I -
,==m NWmi Omaha Public PowerDisd 444 South 16th Street Afall Omaha NE 68102-2247 January 28, 2004 LIC-04-0007 U. S. Nuclear Regulatory Commission ATTN.: Document Control Desk Washington, DC 20555
References:
- 1.
Docket No. 50-285
- 2.
Letter from OPPD (S. Gambhir) to NRC (Document Control Desk) dated June 22, 1998 (LIC-98-0082)
SUBJECT:
Fort Calhoun Station Unit No. 1 2003 Refueling Outage Inservice Inspection Results and NIS-1 and NIS-2 Forms Technical Specification Section 5.9.3a and the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, Subsection IWA-6230, require that Omaha Public Power District (OPPD) submit the subject information for Fort Calhoun Station Unit No. 1 (FCS).
Please find enclosed the Inservice Inspection (ISI) results for the FCS 2003 Refueling Outage (RFO), Form NIS-1 "Owner's Report for Inservice Inspections." Also enclosed is the Form NIS-2 "Oner's Report for Repairs or Replacements," for applicable repairs and replacements completed during Fuel Cycle No. 21, including those completed during FCS 2003 RFO.
Included in the NIS-1 Form is a listing of exams performed with less than 100% of Code required volumetric coverage during the 2003 RFO.
In Reference 2, OPPD committed to provide this information on the NIS-1 Form.
Employnent with Equal Opportunity
U. S. Nuclear Regulatory Commission LIC-04-0007 Page 2 No commitments are made to the NRC in this letter. If you have any questions or require additional information, please contact Dr. R. L. Jaworski of my staff at 402-533-6833.
Sincerely, Ench
- 1.
Form NIS-1, Owner's Report for Inservice Inspections
- 2.
Form NIS-2, Owner's Report for Repair/Replacement Activity c:
B. S. Mallett, NRC Regional Administrator, Region IV A. B. Wang, NRC Project Manager J. G. Kramer, NRC Senior Resident Inspector
FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECIIONS As required by the Provisions of the ASME Code Rules
- 1. Owner Omaha Public Power District. 444 S. 16th Street. Omaha. NE 68102 (Name and Address of Owner)
- 2. Plant Fort Calhoun Station, P.O. Box 550, Fort Calhoun, NE 68023 (Name and Address of Plant)
- 3. Plant Unit 1
- 4. Owner Certificate of Authorization (if required),
N/A
- 5. Commercial Service Date 9/26/73
- 6. National Board Number for Unit
- 7. Components Inspected N/A Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.
Province No.
Board No.
RPV CE 66111 20828 RC Pipin. See attached pages for RC Ping az lXm 4
+
4 4
4 1-4 4
4
+
4 4
4 4-4 4
4
.4-
£ I~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
4 4
1 1
4 4-4 4
1 4-4 1
I 4
4 4
I I
Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8M in. x 11 in.,
(2) information in items I through 6 on'this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/881 This form E00029) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.
1 of 15
FORM NIS-1 {sack)
- 8. Examination Dates 9/12/03 to 11/31/03
- 9. Inspection Period Identification
- 10. Inspection Interval Identificatio 3rd n
3rd
- 11. Applicable Edition of Section XI 19 89 Addenda N/A
- 12. Date/Revision of Inspection Plan March 27, 1998 Rev. 3A
- 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.
See Attachment
- 14. Abstract of Results of Examinations and Tests.
See Attachment
- 15. Abstract of Corrective Measures.
See Attachment We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section Xl, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.
Certificate of Authorization No. (if applicable)
N/A Expiration Date N/A Date T4M4.
i g 2004 Signed O
Owner By OPPD CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nebraska and employed by H IR R C T of Hartford, CT have inspected the components described in this Owner's Report during the period 9112103 to 11 /31 /03
, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
________Comm issions e/ 7,4
,AI$
/.5 Inspecto's Signature National Bor.
e'tat:e Proince, and Endorsements Date ______d 2004 2 of 15
OPPD 444 S. 16TH STREET MALL OMAHA, NE 68102 UNIT 1 COMMERCIAL OPS 09/26/1973 FT CALHOUN STATION P.O. BOX 550 FT CALHOUN, NE 68023 SYSTEM PRESSURE TESTS PERFORMED - FORT CALHOUN STATION DURING CYCLE 21 AND 2003 RUFUELING OUTAGE TEST PERFORMED SYSTEM TESTED QC-ST-AFW-3002 FEEDWATER QC-ST-CA-3001 COMPRESSED AIR OP-ST-RC-3007 REACTOR COOLANT QC-ST-CCW-3001 COMPONENT COOLING WATER QC-ST-CH-3001 CVCS QC-ST-CH-3002 CVCS QC-ST-CH-3005 CVCS SE-ST-FO-3001 FUEL OIL SE-ST-FW-3001 FEEDWATER QC-ST-MX-3001 BORATED SYSTEMS QC-ST-IA-3001 INSTRUMENT AIR SE-ST-RW-3001 RAW WATER SE-ST-SA-3002 STARTING AIR SE-ST-SA-3003 STARTING AIR SE-ST-SDC-3003 SHUTDOWN COOLING QC-ST-SI-3004 SAFETY INJECTION QC-ST-SI-3006 SAFETY INJECTION QC-ST-SI-3007 SAFETY INJECTION QC-ST-SI-3008 SAFETY INJECTION QC-ST-SI-3014 SAFETY INJECTION SE-ST-SI-3027 SAFETY INJECTION QC-ST-SL-3001 PRIMARY SAMPLE QC-ST-SL-3002 PRIMARY SAMPLE QC-ST-SL-3003 PRIMARY SAMPLING QC-ST-SL-3004 PRIMARY SAMPLING QC-ST-SL-3005 PRIMARY SAMPLING QC-ST-WDL-3003 WASTE DISPOSAL 3 of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ISI EXAMS WITH <100% ASME CODE COVERAGE Unit 1, Comm. Ops 9126/73 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 COMPONENT ID CAUSE OF LIMITATION
% COVERAGE ISO #
CATEGORY ITEM CONFIGURATION SYSTEM RPV-A-1 I KEYWAYS 98%
A-01 B-A B1.30 UPPER SHELL-TO-FLANGE REACTOR VESSEL RPV-SC-B-1 1 SPECIMEN HOLDER TUBES 90%
A-01 B-A B1.11 MID SHELL-TO-UPPER SHELL REACTOR VESSEL RPV-SC-C-1 1 SPECIMEN HOLDER TUBES 76%
A-01 B-A B1.1 LOWER SHELL-TO-MID SHELL REACTOR VESSEL RPV-SC-16-410 LUGS/FLOW SKIRT 28%
A-01 B-A B1.11 HEAD-TO-LWR SHELL REACTOR VESSEL RPV-SL-B-1 OUTLET NOZZLE BOSS 93%
A-01 B-A B1.12 UPPER LONG SEAM @ 180 DEGREES REACTOR VESSEL RPV-SL-A-3 LUGS/FLOW SKIRT 86%
A-01 B-A B1.12 LOWER LONG SEAM @ 60 DEGREES REACTOR VESSEL RPV-SL-B-3 LUGS/FLOW SKIRT 86%
A-01 B-A B1.12 LOWER LONG SEAM @ 180 DEGREES REACTOR VESSEL RPV-SL-C-3 LUGS/FLOW SKIRT 86%
A-01 B-A B1.12 LOWER LONG SEAM @ 300 DEGREES REACTOR VESSEL RPVLH-411-A FLOW SKIRT 23%
A-02A B-A B1.22 MERIDIONAL @ 30 REACTOR VESSEL RPVLH-411-B FLOW SKIRT 23%
A-02A B-A B1.22 MERIDIONAL @ 90 REACTOR VESSEL RPVLH-411-C FLOW SKIRT 23%
A-02A B-A B1.22 MERIDIONAL @ 150 REACTOR VESSEL RPVLH-41 1-D FLOW SKIRT 23%
A-02A B-A B1.22 MERIDIONAL @210 REACTOR VESSEL RPVLH-411-E FLOW SKIRT 23%
A-02A B-A B1.22 MERIDIONAL @ 270 REACTOR VESSEL RPVLH-411-F FLOW SKIRT 23%
A-02A B-A B1.22 MERIDIONAL @ 330 REACTOR VESSEL RPV-N-1-A INNER RADIUS 82%
A-01 B-D 83.90 NOZZLE-TO-SHELL (OUTLET @ 0 DEGREES)
REACTOR VESSEL RPV-N-2-A INNER RADIUS 92%
A-01 B-D B3.90 NO771 E-TO-SHELL (INLET @ 60 DEGREES)
REACTOR VESSEL RPV-N-2-B INNER RADIUS 92%
A-01 B-D B3.90 NOZZLE-TO-SHELL (INLET @ 120 DEGREES)
REACTOR VESSEL RPV-N-1-B INNER RADIUS 82%
A-01 B-D B3.90 NOZZLE-TO-SHELL (OUTLET @ 180 DEGREES)
REACTOR VESSEL RPV-N-2-C INNER RADIUS 92%
A-01 B-D B3.90 NOZZLE-TO-SHELL (INLET @ 240 DEGREES)
REACTOR VESSEL RPV-N-2-D INNER RADIUS 92%
A-01 B-D B3.90 NOZZLE-TO-SHELL (INLET © 300 DEGREES)
REACTOR VESSEL 4 ofl5
OPPo 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION Xi PSI/ISI EXAMS Unit 1, Comm. Ops 9/26/73 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 Code Category Code Item #
Description ISI Component I.D.
Isometric Inspection
- Results Acceptable B-A B1.1 l lower shell to bottom head RPV-SC-16410 A-01 UT NRI Yes B-A B1.11 upper shell to middle shell RPV-SC-B-1 I A-01 UT NRI Yes B-A B1.11 middle shell to lower head RPV-SCC-11 A-01 UT NRI Yes B-A B1.12 longitudinal weld upper shell (60)
RPV-SL-A-1 A-01 UT NRI Yes B-A B1.12 longitudinal weld middle shell (0)
RPV-SL-A-2 A-01 UT NRI Yes B-A B1.12 longitudinal weld lower shell (60)
RPV-SL-A-3 A-01 UT NRI Yes B-A B1.12 longitudinal weld upper shell (180)
RPV-SL-B-1 A-01 UT NRI Yes B-A B1.12 longitudinal weld upper shell (300)
RPV-SL-C-1 A-01 UT NRI Yes B-A B1.12 longitudinal weld middle shell (240)
RPV-SL-C-2 A-01 UT NRI Yes B-A B 1.12 longitudinal weld lower shell (300)
RPV-SL-C-3 A-01 UT NRI Yes B-A B1.12 longitudinal weld middle shell (120)
RPV-SL-B-2 A-01 UT NRI Yes B-A B1.12 longitudinal weld lower shell (180)
RPV-SL-B-3 A-01 UT NRI Yes B-A B1.21 dollar weld lower head RPVLH-2-411 A-02 UT NRI Yes B-A B1.22 lower head meridional weld at 30 RPVLH-41 1-A A-02 UT NRI Yes B-A B1.22 lower head meridional weld at 90 RPVLH41 1-B A-02 UT NRI Yes B-A Bl.22 lower head meridional weld at 150 RPVLH411-C A-02 UT NRI Yes B-A B1.22 lower head meridional weld at 210 RPVLH-411-D A-02 UT NRI Yes B-A B1.22 lower head meridional weld at 270 RPVLH-41 1-E A-02 UT NRI Yes B-A B1.22 lower head meridional weld at 330 RPVLH-41 1-F A-02 UT NRI Yes B-A B1.30 shell to flange RPV-A-I I A-02A UT NRI Yes B-A B1.22 head meridonal weld at 0 RPVCH-HM-1 A-02A UT NRI Yes B-A B 1.22 head meridonal weld at 60 RPVCH-HM-2 A-02A UT NRI Yes B-A B 1.22 head meridonal weld at 120 RPVCH-HM-3 A-02A UT NRI Yes B-A B1.22 head meridonal weld at 180 RPVCH-HM-4 A-02A UT NRI Yes B-A B 1.22 head meridonal weld at 240 RPVCH-HM-5 A-02A UT NRI Yes B-A B1.22 head meridonal weld at 300 RPVCH-HM-6 A-02A UT NRI Yes B-D B3.100 NIA nozzle inside radius section (hot leg)
RPV-N-1-A-IR A-02 VT enhanced NRI Yes B-D B3.100 NA B nozzle inside radius section (hot leg)
RPV-N-1-B-IR A-01 VT enhanced NRI Yes B-D B3.100 N2A nozzle inside radius section (cold leg)
RPV-N-2-A-IR A-01 VT enhanced NRI Yes B-D B3.100 N2B nozzle inside radius section (cold leg)
RPV-N-2-B-IR A-01 VT enhanced NRI Yes B-D B3.100 N2C nozzle inside radius section (cold leg)
RPV-N-2-C-IR A-01 VT enhanced NRI Yes B-D B3.100 N2C nozzle inside radius section (cold leg)
RPV-N-2-D-IR A-01 VT enhanced NRI Yes B-D B3.90 NIA nozzle (hot leg)
RPV-N-1-A A-01 UT NRI Yes B-D B3.90 NIB nozzle (hot leg)
RPV-N-1-B A-01 UT NRI Yes B-D B3.90 N2A nozzle (cold leg)
RPV-N-2-A A-0
' UT NRI Yes 5 of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION Xl PSI/ISI EXAMS Unit 1, Comm. Ops 9/26173 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 B-D B3.90 N2B nozzle (cold leg)
RPV-N-2-B A-OI UT NRI Yes B-D B3.90 N2C nozzle (cold leg)
RPV-N-2-C A-01 UT NRI Yes B-D B3.90 N2D nozzle (cold leg)
RPV-N-2-D A-O1 UT NRI Yes B-F B5.10 rpv nozzle to safe end (relief request submitted)
MRC-1/01 A-08 UT NRI Yes B-F B5.10 safe end to rpv nozzle (relief request submitted)
MRC-1/18 A-08 UT NRI Yes B-F B5.10 safe end to rpv nozzle (relief request submitted)
MRC-1/30 A-08 UT NRI Yes B-F B5.10 rpv nozzle to safe end (relief request submitted)
MRC-2-01 A-09 UT NRI Yes B-F B5.10 safe end to rpv nozzle (relief request submitted)
MRC-2/18 A-09 UT NRI Yes B-F B5.10 safe end to rpv nozzle (relief request submitted)
MRC-2/30 A-09 UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-08 A-OIA MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-09 A-OIA MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-10 A-OIA MT/UT NRI Yes B-G-I B6.30 rpv closure head stud RPV-G I-S-I A-O1A MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-12 A-01A MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-13 A-O1A MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-14 A-OIA MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-15 A-O1A MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-G1-S-16 A-OIA MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-17 A-O1A MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-18 A-O1A MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-19 A-O1A MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-20 A-OIA MT/UT NRI Yes B-G-I B6.30 rpv closure head stud RPV-GI-S-21 A-O1A MT/UT NRI Yes B-G-I B6.30 rpv closure head stud RPV-GI-S-22 A-O1A MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-23 A-OIA MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-24 A-OIA MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-25 A-O1A MT/UT NRI Yes B-G-1 B6.30 rpv closure head stud RPV-G.-S-26 A-01A MT/UT MU Yes B-G-1 B6.30 rpv closure head stud RPV-GI-S-27 A-O1A MT/UT NRI Yes B-G-I B6.30 rpv closure head stud RPV-GI-S-28 A-O1A MT/UT NRI Yes B-G-I B6.30 rpv closure head stud RPV-GI-S-29 A-OIA MT/UT NRI Yes B-G-I B6.30 rpv closure head stud RPV-GI-S-30 A-OIA MT/UT NRI Yes B-G-I B6.30 rpv closure head stud RPV-GI-S-31 A-OIA MT/UT NRI Yes B-N-I B13.10 vessel interior RPV-NI-I A-O1 VT NRI Yes B-N-2 B 13.50 surveillance capsule RPV-SC-A A-01 B VT NRI Yes B-N-2 B 13.50 surveillance capsule RPV-SC-B A-01B VT NRI Yes B-N-2 B 13.50 surveillance capsule RPV-SC A-01 B VT NRI Yes 6 of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION Xi PS/ISI EXAMS Unit 1, Comm. Ops 9/26/73 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 B-N-2 B13.50 surveillance capsule RPV-SC-D A-01B VT NRI Yes B-N-2 B13.50 surveillance capsule RPV-SC-E A-01B VT NRI Yes B-N-2 B13.50 surveillance capsule RPV-SC-F A-01B VT NRI Yes B-N-2 B 13.60 core support lugs RPV-CS-A A-01B VT NRI Yes B-N-2 B13.60 core support lugs RPV-CS-B A-01B VT NRI Yes B-N-2 B13.60 core support lugs RPV-CS-C A-01B VT NRI Yes B-N-2 B13.60 core support lugs RPV-CS-D A-01B VT NRI Yes B-N-2 B13.60 core support lugs RPV-CS-E A-01B VT NRI Yes B-N-2 B 13.60 core support lugs RPV-CS-F A-01B VT NRI Yes B-N-2 B13.60 core stop lugs RPV-SL-A A-01B VT NRI Yes B-N-2 B13.60 core stop lugs RPV-SL-B A-01B VT NRI Yes B-N-2 B13.60 core stop lugs RPV-SL-C A-01B VT NRI Yes B-N-2 B13.60 core stop lugs RPV-SL-D A-01B VT NRI Yes B-N-2 B13.60 core stop lugs RPV-SL-E A-01B VT NRI Yes B-N-2 B13.60 core stop lugs RPV-SL-F A-01B VT NRI Yes B-N-2 B13.60 core stop lugs RPV-SL-G A-01B VT NRI Yes B-N-2 B13.60 core stop lugs RPV-SL-H A-01B VT NRI Yes B-N-2 B 13.60 core stoP lugs RPV-SL-J A-01B VT NRI Yes B-N-3 B 13.70 core support structure RPV-N3-CSS-1 A-01 VT NRI Yes F-A F1.20 pipe support 4-CH-11114-PR B-74 VT NRI Yes F-A F1.20 pipe support 4-CH-11/16-PR B-74 VT NRI Yes F-A Fl.20 pipe support 2-CH-24/09-PR B-77 VT NRI Yes F-A Fl.20 pipe support 2-CH-26/19-PR B-79 VT NRI Yes B-J B9.11 preservice S-208 12-SI-22/17A A-24 PTRT NRI Yes B-J B9.1 1 preservice Sl-208 12-SI-22118 A-24 PT/RT NRI Yes B-J B9.11 preservice SI-208 12-SI-22/19 A-24 PT/RT NRI Yes B-J B9.11 preservice SI-208 12-SI-22/120 A-24 PT/RT NRI Yes B-J B9.11 preservice SI-208 12-SI-22/20A A-24 PT/RT NRI Yes B-J B9.l1 preservice SI-197 6-SI-24/04 A-29 PT/RT NRI Yes B-J B9.11 reservice SI-1 97 6-Sl-24/05 A-29 PT/RT NRI Yes B-J B9.1 1 preservice SI-194 6-SI-22103 A-28 PT/UT NRI Yes B-J B9.11 preservice Sl-194 6-Sl-22/04 A-28 PT/UT NRI Yes B-J-2 B7.30 preservice SG-A inlet manway SG-1-1 A-O5 VT NRI Yes B-G-2 B7.30 preservice SG-A outlet manway SG-1-2 A-05 VT NRI Yes B-G-2 B7.30 preservice SG-B inlet manway SG-2-1 A-06 VT NRI Yes B-G-2 B7.30 reservice SG-B outlet manwa SG-2-2 A-06 VT NRI Yes F-A F1.10 preservice support SIH-142 12-Sl-22/17-PR A-24 VT NRI Yes 7 of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION Xi PSI/ISI EXAMS Unit 1, Comm. Ops 9/26/73 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 F-A F1.10 preservice support SIH-182 6-SI-24/07-PR-2 A-29 VT NRI Yes F-A F1.20 preservice support SIH-236/HCV-331-S 6-LPH-2022/08-PR B-31 VT NRI Yes F-A F1.20 preservice support SIH-205 6-SI-2022/01A-PR B-31 VT NRI Yes F-A F1.20 preservice support SIH-212 6-SI-2024/11-PR B-32 VT NRI Yes F-A F1.20 preservice support SIS-192/HCV-333-S 6-SI-2024/PS-197 B-32 VT NRI Yes F-A Fl.20 preservice support SIS-161 6-LPH-2014/09-PR-2 B-34 VT NRI Yes N/A N/A preservice snubber MSS-8B 28-MS-2001/06-PR-2 B-03 VT NRI Yes N/A N/A preservice snubber SIS-168A 6-SI-2024/02-PR B-32 VT NRI Yes N/A N/A preservice snubber ACS-299A 10-AC-2003/08-PR-1 B-56 VT NRI Yes Note: *No Rejectable Indications 8 of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION XI IWE EXAMS Unit 1, Comm. Ops 9126173 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 Code Case GENERAL INFORMATION NOTES and COMMENTS or Relief Results Acceptable EXAM AREA or ISO CAT ITEM REQD COMPONENT ID NO.
NO.
NO.
EXAM LIN-001 FCS-001/1 E-A E1.11 VT-G 0-90, 1042'- 1099' IWE-006 NRI Yes LIN-001 FCS-001/2 E-A E1.11 VT-G 0-45, 991'- 1042' IWE-006 NRI Yes LIN-001 FCS-001/3 E-A E1.11 VT-G 45-90,991' - 1042' IWE-006 NRI Yes LIN-001 FCS-001/4 E-A E1.11 VT-G 90-180, 1042'- 1099' IWE-006 NRI Yes LIN-001 FCS-001/5 E-A E1.11 VT-G 90-180, 991'- 1042' IWE-006 NRI Yes LIN-001 FCS-001/6 E-A E1.1 I VT-G 180-270,1042'- 1099' IWE-006 NRI Yes LIN-001 FCS-001/7 E-A E1.11 VT-G 180-270, 991'- 1042' IWE-006 NRI Yes LIN-001 FCS-001/8 E-A E1.11 VT-G 270-360,1042'- 1099' IWE-006 NRI Yes LIN-001 FCS-001/9 E-A E1.11 VT-G 270-360, 991' - 1042' IWE-006 NRI Yes LIN-002 FCS-001/10 E-A E1.11 VT-G 1099' to Top Dome IWE-006 NRI Yes IWE-00i AIR-001 FCS-001/2 E-A E1.11 VT-G Personnel Air Lock IWE-006 NRI Yes IWE-001 HAT-001 FCS-001/5 E-A E1.11 VT-G Equipment Hatch IWE-006 NRI Yes HAT-001 FCS-001/5 E-G E8.10 VT-3 Equipment Hatch Bolting IWE-002 NRI Yes MB-001 None E-D E5.30 VT-G Moisture Barrier NRI Yes IWE-001 IWE-002 M-100 FCS-001/7 E-A E1.11 VT-3 Spent Fuel Transfer Tube IWE-006 Inaccessible N/A M-100 FCS-002 E-G E8.10 VT-3 Spent Fuel Transfer Tube Bolting IWE-002 NRI Yes M-1 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-2 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-3 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-4 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-5 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-6 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-7 FCS-001/2 E-A E`1.11 VT-G IWE-006 NRI Yes M-8 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-9 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-10 FCS-001/2 E-A E1.1 1 VT-G IWE-006 NRI Yes M-11 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-12 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-13 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-14 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes 9 of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION Xl IWE EXAMS Unit 1, Comm. Ops 9/26/73 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 M-15 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-16 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-17 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-18 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-19 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-20 FCS-001/2 E-A E1.1 I VT-G IWE-006 NRI Yes M-21 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-22 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-23 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-24 FCS-001/2 E-A E1.1 1 VT-G IWE-006 NRI Yes M-25 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-26 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-27 FCS-001/9 E-A E1.11 VT-G
_ IWE-006 NRI Yes M-28 FCS-401/9 E-A E1.11 VT-G IWE-006 NRI Yes M-29 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-30 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-31 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-32 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-33 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-34 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-35 FCS-001/2 E-A E1.1I VT-G IWE-006 NRI Yes M-36 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-37 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-38 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-39 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-40 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-41 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-42 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-43 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-44 FCS-001/2 E-A E1.11 Vr-G IWE-006 NRI Yes M-45 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-46 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-47 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-48 FCS-401/9 E-A E1.1I VT-G IWE-006 NRI Yes M-49 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-50 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-51 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-52 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-53 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes 1O,of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION XI IWE EXAMS Unit 1, Comm. Ops 9/26/73 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 M-54 FCS-01/2 E-A E1.11 VT-G IWE-006 NRI Yes M-55 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-56 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-57 FCS-001/2 E-A E1.1I VT-G IWE-006 NRI Yes M-58 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-59 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-60 FCS-001/9 E-A E1.11
_ VT-G IWE-006 NRI Yes M-61 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-62 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-63 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-64 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-65 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-66 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-67 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-68 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-69 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-70 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-71 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-72 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-73 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-74 FCS-00119 E-A E1.11 VT-G IWE-006 NRI Yes M-75 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-76 FCS-001/9 E-A E1.1I VT-G IWE-006 NRI Yes M-77 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-78 FCS-001/2 E-A E1.1 VT-G IWE-006 NRI Yes M-79 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-80 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-81 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-82 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-83 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-84 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-85 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-86 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-87 FCS-001/2 E-A E1.11 VT-G IWE-006 NRI Yes M-88 FCS-001/9 E-A E1.11 VT-G IWE-006 NRI Yes M-89 FCS-001/2 E-A E1.11 Vr-G IWE-006 NRI Yes M-90 FCS-001/3 E-A E1.11 VT-G IWE-006 NRI Yes M-91 FCS-001/3 E-A E1.1 VT-G IWE-006 NRI Yes M-92 FCS-001/3 E-A EI.11 VT-G IWE-006 NRI Yes 11 of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION Xl IWE EXAMS Unit 1, Comm. Ops 9/26/73 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 M-93 FCS-001/3 E-A E1.1 IVT-G IWE-006 NRI Yes M-94 FCS-001/3 E-A E1.11 VT-G IWE-006 NRI Yes M-95 FCS-001/5 E-A E1.1I VT-G IWE-006 NRI Yes M-96 FCS-001/5 E-A E1.11 VT-G IWE-006 NRI Yes M-97 FCS-001/5 E-A E1.1 VT-G IWE-006 NRI Yes M-98 FCS-001/5 E-A E1.11 VT-G IWE-006 NRI Yes M-99 FCS-001/5 E-A E1.11 VT-G IWE-006 NRI Yes IWE-001 A-1 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 A-2 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 A-4 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 A-5 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 A-6 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 A-7 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 A-8 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 A-9 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 A-10 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 A-1I FCS-001/3 E-A E1.1I VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 B-I FCS-001/5 E-A E1.1I VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 B-2 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 B-5 FCS-001/5 E-A E1.1I VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 B-6 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 B-7 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 B-7 IFCS-01/5 E-A El1.1 1 VT-C IWE-001 applies to Cat E-D IWE-006 INRI Yes 12 of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION Xl IWE EXAMS Unit 1, Comm. Ops 9126/73 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 IWE-001 B-8 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes
[WE-001 B-9 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 B-10 FCS-001/3 E-A E1.1 I VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 B-1I FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 C-1 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 C-2 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 C4 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 C-6 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 C-6 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 C-7 FCS-00115 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 C-B FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 C-9 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 C-11 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 C-1l FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 D-I FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 D_
FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 D-5 FCS-001/5 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yesl IWE-001 D-6 IFCS-001/5 IE-A iE1.11 VT-G IWE-001 applies to Cat E-D IIWE-006 INRI Yes 13 of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION Xl IWE EXAMS Unit 1, Comm. Ops 9/26/73 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 IWE-001 D-7 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 D-8 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 0-9 FCS-001/3 E-A EI.1 I VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes D-10 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 D-11 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 E-1 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 E-2 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 E-4 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 E-5 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 E-7 FCS-001/5 E-A E1.1 I VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 E-8 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 E-9 FCS-001/3 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 E-10 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 E-10 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 F-1 FCS-001/5 E-A E1.1I VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 F-2 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 F-2 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 F-5 FCS-001/5 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes 14 of 15
OPPD 444 South 16th Street Mall Omaha, NE 68102 2003 REFUELING OUTAGE ASME SECTION XI IWE EXAMS Unit 1, Comm. Ops 9/26/73 Fort Calhoun Station Post Office Box 550 Ft. Calhoun, NE 68023 IWE-001 F-6 FCS-001/5 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 F-7 FCS-001/5 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 F-8 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 F-9 FCS-001/3 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 F-10 FCS-001/3 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 F-1I FCS-001/3 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-401 G-1 FCS-001/4 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 G-2 FCS-001/4 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 G-3 FCS-001/4 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 G-4 FCS-001/4 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-01 H-I FCS-001/4 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 H-2 FCS-001/4 E-A E1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE-001 H-3 FCS-001/4 E-A E1.1 1 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes IWE H-4 FCS-001/4 IE-A El1.11 VT-G IWE-001 applies to Cat E-D IWE-006 NRI Yes Note: No Rejectable Indications per ASME Section XI table IWE-341 0-l 15 of 15
FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,.Section Xi I. Owner Omaha Public Power District Name 444 S. 16th Street, Mall Omaha NE Address
- 2. Plant Fort Calhoun Station Name P.O. Box 550, Fort Calhoun NE 68023 Address Date
-. J ri. 7, 2004 Sheet 1
.. of 8
Unit NO.
1 Omah Pblie Pnupr T) er; ivt-Repair/Replacnent Organization P.O. No. Job No.. etc.
- 3. Work Performed by rnl oa hihi 4 t Ppr I iitrictType Code Symbol Stamp W A Authorization No.
CP Am~rse.
Expiration Date NIA Address
- 4. Identification of System See tt ch-d Sheets See attached Sheets, S. (a) Applicable Construction Code
,19
- Edition, Addenda, Code Case (b) Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 19 89
- 6. Identification of Components:
ASME National Corrected, -
code Name o Name of Manufacturer Board Year Removed, or Stamped Component Manufacturer Serial No..
No.
Other Identification Built Installed (Yes or No)
See attzched sheet
- 7. Description of Work See attached sheets S. Tests Conducted:
Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Exempt 0 Other 0 Pressure psi Test Temp.
- F See attached sheets NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in x I1 in.,
(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.
(12195)
This form may be obtained from the Order Dept., ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007-2300.
REPRINT 7196 11111111111 011111111111 E00030 Sheet I of 8
FORM NIS-2 (Back)
- 9. Remarks N /
Applicable Manufacturer's Data Reports to be attached iii I
I CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that-this conforms to the requirements of the ASME Code, Section Xi.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Ciod
.#9As'1CJC - SwCAMt0 AV, '
Expiration Date N/A n%.+. 7sA^00'-'P It 7C00V Owner or Owners Designree, Title f
9 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holdina avalid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ebraska and employed by HSB CT of qr'f nA, CT havp inspected the components described in this Owner's Report during the period e'@'1'O9 to O///510'(
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.
Commi a
4i-nq Date I6(pectors Signatura aa
/
National Boar. Sate,'Province, and Endorsements Sheet 2 of 8
OPPO 444 S. 16TH STREET MALL OMAHA, NE 68102 UNIT 1 COMMERCIAL OPS 09/2611973 FT CALHOUN STATION P.O. BOX 550 FT CALHOUN, NE 68023 ASME COMPONENTS REPAIRED/REPLACED - FORT CALHOUN STATION DURING CYCLE 21 AND 2003 REFUELING OUTAGE NATL -
I
~~~~~~~~~~~ASME WORK BOARD APPUCABLE YEAR CODE REPAIR/
DOCUMENT COMPONENT CL SER. NO MANUF.
NO.
SYS.
WORK PERFORMED CONSTRUCTION CODE BUILT STAMP-YIN REPLACEMENT TEST CONDUCTED PT. VT.
WO 59382-01...
~~~~~~~~~~~~~~~~~~~
(85PSV/65F)
EC 14947 RC-3A 2
NtA N/A NtA CCW REPLACED PIPING USAS 831.7 68 DRAFT 1970 N
REPLACEMENT CC-N-416-1 WO166611-0 CH-187 2
N/A FLOWSERVE N/A CVCS REPLACED BONNET ASME III 83S83 1993 N
REPLACEMENT VT-2 (2165PSU1 16F)
WO 76794-01 AMATEK
.T-
.25PV4F EC 25378' HCV-331 2
NIA CALMAC N/A ILP-SI REPLACED VALVE & PIPING USAS B31.7 68 DRAFT 1971 N
REPLACEMENT CC N416-1 WO 87967401 REPLACED VALVE EC 31954 PCV102 2 1
BL-06978 DRESSER NIA RC FASTENERS USAS 831.7 68 DRAFT 1970 Y
REPLACEMENT VT-2 (2150PSU440F)
WO 104601-01 EC 25376 l SIH-236 2
N/A NIA NIA LP-SI REPLACED SUPPORT AISC STEEL MANUAL 5TH 1971 N
REPLACEMENT VT. VT-3 W091589-01 PT.
.T.
UT. VTP WO 91590-01 56979 VT-2 (278PU86F)
- SI-194 & SI-197 1
56801 MISSION NIA LP-SI REPLACED VALVE & PIPING USAS 831.7 68 DRAFT 1971 N
REPLACEMENT CC N-416-1 Was 76794-04&05 SIH-182, SIH-205.
Was 91590-02&03 SIS-161. StS-168A 1&2 NA NA NA LP-SI MODIFIED SUPPORTS AtSC STEEL MANUAL 5TH 1973 N
REPAIR PT. VT. VT-3 EC 11302 BYRON REPLACED PUMP &
CWO 99-004 AC-10A 3
N/A JACKSON NIA AC-RW FASTENERS CONTRACT 763 1973 N
REPLACEMENT.
VT-2 32PSt/51F)
WO 76794-01 EC 29838 HCV-331 2
D-232T.1 FLOWSERVE N/A LP-SI INSTALLED SMART STEM ASME It 92 2001 N
REPLACEMENT NUA WO 131962-01 SI-188 I
TC73502 DRESSER N/A SI-SDC REPLACED VALVE USAS B31.7 68 DRAFT 1973 N
REPLACEMENT VT-2 (5PSV/80F)
VARIOUS NG, RC.
WO 110536-01 SI, WD PIPE NG. RC.
EC 28526 SUPPORTS 2
N/A N/A N/A Si. WD INSTALLED PIPE SUPPORTS USAS 831.7 68 DRAFT 2003 N
REPLACEMENT VT WO 114451-04 BYRON REPLACED PUMP COVER &
EC 32861 RC-38 1
671-N-0031 JACKSON N/A RC CCW FLANGE FASTENERS ASME III 65S66 1973 N
REPLACEMENT VT-2 (2150PSV440F)
N/A CRANE N/A CVCS REPLACED FASTENERS USAS B31.7 68 DRAFT 1973 N
REPLACEMENT VT-2 (NOP/NOT)
VT. PT. RT, WO 124106-01 51293-X-
.VT-2 (210PS 30F)
EC 30593 SI-208 1
6397 MISSION NIA SI-SDC REPLACED VALVE & PIPING USAS B31.7 68 DRAFT 1971 N
REPLACEMENT CCN-416-1 WO 124106-04/05 EC 30593 SIS-119 & SIH-142 1
NIA N/A N/A HP-SI MODIFIED SUPPORTS AISC STEEL MANUAL 5TH 1971 N
REPLACEMENT VT, VT-3 PT VT WO 10584841 VT-2 (1410PNOT)
EC 29238 HCV-315 2
NIA VELAN NIA HP-Si REPLACED VALVE & PIPING USAS 831.768 DRAFT 1971 N
REPLACEMENT CC-N4 16-1 VT. PT. RT.
WO 124104-01 AMATEK VT-2 (25P F)
EC 30769 HCV-333 2
NUA CALMAC.
NIA LP-SI REPLACED VALVE & PIPING USAS B31.7 68 DRAFT 1971 N
REPLACEMENT CC-N-416-1 WO 124104-04/06.
EC 30769 SIS-192 & SIH-212 2
NA N/A NIA Si MODIFIED SUPPORTS AISC STEEL MANUAL 5TH 1971 N
REPLACEMENT VT. VT-3 ADDED ONE PSA-1/2 N/A.- ADDED ONE NEW MM-ST-MSS-0001 PACIFIC SNUBBER TO THE EXISITNG SNUBBER TO EXISTING EC 11038 PSA SNUBBER ALL 20521 SCIENTIFIC N/A RC POPULATION USAS B31.7 68 DRAFT 1980 N
REPLACEMENT POPULATION WO 145935-01 LO-33-1 3
N/A N/A NIA 10 REPLACED PIPE CONTRACT 763 1973 N
REPLACEMENT VT-2 (65PSU1/10F) 1/1512004 Sheet 3 of 8
OPPD 444 S. 16TH STREET MALL OMAHA, NE 68102 UNIT 1 COMMERCIAL OPS 09/26/1973 FT CALHOUN STATION P.O. BOX 550 FT CALHOUN, NE 68023 ASME COMPONENTS REPAIREDIREPLACED - FORT CALHOUN STATION DURING CYCLE 21 AND 2003 REFUELING OUTAGE J
NATL ASME WORK
.OMPO~*
CLI.NO BOARD WORK-APPUCABLE YEAR CODE REPAIR/
l DOCUMENT COMPONENT CL SER. NO MANUF.
NO.
SYS.
WORK PERFORMED CONSTRUCTION CODE BUILT STAMPY/N REPLACEMENT TEST CONDUCTED REPLACED PLUG & SEAT WO 119986-01 HCV-1108B 2
4662083 FISHER NUA FW-AFW RING USAS B31.7 68 DRAFT 1973 N
REPLACEMENT VT-2 (890PSU82F)
MACHINED GASKET FACE OF PT, VT.
WO 155712-01 HCV.1108A 2
462081 FISHER N/A FW-AFW CYLINDER USAS B31.7 68 DRAFT 1973 N
REPAIR VT-2 (885PS182F)
VT, VT-2 (87PSV73F) CC WO 155762-01 VA-1A 2
N/A N/A N/A VA-CON REPAIRED TUB3E LEAK CONTRACT 763 1972 N
REPAIR N-416-1 WO 124970-01 RC-2A 1
66505 CE 20880 RC INSTALLED TUBE PLUGS ASME III 65W68 1970 Y
REPAIR N/A CC N-474-1 WO 124955-01 RC-2B 1
66506 CE 20880 RC INSTALLED TUBE PLUGS ASME III 65W66 1970 Y
REPAIR N/A CC N-474-1 VT. PT. VT.2 (81PSU158F)
WO 120216-01 RC-38 2
N/A N/A N/A AC-CCW REPLACED WELDS USAS B31.7 68 DRAFT 1973 N
REPLACEMENT CCN-416-1 WO 131115-01 WO 131487-01 EC 30568 FW.163 & FW-164 2
N/A MISSION N/A FW-AFW REPLACED VALVES USAS B31.7 68 DRAFT 1972 N
REPLACEMENT VT-2 (885 PSV82F)
WO 97507-01 HCV-28828 3
12112790 FISHER N/A AC-RW REPLACED FASTENERS USAS 831.7 68 DRAFT 1973 N
REPLACEMENT VT-2 (15PSU48F)
INGERSOL.
WO 117039-01 SI-3C 2
066942 RAND N/A SI-CS REPLACED FASTENERS USAS 831.7 68 DRAFT 1973 N
REPLACEMENT VT-2 (12PSV89F)
WO 2127401 HCV-2883A 3
N/A FISHER N/A AC-RW REPLACED FASTENERS USAS 631.7 68 DRAFT 1973 N
REPLACEMENT VT-2 (28PSU/54F)
WO 129471-01 AC-ID 3
N/A WHITLOCK N/A AC-RW REPLACED FASTENERS USAS B31,7 68 DRAFT 1971 N
REPLACEMENT VT-2 (28PSUSOF)
BYRON WO 146280-01 AC-lOB 3
N/A JACKSON N/A AC-RW REPLACED FASTENERS CONTRACT 763 1973 N
REPLACEMENT N/A WO 13229941 WO 15514901 SCHUTTE-REPLACED FASTENERS &
R EPLACEMENT &
EC 29600 HCV-10410 2
N/A KOERTING N/A MS MACHINED BONNET USAS B31.7 68 DRAFT 1973 N
WO 132296-01 WO 125469-01 WO 155148-01 SCHUTTE-REPLACED FASTENERS &
REPLACEMENT &
NIA KOERTING NZA MS MACHINED BONNET USAS B31,7 68 DRAFT 1973 N
WO 124320.01 RC-2A 1
66505 CE 20879 RC REPLACED FASTENERS ASME III 65W66 1973 V
REPLACEMENT VT-2 (2150PSU440F)
RC-2B 1
66506 CE 20880 RC REPLACED FASTENERS ASME III 65W66 1973 Y
REPLACEMENT VT-2 (2150PSU440F)
ALLIS WO 89607-01 VA-283 3
67457-5 CHALMERS N/A VA-CON REPLACED FASTENERS USAS B31.7 68 DRAFT 1973 N
REPLACEMENT VT-2 (12PS/75F)
WO 133052-01 FW.162 2
54628 MISSION N/A FW REPLACED FASTENERS USAS B31.7 68 DRAFT 1973 N
REPLACEMENT VT-2 (90OPSU/430F)
WO 12613901 FH-5 2
N/A CE N/A CONT.
REPLACED FASTENERS ASME 11168 1970 N
REPLACEMENT VT-3. LLRT BERGEN WO 136325-03 MSS-88 2
N/A PATERSON N/A MS REPLACED FASTENERS USAS B31.7 68 DRAFT 1973 N
REPLACEMENT VT-3.
BERGEN WO 156287-01 ACS-299A 2
N/A PATERSON N/A AC-CCW REPLACED FASTENERS USAS B31,7 68 DRAFT 1973 N
REPLACEMENT VT-3 RC-CCW WO 149006-01 FLANGE 2
N/A N/A N/A AC-CCW REPLACED FASTENERS USAS 631.7 68 DRAFT 1973 N
REPLACEMENT VT-2 (100PSU60F)
BERGEN WO 15854901 SIH-285 3
N/A PATERSON N/A SI REPLACED FASTENERS USAS B31.7 68 DRAFT 1973 N
REPLACEMENT VT.
Sheet 4 of 8 1/15/2004
. 444 S. 16TH STREET MALL OMAHA, NE 68102 UNIT 1 COMMERCIAL OPS 09126/1973 SNUBBERS REPLACED - FORT CALHOUN STATION CYCLE 21 AND 2003 REFUELING OUTAGE FT CALHOUN STATION P.O. BOX 550 FT CALHOUN, NE 68023 SNUBBER - LOCATION I MFG [SN REMOVEDI SIN INSTALLED DATE INSTALLEDILOCATION OF REMOVEDIFUNCTIONAL TESTI EXAMINATIONS SNUBBERS REQUIRED TO BE FUNCTION TESTED l
._____._l_=
ACS-117 BP FC-003-338 FC-003-113 09/16103 SPARE Y -37 VT-3 FWS-100 BP FC-003-088 FC-003-092 07/30103 FWS-8D Y -37 VT-3 FWS-101 BP FC-003-092 FC-003-017 07/28/03 FWS-100 Y -37 VT-3 FWS-29A BP FC-003-354 FC-003-091.
07/30/03 FWS-8F Y-37 VT-3 FWS-38 BP FC-003-050 FC-003-076 09/16/03 SPARE Y -37 VT-3 FWS-79 BP FC-003-091 FC-003-095 07/28103 FWS-29A Y-37 VT-3 FWS-7D-SOUTH BP FC-003-103 FC-003-011 08/05/03 SPARE Y -37 VT-3 FWS-8D BP FC-003-011 FC-003-088 08101/03 FWS-7D-SOUTH Y -37 VT-3 FWS-8F BP FC-003-039 FC-003-354 08/01/03 SPARE Y -37 VT-3 HCV-327-S PM PD26971-1251 PD26971-1251 10/01/03 HCV-327-S Y -37 VT-3 MSS-1 BP FC-010-031 FC-010-052 09/17/03 MSS-8TOP Y -37 VT-3 MSS-11-TOP BP FC-010-090 FC-010-093 07/2203 MSS-14C-BOTTOM Y -37 VT-3 MSS-14C-BOTTOM BP FC-010-091 FC-010-090 07/29103 RWS-128-EAST Y -37 VT-3 MSS-16-TOP BP FC-020-003 FC-020-026 08/01/03 MSS-12-TOP Y -37 VT-3 MSS-2 BP FC-020-002 FC-020-010 09/17/03 SPARE Y -37 VT-3 MSS-8-TOP BP FC-010-065 FC-010-031 09/22/03 SIS-5 Y -37 VT-3 RCP-A1 G
FC-050-001 FC-050-008 09/27/03 SPARE Y -37 VT-3 RCP-B4 G
FC-021-003 FC-021-009 10/07/03 RCP-B3 Y-37 VT-3 RCS-14C BP FC-003-253 FC-003-257 09/19/03 SPARE Y -37 VT-3 RCS-19A-LEFT BP FC-003-104 FC-003-082 09/18/03 SPARE Y-37 VT-3 RCS-19A-RIGHT BP FC-003-054 FC-003-199 09/18/03 SPARE Y-37 VT-3 RCS-31 BP FC-003-067 FC403-159 09/17/03 SPARE Y-37 VT-3 RCS-4 BP FC-003-192 FC-003-352 09/18/03 SPARE Y -37 VT-3 RCS-5 BP FC-003-053
-FC-003-236 09/18/03 ACS-299A Y -37 VT-3 RCS-67 PSA SN 5908 SN 5908 10/0203 RCS-67 Y - 10%
VT-3 RCS-68 PSA SN 5901 SN 5901 10/02103 RCS-68 Y-10%
VT-3 RCS-69 PSA SN 5905.
SN 5905 10/02103 RCS-69 10% EXPANDED VT.3 RCS-70 PSA SN 15221 SN 15221 10/02/03 RCS-70 10% EXPANDED VT-3 RWS-128-EAST BP FC-010-103 FC-010-091 07/30/03 SPARE Y -37 VT-3 SG-A3 G
FC-133-002 FC-133-005 10/01/03 SPARE Y-37 VT-3 SIS-118A
.BP FC-010-044 FC-010-006 09/16/03 SIS-164 Y-37 VT-3 SIS-140
-PSA SN 20487 SN 20487 10/02103 SIS-140 RETEST VT-3 ASME SECTION X - 1989 Sheet 5 of 8 1/15/2004
OPPD 444 S. 16TH STREET MALL OMAHA, NE 68102 UNIT I COMMERCIAL OPS 09/26/1973 SNUBBERS REPLACED - FORT CALHOUN STATION CYCLE 21 AND 2003 REFUELING OUTAGE FT CALHOUN STATION P.O. BOX 550 FT CALHOUN, NE 68023 SNUBBER - LOCATION I MFG ISIN REMOVED ISIN INSTALLED IDATE INSTALLEDI LOCATION OF REMOVEDIFUNCTIONAL TESTl EXAMINATIONS SIS-165A-BOTTOM BP FC-003-107 FC-003-310 09114/03 SPARE Y - 37 VT-3 SIS-35-BOTTOM BP FC-010-052 FC-010-004 08/12/03 MSS-1 Y -37 VT-3 SIS-35-TOP BP FC-010-004 FC-010-046 08111/03 SIS-35-BOTTOM Y-37 VT-3 SIS-4 BP FC-003-263 FC-003-224 08105/03 SIS-56A Y - 37 VT-3 SIS-56 BP FC-003-327 FC-003-166 07/09/03 SPARE Y -37 VT-3 SIS-56A BP FC-003-035 FC-003-263 08105/03 SIS-82 Y -37 VT-3 SIS-77 BP FC-003-178 FC-003-116 08/11/03 WDS-107 Y - 37 VT-3 SIS-82 BP FC-003-116 FC-003-035 08/06103 SIS-77 Y - 37 VT-3" WDS-107 BP FC-003-234 FC-003-178 08/12/03 SIS-81B Y - 37 VT-3 WDS-289 BP FC-003-280 FC-003-187 09/16/03 SPARE Y - 37 VT-3 SNUBBERS CHANGED OUT OR REBUILT DUE TO MAINTENANCE/SEAL LIFE.
ACS-18 BP FC-003-337 FC-003-288 07/09/03 SPARE Y
VT-3 ACS-113A BP FC-010-089 FC-010-068 09/27/03 SIS-68 Y
VT-3 ACS-116 BP FC-003-350 FC-003-217 09/16/03 SPARE Y
VT-3 ACS-117 BP FC-003-338 FC-003-113 09/16/03 SPARE Y
VT-3 ACS-299A BP FC-003-080 FC-003-053 10/10/03 SPARE Y
VT-3 FWS-1C BP FC-010-071 FC-010-013 09t22103 SIS-27 VT-3 FWS-11-BOTTOM BP FC-020-025 FC-020-021 08/25/03 MSS-12-BOTTOM Y
VT-3 FWS-11-TOP BP FC-020-026 FC-020-017 07/23/03 MSS-16-TOP V
VT-3 FWS-38 BP FC-003-050 FC-003-076 09/16103 SPARE Y
VT-3 FWS-39 BP FC-003-100 FC-003-231 09/20/03 SPARE Y
VT-3 FWS-79 BP FC-003-091 FC-003-095 07/28/03 FWS-29A Y
VT-3 FWS-101 BP FC-003-092 FC-003-017 07/28/03 FWS-100 V
VT-3 MSS-1 BP FC-010-031 FC-010-052 09/17/03 MSS-8-TOP y
VT-3 MSS-2 BP FC-020-002 F-020-010 09/17/03 SPARE VT-3 MSS-8D BP FC-003-241 FC-003-078 09/26t03 SPARE Y
VT-3 MSS-9C-TOP BP FC-010-020 FC-010-097 07/23/03 SPARE Y
VT-3 MSS-11-BOTTOM BP FC-010-092 FC-010-014 09/15t03 SPARE Y
VT-3 MSS-11-TOP BP FC-010-090 FC-010-093 07/22/03 MSS-14C-BOTTOM Y
VT-3 MSS-12-BOTOM BP FC-020-020 FC-020-025 09/15/03 SPARE Y
VT-3 MSS-12-TOP BP FC-020-021 FC-020-003 08/13/03 FWS-1-BOTTOM Y
VT-3 MSS-12A-NORTH G
FC-32272 FC-32272 10/02/03 MSS-12A-NORTH V
VT-3 MSS-12A-SOUTH G
FC-32271 FC-32271 10/02/03 MSS-12A-SOUTH Y
VT-3 ASME SECTION X - 1989 Sheet 6 of 8 1/15/2004
OPPD 444 S. 16TH STREET MALL OMAHA, NE 68102 UNIT 1 COMMERCIAL OPS 09/26/1973 SNUBBERS REPLACED - FORT CALHOUN STATION CYCLE 21 AND 2003 REFUELING OUTAGE*
FT CALHOUN STATION P.O. BOX 550 FT CALHOUN, NE 68023 SNUBBER - LOCATION I MFG IS/N REMOVEDIS/N INSTALLEDIDATE INSTALLEDILOCATION OF REMOVEDlFUNCTIONAL TESTl EXAMINATIONS MSS-16A-NORTH G
FC-32273 FC-32273 10/02103 MSS-16A-NORTH Y
VT-3 MSS-16A-SOUTH G
FC-32274 FC-32274 10/02103 MSS-16A.SOUTH Y
VT-3 MSS-16-TOP BP FC-020-003 FC-020-026 08/01/03 MSS-12-TOP.
Y VT-3 RCP-A1 G
FC-050-001 FC-050-008 09/27/03 SPARE Y
VT-3 RCP-B3 G
FC-021-005 FC-021-003 10/08/03 SPARE Y
VT-3 RCS-14C BP FC-003-253 FC-003-257 09/19/03 SPARE Y
VT-3 RCS-19A-LEFT BP FC-003-104 FC-003-082 09/18103 SPARE Y
VT-3 RCS-31 BP FC-003-067 FC-003-159 09/17103 SPARE Y
VT-3 RCS-64-UPPER BP FC-003-249 FC-003-142 09/16103 SPARE Y
VT-3 SG-A3 G
FC-133-002 FC-133-005 10/01/03 SPARE Y
VT-3 SG-A4 G
FC-133-001 FC-133-006 10/01/03 SPARE Y
VT-3 SIS-3 BP FC-003-326 FC-003-333 07/10103 SPARE.
Y VT-3 SIS4 OBP FC-003-263 FC-003-224 08/05/03 SIS-56A Y
VT-3 SIS-5 BP FC-010-056 FC-010-065 10/04/03 SIS-95 Y
VT-3 SIS-10 BP FC-003-187 FC-003-283 07/21/03 WDS-289 Y
VT-3 SIS-16A BP FC-003-177 FC-003-343 07/10/03 SPARE Y
VT-3 SIS 17 BP.
FC-003-329 FC-003-302 07/18/03 SPARE Y
VT-3 SIS-24 BP FC-003-190 FC-003-286 07/21/03 SPARE Y
VT-3 SIS-24A BP FC-003-191 FC-003.155 07/21/03 SPARE Y
VT-3 SIS-27 BP FC-010-010 FC-010-071 10/06/03 SIS-89A VT-3 SIS-28A BP FC-010-005 FC-010-002 10/05/03 SIS-83 Y
VT-3 SIS-30A BP FC-003-330 FC-003-242 07/10/03 SPARE.
Y.
VT-3 SIS-32A BP FC-010-048 FC-010-039 10/20/03 SPARE V
VT-3 SIS-33-BOTTOM BP FC-010-083 FC-010-037 10/20/03 SPARE Y
V-3 SIS-35-TOP BP FC-010-004 FC-010-046 08/11/03 SIS-35-BOTTOM Y
VT-3 SIS-38 BP FC-010-087 FC-010-034 10/16/03 SPARE Y
VT-3 SIS40-TOP BP FC-010-059 FC-010-029 10/14/03 SPARE y
V-3 SIS42A BP FC-010-007 FC-010-035 10/18/03 SPARE Y
VT-3 SIS43A BP FC-003-184 FC-003-207 07/10/03 SPARE Y
VT-3 SIS45A BP FC-003-197 FC-003-175 07/18/03 SPARE Y
VT-3 SIS49 BP FC-003-199 FC-003-194 07/18/03 RCS-19A-RIGHT V
VT-3 SIS-56 BP FC-003-327 FC-003-166 07/09/03 SPARE Y
VT-3 SIS-57 BP FC-003-323 FC-003-160 07/09103 SPARE Y
VT-3 ASME SECTION XI - 1989 Sheet 7 of 8 1/15St2004
OPPD 444 S. 16TH STREET MALL OMAHA, NE 68102 UNIT 1 COMMERCIAL OPS 09/26/1973 SNUBBERS REPLACED - FORT CALHOUN STATION CYCLE 21 AND 2003 REFUELING OUTAGE FT CALHOUN STATION P.O. BOX 550 FT CALHOUN, NE 68023 SNUBBER - LOCATION I MFG ISIN REMOVEDI SIN INSTALLED IDATE INSTALLEDI LOCATION OF REMOVEDlFUNCTIONAL TESTl EXAMINATIONS SIS-65 BP FC-010-039 FC-010-058 10/09103 SIS-32A y
Vr-3 SIS-68 BP FC-010-029 FC-010-089 10/08/03 SIS-40-TOP y
VT-3 SIS-71A BP FC-003-342 FC-003-276 07/14/03 SPARE Y
VT-3 SIS-74A BP FC-003-347 FC-003-289 07/14/03 SPARE Y
VT-3 SIS-78 BP FC-003-348 FC-003-154 07/11/03 SPARE VT-3 SIS-81A BP FC-003-341 FC-003-131 08/06103 SPARE Y
VT-3 SIS-81B BP FC-003-132 FC-003-234 08/13/03 SPARE y
VT-3 SIS-83 BP FC-010-035 FC-010-005 10/09/03 SIS-42A Y
VT-3 SIS-85A BP FC-010-046 FC-010-049 07/17/03 SIS-35-TOP y
VT-3.
SIS-89A BP FC-010-037 FC-010-010 10/12/03 SIS-33-BOTTOM Y
VT-3 SIS-95 BP FC-010-034 FC-010-056 10/09/03 SIS-38 Y
VT-3 SIS-118A BP FC-010-044 FC-010-006 09/16/03 SIS-164 Y
VT-3 SIS-122A BP FC-010-058 FC-010-022 09/29/03 SIS-65 Y
VT-3 SIS-129 BP FC-003-268 FC-003-285 09/20/03 SPARE y
VT-3 SIS-164 BP FC-010-002 FC-010-044 09/27/03 SIS-28A y
VT-3 SIS-165A-BOTTOM BP FC-003-107 FC-003-310 09/14/03 SPARE Y
VT-3 SIS-168 BP FC-003-013 FC-003-156 09/14/003 SPARE Y
VT-3 SIS-169A BP FC-003-225 FC-003-247 07/09/03 SPARE Y
VT-3 SIS-170 BP FC-003-203 FC-003-306 07/09/03 SPARE Y
VT-3 SIS-170A BP FC-010-006 FC-010-023 07/17/03 SIS-118A Y
VT-3 SIS-188 BP FC-003-109 FC-003-309 07/11/03 SPARE y
VT-3 WDS-289 BP FC-003-280 FC-003-187 09/16103 SPARE Y
VT-3 ASME SECTION X - 1989 Sheet 8 of 8 1/15/2004