DATE: 03/11/02 PAGE: 141 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 258 000 A C S I -2 0 02 -34 C -F -I Elbow to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

2 5 81 0 0 2H -1 9 F -A V T -3 Rigid Support F1.20A GANGED WITH 2H-19A (7/00)

I-----------------------

258300 AC-06-SI-2002-35 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

I-------------------------------------------------

258400 AC-06-SI-2002-36 C-F-I X

Elbow to Tee C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

258500 AC-06-SI-2002-37 C-F-I X

Tee to Pipe C5.llA Category and item number will be R-A and RI.20 for the 4th interval.

258700 AC-06-SI-2002-38 C-F-I Pipe to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

258800 2H-20A F-A VT-3 X

Rigid Support FI.20A 259100 2H-21 F-A VT-3 Spring Hanger Fl.20C 25 93 0 0 A C SI -2 002 -39 C -F -i X

Pipe to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

259400 AC-06-SI-2002-40 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.


------------------------------------------------------------------- I------------------

DATE: 03/11/02 PAGE: 142 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 259600 AC-06-SI-2002-41 C-F-I Pipe to Valve SI-857A C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

259700 Valve SI-857A 6" Valve No examination required 259800 AC-06-SI-2002-42 C-F-I Tee to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

259900 AC-06-SI-2002-43 C-F-I Elbow to Pipe CS.IIA Category and item number will be R-A and Rl.20 for the 4th interval.

260100 AC-06-SI-2002-44 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

260200 AC-06-SI-2002-45 C-F-I Elbow to Pipe CS.IIA Category and item number will be R-A and R1.20 for the 4th interval.

260400 AC-06-SI-2002-46 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

260500 2H-29 F-A VT-3 Spring Support Fl.20C 260700 AC-06-SI-2002-47 C-F-i Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

260800 AC-06-SI-2002-48 C-F-I Pipe to Valve SI-871A C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 143 POINT BEACH NUCLEAR PLANT UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 260900 Valve SI-871A 6" Valve No examination required 261000 AC-06-SI-2002-49 C-F-I Valve SI-871A to Tee C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I----------

RHR to B Safety Injection Pump Suction

/

Dwg.

No.

ISI-PRI-2234 262000 22-2H-16B F-A VT-3 X

X Rigid Support Fl.20A GANGED WITH 2H-16B, SI-301R-1

2H14A, AND AN UNIDENTIFIED 2" PIPE (7/00) 262200 22-2H-16A F-A VT-3 Rigid Support Fl.20B GANGED WITH 2H-16A, SI-301R-1 2H13A AND AN UNKNOWN 2"

PIPE (7/00) 262400 AC-06-SI-2003-17 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

262500 AC-06-SI-2003-18 C-F-I Elbow to Pipe CS.IIA Category and item number will be R-A and Ri.20 for the 4th interval.

262800 2H-17A F-A VT-3 Rigid Support FI.20A GANGED WITH 2H-17A (7/00) 262900 AC-06-SI-2003-18A C-F-i Pipe to Pipe C5.I1A Category and item number will be R-A and Rl.20 for the 4th interval.

263200 2H -18A F-A VT -3 Rigid Support Fl.20B I......-.......

I--------------

263500 AC-06-SI-2003-19 C-F-i X

Pipe to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

I----------------------------------------------------------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 263600 AC-06-SI-2003-20 Elbow to Pipe CATEGORY NDE ITEM NO METH C-F-I C5.

IA FIRST SECC PERIOD PERI OUT 1

2 3

4 1

2 ND THIRD OD PERIOD AGE 3

4 1

2 34 X

Category and item 263700 2H-19A Rigid Support number will be R-A and Rl.20 for the 4th interval.

F-A VT-3 Fl.20A GANGED WITH 2H-19 (7/00) 263900 AC-06-SI-2003-21 C-F-I Pipe to Elbow C5.11A X

Category and item number will be R-A and Rl.20 for the 4th interval.

264000 AC-06-SI-2003-22 C-F-i X

Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

264100 AC-06-SI-2003-23 Pipe to Tee C-F-I C5. 11A Category and item number will be R-A and Rl.20 for the 4th interval.

264200 AC-06-SI-2003-24 Tee to Pipe C-F-I C5. I1A Category and item number will be R-A and R1.20 for the 4th interval.

264400 2H-20 F-A VT-3 Rigid Support FI.20A 264700 AC-06-SI-2003-25 C-F-I Pipe to Elbow CS.11A Category and item number will be R-A and R1.20 for the 4th interval.

264800 2H-22 F-A VT-3 X

Spring Hanger Fl.20C 265000 AC-06-SI-2003-26 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

PAGE: 144

DATE: 03/11/02 PAGE: 145 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 265200 AC-06-SI-2003-27 C-F-P Pipe to Valve SI-857B C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

2 65300 V alv e SI-857B 6"

Valve No examination required No 265400 AC-06-SI-2003-28 C-F-i Tee to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

2 6 5 6 0 0 A C - 0 6 - S I - 2 0 0 3 - 2 9 C - F - I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

2 6 5 7 0 0 A C - 0 6 - S I - 2 0 0 3 - 3 0 C - F - I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

265900 AC-06-SI-2003-31 C-F-I X

Pipe to Elbow CS.IIA Category and item number will be R-A and R1.20 for the 4th interval.

266000 2H-30 F-A VT-3 X

Spring Support F1.20C 2 6 6 2 0 0 A C - 0 6 - S I - 2 0 0 3 - 3 2 C - F -

I X

Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I..............-----------I---------------------------- ----------------

266300 AC-06-SI-2003-33 C-F-I Pipe to Valve SI-871B C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

~~~~~~------

I---------------

266400 Valve S5-871B 6" Valve No examination required S--------------------

I

DATE: 03/11/02 PAGE: 146 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 266500 AC-06-SI-2003-34 C-F-I Valve SI-871B to Tee C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

RHER to Safety Injection Pump Suction / Dwg.

No. ISI-PRI-2235 267000 AC-06-SI-2003-01 C-F-I Reducer to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

RHR to B Safety Injection Pump Suction / Dwg.

No.

ISI-PRI-2235 267100 AC-06-SI-2003-02 C-F-I Pipe to Elbow C5.llA Category and item number will be R-A and R1.20 for the 4th interval.

267200 2H-14 F-A VT-3 X

Spring Hanger Fl.20C 267400 AC-06-SI-2003-03 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

267500 AC-06-SI-2003-04 C-F-i Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

267600 AC-06-SI-2003-05 C-F-i Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

267700 AC-06-SI-2003-06 C-F-i Pipe to Elbow CS.lIA Category and item number will be R-A and RI.20 for the 4th interval.

267800 AC-06-SI-2003-07 C-F-I Elbow to Pipe CS.IIA Category and item number will be R-A and RI.20 for the 4th interval.

DATE: 03/11/02 PAGE: 147 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 267900 AC-06-SI-2003-07A C-F-i Pipe to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

2 6 8 0 0 0 A C - 0 6 - S I - 2 0 0 3 - 0 8 C - F -i Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

2 6 8 2 0 0 A C - 0 6 - S I - 2 0 0 3 - 0 9 C - F - I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

2 6 83 0 0 A C -0 6 -S I -2 0 03 -

I0 C -F -I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

268400 AC-06-SI-2003-II C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I----------------

268500 R-2376A F-A VT-3 Rigid Support Fl.20B I-------------.....---------------------------------------------------------------------------------------------------- -------------

2 6 8 6 0 0 R - 2 3 7 5 A F - A V T -3 Rigid Support FI.20B 268700 R-2315A F-A VT-3 Rigid Support FI.20B GANGED WITH SI-30iR-I-R2315 AND R-2315A (7/00) 268800 AC-06-SI-2003-12 C-F-I Pipe to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

268900 AC-06-SI-2003-13 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

NUMBER EXAMINATION AREA IDENTIFICATION 269000 AC-06-SI-2003-14 Elbow to Pipe Category and item 269100 AC-06-SI-2003-15 Pipe to Elbow CATEGORY NDE ITEM NO METH C-F-I C5.1IA FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND THIRD PERIOD PERIOD OUTAGE 1 23 4

1 2

34 number will be R-A and R1.20 for the 4th interval.

C-F-I C5. IIA Category and item number will be R-A and R1.20 for the 4th interval.

269200 AC-06-SI-2003-16 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

Safety Injection Pump A Inlet and Outlet / Dwg.

No. ISI-PRI-2238 270000 SIS-06-SI-2005-01 Valve SI-896A to Pipe C-F-I C5.IIA Category and item number will be R-A and RI.20 270100 S-742A F-A Rigid Support FI.20B GANGED WITH S-742B 270200 SIS-06-SI-2005-02 C-F-i Pipe to Elbow C5.11A for the 4th interval.

VT-3 Category and item number will be R-A and RI.20 for the 4th interval.

270300 SIS-06-SI-2005-03 C-F-i Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 270400 2-2H3 F-A VT-3 Spring Support 270600 SIS-06-SI-2005-04 Pipe to Tee 4th interval.

Fl.20C C-F-I C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

270700 SIS-06-SI-2005-05 C-F-I Valve SI-857A to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

PAGE: 14 8

DATE: 03/11/02 PAGE: 149 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD SUM24ARY EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 270800 SIS-06-SI-2005-06 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

270900 SIS-06-SI-2005-07 C-F-I Elbow to Tee C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

271000 SIS-06-SI-2005-08 C-F-i Tee to Elbow C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

271100 SIS-06-SI-2005-09 C-F-i Elbow to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

271200 SIS-06-SI-2005-l0 C-F-I Pipe to Flange C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

271300 Safety Injection Pump P-15A Safety Injection Pump No examination required 271400 SIS-06-SI-2005-12 C-F-I SUR Flange to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I------------------------------------------------------------------------

271500 SIS-06-SI-2005-13 C-F-1 SUR Elbow to Reducer C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

271600 SIS-06-SI-2005-14 C-F-I SUR Reducer to Pipe C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and RI.20 for the 4th interval.

271700 SIS-06-SI-2005-14-BC C-F-i SUR 2" Branch Connection C5.41 Category and item number will be R-A and RI.20 for the 4th interval.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFI CATION SIS-06-SI-2005-15 Pipe to Valve SI-889A CATEGORY NDE ITEM NO METH C-F-I SUR C5.11 VOL PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 34 1

23 4

Cal Block:

52-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

271900 Valve SI-889A 6"

Valve No examination required 272000 SIS-06-SI-2005-16 C-F-1 SUR Valve SI-889A to Elbow C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

272100 SIS-06-SI-2005-17 C-F-l SUR X

Elbow to Pipe C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

272200 S-250 F-A VT-3 Rigid Support Fl.20B 272300 SIS-06-SI-2005-18 C-F-I Pipe to Elbow C5.11 Cal Block:

52-PTB Category and item number will be R-A and R1.20 272400 SIS-06-SI-2005-19 C-F-l Elbow to Valve SI-888A C5.11 SUR VOL X

for the 4th interval.

SUR VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

272500 Valve SI-888A 6" Valve No examination required 272600 SIS-06-SI-2005-20 Valve SI-888A to Elbow Cal Block:

52-PTB C-F-I SUR C5.11 VOL Category and item number will be R-A and R1.20 for the 4th interval.

272700 1-2H2 F-A VT-3 Spring Hanger FI.20C

SUMMARY

NUMBER 271800 THIRD PERIOD 1

2 3

4 X

PAGE: 150

DATE: 03/11/02 PAGE: 151 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 CQMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 272900 SIS-06-SI-2005-21 C-F-I SUR X

Elbow to Tee C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

273000 SIS-06-SI-2005-21A C-F-l SUR Tee to Valve SI-829A C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

273100 Valve SI-829A 6"

Valve No examination required I-------------------------------------------------------

273200 SIS-06-SI-2005-22 C-F-l SUR Tee to Reducer C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

Safety Injection Pump B Inlet and Outlet

/

Dwg.

No.

ISI-PRI-2239 274100 SIS-06-SI-2006-01 C-F-l Valve SI-896B to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

274200 S-742B F-A VT-3 Rigid Support Fl.20B GANGED WITH S-742A 274300 SIS-06-SI-2006-02 C-F-l Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

274400 SIS-06-SI-2006-03 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

274500 SIS-06-SI-2006-04 C-F-I Pipe to Tee C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I--------I---------------------------------------------------------------------

274600 SIS-06-SI-2006-05 C-F-I Tee to Valve SI-857B C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I----------

I......

I-----..

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 274700 SIS-06-SI-2006-06 Tee to Pipe FIRST PERIOD CATEGORY NDE ITEM NO METH 1

2 3

4 C-F-I C5.

IA PLAN STATUS SECOND PERIOD OUTAGE 1

2 3

4 1

2 3

4 Category and item number will be R-A and Rl.20 274800 SIS-06-SI-2006-07 C-F-i Pipe to Flange CS.llA for the 4th interval.

Category and item number will be R-A and Rl.20 for the 4th interval.

274900 Safety Injection Pump P-15B Safety Injection Pump No examination required 275000 SIS-06-SI-2006-08 C-F-I SUR Flange to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

275100 SIS-06-SI-2006-09 Elbow to Reducer C-F-I SUR C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 275200 SIS-06-SI-2006-I0 C-F-I SUR Reducer to Pipe C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

275300 SIS-06-SI-2006-10-BC 2" Branch Connection C-F-I C5.41 SUR Category and item number will be R-A and R1.20 for the 4th interval.

275500 SIS-06-SI-2006-II C-F-I SUR Pipe to Valve SI-889B C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

275600 Valve SI-889B 6" Valve No examination required 275700 SIS-06-SI-2006-12 C-F-I SUR Valve SI-889B to Elbow C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

THIRD PERIOD 4th interval.

PAGE: 152

PAGE: 153 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 275800 SIS-06-SI-2006-13 C-F-I SUR Elbow to Pipe C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

275900 1-2H3 F-A VT-3 Spring Hanger FI.20C 276100 SIS-06-SI-2006-14 C-F-I SUR Pipe to Elbow C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

276200 SIS-06-SI-2006-15 C-F-I SUR Elbow to Valve SI-888B C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

-I----------------------------

276300 Valve SI-888B 6" Valve No examination required 276400 SIS-06-SI-2006-16 C-F-I SUR Valve SI-888B to Elbow C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

276500 1-2H4 F-A VT-3 Spring Hanger FI.20C 276700 SIS-06-SI-2006-17 C-F-I SUR Elbow to Tee C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and R1.20 for the 4th interval.

276800 SIS-06-SI-2006-17A C-F-I SUR Tee to Pipe C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and Ri.20 for the 4th interval.

I..........I-------------------------

276900 SIS-06-SI-2006-17B C-F-I SUR Pipe to Valve SI-829B C5.11 VOL Cal Block:

52-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION CATEGORY NDE ITEM NO METH PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 34 1

2 34 277000 Valve SI-829B 6"

Valve No examination required S

.....\\...................................................

277100 SIS-06-SI-2006-18 Tee to Reducer Cal Block:

52-PTB C-F-I SUR X

CS. 11 VOL Category and item number will be R-A and R1.20 for the 4th interval.

RHR to Reactor Pressure Vessel / Dwg.

No.

ISI-PRI-2240 278000 SIS-06-SI-2007-01 Tee to Pipe C-F-I C5. 11A Category and item number will be R-A and R1.20 for the 4th interval.

278100 SIS-06-SI-2007-02 C-F-I Pipe to Elbow C5. 11A Category and item number will be R-A and RE.20 for the 4th interval.

278200 SIS-06-SI-2007-03 C-F-I Elbow to Valve SI-852A C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

278300 Valve SI-852A 6"

Valve No examination required 278400 SIS-06-SI-2007-04 Valve SI-852A to Pipe C-F-I SUR C5.11 VOL Cal Block:

4-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

278500 2R-24 F-A VT-3 Rigid Support FI.20B 278600 SIS-06-SI-2007-05 Pipe to Valve SI-853A Cal Block:

4-PTB C-F-I SUR C5.11 VOL Category and item number will be R-A and RI.20 for the 4th interval.

SUMMARY

NUMBER THIRD PERIOD 1

2 3

4 PAGE: 154

PAGE: 155 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 2

3 4

1 2

3 4

1 2

34 RHR to RPV Injection / Dwg.

No.

ISI-PRI-2241 279000 SIS-06-SI-2008-01 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and Ri.20 for the 4th interval.

279200 SIS-06-SI-2008-02 C-F -

I Pipe to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

279300 SIS-06-SI-2008-03 C-F-I Elbow to Pipe C5.ilA Category and item number will be R-A and R1.20 for the 4th interval.

I----------------------------------

279400 SIS-06-SI-2008-04 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

279500 SIS-06-SI-2008-05 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

279600 H201 F-A VT-3 Rigid Support FI.20C I....

279800 SIS-06-SI-2008-06 C-F-i Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

-- --- ----------------- I--------------------------------------------------------------

279900 SI-601R-2-H5 F-A VT-3 Spring Hanger FI.20C


----------- -------------------.........----------------------- --------- -----------I- --------------------

280100 SIS-06-SI-2008-07 C-F-Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

280200 H200 F-A VT-3 Component Support FI.20A

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION SIS-06-SI-2008-08 Pipe to Elbow CATEGORY NDE ITEM NO METH C-F-I C5.

IA PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD OUTAGE 1

2 34 1

234 1

23 4

Category and item number will be R-A and Rl.20 S

280500 SIS-06-SI-2008-09 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and Rl.20 280600 SI-601R-2-H4 F-A Spring Hanger Fi.20C 280800 R-2372 Component Support 280900 SIS-06-SI-2008-10 Pipe to Elbow F-A F1.20A for the 4th interval.

for the 4th interval.

VT-3 X

VT-3 C-F-i CS. 11A Category and item number will be R-A and RI.20 281000 SIS-06-SI-2008-1i C-F-i Elbow to Pipe C5.11A for the 4th interval.

Category and item number will be R-A and R1.20 for the 281200 SI-601R-2-H3 F-A VT-3 Spring Hanger FI.20C 281400 SIS-06-SI-2008-12 C-F-i Pipe to Elbow C5.11A 4th interval.

Category and item number will be R-A and R1.20 for the 4th interval.

281500 SIS-06-SI-2008-13 Elbow to Pipe C-F-i C5. llA Category and item number will be R-A and R1.20 for the 4th interval.

281600 R-2334 F-A VT-3 X

Rigid Support FI.20B

SUMMARY

NUMBER 280400 PAGE: 156

DATE: 03/11/02 PAGE: 157 POINT BEACH NUCLEAR PLANT UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 281700 SIS-06-SI-2008-14 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I--------------

I------------------------.....I------ --------------------- --- --- ----------

281800 SIS-06-SI-2008-15 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

281900 SI=601R-2-H2 F-A VT-3 Rigid Support FI.20C I..--------------------------------------

282100 SIS-06-SI-2008-16 C-F-i Pipe to Flange C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

282200 SIS-06-SI-2008-17 C-F-I Flange to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

282300 SI-601R-2-Hl F-A VT-3 Rigid Support Fl.20B 282400 SIS-06-SI-2008-18 C-F-I Pipe to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

I---------------

282500 SIS-06-SI-2008-18A C-F-I Pipe to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I-------

RHR to RPV Injection / Dwg.

No.

ISI-PRI-2242 283000 SIS-06-SI-2008-19 C-F-1 Pipe to Penetration C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

INACCESSIBLE DUE TO PENETRATION CONFIGURATION.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 283100 A-1l/M82 Anchor CATEGORY NDE ITEM NO METH F-A VT-3 Fl.20E FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 34 X

PENETRATION 22 283110 SIS-06-SI-2008-20 Penetration to Pipe C-F-I C5. 11A Category and item number will be R-A and R1.20 for the 4th interval.

283300 SIS-06-SI-2008-21 C-F-I Pipe to Elbow CS. 11A Category and item number will be R-A and R1.20 for the 4th interval.

283400 R-96 F-A VT-3 Rigid Support Fl.20A NOTED ON WE-200072 AS A WHIP RESTRAINT 283500 SIS-06-SI-2008-22 Elbow to Pipe C-F-I C5. 11A Category and item number will be R-A and R1.20 for the 4th interval.

283600 SIS-06-SI-2008-23 C-F-i Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

283700 SIS-06-SI-2008-24 Elbow to Pipe C-F-I C5. 11A Category and item number will be R-A and RI.20 for the 4th interval.

283800 R-94 F-A VT-3 Rigid Support 283900 SIS-06-SI-2008-25 Pipe to Valve SI-852B FI.20B C-F-i CS.

1A Category and item number will be R-A and RI.20 for the 4th interval.

284000 Valve SI-852B 6" Valve No examination required THIRD PERIOD 1

2 3

4 PAGE: 158

PAGE: 159 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS FIRST PERIOD PLAN STATUS SECOND PERIOD fl TI '1 A n E

SUMMARY

EXAMINATION AREA UATEGOR

  • 4 NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 284100 SIS-06-SI-2008-26 C-F-I SUR Valve SI-852B to Pipe C5.11 VOL Cal Block:

4-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

284200 R-93 F-A VT -3 Rigid Support FI.20B THIRD PERIOD 1

2 34 284300 SIs-06-SI-2008-27 C-F-I SUR Pipe to Valve SI-853B C5.11 VOL Cal Block:

4-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

Loop A Main Steam Inside Containment / Dwg.

No. ISI-PRI-2243 285000 MS-31-MS-2001-01A C-F-2 SUR Nozzle to Pipe C5.51 VOL Cal Block:

44-PTB Category and item number will be R-A and R1.20 for the 4th interval.

One longitudinal seam weld on the downstream side.

285010 MS-31-MS-2001-01ALD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

1 1-------------------------------------

285090 MS-31-MS-2001-01BLU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

285100 MS-31-MS-2001-01B C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

44-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

One longitudinal seam weld on the upstream side and two on the downstream side.

285110 MS-31-MS-2001-01LDI C-F-2 SUR Inside Downstream Long weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

285120 MS-31-MS-2001-01LDO C-F-2 SUR Outside Downstream Long Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY ITEM NO NDE METH PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 34 1

23 4

285180 MS-31-MS-2001-02LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

285190 MS-31-MS-2001-02LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.


I------------------------


..... ------- I-----------------

I-----------------------------------

285200 MS-31-MS-2001-02 C-F-2 SUR X

Elbow to Pipe C5.51 VOL Cal Block:

44-PTB Category and item number will be R-A and R1.20 for the 4th interval.

Two longitudinal seam welds on the upstream side and one on the downstream side.

285210 MS-31-MS-2001-02LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

285290 MS-30-MS-2001-02ELU Upstream Long Weld Cal Block:

45-PTB Component will be deleted from 285300 MS-30-MS-2001-02E Pipe to Pipe C-F-2 SUR C5.52 VOL the fourth interval ISI Program.

C-F-2 SUR C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and R1.20 for the 4th interval.

on the upstream side and one on the downstream side.

285310 MS-30-MS-2001-02ELD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

285390 MS-30-MS-2001-02HLU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB One longitudinal seam weld Component will be deleted from the fourth interval ISI Program.

I------------

I----------------------------------

285400 MS-30-MS-2001-02H C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and R1.20 for the 4th interval.

One longitudinal seam weld on the upstream side and one on the downstream side.

THIRD PERIOD 1

2 3

4 PAGE: 160

PAGE: 161 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 285410 MS-30-MS-2001-02HLD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

285500 HS-32 F-A VT-3 Snubber FI.20S Ganged with HS-33 285600 HS-33 F-A VT-3 Snubber F1.20S Ganged with HS-32 285690 MS-30-MS-2001-03LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

285700 MS-30-MS-2001-03 C-F-2 SUR Pipe to Flow Element C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and R1.20 for the 4th interval.

One longitudinal seam weld on the upstream side and one on the downstream side.

I-------------------------------------


--------------------- I------------

285710 MS-30-MS-2001-03LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.


I------------------------------------------------------------------------------------------------------------------------- ------ ---------

285790 MS-30-MS-2001-04LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

285800 MS-30-MS-2001-04 C-F-2 SUTR Flow Element to Elbow C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and RI.20 for the 4th interval.

One longitudinal seam weld on the upstream side and two on the downstream side.

285810 MS-30-MS-2001-04LDI C-F-2 SUR Inside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

285820 MS-30-MS-2001-04LDO C-F-2 SUR Outside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY ITEM NO NDE METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 34 285880 MS-30-MS-2001-05LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

285890 MS-30-MS-2001-05LU0 C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

285900 MS-30-MS-2001-05 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and R1.20 for the 4th interval.

on the upstream side and one on the downstream side.

285910 MS-30-MS-2001-05LD Downstream Longitudinal Weld Cal Block:

45-PTB Two longitudinal seam welds C-F-2 SUR C5.52 VOL Component will be deleted from the fourth interval ISI Program.

286100 MS-2H3 F-A VT-3 Spring Hanger Fl.20C Ganged with R-10 286390 MS-30-MS-2001-06LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

286400 MS-30-MS-2001-06 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

One longitudinal seam weld on the upstream side and one on the downstream side.

286410 MS-30-MS-2001-06LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

286500 MS-2H4 F-A VT-3 Constant Support Fl.20C Ganged with R-13, 286990 MS-30-MS-2001-07LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

THIRD PERIOD 1

2 3

4 PAGE: 162

DATE: 03/11/02 PAGE: 163 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 287000 MS-30-MS-2001-07 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and R1.20 for the 4th interval.

One longitudinal seam weld on the upstream side and one on the downstream side.


..... I- ------------- --------------------------------------------------------------------------------------------------

287010 MS-30-MS-2001-07LD C-F-2 SUR Downstream Longitudinal weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

-.. I------------------------------------------------------------------------------------------------------------- ----------------------------

287090 MS-30-MS-2001-07ALU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

S---------------------------------------------------------------------------------------------------------------------------

287100 MS-30-MS-2001-07A C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and RI.20 for the 4th interval.

One longitudinal seam weld on the upstream side and one on the downstream side.

287110 MS-30-MS-200!-07ALD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.


----- I---------------

287200 MS-2RI6 F-A VT-3 Rigid Support FI.20A Ganged with MD-2H5, MOD 96-026 I----------------------------------------------------

287300 MS-2H5 F-A VT-3 X

Spring Hanger Fl.20C Ganged with R-16 Loop A Main Steam Inside Containment /

Dwg. No.

ISI-PRI-2244 287990 MS-30-MS-2001-08LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

288000 MS-30-MS-2001-08 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

One longitudinal seam weld on the upstream side and one on the downstream side.

1............ I---------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY ITEM NO NDE METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND THIRD PERIOD PERIOD OUTAGE 1

23 4

1 234 288010 MS-30-MS-2001-08LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

288200 MS-2H6 F-A VT-3 Spring Hanger FI.20C Ganged with R-19 288490 MS-30-MS-2001-09LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

288500 MS-30-MS-2001-09 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

on the upstream side and one on the downstream side.

288510 MS-30-MS-2001-09LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

288790 MS-30-MS-2001-10LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI 288800 MS-30-MS-2001-10 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

45-PTB One longitudinal seam weld Program.

Category and item number will be R-A and R1.20 for the 4th interval.

One longitudinal seam weld on the upstream side and one on the downstream side.

288810 MS-30-MS-2001-10LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

288900 MS-2H7 F-A VT-3 Spring Hanger Fl.20C Ganged with R-22 289090 MS-30-MS-2001-11LU Upstream Long Weld C-F-2 SUR C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

PAGE: 164

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS FIRST PERIOD PLAN STATUS SECOND PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G a NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 289100 MS-30-MS-2001-11 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and RI.20 for the 4th interval.

One longitu on the upstream side and one on the downstream side.

S---------------------

289110 MS-30-MS-2001-11LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

I-----------------------------------------------------

289300 MS-30-MS-2001-11-BC C-F-2 SUR 6" Branch Connection C5.81 Category and item number will be 290000 MS-06-MS-2001-01 Branch Connection to Pipe Category and item number will be 290100 MS-06-MS-2001-02 Pipe to Cap THIRD PERIOD 1

2 34 dinal seam weld R-A and R1.20 for the 4th interval.

C-F-2 C5.5lA R-A and R1.20 for the 4th interval.

C-F-2 C5.51A Category and item number will be R-A and Rl.20 for the 4th interval.

SI Loop B Main Steam Inside Containment /

Dwg. No. ISI-PRI-2245 291000 MS-31-MS-2002-01A Nozzle to Pipe Cal Block:

44-PTB C-F-2 SUR C5.51 VOL Category and item number will be R-A and R1.20 for the 4th interval.

One longitudinal seam weld on the downstream side.

291010 MS-31-MS-2002-01ALD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

1----------------------------------------------------------------------------------------

291090 MS-31-MS-2002-01BLU C-F-2 SUR E.

Upstream Long Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

291100 MS-31-MS-2002-01B C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

44-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

One longitudinal seam weld on the upstream side and two on the downstream side.

PAGE: 165 L----

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION MS-31-MS-2002-01LDI Inside Downstream Long Weld CATEGORY ITEM NO C-F-2 C5.52 NDE METH SUR VOL PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

23 4

1 23 4

Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

291120 MS-31-MS-2002-01LDO C-F-2 SUR Outside Downstream Long Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

291180 MS-31-MS-2002-02LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

291190 MS-31-MS-2002-02LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

291200 MS-31-MS-2002-02 C-F-2 SUR Elbow to Pipe C5.51 VOL X

Cal Block:

44-PTB Category and item number will be R-A and R1.20 for the 4th interval.

Two longitudinal seam welds on the upstream side and one on the downstream side.

291210 MS-31-MS-2002-02LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

291290 MS-31-MS-2002-02ELU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

291300 MS-31-MS-2002-02E C-F-2 SUR Pipe to Pipe C5.51 VOL X

Cal Block:

44-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

One longitudinal seam weld on the upstream side and one on the downstream side.

291310 MS-31-MS-2002-02ELD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

291390 MS-31-MS-2002-02HLU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

SUMMARY

NUMBER 291110 THIRD PERIOD 1

2 3

4 PAGE: 166

DATE: 03/11/02 PAGE: 167 POINT BEACH NUCLEAR PLANT

- UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 291400 MS-31-MS-2002-02H C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

44-PTB Category and item number will be R-A and R1.20 for the 4th interval.

One longitudinal seam weld on the upstream side and one on the downstream side.

I---------------------------------------------------

I----------------------

291410 MS-31-MS-2002-02HLD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

44-PTB Component will be deleted from the fourth interval ISI Program.

291500 HS-34 F-A VT-3 Snubber FI.20S Ganged with HS-35 and MS-2HI.

291600 HS-35 F-A VT-3 Snubber F1.20S Ganged with HS-34 and MS-2HI.

291800 MS-2H1 F-A VT-3 Spring Hanger FI.20C Ganged with HS-34 and HS-35 291890 MS-31-MS-2002-03LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

....... I -------------------------------------------------------------- ----------- ---------------------

291900 MS-31-MS-2002-03 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

44-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

One longitudinal seam weld on the upstream side and two on the downstream side.

291910 MS-31-MS-2002-03LDI C-F-2 SIR Inside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

291920 MS-31-MS-2002-03LDO C-F-2 SUR Outside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

291980 MS-30-MS-2002-04LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION CATEGORY ITEM NO NDE METH PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

23 4

1 23 4

291990 MS-30-MS-2002-04LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

292000 MS-30-MS-2002-04 C-F-2 SUR Elbow to Pipe CS.51 VOL Cal Block:

46-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

on the upstream side and one on the downstream side.

292010 MS-30-MS-2002-04LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

292190 MS-30-MS-2002-05LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

292200 MS-30-MS-2002-05 C-F-2 SUR Pipe to Flow Element C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

on the upstream side and two on the downstream side.

292210 MS-30-MS-2002-05LD Downstream Longitudinal Weld Cal Block:

45-PTB C-F-2 C5.52 Two longitudinal seam welds X

One longitudinal seam weld SUR VOL Component will be deleted from the fourth interval ISI Program.

292290 MS-30-MS-2002-06LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

292300 MS-30-MS-2002-06 C-F-2 SUR Flow Element to Elbow C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

One longitudinal seam weld on the upstream side and two on the downstream side.

292310 MS-30-MS-2002-06LDI C-F-2 SUR Inside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

SUMMARY

NUMBER THIRD PERIOD 1

2 3

4 PAGE: 168

PAGE: 169 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION MS-30-MS-2002-06LDO Outside Downstream Long Weld CATEGORY ITEM NO C-F-2 C5.52 NDE METH SUR VOL PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD OUTAGE 1

2 3

4 1

2 3

4 1

2 3

4 Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

292400 MS-2H2 F-A VT-3 Constant Support Fl.20C Ganged with EB-l-R3 and EB-l-R4 292500 MS-2H2-IWA C-C SUR X

Welded Attachment C3.20 Category and item number will be R-A and Rl.20 for the 4th interval 292680 MS-30-MS-2002-07LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.


~~~~----------------------------------------------------------

292690 MS-30-MS-2002-07LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

292700 MS-30-MS-2002-07 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

on the upstream side and one on the downstream side.

292710 MS-30-MS-2002-07LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

292890 MS-30-MS-2002-08LU C-F-2 SUR Upstream Long Weld C5.52 VOL Two longitudinal seam welds Cal Block:

45-PTB Component will be deleted from the fourth interval IS1 Program.

292900 MS-30-MS-2002-08 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and RI.20 for the 4th interval.

One longitudinal seam weld on the upstream side and two on the downstream side.

I.....

292910 MS-30-MS-2002-08LDI C-F-2 SUR Inside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

SUMMARY

NUMBER 292320

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION CATEGORY ITEM NO NDE METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD 0 u T A G E 1

2 3

4 292920 MS-30-MS-2002-08LDO C-F-2 SUR Outside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

292980 MS-30-MS-2002-09LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

292990 MS-30-MS-2002-09LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

293000 MS-30-MS-2002-09 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

on the upstream side and one on the downstream side.

293010 MS-30-MS-2002-09LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

Loop A Main Steam Outside Containment / Dwg.

No.

ISI-PRI-2246 Two longitudinal seam welds 293990 MS-30-MS-2001-18LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

294000 MS-30-MS-2001-18 C-F-2 SUR Pipe to Tee C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

on the upstream side and two on the downstream side.

294010 MS-30-MS-2001-18LDI C-F-2 SUR Inside Downstream Long Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

X One longitudinal seam weld 294020 MS-30-MS-2001-18LDO C-F-2 SURE-Outside Downstream Long Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

SUMMARY

NUMBER THIRD PERIOD 1

2 34 PAGE: 170

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 294080 MS-30-MS-2001-19L CATEGORY ITEM NO C-F-2 C5.52

'U' Inside Upstream Long Weld NDE METH SUR VOL FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1 2 34 Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

294090 MS-30-MS-2001-19LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

294100 MS-30-MS-2001-19 C-F-2 SUR X

Tee to Valve MS-2018 C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

Two longitudinal seam welds on the upstream side.

on

--- --------~~~~~~~~~~~~------------

I---

I-------

294200 Valve MS-2018 30" Valve No examination required.

Bolting 2" or less in size.

294300 MS-30-MS-2001-20 C-F-2A VOL Valve MS-2018 to Elbow MEB 3-1 Cal Block:

46-PTB Two longitudinal seam welds on the downstream side.

I ---

294310 MS-30-MS-2001-20LDI Inside Downstream Long Weld Cal Block:

46-PTB 294320 MS-30-MS-2001-20LDO Outside Downstream Long Weld Cal Block:

46-PTB 294380 MS-30-MS-2001-21LUI Inside Upstream Long Weld Cal Block:

46-PTB 294390 MS-30-MS-2001-21LUO Outside Upstream Longitudinal Cal Block:

46-PTB 294400 MS-30-MS-2001-21 Elbow to Pipe Cal Block:

46-PTB C-F-2A VOL MEB 3-1 C-F-2A VOL MEB 3-1 C-F-2A VOL MEB 3-1 C-F-2A Weld MEB 3-1 VOL C-F-2A VOL MEB 3-1 TWo longitudinal seam welds on the upstream side and one on the downstream side.

.............I - - - - -- - - - - - - - -- - - -

PAGE: 171 THIRD PERIOD 1

2 3

4

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION MS-30-MS-2001-21LD Downstream Longitudinal Weld Cal Block:

46-PTB CATEGORY ITEM NO C-F-2A MEB 3-1 NDE METH VOL PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

23 4

1 23 4

294500 2H-19B Rigid Support F-A Fl.20C VT-3 SHOWN AS A SPRING HANGER ON P-207, BASED ON P-407 SH18 IT IS A RIGID SUPPORT (8/00) 294690 MS-30-MS-2001-22LU C-F-2A VOL Upstream Long Weld MEB 3-1 Cal Block:

46-PTB 294700 MS-30-MS-2001-22 C-F-2A VOL Pipe to Pipe MEB 3-1 Cal Block:

46-PTB One longitudinal seam weld on the upstream side and one on the downstream side.

294710 MS-30-MS-2001-22LD C-F-2A VOL Downstream Longitudinal Weld MEB 3-1 Cal Block:

46-PTB 294790 MS-30-MS-2001-23LU Upstream Long Weld Cal Block:

46-PTB C-F-2A VOL MEB 3-1 294800 MS-30-MS-2001-23 Pipe to Pipe Cal Block:

46-PTB One longitudinal seam weld on 294810 MS-30-MS-2001-23LD Downstream Longitudinal Weld Cal Block:

46-PTB C-F-2A MEB 3-1 VOL the upstream side and C-F-2A VOL MEB 3-1 one on the downstream side.

294890 MS-30-MS-2001-24LU Upstream Long Weld Cal Block:

46-PTB 294900 MS-30-MS-2001-24 Pipe to Pipe Cal Block:

46-PTB One longitudinal seam weld on the upstream side and one on the downstream side.

SUMMARY

NUMBER 294410 THIRD PERIOD 1

2 3

4 C-F-2A MEB 3-1 C-F-2A MEB 3-1 VOL VOL PAGE: 172

PAGE: 173 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION MS-30-MS-2001-24LD Downstream Longitudinal Weld Cal Block:

46-PTB CATEGORY ITEM NO C-F-2A MEB 3-1 NDE METH VOL FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 34 295000 R-250 F-A VT-3 Rigid Support FI.20A WE-200098 REFERENCED C-2390 AND C-396 (8/00)

I----------------------------

I----------------------------....

295980 MS-30-MSR-2001-01LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

47-PTB Component will be deleted from the fourth interval ISI Program.

295990 MS-30-MSR-2001-01LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

47-PTB Component will be deleted from the fourth interval ISI Program.

296000 MS-30-MSR-2001-01 C-F-2 SUR Tee to Pipe C5.51 VOL Cal Block:

47-PTB Category and item number will be R-A and R1.20 for the 4th interval.

Two longitudinal seam welds on the upstream side and one on the downstream side.


I-----

I---------

I-------------------------------------------------------------------------------

296010 MS-30-MSR-2001-01LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

47-PTB Component will be deleted from the fourth interval ISI Program.


Iý---------

296100 MS-30-MSR-2001-02-BC C-F-2 SUR E.

8" Branch Connection C5.81 Category and item number will be R-A and R1.20 for the 4th interval.

I--------------------------------------------------------------------------

296200 2H-20B F-A VT-3 Rigid Support FI.20A I------------------------------------------------------

296300 MS-30-MSR-2001-03-BC C-F-2 SUR E

8" Branch Connection C5.81 Category and item number will be R-A and RI.20 for the 4th interval.

296400 2H-20C F-A VT-3 X

Rigid Support FI.20A SHOWN AS A RESTRAINT ON P-207 (8/00)

SUMMARY

NUMBER 294910 THIRD PERIOD 1

2 3

4

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION CATEGORY ITEM NO C-F-2 C5.81 MS-30-MSR-2001-04-BC 8"

Branch Connection NDE METH SUR FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 34 Category and item number will be R-A and Rl.20 296600 MS-30-MSR-2001-05-BC C-F-2 8"

Branch Connection C5.81 for the 4th interval.

S UR Category and item number will be R-A and R1.20 for the 4th interval.

296700 2H-21A F-A VT-3 Rigid Support F1.20A SHOWN AS A RESTRAINT ON P-207 (8/00) 296800 MS-30-MSR-2001-06-BC 6"

Branch Connection C-F-2 S UR C5.81 Category and item number will be R-A and R1.20 for the 296900 2HC F-A VT-3 Rigid Support Fl.20B SHOWN AS A RESTRAINT ON P-207 (8/00) 296990 MS-30-MSR-2001-07LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

47-PTB Component will be deleted from the fourth interval ISI 297000 MS-30-MSR-2001-07 C-F-2 SUR Pipe to Cap C5.51 VOL Cal Block:

47-PTB Category and item number will be R-A and R1.20 for the on the upstream side.

298000 MS-08-MSR-2001-01 C-F-2 SUR Branch Connection to Flange C5.51 VOL 4th interval.

X -

Program.

4th interval.

One longitudinal seam weld Category and item number will be R-A and R1.20 for the 4th interval.

.I...........

.I.....

298100 MS-08-MSR-2001-01-FB Flange Bolting No examination required.

Bolting is less than 2" diameter.

298200 MS-08-MSR-2001-02 C-F-2 SUR Flange to Valve MS-2010 C5.51 VOL Category and item number will be R-A and R1.20 for the 4th interval.

This is a 6" valve attached to an 8" flange.

SUMMARY

NUMBER 296500 THIRD PERIOD 1 2 3

4 PAGE: 174

DATE: 03/11/02 PAGE: 175 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 298300 Valve MS-2010 6" Valve No examination required.

Bolting 2" or less in size.

299000 MS-08-MSR-2002-01 C-F-2 SUR Branch Connection to Flange C5.51 VOL Category and item number will be R-A and Rl.20 for the 4th interval.

299100 MS-08-MSR-2002-01-FB Flange Bolting No examination required.

Bolting is less than 2" diameter.

299200 MS-08-MSR-2002-02 C-F-2 SUR Flange to Valve MS-2011 C5.51 VOL Category and item number will be R-A and R1.20 for the 4th interval.

This is a

6" valve attached to an 8" flange.

I-----11-----------------------------

299300 Valve MS-2011 6" Valve No examination required.

Bolting 2" or less in size.

I---------------------I-------------------------------------------------------------------------------------------------------------------

300000 MS-08-MSR-2003-01 C-F-2 SUR Branch Connection to Flange C5.51 VOL Category and item number will be R-A and Rl.20 for the 4th interval.

300100 MS-08-MSR-2003-01-FB Flange Bolting No examination required.

Bolting is less than 2" diameter.

300200 MS-08-MSR-2003-02 C-F-2 SUR Flange to Valve MS-20i2 C5.51 VOL Category and item number will be R-A and Rl.20 for the 4th interval.

This is a 6" valve attached to an 8" flange.

300300 Valve MS-2012 6" Valve No examination required.

Bolting 2" or less in size.

~~----

I----------------

........... I-----------

301000 MS-08-MSR-2004-01 C-F-2 SUR X

X Branch Connection to Flange C5.51 VOL Category and item number will be R-A and R1.20 for the 4th interval.

~~---------

I----------------------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY ITEM NO NDE METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

301100 MS-08-MSR-2004-01-FB Flange Bolting No examination required.

Bolting is less than 2" diameter.

301200 MS-08-MSR-2004-02 C-F-2 SUR X

Flange to Valve MS-2013 C5.51 VOL Category and item number will be R-A and Rl.20 for the 4th interval.

This is a 6" valve attached to an 8" flange.

301300 Valve MS-2013 6" Valve No examination required.

Bolting 2" or less in size.

302000 MS-06-MSR-2001-01 Branch Connection to Pipe C-F-2 C5.5 IA X

Category and item number will be R-A and R1.20 for the 4th interval.

302100 MS-06-MSR-2001-02 C-F-2 Pipe to Valve MS-227 C5.51A Category and item number will be R-A and R1.20 for the 4th interval.

302200 Valve MS-227 6" Valve No examination required'.

302300 MS-06-MSR-2001-03 Valve MS-227 to Pipe Bolting 2" or less in size.

C-F-2 C5.5 1A Category and item number will be R-A and R1.20 for the 4th interval.

302400 MS-06-MSR-2001-04RI C-F-2 Pipe to Valve MS-2016 C5.51A Category and item number will be R-A and Rl.20 for the 4th interval.

302500 Valve MS-2016 6"

Valve No examination required.

Bolting 2" or less in size.

THIRD PERIOD 1

2 3

4 PAGE: 17 6

DATE: 03/11/02 PAGE: 177 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 RHR to B Safety Injection Pump Suction / Dwg.

No.

ISI-PRI-2247 303200 AC-08-SI-2001-11A C-F-i Pipe to Tee C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

I----

303300 AC-08-SI-2001-11B C-F-I Pipe to Tee C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

303400 AC-08-SI-2001-13 C-F-I Elbow to Pipe CS.IIA Category and item number will be R-A and R1.20 for the 4th interval.


I----------------------------

1-------------------

303500 AC-08-SI-2001-14 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I-------------------------------------------------------

303600 AC-08-SI-2001-14A C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

303700 2H-13 F-A VT-3 Spring Hanger FI.20C 3 04 0 0 0 2H -13A F -A V T -3 Rigid Support Fl.20A 3041 00 A C SI -20 01 -15 C -F -i Pipe to Tee C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

304200 AC-08-SI-2001-16 C-F-I Tee to Reducer C5.lIA Category and item number will be R-A and R1.20 for the 4th interval.


--------- ------------------------------- I----------------------------------------

304300 AC-08-SI-2001-17 C-F-i Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.


------- I--------------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION AC-08-SI-2001-17R Pipe to Cap CATEGORY NDE ITEM NO METH PLAN STATUS FIRST SECOND PERIOD PERIOD "OUTAGE 1

23 4

1 23 4

C-F-I C5. IIA Category and item 305000 AC-08-SI-2002-01 Tee to Pipe Category and item 305100 AC-08-SI-2002-02 Pipe to Elbow Category and item 305200 AC-08-SI-2002-03 Elbow to Reducer number will be R-A and R1.20 for the 4th interval.

C-F-1 C5.11A number will be R-A and R1.20 for the 4th interval.

C-F-1 C5.

lA number will be R-A and R1.20 for the 4th interval.

C-F-I CS. IIA Category and item number will be R-A 306000 AC-06-SI-2006-01 Reducer to Pipe and R1.20 for the 4th interval.

C-F-I C5.

lA Category and item number will be R-A and Rl.20 306100 AC-601R-7-H303 Support 306200 AC-06-SI-2006-02 Pipe to Elbow F-A Fl.20B C-F-I CS. 11A for the 4th interval.

vT-3 Category and item number will be R-A and R1.20 for the 4th interval.

306300 AC-06-SI-2006-03 C-F-i Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

306400 AC-06-SI-2006-04 C-F-I Pipe to Valve 2RH-706B C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

306500 Valve 2RH-706B 6" Valve No examination required

SUMMARY

NUMBER 304400 THIRD PERIOD 1

2 34 PAGE: 178

DATE: 03/11/02 PAGE: 179 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 Loop B Main Steam Outside Containment / Dwg.

No. ISI-PRI-2248 306990 MS-30-MS-2002-17LU C-F-2 SUR Upstream Long Weld C5.52.

VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

3 0 7 0 0 0 M S - 3 0 -M S - 2 0 0 2 - 1 7 C - F - 2 S U R Pipe to Tee C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

One longitudinal seam weld on the upstream side and two on the downstream side.

307010 MS-30-MS-2002-17LDI C-F-2 SUR Inside Downstream Long Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

307020 MS-30-MS-2002-17LDO C-F-2 SUR Outside Downstream Long Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

307080 MS-30-MS-2002-18LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

307090 MS-30-MS-2002-18LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

307100 MS-30-MS-2002-18 C-F-2 SUR Tee to Valve MS-2017 C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

Two longitudinal seam welds on the upstream side.

307200 Valve MS-2017 30" Valve No examination required.

Bolting 2" or less in size.

307300 MS-30-MS-2002-19 C-F-2A VOL Valve MS-2017 to Pipe MEB 3-1 Cal Block:

46-PTB One longitudinal seam weld on the downstream side.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 307310 MS-30-MS-2002-19LD Downstream Longitudinal Weld Cal Block:

46-PTB CATEGORY ITEM NO C-F-2A MEB 3-1 NDE METH VOL PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD OUTAGE 1

23 4

12 34 1

2 34 307400 EB-I-2H8 Spring Support F-A VT-3 Fl.20C DUAL SPRING SUPPORT 307600 EB-l-2H7 F-A Rigid Support FI.20A NOT SHOWN ON P-207 (8/00) 307690 MS-30-MS-2002-20LU C-F-2A Upstream Long Weld MEB 3-1 Cal Block:

46-PTB VT-3 VOL 307700 MS-30-MS-2002-20 Pipe to Pipe Cal Block:

45-PTB One longitudinal seam weld on 307710 MS-30-MS-2002-20LD Downstream Longitudinal Weld Cal Block:

46-PTB 307800 EB-I-2H6 Rigid Support C-F-2A VOL MEB 3-1 the upstream side and one on the downstream side.

C-F-2A MEB 3-1 F-A F1.20A VOL VT-3 307980 MS-30-MSR-2002-01LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

47-PTB Component will be deleted from the fourth interval ISI Program.

307990 MS-30-MSR-2002-01LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

47-PTB Component will be deleted from the fourth interval ISI Program.

308000 MS-30-MSR-2002-01 C-F-2 SUR Tee to Pipe C5.51 VOL Cal Block:

47-PTB Category and item number will be R-A and R1.20 for the 4th interval.

Two longitudinal seam welds on the upstream side and one on the downstream side.

x PAGE: 180

DATE: 03/11/02 PAGE: 181 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 308010 MS-30-MSR-2002-01LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

47-PTB Component will be deleted from the fourth interval ISI Program.

308100 MS-30-MSR-2002-02-BC C-F-2 SUR 8" Branch Connection C5.81 Category and item number will be R-A and R1.20 for the 4th interval.

308200 EB-l-2H9 F-A VT-3 Rigid Support FI.20A 308300 MS-30-MSR-2002-03-BC C-F-2 SUR 8"

Branch Connection C5.81 Category and item number will be R-A and R1.20 for the 4th interval.

308400 EB-l-2H9A F-A VT-3 Rigid Support F1.20A SHOWN AS A RESTRAINT ON P-207 (8/00) 308500 MS-30-MSR-2002-04-BC C-F-2 SUR 8" Branch Connection C5.81 Category and item number will be R-A and Rl.20 for the 4th interval.

308600 MS-30-MSR-2002-05-BC C-F-2 SUR 8" Branch Connection C5.81 Category and item number will be R-A and R1.20 for the 4th interval.

308700 EB-l-2HI0 F-A VT-3 Rigid Support Fl.20A 308800 MS-30-MSR-2002-06-BC C-F-2 SUR 6" Branch Connection C5.81 Category and item number will be R-A and R1.20 for the 4th interval.

308900 EB-l-2HB F-A VT-3 Rigid Support Fl.20B SHOWN AS A RESTRAINT ON P-207 (8/00)

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY ITEM NO NDE METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

308990 MS-30-MSR-2002-07LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

47-PTB Component will be deleted from the fourth interval ISI Program.

309000 MS-30-MSR-2002-07 C-F-2 SUR Pipe to Cap C5.51 VOL Cal Block:

47-PTB Category and item number will be R-A and R1.20 for the 4th interval.

longitudinal seam weld on the upstream side.

310000 MS-08-MSR-2005-01 C-F-2 SIR Branch Connection to Flange C5.51 VOL Cap is 0.908 thick.

One Category and item number will be R-A and R1.20 for the 4th interval.

310100 MS-08-MSR-2005-01-FB Flange Bolting No examination required.

Bolting is less than 2" diameter.

310200 MS-08-MSR-2005-02 C-F-2 SUR Flange to Valve MS-2005 C5.51 VOL Category and item number will be R-A and Rl.20 for the 4th interval.

This is a 6" valve attached to an 8" flange.

310300 Valve MS-2005 6" Valve No examination required.

Bolting 2" or less 311000 MS-08-MSR-2006-01 C-F-2 Branch Connection to Flange C5.51 in size.

SUR VOL Category and item number will be R-A and R1.20 for the 4th interval.

311100 MS-08-MSR-2006-01-FB Flange Bolting No examination required.

Bolting is less than 2" diameter.

311200 MS-08-MSR-2006-02 C-F-2 SUR Flange to Valve MS-2006 C5.51 VOL Category and item number will be R-A and R1.20 for the 4th interval.

This is a

6" to an 8" flange.

THIRD PERIOD 1

2 3

4 valve attached PAGE: 182

DATE: 03/11/02 PAGE: 183 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 311300 Valve MS-2006 6"

Valve No examination required.

Bolting 2" or less in size.

312000 MS-08-MSR-2007-01 C-F-2 SUR Branch Connection to Flange C5.51 VOL Category and item number will be R-A and R1.20 for the 4th interval.

I---------------------

I------------------------

312100 MS-08-MSR-2007-01-FB Flange Bolting No examination required.

Bolting is less than 2" diameter.


I---------------------------------------------------------------------------------------

312200 MS-08-MSR-2007-02 C-F-2 SUR Flange to Valve MS-2007 C5.51 VOL Category and item number will be R-A and Rl.20 for the 4th interval.

This is a 6" valve attached to an 8" flange.

312300 Valve MS-2007 6" Valve No examination required.

Bolting 2" or less in size.

I--------------

313000 MS-08-MSR-2008-01 C-F-2 SUR Branch Connection to Flange C5.51 VOL Category and item number will be R-A and R1.20 for the 4th interval.

This weld will have an RT volumetric examination due to space limitations.

313100 MS-08-MSR-2008-01-FB Flange Bolting No examination required.

Bolting is less than 2" diameter.

313200 MS-08-MSR-2008-0 2

C-F-2 SUR Flange to Valve MS-2008 C5.51 VOL Category and item number will be R-A and R1.20 for the 4th interval.

This is a

6" valve attached to an 8" flange.

313300 Valve MS-2008 6"

Valve No examination required.

Bolting 2" or less in size.

POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 314000 MS-06-MSR-2002-01M C-F-2 Pipe to Pipe C5.51A Category and item number will be R-A and R1.20 for the 4th interval.

I..........................----- ------

314100 MS-06-MSR-2002-02RI C-F-2 Pipe to Valve MS-244 C5.51A Category and item number will be R-A and Rl.20 for the 4th interval.

314200 Valve MS-224 6" Valve No examination required.

Bolting 2" or less in size.

314300 MS-06-MSR-2002-03R I C-F-2 Valve MS-244 to Pipe C5.51A Category and item number will be R-A and R1.20 for the 4th interval.

314400 MS-06-MSR-2002-04 C-F-2 Pipe to Valve CV-2015 C5.51A Category and item number will be R-A and R1.20 for the 4th interval.

314500 Valve MS-2015 6"

Valve No examination required.

Bolting 2" or less in size.

Feedwater Loop A / Dwg.

No.

ISI-PRI-2249 315200 FW-16-FW-2001-O1ARI C-F-2A VOL-X Pipe to Valve CS-466AA MEB 3-1 Cal Block:

34-PTB 315400 FW-16-FW-2001-01RI C-F-2 SUR Valve CS-466AA to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

315500 2H-19C F-A VT-3 Spring Hanger F1.20C 315700 FW-16-FW-2001-02 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

DATE: 03/11/02 PAGE: 184

DATE: 03/11/02 PAGE: 185 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM No METH 1

2 3

4 1

2 3

4 1

2 3

4 315800 FW-16-FW-2001-03 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

315900 FW-16-FW-2001-04 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

316000 FW-16-FW-2001-05 C-F-2 SUR Pipe to Penetration C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

WELD ACCESS TO BE EVALUATED.

316100 A -04/M 83 F-A VT -3 Anchor FI.20B PENETRATION 4


-------- I-----------------------------

316110 FW-16-FW-2001-06 C-F-2 SUR Penetration to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

---I----------- ------- ---------------------

316200 FW-16-FW-2001-07 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

COMPONENT IS INACCESSIBLE.

316300 FW-16-FW-2001-08 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

316500 FW-16-FW-2001-09 C-F-2 SUR E.

Elbow to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

.............................I----------------------------

316600 R-13 F-A VT-3 Rigid Support FI.20A I------------------------------------------------......

316700 R-12 F-A VT-3 Rigid Support Fl.20A

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS FIRST PERIOD CATEGORY NDE

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 316800 FW-16-FW-2001-10 Pipe to Elbow Cal Block:

34-PTB ITEM NO C-F-2 CS.51 METH SUR VOL Category and item number will be R-A and R1.20 for the 4th 316900 FW-16-FW-2001-11 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

34-PTB PLAN STATUS SECOND THIRD PERIOD PERIOD OUTAGE 1

2 3

4 1

2 3

4 1

2 3

4 interval.

Category and item number will be R-A and R1.20 for the 4th interval.

Feedwater Loop A / Dwg.

No.

ISI-PRI-2250 318100 FW-16-FW-2001-12 Pipe to Elbow Cal Block:

34-PTB C-F-2 Cs.51 SUR VOL Category and item number will be R-A and Rl.20 318200 FW-16-FW-2001-13 C-F-2 Elbow to Pipe C5.51 Cal Block:

34-PTB for the 4th interval.

SUR VOL Category and item number will be R-A and R1.20 for the 4th interval.

318300 FW-2H6 F-A VT-3 Rigid Support F1.20B SHOWN AS A DUAL RESTRAINT ON P-212 (8/00) 318400 FW-16-FW-2001-14 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 318500 FW-2H5 F-A Rigid Support F1.20A 318600 FW-16-FW-2001-15 Pipe to Elbow C-F-2 C5.51 for the 4th interval.

VT-3 SUR VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

318700 FW-16-FW-2001-16 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A 318900 FW-16-FW-2001-17 Pipe to Elbow Cal Block:

34-PTB and R1.20 for the 4th interval.

C-F-2 SUR C5.51 VOL Category and item number will be R-A and RI.20 for the 4th interval.

PAGE: 186

PAGE: 187 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 319000 FW-16-FW-2001-18 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

319100 FW-2H4 F-A VT-3 X

Rigid Support Fl.20B 319200 FW-16-FW-2001-19 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

319300 FW-16-FW-2001-20 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I-----------------

319500 FW-2H3 F-A VT-3 Spring Hanger FI.20C


------ I-------------

319700 FW-16-FW-2001-21 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and RI.20 for the 4th interval.

3 19 800 FW FW -2 001 -22 C -F -2 SU R Elbow to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

320000 FW-16-FW-2001-23 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

320100 FW-16-FW-2001-24 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

320300 FW-16-FW-2001-24M C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

........................I------------------------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY ITEM NO NDE METH PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD OUTAGE 1234 1

234 1

234 320500 FW-16-FW-2001-25 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

320600 FW-2H2 F-A VT-3 Constant Support FI.20C 320800 FW-16-FW-2001-26 Elbow to Valve CS-466BB Cal Block:

34-PTB Category and item number 320900 Valve CS-466BB 16" Valve No examination required 321000 FW-16-FW-2001-27 Valve CS-466BB to Elbow Cal Block:

34-PTB Category and item number 321100 FW-2H1 Spring Hanger C-F-2 SUR C5.51 VOL will be R-A and R1.20 for the 4th interval.

C-F-2 C5.51 SUR VOL will be R-A and Rl.ll for the 4th interval.

F-A VT-3 Fl.20C 321300 FW-16-FW-2001-28 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.ll for the 4th interval.

321350 FW-16-FW-2001-28BC VT-3 3" Branch Connection Category and item number will be R-A 321400 FW-16-FW-2001-28D Pipe to Pipe Cal Block:

34-PTB Category and item number will be R-A 321500 FW-16-FW-2001-28G Pipe to Nozzle Cal Block:

34-PTB and R1.11 for the 4th interval.

C-F-2 SUR X

C5.51 VOL and R1.11 for the 4th interval.

C-F-2 C5.51 SUR VOL Category and item number will be R-A and Rl.ll/Rl.18 for the 4th interval.

X PAGE: 188

DATE: 03/11/02 PAGE: 189 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 Feedwater Loop B / Dwg.

No.

ISI-PRI-2251 322100 FW-16-FW-2002-OlARI C-F-2A VOL-X Pipe to Valve CS-476AA MEB 3-1 Cal Block:

34-PTB 322300 FW-16-FW-2002-OlR1 C-F-2 SUR Valve CS-476AA to Pipe CS.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

322400 2H-13B F-A VT-3 Dual Spring Hanger FI.20C 322600 FW-16-FW-2002-02 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and RI.20 for the 4th interval.

322700 FW-16-FW-2002-03 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

322800 FW-16-FW-2002-04 C-F-2 SUR Pipe to Penetration C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

FIELD ACCESS TO BE EVALUATED.

322900 FW-16-FW-2002-05 C-F-2 SUR Penetration to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

322910 A-03 F-A VT-3 Anchor Fl.20B 323000 FW-16-FW-2002-06 C-F-2 SUR Pipe to Elbow C5.Sl VOL Cal Block:

34-PTB Category and item number will be R-A and RI.18 for the 4th interval.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 323100 FW-16-FW-2002-07 Elbow to Pipe Cal Block:

34-PTB Category and item number will 323300 FW-16-FW-2002-08 Pipe to Elbow Cal Block:

34-PTB Category and item number will 323400 FW-16-FW-2002-09 Elbow to Pipe Cal Block:

34-PTB Category and item number will 323600 FW-16-FW-2002-10 Pipe to Elbow Cal Block:

34-PTB Category and item number will 323700 FW-16-FW-2002-11 Elbow to Pipe CATEGORY ITEM NO C-F-2 C5.51 be R-A and Rl.18 C-F-2 C5.51 be R-A and R1.20 C-F-2 C5.51 NDE METH SUR VOL PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 3

4 1

2 3

4 THIRD PERIOD 1

2 3

4 for the 4th interval.

SUR VOL for the 4th interval.

SUR VOL be R-A and Rl.20 for the 4th interval.

C-F-2 SUR C5.51 VOL be R-A and R1.20 C-F-2 C5.51 for the 4th SUR VOL interval.

Cal Block:

34-PTB Category and item number will be R-A and R1.20 323900 FW-2H9 F-A Spring Hanger F1.20C for the 4th interval.

Weld is inaccessible.

VT-3 Piping and structural steel in the area limits access, support is difficult to height.

324200 FW-16-FW-2002-12 C-F-2 SUR Pipe to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.20 for the 4th interval.

324400 FW-16-FW-2002-13 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and RI.20 324500 FW-16-FW-2002-14 C-F-2 Elbow to Pipe C5.51 Cal Block:

34-PTB Category and item number will be R-A and Rl.18 324700 FW-16-FW-2002-14M C-F-2 Pipe to Pipe C5.51 reach due to for the 4th interval.

SUR VOL for the 4th interval.

SUR VOL Cal Block:

34-PTB Category and item number will be R-A and R1.18 for the 4th interval.

PAGE: 190

PAGE: 191 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 324800 FW-16-FW-2002-l5 C-F-2 SUR E Pipe to Elbow C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and R1.18 for the 4th interval 325000 FW-2H8 F-A VT-3 Constant Support FI.20C 325200 FW-16-FW-2002-16 C-F-2 SUR Elbow to Valve CS-476BB C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.18 for the 4th interval.

325400 FW-16-FW-2002-17 C-F-2 SUR Valve CS-476BB to Elbow C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.ll/Rl.l8 for the 4th interval.

I--------------------------------------------- ----------------------

I 325600 FW-2H7 F-A VT-3 X

Spring Hanger FI.20C 325700 FW-16-FW-2002-18 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.ll/Rl.18 for the 4th interval.


I....-------- ----------

3 2 5 7 5 0 F W - 1 6 - F W - 2 0 0 2 - 1 8 B C S UR 3"

Branch Connection Category and item number will be R-A and Rl.11 for the 4th interval.

325800 FW-16-FW-2002-18D C-F-2 SUR X

Pipe to Pipe C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and RI.II/Rl.18 for the 4th interval.


I-----------

325900 FW-16-FW-2002-18G C-F-2 SURE X -

Pipe to Nozzle C5.51 VOL Cal Block:

34-PTB Category and item number will be R-A and Rl.II/Rl.18 for the 4th interval.

1

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS FIRST PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 RHR Pump A Suction from Cont Sump & Loop A Hot Leg / Dwg.

No.

ISI-PRI-2252 PLAN STATUS SECOND PERIOD OUTAGE 1

2 3

4 327100 Valve 2S1-850A 10" Valve Group 5 Valve.

327400 AC-10-RHR-2003-04 Valve 281-850A to Pipe Cal Block:

33-PTB C-G SUR C6.20 C-F-I SUR C5.11B VOL X

Category and item number will be R-A and R1.20 for the 4th interval.

327500 AC-10-RHR-2003-04A C-F-I SUR Pipe to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

327600 H-201 F-A VT-3 Rigid Support F1.20B 327700 AC-10-RHR-2003-05 C-F-I SUR Pipe to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

327800 AC-10-RHR-2003-06 C-F-I SUR Pipe to Elbow C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

327900 H-200A F-A VT-3 Rigid Support FI.20B 328000 AC-10-RHR-2003-07 Elbow to Valve SI-851A Cal Block:

33-PTB C-F-I SUR C5.11B VOL Category and item number will be R-A and R1.20 for the 4th interval.

328100 Valve SI-851A 10" Valve No examination required 328200 AC-10-RHR-2003-08 C-F-I SUR Valve SI-851A to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

THIRD PERIOD 1

2 3

4 PAGE: 192

DATE: 03/11/02 PAGE: 193 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 328300 2H-04A F-A VT-3 Spring Hanger FI.20C 328500 AC-10-RHR-2003-09 C-F-I SUR Pipe to Tee C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and RI.20 for the 4th interval.

329000 AC-10-RHR-2002-05 C-F-i SUR Pipe to Elbow C5.iIB VOL Cal Block:

33-PTB Category and item number will be R-A and Rl.20 for the 4th interval.


I-----------------------------------

329100 AC-10-RHR-2002-06 C-F-i SUR Elbow to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I----

329300 AC-10-RHR-2002-07 C-F-I SUR Pipe to Elbow C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

1------------------------------

329400 AC-10-RHR-2002-08 C-F-I SUR Elbow to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

329500 2H-04 F-A VT-3 Spring Hanger FI.20C 329700 AC-10-RHR-2002-09 C-F-I SUR Pipe to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

330000 AC-10-RHR-2002-10 C-F-i SUR Pipe to Elbow C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and RI.20 for the 4th interval.

I---------------------

I-------------------------------------------

330100 AC-10-RHR-2002-

!l C-F-i SUR Elbow to Tee C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION AC-10-RHR-2002-12 Tee to Pipe CATEGORY ITEM NO C-F-I C5. lB NDE METH SUR VOL FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

THIRD PERIOD 1

2 34 Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

330300 AC-10-RHR-2002-13 C-F-I SUR Pipe to Elbow C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

330400 AC-10-RHR-2002-14 C-F-I SUR Elbow to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 330500 AC-10-RHR-2002-15 C-F-I Pipe to Elbow C5.11B Cal Block:

33-PTB Category and item number will be R-A and R1.20 330600 AC-10-RHR-2002-16 C-F-I Elbow to Pipe C5.11B Cal Block:

33-PTB for the SUR VOL 4th interval.

for the 4th interval.

SUR VOL Category and item number will be R-A and R1.20 for the 4th interval.

330700 2H-03 F-A VT-3 Spring Hanger Fl.20C 330900 AC-10-RHR-2002-17 C-F-i SUR Pipe to Flange C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

331000 RHR Pump P-10A Pump No examination required RHR Pump B Suction from Cont Sump & Loop B Hot Leg / Dwg.

No.

ISI-PRI-2253 332100 Valve SI-850B 10" Valve C-G C6.20 SUR Examine valve body welds on only one of two valves, SI-850A or SI-850B..

332400 AC-10-RHR-2005-04 C-F-i Valve SI-850B to Pipe CS.IlB Cal Block:

33-PTB SUR VOL Category and item number will be R-A and R1.20 for the 4th interval.

SUMMARY

NUMBER 330200 PAGE: 194

DATE: 03/11/02 PAGE: 195 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 332500 AC-10-RHR-2005-04A C-F-I SUR Pipe to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

332600 AC-10-RHR-2005-05 C-F-I SUR Pipe to Pipe CS.llB VOL Cal Block:

33-PTB Category and item number will be R-A and RI.20 for the 4th interval.

332700 H-205 F-A VT-3 Rigid Support Fl.20B I--------------------------

I-----------------------------

332800 2H-03B F-A VT-3 Spring Hanger F1.20C NOT SHOWN I------------------

333000 AC-10-RHR-2005-06 C-F-I SUR Pipe to Elbow CS.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.


I---------

333100 AC-10-RHR-2005-07 C-F-I SUR Elbow to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and RI.20 for the 4th interval.

333200 AC-10-RHR-2005-08 C-F-l SUR Pipe to Elbow C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and RI.20 for the 4th interval.

333300 AC-10-RHR-2005-09 C-F-l SUR Elbow to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I----------------------------

333400 AC-10-RHR -2005-10 C-F-I SUR Pipe to Valve SI-851B C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I 333500 Valve SI-851B i0" Valve No examination required

...............------ I....I--------------------------------------------------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 333600 AC-10-RHR-2005-11 Valve SI-851B to Pipe Cal Block:

33-PTB Category and item number will be 333700 R-2347A Rigid Support 333800 MARKED AS A RESTRAINT ON P-232 2H-02B Spring Support 334100 AC-10-RHR-2005-12 Pipe to Elbow Cal Block:

33-PTB Category and item number will be R-A 334200 AC-10-RHR-2005-13 Elbow to Pipe Cal Block:

33-PTB Category and item number will be R-A 334400 AC-10-RHR-2005-14 Pipe to Elbow Cal Block:

33-PTB CATEGORY ITEM NO C-F-I C5.lIB NDE METH SUR VOL FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

R-A and R1.20 for the 4th interval.

F-A VT-3 Fl.20B F-A Fl.2 0C C-F-1 C5. liB and R1.20 C-F-i C5. lIB VT-3 SUR VOL for the 4th interval.

SUR VOL and R1.20 for the 4th interval.

C-F-i SUR C5.11B VOL Category and item number will be R-A and R1.20 334500 AC-10-RHR-2005-15 Elbow to Pipe Cal Block:

33-PTB C-F-l CS. l1B for the 4th interval.

SUR VOL Category and item number will be R-A and RI.20 for the 4th interval.

334700 AC-10-RHR-2005-16 C-F-I SUR Elbow to Tee C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

335000 AC-10-RHR-2004-05 C-F-I SUR Pipe to Elbow C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and RI.20 for the 4th interval.

335100 AC-10-RHR-2004-06 C-F-1 SUR Elbow to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and RI.20 for the 4th interval.

THIRD PERIOD 1

2 3

4 PAGE: 196

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION AC-10-RHR-2004-07 Pipe to Elbow CATEGORY NDE ITEM NO METH C-F-I SUR C5.11B VOL FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

S 335300 2H-01 F-A VT-3 Rigid Support Fl.20A 335500 AC-10-RHR-2004-08 C-F-I SUR Elbow to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

335600 AC-10-RHR-2004-09 C-F-I SUR Pipe to Tee C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

335700 AC-10-RHR-2004-10 C-F-I SUR Tee to Pipe C5.11B VOL Cal Block:

33-PTB Category and item number will be R-A and RI.20 335800 AC-10-RHR-2004-11 C-F-I Pipe to Flange C5.11B for the 4th interval.

SUR VOL Cal Block:

33-PTB Category and item number will be R-A and R1.20 for the 4th interval.

335900 RHR Pump P-10B Pump No examination required S------------------------------------------.........--------------------

Safety Injection Pump P-15A and P-15B Test Line / Dwg.

No.

ISI-PRI-2254 337000 SI-23 F-A VT-3 Rigid Support Fl.20B I...............-------------------------------

337100 SIS-02-SI-2008-24 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

I.....-----------------------------------------------

337200 SIS-02-SI-2008-25 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

SUMMARY

NUMBER 335200 PAGE: 197 THIRD PERIOD 1

2 3

4

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 337300 SIS-02-SI-2008-26 Pipe to Elbow CATEGORY ITEM NO C-F-I C5.30 NDE METH SUR PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 3

4 1

2 3

4 Category and item number will be R-A and Rl.20 337400 SIS-02-SI-2008-27 C-F-i Elbow to Pipe C5.30 for the 4th interval.

SUR Category and item number will be R-A and R1.20 for the 4th interval.

337500 SIS-02-SI-2008-28 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

337600 SIS-02-SI-2008-29 Elbow to Pipe C-F-1 C5.30 SUR Category and item number will be R-A and R1.20 337700 SIS-02-SI-2008-30 C-F-I Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 337800 SIS-02-SI-2008-31 C-F-I Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 337900 SI-24 F-A Rigid Support F1.20B 338000 SI-25 Rigid Support F-A Fl.2 338100 SIS-02-SI-2008-32 Pipe to Coupling for the 4th interval.

SUR for the 4th interval.

SUR for the 4th interval.

VT-3 VT-3 OB C-F-I C5.30 Category and item number will be R-A and Rl.20 338200 SIS-02-SI-2008-33 C-F-I Coupling to Pipe C5.30 SUR for the 4th interval.

SUR Category and item number will be R-A and R1.20 for the 4th interval.

THIRD PERIOD 1

2 34 PAGE: 198

DATE: 03/11/02 PAGE: 199 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 338300 SI-25A F-A VT-3 Rigid Support Fl.20B 338400 SIS-02-SI-2008-34 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

338500 SIS-02-SI-2008-35 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.---

338600 SI-26 F-A VT-3 Rigid Support FI.20B 338700 SIS-02-SI-2008-36 C-F-i SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

338800 SIS-02-SI-2008-37 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

338900 SI-27 F-A VT-3 Rigid Support FI.20A 339000 SIS-02-SI-2008-38 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

339100 SIS-02-SI-2008-39 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and Ra.20 for the 4th interval.

1..........

I---------------------------------------------

339200 SIS-02-SI-2008-40 C-F-i SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I------------------------------------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY NDE ITEM NO METH PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 3

4 1

2 3

4 1

2 3

4 339300 SIS-02-SI-2008-41 Elbow to Pipe Category and item number will be R-A and R1.20 for the 339400 SI-28 F-A VT-3 Rigid Support F1.20B 339500 SIS-02-SI-2008-42 Pipe to Tee 4th interval.

C-F-I SUR C5.30 Category and item number will be R-A and R1.20 for the 339600 SIS-02-SI-2008-45 C-F-I SUR Tee to Reducing Insert C5.30 Category and item number will be R-A and Rl.20 for the 339700 SIS-02-SI-2008-43 C-F-l SUR Tee to Pipe C5.30 4th interval.

4th interval.

Category and item number will be R-A and Rl.20 for the 4th interval.

339800 SI-29 Rigid Support 339900 SIS-02-SI-2008-44 Pipe to Valve SI-897B F-A VT-3 FI.20B C-F-1 SUR C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

340000 Valve SI-897B 2"

Valve No examination required Safety Injection Pump P-15B Test Line / Dwg.

No. ISI-PRI-2255 341000 SIS-02-SI-2008-01 Branch Connection to Pipe C-F-l C5.30 SUR Category and item number will be R-A and RI.20 for the 4th interval.

341100 SIS-02-SI-2008-02 C-F-i SUR Pipe to Elbow C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

C-F-I C5.30 SUR THIRD PERIOD PAGE: 200

PAGE: 201 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 341200 SIS-02-SI-2008-03 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

341300 SIS-02-SI-2008-04 C-F-i SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

341400 SIS-02-SI-2008-05 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

341500 SIS-02-SI-2008-06 C-F-I SUR Pipe to Coupling C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I---------------------------

341600 SIS-02-SI-2008-07 C-F-I SUR Coupling to Orifice C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I------------------------

I----------

341700 SIS-02-SI-2008-0 C-F-1 SUR Orifice to Coupling C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I---------------------------------------------------------

I----------------------------------

341800 SIS-02-SI-2008-09 C-F-I SUR Coupling to Pipe C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

341900 51-15 FAV Rigid Support Fl.20B 342000 SIS-02-SI-2008-i0 C-F-i SUE Pipe to Valve SI-891B C5.30 Category and item number will be R-A and R1.20 for the 4th interval 342100 Valve SI-891B 2"

Check Valve No examination required

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFI CATION SIS-02-SI-2008-11 Valve SI-891B to Pipe CATEGORY NDE ITEM NO METH C-F-I SUR CS.30 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

Category and item number 342300 SIS-02-SI-2008-12 Pipe to Valve SI-876B will be R-A and R1.20 for the 4th interval.

C-F-i SUR C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

342400 Valve SI-876B 2' Valve No examination required 342500 SIS-02-SI-2008-13 Valve SI-876B to Pipe Category and item number will 342600 SI-16 Rigid Support 342700 SIS-02-SI-2008-14 Pipe to Tee Category and item number will 342800 SIS-02-SI-2008-15 Tee to Pipe Category and item number will 342900 SIS-02-SI-2008-16 Pipe to Elbow C-F-I SUR C5.30 be R-A and R1.20 for the 4th interval.

F-A Fl.20B C-F-I VT-3 SUR C5.30 be R-A and R1.20 for the 4th interval.

C-F-I SUR C5.30 be R-A and R1.20 for the 4th interval.

C-F-I SUR C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

343000 SIS-02-SI-2008-17 Elbow to Pipe C-F-I C5.30 SUR Category and item number will be R-A and R1.20 for the 4th interval.

343100 SIS-02-SI-2008-18 C-F-I SURP Pipe to Elbow CS.30 Category and item number will be R-A and R1.20 for the 4th interval.

SUMMARY

NUMBER 342200 THIRD PERIOD 1

2 3

4 PAGE: 202

PAGE: 203 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 343200 SIS-02-SI-2008-19 C-F-i SUR Elbow to Pipe C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

343300 SI-17 F-A VT-3 Rigid Support FI.20A

............. I---------------,---------------------

343400 SI-18 F-A VT-3 Rigid Support Fl.20B I---------------------------------------------------------------------------------------

343500 SIS-02-SI-2008-20 C-F-I SUR Pipe to Tee C5.30 Category and item number will be R-A and RI.20 for the 4th interval.


I ---------

343600 SIS-02-SI-2008-21 C-F-I SUR Tee to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I-----------------

m----------------------------------------------

343700 SI-19 F-A VT-3 Rigid Support FI.20B 343800 SI-20 F-A VT-3 Rigid Support Fl.20B I-------------------------------------------------------------

343900 SI-21 F-A VT-3 0

Rigid Support FI.20B I-----------------------------------------------------------------------------

344000 SIS-02-SI-2008-22 C-F-I SUR Pipe to Coupling C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

344100 SIS-02-SI-200B-23 C-F-I SUR Coupling to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I----------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

NUMBER 344200 EXAMINATION AREA IDENTIFICATION SI-22 Rigid Support CATEGORY ITEM NO F-A FI.20B NDE METH VT-3 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 34 Safety Injection Pump P-15A Test Line / Dwg.

No.

ISI-PRI-2256 345000 SIS-02-SI-2007-01 Branch Connection to Pipe C-F-I CS.30 SUR Category and item number will be R-A and Rl.20 for the 4th interval.

345100 SIS-02-SI-2007-02 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 345200 SIS-02-SI-2007-03 C-F-I Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 345300 SIS-02-SI-2007-04 C-F-I Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 345400 SIS-02-SI-2007-05 C-F-I Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 345500 SI-34 F-A Rigid Support FI.20B 345600 SIS-02-SI-2007-06 Pipe to Coupling for the 4th interval.

SUE for the 4th interval.

SUR for the 4th interval.

SUR for the 4th interval.

VT-3 X

C-F-I SUR CS.30 Category and item number will be R-A and R1.20 for the 4th interval.

345700 SIS-02-SI-2007-07 C-F-1 SUR Coupling to Orifice C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

345800 SIS-02-SI-2007-08 C-F-I SUR Orifice to Coupling C5.30 Category and item number will be R-A and RP.20 for the 4th interval.

THIRD PERIOD 1 2 3

4 PAGE: 204

DATE: 03/11/02 PAGE: 205 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 345900 SIS-02-SI-2007-09 C-F-i SUR E.

Coupling to Pipe C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

I 346000 SI-05 F-A VT-3 X

Rigid Support FI.20A 346100 SIS-02-SI-2007-I0 C-F-I SUR E..

Pipe to Valve SI-891A C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

346200 Valve SI-891A 2"

Check Valve No examination required 34 6 3 00 SI S S I -2 0 07 -

I I C -F - I SU R E..

Valve SI-891A to Pipe C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

346400 SIS-02-SI-2007-12 C-F-I SUR Pipe to Valve SI-876A C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I-----

346500 Valve SI-876A 2" Valve No examination required 346600 SIS-02-SI-2007-13 C-F-I SUR E..

Valve SI-876A to Pipe C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

I---

346700 SIS-02-SI-2007-14 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I.............I--------------------------------------------------------------

346800 SIS-02-SI-2007-15 C-F-I SUR E..

Elbow to Pipe C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

PAGE: 206 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION SIS-02-SI-2007-16 Pipe to Elbow CATEGORY ITEM NO C-F-I C5.30 NUE METH SUR PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

23 4

1 23 4

THIRD PERIOD 1

2 34 Category and item number will be R-A and R1.20 for the 4th interval.

I....-------------

347000 SIS-02-SI-2007-17 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

347100 SI-10 F-A VT-3 Rigid Support FI.20A F-A 347200 SI-14 Rigid Support 347300 SIS-02-SI-2007-18 Pipe to Tee VT-3 FI.20B C-F-I SURP C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

Containment Spray Pumps P-14A and P-15A Test Line / Dwg.

No.

ISI-PRI-2257 348100 SIS-02-SI-2009-01 Valve SI-859B to Pipe C-F-I C5.30 SUR Category and item number will be R-A and Rl.20 for the 348200 SIS-02-SI-2009-02 C-F-I SPUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 348300 SIS-02-SI-2009-03 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 348400 SI-33A F-A VT-3 Rigid Support FI.20A 348500 SIS-02-SI-2009-04 Pipe to Tee C-F-I C5.30 4th interval.

4th interval.

4th interval.

SUR Category and item number will be R-A and R1.20 for the 4th interval.

SUMMARY

NUMBER 346900

DATE: 03/11/02 PAGE: 207 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 348600 SIS-02-SI-2009-05 C-F-I SUR Tee to Pipe C5.30 Category and item number will be R-A and Ri.20 for the 4th interval.


--------------------------------------------------------------------------------------------- I------------------------.......---------------------

348700 SIS-02-SI-2009-06 C-F-i SUR Pipe to Valve SI-873B C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

-- ------ I--------------------------------------------------------------------------- ---------------------------

348900 SIS-02-SI-2009-07 C-F-I SUR Valve SI-873B to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

349000 SIS-02-SI-2009-08 C-F-I SUR Pipe to Tee C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

349100 SIS-02-SI-2009-09 C-F-I SUR Tee to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I----I----I------------------------------------------------------------------------- ---------------------------------------------- ---------------

349200 SIS-02-SI-2009-10 C-F-i SUR Pipe to Tee C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

I------------------------------------------------------------------------

350100 SIS-02-SI-2009-II C-F-I SUR Valve SI-859A to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

350200 SIS-02-SI-2009-12 C-F-i SUR E.

Pipe to Elbow C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

350300 SIS-02-SI-2009-13 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

350400 SIS-02-SI-2009-14 C-F-I SUR Pipe to Tee C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

........................------------------------------------------- I-----------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

NUMBER EXAMINATION AREA IDENTIFICATION 350500 SIS-02-SI-2009-15 Tee to Pipe CATEGORY NDE ITEM NO METH C-F-i SUR C5.30 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 34 Category and item number will be R-A and R1.20 for the 4th interval.

350600 SIS-02-SI-2009-16 C-F-i SUR Pipe to Valve SI-873A C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

350800 SIS-02-SI-2009-17 C-F-i SUR Valve SI-873A to Pipe C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

350900 SIS-02-SI-2009-18 Pipe to Tee C-F-I C5.30 SUR Category and item number will be R-A and Rl.20 for the 4th interval.

351000 SIS-02-SI-2009-19 Tee to Pipe C-F-I C5.30 SUR Category and item number will be R-A and R1.20 for the 4th interval.

351200 SIS-02-SI-2009-20 Pipe to Tee C-F-I C5.30 SUR Category and item number will be R-A and R1.20 for the 352000 SIS-02-SI-2010-01 C-F-I SUR Tee to Pipe 4th interval.

C5.30 Category and item number will be R-A and R1.20 for the 352100 SIS-02-SI-2010-02 C-F-I SUR Pipe to Tee C5.30 4th interval.

Category and item number will be R-A and R1.20 for the 4th interval.

352200 SIS-02-SI-2010-03 Tee to Pipe C-F-I SUR C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

352300 SIS-02-SI-2010-04 Pipe to Elbow C-F-I SUR C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

THIRD PERIOD 1

2 3

4 PAGE: 208

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 352400 SIS-02-SI-2010-05 Elbow to Pipe CATEGORY NDE ITEM NO METH C-F-1 SUR C5.30 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

Category and item number will be R-A and Rl.20 for the 4th interval.

352500 SIS-02-SI-2010-06 Pipe to Elbow C-F-I SUR C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

352600 SIS-02-SI-2010-07 C-F-l SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

352700 SI-32 F-A VT-3 Rigid Support 352800 SI-33 X

FI.20B F-A VT-3 X

Rigid Support 352900 SIS-02-SI-2010-08 Pipe to Elbow Fl.20B C-F-I SUR C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

S I

353000 SIS-02-SI-2010-09 C-F-i SUR Elbow to Pipe CS.30 Category and item number will be R-A and R1.20 for the 4th interval.

353100 SIS-02-SI-2010-10 C-F-I SUR Pipe to Tee C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

354000 SIS-02-SI-2011-02 C-F-l SUR Reducing Insert to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

354100 SIS-02-SI-2011-03 C-F-l SUR Elbow to Pipe CS.30 Category and item number will be R-A and R1.20 for the 4th interval.

I------------------------------- -------

THIRD PERIOD 1

2 3

4 PAGE: 209

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION SIS-02-SI-2011-04 Pipe to Flange CATEGORY ITEM NO C-F-I C5.30 NDE METH SUR FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 34 Category and item 354500 SIS-02-SI-2011-05 Flange to Pipe number will be R-A and R1.20 for the 4th interval.

C-F-I SUR C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

354600 SI-30 F-A VT-3 Rigid Support Fl.20A 354700 SIS-02-SI-2011-06 Pipe to Elbow C-F-I SUR C5.30 Category and item number will be R-A and R1.20 for the 354800 SIS-02-SI-2011-07 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and RI.20 for the 354900 SI-31 F-A VT-3 Rigid Support F1.20B 355000 SIS-02-SI-2011-08 Pipe to Tee 4th interval.

4th interval.

C-F-I SUR C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

Core Deluge and Cold Leg Injection Header / Dwg.

No.

ISI-PRI-2258 356000 SIS-04-SI-2001-01 Reducer to Pipe Cal Block:

27-PTB C-F-I SUR C5.21 VOL Category and item number will be R-A and Ri.20 for the 4th interval.

356100 2H-01D F-A VT-3 X

Spring Hanger F1.20C GANGED WITH 2H-01E (7/00) 356300 SIS-04-SI-2001-02 Pipe to Elbow C-F-........ SUE ------------

C-F-1 SUR X

Cs. 21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

SUMMARY

NUMBER 354200 THIRD PERIOD 1

2 3

4 PAGE: 210

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2

COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY ITEM NO NDE METH PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

23 4

1 2

34

'I 356400 SIS-04-SI-2001-03 C-F-1 SUR.

Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

356500 SIS-04-SI-2001-04 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

356600 SIS-04-SI-2001-05 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I----------------------------------------------------

356700 SIS-04-SI-2001-06 C-F-I SUR B.

Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

356800 SIS-04-SI-2001-07 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

357000 SIS-04-SI-2002-01 C-F-i SUR Reducer to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

357100 2H-01E F-A VT-3

-X Spring Hanger FI.20C GANGED WITH 2H-01D (7/00) 357300 SIS-04-SI-2002-02 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

357400 SIS-04-SI-2002-03 C-F-I SUR B...-.-------

X-Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

357500 SIS-04-SI-2002-04 C-F-1 SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

PAGE: 211 THIRD PERIOD 1

2 3

4 X

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 357600 SIS-04-SI-2002-05 Elbow to Pipe Cal Block:

27-PTB CATEGORY ITEM NO C-F-I C5.21 NDE METH SUR VOL PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1 2 34 1

2 34 Category and item number will be R-A and Rl.20 for the 4th interval.

357700 2H-02C F-A VT-3 Rigid Support Fl.20A GANGED WITH l-2H2 357800 SIS-04-SI-2002-06 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

357900 SIS-04-SI-2002-07 C-F-1 SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

Core Deluge and Cold Leg Injection Header / Dwg.

No. ISI-PRI-2259 359000 SIS-04-SI-2001-08 C-F-I Pipe to Elbow C5.21 Cal Block:

27-PTB Category and item number will be R-A and R1.20 359100 SIS-04-SI-2001-09 C-F-I Elbow to Pipe C5.21 Cal Block:

27-PTB Category and item number will be R-A and R1.20 359200 H-202A F-A Rigid Support Fl.20A GANGED WITH H-202B (7/00) 359400 2H-03C Anchor F-A F1.20B GANGED WITH 2H-03D (7/00) 359500 SIS-04-SI-2001-10 C-F-I Pipe to Elbow CS.21 Cal Block:

27-PTB Category and item number will be R-A and R1.20 359600 SIS-04-SI-2001-11 C-F-I Elbow to Pipe C5.21 Cal Block:

27-PTB Category and item number will be R-A and R1.20 SUR VOL for the 4th interval.

SUR VOL for the 4th interval.

VT-3 VT-3 SUIR VOL for the 4th interval.

SUR VOL for the 4th interval.

THIRD PERIOD 1

2 3

4 PAGE: 212

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION H-207A Rigid Support CATEGORY ITEM NO F-A F1.20A NDE METH VT-3 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

GANGED WITH H-207B (7/00) 359800 H-206A Rigid Support GANGED WITH H-206B (7/00) 359900 SIS-04-SI-2001-12 Pipe to Pipe Cal Block:

27-PTB Category and item number 360000 H-205A Rigid Support F-A VT-3 Fl.20A C-F-l SUR CS.21 VOL will be R-A and Rl.20 for the 4th interval.

I....--

F-A VT-3 F1.20A GANGED WITH H-205B (7/00) 360100 H-204A F-A VT-3 Rigid Support Fl.20A GANGED WITH H-204B (7/00) 360200 SIS-04-SI-2001-13 Pipe to Pipe Cal Block:

27-PTB Category and item number will

-- ------------ I------------

360300 H-203A Rigid Support C-F-I C5.21 SUR VOL

  • be R-A and R1.20 for the F-A VT-3 F1.20B 4th interval.

GANGED WITH H-203B (7/00)

S 360400 S-852A FAV Rigid Support Fl.20B GANGED WITH S-852B (7/00) 360500 SIS-04-SI-2001-14 C-F-I SUR E.

X Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

360600 SIS-04-SI-2001-15 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

SUMMARY

NUMBER 359700 PAGE: 213 THIRD PERIOD 1

2 3

4

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION CATEGORY ITEM NO C-F-I C5.21 SIS-04-SI-2001-16 Pipe to Elbow NDE METH SUR VOL FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

Cal Block:

27-PTB Category and item number 360800 SIS-04-SI-2001-17 Elbow to Pipe Cal Block:

27-PTB will be R-A Category and item number will be 361000 SIS-04-SI-2002-08 Pipe to Elbow Cal Block:

27-PTB and Rl.20 for the 4th interval.

C-F-I SUR C5.21 VOL R-A and Rl.20 for the 4th interval.

C-F-I SUR C5.21 VOL Category and item number will be R-A and Rl.20 for the 4th interval.

361100 SIS-04-SI-2002-09 C-F-l SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

361200 H-202B Rigid Support GANGED WITH H-202A (7/00) 361300 2H-03D Anchor GANGED WITH 2H-03C (7/00) 361500 SIS-04-SI-2002-I0 Pipe to Elbow Cal Block:

27-PTB Category and item number will be R-A 361600 SIS-04-SI-2002-II Elbow to Pipe Cal Block:

27-PTB Category and item number will be R-A 361700 H-207B Rigid Support F-A VT-3 F1.20A F-A FI.20B C-F-I CS.21 and R1.20 C-F-I C5.21 and R1.20 F-A FI.20A VT-3 SUR VOL for the 4th interval.

SUR VOL for the 4th interval.

VT-3 GANGED WITH H-207A (7/00) 361800 H-206B Rigid Support GANGED WITH H-206A (7/00)

SUMMARY

NUMBER 360700 PAGE: 214 THIRD PERIOD 1

2 3

4 F-A Fl.20A VT -3

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION H-205B Rigid Support CATEGORY ITEM NO F-A Fl.20A NDE METH VT-3 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND THIRD PERIOD PERIOD OUTAGE 1

2 3

4 1

2 3

4 GANGED WITH H-205A (7/00)

I---------------------

362000 SIS-04-SI-2002-12 C-F-I SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I-----

362100 H-204B F-A VT-3 Rigid Support F1.20A GANGED WITH H-204A (7/00)

--I-------------------

362200 SIS-04-SI-2002-13 C-F-I SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I---------------------------------------------

362300 H-203B F-A VT-3 Rigid Support F1.20B GANGED WITH H-203A (7/00) 362400 S-852B F-A VT-3 Rigid Support F1.20B x

GANGED WITH S-852A (7/00) 362500 SIS-04-SI-2002-14 C-F-i SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

362600 SIS-04-SI-2002-15 C-F-I SUR X

Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

I------------------------------

362700 SIS-04-SI-2002-16 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

362800 SIS-04-SI-2002-17 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

SUMMARY

NUMBER 361900 PAGE: 215

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION Core Deluge and Cold Leg Injection Header /

CATEGORY NDE ITEM NO METH Dwa.

No. ISI-PRI-226 PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 34 1

23 4

0 363000 SIS-04-SI-2001-18 Pipe to Elbow Cal Block:

27-PTB Category and item number will be 363100 SIS-04-SI-2001-19 Elbow to Pipe Cal Block:

27-PTB Category and item number will be 363200 SIS-04-SI-2001-20 Pipe to Elbow C-F-I C5.21 SUR VOL R-A and R1.20 for the C-F-1 SUR C5.21 VOL R-A and R1.20 C-F-I C5.21 for the SUR VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

363300 SIS-04-SI-2001-21 C-F-i SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

363400 S-853A F-A VT-3 Rigid Support F1.20B GANGED WITH S-853B (7/00) 363500 SIS-04-SI-2001-22 Pipe to Pipe Cal Block:

27-PTB Category and item number will 363600 SIS-04-SI-2001-23 Pipe to Elbow Cal Block:

27-PTB Category and item number will 363700 SIS-04-SI-2001-24 Elbow to Pipe Cal Block:

27-PTB Category and item number will 363800 SIS-04-SI-2001-25 Pipe to Elbow Cal Block:

27-PTB Category and item number will 363900 SIS-04-SI-2001-26 Elbow to Pipe Cal Block:

27-PTB Category and item number will C-F-1 SUR C5.21 VOL be R-A and R1.20 C-F-1 C5.21 be R-A and R1.20 C-F-1 CS5.21 for the 4th interval.

SU--------------------------------------X SUR X

VOL for the 4th interval.

SUR VOL X

be R-A and R1.20 for the 4th interval.

C-F-1 SUR C5.21 VOL be R-A and Rl.20 for the 4th interval.

C-F-I SUR C5.21 VOL be R-A and R1.20 for the 4th interval.

THIRD PERIOD 1

2 3

4 4th interval.

4th interval.

X PAGE: 216

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION H-208A Rigid Support CATEGORY NDE ITEM NO METH F-A VT-3 Fl.20A PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 3

4 1

2 3

4 GANGED WITH H-208B (7/00) 364100 SIS-04-SI-2001-27 C-F-I SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

I-------

364200 S-854A F-A VT-3 Rigid Support FI.20B GANGED WITH S-854B (7/00)

I------I---


I--------------------------------------------

I---------------------------------------

364300 SIS-04-SI-2001-28 C-F-l SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 364400 SIS-04-SI-2001-29 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 364500 SIS-04-SI-2001-30 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB 4th interval.

4th interval.

Category and item number will be R-A and R1.20 for the 4th interval.

364600 SIS-04-SI-2001-31 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I...........I.....I..........---------------

365000 SIS-04-SI-2002-18 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will 365100 SIS-04-SI-2002-19 Elbow to Pipe Cal Block:

27-PTB Category and item number will 365200 SIS-04-SI-2002-20 Pipe to Elbow Cal Block:

27-PTB be R-A and Rl.20 C-F-I C5.21 be R-A and R1.20 C-F-I C5.21 for the 4th interval.

SUR VOL for the 4th interval.

SUR VOL Category and item number will be R-A and R1.20 for the 4th interval.


---------- I--------------

SUMMARY

NUMBER 364000 THIRD PERIOD 1

2 34 PAGE: 217

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS CATEGORY NDE

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 365300 SIS-04-SI-2002-21 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

365400 S-853B F-A VT-3 Rigid Support FI.20B GANGED WITH S-853A (7/00) 365500 SIS-04-SI-2002-22 C-F-I Pipe to Pipe C5.21 Cal Block:

27-PTB SUR VOL Category and item number will be R-A and R1.20 for the 365600 SIS-04-SI-2002-23 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 365700 SIS-04-SI-2002-24 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB 4th interval.

4th interval.

X X

Category and item number will be R-A and R1.20 for the 4th interval.

365800 H-208B F-A VT-3 Rigid Support Fl.20A GANGED WITH H-208A (7/00) 365900 SIS-04-SI-2002-25 C-F-i SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

366000 S-854B F-A VT-3 Rigid Support F1.20B GANGED WITH S-854A (7/00) 366100 SIS-04-SI-2002-26 C-F-i SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

366200 SIS-04-SI-2002-27 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

THIRD PERIOD PAGE: 218

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 366300 SIS-04-SI-2002-28 Pipe to Elbow Cal Block:

27-PTB CATEGORY ITEM NO C-F-I C5.21 NDE METH SUR VOL FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

THIRD PERIOD 1

2 3

4 Category and item number will be R-A and R1.20 for the 4th interval.


I--------------

I-------------------------------------------------

366400 SIS-04-SI-2002-29 C-F-l SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

S-----------------------------------------------

Core Deluge and Cold Leg Injection Header / Dwg. No. ISI-PRI-2261 367000 H-209A Rigid Support F-A FI.20A VT-3 GANGED WITH H-209B (7/00)

I--------

I------------------------------------------

I----------------------

367100 SIS-04-SI-2001-32 C-F-1 SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Rl.20 for the 4th interval.


----I--------------------------

367200 S-855A F-A VT-3 Rigid Support FI.20B SHOWN AS A RESTRAINT ON P-219 (8/00),

GANGED WITH S-855B 367300 H-210A F-A VT-3 Rigid Support Fl.20A GANGED WITH H-210B AND TWO UNIDENTIFIED PIPES (7/00) 367400 H-211A F-A VT-3 Rigid Support Fl.20A GANGED WITH H-211B AND TWO UNIDENTIFIED PIPES (7/00) 367500 SIS-04-SI-2001-33 C-F-l SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

367600 SIS-04-SI-2001-34 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.


.... I---------------------------------

I-----------------------

367700 SIS-04-SI-2001-35 C-F-l SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

I------------

PAGE: 219

POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4.1 2

3 4

1 2

3 4

367800 SIS-04-SI-2001-36 C-F-i SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

367900 SIS-04-SI-2001-37 C-F-l SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

368000 SIS-04-SI-2001-38 C-F-i SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

368100 H-08A F-A VT-3 Rigid Support FI.20A GANGED WITH H-08B (7/00) 369000 H-209B F-A VT-3 Rigid Support F1.20A GANGED WITH H-209A (7/00) 369100 SIS-04-SI-2002-30 C-F-I SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

369200 S-855B F-A VT-3 Rigid Support F1.20B SHOWN AS A RESTRAINT ON P-220 (8/00),

GANGED WITH S-855A 369300 H-210B F-A VT-3 Guide FI.20A GANGED WITH H-210A AND TWO UNIDENTIFIED PIPES (7/00) 369400 H-211B F-A VT-3 Rigid Support Fl.20A GANGED WITH H-211A AND TWO UNIDENTIFIED PIPES (7/00) 369500 SIS-04-SI-2002-31 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

DATE.

03/11/02 PAGE: 220

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS FIRST PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 369600 SIS-04-SI-2002-32 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

369700 SIS-04-SI-2002-33 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

Category and item number will be R-A and R1.20 for the 4th interval.

369800 SIS-04-SI-2002-34 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Ri.20 for the 4th interval.

369900 SIS-04-SI-2002-35 C-F-I SUR X

Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I-------------------------------------------

370000 SIS-04-SI-2002-36 C-F-I SUR X

Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

370100 H-08B F-A VT-3 X

Rigid Support Fl.20A GANGED WITH H-08A (7/00)

I Core Deluge and Cold Leg Injection Header / Dwg.

No. ISI-PRI-2262 371000 H-09A F-A VT-3 Rigid Support Fl.20A GANGED WITH H-09B (7/00) 371100 SIS-04-SI-2001-39 C-F-i SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

371200 S-856A F-A VT-3 X

Rigid Support FI.20A GANGED WITH S-856B (7/00) 371300 SIS-04-SI-2001-40 C-F-i SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

PAGE: 221 THIRD PERIOD 1

2 3

4

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 371400 SIS-04-SI-2001-41 Elbow to Pipe CATEGORY ITEM NO C-F-i C5.21 NDE METH SUR VOL FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

THIRD PERIOD 1

2 3

4 Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

371500 H-11 F-A VT-3 Rigid Support F1.20A 371600 H-I!A Rigid Support 371700 ADDED PER MOD 96-026 (8/00)

H-12 Rigid Support F-A Fl.20B F-A FI.20A VT-3 VT-3 371800 SIS-04-SI-2001-42 C-F-I SUR Pipe to Flange C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

371900 SIS-04-SI-2001-43 Flange to Pipe Cal Block:

27-PTB Category and item number will 372000 SIS-04-SI-2001-44 Pipe to Valve SI-866A Cal Block:

27-PTB Category and item number will 372100 Valve SI-866A 2" Valve No examination required 372200 SIS-04-SI-2001-45 Valve SI-866A to Pipe Cal Block:

27-PTB Category and item number will 372300 S-857A Rigid Support C-F-I SUR C5.21 VOL be R-A and R1.20 for the C-F-i SUR C5.21 VOL be R-A and R1.20 for the C-F-I CS.21 4th interval.

4th interval.

SUR VOL be R-A and RI.20 for the F-A VT-3 F1.20B 4th interval.

PAGE: 222

PAGE: 223 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 372400 SIS-04-SI-2001-46 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.


......... I---------------------------------------

372500 SIS-04-SI-2001-47 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I-------------------------------- --------- ----------------------------------------- ----------------------------------------- --------- I---------

372600 SIS-04-SI-2001-48 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

372700 SIS-04-SI-2001-4 9 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I-------------------------

I--------------------------------------------

372800 SIS-04-SI-2001-49A C-F-I SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

373000 H-09B F-A VT-3 Rigid Support Fl.20A GANGED WITH H-09A (7/00) 373100 SIS-04-SI-2002-37 C-F-i SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

I------------

373200 SIS-04-SI-2002-38 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

...-........................ I---------------

I--------------------------------------------------------------

373300 SIS-04-SI-2002-39 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

I-----------------

373400 SIS-04-SI-2002-40 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

I......I...

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY ITEM NO 373500 SIS-04-SI-2002-41 C-F-I Elbow to Pipe C5.21 Cal Block:

27-PTB Category and item number will be R-A and Rl.20 373600 S-856B F-A Rigid Support Fl.20A GANGED WITH S-856A (7/00) 373700 SIS-04-SI-2002-42 C-F-I Pipe to Elbow C5.21 Cal Block:

27-PTB Category and item number will be R-A and Rl.20 373800 SIS-04-SI-2002-43 C-F-I Elbow to Pipe C5.21 Cal Block:

27-PTB NDE METH SUR VOL PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 34 1

23 4

for the 4th interval.

VT-3 SUR VOL for the 4th interval.

SUR VOL Category and item number will be R-A and R1.20 for the 4th interval.

F-A FI.20B 373900 H-21 Rigid Support 374000 SIS-04-SI-2002-44 Pipe to Flange Cal Block:

27-PTB VT-3 C-F-I SUR C5.21 VOL Category and item number will be R-A and Rl.20 for the 4th interval.

374100 SIS-04-SI-2002-45 C-F-i SUR Flange to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

374200 H-22B F-A VT-3 Rigid Support Fl.20A 374300 SIS-04-SI-2002-46 Pipe to Valve SI-866B Cal Block:

27-PTB C-F-I SUR C5.21 VOL Category and item number will be R-A and R1.20 for the 4th interval.

374400 Valve SI-866B 2"

Valve No examination required THIRD PERIOD 1

2 3

4 PAGE: 224

DATE: 03/11/02 PAGE: 225 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 374500 SIS-04-SI-2002-47 C-F-I SUR Valve SI-866B to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

374600 SIS-04-SI-2002-48 C-F-I SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

-- ------- I----------------------------------------------- ------------------------------------------------------------- --------------------------------

374700 S-857B F-A VT-3 Rigid Support FI.20B 374800 SIS-04-SI-2002-49 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

374900 SIS-04-SI-2002-50 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I-----

375000 H-23 F-A VT-3 Rigid Support FI.20B 375100 SIS-04-SI-2002-51 C-F-i SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Rl.20 for the 4th interval.


I----------

375200 SIS-04-SI-2002-52 C-F-i SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

Core Deluge and Cold Leg Injection Header / Dwg.

No. ISI-PRI-2263 376000 M-82A F-A VT-3 X

Anchor Fl.20B PENETRATION 13 (7/00) 376200 SIS-04-SI-2001-50 C-F-i SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION CATEGORY ITEM NO C-F-I C5.21 SIS-04-SI-2001-51 Elbow to Pipe NDE METH SUR VOL PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

23 4

1 2

34 Cal Block:

27-PTB Category and item number will 376400 SIS-04-SI-2001-52 Pipe to Elbow Cal Block:

27-PTB Category and item number will 376500 SIS-04-SI-2001-53 Elbow to Pipe Cal Block:

27-PTB Category and item number will 376600 SIS-04-SI-2001-54 Pipe to Elbow Cal Block:

27-PTB Category and item number will 376700 SIS-04-SI-2001-55 Elbow to Elbow Cal Block:

27-PTB Category and item number will 376800 SIS-04-SI-2001-56 Elbow to Pipe Cal Block:

27-PTB Category and item number will 376900 SIS-04-SI-2001-57 Pipe to Elbow Cal Block:

27-PTB Category and item number will 377000 SIS-04-SI-2001-58 Elbow to Pipe Cal Block:

27-PTB be R-A and RI.20 C-F-I C5.21 be R-A and R1.20 C-F-I C5.21 be R-A and R1.20 C-F-I C5.21 for the 4th interval.

SUR-VOL for the 4th interval.

SUR-VOL for the 4th interval.

SUR VOL be R-A and R1.20 for the 4th interval.

C-F-I C5.21 SUR VOL be R-A and R1.20 for the 4th interval.

C-F-i SUR C5.21 VOL be R-A and R1.20 for the 4th interval.

C-F-I SUR C5.21 VOL be R-A and R1.20 for the 4th interval.

C-F-I SUR C5.21 VOL Category and item number will be 377100 SIS-04-SI-2001-59 Pipe to Elbow Cal Block:

27-PTB R-A and R1.20 C-F-i C5.21 for the SUR VOL 4th interval.

Category and item number 377200 SIS-04-SI-2001-60 Elbow to Pipe Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

C-F-i SUR C5.21 VOL will be R-A and R1.20 for the 4th interval.

SUMMARY

NUMBER 376300 THIRD PERIOD 1

2 3

4 PAGE: 226

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST PERIOD SECC PERI

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 377300 SIS-04-SI-2001-61 C-F-I SUR E.

Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.


I-----------

377400 SIS-04-SI-2001-62 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

377500 SIS-04-SI-2001-63 C-F-I SUR Pipe to Elbow C5.21 VOL ND THIRD OD PERIOD AGE 3

4 1

2 34 Cal Block:

27-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

I--------------------

377600 SIS-04-SI-2001-64 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and Ri.20 for the 4th interval.

377800 H-200 SECTION C-C F-A VT-3 Rigid Support F1.20B FORMERLY H-200 (7/00),

SHOWN AS A GANG HANGER ON P-419, IT IS TWO SEPARATE SUPPORTS CoreDelugS---------------------2 4------------------------

Core Deluge Header / Dwg. No. ISI-PRI-2264 379000 M-82B Anchor F-A F1.20B VT-3 PENETRATION 27 (8/00) 379200 SIS-04-SI-2002-53 C-F-I SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

379300 SIS-04-SI-2002-54 C-F-i SUR Pipe to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.


-------- I-------------------

379400 SIS-04-SI-2002-55 C-F-I SUR E.

Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

379500 SIS-04-SI-2002-56 C-F-i SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

PAGE: 227

DATE: 03/11/02 PAGE: 228 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4

.1 2

3 4

1 2

3 4

379600 SIS-04-SI-2002-57 C-F-I SUR Pipe to Elbow C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

379700 SIS-04-SI-2002-58 C-F-I SUR Elbow to Pipe C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

380000 SIS-04-SI-2002-59 C-F-i SUR Pipe to Tee C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

380100 SIS-04-SI-2002-60 C-F-i SUR Tee to Conc Swage Reducer C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

380200 SIS-04-SI-2002-61 C-F-1 SUR Tee to Conc Swage Reducer C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

Core Deluge Header / Dwg.

No.

ISI-PRI-2265 381000 SIS-02-SI-2012-01 C-F-I S UR Conc Swage Reducer to Tee C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

381100 SIS-02-SI-2012-02 C-F-I SUR Tee to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

381200 SIS-02-SI-2012-03 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

381300 SIS-02-SI-2012-04 C-F-1 SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

381400 SIS-02-SI-2012-05 C-F-1 SUR Pipe to Valve SI-878A C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

DATE: 03/11/02 PAGE: 229 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 381600 SI-878-Al F-A VT-3 X

Rigid Support Fl.20B 381650 SI-878-A2 F-A VT-3 Rigid Support Fl.20A A GANG HANGER WITH SI-878C-2?

381700 SIS-02-SI-2012-06 C-F-I SUR Valve SI-878A to Pipe C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

1-------------------------

381800 SIS-02-SI-2012-07 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

381900 SIS-02-SI-2012-08 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I-------------------------

382000 SIS-02-SI-2012-09 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval..

382100 SIS-02-SI-2012-I0 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

382200 SIS-02-SI-2012-II C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

382300 SIS-02-SI-2012-1 2

C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

382400 SIS-02-SI-2012-13 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY ITEM NO C-F-I C5.30 382500 SIS-02-SI-2012-14 Elbow to Pipe NDE METH SUR FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

Category and item number will be R-A and RI.20 382600 SIS-02-SI-2012-15 C-F-I Pipe to Valve SI-845D C5.30 for the 4th interval.

SUR Category and item number will be R-A and R1.20 for the 4th interval.

383000 SIS-02-SI-2013-01 Tee to Pipe C - F - I S U R C5.30 Category and item number will be R-A and R1.20 for the 383100 SIS-02-SI-2013-02 C-F-I SUR Pipe to Valve SI-878E C5.30 383200 4th interval.

Category and item number will be R-A and Rl.20 for the 4th interval.

Valve SI-878E 2" Valve No examination required 383300 SIS-02-SI-2013-03 Valve SI-878E to Pipe C-F-I SUR CS.30 Category and item number will be R-A and R1.20 for the 4th interval.

383400 SIS-02-SI-2013-04 C-F-i SUR Pipe to Valve SI-845E C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

383500 Valve SI-878A 2" Valve No examination required Core Deluge Header / Dwg.

No.

ISI-PRI-2266 384000 SIS-02-SI-2014-01 Conc Swage Reducer to Tee C-F-I C5.30 SUR Category and item number will be R-A and R1.20 for the 4th interval.

384100 SIS-02-SI-2014-02 C-F-i SUR Tee to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

THIRD PERIOD 1

2 3

4 PAGE: 230

PAGE: 231 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 384200 SIS-02-SI-2014-03 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

384300 SIS-02-SI-2014-04 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

384400 SIS-02-SI-2014-05 C-F-i SUR Pipe to Valve SI-878C C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

I-----------------

384500 Valve SI-878C 2" Valve No examination required 384600 SI-878-Cl F-A VT-3 Rigid Support F1.20B 384700 SI-878-C2 F-A VT-3 Rigid Support Fl.20A A GANG HANGER WITH SI-878A-2?


-------------- I---------------------------------------------------------------------

I--------------------------------

384800 SIS-02-SI-2014-06 C-F-I SUR Valve SI-878C to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

384900 SIS-02-SI-201 4 -0 7 C-F-l SUR E..

Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

385000 SIS-02-SI-2014-08 C-F-i SUR Elbow to Pipe C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

385100 SIS-02-SI-2014-09 C-F-i SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION CATEGORY ITEM NO C-F-1 CS.30 SIS-02-SI-2014-10 Elbow to Pipe NDE METH SUR FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

Category and item number will be R-A and R1.20 for the 4th interval.

385300 SIS-02-SI-2014-II Pipe to Elbow Category and item number 385400 SIS-02-SI-2014-12 Elbow to Pipe Category and item number 385500 SIS-02-SI-2014-13 Pipe to Valve SI-845C Category and item number 386000 SIS-02-SI-2015-01 Tee to Pipe Category and item number 386100 SIS-02-SI-2015-02 Pipe to Elbow Category and item number 386200 SIS-02-SI-2015-03 Elbow to Pipe C-F-I SUR C5.30 will be R-A and R1.20 for the 4th interval.

C-F-I SUR C5.30 will be R-A will be R-A and R1.20 for the 4th C-F-l SUR C5.30 and Rl.20 for the 4th C-F-I SUR C5.30 interval.

interval.

will be R-A and RI.20 for the 4th interval.

C-F-l SUR C5.30 will be R-A and R1.20 for the 4th interval.

C-F-I SUR C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

386300 SIS-02-SI-2015-04 C-F-I SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

386400 SIS-02-SI-2015-05 C-F-l SUR Elbow to Pipe C5.30 Category and item number will be R-A and Ri.20 for the 4th interval.

386500 SIS-02-SI-2015-06 C-F-1 SUR Pipe to ValveE SI-878F C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

SUI2MMARY NUMBER 385200 THIRD PERIOD 1

2 3

4 PAGE: 232

DATE: 03/11/02 PAGE: 233 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 386600 Valve SI-878F 2" Valve No examination required 386700 SIS-02-SI-2015-07 C-F-I SUR Valve SI-878F to Pipe C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

386800 SIS-02-SI-2015-08 C-F-I SUR Pipe to Valve SI-845F C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

Containment Spray Pump P-14A and P-14B Discharge / Dwg.

No.

ISI-PRI-2267 387000 SIS-06-SI-2003-01 C-F-I Reducer to Tee C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

387100 SIS-06-SI-2003-02 C-F-1 Tee to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

387200 SIS-06-SI-2003-03 C-F-i Pipe to Elbow C5.11A Category and item number will be R-A and Ri.20 for the 4th interval.

387300 SIS-06-SI-2003-04 C-F-i Elbow to Pipe CS.IIA Category and item number will be R-A and RI.20 for the 4th interval.

387400 S-870 F-A VT-3 Rigid Support F1.20B


.I.-----

I.--

387500 SIS-06-SI-2003-05 C-F-i Pipe to Elbow C5.iIA Category and item number will be R-A and RI.20 for the 4th interval.

387600 SIS-06-SI-2003-06 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

POINT BEACH NUCLEAR PLANT UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 387700 H-01 F-A VT-3 Spring Hanger F1.20C 387900 SIS-06-SI-2003-07 C-F-1 Pipe to Valve SI-860A C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

388000 Valve SI-860A 6"

Valve No examination required 388100 SIS-06-SI-2003-08 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

388200 SIS-06-SI-2003-09 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

388300 SIS-06-SI-2003-I0 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

388400 SIS-06-SI-2003-II C-F--

Pipe to Elbow C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

388500 SIS-06-SI-2003-12 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

388600 H-02 F-A VT-3 Spring Hanger FI.20C 388800 SIS-06-SI-2003-13 C-F-I Pipe to Valve SI-860B C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

DATE: 03/11/02 PAGE: 234

PAGE: 235 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 388900 Valve SI-860B 6"

Valve No examination required 389000 SIS-06-SI-2004-01 C-F-I Reducer to Tee C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

389100 SIS-06-SI-2004-02 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

389200 SIS-06-SI-2004-03 C-F-i Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

389300 SIS-06-SI-2004-04 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I---------------I--------------------------------------------------------------- ------------------- ---------------------------------------------

389400 S-873 F-A VT-3 X

Rigid Support F1.20B SHOWN AS DUAL RESTRAINT


-- I-------------------------------------------

389500 SIS-06-SI-2004-05 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and Ri.20 for the 4th interval.


I---------------------------------

389600 SIS-06-SI-2004-06 C-F-1 Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

389700 H-08 F-A VT-3 Spring Hanger F1.20C

..I ---------- -

I-------------------

389900 SIS-06-SI-2004-07 C-F-I Pipe to Valve SI-860C C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

....... I--------------------------

......... I------------------------------------

I---------------------

I------------------------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 390000 Valve SI-860C 6" Valve CATEGORY NDE ITEM NO METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

No examination required 390100 SIS-06-SI-2004-08 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

390200 SIS-06-SI-2004-09 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

390300 SIS-06-SI-2004-I0 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

390400 SIS-06-SI-2004-II Pipe to Elbow C-F-i C5. 11A Category and item number will be R-A 390500 SIS-06-SI-2004-12 Elbow to Pipe Category and item number will be R-A 390600 H-09 Spring Hanger 390800 SIS-06-SI-2004-13 Pipe to Valve SI-860D and RI.20 C-F-i C5.lIA and R1.20 F-A FI.20C for the 4th interval.

for the 4th interval.

VT-3 X

C-F-i C5. IIA Category and item number will be R-A and R1.20 for the 4th interval.

390900 Valve SI-860D 6" Valve No examination required THIRD PERIOD 1

2 3

4 PAGE: 236

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 u T

NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 Cold Leg Injection Header / Dwg. No.

ISI-PRI-2268 392000 SIS-04-SI-2001-65 C-F-I SUR Pipe to Tee C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and RI.20 for the 4th interval.

I--------------

392100 SIS-04-SI-2001-66 C-F-I SUR Tee to Reducer C5.21 VOL Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I--------------------------- --------------

I------------------------------------------

392200 SIS-04-SI-2001-67 C-F-l SUR Tee to Reducer C5.21 VOL 3

4 1

2 3

4 Cal Block:

27-PTB Category and item number will be R-A and R1.20 for the 4th interval.

392300 H-200 F-A VT-3 x

Rigid Support FI.20B Formerly SI-02 (7/00),

Shown as a gang hanger on P-419, it is two separate supports, Section A-A on support drawing.

393000 SIS-02-SI-2016-01 C-F-I SUR Conc Swage Reducer to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I------------------------------------------

393100 SIS-02-SI-2016-03 C-F-l SUR Elbow to Pipe C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

393200 SIS-02-SI-2016-04 C-F-l SUR Pipe to Elbow C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

393300 SIS-02-SI-2016-05 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

393400 SIS-02-SI-2016-06 C-F-I SUR Pipe to Valve SI-878B C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

I-----------------------------

PAGE: 237

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION CATEGORY NDE ITEM NO METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND THIRD PERIOD PERIOD OUTAGE 1

2234 1

23 4

Valve SI-878B 2" Valve No examination required 393600 SI-878-BI Rigid Support 393700 SIS-02-SI-2016-07 Valve SI-878B to Pipe F-A VT-3 Fl. 20B C-F-I C5.30 SUR Category and item number will be R-A and R1.20 for the 4th interval.

393800 SIS-02-SI-2016-08 C-F-I SUR Pipe to Valve SI-845B C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

394000 SIS-02-SI-2017-01 Conc Swage Reducer to Elbow C-F-S C5.30 SURE Category and item number will be R-A and R1.20 for the 4th interval.

394100 SIS-02-SI-2017-03 C-F-i SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

394200 SIS-02-SI-2017-04 C-F-i SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

394300 SIS-02-SI-2017-05 C-F-i SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

394400 SIS-02-SI-2017-06 C-F-i SUR Pipe to Valve SI-878D C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

394500 Valve SI-878D 2" Valve No examination required

SUMMARY

NUMBER 393500 PAGE: 238

DATE: 03/11/02 PAGE: 239 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 394600 SI-878-DI F-A VT-3 Rigid Support FI.20B 394700 SIS-02-SI-2017-07 C-F-I SUR Valve SI-878D to Pipe C5.30 Category and item number will be R-A and Rl.20 for the 4th interval.

394800 SIS-02-SI-2017-08 C-F-i SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.


----------- ------------------------- I-------

394900 SIS-02-SI-2017-09 C-F-I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

I--------------------------------

395000 SIS-02-SI-2017-I0 C-F-i SUR Pipe to Elbow C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

3 95100 SIS-02-SI-2017 -1 C -F -I SUR Elbow to Pipe C5.30 Category and item number will be R-A and R1.20 for the 4th interval.

395200 SIS-02-SI-2017-12 C-F-I SUR Pipe to Valve SI-845A C5.30 Category and item number will be R-A and RI.20 for the 4th interval.

RHR to Safety Injection Pump Suction / Dwg. No.

ISI-PRI-2269 3 9 6 0 0 0 A C - 0 6 -S I -2 0 02 - 1 1A C -F -

I Pipe to Tee C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

396100 AC-06-SI-2002-11B C-F-I Tee to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

I----------------------

3 9 6 2 0 0 A C - 0 6 - S I - 2 0 0 2 -

I IC C - F - l Pipe to Valve 2RH-706A C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION Valve 2RH-706A 6"

Valve CATEGORY NDE ITEM NO METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

No examination required 396400 AC-06-SI-2002-11D C-F-I Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

396500 AC-06-SI-2002-12 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

396600 AC-06-SI-2002-13 C-F-I Elbow to Pipe CS.11A Category and item number will be R-A and R1.20 for the 4th interval.

396800 AC-06-SI-2002-14 Pipe to Elbow C-F-I C5. 11A Category and item number will be R-A and R1.20 for the 4th interval.

396900 AC-06-SI-2002-15 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

397000 2H-24 F-A VT-3 Spring Hanger FI.20C 397300 2H-24A Rigid Support 397500 AC-06-SI-2002-16 Pipe to Elbow F-A VT-3 FI.20B C-F-I C5. 11A Category and item number will be R-A and R1.20 for the 4th interval.

397600 2H-23 F-A VT-3 X

Spring Hanger F1.20C

SUMMARY

NUMBER 396300 THIRD PERIOD 1

2 3

4 PAGE: 240

DATE: 03/11/02 PAGE: 241 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 397800 AC-06-SI-2002-17 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

397900 AC-06-SI-2002-18 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

I----------------------------------------------------------------

398000 AC-06-SI-2002-19 C-F-I X

Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

398100 AC-06-SI-2002-20 C-F-i Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I--------------------------------------

398200 AC-06-SI-2002-21 C-F-l Elbow to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

398300 AC-06-SI-2002-2 2 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I......I----------

398400 AC-06-SI-2002-23 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

398500 AC-06-SI-2002-24 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I------------

398600 R-2376 F-A VT-3 Rigid Support F1.20B 398700 R-2375 F-A VT-3 Rigid Support Fl.20B

DATE: 03/11/02 PAGE: 242 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2

COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 398800 R-2315 F-A VT-3 X

Rigid Support FI.20C GANGED WITH SI-301R-I-R2315 AND R-2315A (7/00) 398900 AC-06-SI-2002-25 C-F-I Pipe to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

Containment Spray Pumps P-14A and P-14B Suction / Dwg.

No.

ISI-PRI-2270 400100 SIS-06-CS-2001-01 C-F-I Valve SI-870A to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

400200 SIS-06-CS-2001-02 C-F-I Pipe to Valve SI-858A C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

400300 Valve SI-858A 6"

Check Valve No examination required 400400 SIS-06-CS-2001-03 C-F-i Valve SI-858A to Tee C5.IIA Category and item number will be R-A and RI.20 for the 4th interval.

400500 3H-01A F-A VT-3 X

Spring Support FI.20C 400700 SIS-06-CS-2001-04 C-F-I Tee to Reducer C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

400800 SIS-08-CS-2001-01 C-F-I Reducer to Flange C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

400900 Containment Spray Pump P-14A Pump No examination required

PAGE: 243 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 402100 SIS-06-CS-2002-01 C-F-I Valve SI-870B to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

402200 SIS-06-CS-2002-02 C-F-1 Pipe to Valve SI-858B C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

4 0 2 3 0 0 V a l v e S I - 8 5 8 B 6"

Check Valve No examination required 402400 SIS-06-CS-2002-03 C-F-1 Valve SI-858B to Tee C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

402500 3H-01B F-A VT-3 Spring Support FI.20C 402700 SIS-06-CS-2002-04 C-F-I Tee to Reducer C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

402800 SIS-08-CS-2002-01 C-F-I Reducer to Flange C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

402900 Containment Spray Pump P-14B Pump No examination required required--

Loop A Main Steam Inside Containment / Dwg.

No.

ISI-PRI-2271 402990 MS-30-MS-2001-12LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

403000 MS-30-MS-2001-1 2

C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and R1.20 for the 4th interval.

I..................--

POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 403010 MS-30-MS-2001-12LDO C-F-2 SUR Outside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

403080 MS-30-MS-2001-13LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

403090 MS-30-MS-2001-13LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

403100 MS-30-MS-2001-13 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

45-PTB Category and item number will be R-A and R1.20 for the 4th interval.

403110 MS-30-MS-2001-13LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

403290 MS-30-MS-2001-14LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

403300 MS-30-MS-2001-14 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

45-PTB, 46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

Thickness change at this weld.

Upstream uses block 45-PTB and downstream uses 46-PTB.

403310 MS-30-MS-2001-14LDI C-F-2 SUR Inside Downstream Long Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

403320 MS-30-MS-2001-14LDO C-F-2 SUR Outside Downstream Long Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

403380 MS-30-MS-2001-15LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

DATE: 03/11/02 PAGE: 244

DATE: 03/11/02 PAGE: 245 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METE 1

2 3

4 1

2 3

4 1

2 34 403390 MS-30-MS-2001-15LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

403400 MS-30-MS-2001-15 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

403410 MS-30-MS-2001-15LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

403490 MS-30-MS-2001-16LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

46-PTB Component will be deleted from the fourth interval ISI Program.

403500 MS-30-MS-2001-16 C-F-2 SUR Pipe to Penetration C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and Rl.20 for the 4th interval.

403510 MS-69/A-2 F-A VT-3 Anchor Fl.20B PENETRATION 1 403520 MS-30-MS-2001-16LD C-F-2 SUR Downstream Longiaudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.


I-----------------

403590 MS-30-MS-2001-17LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

403600 MS-30-MS-2001-17 C-F-2 SUR Penetration to Pipe C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and RI.20 for the 4th interval.

I 403610 MS-30-MS-2001-17LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 Loop B Main Steam Inside Containment / Dwg.

No.

ISI-PRI-2272 405000 MS-06-MS-2002-01 C-F-2 Branch Connection to Pipe C5.51A Category and item number will be R-A and Rl.20 for the 4th interval.

405100 MS-06-MS-2002-02 C-F-2 Pipe to Cap C5.51A Category and item number will be R-A and RI.20 for the 4th interval.

406100 MS-30-MS-2002-09-BC C-F-2 SUR 6" Branch Connection C5.81 Category and item number will be R-A and RI.20 for the 4th interval.

406190 MS-30-MS-2002-1OLU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406200 MS-30-MS-2002-10 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

406210 MS-30-MS-2002-10LDI C-F-2 SUR Inside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406220 MS-30-MS-2002-10LDO C-F-2 SUR Outside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406280 MS-30-MS-2002-11LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406290 MS-30-MS-2002-11LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406300 MS-30-MS-2002-11 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 246

DATE: 03/11/02 PAGE: 247 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD SUMIMARY EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 406310 MS-30-MS-2002-llLD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406490 MS-30-MS-2002-12LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406500 MS-30-MS-2002-12 C-F-2 SUR Pipe to Elbow C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and Rl.20 for the 4th interval.


I-------

406510 MS-30-MS-2002-12LDI C-F-2 SUR Inside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

4 06520 M S-30-MS-2002-12LDO C-F-2 SUR Outside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406680 MS-30-MS-2002-13LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406690 MS-30-MS-2002-13LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.


I---------- 1--------------------------------------------------------------

406700 MS-30-MS-2002-13 C-F-2 SUR Elbow to Elbow C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and RI.20 for the 4th interval.


I-----------------------------

406710 MS-30-MS-2002-13LDI C-F-2 SUR Inside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

I----------------------------

... I-----------------------------------------------

406720 MS-30-MS-2002-13LDO C-F-2 SUR E..

Outside Downstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY ITEM NO NDE METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND THIRD PERIOD PERIOD OUTAGE 1

23 4

1 2

34 406780 MS-30-MS-2002-14LUI C-F-2 SUR Inside Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406790 MS-30-MS-2002-14LUO C-F-2 SUR Outside Upstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406800 MS-30-MS-2002-14 C-F-2 SUR Elbow to Pipe C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

406810 MS-30-MS-2002-14LD Downstream Longitudinal Weld Cal Block:

45-PTB Component will be deleted from the 406890 MS-30-MS-2002-15LU Upstream Long Weld Cal Block:

45-PTB Component will be deleted from the 406900 MS-30-MS-2002-15 Pipe to Penetration Cal Block:

46-PTB C-F-2 SUR C5.52 VOL fourth interval ISI Program.

C-F-2 SUR C5.52 VOL fourth interval ISI Program.

C-F-2 SUR C5.51 VOL Category and item number will be R-A and Rl.20 for the 4th interval.

406910 MS-65/A-l F-A VT-3 Anchor FI.20B PENETRATION 2 406920 MS-30-MS-2002-15LD Downstream Longitudinal Weld C-F-2 SUR C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

406990 MS-30-MS-2002-16LU C-F-2 SUR Upstream Long Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

407000 MS-30-MS-2002-16 C-F-2 SUR Penetration to Pipe C5.51 VOL Cal Block:

46-PTB Category and item number will be R-A and R1.20 for the 4th interval.

PAGE: 248

DATE: 03/11/02 PAGE: 249 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 407010 MS-30-MS-2002-16LD C-F-2 SUR Downstream Longitudinal Weld C5.52 VOL Cal Block:

45-PTB Component will be deleted from the fourth interval ISI Program.

I.---

I...............................---

RWST to RHR, SI, and Containment Spray Pumps / Dwg.

No.

ISI-PRI-2273 408000 AC-16-SI-2001-FB Flange Bolting No examination required due to bolting is 2" or less in diameter.

408100 AC-16-SI-2001-01 C-F-I Flange to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

408200 AC-16-SI-2001-02 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

408300 AC-16-SI-2001-03 C-F-l Pipe to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

408400 AC-16-SI-2001-04 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

408500 S-734 F-A VT-3 Component Support Fl.20B 408600 SI-151R-2H10 F-A VT-3 Component Support FI.20B 408700 AC-16-SI-2001-05 C-F-I Pipe to Tee CS.IIA Category and item number will be R-A and R.20 for the 4th interval....................................................

408800 AC-16-SI-2001-06 C-F-I Tee to Reducer C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 250 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 408900 AC-16-SI-2001-07 C-F-I Tee to Reducer C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

RWST to RP.R Pumps / Dwg.

No.

ISI-PRI-2274 410000 AC-10-RHR-2007-01 C-F-I Reducer to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

410100 AC-10-RHR-2007-02 C-F-I Pipe to Tee C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

410200 AC-10-RHR-2007-03 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

410300 AC-10-RHR-2007-04 C-F-I Pipe to Tee C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

410400 AC-10-RHR-2007-05 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

410500 SI-151R-H204 F-A VT-3 Component Support FI.20B 410600 AC-10-RER-2007-06 C-F-I Pipe to Valve 2SI-856A C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

410700 Valve 2SI-856A 8"

Motor Operated Valve No examination required 410800 AC-10-RHR-2007-07 C-F-i Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 251 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 410900 AC-10-RHR-2007-08 C-F-i Pipe to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

411000 AC-10-RHR-2007-09 C-F-i Pipe to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

411100 AC-10-RHR-2007-10 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

411200 AC-10-RHR-2007 -lI C-F-I Pipe to Valve 2SI-856B C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

411300 Valve 2SI-856B 8"

Motor Operated Valve No examination required 412000 AC-08-RiR-2007-01 C-F-1 Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

412100 AC-08-RHR-2007-02 C-F-I Pipe to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

412200 AC-08-RHR-2007-03 C-F-I Pipe to Valve 2SI-742 CS.lIA Category and item number will be R-A and Rl.20 for the 4th interval.

RWST to Safety Injection

& Containment Spray Pumps /

Dwg.

No.

ISI-PRI-2275 4 13 000 A C SI -2 001 -01 C -F -i Reducer to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

4 1 3 1 0 0 A C - 1 2 - S I - 2 0 0 1 - 0 2 C - F - l Pipe to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

1----------------------------

POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 413200 SI-151R-2H9 F-A VT-3 Pipe Support Fl.20B Located under floor plates outside safety injection pump room.

413300 AC-12-SI-2001-03 C-F-I Pipe to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

413400 SI-151R-2H8 F-A VT-3 Pipe Support Fl.20B Located under floor plates outside safety injection pump room.

413500 AC-12-SI-2001-04 C-F-I Pipe to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

413600 S-733 F-A VT-3 Pipe Support Fl.20A Located under floor plates outside safety injection pump room.

413700 AC-12-SI-2001-05 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

413800 AC-12-SI-2001-06 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

413900 0101 F-A VT-3 Pipe Support FI.20B Located under floor plates outside safety injection pump room.

414000 S-739 F-A VT-3 Pipe Support F1.20B Located under floor plates outside safety injection pump room.

414100 AC-12-SI-2001-07 C-F-1 Pipe to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

DATE: 03/11/02 PAGE: 252

DATE: 03/11/02 PAGE: 253 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 414200 AC-12-SI-2001-08 C-F-i Elbow to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

414300 SI-151R-2H7 F-A VT-3 Pipe Support Fl.20B Located under floor plates outside safety injection pump room.

414400 SI-151R-2H6A F-A VT-3 Pipe Support Fl.20B Located under floor plates inside safety injection pump room.

414500 S-738 F-A VT-3 Pipe Support Fl.20B Located under floor plates inside safety injection pump room.

414600 AC-12-SI-2001-09 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

414700 AC-12-SI-2001-10 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I------------------------

414800 S-737 F -A VT -3 S.

Pipe Support F1.20B Located under floor plates inside safety injection pump room.

I-----------------------------

I---------------

414900 SI-151R-2H6 F-A VT-3 Pipe Support Fl.20B Located under floor plates inside safety injection pump room.

415000 AC-12-SI-2001-11 C-F-i Pipe to Tee C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 RWST to Safety Injection & Containment Spray Pumps /

Dwg.

No. ISI-PRI-2276 415100 AC-12-SI-2001-12 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

415200 SI-l5lR-2H5 F-A VT-3 Pipe Support FI.20B Located under floor plates inside safety injection pump room.

415300 AC-12-SI-2001-13 C-F-I Pipe to Tee C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

415400 AC-12-SI-2001-14 C-F-I Tee to Tee C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

415500 AC-12-SI-2001-15 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

415600 AC-12-SI-2001-16 C-F-I Pipe to Valve 2SI-825A C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

415700 Valve 2SI-825A 12" Valve No examination required 415800 AC-12-SI-2001-17 C-F-I Valve 2SI-825A to Tee C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

415900 AC-12-SI-2001-18 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

416000 AC-12-SI-2001-19 C-F-i Pipe to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 254

DATE: 03/11/02 PAGE: 255 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 416100 AC-12-SI-2001-20 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.


---------------- I--------------------------------------------------

4 1 62 00 A C S I -2 001 -21 C -F -

I Pipe to Valve 2SI-825B C5.11A Category and item number will be R-A and RI.20 for the 4th interval.


------------- I------------------------

1----------------------------------

416300 Valve 2SI-825B 12" Valve No examination required 416400 AC-12-SI-2001-22 C-F-I Valve 2SI-825B to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I---------------,---------------------------------------------------------------------------------------------

416500 2HIA F-A VT-3 Pipe Support FI.20B Located under floor plates inside safety injection pump room.

I-------- ------------

416600 AC-12-SI-2001-23 C-F-I Pipe to Elbow C5.l1A Category and item number will be R-A and Rl.20 for the 4th interval.

416700 AC-12-SI-2001-24 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

416800 AC-12-SI-2001-25 C-F-i Pipe to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

416900 AC-12-SI-2001-26 C-F-I Pipe to Tee C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

417000 AC-12-SI-2001-27 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

I------------------------------------------------------------------------------

I-------

DATE: 03/11/02 PAGE: 256 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2

COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 417100 AC-12-SI-2001-28 C-F-I Pipe to Tee C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

417200 AC-12-SI-2001-29 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

417300 AC-12-SI-2001-30 C-F-I Pipe to Tee C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

417400 AC-12-SI-2001-31 C-F-I Tee to Reducer C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

417500 AC-12-SI-2001-32 C-F-I Tee to Reducer C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

418000 AC-08-SI-2003-01 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

418100 AC-08-SI-2003-02 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

418200 AC-08-SI-2003-03 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

418300 AC-08-SI-2003-04 C-F-I Pipe to Valve 2SI-826A C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

418400 Valve 2SI-826A 8" Valve No examination required

DATE: 03/11/02 PAGE: 257 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 RWST to Safety Injection Pumps / Dwg.

No.

ISI-PRI-2277 419000 AC-06-SI-2004-01 C-F-I Reducer to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

419100 S-743 F-A VT-3 Pipe Support FI.20B Located under floor plates inside safety injection pump room.

419200 AC-06-SI-2004-02 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

419300 AC-06-SI-2004-03 C-F-I Elbow to Pipe CS.l1A Category and item number will be R-A and RI.20 for the 4th interval.

419400 AC-06-SI-2004-04 C-F-I Pipe to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

419500 AC-06-SI-2004-05 C-F-i Pipe to Valve 2SI-896A CS.IIA Category and item number will be R-A and R1.20 for the 4th interval.

419600 Valve 2SI-896A 6" Motor Operated Valve No examination required 420000 AC-06-SI-2005-01 C-F-i Reducer to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

420100 AC-06-SI-2005-02 C-F-i Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

420200 AC-06-SI-2005-03 C-F-i Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

-- -I -- -

POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD SUMMAfRY EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 420300 S-743 part B F-A VT-3 Pipe Support Fl.20B Located under floor plates inside safety injection pump room.

Will be examined as part of S-743 on line AC-06-SI-2004.

420400 AC-06-SI-2005-04 C-F--

Pipe to Elbow C5.11A Category and item number will be R-A and R!.20 for the 4th interval.

420500 AC-06-SI-2005-05 C-F-I Elbow to Pipe C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

420600 AC-06-SI-2005-06 C-F-i Pipe to Valve 2SI-896B C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

420700 Valve 2SI-896B 6"

Motor Operated Valve No examination required RWST to Containment Spray Pumps / Dwg.

No.

ISI-PRI-2278 421000 AC-06-CS-2001-01 C-F-I Tee to Pipe C5.11A Category and item number will be R-A and RI.20 for the 4th interval.

421100 AC-06-CS-2001-02 C-F-I Pipe to Elbow C5.lIA Category and item number will be R-A and Rl.20 for the 4th interval.

421200 SI-151R-3-2HIA F-A VT-3 Support Fl.20A 421300 SI-151R-3-2HlA-IWA Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

DATE: 03/11/02 PAGE: 258

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 421400 AC-06-CS-2001-03 Elbow to Pipe CATEGORY NDE ITEM NO METH C-F-I C5. *IA FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

Category and item number 421500 AC-06-CS-2001-04 Pipe to Elbow Category and item number 421600 AC-06-CS-2001-05 Elbow to Valve 2SI-870A will be R-A and R1.20 for the 4th interval.

C-F-I CS.11A will be R-A and R1.20 for the 4th interval.


-- ---- - -- -- -- -- -- - -- -- ---- --- -- -- -- -- -....... I-C-F-I CS.11A Category and item number will be R-A and R1.20 for the 4th interval.

421700 Valve SI-870A 6" Valve No examination required 422000 AC-06-CS-2002-01 C-F--

Tee to Pipe CS. 11A Category and item number will be R-A and R1.20 for the 4th interval.

422100 AC-06-CS-2002-02 C-F-i Pipe to Elbow C5. 11A Category and item number will be R-A and R1.20 for the 4th interval.

422200 SI-151R-3-2H2A F-A VT-3 Support Fl.20A 422300 SI-151R-3-2H2A-IWA Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

422400 AC-06-CS-2002-03 C-F-Elbow to Pipe C5.11A Category and item number will be R-A and Rl.20 for the 4th interval.

422500 AC-06-CS-2002-04 C-F-I Pipe to Elbow C5.11A Category and item number will be R-A and R1.20 for the 4th interval.

PAGE: 259 THIRD PERIOD 1234

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 422600 AC-06-CS-2002-05 Elbow to Valve 2SI-870B CATEGORY NDE ITEM NO METH C-F-I C5. IIA FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

Category and item number will be R-A and RI.20 for the 4th interval.

422700 Valve SI-870B 6"

Valve No examination required Auxiliary Feedwater to Steam Generator A /

Dwg.

No.

ISI-PRI-2279 425000 Valve 2AF-103 Check Valve No examination required.

425100 AF-03-AFW-2001-1 Valve 2AF-103 to Pipe Category and item number 425200 AF-03-AFW-2001-2 Pipe to Valve 2AF-32 VOL X

will be R-A and R1.20 for the 4th interval.

VOL X

Category and item number will be R-A and R1.20 for the 4th interval.

425300 Valve 2AF-32 Motor Operated Valve No examination required.

425400 AF-03-AFW-2001-3 VOL Valve 2AF-32 to Pipe Category and item number 425500 AF-03-AFW-2001-4 Pipe to Elbow will be R-A and R1.20 for the 4th interval.

VOL Category and item number will be R-A and R1.20 for the 4th interval.

425600 AF-03-AFW-2001-5 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

425700 EB-10-H201 VT-3 X

Component Support Category and item number will be F-A and F1.20A for the 4th interval.

THIRD PERIOD 1

2 3

4 PAGE. 260

DATE: 03/11/02 PAGE: 261 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 425800 EB-10-2H3 VT-3 X

Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

425900 AF-03-AFW-2001-6 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

426000 AF-03-AFW-2001-7 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

426100 AF-03-AFW-2001-8 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

426200 AF-03-AFW-2001-9 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

426250 EB-10-H203 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

426300 EB-10-S893 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

426400 EB-10-S893-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

426500 AF-03-AFW-2001-10 VOL Pipe to Tee Category and item number will be R-A and Rl.20 for the 4th interval.

426600 Valve 2AF-106 Check Valve No examination required.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 426700 AF-03-AFW-2001-11 Valve 2AF-106 to Pipe CATEGORY NDE ITEM NO METH VOL FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

X Category and item number will be R-A and Rl.20 for the 4th interval.

426800 DB-3-2H2 VT-3 X

Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

426900 DB-3-2H2-IWA VT-l X

Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

427000 AF-03-AFW-2001-12 VOL Pipe to Valve 2AF-56 Category and item number will be R-A and R1.20 for the 4th interval.

427100 Valve 2AF-56 Motor Operated Valve No examination required.

427200 AF-03-AFW-2001-13 Valve 2AF-56 to Pipe VOL X

Category and item number will be R-A and Rl.20 for the 4th interval.

427300 AF-03-AFW-2001-14 VOL X

Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

4.27400 EB-10-HYY VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

427500 EB-10-HYY-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

427600 AF-03-AFW-2001-15 VOL X

Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

I............................---------------------------------------------

X THIRD PERIOD 1

2 3

4 PAGE: 262

DATE: 03/11/02 PAGE: 263 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 427700 EB-l0-S892 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

427800 AF-03-AFW-2001-16 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

427900 AF-03-AFW-2001-17 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

428000 AF-03-AFW-2001-18 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

428100 AF-03-AFW-2001-19 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

428200 AF-03-AFW-2001-20 VOL Pipe to Tee Category and item number will be R-A and R1.20 for the 4th interval.

I----------------------------------

428300 AF-03-AFW-2001-21 VOL Tee to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

428400 EB-10-S894 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

428500 EB-10-S894-IWA VT-Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

I----------------------------------------------

DATE: 03/11/02 PAGE: 264 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 Auxiliary Feedwater to Steam Generator A / Dwg.

No.

ISI-PRI-2280 428600 AF-03-AFW-2001-22 VOL X

Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

428700 AF-03-AFW-2001-23 VOL X

Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

428800 AF-03-AFW-2001-24 VOL Pipe to Flange Category and item number will be R-A and R1.20 for the 4th interval.

428900 AF-03-AFW-2001-25 VOL Flange to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

429000 EB-10-H27 VT-3 X

Spring Support Category and item number will be F-A and FI.20A for the 4th interval.

429100 EB-10-H27-IWA VT-l X

Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

429200 AF-03-AFW-2001-26 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

429300 AF-03-AFW-2001-27 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

429400 EB-10-WEPCO-399 VT-3 Spring Support Category and item number will be F-A and Fl.20A for the 4th interval.

429500 EB-10-WEPCO-399-IWA VT-Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

~............................................................................................--------------------------.........................

DATE: 03/11/02 PAGE: 265 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 429600 EB-10-$903 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

429700 EB-10-S903-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

429800 AF-03-AFW-2001-28 VOL Pipe to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

I------------------------------

429900 AF-03-AFW-2001-29 VOL Pipe to Elbow Category and item number will be R-A and RI.20 for the 4th interval.

430000 EB-10-HI5 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

430100 EB-10-HlS-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.


--------- I------------------------------------------

I---------------------------------

430200 AF-03-AFW-2001-30 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

430300 EB-10-H202 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

430400 EB-10-H16 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

430500 EB-10-H17 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

- --------------------------------- I------------------------------------------ ----------------------------

DATE: 03/11/02 PAGE: 266 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 430600 EB-10-S904 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

430700 EB-10-s904-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

430800 AF-03-AFW-2001-31 VOL Pipe to Pipe Category and item number will be R-A and RI.20 for the 4th interval.

430900 EB-10-HI8 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

431000 EB-10-H19 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

431100 EB-I0-$776 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

431200 EB-10-S776-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

I------------------------------------------------ ------------------------

431300 AF-03-AFW-2001-32 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

431400 AF-03-AFW-2001-33 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

431500 EB-10-S905 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

DATE: 03/11/02 PAGE: 267 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 431600 EB-10-H20 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

431700 EB-10-H20-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.


I -------------------------------------------------------------------------

I--------------------------------------------------------

431800 AF-03-AFW-2001-34 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

~----------------------------------- --------------------------------------------------------------------------------

431900 AF-03-AFW-2001-35 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

432000 EB-10-H21 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

11---------------------------------------------------------- --------------------------------------

432100 EB-10-H22 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

432200 EB-10-s906 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

432300 EB-10-S906-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

432400 AF-03-AFW-2001-36 VOL Pipe to Elbow Category and item number will be R-A and RI.20 for the 4th interval.

432500 AF-03-AFW-2001-37 VOL Elbow to Pipe Category and item number will be R-A and RI.20 for the 4th interval.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATIO NUMBER IDENTIFICA 432600 EB-10-$777 N AREA

.TION CATEGORY HUE ITEM NO METH VT-3 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 3

4 Component Support Category and item number 432700 EB-10-S777-IWA Welded Attachment Category and item number 432800 EB-10-H23 will be F-A and Fl.20A for the 4th interval.

VT-I will be C-C and C3.20 for the 4th interval.

VT-3 Component Support Category and item number will be F-A and F1.20A for the 4th interval.

I----

433000 AF-03-AFW-2001-38 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

433100 AF-03-AFW-2001-39 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

433200 AF-03-AFW-2001-40 VOL Pipe to Elbow Category and item number will be R-A and RI.20 for the 4th interval.

433300 AF-03-AFW-2001-41 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

I-----------

I-----------------

433400 AF-03-AFW-2001-42 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.


I......I---------------------------------------------

433500 AF-03-AFW-2001-43 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

433600 EB-10-H24 Component Support VT-3 Category and item number will be F-A and F!.20A for the 4th interval.

I--------

THIRD PERIOD 1

2 3

4 PAGE: 268

DATE: 03/11/02 PAGE: 269 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 433700 AF-03-AFW-2001-44 VOL Pipe to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

433800 EB H 25 VT -3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

I-------------------

433900 EB-10-H26 VT-3 Component Support Category and item number will be F-A and F1.20A for the 4th interval.

I------------

434000 EB-10-S907 VT-3 Component Support Category and item number will be F-A and F1.20A for the 4th interval.


------------ 1---------

I-----------------

434100 EB-10-S907-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

434200 AF-03-AFW-2001-45 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

434300 AF-03-AFW-2001-46 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

434400 AF-03-AFW-2001-47 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

I--------------------------------------------------------------------------------

1------------------------

434500 AF-03-AFW-2001-48 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

434600 EB-10-H32 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

DATE: 03/11/02 PAGE: 270 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 434700 EB-10-2H31 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

434800 AF-03-AFW-2001-49 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

434900 AF-03-AFW-2001-50 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

435000 EB-10-S908 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

435100 EB-10-s908-IWA VT-i Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

435200 AF-03-AFW-2001-51 VOL Pipe to Elbow Category and item number will be R-A and RI.20 for the 4th interval.

435300 AF-03-AFW-2001-52 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

435400 EB-10-H30 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

435500 AF-03-AFW-2001-53 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

435600 AF-03-AFW-2001-54 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 271 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METE 1

2 3

4 1

2 3

4 1

2 34 435700 AF-03-AFW-2001-55 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

...I ------------- ------------------------------

435800 AF-03-AFW-2001-56 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

435900 AF-03-AFW-2001-57 VOL X

Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.


I-------------- ----------------------------------------------------------------------------------------

436000 AF-03-AFW-2001-58 VOL X

Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

436100 EB-10-2H29 VT-3 X

Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

436200 AF-03-AFW-2001-59 VOL Pipe to Flued Head Category and item number will be R-A and R1.20 for the 4th interval.

I--------------------------------------

Auxiliary Feedwater to Steam Generator A / Dwg. No.

ISI-PRI-2281 sh. 1 436900 EB-10-A12 VT-3 Anchor Category and item number will be F-A and FI.20A for the 4th interval.

Auxiliary Feedwater to Steam Generator A / Dwg.

No.

ISI-PRI-2281 437000 AF-03-AFW-2001-60 VOL Flued Head to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

437100 AF-03-AFW-2001-61 VOL Pipe to Elbow Category and item number will be R-A and RI.20 for the 4th interval.


...I------------------------------------------------------------------

DATE: 03/11/02 PAGE: 272 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 437200 AF-03-AFW-2001-62 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

437300 EB-10-H205 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

1---------------------------

I------------------------------

437500 AF-03-AFW-2001-63 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

437600 AF-03-AFW-2001-64 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.


----------- I----------

437700 AF-03-AFW-2001-65 VOL Pipe to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

437800 EB-10-2R128-3 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

438000 EB-10-2RI27-16 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.


I---------------

I-------------------

I----------------------------------

438200 AF-03-AFW-2001-66 VOL Pipe to Elbow Category and item number will be R-A and RI.20 for the 4th interval.

438300 AF-03-AFW-2001-67 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

438400 EB-10-H204 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

DATE: 03/11/02 PAGE: 273 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 438600 AF-03-AFW-2001-68 VOL Pipe to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

438700 EB-10-2RI29-S39 VT-3 Component Support Category and item number will be F-A and F1.20A for the 4th interval.


1------------------------------------------------------------------------

438900 AF-03-AFW-2001-69 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

439000 AF-03-AFW-2001-70 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

439100 EB-10-H203 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

439300 EB-10-2RI20-S39 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

......-------I-- -----------------------------------------------------------------------------------------------------------------------------------

439500 AF-03-AFW-2001-71 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.


I-------------------

I------------------------------------------------

439600 AF-03-AFW-2001-72 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

439700 EB-10-H202 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.


.... I------------------------------

439900 AF-03-AFW-2001-73 VOL Pipe to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 274 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 440000 EB-10-2RI18-S39 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

440200 EB-10-2R117-S39 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

440400 AF-03-AFW-2001-74 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

440500 AF-03-AFW-2001-75 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

I-------------------......------------------ ------------------------------------------------------------------

440600 AF-03-AFW-2001-76 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

440700 AF-03-AFW-2001-77 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

440800 EB-10-H201 VT-3 Component Support Category and item number will be F-A and F1.20A for the 4th interval.

441000 AF-03-AFW-2001-78 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

441100 AF-03-AFW-2001-79 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

441200 AF-03-AFW-2001-80 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

I------- ----------- --------.....

I--------------------------------------- ---------....

DATE: 03/11/02 PAGE: 275 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 441300 AF-03-AFW-2001-81 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

441400 EB-10-H200 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

441600 AF-03-AFW-2001-82 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

441700 AF-03-AFW-2001-83 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

441800 EB-10-2R113-16 VT-3 Component Support Category and item number will be F-A and F1.20A for the 4th interval.

I ------

442000 AF-03-AFW-2001-84 VOL Pipe to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

4 4 2 1 0 0 E B - 1 0 - 2 R 1 1 0 - 1 6 V T - 3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

442300 2-EB-2-7045 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

I- --------------------------------------------

442500 AF-03-AFW-2001-85 VOL Pipe to Pipe Category and item number will be R-A and RI.20 for the 4th interval.

442600 EB-10-2RI07-16 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

I

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS EXAMINATION AREA IDENTIFICATION AF-03-AFW-2001-86 Pipe to Elbow CATEGORY NDE ITEM NO METH VOL FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 3

4 Category and item number will be R-A and R1.20 442900 AF-03-AFW-2001-87 Elbow to Pipe Category and item number will be R-A and R1.20 443000 AF-03-AFW-2001-88 Pipe to Elbow Category and item number will be R-A and R1.20 443100 AF-03-AFW-2001-89 Elbow to Pipe for the 4th interval.

VOL for the 4th interval.

VOL for the 4th interval.

VOL Category and item number will be R-A and R1.20 for the 4th interval.

443200 VT-3 EB-10-2RI04-S38 Component Support Category and item number will be F-A and F1.20A for the 4th interval.

443400 AF-03-AFW-2001-90 VOL Pipe to Pipe Category and item number will be R-A and RI.20 for the 4th interval.

443500 AF-03-AFW-2001-91 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.


I--------------------------------------

443600 AF-03-AFW-2001-92 VOL Elbow to Pipe Category and item numbber will be R-A and RI.20 for the 4th interval.

443700 AF-03-AFW-2001-93 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

I 443800 AF-03-AFW-2001-94 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

SUMMARY

NUMBER 442800 THIRD PERIOD 1

2 3

4 PAGE: 276

DATE: 03/11/02 PAGE: 277 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 443900 AF-03-AFW-2001-95 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

444000 2-EB-1-7044 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

444100 EB-I0-2R99-S38 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

I----------------------

444300 AF-03-AFW-2001-96 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

I------------------------------

444400 AF-03-AFW-2001-97 VOL Pipe to Valve 2AF-218 Category and item number will be R-A and R1.20 for the 4th interval.

444500 Valve 2AF-218 Check Valve No examination required.

444600 AF-03-AFW-2001-98 VOL Valve 2AF-218 to Pipe Category and item number will be R-A and Rl.ll for the 4th interval.

444700 AF-03-AFW-2001-99 VOL Pipe to Branch Connection Category and item number will be R-A and R1.11 for the 4th interval.

Auxiliary Feedwater to Steam Generator B / Dwg. No.

ISI-PRI-2282 447000 Valve 2AF-105 Check Valve No examination required.


I------------------------------------------------------ ----------------------- -----------------------------------

447100 AF-03-AFW-2002-1 VOL Valve 2AF-105 to Pipe Category and item number will be R-A and R1.20 for the 4th interval.


....------- ---------- I------------------------------------------------------------------------------------

I------------------------------

DATE: 03/11/02 PAGE: 278 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 447200 AF-03-AFW-2002-2 VOL X

Pipe to Valve 2AF-45 Category and item number will be R-A and R1.20 for the 4th interval.

447300 Valve 2AF-45 Motor Operated Valve No examination required.

447400 AF-03-AFW-2002-3 VOL Valve 2AF-45 to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

447500 AF-03-AFW-2002-4 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

447600 AF-03-AFW-2002-5 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

447700 AF-03-AFW-2002-6 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

447800 AF-03-AFW-2002-7 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

447900 AF-03-AFW-2002-8 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

I....I........

448000 EB-10-H200 VT-3 X

Component Support Category and item number will be F-A and FI.20A for the 4th interval.

448100 EB-10-H200-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

I.....................-I---------------------------------------...

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 448150 EB-10-S893 CATEGORY NDE ITEM NO METH VT-3 PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 34 1

23 4

Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

448170 EB-10-S893-IWA Welded Attachment VT-).

Category and item number will be C-C and C3.20 for the 4th interval.

448200 VOL AF-03-AFW-2002-9 Pipe to Tee Category and item number will be R-A and R1.20 for the 4th interval.

448300 Valve 2AF-107 Check Valve No examination required.

448400 AF-03-AFW-2002-10 VOL X

Valve 2AF-107 to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

448500 AF-03-AFW-2002-11 VOL Pipe to Valve 2AF-57 Category and item number will be R-A and R1.20 for the 4th interval.

448600 Valve 2AF-57 Motor Operated Valve No examination required.


I----------------------------------------------------

448700 AF-03-AFW-2002-12 VOL Valve 2AF-57 to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

448800 AF-03-AFW-2002-13 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

448900 EB-10-HAA VT-3 Component Support X

Category and item number will be F-A and F1.20A for the 4th interval.

1-------------------------------------------------------------

I...........---------------------------------------------------------------------

THIRD PERIOD 1

2 3

4 PAGE: 279

DATE: 03/11/02 PAGE: 280 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 449000 EB-10-HAA-IWA VT-l Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.


-- ---- -,----I-------------------------------------------------------------------------------------------------

449100 AF-03-AFW-2002-14 VOL Elbow to Pipe Category and item number will be R-A and RI.20 for the 4th interval.

449200 EB-l0-$892 VT-3 X

Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

I---------

449300 AF-03-AFW-2002-15 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

449400 AF-03-AFW-2002-16 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

449500 AF-03-AFW-2002-17 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

I.....---------------------------..--------------------------------------------------

449600 AF-03-AFW-2002-18 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

449700 AF-03-AFW-2002-19 VOL Pipe to Tee Category and item number will be R-A and R1.20 for the 4th interval.

449800 AF-03-AFW-2002-20 VOL Tee to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

449900 AF-03-AFW-2002-21 VOL Elbow to Pipe Category and item number will be R-A and RI.20 for the 4th interval.

DATE: 03/11/02 PAGE: 281 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 450000 AF-03-AFW-2002-22 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

450100 AF-03-AFW-2002-23 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

450200 EB-10-$894 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

450300 EB-10-S894-IWA VT-l Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

Auxiliary Feedwater to Steam Generator B / Dwg.

No. ISI-PRI-2283 451000 AF-03-AFW-2002-24 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

451100 AF-03-AFW-2002-25 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

451200 AF-03-AFW-2002-26 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

451300 AF-03-AFW-2002-27 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

451400 AF-03-AFW-2002-28 VOL Pipe to Flange Category and item number will be R-A and R1.20 for the 4th interval.

451500 AF-03-AFW-2002-29 VOL Flange to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

DATE: 03/11/02 PAGE: 282 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 451600 EB-10-H14 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

I 451700 AF-03-AFW-2002-30 VOL Pipe to Elbow Category and item number will be R-A and RI.20 for the 4th interval.

451800 AF-03-AFW-2002-31 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

..... I---------- -------------------------------------

451900 AF-03-AFW-2002-32 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

I---------------------------------

452000 AF-03-AFW-2002-33 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

452100 EB-10-WEPCO-399 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

452200 EB-10-WEPCO-399-IWA VT-Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

4 5 2 3 0 0 E B - 1 0 - s 9 0 3 V T - 3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

452400 EB-10-S903-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

452500 AF-03-AFW-2002-34 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 283 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 452600 AF-03-AFW-2002-35 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

452700 EB-10-HI6 VT-3 Component Support Category and item number will be F-A and F1.20A for the 4th interval.

452800 EB-10-HI6-IWA VT-l Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

452900 EB-10-s904 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.


--------- I----------------------

453000 EB-10-S904-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

453100 AF-03-AFW-2002-36 VOL Pipe to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

453200 EB-l0-Hl8 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

453300 EB-10-HE9 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

453400 EB-10-HI9-IWA VT-1 Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

453500 AF-03-AFW-2002-37 VOL Pipe to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

DATE: 03/11/02 PAGE: 284 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 453600 EB-10-$776 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

453700 EB-10-S776-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

453800 AF-03-AFW-2002-38 VOL Pipe to Elbow Category and item number will be R-A and RI.20 for the 4th interval.

453900 AF-03-AFW-2002-39 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

454000 EB-10-Sg05 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

454100 EB-10-S905-IWA VT-Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

454200 EB-10-H20 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

454300 AF-03-AFW-2002-40 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

454400 AF-03-AFW-2002-41 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

454500 EB-10-H21 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

DATE: 03/11/02 PAGE: 285 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERN PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 454600 EB-10-H21-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

454700 EB-10-H22 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

454800 EB-10-H22-IWA VT-i Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

454900 EB-10-S906 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

455000 EB-10-S906-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

455100 AF-03-AFW-2002-42 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

455200 AF-03-AFW-2002-43 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

455300 EB-l0-S777 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

455400 EB-10-S777-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

455500 EB-10-H23 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

DATE: 03/11/02 PAGE: 286 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 455600 EB-10-H23-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

455700 AF-03-AFW-2002-44 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

I---------------------------------------------------

455800 AF-03-AFW-2002-45 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

455900 AF-03-AFW-2002-46 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

456000 AF-03-AFW-2002-47 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

456100 AF-03-AFW-2002-48 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

456200 AF-03-AFW-2002-49 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

456300 EB-10-H24 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

456400 EB-10-H24-IWA VT-l Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

456500 AF-03-AFW-2002-50 VOL Pipe to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 287 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 456600 EB-10-H25 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

4 5 67 00 EB H 25 -IWA VT -i Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

456800 EB-10-H26 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

456900 EB-10-H26-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

457000 EB-10-S907 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

457100 EB-10-S907-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.


I-- ---I-----------------------------

I------------------

457200 AF-03-AFW-2002-51 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

I---------------------I--------------------------------------------------------------

4573 00 AF AFW -2002-52 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

1--------------------

457400 AF-03-AFW-2002-53 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

I---------------

.1.....---------------------------------------------

I---------------------------------

457500 AF-03-AFW-2002-54 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 288 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NUE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 457600 AF-03-AFW-2002-55 VOL Pipe to Elbow Category and item number will be R-A and Rl.20 for the 4th interval.

457700 AF-03-AFW-2002-56 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

457800 EB-10-2H32 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

457900 EB-10-2H31 VT-3 Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

I 458000 AF-03-AFW-2002-57 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

I----------------------------------

458100 AF-03-AFW-2002-58 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

458200 EB-10-S908 VT-3 X

Component Support Category and item number will be F-A and FI.20A for the 4th interval.

458300 EB-10-S908-IWA VT-I Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

I.......


...-------------------------------------------------------------------------------- I----------

458400 AF-03-AFW-2002-59 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

458500 AF-03-AFW-2002-60 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

DATE: 03/11/02 PAGE: 289 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 458600 EB-10-2H30 VT-3 X

Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

458700 AF-03-AFW-2002-61 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

I----------------I--------------------------------------------------------

458800 AF-03-AFW-2002-62 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

458900 AF-03-AFW-2002-63 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

I---------------------------------------------------------------------------

459000 AF-03-AFW-2002-64 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

459100 AF-03-AFW-2002-65 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

459200 AF-03-AFW-2002-66 VOL

-X Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

I------------------

459300 AF-03-AFW-2002-67 VOL Pipe to Flued Head Category and item number will be R-A and RI.20 for the 4th interval.

460000 EB-10-AI3 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

460100 EB-10-A I3-IWA VT-l Welded Attachment Category and item number will be C-C and C3.20 for the 4th interval.

DATE: 03/11/02 PAGE: 290 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD SUMMKARY EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 Auxiliary Feedwater to Steam Generator B / Dwg.

No. ISI-PRI-2284 460200 AF-03-AFW-2002-68 VOL Flued Head to Pipe Category and item number will be R-A and RI.20 for the 4th interval.

460300 AF-03-AFW-2002-69 VOL Pipe to Elbow Category and item number will be R-A and RI.20 for the 4th interval.

460400 AF-03-AFW-2002-70 VOL Elbow to Pipe Category and item number will be R-A and RI.20 for the 4th interval.

460500 EB-10-2RI40 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

460700 AF-03-AFW-2002-71 VOL Pipe to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

460800 EB-10-2EB-5 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

461000 EB-10-2R137 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

461200 AF-03-AFW-2002-72 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

461300 AF-03-AFW-2002-73 VOL Elbow to Pipe Category and item number will be R-A and RI.20 for the 4th interval.

I-- - -- -

461400 AF-03-AFW-2002-74 VOL Pipe to Elbow Category and item number will be R-A and RI.20 for the 4th interval.

-- - -- -- -. I- - -

DATE: 03/11/02 PAGE: 291 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 4 6 1 5 0 0 A F - 0 3 -A F W - 2 0 0 2 - 7 5 V O L Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

461600 AF-03-AFW-2002-76 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

461700 AF-03-AFW-2002-77 VOL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

I-------------------

461800 EB-10-2EB-4 VT-3 Component Support Category and item number will be F-A and FI.20A for the 4th interval.

I------------------

I-----------------------------

I------------------------------------------------------

462000 AF-03-AFW-2002-78 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

I-------------------------

462100 AF-03-AFW-2002-79 VOL Elbow to Pipe Category and item number will be R-A and Rl.20 for the 4th interval.

I---------------------------------------------------------------------

462200 EB-10-2EB-3 VT ----

X Component Support Category and item number will be F-A and Fl.20A for the 4th interval.

462400 AF-03-AFW-2002-80 VOL Pipe to Elbow Category and item number will be R-A and R1.20 for the 4th interval.

462500 AF-03-AFW-2002-81 VlL Elbow to Pipe Category and item number will be R-A and R1.20 for the 4th interval.

462600 AF-03-AFW-2002-82 VOL Pipe to Valve 2AF-218 Category and item number will be R-A and RI.20 for the 4th interval.

I----------------------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY NDE ITEM NO METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 34 462700 Valve 2AF-218 Check Valve No examinations required.

462800 AF-03-AFW-2002-83 VOL Valve 2AF-218 to Pipe Category and item number will be R-A and Rl.ll for the 4th interval.

462900 AF-03-AFW-2002-84 VOL X

Pipe to Elbow Category and item number will be R-A and R1.11 for the 4th interval.

463000 AF-03-AFW-2002-85 VOL-X Elbow to Pipe Category and item number will be R-A and R1.11 for the 4th interval.

463100 AF-03-AFW-2002-86 VOL Pipe to Branch Connection Category and item number will be R-A and R1.1l for the 4th interval.

THIRD PERIOD 1

2 3

4 PAGE: 292

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS FIRST PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE NUMBER IDENTIFICATION ITEM NO METH Service Water Supply to Aux FW Pump P-29 / Dwg.

No.

ISI-PRI-2325 PLAN STA SECOND PERIOD O U T A G 1

2 3

4 1

2 3

TUS THIRD PERIOD E

4 1

2 3

4 500000 HB-19-H43 Rigid Support F-A VT-3 Fl.30A 500100 HB-19-H200 F-A VT-3 Component Support F1.30A 500200 HB-19-H44 F-A VT-3 Rigid Support FI.30A 500300 HB-19-S600 F-A VT-3 Component Support F1.30A 500400 JG-4-H37 F-A VT-3 Anchor FI.30B 500500 JG-4-H37-IWA VT-3 Welded Attachment Examination category and item number will become D-A and Dl.20 during fourth interval.

500600 JG-4-5S20 F-A VT-3 Component Support FI.30A Service Water Supply to HX-15D / Dwg. No.

ISI-PRI-2329 501000 H-118 Rigid Support F-A F1.30A VT-3 SHOWN AS A RESTRAINT ON P-215 SHI (8/00) 501200 H-117 F-A VT-3 Rigid Support FI.30A PAGE: 293

DATE: 03/11/02 PAGE: 294 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 501300 A-25 F-A VT-3 Anchor Fl.30B PENETRATION 40 501400 A-25-IWA Welded Attachment PENETRATION 40.

Examination category and item number will become D-A and Dl.20 during fourth interval.


I------

I-------------------------

501600 HB-19 F-A VT-3 Rigid Support Fl.30A Ganged with H200, ISI drawing # should be changed (8/00) 501700 R-219 F-A VT-3 Rigid Support FI.30B GANGED WITH R219 501800 R-218 F-A VT-3 Rigid Support Fl.30B GANGED WITH R218 501900 R-217 F-A VT-3 Rigid Support F1.30B GANGED WITH R217 Service Water Supply to HX-15D / Dwg.

No.

ISI-PRI-2330 502000 R-216 F-A VT-3 Rigid Support FI.30B GANGED WITH R216 502200 R-214 F-A VT-3 Rigid Support Fl.30B GANGED WITH R214 IN A WALL 502300 R-213 F-A VT-3 Rigid Support F1.30B GANGED WITH R213 IN A WALL

DATE: 03/11/02 PAGE: 295 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 502400 A-01D F-A VT-3 X

Anchor Fl.30B GANGED WITH A-04 I---------------------------------

502500 A-01D-IWA X

Welded Attachment GANGED WITH A-04.

Examination category and item number will become D-A and D1.20 during fourth interval.

-I------------------------------------------

502600 HB-21 F-A VT-3 Rigid Support Fl.30A Service Water Supply to HX-15A / Dwg.

No.

ISI-PRI-2331 503000 2H-122 F-A VT-3 Rigid Support Fl.30B SHOWN AS A GUIDE ON P-216 SH2, BASED ON P-314 SH12 IT IS A SUPPORT (8/00) 503100 2H-92 F-A VT-3 Rigid Support Fl.30A I--------------------------....----------------------------------------------------------------

503200 A-19/M82 F-A VT A

Anchor FI.30B PENETRATION 35 I--------------------------------------------------------------------

503300 A-19/M82-IWA Welded Attachment PENETRATION 35.

Examination category and item number will become D-A and D1.20 during fourth interval.

503400 R-192 F-A VT-3 Rigid Support FI.30B GANGED WITH R192

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION Service Water SuDDly to HX-15A /

Dwg.

No.

CATEGORY ITEM NO ISI-PRI-2332 NDE METH PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 34 1

2 34 503500 HB-19-RI91 Rigid Support F-A Fl. 3 OA VT-3 GANGED WITH R191 503700 HB-19-RI88 F-A VT-3 Restraint FI.30B GANGED WITH R188 IN A FLOOR 503800 HB-19-R187 F-A VT-3 Rigid Support FI.30A GANGED WITH R187 503900 HB-19-R186 F-A VT-3 Rigid Support FI.30A GANGED WITH R186, BEST SUPPORT DRAWING IN WALKDOWN WE-200089 504000 HB-19-RI85 F-A VT-3 Rigid Support F1.30B GANGED WITH R185 504200 HB-19-RI81 F-A VT-3 X

Restraint FI.30B GANGED WITH RI18 IN A FLOOR 504400 HB-19-A2 F-A VT-3 X

Anchor Fl.30B This anchor is listed as HB-19-A2 on plant controlled drawings, gang hanger with A2 504500 HB-19-A2-IWA X

Welded Attachment This anchor is listed as HB-19-A2 on plant controlled drawings, gang hanger with A2.

Examination category and item number will become D-A and D1.20 during fourth interval.

.......I.--.--.----------.-.-------.--.-------------.--.--.---.---.....................---

504700 HB-19-SA-1 F-A VT-3 Support Fl.30B THIRD PERIOD 1

2 3

4 PAGE: 296

DATE: 03/11/02 PAGE: 297 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 Service Water Supply to HX-15A / Dwg. No.

ISI-PRI-2332 504800 HB-19-SA-2 F-A VT-3 Support Fl.30B Service Water Supply to HX-15C / Dwg.

No.

ISI-PRI-2333 506000 2H-116 F-A VT-3 X

Rigid Support F1.30A 506300 2H-115 F-A VT-3 X

Rigid Support F1.30A 506350 2H-115-IWA X

Welded Attachment Examination category and item number will become D-A and D1.20 during fourth interval.

506400 A-24/M82 F-A VT-3 Anchor Fl.30B PENETRATION 36 506500 A-24/M82-IWA Welded Attachment PENETRATION 36.

Examination category and item number will become D-A and D1.20 during fourth interval.

Service Water Supply to HX-15C / Dwg.

No. ISI-PRI-2334 507000 R-210 F-A VT-3 Rigid Support Fl.30A GANGED WITH R210 I-----------------------------------------------

I--------

507100 R-209 F-A VT-3 Rigid Support FI.30B GANGED WITH R209

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS CATEGORY ITEM NO F-A Fl.30A StUMMARY EXAMINATION AREA NUMBER IDENTIFICATION 507200 R-208 Rigid Support GANGED WITH R208 507300 R-207 Rigid Support NDE METH VT-3 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

F-A VT-3 Fl.30B GANGED WITH R207 507400 R-206 F-A VT-3 Rigid Support FI.30A GANGED WITH R206 507500 R-205 Rigid Support GANGED WITH R205 507600 A-03C Anchor F-A VT-3 Fl. 3 OB F-A VT-3 F1.30B GANGED WITH A3 507700 A-03C-IWA Welded Attachment GANGED WITH A3, Examination category and item number will become D-A and Dl.20 during fourth interval.

507800 HB-16 F-A Rigid Support FI.30A VT-3 Service Water Supply to HX-15B / Dwg.

No.

ISI-PRI-2335 508000 HB-19-RI97 Rigid Support F-A FI.30B vT-3 X

GANGED WITH R197 508100 HB-19-R196 F-A VT-3 Rigid Support F1.30B GANGED WITH R196 PAGE: 298 THIRD PERIOD 1

2 3

4

DATE: 03/11/02 PAGE: 299 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 508400 HB-19-A2 F-A VT-3 Anchor FI.30B Ganged with HB-19-Al.

508500 HB-19-A2-IWA D-B VT-3 Welded Attachment D2.20 I-- --I..............................-----.---- ------

-.I.--

508700 HB-19-SB-l F-A VT-3 Support FI.30B 508800 HB-19-S-2 F-A VT-3 Support F1.30B Service Water Supply to HX-15B / Dwg.

No. ISI-PRI-2336 509000 H-50 F-A VT-3 Rigid Support F1.30A NOT VERIFIED THAT IT EXISTS (DOES NOT SHOW ON P-215 SKI)

(8/00) 509100 A-21 F-A VT-3 Anchor F1.30B PENETRATION 39 509200 A-210-IWA Welded Attachment PENETRATION 39, Category and item number will be D-A and DI.20.

509300 R-200 F-A VT-3 Rigid Support FI.30B GANGED WITH R200 509400 R-199 F-A VT-3 Rigid Support FI.30B GANGED WITH R199 509500 R-198 F-A VT-3 Rigid Support Fl.30B GANGED WITH R198 I...........---------------------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY NDE ITEM NO METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND THIRD PERIOD PERIOD OUTAGE 1

2 3

4 1

2 3

4 Service Water Supply to HX-15B / Dwg.

No.

ISI-PRI-2337 510000 H-109 Rigid Support F-A 510100 H-125 Rigid Support 510200 H-124 Rigid Support VT-3 Fl.30A F-A VT-3 Fl. 30B SHOWN AS A GUIDE ON P-215 SHI (8/00)

Discharge from Aux FW Pump 2P-29 / Dwg.

No.

ISI-PRI-2338 511000 Hi9 Pipe Hanger F-A Fl.30A VT-3 Component will be exempt for the fourth interval.

511100 2H5 F-A VT-3 X

Rigid Support Fl.30B Component will be exempt for the fourth interval.

I--------------I----------------------

511150 2H5-IWA X

Welded Attachment Component will be exempt for the fourth interval.

S I

511200 H18 F-A VT-3 Rigid Support Fl.30A Component will be exempt for the fourth interval.

511300 2H4A F-A VT-3 Rigid Support Fl.30B Component will be exempt for the fourth interval.

51 F-A 511400 2111 F-A vT-3 E

Rigid Support Fl.30A Component will be exempt for the fourth interval.

F-A Fl.30A VT-3 PAGE: 300

DATE: 03/11/02 PAGE: 301 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 511500 2H2 F-A VT-3 Rigid Support FI.30B Component will be exempt for the fourth interval.

Service Water Return from HX-15A / Dwg.

No.

ISI-PRI-2344 512000 HB-19-SA-4 F-A VT-3 Support F1.30B 512100 HB-19-SA-3 F-A VT-3 512100 HB-19-SA T

Support F1.30B 512200 HB-19-SA-5 F-A VT-3 Support FI.30B Gan hagerwitF-A2A ndT-02 512300 HB-19-A2 D-B VT-3 Anchor F1.30A Gang hanger with A-02A and A-02B 512400 HB-19-A2-IWA F-B VT-3 Welded Attachment D2.20 Gang hanger with A-02A and A-02B I-------------------------

I------------------------------

512500 HB-19-R185 F-A VT-3 Restraint F1.30B GANGED WITH R181 IN A FLOOR 512600 HB-19-RI85 F-A VT-3 Rigid Support Fl.30B GANGED WITH R185 512700 HB-19-RI8 F-A VT-3 Rigid Support FI.30B GANGED WITH R18i, BEST SUPPORT DRAWING IN WAIJDOWN WE-200089 I

512800 HB-19-RlB7 F-A VT-3 Rigid Support Fl.30B GANGED WITH R187

DATE: 03/11/02 PAGE: 302 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 512900 HB-19-RI88 Restraint CATEGORY ITEM NO F-A Fl.30B GANGED WITH R188 IN A FLOOR 513000 HB-19-RI91 F-A Rigid Support FI.30B NDE METH VT-3 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

VT-3 GANGED WITH R19i 513100 HB-19-Ri92 Rigid Support F-A VT-3 Fl.30B GANGED WITH R192 513200 HB-19-A20 F-A VT-3 Anchor Fl.30B Penetration 43, Flued Head Service Water Return from HX-15A / Dwg. No.

ISI-PRI-2345 514200 HB-19-2H121 Rigid Support F-A FI.30B VT-3 514300 HB-19-$573 F-A VT-3 Rigid Support F1.30B P-213 SHOWS H127 FLIPPED WITH S573, 79-14 WALKDOWN CORRECTED THIS BUT REVISED YET (8/00) 514400 HB-19-HI27 F-A VT-3 Rigid Support F1.30B 514500 HB-19-HI19 Rigid Support Ganged with HIl9A and HI11B 514600 HB-19-HI20 Rigid Support F-A FI.30B F-A FI.30B THE DRAWING HAS NOT BEEN VT-3 VT-3 Ganged with H120A and H120B THIRD PERIOD 1

2 3

4

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 514700 HB-19-HI02 Rigid Support CATEGORY ITEM NO F-A FI.30B NDE METH VT-3 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND THIRD PERIOD PERIOD OUTAGE 1

2 34 1

23 4

X Gang support with ISI-PRI-2347, H102A.

They are scheduled together.

514800 HB-19-5547 F-A VT-3 Rigid Support Fl.30B Gang support with ISI-PRI-2347, S547A and ISI-PRI-2351,

$547B.

They are scheduled together.

514900 HB-19-S547-IWA VT-I-------------X Welded Attachment Examination category and item number will become D-A and D1.20 during fourth interval.

Service Water Return from HX-15B / Dwg.

No. ISI-PRI-2346 516020 HB-19-SB-6 Support F-A Fl.30B VT-3 516040 HB-19-SB-3 F-A VT-3 Support Fl.30B 516060 HB-19-SB-5 F-A Support VT-3 Fl.3 OB 516080 HB-19-SB-4 F-A VT-3 Support Fl.30B 516100 HB-19-Al F-A VT-3 Anchor FI.30B This anchor is listed as HB-19-A-l on plant controlled drawings, gang hanger with A-02B 516200 EB-19-Al-IWA D-B VT-3 Welded Attachment D2.20 This anchor is listed as HB-19-A-l on plant controlled drawings, gang hanger with A-02B 516300 HB-19-R196 F-A VT-3 Rigid Support Fl.30B GANGED WITH R136 PAGE: 303

DATE: 03/i1/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS

SUMMARY

NUMBER 516400 EXAMINATION AREA IDENTIFICATION HB-19-RI97 Rigid Support GANGED WITH R197 516500 HB-19-R198 Rigid Support CATEGORY NDE ITEM NO METH F-A VT-3 FI.30B F-A VT-3 F1.30B PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 34 1

23 4

GANGED WITH R198 516600 HB-19-R199 Rigid Support GANGED WITH R199 516700 HB-19-R200 Rigid Support GANGED WITH R200 516800 HB-19-R202 Restraint GANGED WITH R201 IN A FLOOR 518000 HB-19-A22 Anchor F-A VT-3 FI.30B F-A Fl. 3GB F-A FP.3 0B VT-3 VT-3 PENETRATION 47 Service Water Return from HX-15B /

Dwg.

No. ISI-PRI-2347 518200 HB-19-2H119 F-A VT-3 Rigid Support Fl.30B Ganged with H119 and H119B 518300 HB-19-H120 Rigid Support F-A VT-3 Fl.3 OB Ganged with H120 and H120B 518400 HB-19-HI02 F-A VT-3 X

Pipe Hanger F1.30B Gang support with ISI-PRI-2345, H102.

They are scheduled together.

518500 HB-19-S547 F-A VT-3 Rigid Support F1.30A X

Gang support with ISI-PRI-2345, S547 and ISI-PRI-2351, 5547B.

They are scheduled together.

THIRD PERIOD 1

2 3

4 F-A F1.30B VT-3 PAGE: 304

DATE: 03/11/02 PAGE: 305 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 Service Water Return from HX-15B / Dwg.

No.

518550 HB-19-S547-IWA Welded Attachment Examination category and item number will become D-A and Dl.20 during fourth interval.

Service Water Return from HX-15B / Dwg.

No.

ISI-PRI-2347 518600 HB-19 A F-A VT-3 Rigid Support FI.30A ADDED AFTER REVIEWING THE 79-14 WALKDOWN 7/00 I--------------------------......----------------------------------------

Service Water Return from HX-15C / Dwg. No.

ISI-PRI-2348 519000 HB-15 F-A VT-3 Rigid Support Fl.30B 519100 A3 F-A VT-3 Anchor FI.30B GANGED WITH A-03C 519200 A3-IWA Welded Attachment GANGED WITH A-03C.

Examination category and item number will become D-A and D1.20 during fourth interval.

I-----------------------------------------------------------------------

519300 R205 F-A VT-3 Rigid Support Fl.30B GANGED WITH R205 I----------

519400 R206 F-A VT-3 Rigid Support Fl.30B GANGED WITH R206 519500 R207 F-A VT-3 Rigid Support F1.30B GANGED WITH R207 I----------I------------------.............I-----------------------------------------------------------------

519600 R208 F-A VT-3 Rigid Support F1.30B GANGED WITH R208

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS EXAMINATION AREA IDENTIFICATION R209 Rigid Support CATEGORY NDE ITEM NO METH F-A VT-3 F1.30B FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

GANGED WITH R209


I-----

519800 R210 F-A VT-3 Rigid Support FI.30B GANGED WITH R210 I----------------------------------

519900 A32 F-A VT-3 Anchor Fl.30B SHOWN ON P-213 AS A-27(A DCN HAS BEEN WRITTEN) (7/00)


I--------------------------------------

520000 A32-IWA Welded Attachment SHOWN ON P-213 AS A-27(A DCN HAS BEEN WRITTEN) (7/00) 520100 H201 F-A VT-3 Rigid Support Fl.30A X

520200 HB-19-H201-IWA MT Welded Attachment Examination category and item number will become D-A and Dl.20 during fourth interval.

Servi e Service Water Return from HX-15C / Dwg. No. ISI-PRI-2349 521000 H112 Rigid Support F-A VT-3 X

Fl.30B GANGED WITH ONE PIPE 521100 HE13 F-A VT-3 Rigid Support Fl.30A 5 2 1 2 0 0 S 5 6 9 F - A V T - 3 Rigid Support FI.30B SHOWN AS A RESTRAINT ON P-213 (7/00) 521300 S570 F-A VT-3 Rigid Support F1.30B SHOWN AS A RESTRAINT ON P-213(7/00),

GANGED WITH OTHER PIPES I---------------------------------------------------------------- ------------------------ ------------------------------- ----------............

SUMMARY

NUMBER 519700 PAGE: 306 THIRD PERIOD 1

2 3

4

DATE: 03/11/02 PAGE: 307 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 521400 H107 F-A VT-3 Rigid Support FI.30B 521500 S546 F-A VT-3 Rigid Support F1.30B SHOWN AS A RESTRAINT ON P-213(7/00)

Service Water Return from HX-15D /

Dwg.

No.

ISI-PRI-2350 522000 HB20 F-A VT-3 Rigid Support Fl.30B 522100 A4 F-A VT-3 Anchor Fl.30B GANGED WITH A-01D


I---------

522200 A4-IWA Welded Attachment Ganged with A-01D.

Examination category and item number will become D-A and Dl.20 during fourth interval.

522300 R213 F-A VT-3 Rigid Support FI.30B GANGED WITH R213 IN A WALL 522400 R214 F-A VT-3 Rigid Support Fl.30B GANGED WITH R214 IN A WALL I------------

522500 R216 F-A VT-3 Rigid Support FI.30B GANGED WITH R216 522600 R217 F-A VT-3 Rigid Support Fl.30B GANGED WITH R217 I------I------------------------------------

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS FIRST PERIOD

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION CATEGORY NDE PLAN STATUS SECOND PERIOD OUTAGE ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 Service Water Return from HX-15D / Dwg.

No.

ISI-PRI-2351 F-A F1.30B 523000 R218 Rigid Support GANGED WITH R218 523100 R219 Rigid Support GANGED WITH R219 523200 H200 Rigid Support VT-3 F-A VT-3 F1.3DB F-A VT-3 Fl.30B Ganged with HB-19 (DCN WILL BE WRITTEN TO CHANGE HB-19 TO HB-19 H200 (8/00))

523300 R220 F-A VT-3 Rigid Support FI.30B GANGED WITH R220 523400

" A26 F-A VT-3 Anchor Fl.30B PENETRATION 48 523500 A26-IWA Welded Attachment PENETRATION 48.

Examination category and item number will become D-A and D1.20 during fourth interval.

523600 H119B F-A VT-3 Pipe Support Fl.30A Ganged with H119 and HI11A 523700 H120B F-A VT-3 Rigid Support FI.30B Ganged with H120A and H120 523800 HI01 F-A VT-3 Pipe Support Fl.30A THIRD PERIOD PAGE: 308

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 3 COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 523900 S547B CATEGORY NDE ITEM NO METH VT-3 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

23 4

X Rigid Support Gang support with ISI-PRI-2345, S547 and ISI-PRI-2347,

$547A.

They are scheduled together.

Service Water Return from HX-15D / Dwg.

No.

524000 HB-19-S547-IWA Welded Attachment Examination category and item number will become D-A and Dl.20 during fourth interval.

PAGE: 309 THIRD PERIOD 1

2 3

4

POINT BEACH NUCLEAR PLANT - UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS P COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD SUMO4ARY EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 Pressure Test / Dwg. No.

700100 2-PT-AF-I P

VT-2 X

X X

Auxiliary Feedwater Callup AFW-2PT-l (still needs to be generated).

General area is from the outboard isolations through penetrations 5 and 6, to steam generators 2HX-IA and 2HX-lB.

700200 2-PT-AF-2 P

VT-2 X

X Auxiliary Feedwater Callup AFW-2PT-2.

General area is from 2P-29 TDAFWP to Outboard Isolation valves 106 and 107.

Examination to be performed during the week of February 4,2002.

Need insulation removed from valve.

I------------------------------------------------

700300 2-PT-CS-I P

VT-2 X

X H

Containment Spray Callup CS-2PT-I.

General area is from the Cl break at the whip restraint, through Penetrations 3 and 4, out to the Inboard isolation check and bypass.

700400 2-PT-CC-I P

VT-2 X

X X

Component Cooling Callup CC-2PT-l.

General area is from Tank 2T-12 through P-IIA/B, heat exchangers, through penetrations, to heat exchangers.

I--------------------------------

701000 2-PT-MS-1 P

VT-2 X

H H

Main Steam Outside Containment Callup MS-2PT-I.

General area is from C1 break to penetrations 1 and 2 and MS-2019 and MS-2020.

701100 2-PT-MS-2 P

VT-2 X

Main Steam Inside Containment Callup MS-2PT-2.

General area is penetrations 1 and 2 to steam generators 2HX-lA and 2HX-IB.

I---------------------------------------

701500 2-PT-RH-i P

VT-2 X

X X

Residual Heat Removal Inside/Outside Con Callup RH-2PT-I.

General area is from PlOA/B through heat exchangers to the inboard isolation valves.

701700 2-PT-SI-1 P

VT-2 X

X Safety Injection Outside Containment Callup SI-2PT-I.

General area is around pumps P-14A and P-14B.

PAGE: 310 DATE: 03/11/02

POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS P COMPONENTS EXAMINATION AREA IDENTIFI CATION CATEGORY NDE ITEM NO METH FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND THIRD PERIOD PERIOD OUTAGE 1

23 4

1 23 4

701800 2-PT-SI-2 Safety Injection Outside Containment VT-2 X

X X

Callup SI-2PT-2.

General area is the safety injection eductor piping.

701900 2-PT-SI-3 P

VT-2 X

X Safety Injection Outside Containment X

Callup SI-2PT-3.

General area is RWST to boundary valves.

702000 2-PT-SI-4 P

VT-2 X

X X

Safety Injection A Train Outside Contain Callup SI-2PT-4.

General area is safety injection A train outside containment and recirculation.

702100 2-PT-SI'5 P

VT-2 X

X X

Safety Injection B Train Outside Contain Callup SI-2PT-5.

General area is safety injection B train outside containment and recirculation.

702200 2-PT-SI-6 P

VT-2 X

X X

Safety Injection A/B Inside/Outside Cont Callup SI-2PT-6.

General area is near the Accumulators inside containment.

702300 2-PT-SI-7 P

VT-2 X

X X

Safety Injection Spray Additive Tank Callup SI-2PT-7.

General area is the NaOH tank.

I-----

702400 2-PT-SI-8 P

VT-2 X

X X

Safety Injection Event V RCS Check Valve Callup SI-2PT-l.

703000 2-PT-SW-i P

VT-2 X

X X

Service Water Inside Containment Callup SW-2PT-1.

703100 2-PT-CV-1 P

VT-2 X

X CVCS Inside/Outside Containment Callup CV-2PT-I.

I-----------

DATE: 03/11/02

SUMMARY

NUMBER PAGE: 311

PAGE: 312 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS P COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 703200 2-PT-CV-2 CVCS Outside Containment CATEGORY NDE ITEM NO METH p

VT-2 PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 34 1

23 4

X X

Callup CV-2PT-2.

705100 IT-536 Containment Sump Callup O-IT-536, performed 2SI-851A/B.

705200 SEM 7.11.6 RCS System Leakage Test P

VT-2 X

X X

every 18 months.

General area is from valves 2SI-85OA/B to valves P

VT-2 X

A -

To be performed during startup at the end of the outage in conjunction with IT-235.

I ----- I---------------------------------------------------------

THIRD PERIOD 1

2 3

4 X

DATE: 03/11/02 PAGE: 313 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4

/ Dwg.

No.

710000 2TS-36 p

VT-2 Penetration Pressure Test Callup RH-2PT-2.

General area is penetrations V-I and V-2.

710100 2TS-38 P

vT-2 Containment Spray Pressure Test No Callup:

General area is the containment spray headers inside containment.

This is a flow test to determine the system is open.

I-----------------------------------------------------------------------------------------------------

7 2 0 0 00 2 OR T -2 5 j

V T -2 Penetration Pressure Test Callup O-RT-25.

General area is penetration P-9.

I----------------

720100 20RT-30 J

VT-2 Penetration Pressure Test Callup O-RT-30.

General area is penetration P-12C.

720200 2ORT-31 VT-2 Penetration Pressure Test Callup O-RT-31.

General area is penetration P-14A.

I--

720300 20RT -33 VT -2 Penetration Pressure Test Callup O-RT-633.

General area is P-42C.

I---------------------------------------------------------------------- ----------------------------

720400 20RT-42 J

VT-2 Penetration Pressure Test Callup O-RT-42.

General area is penetration P-30C.

I------------------------------------------------------ --------------------------------

720500 20RT-43 J

VT-2 Penetration Pressure Test Callup O-RT-43.

General area is P-31B.

720600 20RT-44 VT-2 Penetration Pressure Test Callup 0-RT-44.

General area is P-31C.

DATE: 03/11/02 PAGE: 314 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 720700 2ORT-47 J

VT-2 Penetration Pressure Test Callup O-RT-47.

General area is penetration P-33A.

720800 20RT-48 J

VT -2 Penetration Pressure Test Callup O-RT-48.

General area is penetration P-33B.

720900 2ORT-49 J

VT-2 Penetration Pressure Test Callup O-RT-49.

General area is penetration P-33C.

721000 20RT-50 J

VT-2 Penetration Pressure Test Callup O-RT-50.

General area is penetration P-34A.

721100 2ORT-53 J

VT-2 Penetration Pressure Test Callup O-RT-53.

General area is Penetration P-34D.

721200 2ORT-61 J

VT-2 Penetration Pressure Test Callup O-RT-61.

General area is penetration P-71.

I-----------------------------

721300 20RT-64 J

VT-2 Penetration Pressure Test Callup O-RT-64.

General area is penetration X-1.

I---------

I-------------------------------------------------------.......---------

721400 20RT-65 J

VT-2 Penetration Pressure Test Callup O-RT-65.

General area is penetration X-1.

I---------------------------------------------------------- ----------------------------- ----------------------------------------------

721500 2ORT-66A J

VT-2 Penetration Pressure Test Callup O-RT-66A.

General area is penetration P-31A.

721600 2ORT-66B J

VT-2 Penetration Pressure Test Callup O-RT-66B.

General area is penetration P-14B.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS COMPONENTS SUMMhARY EXAMINATION AREA NUMBER IDENTIFICATION 721700 20RT-66C Penetration Pressure Test CATEGORY NDE ITEM NO METH J

VT-2 PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

2 34 1

23 4

Callup O-RT-66C.

General area is penetration P-32A.

I------------------------------- --------------- ------------------------------ ------------------------------------------------------------------

725000 Containment Walkdown VT X

X X

X X

Information Only Information walkdown of the containment as the outage is beginning to look for leakage on components where work orders have not been written.

This is an augmented examination performed at the request of the plant.

Callup 2-RC-LT-INFO.

PAGE: 315 THIRD PERIOD 1

2 34

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS N COMPONENTS FIRST PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 Pressurizer Safety and Relief Valve Discharge / Dwg.

No.

0870 005-002 sh. 1 PLAN STATUS SECOND PERIOD OUTAGE 1

2 34 800000 HS-29 Snubber 800100 HS-30 Snubber 800200 HS-601R-37 Snubber Listed on drawing as RC-601R-2-HS37.

800300 HS-601R-93 AUG AUG AUG AUG Snubber Listed on drawing as RC-601R-2-HS93.

800400 HS-601R-95B AUG Snubber Listed on drawing as RC-601R-2-HS95B.

RPV Head Lift Rig /

Dwg. No.

ISI-PRI-2401 AUG 801000 RPV-HLR-01 Clevis Plate to Leg Weld Not an ASME Section XI item.

801100 RPV-HLR-02 AUG Clevis Plate to Leg Weld Not an ASME Section XI item.

801200 RPV-HLR-03 AUG Clevis Plate to Leg Weld Not an ASME Section XI item.

801300 RPV-HLR-04 AUG Ring Gird-Support Lug Weld SUR SUR SUR SUR Not an ASME Section XI item.

THIRD PERIOD 1

2 3

4 PAGE: 316

DATE: 03/11/02 PAGE: 317 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS N COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 34 801400 RPV-HLR-05 AUG SUR Ring Gird-Support Lug Weld Not an ASME Section XI item.

801500 RPV-HLR-06 AUG SUR Ring Gird-Support Lug Weld Not an ASME Section XI item.

I------------------------------------

801600 RPV-HLR-07 AUG SUR Side Lug-Sling Assy Link Weld Not an ASME Section XI item.

801700 RPV-HLR-08 AUG SUR Side Lug-Sling Assy Link Weld Not an ASME Section XI item.

801800 RPV-HLR-09 AUG SUR B..

Side Lug-Sling Assy Link Weld Not an ASME Section XI item.

RPV Internals Lift Rig / Dwg.

No.

ISI-PRI-2402 802000 RPV-ILR-01 AUG SUR Leg Assembly to Adapter Weld Not an ASME Section XI item.

802100 RPV-ILR-02 AUG SUR Leg Assembly to Adapter Weld Not an ASME Section XI item.

802200 RPV-ILR-03 AUG SUR Leg Assembly to Adapter Weld Not an ASME Section XI item.

802300 RPV-ILR-04 AUG SUR Leg Assembly to Adapter Weld Not an ASME Section XI item.

802400 RPV-ILR-05 AUG SUR Leg Assembly to Adapter Weld Not an ASME Section XI item.

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS N COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 802500 RPV-ILR-06 Leg Assembly to Adapter Weld CATEGORY ITEM NO AUG NDE METH SUR PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD OUTAGE 1

23 4

12 34 1

23 4

Not an ASME Section XI item.

802600 RPV-ILR-07 Sling Leg-Adapter Weld Not an ASME Section XI item.

802700 RPV-ILR-08 Sling Leg-Adapter Weld AUG SUR AUG SUR Not an ASME Section XI item.

802800 RPV-ILR-09 AUG SUR Sling Leg-Adapter Weld Not an ASME Section XI item.

802900 RPV-ILR-10 AUG Sling Leg-Adapter Weld Not an ASME Section XI item.

803000 RPV-ILR-11 AUG Sling Leg-Adapter Weld SUR SUR Not an ASME Section XI item.

803100 RPV-ILR-12 AUG SUR Sling Leg-Adapter Weld Not an ASME Section XI item.

803200 RPV-ILR-13 Spreader Assembly Weld AUG SUR Not an ASME Section XI item.

803300 RPV-ILR-14 AUG SUR Spreader Assembly Weld Not an ASME Section XI item.

803400 RPV-ILR-15 AUG SUR Spreader Assembly Weld Not an ASME Section XI item.

PAGE: 318

PAGE: 319 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS N COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION 803500 RPV-ILR-16 Sling Lug-Block Weld CATEGORY ITEM NO AUG NDE METH SUR FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 34 Not an ASME Section XI item.

803600 RPV-ILR-17 Sling Lug-Block Weld Not an ASME Section XI item.

803700 RPV-ILR-18 Sling Lug-Block Weld Not an ASME Section XI item.

803800 RPV-ILR-19 Top Lug-Sling Block Weld Not an ASME Section XI item.

803900 RPV-ILR-20 Top Lug-Sling Block Weld AUG SUR AUG SUR AUG SUR AUG SUR Not an ASME Section XI item.

RC Pump Motor Lift Rig / Dwg.

No.

ISI-PRI-2403 805000 RCP-LR-01 Lift Rig Spreader Assembly Weld AUG NOT AN ASME SECTION XI EXAM.

805100 RCP-LR-02 AUG Lift Rig Spreader Assembly Weld NOT AN ASME SECTION XI EXAM.

805200 RCP-LR-03 AUG SUR Lift Rig Spreader Assembly Weld NOT AN ASME SECTION XI EXAM.

S------------------------------------------

Reactor Pressure Vessel Closure Head Bolting/CRD / Dwg. No. ISI-PRI-2103 AUG 805300 RPV-HLUG-01 RPV Head Lifting Lug SUR LUG IS NOT UNDER CONSTANT LOAD.

ADDED TO PROGRAM AS AUGMENTED EXAM.

I-------------------------

THIRD PERIOD 1

2 3

4

DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS N COMPONENTS

SUMMARY

EXAMINATION AREA NUMBER IDENTIFICATION Reactor Pressure Vessel Closure Head / Dwg.

CATEGORY NDE ITEM NO METH No.

ISI-PRI-2103 PLAN STATUS FIRST SECOND PERIOD PERIOD OUTAGE 1

23 4

1 23 4

AUG 805400 RPV-HLUG-02 RPV Head Lifting Lug SUR Lug is not under constant load.

805500 RPV-HLUG-03 AUG SUR RPV Head Lifting Lug LUG IS NOT UNDER CONSTANT LOAD.

ADDED TO PROGRAM AS AUGMENTED EXAM.

RC Pump Motor Flywheel / Dwg.

No.

ISI-PRI-2404 806100 RCP A Flywheel RC Pump Flywheel RGI. 14 SUR VOL NOT AN ASME SECTION XI EXAM.

806300 RCP B Flywheel RGl.14 RC Pump Flywheel SUR VOL NOT AN ASME SECTION XI EXAM.

Main Steam Bypass Energy Absorbers / Dwg.

No.

ISI-PRI-2405 807000 EA-EB-2-1 Energy Absorber AUG VT-3 Not a Section XI examination.

To be examined for cracking.

determine if any unanticipated loadings may have occured.

807100 EA-EB-2-3 AUG VT-3 Energy Absorber Scratch plates will be examined to Not a Section XI examination.

To be examined for cracking.

Scratch plates will be examined to determine if any unanticipated loadings may have occured.

807200 EA-EB-2-4 AUG VT-3 Energy Absorber Not a Section XI examination.

To be examined for cracking.

determine if any unanticipated loadings may have occured.

807300 EA-EB-2-5 AUG VT-3 Energy Absorber Not a Section XI examination.

To be examined for cracking.

determine if any unanticipated loadings may have occured.

Scratch plates will be examined to Scratch plates will be examined to THIRD PERIOD 1

2 3

4 PAGE: 320

PAGE: 321 DATE: 03/11/02 POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS N COMPONENTS EXAMINATION AREA IDENTIFICATION EA-EB-2-6 Energy Absorber CATEGORY ITEM NO AUG NDE METH VT-3 FIRST PERIOD 1

2 3

4 PLAN STATUS SECOND PERIOD OUTAGE 1

2 3

4 Not a Section XI examination.

To be examined for cracking.

Scratch plates will be examined to determine if any unanticipated loadings may have occured.

SUMMARY

NUMBER 807400 THIRD PERIOD 1

2 3

4

POINT BEACH NUCLEAR PLANT -

UNIT 2 INSERVICE INSPECTION LONG TERM PLAN CLASS 2 COMPONENTS PLAN STATUS FIRST SECOND THIRD PERIOD PERIOD PERIOD

SUMMARY

EXAMINATION AREA CATEGORY NDE 0 U T A G E NUMBER IDENTIFICATION ITEM NO METH 1

2 3

4 1

2 3

4 1

2 3

4 Safety Injection A Accumulator Nozzles / Dwg.

No.

N/A 810000 SI-832A-NOZ IN91-05 VOL SI Accumulator A Nozzle NOZ Cal Block:

23-PTB Callup ISI-2P34A.

Component to be examined once per interval in accordance with Information Notice 91-05.

810100 SI-832B-NOZ IN91-05 VOL SI Accumulator A Nozzle NOZ Cal Block:

23-PTB Callup ISI-2P34A.

Component to be examined once per interval in accordance with Information Notice 91-05.

810200 SI-832C-NOZ IN91-05 VOL SI Accumulator A Nozzle NOZ Cal Block:

23-PTB Callup ISI-2P34A.

Component to be examined once per interval in accordance with Information Notice 91-05.

810300 SI-832D-NOZ IN91-05 VOL SI Accumulator A Nozzle NOZ Cal Block:

23-PTB Callup ISI-2P34A.

Component to be examined once per interval in accordance with Information Notice 91-05.

Safety Injection B Accumulator Nozzles / Dwg.

No.

N/A 810400 SI-833A-NOZ IN91-05 VOL SI Accumulator B Nozzle NOZ Cal Block:

23-PTB Callup ISI-2P34B.

Component to be examined once per interval in accordance with Information Notice 91-05.

810500 SI-833B-NOZ IN91-05 VOL SI Accumulator B Nozzle NOZ Cal Block:

23-PTB Callup ISI-2P34B.

Component to be examined once per interval in accordance with Information Notice 91-05.

810600 SI-833C-NOZ IN91-05 VOL SI Accumulator B Nozzle NOZ Cal Block:

23-PTB Callup ISI-2P34B.

Component to be examined once per interval in accordance with Information Notice 91-05.

810700 SI-833D-NOZ IN91-05 VOL SI Accumulator B Nozzle NOZ Cal Block:

23-PTB Callup ISI-2P34B.

Component to be examined once per interval in accordance with Information Notice 91-05.

DATE: 03/11/02 PAGE: 322