L-2004-050, Annual Radioactive Effluent Release Report

From kanterella
(Redirected from L-2004-050)
Jump to navigation Jump to search
Annual Radioactive Effluent Release Report
ML040690880
Person / Time
Site: Saint Lucie  
Issue date: 02/27/2004
From: Jefferson W
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2004-050
Download: ML040690880 (42)


Text

FPL Florida Power & Light Company, 6501 S. Ocean Drive. Jensen Beach, FL 34957 February 27, 2004 L-2004-050 10 CFR 50.36 10 CFR 50.36a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:

St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 2003 Annual Radioactive Effluent Release Report Attached is the 2003 Annual Radioactive Effluent Release Report for St. Lucie Units 1 and 2. This report is being sent pursuant to 10 CFR 50.36a(a)(2) and Technical Specification (TS) 6.9.1.7. The report is for the 12-month period beginning January 1, 2003 and ending December 31, 2003.

Attachment A of the report is a summary of the June 12, 2003 unplanned release of the Unit 2 gas decay tank 2C event.

There were no revisions to the Offsite Dose Calculation Manual (ODCM).

Therefore, the ODCM will not be included in this submittal.

Please contact us with any questions regarding this submittal.

Vice Presrdent St. Lucie Plant WJ/spt Attachments

- an FPL Group company

TABLE OF CONTENTS DESCRIPTION PAGE EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION.

VISITOR DOSE RESULTS FOR CALENDAR YEAR..............................

OFFSITE DOSE CALCULATION MANUAL REVISIONS.............................

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS..............................

PROCESS CONTROL PROGRAM REVISIONS......................................

LIQUID EFFLUENTS:

I 6

6 6

6 Summation of all Releases Summation of all Releases Nuclide Summation by Quarter Nuclide Summation by Quarter Liquid Effluent Dose Liquid Effluent Dose Unit #1....................................

Unit#2...................................

Unit # 1..................................

Unit # 2..................................

Unit # 1..................................

Unit#2..................................

7 9

20 15 19 20 GASEOUS EFFLUENT:

Summation of all Releases Summation of all Releases Nuclide Summation by Quarter Nuclide Summation by Quarter Gas Effluent Dose Gas Effluent Dose Unit #1....................................

Unit#2...................................

Unit # 1..................................

Unit # 2..................................

Unit # 1..................................

Unit#2..................................

21 23 25 29 33 34 SOLID WASTE DISPOSAL - TABLE 3.9 Shipment Summations.................

Attachment - A UNPLANNED RELEASE of Gas Decay Tank 2C 35 39 Attachment - B Offsite Dose Calculation Manual (C-200)

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION

1. Regulatory Limits 1.1 For Liquid Waste Effluents A. The concentration of radioactive material released from the site shall be limited to 10 times the concentrations specified in 10 CFR Part 20 Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 micro-Curies/ml total activity.

B. The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive material in liquid effluents released, from each reactor unit, to UNRESTRICTED AREAS shall be limited to:

During any calendar quarter to <= 1.5 mrems to the Total Body and to <= 5 mrems to any organ, and During any calendar year to

<= 3 mrems to the Total Body and to <= 10 mrems to any organ.

1.2 For Gaseous Waste Effluents:

A. The dose rate in UNRESTRICTED AREAS due to radioactive materials released in gaseous effluents from the site shall be limited to:

For Noble Gases: <= 500 mrems/yr to the total body and

<= 3000 mrems/yr to the skin, and For Iodine-131, Iodine-133, Tritium, and all radionuclides in particulate form with half-lives greater than 8 days:

<= 1500 mrems/yr to any organ.

  • B. The air dose due to noble gases released in gaseous effluents from each unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following:

During any calendar quarter, to <= 5 mrads for gamma radiation, and

<= 10 mrads for beta radiation and, during any calendar year, to <= 10 mrads for gamma radiation and

<= 20 mrads for beta radiation.

  • C. The dose to a MEMBER OF THE PUBLIC from lodine-131, Iodine-133, Tritium, and all radionuclides in particulate form, with half-lives > 8 days in gaseous effluents released, from each unit to areas at and beyond the site boundary, shall be limited to the following:

During any calendar quarter to <= 7.5 mrem to any organ, and During any calendar year to

<= 15 mrem to any organ.

  • The calculated doses contained in an annual report shall not apply to any ODCM Control. The reported values are based on actual release conditions instead of historical conditions that the ODCM Control dose calculations are based on. The ODCM Control dose limits are therefore included in Item 1 of the report, for information only.

1

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION (Continued)

2. Effluent Concentration Limits (ECL)

Water: Ten times the 10 CFR Part 20, Appendix B, Table 2, Column 2, except for entrained or dissolved noble gases as described in 1.1.A of this report.

Air:

Release concentrations are limited to dose rate limits described in 1.2.A. of this report.

3. Average energy of fission and activation gases in gaseous effluents is not applicable.
4. Measurements and approximations of total radioactivity Where alpha, tritium, and listed nuclides are shown as zero Curies released, this should be interpreted as "no activity was detected on the samples using the ODCM Control analyses techniques to achieve required Lower Limit of Detection (LLD) sensitivity for radioactive effluents."

A summary of liquid effluent accounting methods is described in Table 3.1.

A summary of gaseous effluent accounting methods is described in Table 3.2.

4.1 Estimate of Errors LIQUID 1

GASEOUS Error Topic Avg %

Max %

Avg %

Max %

Release Point Mixing 2

5 NA NA Sampling 1

5 2

5 Sample Preparation 1

5 1

5 Sample Analysis 3

10 3

10 Release Volume 2

5 4

15 Total Percent 9

30 10 35 The predictability of error for radioactive releases can only be applied to nuclides that are predominant in sample spectrums.

Nuclides that are near background relative to the predominant nuclides in a given sample could easily have errors greater than the above listed maximums.

2

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION (Continued)

4. Measurements and Approximations of Total Radioactivity (Cont.)

4.2 Methods of Analyses TABLE 3.1 RADIOACTIVE LIQUID EFFLUENT SAMPLING AND ANALYSIS Liquid Sampling Method of Source Frequency Type of Analysis Analysis Each Batch Principal Gamma Emitters p.h.a.

Monitor Monthly Tritium L.S.

Tank Composite Gross Alpha AIC Releases Quarterly Sr-89, Sr-90, Composite

& Fe-55 C.S.

Continuous Daily Principal Gamma Emitters Releases Grab

& 1-131 for p.h.a.

Samples 4/M Composite Analysis Dissolved & Entrained Gases One Batch/ Month p.h.a.

Tritium Composite Monthly L.S.

Alpha Composite Monthly AIC Sr-89, Sr-90, & Fe-55 Composite Quarterly C.S.

p.h.a.-

L.S.-

C.S.-

AIC 4/M -

Gamma Spectrum Pulse Height Analysis using Germanium Detectors. All peaks are identified and quantified.

Liquid Scintillation Counting Chemical Separation Air Ion Chamber Four per Month 3

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION (Continued)

4. Measurements and Approximations of Total Radioactivity (Continued) 4.2 Methods of Analyses(Continued)

TABLE 3.2 RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS Gaseous Sampling Method of Source Frequency Type of Analysis Analysis Waste Gas Decay Tank Each Batch Principal Gamma Emitters p.h.a.

Releases Containment Principal Gamma Emitters p.h.a Purge Each Purge Releases Tritium L.S.

4/M Principal Gamma Emitters p.h.a.

Tritium L.S.

Plant Weekly Particulate Vent Analysis Gross Alpha AIC Quarterly Particulate

__________Composite Sr-89 & Sr-90 C.S.

p.h.a.- Gamma Spectrum Pulse Height Analysis using Germanium Detectors. All peaks are identified and quantified.

L.S.-

Liquid Scintillation Counting C.S.- Chemical Separation AIC.- Air Ion Chamber 4/M -

Four per Month 4

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # I & 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION (Continued)

5. Batch Releases lA. Liquid Unit 1 l

Unit 2 Eng. Unit

1. Number of batch releases 35 34 l_

l

2. Total time period for batch releases 21,560 20,952 minutes
3. Maximum time period for a batch release 2,130 2,130 minutes
4. Average time period for a batch release 625 625 minutes
5. Minimum time period for a batch release 260 260 minutes
6. Average dilution stream flow during the period 971,367 971,367 gpm All liquid releases are summarized in Tables lB. Gaseous Unit 1 l Unit 2 Eng. Unit
1. Number of batch releases 2 J 101
2. Total time period for batch releases 205 17,810 minutes
3. Maximum time period for a batch release 156 7,790 minutes
4. Average time period for a batch release 103 178 minutes
5. Minimum time period for a batch release 49 30 minutes All gaseous waste releases are summarized in Tables
6. Unplanned Releases A. Liquid I

Unit 1 l

Unit2 l Eng. Unit I

1. Number of releases 0

0

2. Total activity of releases

___.__E+0_

0.OOE+001 Curies B. Gaseous Unit 1 l

Unit 2 l Eng. Unitl

1. Number of releases 0

X1

2. Total activity of releases 0.OOE+00 8.77E&03 Curies C. See Attachment - A for Unit 2 Unplanned Gas Release
1. A description of the event and equipment involved.
2. Cause(s) for the unplanned release.
3. Actions taken to prevent a recurrence.
4. Consequences of the unplanned release.

5

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION (Continued)

7. Assessment of radiation dose from radioactive effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY assumes the VISITOR onsite for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> per day for 312 days per year at a distance of 1.6 kilometers in the South East Sector. The VISITOR received exposure from each of the two reactors on the site. Actual Met Data was used to calculate Visitor Dose for Calendar Year 2003.

VISITOR DOSE RESULTS FOR CALENDAR YEAR 2003 were:

NOBLE GAS Gamma Air Dose Beta Air Dose DOSE mrad 5.08E-04 2.65E-04 Gas Particulate

& Iodine Dose Bone Liver Thyroid Kidney Lung GI-LLI Total Body Dose mrem 1.06E-05 5.01 E-04 5.94E-04 5.OOE-04 4.99E-04 5.00E-04 5.02E-04

8. Offsite Dose Calculation Manual(ODCM) Revision(s):

There were no revisions made during the reporting interval.

9. Solid Waste and Irradiated Fuel Shipments:

No irradiated fuel shipments were made from the site.

Common solid waste from St. Lucie Units 1 and 2 were shipped jointly.

A tabulated summation of these shipments is provided in this report as Table 3.9.

10. Process Control Program (PCP) Revisions:

There were no changes during the reporting interval.

11. Major Changes to Radioactive Liquid, Gaseous and Solid Waste Treatment Systems:

There were no changes during the reporting interval.

6

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # I ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.3-1 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES UNIT QTR#I QTR#2 A. Fission and Activation Products

1. Total Release - (Not including Tritium, Gases, and Alpha)
2. Average Diluted Concentration During Period Ci uCi/mI 1.46E-02 2.90E-1 I 1.98E-02 4.92E-I I B. Tritium
1. Total Release Ci
2. Average Diluted Concentration During Period uCi/ml C. Dissolved and Entrained Gases
1. Total Release Ci
2. Average Diluted Concentration During Period uCi/ml D. Gross Alpha Radioactivity
1. Total Release Ci E. Volume of Waste Released (Prior to Dilution)

Liters F. Volume of Dilution Water Used During Period Liters (a) - Denotes this value includes 2.51E+07 Liters from one release from the site (for hurricane preparations).

7 2.84E+02 1.45E+02 5.65E-07 3.611E-07 2.40E-03 2.26E-02 4.76E-12 5.62E-11 O.OOE+00 O.OOE+00 (a) 6.95E+05 2.78E+07 5.03E+1 1 settling pond 4.02E+1 I

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # I ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.3-1 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES (Continued)

UNIT QTR#3 QTR#4 A. Fission and Activation Products

1. Total Release - (Not including Tritium, Gases, and Alpha)
2. Average Diluted Concentration During Period Ci uCi/ml 4.38E-03 7.47E-03 8.52E-12 1.45E-11 B. Tritium
1. Total Release
2. Average Diluted Concentration During Period C. Dissolved and Entrained Gases
1. Total Release
2. Average Diluted Concentration During Period D. Gross Alpha Radioactivity
1. Total Release E. Volume of Waste Released (Prior to Dilution)

F. Volume of Dilution Water Used During Period Ci 4.73E+01 7.55E+01 uCi/mI Ci uCi/mI 9.19E-08 3.89E-04 7.56E-13 1.47E-07 5.93E-03 1.15E-1 l Ci O.OOE+00 O.OOE+00 Liters Liters 3.90E+05 6.57E+05 5.14E+11 5.15E+11 8

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.3-2 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES UNIT QTR#l QTR#2 A. Fission and Activation Products

1. Total Release - (Not including Tritium, Gases, and Alpha)
2. Average Diluted Concentration During Period Ci uCi/ml 1.46E-02 2.90E-1 1 1.98E-02 4.92E-1I B. Tritium
1. Total Release
2. Average Diluted Concentration During Period Ci 2.84E+02 1.45E+02 uCi/ml 5.65E-07 3.61E-07 C. Dissolved and Entrained Gases
1. Total Release Ci 2.40E-03 2.26E-02 4.76E-12 5.62E-ll
2. Average Diluted Concentration During Period uCi/ml D. Gross Alpha Radioactivity
1. Total Release E. Volume of Waste Released (Prior to Dilution)

F. Volume of Dilution Water Used During Period Ci Liters Liters 0.OOE+00 0.OOE+00 6.95E+05 1.37E+06 5.03E+1I 4.02E+1 I 9

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.3-2 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES (Continued)

UNIT QTR#3 QTR#4 A. Fission and Activation Products

1. Total Release - (Not including Tritium, Gases, and Alpha)
2. Average Diluted Concentration During Period Ci uCi/ml 4.38E-03 7.47E-03 8.52E-12 1.45E-1 I B. Tritium
1. Total Release
2. Average Diluted Concentration During Period C. Dissolved and Entrained Gases
1. Total Release
2. Average Diluted Concentration During Period D. Gross Alpha Radioactivity
1. Total Release E. Volume of Waste Released (Prior to Dilution)

F. Volume of Dilution Water Used During Period Ci uCi/ml Ci uCi/ml 4.73E+01 7.55E+01 9.19E-08 3.89E-04 7.56E-13 1.47E-07 5.93E-03

1. 15E-1 I Ci O.OOE+00 O.OOE+00 Liters Liters 3.90E+05 6.57E+05 5.14E+11 5.15E+1 I 10

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # I ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.4-1 LIQUID EFFLUENTS NUCLIDES Continuous Mode Batch Mode RELEASED UNIT QTR#1 QTR#2 QTR#1 QTR#2 Na-24 Ci 0.OOE 00 0.00E 00 O.OOE+00 0.00E+00 Cr-51 Ci 0.OOE 00 0.OOE 00 4.OOE-04 8.15E-04 Mn-54 Ci 0.OOE 00 0.00E 00 9.45E-05 1.10E-04 Fe-55 Ci 0.OOE 00 0.00E 00 1.OOE-02 8.25E-03 Mn-56 Ci 0.00E 00 0.00E 00 0.OOE+00 0.00E+00 Co-57 Ci 0.00E 00 0.00E 00 O.OOE+00 1.17E-05 Co-58 Ci 0.00E 00 0.OOE 00 1.26E-03 2.89E-03 Fe-59 Ci 0.OOE 00 O.OOE 00 1.48E-04 0.OOE+00 Co-60 Ci 0.00E 00 0.OOE 00 8.96E-04 2.15E-03 Zn-65 Ci 0.OOE 00 0.OOE 00 0.OOE+00 0.OOE+00 Ni-65 Ci 0.00E 00 0.OOE 00 0.OOE+00 0.OOE+00 Br-82 Ci 0.OOE 00 0.OOE 00 0.OOE+00 0.OOE+00 Rb-88 Ci 0.OOE 00 0.OOE 00 0.00E+00 0.OOE+00 Sr-89 Ci 0.00E 00 0.OOE 00 9.74E-06 0.00E+00 Sr-90 Ci 0.OOE 00 0.OOE 00 0.00E+00 1.13E-04 Y-90 Ci 0.OOE 00 0.OOE 00 0.OOE+00 1.13E-04 Sr-91 Ci 0.OOE 00 0.OOE 00 0.OOE+00 0.OOE+00 Sr-92 Ci 0.OOE 00 0.OOE 00 0.00E+00 0.OOE+00 Y-92 Ci 0.OOE 00 0.OOE 00 0.OOE+00 0.OOE+00 Zr-95 Ci 0.OOE 00 0.OOE 00 5.80E-05 7.37E-05 Nb-95 Ci 0.OOE 00 0.OOE 00 1.50E-04 2.12E-04 Zr-97 Ci 0.OOE 00 0.OOE 00 0.OOE+00 0.OOE+00 Nb-97 Ci 0.OOE 00 0.OOE 00 8.80E-06 3.39E-04 Tc-99m Ci 0.OOE 00 0.OOE 00 0.OOE+00 0.OOE+00 Mo-99 Ci 0.OOE 00 0.OOE 00 0.OOE+00 6.54E-04 Ru-103 Ci 0.OOE 00 0.OOE 00 0.OOE+00 0.OOE+00 Ag-I 10 Ci 0.OOE 00 0.OOE 00 0.OOE+00 1.86E-04 Sn-1 13 Ci 0.OOE 00 0.OOE 00 6.48E-05 1.20E-05 Sb-122 Ci 0.OOE 00 0.OOE 00 0.OOE+00 0.OOE+00 Sb-124 Ci 0.OOE 00 0.OOE 00 0.OOE+00 1.86E-04 Sb-125 Ci 0.OOE 00 0.OOE 00 1.39E-03 3.38E-03 11

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 1 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.4-1 LIQUID EFFLUENTS (Continued)

NUCLIDES RELEASED Continuous Mode UNIT QTR#1 QTR#2 Batch Mode QTR#1 QTR#2 Te-129 Te-129m I-130 1-131 Te-132 1-132 I-133 1-134 Cs-134 I-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 TOTAL FOR PERIOD Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE+00 O.OOE+00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE 00 O.OOE 00 Ci O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 4.87E-05 O.OOE+00 O.OOE+00 7.84E-05 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 1.46E-02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2.40E-03 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 1.05E-05 O.OOE+00 9.80E-06 O.OOE+00 O.OOE+00 1.99E-04 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 4.78E-05 O.OOE+00 O.OOE+00 O.OOE+00 1.98E-02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 1.41 E-04 2.24E-02 1.95E-05 1.34E-05 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 12

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 1 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.4-1 LIQUID EFFLUENTS (Continued)

NUCLIDES RELEASED Na-24 Cr-51 Mn-54 Fe-55 Mn-56 Co-57 Co-58 Fe-59 Co-60 Zn-65 Ni-65 Br-82 Rb-88 Sr-89 Sr-90 Y-90 Sr-91 Sr-92 Y-92 Zr-95 Nb-95 Zr-97 Nb-97 Tc-99m Mo-99 Ru-103 Ag-110 Sn-113 Sb-122 Sb-124 Sb-125 UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Continuous Mode QTR#3 QTR#4 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 O.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 Batch Mode QTR#3 QTR#4 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 2.26E-05 1.57E-05 2.08E-03 4.05E-03 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 4.55E-04 1.45E-04 0.OOE 00 0.OOE 00 3.8 1E-04 9.29E-04 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 8.20E-06 4.60E-06 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 9.65E-05 1.57E-04 0.OOE 00 0.OOE 00 4.02E-05 2.47E-05 3.65E-05 2.79E-05 0.OOE 00 0.OOE 00 2.14E-05 3.02E-05 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 5.86E-05 0.OOE 00 2.02E-05 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 1.03E-03 1.83E-03 13

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 1 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.4-1 LIQUID EFFLUENTS (Continued)

NUCLIDES RELEASED Te-129 Te-129m I-130 1-131 Te-132 1-132 1-133 I-134 Cs-134 1-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 WV-187 Np-239 TOTAL FOR PERIOD UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Continuous Mode QTR#3 QTR#4 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 O.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 Batch Mode QTR#3 QTR#4 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 1.31E-05 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 4.44E-05 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 1.3 1E-04 2.02E-04 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 Ci 0.OOE+00 0.OOE+00 4.38E-03 7.47E-03 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-13 lm Xe-133m Xe-133 Xe-135m Xe-135 Xe-138 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 5.55E-06 3.74E-04 9.20E-06 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 5.93E-03 5.28E-06 0.OOE 00 0.OOE 00 14

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.4-2 LIQUID EFFLUENTS NUCLIDES RELEASED Na-24 Cr-51 Mn-54 Fe-55 Mn-56 Co-57 Co-58 Fe-59 Co-60 Zn-65 Ni-65 Br-82 Rb-88 Sr-89 Sr-90 Y-90 Sr-91 Sr-92 Y-92 Zr-95 Nb-95 Zr-97 Nb-97 Tc-99m Mo-99 Ru-103 Ag-110 Sn-113 Sb-122 Sb-124 Sb-125 UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Continuous Mode QTR#1 QTR#2 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 Batch Mode QTR#1 QTR#2 0.OOE+00 0.OOE+00 4.OOE-04 8.15E-04 9.45E-05 1.IOE-04 1.OOE-02 8.25E-03 0.OOE+00 0.OOE+00 0.OOE+00 1.17E-05 1.26E-03 2.89E-03 1.48E-04 0.OOE+00 8.96E-04 2.15E-03 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 9.74E-06 0.OOE+00 0.OOE+00 1.13E-04 0.OOE+00 1.13E-04 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 5.80E-05 7.37E-05 1.50E-04 2.12E-04 0.OOE+00 0.OOE+00 8.80E-06 3.39E-04 0.OOE+00 0.OOE+00 0.OOE+00 6.54E-04 0.OOE+00 0.OOE+00 0.OOE+00 1.86E-04 6.48E-05 1.20E-05 0.OOE+00 0.OOE+00 0.OOE+00 1.86E-04 1.39E-03 3.38E-03 15

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.4-2 LIQUID EFFLUENTS (Continued)

NUCLIDES RELEASED Continuous Mode UNIT QTR#1 QTR#2 Batch Mode QTR#1 QTR#2 Te-129 Te-129m 1-130 1-131 Te-132 1-132 1-133 I-134 Cs-134 I-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 TOTAL FOR PERIOD Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.00E 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.00E 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE 00 0.OOE 00 Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 4.87E-05 0.OOE+00 0.OOE+00 7.84E-05 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 1.46E-02 0.OOE+00 0.OOE+00 0.0OE+00 0.0OE+00 0.OOE+00 0.OOE+00 0.OOE+00 2.40E-03 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.0OE+00 0.OOE+00 0.OOE+00 I.05E-05 0.OOE+00 9.80E-06 0.OOE+00 0.OOE+00 1.99E-04 0.OOE+00 0.OOE+00 0.0OE+00 0.0OE+00 4.78E-05 0.0OE+00 0.OOE+00 0.OOE+00 1.98E-02 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 1.4 1E-04 2.24E-02 1.95E-05 1.34E-05 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131 m Xe-133m Xe-133 Xe-135m Xe-135 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 16

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.4-2 LIQUID EFFLUENTS (Continued)

NUCLIDES RELEASED Na-24 Cr-51 Mn-54 Fe-55 Mn-56 Co-57 Co-58 Fe-59 Co-60 Zn-65 Ni-65 Br-82 Rb-88 Sr-89 Sr-90 Y-90 Sr-91 Sr-92 Y-92 Zr-95 Nb-95 Zr-97 Nb-97 Tc-99m Mo-99 Ru-103 Ag-I 10 Sn-1 13 Sb-122 Sb-124 Sb-125 UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Continuous Mode QTR#3 QTR#4 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 Batch Mode QTR#3 QTR#4 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 2.26E-05 1.57E-05 2.08E-03 4.05E-03 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 4.55E-04 1.45E-04 O.OOE 00 O.OOE 00 3.8 1E-04 9.29E-04 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 8.20E-06 4.60E-06 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 9.65E-05 1.57E-04 O.OOE 00 O.OOE 00 4.02E-05 2.47E-05 3.65E-05 2.79E-05 O.OOE 00 O.OOE 00 2.14E-05 3.02E-05 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 5.86E-05 O.OOE 00 2.02E-05 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 1.03E-03 1.83E-03 17

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.4-2 LIQUID EFFLUENTS (Continued)

NUCLIDES RELEASED Te-129 Te-129m 1-130 1-131 Te-132 1-132 1-133 1-134 Cs-134 1-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 TOTAL FOR PERIOD UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Continuous Mode QTR#3 QTR#4 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 Batch Mode QTR#3 QTR#4 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 1.31E-05 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 4.44E-05 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 1.3lE-04 2.02E-04 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 4.38E-03 7.47E-03 Ci 0.OOE+00 0.OOE+00 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131 m Xe-133m Xe-133 Xe-135m Xe-135 Xe-138 Ci 0.OOEOO0 Ci 0.OOEOO0 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOEOO0 Ci 0.OOEOO0 Ci 0.OOEOO0 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 5.55E-06 3.74E-04 9.20E-06 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 5.93E-03 5.28E-06 0.OOE 00 0.OOE 00 18

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # I ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.5-1 LIQUID EFFLUENTS - DOSE SUMMATION AGE GROUP:

ADULT LOCATION:

ANY ADULT FISH AND SHELLFISH ORGAN Bone Liver Thyroid Kidney Lung GI-LLI Total Body DOSE mrem 1.25E-02 5.6 1E-02 9.45E-04 9.58E-04 6.53E-02 2.75E-02 1.55E-02 19

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.5-2 LIQUID EFFLUENTS - DOSE SUMMATION AGE GROUP:

ADULT LOCATION:

ANY ADULT FISH AND SHELLFISH ORGAN Bone Liver Thyroid Kidney Lung GI-LLI Total Body DOSE mrem 1.25E-02 5.61 E-02 9.45E-04 9.58E-04 6.53E-02 2.75E-02 1.55E-02 20

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 1 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.6-1 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES UNIT QTR#1 QTR#2 A. Fission and Activation Gases

1. Total Release
2. Average Release Rate For Period Ci uCi/sec 2.17E-02 O.OOE+OO 2.76E-03 0.OOE+00 B. Iodines
1. Total Iodine-131
2. Average Release Rate For Period Ci O.OOE 00 O.OOE 00 uCi/sec O.OOE+0O O.OOE+00 C. Particulates
1. Particulates (Half Life > 8 days)
2. Average Release Rate For Period Ci uCi/sec 1.63E-06 O.OOE+00 2.07E-07 O.OOE+00 3.78E-07 3.33E-07
3. Gross Alpha Radioactivity Ci D. Tritium
1. Total Release
2. Average Release Rate For Period Ci 1.OOE+0 I O.OOE+00 uCi/sec 1.27E+OO O.OOE+00 21

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # I ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.6-1 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES (Continued)

UNIT QTR#3 QTR#4 A. Fission and Activation Gases

1. Total Release
2. Average Release Rate For Period Ci 0.OOE+00 O.OOE+00 uCi/sec O.OOE+00 0.OOE+00 B. Iodines
1. Total Iodine-131 Ci O.OOE 00 O.OOE 00
2. Average Release Rate For Period uCi/sec O.OOE+00 O.OOE+00 C. Particulates
1. Particulates (Half Life > 8 days)
2. Average Release Rate For Period
3. Gross Alpha Radioactivity Ci uCi/sec Ci 8.98E-06 1.96E-06 1.14E-06 2.49E-07 6.27E-07 2.96E-07 D. Tritium
1. Total Release
2. Average Release Rate For Period Ci O.OOE+00 9.60E+00 uCi/sec O.OOE+00 1.22E+00 22

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.6-2 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES UNIT QTR#I QTR#2 A. Fission and Activation Gases

1. Total Release Ci 4.1 OE-0 I 1.38E+00 5.22E-02 1.75E-01
2. Average Release Rate For Period uCi/sec B. Iodines
1. Total Iodine-131
2. Average Release Rate For Period Ci O.OOE 00 1.72E-05 uCi/sec O.OOE+00 2.19E-06 C. Particulates
1. Particulates (Half Life > 8 days)
2. Average Release Rate For Period
3. Gross Alpha Radioactivity Ci uCi/sec Ci 2.91 E-06 3.54E-07 3.70E-07 4.50E-08 3.12E-07 7.16E-07 D. Tritium
1. Total Release Ci 2.43E-02 1.93E-01 3.09E-03 2.46E-02
2. Average Release Rate For Period uCi/sec 23

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.6-2 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES (Continued)

UNIT A. Fission and Activation Gases QTR#3 QTR#4 3.85E-01 2.30E-01

1. Total Release Ci
2. Average Release Rate For Period uCi/sec 4.89E-02 2.93E-02 B. lodines
1. Total Iodine-131
2. Average Release Rate For Period Ci 0.OOE 00 0.OOE 00 uCi/sec 0.OOE+00 O.OOE+00 C. Particulates
1. Particulates (Half Life > 8 days)
2. Average Release Rate For Period
3. Gross Alpha Radioactivity Ci uCi/sec Ci 1.03E-05 7.86E-07 1.31E-06 1.OOE-07 4.54E-07 6.29E-07 D. Tritium
1. Total Release Ci 1.63E-01 6.15E+00 2.07E-02 7.82E-01
2. Average Release Rate For Period uCi/sec 24

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 1 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.7-1 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Nuclides Released Continuous Mode QTR#1 QTR#2 Batch Mode QTR#1 QTR#2 Unit

1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-1 27 Xe-1 31m Xe-1 33m Xe-1 33 Xe-135m Xe-135 Xe-137 Xe-1 38 Total for Period Ci O.OOE+00 Ci O.OOE+0O Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci O.OOE+00 Ci 0.OOE+00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.OOE+00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 1.90E-02 O.OOE 00 2.69E-03 O.OOE 00 O.OOE 00 2.17E-02 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE+00
2. lodines 1-131 1-132 1-133 1-134 1-135 Total for Period Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE+00 Ci O.OOE 00 Ci O.OOE 00 Ci 0.00E+00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.OOE+00
3. Particulates (>8 Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 Days)

Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 25

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT# 1 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.7-1 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES (Continued)

Continuous Mode Nuclides Unit QTR#1 QTR#2 Released

3. Particulates ( > 8 Days) (continued)

Sr-89 Ci 1.63E-06 O.OOE 00 Sr-90 Ci O.OOE 00 O.OOE 00 Y-90 Ci O.OOE 00 O.OOE 00 Ru-1 03 Ci O.OOE 00 O.OOE 00 Ag-I 10 Ci O.OOE 00 O.OOE 00 Sn-113 Ci O.OOE 00 O.OOE 00 Sb-124 Ci O.OOE 00 O.OOE 00 Sb-125 Ci O.OOE 00 O.OOE 00 Te-129m Ci O.OOE 00 O.OOE 00 Cs-1 34 Ci O.OOE 00 O.OOE 00 Cs-136 Ci O.OOE 00 O.OOE 00 Cs-1 37 Ci O.OOE 00 0 OOE 00 Ba-140 Ci O.OOE 00 O.OOE 00 Ce-141 Ci O.OOE 00 O.OOE 00 Ce-144 Ci O.OOE 00 O.OOE 00 Total for Period Ci 1.63E-06 0.OOE+00

4. Particulates ( < 8 Days)

Mn-56 Ci O.OOE 00 O.OOE 00 Ni-65 Ci O.OOE 00 O.OOE 00 Br-82 Ci O.OOE 00 O.OOE 00 Rb-88 Ci O.OOE 00 O.OOE 00 Rb-89 Ci O.OOE 00 O.OOE 00 Sr-91 Ci O.OOE 00 O.OOE 00 Sr-92 Ci O.OOE 00 O.OOE 00 Y-92 Ci O.OOE 00 O.OOE 00 Zr-97 Ci O.OOE 00 O.OOE 00 Nb-97 Ci O.OOE 00 O.OOE 00 Tc-99m Ci O.OOE 00 O.OOE 00 Mo-99 Ci O.OOE 00 O.OOE 00 Sb-122 Ci O.OOE 00 O.OOE 00 Te-129 Ci O.OOE 00 O.OOE 00 Te-132 Ci O.OOE 00 O.OOE 00 Cs-138 Ci O.OOE 00 O.OOE 00 La-140 Ci O.OOE 00 O.OOE 00 Pr-144 Ci O.OOE 00 O.OOE 00 W-1 87 Ci O.OOE 00 O.OOE 00 Np-239 Ci O.OOE 00 O.OOE 00 Total for Period Ci 0.OOE+00 0.OOE+00 26

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT# 1 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.7-1 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES (Continued)

Nuclides Released Continuous Mode QTR#3 QTR#4 Batch Mode QTR#3 QTR#4 Unit

1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-1 27 Xe-1 31m Xe-1 33m Xe-133 Xe-1 35m Xe-1 35 Xe-1 37 Xe-1 38 Total for Period Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci 0.OOE+00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.OOE+00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.OOE+00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.OOE+00
2. lodines 1-131 1-132 1-133 1-134 1-135 Total for Period Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci 0.OOE+00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.OOE+00
3. Particulates (>

Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 Sr-89 Sr-90 8 Days)

Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.00E 00 8.98E-06 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.00E 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 4.83E-07 27

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 1 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.7-1 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES (Continued)

Continuous Mode Nuclides Unit QTR#3 QTR#4 Released

3. Particulates ( > 8 Days) (continued)

Y-90 Ru-103 Ag-110 Sn-113 Sb-124 Sb-125 Te-129m Cs-1 34 Cs-1 36 Cs-1 37 Ba-140 Ce-141 Ce-144 Total for Period

4. Particulates ( < 8 Days Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-1 29 Te-132 Cs-138 La-140 Pr-144 W-187 Np-239 Total for Period Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci 8.98E-06 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci O.OOE 00 Ci 0.OOE+00 4.83E-07 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 9.92E-07 O.OOE 00 O.OOE 00 O.OOE 00 1.96E-06 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.OOE+00 28

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.7-2 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Nuclides Released Continuous Mode QTR#1 QTR#2 Batch Mode QTR#1 QTR#2 Unit

1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-127 Xe-131m Xe-133m Xe-133 Xe-135m Xe-1 35 Xe-137 Xe-1 38 Total for Period Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.00E 00 Ci 0.00E 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE+00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.00E 00 8.52E-01 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 8.52E-01 2.67E-0 1 2.48E-04 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 1.27E-03 1.38E-01 0.OOE 00 3.72E-03 0.OOE 00 0.OOE 00 4.1 OE-01 3.41 E-0 I 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 1.15E-03 1.80E-01 0.OOE 00 5.83E-03 0.OOE 00 0.OOE 00 5.27E-01
2. lodines 1-131 1-132 1-133 1-134 1-135 Total for Period Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE+00 1.72E-05 0.OOE 00 8.37E-05 0.OOE 00 0.OOE 00 1.01 E-04
3. Particulates (>

Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 8 Days)

Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 29

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.7-2 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES (Continued)

Continuous Mode Nuclides Unit QTR#1 QTR#2 Released

3. Particulates ( > 8 Days) (continued)

Sr-89 Sr-90 Y-90 Ru-1 03 Ag-110 Sn-113 Sb-124 Sb-125 Te-129m Cs-134 Cs-136 Cs-137 Ba-140 Ce-141 Ce-144 Total for Period

4. Particulates (< 8 Days Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-1 29 Te-132 Cs-138 La-140 Pr-144 W-187 Np-239 Total for Period Ci 1.91E-06 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 1.00E-06 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 2.91 E-06 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE+00 0.OOE 00 1.77E-07 1.77E-07 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.00E 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 3.54E-07 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE+00 30

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.7-2 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES (Continued)

Nuclides Released Continuous Mode QTR#3 QTR#4 Batch Mode QTR#3 QTR#4 Unit

1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-1 27 Xe-131m Xe-1 33m Xe-1 33 Xe-1 35m Xe-135 Xe-137 Xe-138 Total for Period Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.00E 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.00E 00 Ci 0.00E+00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE+00 2.3 1E-01 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 1.48E-01 0.OOE 00 6.01E-03 0.OOE 00 0.OOE 00 3.85E-01 1.85E-01 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 4.52E-02 0.OOE 00 8.68E-05 0.OOE 00 0.OOE 00 2.30E-01
2. lodines 1-131 1-132 1-133 1-134 1-135 Total for Period Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE+00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE+00
3. Particulates (>

Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 8 Days)

Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 O.OOE 00 0.OOE 00 O.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 31

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.7-2 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES (Continued)

Continuous Mode Nuclides Unit QTR#3 QTR#4 Released

3. Particulates ( > 8 Days) (continued)

Sr-89 Sr-90 Y-90 Ru-1 03 Ag-110 Sn-113 Sb-124 Sb-125 Te-129m Cs-1 34 Cs-1 36 Cs-1 37 Ba-140 Ce-141 Ce-144 Total for Period

4. Particulates (< 8 Days Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-129 Te-132 Cs-138 La-140 Pr-144 W-187 Np-239 Total for Period Ci 1.03E-05 Ci 0.00E 00 Ci 0.00E 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.00E 00 Ci 0.OOE 00 Ci 1.03E-05 Ci 0.00E 00 Ci O.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci O.OOE 00 Ci 0.OOE 00 Ci 0.00E 00 Ci O.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE 00 Ci 0.OOE+00 0.OOE 00 3.93E-07 3.93E-07 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 7.86E-07 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.OOE 00 0.OOE 00 0.OOE 00 0.OOE 00 0.00E 00 0.00E 00 0.OOE 00 0.O0E+00 32

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 1 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.8-1 GASEOUS EFFLUENTS - DOSE SUMMATION AGE GROUP:

ADULT Bone Liver Thyroid Kidney Dose Pathway mrem mrem mrem mrem Inhalation 9.01 E-04 3.94E-04 3.94E-04 3.94E-04 Grass-Goat-Milk 9.48E-04 1.25E-04 1.24E-04 1.25E-04 Ground Plane O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Garden 8.15E-04 2.51 E-05 2.51 E-05 2.51 E-05 Meat 1.20E-04 2.58E-05 2.58E-05 2.58E-05 Total Dose 2.78E-03 5.70E-04 5.70E-04 5.70E-04 Lung GI-LLI Total Body Dose Pathway mrem mrem mrem Inhalation 4.82E-04 4.01 E-04 4.50E-04 Grass-Goat-Milk 1.24E-04 1.37E-04 3.56E-04 Ground Plane O.OOE+00 0.OOE+00 9.72E-07 Garden 2.51 E-05 4.57E-05 2.24E-04 Meat 2.58E-05 3.97E-05 5.51 E-05 Total Dose 6.57E-04 6.24E-04 1.09E-03 l(a) Sector: SE Range:

1.5 (b) Sector: WSW Range:

l 4.25 Noble Gases mrad Gamma Air Dose 6.02E-07 Beta Air Dose 1.35E-06 miles miles Sector: SE Range: 1.5 miles 33

FLORIDA POWER & LIGHT COMWANY ST. LUCIE UNIT # 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 TABLE 3.8-2 GASEOUS EFFLUENTS - DOSE SUMMATION AGE GROUP:

ADULT Bone Liver Thyroid Kidney Dose Pathway mrem mrem mrem mrem Inhalation 1.16E-06 1.31 E-04 1.40E-04 1.31 E-04 Grass-Goat-Milk 2.43E-06 4.22E-05 1.01 E-04 4.19E-05 Ground Plane O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Garden 1.66E-06 8.43E-06 2.20E-05 8.44E-06 Meat 2.36E-07 8.62E-06 1.03E-05 8.61 E-06 Total Dose 5.49E-06 1.91E-04 2.73E-04 1.90E-04 Lung GI-LLI Total Body Dose Pathway mrem mrem mrem Inhalation 1.32E-04 1.31 E-04 1.31 E-04 Grass-Goat-Milk 4.15E-05 4.16E-05 4.22E-05 Ground Plane O.OOE+00 O.OOE+00 2.15E-07 Garden 8.36E-06 8.50E-06 8.65E-06 Meat 8.59E-06 8.62E-06 8.64E-06 Total Dose 1.90E-04 1.90E-04 1.91 E-04

[(a) Sector: SE Range:

1.5 (b) Sector: WSW Range:

l 4.25 Noble Gases mrad Gamma Air Dose 5.08E-04 Beta Air Dose 2.64E-04 miles miles Sector: SE Range: 1.5 miles 34

FLORIDA POWER AND LIGHT COMPANY ST. LUCIE PLANT ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31,2003 UNITS i AND 2, TABLE 3.9 A.

Solid Waste Shipped Off-Site for Burial or Disposal

1. Type of Waste
a. Spent Resin, Process Filters
b. Dry Compressible Waste (Note 5)

Unit 12 Mo. Period M3 0

Ci 0

M3 4.35E+1 Ci 1.06E+0 Error %

NIA*

2.0 E+1

c. Irradiated M3 0

Components Ci 0

d. Other M3 0

Ci 0

2.Estimate of Major Nuclide Composition (By Waste Type)

Category Nuclides

a.

N/A NIA*

b.

Fe 55 4.21 E+1 Co 60 1.46E+1 Ni 63 1.39E+1 Cs 137 1.20E+1 Co 58 5.60E+0 Cs 134 2.48E+0 Mn 54 2.15E+0 H 3 1.72E+0 Ce 144 1.60E+0 C 14 1.22E+0 Cr 51 6.20E-1 Sb 125 5.40E-1 Zr 95 5.30E-1

c.

N/A N/A

d.

N/A*

N/A' NIA' N/A' 35

3. Solid Waste Disposition.

Number of Shipments 17 Mode of Transportation Sole Use Truck Destination Duratek, Oak Ridge, TN B.

Irradiated Fuel Shipments Number of Shipments 0

Mode of Transportation NIAL Destination N/A'

  • N/A = Not Applicable 36

At

  • I FLORIDA POWER AND LIGHT COMPANY ST. LUCIE PLANT ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 UNITS I AND 2, TABLE 3.9 (CONTINUED)

Waste Class Total Volume Total Curies Principal Type of Waste Category Type of Solidification Cubic Feet (Note 1)

Radionuclides (Note 3)

Reg. Guide Container Agent

(_ Notes i and 2) 1.21 (Note 4)_

Class A 1536.96 1.06Ei0 NIA PWR 1.b.

Non-None Compressible Specification Waste (note 5)

Strong Tight Package w

FLORIDA POWER AND LIGHT COMPANY ST. LUCIE PLANT ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31 2003 UNITS I AND 2, TABLE 3.9 (CONTINUED)

SOLID WASTE SUPPLEMENT NOTE 1:

The total radionuclide activity and composition of solid waste shipped from the St. Lucie Plant, Units I and 2 are determined using a combination of qualitative techniques. In general, the St. Lucie Plant follows the guidelines outlined in the Low Level Waste Branch Technical Position (BTP) on Radioactive Waste Classification (5111/83) for these determinations. The most frequently used techniques for determining the total activity in a package are the "Dose-to-Curie" method and "Concentration Times Volume or Mass' calculations. Where appropriate. engineering type activation analyses may be applied. Since each of the above methodologies Involve, to some extent, qualitative parameters, the total activity Is considered to be an estimate.

The composition of radionuclides in the waste is determined by both on-site analyses for principal gamma emitters and periodic off-site analyses for other radionuclides. The on-site analyses are performed either on a batch basis or on a routine basis using reasonably representative samples as appropriate for the waste type. Off-site analyses are used to establish scaling factors or other estimates for radionuclides such as H3, C14, Fe55; Sr90, Tc99, 1129, Pu238, Pu239/240, Pu241, Am241, Cm242 and Cm243/244.

NOTE 2:

"Principal Radionuclides' refer to those radionuclides contained in the waste in concentrations greater than 0.01 times the concentration of nuclides listed in Table 1 or 0.01 times the smallest concentration of nuclides listed In Table 2 of 10 CFR 61.

NOTE 3:

'Type of Waste" is generally specified as described in NUREG 0782, Draft Environmental Impact Statement on 10 CFR 61. 'Licensing Requirements for Land Disposal of Radioactive Waste".

NOTE 4:

'Type of Container' refers to the transport package.

NOTE 5:

The volume and activity listed for "Dry Compressible Waste' represent the quantity of material that during the reporting period was sent to the licensed disposal facilities. Some of this material was shipped to a contract vendor for volume reduction or recycle prior to final disposal at the licensed disposal facilities. During the reporting period, seventeen (17) shipments of dry active waste, non-compressible waste, and resins (27,971 cubic feet, 1.05E+0 curies) were made from the St. Lucie Plant to the volume reduction facility. These materials were shipped via "Sole Use Truck' in non-specification, strong tight containers.

38

FLORIDA POWER & LIGHT COMPANY ST. LUCE UNIT # I & 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 ATTACHMENT - A (Page 1 of 2)

Unplanned Release of Unit 2 Gas Decay Tank 2C Description of the event:

On 6/12/03 prior to criticality, the Unit 2 waste gas system was realigned from the plant stack to the 2C gas decay tank (GDT) utilizing the 2B gas compressor and the gas surge tank (GST). During the time the system was aligned to the 2C GDT, the tank pressure dropped 23 psig. This constitutes an unplanned release per C-200 ODCM (Offsite Dose Calculation Manual).

Apparent Cause After placing the waste gas system in service, the on-shift unlicensed operator observed that the GST pressure had increased (exact value not known) and the "C" GDT pressure dropped with the "B" gas compressor in service. He notified the control room that the waste gas system was realigned back to the plant stack. Chemistry was notified of this system re-alignment. The drop in GDT gas pressure was due to the "2B" waste gas compressor was not working properly after return to service following maintenance and the auto gas analyzer was lined up to take a sample from the "C" GDT per Operating Procedure 2-0530020 "Waste Gas System Operation." The gas was directed back to the GST from the in service "C" GDT. While the auto gas analyzer was in service, the in service GDT provided a continuous sample flow being removed from it.

The GST design pressure is 40 psig. The GST relief valve V6778 setpoint is 20 psig per TEDB. Based on calculating the tank volumes, the pressure got high enough to open relief valve V6778 which goes to the relief valve collection header. Once the waste gas system was realigned to the plant stack, the gas in the gas surge tank and the vent gas collection

'header was discharged to the plant stack. This constitutes an unplanned, but monitored release. No plant or site radioactive release limits were exceeded during this event.

Corrective Actions

1. The waste gas system operating procedure was revised to add steps to vent the waste gas compressor head oiling system prior to placing a waste gas compressor in service following maintenance. Additional guidance was added to enhance awareness of the waste gas system operation during re-alignment activities to prevent possible unplanned releases.
2. The waste gas system surveillance procedures were revised to ensure operators drain the waste gas compressor accumulators weekly.

39

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNIT # 1 & 2 ANNUAL REPORT JANUARY 1, 2003 THROUGH DECEMBER 31, 2003 ATTACHMENT - A (Page 2 of 2)

Consequences of the unplanned release:

Gas Decay Tank 2C UNPLANNED RELEASE DATA I

Nuclide Sample Release Symbol uCi/cc Curies Ar-41 0.OOE+00 0.00E+00 Kr-85m 0.00E+00 0.OOE+00 Kr-87 0.OOE+00 0.OOE+00 Kr-88 0.OOE+00 0.OOE+00 Xe-133m 1.81 E-04 3.29E-03 Xe-133 5.16E-04 1.16E-03 Xe-1 35m 0.OOE+00 0.00E+00 Xe-1 35 6.69E-04 4.27E-03 Xe-1 37 0.OOE+00 0.00E+00 Xe-1 38 0.00E+00 0.OOE+00 Gas Total 1.37E-03 8.72E-03 Release Start Date 6/12/2003 Release End Date 6/12/2003 Release Minutes 6.00E+01 minutes Release Volume 6.38E+06 cc.s Total Body Dose Rate 3.99E-03 mRem/yr Total Body Dose Rate 2.80E-03 percent site limit Skin Dose Rate 9.25E-03 mRem/yr Skin Dose Rate 1.08E-03 percent site limit Release Rate 3.76E+00 ft3/minute Gamma Air Dose 4.94E-07 mrad Gamma Air Dose 1.OOE-05 percent annual limit Beta Air Dose 7.95E-07 mrad Beta Air Dose 1.OOE-05 percent annual limit Tritium I 1.OOE-06 I 6.38E-06 I dose contribution was negligible Particulates - None detected in Gas Decay Tank 2C lodines - None detected in Gas Decay Tank 2C No Site Release Rate, Quarterly, or Annual Dose Limit(s) were exceeded.

40