBTAINED I-I
ACTION/EXPECTED RESPONSE 18 INITIATE RESPONSE ACTIONS FOR MAIN STEAM LINE RUPTURE:
a)
Ask SEM for release parameters:
- 1) Location of steam break
- 2) Status of actual or potential Main Steam Safety Valve lift
- 3) Number of valves lifted:
- 4) Length of time valves remained open:
(min.)
- 5) Status of Steam Driven Auxiliary Feedwater Pump isolation
- 6) Monitor reading on Main Steam Monitors and Steam Driven Auxiliary Feedwater Pump exhaust radiation monitors b) Check station ventilation vent radiation monitors for release indication b)
IF NO release indicated, THEN do the following:
- 1) Notify SEM that potential for source term development will be evaluated because monitors do not indicate release.
- 2) GO TO Step 18.e.
c) Evaluate release conseq~uences:
- 1) Assess onsite dose rate in area of break (after break is isolated)
- 2) Assess offsite dose rate (STEP 18 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 10 of 27 F-]
RESPONSE NOT OBTAINED H-l
ACTION/EXPECTED RESPONSE 18 INITIATE RESPONSE ACTIONS FOR MAIN STEAM LINE RUPTURE: (Continued) d) Report dose assessment (MIDAS or desk-top) results to SEM e) Determine potential for source term to develop inside containment or from Main Steam Relief Valve lift f) Direct initiation of EPIP-4.22, POST ACCIDENT SAMPLING OF CONTAINMENT AIR AND EPIP-4.23, POST ACCIDENT SAMPLING OF REACTOR COOLANT g)
GO TO Step 21 NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 11 of 27
[-F RESPONSE NOT OBTAINED F-
ACTION/EXPECTED RESPONSE 19 INITIATE RESPONSE ACTIONS FOR LOCA:
a)
Ask SEM for location of break b) Ask SEM for status of Containment Isolation - Phase "A" or "B",
and any leak paths from the containment c)
Recommend evacuation of Auxiliary Building and Safeguards Building to SEM AND Restrict entry until survey(s) confirm no radiological hazard exist d) Determine CHRRMS readings (RMS-165, 166 or RMS-265, 266) e) Check release occurred through monitored pathway(s) e)
Do the following:
- 1) Direct initiation of EPIP-4.03, DOSE ASSESSMENT TEAM CONTROLLING PROCEDURE.
- 2) Assess actual (unmonitored) or potential release from containment.
f)
Report dose assessment (MIDAS or desk-top) results to SEM g)
Direct initiation of EPIP-4.22, POST ACCIDENT SAMPLING OF CONTAINMENT AIR AND EPIP-4.23, POST ACCIDENT SAMPLING OF REACTOR COOLANT h) GO TO Step 21 NUMBER PROCEDURE TITLE REVISION EPIP-4.Ol RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 12 of 27
-I RESPONSE NOT OBTAINED F-
-LIJ-(
ACTION/EXPECTED RESPONSE F-]
RESPONSE NOT OBTAINED 20 INITIATE RESPONSE ACTIONS FOR RADIOLOGICAL RELEASE:
a) Record release pathway(s):
b)
Report dose assessment (MIDAS or desk-top) results to SEM c)
Ask SEM to place an individual at the monitor of interest to report increase or decrease in readings d)
Get sample of effluent pathway e) Analyze samples using normal Health Physics procedures f)
Consider initiation of EPIP-4.26, HIGH LEVEL ACTIVITY SAMPLE ANALYSIS g) Verify that an exposure control individual is available to supply dosimetry h)
Have RPS coordinate HP coverage needed for any of the following activities:
"* Damage Control Teams
"* Emergency Security activities
"* Access control
"* Personnel monitoring
"* Sample analysis i)
Consider having RPS prepare for dispatch of Offsite Monitoring Teams:
"* Team assembly
"* Preparation of equipment and vehicles GO TO Step 25.
d)
IF sample NOT available, THEN use monitor readings for follow-up assessment.
NUMBER PROCEDURE TITLE REVISION EPIP-4.01 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 13 of 27 H-I
ACTION/EXPECTED RESPONSE F-21 ENSURE 40CFR302 EPA NOTIFICATION REQUIREMENTS AND REPORTABLE QUANTITY CALCULATIONS ARE EVALUATED IN ACCORDANCE WITH NORMAL HP PROCEDURES 22 CHECK IF RESULTS OF OFFSITE RELEASE ASSESSMENT INDICATE SITE BOUNDARY DOSE RATE Ž 50 mrem/hr TEDE OR 250 mrem/hr THYROID CDE 23 DETERMINE OFFSITE PROTECTIVE MEASURES:
a)
Get an estimate of release duration (hours) from SEM b) Direct initiation of EPIP-4.07, PROTECTIVE MEASURES RESPONSE NOT OBTAINED GO TO Step 24.
a)
Use 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> default.
c) Give recommendation to SEM NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING PROCEDURE 18 PAGE 14 of 27 H-
'ýýNýýýýýýO"EPONýI I EýSPONSýENOT
ýOBTAýINE 24 CHECK LEOF (CEOF)
HAS LEAD FOR Do the following:
OFFSITE DOSE ASSESSMENT a) Assure dose assessment result identification number recorded on all pages.
b) Record initials on each page to document approval for issuance of results.
c) Review offsite release assessment results with SEM.
d) Give applicable dose assessment report to State/Local Emergency Communicator:
"* MIDAS Radiological Status Report (2 pages).
"* EPIP-4.03, DOSE ASSESSMENT TEAM CONTROLLING PROCEDURE,.
e) Provide updated dose assessment results when any of the following occur:
"* Every 60 minutes during Alert or higher classification.
"* Within 15 minutes after a classification change.
"* Change in radiological conditions.
NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 15 of 27
ACTION/EXPECTED RESPONSE F-RESPONSE NOT OBTAINED NOTE:
e The following step lists response actions that may have to be coordinated by the RAD.
These actions are not listed in order of priority.
- A minimum of 2 (two) Offsite Monitoring Teams must be dispatched (i.e., sent into the field) upon a Site Area Emergency or higher emergency class.
25 REVIEW HP RESPONSE ACTIONS AND INITIATE RESPONSES ON A PRIORITY BASIS:
WHEN all necessary response actions addressed, THEN GO TO Step 36.
IF HP response action(s) needed, THEN do the following:
Limiting Fault event (LOCA, Main Steam Line RETURN TO Step 15.
- Break, SGTR or Fuel Handling Accident) occurs New radiological release occurs RETURN TO Step 20.
New dose assessment results available RETURN TO Step 12.
Initiate EPIP-4.04, Emergency exposure authorization needed EMERGENCY PERSONNEL EXPOSURE AUTHORIZATION Establishment of HP organization GO TO Step 28.
Dispatch of Offsite Monitoring Team(s)
GO TO Step 29.
Dispatch of Inplant/Onsite Monitoring Team(s)
GO TO Step 31.
Dispatch of LEOF Monitoring Team GO TO Step 30.
Establishment of Access Control Areas GO TO Step 32.
Evaluation of need for respiratory protection GO TO Step 33.
Issuance of radioprotective drugs GO TO Step 34.
Response to injured contaminated individual(s)
GO TO Step 26.
Evacuation of non-essential personnel GO TO Step 35.
Radiological/Meteorological parameters needed Have Attachment 1, from Main Control Room (due to unavailability Radiological Data of data to HP staff from plant computers)
Worksheet, completed.
Turnover duties to relief GO TO Step 27.
NUMBER PROCEDURE TITLE REVISION EPIP-4.01 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 16 of 27 H-l l
ACTION/EXPECTED RESPONSE F-NOTE:
First Aid considerations must be given of individual.
26 INITIATE RESPONSE TO INJURED CONTAMINATED INDIVIDUAL:
a) Check if individual requires offsite medical treatment b) Direct initiation normal HP procedure(s) for response to contaminated injured personnel c) Have RPS review personnel contamination surveys and confirm personnel contaminated d) Check if clothing removal and/or onsite decontamination eliminates contamination AND Internal contamination is NOT suspected RESPONSE NOT OBTAINED priority over decontamination a)
RETURN TO Step 25.
c)
RETURN TO Step 25.
d) IF individual remains contaminated, THEN do the following:
- 1) Have HP Technician the individual.
accompany
- 2)
Recommend transport to MCV.
e)
RETURN TO Step 25 NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 17 of 27 F-
-LIKJ-t ACTION/EXPECTED RESPONSE H-H RESPONSE NOT OBTAINED 27 GIVE TURNOVER TO RELIEF:
a)
WHEN a more Senior Health Physics individual arrives onsite OR Relief -
- NEEDED, THEN brief successor on:
"* Existing plant conditions
"* Offsite release assessment performed
"* Health Physics actions currently underway b) Notify SEM of position change c)
Have relief remain for about 30 minutes to ensure proper turnover d)
RETURN TO Step 25 NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 18 of 27 F-l
-LZJ-C ACTION/EXPECTED RESPONSE H-RESPONSE NOT OBTAINED 28 ESTABLISH HP EMERGENCY ORGANIZATION:
a) Establish Dose Assessment Team:
- 1) Assign 1 Team Leader and 2 Team Members
- 2) Assign EPIP-4.03, DOSE ASSESSMENT TEAM CONTROLLING PROCEDURE b) Establish RPS position AND Assign EPIP-4.02, RADIATION PROTECTION SUPERVISOR CONTROLLING PROCEDURE c)
RETURN TO Step 25 NOTE:
e A minimum of 2 (two) Offsite Monitoring (i.e., sent into the field) upon a Site emergency class.
Teams must be dispatched Area Emergency or higher
- The function of plume tracking/offsite monitoring will be the responsibility of the Radiological Assessment Coordinator upon LEOF activation.
29 ASSESS NEED FOR OFFSITE MONITORING:
a) Evaluate need for offsite monitoring with Dose Assessment Team Leader b)
Check if command and control of Offsite Monitoring Teams has been transferred to the LEOF b)
GO TO Step 29.d.
C) RETURN TO Step 25 (STEP 29 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 19 of 27 H-I l
ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 29 ASSESS NEED FOR OFFSITE MONITORING: (Continued) d)
Have RPS initiate EPIP-4.16, OFFSITE MONITORING e) Evaluate protective measures for offsite teams:
"* TEDE exposure may exceed 10CFR20 annual limits:
Initiate EPIP-4.04, EMERGENCY PERSONNEL RADIATION EXPOSURE
"* Thyroid CDE may exceed 25 Rem: Initiate EPIP-5.07, ADMINISTRATION OF RADIOPROTECTIVE DRUGS
"* Consider placing teams further downwind f)
Discuss provisions with RPS:
- 1) Number of monitoring teams required
- 2) Protective clothing
- 3)
Respiratory protection
- 4) Standby assembly of teams, vehicles and equipment
- 5) Notification of TSC prior to team dispatch
- 6)
Initial team placement
- 7)
Relay of samples/supplies between teams and station
- 8) Relief of teams g)
RETURN TO Step 25 NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 20 of 27
STEP ACTION/EXPECTED RESPONSE 30 ACTIVATE LEOF:
a) Have RPS initiate EPIP-4.18, MONITORING OF LEOF b) Brief RAC on the following parameters:
e Existing plant conditions
- Current offsite dose projections o HP actions underway c) Have Dose Assessment Team Leader brief RAC on the following parameters:
"* Offsite dose assessment
"* Status and location of offsite monitoring teams d) Have Dose Assessment Team Member continue transmittal of status information to LEOF:
"* Meteorological data
"* Monitor data
"* Sample analysis data e)
RETURN TO Step 25 RESPONSE NOT OBTAINED NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 21 of 27 H-
-LIi-L ACTION/EXPECTED RESPONSE F-RESPONSE NOT OBTAINED 31 INITIATE IN-PLANT / ONSITE MONITORING:
a) Review parameters with RPS:
"* Plant conditions
"* Selection of monitoring and sample locations
"* Protective gear (clothing, respirators), dosimetry and special precautions for teams
"* Elevated radiation level readings
"* Access control points
"* Recent survey results b)
Have RPS assign EPIP-4.14, INPLANT MONITORING AND EPIP-4.15, ONSITE MONITORING AND EPIP-4.17, MONITORING OF EMERGENCY RESPONSE FACILITIES AND EPIP-4.18, MONITORING OF LEOF (STEP 31 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 22 of 27
ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED 31 INITIATE IN-PLANT / ONSITE MONITORING:
(Continued) c) Notify RPS c)
GO TO Step 31.d.
AND Ask for repeat survey of emergency response facilities for any of the following conditions:
"* Radiological release occurred
"* Release severity increases
"* Change in plume direction toward facility d) Check if survey data dictates the placement of control points to limit exposure and the spread of contamination e)
RETURN TO Step 25 32 ESTABLISH ACCESS CONTROL AREAS:
a) Evaluate radiological hazards before permitting entrance into access controlled areas b) Arrange for HP coverage of emergency evolutions directed by SEM c) Consider having RPS generate an RWP for controlled area entrance requirements a) GO TO Step 33.
d)
RETURN TO Step 25 NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 23 of 27 F-]
F-
-LJ-t ACTION/EXPECTED RESPONSE HI RESPONSE NOT OBTAINEDI 33 EVALUATE RESPIRATORY PROTECTION REQUIREMENTS:
a) Assess results of air sample analyses b)
Recommend relocation of non-essential personnel from areas where high airborne activity is expected or airborne activity > 0.30 DAC c) Initiate EPIP-4.05, RESPIRATORY PROTECTION AND KI ASSESSMENT d)
RETURN TO Step 25 NOTE:
Administration of Potassium Iodine Tables is preferably done prior to exposure, although administration of the drug within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> is considered acceptable.
34 DETERMINE NEED FOR ISSUANCE OF RADIOPROTECTIVE DRUGS:
a) Direct initiation of EPIP-4.05, RESPIRATORY PROTECTION AND KI ASSESSMENT b) Determine if actual or projected exposure Ž 25 Rem Thyroid CDE c)
Ask SEM for approval to administer radioprotective drugs d) Initiate EPIP-5.07, ADMINISTRATION OF RADIOPROTECTIVE DRUGS e) Get supply of tablets from Health Physics Office b)
RETURN TO Step 25.
c)
IF approval NOT granted, THEN RETURN TO Step 25.
e) Get alternate supply from Surry Power Station.
f)
RETURN TO Step 25 NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 24 of 27
ACTION/EXPECTED RESPONSE
-I 35 EVALUATE NEED TO EVACUATE/SHELTER NON-ESSENTIAL PERSONNEL:
a) Ask SEM for-duration of release b) Determine onsite exposure of non-essential personnel:
- 1) Ask RPS for results of plant surveys and samples
- 2) Check TEDE dose in occupied areas of station
- 3) Determine radioiodine dose commitment from concentration (gCi/cc) based on air sample data and exposure duration:
uCi/cc x 1.57E+6 x _
hrs =
-Rem c) Check results indicate onsite exposure greater than or equal to the following:
Do one of the following:
"* IF exposure greater than 0.5 Rem TEDE or 1 Rem Thyroid
"° IF exposure less than 0.5 Rem TEDE and 1 Rem Thyroid CDE, THEN RETURN TO Step 25 d)
Recommend that the SEM evacuate non-essential personnel (STEP 35 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 25 of 27 RESPONSE NOT OBTAINED STEP
ACTION/EXPECTED RESPONSE F-]
35 EVALUATE NEED TO EVACUATE/SHELTER NON-ESSENTIAL PERSONNEL:
(Continued) e) Assist in evacuation planning:
- 1)
Review offsite release assessments
- 2)
Check plume direction
- 3) Determine appropriate evacuation route and remote assembly area f)
Have RPS assign EPIP-4.21, EVACUATION AND REMOTE ASSEMBLY AREA MONITORING g)
Keep SEM informed about Emergency Assembly Area monitoring status h)
RETURN TO Step 25 36 BRIEF SEM AND RPS ON EMERGENCY STATUS AND RADIOLOGICAL TRENDS 37 CHECK IF EMERGENCY HAS BEEN TERMINATED 38 NOTIFY RPS AND RAC OF EVENT TERMINATION 39 CONSIDER EXTENDED USE OF MONITORING TEAMS FOR DATA COLLECTION RESPONSE NOT OBTAINED RETURN TO Step 11.
NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 26 of 27 iSTEP F-I
ACTION/EXPECTED RESPONSE F-REVIEW RECOVERY PHASE PARAMETERS WITH SEM:
"* Access control to outside contaminated areas
"* Return to normal access control throughout site
"* Additional HP support personnel
"* Radwaste packaging and disposal
"* Assistance with decontamination 41 TERMINATE EPIP-4.01:
"* Give completed EPIPs, forms, and other applicable records to the Nuclear Emergency Preparedness (TSC Emergency Procedures Coordinator if TSC activated)
"* By:
Date:
Time:
-END-NUMBER PROCEDURE TITLE REVISION EPIP-4.O1 RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING 18 PROCEDURE PAGE 27 of 27 E
STEPEH 40 RESPONSE NOT OBTAINED F-
DATE:
Meteorological Data:
RADIATION TIME:
UNIT:
WIND DIRECTION (from):
SECTORS AFFECTED:
WIND SPEED (mph):
PRECIPITATION:
STABILITY CLASS:
SYSTEM MONITORING DATA VENT VENT A (VG-104)
VENT VENT B (VG-113)
PROCESS VENT (GW-102)
AIR EJECTOR (SV-121)
VENT VENT A (VG-174)
VENT VENT B (VG-175)
PROCESS VENT (GW-173)
,cpm cpm cpm cpm mR/hr mR/hr
_mR/ hr (VG-179)
"Ci/sec (VG-180) aCi/sec (GW-178) uCi/sec (SV-221) cpm mR/hr MAIN STEAM:
(MS-170)
(MS-171)
(MS-172)
(MS-270)
(MS-271)
(MS-272)
AFPT:
(MS-176)
(MS-276)
CONTAINMENT MONITORS:
(RMS-161)_
(RMS-164)_
(RMS-162)
(RMS-165)_
(RMS-163)_
(RMS-166)_
R/hr (RMS-261)
(RMS-262)
(RMS-263)
(RMS-264)
(RMS-265)
(RMS-266)_
NUMBER ATTACHMENT TITLE REVISION EPIP-4.01 RADIOLOGICAL DATA WORKSHEET 18 ATTACHMENT PAGE 1
1 of I
VIRGINIA POWER NORTH ANNA POWER STATION EMERGENCY PLAN IMPLEMENTING PROCEDURE NUMBER PROCEDURE TITLE REVISION EPIP-4.22 POST ACCIDENT SAMPLING OF CONTAINMENT AIR 14 (With No Attachments)
PAGE 1 of 7 PURPOSE To provide for monitoring during the collection of a post accident sample of containment air.
F LEV7EL *2 D1b-IIW3uTON This Document Should Be verified And Annotated To A ConTroUed Source As Requlired to Perform Work ENTRY CONDITIONS Any one of the following:
- 1.
Entry directed by the Station Emergency Manager.
- 2.
Entry directed by the Radiation Protection Supervisor.
- 3.
Entry directed by the Radiological Assessment Director.
Approvals on File Effective Date
-LFi-t ACTION/EXPECTED RESPONSE F-I RESPONSE NOT OBTAINED 1 INITIATE EPIP-4.22:
By:
Date:
Time:
NOTE:
The minimum sampling team complement should consist of one Chemistry Team member and one Monitoring Team member at the Containment Air Sampling Panel (CASP, Auxiliary Building 274' level); and, one Chemistry Team member at the Process Control Panel (PCP)/Chemistry Containment Air Sampling Panel (CCP) in Unit 1 Cable Spreading Room.
2 REVIEW SYSTEM DESIGN BASIS:
"* CASP design basis dose rates equal 30 mR/hr at three feet
"* Containment Air Sample design basis dose rates equal 8,000 mR/hr surface and 100 mR/hr at one foot
"* CASP is maintained at a negative pressure
"* Dose rates and airborne contamination levels at the PCP/CCP are not normally affected by the sampling process NUMBER PROCEDURE TITLE REVISION EPIP-4.22 POST ACCIDENT SAMPLING OF CONTAINMENT AIR 14 PAGE 2 of 7 I-l
-LIJ-t ACTION/EXPECTED RESPONSE
[-
RESPONSE NOT OBTAINED 3
CONSIDER PROTECTIVE MEASURES FOR RWP:
a) Dosimetry:
"* Head
"* Trunk
"* Gonad
"* Leg
"* Arm
"* Wrist b) Protective Clothing:
"* Full protective clothing
"* Single gloves
"* Tape all seams c) Respiratory Protection IAW general area conditions in the Auxiliary Building d)
Consider temporary shielding e)
Check emergency exposure authorization required f) Initiate EPIP-4.04, EMERGENCY PERSONNEL RADIATION EXPOSURE 4
DESIGNATE SAMPLE TEAM MEMBERS e) IF emergency exposure authorization NOT required, THEN GO TO Step 4.
NUMBER PROCEDURE TITLE REVISION EPIP-4.22 POST ACCIDENT SAMPLING OF CONTAINMENT AIR 14 PAGE 3 of 7 F-
ACTION/EXPECTED
RESPONSE
RESPONSE NOT OBTAINED NOTE:
Sampling Team members use Chemistry procedures to-sample for containment air.
5 GIVE COPY OF AFFECTED UNIT HIGH RADIATION SAMPLING SYSTEM CONTAINMENT AIR SAMPLING PROCEDURE TO SAMPLE TEAM UNIT 1 - CH-41.310 UNIT 2 - CH-42.310 NOTE:
One team is needed for the "Local" and one for the "Remote" sampling location.
6 BRIEF SAMPLE TEAM:
a)
Review sampling procedure b) Review entry and exit routes c)
Review RWP requirements for PCP/CCP and the CASP:
"* Stay times
"* Protective clothing
"* Dosimetry
"* Respiratory equipment
"* Monitoring d) Review cautions:
"* High radiation levels
"* High activity samples:
Estimate the correct volume of sample to be collected using the gas sampler (RCT)
"* Buddy system
"* Open valves slowly e) Give team a copy of this procedure NUMBER PROCEDURE TITLE REVISION EPIP-4.22 POST ACCIDENT SAMPLING OF CONTAINMENT AIR 14 PAGE 4 of 7
ACTION/EXPECTED RESPONSE 7NOTIFY RPS THAT SAMPLE TEAM IS READY FOR DISPATCH 8
ASK RPS FOR CURRENT PLANT STATUS 9
GIVE UPDATE TO TEAM MEMBERS 10 DISPATCH SAMPLE TEAM 11 NOTIFY THE FOLLOWING INDIVIDUALS ONCE SAMPLE TEAM HAS BEEN DISPATCHED:
"* Station Emergency Manager
"* Radiological Assessment Director
"* Shift Supervisor 12 DO MONITORING CONCURRENT WITH IMPLEMENTATION OF SAMPLING PROCEDURE:
"* Monitor area dose rates while in transit and at panel
"* Monitor dose rates on front of panel and on sample container I-LI RESPONSE NOT OBTAINED NUMBER PROCEDURE TITLE REVISION EPIP-4.22 POST ACCIDENT SAMPLING OF CONTAINMENT AIR 14 PAGE 5 of 7 F-I I
-EJ-E ACTION/EXPECTED RESPONSE I-]
RESPONSE NOT OBTAINED 13 VERIFY SAMPLE PREPARED FOR TRANSPORT:
a)
Sample container labelled with the following information:
"* Sample ID and Unit #
"* Sample volume
"* Date and time
"* Dose rate b)
Glass bottle and syringe assembly put in separate bags/containers 14 CHECK SAMPLE CONTACT READING LESS THAN 10 MR/HR IF sample contact reading GREATER THAN 10 mR/hr, THEN have HP initiate EPIP-4.26, HIGH LEVEL ACTIVITY SAMPLE ANALYSIS.
15 TAKE SAMPLE TO COUNT ROOM:
a)
Use pre-planned route b) Monitor radiological conditions during transit c)
Check dose rates along route within expected levels c)
Do the following:
- 1) Notify RPS.
- 2) Identify route of lowest dose.
d) Maintain ALARA NUMBER PROCEDURE TITLE REVISION EPIP-4.22 POST ACCIDENT SAMPLING OF CONTAINMENT AIR 14 PAGE 6 of 7 F-l
-E!i-t ACTION/EXPECTED RESPONSE F-RESPONSE NOT OBTAINED 16 NOTIFY THE FOLLOWING INDIVIDUALS ONCE SAMPLING HAS BEEN COMPLETED:
"* Radiation Protection Supervisor
"* Shift Supervisor
"° Station Emergency Manager 17 TERMINATE EPIP-4.22:
"* Give completed EPIP-4.22, forms and other applicable records to the Radiation Protection Supervisor Completed by:
Time:
Date:
-END-NUMBER PROCEDURE TITLE REVISION EPIP-4.22 POST ACCIDENT SAMPLING OF CONTAINMENT AIR 14 PAGE 7 of 7 I-
VIRGINIA POWER NORTH ANNA POWER STATION EMERGENCY PLAN IMPLEMENTING PROCEDURE NUMBER PROCEDURE TITLE REVISION EPIP-4.23 POST ACCIDENT SAMPLING OF REACTOR COOLANT 14 (With No Attachments)
PAGE 1 of 7 PURPOSE To collect a post accident sample of reactor coolant from Unit 1 or Unit 2 Reactor Coolant System (RCS).
- LEVEL, 2 DISrRll3'UTION This Document Should Be Verifted And Annotated fo A Contoxlled Source As Requtred to Perform Work ENTRY CONDITIONS Any one of the following:
- 1.
Entry directed by Station Emergency Manager.
- 2.
Entry directed by Radiation Protection Supervisor.
- 3.
Entry directed by Radiological Assessment Director.
Approvals on File Effective Date
) 0,,
-LFSTEP ACTION/EXPECTED RESPONSE I-]
RESPONSE NOT OBTAINED 1 INITIATE EPIP-4.23:
By:
Date:
Time:
2 REVIEW HRSS DESIGN BASES:
Design basis RCS estimated sample dose rates:
0 0
0 1000 Rem/hr surface, undiluted 1 Rem/hr surface, diluted 650 mRem/hr at surface of cask when cover is NOT in place, undiluted
"* Design basis Liquid Sample Panel (LSP) dose rate is 365 mRem/hr at 1 meter
"* LSP is maintained at negative pressure NUMBER PROCEDURE TITLE REVISION EPIP-4.23 POST ACCIDENT SAMPLING OF REACTOR COOLANT 14 PAGE 2 of 7 F-
-LIi1-t ACTION/EXPECTED RESPONSE F-H RESPONSE NOT OBTAINED 3
DETERMINE PROTECTIVE MEASURES:
a)
Dosimetry:
"* Head
"* Trunk
"* Gonad
"* Leg
"* Arm
"* Wrist b)
Protective clothing:
"* Full protective clothing
"* Plastic suit
"* Single gloves
"* Tape all seams c) Respiratory protection IAW general area conditions in the Auxiliary Building d) Consider temporary shielding e) Check emergency exposure authorization required e) IF emergency exposure authorization NOT required, THEN GO TO Step 4.
f) Initiate EPIP-4.04, EMERGENCY PERSONNEL RADIATION EXPOSURE 4
ACTIVATE EMERGENCY RWP (Prepare new RWP if needed)
NUMBER PROCEDURE TITLE REVISION EPIP-4.23 POST ACCIDENT SAMPLING OF REACTOR COOLANT 14 PAGE 3 of 7 I-l
ACTION/EXPECTED RESPONSE NOTE:
One Chemistry Team Member is "Remote" sampling location.
H-RESPONSE NOT OBTAINED needed for the "Local" and one for the 5
DESIGNATE SAMPLE TEAM MEMBERS:
a) Assign one Chemistry Team member per sample team b) Assign one Monitoring Team member per sample team (Designate an In-Plant Monitoring Team member to periodically check on the Chemistry Team members if unable to assign a Monitoring Team member for each sample team.)
6 GIVE SAMPLE TEAM COPY OF DILUTED OR UNDILUTED SAMPLING PROCEDURE FOR AFFECTED UNIT:
"* HIGH RADIATION SAMPLING SYSTEM RCS DILUTED LIQUID SAMPLING POST ACCIDENT CONDITIONS Unit 1 -
"* HIGH RADIATION SAMPLING SYSTEM RCS UNDILUTED LIQUID SAMPLING POST ACCIDENT CONDITIONS Unit 1 -
GIVE SAMPLE TEAM A COPY OF EPIP-4.26, HIGH LEVEL ACTIVITY SAMPLE ANALYSIS NUMBER PROCEDURE TITLE REVISION EPIP-4.23 POST ACCIDENT SAMPLING OF REACTOR COOLANT 14 PAGE 4 of 7 H-l l
ACTION/EXPECTED RESPONSE
[-I RESPONSE NOT OBTAINED 8
BRIEF SAMPLE TEAM:
a)
Review sampling and analysis procedures b) Establish and review entry/exit routes (use ALARA) c) Review requirements for the PCP and the LSP:
"* Stay times
"* Protective clothing
"* Dosimetry
"* Respiratory equipment
"* HP Monitoring d)
Review cautions:
"* High radiation levels
"* High sample activity level
"* High sample pressure
"* Buddy system
"* Open valves slowly e) Direct Chemistry Team Member to notify Monitoring Team Member before introducing primary coolant into the HRSS 9
HAVE SAMPLE TEAM DRESS OUT IAW RWP 10 DISPATCH SAMPLE TEAM NUMBER PROCEDURE TITLE REVISION EPIP-4.23 POST ACCIDENT SAMPLING OF REACTOR COOLANT 14 PAGE 5 of 7
-LFSTEH F-I I
I
-E!i-E ACTION/EXPECTED RESPONSE
-I RESPONSE NOT OBTAINED 11 NOTIFY THE FOLLOWING ONCE SAMPLE TEAM HAS BEEN DISPATCHED:
a) Station Emergency Manager b) Radiological Assessment Director c) Shift Supervisor 12 HAVE SAMPLE ANALYZED:
a)
Refer to EPIP-4.26, HIGH LEVEL ACTIVITY SAMPLE ANALYSIS, for sample dilution b) Transport sample to Hot Lab or HRSS hood for dilutions c)
Implement appropriate Chemistry procedure for analysis d)
Check if diluted HRSS sample is to be flushed back through system for disposal e)
Implement affected unit HIGH RADIATION SAMPLING SYSTEM SAMPLE DISPOSAL OR STORAGE procedure Unit 1 - CH-41.820 Unit 2 - CH-42.820 13 NOTIFY THE FOLLOWING THAT SAMPLING HAS BEEN COMPLETED:
a)
Chemistry Team Leader b)
Radiation Protection Supervisor c) Station Emergency Manager d)
GO TO Step 13.
NUMBER PROCEDURE TITLE REVISION EPIP-4.23 POST ACCIDENT SAMPLING OF REACTOR COOLANT 14 PAGE 6 of 7 F-l l
ACTION/EXPECTED RESPONSE H-H RESPONSE NOT OBTAINED TERMINATE EPIP-4.23:
"* Give completed EPIP-4.23, forms and other applicable records to the Radiation Protection Supervisor Completed by:
Date:
Time:
-END-NUMBER PROCEDURE TITLE REVISION EPIP-4.23 POST ACCIDENT SAMPLING OF REACTOR COOLANT 14 PAGE 7 of 7 14 H-l l
VIRGINIA POWER NORTH ANNA POWER STATION EMERGENCY PLAN IMPLEMENTING PROCEDURE NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
(With 2 Attachments)
PAGE 1 of 23 PURPOSE To provide instructions for execution of the MIDAS Class A Model.
LE L 2 D1S
-'1-moN This Document Shoul.d Se Verkfled And Ansoctard LtoEA Co2 DISTed burcel As Required to Pe.tOrtf Work ENTRY CONDITIONS Any one of the following:
- 1. Entry from EPIP-4.01, RADIOLOGICAL ASSESSMENT DIRECTOR CONTROLLING PROCEDURE.
- 2. Entry from EPIP-4.03, DOSE ASSESSMENT TEAM CONTROLLING PROCEDURE.
- 3. Direction by the Radiological Assessment Director or Radiological Assessment Coordinator.
Approvals on File Effective Date 4/q/),
CONTINUOUS ACTION PAGE-FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT.
The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
-LFJ-E ACTION/EXPECTED RESPONSE I-]
RESPONSE NOT OBTAINED NOTE:
e Dose assessments are required within 15 minutes after a radiological release. MIDAS may underestimate the effects of a release which begins during the current 15-minute period.
"* An abnormal run is one in which a red bar containing messages that meteorological or radiation monitor data is missing appears on the screen.
"* Pressing the DIALOG key causes the terminal to display three lines of text and allows the operator to read system messages during a run.
"* Attachment 2, Design Basis Accident Technical Overview, provides assumptions and default values used in the MIDAS code and EPIPs.
1 INITIATE PROCEDURE:
a)
By:
Date:
Time:
b) Press START/STOP button (the top button near the lower right front of terminal) c) Ensure STOP/START button stays in the engaged position d) Press LOCK key on the keyboard e) Verify LOCK and TEK indicating lights - ON f) Verify MIDAS in one of the following locations being used:
"* North Anna
"* North Anna
"* North Anna HP Office TSC LEOF e)
Do the following:
- 1) Notify RAD/RAC MIDAS terminal malfunctioning.
- 2) Initiate Attachment 1.
f)
IF in CEOF, THEN ensure "Black Box" ABC switch positioned to "A" for North Anna.
g) Verify INITIAL MIDAS RUN NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 2 of 23 F-g)
GO TO Step 5.
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT.
The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
D DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT) 0 North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2. SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
J
ACTIONIEXPECTED RESPONSE RESPONSE NOT OBTAINED 2 DO INITIAL ASSESSMENT:
a) Press RETURN b) Verify USERNAME displayed b)
IF "Local>" appears, THEN type C NMIDAS and RETURN TO Step 2.a.
IF message Local-013" following:
"Local-715 or
- appears, THEN do the
- 1) Press CTRL K keys.
- 2)
WHEN "Local>" appears, type C SMIDAS.
THEN
- 3) Wait for USERNAME to appear.
- 4)
IF USERNAME appears, THEN do the following:
a)
GO TO Step 2.c.
b) Continue using manually entered monitor and met data.
IF USERNAME does NOT appear, THEN do dose assessment using manual EPIPs.
c) Type MIDAS d) Press RETURN e) Verify MIDAS in one of the following locations being used:
"* North Anna HP Office
"* North Anna TSC
"* North Anna LEOF e) IF in
- CEOF, THEN do the following:
- 1)
Type NA (North Anna Site ID).
- 2) Press RETURN.
(STEP 2 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 3 of 23 F-H F-
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE: e MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
North Anna release points are assigned as follows:
Release Point 1:
Containment: ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
ACTION/EXPECTED RESPONSE 2
DO INITIAL ASSESSMENT: (Continued) f)
WHEN the following prompt appears ENTER:
[N1]
[N2]
[T1]
[T2]
[EX]
NORTH ANNA 1 NORTH ANNA 2 NA1 TREND NA2 TREND EXIT THEN type appropriate unit (N1 or N2) g) Press RETURN h) WHEN the following prompt appears
[XX]
[XXXX]
[FM]
[CTRL-Z]
FUNCTION OR TASK CODE FUNCTION AND TASK CODE FUNCTION MENU EXIT
- THEN type TS (touch screen) i)
Press RETURN j) Verify MIDAS connected to North Anna VAX k)
Check if quick assessment desired
- 1) Touch REAL TIME QUICK DOSE PROJECTIONS on the ACCIDENT RUN MENU SELECTION screen j)
IF MIDAS is connected to Surry VAX (i.e., connection made using C SMIDAS),
THEN GO TO Step 7.
k) GO TO Step 5.
m) Touch CONFIRM NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 4 of 23 I-RESPONSE NOT OBTAINED I-
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
- North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
ACTION/EXPECTED RESPONSE F-]
RESPONSE NOT OBTAINED NOTE:
o Meteorological (MET) parameters with good values are backlit in gray with their value under the parameter name.
"* Stability Class is determined using delta temperature (OF).
"* Rate of rainfall (inches per 15 minutes) may be obtained from the Weather Center (Innsbrook, 8-730-3025).
Zero (0) may be entered if data is not available.
However, using zero during periods of rainfall may yield unrepresentative results.
"* EPIP-4.10, DETERMINATION OF X/Q, contains instructions for getting meteorological information, e.g., inches rainfall, when on-site measurements unavailable.
3 ENTER METEOROLOGICAL DATA:
a) Check gray boxes - APPEAR b)
Touch RAIN box c) Put in rate of rainfall (inches per 15 minutes) using the NUM pad d) Touch CONFIRM e)
GO TO Step 3.j f)
Do one of the following:
"* Use LAST MET and touch each box to activate parameter OR
"* Touch box for each MET parameter to be edited and put in value using the NUM pad g) Verify the entered value appears under the parameter name (STEP 3 CONTINUED ON NEXT PAGE) a)
GO TO Step 3.f.
g) Enter parameter value again.
NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 5 of 23 H-
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT) 0 North Anna release points are assigned as follows:
Release Point 1: Containment; ground level (The expressed flow (EX VEL) for Release Point I is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A. Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
ACTION/EXPECTED RESPONSE F-3 ENTER METEOROLOGICAL DATA: (Continued) h)
Ensure values for each of the following parameters are entered (touch the appropriate box and enter the value using the NUM pad as needed):
- Upper and lower wind speed (mph)
- Lower wind direction (degrees)
& Delta temperature (OF)
- Ambient temperature (OF) e Rain (inches per 15 minutes) i) Touch CONFIRM after all MET parameters are correctly entered j) Verify run proceeds into calculation mode j)
IF Red Warning message appears (i.e., rad monitor data invalid),
THEN do the following:
- 1) Touch EXIT.
- 2) RETURN TO Step 2.j.
NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 6 of 23 RESPONSE NOT OBTAINED F-
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE: o MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment I for response actions.
ACTION/EXPECTED RESPONSE
[-I RESPONSE NOT OBTAINED
-_ 4 GET REPORTS:
a) Check if SPECIAL REPORT appears following calculation routine b) Make a print of SPECIAL REPORT (touch "D COPY/S COPY")
c) Touch CONTINUE d)
WHEN page 1 of the RADIOLOGICAL STATUS REPORT appears. THEN press "D COPY/S COPY" e) Touch CONTINUE f)
WHEN page 2 of the RADIOLOGICAL STATUS REPORT appears, THEN press "D COPY/S COPY" g) Touch MORE REPORTS h) Wait for MORE REPORTS SELECTION screen to appear i) Touch box for MET,
- RAD, X/Q, DOSE
SUMMARY
report a)
IF DATA RESULT screens appear, THEN touch CONTINUE multiple times to step through data results and calculation routine until the SPECIAL REPORT appears.
(STEP 4 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 7 of 23 H-I
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
- North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
-LFSTEP ACTION/EXPECTED RESPONSE H-H RESPONSE NOT OBTAINED 4
GET REPORTS: (Continued) j) Touch CONFIRM CAUTION:
The Quick Dose option uses available valid automatic inputs to calculate a dose projection without identifying invalid inputs to the user.
Therefore, if current radiation monitor or flow readings for the release pathway are recognized as invalid, the Quick Dose result will exclude these parameters and may yield an invalid (nonconservative) estimate.
k) Check current radiation monitor and flow readings appear for expected release paths k)
IF MET,
- RAD, X/O, DOSE
SUMMARY
report indicates Quick Dose results are suspect, e.g.,
release path excluded from dose calculation, THEN do the following:
- 1) Record note on RADIOLOGICAL STATUS REPORT indicating it appears to be based on incomplete inputs and is not to be used.
- 2)
Do one of the following:
"* IF MIDAS dose projections to be continued using operator input, THEN GO TO Step 6.
"* IF hand-calculations to be used for evaluation of release consequences, THEN initiate EPIP-4.08, INITIAL OFFSITE RELEASE ASSESSMENT.
- 1) Touch CONTINUE (STEP 4 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 8 of 23 I-l l
l
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
J
-LZIEi-L:
ACTION/EXPECTED RESPONSE I-]
RESPONSE NOT OBTAINED 4
GET REPORTS: (Continued) m) Touch EXIT TO MORE REPORTS n) Touch MORE REPORTS o) Check with RAD/RAC about need for the following specific reports (to support State assessments):
S 0
S DOSE/DOSE RATE PLOTS Additional SPECIAL REPORT Additional RADIOLOGICAL STATUS REPORT p) Touch box for desired report q) Touch CONFIRM r) Check if REPORT PARAMETER SELECTION screen appears s) Set projection time on REPORT PARAMETER SELECTION Screen:
- 1) Touch PROJ.
TIME box to scroll to duration specified by RAD or RAC (Use 2-hour default duration if no duration specified)
- 2) Touch CONFIRM o)
WHEN NO additional reports are
- needed, THEN do the following:
- 1) Touch EXIT twice to return to the ACCIDENT RUN MENU SELECTION SCREEN.
- 2) GO TO Step 16.
r)
GO TO Step 15.
t)
GO TO Step 15 NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 9 of 23 I-l
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
- North Anna release points are assigned as follows:
Release Point 1: Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
-LSTEJ-H ACTION/EXPECTED
RESPONSE
K-I RESPONSE NOT OBTAINED NOTE:
CHRRMS (Unit 1:
RMS-165/166, Unit 2:
RMS-265/266) readings may be used to select MIDAS LOCA accident type.
5 DO ENHANCED DOSE ASSESSMENT WITH DEFAULT DATA:
a) Verify MIDAS system default data to be used (i.e.,
real time meteorological and radiation monitor data, and default accident isotope mix) b) Touch REAL TIME ENHANCED DOSE PROJECTIONS c) Touch CONFIRM d)
WHEN the DBA ACCIDENT TYPE SELECTION screen appears, THEN select accident type specified by RAD/RAC:
"* MSLB (Main Steam Line Break)
"* SGTR (Steam Generator Tube Rupture)
"* FUEL HANDLING (in Fuel Building only)
"* WGTR (Waste Gas Decay Tank Rupture) 0 S
S S
e) f)
a)
GO TO Step 7.
LOCA GAP LOCA MELT LOCKED ROTOR Touch CONFIRM RETURN TO Step 3 NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 10 of 23 H-HOURS CONTAINMENT HIGH RANGE RADIATION AFTER LOCA MONITOR READING (R/hr) 0
>1.5E+4 1.9E+1 29.0 1
>5.5E+3
Ž1.75E+1 28.0 2
>4.OE+3
ŽI.5E+1
Ž7.5 4
>2.75E+3
Ž1.2E+1
Ž7.0 MIDAS ACCIDENT LOCA LOCA LOCA TYPE SELECTION MELT GAP PC
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT.
The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
D OBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
- North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
ACTION/EXPECTED RESPONSE 6 RETURN TO ACCIDENT RUN MENU SELECTION SCREEN:
a)
Touch CONTINUE b) Touch EXIT TO MORE REPORTS c) Touch MORE REPORTS d) Touch EXIT twice to return to the ACCIDENT RUN MENU SELECTION screen NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 11 of 23
[-
RESPONSE NOT OBTAINED F-I l
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
- North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
-E!J-t ACTION/EXPECTED RESPONSE H-H RESPONSE NOT OBTAINED NOTE:
- Each input screen will appear with preselected values backlit in white.
Changes are made by pressing the appropriate box and using the touch screen keypad in the upper right quadrant on the screen.
Keypad entries are entered by touching EN on the keypad.
Times between midnight and 0100 must be entered as 2400 through 2459 using the previous date.
- If radiation monitor data was bad or the source term data was equal to zero during a previous run, a new release option must be selected different from the one previously selected.
7 USE REAL TIME ALL SCREEN DOSE PROJECTIONS TO DO ENHANCED DOSE ASSESSMENT WITH OPTIONAL OPERATOR INPUT DATA:
a) Verify user input is desired for Release Date/Time, Release Option, Monitor Data or Sample Data b) Touch REAL TIME ALL SCREEN DOSE PROJECTIONS c) Touch CONFIRM d)
WHEN MISCELLANEOUS PARAMETERS screen appears, THEN verify default choices are to be used a) RETURN TO Step 5.
d) Adjust choices on the MISCELLANEOUS PARAMETERS screen per RAD/RAC instructions OR Touch MANUAL if manual input of weather data is desired.
e) Touch CONFIRM NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 12 of 23 F-I
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE: e MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT.
The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION. TIME SELECTION.(CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM.
RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT) 0 North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
-LFSTEH ACTION/EXPECTED RESPONSE RESPONSE NOT OBTAINED NOTE:
- Run type is preset to PROJECTED (FORECAST)
DOSE.
- PROJECTION TIME (HOURS) is preset to 1, 2, 4 and 8.
8 INPUT DATE AND TIME INFORMATION:
a)
WHEN RUN MODE AND INTEGRATION TIME SELECTION screen appears, THEN verify current date/time to be used a) IF current date/time NOT to be
- used, THEN do the following:
- 1) Touch START DATE OF INTEGRATION and then use the touch screen NUM pad to enter date in the format:
MO/DY/YR HR:MN.
(MIDAS will provide "/" marks between the pairs of digits for
- month, day and year, and a colon between the pairs of digits for hours and minutes.)
- 2) Touch EN when entry is complete.
b) Touch CONFIRM NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 13 of 23 H-1
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT.
The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
- North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3. TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
ACTION/EXPECTED RESPONSE F-H RESPONSE NOT OBTAINED NOTE:
If rad data was bad or the source term data was equal to zero in a previous run, a new release option must be selected different from the one previously selected.
9 SELECT RELEASE (SOURCE TERM)
OPTION:
a)
Use RELEASE OPTION SELECTION screen b) Choose one of the following release options:
RELEASE OPTIONS SELECTION AND TRANSITION STEPS Radiation monitor data is available
- 1)
Touch MANUAL ENTRY OF EACH for manual entry and/or predictive MONITOR READING dose assessment is desired based on
- 2)
Touch CONFIRM a potential release
- 3)
GO TO Step 10
- 1)
Touch MONITOR DATA FROM Radiation monitor data is available V & F FILE from file
- 2)
Touch CONFIRM
- 3)
GO TO Step 12 Isotopic release rates are available
- 1)
Touch MANUAL ENTRY OF for manual entry and/or predictive ISOTOPE RELEASE RATE dose assessment is desired based on
- 2)
Touch CONFIRM a potential release
- 3)
GO TO Step 11 Isotopic concentrations and flow
- 1)
Touch MANUAL ENTRY OF rates of each release path are known, ISOTOPE CONCENTRATION and/or predictive dose assessment is
- 2)
Touch CONFIRM desired based on a potential release
- 3)
GO TO Step 11
- 1)
Touch DEFAULT DBA ACCIDENT Design Basis Assident Default (DBA)
- 2)
Touch CONFIRM
- 3)
GO TO Step 12 NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 14 of 23 F-l
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
- North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1. TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
-LIj-t ACTION/EXPECTED RESPONSE F-RESPONSE NOT OBTAINED CAUTION:
e Double counting will occur if more than one monitor in each release pathway is entered.
- Default flow rates will automatically be used if flow rates are not entered and may result in overconservative dose projections.
NOTE:
e Monitor readings may be obtained from ERFCS Group Review screens if RMS data is not available to MIDAS.
e CHRRMS (Unit 1:
RMS-165/166, Unit 2:
RMS-256/266) readings may be used to select MIDAS LOCA accident type.
HOURS CONTAINMENT HIGH RANGE RADIATION AFTER LOCA MONITOR READING (R/hr) 0
Ž1.5E+4
ŽI.9E+1
Ž9.0 1
Ž5.5E+3
Ž1.75E+l
Ž8.0 2
Ž4.OE+3
Ž1.5E+1
Ž7.5 4
Ž2.75E+3
Ž1.2E+1
Ž7.0 MIDAS ACCIDENT LOCA LOCA LOCA TYPE SELECTION MELT GAP PC 10 ENTER MONITOR DATA MANUALLY:
(STEP 10 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 15 of 23 H-I
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE: ° MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT.
The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
- North Anna release points are assigned as follows:
Release Point 1:
Containment: ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
j
ATO/XETDRS S
REISPONSENOT OBTAINED 10 ENTER MONITOR DATA MANUALLY: (Continued) a) WHEN the DBA ACCIDENT TYPE SELECTION screen appears, THEN select accident type specified by RAD/RAC:
MSLB (Main Steam Line Break)
"* SGTR (Steam Generator Tube Rupture)
"* FUEL HANDLING (in Fuel Building only)
WGTR (Waste Gas Decay Tank Rupture)
"* LOCKED ROTOR b) Touch CONFIRM c)
WHEN RADIATION MONITOR READINGS screen appears, THEN do the following:
- 1) Touch the box for each monitor to be entered (one at a time)
- 2) Enter radiation and flow values for each monitor using EN on the NUM pad (Enter monitor and flow rate values by making two entries on the NUM pad separated by a comma; e.g.,
1E6,25000 for cpm,flow rate)
- 3)
WHEN entry for one monitor is complete, THEN repeat Steps 10.c.1 through 10.c.2 until all data is entered d)
WHEN all entries have been
- made, THEN touch CONFIRM (STEP 10 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 16 of 23
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
- North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
ACTION/EXPECTED RESPONSE
[-1 RESPONSE NOT OBTAINED 10 ENTER MONITOR DATA MANUALLY:
(Continued) e)
GO TO Step 13 NOTE:
e All four release points require input when using ADVANCED program.
e Zero is an acceptable input for radiation level or flow.
11 ENTER STATION INVENTORY OR SAMPLE DATA:
a) Check if isotopic release RATE is to be used b) Select each isotope AND Enter release rate (for each selection) using the NUM pad c) Touch CONFIRM after all data has been correctly entered a) IF isotopic CONCENTRATION is to be entered, THEN do the following:
- 1) Select each isotope.
- 2) Enter concentration using the NUM pad.
- 3) Enter flow rate in bottom box of center column.
- 4)
GO TO Step 11.c.
c)
IF a data entry error was made.
THEN re-enter the correct data using the NUM pad and touch CONFIRM when complete.
d)
GO TO Step 13 NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 17 of 23 STEP
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT.
The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
- North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
- SEP§ ACTION/EXPECTED RESPONSE
-I RESPONSE NOT OBTAINED NOTE:
o The UNKNOWN MIX option may not appear on all DBA ACCIDENT TYPE SELECTION screens.
- CHRRMS (Unit 1:
RMS-165/166, Unit 2:
RMS-265/266) readings may be used to select MIDAS LOCA accident type.
12 ENTER ACCIDENT TYPE:
a) Verify DBA ACCIDENT TYPE SELECTION screen appears b) Touch box with appropriate accident type:
"* MSLB (Main Steam Line Break)
"* SGTR (Steam Generator Tube Rupture)
"* FUEL HANDLING (in Fuel Building only)
"* WGTR (Waste Gas Decay Tank Rupture) 0 0
0 a) IF accident type screen does NOT appear, THEN GO TO Step 13.
LOCA GAP LOCA MELT LOCKED ROTOR c) Touch CONFIRM NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 18 of 23 HI HOURS CONTAINMENT HIGH RANGE RADIATION AFTER LOCA MONITOR READING (R/hr) 0
Ž1.5E+4
Ž1.9E+1
Ž9.0 1
Ž5.5E+3
Ž1.75E+1
Ž8.0 2
Ž4.0E+3
Ž1.5E+1
Ž7.5 4
Ž2.75E+3
Ž1.2E+l
Ž7.0 MIDAS ACCIDENT LOCA LOCA LOCA TYPE SELECTION MELT GAP PC I
m l
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT) 0 North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
-LIIiJ-t ACTION/EXPECTED RESPONSE
-II RESPONSE NOT OBTAINED 13 ENTER RELEASE TIMING SELECTION:
a) Verify NO "abnormal run" occurred b)
Check if trip occurred GREATER THAN 15 minutes ago c) Touch TRIP DATE box on the RELEASE TIMING SELECTION screen and enter date and time of trip using the NUM pad d)
Check if time of start of release since trip is known e) Touch RELEASE START MINS SINCE TRIP box f) Enter number of minutes using the NUM pad g)
Check if default to 120-minute release duration is desired h)
Touch DURATION box and enter 120 minutes using the NUM pad i)
Touch CONFIRM j)
Verify run is proceeding into calculation mode and data result screen appears a) IF recovering from an "abnormal run",
THEN GO TO Step 14.e.
b) IF time of trip within the past THEN GO TO Step is unknown or 15 minutes, 13.d.
d) GO TO Step 13.g.
g) IF release duration known, THEN do the following:
- 1)
Touch DURATION box.
- 2) Enter number of minutes using the NUM pad.
- 3)
GO TO Step 13.i.
j)
IF meteorological data is not available and the manual entry screen appears, THEN RETURN TO Step 3.
IF error warning messages
- appear, THEN touch EXIT and RETURN TO Step 2.j.
k)
RETURN TO Step 4 NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 19 of 23 H-
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET) o MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1. TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a. Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2. SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
ACTION/EXPECTED RESPONSE 14 RESTART PROCEDURE FOR ABNORMAL RUN:
a) Touch REAL TIME ALL SCREENS DOSE PROJECTIONS box on ACCIDENT RUN MENU SELECTION screen b) Touch CONFIRM c)
WHEN the next screen requesting run type and time selection information appears, THEN touch CONFIRM without making any changes d)
Refer to Step 9 to select a new release option e) Wait for RELEASE TIMING SELECTION screen to appear f)
Touch CONFIRM without making any changes g) Verify that the run proceeds into the calculation mode g)
IF meteorological data NOT available and the manual entry WEATHER SELECTION screen
- appears, THEN RETURN TO Step 3.
h)
RETURN TO Step 4 NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 20 of 23 H-RESPONSE NOT OBTAINED H-l l
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT.
The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET) o MORE REPORTS SELECTION (CONFIRM, EXIT)
North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point I is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
AFWPT Release Point 4:
Vent Vent A. Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image),
which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
ACTION/EXPECTED RESPONSE F-RESPONSE NOT OBTAINED NOTE:
- Displays may be graphic or tabular, depending on-what was selected in the MORE REPORTS menu.
Map features allow the user to put on or take off map overlays using function keys.
e Instructions at the bottom of all graphic and tabular plume menus provide directions on how to move within them.
e Graphic displays of plumes should not be used to determine emergency classifications. Instead, use the printed Special Report information.
o Point of Interest allows the user to select specific points to determine X/Q, dose or dose rate values through the location of the terminal cursor. The cursor is moved using the "joy disk" to any location and then the space bar is toggled to display values.
15 EVALUATE DISPLAYS:
a) Set map scale:
- 1) Check if default distance (miles) to be used
- 2) Touch CONFIRM b) Check use of MAP FEATURES DESIRED
- 1) Touch MAP FEATURES
- 2) Select (highlight) desired options on screen menu
- 3) Touch CONFIRM
- 1) Touch MAP SCALE box and enter miles of interest using NUM pad b) IF use of MAP FEATURES is NOT desired, THEN GO TO Step 15.c.
(STEP 15 CONTINUED ON NEXT PAGE)
NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 21 of 23 F-l
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT. The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT) 0 North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3.
TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
ACTION/EXPECTED RESPONSE F-]
15 EVALUATE DISPLAYS: (Continued) c) Check enlargement of selected area of display - DESIRED:
- 1)
Touch SELECT AREA
- 2)
Touch screen at two points bounding the desired area
- 3)
Touch RESTORE when use of this function is complete d) Check use of POINT OF INTEREST feature - DESIRED:
- 1) Touch POINT OF INTEREST, move cursor to desired location using "joy disk",
and toggle the space bar (Place mouse cross-hairs to desired point and click)
- 2)
WHEN POINT OF INTEREST function complete, THEN move cursor to the bottom right corner of the plot and press the space bar (Place mouse cross-hairs at bottom right corner of plot and click) e) Touch CONTINUE f)
Touch MORE REPORTS g)
RETURN TO Step 4.h 16 CHECK IF MIDAS OPERATIONS CAN BE TERMINATED:
RESPONSE NOT OBTAINED c) IF use of SELECT AREA is NOT desired, THEN GO TO Step 15.d.
d)
IF POINT OF INTEREST is NOT desired, THEN GO TO Step 15.e.
RETURN TO Step 5.
"* Event TERMINATED
"* RAD/RAC directs termination of MIDAS operation NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 22 of 23 F-
CONTINUOUS ACTION PAGE FOR EPIP-4.30 NOTE:
- MIDAS screens have selection boxes that may include RESET, CONFIRM and EXIT.
The RESET box is used to clear any data that was entered before initiating a run, or to return to a previous screen.
When all information on the screen is correct, the CONFIRM box is selected to continue model processing.
The EXIT box exits the modeling process.
Selection screens include:
- ACCIDENT RUN MENU SELECTION (CONFIRM,
- EXIT, RESET)
- MISCELLANEOUS PARAMETERS (CONFIRM, RESET)
- RUN MODE AND INTEGRATION TIME SELECTION (CONFIRM, RESET)
- RELEASE OPTION SELECTION (CONFIRM, RESET)
- DBA ACCIDENT TYPE SELECTION (CONFIRM, RESET)
- RELEASE TIMING SELECTION (CONFIRM, RESET)
- WEATHER SELECTION (CONFIRM, RESET)
- MORE REPORTS SELECTION (CONFIRM, EXIT)
North Anna release points are assigned as follows:
Release Point 1:
Containment; ground level (The expressed flow (EX VEL) for Release Point 1 is "O.OOE+O0" based on no containment release.)
Release Point 2:
Process Vent Release Point 3:
Main Steam Safety Valves, AFWPT Release Point 4:
Vent Vent A, Vent Vent B, Air Ejector
- 1.
TERMINAL INTERFACE CRITERIA IF touch screen feature activated, THEN use touch screen to make entries.
IF a "mouse" is connected to the terminal, THEN do the following when instructed to touch the screen during performance of this procedure:
- a.
Do not touch the screen when prompted to do so by the procedure.
- b.
Use the "mouse" to position cross-hairs at desired location on screen.
- c.
Click the "mouse" after cross-hairs are properly positioned.
NOTE: Copying may take over two minutes.
Using the CONTROL key with the D COPY/S COPY key will produce light text on a black background (reverse image), which may improve the resolution of maps/isopleths.
- 2.
SCREEN PRINT CRITERIA WHEN individual screen print desired, THEN press "D COPY/S COPY" key while screen is displayed.
- 3. TERMINAL MALFUNCTION RESPONSE CRITERIA IF terminal malfunctions, THEN have dose projections made from another terminal.
- 4.
TERMINAL LOCK-UP RESPONSE CRITERIA IF a terminal lock-up occurs, THEN refer to Attachment 1 for response actions.
ACTION/EXPECTED RESPONSE 17 DISENGAGE SYSTEM:
a)
Touch EXIT twice on the ACCIDENT RUN MENU SELECTION screen b) Press "CNTL" and "Z" keys simultaneously c)
WHEN "Local>" appears, THEN type LO d)
Press RETURN e) Press START/STOP button (the top button near the lower right front of terminal) f)
Ensure STOP/START button DISENGAGED 18 TERMINATE EPIP-4.30:
"* Give completed EPIP-4.30, forms and other applicable records to the Radiological Assessment Di rector/Coordinator By:
Date:
Ti me:
-END-NUMBER PROCEDURE TITLE REVISION EPIP-4.30 USE OF MIDAS CLASS A MODEL 5
PAGE 23 of 23
RESPONSE
NOT OBTAINED
-HH
Perform the following actions, in sequence, to recover from terminal or system lock-up.
The user may return to the procedure upon recovery (i.e. it is not necessary to complete the entire sequence if operation is restored).
- 1. Enter the letter "E" AND press RETURN.
IF system accepts commands, THEN RETURN TO procedure.
- 2. Press "RESET" on terminal.
IF system accepts commands, THEN RETURN TO procedure.
- 3.
Enter "CNTL Y".
IF system accepts commands, THEN RETURN TO procedure.
- 4. Turn terminal power OFF and back ON again.
IF system accepts commands, THEN RETURN TO procedure.
- 5. Enter "CNTL Y".
IF system accepts commands, THEN RETURN TO procedure.
NOTE: The HP and CEOF terminals are normally connected to Server "A".
TSC and LEOF terminals are normally connected to Server "B".
- 6. Reset the MIDAS terminal servers as follows:
a)
Have all users attached to the server of interest exit MIDAS.
b)
Unplug the power cord for the MIDAS server applicable to the terminal of interest (located in TSC Computer Room MIDAS Cabinet).
c)
Plug the power cord back in to the MIDAS terminal server.
d)
Wait for approximately 2 minutes while the server loads files from MIDAS and restarts operation.
MIDAS will be out of service on at least two terminals during this time.
e)
IF system accepts commands, THEN RETURN TO procedure.
__ 7.
Connect to backup (alternate) MIDAS system:
a)
Reset terminal by turning terminal power OFF and then back ON again.
b)
Press CTRL K keys.
c)
WHEN the "Local>" prompt appears, THEN type "C SMIDAS".
Make sure to put a space between "C" and "SMIDAS".
d)
RETURN TO procedure Step 2 and continue using manually entered monitor and meteorological data.
- 8. Notify MIDAS System Manager or Code Administrator and the RAD or RAC.
NUMBER ATTACHMENT TITLE REVISION EPIP-4.30 RESPONSE TO TERMINAL LOCK-UP 5
ATTACHMENT PAGE 1
1 of 1
- 1.
MAIN STEAM LINE BREAK:
"* Release duration:
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, with all activity released in first 1/2 hour.
"* Release from faulted line:
3.58E+5 lb-mass (0 to 1/2 hr).
"* Release from unaffected steam lines:
0-8 hours =
1.55E+5 lb-mass/hr per generator.
"* Primary and secondary side activity:
Technical Specification limits at onset of event.
"* Primary to secondary leak rate:
Technical Specification limit, 500 gpd in affected generator, and 1440 gpd (1 gpm) total for all 3 steam generators.
"* Iodine partition factors: Faulted S/G = 1: Intact S/Gs = 0.01.
"* Condenser is assumed unavailable and the following release points apply:
Broken steam line, intact steam line relief valves, and AFWPT.
"* Activity released from broken steam line is distributed among the other 3 remaining release paths:
2 intact reliefs and AFWPT.
"* Concurrent Iodine spike is 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> in duration.
"* 9.25% of total activity is released via AFWPT.
Steam flow to AFWPT:
40.5 lbs/hr per horsepower.
Rated power = 710 horsepower.
AFWPT total steam flow = 28,755 lbs/hr.
"* No fuel failure is assumed as a result of the MSLB event.
- 2.
STEAM GENERATOR TUBE RUPTURE:
- Release duration:
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, with all activity released in the first 1/2 hour.
0 Tubes in the affected steam generator are uncovered at 5 minutes from event initiation, and remain uncovered for 10 minutes.
a Iodine Partition Factor:
1.0 in affected steam generator; 0.01 in unaffected generators.
a The affected steam generator is assumed isolated within 30 minutes.
a Primary and secondary side activity:
Technical Specification limits at onset of event.
0 Primary to secondary leak rate:
Technical Specification limit, 500 gpd in affected enerator, and 1440 gpd (1 gpm) total for all 3 steam generators.
0 Primary coolant release to affected steam generator:
132,000 lbs (0-30 minutes).
0 Steam release from affected steam generator: 81,640 lbs from 0-30 minutes.
a Steam release from intact steam generators:
0-2 hours = 85,250 lb-mass/hr per generator: 2-8 hours = 50,417 lb-mass/hr per generator.
0 Condenser is assumed unavailable and the following release points apply:
faulted generator relief valves, intact steam line relief valves, AFWPT.
If the condenser is available, release points include:
Steam line relief valves (3),
- AFWPT, Vent Vent A (and air ejector).
- All activity released is distributed among the 3 main steam reliefs and AFWPT.
- Concurrent Iodine spike is 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> in duration.
- 2% of total activity is released via AFWPT.
Steam flow to AFWPT:
40.5 lbs/hr per horsepower.
Rated power = 710 horsepower.
AFWPT total steam flow = 28,755 lbs/hr.
- No fuel failure is assumed as a result of the SGTR event.
NUMBER ATTACHMENT TITLE REVISION EPIP-4.30 DESIGN BASIS ACCIDENT TECHNICAL OVERVIEW 5
ATTACHMENT PAGE 2
1 of 3
- 3.
FUEL HANDLING ACCIDENT (in Fuel Building):
"* Release duration assumed for 1/2 hour.
"* Fuel Pool effective Iodine partition factor of 0.01 (Decontamination
- Factor, DF, = 100).
"* Release is through the charcoal filtration system.
The filters through which the fuel building is exhausted are assumed to be 95% efficient for all species of Iodine.
"* Fuel is not moved until 150 hours0.00174 days <br />0.0417 hours <br />2.480159e-4 weeks <br />5.7075e-5 months <br /> post shutdown (= decay time).
- 4.
WASTE GAS DECAY TANK RUPTURE:
- Release duration assumed for 15 minutes.
- Entire contents of tank released (25,000 Ci D.E. Xe-133).
- 1/2 of release occurs via Process Vent.
- 1/2 of release occurs via Vent Vent B.
- 5.
LOSS OF COOLANT ACCIDENT - MELT:
"* Release duration: 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
"* Release paths:
Containment (Containment leakage) and Vent Vent B (ECCS leakage).
"* Containment airborne source term: 100% core Noble Gases, 25% core Iodines.
"* Spray removal: 10 hr-1 for elemental Iodine.
"* Containment leak rate: 0.1% per day, 0 to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> (1.3 cfm).
"* ECCS leakage: 0 to 10 min. = 50 gpm; 10 min. to 30 days = 900 cc/hour.
"* Iodine released in building atmosphere from ECCS leakage: 10%.
"* Filter efficiency for safeguards exhaust: 90% elemental Iodine.
- 6.
LOSS OF COOLANT ACCIDENT -
PC:
"* RCS concentration assumed at Technical Specification limits.
"* Safeguards filter efficiency: 90% elemental Iodine.
"* Release duration: 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
- 7.
LOSS OF COOLANT ACCIDENT -
GAP:
- 3% core Noble Gases and 2% core lodines assumed in gap.
Safeguards filter efficiency: 90% elemental Iodine.
- Release duration: 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
- 8.
LOCKED ROTOR:
"* Fuel cladding failure is assumed at 5%.
"* Total release duration: 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.
"* Condenser is assumed available.
An Iodine Partition Factor of 0.01 is assumed for the condenser.
"* Steam flow to AFWPT = 40.5 lbs/hr per horsepower.
Rated power = 710 horsepower.
AFWPT steam flow = 28,755 lbs/hr.
"* No iodine spike is assumed.
"* Normal feedwater is not available.
"* No steam generator tube uncovery is assumed.
NUMBER ATTACHMENT TITLE REVISION EPIP-4.30 DESIGN BASIS ACCIDENT TECHNICAL OVERVIEW 5
ATTACHMENT PAGE 2
2 of 3
- 9.
MISCELLANEOUS GENERAL ASSUMPTIONS:
"* Vent Vent A:
Auxiliary Building, Air Ejector(s).
"* Vent Vent B:
Safeguards (filtered),
Fuel Building (filtered),
Containment Purge (filtered), Waste Gas Decay Tank area.
"* Process Vent: Waste Gas Decay Tanks, Containment Vacuum.
"* Containment leakage:
MIDAS uses the higher of the two CHRRMS monitors to calculate the release.
"* Air Ejector Monitors:
MIDAS adds the Air Ejector release to the associated vent vent release.
"* Main Steam and AFWPT:
MIDAS adds the flows from each "open" and "status unknown" valve to calculate the total flow for a particular steam line.
MIDAS sums the releases from all three steam lines and AFWPT to calculate the total release.
"* For Vent Vents and Process Vents, MIDAS uses the highest radiation monitor indication on the affected pathway to calculate dose projections.
"* For "Quick Dose" defaults:
Unidentified mix, ground level, all release points active, and noble gas and iodine.
"* NAPS DEFAULT FLOW RATES:
PATHWAY FLOW RATE VENT VENT A:
Flow as indicated by FR-HV-1212A (for VG-104, VG-174.
VG-179)
ERFCS unknown/bad data: 0 scfm MIDAS default: 1.42 E+5 scfm VENT VENT B:
Flow as indicated by FR-HV-12128 (for VG-113.
VG-175, VG-180)
ERFCS unknown/bad data: 0 scfm MIDAS default: 1.0 E+5 scfm PROCESS VENT:
Flow indicated by FT-GW-108 (for GW-178, GW-102)
ERFCS unknown/bad data: 0 scfm MIDAS default flow: 310 scfm AIR EJECTOR:
TV-SV-102-2 (-202-2) open:
25 scfm TV-SV-102-2 (-202-2) closed:
0 scfm TV-SV-102-2 (-202-2)
ERFCS unknown/bad data:
25 scfm MIDAS default: 25 scfm CONTAINMENT:
Containment pressure < 14.7 psia: 0 scfm Containment pressure > 14.7 psia: 1.33 scfm ERFCS unknown/bad data: 0 scfm MIDAS default: 1.30 scfm MAIN STEAM:
The flow for all valves associated with a specific line are summed to determine the release rate associated with the radiation monitor for that pathway.
SAFETY VALVES:
Valve open or ERFCS unknown/bad data: 855.084 lb-mass/hr Valve closed: 0 ATMOSPHERIC RELIEFS: Valve open or ERFCS unknown/bad data: 425.244 lb-mass/hr Valve closed: 0 DECAY HEAT RELEASE:
Valve open or ERFCS unknown/bad data: 60,333 lb-mass/hr/generatorl MIDAS DEFAULT TOTAL: 4.27 E+6 lbs-mass/hr per steam line AFWPT:
Flow indicated by FT-MS-107 (-207)
ERFCS unknown/bad data: 0 MIDAS default: 3.7 E+5 lb-mass/hr NUMBER ATTACHMENT TITLE REVISION EPIP-4.30 DESIGN BASIS ACCIDENT TECHNICAL OVERVIEW 5
ATTACHMENT PAGE 2
3 of 3