FirstEnergy Nuclear Operating Company Eric A. Larson Site Vice President April 23, 2013 L-13-058 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit No.2 Docket No. 50-412, License No. NPF-73 Steam Generator Inspection Report - Technical Specification 5.6.6.2.1 Beaver Valley Power Station P.O. Box 4 Shippingport, PA 15077 724-682-5234 Fax: 724-643-8069 In accordance with Technical Specification 5.6.6.2.1, FirstEnergy Nuclear Operating Company (FENOC) hereby submits a report of steam generator inspections performed during the Beaver Valley Power Station, Unit No.2 fall 2012 refueling outage (2R16).

During 2R16 a teleconference was held with NRC staff to discuss the progress of, and provide preliminary information regarding, steam generator inspection activities of the refueling outage (Accession Nos. ML12310A066 and ML12289A117). The enclosed report provides the required final information regarding the inspections, including tabulations of steam generator examination results for tubes in the A, B, and C steam generators.

There are no regulatory commitments contained in this letter. If there are any questions, or if additional information is required, please contact Mr. Thomas A. Lentz, Manager - Fleet Licensing, at (330) 315-6810.

Eric A. Larson

Beaver Valley Power Station, Unit No.2 L-13-058 Page 2

Enclosure:

Unit #2 - 2R16 Steam Generator 180 Day Report cc:

NRC Region I Administrator NRC Resident Inspector NRC Project Manager Director BRP/DEP Site BRP/DEP Representative

Enclosure L-13-058 Unit #2 - 2R16 Steam Generator 180 Day Report (75 Pages Follow)

FIRST ENERGY NUCLEAR OPERATING COMPANY Technical Services Engineering Department Nuclear Engineering Programs Section Unit #2 - 2R16 Steam Generator 180 Day Report Prepared by:

..::::G=a~A=lb=e=rti--",--..:..-,~:JS_:;_~


:0

~=-_C(..::.....::..._-

Date: Oct\\@G,lI'3 Reviewed by:

Approved by:

Steam Generator Owner Carl BaUlstone &~

Supervisor, Nuclear Programs Pat Pauvlinch wf~

Manager, Technical Services Date:

z./~/t3 Date: #

Information Required by Technical Specification 5.6.6.2.1 Technical Specification (TS) 5.6.6.2.1 requires reporting of the following information after completion of an inspection performed in accordance with the Specification 5.5.5.2, Unit 2 Steam Generator (SG) Program. Information required by TS 5.6.6.2.1.a through TS 5.6.6.2.1.i is provided below for activities performed during the fall 2012 refueling outage (2R16).

Refer to the Definitions of Abbreviations, Codes and Reporting Terminology section of this report for abbreviations, codes and other terms used throughout this report.

a) The scope of inspections performed on each SG:

Primary Side:

Bobbin Coil Probe 100% of the inservice tubes, full length (except Row 1 and 2 U-bends) per Generic Letter (GL) 95-05, "Voltage-Based Repair Criteria for Westinghouse Steam Generator Tubes Affected by Outside Diameter Stress Corrosion Cracking," dated August 3, 1995 Plus Point Probe 100% of Row 1 and 2 U-bends 100% of the hot leg TTS from 6 inches above to 3 inches below the TTS NOTE 1 100% of TSP DSI/DNI indications 100% of TSP mix residual signals ~ 55 0 and ~ 1.25 volts 100% of TSP mix residual signals> 1.5 volts 100% of dented hot and cold leg TSP's ~ 5.0 volts 100% of dents ~ 2.0 but < 5.0 volts at the 1st, 2nd, 3rd and 4th hot leg TSP's 100% of dents located at AVB intersections (+/- 1 inch of AVB centerline) 100% of frees pan dings ~ 1 volt 100% of BLG and OXP signals in the hot leg tubesheet below the F* distance but above the tubesheet neutral axis 100% of bobbin "I-codes", such as freespan differential signals meeting the change criteria (Phase rotation: > 10 0 and/or Voltage amplitude: > 0.5 volts) 100% of freespan signals not resolved as MBMs or without a historical review 100% of newly installed Westinghouse Alloy 800 sleeves 25% of Row 3 through 8 U-bends 20% of the cold leg TTS from 6 inches above to 3 inches below the TTS (SG C only) NOTE 1 Visual Examinations Divider Plate Welds (hot and cold leg) per Westinghouse NSAL 12-1 There are 9 hot leg and 9 cold leg tube locations (SG A - 4; SG B-2; SG C - 3) which contain Alloy 600 plugs repaired with the Westinghouse Plug-in-Plug (PIP) technique. These locations are visually examined each outage to assess the condition of the tack weld which holds the PIP in place. No anomalous conditions were reported.

NOTE 1 - For those tube locations where the expansion transition is located deeper into the tubesheet, the inspection distance into the tubesheet was adjusted to 5 inches below the top of the tubesheet.

Page 2 of 9

100% of tube plugs (as-found and as-left condition). As part of the routine steam generator inspection process, a visual examination is performed each time the primary side is opened to document the condition of the hot and cold leg channelheads. This process also includes tube plug accountability. Ouring 2R16, as well as in all prior outages, the examinations verified that the correct number of tube plugs were present and in the proper tube locations. No anomalies were reported.

Secondary Side:

A visual inspection of the secondary side tubesheet face, annulus and tube lane was performed during 2R16 in all 3 steam generators. Foreign object search and retrieval (FOSAR) was also performed. The following table contains the results of the FOSAR effort and lists (a) a description of the foreign material observed in each steam generator, (b) the location of the foreign material, and (c) whether the foreign material was retrieved or left in the steam generator.

SG Description Location Retrieved A

Gasket Material TSC Yes A

Small Wire TSH No B

Sludge Rock TSH Yes C

Sludge Rock TSC Yes C

Small Wire TSH Yes C

Sludge Rock TSC Yes C

Sludge Rock TSC No Foreign material that was not removed from the secondary side of the steam generators was evaluated and documented in Westinghouse Letter FENOC-12-124, 'Transmittal of Evaluation of Foreign Objects - 2R16 Steam Generator Secondary Side Services". Based on this evaluation, the foreign material that remained in the secondary side of the steam generator was determined to be acceptable for continued operation (i.e., tube integrity would be maintained for at least two more operating cycles). Sludge rocks are not judged to be foreign material since they are considered to be indigenous to the SG.

For those tube locations where potential loose part indications were reported during the 2R 16 eddy current examinations (e.g., bobbin coil or Plus Point probes) and no visual inspection was performed at those particular tube locations, the Plus Point probe was used to verify that no degradation or tube wall wear was present. These tubes remained in service.

SG A Feedwater Header - Ultrasonic thickness measurements and a visual inspection from the inside of the feedwater header were performed on the patch plate that was installed during 2R 13. This patch plate was welded over an area of the header where a through wall hole was reported in 2R13. The 2R16 thickness measurements were found to be acceptable and the visual inspection found no areas of the plate being eroded. A visual inspection of the SG A steam drum region was also performed. No anomalies were reported.

b) Active2 degradation mechanisms found:

The following existing degradation mechanisms were reported during 2R 16:

Axial OOSCC within the hot leg sludge pile region Axial OOSCC at the hot leg TTS expansion transition region Circumferential OOSCC at the hot leg TTS expansion transition region Circumferential PWSCC at the hot leg TTS expansion transition region (SG A only)

Axial OOSCC at non-dented TSP intersections Page 3 of 9

Axial OOSCC at.:s 5 volt freespan dings (SG A only)

Wear at AVB locations Wear due to foreign object interaction c) Nondestructive examination techniques utilized for each degradation mechanism:

For the degradation mechanisms observed during 2R 16, bobbin coil probes were used as the primary method of detection except at or below TTS and in Row 1 and 2 U-bends where bobbin probes are not qualified. In these areas, Plus Point probes were employed. Plus Point probes were also used to re-examine any ambiguous bobbin coil signals that were reported.

The 2R16 examination techniques were qualified, for detection and sizing (as applicable) of the existing and potential degradation mechanisms listed in the 2R16 degradation assessment, in accordance with Appendices H and I of the EPRI, "Steam Generator Management Program:

Pressurized Water Reactor Steam Generator Examination Guidelines: Revision 7."

2R16 Examination Techniques Used for Degradation Detection/Sizing Degradation Mode Tube Location Probe EPRI ETSS*

AxialOOSCC H/L sludge pile, expansion transitions Bobbin 128413 3 Coil Plus Point 128424 Circumferential OOSCC H/L expansion transitions 3 Coil Plus Point 21410.1 Circumferential PWSCC 20510.1 Non-dented & dented H/L TSP's Bobbin 128411 AxialOOSCC (Bobbin < 5 volts, Plus Point.::: 5 volts) 3 Coil Plus Point 22401.1 128424 AxialOOSCC Freespan dings < 5 volts Bobbin 24013.1 3 Coil Plus Point 22401.1 Volumetric Top of tubesheet 3 Coil Plus Point 21998.1 Bobbin 96004.3 Wear AVB locations 1 Coil Plus Point 21998.1

  • - The applicable EPRI Examination Technique Specification Sheet (ETSS) is listed for reference only.

Site-specific ETSS's are developed prior to each steam generator inspection for each existing and potential degradation mechanism identified in the 2R 16 degradation assessment. The site-specific ETSS's are developed in accordance with Appendices H and I of the EPRI, "Steam Generator Management Program: Pressurized Water Reactor Steam Generator Examination Guidelines: Revision 7."

The examination techniques utilized during 2R16 are considered "Site Validated" as defined in the EPRI, "Steam Generator Management Program: Pressurized Water Reactor Steam Generator Examination Guidelines: Revision 7," for each existing and potential degradation mechanism listed in the 2R16 degradation assessment.

NOTE 2 - Per the EPRI, "Steam Generator Management Program: Steam Generator Integrity Assessment Guidelines," Revision 3, the word "existing" is now used in lieu of the word "active" when describing degradation that has been previously and/or currently observed in the steam generators.

Page 4 of 9

d) Location, orientation (if linear), and measured sizes (if available) of service induced indications:

The 2R 16 Steam Generator Examination Results section of this report lists information that includes the location, orientation and measured sizes of service-induced indications. Further explanation of the information provided in these tables is given below:

1)

Bobbin probe indications reported as "I-codes" (i.e., ONI, OSI, OTI or NQI) were re-inspected with the Plus Point probe.

2)

Bobbin probe indications reported as PSI were re-inspected with the Plus Point probe. If the Plus Point probe indicated a possible TSP ligament breach existed (CSI), it was further evaluated by the OEM engineering group. All ligament breach extents were found to be acceptable for continued plant operation.

3)

New AVB indications reported from the bobbin probe listed as PCT were inspected with the Plus Point probe. If the Plus Point probe indicated no crack-like flaws were present within the wear scar, a wear call (WAR) was assigned to the Plus Point report.

4)

Plus Point indications reported as "I-codes" (i.e., SAl, SCI, MAl or MCI) were either (a) removed from service via plugging, (b) repaired by sleeving if the indications were located within the sleeving boundary at the top of the hot leg tubesheet or (c) left in service if the indications qualified under the requirements of GL 95-05.

5)

All hot leg top of tubesheet circumferential indications not sleeved were stabilized prior to plug installation.

e) Number of tubes plugged or repaired during the inspection outage for each active degradation mechanism:

The following tables list the number of tubes plugged or repaired for each existing degradation mechanism found during 2R16. Westinghouse Alloy 800 "leak limiting" sleeves were installed for degradation reported at or near the hot leg top of tubesheet. The alternate repair criteria of GL 95-05 was also implemented in this outage.

For the following Tables:

The Hot Leg Sludge Pile column includes indications located above the top-of-tubesheet.

The Hot Leg Expansion Transition (Exp Trans) column includes indications located (a) at the secondary side face of the tubesheet, (b) at the expansion transition or (c) within the tubesheet.

2RCS-SG21A Degradation Hot Leg Hot Leg Hot Leg Free Span Total Mode Sludge Pile Exp Trans TSP Ding Indications AxialOOSCC 1

4 7

1 13 Circ OOSCC 50 50 Circ PWSCC 1

1 Total 1

55 7

1 64 Notes for 2RCS-SG21A (64 indications in 62 tubes):

1) One tube was sleeved due to a eirc PWSCC indication at the hot leg tubesheet and also contained an axial OOSCC indication at a TSP which remained inservice under GL 95-05.
2) One tube was sleeved due to an axial and eirc OOSCC indication at the hot leg tubesheet.
3)

Fifty-three tubes were sleeved for indications located at the hot leg tubesheet.

4) Six tubes exhibited axial OOSCC indications at TSP's and remained inservice under GL 95-05.
5)

One tube was plugged for a free span ding with axial OOSCC indication.

Page 5 of 9

2RCS-SG21B Degradation Hot Leg Hot Leg Hot Leg Free Span Total Mode Sludge Pile Exp Trans TSP Ding Indications AxialOOSCC 1

2 15 18 Circ.OOSCC 21 21 Total 1

23 15 39 Notes for 2RCS-SG21 B: (39 indications in 39 tubes)

1) Twenty three tubes were sleeved for indications located at the hot leg tubesheet. Three tubes were subsequently plugged due to sleeve installation anomalies.
2) Fifteen tubes exhibited axial ODSCC indications at TSP's and remained inservice under GL 95-05.
3) One tube was plugged for being located outside of the sleeving boundary.

2RCS-SG21C Degradation Hot Leg Hot Leg Hot Leg Free Span Total Mode Sludge Pile Exp Trans TSP Ding Indications AxialOOSCC 15 15 Circ OOSCC 27 27 Total 27 15 42 Notes for 2RCS-SG21C (42 indications in 42 tubes):

1) Twenty three tubes were sleeved for indications located at the hot leg tubesheet. One tube was subsequently plugged due to sleeve installation anomalies.
2) Fifteen tubes exhibited axial ODSCC indications at TSP's and remained inservice under GL 95-05.
3) Four tubes were plugged for being located outside of the sleeving boundary.

f) Total number and percentage of tubes plugged or repaired to date:

The total number of tubes plugged as of the end of 2R 16 is 733 tubes (7.24%). The equivalent plugging level due to the installation of the Alloy 800 sleeves is 737 tubes (7.28%).

g) The results of condition monitoring, including the results of tube pulls and in-situ testing:

During the 2R 16 steam generator tube inspections, no indications were observed that exceeded the structural integrity limits for either axial or circumferential degradation (burst integrity greater than 3 times normal operating primary to secondary pressure differential). Therefore, no tubes contained indications that could potentially challenge the tube integrity recommendations of NEI 97-06, Revision 3, "Steam Generator Program Guidelines." The relative severity levels of the degradation observed during 2R16 were judged to be consistent with or bounded by the levels associated with the 2R07 through 2R 15 inspection results.

Based on the indications observed during 2R 16, the steam generator tubing is expected to meet all operational structural and leakage integrity requirements at End-Of-Cycle 17. None of the indications reported during 2R 16 represented a leakage potential at postulated main steam line break conditions.

The tube pull required under GL 95-05 was deferred until 2R 17. Based on the degradation observed during 2R16, no additional tube pulls were required.

No In-Situ pressure testing was required.

Page 6 of 9

h) The effective plugging percentage for a" plugging and tube repairs in each SG:

The following table lists the plugging percentages and the effective plugging percentage due to sleeving for each steam generator as of the end of 2R 16.

SG Tubes Plugged Total Tubes Sleeves Plug Effective 2R16 Plugged Plugged Insta"ed Equivalency Plugging %

2RCS-SG21A 1

260 7.70%

55 262 7.76%

2RCS-SG21B 4

266 7.78%

20 267 7.91%

2RCS-SG21C 5

207 6.13%

22 208 6.16%

TOTAL 10 733 7.24%

97 737 7.28%

i) Repair method utilized and the number of tubes repaired by each repair method:

Westinghouse Alloy 800 "leak limiting" sleeves were installed for degradation observed at the hot leg top of tubesheet. A total of 101 sleeves were installed in 101 tubes but four tubes were removed from service due to sleeve installation anomalies which left 97 sleeves (97 tubes) inservice for Cycle 17.

SG Sleeves Sleeves Sleeves Insta"ed Plugged Inservice 2RCS-SG21A 55 0

55 2RCS-SG21B 23 3

20 2RCS-SG21C 23 1

22 TOTAL 101 4

97 Page 7 of 9

Definitions of Abbreviations, Codes, and Reporting Terminology 3 Letter Code Definitions Term Bobbin Coil Probe BLG Bulge DNI Dent/Ding with a Possible Indication DSI Distorted Tube Support Plate Signal with Possible Indication DTI Distorted Tubesheet Signal with Possible Indication MBM Manufacturing Burnish Mark NQI Non-Quantifiable Indication OXP Over Expansion PCT Percent Through Wall PSI Possible Tube Support Plate Indication (Ligament Breach)

Term Plus Point Probe CSI Confirmed Tube Support Plate Indication (Ligament Breach)

MAl Multiple Axial Indications MCI Multiple Circumferential Indications SAl Single Axial Indication SCI Single Circumferential Indication VOL Volumetric Indication WAR Wear Additional Definitions Term Definition AVB Anti-Vibration Bar DENT Observed within a Tube Support Plate DING Observed in Free-Span Region of the Tubing EPRI Electric Power Research Institute H/L Hot Leg (Inlet)

NSAL Nuclear Safety Advisory Letter ODSCC Outside Diameter Stress Corrosion Cracking PLP Possible Loose Part PWR Pressurized Water Reactor PWSCC Primary Water Stress Corrosion Cracking TSP Tube Support Plate TTS Top of Tubesheet Page 8 of 9

2R16 Steam Generator Examination Results Attachments A, B, and C provide steam generator examination results for tubes in the Beaver Valley Power Station, Unit No.2, Steam Generator A (2RCS-SG21A), Steam Generator B (2RCS-SG21 B), and Steam Generator C (2RCS-SG21 C) with service-induced indications.

The data contained in the Attachments comes from the production analysis process and has not been re-sized or re-profiled for structural integrity concerns (i.e. field reported call).

Therefore, variations in the dimensions of a given indication (e.g. length, angular extent, voltage, etc.) may exist between this document and those documents previously submitted to the NRC in support of the fall 2012 outage (2R16).

Refer to the following tables for a description of terms used in these attachments.

Description of Column Headings and Data Abbreviations Used in Steam Generator Examination Results Report Header Definitions Term Definition ROW/COL Row & column of tube location INO Type of indication LOC Location of nearest support structure INCH Indication distance from nearest support structure

%TW Field measured percent through wall of an indication LENGTH Field measured length of an indication ANGLE Field measured angular extent of an indication around the tube VOLTS Field measured voltage amplitude of an indication PHASE Field measured angular rotation of an indication CHAN Recording channel of an indication FROM Starting point of examination TO End point of examination Examination Extent Definitions (FROM - TO)

Term Definition TEH Tube End - Hot Leg TSH Hot Leg Tubesheet (Secondary Face)

TEC Tube End - Cold Leg TSC Cold Leg Tubesheet (Secondary Face) 01H 1 st Tube Support Plate on Hot Leg Side 01C 1st Tube Support Plate on Cold Leg Side AVB1 1 st Anti-Vibration Bar (Numbered Hot Leg to Cold Leg)

Page 9 of 9

Attachment A BEAVER VALLEY UNIT #2 2R16 SG EXAMINATION RESULTS 2RCS-SG21A TUBES WITH SERVICE INDUCED INDICATIONS

ROW COL 1

5 1

1 2

2 2

2 2

2 2

2 2

2 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

4 4

4 4

30 68 10 56 78 79 87 88 88 89 92 93 15 15 17 26 26 27 27 30 33 33 34 47 59 64 71 77 79 81 81 81 81 84 85 91 92 6

9 9

18 Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

INO ONI LOC 05H ONI 04H ONI 08C ONI 04H ONI 04H ONI 05H ONI 04H ONI 05H OSI 02H ONI 06H ONI 07H OSI 03H PSI 08H OSI 03H ONI 07H ONI 06H ONI 03H ONI 08H ONI 06H ONI 07H ONI 04H ONI 04H ONI 08H ONI 04H ONI 07H OSI 02H ONI 04H ONI 08H ONI 08H OSI 07H ONI 08C OSI Q3H ONI 04H ONI 07H OSI 03H OSI 04H ONI 04H OSI 02H ONI 06H OSI 03H OSI 04H OSI 05H INCH

%TW LENGTH ANGLE 0.00 0.00 0.00

-0.06 0.00 0.00 0.00 0.00 0.00 0.00 0.00

-0.12

-0.13 0.07 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.22 0.00 0.00 0.00

-0.19 0.00 0.00 0.00 0.03 0.06 0.18 0.01 0.07 0.00

-0.01 0.13 0.00 Page 1 of 29 VOLTS PHASE CHAN 1.50 1.36 1.63 1.69 1.33 1.37 1.48 1.78 0.24 1.74 1.29 0.39 7.48 0.58 1.29 1.26 1.74 1.30 1.52 1.78 1.31 1.29 1.25 1.37 1.30 0.66 1.85 1.48 1.35 0.75 1.45 1.10 1.98 1.89 0.82 0.99 1.69 0.31 1.26 0.89 0.44 0.80 29 27 44 30 22 27 27 44 100 41 51 94 259 88 44 50 42 40 32 28 35 43 37 43 38 67 50 53 51 125 40 92 54 53 66 55 28 119 12 48 79 24 P1 Pl P1 P1 P1 Pl P1 Pl P1 Pl P1 P1 8

P1 Pl P1 P1 Pl P1 Pl P1 P1 P1 Pl P1 Pl P1 Pl P1 P1 P1 Pl P1 Pl P1 Pl P1 Pl P1 P1 P1 Pl FROM 08H 08H 08C 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08C 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H TO TEH TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH

ROW COL 4

21 4

22 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

5 5

5 5

5 5

5 5

5 5

5 24 26 26 33 34 34 39 50 50 50 54 54 54 54 54 60 60 62 62 62 63 6S 70 72 76 76 7S SO S5 4

4 10 10 10 11 12 13 23 23 25 Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

IND OSI ONI LOC 03H 07H OSI 02H OSI 02H ONI 04H PSI 03C OSI 03H ONI OSH OSI 02H OSI 02H OSI 03H OSI 04H ONI OSC OSI 02H ONI 03H OSI 04H OSI 05H OSI 02H OSI 06H ONI 02H ONI 03H ONI 05H OSI 02H ONI 04H ONI 05H ONI OSH ONI 05H ONI 06H OSI 05H ONI 04H OSI OSC ONI 06H ONI 07H OSI 02H OSI 03H OSI 04H OSI 04H ONI OSH ONI 06H OSI 02H ONI 06H OSI 05H INCH

%TW LENGTH 0.00 0.13

-0.07

-0.01

-0.16 0.00

-0.27 0.01

-0.03 0.10

-0.03 0.01 0.00 0.00 0.00 0.12 0.04 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

-0.02 0.00 0.00

-0.02

-0.02 0.07 0.00

-0.01 0.05 0.00 0.10 ANGLE Page 2 of 29 VOLTS PHASE CHAN 0.61 1.32 0.54 0.S2 1.50 7.SS 0.72 1.67 0.35 0.34 0.92 0.96 1.50 0.5S 2.3S 0.31 0.61 0.19 0.3S 1.61 2.02 1.59 0.50 1.43 1.30 1.55 1.26 1.26 0.39 1.29 0.23 1.26 1.41 1.37 0.54 0.54 0.56 1.54 1.S3 0.46 1.64 0.61 67 37 30 39 45 164 6S 54 33 3S 37 30 42 47 55 45 57 lOS 34 51 26 32 45 51 4S 49 57 59 61 47 50 42 36 52 114 Sl 33 41 21 71 3S 102 Pl Pl Pl Pl Pl S

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM OSH OSH OSH OSH OSH OSC OSH OSH OSH OSH OSH OSH OSC OSH OSH OSH OSH OSH OSH OSH OSH OSH OSH OSH OSH OSH OSH OSH OSH OSH OSC TEH TEH TEH TEH TEH TEH TEH OSH TEH TEH OSH TO TEH TEH TEH TEH TEH TEe TEH TEH TEH TEH TEH TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEC TEH

ROW COL 5

25 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

25 26 26 28 30 31 35 50 53 53 53 65 71 77 80 82 89 6

11 14 15 17 18 27 27 32 33 33 34 34 34 35 35 35 35 35 36 36 37 40 40 Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

IND DNI LOC 06H DNI 08H DSI 02H DSI 03H DNI 04H DSI 03H DNI 06H DNI 04H DNI 04H DSI 02H DNI 04H DNI 07H DNI 08H DNI 08H DNI 08H DSI 05H DSI 03H DNI 05H DNI 08H DNI 06H DNI 06H DSI 02H DNI 04H DNI 04H DSI 06H DNI 07H DSI 02H DNI 04H DNI 08H DSI 02H DNI 04H DNI 08H DSI 02H DSI 03H DSI 05H DNI 06H DNI 08H DNI 07H DNI 08H DNI 07H DSI 03H DSI 04H INCH

%TW LENGTH 0.00 0.00 0.04

-0.01 0.00 0.00 0.00 0.24 0.00 0.07 0.00 0.00 0.00 0.00 0.00 0.12 0.00 0.28 0.00 0.00 0.00 0.05 0.00 0.00 0.02 0.00 0.05 0.00 0.00 0.07 0.00 0.00

-0.10 0.00

-0.05 0.00 0.00 0.00 0.00 0.07 0.02 0.10 ANGLE Page 3 of 29 VOLTS PHASE CHAN 1.92 1.57 0.35 0.60 1.53 0.55 1.44 1.30 1.27 0.30 1.43 1.44 1.29 1.62 1.31 0.33 0.37 1.25 1.33 1.57 1.28 0.34 1.41 1.33 0.31 2.26 0.29 1.28 1.33 0.27 1.56 1.61 0.97 0.47 0.33 1.50 1.34 1.34 1.67 1.41 0.27 0.27 36 38 126 71 36 20 53 31 23 48 44 41 48 43 39 44 66 34 39 42 48 80 48 47 91 31 115 30 30 132 54 40 95 81 70 48 48 45 39 51 99 87 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM 08H 08H 08H 08H 08H 08H TEH TEH 08H TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TEH TEH TEH TEH TEH TEH TEC TEe TEH TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO DNI DSI LOC 08H 02H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN 6

40 6

43 0.07 6

6 6

6 6

6 6

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 43 DNI 07H 0.07 62 DNI 04H 0.00 63 DNI 04H 0.00 63 DNI 08H 0.00 65 DNI 08H 0.00 68 DNI 05H 0.00 68 DNI 07H 0.00 4

DNI 06H

-0.10 4

DNI 07H 0.00 5

DNI 04H 0.00 5

DNI 05H 0.00 6

DNI 04H

-0.26 6

DNI 05H 0.00 14 DSI 03H 0.19 18 DSI* 03H 0.00 18 DNI 04H 0.00 18 DSI 05H 0.02 19 DSI 03H 0.07 27 DSI 05H 0.07 31 DNI 05H 0.02 31 DNI 07C

-0.29 31 DNI 07H 0.00 48 SCI TSH

-0.11 49 DSI 02H 0.05 49 DNI 05H 0.00 49 DNI 07H 0.00 51 DSI 02H

-0.02 57 DNI 02H 0.00 57 DNI 05H 0.19 57 DNI 07H 0.02 58 DSI 03H 0.02 60 DNI 03H 0.00 60 DNI 08H 0.00 63 DNI 08H 0.00 64 SCI TSH

-0.16 69 DNI 03H 0.00 71 DSI 03H 0.05 71 DNI 05H 0.02 72 DNI 04H 0.00 74 MCI TSH

-0.06 Page 4 of 29 1.26 44 Pl 0.52 1.26 1.61 1.70 1.61 1.33 1.91 2.02 1.53 1.44 1.54 1.44 1.87 1.46 0.26 0.55 1.75 0.22 0.63 0.34 1.31 1.65 1.50 0.16 0.21 1.56 1.31 0.57 1.38 1.76 1.59 0.59 1.25 1.36 1.34 0.15 1.33 0.54 1.33 1.36 0.24 54 54 51 57 35 23 42 39 47 40 53 46 45 34 117 73 55 125 55 129 23 25 45 130 110 15 39 26 40 27 22 40 32 25 39 94 30 63 35 44 32 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl P2 FROM TEH TEH TO TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEH TEH TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO MCI ONI ONI MCI ONI ONI ONI ONI ONI LOC TSH 06H 07H TSH 07C 06H 07H 08H 05H INCH

%TW LENGTH

-0.13 ANGLE 317 0

VOLTS PHASE CHAN 7

75 7

78

-0.02 7

78 0.00

-0.11 0.00

-0.02 0.00 0.00 0.00 7

80 7

82 7

83 7

83 7

83 7

84 7

7 7

7 7

7 7

7 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

84 ONI 08H 0.22 86 ONI 08C 0.00 87 ONI 05H 0.00 87 ONI 07H

-0.02 87 ONI 08H 0.00 88 ONI 07H 0.00 88

. ONI 08H 0.00 94 OSI 02H 0.09 2

ONI 05H 0.00 19 OSI 02H 0.00 19 ONI 03H 0.00 28 OSI 02H 0.00 28 ONI 07H 0.00 28 ONI 08H 0.00 29 OSI 02H 0.05 32 OSI 03H 0.00 32 ONI 05H 0.07 32 ONI 07H 0.02 32 ON I 08H 0.00 33 SCI TSH 0.00 34 OSI 03H 0.00 39 SCI TSH

-0.19 42 OSI 02H 0.07 42 ONI 08H 0.00 52 ONI 07H 0.00 52 ONI 08H 0.00 56 ONI 03H 0.00 56 ONI 07H 0.00 56 ONI 08H 0.00 59 ONI 08H 0.00 61 ONI 04H 0.00 64 ONI 03H 0.00 65 ONI 07H 0.00 Page 5 of 29 0.22 31 P2 1.56 1.44 0.24 1.36 1.38 1.48 1.51 1.36 1.39 1.38 1.60 1.65 1.42 1.30 1.29 0.27 1.44 0.54 1.49 0.33 1.34 1.42 0.26 0.27 1.66 1.75 1.68 0.28 1.25 0.36 0.33 1.39 1.38 1.32 1.58 1.35 1.61 1.58 1.34 1.52 1.48 55 49 43 45 55 54 44 35 37 34 53 43 46 48 36 154 43 124 36 58 43 35 127 100 21 15 28 56 45 116 104 28 27 28 44 30 34 44 24 54 50 Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TSH TEH TEH TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TSH TEC TEC TSH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEH TEC TSH TSH TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO ONI DNI DNI DNI DNI DNI DNI DNI ONI DNI LOC 08H 03H 05H 06H 08H 04H 08H 03H 04H 06H INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN 8

65 0.00 8

66 0.00 8

66 0.00 8

66 0.00 8

66 0.00 8

69 0.17 8

69 0.00 8

74 0.00 8

74 0.00 8

74 0.00 8

74 DNI 07H 0.00 8

74 DNI 08H 0.00 8

76 DSI 05H 0.02 8

76 DNI 08H 0.00 8

79 DNI 08H 0.00 8

85 DSI 02H 0.05 8.

91 DSI 04H 0.12 9

4 DNI 07H 0.00 9

10 DSI 02H 0.02 9

10 DNI 05H 0.00 9

10 DNI 06H 0.00 9

13 DSI 02H 0.07 9

14 DSI 03H 0.10 9

16 DSI 02H 0.12 9

16 DSI 03H 0.02 9

16 DSI 04H 0.02 9

22 DSI 03H 0.05 9

25 DNI 04H 0.00 9

25 DNI 06H 0.00 9

27 DNI 03H 0.00 9

27 DNI 04H 0.00 9

28 DNI 08e

-0.02 9

29 DNI 06H 0.00 9

31 DNI 06H 0.06 9

9 9

9 9

9 9

9 34 DSI 02H 0.14 34 SAl 02H

-0.23 35 DSI 02H 0.07 35 DNI 08H 0.02 37 DNI 04H

-0.05 37 DNI 05H 0.00 37 DNI 06H

-0.12 37 DNI 08H 0.00 0.15" Page 6 of 29 1.33 1.62 1.35 1.32 1.60 1.63 1.47 1.69 1.70 1.32 1.55 1.57 0.34 1.34 1.35 0.21 0.53 1.30 0.78 1.44 1.46 0.89 0.36 0.46 0.80 0.60 0.54 1.75 1.29 1.58 1.66 1.45 1.35 1.49 0.29 0.14 0.36 1.39 2.25 1.35 1.92 1.98 47 53 36 43 43 43 47 48 55 49 44 39 56 40 28 32 49 42 51 43 43 52 64 80 64 123 71 54 47 55 55 40 50 22 120 91 117 46 21 25 23 25 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH 02H TEH TEH TEH TEH TEH TEH TEe 02H TEe TEe TEe TEe TEe TEe

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO OSI ONI LOC 05H 07H INCH

%TW LENGTH 0.25 ANGLE VOLTS PHASE CHAN 9

38 9

38 0.00 9

9 9

9 9

9 9

9 9

9 39 40 40 42 44 49 ONI 07H OSI 03H ONI 07H ONI 04H ONI 07H ONI 08H

-0.17 0.05 0.02

-0.07 0.00 0.00 51 SCI TSH 0.15 51 OSI 04H 0.10 51 SAl 04H

-0.11 53 SCI TSH 0.02 9

56 OSI 02H 0.00 9

56 OSI 04H 0.10 9

57 OSI 02H 0.10 9

57 OSI 03H

-0.05 9

57 ONI 04H 0.00 9

57 ONI 06H 0.00 9

57 ONI 07H 0.00 9

59 ONI 04H 0.00 9

59 ONI 07H 0.00 9

65 ONI 02H 0.00 9

65 ONI 06H 0.00 9

65 ONI 07H 0.00 9

74 OSI 03H 0.07 9

85 ONI 08C 0.00 9

86 ONI 04H 0.00 10 7

OSI 02H

-0.07 10 7

OSI 03H 0.02 10 7

ONI 06H 0.00 10 8

OSI 03H

-0.07 10 19 OSI 04H 0.05 10 26 OSI 04H 0.10 10 29 ONI 07H 0.00 10 37 OSI 03H 0.05 10 47 ONI 02H

-0.07 10 47 ONI 03H

-0.07 10 47 ONI 04H 0.07 10 47 ONI 05H 0.02 10 47 ONI 06H 0.05 10 47 ONI 07H

-0.12 10 49 ONI 08H 0.02 0.22" Page 7 of 29 0.64 1.51 1.19 0.49 1.61 1.54 1.37 1.43 0.56 0.47 0.10 0.13 0.52 0.25 0.19 0.38 1.37 1.26 1.40 1.90 1.63 1.74 1.30 1.46 0.38 1.29 1.66 1.08 0.23 1.57 0.62 0.34 0.32 1.92 0.26 1.36 1.26 1.35 1.63 1.67 1.44 1.40 60 44 20 87 38 39 43 42 27 11 94 75 61 62 123 80 39 43 47 51 36 55 39 48 76 36 54 49 115 45 57 86 94 24 114 43 35 46 31 25 20 12 Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl 6

P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TSH TEH 04H TSH TO TEC TEC TEC TEC TEC TEC TEC TEC TSH TEC 04H TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 51 57 57 57 57 57 57 57 57 58 58 64 64 72 75 75 86 89 89 2

3 3

3 5

5 5

5 12 12 20 29 29 40 42 42 48 ONI 04H ONI 02H ONI 03H ONI 04H ONI 05H ONI 06H ONI 07H ONI 08C ONI 08H ONI 07C ONI 08C ONI 02H ONI 03H ONI 07H ONI 05H ONI 08H ONI 08C ONI 06H ONI 07H OSI 03H ONI 04H ONI 05H ONI 07H ONI 04H ONI 05H ONI 06H ONI 07H ONI 04H ONI 05H ONI 06H ONI 05H ONI 07H ONI 07H ONI 06H ONI 07H OSI 02H 0.00

-0.09 0.00 0.00 0.02 0.00 0.00

-0.07 0.00 0.00 0.00

-0.07 0.07 0.00 0.00 0.00 0.00 0.00 0.00 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

-0.10 0.00 0.00 0.00 0.00 0.00 0.00 0.10 48 ONI 06H 0.00 48 ONI 07H 0.00 48 OSI 08H 0.05 49 SCI TSH

-0.05 65 ONI 03H 0.00 65 ONI 05H

-0.34 Page 8 of 29 1.25 1.66 1.32 1.56 1.93 1.54 1.89 1.32 1.53 1.82 1.39 2.05 1.39 1.31 1.49 1.74 1.30 2.15 1.60 0.77 2.34 1.73 1.48 2.15 1.99 1.47 1.40 1.62 1.52 1.46 1.51 1.37 1.67 1.34 2.01 0.93 1.84 2.26 0.37 0.29 1.36 1.26 42 23 27 32 19 19 28 21 22 16 37 8

27 16 55 23 41 29 37 81 37 44 39 41 41 52 44 52 48 47 20 31 37 43 20 43 38 34 55 123 55 55 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TSH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TSH TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO ONI ONI LOC 03H 08H INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN 11 74 0.00 11 75 0.00 11 11 11 11 11 11 11 11 11 11 11 11 11 11 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 76 76 76 77 77 77 77 78 79 80 80 83 89 89 7

27 31 31 34 34 38 48 49 58 64 64 66 67 67 69 69 ONI 03H ONI 06H ONI 07H ONI 03H OSI 05H ONI 06H ONI 07H OSI 06H ONI 08C ONI 06H ONI 07H ONI 04H ONI 05H ONI 07H ONI 04H ONI 05H ONI 06H ONI 07H OSI 02H ONI 06H ONI 06H OSI 05H SCI TSH ONI 04H ONI 04H ONI 05H ONI 02H ONI 05H ONI 08C OSI 03H ONI 08C 0.00 0.00 0.00 0.17 0.10 0.10 0.00 0.00 0.00 0.00 0.12

-0.07 0.14 0.00 0.00 0.00 0.00 0.00 0.07

-0.14 0.00

-0.02

-0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.07 0.00 70 OSI 03H 0.10 71 ONI 06C 0.00 71 ONI 07C

-0.05 71 ONI 07H 0.00 71 ONI 08H 0.00 72 OSI 02H 0.05 72 ONI 03H

-0.07 72 ONI 05H 0.05 72 ONI 08H 0.00 Page 9 of 29 1.25 1.39 1.47 1.33 1.40 1.33 0.48 1.78 1.39 0.31 1.35 1.38 1.50 1.52 1.44 1.26 1.26 1.63 1.33 1.29 0.44 1.99 1.33 0.59 0.31 1.24 1.98 1.37 1.61 1.40 1.41 0.39 1.35 0.55 1.86 1.44 1.30 2.05 0.29 1.16 1.65 1.48 47 51 45 51 51 51 43 48 54 22 38 52 52 52 24 46 15 18 22 22 77 33 23 80 39 45 48 45 63 53 39 67 37 62 32 38 53 32 76 62 48 49 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TSH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DNI DNI DNI DSI LOC 06H 07H 08C 02H INCH

%TW LENGTH 0.00 12 73 12 73 0.00 12 73 0.00 12 74 0.05 12 12 12 12 12 12 12 12 12 13 13 13 13 13 13 13 74 75 75 DSI 03H DNI 02H DNI 03H

-0.02 0.02 0.00 75 DNI 05H 0.17 75 DNI 06H 0.00 85 MCI TSH

-0.17 89 DNI 04H 0.00 89 DNI 06H 0.00 89 DNI 08H 0.00 4

DNI 03H 0.00 4

DNI 04H 0.00 4

DNI 05H* 0.00 4

DNI 06H*

0.00 4

DNI 07H 0.00 11 DNI 07H 0.00 13 DNI 07H 0.00 13 21 DNI 04H 0.00 13 22 DNI 06H 0.00 13 22 DNI 07H 0.00 13 29 DNI 05H 0.00 13 29 DNI 06H 0.02 13 29 DNI 08H 0.00 13 32 DSI 02H 0.00 13 39 DSI 05H 0.12 13 39 DNI 08H 0.00 13 41 DNI 03H 0.00 13 41 DNI 07H 0.00 13 42 DNI 07H 0.00 13 49 DSI 04H 0.12 13 57 DNI 04H 0.02 13 57 DNI 06H 0.00 13 57 DNI 07H 0.07 13 60 DSI 02H 0.10 13 67 DNI 05H 0.00 13 67 DNI 07H 0.00 13 67 DNI 08H 0.00 13 71 DSI 04H 0.05 13 73 DNI 05H 0.00 ANGLE Page 10 of 29 VOLTS PHASE 1.45 51 1.79 40 1.40 39 0.54 139 0.87 2.34 1.87 1.91 1.47 0.08 1.47 1.35 1.26 1.86 1.38 1.27 1.31 1.51 1.28 1.29 1.32 1.58 1.78 1.29 1.32 1.27 0.32 0.20 1.38 1.26 1.50 1.33 0.16 1.50 1.35 1.69 0.18 1.44 1.43 1.31 0.33 1.27 35 42 45 29 46 103 54 54 50 30 53 44 41 29 26 33 40 43 33 34 39 28 43 90 32 25 22 27 55 45 40 35 142 40 51 45 23 46 CHAN Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TEH TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TEC TEC TEC TEC TEC TEC TEC TEC TEC TSH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO DNI SCI LOC 08H TSH INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN 13 73 13 74

-0.02 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 80 80 83 83 84 85 85 85 85 85 86 86 86 87 87 87 89 91 92 15 15 20 20 25 27 31 DSI 03H DNI 08H DNI 06H DNI 07H DSI 02H DSI 02H DNI 05H DNI 06H DNI 07C DNI 08C DSI 03H DNI 07H DNI 08H DNI 02H DNI 03H DNI 08C DNI 08H DSI 05H DSI 04H DNI 03H DSI 04H DSI 03H DNI 08C DSI 05H DSI 05H DSI 02H 0.07 0.00 0.07

-0.02 0.07 0.05 0.10 0.12

-0.10 0.00 0.10 0.15 0.12 0.05

-0.10 0.00 0.00 0.12 0.05 0.05

-0.05

-0.05 0.00 0.05 0.05 0.10 39 DNI 03H 0.00 39 DNI 04H 0.00 39 DNI 06H 0.00 40 DSI 05H 0.02 40 SAl 05H

-0.14 42 DNI 02H 0.00 42 DNI 06H 0.00 43 DNI 06H 0.00 47 DNI 03H 0.00 48 DSI 05H 0.00 48 DN I 08H 0.00 49 DNI 06H 0.00 49 DNI 07H 0.00 49 DNI 08H 0.00 0.26" Page 11 of 29 1.26 0.33 0.47 1.45 1.89 2.08 0.49 0.64 1.48 1.60 2.01 1.69 0.42 1.73 1.85 1.98 1.27 2.10 1.29 0.56 0.61 1.90 0.25 0.54 1.42 0.28 0.35 0.28 1.35 1.26 1.49 0.43 0.13 1.61 1.38 1.28 1.26 0.40 1.38 1.25 1.41 1.46 36 78 55 41 43 38 44 54 50 49 28 32 78 45 40 55 54 29 54 73 72 18 52 50 31 93 145 23 51 49 38 10 69 53 38 27 40 126 59 47 52 42 Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TEC TSH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC 05H 05H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL 14 50 14 53 14 53 14 53 14 54 14 54 14 54 INO DSI DSI DNI DNI DSI DNI DNI LOC 03H 02H 06H 07H 02H 05H 06H INCH

%TW LENGTH 0.07 0.02 0.02 0.00 0.14

-0.02 0.07 14 54 DNI 07H 0.00 14 55 DNI 05H 0.00 14 58 DSI 02H

-0.17 14 58 DNI 08H 0.00 14 59 DSI 02H 0.10 14 59 DSI 03H 0.12 14 59 DSI 06H 0.15 14 59 DNI 08H 0.00 14 60 DNI 08H 0.00 14 61 DNI 06H 0.00 14 61 DNI 08H 0.00 14 63 DNI 04H 0.00 14 64 DNI 03H 0.00 14 64 DNI 04H 0.00 14 65 DNI 02H 0.00 14 65 DSI 03H

-0.02 14 65 DNI 08H 0.00 14 66 DNI 08H 0.00 14 67 DNI 07H 0.00 14 68 DSI 02H 0.10 14 70 DSI 03H 0.00 14 71 DNI 03H 0.00 14 71 DN I 08H 0.00 14 73 DNI 06H 0.00 14 73 DNI 07H 0.00 14 77 DNI 08H

-0.02 14 80 DSI 03H 0.00 14 86 DSI 04H 0.02 14 87 DNI 03H 0.00 14 87 DNI 08H 0.00 15 4

DNI 08H 0.00 15 6

DNI 06H 0.00 15 27 DSI 05H

-0.07 15 35 DN I 06H 0.05 15 40 DNI 06H 0.00 ANGLE Page 12 of 29 VOLTS PHASE CHAN 0.36 82 Pl 0.28 50 Pl 1.31 1.30 0.48 1.71 1.74 1.34 1.48 0.60 1.28 0.36 0.25 0.57 1.80 1.43 1.85 1.42 1.86 1.59 2.08 3.10 0.42 1.41 1.40 1.37 0.41 0.79 1.27 1.34 1.86 1.96 1.69 0.35 0.55 1.47 1.38 1.26 1.41 0.22 1.45 1.54 44 49 68 54 43 51 35 101 50 100 60 136 32 53 41 42 52 50 54 42 82 47 51 53 43 131 51 41 40 35 40 66 33 53 41 31 24 68 42 37 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TO TEe TEe TEe TEe TEe TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEC TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DNI DNI DNI DNI DNI DNI SCI DNI LOC 07H 08H 03H 08H 04H 07H TSH 04H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN 15 40 15 40 0.00 15 50 0.00 15 50 0.00 15 54 0.00 15 57 0.00 15 59

-0.11 15 60 0.00 15 63 DSI 02H 0.10 15 63 DNI 06H 0.02 15 64 DNI 03H 0.00 15 65 DNI 03H 0.05 15 65 DNI 04H 0.00 15 66 DNI 02H 0.00 15 66 DNI 03H 0.02 15 67 DSI 02H 0.02 15 67 DNI 03H 0.00 15 67 DNI 04H 0.00 15 68 DNI 05H 0.00 15 70 DNI 03H 0.00 15 71 DSI 02H 0.07 15 72 DSI 02H 0.05 15 73 DSI 05H 0.02 15 73 DNI 07H 0.00 15 74 DSI 03H

-0.02 15 74 DNI 05H 0.12 15 74 DNI 06H 0.00 15 74 DNI 07H 0.00 15 74 DNI 08H 0.00 15 75 DSI 02H 0.00 15 76 DNI 07H 0.00 15 76 DNI 08H 0.00 15 80 DNI 02H 0.00 15 80 DNI 03H 0.00 15 80 DNI 04H 0.00 15 15 15 15 15 15 15 80 DNI 05H 0.00 80 DNI 07H 0.00 80 DNI 08H 0.00 82 DSI 03H 0.05 82 DNI 07H 0.00 85 SCI TSH

-0.01 85 DNI 03H 0.02 Page 13 of 29 1.35 1.69 1.35 1.28 1.43 1.28 0.18 1.38 0.37 1.69 1.31 1.57 1.26 1.52 1.51 0.42 1.35 1.30 1.29 1.48 0.30 0.33 0.25 1.50 0.97 1.61 1.42 1.79 1.72 0.28 1.30 1.40 2.02 1.44 2.09 1.91 1.67 1.80 0.93 1.42 0.19 1.87 41 30 37 49 45 42 100 54 51 32 52 44 52 54 47 32 53 49 42 49 49 40 85 51 39 36 47 40 39 99 48 32 50 60 47 47 31 40 42 50 39 35 Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl FROM TEH TEH TEH TEH TEH TEH TSH TEH TO TEe TEe TEe TEe TEe TEe TSH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TSH TsH TEH TEe

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 15 85 ONI 06H 0.07 15 85 ONI 08e 0.00 16 32 ONI 05H 0.00 16 40 ONI 03H 0.00 16 40 ONI 04H 0.00 16 40 ONI 05H 0.00 16 40 ONI 06H 0.00 16 40 ONI 07H 0.00 16 44 ONI 04H 0.07 16 44 ONI 05H 0.02 16 50 ONI 07H 0.00 16 51 ONI 03H 0.00 16 52 OSI 02H 0.14 16 52 ONI 07H 0.00 16 53 OSI 03H 0.02 16 54 ONI 08H 0.00 16 55 ONI 03H 0.00 16 55 ONI 04H 0.00 16 55 ONI 07H 0.00 16 56 ONI 07H 0.00 16 57 ONI 04H 0.00 16 57 ONI 06H 0.00 16 57 ONI 08e 0.00 16 57 ONI 08H 0.00 16 59 ONI 02H 0.17 16 59 ONI 03H

-0.02 16 59 OSI 04H

-0.15 16 59 ONI 07H 0.00 16 62 OSI 08H 0.03 16 63 ONI 05H 0.10 16 66 OSI 03H 0.00 16 72 OSI 02H 0.05 16 72 ONI 05H 0.00 16 76 OSI 02H

-0.05 16 77 OSI 05H 0.07 16 84 ONI 06H 0.00 16 16 16 16 17 17 84 ONI 07H 0.00 84 ONI 08H 0.00 86 Mel TSH

-0.06 88 ONI 04H 0.00 6

ONI 02H 0.00 10 OSI 03H 0.02 Page 14 of 29 2.62 28 1.84 25 1.26 48 1.56 48 1.39 55 1.61 36 1.64 38 1.35 41 1.33 17 1.33 20 1.30 51 1.47 55 0.48 140 1.54 32 0.36 49 1.31 52 1.61 48 1.77 51 1.29 49 1.63 41 1.48 44 1.69 41 1.64 32 2.12 30 1.57 52 2.20 45 1.16 44 1.74 35 0.14 40 1.36 49 0.40 41 0.22 66 1.77 45 0.42 102 0.17 55 1.29 55 1.58 1.40 0.18 1.29 1.34 0.37 46 46 62 33 15 151 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TSH TSH TEH TEe TEH TEe TEH TEe

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO SCI OSI ONI OSI ONI ONI ONI OSI LOC TSH 04H 04H 05H 06H 05H 07H 02H INCH

%TW LENGTH

-0.05 ANGLE 45° VOLTS PHASE CHAN 17 23 17 27 0.07 17 31 0.00 17 32 0.12 17 35

-0.22 17 39 0.00 17 40 0.00 17 46 0.00 17 46 ONI 03H 0.00 17 46 ONI 04H 0.00 17 49 ONI 04H

-0.02 17 51 ONI 05H 0.12 17 51 ONI 07H

-0.12 17 51 ONI 08H 0.00 17 53 ONI 03H 0.07 17 54 ONI 08H 0.00 17 55 ONI 02H 0.00 17 55 ONI 03H 0.00 17 58 ONI 07H 0.02 17 59 OSI 02H 0.15 17 59 ONI 04H 0.00 17 59 OSI 05H 0.10 17 66 ONI 03H 0.05 17 67 ONI 04H 0.00 17 76 ONI 02H 0.00 17 76 ONI 03H 0.00 17 76 ONI 07H 0.00 17 81 OSI 04H

-0.05 17 17 17 85 ONI 05H 0.00 87 SCI TSH

-0.11 90 ONI 02H 0.00 18 7

OSI 04H 0.07 18 10 OSI 03H 0.07 18 10 OSI 04H 0.00 18 15 ONI 08H 0.05 18 27 OSI 07H 0.00 18 32 ONI 07H 0.00 18 32 ONI 08H 0.00 18 43 ONI 05H 0.10 18 43 ONI 06H

-0.05 18 43 ONI 07H 0.00 18 47 OSI 02H 0.02 Page 15 of 29 0.19 0.36 1.64 0.65 1.43 1.65 1.41 0.76 1.43 1.43 1.58 1.51 1.46 1.88 1.70 1.82 1.28 1.33 1.28 0.24 1.26 0.23 1.66 1.36 1.96 1.81 1.77 0.39 1.33 0.17 1.60 0.22 0.36 0.25 2.04 0.50 1.37 1.30 1.32 1.33 1.41 0.23 101 56 20 36 29 20 24 23 22 19 22 43 42 36 51 41 48 46 48 124 43 91 54 48 56 43 44 44 49 72 18 91 150 56 15 122 44 46 48 46 36 48 P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TSH TEH TEH TEH TEH TEH TEH TEH TO TSH TEC TEC TEC TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TSH TEH TEC TSH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 47 48 48 52 52 55 55 55 55 55 56 56 56 57 57 57 57 57 57 57 58 61 83 88 7

7 8

8 8

13 15 15 15 20 54 56 56 56 56 56 57 57 OSI 05H ONI 07H ONI 08H ONI 03H ONI 06H ONI 03H ONI 04H ONI 05H ONI 06H ONI 07H ONI 04H ONI 05H ONI 07H OSI 02H ONI 03H ONI 04H ONI 05H ONI 06H ONI 07H ONI 08H ONI 04H ONI 04H ONI 08H OSI 05H OSI 02H ONI 03H OSI 03H ONI 04H ONI 05H ONI 04H OSI 03H OSI 04H ONI 06H ONI 08H ONI 03H OSI 03H ONI 04H ONI 06H ONI 07H ONI 08H OSI 02H OSI 04H 0.05 0.00 0.00 0.00 0.00 0.00 0.00

-0.05 0.00 0.00

-0.19 0.00 0.00 0.05

-0.10 0.12 0.17 0.00 0.00

-0.07

-0.17 0.00 0.00 0.10 0.05 0.00 0.00 0.00 0.00 0.00

-0.02 0.00 0.00 0.00 0.00

-0.24

-0.19 0.00 0.00 0.00 0.12 0.12 Page 16 of 29 0.90 1.97 2.03 1.81 1.25 1.88 1.79 2.32 1.82 1.31 0.77 1.60 1.55 0.99 1.30 1.41 1.41 1.77 1.87 1.57 1.30 1.26 1.28 0.36 0.68 1.79 0.25 1.48 1.31 1.46 0.30 0.26 1.28 1.34 1.25 0.15 0.85 1.59 1.35 1.25 0.59 0.25 35 37 32 56 43 55 45 39 36 46 56 58 46 62 46 38 38 44 38 29 52 30 40 38 44 42 98 43 50 16 115 60 51 43 24 78 49 44 49 42 119 79 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC 19 57 ONI 08H 0.07 19 59 ONI 02H 0.02 19 19 19 19 19 19 19 19 19 19 19 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 59 59 59 60 60 60 60 60 69 70 78 9

9 10 10 11 12 15 20 ONI 03H ONI 04H ONI 05C OSI 02H ONI 03H ONI 07H ONI 08C ONI 08H ONI 08H ONI 06H ONI 05H OSI 03H ONI 07H ONI 03H OSI 04H ONI 04H OSI 02H ONI 07H ONI 05H 0.00 0.05 0.02 0.07

-0.17 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.00 0.05

-0.07 0.00 0.05 0.00 0.00 22 OSI 02H 0.00 22 OSI 03H 0.10 22 ONI 04H 0.00 22 OSI 08H 0.00 24 ONI 06H 0.10 30 ONI 05H 0.00 36 ONI 06H 0.00 37 MCI TSH

-0.11 57 OSI 02H 0.10 57 ONI 06C

-0.07 57 ONI 07C 0.00 58 ONI 08C 0.00 61 ONI 05H 0.00 61 ONI 06H 0.00 61 ONI 07H 0.00 61 ONI 08H 0.00 62 OSI 05H

-0.07 64 PCT AVl 0.00 19%

64 PCT AV2 0.00 25%

64 PCT AV3 0.00 19%

66 SCI TSH 0.05 Page 17 of 29 1.57 39 Pl TEH 1.53 32 Pl TEH 1.65 3.02 2.26 0.34 1.63 1.42 1.15 1.11 1.26 1.26 1.28 0.32 1.34 1.27 0.35 1.27 0.45 1.50 1.26 0.73 0.44 1.36 0.43 1.71 1.32 1.47 0.26 0.21 1.95 1.46 1.69 1.32 1.46 1.33 1.56 0.38 1.04 1.65 1.07 0.13 45 32 16 42 52 45 36 50 36 39 52 131 36 55 45 47 24 35 48 120 58 26 30 14 51 46 80 88 20 28 18 56 48 43 37 135 o

o o

104 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 P2 P2 P2 TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL 20 78 20 78 20 85 20 89 21 7

21 12 21 13 21 13 INO OSI ONI OSI ONI ONI ONI ONI ONI LOC 04H 08H 03H 06H 08H 07H 05H 07e INCH

%TW LENGTH 0.07 0.00 0.05 0.05 0.00 0.00 0.00 0.00 21 18 OSI 04H 0.02 21 21 ONI 05H 0.00 21 21 ONI 07H

-0.05 21 25 OSI 03H 0.07 21 26 OSI 05H 0.00 21 34 OSI 02H 0.10 21 40 ONI 07H 0.00 21 42 ONI 06H 0.00 21 42 ONI 07H 0.00 21 42 ONI 08H 0.00 21 43 OSI 02H 0.07 21 43 ONI 04H 0.00 21 43 ONI 05H 0.00 21 43 ONI 06H 0.00 21 45 ONI 06H 0.00 21 45 ONI 07H 0.00 21 46 OSI 02H 0.02 21 46 ONI 07H 0.00 21 48 ONI 02H 0.10 21 48 ONI 03H 0.02 21 48 ONI 04H

-0.02 21 48 ONI 05H 0.05 21 48 ONI 06H 0.07 21 48 ONI 07H 0.05 21 50 ONI 03H 0.00 21 51 ONI 03H

-0.02 21 53 ONI 08H

-0.05 21 54 ONI 03H 0.00 21 54 ONI 04H 0.00 21 54 ONI 05H 0.00 21 55 OSI 02H 0.07 21 56 ONI 04H 0.00 21 60 ONI 05H 0.00 21 60 ONI 07H 0.00 ANGLE Page 18 of 29 VOLTS PHASE CHAN 0.19 92 Pl 1.40 42 Pl 0.27 1.29 1.29 1.60 1.44 1.29 0.41 1.44 1.58 0.32 0.49 0.33 1.48 1.47 1.50 1.40 0.28 1.49 1.48 1.41 1.25 1.52 0.46 1.29 1.63 1.95 1.26 2.39 1.68 1.42 1.27 1.76 1.50 1.39 1.40 1.36 0.13 1.34 1.47 1.40 54 45 34 34 34 28 172 23 20 59 95 133 42 46 43 39 142 42 45 47 50 38 92 32 33 21 20 21 33 25 24 10 23 52 47 42 53 15 38 39 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TO TEe TEe TEe TEe TEe TEe TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe

ROW COL 21 60 21 72 21 73 21 21 21 21 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 23 23 23 23 23 23 23 23 23 23 73 75 77 78 7

10 12 15 18 21 21 23 32 36 37 51 51 53 53 53 53 59 65 66 66 74 74 76 77 10 10 11 11 11 11 19 19 19 19 Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

IND ONI OSI ONI LOC 08H 03H 05H ONI 08C ONI 08C ONI 06H OSI 08H OSI 02H ONI 07C ONI 03H ONI 06H ONI 08C DSI 02H OSI 03H OSI 02H ONI 05H ONI 06H ONI 05H ONI 03H ONI 07H ONI 03H ONI 04H ONI 06H ONI 07H ONI 05H ONI 07H ONI 03H ONI 06H ONI 04H ONI 08H ONI 05H ONI 07H ONI 02H ONI 07H OSI 02H OSI 03H ONI 06H ONI 08H OSI 02H ONI 03H ONI 04H ONI 05H INCH

%TW LENGTH 0.00 0.02 0.00 0.00 0.00 0.00 0.07 0.10 0.00 0.00 0.00 0.00 0.00 0.05

-0.05 0.00 0.00 0.00

-0.12

-0.07

-0.12

-0.05 0.00 0.00 0.00 0.00 0.00 0.00

-0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.12 0.00 0.00 0.00 ANGLE Page 19 of 29 VOLTS PHASE CHAN 1.45 0.53 1.70 1.41 1.57 1.34 0.13 0.27 1.26 1.51 1.36 1.58 0.24 0.22 0.28 1.42 1.37 1.30 1.26 1.39 1.69 2.00 1.65 1.30 1.48 1.38 1.51 1.45 1.93 2.25 1.39 1.26 1.26 1.38 1.00 0.24 1.33 1.44 0.86 1.53 1.53 1.32 37 49 25 29 25 24 78 74 12 52 44 23 36 66 142 51 49 56 52 22 20 20 14 18 22 21 40 32 20 16 29 29 19 26 19 49 42 31 28 38 44 34 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO OSI OSI ONI ONI ONI ONI ONI ONI ONI LOC 02H 03H 04H 06H 07H 05H 03H 06H 07H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN 23 20 23 21 0.05 23 26 0.00 23 33 0.17 23 33 0.00 23 42 0.00 23 46 0.00 23 46 0.00 23 46 0.00 23 23 23 23 23 23 23 23 23 23 23 24 24 24 24 52 ONI 04H 0.00 53 OSI 02H 0.07 53 ONI 04H 0.00 53 ONI 05H 0.00 53 ONI 07H 0.00 53 SAl 02H 0.00 55 ONI 05H 0.00 59 ONI 06H 0.00 71 ONI 08H 0.00 80 ONI 07H 0.00 81 ONI 04H

-0.02 11 ONI 04H 0.00 16 OSI 02H 0.10 16 OSI 03H 0.05 17 ONI 05H 0.00 24 22 SCI TSH

-0.16 24 23 ONI 04H 0.00 24 23 OSI 05H 0.05 24 23 ONI 06H 0.00 24 23 SAl 05H

-0.13 24 24 OSI 02H 0.05 24 24 ONI 05H 0.00 24 29 ONI 06H 0.00 24 29 ONI 07H 0.00 24 29 ONI 08H 0.00 24 33 OSI 03H 0.00 24 37 ONI 07H

-0.17 24 39 ONI 03H

-0.02 24 24 24 24 24 40 ONI 05H 0.00 40 ONI 06H 0.00 43 ONI 05H 0.02 43 ONI 06H 0.05 47 ONI 06H 0.00 0.19" 0.35" Page 20 of 29 0.18 120 Pl 0.38 1.33 1.37 1.26 1.25 1.86 2.03 1.79 1.27 0.41 1.44 1.25 1.45 0.11 1.33 1.40 1.22 1.77 1.51 1.29 0.17 0.25 1.56 0.27 1.32 0.72 1.28 0.09 0.23 1.66 1.28 1.42 1.49 0.40 1.27 1.29 1.42 1.35 1.34 1.42 1.41 84 53 26 46 52 24 33 31 41 21 33 32 22 77 23 17 47 20 48 45 155 141 47 54 33 8

26 106 58 26 41 28 28 72 29 52 50 45 41 34 32 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH 02H TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC 02H TEC TEC TEC TEC TEC TEC TEC TEC TEC TSH TSH TEH TEC TEH TEC TEH TEC 05H 05H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL 24 48 24 51 IND DNI DNI LOC 06H 03H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN 0.07 24 52 DSI 02H 0.10 24 52 DNI 05H 0.00 24 59 DNI 04H 0.00 24 63 DSI 05H 0.12 24 64 SCI TSH 0.05 24 68 SCI TSH 0.03 24 80 DNI 05H 0.00 24 85 DNI 05H 0.00 25 21 DSI 02H 0.17 25 25 25 25 25 25 25 25 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 22 DSI 02H 0.05 30 DSI 04H 0.14 37 DNI 05H 0.00 37 Mel TSH

-0.07 53 DNI 06H 0.00 65 DNI 06H 0.00 67 73 15 15 17 28 33 33 36 36 36 36 39 40 41 42 42 43 43 43 44 45 45 45 46 DNI 04H DNI 08H DSI 03H DNI 04H DNI 08H DNI 08H DNI 05H DNI 07H DNI 03H DNI 04H DNI 06H DNI 08H DNI 04H DNI 06H DNI 06H DSI 02H DNI 06H DNI 04H DNI 05H DNI 06H DNI 07H DNI 04H DNI 05H DNI 06H DNI 04H 0.00 0.00 0.10 0.00 0.02 0.00 0.00 0.00 0.00

-0.12 0.00 0.00 0.00 0.00 0.00 0.02 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 Page 21 of 29 1.31 1.47 0.24 1.48 1.60 0.35 0.09 0.13 1.41 1.48 0.20 0.50 0.49 1.28 0.18 1.44 1.49 1.32 1.26 0.30 1.29 1.40 1.40 1.33 1.32 1.65 1.58 1.59 1.41 1.43 1.46 1.26 0.36 1.29 1.27 1.57 1.27 1.46 1.45 1.53 1.34 1.25 33 20 107 51 15 140 63 112 50 24 129 24 41 51 81 18 43 50 37 41 45 40 33 44 36 38 31 36 24 49 30 37 71 39 44 36 37 38 57 47 52 39 Pl Pl Pl Pl Pl Pl P2 P2 Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TO TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TSH TSH TSH TSH TEH TEe TEH TEe TEH TEe TEH TEH TEH TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEe TEe TEe TSH TEe TEe TEe TEe TEC TEe TEe TEe TEe TEe TEe TEe TEC TEe TEe TEe TEe TEe TEe TEe TEe TEC TEe TEe TEe TEe TEe

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND ONI ONI LOC 06H 05H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN 26 47 26 49 51 53 54 55 60 62 62 65 67 77 80 11 24 32 33 34 34 34 ONI 04H ONI 05H ONI 03H ONI 06H ONI 06H ONI 03H ONI 04H ONI 07H ONI 04H ONI 07H OSI 05H ONI 05H ONI 06H OSI 02H OSI 03H ONI 03H OSI 04H ONI 06H 0.07 0.07 0.00 0.00 0.00 0.00 0.07 0.10 0.00 0.05 0.00

-0.02 0.00 0.00 0.02 0.00 0.00 0.00 0.00 34 ONI 07H 0.00 41 MCI TSH

-0.13 42 OSI 04H 0.10 42 OSI 05H

-0.05 42 ONI 06H 0.00 42 SAl 04H 0.00 47 ONI 06H 0.07 47 ONI 07H 0.00 64 OSI 02H 0.10 64 ONI 07H 0.00 71 PCT AV2 0.00 14%

71 PCT AV3

-0.10 19%

71 PCT AV4 0.00 11%

73 ONI 07H 0.00 75 OSI 05H 0.05 75 ONI 08H 0.00 75 PCT AV3 0.00 8%

13 OSI 03H 0.10 16 ONI 03H

-0.31 17 ONI 04H 0.00 17 ONI 05H 0.00 0.27" 26 26 26 26 26 26 26 26 26 26 26 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 28 28 28 28 28 18 SCI TSH

-0.08 64° Page 22 of 29 1.36 44 Pl 1.37 1.25 1.31 1.39 1.44 1.28 1.32 1.43 1.34 1.25 1.35 0.18 1.28 1.32 0.31 0.75 1.30 0.47 1.40 1.47 0.24 0.43 0.34 1.33 0.09 1.32 1.27 0.27 1.32 0.95 1.34 0.68 1.47 0.22 1.31 0.49 0.26 1.36 1.34 1.43 0.19 50 48 51 28 21 33 23 22 25 41 40 63 35 43 55 44 50 83 46 41 36 27 24 36 61 51 45 24 41 o

o o

19 120 26 o

122 42 45 42 117 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl 6

Pl Pl Pl Pl P2 P2 P2 Pl Pl Pl P2 Pl Pl Pl Pl P2 FROM TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TSH TEH TEH TEH 04H TEH TEH TO TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TSH TEC TEC TEC 04H TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND OSI ONI OSI LOC 04H 04H 02H INCH

%TW LENGTH 0.17 ANGLE VOLTS PHASE CHAN 28 26 28 37 0.05 28 41 0.10 28 41 ONI 05H 0.00 28 42 ONI 03H 0.02 28 42 ONI 05H 0.00 28 42 ONI 06H 0.00 28 42 ONI 07H 0.00 28 44 ONI 05H 0.00 28 44 ONI 07H 0.00 28 44 ONI 08H 0.00 28 45 ONI 05H 0.00 28 46 OSI 03H 0.00 28 49 ONI 05H 0.00 28 54 OSI 02H 0.00 28 56 ONI 02H 0.00 28 28 28 28 28 28 28 28 28 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 29 56 OSI 03H 0.00 56 ONI 05H 0.00 56 ONI 06H 0.00 57 ONI 05H 0.00 61 SCI TSH

-0.04 73 ONI 08H 0.05 73 SCI TSH

-0.02 75 75 13 16 18 19 24 24 24 24 25 29 ONI 07H ONI 08H ONI 07H ONI 06H ONI 05H ONI 08H OSI 04H ONI 06H ONI 07H ONI 08H ONI 07H ONI 03H 0.00 0.00 0.00

-0.12

-0.07 0.00 0.14 0.00

-0.07 0.00 0.00 0.00 30 ONI 05H 0.00 30 ONI 06H 0.00 31 SAl 01H 27.14 33 ONI 06H 0.00 35 ONI 06H 0.00 37 ONI 04H 0.00 54 OSI 03H 0.10 0.24" Page 23 of 29 0.48 1.32 0.50 1.40 1.39 1.40 1.30 1.35 1.52 1.30 1.30 1.31 0.69 1.34 0.28 1.77 0.34 1.46 1.59 1.40 0.22 1.36 0.11 1.39 1.48 1.34 1.61 1.39 1.72 1.36 1.35 1.48 1.47 1.45 1.92 1.42 1.34 0.35 1.38 1.37 1.32 0.40 44 37 63 49 47 41 41 37 49 43 44 52 28 52 58 55 45 53 46 46 105 21 87 17 23 40 41 53 20 35 47 46 38 32 18 44 38 13 35 35 35 38 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pi Pl Pl Pl P2 Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl FROM TEH TEH TEH TO TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TSH TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEH TEC 01H 02H TEH TEC TEH TEC TEH TEH TEC TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND SAl LOC 03H INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN 29 54 0.11 0.34" 29 29 29 29 29 29 29 29 29 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 31 31 31 31 31 31 31 31 31 31 31 55 DNI 05H 0.00 57 SCI TSH

-0.04 62 DNI 02H 0.12 62 DNI 03H 0.00 63 DNI 05H 0.00 65 DSI 02H 0.00 67 DNI 03H 0.00 72 PCT AVl 0.17 18%

74 SAl TSH 0.02 0.13" 13 DNI 04H 0.00 19 DSI 02H 0.05 19 DNI 07H 0.00 20 DNI 08H 0.00 21 DNI 06H

-0.05 22 DSI 02H 0.12 27 28 32 SAl

. TSH DSI 03H SCI TSH

-0.03 0.10

-0.08 36 DNI 03H 0.00 38 DNI 06H

-0.05 40 DNI 04H 0.05 41 SCI TSH

-0.11 51 DNI 05H 0.00 54 DNI 06H 0.00 58 DSI 04H 0.00 59 SAl TSH 0.05 63 DSI 08H 0.10 63 SCI TSH 0.04 68 DSI 02H

-0.02 77 DNI 05H 0.00 14 DSI 04H 0.10 18 DSI 02H 0.02 18 DSI 03H 0.02 21 DNI 06H 0.00 22 DNI 06H 0.00 23 DNI 04H 0.14 23 DNI 06H 0.00 24 DNI 02H 0.00 34 DNI 04H 0.00 35 DNI 04H 0.00 35 DNI 07H 0.10 0.14" 0.17" Page 24 of 29 0.11 1.31 0.16 1.54 1.32 1.32 0.14 1.54 0.97 0.14 1.26 0.36 1.28 1.40 1.41 0.57 0.11 0.23 0.17 1.29 1.52 1.35 0.26 1.33 1.31 0.25 0.33 0.17 0.26 0.33 1.39 0.27 0.95 0.60 1.52 1.30 1.40 1.45 1.45 1.37 1.44 1.97 111 32 105 35 33 22 40 30 o

76 42 35 32 23 42 29 84 124 129 27 12 9

114 36 36 22 63 66 55 30 48 70 41 41 27 22 25 47 16 29 18 9

6 Pl P2 Pl Pl Pl Pl Pl P2 6

Pl Pl Pl Pl Pl Pl 6

Pl P2 Pl Pl Pl P2 Pl Pl Pl 6

Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM 03H TEH TSH TEH TEH TEH TEH TEH TEH TSH TEH TEH TEH TEH TEH TEH TSH TEH TSH TEH TEH TEH TO 03H TEC TSH TEC TEC TEC TEC TEC TEC TSH TEC TEC TEC TEC TEC TEC TSH TEC TSH TEC TEC TEC TSH TSH TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEe TEH TEe TEH TEe

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO DNI DNI LOC 05H 06H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN 31 39 31 42 0.00 31 31 31 31 31 31 32 32 32 32 32 32 32 32 32 33 44 54 68 68 69 72 17 22 27 DNI 06H DNI 04H PCT AV2 PCT AV3 PCT AV3 SAl TSH DNI 05H DSI 02H DSI 03H 0.00 0.00 0.00 19%

0.00 25%

0.00 18%

0.01 0.00 0.10 0.07 29 DNI 06H 0.05 32 SCI TSH

-0.03 36 DNI 04H 0.02 38 DSI 03H

-0.07 45 DSI 02H 0.05 51*

DSI 05H 0.07 18 DSI 02H 0.05 33 18 DSI 03H 0.02 33 21 DNI 04H 0.00 33 22 DNI 06H 0.00 33 22 DNI 07H 0.00 33 24 DNI 03H 0.00 33 24 DNI 04H 0.00 33 27 DNI 07H 0.00 33 28 DNI 07H 0.00 33 29 DNI 05H 0.00 33 40 DNI 05H 0.00 33 41 DNI 07H 0.00 33 42 DSI 05H 0.07 33 33 33 33 33 33 33 33 33 33 33 33 44 SCI TSH

-0.03 45 SCI TSH

-0.11 45 DSI 07H

-0.10 54 DSI 06H 0.00 57 DSI 04H 0.00 63 DNI 06H 0.00 64 DN I 06H

-0.05 66 DSI 02H 0.02 69 PCT AV2 0.00 20%

69 PCT AV3 0.00 20%

70 PCT AVl 0.00 22%

71 SCI TSH

-0.07 0.16" 2590 Page 25 of 29 1.50 1.30 1.35 1.30 1.04 1.68 0.82 0.17 1.42 0.62 0.42 1.41 0.29 1.44 0.18 0.50 0.36 0.23 0.40 1.67 1.34 1.29 1.58 1.77 1.35 1.29 1.54 1.26 1.33 0.31 0.21 0.26 0.39 0.29 0.40 1.45 1.42 0.49 0.96 1.02 1.71 0.32 36 37 29 36 o

o o

89 43 35 23 22 66 25 99 29 49 71 37 50 46 39 55 54 40 45 36 30 39 51 125 50 67 64 23 47 42 25 o

o o

91 Pl Pl Pl Pl P2 P2 P2 6

Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 P2 Pl Pl Pl Pl Pl Pl P2 P2 P2 P2 FROM TEH TEH TEH TEH TEH TEH TEH TSH TEH TEH TEH TEH TSH TEH TEH TEH TEH TEH TO TEC TEC TEC TEC TEC TEC TEC TSH TEC TEC TEC TEC TSH TEC TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TSH TSH TSH TEC TEC TEC TEC TEC TEC TEC TEC TEC TSH

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO PCT ONI LOC AVl 04H INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN 33 74 0.00 14%

34 26 ONI 02H ONI 04H ONI 04H ONI 04H PCT AV2 PCT AV3 PCT AV3 SCI TSH OSI 02H SCI TSH OSI 02H OSI 05H SCI TSH SAl TSH 0.02 0.07 0.02 0.00 0.00

-0.22 0.05 0.00

-0.13 0.00

-0.03 0.02 0.00 0.01 0.50 16%

18%

32%

34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 33 33 36 41 48 48 48 52 52 53 53 56 64 64 69 69 70 70 70 PCT AV2 0.00 24%

PCT AV3 0.00 36%

PCT AVl 0.00 11%

PCT AV2 0.00 16%

PCT AV3 0.00 22%

35 23 ONI 05H 0.00 35 24 ONI 03H 0.00 35 24 ONI 06H 0.00 35 28 ONI 04H 0.00 35 36 OSI 03H 0.00 35 38 ONI 03H 0.10 35 38 ONI 04H 0.00 35 38 ONI 06H 0.00 35 40 ONI 04H 0.00 35 45 OSI 02H 0.15 35 45 ONI 05H 0.00 35 45 ONI 06H 0.00 35 45 ONI 07H 0.00 35 47 MCI TSH

-0.06 35 65 ONI 08H 0.00 35 68 PCT AVl

-0.27 12%

35 70 PCT AV3 0.00 15%

35 72 PCT AVl 0.00 21%

35 72 PCT AV3 0.00 16%

36 23 ONI 06H 0.17 36 28 OSI 03H

-0.17 0.22" Page 26 of 29 0.91 0

P2 1.27 1.57 1.32 1.37 1.41 0.83 1.02 3.05 0.23 0.20 0.12 0.45 0.68 0.12 0.17 1.37 4.02 0.64 1.10 1.66 1.33 1.32 1.37 1.42 0.50 1.29 1.60 1.34 1.39 0.63 1.42 1.36 1.58 0.16 1.26 0.76 0.98 1.66 1.13 1.39 0.87 22 20 51 27 38 o

o o

86 61 110 45 19 122 75 o

o o

o o

37 36 42 54 34 28 48 37 35 19 39 34 30 122 20 o

o o

o 23 51 Pl Pl Pl Pl Pl P2 P2 P2 P2 Pl P2 Pl Pl P2 6

P2 P2 P2 P2 P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl P2 P2 P2 P2 Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TEH TSH TEH TSH TEH TEH TSH TSH TEH TEH TEH TEH TEH TO TEC TEC TEC TEC TEC TEC TEC TEC TEC TSH TEC TSH TEC TEC TSH TSH TEC TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO DSI DNI LOC 04H 06H INCH

%TW LENGTH 0.14 ANGLE VOLTS PHASE CHAN 36 28 36 28 0.00 36 28 DNI 07H 0.00 36 37 DNI 02H 0.00 36 37 DNI 03H 0.00 36 40 DNI 03H 0.02 36 44 DSI 03H

-0.02 36 48 SCI TSH

-0.03 36 62 SCI TSH 0.02 36 65 SCI TSH

-0.03 36 67 SCI TSH

-0.02 37 26 DNI 07H 0.00 37 34 SCI TSH

-0.13 37 36 DNI 04H 0.00 37 39 DSI 03H 0.02 37 42 DSI 03H 0.05 37 43 DNI 03H 0.00 37 43 DNI 06H 0.00 37 53 DNI 06H 0.00 37 53 DNI 07H 0.00 37 54 DSI 05H 0.07 37 56 DSI 03H

-0.05 37 56 DNI 04H 0.00 37 63 DNI 06H 0.05 38 26 DNI 05H 0.17 38 37 DNI 03H 0.00 38 37 DNI 04H 0.02 38 40 DSI 05H 0.00 38 41 DNI 06H 0.00 38 44 DSI 02H 0.00 38 45 DNI 02H 0.00 38 48 DNI 03H 0.00 38 52 DNI 03H 0.00 38 52 DNI 05H 0.00 38 52 DNI 06H 0.00 38 52 DNI 07H 0.00 38 38 38 39 39 39 55 DNI 03H 0.00 72 PCT AVl 0.00 17%

72 PCT AV2 0.00 13%

23 DSI 02H 0.00 31 DNI 04H 0.00 38 DNI 07H 0.00 Page 27 of 29 0.21 1.36 1.31 1.91 1.33 1.25 0.64 0.09 0.17 0.11 0.30 1.56 0.13 1.31 0.43 0.63 1.44 1.25 1.35 1.33 0.24 0.69 1.57 1.29 1.87 1.57 1.90 0.47 1.27 0.92 1.33 1.71 1.66 1.25 1.29 2.03 1.42 1.21 0.83 1.35 1.43 1.36 34 51 40 10 40 45 56 72 59 119 133 16 78 46 49 40 28 20 22 26 55 39 51 40 17 29 30 107 16 21 54 16 35 30 24 21 49 o

o 9

17 29 Pl Pl Pl Pl Pl Pl Pl P2 P2 P2 P2 Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 P2 Pl Pl Pl FROM TEH TEH TO TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TSH TSH TSH TSH TSH TSH TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN 39 38 PCT AV3

-0.02 16%

39 39 ONI 04H 0.00 39 39 ONI 05H 0.00 39 39 ONI 07H 0.00 39 39 ONI 08H 0.00 39 42 OSI 02H 0.05 39 46 DSI 02H 0.05 39 51 DNI 05H 0.00 39 51 DNI 06H 0.00 39 53 DNI 07H 0.00 DNI 02H 0.00 SCI TSH 0.06 DSI 03H 0.10 39 39 39 39 40 40 40 40 40 40 40 40 40 40 40 40 41 41 41 41 41 41 41 41 41 42 42 42 42 42 43 43 54 55 57 68 31 33 PCT AVl 0.00 15%

DNI 08H 0.00 DNI 08H 0.10 36 DNI 03H 0.00 36 DNI 04H 0.00 37 DSI 03H 0.07 50 SCI TSH

-0.10 54 DNI 04H 0.15 56 DNI 07H 0.00 66 69 69 69 28 32 33 33 43 46 53 55 68 30 43 54 54 PCT AVl PCT AV2 PCT AV3 PCT AV4 DNI 08H DNI 05H DNI 05H DNI 06H SCI TSH SCI TSH DNI 03H DNI 08H PCT AVl DNI 08H SCI TSH PSI 01C PSI 01H

-0.36 0.00 0.00 0.00 0.00 0.00 0.19 0.00

-0.03

-0.08 0.00 0.00

-0.03

-0.05

-0.03

-0.07 0.07 64 DSI 04H 0.05 34 DNI 05H 0.00 36 DNI 08H 0.00 14%

18%

23%

18%

12%

Page 28 of 29 1.03 1.50 1.31 1.43 1.32 0.44 0.36 1.26 1.35 1.51 1.30 0.10 0.39 0.99 1.27 1.43 1.26 1.37 0.79 0.10 1.66 1.41 0.91 0.82 1.27 0.83 1.46 1.58 1.68 1.27 0.18 0.26 1.62 1.31 0.18 1.90 0.22 5.26 5.43 0.45 1.20 1.25 o

46 47 35 35 46 120 49 29 34 17 95 50 o

19 27 51 53 50 126 39 31 o

o o

o 24 18 17 19 67 89 44 26 o

17 105 56 42 43 31 15 P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl P2 Pl Pl Pl Pl Pl P2 Pl Pl P2 P2 P2 P2 Pl Pl Pl Pl P2 P2 Pl Pl 2

Pl P2 8

8 Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TSH TEH TEH TEH TEH TO TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TSH TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TSH TSH TEH TEH 08H TEH TSH TEH TEH TEH TEH TEH TSH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TSH TSH TEC TEC AVl TEC TSH TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21A (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 43 42 PCT AVl 0.00 19%

1.40 0

P2 TEH TEC 43 43 SCI TSH

-0.01 44° 0.19 108 P2 TSH TSH 43 44 ONI 03H 0.00 1.54 37 Pl TEH TEC 43 44 ONI 04H 0.00 1.43 23 Pl TEH TEC 43 45 ONI 04H 0.00 1.50 17 Pl TEH TEC 43 48 ONI 04H 0.00 1.50 24 Pl TEH TEC 43 54 PSI 01C

-0.17 5.44 50 8

TEH TEC 43 54 ONI 04H 0.00 1.73 20 Pl TEH TEC 43 57 PCT AVl 0.00 15%

0.97 0

P2 TEH TEC 44 35 OSI 03H

-0.05 0.57 26 Pl TEH TEC 44 42 PCT AVl 0.00 15%

1.04 0

P2 TEH TEC 44 42 PCT AV2 0.00 20%

1.58 0

P2 TEH TEC 44 48 PCT AVl 0.00 12%

0.59 0

P2 TEH TEC 44 48 PCT AV2 0.00 12%

0.59 0

P2 TEH TEC 44 50 ONI 03H

-0.07 1.64 19 Pl TEH TEC 44 55 PCT AV4 0.00 25%

1.83 0

P2 TEH TEC 44 55 PCT AV3 0.00*

13%

0.19 0

2

  • 08H AV3 44 58 OSI 06H 0.00 0.23 20 Pl TEH TEC 45 40 PCT AVl 0.00 29%

2.51 0

P2 TEH TEC 45 55 PSI 01C 0.15 5.43 216 8

TEH TEC 46 52 OSI 06H 0.10 0.71 30 Pl TEH TEC Page 29 of 29

Attachment B BEAVER VALLEY UNIT #2 2R16 SG EXAMINATION RESULTS 2RCS-SG21B TUBES WITH SERVICE INDUCED INDICATIONS

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 1

1 1

1 1

1 1

2 2

2 2

2 2

2 2

2 2

2 2

2 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 43 OSI 02H

-0.04 46 ONI 04H 0.00 51 SCI TSH

-0.14 52 OSI 02H

-0.04 56 OSI 02H 0.04 57 OSI 04H 0.00 64 ONI 04H 0.00 7

ONI 04H 0.00 9

ONI 07H 0.00 24 OSI 02H 0.00 28 OSI 02H

-0.01 54 OSI 04H 0.00 62 OSI 03H

-0.03 63 OSI 04H 0.00 67 OSI 06H 0.01 70 OSI 05H 0.21 73 DSI 03H

-0.03 73 OSI 04H 0.03 88 SCI TSH

-0.11 94 OSI 04H 0.03 32 OSI 03H

-0.06 42 ONI 06H 0.00 48 SCI TSH 0.00 48 ONI 02H 0.00 48 ONI 04H 0.00 48 OSI 05H 0.00 48 ONI 07H 0.00 53 ONI 04H 0.00 54 OSI 02H 0.00 55 OSI 02H

-0.18 60 OSI 02H 0.00 60 OSI 03H

-0.03 61 ONI 02H 0.00 61 ONI 04H 0.00 61 ONI 05H 0.03 61 OSI 06H 0.00 61 ONI 08H 0.00 63 OSI 02H 0.00 63 OSI 03H

-0.06 72 OSI 03H

-0.03 78 ONI 07H 0.00 88 OSI 04H

-0.04 Page 1 of 16 0.53 1.59 0.21 0.33 0.46 0.69 1.39 1.51 1.59 0.31 0.70 0.20 0.67 0.67 0.28 0.82 0.17 0.22 0.11 0.53 0.43 1.07 0.33 1.60 1.74 1.40 1.32 1.72 0.49 0.51 0.57 0.68 1.62 1.51 1.38 0.34 1.61 0.80 0.52 0.62 1.33 0.26 105 29 116 53 48 28 45 55 50 71 44 50 49 26 60 70 93 33 70 42 102 23 86 55 49 47 43 53 123 126 72 65 35 44 24 53 25 52 59 23 50 64 Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 08H 08H TSH 08H TEH TEH TSH TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH TSH TSH 08H TEH 08H TEH 08H TEH TSH TSH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO OSI OSI OSI OSI LOC 04H 02H 06H 03H INCH

%TW LENGTH

-0.10 ANGLE VOLTS PHASE CHAN 3

89 4

23 0.04 4

23

-0.04 4

32 0.00 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 37 SCI TSH

-0.05 41 OSI 04H 0.00 43 OSI 02H 0.00 44 OSI 02H

-0.09 48 OSI 03H 0.00 52 OSI 03H 0.00 54 OSI 02H 0.00 56 OSI 04H

-0.07 57 OSI 02H 0.07 57 OSI 04H

-0.01 58 OSI 02H 0.00 59 OSI 02H

-0.03 59 OSI 03H 0.06 63 OSI 04H

-0.07 66 MCI TSH

-0.11 75 ONI 05H 0.01 12 OSI 03H 0.07 14 OSI 03H 0.05 20 OSI 03H 0.05 22 OSI 04H 0.07 22 ONI 05H

-0.02 28 OSI 02H 0.02 47 SCI TSH

-0.14 52 OSI 02H 0.07 54 OSI 02H 0.19 54 OSI 03H

-0.02 54 ONI 08H

-0.05 56 OSI 03H 0.02 58 OSI 02H 0.12 59 ONI 07H 0.02 60 OSI 02H

-0.02 63 OSI 04H 0.07 64 OSI 02H 0.07 64 OSI 03H 0.02 68 OSI 02H 0.05 73 OSI 02H 0.00 75 OSI 04H 0.12 81 OSI 05H 0.02 Page 2 of 16 0.55 34 P1 0.22 0.24 0.15 0.15 0.36 0.29 0.24 0.50 0.52 0.43 0.32 0.59 0.19 0.43 0.26 0.34 0.59 0.16 1.34 0.39 0.63 0.37 0.48 1.50 0.56 0.23 0.43 0.39 0.55 0.87 0.96 0.23 1.30 0.35 0.13 0.17 0.42 0.55 0.37 0.22 0.38 131 138 116 58 49 27 86 67 50 107 156 102 91 106 65 47 20 136 56 54 66 107 42 43 70 95 51 104 37 34 19 94 40 118 114 37 31 39 44 65 25 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 FROM 08H 08H 08H 08H TO TEH TEH TEH TEH TSH TSH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH TSH TSH 08H TEH TEH TEC TEH TEC TEH TEH TEC TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO ONI OSI OSI OSI OSI LOC 08H 02H 03H 03H 04H INCH

%TW LENGTH 0.05 ANGLE VOLTS PHASE CHAN 5

82 5

92 0.05 5

93 0.00 6

16 0.10 6

23 0.05 6

6 6

6 6

6 6

6 6

6 6

6 7

7 7

7 7

7 7

7 7

7 7

8 8

8 8

8 8

8 8

8 8

8 8

8 8

26 OSI 02H 0.02 27 OSI 03H 0.10 27 SAl 03H 0.21 28 SCI TSH

-0.08 44 SAl TSH 0.96 52 OSI 02H

-0.05 53 OSI 02H 0.00 53 OSI 03H

-0.02 58 OSI 02H 0.05 61 OSI 08H 0.05 63 OSI 02H 0.05 88 SCI TSH

-0.06 30 ONI 05H 0.00 31 ONI 04H 0.00 52 OSI 02H 0.07 52 ONI 05H 0.07 54 OSI 02H

-0.05 56 OSI 02H 0.14 63 OSI 07H 0.02 64 ONI 04H 0.05 69 PSI 06C 0.00 70 ONI 04H 0.02 75 OSI 02H 0.00 2

OSI 03H 0.05 3

ONI 05H 0.00 4

ONI 05H 0.02 9

OSI 02H 0.05 9

OSI 03H 0.02 18 OSI 02H

-0.19 18 OSI 03H 0.02 20 OSI 02H 0.05 22 OSI 02H

-0.02 37 OSI 03H 0.14 53 OSI 02H 0.02 56 OSI 03H 0.00 59 OSI 02H 0.14 63 ONI 04H 0.00 0.21" 0.24" Page 3 of 16 1.30 0.45 0.48 0.32 0.28 0.41 0.37 0.11 0.15 0.21 0.20 0.52 0.23 0.59 0.32 0.23 0.16 1.35 1.30 0.72 1.26 0.18 0.50 0.42 0.69 9.22 0.72 0.40 0.64 1.39 1.60 0.32 0.25 0.53 0.32 0.30 0.28 0.39 0.79 0.46 0.27 1.31 55 55 50 45 96 36 48 65 88 82 105 24 49 72 57 53 68 50 19 59 48 47 104 32 30 344 34 18 31 45 55 98 120 91 75 131 139 20 76 61 80 55 Pl Pl Pl Pl Pl Pl Pl 6

P2 6

Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl 8

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TO TEC TEC TEC TEC TEC TEH TEC TEH TEC 03H 03H TSH TSH TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL 9

4 INO OSI SAl OSI lOC 03H 03H 03H INCH

%TW LENGTH 0.05 ANGLE VOLTS PHASE CHAN 9

4 0.00 0.31" 9

5 0.05 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

10 10 10 10 10 10 10 10 10 10 10 10 8

OSI 03H 0.07 8

ONI 06H

-0.02 11 OSI 02H

-0.02 11 OSI 03H 0.07 16 OSI 03H 0.02 17 OSI 02H 0.02 17 OSI 03H 0.07 18 OSI 02H

-0.07 18 OSI 03H 0.02 26 OSI 02H 0.02 26 OSI 03H 0.10 27 SCI TSH

-0.11 51 ONI 02H

-0.05 52 OSI 02H 0.05 52 OSI 03H 0.14 59 OSI 03H 0.10 59 OSI 05H 0.10 64 ONI 03H 0.00 64 OSI 04H 0.05 64 SAl 04H

-0.06 75 ONI 03H 0.02 80 OSI 02H 0.00 80 ONI 07H 0.12 85 OSI 02H 0.07 92 OSI 02H 0.10 92 ONI 04H 0.22 93 OSI 02H 0.07 6

OSI 02H

-0.05 10 OSI 02H 0.02 13 SCI TSH

-0.11 14 OSI 02H 0.02 15 OSI 02H 0.00 17 OSI 02H 0.05 18 OSI 02H

-0.02 24 ONI 06H 0.00 26 OSI 02H 0.02 37 OSI 03H 0.05 41 OSI 07H 0.00 50 OSI 02H 0.12 0.21" Page 4 of 16 0.38 0.08 0.24 0.24 1.43 0.34 0.59 0.47 0.59 0.19 0.22 0.64 0.42 0.79 0.11 1.27 0.32 0.42 0.45 0.32 1.51 0.89 0.15 1.25 0.65 1.29 0.80 1.05 1.36 0.27 0.16 0.23 0.16 0.44 0.32 0.47 0.71 1.26 0.48 0.29 0.19 0.32 87 112 98 74 54 90 46 108 84 55 63 29 60 56 61 43 32 40 21 61 40 19 58 36 56 51 38 123 30 88 83 22 121 61 56 94 54 45 16 149 60 88 Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH 03H TEH TO TEC 03H TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEH TEH TEH TEH TEH 04H TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC 04H TEC TEC TEC TEC TEC TEC TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL 10 52 IND DSI OSI LaC 02H 04H INCH

%TW LENGTH 0.00 10 52 0.00 10 53 OSI 02H 0.02 10 54 OSI 02H 0.05 10 56 OSI 02H

-0.05 10 58 OSI 05H 0.02 10 63 OSI 02H 0.00 10 71 OSI 05H 0.12 10 75 ONI 02H 0.00 10 78 OSI 04H 0.02 10 89 OSI 02H 0.05 11 8

OSI 03H 0.14 11 9

OSI 06H 0.02 11 9

OSI 07H 0.15 11 10 ONI 06H 0.00 11 18 OSI 02H

-0.02 11 20 OSI 02H 0.00 11 11 11 11 11 11 11 11 11 11 21 OSI 03H 0.12 25 OSI 03H 0.10 25 SAl 03H 0.16 35 OSI 02H 0.02 40 NQI 04C 3.44 42 OSI 03H 0.07 53 OSI 02H 0.00 53 ONI 06H 0.00 57 OSI 03H 0.02 58 OSI 03H 0.12 11 58 ONI 06H 0.05 11 61 OSI 02H 0.02 11 61 OSI 03H 0.14 11 61 ONI 07H 0.00 11 64 ONI 06H 0.00 11 64 ONI 07H 0.00 11 66 ONI 05H 0.00 11 71 ONI 06H 0.19 11 71 ONI 07H 0.15 11 74 ONI 02H 0.02 11 75 OSI 02H

-0.02 11 75 ONI 07H

-0.02 11 78 ONI 06H 0.02 11 83 OSI 03H 0.17 11 83 OSI 04H 0.12 0.26" ANGLE Page 5 of 16 VOLTS PHASE 1.15 105 0.36 58 0.46 0.27 0.42 0.24 0.26 0.40 1.30 0.41 0.48 0.42 0.35 0.36 1.44 0.57 0.54 0.34 0.42 0.11 0.16 0.22 0.17 0.43 1.38 0.28 0.23 1.33 1.42 0.42 1.41 1.31 1.32 1.54 1.56 1.33 1.22 0.99 1.32 1.56 0.70 0.69 75 33 113 62 39 45 40 20 58 139 27 30 31 92 96 56 45 57 38 94 56 72 66 55 70 49 37 83 52 53 47 51 52 56 35 44 55 46 43 34 CHAN Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl 3

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TO TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH 03H TEH TEH TEH TEH TEH TEH TEH TEC TEC 03H TEC TEC TEC TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO DNI LOC 08H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN FROM TO TEC TEC 01C 01C 11 83 85 DNI 06H 0.00 11 11 11 12 12 12 12 12 12 12 12 12 12 12 12 12 12 91 PCT 01C

-0.29 10%

0.18" 91 VOL 01C

-0.29 0.15" 9

DNI 04H 0.00 10 DSI 02H

-0.02 11 DNI 06H 0.00 15 DSI 02H 0.05 15 DSI 03H 0.05 16 DSI 03H 0.00 22 DSI 02H 0.07 24 DSI 02H 0.00 24 DSI 04H 0.07 51 DSI 02H 0.00 52 DSI 02H 0.14 52 DSI 03H

. -0.05 61 DSI 03H 0.10 69 DNI 02H 0.14 12 69 DNI 04H 0.00 13 16 DSI 02H 0.00 13 16 DSI 03H 0.07 13 16 DNI 06H 0.00 13 37 DSI 03H 0.09 13 39 DSI 07H 0.00 13 47 DSI 02H 0.07 13 47 SAl 02H

-0.04 13 53 DSI 02H

-0.02 13 56 DSI 03H 0.00 13 66 DNI 05H 0.00 13 73 DSI 02H 0.02 13 77 DSI 03H 0.00 13 77 DNI 06H 0.00 13 77 SCI TSH

-0.04 13 78 DSI 02H 0.02 13 85 DSI 02H 0.07 13 86 DSI 02H 0.02 13 91 DSI 02H

-0.05 14 8

DSI 03H 0.02 14 13 DSI 02H 0.02 14 15 DSI 03H 0.00 14 14 25 DSI 02H 0.00 27 DSI 03H 0.07 0.37" Page 6 of 16 1.29 47 Pl TEH 1.46 0.06 0.12 1.44 0.39 1.39 0.41 0.58 0.34 0.49 0.54 0.32 0.18 0.58 0.70 0.96 1.30 1.39 0.75 0.25 1.28 0.35 0.37 0.23 0.17 0.39 0.73 1.31 0.34 0.78 1.40 0.16 0.24 0.35 0.19 0.55 0.24 0.59 0.39 0.52 0.28 46 o

108 51 70 41 98 77 149 134 109 78 82 74 44 23 16 28 110 68 55 62 57 42 112 36 97 38 109 32 52 59 50 59 71 98 103 35 53 80 57 Pl 3

6 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH 01C 01C TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEH TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND OSI OSI OSI OSI LOC 05H 02H 06H 03H INCH

%TW LENGTH 0.07 ANGLE VOLTS PHASE CHAN 14 28 14 32 0.07 14 35 0.00 14 36 0.14 14 36 ONI 07H 30.95 14 39 OSI 02H 0.12 14 54 OSI 02H 0.07 14 54 OSI 03H

-0.02 14 57 OSI 02H 0.00 14 57 OSI 03H 0.00 14 61 OSI 02H 0.00 14 61 OSI 03H 0.10 14 61 OSI 05H 0.07 14 63 OSI 03H 0.12 14 66 ONI 05H 0.00 14 14 14 14 66 ONI* 08H 0.00 70 OSI*

02H 0.05 83 NQI 07H 19.39 83 SCI TSH

-0.08 14 84 OSI 04H 0.02 14 88 OSI 02H 0.00 15 12 OSI 03H 0.12 15 26 OSI 03H 0.02 15 27 OSI 02H 0.05 15 36 OSI 02H 0.00 15 36 ONI 03H 0.00 15 51 OSI 02H 0.12 15 51 SAl 02H 0.07 15 52 OSI 02H 0.05 15 60 ONI 03H 0.05 15 60 ONI 05H

-0.07 15 60 ONI 06H 0.05 15 60 ONI 08H 0.14 15 65 ONI 04H 0.00 15 71 OSI 05H

-0.05 15 15 15 15 15 16 16 75 OSI 02H 0.02 75 OSI 04H 0.12 75 SCI TSH

-0.15 80 OSI 04H 0.07 87 OSI 02H 0.12 26 ONI 07H 0.00 26 ONI 08H 0.00 0.27" Page 7 of 16 0.28 0.38 0.26 0.59 0.51 0.33 0.60 0.40 0.79 0.47 0.36 0.75 0.57 0.38 0.98 1.30 0.55 1.18 0.14 0.21 0.32 0.17 0.36 0.23 0.23 1.67 0.36 0.25 0.71 1.02 0.63 1.70 0.31 1.27 0.56 0.13 0.09 0.12 0.29 0.33 1.42 1.30 46 118 108 113 155 156 30 37 49 53 104 30 35 44 21 34 100 120 70 57 32 82 123 34 37 35 99 71 56 35 90 35 39 47 28 47 41 80 159 111 37 34 Pl Pl Pl Pl 5

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 3

P2 Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl FROM TEH TEH TEH TEH TO TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEH TSH TEC TEC TEC TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TSH TEH TEH TEH TEH TEC TEC TSH TEC TEC TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO OSI LOC 03H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC TEC TEC TEC 04H TSH TEC TEC TEC TEC TEC TEC TEC TEC 16 27 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 30 PCT AV2

-0.02 10%

30 PCT AV3 0.24 10%

31 OSI 02H 0.21 37 OSI 02H 0.10 37 OSI 04H 0.00 37 SAl 04H 0.00 41 SCI TSH

-0.09 42 ONI 06H 0.00 44 OSI 02H 0.05 55 OSI 05H 0.05 55 ONI 06H 0.24 61 OSI 02H 0.07 62 ONI 07H 0.00 69 ONI 05H 0.00 71 OSI 02H 0.12 17 33 OSI 02H 0.14 17 33 OSI 03H 0.02 17 33 SAl 03H

-0.05 17 35 OSI 03H 0.05 17 37 SCI TSH

-0.07 17 42 OSI 03H 0.05 17 44 OSI 02H 0.02 17 44 SAl 02H 0.06 17 44 SAl 02H

-0.23 17 17 17 17 17 17 17 17 17 17 17 17 18 18 18 18 18 62 ONI 02H 0.00 62 ONI 06H 0.00 62 MCI TSH

-0.05 64 OSI 02H 0.05 68 OSI 02H 0.05 68 OSI 03H 0.10 68 OSI 04H

-0.02 68 ONI 05H 0.24 68 ONI 07H 0.00 68 SAl 04H 0.21 77 ONI 08H 0.05 84 ONI 04H 0.00 12 OSI 03H 0.02 18 OSI 02H

-0.02 21 ONI 05H

-0.02 28 ONI 03H 0.00 28 OSI 04H 0.00 0.24" 0.34" 0.08" 0.16" 0.21" Page 8 of 16 0.38 34 P1 TEH 0.53 0.52 0.32 0.41 0.25 0.14 0.27 1.32 0.37 0.32 1.39 0.55 1.34 1.36 0.19 0.52 0.55 0.23 0.54 0.17 0.46 0.51 0.06 0.12 1.78 1.26 0.16 0.17 0.51 0.71 1.09 1.30 1.25 0.14 1.29 1.71 0.21 0.44 1.53 1.40 0.34 o

o 48 33 88 89 111 38 12 105 36 32 25 55 122 122 96 84 49 115 45 42 95 102 20 33 59 81 107 27 14 31 43 76 47 54 36 51 22 53 150 P2 P2 P1 P1 P1 6

P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 6

P1 P2 P1 P1 6

6 P1 P1 P2 P1 P1 P1 P1 P1 P1 6

P1 P1 P1 P1 P1 P1 P1 TEH TEH TEH TEH TEH 04H TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEH TEC 03H 03H TEH TEC TSH TSH TEH TEC TEH TEC 02H 02H 02H 02H TEH TEH TSH TEH TEH TEC TEC TSH TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC 04H 04H TEH TEC TEH TEC TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 18 29 DSI 02H 0.00 18 30 DSI 04H 0.02 18 36 DSI 03H

-0.07 18 36 DNI 05H 0.00 18 36 DNI 08H 0.00 18 37 DSI 03H

-0.07 18 38 DSI 03H

-0.07 18 42 DSI 02H 0.02 18 53 DSI 03H 0.10 18 53 DSI 04H 0.12 18 57 DSI 03H 0.10 1858 DSI 02H

-0.07 18 61 DSI 03H 0.10 18 64 DSI 03H 0.05 18 65 DNI 07H 0.00 18 69 DSI 05H 0.02 18 70 DNI 02H 0.07 18 70 DNI 07H 0.02 18 74 DNI 05H 0.02 18 76 DSI 03H 0.02 19 15 DSI 02H 0.07 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 15 DSI 04H 0.10 21 SAl TSH 0.03 23 SAl TSH 0.03 29 DSI 02H 0.00 29 DSI 03H 0.10 36 DSI 02H 0.05 36 DNI 05H 0.10 39 DSI 03H 0.02 39 DSI 04H 0.02 39 DNI 07H 0.22 45 DSI 02H 0.05 45 DNI 07H 0.02 50 DSI 03H 0.17 50 DNI 05H 0.05 51 DSI 02H 0.05 51 DSI 03H 0.07 52 DNI 06H

-0.05 71 DSI 05H 0.00 72 DNI 06H 0.00 74 DSI 02H 0.00 75 Mel TSH

-0.07 0.19" 0.19" Page 9 of 16 0.60 0.24 1.04 1.27 1.26 0.37 0.29 0.26 0.53 0.34 0.21 0.64 0.41 0.43 1.32 0.54 1.34 1.49 1.27 0.75 0.30 0.30 0.40 0.27 1.09 0.97 0.94 1.75 0.85 0.49 0.99 0.43 1.26 0.68 1.36 0.64 0.56 1.29 0.42 1.36 0.29 0.12 61 72 41 47 43 54 88 104 49 57 90 114 12 72 48 13 15 25 54 28 56 23 49 72 80 47 61 32 39 61 31 86 44 45 48 91 49 56 25 55 13 59 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

6 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TSH TSH TEH TEH TEH TEH TEH TEe TSH TSH TEe TEe TEe TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEH TSH TEe TEe TSH

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 19 19 19 19 19 19 19 20 20 20 20 20 20 20 20 76 DSI 02H 0.12 78 DSI 02H

-0.05 83 PCT TSC 1.41 10%

83 VOL TSC 1.41 83 PCT TSC 0.39 12%

83 VOL TSC 0.40 85 DSI 02H 0.07 11 DSI 02H 0.02 11 DNI 05H 0.07 11 DNI 07H 0.00 16 DSI 03H 0.02 19 DSI 04H 0.00 23 DSI 02H 0.05 23 SAl 02H

-0.05 53 SCI TSH

-0.08 20 70 DSI 02H

-0.02 20 81 DSI 02H 0.12 20 89 DSI 02H

-0.02 21 23 DNI 07H

-0.02 21 45 DSI 04H

-0.07 21 49 DNI 03H 0.00 21 53 DSI 03H 0.24 21 53 DSI 05H 0.10 21 54 DSI 02H

-0.05 21 75 DSI 02H 0.12 22 12 DSI 03H 0.05 22 36 DSI 03H 0.05 22 52 DSI 02H 0.00 22 52 DSI 03H

-0.05 22 53 DSI 02H 0.05 22 62 DSI 03H 0.05 22 64 DSI 02H

-0.07 23 33 DSI 03H 0.12 23 37 DNI 02H 0.02 23 37 DNI 04H 0.00 23 56 DSI 02H 0.02 23 61 DSI 02H 0.07 23 63 DSI 03H

-0.02 23 68 DNI 06H

-0.12 23 86 DSI 02H

-0.05 24 29 DSI 05H 0.00 24 30 DSI 03H 0.10 0.28" 0.34" 0.24" 0.27" 0.26" Page 10 of 16 0.34 0.33 0.06 0.08 0.07 0.09 0.27 0.83 1.29 1.40 0.40 0.66 0.19 0.12 0.25 0.36 0.40 0.35 1.31 0.28 1.31 0.97 0.28 1.36 0.13 0.14 0.28 0.25 0.35 0.21 0.77 0.39 0.41 1.31 1.37 0.48 0.38 0.22 0.90 0.23 0.26 0.26 43 69 o

77 o

74 94 20 22 19 42 10 76 64 46 37 133 73 21 128 52 48 93 50 97 24 44 41 101 87 31 131 27 21 20 150 26 45 46 47 14 109 Pl Pl 3

6 3

6 Pl Pl Pl Pl Pl Pl Pl 6

P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEH TSC TSC TSC TSC TEH TEH TEH TEH TEH TEH TEH 02H TSH TEC TEC TSC TSC TSC TSC TEC TEC TEC TEC TEC TEC TEC 02H TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO OSI OSI OSI LOC 03H 02H 08H INCH

%TW LENGTH 0.10 ANGLE VOLTS PHASE CHAN 24 32 24 42 0.00 24 51 0.05 24 24 24 24 24 24 24 24 25 25 25 52 OSI 02H 0.05 56 OSI 02H 0.00 58 OSI 03H 0.05 62 OSI 03H 0.07 63 OSI 03H 0.12 68 OSI 08H 0.07 71 OSI 05H 0.07 84 OSI 05H

-0.02 17 OSI 02H 0.07 18 ONI 06H 0.00 23 PCT AV3 0.00 14%

25 29 OSI 02H 0.10 25 63 ONI 06H

-0.02 25 64 OSI 06H 0.05 25 79 ONI 03H 0.00 25 79 OSI 08H 0.02 26 16 ONI 02H 0.00 26 20 ONI 06H 0.02 26 30 OSI 03H 0.05 26 39 OSI 03H 0.00 26 40 PSI 06C 0.00 26 78 OSI 02H 0.05 27 17 ONI 03H 0.00 27 17 ONI 07H 0.00 27 46 OSI 06H 0.12 27 53 OSI 03H 0.07 27 68 OSI 02H 0.14 28 28 28 28 28 28 28 29 29 29 29 29 38 ONI 05H 0.00 41 OSI 02H 0.05 60 ONI 04H 0.05 63 OSI 03H 0.02 70 PCT AV3 0.00 26%

70 PCT AV4 0.00 22%

81 OSI 02H 0.02 20 OSI 03H 0.07 20 ONI 05H 0.00 27 OSI 03H 0.07 31 OSI 05H

-0.02 32 OSI 03H 0.07 Page 11 of 16 0.27 57 Pl 0.67 36 Pl 0.29 0.52 0.40 0.51 0.64 0.70 0.31 0.38 0.29 0.26 1.34 1.00 0.22 1.25 0.45 1.26 0.46 1.36 1.37 0.63 0.17 9.17 0.33 1.26 1.37 0.22 0.28 0.38 1.27 0.43 1.50 0.54 2.11 1.52 0.42 0.72 1.37 0.56 0.38 0.23 40 53 77 52 40 21 34 44 129 37 25 o

63 20 26 51 131 37 27 58 65 165 42 22 28 34 24 40 21 30 29 31 o

o 48 40 45 65 96 51 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl 8

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 P2 Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TO TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH*

TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO OSI LOC 05H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN FROM TO TEe TEe TEe 06H TEe TEe TEe 02H 29 32 29 29 29 29 29 29 29 34 OSI 03H 0.12 35 OSI 04H 0.10 35 SAl 04H 0.03 37 OSI 03H 0.02 38 OSI 02H 0.00 38 ONI 07H 0.00 38 MAl 02H

-0.07 29 40 OSI 03H 0.00 29 41 OSI 02H 0.00 29 48 ONI 02H 0.07 29 56 OSI 02H 0.14 29 56 ONI 04H 0.02 30 16 OSI 04H 0.07 30 20 OSI 04H 0.00 30 21 ONI 06H 0.00 30 24 ONI 06H 0.00 30 27 OSI 02H 0.02 30 32 OSI 03H 0.05 30 41 ONI 02H 0.00 30 48 ONI 04H

-0.02 30 30 50 OSI 04H 0.07 53 peT AV3 0.07 16%

30 56 ONI 04H 0.00 30 78 OSI 02H 0.00 30 78 OSI 04H 0.00 30 79 OSI 02H

-0.10 30 81 OSI 03H 0.05 31 22 ONI 06H 0.00 31 23 OSI 02H 0.17 31 31 ONI 05H 0.12 31 32 ONI 02H

-0.05 31 32 OSI 03H 0.00 31 32 OSI 05H

-0.07 31 37 OSI 03H 0.00 31 39 OSI 02H 0.07 31 39 OSI 03H 0.17 31 31 31 31 31 41 peT AVl 0.00 11%

41 peT AV2 0.00 12%

41 peT AV3

-0.07 17%

49 ONI 03H 0.00 52 OSI 02H 0.00 0.25" 0.28" Page 12 of 16 0.67 58 Pl TEH 0.48 0.46 0.13 0.80 0.52 1.31 0.11 0.95 0.56 1.66 1.01 1.44 0.23 0.26 1.31 1.27 0.54 0.27 1.29 1.42 0.60 1.08 1.37 0.72 0.42 0.11 0.28 1.28 0.77 1.32 1.44 0.78 0.32 0.53 0.38 0.39 0.67 0.76 1.23 1.51 0.51 48 26 116 23 43 48 124 43 17 13 79 38 45 50 52 40 21 40 29 32 32 o

26 19 27 45 29 50 58 38 38 40 107 60 40 38 o

o o

26 28 Pl Pl 6

Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 P2 P2 Pl Pl TEH TEH 04H TEH TEH TEH 02H TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEH TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEH TEH TEH TEH TEe TEe TEe TEe TEe

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW coi.

IND SCI LOC TSH INCH

%TW LENGTH

-0.04 ANGLE 103 0

VOLTS PHASE CHAN 31 55 31 31 31 31 31 31 31 31 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 59 PCT AV2 0.00 12%

59 PCT AV3 0.00 25%

59 PCT AV4 0.00 16%

71 OSI 05H 0.10 75 ONI 03H 0.17 76 OSI 02H 0.19 78 OSI 02H

-0.10 78 OSI 03H 0.24 29 OSI 05H 0.05 31 SAl 02H 0.23 33 ONI 02H

-0.07 33 ONI 03H 0.00 35 ONI 02H 0.00 50 PCT AV2 0.00 26%

50 PCT AV3 0.00 13%

53 OSI* 02H 0.07 55 55 55 55 57 57 59 61 77 31 32 37 40 40 41 41 41 41 OSI 02H OSI 05H PCT AV3 PCT AV4 PCT AVl PCT AV3 PCT AV3 OSI 02H OSI 02H OSI 07H OSI 02H OSI 04H PCT AV2 PCT AV3 PSI 06C PCT AVl PCT AV2 PCT AV3 0.00

-0.02 0.00 0.00 0.00 0.00 0.10 0.10

-0.02 0.07 0.00 0.10

-0.17 0.19 0.00 0.00

-0.26 0.00 44 OSI 02H

-0.05 50 MCI TSH

-0.08 29%

20%

17%

14%

27%

18%

18%

13%

28%

16%

55 PCT AV2 0.02 13%

57 PCT AVl 0.00 15%

57 PCT AV2 0.00 17%

62 OSI 02H 0.05 63 PCT AV2

-0.10 31%

0.21" Page 13 of 16 0.31 0.72 2.04 1.01 0.26 1.31 0.48 0.40 1.16 0.22 0.08 1.40 1.39 1.36 2.23 0.86 0.84 0.80 0.24 2.84 1.55 1.11 0.88 2.35 0.41 0.57 0.47 0.58 0.18 1.24 1.16 8.94 0.88 2.56 1.13 0.40 0.20 0.85 0.97 1.09 0.72 3.12 78 o

o o

35 48 82 146 56 105 69 31 45 52 o

o 31 47 74 o

o o

o o

73 52 27 122 45 o

o 160 o

o o

59 120 o

o o

59 o

P2 P2 P2 P2 Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl P2 P2 Pl Pl Pl P2 P2 P2 P2 P2 Pl Pl Pl Pl Pl P2 P2 8

P2 P2 P2 Pl P2 P2 P2 P2 Pl P2 FROM TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH 01H TEH TEH TEH TEC TEC TEH TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TSH TEC TEC TEC TEC TEC TEC TEC TEC TEC 02H TEC TEC TEC TEH TEH TEC TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TSH TSH TEC TEH TEC TEH TEC TEH TEH TEC TEH TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO peT peT peT peT ONI OSI OSI LOC AV3 AVl AV2 AV4 07H 02H 03H INCH

-0.02 0.00 0.00 0.12 0.00

-0.02 0.10

%TW LENGTH 17%

ANGLE VOLTS PHASE CHAN 33 63 33 65 12%

33 65 20%

34 22 11%

34 26 34 32 34 35 34 36 ONI 05H 0.00 34 37 OSI 03H 0.10 34 41 PSI 02H 0.00 34 41 PSI 06e 0.00 34 41 PSI 06H 0.00 34 43 PSI 06e 0.00 34 48 OSI 02H

-0.02 34 48 OSI 03H

-0.12 34 48 OSI 04H

-0.05 34 34 34 34 34 34 34 34 34 34 34 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 48 SAl 02H 0.12 0.21" 50 peT AVl 0.02 19%

50 peT AV3 0.00 26%

50 peT AV4

-0.12 16%

51 OSI 02H

-0.12 51 OSI 03H

-0.02 51 ONI 08H 0.00 55 55 55 57 19 21 25 25 25 40 41 41 41 41 41 41 50 50 50 peT AVl peT AV2 peT AV3 peT AV2 peT AV4 peT AV3 peT AV2 peT AV3 peT AV4 OSI 02H peT AVl peT AV2 peT AV2 peT AV3 peT AV3 peT AV4 peT AVl peT AV2 peT AV3

-0.05 18%

0.00 18%

0.00 39%

0.00 22%

0.00 17%

0.17 17%

0.00 26%

0.00 29%

0.19 23%

0.02 0.07 22%

0.00 21%

0.25 30%

0.29 11%

-0.29 16%

0.24 30%

0.00 19%

0.00 24%

0.00 24%

Page 14 of 16 1.22 0

P2 0.80 1.54 0.61 1.25 0.26 0.51 1.46 0.63 8.24 9.20 8.74 8.22 0.57 0.81 0.41 0.07 1.42 2.12 1.07 1.44 0.65 1.61 1.29 1.35 5.76 1.70 1.30 1.25 2.36 2.93 1.92 0.42 1.74 1.57 2.89 0.71 1.09 2.89 1.34 1.85 1.92 o

o o

21 103 25 20 15 162 341 163 164 83 64 52 123 o

o o

31 47 48 o

o o

o o

o o

o o

60 o

o o

o o

o o

o o

P2 P2 P2 Pl Pl Pl Pl Pl 8

8 8

8 Pl Pl Pl 6

P2 P2 P2 Pl Pl Pl P2 P2 P2 P2 P2 P2 P2 P2 P2 Pl P2 P2 P2 P2 P2 P2 P2 P2 P2 FROM TEH TEH TEH TEH TEH TEH TEH TO TEe TEe TEe TEe TEe TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEe TEH TEe TEH TEe TEH 02H 02H TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEe TEe TEe TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEe TEe TEe TEH TEH TEH TEH TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEH TEH TEH

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO PCT PCT PCT PCT PCT LOC AV4 AVl AV2 AV2 AV3 INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN 35 50 0.00 20%

35 54 0.00 16%

35 63 0.07 29%

35 63 0.00 21%

35 63 0.00 38%

63 PCT AV4 0.00 21%

71 PCT AV2

-0.05 16%

71 PCT AV4 0.19 18%

19 PSI 06H

-0.24 19 CSI 06H 0.00 25 DSI 05H 0.12 35 35 35 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 37 37 37 37 37 37 37 37 37 37 37 27 PCT TSC 0.19 12%

0.20" 27 VOL TSC 0.19 0.28" 41 PSI 06C 0.00 41 PCT AVl 0.00 31%

41 PCT AV2

-0.22 21%

41 PCT AV3

-0.36 22%

41 PCT AV3 0.22 36%

41 PCT AV4 0.12 29%

42 50 50 54 54 DSI 03H 0.17 PCT AVl PCT AV2 MCI TSH DNI 07H 0.00 0.00

-0.09 0.00 18%

20%

55 PCT AVl 0.00 9%

55 PCT AV2 0.00 18%

58 DSI 05H 0.05 63 PCT AVl 0.00 13%

63 PCT AV2 0.00 18%

63 PCT AV3 0.00 38%

63 PCT AV4 0.00 12%

24 DSI 05H 0.14 29 PCT AVl 0.00 17%

29 PCT AV2

-0.02 23%

32 41 DSI 03H 0.26 PSI 06C 0.00 41 PCT AV2 0.00 15%

57 DSI 02H 0.00 57 DSI 05H 0.10 57 PCT AV2 0.00 19%

57 PCT AV3 0.00 22%

57 PCT AV4 0.00 22%

Page 15 of 16 1.44 0

P2 0.99 2.84 1.69 4.99 1.63 0.91 1.01 7.43 1.00 0.44 0.07 0.10 8.71 3.18 1.62 1.75 4.46 2.83 0.24 1.20 1.40 0.24 1.30 0.51 1.17 0.44 0.82 1.31 4.93 0.79 0.15 1.17 1.85 0.85 8.67 1.01 0.45 0.23 1.29 1.65 1.60 o

o o

o o

o o

227 142 24 o

94 165 o

o o

o o

85 o

o 139 41 o

o 38 o

o o

o 83 o

o 42 163 o

48 33 o

o o

P2 P2 P2 P2 P2 P2 P2 8

9 Pl 3

6 8

P2 P2 P2 P2 P2 Pl P2 P2 P2 Pl P2 P2 Pl P2 P2 P2 P2 Pl P2 P2 Pl 8

P2 Pl Pl P2 P2 P2 FROM TEC TEC TEH TEH TEH TEH TEH TEH TEH 06H TEH TSC TSC TEH TEH TEH TEH TEH TEH TEH TEC TEC TSH TEC TEC TEC TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TO TEH TEH TEC TEC TEC TEC TEC TEC TEC 06H TEC TSC TSC TEC TEC TEC TEC TEC TEC TEC TEH TEH TSH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEH TEH TEH TEH

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21B (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DNI DSI DSI DSI PSI LOC 03H 02H 05H 03H 02H INCH

%TW LENGTH 0.05 ANGLE VOLTS PHASE CHAN 37 69 38 35 0.00 39 31 0.00 39 33 0.10 39 41 0.00 39 39 39 39 39 39 39 39 39 40 40 40 40 41 41 42.

42 42 42 42 42 42 42 42 42 42 43 43 43 43 44 44 44 45 45 46 46 41 PSI 06C 0.00 41 PSI 06H 0.00 45 peT AV3 0.00 15%

45 peT AV4 0.00 25%

48 peT AV2

-0.51 21%

48 peT AV3

-0.83 36%

48 peT AV3 0.91 17%

48 peT AV4 0.00 23%

70 peT AV3 0.00 30%

31 DSI 05H 0.05 41 PSI 06e 0.00 42 DSI 02H

-0.02 46 DNI 05H 0.00 31 68 28 29 41 41 41 45 47 47 51 55 55 41 41 41 64 41 48 DSI 05H peT AVl peT AV3 peT AVl PSI 02H PSI 06e PSI 06H DNI 07H peT AVl peT AV2 DSI 04H peT AVl peT AV2 PSI 02H PSI 06e PSI 06H PSI 06H PSI 06H DSI 02H 0.12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

-0.02 58 PSI 06H 0.00 41 PSI 02H 0.00 41 PSI 06H 0.00 41 PSI 02H 0.00 41 PSI 06H 0.00 15%

20%

14%

23%

19%

22%

17%

Page 16 of 16 1.30 55 Pl 0.62 0.24 0.27 8.10 8.76 8.58 0.93 2.07 1.58 4.61 1.15 1.74 2.70 0.23 8.93 0.35 1.29 0.28 0.92 1.34 0.90 8.09 8.76 8.70 2.17 1.71 1.26 0.49 1.60 1.07 7.70 8.25 8.20 9.73 8.85 0.62 9.59 7.60 8.37 7.93 8.83 18 96 49 164 162 167 o

o o

o o

o o

40 165 161 33 94 o

o o

163 160 161 38 o

o 26 o

o 156 162 162 163 160 138 163 162 159 159 152 Pl Pl Pl 8

8 8

P2 P2 P2 P2 P2 P2 P2 Pl 8

P1 Pl Pl P2 P2 P2 8

8 8

P1 P2 P2 Pl P2 P2 8

8 8

8 8

P1 8

8 8

8 8

FROM TEH TEH TEH TEH TEH TEH TO TEe TEe TEe TEe TEe TEe TEH TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEH TEe TEH TEe TEH TEH TEe TEH TEH TEH TEH TEH TEH TEH TEe TEe TEe TEe TEe TEe TEH TEH TEH TEH TEH TEe TEH TEH TEH TEH TEH TEe TEe TEH TEe TEe TEe TEe TEe TEe TEe TEH TEH TEH TEH TEH TEH TEe TEe TEe TEe TEe TEH TEe TEe TEe TEe TEe

Attachment C BEAVER VALLEY UNIT #2 2R16 SG EXAMINATION RESULTS 2RCS-SG21C TUBES WITH SERVICE INDUCED INDICATIONS

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND SCI SCI LaC TSH TSH INCH

%TW LENGTH

-0.11 VOLTS PHASE CHAN FROM TSH TSH TO TSH TSH 1

48 1

64

-0.11 1

2 2

2 2

2 2

2 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

4 4

4 4

4 4

4 4

4 4

4 4

4 73 SCI TSH

-0.09 21 DNI 04H 0.00 21 DNI 06H

-0.04 55 DNI 06H 0.00 78 DSI 03H 0.03 80 DSI 03H

-0.03 84 DNI 04H 0.00 85 DSI 03H 0.00 4

DNI 07H 0.00 9

DSI 06H 0.04 17 DNI 08H 0.00 18 DSI 03H 0.00 32 DNI 05H 0.00 35 DSI 05H 0.00 39 DSI 07H 0.11.

45 DSI 02H 0.00 58 DSI 02H 0.00 58 DNI 03H 0.12 60 DSI 02H 0.00 60 DSI 03H

-0.01 64 DSI 02H 0.00 64 DSI 03H

-0.13 80 DSI 02H

-0.01 90 DNI 06H 0.00 93 DSI 04H 0.00 94 DNI 03H 0.00 94 DNI 05H 0.00 3

DSI 04H

-0.04 11 DNI 05H 0.00 26 DSI 03H 0.03 26 DNI 07H 0.00 31 MCI TSH

-0.12 32 DNI 04H 0.00 32 DNI 06H 0.00 32 DNI 08H 0.00 33 DSI 02H 0.27 34 DNI 06H 0.00 34 DNI 08H 0.00 38 DNI 05H 0.00 39 DSI 07H 0.05 Page 1 of 18 0.18 140 P2 0.11 0.14 1.48 1.41 1.29 0.32 0.35 1.31 0.54 1.32 0.18 1.29 0.38 1.71 0.20 0.36 0.s5 1.27 1.15 0.50 0.37 0.52 0.77 0.50 1.33 0.36 1.71 1.62 0.19 1.44 0.79 1.48 0.08 1.79 1.59 1.46 0.98 1.29 1.29 1.29 0.60 111 121 18 22 51 98 33 52 15 43 127 49 70 24 122 47 95 SO 34 SO 49 46 45 101 48 108 51 31 47 52 107 43 102 29 28 23 88 43 27 19 38 P2 P2 Pl Pl Pl Pl Pl TSH TSH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH Pl 08H TEH Pl 08H TEH Pl 08H TEH Pl 08H TEH Pl 08H TEH Pl 08H TEH Pl 08H TEH Pl 08H TEH Pl

. 08H TEH Pl 08H TEH Pl 08H TEH Pl 08H TEH Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH TSH TSH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH 08H TEH

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN 4

39 SAl 07H 0.11 0.42" 4

48 OSI 02H

-0.07 4

49 OSI 03H 0.07 4

69 4

76 4

80 4

80 4

80 4

81 OSI 03H OSI 03H ONI 04H ONI 05H ONI 07H ONI 04H 0.00 0.00 0.00 0.00 0.00 0.00 4

81 ONI 07H 0.00 4

82 ONI 05H 0.00 5

6 OSI 03H 0.05 5

6 OSI 04H 0.07 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 6

6 6

6 6

6 6

7 OSI 02H 0.07 7

OSI 03H 0.24 15 OSI 03H 0.00 18 OSI 02H 0.02 19 OSI 02H 0.05 21 SCI TSH

-0.03 27 ONI 06H 0.00 28 SCI TSH

-0.12 29 SCI TSH

-0.16 29 ONI 08C 0.00 35 SCI TSH

-0.11 62 OSI 02H 0.10 66 OSI 03H 0.00 68 ONI 07H 0.00 71 OSI 02H 0.05 76 OSI 03H 0.07 81 ONI 07H

-0.05 86 ONI 03H 0.00 86 OSI 08H 0.00 88 ONI 06H 0.00 89 OSI 02H 0.00 89 ONI 04H 0.29 23 OSI 02H 0.02 30 OSI 02H 0.00 30 OSI 03H 0.02 50 ONI 05H 0.00 54 OSI 03H 0.10 55 OSI 02H 0.02 63 OSI 02H 0.00 Page 2 of 18 0.13 117 6

0.27 0.69 0.55 0.33 1.43 1.36 1.41 1.45 1.31 1.36 0.47 0.30 0.40 0.73 0.48 0.61 0.61 0.11 1.39 0.13 0.24 1.23 0.55 0.19 0.64 1.35 0.49 0.58 1.39 1.79 1.07 1.38 0.54 1.38 0.40 0.47 0.26 1.36 0.74 0.39 0.53 94 44 46 61 55 47 40 54 50 54 118 42 100 83 22 70 53 55 54 75 114 39 138 94 61 46 62 40 40 42 15 41 71 46 93 91 104 52 65 74 89 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl P2 P2 Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM 07H 08H 08H 08H 08H 08H 08H 08H 08H 08H 08H TEH TEH TEH TEH TEH TEH TO 07H TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEH TEC TSH TSH TEH TEC TSH TSH TSH TSH TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO ONI Mel ONI LOC 04H TSH 05H INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN 6

63 0.00 6

69 0.03 6

76 0.00 6

6 6

6 7

7 7

7 7

7 7

7 7

7 7

7 7

7 8

8 8

8 8

8 8

8 8

8 8

9 9

9 9

9 9

9 9

9 9

76 ONI 07H 0.00 78 OSI 03H 0.05 84 OSI 03H 0.25 92 OSI 04H 0.00 7

ONI 07e 0.00 7

ONI 07H 0.00 7

ONI 08H 0.00 9

ONI 02H

-0.02 40 OSI 03H 0.00 40 OSI 04H 0.05 41 Mel TSH

-0.05 49 OSI 02H 0.05 49 OSI 03H 0.17 58 OSI 02H 0.02 62 67 80 93 2

12 15 21 23 23 24 43 63 72 84 20 30 32 35 37 38 39 41 44 45 ONI 04H OSI 02H OSI 03H ONI 03H OSI 08H ONI 02H ONI 03H ONI 04H OSI 02H ONI 06H OSI 02H OSI 03H OSI 06H OSI 03H OSI 03H OSI 04H OSI 02H OSI 02H OSI 02H OSI 02H OSI 03H OSI 05H OSI 02H OSI 03H OSI 05H 0.00

-0.02 0.00 0.00 0.05 0.00 0.07 0.00 0.05 0.00 0.00

-0.02

-0.02 0.00 0.17 0.07 0.00 0.00 0.10 0.02 0.02 0.10 0.15 0.05 0.10 Page 3 of 18 1.28 0.18 1.29 1.31 0.74 0.88 45 55 53 51 38 91 0.65 31 2.05 9

2.59 15 2.29 9

1.50 47 0.50 71 0.66 54 0.11 117 0.58 88 0.41 77 0.74

. 76 1.59 0.71 0.30 1.25 0.61 1.26 1.30 1.40 0.70 1.40 0.60 0.24 0.28 0.47 0.53 0.32 0.36 0.43 0.58 0.53 0.40 0.54 0.33 0.33 0.49 45 45 74 16 12 53 37 15 72 53 86 79 52 16 131 150 81 54 82 87 99 111 96 52 67 Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TSH TEH TEH TEH TEH TO TEe TSH TEe TEe TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TSH TSH TEH TEe TEH TEe TEH TEe TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND DSI SCI LOC 06H TSH INCH

%TW LENGTH ANGLE 9

45 0.02 9

47

-0.13 9

47 OSI 02H 0.10 9

54 OSI 02H 0.00 9

54 OSI 04H 0.17 9

65 OSI 06H 0.15 9

73 ONI 08H 0.00 9

74 ONI 06H 0.00 9

88 ONI 04H 0.00 9

88 ONI 06H 0.00 9

91 ONI 04H 0.00 10 7

ONI 05H 0.00 10 8

OSI 02H

-0.02 10 9

OSI 03H 0.20 10 10 OSI 02H 0.00 10 10 OSI 03H 0.12 1015 ONI 07H 0.00 10 24 OSI 03H 0.05 10 32 ONI 03H 0.00 10 36 OSI 02H 0.07 10 10 10 37 OSI 02H 0.07 38 SCI TSH

-0.10 38 OSI 07H

-0.10 10 43 OSI 02H 0.02 10 44 OSI 02H 0.05 10 51 OSI 02H 0.02 10 51 ONI 05H 0.00 10 51 OSI 05H 0.07 10 54 OSI 02H 0.00 10 54 OSI 03H 0.17 10 69 ONI 04H 0.00 10 72 OSI 02H

-0.05 10 72 OSI 03H 0.00 10 72 ONI 07H 0.00 10 78 OSI 03H 0.10 11 7

OSI 02H

-0.02 11 17 OSI 02H 0.02 11 17 ONI 04H

-0.15 11 17 ONI 06H 0.00 11 11 11 18 ONI 03H 0.00 36 SCI TSH

-0.08 36 OSI 02H 0.07 Page 4 of 18 VOLTS PHASE 0.40 68 0.16 136 0.50 0.38 0.78 0.64 1.33 1.50 1.27 1.38 1.37 1.35 0.87 0.45 0.82 0.66

  • 1.38 0.50 1.36 0.28 0.94 0.21 0.47 0.33 0.87 1.56 1.59 0.79 0.85 0.90 1.32 0.42 0.24 1.37 0.28 0.63 1.11 1.98 1.33 1.72 0.29 0.66 38 56 79 37 50 52 26 40 32 50 49 85 79 47 38 89 23 121 81 107 135 64 123 64 49 18 76 102 24 63 27 45 17 74 64 46 54 77 95 26 CHAN Pi P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl FROM TEH TSH TO TEC TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TSH TEH TEC TSH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TSH TEH TEC TSH TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO ONI ONI OSI ONI ONI OSI LOC 04H 06H 02H 06C 04H 02H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN 11 36 11 36 0.00 11 42 0.02 11 42 0.00 11 48 0.00 11 49 0.07 11 11 11 11 11 11 11 11 11 11 11 11 11 11 12 12 12 12 12 12 12 12 12 12 12 12 12 13 13 13 13 13 13 13 13 13 49 OSI 03H 0.17 50 SCI TSH

-0.08 50 ONI 03H 0.00 54 ONI 03H 0.00 54 ON I 06H 0.00 62 OSI 03H 0.05 70 OSI 03H 0.00 70 ONI 04H 0.00 72 OSI 03H 0.00 78 ONI 06H 0.00 88 ONI 04H

-0.20 88 OSI 05H 0.00 88 ONI 06H 0.00 89 ONI 05H 0.00 9

OSI 02H 0.07 26 ONI 02H 0.00 27 ONI 06H 0.10 30 OSI 02H 0.07 35 OSI 04H 0.15 39 SCI TSH

-0.10 55 OSI 02H

-0.10 59 70 70 70 83 92 27 32 35 35 43 43 59 63 64 ONI 04H OSI 02H OSI 03H ONI 05H OSI 03H ONI 04H ONI 02H OSI 02H ONI 05H ONI 07H OSI 02H OSI 03H OSI 03H OSI 02H OSI 02H

-0.02 0.02 0.00 0.00 0.12

-0.15 0.00 0.10 0.00 0.00 0.02 0.15 0.07 0.05 0.02 Page 5 of 18 1.82 1.68 0.90 2.12 1.63 0.92 0.77 0.18 1.39 1.30 1.39 0.71 0.70 1.33 0.52 1.28 1.48 0.25 1.39 1.38 0.54 1.29 1.32 0.52 0.20 0.25 0.80 1.57 0.48 0.28 1.42 0.30 1.50 1.34 0.27 1.59 1.64 0.27 0.33 0.39 0.47 0.68 50 45 46 16 16 38 66 66 29 18 45 18 30 54 37 38 43 122 36 45 46 28 46 59 67 117 54 54 72 80 40 56 41 35 48 55 38 37 103 30 30 65 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 FROM TEH TEH TEH TEH TEH TEH TEH TSH TEH TEH TO TEC TEC TEe TEe TEe TEe TEe TSH TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEe TSH TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL 13 74 IND ONI ONI LOC 05H 07H INCH

%TW LENGTH 0.00 13 74 0.00 14 14 14 14 14 14 14 14 14 14 14 14 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 16 16 16 16 16 16 16 16 16 17 ONI 05H 0.05 27 ONI 08H 0.00 29 OSI 04H 0.00 29 SAl 04H 0.02 38 OSI 02H 0.05 39 OSI 05H 0.12 43 ONI 03H 0.00 50 OSI 02H 0.00 54 OSI 02H 0.00 59 OSI 03H 0.02 70 ON I 04H 0.00 70 OSI 08H 0.12 3

ONI 04H 0.00 5

OSI 04H 0.15 5

ONI 06H 0.00 5

ONI 08H 0.00 11 ONI 06H 0.00 11 ONI 07H 0.00 14 OSI 03H 0.10 35 OSI 02H 0.00 35 OSI 03H 0.07 38 OSI 04H 0.02 38 SAl 04H

-0.09 39 OSI 02H 0.07 61 OSI 02H 0.07 62 OSI 02H 0.07 78 ONI 04H

-0.17 78 ONI 06H 0.00 78 ONI 08H 0.00 80 OSI 03H 0.05 87 OSI 03H

-0.10 15 OSI 03H 0.20 15 ONI 07H 0.15 15 ONI 08H 0.00 16 ONI 06H 0.00 17 OSI 02H 0.00 34 ONI 03H 0.00 44 ONI 03H 0.00 46 OSI 04H 0.15 46 ONI 06H 0.00 0.23" 0.28" ANGLE VOLTS PHASE CHAN 1.29 42 Pl 1.30 41 Pl 1.27 1.31 0.18 0.12 0.49 0.54 1.41 0.58 0.58 0.38 1.28 0.35 1.29 0.74 1.30 1.27 1.37 1.11 0.57 0.13 0.25 0.46 0.15 0.46 0.40 0.30 1.41 1.30 1.30 0.15 0.34 0.72 1.27 1.28 1.93 0.62 1.41 1.25 0.55 1.40 41 18 73 114 54 48 44 104 53 40 47 27 47 36 59 45 40 44 41 79 56 37 65 96 40 33 51 41 39 39 132 66 44 43 48 37 51 19 30 52 Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Page 6 of 18 FROM TEH TEH TEH TEH TEH TO TEe TEe TEe TEe TEe 04H 05H TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe*

TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe 04H 04H TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO OSI LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO TEC TEC TEC 16 55 06H

-0.07 16 16 57 OSI 03H 0.05 63 OSI 02H 0.05 16 73 OSI 02H 0.07 17 9

OSI 04H 0.07 17 9

SAl 04H

-0.10 17 14 OSI 04H 0.05 17 17 OSI 02H 0.02 17 18 OSI 02H 0.00 17 24 OSI 04H 0.10 17 26 OSI 03H 0.02 17 35 OSI 03H 0.07 17 35 ONI 07H 0.00 17 35 SAl 03H

-0.02 17 37 ONI 04H 0.00 17 37 ONI 07H 0.00 17 17 17 17 17 17 43 OSI 02H 0.00 43 ONI 07H 0.00 48 OSI 02H

-0.12 49 OSI 02H 0.02 50 OSI 03H 0.02 50 SAl 03H 0.01 17 53 ONI 08H 0.00 17 58 ONI 03H 0.00 17 61 OSI 02H 0.07 17 61 OSI 03H 0.15 17 63 OSI 02H 0.05 17 66 OSI 02H 0.00 17 67 OSI 02H

-0.05 17 68 OSI 02H

-0.05 17 82 ONI 06H

-0.02 18 6

ONI 08H 0.00 18 15 ONI 02H 0.05 18 15 OSI 06H 0.07 18 15 ONI 08C 0.00 18 15 ONI 08H 0.00 18 30 ONI 03H 0.00 18 18 18 18 18 36 ONI 08H 0.00 38 OSI 02H

-0.05 43 SCI TSH

-0.10 47 OS.!

03H 0.10 48 OSI 02H 0.10 0.23" 0.23" 0.16" Page 7 of 18 0.55 142 Pl TEH 0.41 0.30 0.72 0.40 0.10 0.26 0.38 0.58 0.16 0.25 1.00 1.27 0.07 1.48 1.55 0.70 1.29 0.83 0.53 0.49 0.13 1.28 1.56 1.12 0.42 0.75 0.46 0.72 0.41 1.39 1.32 1.58 0.17 1.64 1.53 1.27 1.28 0.73 0.17 0.64 0.94 41 40 110 41 95 42 43 33 60 129 43 49 98 45 31 132 41 37 70 70 50 43 44 56 65 53 91 58 56 52 38 52 78 32 39 50 50 99 40 48 161 Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl TEH TEH TEH TEC TEH TEC 04H 04H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 03H 03H TEH TEC TEH TEC TEH*

TEC TEH TEC TEH TEH TEH 03H TEC TEC TEC 03H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TSH TEH TEH TEC TEC TSH TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 18 48 OSI 03H 0.00 18 48 OSI 04H 0.05 18 50 OSI 02H 0.07 18 51 OSI 02H 0.00 18 51 ONI 04H 0.00 18 53 OSI 02H 0.00 18 53 ONI 03H 0.17 18 53 ONI 04H 0.00 18 54 OSI 02H 0.07 18 54 OSI 03H 0.10 18 54 ONI 06H 0.00 18 55 OSI 02H 0.02 18 55 ONI 03H 0.00 18 55 ONI 04H 0.00 18 55 ONI 08H 0.00 18 62 OSI 02H 0.00 18 62 OSI 03H

-0.02 18 62 OSI 04H 0.10 18 67 OSI 02H 0.07 18 67 OSI 03H 0.17 18 73 OSI 03H 0.10 19 20 ONI 02H 0.00 19 20 ONI 04H 0.00 19 25 ONI 04H

-0.02 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 26 OSI 03H 0.05 29 SCI TSH 0.00 29 OSI 02H

-0.02 29 ONI 08H 0.00 38 OSI 02H 0.07 38 OSI 05H 0.07 38 ONI 08H 0.00 38 SAl 02H 0.27 38 SAl 02H

-0.28 39 ONI 07H 0.00 39 ONI 08H 0.00 47 ONI 02H 0.00 47 ONI 04H 0.00 47 ONI 05H 0.00 48 OSI 02H

-0.02 48 OSI 03H 0.05 53 ONI 08H 0.00 54 OSI 02H 0.05 0.30" 0.23" Page 8 of 18 0.72 0.82 0.41 0.95 1.49 1.05 1.47 1.40 0.95 0.36 1.43 0.53 1.97 1.36 1.38 0.54 0.59 0.16 0.45 0.83 0.46 2.06 1.34 1.46 0.38 0.11 0.47 1.41 0.62 1.07 1.40 0.22 0.10 1.71 1.27 1.38 2.00 1.29 0.76 0.74 1.37 0.41 56 31 46 70 48 59 47 48 49 93 39 89 53 54 41 89 113 92 74 69 24 25 20 43 68 75 88 44 46 45 51 97 109 44 48 43 32 42 53 51 38 72 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl 6

6 Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 02H 02H 02H 02H TEH TEC TEH TEC TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO ONI OSI OSI Mel ONI OSI ONI ONI ONI ONI ONI LOC 05H 04H 05H TSH 07H 02H 04H 05H 05H 06H 07H INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN 19 56 0.00 19 57 0.07 19 57 0.00 19 65

-0.08 19 74 0.00 19 79

-0.07 20 7

0.00 20 9

0.00 20 13 0.00 20 13 0.00 20 13 0.00 20 20 20 20 20 20 20 20 20 20 20 20 20 20 21 21 21 21 21 21 21 21 21 21 21 21 21 21 22 22 22 17 ONI 07H 0.00 75 Mel TSH

-0.06 75 OSI 02H

-0.07 76 OSI 02H

-0.02 76 ONI 06H 0.00 76 SAl* 02H 0.13 78 80 80 82 82 84 85 88 18 18 25 31 62 67 78 78 78 80 80 82 84 88 15 18 20 ONI 08H ONI 06H ONI 07H ONI 05H ONI 06H ONI 04H OSI 03H ONI 03H OSI 02H OSI 03H OSI 04H ONI 06H OSI 02H OSI 07H ONI 04H ONI 06H ONI 08H ONI 04H ONI 05H ONI 04H ONI 03H ONI 03H ONI 05H OSI 02H OSI 02H 0.00 0.00 0.00 0.00 0.00 0.00 0.12 0.00 0.00 0.15 0.10 0.00 0.07

-0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.38" Page 9 of 18 1.31 0.65 0.74 0.22 1.31 0.78 1.25 1.27 1.33 1.25 1.48 1.34 0.23 0.65 0.74 1.52 0.12 1.40 1.32 1.28 1.29 1.28 1.95 0.36 1.41 0.43 0.60 0.18 1.26 0.54 0.37 1.47 1.68 1.31 1.43 1.44 1.50 1.26 1.28 1.42 0.53 1.03 54 18 58 129 40 121 35 38 43 43 39 39 87 128 125 54 92 45 49 43 50 49 38 65 52 48 125 54 36 67 159 50 42 35 55 45 50 49 23 32 86 84 Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TSH TEH TEH TEH TEH TEH TEH TEH TEH TSH TEH TEH TEH TO TEe TEe TEe TSH TEe TEe TEe TEe TEe TEe TEe TEe TSH TEe TEe TEe 02H 02H TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO ONI ONI ONI OSI ONI LOC 07H 05H 06H 03H 03H INCH

%TW LENGTH 0.00 22 20 22 21 0.00 22 21 0.00 22 24 0.00 22 30 0.00 22 22 22 22 22 22 22 22 22 22 22 22 22 33 OSI 02H 0.00 35 ONI 02H 0.00 36 ONI 04H

-0.05 37 SCI TSH

-0.14 39 ONI 08H 0.00 61 OSI 03H 0.12 64 OSI 03H 0.10 72 ONI 04H 0.00 72 ONI 05H 0.00 74 ONI 03H 0.00 74*

ONI 04H 0.00 74 ONI 05H 0.00 77 OSI 03H 0.00 23 10 OSI 02H 0.10 23 13 ONI 02H 0.00 23 13 ONI 04H 0.00 23 28 OSI 03H 0.05 23 35 ONI 04H 0.00 23 37 OSI 02H 0.00 23 39 OSI 02H 0.07 23 39 OSI 05H 0.00 23 42 OSI 02H 0.05 23 42 OSI 03H 0.02 23 43 ON I 06H 0.00 23 69 OSI 03H 0.02 23 70 ONI 08H 0.00 23 77 OSI 02H 0.02 23 78 ONI 05H 0.00 23 78 ONI 06H 0.00 23 84 ONI 04H 0.00 24 11 ONI 03H 0.00 24 11 ONI 05H 0.00 24 13 ONI 04H 0.00 24 19 ONI 07H 0.00 24 34 ONI 03H 0.00 24 34 ONI 05H 0.00 24 34 OSI 08H 0.00 ANGLE Page 10 of 18 VOLTS PHASE 1.56 44 1.74 45 1.74 42 0.43 94 1.37 41 0.52 1.35 1.43 0.15 1.37 0.44 0.21 1.40 1.36 1.43 1.75 1.47 0.33 0.67 1.35 1.36 0.40 1.32 0.75 0.53 0.47 0.59 0.62 1.44 0.35 1.36 0.56 1.65 1.32 1.51 1.73 1.67 1.26 1.40 1.84 1.57 0.51 49 55 29 106 38 51 149 55 47 44 39 26 119 32 48 53 69 36 43 80 63 30 71 45 28 28 52 39 49 49 52 44 16 40 47 43 31 CHAN Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TSH TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TEC TEC TEC TEC TEC TEC TEC TEC TSH TEC TEC TEC TEC TEC TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 24 24 24 41 OSI 02H 0.07 41 OSI 04H 0.07 41 SAl 04H

-0.01 24 48 OSI 03H 0.29 24 50 OSI 02H 0.02 24 50 ONI 06H 0.00 24 56 OSI 03H 0.17 24 57 OSI 02H 0.07 24 60 ONI 03H 0.00 24 61 OSI 02H 0.12 24 62 ONI 05H 0.00 24 63 OSI 04H 0.00 24 64 ONI 04H 0.00 24 64 ONI 05H 0.00 24 74 ONI 06H 0.00 24 78 ONI 04H 0.00 24 78 ONI 05H 0.00 24 78 ONI 07H 0.00 24 80 ONI 06H 0.00 80 ONI 07H 0.00 84 ONI 03H 0.00 0.34" 24 24 24 24 25 84 PCT TSC 0.06 29%

0.35" 84 VOL TSC 0.07 0.37" 17 OSI 03H 0.05 25 25 ONI 04H 0.00 25 26 OSI 04H 0.00 25 29 OSI 03H

-0.02 25 29 ONI 04H 0.00 25 31 OSI 02H 0.07 25 33 ONI 04H 0.00 25 33 OSI 08H 0.00 25 34 OSI 02H 0.00 25 34 OSI 03H 0.02 25 34 OSI 05H 0.00 25 38 ONI 04H 0.00 25 38 ONI 06H 0.00 25 47 OSI 03H

-0.02 25 47 ONI 04H 0.00 25 47 OSI 08H 0.05 25 54 OSI 02H

-0.05 25 60 OSI 02H 0.15 25 61 OSI 02H 0.00 Page 11 of 18 0.72 0.41 0.18 1.16 0.42 1.41 0.80 0.41 1.26 0.73 1.31 0.35 1.30 1.35 1.63 1.50 1.28 1.26 1.26 1.25 1.44 0.30 0.35 0.52 1.28 0.25 0.46 1.36 0.51 1.41 0.19 0.85 0.93 0.67 1.29 1.37 0.44 1.33 0.52 0.40 0.53 0.78 37 78 92 50 66 50 92 37 47 74 35 30 55 31 37 53 36 46 49 44 57 110 89 70 52 61 65 51 63 39 86 66 110 21 47 53 17 49 20 39 90 100 Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 3

6 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEH 04H TEC TEC 04H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEH TSC TSC TEH TEC TEC TSC TSC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO ONI OSI LOC 05H 04H INCH

%TW LENGTH

-0.20 ANGLE VOLTS PHASE CHAN 25 61 25 62

-0.02 25 25 25 25 25 25 25 25 25 64 65 65 71 72 ONI 08H OSI 02H ONI 07H MCI TSH ONI 07H 0.00 0.00 0.00

-0.08 0.00 74 OSI 02H 0.02 74 SAl 02H 0.00 76 OSI 02H 0.00 76 OSI 05H 0.00 25 76 ONI 06H 0.00 25 76 ONI 08H 0.00 25 78 ONI 08H 0.00 25 79 OSI 02H 0.07 25 80 ONI 03H 0.00 26 17 ONI 03H 0.00 26 17 ONI 05H 0.00 26 17 ONI 06H 0.00 26 19 ONI 08H 0.00 26 24 OSI 06H 0.02 26 26 OTI TEC 16.08 26 30 ONI 07H 0.10 26 38 OSI 05H 0.05 26 39 OSI 05H 0.07 26 42 OSI 02H 0.00 26 44 OSI 06H 0.00 26 45 ONI 06H 0.15 26 60 ONI 04H 0.00 26 65 OSI 03H 0.00 26 70 OSI 03H 0.10 26 72 OSI 08H 0.10 26 26 26 26 26 27 27 27 27 27 74 ONI 05H 0.00 75 MCI TSH

-0.12 76 ONI 05H 0.00 78 ONI 05H 0.00 78 ONI 07H 0.00 12 ONI 04H 0.00 17 ONI 04H 0.00 20 OSI 02H

-0.05 21 ONI 02H

-0.05 22 OSI 02H 0.05 0.26" Page 12 of 18 1.29 44 Pl 0.39 1.79 0.34 1.50 0.19 1.34 0.36 0.12 0.76 0.30 1.55 1.52 1.30 0.39 1.53 1.64 1.47 1.62 1.28 0.43 6.57 1.28 0.49 0.54 0.47 0.26 1.62 1.74 0.19 0.66 0.48 1.37 0.20 1.28 1.37 1.30 1.29 1.42 0.73 1.96 0.41 129 24 95 51 67 55 107 124 94 97 54 47 52 53 54 24 20 21 24 11 155 35 34 27 42 57 13 37 125 81 64 52 96 53 50 40 24 25 88 13 51 Pl Pl Pl Pl P2 Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TSH TEH TEH 02H TEH TEH TO TEe TEe TEe TEe TEe TSH TEe TEe 02H TEe TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TSH TEH TEH TEH TEH TEH TEH TEH TEH TEe TSH TEe TEe TEe TEe TEe TEe TEe TEe

Beaver Valley Unit #2 2R 16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO ONI LOC 04H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN FROM TO TEe 27 23 27 23 ONI 07H 0.00 27 23 ONI 08H 0.00 27 24 OSI 04H 0.07 27 30 OSI 02H 0.10 27 30 ONI 08H 0.00 27 31 ONI 05H 0.00 27 31 ONI 06H 0.00 27 35 ONI 04H 0.00 27 35 ONI 07H 0.00 27 60 OSI 02H 0.12 27 69 OSI 02H 0.00 27 70 ONI 05H 0.00 27 76 OSI 03H 0.07 28 11 ONI 04H 0.00 28 14 ONI 02H 0.00 28 18 ONI 05H 0.00 28 21 ONI 04H 0.00 28 23 ONI 05H 0.00 28 23 ONI 07H 0.00 28 27 OSI 05H 0.05 28 27 ONI 08H 0.00 28 29 ONI 03H 0.00 28 35 OSI 02H 0.00 28 35 ONI 07H 0.00 28 37 ONI 05H 0.00 28 37 ONI 07H 0.00 28 42 OSI 02H 0.05 28 42 OSI 04H 0.07 28 44 OSI 02H 0.00 28 50 OSI 03H 0.00 28 50 ONI 08H 0.00 28 73 OSI 03H 0.07 28 74 ONI 03H 0.00 28 75 ONI 04H 0.00 28 76 ONI 06H 0.00 28 78 ONI 06H 0.00 28 85 OSI 02H 0.00 29 11 ONI 04H 0.00 29 25 ONI 06H 0.00 29 26 OSI 05H 0.27 29 29 OSI 03H 0.25 Page 13 of 18 1.81 56 Pl TEH 1.51 48 1.40 48 0.30 21 0.60 25 1.46 25 1.27 53 1.41 54 1.49 55 1.39 41 0.77 61 0.20 91 1.26 55 0.74 14 1.62 28 1.61 82 1.42 36 1.30 24 1.26 35 1.29 30 0.44 107 1.33 27 1.26 19 0.85 80 1.55 42 1.37 37 1.64 40 0.34 99 0.32 26 0.38 72 0.29 102 1.41 44 0.25 29 1.61 50 1.40 31 1.30 52 1.30 48 0.49 123 1.46 27 1.79 34 0.70 82 0.90 83 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH*

TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND ONI ONI OSI OSI ONI OSI ONI LOC 04H 05H 02H 05H 04H 03H 06H INCH

%TW LENGTH 0.00 ANGLE VOLTS PHASE CHAN 29 29 29 29 0.00 29 37 0.07 29 38 0.07 29 40 0.00 29 43 0.07 29 43 0.00 29 43 ONI 08H 0.00 29 45 ONI 07H

-0.07 29 47 OSI 02H 0.02 29 47 ONI 07H 0.00 29 48 OSI 05H 0.10 29 50 ONI 06H 0.00 29 57 OSI 05H 0.12 29 63 OSI 05H 0.20 29 66 ONI 04H 0.00 29 66 ONI 05H 0.00 29 76 ONI 03H 0.00 30 24 OSI 02H

-0.02 30 25 OSI 04H 0.17 30 31 OSI 03H 0.02 30 31 OSI 04H 0.10 30 41 OSI 02H 0.05 30 55 ONI 06H 0.00 30 55 ONI 08H 0.02 30 57 ONI 07H 0.00 30 58 SCI TSH

-0.06 30 58 ONI 08H 0.00 30 60 OSI 02H 0.00 30 61 OSI 02H 0.07 30 61 OSI 04H 0.02 30 61 SAl 04H 0.06 30 62 ONI 07H 0.00 30 63 OSI 04H 0.02 30 66 ONI 06H 0.00 30 68 MCI TSH

-0.07 30 70 SCI TSH

-0.05 30 80 SCI TSH

-0.18 30 80 ONI 03H 0.00 31 14 OSI 05H 0.02 31 31 17 OSI 04H 0.05 22 OSI 02H 0.05 0.29" Page 14 of 18 1.40 1.31 0.51 0.48 1.26 0.28 1.37 1.32 1.35 0.83 1.26 0.31 1.26 0.32 0.78 1.59 1.25 1.39 0.46 0.24 0.37 0.46 0.22 1.30 1.41 1.31 0.10 1.40 0.60 0.53 0.50 0.11 1.30 0.88 1.51 0.23 0.17 0.15 1.63 0.28 0.41 0.34 43 47 45 48 52 93 46 34 39 72 50 134 53 43 76 46 49 35 66 118 32 44 90 30 21 34 88 33 60 58 68 124 50 26 47 60 101 113 54 76 24 56 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 Pl Pl Pl Pl 6

Pl Pl Pl P2 P2 P2 Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TO TEC TEC TEC TEC TEC TEC TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TSH TSH TEH TEC TEH TEC TEH TEC TEH TEC 04H 04H TEH TEC TEH TEC TEH TEC TSH TSH TSH TSH TSH TSH TEH TEC TEH TEC TEH TEH TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL INO DSI LOC 04H INCH

%TW LENGTH

-0.02 ANGLE VOLTS PHASE CHAN 31 29 31 31 DNI 05H 0.00 31 31 DNI 07H 0.00 31 37 DNI 03H 0.00 31 37 DNI 04H 0.10 31 37 DNI 08H 0.00 31 47 DNI 07H 0.10 31 49 DSI 02H 0.10 31 60 DSI 02H 0.02 31 61 DSI 03H 0.02 31 62 DNI 04H 0.00 31 62 DNI 07H 0.00 31 62 DNI 08C 0.00 31 64 DSI 04H 0.10 31 31 31 31 31 31 31 31 31 31 31 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 33 33 64 DNI 07H 0.00 64 SAl 04H 0.05 66 DSI* 02H 0.00 66 DSI 05H 0.07 66 DNI 08H 0.00 72 DNI 06H 0.00 75 DSI 02H 0.02 75 DNI 07H 0.00 75 SAl 02H 0.00 77 DSI 06H 0.00 78 DNI 07H 0.00 19 DSI 05H 0.05 25 DSI 03H 0.10 35 DNI 08H 0.00 47 DNI 04H 0.00 47 DNI 06H 0.00 47 DNI 08H 0.00 51 DNI 04H 0.00 51 DNI 07H 0.00 63 DSI 03H 0.07 63 SAl 03H 0.06 64 DNI 07H 0.00 72 DNI 03H 0.00 72 DNI 04H 0.00 72 DNI 07H 0.00 72 DNI 07H 0.00 23 DNI 06H 0.00 34 DSI 06H 0.05 0.38" 0.46" 0.28" Page 15 of 18 0.66 1.45 1.32 1.53 1.27 1.52 1.29 0.36 0.39 0.47 1.53 1.30 1.30 0.39 1.33 0.11 0.44 0.64 1.34 1.63 0.26 1.27 0.13 0.27 1.27 0.28 0.42 1.34 1.25 1.96 1.76 1.80 1.25 0.64 0.12 1.35 1.36 1.65 1.37 1.35 1.34 0.54 146 31 40 28 21 21 42 50 58 48 54 44 22 23 42 130 100 27 34 44 105 25 98 54 48 73 45 39 41 19 23 16 14 29 120 48 48 50 48 48 50 12 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl Pl Pl Pl Pl FROM TEH TO TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH 04H TEH TEH TEH TEH TEC 04H TEC TEC TEC TEC TEH TEC TEH TEC 02H 02H TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC 03H 03H TEH TEH TEH TEH TEH TEH TEH TEC TEC TEC TEC TEC TEC TEC

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 33 60 OSI 07H 0.15 33 73 ONI 05H 0.00 34 24 OSI 07H 0.05 34 26 OSI 02H 0.07 34 27 ONI 04H 0.00 34 27 ONI 06H 0.00 34 39 OSI 05H 0.02 34 47 ONI 07H 0.00 34 49 ONI 07H 0.00 34 55 OSI 03H 0.00 34 34 34 35 35 35 35 35 35 35 35 36 36 36 36 36 36 36 36 36 37 37 37 37 37 37 37 37 37 37 37 38 58 OSI 02H 0.05 58 OSI 05H 0.07 59 OSI 02H 0.10 22 OSI 02H 0.02 26 ONI 07H 0.00 34*

OSI 03H 0.07 34*

OSI 04H 0.00 38 OSI 07H 0.02 39 ONI 07H 0.00 43 ONI 03H 0.00 53 OSI 06H 0.10 20 OSI 03H 0.05 26 OSI 05H 0.12 27 OSI 05H 0.07 53 OSI 02H

-0.07 53 SAl 02H 0.03 56 ONI 06H 0.00 58 ONI 06H 0.00 58 ONI 07H 0.00 61 Mel TSH 0.03 23 ONI 03H 0.22 26 OSI 05H 0.00 27 ONI 04H 0.00 27 ONI 06H 0.00 43 ONI 06H 0.00 51 ONI 08e 0.00 52 OSI 06H 0.10 52 ONI 07H 0.00 54 ONI 06H 0.00 67 peT AV2 0.00 23%

67 peT AV3 0.00 28%

33 ONI 04H 0.00 0.30" Page 16 of 18 0.24 1.42 0.37 0.98 1.26 1.28 0.36 1.29 1.40 0.28 0.61 0.35 0.85 0.31 1.87 0.59 0.17 0.26 1.27 1.29 0.21 0.43 0.66 0.34 0.68 0.02 1.26 1.70 1.29 0.15 1.43 0.14 1.26 1.25 1.35 1.53 0.32 1.33 1.28 1.92 2.63 1.43 63 13 34 16 55 55 30 46 40 49 82 39 68 68 20 32 76 54 38 32 133 61 65 56 160 122 54 39 42 57 20 88 33 46 34 15 33 52 43 o

o 46 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl 6

Pl Pl Pl P2 Pl Pl Pl Pl Pl Pl Pl Pl Pl P2 P2 Pl TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe 02H 02H TEH TEe TEH TEe TEH TEe TSH TSH TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEe TEH TEH TEH TEH TEH TEe TEe TEe TEe TEe

ROW COL 38 42 38 54 39 39 39 39 39 39 39 39 39 40 40 40 40 40 40 40 40 40 40 40 41 41 41 41 41 41 41 42 42 42 42 42 42 42 42 43 43 43 43 44 27 29 43 43 49 50 50 51 60 25 43 45 45 47 49 49 50 50 53 54 27 44 50 52 54 54 54 32 43 45 47 47 49 49 52 31 45 45 47 43 IND OSI ONI LOC 05H 06H ONI 04H ONI 04H ONI 06H ONI 07H ONI 06H ONI 06H ONI 08H ONI 04H ONI 05H OSI 03H ONI 08H ONI 06H ONI 08H ONI 07H ONI 03H ONI 08H ONI 06H ONI 08H OSI 04H ONI 08e OSI 04H OSI 04H OSI 08H ONI 08H ONI 04H ONI 06H ONI 08H OSI 04H ONI 07H ONI 08H ONI 04H ONI 07H ONI 04H ONI 08H ONI 03H ONI 03H ONI 04H ONI 08H ONI 06H ONI 06H Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INOUCED INDICATIONS)

INCH

%TW LENGTH 0.07 ANGLE VOLTS PHASE CHAN 0.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.07 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.07 0.00 0.02 0.12

-0.03 0.00 0.00

-0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Page 17 of 18 0.18 1.48 1.32 1.31 1.62 1.61 1.56 1.36 1.28 1.58 1.31 0.23 1.36 1.53 1.27 1.33 1.27 1.29 1.43 1.50 0.24 1.26 0.35 0.16 0.24 1.45 1.26 1.40 1.25 0.44 1.35 1.30 1.45 1.30 1.31 1.63 1.26 1.36 1.52 1.67 1.46 1.46 103 48 43 41 23 26 55 47 41 29 40 69 45 44 47 44 50 40 47 41 133 32 43 114 61 40 49 41 36 37 41 43 43 40 42 34 55 51 51 44 26 42 Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl Pl FROM TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TEH TO TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe TEe

Beaver Valley Unit #2 2R16 Examination Results 2RCS-SG21C (TUBES WITH SERVICE INDUCED INDICATIONS)

ROW COL IND LOC INCH

%TW LENGTH ANGLE VOLTS PHASE CHAN FROM TO 44 45 DNI 04H 0.00 1.37 45 Pl TEH TEC 44 47 DNI 04H 0.00 1.45 41 Pl TEH TEC Page 18 of 18