9-

.

.

U.S.-NUCLEAR REGULATORY COMMISSION

REGION III

_.

^

Report No. 50-461/88019(DRSS).

Docket No. 50-461 License No. NPF-55 Licensee:

Illinois Power company 500 South 27th-Street

'

Decatur, IL 62525 Facility Name:

Clinton Pover Station, Clinton, Illinois Inspection At:

Clinton Poiver Station Inspection Conducted:

Ju',y 25-29,1988 Type of Inspection:

Unannounced Physical Security Inspection

G rw.4 b cti /cr7 8- //- 8T Inspector:

B. )redin B

Date

Physical Security Inspector i

(bh OM8 Approved By:

'

gSafeguardsSection

. R. Creed, Chief Date'

Inspection Summary Inspection on July 25-29, 1988 (Report No. 50-461/88019(DRSS))

Areas Inspected:

Management Effectiveness; Security Organization; Records and Reports; Testing and Maintenance; Locks, Keys and Combinations; Compensatory Measure; Assessment Aids; Access Control - Personnel,-Packages and Vehicles;-

Detection Aids - Protected Area; Communications; Personnel Training and Qualifications; Safeguards Contingency Plan; Protection of Safeguards Information and Licensee action on previous findings.

Resu'i ts:

The licensee was determined to be in compliance with NRC requirements I

in all 15 inspected areas.

Two prev aus inspection findings were closed.

In the one remaining open item the liceisec is achieving acceptable progress in reducing their alarm rate.

One allegation involving the innproper storage of safeguards information was not substantiated.

The licensee's security management team is effective and plans well.

Security personnel are very knowledgeable of their duties and responsibilities.

Inclosure contains SAFEGUAPDS INFORMATION h!k bbCk O

Opon separation this O

PNU page is Decontrolled I

, ~

+

v v

+-m

- -.

,-w

-

,