L-2006-088, Core Operating Limits Report

From kanterella
(Redirected from L-2006-088)
Jump to navigation Jump to search
Core Operating Limits Report
ML060960399
Person / Time
Site: Turkey Point 
Issue date: 03/29/2006
From: Jones T
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2006-088
Download: ML060960399 (4)


Text

FPIZ FF31.MAR 2 9 2006 L-2006-088 10 CFR 50.36 U.S. Nuclear Regulatory Commission Attn: Dccument Control Desk Washington, D. C. 20555 Re:

Turkey Point Unit 3 Docket No. 50-250 Core Operating Limits Report In accordance with Technical Specification 6.9.1.7, the attached Core Operating Limits Report is provided for Turkey Point Unit 3. These curves are applicable for Unit 3 Cycle 22.

Should there be any questions, please contact Walter Parker, Licensing Manager, at 305-246-6632.

Very truly yours, Terry

. Jones Site Vice President Turkey Point Nuclear Plant OIH Attachment cc:

Regional Administrator, Region II, USNRC Eenior Resident Inspector, USNRC, Turkey Point Plant an FPL Group company

Attachment to L-2006-088 Page 1 of 3 CORE OPERATING LIMITS REPORT - UNIT 3 CYCLE 22 The Technical Specifications (TS) affected by this report are:

3.1.3.2 Analog Rod Position Indication System 3.1.3.6 Control Rod Insertion Limits 3.2.1 Axial Flux Difference (AFD) 3.2.2 Heat Flux Hot Channel Factor - FQ(Z) 3.2.3 Nuclear Enthalpy Rise Hot Channel Factor - FAH The Control Rod Insertion Limits, AFD, FQ(Z), K(Z), and FAH have been developed using the NRC approved methodology specified in TS 6.9.1.7.

TS 3.1.3.2 Analog Rod Position Indication System The All Rods Out position for all Shutdown Banks and Control Banks is defined to be 2.30 steps withdrawn.

TS 3.1.3.6 Control Rod Insertion Limits The control rod banks shall be limited in physical insertion as shown on Figure 1 for All Rods Out = 230 steps withdrawn.

TS 3.2.1 Axial Flux Difference The AFD limits are provided on Figure 2.

TS 3.2.2 Heat Flux Hot Channel Factor - FQ(Z)

[Q] L = 2.50 K(Z) = 1.0 for 0 ft. < Z < 12 ft. where Z = core height.

TS 3.2.3 Nuclear Enthalpy Rise Hot Channel Factor FRTP = 1.70 P.FAH = 0.3

Attachment to L-2006-088 P-I

^f o Figure 1 Turkey Point Unit 3 - Cycle 22 Rod Insertion Limits vs Thermal Power ARO = 230 Steps Withdrawn. OverlaD = 102 Steps 230 220 210 200

-190 3 180 X

170 316C V 15c 14C r

13C e

12C X0 110 0< l oc 0

9C 8C 7C 6C 5C 34(

2(

30)

-3

) -

- _----v 7_

7 I

_7

00==_)-

, I J

I I X

I II.

I I

I 0

10 20 30 40 50 60 70 80 90 100 Percent Reactor Power

Pagtth ent tn o 3-94-MR Page 3 of 3 120 100 0a-

-J wM I--

0 C) 10a-80 60 40 Figure 2 Axial Flux Difference as a Function of Rated Thermal Power Tukev Point Unit 3 - Cvcle 22

(-1.100)

(+7,10.

UINA CCM~ABLE~

U. ACCEPTA ILE OP-RATION OPERATIO

--- :.1 0

0-..Q.

\\

I An 1

- l

-. NC ETAL. -:/ -...0 050

\\I

-U ACCEPTABLE~

CERTIN -/ :.. )i-
T-----OPERATION :

20 0

-50

-40

-30

-20

-10 0

10 20 30 40 50 Axial Flux Difference (%)