TSTF-419 (WOG-154, Rev. 0)
NUREGs Affected:
Revise PTLR Definition and References in ISTS 5.6.6, RCS PTLR Industry/TSTF Standard Technical Specification Change Traveler 1430 1431 1432 1433 1434 Classification:
- 1) Technical Change Priority 3)Low
==
Description:==
The definition of PRESSURE AND TEMPERATURE LIMITS REPORT (PTLR) is revised to delete the reference to the Specifications containing the limits specified in the PTLR.
The requirement in ITS 5.6.6, Reactor Coolant System (RCS) PRESSURE AND TEMPERATURE LIMITS REPORT (PTLR), to identify the NRC staff approval document by date is revised to allow the Topical Report(s) to be identified by number and title. A requirement is added to the Reviewers Note to specify the complete citation in the PTLR for each Topical Report, include the report number, title, revision, date, and any supplements.
Justification:
BACKGROUND NRC Generic Letter 96-06, Relocation of the Pressure Temperature Limit Curves and Low Temperature Overpressure Protection System Limits, dated January 31, 1996, allows licensees to relocate the pressure temperature (P/T) limit curves from their plant technical specifications (TS) to a pressure temperature limits report (PTLR) or a similar document. The Low Temperature Overpressure Protection (LTOP) System limits were also allowed to be relocated to the same document. The methodology used to determine the P/T and LTOP System limit parameters must comply with the specific requirements of Appendices G and H to Part 50 of Title 10 of the Code of Federal Regulations (10 CFR), be documented in an NRC approved topical report or in a plant-specific submittal, and be incorporated by reference into the TS. Subsequent changes in the methodology must be approved by a license amendment.
Similar changes to NUREG-1432, Rev. 2, are addressed in TSTF-408.
PROPOSED CHANGE 1.
The definition of PRESSURE AND TEMPERATURE LIMITS REPORT (PTLR) is revised to delete the reference to the Specifications containing the limits specified in the PTLR.
2.
The requirement in ITS 5.6.6, Reactor Coolant System (RCS) PRESSURE AND TEMPERATURE LIMITS REPORT (PTLR), to identify the NRC staff approval document by date is revised to allow the Topical Report(s) to be identified by number and title. A requirement is added to the Reviewers Note to specify the complete citation in the PTLR for each Topical Report, include the report number, title, revision, date, and any supplements.
9/16/2001 Traveler Rev. 2. Copyright (C) 2001, Excel Services Corporation. Use by Excel Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.
TSTF-419 (WOG-154, Rev. 0)
JUSTIFICATION 1.
The definition of PTLR identifies the specifications in which the pressure and temperature limits are addressed. Specification 5.6.6a. requires that the individual specifications that address RCS pressure and temperature limits be referenced. The proposed changes to the definition eliminate duplication between the definition of PTLR and Section 5.6.6.
2.
The revision to ITS 5.6.6 to allow the Topical Reports to be identified by number and title would allow licensees to use current Topical Reports to support limits in the PTLR without having to submit an amendment to facility operating license every time the Topical Report is revised. The PTLR would provide specific information identifying the particular approved Topical Reports used to determine the P/T limits or LTOP System limits. This still provides the assurance that only the approved versions of the referenced Topical Reports will be used for the determination of the P/T limits or LTOP System limits since the complete citation will be provided in the PTLR. This proposed change is consistent with TSTF-363, Revise Topical Report references in ITS 5.6.5, COLR, which was approved by the NRC on April 13, 2000.
The requirement to operate within the limits in the PTLR is specified in and controlled by the technical specifications. Only the figures, values, and parameters associated with the P/T limits and LTOP setpoints are relocated to the PTLR. The methodology for their development must be reviewed and approved by the NRC. The proposed changes do not change the requirements associated with the review and approval of the methodology or the requirement to operate within the limits specified in the PTLR.
DETERMINATION OF NO SIGNIFICANT HAZARDS CONSIDERATION In accordance with the criteria set forth in 10 CFR 50.92, the proposed changes to NUREG-1431 have been evaluated and determined they do not represent a significant hazards consideration. The following is provided in support of this conclusion:
Standard I -
Involves a Significant Increase in the Probability or Consequences of an Accident Previously Evaluated The proposed changes to reference only the Topical Report Number and title do not alter the use of the analytical methods used to determine the P/T limits or LTOP setpoints that have been reviewed and approved by the NRC.
This method of referencing Topical Reports would allow the use of current Topical Reports to support limits in the PTLR without having to submit an amendment to the operating license. Implementation of revisions to Topical Reports would still be reviewed in accordance with 10 CFR 50.59 and where required receive NRC review and approval.
The proposed changes do not adversely affect accident initiators or precursors nor alter the design assumptions, conditions, or configuration of the facility or the manner in which the plant is operated and maintained. The proposed changes do not alter or prevent the ability of structures, systems, and components (SSCs) from performing their intended function to mitigate the consequences of an initiating event within the assumed acceptance limits. The proposed changes do not affect the source term, containment isolation, or radiological release assumptions used in evaluating the radiological consequences of an accident previously evaluated.
Further, the proposed changes do not increase the types or amounts of radioactive effluent that may be released offsite, nor significantly increase individual or cumulative occupational/public radiation exposures. The proposed changes are consistent with safety analysis assumptions and resultant consequences.
Therefore, it is concluded that this change does not increase the probability of occurrence of an accident previously evaluated.
9/16/2001 Traveler Rev. 2. Copyright (C) 2001, Excel Services Corporation. Use by Excel Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.
TSTF-419 (WOG-154, Rev. 0)
Standard II - Create the Possibility of a New or Different Kind of Accident from any Previously Evaluated The proposed changes to reference only the Topical Report Number and title do not alter the use of the analytical methods used to determine the P/T limits or LTOP setpoints that have been reviewed and approved by the NRC.
This method of referencing Topical Reports would allow the use of current Topical Reports to support limits in the PTLR without having to submit an amendment to the operating license. Implementation of revisions to Topical Reports would still be reviewed in accordance with 10 CFR 50.59 and where required receive NRC review and approval.
The changes do not involve a physical alteration of the plant (i.e., no new or different type of equipment will be installed) or a change in the methods governing normal plant operation. In addition, the changes do not impose any new or different requirements or eliminate any existing requirements. The changes do not alter assumptions made in the safety analysis. The proposed changes are consistent with the safety analysis assumptions and current plant operating practice.
Therefore, the proposed change does not create the possibility of a new or different kind of accident from any previously evaluated.
Standard III - Involve a Significant Reduction in the Margin of Safety The proposed changes to reference only the Topical Report Number and title do not alter the use of the analytical methods used to determine the P/T limits or LTOP setpoints that have been reviewed and approved by the NRC.
This method of referencing Topical Reports would allow the use of current Topical Reports to support limits in the PTLR without having to submit an amendment to the operating license. Implementation of revisions to Topical Reports would still be reviewed in accordance with 10 CFR 50.59 and where required receive NRC review and approval. The proposed changes do not alter the manner in which safety limits, limiting safety system settings or limiting conditions for operation are determined. The setpoints at which protective actions are initiated are not altered by the proposed changes. Sufficient equipment remains available to actuate upon demand for the purpose of mitigating an analyzed event.
Therefore, it is concluded that this change does not involve a significant reduction in the margin of safety.
Industry
Contact:
NRC
Contact:
Wideman, Steve (316) 364-4037 stwidem@wcnoc.com Tjader, Bob (301) 415-1187 trt@nrc.gov Revision History OG Revision 0 Revision Status: Active NRC Next Action:
Original Issue Revision
Description:
Revision Proposed by:
Wolf Creek Owners Group Review Information Date Originated by OG:
02-May-01 Owners Group Comments (No Comments)
Date: 02-May-01 Owners Group Resolution:
Approved 9/16/2001 Traveler Rev. 2. Copyright (C) 2001, Excel Services Corporation. Use by Excel Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.
TSTF-419 (WOG-154, Rev. 0)
File to BBS/LAN Date:
TSTF Informed Date:
TSTF Approved Date:
NUREG Rev Incorporated:
Incorporation Into the NUREGs Affected Technical Specifications OG Revision 0 Revision Status: Active NRC Next Action:
TSTF Review Information TSTF Received Date:
02-May-01 Date Distributed for Review:
02-May-01 TSTF Comments:
(No Comments)
Date: 02-May-01 TSTF Resolution:
Approved OG Review Completed:
BWOG CEOG WOG BWROG NRC Review Information NRC Received Date:
15-Sep-01 NRC Comments:
(No Comments)
Final Resolution Date:
Final Resolution:
NRC Action Pending 1.0 Definitions - PTLR 5.6.6 Reactor Coolant System PRESSURE AND TEMPERATURE LIMITS REPORT (PTLR) 9/16/2001 Traveler Rev. 2. Copyright (C) 2001, Excel Services Corporation. Use by Excel Services associates, utility clients, and the U.S. Nuclear Regulatory Commission is granted. All other use without written permission is prohibited.