Text

...

LW U.S. NUCLEAR REGULATORY COMMISSION

REGION III

Report No. 72-1/93001(DRSS)

Docket No. 72-1 License No. SNM-2500 Safeguards Group II Licensee: General Electric Company 7555 E. Collins Rd.

Morris, IL 60450 Facility Name:

General Electric Company, Morris Operation Inspection At:

Morris Operation, Morris, Illinois Inspection Conducted:

June 2-3, 1993 Type of Inspection: Announced Material Control and Accountability (MC&A)

Date of Last MC&A Inspection: December 15-16, 1986 0bIV

.

Inspector: IS

J. R. Kniceley J

Date Physical Security Inspector Approved By:

-

'b

.

f./R. Creed, Chief Date 6feguards Section Inspection Summary Inspection on June 2-3. 1993 (Recort No. 72-1/93001(DRSS))

Areas Inspected:

Special Nuclear Material Control and Accoun ability Inspection, including possession, use, and accounting of SNM. This included a review of Facility Organization and Operation; Measurement and Statistical Controls; Shipping and Receiving; Storage and Internal Controls; and Inventory Records and Reports.

Results: The licensee was found to be in compliance with NRC requirements in the areas examined.

The licensee has implemented an adequate and effective program to account for and control SNM in their possession.

0IP

?IOR UPC'I E7JP' * Jus THIS PF4 IS D./

.TEOLLED 9306160068 930609 PDR ADOCK 07200001 C

PDR