MONTHYEARL-2024-132, 2024 Population Update Analysis2024-08-13013 August 2024 2024 Population Update Analysis L-2024-129, Relief Request (RR) 14. Limited Coverage Exams Due to Impractical Inservice Inspection Requirements - Fourth Ten-Year Inservice Inspection Program Interval2024-08-0707 August 2024 Relief Request (RR) 14. Limited Coverage Exams Due to Impractical Inservice Inspection Requirements - Fourth Ten-Year Inservice Inspection Program Interval L-2024-121, Subsequent License Renewal Commitment 30 Revision2024-07-30030 July 2024 Subsequent License Renewal Commitment 30 Revision L-2024-123, Submittal of In-Service Inspection Program Owners Activity Report (OAR-1)2024-07-29029 July 2024 Submittal of In-Service Inspection Program Owners Activity Report (OAR-1) L-2024-125, Notice of Intent to Provide Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes2024-07-24024 July 2024 Notice of Intent to Provide Supplemental Information to License Amendment Request to Adopt Common Emergency Plan with Site-Specific Annexes L-2024-110, Environmental Protection Plan Report, Unusual or Important Environmental Event - Manatee in Intake2024-07-10010 July 2024 Environmental Protection Plan Report, Unusual or Important Environmental Event - Manatee in Intake L-2024-114, Quality Assurance Topical Report (FPL-1 Revision 31 Annual Submittal2024-07-10010 July 2024 Quality Assurance Topical Report (FPL-1 Revision 31 Annual Submittal L-2024-109, Schedule for Subsequent License Renewal Environmental Review2024-07-0303 July 2024 Schedule for Subsequent License Renewal Environmental Review L-2024-104, Response to Request for Additional Information, St. Luce Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1 Extension of Inspection Interval for Reactor Pressure Vessel Welds from 102024-06-26026 June 2024 Response to Request for Additional Information, St. Luce Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1 Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 L-2024-097, Technical Specification Special Report2024-06-20020 June 2024 Technical Specification Special Report L-2024-102, Official Service List Update2024-06-19019 June 2024 Official Service List Update L-2024-090, Revised Steam Generator Tube Inspection Reports2024-06-0404 June 2024 Revised Steam Generator Tube Inspection Reports L-2024-075, Notification of Improved Standard Technical Specifications (ITS) Implementation2024-05-13013 May 2024 Notification of Improved Standard Technical Specifications (ITS) Implementation L-2024-053, License Amendment Request L-2024-053, Updated Spent Fuel Pool Criticality Analysis2024-04-30030 April 2024 License Amendment Request L-2024-053, Updated Spent Fuel Pool Criticality Analysis L-2024-071, Cycle 27 Core Operating Limits Report2024-04-29029 April 2024 Cycle 27 Core Operating Limits Report L-2024-070, Cycle 32 Core Operating Limits Report2024-04-29029 April 2024 Cycle 32 Core Operating Limits Report L-2024-056, Annual Radiological Environmental Operating Report for Calendar Year 20232024-04-17017 April 2024 Annual Radiological Environmental Operating Report for Calendar Year 2023 L-2024-064, Florida Power & Light Company - 10 CFR 50.46 - Emergency Core Cooling System SBLOCA 30-Day Report2024-04-17017 April 2024 Florida Power & Light Company - 10 CFR 50.46 - Emergency Core Cooling System SBLOCA 30-Day Report L-2024-054, 2023 Annual Environmental Operating Report2024-04-0909 April 2024 2023 Annual Environmental Operating Report L-2024-047, Proposed Use of a Subsequent ASME Code Edition and Addenda2024-03-28028 March 2024 Proposed Use of a Subsequent ASME Code Edition and Addenda L-2024-045, Report of 10 CFR 72.48 Plant Changes2024-03-27027 March 2024 Report of 10 CFR 72.48 Plant Changes L-2024-011, and Point Beach, Units 1 and 2 - 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2024-03-13013 March 2024 and Point Beach, Units 1 and 2 - 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2024-023, Unusual or Important Environmental Event - Turtle Mortality2024-03-0606 March 2024 Unusual or Important Environmental Event - Turtle Mortality L-2024-015, 2023 Annual Radioactive Effluent Release Report2024-02-29029 February 2024 2023 Annual Radioactive Effluent Release Report L-2024-029, 2023 Annual Operating Report2024-02-28028 February 2024 2023 Annual Operating Report L-2024-026, Revised Reactor Vessel Materials Surveillance Capsule Withdrawal Schedules2024-02-27027 February 2024 Revised Reactor Vessel Materials Surveillance Capsule Withdrawal Schedules L-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2024-004, Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years2024-01-18018 January 2024 Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years L-2024-002, Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2024-01-0808 January 2024 Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-173, Quality Assurance Topical Report (FPL-1) Revision 30 Update2023-12-15015 December 2023 Quality Assurance Topical Report (FPL-1) Revision 30 Update L-2023-179, Unusual or Important Environmental Event - Turtle Mortality2023-12-14014 December 2023 Unusual or Important Environmental Event - Turtle Mortality L-2023-168, License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 52023-12-12012 December 2023 License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 5 L-2023-155, Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-06542023-11-28028 November 2023 Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, L-2023-162, Response to 50.69 2nd Round of Rals2023-11-21021 November 2023 Response to 50.69 2nd Round of Rals L-2023-131, Subsequent License Renewal Application - Second Annual Update2023-09-28028 September 2023 Subsequent License Renewal Application - Second Annual Update L-2023-136, Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-26026 September 2023 Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-122, Corrections to the 2022 Annual Radiological Environmental Operating Report2023-09-20020 September 2023 Corrections to the 2022 Annual Radiological Environmental Operating Report L-2023-127, Correction to the 2022 Annual Radioactive Effluent Release Report2023-09-18018 September 2023 Correction to the 2022 Annual Radioactive Effluent Release Report L-2023-113, Correction to the 2020 Annual Radiological Environmental Operating Report2023-09-14014 September 2023 Correction to the 2020 Annual Radiological Environmental Operating Report L-2023-118, Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-11011 September 2023 Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-108, Report of 10 CFR 50.59 Plant Changes2023-09-11011 September 2023 Report of 10 CFR 50.59 Plant Changes L-2023-107, Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.42023-09-0606 September 2023 Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.4 L-2023-112, Corrections to the 2021 Annual Radioactive Effluent Release Report2023-09-0606 September 2023 Corrections to the 2021 Annual Radioactive Effluent Release Report L-2023-114, Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update2023-08-17017 August 2023 Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update L-2023-098, and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22023-08-0707 August 2023 and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2023-105, Preparation and Scheduling of Operator Licensing Examinations2023-08-0303 August 2023 Preparation and Scheduling of Operator Licensing Examinations L-2023-102, Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches2023-07-26026 July 2023 Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches L-2023-099, Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2023-07-26026 July 2023 Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-097, Subsequent License Renewal Application Revision 1 - Supplement 62023-07-13013 July 2023 Subsequent License Renewal Application Revision 1 - Supplement 6 L-2023-076, In-Service Inspection Program Owner'S Activity Report (OAR-1)2023-07-11011 July 2023 In-Service Inspection Program Owner'S Activity Report (OAR-1) 2024-08-07
[Table view] |
Text
lm REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
DISTRIBUTION FOR INCOMING MATERIAL 50-335 REC: REID R W ORG: UHRIG R E DOCDATE: 04/21/78 NRC FL PNR 5 LIGHT DATE RCVD: 04/26/7 DOCTYPE: LETTER NOTARIZED: NO COPIES RECEIVED
SUBJECT:
LTR 3 ENCL 3 FORWARDING APPLICANT"S OUTLINES OF SUBJECT FACILITY) UNIT 1 CEA GUIDE TUBE SLEEVING PROCEDURES... AND ADVISING OF APPLICANT"S INTENTIONS TO SUBMITT COMBUSTION-ENGR REPT CEN-90(F)-P BY 04/28l78.
PLANT NAME: ST LUCIE Oi REVIEWER INITIAL: X JM DISTRIBUTOR INITIAL:~
+>~>>+++4+4+>++++ DISTRIBUTION OF THIS MATERIAL IS AS FOLLOWS ++++++>++>>>~>+>>>
GENERAL DISTRIBUTION FOR AFTER ISSUANCE OF OPERATING LICENSE.
(DISTRIBUTION CODE A001)
FOR ACTION: BR CHIEF REID44W/7 ENCL INTERNAL: REG FILE+4 NRC PDR+4W/ENCL
++M/2 ENCL OELD%4LTR ONLY HANAUER44W/ENCL CHECK+4W/ENCL E I SENHUT++W/ENCL SHAO++W/ENCL BAER%4W/ENCL BUTLER44W/ENCL EEB++W/ENCL J COLLINS+>W/ENCL J. MCGOUGH+<W/ENCL EXTERNAL: LPDR S FT PIERCEi FL+4W/ENCL TIC+4W/ENCL NSI C++W/ENCL ACRS CAT 8+4W/16 ENCL DISTRIBUTION: LTR 40 ENCL 39 CONTROL NBR: 781160 45 SIZE: 1 P+2P THE END
~ ~
,t f + y 1, I fl 1>>,
r I'I ' tl f 1
I
$ f- ~ tr r'>> f wfr"" ' 1
~ tt r I "I t
>>V It >>
1 I
I Vff 1 wr '" t 1,'VI>>>>$ t;,$ f'J," I f P)1 r 1>>
fw 4
t t
Iw 1r w r t It
~ w" h
It tt 1 1>> >>I
>>V
~f .w 1 l ),, 1, ft'I "IV II
~,
1
~ 1
~ 1 lw f l 1 t V') I >>'f. f~ j If fr 1 1
~,- )
w'
'I
FLORIDA POWER & LIGHT COMPANY April 21, 1978 L-7 8-3.4 4 Office of Nuclear Reactor Regulation Attention: Mr. R. W. Reid, Director Operating Reactors Branch I4 Division of Operating Reactors U. S. Nuclear Regulatory Commission Washington, D. C. 20555 t rn
Dear Mr. Reid:
cnrn nl~
Re: St. Lucie Unit 1 'C~
Docket No. 50-335 ~en@~ Cn ~
CEA Guide Tube Sleevin r> @
The attached information outlines the St. Lucie UnZt 1 CPA ~5 guide tube sleeving procedures. The procedures describIe're w essentially those that, have been used on the Ca lvert Cliffs-1 and Millstone-2 fuel assemblies.
Within the next few days we expect to receive Combustion-Engineering's report CEN-90(F)-P, "St. Lucie Unit 1 Reactor Operation with Modified CEA Guide Tubes." The report will be similar to the reports for Calvert Cliffs-1 and Millstone-2.
We anticipate forwarding the report to your office by April 28, 1978. We will advise you of any change.'in our schedule.
Very truly yours, Robert E. Uhrig Vice President REU/MAS/mb Attachment.
cc: Mr. James P. O'Reilly, Region II Harold F. Reis, Esctuire 78ii60i45 Y(,
PEOPLE .. ~ SERVING PEOPLE
V OI
- ~
J
'K
'J E
C "J E
ATTACHMENT Re: St. Lucie Unit 1 Docket No. 50-335 CEA Guide Tube Sleevin OUTLINE OF SLEEVING PROCEDURES I. Dry sleeving in new fuel racks A. Sleevin Installation Once an assembly is chosen for sleeving, a guide tube inspection tool will be used to check the guide tubes for interferences which would hamper sleeve insertion.
If no'interference is found, a sleeve will be placed in each of the five guide tubes. A sleeve tamping too1 will then be used to push the sleeve into the guide tube.
Guide Tube Ex ansion A guide tube expansion tool, suspended from a load ce11, will be lowered into the guide tube a specified distance. The guide tube, sleeve 'will then be expanded into the guide tube by using a hydraulic expansion tool. The expansion tool will be carefully lifted out of the guide Cube while monitoring the load cell reading.
C. Sleeve Ex ansion A sleeve expansion tool', suspended from a load cell, vill be lowered into the guide t'ube a specified distance. The guide tube sleeve, will then be expanded into the guide tube by using'a hydraulic expansion tool. Following the first expansion, the expansion tool will be raised one inch and the expansion sequence repeated. Following the second expansion, three more expansion operations will be performed, with each one being one inch above the previous expansion. The expansion tool will be carefully li;fted out, of the guide tube whi1e monitoring the load cell reading.
Immediately following insta1lation of the five sleeves in an assembly, the potential for interference with CEA. motion will be checked with a full length sleeve gauge and then with a five-finger CEA checking tool.
Each sleeve will then be tested for resistance to a specified withdrawal load by using a sleeve withdrawal tool and load cell.
r r
4
,V1 t
1 1
l
'r l l lt I
r f.
h
Page Two Re: St. Iucie Untt 1 Docket No. 50-335 CEA Guide Tube Sleevin IX. Wet sleeving in spent fuel pool. Underwater lights and a TV camera will be used for monitoring underwater operations.
A. CEA Removal (if necessar )
A CEA removal tool, suspended from a load cell, will be used assembly.
to carefully lift the CEA out of the fuel CEAs,will be temporarily stored in fuel assemblies not designated for sleeving and will be reinserted in the proper assemblies according to the Cycle 2 1oading pattern.
B. Sleevin Installation Same as for dry sleeving.
C. Guide Tube Ex ansion Same as for dry sleeving.
D. Sleeve Ex ansion Same as for dry sleeving except. there will be only three expansion sequences instead of five.
k 0
(I 1
I I
,/