JAMES A. FITZPATRICK NUCLEAR POWER PLANT OPERATING DATA REPORT DOCKET NO. 50-333 UNIT NAME FITZPATRICK DATE MAY 1987 COMPLETED BY JOHN COOK TELEPHONE (315) 349-6569 OPERATING STATUS 5

1. UNIT NAME: FITZPATRICK NOTES
2. REPORTING PERIOD: 870401 - 870430
3. LICENSED THERMAL POWER (MWT): 2436
4. NAMEPLATE RATING (GROSS MWE): 883
5. DESIGN ELECTRICAL RATING (NET MWE): 816
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 823
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 794

.8. IF CHANGES OCCUR IN CAPACITY PATINGS (ITEMS 3 - 7) SINCE LAST REPORT, GIVE REASONS:

NONE

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NONE
10. REASONS FOR RESTRICTIONS, IF ANY:

THIS MONTH YR-TO-DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD: 720 2880 103081 i
12. NUMBER OF HOURS REACTOR WAS CRITICAL: 205.3 561.5 74052.9
13. REACTOR RESERVE SHUTDOWN HOURS: 0 0 0
14. HOURS GENERATOR ON-LINE: 7.8 362.9 71821.2
15. UNIT RESERVE SHUTDOWN HOURS: 0 0 0
16. GROSS THERMAL ENERGY GENERATED (MWH): 38448 702816 154835938
17. GROSS ELECTRICAL ENERGY GENERATED (MWH): 1200 221270 53044230
18. NET ELECTRICAL ENERGY GENERATED (MWH): 1145 212010 50792140
19. UNIT SERVICE FACTOR: 1.0% 12.6% 69.7% I
20. UNIT AVAILABILITY FACTOR: 1.0% 12.6% 69.7%
21. UNIT CAPACITY FACTOR (USING MDC NET): 0.2% 9.2% 63.5%
22. UNIT CAPACITY FACTOR (USING DER NET): 0.2% 9.0% 60.4%
23. UNIT FORCED OUTAGE RATE: 0.0% 0.0% 12.0%
24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE AND DURATION OF EACH):
25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMTED DATE OF STARTUP:
26. UNITS IN TEST STATUS (PRIOR TO C0f44ERCIAL OPERATION): FORECAST ACHIEVED INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION t

- ')h 8705120341 870430 <

ADOCK 05000333 PDR R PDR y,t '. j l

[: ,

s:

~

-MES' A. FITZPATRICK' NUCLEAR POWER PLANT. i -

-AVERAGE DAILY UNIT POWER LEVEL'

~*

DOCKET'Noi50-333' ~

UNIT: 1FITZPATRICKu' DATE: MAY.1987*

f -

COMPLETED BY:. John Cook-TELEPHONE:.C315)349-6569-MONTH i' APRIL 1987

- DAY' AVERAGE' DAILY POWER LEVEL- DAY' . AVERAGE DAILY. POWER LEVEL-We NET- Ne ET 1 0- 17 0 2 0 18 0 3 'O 19 0

~4 'O 20 0

^

.~ 5 0 _

21- 0 -

6- 0 22' 0 7- 0 23' 10 8 0 24 0 9 0 25 0-

.10 ~. 0 26 0 11' 0 27- 0-12' 0 -28 0 13 0 29- 0 14- 0 30 48 0 31- ---

16' 0 SLM %RY: The Unit returned to service on the last day of the reporting' period.

  • \

~

'~

JAMES."A.-FITZPATRICK NUCLEARIPOWER PLANT-I'

,g UNIT SHUTDOWNS AND POWER REDUCTIONS

. y .

X

'DOCRET-No:.50-333: -

UNIT NAME:/FITZPATRICK.'.

DATE
1MAY-1987; ,[

REPORT MONTH APRIL 1987 LCOMPLETED.BY: John' Cook' -

TELEPHONE:/(315)349-6569 '

D C-UH .R METHOD <

S .0: -

'R0 E OF- .. Y C .. M . C

. CAUSE AND. CORRECTIVE ACTION AU A SHUTTING LICENSEE- SO PO :TO- .

NO. DATE TYPE TR S DOWN EVENT T D. OD - PREVENT RECURRENCE. /

IS 0 THE REPORT E E- NE O N REACTOR H E N N T

1 870401 S 712.2 C 1 N/A. N/A. N/A SHUTDOWN FOR REFUELING ~ >

END OF CYCLE 7 (CUMULATIVE HOURS;2517.1)

L 1 2 .3 ,

4' F: FORCED REASON: METHOD: EXHIBIT..G. INSTRUCTIONS:

S: SCHEDULED A. EQUIPMENT FAILURE (EXPLAIN). 1-MANUAL : .FOR PREPARATION OF DATA' B. MAINTENANCE OR TEST .2-MANUAL SCRAM ENTRY SHEETS FOR LICENSEE; C. REFUELING 3-AUTOMATIC. SCRAM. -EVENT REPORT;(LER)1 FILE D.l REGULATORY RESTRICTION. ,

'.4-0THER (EXPLAIN)- (NUREG-0161)~'

  • E.~ OPERATOR TRAINING AND LICENSE'EXAMINATIONf ^

F. ADMINISTRATIVE' . . . ,

G. OPERATIONAL ERROR.(EXPLAIN)~. -

~

H. OTHER (EXPLAIN) <

v v v

.. ~

NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE APRIL 1987 The FitzPatrick plant returned to' service on AprI1'~30, 1987, after completing.a refueling and maintenance outage.

'At the end of the reporting period the unit is operating.at-approximately 48 MWe.

^

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT -

MAINTENANCE

SUMMARY

DOCKET NO: 50-333 UNIT NAME: FITZPATRICK DATE: May 7, 1987 COMPLETED BY: JOHN COOK FOR THE MONTH OF: APRIL 1987 TELEPHONE: (315) 349-6569.

WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE- TIME HOURS 870410 00 032966 OPS MOD F1-86-065-OP#1 NO FAIL; REPLACE REPLACE; CHECK .635 PRESS SW'S WITH NEW SOR 870421 00 043237 OPS IMP-T-17 CALIBRATE 02-3 ISP-275A, ISP-275B 5 PT-52C,D ATTS TRANSMITTERS 870419 00 050618 JIC P.M. DO ISP-176A FOR ISP-176A AS DIRECTED 10 VARIOUS MTU'S 870418 00 052130 JIC DAMAGED DURING REPLACE TRIP UNITS PERFORM APPLICABLE 22 MTU'S ATTS MODS ISP'S 870408 00 053487 JIC P.M. DO ISP-126A ISP-126A FOR VARIOUS 20 HPCI TU'S TRIP UNITS 870415 00 053500 JIC LEAD WRONG ON TOP FILE CAL UNIT CONNECT PROPERLY; 4 09-95 MTU-268A MALFUNCTIONS ISP-125A 870423 00 054192 OPS WIRING NEEDED 14-AF-3B FUSE REQUIRED MOD TO 7 14-AF-3B CHANGE BLOWING CORRECT WIRING

NEW YORK POWER AUTHORITY JAMES A FITZPATRICK NUCLEAR POWER PLANT

  • MAINTENANCE

SUMMARY

DOCKET NO: 50-333' UNIT NAME: FITZPATRICK DATE: MAY'7, 1987' COMPLETED BY: JOHN COOK FOR THE MONTH OF: APRIL 1987 TELEPHONE: -(315) 349--6569 WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR' DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE- TIME HOURS 870310 02 050693 JIC OUT OF ADJUSTMENT RTD INPUT SECTION ADJUST ZERO, SPAN, 3 MTU-221D DRIFTING DO ISP-101D 870417 02 053424 JIC INCORRECT WIRING TE'S DID NOT REWIRE PER ECR 12; 31 TE-113D-J RESPOND TO TEST ISP-92-2 870415 02 053470 JIC BROKEN ELEMENT READS OPEN ON REPLACE. ELEMENT; 18 TE-ll2A RECORDER TR-166 TERNIMATE; TEST 870416 02 054108 OPS TWO LEADS ADS TIMER FAILED RE-LABEL AND TERMINATE 10 ADS REVERSED DURING ST-22A PROPERLY 870421 02 054171 OPS UNKNOWN FITTING BROKEN REPALCE WITH NEW PARTS 15 RV-71G ACCUMULATOR 870407 02-3 024960 JIC BAD CONNECTOR BAD COMPUTER CAN'T REPLACE UNTIL 15 TE-67Al POINT B001 S/D SEE WR053471 870407 02-3 034216 JIC BROKEN CONNECTOR BAD COMPUTER REPLACED-STILL PROBLEM 10 TE-67A2 POINT SEE WR 053471 i

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT

  • MAINTENANCE

SUMMARY

DOCKET NO: 50-333 UNIT NAME: FITZPATRICK DATE: May 7, 1987 COMPLETED BY: JOHN COOK FOR THE MONTH OF: APRIL 1987 TELEPHONE: (315) 349-6569 WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR-DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TIME HOURS 870409 02-3 050429 OPS IMPROPER FIT VALVE LEAKS _. REPLACE DRAIN VALVE 6 DPT-62 BY SEAT LO SIDE IMP-2-3.3 870222 02-3 050505 JIC MODIFICATION NO FAILURE; INSTALL PER ISP-176A 10 STU-253C REPLACE.GE WITH ROSEMOUNT 870319 02-3 052481 OPS MODIFICATION REPLACE WITH NEW INSTALLATION PROC #1; 40 PS-51(A-D) M1-87-028 SOR SWITCHES' ISP-70 870410 02-3 053476 JIC GROSS FAILURE CHECK CALIBRATION .ISP-201D; CHECKED OK 3 LT-58B DURING ISOLATION ON LT-58B 870402 03 051309 OPS LOOSE SEAL INST BLOCK LEAKS TIGHTEN LD-129 PER 1 HCU 22-47 NITROGEN GEK 9582A 870201 03 051393 OPS NO PROBLEM CONNECTION IS COMPLETED IMP-3.5 2 HCU 38-47 FOUND @ 2000 PSI LEAKING 870330 03 053325 OPS BYPASS SWITCH OUT CAN'T SELECT A ROD RESET SWITCH 18 RMCS OF SEQUENCE IN START-UP

, ]

'NEW YORK POWER AUTHORITY?

JAMES A. FITZPATRICK NUCLEAR POWER PLANT- -

MAINTENANCE

SUMMARY

DOCKET NO: '50-333 UNIT NAME: FITZPATRICK ~

DATE: May 7, 1987- -

i COMPLETED BY: JOHN ~ COOK.

FOR THE MONTH OF: APRIL 1987- TELEPHONE: (315);349-6569 WORK REQUEST NO. HOW CAUSE OF RESULTS 0F ACTION TAKEN TO REPAIR DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION ' MALFUNCTION PRECLUDE RECURRENCE , TIME HOURS 870328 03 053336 OPS IMPROPER SEAL INST BLOCK LEAKS REPLACE 0-RING, 6 HCU 38-39 NITROGEN SN00P' PIPING 870402 03 053347 OPS LOOSE NUT CABLE FITTING TIGHTEN, CHECK 5 HCU 30-43 LEAKS NITROGEN 870411 03 053477 JIC IMPROPER FIT BRASS FITTING 107 REPLACE FITTING WITH 1 HCU 38-31 VALVE LEAKS NEW FROM STOCK' 870414 03 053824 JIC BAD CARD Z29 R0D SELECT PANEL REPLACE CARD; TEST 10 CARD Z29 FAILED PRE-OP RESPONSE 870418 03 054088 OPS BAD PROBE BUFFER " FULL IN" DOES NOT IMP-3.7; REPLACE CARD 8 ROD 50-31 CARD EXTINGUISH 870420 03 054104 OPS IMPROPER FIT CONNECTION LEAKS REPALCE 0-RING, 12 HCU 38-43 IMP 3.5 870408 06 053480 JIC ZERO INADVERTENTLY NO FAILURE; ADJUST ZER0; 2 PT-53B CHANGED CAL PRESSURE CALIBRATED'SATISF TRANSM

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT -

MAINTENANCE

SUMMARY

. DOCKET NO: 50-333 UNIT NAME: FITZPATRICK DATE: MAY.7, 1987 COMPLETED BY: JOHN COSK FOR THE MONTH OF: APRIL 1987 TELEPHONE: (315) 349-6569 WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE =- TIME HOURS 870408 06 053601 OPS LT-52B OUT OF INCORRECT LEVEL' ISP-4.4; ADJUST 10 LI-94B ADJUSTMENT INDICATION ZERO AND SPAN 870422 06 053603 OPS INDICATOR FAULT PRESSURE REPAIR, CALIBRATE, 12 PT-61A INDICATION LOOP CHECKED DOWNSCALE 870403 06 053905 OPS BAD SLIDE WIRE; BLACK PEN UPSCALE; REPLACE WIRE, 7 PR-97 GEAR NO PAPER ADVANCE REPAIR GEAR 870411 06 053998 OPS BROKEN WIRE RECORDER FAILS TO REPLACE WIRE 8 PR-97 ADVANCE SLOW 870405 07 046492 OPS SLUG TESTED FOUND CANNOT FULLY NONE; C TUBING _ 5 NM-131-4C TO BE OK. INSERT TIP REPLACED WR 50537 870326 07 046502 OPS TUBE PINCHED CH5 MOVES SLOW; REAM OUT AND 30 TIP C WON'T GO TO TOP STRAIGHTEN 870331 07 050506 JIC P.M. NO FAILURE; REPLACE PER IMP-7.20, 198 TIP SHEAR REPLACE EXPLOSIVE IMP-7.21 CARTRIDGES

KZW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT -

MAINTENANCE

SUMMARY

DOCKET NO: 50-333 UNIT NAME: FITZPATRICK DATE: .MAY 7, 1987 COMPLETED BY: JOHN COOK FOR.THE MONTH OF: APRIL 1987 TELEPHONE: (315) 349-6569 WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN-TO .

REPAIR i

.DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION MALFUNCTION PRECLUDE. RECURRENCE ~ . TIME

' HOURS 870419 07 050507 -JIC' RECORDER OUT RECORDER PERF APPL STEPS OF 1 IRM B IS LOW INDICATION IS LOW IMP-7.3, ISP-71 870418 07 050537 JIC P.M. NO FAILURE; INSPECT, TEST, 178 TIP TUBING TEST TUBING REPLACE 870403 07 050629 JIC INSTALL NEW NO FAILURE; INSTALL, REM OUTPUT 32.

NM-102A-D REPLACE TIP TUBE, CHECK INDEX MECH 870325 07 050630 JIC P.M. NO FAILURE; APPLICABLE IMP-7.26, 50 NM-101A-D IMP-7.26 FOR CHECK TIP MECH 870403 07 050666 JIC P.M. NONE; REBUILD REBUILD, REPLACE 12 SRM/IRM DR DETECTORS DRIVE EMCH 870331 07 053093 JIC N/A; WELDING APPEARS TO FAIL TDR TRACE, REPLACE 30 IRM F MAY AFFECT SIGNALS UPSCALE CONNECTOR

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT -

MAINTENANCE

SUMMARY

. DOCKET NO: 50-333 UNIT NAME: FITZPATRICK DATE: MAY 7, 1987 COMPLETED BY: JOHN C00K' FOR THE MONTH OF: APRIL 1987 TELEPHONE: (315) 349-6569.,

WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TIME HOURS 870417 07 053105 OPS NOISE-FROM SPIKING UPSCALE CHECK CONNECTIONS; 120 SRM D UNDER VESSEL REPLACE POWER SUPPLY 870413 07 053492 JIC NEW LPRM'S NO FAILURE; APPLCIABLE STEPS 5 LPRM'S NEW CAL CURRENT OF IMP-7.6 ,

515nA 870422 07 053498 JIC DEFECTIVE LAIG3 DIGITS OUT IN REPLACE LAMPS 30 NM-131A-4D TIP DRAWERS 870408 07 054017 OPS UNKNOWN INDICATING VOLTAGE BREAKDOWN, 6 NM-40D 10,000 CPC HI RES TEST, TDR 870420 07 054105 OPS DIRTY CONTACTS LPRM A BAD CLEAN, ADJUST ZERO 10 LPRM 04-37 INDICATION 870420 07 054153 OPS LOOSE CONNECTOR CABLE J1 PULLED REPAIR CONNECTOR' 10 IRM H OUT 870423 07 054255 JIC SOCKETS K1, K2 F/R LAMPS BRIGHT REPOSITION TO ENSURE 6 NM-131-4B MAY HAVE SHORTED AND DIM NO SHORTS L

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT -

MAIhTENANCE

SUMMARY

DOCKET NO: 50-333 UNIT NAME: FITZPATRICK DATE: MAY 7, 1987 COMPLETED BY: JOHN COOK FOR THE MONTH OF: APRIL 1987 TELEPHONE: (315) 349-6569 WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TIME.

HOURS-870415 10 053311 OPS GAIN NEEDS WET LIGHT STAYS ADJUST GAIN 4 LS-101 ADJUSTMENT ON WHEN DRY 870415 10 054047 OPS FAULTY SENSOR DRY LIGHT WON'T REPLACE BOARD, TEST 10 LS-102 BOARD COME ON ST-2B WITH TEST SETUP 870409 13 041892 OPS LOOSE TERMINALS MTU-207A WENT TIGHTEN TERMINALS 72 RTD-107A UPSCALE 870128 13 050668 JIC AGE AND CORROSION SWITCH FAILED REPLACE MOD F1-86-065, 4 PS-127 IN HOUSING DURING IMP-13.1 WR 00/32966 870131 13 050671 JIC VARIOUS COMPONENTS TRIP UNIT DOES REPLACE METERS, CAPS., 10 MTU-287B BAD, SHORTED NOT OPERATE ISP-151B 870423 13 054210 OPS BLOWN FUSE NO PRESSURE REPALCE FUSE, PERFORM 6 PI-93 INDICATION IMP 13.1 870419 13 054253 JIC DRIFT LOOP NOT IMP-13.3 10 RCIC FLOW LOOP FUNCTIONING PROPERLY

'a NEW YORK POWER. AUTHORITY ,

JAMES A. FITZPATRICK NUCLEAR POWER PLANT' -

' MAINTENANCE.

SUMMARY

DOCKET NO: 50-333' UNIT NAME: FITZPATRICK DATE: MAY'7, 1987-COMPLETED BY: JOHN COOK-g FOR THE; MONTH OF: -APRIL 1987 TELEPHONE: -(315) 349-6569 WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN TO / REPAIR DATE . SYSTEM COMPONENT NO. DETECTED , MALFUNCTION' ~. MALFUNCTION PRECLUDE RECURRENCE, TIME HOURS' 870419 14 '054146 - OPS TIMER PUMP FAILED ADJUST FOR 10 .61 1

.TDE-62-5 REQUIRED TIME SEC ST-9C 870409 16 053478 JIC THREADS DAMAGED REPLACE VALVE REPLACE BACKFLUSH 8 X-40 RACK 25-56 VALVE 870406 16-1 052461 OPS FOR PCILRT NO FAILURE; TEST, CALIBRATE 140 VARIOUS CALIBRATE AND PUT IN SERVICE 870417 16-1 053496 JIC IMPROPER RTD-138B, 139B CORRECT WIRING; 15 RTD-138B INSTALLATION WIRED WRONG CHECK OPERATION 870414 17 050617 JIC SHOULD BE NO FAILURE; ADJUST SENSITIVITY 20 RM-251A-D WITHIN- ADJUST SENSITIVITY PSP-14 LIMITS 870407 17 050621 JIC P.M. MAKE SURE HANDLES- REMOVED PAINT; 8-RM-251A-D ARE GROUNDED CHECK CONTIN.

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT -

MAINTENANCE

SUMMARY

DOCKET NO: 50-333 UNIT NAME: FITZPATRICK DATE: May 7, 1987 COMPLETED BY: JOHN COOK-FOR THE MONTH OF: APRIL 1987 TELEPHONE: -(315).349-6569 WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TIME HOURS 870313 17 050720 JIC NO GROUND PATH LO ALARM WHEN CLEAR PAINT; REPAIR 11 RM-150A FOR PANEL, HANDLE- UNIT IS TOUCHED -CONNECTOR 870314 17 050721 JIC SENSITIVITY LOW READINGS DETERMINE NEW INPUT 16 RM-251A-D FACTORS NEED FOUND IN PSP-14 CURRENTS CHANGE 870408 20 053474 JIC NORMAL WEAR BLACK PEN BINDING; REPLACE BUSHINGS; 20 FR-528 BAD READING IMP-G14, ICS0-12 870115 23 036236 OPS MODIFICATION NO FAILURE; IMP-23.10 10 LS-90 M1-84-100 CALIBRATE NEW LEVEL SWITCH 870414 23 050616 JIC IMPROPER JUMPERS DID NOT OPERATE RESTORED JUMPERS 5 23A-K16 DURING ISP-125A 870414 23 052260 OPS DRIFT GAUGES NEED TO CALIBRATE PI-305, 4 GAUGES BE RECALIBRATED VAC CAUGE

4-NEW YORK POWER AUTHORITY-JAMES A. FITZPATRICK-NUCLEAR POWER PLANT, -

MAINTENANCE

SUMMARY

1 -

DOCKET NO:- 50-333-UNIT NAME: ' FITZPATRICK: , ' ' '

DATE: MAY.7.-1987

' COMPLETED BY: JOHN COOK FOR THE MONTH OF: ' APRIL 1987 TELEPHONE:

-(315)349-65691l WORK REQUEST NO. HOW CAUSE OF- RESULTS OF ACTION.TAKEN TO' .REPAIRI _

DATE SYSTEM COMPONENT NO. . DETECTED MALFUNCTION MALFUNCTION PRECLUDE' RECURRENCE TIME.

HOURS i

870401 23 052262 OPS DRIFT CALIBRATE VARIOUS CALIBRATE 20I GAUGES HPCI GAUGES' d

870413 23 052304 OPS P.M. NO FAILURE; . CALIBRATE GAUGES 26J TU-2 CHECK / CALIBRATE (REPLACE 303)

PRESSURE GAUGES

, 870407 23 053489 OPS DIAL OFF SPOT, TE-105A,' 114A REALIGN DIAL', REPAIR 1 6' TE-105A BAD CONNECTION INOPERABLE CONNECTION AT REC CH 8&9-j 870425 23 054227 OPS LOOSE SCREWS . SWITCH FELL OFF REINSTALL; CALIBRATE 7.5 PS-1 870410 27 025106 OPS MODIFICATION NO FAILURE; INSTALL, CALIBRATE 40 CAD PANEL F1-86-044 INSTALL NEW EQUIPMENT SEE ISCO-12 EQUIPMENT 870420 27 050639 JIC DRIFT METER DOWNSCALE CALIBRATE USING APPL '3 PCA-101A DURING ISP-30-1 STEPS 30-l' 1

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT -

~

MAINTENANCE

SUMMARY

DOCKET NO: 50-333 UNIT NAME: FITZPATRICK-DATE: MAY 7, 1987 COMPLETED BY: JOHN COOK.

FOR THE MONTH OF: APRIL 1987 TELEPHONE: ,

(315)'349-6569' WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION MALFUNCTION- PRECLUDE RECURRENCE TIME, j HOURS

~

870419 27 053382 OPS P.M. NO FAILURE; ISP-4-5 6 PT-101B PERFORM ISP-4-5 870404 27 053399 OPS P.M. NO FAILURE; CALIBRATE; 60 VARIOUS CALIBRATE LOOPS IMP-27.5 870404 66 046403 OPS WEAR ON-OFF CYCLP REPLACE; CALIBRATE 4 ACCU-2A PERIOD VERY SHORT IMP-G6-870420 66 051557 OPS WRONG VALVE OIL GAGUE NOT CORRECT. VALVES 5 ACCU-4A LINEUP WORKING 870423 66 051558 OPS BAD GAUGE; OIL GAUGE NOT REPLACE GAUGE, 14 ACCU-3A CLOSED ISOLATION WORKING OPEN VALVE VALVES 870418 66 051561 OPS ZERO NEEDED HI PRESSURE GAUGE CALIBRATE; ADJUST 8 ACCU-2B ADJUSTMENT NOT WORKING ZERO 870418 66 051639 OPS DAMPENING UNITS OIL PRESSURE GAUGE CLEAN UNITS 9 ACCU-3B DIRTY READING BAD

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT "

MAINTENANCE

SUMMARY

DOCKET NO: 50-333 UNIT NAME: FITZPATRICK-DATE: MAY 7. 1987 COMPLETED BY: JOHN COOK FOR THE MONTH OF: APRIL 1987 TELEPHONE: (315) 349-6569 -

WORK REQUEST NO. HOW CAUSE OF RESULTS OF ACTION TAKEN TO REPAIR DATE SYSTEM COMPONENT NO. DETECTED MALFUNCTION MALFUNCTION PRECLUDE RECURRENCE TIME HOURS 870411 66 051640 OPS GAUGE WAS OIL PRESSURE GAUGE REPALCE; CALIBRATE 6 ACCU-1B DAMAGED BAD .PER IMP-G1 870318 66 052438 JIC MODIFICATION NO FAILURE; INSTALLED PULSATION 26 ACCU'S 84-05 ECR #77 REPLACE DAMPENERS, .DAMPERNERS

~ TEST VALVES 870422 66 052501 OPS 1HCP2 TOO HIGH COMPRESS 0E COOLING CALIBRATE; CHECK 9 ACCU-3A FAN OUT OF OPERATION CALIBRATION 870402 66 053479 JIC WEAR CONTACE 4 WON'T ' REPLACE SWITCH; WRITE 4 ACCU-3 RESET WIRE MOD 84-005 87023 66 054166 OPS DRIFT OPDI (PSID) READS IMP-G1 10 ACCU-1B DOWNSCALE 870416 71 052467 OPS MODIFICATION NO FAILURE; ISP-90-1; 20 RELAYS F1-84-041 CALIBRATE ISP-91-1

  1. , y . +s- ,

NEW.. YORK; POWER AUTHORITY' -

JAMES A. FITZPATRICK NUCLEAR POWER' PLANT: ,- ,'

  • _ MAINTENANCE

SUMMARY

DOCKET NO: 50-333 UNIT NAME:"< FITZPATRICK DATE: MAY.7.-1987:

COMPLETED'BY: ~ JOHN COOK FOR THE., MONTH OF:. APRIL 1987- . TELEPHONE: .(315);349--6569 WORK REQUEST NO. HOW .CAUSE OF' RESULTS OF- -ACT5dNTAKENTO. -REPAIR' DATE. SYSTEM COMPONENT NO. DETECTED MALFUNCTION . MALFUNCTION PRECLUDE RECURRENCE ~T  : TIME 1 HOURS 870418 76 054113 OPS DIGITAL AUTO MPX #5 HAS REPLACE' 5:

MPX #5 X-0VER UNIT BAD FAILED 870402 87 053602 OPS PROBLEM IN A BOILER WILL . TROUBLESHOOT IGNITER '20 A BOILER IGNITER NOT FIRE PROBLEM 870409 93 051977 OPS OIL PRESSURE GAUGE CHECK CALIBRATION PERFORM IMP-G1;. 8 PI-4B READS UNUSUALLY. OF LUBE OIL CHECKED OK LOW PRESSURE 870421 93 054151 OPS METER BOUND UP KILOWATT METER DISASSEMBLE, ADJUST, 8 KW-1B AT LOW END FAILED IN ST-9C RETURN 870420 94 054160 OPS BAD CHART DRIVE RECORDER WON'T REPLACE FROM STOCK 10 94-VR ' MOTOR WORK FAST SPEED-

- NEWJORK POWER AUIHORITY JAMES A.. FITZ'ATRICK r NUCLEAR POWER PLANT '

SAFEIY RELATED FTECTRICAL & MECHANICAL MAINIENANCE SlWARY APRIL 1987 REPAIR klORK REQUEST f TIME DATE SYSTEM CWPONENT HOR Dnuatu CAUSE OF MALFUNCTION ACTION TAKEN 'IO PRECLUDE RECURRENCE HOURS 4/1 03 53548 OPS Worn piston Replaced accmulator 10 H T 22-31


__ --------------- __=_----------------------------------------- === .

4/4 02-2 53402 URT Seat leaks Overhauled valves 20 RWR T3A & B 4/4 23 52991 URT Seat leaks Overhauled valve 85 HPT 55


.-- -----------------------_=- .=_= =====____ __

4/6 23 53788 LIRT Seat leaks Overhauled valve 11 HPT 402

__--____----------___-----__---------_--_------_ -------_------_--___----------------------_-__--_------------==-_ ==---_----.

4/6 23 53787 LIRT Seat leaks Overhauled valve 13 HPI E03


- .-------------------------------------------------- . .=---------- -----------------------------.

4/1 10 42461 OPS Worn packing Replaced packing 0 FDV-70B 4/1 10 52639 ILRT Seat leaks Overhauled valve 15 FDV 39B 4/2 03 46432 OPS Reed switch failure Replaced PI probe 3

' CRIT IO-39

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - = - - - - _ = = = - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4/2 03 45483 OPS Thermocouple failure Replaced PI probe O CRD 22-27 F 2II-4/'/- 02 53612 OPS Seat leaks Overhauled valve 65 XDT T7 & 18 4/18 29 53922 OPS Worn seals Rebuilt air operator 83 AOV-80C & D

NER YORK POWER AUIHORITY JAMES A. FITZPATRICK NUCTFAR 10WER PIANI -

SAFETY RELATED ELECTRICAL & MECHANICAL MAINTENANCE SUbHARY APRIL 1987 REPAIR KORK REQUEST f TIFE DATE SYSTIN CCEPONENT HOR DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE HOURS 4/18 27 54143 Hydro Weld leaks Repaired welds 0 NV 9X 4/18 27 53353 Hydro Weld leaks Repaired welds 0 NV 9H 4/16 23 54063 OPS Bent handwheel shaft Repaired operator 0 FDV 25 4/2 23 50969 OPS Bent handwheel shaft Repaired operator 13 FDV T7

_____________ =____________________________________________________________________________________________________________

4/19 24 53852 OPS Burned out coil Replaced coil 0 EDD- T & 2 4/15 13 53072 OPS Manual operator broken Overhauled operator 0 FDV I6 4/21 29 54172 OPS Worn seals Rebuilt air cylinder 18 XDV H6B 4/5 29 51560 OPS Worn packing Replaced packing 12 FST T20 4/5 10 53979 LLRT Worn seats Overhauled valve 60.5 FDV 18B 4/13 27 18228 OPS Worn seats Overhauled valve 26 FCV IO3A 4/13 10 51556 LLRT Worn seats Overhauled valve 101 FDV 14B 4/20 29 52182 OPS Worn seals Overhauled hydraulic cylinder 265.5 IDV 50C

NEW YORK POWER AUIHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT '

SAFEIY REIATED ELECTRICAL & MECHANICAL MAINTENANCE SRt4ARY APRIL 1987 REPAIR WRK REQUEST f TIME DATE SYSTDi CQ4PONENT HOR DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE HOURS 4/1 10 51597 OPS Wom spring pack Overhauled limitorque 0 FDV 70B 4/5 10 53086 OPS Worn clutch Overhauled limitorque 20.5 FDVU8B 4/1 29 51642 PM GLS Rotor cracked Overhauled limitorque 0 FDV 74

4 NEW YORK POWER AUIHORITY JAMES A. FITZPATRICK NUCLEAR POWER PIRT. .

SAFELY REIATED FJFCIRICAL & MECHANICAL MAINTENANCE SIM4ARY APRIL 1987 REPAIR KORK REQUEST f TINE DATE SYSTD4 C W PONENI' HOR DEI'ECTED CAUSE OF MALFUNCTION ACTION TAKEN'IO PRECLUDE RECURRENCE HOURS 4/1 03 53548 OPS Worn piston Replaced accuculator HCU 22-31 4/4 02-2 53402 LLRT Seat leaks Overhauled valves R W I3A & B 4/4 23 52991 LLRT Seat leaks Overhauled valve HPT 65 4/6 23 53788 LLRT Seat leaks Overhauled valve HPT E02 4/6 23 53787 LLRT Seat leaks Overhauled valve HPT~E03 FDV 70B FDV_19B 4/2 03 46432 OPS Reed switch failure Replaced PI probe CRD 10-39 4/2 03 45483 OPS 'Ihermocouple failure Replaced PI probe CRD 22-27 F 2B-4/14 02 53612 OPS Seat leaks Overhauled valve IDV T7 & 18 4/18 29 53922 OPS Worn seals Rebuilt air operator ZDV-HOC & D

NEW 'iORK POWER AUIEORITY .

JAMES A. FITZPATRICK NUCLEAR POWER PLANT

  • EAFETY RELATED ELECTRICAL & MECHANICAL MAINTENANCE SIM4ARY -

APRIL 1987 REPAIR kORK REQUEST # TIME DATE SYSTDi CWPONENT HOW DEFECTED CAUSE OF MAIENCTION ACTION TAKEN 'IO PRECLUDE RECURRENCE HOURS 4/18 27 54143 Hydro Weld leaks Repaired welds E7~9X

___________________________= -_===____________________________________________________________________________________________

4/18 27 53353 Hydro Weld leaks Repaired welds EV~91i 4/16 23 54063 OPS Bent handwheel shaft Repaired operator FDV 25 4/2 23 50969 OPS Bent handwheel shaft Repaired operator FOV-17

________________________. .====__________________________ __. _______________________________________________________________

4/19 24 53852 OPS Burned out coil Replaced coil EDD I & 2

___________________________________________________________=. ________________________________________________________________

4/15 13 53072 OPS Manual operator broken Overhauled operator FDV I6 4/21 29 54172 OPS Worn seals Rebuilt air cylinder ZDV-36B 4/5 29 51560 OPS Worn packirg Replaced packing MT 120 4/5 10 53979 LLRT Worn seats Overhauled valve FDV-38B 4/13 27 18228 OPS Worn seats Overhauled valve TCV I03A 4/13 10 51556 LLRT Worn seats Overhauled valve FDV 34B 4/20 29 52182 OPS Worn seals Overhauled hydraulic cylinder ZDV 80C

~

NEW YORK POWER AUIHORITY '

JAMES A. FITZoATRICK hV3FAR PCXER PLANT .

SAFETY RELATED ELECTRICAL & MECHANICAL MAINIENANCE SG14ARY APRIL 1987 REPAIR M)RK REQUEST f TIME DATE SYSTEM C04PONENT HOW DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE HOURS 4/1 10 51597 OPS Worn spring pack Overhauled limitorque FDV 70B 4/5 10 53086 OPS Wom clutch Overhauled limitorque FDV'J8B


____ _=------_---------------------------_---------------_---------------------------------------------------.

4/1 29 51642 PM GLS Rotor cracked Overhauled limitorque FDV 74 9

C, .?.

. James A. Fit: Patrick Cu Jear Power Plant Po. Box 41 Lycoming. New York 13093 315 342.3840 Radford J. Converse

  1. > NewYorkPbwer

& Authority May 8, 1987 JAFP-87-0393 Director, Office of Inspection and Enforcement U.S. Nucl ear Regulatory Comr.ii ss ion Washington, D.C. 20555 ATTENTION: DOCUMENT CONTROL DESK

REFERENCE:

DOCKET NO. 50-333

Dear Sir:

Enclosed please find the J. A. FitzPatrick Operating Status Report for the month of AprII, 1987.

Refueling Information is being collected and will be transmitted with next months submittal.

If there are any questions concerning this report, please con act John Cook at (315) 349-6569.

W-ADFORD d. CONVERSE RESIDENT MANAGER RdC:dPC:mac Enclosures cc: Distribution t