MONTHYEARL-24-009, HDI Annual Occupational Radiation Exposure Data Reports - 20232024-04-29029 April 2024 HDI Annual Occupational Radiation Exposure Data Reports - 2023 L-24-010, Request for Preapplication Readiness Assessment of the Draft License Termination Plan2024-04-22022 April 2024 Request for Preapplication Readiness Assessment of the Draft License Termination Plan L-24-008, Reply to a Notice of Violation EA-2024-0232024-03-29029 March 2024 Reply to a Notice of Violation EA-2024-023 L-24-007, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations – Holtec Decommissioning International, LLC (HDI)2024-03-29029 March 2024 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations – Holtec Decommissioning International, LLC (HDI) L-24-002, Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G2024-02-0202 February 2024 Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G L-23-019, Proof of Financial Protection 10 CFR 140.152023-12-18018 December 2023 Proof of Financial Protection 10 CFR 140.15 L-23-012, Master Decommissioning Trust Agreement Changes for Indian Point Nuclear Generating Units 1, 2 and 3, Pilgrim Nuclear Power Station, Palisades Nuclear Plant and the Non-Qualified Trust for Big Rock Point2023-11-13013 November 2023 Master Decommissioning Trust Agreement Changes for Indian Point Nuclear Generating Units 1, 2 and 3, Pilgrim Nuclear Power Station, Palisades Nuclear Plant and the Non-Qualified Trust for Big Rock Point L-23-004, HDI Annual Occupational Radiation Exposure Data Reports - 20222023-04-24024 April 2023 HDI Annual Occupational Radiation Exposure Data Reports - 2022 L-23-003, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2023-03-31031 March 2023 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations L-22-042, Oyster, Pilgrim, Indian Point, Palisades and Big Rock Point - Proof of Financial Protection 10 CFR 140.152022-12-14014 December 2022 Oyster, Pilgrim, Indian Point, Palisades and Big Rock Point - Proof of Financial Protection 10 CFR 140.15 L-22-041, Supplemental Information to Enhance Exemption Request Detail for Pilgrim ISFSI Annual Radioactive Effluent Release Report Due Date Extension2022-12-0909 December 2022 Supplemental Information to Enhance Exemption Request Detail for Pilgrim ISFSI Annual Radioactive Effluent Release Report Due Date Extension L-22-036, Decommissioning Trust Fund Agreement2022-11-0808 November 2022 Decommissioning Trust Fund Agreement L-22-026, Occupational Radiation Exposure Data Report - 20212022-04-29029 April 2022 Occupational Radiation Exposure Data Report - 2021 L-22-022, And Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations - Holtec.2022-03-25025 March 2022 And Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations - Holtec. L-21-134, And Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Independent Spent Fuel Storage Installations2021-12-17017 December 2021 And Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Independent Spent Fuel Storage Installations L-21-114, Registration of Casks to Store Spent Fuel2021-11-0404 November 2021 Registration of Casks to Store Spent Fuel L-21-098, Response to Request for Additional Information (RAI) - License Amendment Request to Approve the Pilgrim Nuclear Power Station Independent Fuel Storage Installation Only Emergency Plan2021-09-0707 September 2021 Response to Request for Additional Information (RAI) - License Amendment Request to Approve the Pilgrim Nuclear Power Station Independent Fuel Storage Installation Only Emergency Plan L-21-073, Decommissioning International - Fuel Storage Cask Certificate Number: 1014 - Registration of Changes to Previously Loaded Casks2021-08-0404 August 2021 Decommissioning International - Fuel Storage Cask Certificate Number: 1014 - Registration of Changes to Previously Loaded Casks L-21-086, Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G2021-07-22022 July 2021 Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G L-21-078, Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G2021-07-0606 July 2021 Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G L-21-072, Supplemental Information to Support Proposed Independent Spent Fuel Storage Installation- Only Security, Training, and Qualification, Safeguards Contingency Plan2021-06-22022 June 2021 Supplemental Information to Support Proposed Independent Spent Fuel Storage Installation- Only Security, Training, and Qualification, Safeguards Contingency Plan L-21-057, Supplemental Information to Update - License Amendment Request to Approve the Pilgrim Nuclear Power Station Independent Fuel Storage Installation Only Emergency Plan2021-05-20020 May 2021 Supplemental Information to Update - License Amendment Request to Approve the Pilgrim Nuclear Power Station Independent Fuel Storage Installation Only Emergency Plan L-21-048, Annual Report of Individual Monitoring of Radiation Exposure for CY20202021-04-27027 April 2021 Annual Report of Individual Monitoring of Radiation Exposure for CY2020 L-21-038, Onsite Property Damage Insurance (10 CFR 50.54(w)(3))2021-04-0101 April 2021 Onsite Property Damage Insurance (10 CFR 50.54(w)(3)) L-21-037, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2021-03-31031 March 2021 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations L-21-036, Proposed Independent Spent Fuel Storage Installation-Only Security, Training and Qualification, Safeguards Contingency Plan2021-03-17017 March 2021 Proposed Independent Spent Fuel Storage Installation-Only Security, Training and Qualification, Safeguards Contingency Plan L-21-008, License Amendment Request to Approve Pilgrim Nuclear Power Station Independent Spent Fuel Storage Installation Only Emergency Plan2021-02-18018 February 2021 License Amendment Request to Approve Pilgrim Nuclear Power Station Independent Spent Fuel Storage Installation Only Emergency Plan L-20-080, Request for a One-Time Exemption from 10 CFR 73, Appendix B, Section VI, Subsection C.3.(I)(1) Regarding Annual Force-on-Force (FOF) Exercises, Due to Covid 19 Pandemic2020-11-20020 November 2020 Request for a One-Time Exemption from 10 CFR 73, Appendix B, Section VI, Subsection C.3.(I)(1) Regarding Annual Force-on-Force (FOF) Exercises, Due to Covid 19 Pandemic L-20-057, Registration of Use of Cask to Store Spent Fuel2020-08-17017 August 2020 Registration of Use of Cask to Store Spent Fuel L-20-048, Physical Security, Training & Qualification and Safeguards Contingency Plan, Revision 192020-07-21021 July 2020 Physical Security, Training & Qualification and Safeguards Contingency Plan, Revision 19 L-20-029, Response to NRC Request for Clarifying Information2020-04-22022 April 2020 Response to NRC Request for Clarifying Information L-20-022, Nuclear Onsite Property Damage Insurance (10 CFR 50.54(w)(3))2020-04-0101 April 2020 Nuclear Onsite Property Damage Insurance (10 CFR 50.54(w)(3)) L-20-023, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2020-03-31031 March 2020 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations L-20-017, Annual Report of Individual Monitoring of Radiation Exposure for 20192020-02-27027 February 2020 Annual Report of Individual Monitoring of Radiation Exposure for 2019 L-19-021, Decommissioning International (HDI) Response to Confirmatory Order EA-17-132/EA-17-1532019-12-31031 December 2019 Decommissioning International (HDI) Response to Confirmatory Order EA-17-132/EA-17-153 L-19-020, 10 CFR 140.15 Proof of Financial Protection2019-12-27027 December 2019 10 CFR 140.15 Proof of Financial Protection L-19-003, (PNPS) - Transmittal of Revision to 10 CFR 50.54(q) Review for EP-PP-01, PNPS Emergency Plan Revision 512019-10-16016 October 2019 (PNPS) - Transmittal of Revision to 10 CFR 50.54(q) Review for EP-PP-01, PNPS Emergency Plan Revision 51 L-2018-064, Submittal of Joint Composite Adversary Force2018-03-0808 March 2018 Submittal of Joint Composite Adversary Force L-06-002, Correction to Response to Generic Letter 2006-02, Grid Reliability and the Impact on Plant Risk and the Operability of Offsite Power2008-07-24024 July 2008 Correction to Response to Generic Letter 2006-02, Grid Reliability and the Impact on Plant Risk and the Operability of Offsite Power 2024-04-29
[Table view] |
Text
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 HDI-PIL-19-021 Page 1 of 2 EA-17-132/153 December 31, 2019 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Pilgrim Nuclear Power Station Renewed Facility Operating License No. DPR-35 NRC Docket No. 50-293
Subject:
Holtec Decommissioning International (HDI) Response to Confirmatory Order EA-17-132/EA-17-153
References:
[1]
Entergy Operations, Inc./Entergy Nuclear Operations Inc. (Entergy) letter to U. S. Nuclear Regulatory Commission (NRC), Entergy Response to Confirmatory Order EA-17-132/EA-17-153, Element K - 2019 Summary, dated December 30, 2019
[2]
Entergy Operations, Inc./Entergy Nuclear Operations Inc. (Entergy) letter to U. S. Nuclear Regulatory Commission (NRC), Entergy Response to Confirmatory Order EA-17-132/EA-17-153, dated March 21, 2019 (ADAMS Accession No. ML19081A270)
In a letter dated December 30, 2019 (Reference 1), Entergy Operations, Inc./Entergy Nuclear Operations Inc. (Entergy) provided the 2019 Summary of actions taken to address Confirmatory Order EA-17-132/EA-17-153. Holtec Decommissioning International, LLC (HDI) is providing additional information for the Pilgrim Nuclear Power Station (PNPS).
A review identified that the scheduled completion dates for the two actions stated in Reference 2 needed to be changed. HDI became aware of a gap in addressing the communication action on December 5, 2019. A revision of commitments is provided in Enclosure 1 to this letter. The revision provides 90 days from the date of notification for the communication to be documented.
A time frame comparable to Entergys response in Reference 2 was selected for the survey of integrity messaging. HDI understands the importance of addressing acts of willful misconduct and the need for integrity among the workforce. HDI will continue to coordinate with Entergy to ensure the future actions outlined in the Order are met.
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 HDI-PIL-19-021 Page 2 of 2 Should you have any questions or require further information, please contact me at (856) 797-0900, x3813.
Respectfully, Andrea Sterdis HDI VP Regulatory and Environmental Affairs Holtec Decommissioning International, LLC : List of Regulatory Commitments cc:
NRC Region I Regional Administrator NRC NRR Project Manager (Pilgrim Nuclear Power Station)
NRC NMSS Project Manager (Pilgrim Nuclear Power Station)
List of Regulatory Commitments
LIST OF REGULATORY COMMITMENTS The following table identifies those actions committed to by HDI in this document. Any other statements in this submittal are provided for information purposes and are not considered to be regulatory commitments.
Commitment One-Time Action Scheduled Completion Date HDI will utilize the Entergy Tier 2 Communication process to ensure that the one remaining semiannual integrity communication is delivered in a timely manner. HDI will record the receipt and acknowledgement of these communications for future traceability.
X March 4, 2020 Element D of the Confirmatory Order requires Entergy to identify specific criteria necessary to perform annual effectiveness reviews. HDI will conduct a survey to ensure the integrity message has been received and understood. HDI will modify its corrective actions, as needed, based on the results of the effectiveness reviews.